Sample records for syringe exchange programmes

  1. Tuberculosis knowledge among injecting drug users visiting syringe exchange programme in Tallinn, Estonia.

    PubMed

    Rüütel, Kristi; Parker, R David; Sobolev, Igor; Loit, Helle-Mai

    2012-12-01

    The purpose of the current study was to describe tuberculosis (TB) knowledge, beliefs, and experience with TB services among injecting drug users. Participants for this anonymous, cross-sectional study were recruited from a community based syringe exchange programme in Tallinn, Estonia. A structured questionnaire was completed and included information on socio-demographics, health history, drug use, and knowledge about TB and HIV. The study included 407 people (79% male, mean age 27.9 years, mean injection drug use 9.4 years). 32.9% of participants reported HIV infection and 1.7% lifetime history of TB. 26.4% participants (n=106) reported symptoms suggestive of TB. 93% of participants recognized correctly that TB is air-borne infection and 91% that HIV is a risk factor for TB. Only 40% of the participants knew that TB diagnostics and treatment in Estonia are free of charge for everybody and 58% reported they knew where to get health care services in case they suspected that they had TB. TB transmission and treatment adherence knowledge was better among those in contact with either health care or harm reduction services, e.g the community based syringe exchange programme. Similar to HIV services, TB prevention and education should be integrated into harm reduction and drug treatment programmes to facilitate early diagnosis and treatment of TB among injecting drug users.

  2. Correlates of syringe coverage for heroin injection in 35 large metropolitan areas in the US in which heroin is the dominant injected drug

    PubMed Central

    Tempalski, Barbara; Cooper, Hannah L.; Friedman, Samuel R.; Des Jarlais, Don C.; Brady, Joanne; Gostnell, Karla

    2009-01-01

    Background Scientific consensus holds that if, at the outset of the HIV/AIDS epidemic, injection drug users (IDUs) had had better access to sterile syringes, much of the epidemic among IDUs in the U.S. could have been prevented. In the context of preventing infectious diseases, 100% syringe coverage—that is, one sterile syringe per injector for each injection—is a public health goal. Notably, we know little about variations in syringe coverage within the U.S. and elsewhere, or about the social and political factors that might determine this coverage. Methods Using data from Holmberg (AJPH, 1996), the 1990 United States Census, the 2000 Beth Israel National Syringe Exchange Survey (n=72), and estimates of IDUs in metropolitan areas (MSAs); (Friedman et al., 2004), we explore the impact of (1) political factors (ACT UP, outreach, early syringe exchange programme (SEP) presence, men who have sex with men (MSM) per capita, drug arrests, and police per capita); (2) local resources for SEPs; and (3) indicators of socioeconomic inequality on SEP coverage. We define “syringe coverage” as the ratio of syringes distributed at SEPs to the number of syringes heroin injectors need in a year. We calculated the number of syringes heroin injectors need in a year by multiplying an estimate of the number of IDUs in each MSA by an estimate of the average number of times heroin injectors inject heroin per year (2.8 times per day times 365 days). In this analysis, the sample was limited to 35 MSAs in which the primary drug of choice among injectors was heroin. Results SEP coverage varies greatly across MSAs, with an average of 3 syringes distributed per 100 injection events (std dev = 0.045; range: 2 syringes per 10 injection events, to 3 syringes per 10,000 injection events). In bivariate regression analyses, a 1 unit difference in the proportion of the population that was MSM per 1,000 was associated with a difference of 0.002 in SEP coverage (p=0.052); early SEP presence was associated with a difference of 0.038 in coverage (p=0.012); and having government funding was associated with a 0.040 difference in SEP coverage (p=0.021). Conclusions This analysis suggests that longer duration of SEP presence may increase syringe distribution and enhance successful programme utilization. Furthermore, MSAs with greater proportions of MSM tend to have better SEP coverage, perhaps providing further evidence that grassroots activism plays an important role in programme implementation and successful SEP coverage. This research provides evidence that government funding for SEPs contributes to better syringe coverage. PMID:18295468

  3. Drug residues in used syringes in Switzerland: A comparative study.

    PubMed

    Lefrançois, Elodie; Augsburger, Marc; Esseiva, Pierre

    2018-05-01

    Harm reduction services, including needle-exchange programmes, have been implemented in Switzerland for over 20 years. Their main aim is to lessen the negative social and/or physical consequences associated with illicit drug consumption and, therefore, improve prevention messages. To this end, knowledge of illicit drug consumption practices is necessary. Periodic self-report surveys are the primary source of data for monitoring drug users' behaviour. Analysis of residual content of used syringes can bring further and objective knowledge about consumed products through analytically confirmed data. Used syringes were sampled in 2 syringe-exchange facilities in Lausanne. These structures are a bus where the users bring back their syringes (ABS) and an automatic injecting kit dispenser (AIKD). Once syringes were collected, a validated gas chromatography-mass spectrometry (GC-MS) method was implemented in order to detect drugs (licit or illicit) contained in the residual content of used syringes. Cocaine was the most common drug detected alone (39% in ABS and 31% in AIKD), followed by the simultaneous detection of heroin and cocaine (12% and 17%) and heroin and midazolam (12% and 17%). The differences between the illicit drugs distribution of used syringes collected in AIKD and ABS were not statistically significant. Analysis of residual content of used syringes as a monitoring tool is an original approach that has already led to a better understanding of the habits of drug-injection users. Over the long term, this approach is a powerful tool to track and detect new consumption practices in a quasi-real-time. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Integrating multiple programme and policy approaches to hepatitis C prevention and care for injection drug users: a comprehensive approach.

    PubMed

    Birkhead, Guthrie S; Klein, Susan J; Candelas, Alma R; O'Connell, Daniel A; Rothman, Jeffrey R; Feldman, Ira S; Tsui, Dennis S; Cotroneo, Richard A; Flanigan, Colleen A

    2007-10-01

    New York State is home to an estimated 230,000 individuals chronically infected with hepatitis C virus (HCV) and roughly 171,500 active injection drug users (IDUs). HCV/HIV co-infection is common and models of service delivery that effectively meet IDUs' needs are required. A HCV strategic plan has stressed integration. HCV prevention and care are integrated within health and human service settings, including HIV/AIDS organisations and drug treatment programmes. Other measures that support comprehensive HCV services for IDUs include reimbursement, clinical guidelines, training and HCV prevention education. Community and provider collaborations inform programme and policy development. IDUs access 5 million syringes annually through harm reduction/syringe exchange programmes (SEPs) and a statewide syringe access programme. Declines in HCV prevalence amongst IDUs in New York City coincided with improved syringe availability. New models of care successfully link IDUs at SEPs and in drug treatment to health care. Over 7000 Medicaid recipients with HCV/HIV co-infection had health care encounters related to their HCV in a 12-month period and 10,547 claims for HCV-related medications were paid. The success rate of transitional case management referrals to drug treatment is over 90%. Training and clinical guidelines promote provider knowledge about HCV and contribute to quality HCV care for IDUs. Chart reviews of 2570 patients with HIV in 2004 documented HCV status 97.4% of the time, overall, in various settings. New HCV surveillance systems are operational. Despite this progress, significant challenges remain. A comprehensive, public health approach, using multiple strategies across systems and mobilizing multiple sectors, can enhance IDUs access to HCV prevention and care. A holisitic approach with integrated services, including for HCV-HIV co-infected IDUs is needed. Leadership, collaboration and resources are essential.

  5. Consequences of a restrictive syringe exchange policy on utilization patterns of a syringe exchange program in Baltimore, Maryland: Implications for HIV risk

    PubMed Central

    Sherman, Susan G.; Patel, Shivani A.; Ramachandran, Daesha V.; Galai, Noya; Chaulk, Patrick; Serio-Chapman, Chris; Gindi, Renee M.

    2016-01-01

    Background Syringe distribution policies continue to be debated in many jurisdictions throughout the U.S. The Baltimore Needle and Syringe Exchange Program (NSP) operated under a 1-for-1 syringe exchange policy from its inception in 1994 through 1999, when it implemented a restrictive policy (2000–2004) that dictated less than 1-for-1 exchange for non-program syringes. Methods Data were derived from the Baltimore NSP, which prospectively collected data on all client visits. We examined the impact of this restrictive policy on program-level output measures (i.e., distributed:returned syringe ratio, client volume) before, during, and after the restrictive exchange policy. Through multiple logistic regression, we examined correlates of less than 1-for-1 exchange ratios at the client-level before and during the restrictive exchange policy periods. Results During the restrictive policy period, the average annual program-level ratio of total syringes distributed:returned dropped from 0.99 to 0.88, with a low point of 0.85 in 2000. There were substantial decreases in the average number of syringes distributed, syringes returned, the total number of clients, and new clients enrolling during the restrictive compared to the preceding period. During the restrictive period, 33,508 more syringes were returned to the needle exchange than were distributed. In the presence of other variables, correlates of less than 1-for-1 exchange ratio were being white, female, and less than 30 years old. Discussion With fewer clean syringes in circulation, restrictive policies could increase the risk of exposure to HIV among IDUs and the broader community. The study provides evidence to the potentially harmful effects of such policies. PMID:25919590

  6. Syringe Exchange, Injecting and Intranasal Drug Use

    PubMed Central

    Arasteh, Kamyar; McKnight, Courtney; Ringer, Martin; Friedman, Samuel R.

    2016-01-01

    Objective To assess trends in injecting and non-injecting drug use after implementation of large-scale syringe exchange in New York City. The belief that implementation of syringe exchange will lead to increased drug injecting has been a persistent argument against syringe exchange. Methods Administrative data on route of administration for primary drug of abuse among patients entering the Beth Israel methadone maintenance program from 1995 – 2007. Approximately 2000 patients enter the program each year. Results During and after the period of large scale implementation of syringe exchange, the numbers of methadone program entrants reporting injecting drug use decreased while the numbers of entrants reporting intranasal drug use increased (p < .001). Conclusion While assessing possible effects of syringe exchange on trends in injecting drug use is inherently difficult, this may be the strongest data collected to date showing a lack of increase in drug injecting following implementation of syringe exchange. PMID:19891668

  7. Decreased Odds of Injection Risk Behavior Associated With Direct Versus Indirect Use of Syringe Exchange: Evidence From Two California Cities.

    PubMed

    Behrends, Czarina N; Li, Chin-Shang; Gibson, David R

    2017-07-29

    While there is substantial evidence that syringe exchange programs (SEPs) are effective in preventing HIV among people who inject drugs (PWID), nearly all the evidence comes from PWID who obtain syringes from an SEP directly. Much less is known about the benefits of secondary exchange to PWID who get syringes indirectly from friends or acquaintances who visit an SEP for them. We evaluated the effectiveness of direct versus indirect syringe exchange in reducing HIV-related high-risk injecting behavior among PWID in two separate studies conducted in Sacramento and San Jose, California, cities with quite different syringe exchange models. In both studies associations between direct and indirect syringe exchange and self-reported risk behavior were examined with multivariable logistic regression models. Study 1 assessed effects of a "satellite" home-delivery syringe exchange in Sacramento, while Study 2 evaluated a conventional fixed-site exchange in San Jose. Multivariable analyses revealed 95% and 69% reductions, respectively, in high-risk injection associated with direct use of the SEPs in Sacramento and San Jose, and a 46% reduction associated with indirect use of the SEP in Sacramento. Conclusions/Importance: The very large effect of direct SEP use in Sacramento was likely due in part to home delivery of sterile syringes. While more modest effects were associated with indirect use, such use nevertheless is valuable in reducing the risk of HIV transmission of PWID who are unable or unwilling to visit a syringe exchange.

  8. Epinephrine syringe exchange events in a paediatric cardiovascular ICU: analysing the storm.

    PubMed

    Achuff, Barbara-Jo; Achuff, Jameson C; Park, Hwan H; Moffett, Brady; Acosta, Sebastian; Rusin, Craig G; Checchia, Paul A

    2018-03-01

    Introduction Haemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control). Materials and methods Beat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children's Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data. In all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (p<0.001), duration (p<0.001), and amplitude (p<0.001) compared with control data. This novel data collection and signal processing analysis showed a significant increase in frequency, duration, and magnitude of systolic blood pressure perturbations surrounding epinephrine syringe exchange events.

  9. Introducing auto-disable syringes to the national immunization programme in Madagascar.

    PubMed Central

    Drain, Paul K.; Ralaivao, Josoa S.; Rakotonandrasana, Alexander; Carnell, Mary A.

    2003-01-01

    OBJECTIVE: To evaluate the safety and coverage benefits of auto-disable (AD) syringes, weighed against the financial and logis- tical costs, and to create appropriate health policies in Madagascar. METHODS: Fifteen clinics in Madagascar, trained to use AD syringes, were randomized to implement an AD syringe only, mixed (AD syringes used only on non-routine immunization days), or sterilizable syringe only (control) programme. During a five-week period, data on administered vaccinations were collected, interviews were conducted, and observations were recorded. FINDINGS: The use of AD syringes improved coverage rates by significantly increasing the percentage of vaccines administered on non-routine immunization days (AD-only 4.3%, mixed 5.7%, control 1.1% (P<0.05)). AD-only clinics eliminated sterilization sessions for vaccinations, whereas mixed clinics reduced the number of sterilization sessions by 64%. AD syringes were five times more expensive than sterilizable syringes, which increased AD-only and mixed clinics' projected annual injection costs by 365% and 22%, respectively. However, introducing AD syringes for all vaccinations would only increase the national immunization budget by 2%. CONCLUSION: The use of AD syringes improved vaccination coverage rates by providing ready-to-use sterile syringes on non-routine immunization days and decreasing the number of sterilization sessions, thereby improving injection safety. The mixed programme was the most beneficial approach to phasing in AD syringes and diminishing logistical complications, and it had minimal costs. AD syringes, although more expensive, can feasibly be introduced into a developing country's immunization programme to improve vaccination safety and coverage. PMID:14576886

  10. The Washington Needle Depot: fitting healthcare to injection drug users rather than injection drug users to healthcare: moving from a syringe exchange to syringe distribution model

    PubMed Central

    2010-01-01

    Needle exchange programs chase political as well as epidemiological dragons, carrying within them both implicit moral and political goals. In the exchange model of syringe distribution, injection drug users (IDUs) must provide used needles in order to receive new needles. Distribution and retrieval are co-existent in the exchange model. Likewise, limitations on how many needles can be received at a time compel addicts to have multiple points of contact with professionals where the virtues of treatment and detox are impressed upon them. The centre of gravity for syringe distribution programs needs to shift from needle exchange to needle distribution, which provides unlimited access to syringes. This paper provides a case study of the Washington Needle Depot, a program operating under the syringe distribution model, showing that the distribution and retrieval of syringes can be separated with effective results. Further, the experience of IDUs is utilized, through paid employment, to provide a vulnerable population of people with clean syringes to prevent HIV and HCV. PMID:20047690

  11. The syringe gap: an assessment of sterile syringe need and acquisition among syringe exchange program participants in New York City

    PubMed Central

    Heller, Daliah I; Paone, Denise; Siegler, Anne; Karpati, Adam

    2009-01-01

    Background Programmatic data from New York City syringe exchange programs suggest that many clients visit the programs infrequently and take few syringes per transaction, while separate survey data from individuals using these programs indicate that frequent injecting – at least daily – is common. Together, these data suggest a possible "syringe gap" between the number of injections performed by users and the number of syringes they are receiving from programs for those injections. Methods We surveyed a convenience sample of 478 injecting drug users in New York City at syringe exchange programs to determine whether program syringe coverage was adequate to support safer injecting practices in this group. Results Respondents reported injecting a median of 60 times per month, visiting the syringe exchange program a median of 4 times per month, and obtaining a median of 10 syringes per transaction; more than one in four reported reusing syringes. Fifty-four percent of participants reported receiving fewer syringes than their number of injections per month. Receiving an inadequate number of syringes was more frequently reported by younger and homeless injectors, and by those who reported public injecting in the past month. Conclusion To improve syringe coverage and reduce syringe sharing, programs should target younger and homeless drug users, adopt non-restrictive syringe uptake policies, and establish better relationships with law enforcement and homeless services. The potential for safe injecting facilities should be explored, to address the prevalence of public injecting and resolve the 'syringe gap' for injecting drug users. PMID:19138414

  12. Factors associated with buying and selling syringes among injection drug users in a setting of one of North America's largest syringe exchange programs.

    PubMed

    Kuyper, Laura M; Kerr, Thomas; Li, Kathy; Hogg, Robert S; Tyndall, Mark W; Montaner, Julio S G; Wood, Evan

    2006-01-01

    We performed analyses of syringe buying and syringe selling among Vancouver injection drug users, recruited from May 1996 and followed up between November 2002 and August 2003, in the context of one of North America's largest syringe exchange programs (SEPs). An interviewer-administered questionnaire, approximately 45 minutes in duration, was used to collect information regarding risk factors for HIV infection and sources of sterile syringes. Seventy participants (15%) reported syringe selling and 122 (26%) reported syringe buying. Syringe sellers were more likely to be female, reside in unstable housing, need help injecting, and have visited the SEP at least once weekly. Syringe buyers were more likely to need help injecting, have difficulty finding new syringes, have binged on drugs, and have visited the SEP at least once weekly. Syringe buying most frequently occurred when the SEP was closed.

  13. Exploring stakeholder perceptions of acceptability and feasibility of needle exchange programmes, syringe vending machines and safer injection facilities in Tijuana, Mexico.

    PubMed

    Philbin, Morgan M; Mantsios, Andrea; Lozada, Remedios; Case, Patricia; Pollini, Robin A; Alvelais, Jorge; Latkin, Carl A; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2009-07-01

    Injection drug use is a growing public health crisis along the U.S.-Mexican border and rising rates of blood-borne infections highlight the pressing need for harm reduction interventions. We explored the acceptability and feasibility of such interventions in Tijuana, a city adjacent to San Diego, California. Using in-depth qualitative interviews conducted from August 2006-March 2007 with 40 key stakeholders - pharmacists, legal professionals, health officials, religious officials, drug treatment providers, and law enforcement personnel - we explored the acceptability and feasibility of interventions to reduce drug-related harm in Tijuana, Mexico. Interviews were taped with consent, transcribed verbatim, and translated. Content analysis was conducted to identify themes which included barriers, structural limitations, and suggestions for implementation. Topics included acceptance and feasibility of needle exchange programmes (NEPs), syringe vending machines, and safer injection facilities (SIFs), structural barriers and suggestions for implementation. Of these interventions, NEPs were deemed the most acceptable (75%); however, only half believed these could be feasibly implemented, citing barriers involving religion, police, and lack of political will, public awareness, and funding. Increasing HIV infection rates among injection drug users in Tijuana have prompted interest in public health responses. Our results may assist policy strategists in implementing social-structural interventions that will help create enabling environments that facilitate the scale-up and implementation of harm reduction in Tijuana.

  14. The effectiveness and safety of syringe vending machines as a component of needle syringe programmes in community settings.

    PubMed

    Islam, Mofizul; Wodak, Alex; Conigrave, Katherine M

    2008-12-01

    Syringe vending machines (SVMs) have been introduced in Europe and Australasia as part of the effort to increase the availability of sterile needles and syringes to injecting drug users (IDUs). This qualitative review of 14 published and grey literature studies examines whether community-based SVMs as a component of a comprehensive needle syringe programme (NSP) assist to reduce the spread of HIV and other blood-borne viruses amongst IDUs. The available evidence suggests that SVMs increase access to sterile injecting equipment, reduce needle and syringe sharing, and are likely to be cost efficient. SVMs also complement other modes of NSP delivery as they are used by IDUs who are less likely to attend staffed NSPs or pharmacies. If installed and properly maintained in a well-chosen location and with the local community well prepared, SVMs can enhance the temporal and geographical availability of sterile injecting equipment.

  15. Exploring stakeholder perceptions of acceptability and feasibility of needle exchange programmes, syringe vending machines and safer injection facilities in Tijuana, Mexico

    PubMed Central

    Philbin, Morgan M.; Mantsios, Andrea; Lozada, Remedios; Case, Patricia; Pollini, Robin A.; Alvelais, Jorge; Latkin, Carl A.; Magis-Rodriguez, Carlos; Strathdee, Steffanie A.

    2009-01-01

    Background Injection drug use is a growing public health crisis along the U.S.–Mexican border and rising rates of blood-borne infections highlight the pressing need for harm reduction interventions. We explored the acceptability and feasibility of such interventions in Tijuana, a city adjacent to San Diego, California. Methods Using in-depth qualitative interviews conducted from August 2006–March 2007 with 40 key stakeholders – pharmacists, legal professionals, health officials, religious officials, drug treatment providers, and law enforcement personnel – we explored the acceptability and feasibility of interventions to reduce drug-related harm in Tijuana, Mexico. Interviews were taped with consent, transcribed verbatim, and translated. Content analysis was conducted to identify themes which included barriers, structural limitations, and suggestions for implementation. Results Topics included acceptance and feasibility of needle exchange programmes (NEPs), syringe vending machines, and safer injection facilities (SIFs), structural barriers and suggestions for implementation. Of these interventions, NEPs were deemed the most acceptable (75%); however, only half believed these could be feasibly implemented, citing barriers involving religion, police, and lack of political will, public awareness, and funding. Conclusions Increasing HIV infection rates among injection drug users in Tijuana have prompted interest in public health responses. Our results may assist policy strategists in implementing social-structural interventions that will help create enabling environments that facilitate the scale-up and implementation of harm reduction in Tijuana. PMID:18963906

  16. Sharing of Needles and Syringes among Men Who Inject Drugs: HIV Risk in Northwest Bangladesh.

    PubMed

    Pasa, M Kamal; Alom, Kazi Robiul; Bashri, Zubaida; Vermund, Sten H

    2016-01-01

    Injection drug use is prevalent in northwestern Bangladesh. We sought to explore the context of needle/syringe sharing among persons who inject drugs (PWID), examining risk exposures to blood-borne infections like the human immunodeficiency virus (HIV) and hepatitis in a region where these dual epidemics are likely to expand. We used a qualitative research approach to learn about injection practices, conducting 60 in-depth interviews among PWID. We then conducted 12 focus group discussions (FGDs) that generated a checklist of salient issues, and followed up with personal observations of typical days at the drug-use venues. Content and interpretative frameworks were used to analyze qualitative information and socio-demographic information, using SPSS software. We found that needle/syringe-sharing behaviours were integrated into the overall social and cultural lives of drug users. Sharing behaviours were an central component of PWID social organization. Sharing was perceived as an inherent element within reciprocal relationships, and sharing was tied to beliefs about drug effects, economic adversity, and harassment due to their drug user status. Carrying used needles/syringes to drug-use venues was deemed essential since user-unfriendly needle-syringe distribution schedules of harm reduction programmes made it difficult to access clean needles/syringes in off-hours. PWID had low self-esteem. Unequal power relationships were reported between the field workers of harm reduction programmes and PWID. Field workers expressed anti-PWID bias and judgmental attitudes, and also had had misconceptions about HIV and hepatitis transmission. PWID were especially disturbed that no assistance was forthcoming from risk reduction programme staff when drug users manifested withdrawal symptoms. Interventions must take social context into account when scaling up programmes in diverse settings. The social organization of PWID include values that foster needle-syringe sharing. Utilization and impact of risk reduction programmes might be improved with expanded clean needle/syringe distribution at times and venues convenient for PWID, better trained and non-judgmental staff, and medical assistance for health problems, including drug withdrawal symptoms.

  17. Hypertensive Crisis During Norepinephrine Syringe Exchange: A Case Report.

    PubMed

    Snijder, Roland A; Knape, Johannes T A; Egberts, Toine C G; Timmerman, Annemoon M D E

    2017-04-01

    A 67-year critically ill patient suffered from a hypertensive crisis (200 mm Hg) because of a norepinephrine overdose. The overdose occurred when the clinician exchanged an almost-empty syringe and the syringe pump repeatedly reported an error. We hypothesized that an object between the plunger and the syringe driver may have caused the exertion of too much force on the syringe. Testing this hypothesis in vitro showed significant peak dosing errors (up to +572%) but moderate overdose (0.07 mL, +225%) if a clamp was used on the intravenous infusion line and a large overdose (0.8 mL, +2700%) if no clamp was used. Clamping and awareness are advised.

  18. Syringe Disposal Among Injection Drug Users in San Francisco

    PubMed Central

    Martinez, Alexis N.; Carpenter, Lisa; Geckeler, Dara; Colfax, Grant; Kral, Alex H.

    2011-01-01

    To assess the prevalence of improperly discarded syringes and to examine syringe disposal practices of injection drug users (IDUs) in San Francisco, we visually inspected 1000 random city blocks and conducted a survey of 602 IDUs. We found 20 syringes on the streets we inspected. IDUs reported disposing of 13% of syringes improperly. In multivariate analysis, obtaining syringes from syringe exchange programs was found to be protective against improper disposal, and injecting in public places was predictive of improper disposal. Few syringes posed a public health threat. PMID:20466956

  19. Pharmacy access to sterile syringes for injection drug users: attitudes of participants in a syringe exchange program.

    PubMed

    Junge, B; Vlahov, D; Riley, E; Huettner, S; Brown, M; Beilenson, P

    1999-01-01

    To examine attitudes of participants of a van-based syringe exchange program (SEP) toward the hypothetical prospect of pharmacy-based syringe access. One-time, cross-sectional survey. Baltimore, Maryland. 206 injection drug users who participate in the Baltimore SEP. Face-to-face interviews. Location preferred for obtaining syringes, drug and syringe use, past experience with pharmacies, and willingness to pay. The sample was 67% men, 95% African American, and 95% unemployed; mean age was 39.8 years. A total of 19% of respondents had bought syringes at a pharmacy during the prior six months. Some 37% reported having been turned down when asking for syringes at a pharmacy, most commonly due to lack of identification to prove diabetic status (50%). If legal restrictions were lifted, 92% of respondents would obtain syringes from pharmacies, and would be willing to pay a mean price of $0.80 (median = $1.00) per syringe. Women were more likely than men to report the intention to switch from van-based SEP to pharmacy (57% versus 38%, p = .045). If current legal restrictions were lifted, pharmacies would be a viable syringe source appealing particularly to women, suggesting gender-specific access issues that should be addressed. The per-syringe price that study participants would be willing to pay exceeds typical retail prices, suggesting that pharmacists could charge enough per syringe to recoup operational costs.

  20. Social network-related risk factors for bloodborne virus infections among injection drug users receiving syringes through secondary exchange.

    PubMed

    De, Prithwish; Cox, Joseph; Boivin, Jean-François; Platt, Robert W; Jolly, Ann M

    2008-01-01

    Secondary syringe exchange (SSE) refers to the exchange of sterile syringes between injection drug users (IDUs). To date there has been limited examination of SSE in relation to the social networks of IDUs. This study aimed to identify characteristics of drug injecting networks associated with the receipt of syringes through SSE. Active IDUs were recruited from syringe exchange and methadone treatment programs in Montreal, Canada, between April 2004 and January 2005. Information on each participant and on their drug-injecting networks was elicited using a structured, interviewer-administered questionnaire. Subjects' network characteristics were examined in relation to SSE using regression models with generalized estimating equations. Of 218 participants, 126 were SSE recipients with 186 IDUs in their injecting networks. The 92 non-recipients reported 188 network IDUs. Networks of SSE recipients and non-recipients were similar with regard to network size and demographics of network members. In multivariate analyses adjusted for age and gender, SSE recipients were more likely than non-recipients to self-report being HIV-positive (OR=3.56 [1.54-8.23]); require or provide help with injecting (OR=3.74 [2.01-6.95]); have a social network member who is a sexual partner (OR=1.90 [1.11-3.24]), who currently attends a syringe exchange or methadone program (OR=2.33 [1.16-4.70]), injects daily (OR=1.77 [1.11-2.84]), and shares syringes with the subject (OR=2.24 [1.13-4.46]). SSE is associated with several injection-related risk factors that could be used to help focus public health interventions for risk reduction. Since SSE offers an opportunity for the dissemination of important prevention messages, SSE-based networks should be used to improve public health interventions. This approach can optimize the benefits of SSE while minimizing the potential risks associated with the practice of secondary exchange.

  1. Residual Injection Risk Behavior, HIV Infection, and the Evaluation of Syringe Exchange Programs

    ERIC Educational Resources Information Center

    Des Jarlais, Don C.; Braine, Naomi; Yi, Huso; Turner, Charles

    2007-01-01

    This study assessed relationships between residual risk behavior (risk behavior among persons participating in effective HIV prevention programs) and HIV infection. Structured interviews and HIV tests were obtained from participants in six large U.S. syringe exchange programs. Program characteristics were obtained through interviews with the…

  2. Neighborhood History as a Factor Shaping Syringe Distribution Networks Among Drug Users at a U.S. Syringe Exchange1

    PubMed Central

    Braine, Naomi; Acker, Caroline; Goldblatt, Cullen; Yi, Huso; Friedman, Samuel; DesJarlais, Don C.

    2008-01-01

    Throughout the US, high-visibility drug markets are concentrated in neighborhoods with few economic opportunities, while drug buyers/users are widely dispersed. A study of Pittsburgh Syringe Exchange participants provides data on travel between and network linkages across neighborhoods with different levels of drug activity. There are distinct racial patterns to syringe distribution activity within networks and across neighborhoods. Pittsburgh’s history suggests these patterns emerge from historical patterns of social and economic development. Study data demonstrate the ability of IDUs to form long term social ties across racial and geographic boundaries and use them to reduce the risk of HIV transmission. PMID:19578475

  3. Comparison of injection drug users accessing syringes from pharmacies, syringe exchange programs, and other syringe sources to inform targeted HIV prevention and intervention strategies

    PubMed Central

    Rudolph, Abby E.; Crawford, Natalie D.; Ompad, Danielle C.; Benjamin, Ebele O.; Stern, Rachel J.; Fuller, Crystal M.

    2011-01-01

    Objective In New York, syringe exchange programs (SEPs) and pharmacies provide syringe access for IDUs but may be unable to meet the needs of all IDUs. This analysis aims to describe IDUs who access syringes through different outlets to help inform the prevention needs of IDUs who under-utilize safe syringe sources in a city where syringe availability is high relative to other U.S. cities. Design Cross-sectional study Setting New York City (2005–2007) Participants 285 IDUs recruited using street-intercept sampling Intervention(s) Not Applicable Main outcome measure(s) IDUs using SEPs, pharmacies, or other outlets as a primary syringe source were compared by sociodemographic characteristics, injection practices and medical service utilization. Results Chi-square tests and polytomous logistic regression were used to compare IDUs with different self-reported primary syringe sources used 6 months prior to study entry. Compared with IDUs using other syringe sources, those using primarily SEPs were less likely to be Black (AOR:0.26 95%CI:0.11–0.57), more likely to inject daily (AOR:3.32; 95%CI:1.58–6.98), and more likely to inject with a new syringe (AOR:2.68; 95%CI:1.30–5.54). Compared with IDUs using other syringe sources, those using primarily pharmacies were less likely to be Black (AOR:0.39; 95%CI0.17–0.90). Conclusion These data suggest that pharmacies and SEPs may be reaching different populations of IDUs and highlight a sub-population of highly marginalized IDUs (Black and infrequent injectors) who are under-utilizing safe syringe sources in New York City. Targeted interventions are needed to reduce racial disparities and increase utilization of safe syringe outlets. PMID:20199954

  4. Syringe vending machines for injection drug users: an experiment in Marseille, France.

    PubMed Central

    Obadia, Y; Feroni, I; Perrin, V; Vlahov, D; Moatti, J P

    1999-01-01

    OBJECTIVES: This study evaluated the usefulness of vending machines in providing injection drug users with access to sterile syringes in Marseille, France. METHODS: Self-administered questionnaires were offered to 485 injection drug users obtaining syringes from 32 pharmacies, 4 needle exchange programs, and 3 vending machines. RESULTS: Of the 343 respondents (response rate = 70.7%), 21.3% used the vending machines as their primary source of syringes. Primary users of vending machines were more likely than primary users of other sources to be younger than 30 years, to report no history of drug maintenance treatment, and to report no sharing of needles or injection paraphernalia. CONCLUSIONS: Vending machines may be an appropriate strategy for providing access to syringes for younger injection drug users, who have typically avoided needle exchange programs and pharmacies. PMID:10589315

  5. Prevalence and predictors of transitions to and away from syringe exchange use over time in 3 US cities with varied syringe dispensing policies

    PubMed Central

    Green, Traci C.; Bluthenthal, Ricky N.; Singer, Merrill; Beletsky, Leo; Grau, Lauretta E.; Marshall, Patricia; Heimer, Robert

    2010-01-01

    Syringe exchange programs (SEPs) can reduce HIV risk among injecting drug users (IDUs) but their use may depend heavily on contextual factors such as local syringe policies. The frequency and predictors of transitioning over time to and from direct, indirect, and non-use of SEPs are unknown. We sought, over one year, to: (1) quantify and characterize transition probabilities of SEP attendance typologies; (2) identify factors associated with (a) change in typology, and (b) becoming and maintaining direct SEP use; and (3) quantify and characterize transition probabilities of SEP attendance before and after changes in policy designed to increase access. Using data collected from 583 IDUs participating in a three-city cohort study of SEPs, we conducted a latent transition analysis and multinomial regressions. Three typologies were detected: Direct SEP users, Indirect SEP users and Isolated IDUs. Transitions to direct SEP use were most prevalent. Factors associated with becoming or maintaining direct SEP use were female sex, Latino ethnicity, fewer injections per syringe, homelessness, recruitment city, injecting speedballs (cocaine and heroin), and police contact involving drug paraphernalia possession. Similar factors influenced transitions in the syringe policy change analysis. Policy change cities experienced an increase in Indirect SEP users (43% to 51%) with little increased direct use (29% to 31%). We found that, over time, IDUs tended to become Direct SEP users. Policies improving syringe availability influenced SEP use by increasing secondary syringe exchange. Interactions with police around drug paraphernalia may encourage SEP use for some IDUs and may provide opportunities for other health interventions. PMID:20537814

  6. Racial differences in acquisition of syringes from pharmacies under conditions of legal but restricted sales.

    PubMed

    Costenbader, Elizabeth C; Zule, William A; Coomes, Curtis C

    2010-09-01

    Injecting drug users (IDUs) are at increased risk of acquiring and transmitting HIV and other bloodborne pathogens through the multi-person use of syringes. Although research has shown that increased access to syringes through syringe exchange programs (SEPs) is an effective strategy to reduce risky injection practices many areas of the United States still do not have SEPs. In the absence of SEPs, legislation allowing pharmacies over-the-counter sales of syringes has also been shown to reduce syringe sharing. The success of pharmacy sales however is limited by other legal stipulations, such as drug paraphernalia laws, which in turn may contribute to fear among IDUs about being caught purchasing and carrying syringes. Between 2003 and 2006, 851 out-of-treatment IDUs were recruited using street outreach in the Raleigh-Durham (North Carolina) area. Data were collected using audio-computer assisted interview (ACASI) technology. Multiple logistic regression analyses were performed to assess factors associated with purchasing syringes from pharmacies. In our study sample, African-American IDUs were one-fifth as likely as white IDUs to report pharmacies as their primary source of syringes. Given the absence of syringe exchange programs and the relatively high prevalence of HCV and HIV among IDUs in the Raleigh-Durham area, the limited use of pharmacies as a source of syringes among African-American IDUs in this study sample is problematic. The study findings support the need for effective multilevel interventions to increase access to clean needles in this population, as well as for policy interventions, such as legalization of SEPs and elimination of penalties for carrying syringes, to reduce harm and eliminate the health threats posed by receptive syringe sharing. Copyright 2010 Elsevier B.V. All rights reserved.

  7. HIV Risk Behavior among Amphetamine Injectors at U.S. Syringe Exchange Programs

    ERIC Educational Resources Information Center

    Braine, Naomi; Des Jarlais, Don C.; Goldblatt, Cullen; Zadoretzky, Cathy; Turner, Charles

    2005-01-01

    The goal of this study was to compare HIV risk behaviors of amphetamine and non-amphetamine injectors at syringe exchange programs (SEP) in the United States and to identify factors associated with injection risk. This analysis is based on data from a random cross-section of participants at 13 SEPs in different parts of the country. All interviews…

  8. Who purchases nonprescription syringes? Characterizing customers of the Expanded Syringe Access Program (ESAP).

    PubMed

    Battles, Haven B; Rowe, Kirsten A; Ortega-Peluso, Christina; Klein, Susan J; Tesoriero, James M

    2009-11-01

    This study represents the first attempt in the USA to survey pharmacy nonprescription syringe customers at their point of purchase. We surveyed 62 individuals purchasing nonprescription syringes in seven pharmacies located in NYC and Albany, NY, USA. Three quarters of respondents purchased for illicit use, and 36% purchased for medical use, with differences found by race and gender. Half got their syringes from pharmacies "most of the time." Half had ever been refused a syringe purchase in a NYS pharmacy, with men, Blacks, and Hispanics reporting higher levels of refusals than women or whites. Two thirds reported syringe reuse but very few reported sharing. While approximately one quarter safely obtained and disposed of syringes "most of the time," two thirds used both safe and unsafe methods. Pharmacy-based syringe access programs are essential in areas not served by syringe exchanges.

  9. Safe syringe disposal is related to safe syringe access among HIV-positive injection drug users.

    PubMed

    Coffin, Phillip O; Latka, Mary H; Latkin, Carl; Wu, Yingfeng; Purcell, David W; Metsch, Lisa; Gomez, Cynthia; Gourevitch, Marc N

    2007-09-01

    We evaluated the effect of syringe acquisition on syringe disposal among HIV-positive injection drug users (IDUs) in Baltimore, New York City, and San Francisco (N = 680; mean age 42 years, 62% male, 59% African-American, 21% Hispanic, 12% White). Independent predictors of safe disposal were acquiring syringes through a safe source and ever visiting a syringe exchange program. Weaker predictors included living in San Francisco, living in the area longer, less frequent binge drinking, injecting with an HIV+ partner, peer norms supporting safe injection, and self-empowerment. Independent predictors of safe "handling"-both acquiring and disposing of syringes safely-also included being from New York and being older. HIV-positive IDUs who obtain syringes from a safe source are more likely to safely dispose; peer norms contribute to both acquisition and disposal. Interventions to improve disposal should include expanding sites of safe syringe acquisition while enhancing disposal messages, alternatives, and convenience.

  10. Professional ideologies and the development of syringe exchange: Wales as a case study.

    PubMed

    Keene, J M; Stimson, G V

    1997-12-01

    This paper is derived from an evaluative study of HIV prevention programs for drug injectors across Wales. It considers how different professional territories and ideologies, concepts of drug misuse and models of HIV prevention may influence policy development. The research involved monitoring the introduction and development of agency and community based syringe exchange schemes and initiatives taken by community pharmacists. Interviews with staff, managers and administrators, and descriptions of service history, development and delivery inform the discussion. HIV prevention varied in different areas of Wales depending on the particular professional group involved, local ideologies regarding drug use treatment, and the extent to which HIV prevention was seen either as a specialist area of expertise and specific remit of drug workers or a generic health care task. Drug agencies with an abstinence policy rejected syringe exchange; instead, prevention in those areas developed in ad hoc ways as health care workers and pharmacists attempted to develop a community based service. Drug agencies with a pre-existing harm minimisation model easily integrated syringe exchange into their work and played the major part in establishing the service, but there was difficulty in extending it beyond their professional caseloads. As there were disincentives to use treatment agencies, and their catchment areas were limited, these factors influenced effective service provision.

  11. Syringe disposal among injection drug users in Harlem and the Bronx during the New York State Expanded Syringe Access Demonstration Program.

    PubMed

    Cleland, Charles M; Deren, Sherry; Fuller, Crystal M; Blaney, Shannon; McMahon, James M; Tortu, Stephanie; Des Jarlais, Don C; Vlahov, David

    2007-04-01

    Effective January 1, 2001, New York State enacted the Expanded Syringe Access Demonstration Program (ESAP), allowing syringes to be sold in pharmacies without a prescription or dispensed through doctors, hospitals, and clinics to adults. A concern in the assessment of ESAP is its effects on syringe disposal practices. Syringe use data regarding the last injection episode were combined from three projects (N = 1,030) recruiting injection drug users. Disposal of syringes by methods known to be safe decreased significantly over time after the implementation of ESAP. Syringes obtained either from syringe exchange programs or ESAP sources were more likely to be disposed of safely than syringes obtained from other sources. Efforts to enlist pharmacists and others involved in ESAP implementation to encourage safe disposal are needed. More detailed information on disposal practices is needed to capture the continuum from least to most safe practices and variation within individuals.

  12. Determination of the Specific Heat Ratio of a Gas in a Plastic Syringe

    ERIC Educational Resources Information Center

    Chamberlain, Jeff

    2010-01-01

    The rapid compression or expansion of a gas in a plastic syringe is a poor approximation of an adiabatic process. Heat exchange with the walls of the syringe brings the gas to equilibrium in an amount of time that is not significantly greater than the length of the compression or expansion itself. Despite this limitation, it is still possible to…

  13. Multiple access to sterile syringes for injection drug users: vending machines, needle exchange programs and legal pharmacy sales in Marseille, France.

    PubMed

    Moatti, J P; Vlahov, D; Feroni, I; Perrin, V; Obadia, Y

    2001-03-01

    In Marseille, southeastern France, HIV prevention programs for injection drug users (IDUs) simultaneously include access to sterile syringes through needle exchange programs (NEPs), legal pharmacy sales and, since 1996, vending machines that mechanically exchange new syringes for used ones. The purpose of this study was to compare the characteristics of IDUs according to the site where they last obtained new syringes. During 3 days in September 1997, all IDUs who obtained syringes from 32 pharmacies, four NEPs and three vending machines were offered the opportunity to complete a self-administered questionnaire on demographics, drug use characteristics and program utilization. Of 485 individuals approached, the number who completed the questionnaire was 141 in pharmacies, 114 in NEPs and 88 at vending machines (response rate = 70.7%). Compared to NEP users, vending machine users were younger and less likely to be enrolled in a methadone program or to report being HIV infected, but more likely to misuse buprenorphine. They also had lower financial resources and were less likely to be heroin injectors than both pharmacy and NEP users. Our results suggest that vending machines attract a very different group of IDUs than NEPs, and that both programs are useful adjuncts to legal pharmacy sales for covering the needs of IDUs for sterile syringes in a single city. Assessment of the effectiveness and cost-effectiveness of combining such programs for the prevention of HIV and other infectious diseases among IDUs requires further comparative research. Copyright 2001 S. Karger AG, Basel

  14. Trend Analyses of Users of a Syringe Exchange Program in Philadelphia, Pennsylvania: 1999-2014.

    PubMed

    Maurer, Laurie A; Bass, Sarah Bauerle; Ye, Du; Benitez, José; Mazzella, Silvana; Krafty, Robert

    2016-12-01

    This study examines trends of injection drug users' (IDUs) use of a Philadelphia, Pennsylvania, syringe exchange program (SEP) from 1999 to 2014, including changes in demographics, drug use, substance abuse treatment, geographic indicators, and SEP use. Prevention Point Philadelphia's SEP registration data were analyzed using linear regression, Pearson's Chi square, and t-tests. Over time new SEP registrants have become younger, more racially diverse, and geographically more concentrated in specific areas of the city, corresponding to urban demographic shifts. The number of new registrants per year has decreased, however syringes exchanged have increased. Gentrification, cultural norms, and changes in risk perception are believed to have contributed to the changes in SEP registration. Demographic changes indicate outreach strategies for IDUs may need adjusting to address unique barriers for younger, more racially diverse users. Implications for SEPs are discussed, including policy and continued ability to address current public health threats.

  15. Building a city wide service for exchanging needles and syringes.

    PubMed Central

    Gruer, L; Cameron, J; Elliott, L

    1993-01-01

    How best can injecting drug misusers obtain clean injecting equipment in a city where drug injecting is widespread? An exchange service for needles and syringes throughout Glasgow has been established in health centres and clinics in the evening. Over the past four years seven new exchanges have been opened and over 2700 injecting drug misusers have attended. Attendances rose from under 1000 in 1988 to 28,000 in 1992. The exchanges also provide a wide range of other health and social services. Public hostility to the exchanges has abated. During the same period equipment sharing in the city diminished and the observed prevalence of HIV among injecting drug misusers stabilised at around 1%. Images FIG 1 FIG 2 FIG 3 PMID:8518609

  16. Federal funding for syringe exchange in the US: Explaining a long-term policy failure.

    PubMed

    Showalter, David

    2018-05-01

    The United States prohibited federal funding for syringe exchange programs for people who inject drugs nearly continuously from 1988 to 2015, despite growing scientific evidence, diminishing AIDS-related controversy, and tens of thousands of deaths from injection-related AIDS. This study investigates the political and institutional bases of this long-term failure to support lifesaving public policy. This study draws on national, regional, and local media coverage, archival sources, and semi-structured, in-depth interviews with 6 long-time syringe exchange researchers and activists from California. I use case-oriented process tracing methods to explain the persistence and reform of the federal funding ban. Though previous studies focus on the symbolic clash between conservative morality and empirical science, I find that changing demographic and regional inequalities in the effects of the AIDS epidemic and dynamics produced by the federal structure of US government were more important factors in the creation and persistence of the funding ban. The persistence and eventual repeal of the ban on federal funding for syringe exchange was a product of the changing demographic, geographic, and political effects of the AIDS epidemic within the federal structure of US government, rather than a consequence of intractable morality politics. These contextual dynamics continue to shape AIDS and public health policy at all levels of government. Copyright © 2018. Published by Elsevier B.V.

  17. Greater Drug Injecting Risk for HIV, HBV, and HCV Infection in a City Where Syringe Exchange and Pharmacy Syringe Distribution are Illegal

    PubMed Central

    Zhao, Mingfang; Gyarmathy, V. Anna; Cisek, Linda; Friedman, Samuel R.; Baxter, Robert C.

    2008-01-01

    Comparing drug-injecting risk between cities that differ in the legality of sterile syringe distribution for injection drug use provides a natural experiment to assess the efficacy of legalizing sterile syringe distribution as a structural intervention to prevent human immunodeficiency virus (HIV) and other parenterally transmitted infections among injection drug users (IDUs). This study compares the parenteral risk for HIV and hepatitis B (HBV) and C (HCV) infection among IDUs in Newark, NJ, USA, where syringe distribution programs were illegal during the period when data were collected, and New York City (NYC) where they were legal. IDUs were nontreatment recruited, 2004–2006, serotested, and interviewed about syringe sources and injecting risk behaviors (prior 30 days). In multivariate logistic regression, adjusted odds ratios (AOR) and 95% confidence intervals (95% CI) for city differences are estimated controlling for potential city confounders. IDUs in Newark (n = 214) vs. NYC (n = 312) were more likely to test seropositive for HIV (26% vs. 5%; AOR = 3.2; 95% CI = 1.6, 6.1), antibody to the HBV core antigen (70% vs. 27%; AOR = 4.4; 95% CI = 2.8, 6.9), and antibody to HCV (82% vs. 53%; AOR = 3.0; 95% CI = 1.8, 4.9), were less likely to obtain syringes from syringe exchange programs or pharmacies (AOR = 0.004; 95% CI = 0.001, 0.01), and were more likely to obtain syringes from street sellers (AOR = 74.0; 95% CI = 29.9, 183.2), to inject with another IDU’s used syringe (AOR = 2.3; 95% CI = 1.1, 5.0), to reuse syringes (AOR = 2.99; 95% CI = 1.63, 5.50), and to not always inject once only with a new, sterile syringe that had been sealed in a wrapper (AOR = 5.4; 95% CI = 2.9, 10.3). In localities where sterile syringe distribution is illegal, IDUs are more likely to obtain syringes from unsafe sources and to engage in injecting risk behaviors. Legalizing and rapidly implementing sterile syringe distribution programs are critical for reducing parenterally transmitted HIV, HBV, and HCV among IDUs. PMID:18340537

  18. Drug-Related Arrest Rates and Spatial Access to Syringe Exchange Programs in New York City Health Districts: Combined Effects on the Risk of Injection-Related Infections among Injectors

    PubMed Central

    Jarlais, Don C Des; Tempalski, Barbara; Bossak, Brian H; Ross, Zev; Friedman, Samuel R

    2011-01-01

    Drug-related law enforcement activities may undermine the protective effects of syringe exchange programs (SEPs) on local injectors’ risk of injection-related infections. We explored the spatial overlap of drug-related arrest rates and access to SEPs over time (1995-2006) in New York City health districts, and used multilevel models to investigate the relationship of these two district-level exposures to the odds of injecting with an unsterile syringe. Districts with better SEP access had higher arrest rates, and arrest rates undermined SEPs’ protective relationship with unsterile injecting. Drug-related enforcement strategies targeting drug users should be de-emphasized in areas surrounding SEPs. PMID:22047790

  19. Sterile syringe access and disposal among injection drug users newly enrolled in methadone maintenance treatment: a cross-sectional survey

    PubMed Central

    McNeely, Jennifer; Arnsten, Julia H; Gourevitch, Marc N

    2006-01-01

    Background We sought to assess injection practices, means of acquiring and disposing of syringes, and utilization and knowledge of harm reduction resources among injection drug users (IDUs) entering methadone maintenance treatment (MMT). Methods Interviews with 100 consecutive patients, including 35 IDUs, entering a MMT program in the Bronx, NY. Results Utilization of unsafe syringe sources was reported by 69% of IDUs in our sample. Most (80%) IDUs reused syringes, and syringe sharing was also common. Fewer than half knew that non-prescription pharmacy purchase of syringes was possible. The most common means of disposing of injecting equipment were the trash (63%) and syringe exchange programs (49%). Conclusions These findings indicate that drug users entering treatment under-utilize sanctioned venues to obtain sterile syringes or safely dispose of used injection equipment. Programs providing services to drug users should adopt a proactive stance to address the safety and health issues faced by injectors. PMID:16503997

  20. Time to act: a call for comprehensive responses to HIV in people who use drugs

    PubMed Central

    Beyrer, Chris; Malinowska-Sempruch, Kasia; Kamarulzaman, Adeeba; Kazatchkine, Michel; Sidibe, Michel; Strathdee, Steffanie A

    2013-01-01

    The published work on HIV in people who use drugs shows that the global burden of HIV infection in this group can be reduced. Concerted action by governments, multilateral organisations, health systems, and individuals could lead to enormous benefits for families, communities, and societies. We review the evidence and identify synergies between biomedical science, public health, and human rights. Cost-effective interventions, including needle and syringe exchange programmes, opioid substitution therapy, and expanded access to HIV treatment and care, are supported on public health and human rights grounds; however, only around 10% of people who use drugs worldwide are being reached, and far too many are imprisoned for minor offences or detained without trial. To change this situation will take commitment, advocacy, and political courage to advance the action agenda. Failure to do so will exacerbate the spread of HIV infection, undermine treatment programmes, and continue to expand prison populations with patients in need of care. PMID:20650515

  1. Micro-fluid exchange coupling apparatus

    NASA Technical Reports Server (NTRS)

    Johnson, J. E., Jr.; Swartz, P. F. (Inventor)

    1980-01-01

    In a macro-fluid exchange, a hollow needle, such as a syringe needle, is provided for penetrating the fluid conduit of the animal. The syringe needle is coupled to a plenum chamber having an inlet and outlet port. The plenum chamber is coupled to the syringe needle via the intermediary of a standard quick disconnect coupling fitting. The plenum chamber is carried at the end of a drive rod which is coupled to a micrometer drive head. The micrometer drive head is slidably and pivotably coupled to a pedestal for adjusting the height and angle of inclination of the needle relative to a reference base support. The needle is positioned adjacent to the incised trachea or a blood vessel of a small animal and the micrometer drive head is operated for penetrating the fluid conduit of the animal.

  2. Auto-disable syringes for immunization: issues in technology transfer.

    PubMed Central

    Lloyd, J. S.; Milstien, J. B.

    1999-01-01

    WHO and its partners recommend the use of auto-disable syringes, "bundled" with the supply of vaccines when donor dollars are used, in all mass immunization campaigns, and also strongly advocate their use in routine immunization programmes. Because of the relatively high price of auto-disable syringes, WHO's Technical Network for Logistics in Health recommends that activities be initiated to encourage the transfer of production technology for these syringes as a means of promoting their use and enhancing access to the technology. The present article examines factors influencing technology transfer, including feasibility, corporate interest, cost, quality assurance, intellectual property considerations, and probable time frames for implementation. Technology transfer activities are likely to be complex and difficult, and may not result in lower prices for syringes. Guidelines are offered on technology transfer initiatives for auto-disable syringes to ensure the quality of the product, the reliability of the supply, and the feasibility of the technology transfer activity itself. PMID:10680248

  3. Syringe access for the prevention of blood borne infections among injection drug users

    PubMed Central

    Stancliff, Sharon; Agins, Bruce; Rich, Josiah D; Burris, Scott

    2003-01-01

    Background Approximately one-third of acquired immunodeficiency syndrome cases in the United States are associated with the practice of sharing of injection equipment and are preventable through the once-only use of syringes, needles and other injection equipment. Discussion Sterile syringes may be obtained legally by 4 methods depending on the state. They may be purchased over the counter, prescribed, obtained at syringe exchange programs or furnished by authorized agencies. Each of these avenues has advantages and disadvantages; therefore, legal access through all means is the most likely way to promote the use of sterile syringes. Summary By assisting illicit drug injectors to obtain sterile syringes the primary care provider is able to reduce the incidence of blood borne infections, and educate patients about safe syringe disposal. The provider is also able to initiate discussion about drug use in a nonjudgmental manner and to offer care to patients who are not yet ready to consider drug treatment. PMID:14633286

  4. New York City pharmacists' attitudes toward sale of needles/syringes to injection drug users before implementation of law expanding syringe access.

    PubMed

    Coffin, P O; Linas, B P; Factor, S H; Vlahov, D

    2000-12-01

    In May 2000, New York State passed legislation permitting the sale, purchase, and possession of up to 10 needles and syringes (hereafter "syringes") without a prescription, intended to reduce blood-borne pathogen transmission among injection drug users (IDUs). To obtain baseline data on pharmacists' attitudes and practices related to human immunodeficiency virus (HIV) prevention and IDUs, a telephone survey was administered to 130 pharmacists systematically selected in New York City. Less than half of pharmacists were aware of the new law; 49.6% were willing to or supported providing nonprescription sales of syringes to IDUs. Pharmacists in support tended to be less likely to consider customer appearance "very important." Managing and supervising pharmacists were more likely than staff pharmacists to support syringe sales to IDUs. Managing and supervising pharmacists who stocked packs of 10 syringes and personal sharps disposal containers, pharmacists who supported syringe exchange in the pharmacy, and pharmacists who were willing to sell syringes to diabetics without a prescription were more likely to support syringe sales to IDUs. Syringe disposal was a prominent concern among all pharmacists. Those not in support of syringe sales to IDUs tended to be more likely to believe the practice would increase drug use. These data suggest the need for initiatives to address concerns about syringe disposal and tailored continuing education classes for pharmacists on HIV and viral hepatitis prevention among IDUs.

  5. The development of peer educator-based harm reduction programmes in Northern Vietnam.

    PubMed

    Walsh, Nick; Gibbie, Tania M; Higgs, Peter

    2008-03-01

    Injecting drug use remains an important risk factor for transmission in Vietnam, with an estimated 50% of the 290 000 people living with HIV/AIDS reporting injecting drug use as a risk factor. Despite this, effective harm reduction interventions are generally lacking. This paper describes the implementation of peer-based harm reduction programmes in two rural provinces of Vietnam. Peer educators were trained in basic HIV prevention, including harm reduction. After significant preparation work with the Provincial AIDS Committees of Bac Giang and Thanh Hoa and other relevant national, provincial and local authorities, the interventions were commenced. Harm reduction interventions were delivered through outreach as well as on-site. This included needle and syringe distribution and collection. Community advocacy occurred throughout the life of the project. Local authorities and peers believed that while there was a general reduction in stigma and discrimination, legal barriers associated particularly with the carrying of injecting equipment remained. This impacted upon the ability of peer educators to work with their clients. Peer-based delivery of harm reduction intervention is acceptable. Harm reduction interventions, including needle and syringe programmes, are feasible and acceptable in these two rural Vietnamese provinces. Community acceptance and uptake of these interventions is key to successful expansion across the region. Active participation by families of drug users seems crucial. This initiative demonstrates that despite a difficult policy environment, peer-delivered needle and syringe programmes are feasible within a rural Asian environment as long as there is adequate local political and community support.

  6. Access to Sterile Syringes through San Francisco Pharmacies and the Association with HIV Risk Behavior among Injection Drug Users

    PubMed Central

    Kral, Alex H.; Stopka, Thomas J.; Garfein, Richard S.; Reuckhaus, Paul; Bluthenthal, Ricky N.

    2010-01-01

    Increased options for syringe acquisition and disposal have been associated with reductions in high-risk behaviors. This study determined the extent of pharmacy uptake in accessing syringes among injection drug users (IDUs) and estimated associations between pharmacy uptake and safer injection/disposal practices. Two years after the implementation of California’s Disease Prevention Demonstration Project, which removed restrictions to non-prescription syringe sales through pharmacies with local authorization, IDUs were recruited through street outreach in San Francisco and interviewed regarding recent syringe acquisition, use, and disposal. The sample of 105 persons included a high proportion of men (67%), people of color (49%), and homeless persons (71%). The most common syringe source was a syringe exchange program (SEP) (80%), with pharmacies being accessed by 39% of respondents. The most commonly cited source of disposal was a SEP (65%), with very few reports of pharmacy disposal (2%). Adjusted analysis showed that unsuccessful attempts to purchase syringes at a pharmacy increased the odds of both injecting with a used syringe and giving away a used syringe. Using a SEP decreased the odds of unsafe injection and disposal practices. Thus, 2 years after the initiation of the California Disease Prevention Demonstration Project, results from this small study suggest that SEPs still provide the majority of syringe distribution and disposal services to San Francisco IDUs; however, pharmacies now augment syringe access. In addition, unsafe injection behavior is reported more often among those who do not use these syringe sources. These results are consistent with prior studies in suggesting that increasing the availability of syringes through SEPs and pharmacies, and developing bridges between them, may further reduce syringe-related risk. PMID:20526690

  7. Expanding harm reduction services through a wound and abscess clinic.

    PubMed

    Grau, Lauretta E; Arevalo, Silvia; Catchpool, Christopher; Heimer, Robert

    2002-12-01

    A wound and abscess clinic, held concurrently with a syringe exchange, provided economical treatment and aftercare for injection-associated soft tissue infections. During 20 two-hour clinic sessions, 173 treatment episodes were logged, and the visit cost was estimated at $5 per patient. Increased patient-clinician interactions provided opportunities beyond those afforded by the syringe exchange for patients to obtain resources and referrals to services such as HIV counseling and testing, medical care, and drug treatment. Distribution of cards advertising the clinic was substantially less effective than word of mouth in increasing community awareness of the clinic.

  8. Home medication injection among Latina women in Los Angeles: implications for health education and prevention.

    PubMed

    Flaskerud, J H; Nyamathi, A M

    1996-02-01

    Reuse of needles and syringes after home injection of medications and vitamins may be a risk for transmission of HIV. An exploratory study was done to determine (1) how commonly injectable medications were used in the home; (2) whether needles and syringes were reused; and (3) common practices for cleaning needles and syringes. A survey was conducted of low income Latina women (n = 216) who were attending a Public Health Foundation nutrition programme for women, infants and children (WIC) in Los Angeles. To clarify and expand on the survey findings, focus group interviews were done with an additional 55 women attending WIC. Quantitative data were analysed using descriptive and comparative statistics. Qualitative data were subjected to content analysis. The use of injectable medications purchased in Mexico was fairly common (43.5%); reuse of disposable needles and syringes (48%) and sharing (36%) among injectors were also common. Methods of cleaning needles and syringes were inadequate to CDC recommended guidelines. Injectors and non-injectors differed significantly in ethnicity, religion, and marital status. The only significant predictor of medication injection was educational level. Analysis of qualitative data revealed the reasons that Latina subjects were injecting medication; how they were transporting medicines from Mexico; and how they were cleaning their equipment. The practical implications for health education and prevention programmes should include an awareness that home use and reuse of needles for injection of medications may be common in some social groups and that knowledge of the potential dangers in reuse and sharing of needles may not extend to home medication injection.

  9. Knowledge of tuberculosis among drug users. Relationship to return rates for tuberculosis screening at a syringe exchange.

    PubMed

    Salomon, N; Perlman, D C; Friedmann, P; Perkins, M P; Ziluck, V; Jarlais, D C; Paone, D

    1999-04-01

    Tuberculosis is an important health issue among drug users. We sought to evaluate active drug users' (DUs) knowledge of tuberculosis (TB) and to assess the relationship between TB knowledge and attitudes and tuberculin skin test (TST) return rates at a syringe exchange program. DUs were recruited at a syringe exchange program in New York City, were interviewed and offered TSTs, and received $15.00 upon returning for TST reading. The questionnaire evaluated knowledge of TB transmission, prevention, and treatment. From March 13, 1995 to January 31, 1996, 610 of 650 (94%) of DUs approached agreed to participate. Of these, 80% had previous TSTs within the past 2 years and 20% were known to be HIV infected. Almost all knew that TB is contagious and more than two thirds knew that TB is treatable and that TB preventive therapy existed. However, fewer than half knew that HIV-related TB could be treated, 30% thought TB could be treated without a medical doctor, and the majority (70%) thought a reactive TST implied infectivity. The rate of return for TST reading was 93%. In multivariate analysis, those who knew that HIV-related TB was curable were more likely to return for TST reading (odds ratio 2.0; 95% confidence interval 1.04 to 3.95; p = .03). The high acceptance and return rates suggest that TB services can be incorporated into syringe exchange programs. However, several important gaps in TB knowledge existed in this population at high risk of TB, which may impact on adherence and which support the need for TB education for drug users.

  10. Food insecurity among people who inject drugs in Los Angeles and San Francisco.

    PubMed

    Schmitz, Jane; Kral, Alex H; Chu, Daniel; Wenger, Lynn D; Bluthenthal, Ricky N

    2016-08-01

    We estimated the prevalence of food insecurity among people who inject drugs (PWID) in Los Angeles and San Francisco and explored correlates of food insecurity. A cross-sectional study that measured 30 d food insecurity using the US Adult Food Security Survey ten-item Module developed by the US Department of Agriculture. Food insecurity was defined as including low and very low food security. Two cities in the state of California, USA. Male and female active PWID (n 777). Among participants, 58 % reported food insecurity and 41 % reported very low food security. Food-insecure PWID were more likely to report being homeless (prevalence ratio (PR)=1·20; 95 % CI 1·05, 1·37), chest pain in the past 12 months (PR=1·19; CI 1·06, 1·35), acquiring syringes from someone who goes to a syringe exchange programme (PR=1·27; 95 % CI 1·13, 1·43) and feeling at risk for arrest for possession of drug paraphernalia (PR=1·30; 95 % CI 1·15, 1·46). Current food insecurity was common among PWID in these two cities, yet few factors were independently associated with food insecurity. These data suggest that broad strategies to improve food access for this high-risk population are urgently needed.

  11. Needle and Syringe Cleaning Practices among Injection Drug Users.

    ERIC Educational Resources Information Center

    Fisher, Dennis G.; Harbke, Colin R.; Canty, John R.; Reynolds, Grace L.

    2002-01-01

    Evaluates the effect of needle exchange on the bleach-mediated disinfection (BMD) practices of 176 needle and syringe sharing injection drug users (IDUs). Results reveal that IDUs who traded sex for money or drugs were less likely to practice BMD, and IDUs who reported a reduced number of sex partners were more likely to practice BMD. (Contains 36…

  12. Malaysia and harm reduction: the challenges and responses.

    PubMed

    Reid, Gary; Kamarulzaman, Adeeba; Sran, Sangeeta Kaur

    2007-03-01

    In Malaysia the response to illicit drug use has been largely punitive with the current goal of the Malaysian government being to achieve a drug-free society by 2015. This paper outlines the results of a desk-based situation assessment conducted over a 3-week period in 2004. Additional events, examined in 2005, were also included to describe more recent policy developments and examine how these came about. Despite punitive drug policy there has been a substantial rise in the number of drug users in the country. Over two-thirds of HIV/AIDS cases are among injecting drug users (IDUs) and there has been an exponential rise in the number of cases reported. Further, data suggest high risk drug use practices are widespread. Harm reduction initiatives have only recently been introduced in Malaysia. The successful piloting of substitution therapies, in particular methadone and buprenorphine, is cause for genuine hope for the rapid development of such interventions. In 2005 the government announced it will allow methadone maintenance programmes to operate beyond the pilot phase and needle and syringe exchange programmes will be established to serve the needs of IDUs.

  13. Primary and secondary analysis of local elected officials' decisions to support or oppose pharmacy sale of syringes in California.

    PubMed

    Backes, Glenn; Rose, Valerie J

    2010-07-01

    Under California law, local governments may authorize pharmacies within their jurisdictions to sell ten or fewer syringes to an adult without prescription, proof of identity, or proof of medical need. Local governments may simultaneously exempt adults from prosecution for violation of state drug paraphernalia codes for possession of ten or fewer syringes for personal use. Both of these provisions are temporary and sunset on December 31, 2010, unless subsequent state legislation amends that date. The objective of our study was to ascertain how and why local policymakers made their decisions regarding non-prescription syringe sale (NPSS). We examined influences on their decisions, including specific messengers and the arguments that were most salient to their decision making. We selected jurisdictions that were geographically representative of California counties; those with and without syringe exchange programs, and those that had passed or rejected NPSS. We conducted nine semi-structured interviews in five jurisdictions. To enrich primary data collection, we analyzed secondary data by reviewing audio, video, and written transcripts of public hearings and newspaper coverage in five jurisdictions, including three jurisdictions without primary interview data. Among proponents of NPSS, we identified common themes, including: (1) public health research provided conclusive evidence for reduction in HIV and hepatitis transmission without problems of crime, drug use, or unsafe discard of syringes; (2) the local health officer was the key to influencing local policymakers; (3) recall of prior debates over syringe exchange served to inform their decision making; and (4) a lack of local opposition or controversy. Common concerns among opponents of NPSS included: (1) that there would be an increase in unsafe discard of syringes; (2) loss of an important law enforcement tool; (3) that drug users were incapable of desired behavior change; and (4) that research was inconclusive, or proved that syringe access would not work in reducing rates of disease. Themes held in common by proponents and opponents of NPSS were identified as well. Syringe access through NPSS is in fact supported by a robust body of public health research and is considered an important component of a comprehensive strategy to reduce HIV and hepatitis transmission. Our study highlights the importance of understanding the perspectives of elected officials in order to ameliorate their concerns without undermining the public health goal of reducing death, disease, and suffering in at-risk communities.

  14. Prospective effects of traumatic event re-exposure and post-traumatic stress disorder in syringe exchange participants.

    PubMed

    Peirce, Jessica M; Brooner, Robert K; Kolodner, Ken; Schacht, Rebecca L; Kidorf, Michael S

    2013-01-01

    Determine the effect of traumatic event re-exposure and post-traumatic stress disorder (PTSD) symptom severity on proximal drug use and drug abuse treatment-seeking in syringe exchange participants. Prospective longitudinal 16-month cohort study of new syringe exchange registrants enrolled in a parent study of methods to improve treatment engagement. Data were collected in a research van next to mobile syringe exchange distribution sites in Baltimore, Maryland. Male and female (n = 162) injecting drug users (IDUs) registered for syringe exchange. Traumatic event re-exposure was identified each month with the Traumatic Life Events Questionnaire. PTSD symptoms were measured with the Modified PTSD Symptom Scale-Revised, given every 4 months. Outcome measures collected monthly were days of drug use (heroin, cocaine) and drug abuse treatment-seeking behavior (interest, calls to obtain treatment, treatment participation). Each traumatic event re-exposure was associated with about 1 more day of cocaine use after accounting for the previous month's cocaine use [same month adjusted B, standard error = 1.16 (0.34); 1 month later: 0.99 (0.34)], while PTSD symptoms had no effect. Traumatic event re-exposure increased interest in drug abuse treatment [same month adjusted odds ratios with 95% confidence intervals = 1.34 (1.11-1.63)] and calling to obtain treatment [same month 1.58 (1.24-2.01); 1 month later 1.34 (1.03-1.75)]. Each 10% increase in PTSD symptom severity was associated with persistent increased interest in treatment [same month 1.25 (1.10-1.42); 1 month later 1.16 (1.02-1.32); 2 months later 1.16 (1.02-1.32)] and calling to obtain treatment [same month 1.16 (1.02-1.32)]. Neither traumatic events nor PTSD symptoms were associated with participants receiving treatment. Becoming exposed again to traumatic events among injecting drug users is associated with an increase in cocaine use up to 1 month later, but drug use is not related to post-traumatic stress disorder symptoms. Both traumatic event re-exposure and post-traumatic stress disorder symptoms predict drug abuse treatment-seeking behavior for up to 2 months. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  15. Expanding access to sterile syringes through pharmacies: assessment of New York's Expanded Syringe Access Program.

    PubMed

    Tesoriero, James M; Battles, Haven B; Klein, Susan J; Kaufman, Erin; Birkhead, Guthrie S

    2009-01-01

    To investigate the evolution of pharmacist practices, attitudes, and experiences with the Expanded Syringe Access Program (ESAP), which permits over-the-counter sale of syringes by registered pharmacies in New York State. Longitudinal study. New York State in 2002 and 2006. 506 (2002) and 682 (2006) managing pharmacists (response rates approximately 70%) at ESAP-registered pharmacies (n = 346 in both years). Mailed surveys (2002 and 2006). Pharmacist practices, attitudes, and experiences with ESAP over time. Approximately 75% of pharmacists reported that ESAP had facilitated timely/emergency access to syringes, and more than 90% in each year reported no problems or very few problems administering ESAP. The practice of placing additional requirements on the sale of syringes decreased from 2002 (51.4%) to 2006 (45.1%), while a 55% increase in syringe sales was reported between 2002 (43.3/month) and 2006 (67.1/month). The sale of sharps containers also increased between 2002 (85.2%) and 2006 (92.8%). Community independent pharmacies and those located outside New York City generally expressed more favorable attitudes and experiences with ESAP, although these differences decreased over time. Pharmacy-based syringe access is a viable harm-reduction alternative in the fight against blood-borne diseases, with ESAP now equaling the number of syringes being distributed by syringe exchange programs in New York State. Continued education/training is necessary to increase participation in ESAP and to further reduce barriers to ESAP use.

  16. Effectiveness of needle/syringe exchange program in Tbilisi.

    PubMed

    Otiashvili, D; Gambashidze, N; Kapanadze, E; Lomidze, G; Usharidze, D

    2006-11-01

    IDUs are under the high risk of HIV and other blood born diseases. In Georgia injecting drug use is associated with two third of registered HIV/AIDS cases. Majority of them are also infected with B and C Hepatitis. One of the main components of HIV/AIDS prevention among drug users is considered to be harm reduction programs, among them syringe exchange program. We conducted observational cohort study and performed interviewing participants of syringe exchange program using structured questionnaire. The interviewing was conducted at intake, after 3 months and at the end of the program. During interviewing we used risk assessment questionnaire which we have little adapted (Risk Assessment Battery, Navaline, et al, 1994). The data were statistically analysed using SPPS-11, 5 program. The aim of the study was to assess the efficacy of outreach and needle exchange programs in terms of reduction of HIV risk behavior of injection drug users in Tbilisi. The results of the study show visible reduction in injection risk behavior for clients being in the program for at least three months. There was not seen any significant change in the level of sexual risk behavior, which might suggest the need for targeting this behavior during the further interventions. The results of the study suggest a visible potential benefit to drug users and communities that could be gained through the wide scale implementation of harm reduction programs in Georgia.

  17. Harmonizing disease prevention and police practice in the implementation of HIV prevention programs: Up-stream strategies from Wilmington, Delaware

    PubMed Central

    2012-01-01

    Introduction Improving access to sterile injection equipment is a key component in community-based infectious disease prevention. Implementation of syringe access programs has sometimes been complicated by community opposition and police interference. Case description In 2006, the Delaware legislature authorized a pilot syringe exchange program (SEP). A program designed to prevent, monitor, and respond to possible policing and community barriers before they had a chance to effect program implementation and operation. A program designed to prevent, monitor, and respond to these barriers was planned and implemented by a multidisciplinary team of legal practitioners and public health professionals. Discussion We report on an integrated intervention to address structural barriers to syringe exchange program utilization. This intervention employs community, police and client education combined with systematic surveillance of and rapid response to police interference to preempt the kinds of structural barriers to implementation observed elsewhere. The intervention addresses community concerns and stresses the benefits of syringe exchange programs to officer occupational safety. Conclusions A cohesive effort combining collaboration with and educational outreach to police and community members based on the needs and concerns of these groups as well as SEP clients and potential clients helped establish a supportive street environment for the SEP. Police-driven structural barriers to implementation of public health programs targeting populations engaged in drug use and other illicit behavior can be addressed by up-stream planning, prevention, monitoring and intervention strategies. More research is needed to inform the tailoring of interventions to address police-driven barriers to HIV prevention services, especially among marginalized populations. PMID:22591836

  18. Pharmacy syringe purchase test of nonprescription syringe sales in San Francisco and Los Angeles in 2010.

    PubMed

    Lutnick, Alexandra; Cooper, Erin; Dodson, Chaka; Bluthenthal, Ricky; Kral, Alex H

    2013-04-01

    The two main legal sources of clean needles for illicit injection drug users (IDUs) in California are syringe exchange programs (SEPs) and nonprescription syringe sales (NPSS) at pharmacies. In 2004, California became one of the last states to allow NPSS. To evaluate the implementation of NPSS and the California Disease Prevention Demonstration Project (DPDP), we conducted syringe purchase tests in San Francisco (SF) and Los Angeles (LA) between March and July of 2010. Large differences in implementation were observed in the two cities. In LA, less than one-quarter of the enrolled pharmacies sold syringes to our research assistant (RA), and none sold a single syringe. The rate of successful purchase in LA is the lowest reported in any syringe purchase test. In both sites, there was notable variation among the gauge size available, and price and quantity of syringes required for a purchase. None of the DPDP pharmacies in LA or SF provided the requisite health information. The findings suggest that more outreach needs to be conducted with pharmacists and pharmacy staff. The pharmacies' failure to disseminate the educational materials may result in missed opportunities to provide needed harm reduction information to IDUs. The varied prices and required quantities may serve as a barrier to syringe access among IDUs. Future research needs to examine reasons why pharmacies do not provide the mandated information, whether the omission of disposal options is indicative of pharmacies' reluctance to serve as disposal sites, and if the dual opt-in approach of NPSS/DPDP is a barrier to pharmacy enrollment.

  19. Portable system of programmable syringe pump with potentiometer for determination of promethazine in pharmaceutical applications.

    PubMed

    Saleh, Tawfik A; Abulkibash, A M; Ibrahim, Atta E

    2012-04-01

    A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective.

  20. Primary and Secondary Analysis of Local Elected Officials’ Decisions to Support or Oppose Pharmacy Sale of Syringes in California

    PubMed Central

    Rose, Valerie J.

    2010-01-01

    Under California law, local governments may authorize pharmacies within their jurisdictions to sell ten or fewer syringes to an adult without prescription, proof of identity, or proof of medical need. Local governments may simultaneously exempt adults from prosecution for violation of state drug paraphernalia codes for possession of ten or fewer syringes for personal use. Both of these provisions are temporary and sunset on December 31, 2010, unless subsequent state legislation amends that date. The objective of our study was to ascertain how and why local policymakers made their decisions regarding non-prescription syringe sale (NPSS). We examined influences on their decisions, including specific messengers and the arguments that were most salient to their decision making. We selected jurisdictions that were geographically representative of California counties; those with and without syringe exchange programs, and those that had passed or rejected NPSS. We conducted nine semi-structured interviews in five jurisdictions. To enrich primary data collection, we analyzed secondary data by reviewing audio, video, and written transcripts of public hearings and newspaper coverage in five jurisdictions, including three jurisdictions without primary interview data. Among proponents of NPSS, we identified common themes, including: (1) public health research provided conclusive evidence for reduction in HIV and hepatitis transmission without problems of crime, drug use, or unsafe discard of syringes; (2) the local health officer was the key to influencing local policymakers; (3) recall of prior debates over syringe exchange served to inform their decision making; and (4) a lack of local opposition or controversy. Common concerns among opponents of NPSS included: (1) that there would be an increase in unsafe discard of syringes; (2) loss of an important law enforcement tool; (3) that drug users were incapable of desired behavior change; and (4) that research was inconclusive, or proved that syringe access would not work in reducing rates of disease. Themes held in common by proponents and opponents of NPSS were identified as well. Syringe access through NPSS is in fact supported by a robust body of public health research and is considered an important component of a comprehensive strategy to reduce HIV and hepatitis transmission. Our study highlights the importance of understanding the perspectives of elected officials in order to ameliorate their concerns without undermining the public health goal of reducing death, disease, and suffering in at-risk communities. PMID:20352356

  1. The evidence does not speak for itself: The role of research evidence in shaping policy change for the implementation of publicly funded syringe exchange programs in three US cities.

    PubMed

    Allen, Sean T; Ruiz, Monica S; O'Rourke, Allison

    2015-07-01

    A breadth of literature exists that explores the utilization of research evidence in policy change processes. From this work, a number of studies suggest research evidence is applied to change processes by policy change stakeholders primarily through instrumental, conceptual, and/or symbolic applications, or is not used at all. Despite the expansiveness of research on policy change processes, a deficit exists in understanding the role of research evidence during change processes related to the implementation of structural interventions for HIV prevention among injection drug users (IDU). This study examined the role of research evidence in policy change processes for the implementation of publicly funded syringe exchange services in three US cities: Baltimore, MD, Philadelphia, PA, and Washington, DC. In-depth qualitative interviews were conducted with key stakeholders (n=29) from each of the study cities. Stakeholders were asked about the historical, social, political, and scientific contexts in their city during the policy change process. Interviews were transcribed and analyzed for common themes pertaining to applications of research evidence. In Baltimore and Philadelphia, the typological approaches (instrumental and symbolic/conceptual, respectively) to the applications of research evidence used by harm reduction proponents contributed to the momentum for securing policy change for the implementation of syringe exchange services. Applications of research evidence were less successful in DC because policymakers had differing ideas about the implications of syringe exchange program implementation and because opponents of policy change used evidence incorrectly or not at all in policy change discussions. Typological applications of research evidence are useful for understanding policy change processes, but their efficacy falls short when sociopolitical factors complicate legislative processes. Advocates for harm reduction may benefit from understanding how to effectively integrate research evidence into policy change processes in ways that confront the myriad of factors that influence policy change. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  2. The Association Between Law Enforcement Encounters and Syringe Sharing Among IDUs on Skid Row: A Mixed Methods Analysis

    PubMed Central

    Simon-Freeman, Rebecca; Bluthenthal, Ricky N.

    2013-01-01

    The legal environment is one factor that influences injection drug users' (IDUs) risk for HIV and other bloodborne pathogens such as hepatitis C virus (HCV). We examined the association between law enforcement encounters (i.e., arrests and citations) and receptive syringe sharing among IDUs in the context of an intensified policing effort. We conducted a mixed methods analysis of 30 qualitative and 187 quantitative interviews with IDUs accessing services at a Los Angeles, CA syringe exchange program from 2008 to 2009. Qualitative findings illustrate concerns related to visibility, drug withdrawal, and previous history of arrest/incarceration. In quantitative analysis, the number of citations received, current homelessness, and perceiving that being arrested would be a “big problem” were independently associated with recent syringe sharing. Findings illustrate some of the unintended public health consequences associated with intensified street-level policing, including risk for HIV and HCV transmission. PMID:23620243

  3. A sophisticated programmable miniaturised pump for insulin delivery.

    PubMed

    Klein, J C; Slama, G

    1980-09-01

    We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.

  4. High dead-space syringe use among people who inject drugs in Tijuana, Mexico.

    PubMed

    Rafful, Claudia; Zule, William; González-Zúñiga, Patricia E; Werb, Dan; Medina-Mora, María Elena; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2015-05-01

    High dead-space syringes (HDSS) are believed to confer an elevated risk of acquiring HIV and other blood-borne infections. We identified prevalence and correlates of HDSS use among injection drug users (IDU) in Tijuana, Mexico, where syringe purchase and possession is legal without a prescription. Beginning in 2011, IDU who reported being 18 years or older and injected drugs within the last month were recruited into a prospective study. At baseline and semi-annually, 557 IDU underwent HIV-testing and interviewer-administered surveys. Logistic regression was used to identify correlates of using HDSS. Of 557 IDU, 40% had ever used HDSS, mostly because no other syringe type was available (72%), or because they were easier to get (20%). Controlling for sex and age at first injection, use of HDSS was associated with cocaine as the first drug injected (Adjusted Odds Ratio [AOR]: 2.68; Confidence Interval 95% [CI]: 1.15-6.22), having been stopped or arrested by police (AOR: 1.84; 95% CI: 1.11-3.07), being deported from the US (AOR: 1.64; 95% CI:1.06-2.53), and believing it is illegal to carry syringes (AOR:1.78; 95% CI: 1.01-3.15). Use of HDSS is surprisingly common among IDU in Tijuana. Efforts are needed to expand coverage of low-dead space syringes through existing syringe exchange programs. Education is required to increase awareness of the harms associated with HDSS, and to inform IDU that syringe possession is legal across Mexico.

  5. Portable system of programmable syringe pump with potentiometer for determination of promethazine in pharmaceutical applications

    PubMed Central

    Saleh, Tawfik A.; Abulkibash, A.M.; Ibrahim, Atta E.

    2011-01-01

    A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective. PMID:23960787

  6. Syringe Access, Syringe Sharing, and Police Encounters among People Who Inject Drugs in New York City: A Community-Level Perspective

    PubMed Central

    Beletsky, Leo; Heller, Daliah; Jenness, Samuel M.; Neaigus, Alan; Gelpi-Acosta, Camila; Hagan, Holly

    2013-01-01

    Background Injection drug user (IDU) experience and perceptions of police practices may alter syringe exchange program (SEP) use or influence risky behaviour. Previously, no community-level data had been collected to identify the prevalence or correlates of police encounters reported by IDUs in the United States. Methods New York City IDUs recruited through respondent-driven sampling were asked about past-year police encounters and risk behaviours, as part of the National HIV Behavioural Surveillance study. Data were analysed using multiple logistic regression. Results A majority (52%) of respondents (n=514) reported being stopped by police officers; 10% reported syringe confiscation. In multivariate modelling, IDUs reporting police stops were less likely to use SEPs consistently (adjusted odds ratio [AOR]=0.59; 95% confidence interval [CI]=0.40–0.89), and IDUs who had syringes confiscated may have been more likely to share syringes (AOR=1.76; 95% CI=0.90–3.44), though the finding did not reach statistical significance. Conclusions Findings suggest that police encounters may influence consistent SEP use. The frequency of IDU-police encounters highlights the importance of including contextual and structural measures in infectious disease risk surveillance, and the need to develop approaches harmonizing structural policing and public health. PMID:23916801

  7. Making a difference? Applying Vitellone's Social Science of the Syringe to performance and image enhancing drug injecting.

    PubMed

    Hart, Aaron

    2018-04-18

    Vitellone's Social Science of the Syringe investigates epistemologies of injecting drug use. She argues for a methodology that can be simultaneously sensitive to biopolitical power regimes; the trajectories of social stratification; and the resistance, creativity and dignity of human agency. She proposes a methodological focus on the syringe-in-use as an active participant in these dynamics. Harm reduction policy and service provision frameworks have paid little attention to the phenomena of performance and image enhancing drug (PIEDs) injection. One way of assessing the merit of Vitellone's proposal is to use it to investigate these phenomena. I argue that Vitellone's method can be used to articulate a range of significant differences between people who inject PIEDs and other people who inject drugs, and that these differences can inform harm reduction initiatives. When compared to the heroin syringe, the PIED syringe participates in different socio-economic and material contexts, gendered identities, and biopolitical governance regimes. These differences materialise in different rates of syringe sharing and blood-borne virus transmission; and different experiences of needle exchange services. I offer a thought experiment demonstrating how a different syringe might alter the structural dynamics, biopolitical governance, and the agentic choices of people who inject PIEDs. Judging by the productive effects of diffracting Vitellone's analysis through an empirical concern with PIED injecting, I concur with Vitellone's proposition that 'something objective may be gained from an empirical investigation of the syringe-in-use' (p. 33). Copyright © 2018 Elsevier B.V. All rights reserved.

  8. High dead-space syringe use among people who inject drugs in Tijuana, Mexico

    PubMed Central

    Rafful, Claudia; Zule, William; González-Zúñiga, Patricia E.; Werb, Dan; Elena Medina-Mora, María; Magis-Rodriguez, Carlos; Strathdee, Steffanie A.

    2015-01-01

    Background High dead-space syringes (HDSS) are believed to confer an elevated risk of acquiring HIV and other blood-borne infections. Objectives We identified prevalence and correlates of HDSS use among injection drug users (IDU) in Tijuana, Mexico, where syringe purchase and possession is legal without a prescription. Methods Beginning in 2011, IDU who reported being 18 years or older, who injected drugs within the last month were recruited into a prospective study. At baseline and semi-annually, 557 IDU underwent HIV-testing and interviewer-administered surveys. Logistic regression was used to identify correlates of using HDSS. Results Of 557 IDU, 40% had ever used HDSS, mostly because no other syringe type was available (72%), or because they were easier to get (20%). Controlling for sex and age at first injection, use of HDSS was associated with cocaine as the first drug injected (Adjusted Odds Ratio [AOR]:2.68; Confidence Interval 95% [CI]:1.15-6.22), having been stopped or arrested by police (AOR:1.84; 95% CI:1.11-3.07), being deported from the US (AOR:1.64; 95%CI:1.06-2.53), and believing it is illegal to carry syringes (AOR:1.78; 95%CI:1.01-3.15). Conclusion Use of HDSS is surprisingly common among IDU in Tijuana. Efforts are needed to expand coverage of low-dead space syringes through existing syringe exchange programs. Education is required to increase awareness of the harms associated with HDSS, and to inform IDU that syringe possession is legal across Mexico. PMID:25695145

  9. Impact of monetary incentives on adherence to referral for screening chest x-rays after syringe exchange-based tuberculin skin testing.

    PubMed

    Perlman, David C; Friedmann, Patricia; Horn, Leslie; Nugent, Anne; Schoeb, Veronika; Carey, Jeanne; Salomon, Nadim; Des Jarlais, Don C

    2003-09-01

    Syringe-exchange programs (SEPs) have proven to be valuable sites to conduct tuberculin skin testing among active injection drug users. Chest x-rays (CXRs) are needed to exclude active tuberculosis prior to initiating treatment for latent tuberculosis infection. Adherence of drug users to referral for off-site chest x-rays has been incomplete. Previous cost modeling demonstrated that a monetary incentive to promote adherence could be justified on the cost basis if it had even a modest effect on adherence. We compared adherence to referral for chest x-rays among injection drug users undergoing syringe exchange-based tuberculosis screening in New York City before and after the implementation of monetary incentives. From 1995 to 1998, there were 119 IDUs referred for CXRs based on tuberculin skin testing at the SEP. From 1999 to 2001, there were 58 IDUs referred for CXRs with a $25 incentive based on adherence. Adherence to CXR referral within 7 days was 46/58 (79%) among individuals who received the monetary incentive versus 17/119 (14%) prior to the implementation of the monetary incentive (P<.0001; odds ratio [OR]=23; 95% confidence interval [CI]=9.5-57). The median time to obtaining a CXR was significantly shorter among those given the incentive than among those referred without the incentive (2 vs. 11 days, P<.0001). In multivariate logistic regression analysis, use of the incentive was highly independently associated with increased adherence (OR=22.9; 95% CI=10-52). Monetary incentives are highly effective in increasing adherence to referral for screening CXRs to exclude active tuberculosis after syringe exchange-based tuberculin skin testing. Prior cost modeling demonstrated that monetary incentives could be justified on the cost basis if they had even a modest effect on adherence. The current data demonstrated that monetary incentives are highly effective at increasing adherence in this setting and therefore are justifiable on a cost basis. When health care interventions for drug users require referral off site, monetary incentives may be particularly valuable in promoting adherence.

  10. Pharmacy staff characteristics associated with support for pharmacy-based HIV-testing in pharmacies participating in the New York State Expanded Access Syringe Exchange Program

    PubMed Central

    Amesty, Silvia; Blaney, Shannon; Crawford, Natalie D.; Rivera, Alexis V.; Fuller, Crystal

    2013-01-01

    Objective To determine support of in-pharmacy HIV-testing among pharmacy staff and the individual-level characteristics associated with in-pharmacy HIV testing support. Design Descriptive, nonexperimental, cross-sectional study. Setting New York City (NYC) during January 2008 to March 2009. Intervention 131 pharmacies registered in the Expanded Syringe Access Program (ESAP) completed a survey. Participants 480 pharmacy staff, including pharmacists, owners/managers, and technicians/clerks. Main outcome measures Support of in-pharmacy HIV testing. Results Support of in-pharmacy HIV testing is high among pharmacy staff (79.4%). Pharmacy staff that supported in-pharmacy vaccinations were significantly more likely to support in-pharmacy HIV testing. Pharmacy staff that think that selling syringes to IDUs causes the community to be littered with dirty syringes were significantly less likely to support in-pharmacy HIV testing. Conclusion Support for in-pharmacy HIV testing is high among our sample of ESAP pharmacy staff actively involved in non-prescription syringe sales. These findings suggest that active ESAP pharmacy staff may be amenable to providing HIV counseling and testing to injection drug users and warrants further investigation. PMID:22825227

  11. Injecting drugs in tight spaces: HIV, cocaine and collinearity in the Downtown Eastside, Vancouver, Canada.

    PubMed

    Ciccarone, Daniel; Bourgois, Philippe

    2016-07-01

    This commentary revisits the political turmoil and scientific controversy over epidemiological study findings linking high HIV seroincidence to syringe exchange attendance in Vancouver in the mid-1990s. The association was mobilized polemically by US politicians and hard-line drug warriors to attack needle exchange policies and funding. In turn, program restrictions limiting access to syringes at the Vancouver exchange may have interfaced with a complex conjunction of historical, geographic, political economic and cultural forces and physiological vulnerabilities to create an extraordinary HIV risk environment: (1) ghettoization of services for indigent populations in a rapidly gentrifying, post-industrial city; (2) rural-urban migration of vulnerable populations subject to historical colonization and current patterns of racism; and (3) the flooding of North America with inexpensive powder cocaine and heroin, and the popularity of crack. In fact, we will never know with certainty the precise cause for the extreme seroincidence rates in Vancouver in the early to mid-1990s. The tendency for modern social epidemiology to decontextualize research subjects and assign excessive importance to discrete, "magic bullet" variables resulted in a counterproductive scientific and political debate in the late 1990s that has obfuscated potentially useful practical lessons for organizing the logistics of harm reduction services - especially syringe exchange - to better serve the needs of vulnerable populations and to mitigate the effects of political-economically imposed HIV risk environments. We would benefit from humbly acknowledging the limits of public health science and learn to recognize the unintended consequences of well-intentioned interventions rather than sweep embarrassing histories under the rug. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Development of a programmable piggyback syringe pump and four-times-a-day injection regimen for superovulation in non-lactating Holstein cows

    PubMed Central

    IRSHAD, Abdul Razaq; SASAKI, Taihei; KUBO, Tomoaki; ODASHIMA, Naoyuki; KATANO, Keiji; OSAWA, Takeshi; TAKAHASHI, Toru; IZAIKE, Yoshiaki

    2015-01-01

    The objectives of the present study were to develop a programmable piggyback syringe pump for bovine superovulation and to evaluate the effects of a four-times-a-day injection regimen using the pump. Non-lactating Holstein cows were treated with a total of 30 armour units of porcine FSH by injection four times a day with the pump (study, n = 9) or injection twice a day manually (control, n = 9) for four consecutive days from D10 of the estrous cycle. The pump-driven program successfully induced superovulation in all cows tested. The numbers of small (3– < 5 mm in diameter) and large (≥ 10 mm in diameter) follicles were greater in the study group on D11-13 and D14, respectively. There were fewer unovulated follicles detected on D21 (7 days after estrus) in the study group than in the control group (1.2 ± 0.4 and 3.2 ± 0.6, respectively). PMID:26052155

  13. Development of a programmable piggyback syringe pump and four-times-a-day injection regimen for superovulation in non-lactating Holstein cows.

    PubMed

    Irshad, Abdul Razaq; Sasaki, Taihei; Kubo, Tomoaki; Odashima, Naoyuki; Katano, Keiji; Osawa, Takeshi; Takahashi, Toru; Izaike, Yoshiaki

    2015-01-01

    The objectives of the present study were to develop a programmable piggyback syringe pump for bovine superovulation and to evaluate the effects of a four-times-a-day injection regimen using the pump. Non-lactating Holstein cows were treated with a total of 30 armour units of porcine FSH by injection four times a day with the pump (study, n = 9) or injection twice a day manually (control, n = 9) for four consecutive days from D10 of the estrous cycle. The pump-driven program successfully induced superovulation in all cows tested. The numbers of small (3- < 5 mm in diameter) and large (≥ 10 mm in diameter) follicles were greater in the study group on D11-13 and D14, respectively. There were fewer unovulated follicles detected on D21 (7 days after estrus) in the study group than in the control group (1.2 ± 0.4 and 3.2 ± 0.6, respectively).

  14. Behavioural change in injecting drug users: evaluation of an HIV/AIDS education programme.

    PubMed

    Martin, G S; Serpelloni, G; Galvan, U; Rizzetto, A; Gomma, M; Morgante, S; Rezza, G

    1990-01-01

    The results obtained from the training and follow-up of 189 IDUs who participated in a programme consisting of an audiovisual presentation, pre-/post-testing and individual counselling are presented. Syringe sharing decreased from 35% at initial contact to 12% after 6 months. Sexual behaviour proved more resistant to change. However, condom use in at-risk situations increased from 49% to 70%. IDUs under continuous methadone treatment were less likely to engage high risk drug injecting practices than the other IDUs. Results indicate that an educational programme addressed toward risk reduction may determine relevant behavioural change among IDUs.

  15. The New York Needle Trial: the politics of public health in the age of AIDS.

    PubMed Central

    Anderson, W

    1991-01-01

    During the past 5 years, the exchange of sterile needles and syringes for dirty injecting equipment has gained increasing acceptance outside the United States as a potential means of reducing the transmission of the human immunodeficiency virus (HIV) among intravenous drug users. This article describes the controversy over attempts to establish a needle and syringe exchange scheme in New York City between 1985 and 1991. The response to a health crisis is used as an indicator of patterns of social and institutional practice. Advocates of needle exchanges had reached a stalemate with the promoters of law enforcement, and the strategic reformulation of the policy problem in terms of the research process seemed to offer a solution. The article discusses the practical limitations on designing and carrying out a controversial health promotion policy; the use (under constraint) of a restrictive research process to constitute--rather than simply to guide or monitor--public policy; and the potential ethical hazards of health professionals' seeking a polemical recourse to the clinical trial. The efforts to establish a needle exchange in New York thus illustrate more general problems for AIDS prevention. Images p1511-a p1512-a p1513-a PMID:1951815

  16. Low-cost feedback-controlled syringe pressure pumps for microfluidics applications.

    PubMed

    Lake, John R; Heyde, Keith C; Ruder, Warren C

    2017-01-01

    Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips.

  17. Low-cost feedback-controlled syringe pressure pumps for microfluidics applications

    PubMed Central

    Lake, John R.; Heyde, Keith C.

    2017-01-01

    Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips. PMID:28369134

  18. High risk behaviors of injection drug users registered with harm reduction programme in Karachi, Pakistan

    PubMed Central

    Altaf, Arshad; Shah, Sharaf Ali; Zaidi, Najam A; Memon, Ashraf; Nadeem-ur-Rehman; Wray, Norman

    2007-01-01

    Background Surveillance data of Sindh AIDS Control Programme, Pakistan suggest that HIV infection is rapidly increasing among IDUs in Karachi and has reached 9% in 2004–5 indicating that the country has progressed from nascent to concentrated level of HIV epidemic. Findings of 2nd generation surveillance in 2004–5 also indicate 104/395 (26.3%) IDUs HIV positive in the city. Methods We conducted a cross sectional study among registered IDUs of a needle exchange and harm reduction programme in Karachi, Pakistan. A total of 161 IDUs were included in the study between October–November 2003. A detailed questionnaire was implemented and blood samples were collected for HIV, hepatitis B & C and syphilis. HIV, hepatitis B and C antibody tests were performed using Enzyme Linked Immunosorbent Assay (ELISA) method. Syphilis tests (RPR & TPHA) were performed on Randox kit. Besides calculating frequencies univariate analysis was performed using t tests for continuous variables as age, age at first intercourse and average age of initiation of addiction and chi square for categorical variables like paid for sex or not to identify risk factors for hepatitis B and C and syphilis. Results Average age of IDU was 35.9 years and average age of initiation of drugs was 15.9 years. Number of drug injections per day was 2.3. Shooting drugs in group sharing syringes was reported by 128 (79.5%) IDUs. Over half 94 (58.3%) reported paying for sex and 64% reported never using a condom. Commercial selling of blood was reported by 44 (28%). 1 of 161 was HIV positive (0.6%). The prevalence of hepatitis B was 12 (7.5%), hepatitis C 151 (94.3%) and syphilis 21 (13.1%). IDUs who were hepatitis C positive were more likely to start sexual activity at an earlier age and had never used condoms. Similarly IDUs who were hepatitis B positive were more likely to belong to a younger age group. Syphilis positive IDUs were more likely to have paid for sex and had never used a condom. Conclusion Prudent measures such as access to sterile syringes, rehabilitation and opiate substitution therapies are required to reduce high risk behaviors of IDUs in Pakistan. PMID:17291354

  19. Patterns of sexual commerce among women at US Syringe Exchange Programs.

    PubMed

    Braine, Naomi; Desjarlais, Don C; Goldblatt, Cullen; Zadoretzky, Cathy; Turner, Charles

    2006-01-01

    In the USA, the majority of research on sex work has examined the experiences of women recruited from social locations commonly referred to as the 'sex industry', such as street strolls or escort services. This paper presents data from female syringe exchange participants who had sold sex in the last 30 days. The women interviewed for this study report a much broader array of commercial transactions than found in previous US studies, including selling sex to women, paying men for sex, and considerable role fluidity between buying and selling. In addition, approximately one-third of the women report only selling sex 1 day per week or less, and appear to be more socio-economically stable than women who sell sex more often. We argue that this data suggests the existence of an array of commercial sexual transactions outside of the socially recognized sex industry, and that social location may affect condom use.

  20. Quantifying Syringe Exchange Program Operational Space in the District of Columbia.

    PubMed

    Allen, Sean T; Ruiz, Monica S; Jones, Jeff

    2016-12-01

    Syringe exchange programs (SEPs) are effective structural interventions for HIV prevention among persons who inject drugs. In 2000, a buffer zone policy (the 1000 Foot Rule) was implemented in Washington, DC, that prohibited SEP operations within 1000 feet of schools. We examined changes in the amount of legal SEP operational space over time. We used data pertaining to school operations and their approximate physical property boundaries to quantify the impact of the 1000 Foot Rule on legal SEP operational space from its implementation in 2000-2013. Adherence to the 1000 Foot Rule reduced SEP operational space by more than 50 % annually since its implementation. These findings demonstrate the significant restrictions on the amount of legal SEP operational space in Washington, DC, that are imposed by the 1000 Foot Rule. Changing this policy could have a significant impact on SEP service delivery among injectors.

  1. NIMBY localism and national inequitable exclusion alliances: The case of syringe exchange programs in the United States

    PubMed Central

    Tempalski, Barbara; Friedman, Risa; Keem, Marie; Cooper, Hannah; Friedman, Samuel R.

    2007-01-01

    Syringe exchange programs (SEPs) aim to reduce the harm associated with injection drug use (IDU). Although they have been accepted as critical components of HIV prevention in many parts of the world, they are often unwelcome and difficult to set up and maintain, even in communities hardest hit by IDU-related HIV transmission. This research examines socio-cultural and political processes that shape community and institutional resistance toward establishing and maintaining SEPs. These processes are configured and reinforced through the socio-spatial stigmatizing of IDUs, and legal and public policy against SEPs. Overarching themes the paper considers are: (1) institutional and/or political opposition based on (a) political and law enforcement issues associated with state drug paraphernalia laws and local syringe laws; (b) harassment of drug users and resistance to services for drug users by local politicians and police; and (c) state and local government (in)action or opposition; and (2) the stigmatization of drug users and location of SEPs in local neighborhoods and business districts. Rather than be explained by “not in my back yard” localism, this pattern seems best conceptualized as an “inequitable exclusion alliance” (IEA) that institutionalizes national and local stigmatizing of drug users and other vulnerable populations. PMID:18978931

  2. Biotechnology

    NASA Image and Video Library

    2003-05-05

    Aboard the International Space Station (ISS), the Tissue Culture Medium (TCM) is the bioreactor vessel in which cell cultures are grown. With its two syringe ports, it is much like a bag used to administer intravenous fluid, except it allows gas exchange needed for life. The TCM contains cell culture medium, and when frozen cells are flown to the ISS, they are thawed and introduced to the TCM through the syringe ports. In the Cellular Biotechnology Operations Support System-Fluid Dynamics Investigation (CBOSS-FDI) experiment, several mixing procedures are being assessed to determine which method achieves the most uniform mixing of growing cells and culture medium.

  3. Injecting Drugs in Tight Spaces: HIV, Cocaine and Collinearity in the Downtown Eastside, Vancouver, BC

    PubMed Central

    Ciccarone, Daniel; Bourgois, Philippe

    2016-01-01

    This commentary revisits the political turmoil and scientific controversy over epidemiological study findings linking high HIV seroincidence to syringe exchange attendance in Vancouver in the mid-1990s. The association was mobilized polemically by US politicians and hard-line drug warriors to attack needle exchange policies and funding. In turn, program restrictions limiting access to syringes at the Vancouver exchange may have interfaced with a complex conjunction of historical, geographic, political economic and cultural forces and physiological vulnerabilities to create an extraordinary HIV risk environment: 1) ghettoization of services for indigent populations in a rapidly gentrifying, post-industrial city; 2) rural-urban migration of vulnerable populations subject to historical colonization and current patterns of racism; and 3) the flooding of North America with inexpensive powder cocaine and heroin, and the popularity of crack. In fact, we will never know with certainty the precise cause for the extreme seroincidence rates in Vancouver in the early to mid-1990s. The tendency for modern social epidemiology to decontextualize research subjects and assign excessive importance to discrete, “magic bullet” variables resulted in a counterproductive scientific and political debate in the late 1990s that has obfuscated potentially useful practical lessons for organizing the logistics of harm reduction services–especially syringe exchange–to better serve the needs of vulnerable populations and to mitigate the effects of political-economically imposed HIV risk environments. We would benefit from humbly acknowledging the limits of public health science and learn to recognize the unintended consequences of well-intentioned interventions rather than sweep embarrassing histories under the rug. PMID:27117187

  4. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    PubMed

    Treloar, Carla; McCredie, Luke; Lloyd, Andrew R

    2016-01-01

    A formal Needle and Syringe Program (NSP) is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV) risk and risk mitigation opportunities for inmates. The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons. A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison) and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment) "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison. The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  5. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    PubMed Central

    Treloar, Carla; McCredie, Luke; Lloyd, Andrew R.

    2016-01-01

    Aim A formal Needle and Syringe Program (NSP) is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV) risk and risk mitigation opportunities for inmates. Method The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons. Results A needle/syringe was nominated as being typically priced in the ‘inside’ prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison) and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment) “quiet”, stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison. Conclusions The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices. PMID:27611849

  6. Preconditioning of mesenchymal stromal cells toward nucleus pulposus-like cells by microcryogels-based 3D cell culture and syringe-based pressure loading system.

    PubMed

    Zeng, Yang; Feng, Siyu; Liu, Wei; Fu, Qinyouen; Li, Yaqian; Li, Xiaokang; Chen, Chun; Huang, Chenyu; Ge, Zigang; Du, Yanan

    2017-04-01

    To precondition mesenchymal stromal/stem cells (MSCs) with mechanical stimulation may enhance cell survival and functions following implantation in load bearing environment such as nucleus pulposus (NP) in intervertebral disc (IVD). In this study, preconditioning of MSCs toward NP-like cells was achieved in previously developed poly (ethylene glycol) diacrylate (PEGDA) microcryogels (PMs) within a syringe-based three-dimensional (3D) culture system which provided a facile and cost-effective pressure loading approach. PMs loaded with alginate and MSCs could be incubated in a sealable syringe which could be air-compressed to apply pressure loading through a programmable syringe pump. Expression levels of chondrogenic marker genes SOX9, COL II, and ACAN were significantly upregulated in MSCs when pressure loading of 0.2 MPa or 0.8 MPa was implemented. Expression levels of COL I and COL X were downregulated when pressure loading was applied. In a nude mouse model, MSCs loaded in PMs mechanically stimulated for three days were subcutaneously injected using the same culture syringe. Three weeks postinjection, more proteoglycans (PGs) were deposited and more SOX9 and COL II but less COL I and COL X were stained in 0.2 MPa group. Furthermore, injectable MSCs-loaded PMs were utilized in an ex vivo rabbit IVD organ culture model that demonstrated the leak-proof function and enhanced cell retention of PMs assisted cell delivery to a load bearing environment for potential NP regeneration. This microcryogels-based 3D cell culture and syringe-based pressure loading system represents a novel method for 3D cell culture with mechanical stimulation for better function. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 507-520, 2017. © 2015 Wiley Periodicals, Inc.

  7. Cellular Biotechnology Operations Support System Fluid Dynamics Investigation

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Aboard the International Space Station (ISS), the Tissue Culture Medium (TCM) is the bioreactor vessel in which cell cultures are grown. With its two syringe ports, it is much like a bag used to administer intravenous fluid, except it allows gas exchange needed for life. The TCM contains cell culture medium, and when frozen cells are flown to the ISS, they are thawed and introduced to the TCM through the syringe ports. In the Cellular Biotechnology Operations Support System-Fluid Dynamics Investigation (CBOSS-FDI) experiment, several mixing procedures are being assessed to determine which method achieves the most uniform mixing of growing cells and culture medium.

  8. [Harm reduction interventions in drug users: current situation and recommendations].

    PubMed

    Bosque-Prous, Marina; Brugal, María Teresa

    2016-11-01

    Harm reduction encompasses interventions, programmes and policies that seek to reduce the negative consequences of the consumption of both legal and illegal drugs on the individual and public health. Harm reduction looks to mitigate the harm suffered by drug users through drug use monitoring and prevention, and promotes initiatives that respect and protect the human rights of this population. The harm reduction policies that have proven effective and efficient are: opioid substitution maintenance therapy (methadone); needle and syringe exchange programmes; supervised drug consumption rooms; and overdose prevention through peer-based naloxone distribution. In order to be effective, these policies must have comprehensive coverage and be implemented in areas where the target population is prevalent. Resident-based opposition to the implementation of these policies is known as the NIMBY (Not In My Back Yard) phenomenon, which is characterised by being against the implementation of new measures in a particular place, but does not question their usefulness. Given that any NIMBY phenomenon is a complex social, cultural and political phenomenon, it is important to conduct a thorough analysis of the situation prior to implementing any of these measures. Harm reduction policies must be extended to other substances such as alcohol and tobacco, as well as to other conditions beyond infectious/contagious diseases and overdose. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. A student's analysis of the Moi University-Linköping University exchange programme.

    PubMed

    Mwenda, A S

    2012-11-01

    Introduction : Moi University College of Health Sciences was established in 1989. It is comprised of the schools of medicine, nursing, public health and dentistry. Since its inception, the college has been in collaboration with Linköping University in Sweden. This collaboration has taken the form of student and staff exchanges, as well as infrastructure and library improvements. This study was carried out to analyse the exchange programme and highlight some of the strengths that the exchange programme brings to the students' academic experience. Methods : A qualitative cross-sectional survey was conducted among the students who participated in the elective/exchange programme in the years 2009, 2010 and 2011. Self-administered questionnaires were completed by the participants. Additional data were obtained from the recommendations and conclusions from the reports that the students wrote after their participation in the exchange programme. Focus group discussions and key informant interviews were also carried out. Results : A total of 46 students participated in the exchange programme: 27 from Moi University and 19 from Linköping University. The disciplines of students reflected the undergraduate courses offered by these universities. The exchange programme's strengths were exposing students to new cultural settings, different healthcare system organisation and influencing future academic and personal lives, as well as making education global. The main challenge facing the exchange programme was language. Discussion : This study shows the exchange programme as a strong pillar of the medical education curriculum, enabling students to get a global perspective on their education, while exposing them to significant cultural and healthcare organisation diversity. There is a need to expand the collaboration so that more students have the opportunity to experience the overseas exchange programme.

  10. Australian Universities' Strategic Goals of Student Exchange and Participation Rates in Outbound Exchange Programmes

    ERIC Educational Resources Information Center

    Daly, Amanda; Barker, Michelle

    2010-01-01

    International student exchange programmes are acknowledged as one aspect of a broader suite of internationalisation strategies aimed at enhancing students' intercultural understanding and competence. The decision to participate in an exchange programme is dependent on both individual and contextual factors such as student exchange policies and…

  11. An observation of lower rates of drug use over time in community syringe exchangers.

    PubMed

    Kidorf, Michael; King, Van L; Peirce, Jessica; Kolodner, Ken; Brooner, Robert K

    2013-01-01

    The present study evaluated changes in rates of self-reported heroin and cocaine use in opioid-dependent individuals newly registered to a syringe exchange program (SEP), and examined the effects of recovery-oriented longitudinal variables (i.e., substance abuse treatment, self-help group participation, employment) on changes in drug use. Study participants (n = 240) were opioid-dependent and drawn from a larger study evaluating strategies to improve treatment-seeking. Mixed model analyses were used to evaluate changes in rates of heroin and cocaine use, and longitudinal correlates of change in these substances, over a one-year period. Results showed reductions in days of heroin and cocaine use over time, and that participation in recovery-oriented activities was strongly associated with greater changes in drug use. These results suggest SEPs can play a vital role in facilitating reductions in drug use through motivating participation in treatment and other recovery-oriented activities. Copyright © American Academy of Addiction Psychiatry.

  12. Characterization of Antimicrobial Agent Loaded Eudragit RS Solvent Exchange-Induced In Situ Forming Gels for Periodontitis Treatment.

    PubMed

    Phaechamud, Thawatchai; Jantadee, Takron; Mahadlek, Jongjan; Charoensuksai, Purin; Pichayakorn, Wiwat

    2017-02-01

    Eudragit RS (ERS), a quaternary polyacrylate positively charged polymer, exhibits a very low permeability and swells in aqueous media independently of pH without dissolving. Owing to its high solubility in N-methyl pyrrolidone (NMP), it was interesting to apply as polymer matrix for solvent-exchanged in situ forming gel. The aim of this research was to prepare in situ forming gels from ERS to deliver the antimicrobial agents (doxycycline hyclate, metronidazole, and benzoyl peroxide) for periodontitis treatment. They were evaluated for viscosity and rheology, gel formation, syringeability, drug release, and antimicrobial activities. The solvent exchange between NMP and an external aqueous simulated gingival crevicular fluid stimulated the dissolved ERS transforming into the opaque rigid gel. Antimicrobial agent loaded ERS systems exhibited Newtonian flow with acceptable syringeability. The higher-loaded ERS promoted the more prolongation of drug release because of the retardation of water diffusion into the precipitated matrix. Antimicrobial activities against Staphylococcus aureus, Escherichia coli, Candida albicans, Streptococcus mutans, and Porphyromonas gingivalis depended on type of drugs and test microorganisms. Doxycycline hyclate loaded ERS systems showed these activities greater than the others; however, all of them could inhibit all test microorganisms. Thus, the solvent exchange-induced in situ forming gels comprising ERS-antimicrobial drugs exhibited potential use as localized delivery systems for periodontitis treatment.

  13. Negotiating access: Social barriers to purchasing syringes at pharmacies in Tijuana, Mexico

    PubMed Central

    Davidson, Peter J.; Lozada, Remedios; Rosen, Perth C.; Macias, Armando; Gallardo, Manuel; Pollini, Robin A.

    2012-01-01

    Background One common public health response to the emergence of HIV has been the provision of sterile syringes to people who inject drugs. In Mexico specialized syringe exchanges are rare, and the sale of needles through pharmacies is often the only way people who inject drugs can obtain sterile syringes. However, people who inject drugs in Tijuana, Mexico report considerable social barriers to successfully purchasing syringes at pharmacies. Methods Between October 2008 and March 2009 we conducted seven in-depth focus groups with 47 people who inject drugs in Tijuana, Mexico. Focus group transcripts were analysed using a descriptive and thematic approach rooted in grounded theory. Results We found that injectors offered a number of explanations for why pharmacies were reluctant to sell them syringes, including fear of police; attitudes toward drug use; fear of stereotypical drug user behaviour such as petty theft, violence, or distressing behaviour; and related fears that an obvious drug using clientèle would drive away other customers. Injectors described a range of ways of attempting to re-frame or negotiate interactions with pharmacy staff so that these and related concerns were ameliorated. These included tactics as simple as borrowing cleaner clothing, through to strategies for becoming ‘known’ to pharmacy staff as an individual rather than as a member of a stigmatized group. Conclusion Increasing the ability of pharmacy staff and people who inject drugs to successfully negotiate syringe sales are highly desirable. Interventions designed to improve this likelihood need to capitalize on existing solutions developed ad-hoc by people who inject drugs and pharmacy staff, and should focus on broadening the range of ‘identities’ which pharmacy staff are able to accept as legitimate customers. Approaches to achieve this end might include sensitizing pharmacy staff to the needs of people who inject drugs; facilitating individual drug users meeting individual pharmacy staff; and working with drug users to reduce behaviours seen as problematic by pharmacy staff. PMID:22676968

  14. Negotiating access: social barriers to purchasing syringes at pharmacies in Tijuana, Mexico.

    PubMed

    Davidson, Peter J; Lozada, Remedios; Rosen, Perth C; Macias, Armando; Gallardo, Manuel; Pollini, Robin A

    2012-07-01

    One common public health response to the emergence of HIV has been the provision of sterile syringes to people who inject drugs. In Mexico specialized syringe exchanges are rare, and the sale of needles through pharmacies is often the only way people who inject drugs can obtain sterile syringes. However, people who inject drugs in Tijuana, Mexico report considerable social barriers to successfully purchasing syringes at pharmacies. Between October 2008 and March 2009 we conducted seven in-depth focus groups with 47 people who inject drugs in Tijuana, Mexico. Focus group transcripts were analysed using a descriptive and thematic approach rooted in grounded theory. We found that injectors offered a number of explanations for why pharmacies were reluctant to sell them syringes, including fear of police; attitudes toward drug use; fear of stereotypical drug user behaviour such as petty theft, violence, or distressing behaviour; and related fears that an obvious drug using clientèle would drive away other customers. Injectors described a range of ways of attempting to re-frame or negotiate interactions with pharmacy staff so that these and related concerns were ameliorated. These included tactics as simple as borrowing cleaner clothing, through to strategies for becoming 'known' to pharmacy staff as an individual rather than as a member of a stigmatized group. Increasing the ability of pharmacy staff and people who inject drugs to successfully negotiate syringe sales are highly desirable. Interventions designed to improve this likelihood need to capitalize on existing solutions developed ad hoc by people who inject drugs and pharmacy staff, and should focus on broadening the range of 'identities' which pharmacy staff are able to accept as legitimate customers. Approaches to achieve this end might include sensitizing pharmacy staff to the needs of people who inject drugs; facilitating individual drug users meeting individual pharmacy staff; and working with drug users to reduce behaviours seen as problematic by pharmacy staff. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. A randomized trial to evaluate the efficacy of a computer-tailored intervention to promote safer injection practices among drug users.

    PubMed

    Gagnon, Hélène; Godin, Gaston; Alary, Michel; Bruneau, Julie; Otis, Joanne

    2010-06-01

    The aim of this study was to evaluate the efficacy of a theory-based intervention to increase the use of a new syringe for each injection among injection drug users (IDUs). Users of two needle exchange programs (NEPs) were involved. At both sites, participants were assigned at random to either the experimental or the control group. Once a week for four weeks, users reported to the NEPs where they logged onto a computer and received an audiovisual message. A total of 260 IDUs were recruited. At baseline, 52.3% of participants reported that they had not always used new syringes in the previous week. The results indicate that it is possible for IDUs to adopt safer injection practices. One month after the intervention began, participants in the experimental group were using fewer dirty syringes compared to the control group (RR: 0.47 CI(95%) 0.28-0.79; P = .004). This short-term effect was no longer present 3 months later.

  16. Prevalence and correlates of psychological distress among drug users in Phnom Penh, Cambodia.

    PubMed

    Yi, Siyan; Tuot, Sovannary; Chhoun, Pheak; Pal, Khuondyla; Choub, Sok Chamreun; Mburu, Gitau

    2016-10-01

    Compared to the general population, drug users are at increased risk of both poor mental health and HIV infection. The aim of this study was to determine the prevalence and correlates of high psychological distress among drug users in Cambodia. In April 2014, a two-stage cluster sampling method was used to randomly select 169 drug users from hotspots in Phnom Penh. Psychological distress was measured using General Health Questionnaire (GHQ-12). Bivariate and multivariable analyses were conducted to identify factors associated with levels of psychological distress among this population. Our study found high prevalence of attempted suicide (15.3%), drug related arrests (46.2%), and incarceration (31.4%). Of the 169 participants, 42.0% were found to have high levels of psychological distress, indicating poor mental health. After adjustment, high levels of psychological distress were independently associated with suicidal ideation (p<0.001), higher frequency of drug use (p=0.02), sharing of needles or syringes (p=0.005), and having been sent to a rehabilitation centre (p=0.02). In addition, participants who perceived their overall health as being poor or very poor were more likely to have high levels of psychological distress (p=0.002). Integration of mental health within HIV and needle and syringe exchange programmes is required to address psychological distress among drug users in Cambodia. Health system interventions, such as screening, referral, and training of health providers, need to be strengthened. In addition, interventions addressing social determinants of mental health and mitigation of frequent arrests and improving conditions in rehabilitation centres are required. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. [Evaluation of the prevalence of HIV infection in prison inmates at the time of their imprisonment during the period 1991-1995].

    PubMed

    Martín Sánchez, V; Caylá Buqueras, J A; González Morís, M L; Herrero Alonso, L E; Vicente Pérez, R

    1997-01-01

    Inmates of Spanish prisons include a high number of intravenous drug users (IVDUs) and other people whose practices entail the risk of infection with the human immunodeficiency virus (HIV). The aim of this work is to find out the evolution of the prevalence of HIV infection at the time of admission to prison and the factors associated with it in this population group. This may enable us to form an idea of the effectiveness of risk reduction strategies and help to improve them. All those people who were placed in a provincial penal institution in the northwest of Spain between 1991 and 1995. Socio-demographic, penal and HIV risk factor variables were gathered. The HIV infection test (ELISA and Western-blot) was carried out with the consent of the subjects. Of the 1,663 people studied, 19.4% were HIV-positive. The prevalence HIV infection was particularly marked statistically in: women (26.0%), the 25-34 age group (29.1%), whites (20.9%), single people (22.8%), those people with a tattoo (29.9%), those people with a background in self-inflicted injuries (42.2%), IVDUs (46.3%), those who admitted sharing syringes (61.5%) and those with a prison record of one or more years (37.3%). Logistical regression analysis showed the following as predictors of HIV infection: IVDUs, those who went to prison in 1992, women, the 25-34 and 35-44 age group, tattooed men, those with a background in self-inflicted injuries and those with a prison record, of more than one year. The gypsy ethnic group revealed a lower probability of HIV infection. The HIV infection time trend, stratified according to the prison record showed an almost significant drop (P = 0.064). The infection trend per IVDU did not show any modification (P = 0.16). A high prevalence of HIV infection was detected in a prison located in a region which has not been particularly affected by AIDS. IVDUs and some characteristics that may be related to this population group have an enormous influence on this phenomenon. The time trend for this infection in this population group has decreased through the lower number of IVDUs that are admitted to prison although very high levels of prevalence of the infection were maintained in this group over the five years of the study. It is recommended that risk-reduction programmes in prisons be fostered (methadone maintenance programmes, syringe exchange pilot programmes).

  18. Assessing the role of syringe dispensing machines and mobile van outlets in reaching hard-to-reach and high-risk groups of injecting drug users (IDUs): a review

    PubMed Central

    Islam, Md Mofizul; Conigrave, Katherine M

    2007-01-01

    Reaching hard-to-reach and high-risk injecting drug users (IDUs) is one of the most important challenges for contemporary needle syringe programs (NSPs). The aim of this review is to examine, based upon the available international experience, the effectiveness of syringe vending machines and mobile van/bus based NSPs in making services more accessible to these hard-to-reach and high-risk groups of IDUs. A literature search revealed 40 papers/reports, of which 18 were on dispensing machines (including vending and exchange machines) and 22 on mobile vans. The findings demonstrate that syringe dispensing machines and mobile vans are promising modalities of NSPs, which can make services more accessible to the target group and in particular to the harder-to-reach and higher-risk groups of IDUs. Their anonymous and confidential approaches make services attractive, accessible and acceptable to these groups. These two outlets were found to be complementary to each other and to other modes of NSPs. Services through dispensing machines and mobile vans in strategically important sites are crucial elements in continuing efforts in reducing the spread of HIV and other blood borne viruses among IDUs. PMID:17958894

  19. The association between neighborhood socioeconomic disadvantage and high-risk injection behavior among people who inject drugs.

    PubMed

    DeCuir, Jennifer; Lovasi, Gina S; El-Sayed, Abdulrahman; Lewis, Crystal Fuller

    2018-02-01

    Although much research has been conducted on the determinants of HIV risk behavior among people who inject drugs (PWID), the influence of the neighborhood context on high-risk injection behavior remains understudied. To address this gap in the literature, we measured associations between neighborhood socioeconomic disadvantage and high-risk injection behavior, and determined whether these associations were modified by drug-related police activity and syringe exchange program (SEP) accessibility. Our sample was comprised of 484 pharmacy-recruited PWID in New York City. Measures of neighborhood socioeconomic disadvantage were created using data from the 2006-2010 American Community Survey. Associations with high-risk injection behavior were estimated using multivariable Poisson regression. Effect modification by drug-related police activity and SEP accessibility was assessed by entering cross-product terms into adjusted models of high-risk injection behavior. Neighborhood socioeconomic disadvantage was associated with decreased receptive syringe sharing and unsterile syringe use. In neighborhoods with high drug-related police activity, associations between neighborhood disadvantage and unsterile syringe use were attenuated to the null. In neighborhoods with high SEP accessibility, neighborhood disadvantage was associated with decreased acquisition of syringes from an unsafe source. PWID in disadvantaged neighborhoods reported safer injection behaviors than their counterparts in neighborhoods that were relatively better off. The contrasting patterns of effect modification by SEP accessibility and drug-related police activity support the use of harm reduction approaches over law enforcement-based strategies for the control of blood borne virus transmission among PWID in disadvantaged urban areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Public support for safe consumption sites and syringe services programs to combat the opioid epidemic.

    PubMed

    McGinty, Emma E; Barry, Colleen L; Stone, Elizabeth M; Niederdeppe, Jeff; Kennedy-Hendricks, Alene; Linden, Sarah; Sherman, Susan G

    2018-06-01

    We examine Americans' support for two evidence-based harm reduction strategies - safe consumption sites and syringe exchange programs - and their attitudes about individuals who use opioids. We conducted a web-based survey of a nationally representative sample of U.S. adults in July-August 2017 (N = 1004). We measured respondents' support for legalizing safe consumption sites and syringe services programs in their communities and their attitudes toward people who use opioids. We used ordered logistic regression to assess how stigmatizing attitudes toward people who use opioids, political party identification, and demographic characteristics correlated with support for the two harm reduction strategies. Twenty-nine percent of Americans supported legalizing safe consumption sites and 39% supported legalizing syringe services programs. Respondents reported high levels of stigmatizing attitudes toward people who use opioids: 16% of respondents were willing to have a person using opioids marry into their family and 28% were willing to have a person using opioids start working closely with them on a job, and 27% and 10% of respondents rated persons who use opioids as deserving (versus worthless) and strong (versus weak). Stigmatizing attitudes were associated with lower support for legalizing safe consumption sites and syringe services programs. Democrats and Independents were more likely than Republicans to support both strategies. Stigmatizing attitudes toward people who use opioids are a key modifiable barrier to garnering the public support needed to fully implement evidence-based harm reduction strategies to combat the opioid epidemic. Dissemination and evaluation of stigma reduction campaigns are a public health priority. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Integrated lab-in-syringe platform incorporating a membraneless gas-liquid separator for automatic cold vapor atomic absorption spectrometry.

    PubMed

    Giakisikli, Georgia; Miró, Manuel; Anthemidis, Aristidis

    2013-10-01

    This manuscript reports the proof-of-concept of a novel integrated lab-in-syringe/gas-liquid separation (LIS/GLS) batch-flow system based on a programmable flow for automatic cold vapor atomic absorption spectrometric assays. Homogeneous mixing of metered volumes of sample and reagent solutions drawn up in a sandwich-type mode along with in situ vapor generation are accomplished inside the microsyringe in a closed manner, while the separation of vapor species is achieved via the membraneless GLS located at the top of the syringe's valve in the upright position. The potentials of the proposed manifold were demonstrated for trace inorganic mercury determination in drinking waters and seawater. For a 3.0 mL sample, the limit of detection and repeatability (RSD) were found to be 0.03 μg L(-1) Hg(II) and 3.1% (at the 2.0 μg L(-1) concentration level), respectively, with a dynamic range extending up to 10.0 μg L(-1). The proposed system fulfills the requirements of US-EPA, WHO, and EU Council Directives for measurements of the maximum allowed concentrations of inorganic mercury in drinking water.

  2. Seroprevalence of HCV and HIV infection among clients of the nation's longest-standing statewide syringe exchange program: A cross-sectional study of Community Health Outreach Work to Prevent AIDS (CHOW).

    PubMed

    Salek, Thomas P; Katz, Alan R; Lenze, Stacy M; Lusk, Heather M; Li, Dongmei; Des Jarlais, Don C

    2017-10-01

    The Community Health Outreach Work to Prevent AIDS (CHOW) Project is the first and longest-standing statewide integrated and funded needle and syringe exchange program (SEP) in the US. Initiated on O'ahu in 1990, CHOW expanded statewide in 1993. The purpose of this study is to estimate the prevalences of hepatitis C virus (HCV) and human immunodeficiency virus (HIV) infection, and to characterize risk behaviors associated with infection among clients of a long-standing SEP through the analysis of the 2012 CHOW evaluation data. A cross-sectional sample of 130 CHOW Project clients was selected from January 1, 2012 through December 31, 2012. Questionnaires captured self-reported exposure information. HIV and HCV antibodies were detected via rapid, point-of-care FDA-approved tests. Log-binomial regressions were used to estimate prevalence proportion ratios (PPRs). A piecewise linear log-binomial regression model containing 1 spline knot was used to fit the age-HCV relationship. The estimated seroprevalence of HCV was 67.7% (95% confidence interval [CI]=59.5-75.8%). HIV seroprevalence was 2.3% (95% CI=0-4.9%). Anti-HCV prevalence demonstrated age-specific patterns, ranging from 31.6% through 90.9% in people who inject drugs (PWID) <30 to ≥60 years respectively. Age (continuous/year) prior to spline knot at 51.5 years (adjusted PPR [APPR]=1.03; 95% CI=1.02-1.05) and months exchanging syringes (quartiles) (APPR=1.92; 95% CI=1.3-3.29) were independently associated with anti-HCV prevalence. In Hawai'i, HCV prevalence among PWID is hyperendemic demonstrating age- and SEP duration-specific trends. Relatively low HIV prevalence compared with HCV prevalence reflects differences in transmissibility of these 2 blood-borne pathogens and suggests much greater efficacy of SEP for HIV prevention. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The Impact of Foreign Policy on Educational Exchange: The Swedish State Scholarship Programme 1938-1990

    ERIC Educational Resources Information Center

    Åkerlund, Andreas

    2014-01-01

    Programmes of international educational exchange are not only carried out for educational purposes, but form an important part of modern-day public diplomacy. Through exchange programmes education and research are linked with foreign policy interests, which then in turn should affect the international contacts of universities and research…

  4. The provision of non-needle/syringe drug injecting paraphernalia in the primary prevention of HCV among IDU: a systematic review.

    PubMed

    Gillies, Michelle; Palmateer, Norah; Hutchinson, Sharon; Ahmed, Syed; Taylor, Avril; Goldberg, David

    2010-11-23

    Sharing drug injecting paraphernalia other than needles and syringes (N/S) has been implicated in the transmission of Hepatitis C virus (HCV) among injecting drug users (IDU). We aimed to determine whether the provision of sterile non-N/S injecting paraphernalia reduces injecting risk behaviours or HCV transmission among IDU. A systematic search of seven databases and the grey literature for articles published January 1989-February 2010 was undertaken. Thirteen studies (twelve observational and one non-randomized uncontrolled pilot intervention) were identified and appraised for study design and quality by two investigators. No studies examined the association between the provision of non-N/S injecting paraphernalia and incident HCV infection. One cross-sectional study found that individuals who frequently, compared to those who infrequently, used sterile cookers and water, were less likely to report prevalent HCV infection. Another found no association between the uptake of sterile non-N/S injecting paraphernalia and self-reported sharing of this paraphernalia. The remaining observational studies used attendance at needle and syringe exchange programmes (NSP) or safer injection facilities (SIF) that provided non-N/S injecting paraphernalia as a proxy measure. Eight studies presented adjusted odds ratios, ranging from 0.3 to 0.9, suggesting a reduced likelihood of self-reported sharing of non-N/S injecting paraphernalia associated with use of NSP or SIF. There was substantial uncertainty associated with these estimates however. Three unadjusted studies reported a reduction in the prevalence of sharing of non-N/S injecting paraphernalia over time among NSP users. Only one study reported an adjusted temporal trend in the prevalence of sharing non-N/S injecting paraphernalia, finding higher rates among non-NSP users than NSP users at each time point, and a greater reduction in sharing among non-NSP than NSP users over time. Study limitations included the use of convenience samples, self-reported exposure and outcome measures, flawed classification of the exposed and unexposed groups, and inadequate adjustment for potential confounding variables. The evidence to demonstrate that the provision of sterile non-N/S injecting paraphernalia reduces HCV transmission or modifies injecting risk behaviours is currently limited by an insufficient volume and quality of studies. Further research is required to inform practice and policy in this area.

  5. Does opioid substitution treatment in prisons reduce injecting-related HIV risk behaviours? A systematic review.

    PubMed

    Larney, Sarah

    2010-02-01

    To review systematically the evidence on opioid substitution treatment (OST) in prisons in reducing injecting-related human immunodeficiency virus (HIV) risk behaviours. Systematic review in accordance with guidelines of the Cochrane Collaboration. Electronic databases were searched to identify studies of prison-based opioid substitution treatment programmes that included assessment of effects of prison OST on injecting drug use, sharing of needles and syringes and HIV incidence. Published data were used to calculate risk ratios for outcomes of interest. Risk ratios were not pooled due to the low number of studies and differences in study designs. Five studies were included in the review. Poor follow-up rates were reported in two studies, and representativeness of the sample was uncertain in the remaining three studies. Compared to inmates in control conditions, for treated inmates the risk of injecting drug use was reduced by 55-75% and risk of needle and syringe sharing was reduced by 47-73%. No study reported a direct effect of prison OST on HIV incidence. There may be a role for OST in preventing HIV transmission in prisons, but methodologically rigorous research addressing this question specifically is required. OST should be implemented in prisons as part of comprehensive HIV prevention programmes that also provide condoms and sterile injecting and tattooing equipment.

  6. [Risk reduction and drug use in detention: study about the detainees of Liancourt Penitentiary].

    PubMed

    Sannier, Olivier; Verfaillie, Florent; Lavielle, Dorothée

    2012-07-01

    The prison population is drug users. Recent debates around the provision of devices to reduce the risks associated with drug use (syringe exchange programs and snort kit) lead us to question local practices of the prison population. An anonymous questionnaire was offered to the prison population of the Liancourt penitentiary. The questions addressed the use of drugs before and during incarceration, knowledge of HIV and B and C hepatitis status, taking an opiate substitution treatment and advice on the implementation of syringe exchange programs and snort kit. A percentage of 54.4 of the prisoners responded to the questionnaire. An amount of 60.1 % of respondents consumed at least one drug before incarceration and 43.6 % of respondents consumed at least one drug during their incarceration. Cannabis was the most consumed drug before and during incarceration. Barely half of respondents reported knowing their HIV and hepatitis B and C status. Over 10 % of respondents said they were interesting in establishing needle exchange programs or snort kit. The prison concentrate drug users and is not a repressive tool of efficient risk reduction. The strategies implemented by the medical unit of Liancourt prison require adaptations that warrant development of health resources. Then, only new tools to reduce risks associated with drug use can be established. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  7. Solvent exchange-induced in situ forming gel comprising ethyl cellulose-antimicrobial drugs.

    PubMed

    Phaechamud, Thawatchai; Mahadlek, Jongjan

    2015-10-15

    Solvent-exchanged in situ forming gel is a drug delivery system which is in sol form before administration. When it contacts with the body fluid, then the water miscible organic solvent dissipates and water penetrates into the system, leading the polymer precipitation as in situ gel at the site of injection. The aim of this research was to study the parameters affecting the gel properties, drug release and antimicrobial activities of the in situ forming gels prepared from ethyl cellulose (EC) dissolved in N-methyl pyrrolidone (NMP) to deliver the antimicrobial agents (doxycycline hyclate, metronidazole and benzyl peroxide) for periodontitis treatment. The gel appearance, pH, viscosity, rheology, syringeability, gel formation, rate of water diffusion into the gels, in vitro degradation, drug release behavior and antimicrobial activities against Staphylococcus aureus, Escherichia coli, Candida albicans, Streptococcus mutans and Porphyrommonas gingivalis were determined. Increasing the amount of EC increased the viscosity of system while still exhibiting Newtonian flow and increased the work of syringeability whereas decreased the releasing of drug. The system transformed into the rigid gel formation after being injected into the simulated gingival crevicular fluid. The developed systems containing 5% w/w antimicrobial agent showed the antimicrobial activities against all test bacteria. Thus the developed solvent exchange-induced in situ forming gels comprising EC-antimicrobial drugs exhibited potential use for periodontitis treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. [Prevalence of indirect sharing of drug-injecting paraphernalia in Galicia, Madrid, Seville and Valencia [Spain

    PubMed

    Bravo, María J; Royuela, Luis; Barrio, Gregorio; Rodríguez-Arenas, María A; de la Fuente, Luis

    2004-01-01

    To study drug-injecting practices, particularly indirect sharing of injecting paraphernalia (ISIP), and sexual risk behavior. We performed a cross-sectional study of 1638 users of needle exchange programs (NEPs). Different types of ISIP were studied: taking diluted drugs in a syringe used by others, placing the needle in a recipient with other used needles, and reusing cleaning liquid previously used by others. The prevalence of injecting with syringes already used by others was 16% in Galicia, 4.7% in Madrid, 17.6% in Seville and 13.2% in Valencia (p < 0.001). With geographical variations, other types of ISIP (Galicia: 32.4%; Madrid: 28.5%; Seville: 42.6%; Valencia: 27.4% -p < 0.001-) were more frequent than injecting with syringes already used by others (Galicia: 32.4%; Madrid: 28.5%; Seville: 42.6%; Valencia: 27.4% -p < 0.001-). The percentage not injecting with syringes used by others but performing ISIP was 21.7%, 25.3%, 28.2% and 18.1% (p < 0.01) respectively. In all geographical areas, sexual risk practices were more prevalent with steady sex partners (68.6%, 72.0%, 77.8%, 72.8% [NS]) than with casual partners (36.6%, 40.9%, 37.9%, 23.9% [NS]). Among injectors with a stable partner, 81.3% in Galicia, 75.9% in Madrid, 86.1% in Seville and 79.7% in Valencia reported that his/her serological status was negative for HIV or was unknown (p < 0.001). ISIP is more prevalent than injection with syringes already used by others. For a substantial percentage of injectors, ISIP is the only risk practice. ISIP and the low use of condoms, particularly with steady partners, could be a contributory factor to the spread of HIV, hepatitis C virus, and hepatitis B virus infection.

  9. Social and structural factors associated with HIV infection among female sex workers who inject drugs in the Mexico-US border region.

    PubMed

    Strathdee, Steffanie A; Lozada, Remedios; Martinez, Gustavo; Vera, Alicia; Rusch, Melanie; Nguyen, Lucie; Pollini, Robin A; Uribe-Salas, Felipe; Beletsky, Leo; Patterson, Thomas L

    2011-04-25

    FSWs who inject drugs (FSW-IDUs) can acquire HIV through high risk sexual and injection behaviors. We studied correlates of HIV infection among FSW-IDUs in northern Mexico, where sex work is quasi-legal and syringes can be legally obtained without a prescription. FSW-IDUs>18 years old who reported injecting drugs and recent unprotected sex with clients in Tijuana and Ciudad Juarez underwent surveys and HIV/STI testing. Logistic regression identified correlates of HIV infection. Of 620 FSW-IDUs, prevalence of HIV, gonorrhea, Chlamydia, trichomonas, syphilis titers ≥1:8, or any of these infections was 5.3%, 4%, 13%, 35%, 10% and 72%, respectively. Compared to other FSW-IDUs, HIV-positive women were more likely to: have syphilis titers ≥1:8 (36% vs. 9%, p<0.001), often/always inject drugs with clients (55% vs. 32%, p = 0.01), and experience confiscation of syringes by police (49% vs. 28%, p = 0.02). Factors independently associated with HIV infection were syphilis titers ≥1:8, often/always injecting with clients and police confiscation of syringes. Women who obtained syringes from NEPs (needle exchange programs) within the last month had lower odds of HIV infection associated with active syphilis, but among non-NEP attenders, the odds of HIV infection associated with active syphilis was significantly elevated. Factors operating in both the micro-social environment (i.e., injecting drugs with clients) and policy environment (i.e., having syringes confiscated by police, attending NEPs) predominated as factors associated with risk of HIV infection, rather than individual-level risk behaviors. Interventions should target unjustified policing practices, clients' risk behaviors and HIV/STI prevention through NEPs.

  10. Social and Structural Factors Associated with HIV Infection among Female Sex Workers Who Inject Drugs in the Mexico-US Border Region

    PubMed Central

    Strathdee, Steffanie A.; Lozada, Remedios; Martinez, Gustavo; Vera, Alicia; Rusch, Melanie; Nguyen, Lucie; Pollini, Robin A.; Uribe-Salas, Felipe; Beletsky, Leo; Patterson, Thomas L.

    2011-01-01

    Background FSWs who inject drugs (FSW-IDUs) can acquire HIV through high risk sexual and injection behaviors. We studied correlates of HIV infection among FSW-IDUs in northern Mexico, where sex work is quasi-legal and syringes can be legally obtained without a prescription. Methods FSW-IDUs>18 years old who reported injecting drugs and recent unprotected sex with clients in Tijuana and Ciudad Juarez underwent surveys and HIV/STI testing. Logistic regression identified correlates of HIV infection. Results Of 620 FSW-IDUs, prevalence of HIV, gonorrhea, Chlamydia, trichomonas, syphilis titers ≥1∶8, or any of these infections was 5.3%, 4%, 13%, 35%, 10% and 72%, respectively. Compared to other FSW-IDUs, HIV-positive women were more likely to: have syphilis titers ≥1∶8 (36% vs. 9%, p<0.001), often/always inject drugs with clients (55% vs. 32%, p = 0.01), and experience confiscation of syringes by police (49% vs. 28%, p = 0.02). Factors independently associated with HIV infection were syphilis titers ≥1∶8, often/always injecting with clients and police confiscation of syringes. Women who obtained syringes from NEPs (needle exchange programs) within the last month had lower odds of HIV infection associated with active syphilis, but among non-NEP attenders, the odds of HIV infection associated with active syphilis was significantly elevated. Conclusions Factors operating in both the micro-social environment (i.e., injecting drugs with clients) and policy environment (i.e., having syringes confiscated by police, attending NEPs) predominated as factors associated with risk of HIV infection, rather than individual-level risk behaviors. Interventions should target unjustified policing practices, clients' risk behaviors and HIV/STI prevention through NEPs. PMID:21541349

  11. Harm reduction programmes in the Asia--Pacific Region.

    PubMed

    Reid, Gary; Devaney, Madonna L; Baldwin, Simon

    2008-01-01

    This paper reports on the public health intervention of harm reduction to address drug use issues in the Asia-Pacific region. It is based on the report 'Situational analysis of illicit drug issues and responses in Asia and the Pacific', commissioned by the Australian National Council on Drugs Asia Pacific Drug Issues Committee. A comprehensive desk-based review based on published and unpublished literature and key informant data. Drug use in the Asia--Pacific region is widespread, resulting in serious adverse health consequences. Needle and syringe programmes are found in some parts of Asia, but not in the six Pacific Island countries reviewed. Outreach and peer education programmes are implemented, but overall appear minor in size and scope. Substitution therapy programmes appear to be entering a new era of acceptance in some parts of Asia. Primary health care specifically for drug users overall is limited. Harm reduction programmes in the Asia--Pacific region are either small in scale or do not exist. Most programmes lack the technical capacity, human resources and a limited scope of operations to respond effectively to the needs of drug users. Governments in this region should be encouraged to endorse evidence-based harm reduction programmes.

  12. Journal of Astonishment--A Tool to Increase Satisfaction with Exchange Programmes

    ERIC Educational Resources Information Center

    Reinhardt, Claus H.; Rosen, Evelyne N.

    2012-01-01

    Many medical students use exchange programmes to enrich their portfolio. However, such a confrontation with reality can be challenging because custom and practice sometimes differ radically between countries. Exchange students post specific peculiarities, as encountered by them abroad, onto the medical exchange website. They can ask for the…

  13. Life After the Ban: An Assessment of US Syringe Exchange Programs’ Attitudes About and Early Experiences With Federal Funding

    PubMed Central

    Martin, Erika G.; Bowman, Sarah E.; Mann, Marita R.; Beletsky, Leo

    2012-01-01

    Objectives. We aimed to determine whether syringe exchange programs (SEPs) currently receive or anticipate pursuing federal funding and barriers to funding applications following the recent removal of the long-standing ban on using federal funds for SEPs. Methods. We conducted a telephone-administered cross-sectional survey of US SEPs. Descriptive statistics summarized responses; bivariate analyses examined differences in pursuing funding and experiencing barriers by program characteristics. Results. Of the 187 SEPs (92.1%) that responded, 90.9% were legally authorized. Three received federal funds and 116 intended to pursue federal funding. Perceived federal funding barriers were common and included availability and accessibility of funds, legal requirements such as written police support, resource capacity to apply and comply with funding regulations, local political and structural organization, and concern around altering program culture. Programs without legal authorization, health department affiliation, large distribution, or comprehensive planning reported more federal funding barriers. Conclusions. Policy implementation gaps appear to render federal support primarily symbolic. In practice, funding opportunities may not be available to all SEPs. Increased technical assistance and legal reform could improve access to federal funds, especially for SEPs with smaller capacity and tenuous local support. PMID:22420810

  14. Life after the ban: an assessment of US syringe exchange programs' attitudes about and early experiences with federal funding.

    PubMed

    Green, Traci C; Martin, Erika G; Bowman, Sarah E; Mann, Marita R; Beletsky, Leo

    2012-05-01

    We aimed to determine whether syringe exchange programs (SEPs) currently receive or anticipate pursuing federal funding and barriers to funding applications following the recent removal of the long-standing ban on using federal funds for SEPs. We conducted a telephone-administered cross-sectional survey of US SEPs. Descriptive statistics summarized responses; bivariate analyses examined differences in pursuing funding and experiencing barriers by program characteristics. Of the 187 SEPs (92.1%) that responded, 90.9% were legally authorized. Three received federal funds and 116 intended to pursue federal funding. Perceived federal funding barriers were common and included availability and accessibility of funds, legal requirements such as written police support, resource capacity to apply and comply with funding regulations, local political and structural organization, and concern around altering program culture. Programs without legal authorization, health department affiliation, large distribution, or comprehensive planning reported more federal funding barriers. Policy implementation gaps appear to render federal support primarily symbolic. In practice, funding opportunities may not be available to all SEPs. Increased technical assistance and legal reform could improve access to federal funds, especially for SEPs with smaller capacity and tenuous local support.

  15. Mediated Cross-Cultural Learning through Exchange in Higher Agricultural Education

    ERIC Educational Resources Information Center

    Wals, Arjen E. J.; Sriskandarajah, Nadarajah

    2010-01-01

    This article reports on the long-term impact of an intensive European Union-Australia student exchange programme that took place in 2004 and 2005. The programme, Learning through Exchange about Agriculture, Food Systems and Environment (LEAFSE), was designed to facilitate exchange of post-graduate students on a pilot scale between four…

  16. Harm reduction in the USA: the research perspective and an archive to David Purchase.

    PubMed

    Des Jarlais, Don C

    2017-07-26

    The history of harm reduction in the USA has led to the development of some of the most important methods for treating persons for drug use disorders, such as methadone and buprenorphine for opiate use disorder. However, there has been fierce political resistance to implementation and scale-up of harm reduction in the USA. This resistance is rooted in historical demonization of particular psychoactive drugs that were associated with stigmatized racial/ethnic groups.With the discovery of acquired immunodeficiency syndrome (AIDS) in 1981, harm reduction became important not only for treating substance use disorders, but for reducing transmission of blood-borne infection. However, within the context of the crack cocaine epidemic in the 1980s, it was very difficult to implement any programs that appeared to "condone" drug use.It was not until the late 1980s that syringe exchange programs began at the state and local level in the USA. With funding primarily from state and local governments and the support of the North American Syringe Exchange Network (NASEN), there are now approximately 200 programs for syringe exchange in the USA. Research has shown that these programs have been extremely effective in reducing human immunodeficiency virus (HIV) transmission among persons who inject drugs (PWID). The programs in the USA also offer many additional services for drug users, including condom distribution, referrals to substance abuse treatment, HIV, hepatitis C virus (HCV), hepatitis B virus (HBV) counseling and testing, overdose education and naloxone distribution to reverse for overdose.Currently, the USA is experiencing an opioid/heroin epidemic, with significant increases in overdose deaths among drug users. Much of this epidemic is occurring in suburban and rural of the country without harm reduction services. The current challenges for harm reduction and harm reduction research involve expansion of services to suburban and rural areas and implementation science on how to effectively and efficiently address HCV transmission and overdose. Most importantly, continued research efforts are needed to reduce the stigma of psychoactive drug use. While political opposition continues, harm reduction activists and researchers have developed a highly effective partnership based on a common core values.

  17. A police education programme to integrate occupational safety and HIV prevention: protocol for a modified stepped-wedge study design with parallel prospective cohorts to assess behavioural outcomes

    PubMed Central

    Strathdee, Steffanie A; Arredondo, Jaime; Rocha, Teresita; Abramovitz, Daniela; Rolon, Maria Luisa; Patiño Mandujano, Efrain; Rangel, Maria Gudelia; Olivarria, Horcasitas Omar; Gaines, Tommi; Patterson, Thomas L; Beletsky, Leo

    2015-01-01

    Introduction Policing practices are key drivers of HIV among people who inject drugs (PWID). This paper describes the protocol for the first study to prospectively examine the impact of a police education programme (PEP) to align law enforcement and HIV prevention. PEPs incorporating HIV prevention (including harm reduction programmes like syringe exchange) have been successfully piloted in several countries but were limited to brief pre–post assessments; the impact of PEPs on policing behaviours and occupational safety is unknown. Objectives Proyecto ESCUDO (SHIELD) aims to evaluate the efficacy of the PEP on uptake of occupational safety procedures, as assessed through the incidence of needle stick injuries (NSIs) (primary outcome) and changes in knowledge of transmission, prevention and treatment of HIV and viral hepatitis; attitudes towards PWID, adverse behaviours that interfere with HIV prevention and protective behaviours (secondary outcomes). Methods/analysis ESCUDO is a hybrid type I design that simultaneously tests an intervention and an implementation strategy. Using a modified stepped-wedge design involving all active duty street-level police officers in Tijuana (N=∼1200), we will administer one 3 h PEP course to groups of 20–50 officers until the entire force is trained. NSI incidence and geocoded arrest data will be assessed from department-wide de-identified data. Of the consenting police officers, a subcohort (N=500) will be randomly sampled from each class to undergo pre-PEP and post-PEP surveys with a semiannual follow-up for 2 years to assess self-reported NSIs, attitudes and behaviour changes. The impact on PWIDs will be externally validated through a parallel cohort of Tijuana PWIDs. Ethics/dissemination Research ethics approval was obtained from the USA and Mexico. Findings will be disseminated through open access to protocol materials through the Law Enforcement and HIV Network. Trial registration number NCT02444403. PMID:26260350

  18. Safer injections following a new national medicine policy in the public sector, Burkina Faso 1995 – 2000

    PubMed Central

    Logez, Sophie; Hutin, Yvan; Somda, Paul; Thuault, Jérôme; Holloway, Kathleen

    2005-01-01

    Background The common failure of health systems to ensure adequate and sufficient supplies of injection devices may have a negative impact on injection safety. We conducted an assessment in April 2001 to determine to which extent an increase in safe injection practices between 1995 and 2000 was related to the increased access to injection devices because of a new essential medicine policy in Burkina Faso. Methods We reviewed outcomes of the new medicine policy implemented in1995. In April 2001, a retrospective programme review assessed the situation between 1995 and 2000. We visited 52 health care facilities where injections had been observed during a 2000 injection safety assessment and their adjacent operational public pharmaceutical depots. Data collection included structured observations of available injection devices and an estimation of the proportion of prescriptions including at least one injection. We interviewed wholesaler managers at national and regional levels on supply of injection devices to public health facilities. Results Fifty of 52 (96%) health care facilities were equipped with a pharmaceutical depot selling syringes and needles, 37 (74%) of which had been established between 1995 and 2000. Of 50 pharmaceutical depots, 96% had single-use 5 ml syringes available. At all facilities, patients were buying syringes and needles out of the depot for their injections prescribed at the dispensary. While injection devices were available in greater quantities, the proportion of prescriptions including at least one injection remained stable between 1995 (26.5 %) and 2000 (23.8 %). Conclusion The implementation of pharmaceutical depots next to public health care facilities increased geographical access to essential medicines and basic supplies, among which syringes and needles, contributing substantially to safer injection practices in the absence of increased use of therapeutic injections. PMID:16364178

  19. Universities, SMEs and Social Capital: Can You Get Too Much of a Good Thing? An Illustrative Analysis of One University's Knowledge Exchange Programme

    ERIC Educational Resources Information Center

    Gordon, Ian

    2016-01-01

    This article explores a university knowledge exchange programme for small and medium-sized enterprise (SME) owner-managers. Specifically, it considers why a programme designed to achieve growth in a group of SMEs through the creation of a network high in social capital may have become a constraint on the programme's effectiveness over a period of…

  20. Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs

    PubMed Central

    Platt, Lucy; Minozzi, Silvia; Reed, Jennifer; Vickerman, Peter; Hagan, Holly; French, Clare; Jordan, Ashly; Degenhardt, Louisa; Hope, Vivian; Hutchinson, Sharon; Maher, Lisa; Palmateer, Norah; Taylor, Avril; Bruneau, Julie; Hickman, Matthew

    2017-01-01

    Background Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs Needle syringe programmes (NSP) and opioid substitution therapy (OST) are the primary interventions to reduce hepatitis C (HCV) transmission in people who inject drugs. There is good evidence for the effectiveness of NSP and OST in reducing injecting risk behaviour and increasing evidence for the effectiveness of OST and NSP in reducing HIV acquisition risk, but the evidence on the effectiveness of NSP and OST for preventing HCV acquisition is weak. Objectives To assess the effects of needle syringe programmes and opioid substitution therapy, alone or in combination, for preventing acquisition of HCV in people who inject drugs. Search methods We searched the Cochrane Drug and Alcohol Register, CENTRAL, the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), MEDLINE, Embase, PsycINFO, Global Health, CINAHL, and the Web of Science up to 16 November 2015. We updated this search in March 2017, but we have not incorporated these results into the review yet. Where observational studies did not report any outcome measure, we asked authors to provide unpublished data. We searched publications of key international agencies and conference abstracts. We reviewed reference lists of all included articles and topic-related systematic reviews for eligible papers. Selection criteria We included prospective and retrospective cohort studies, cross-sectional surveys, case-control studies and randomised controlled trials that measured exposure to NSP and/or OST against no intervention or a reduced exposure and reported HCV incidence as an outcome in people who inject drugs. We defined interventions as current OST (within previous 6 months), lifetime use of OST and high NSP coverage (regular attendance at an NSP or all injections covered by a new needle/syringe) or low NSP coverage (irregular attendance at an NSP or less than 100% of injections covered by a new needle/syringe) compared with no intervention or reduced exposure. Data collection and analysis We followed the standard Cochrane methodological procedures incorporating new methods for classifying risk of bias for observational studies. We described study methods against the following 'Risk of bias' domains: confounding, selection bias, measurement of interventions, departures from intervention, missing data, measurement of outcomes, selection of reported results; and we assigned a judgment (low, moderate, serious, critical, unclear) for each criterion. Main results We identified 28 studies (21 published, 7 unpublished): 13 from North America, 5 from the UK, 4 from continental Europe, 5 from Australia and 1 from China, comprising 1817 incident HCV infections and 8806.95 person-years of follow-up. HCV incidence ranged from 0.09 cases to 42 cases per 100 person-years across the studies. We judged only two studies to be at moderate overall risk of bias, while 17 were at serious risk and 7 were at critical risk; for two unpublished datasets there was insufficient information to assess bias. As none of the intervention effects were generated from RCT evidence, we typically categorised quality as low. We found evidence that current OST reduces the risk of HCV acquisition by 50% (risk ratio (RR) 0.50, 95% confidence interval (CI) 0.40 to 0.63, I2 = 0%, 12 studies across all regions, N = 6361), but the quality of the evidence was low. The intervention effect remained significant in sensitivity analyses that excluded unpublished datasets and papers judged to be at critical risk of bias. We found evidence of differential impact by proportion of female participants in the sample, but not geographical region of study, the main drug used, or history of homelessness or imprisonment among study samples. Overall, we found very low-quality evidence that high NSP coverage did not reduce risk of HCV acquisition (RR 0.79, 95% CI 0.39 to 1.61) with high heterogeneity (I2 = 77%) based on five studies from North America and Europe involving 3530 participants. After stratification by region, high NSP coverage in Europe was associated with a 76% reduction in HCV acquisition risk (RR 0.24, 95% CI 0.09 to 0.62) with less heterogeneity (I2 =0%). We found low-quality evidence of the impact of combined high coverage of NSP and OST, from three studies involving 3241 participants, resulting in a 74% reduction in the risk of HCV acquisition (RR 0.26 95% CI 0.07 to 0.89). Authors' conclusions OST is associated with a reduction in the risk of HCV acquisition, which is strengthened in studies that assess the combination of OST and NSP. There was greater heterogeneity between studies and weaker evidence for the impact of NSP on HCV acquisition. High NSP coverage was associated with a reduction in the risk of HCV acquisition in studies in Europe. Interventions for reducing hepatitis C infection in people who inject drugs Review question We examine research on the effect of needle syringe programmes (NSP) and opioid substitution treatment (OST) in reducing the risk of becoming infected with the hepatitis C virus. Background There are around 114.9 million people living with hepatitis C and 3 to 4 million people newly infected each year. The main risk for becoming infected is sharing used needles/syringes. Almost half the people who inject drugs have hepatitis C. The provision of sterile injecting equipment through NSPs reduces the need for sharing equipment when preparing and injecting drugs. OST is taken orally and reduces frequency of injection and unsafe injecting practices. We examined whether NSP and OST, provided alone or together, are effective in reducing the chances of becoming infected with hepatitis C in people who inject drugs. Search date The evidence is current to November 2015. Study characteristics We identified 28 research studies across Europe, Australia, North America and China. On average across the studies, the rate of new hepatitis C infections per year was 19.0 for every 100 people. Data from 11,070 people who inject drugs who were not infected with hepatitis C at the start of the study were combined in the analysis. Of the sample, 32% were female, 50% injected opioids, 51% injected daily, and 40% had been homeless. Our study was funded by the National Institute of Health Research's (NIHR) Public Health Research Programme, the Health Protection Research Unit in Evaluation of Interventions, and the European Commission Drug Prevention and Information Programme (DIPP), Treatment as Prevention in Europe: Model Projections. Key results Current use of OST (defined as use at the time of survey or within the previous six months) may reduce risk of acquiring hepatitis C by 50%. We are uncertain whether high coverage NSP (defined as regular attendance at an NSP or all injections being covered by a new needle/syringe) reduces the risk of becoming infected with hepatitis C across all studies globally, but there was some evidence from studies in Europe that high NSP coverage may reduce the risk of hepatitis C infection by 76%. The combined use of high coverage NSP with OST may reduce risk of hepatitis C infection by 74%. Quality of the evidence Quality of evidence ranged from moderate to very low because none of the studies used the gold standard design of randomised controlled trials. PMID:28922449

  1. [The effect of colored syringes and a colored sheet on the incidence of syringe swaps during anesthetic management].

    PubMed

    Hirabayashi, Yoshihiro; Kawakami, Takayuki; Suzuki, Hideo; Igarashi, Takashi; Saitoh, Kazuhiko; Seo, Norimasa

    2005-09-01

    Syringe swap is an important problem in anesthetic care, causing harm to patients. We examined the effect of colored syringe and a colored sheet on the incidence of syringe swaps during anesthetic management. We determined the color code. The blue-syringe contains local anesthetics; yellow-syringe, sympathomimetic drugs; and white-syringe with a red label fixed opposite the scale, muscle relaxants. The colored sheet displays the photographs of the syringe with drug name, dose and volume. The colored syringe and colored sheet were supplied for use from February 2004. We compared the incidence of syringe swaps during the period from February 2004 to January 2005 with that from February 2003 to January 2004. Although five syringe swaps were recorded from February 2003 to January 2004, in 5901 procedures, we encountered no syringe swaps from February 2004 to January 2005, in 6078 procedures. The colored syringe and colored sheet significantly decreased the incidence of syringe swaps during anesthetic management (P <0.05). The use of the sheet together with colored syringes can prevent syringe swaps during anesthesia.

  2. Perceptions of genetic testing and genomic medicine among drug users.

    PubMed

    Perlman, David C; Gelpí-Acosta, Camila; Friedman, Samuel R; Jordan, Ashly E; Hagan, Holly

    2015-01-01

    Genetic testing will soon enter care for human immunodeficiency virus (HIV) and hepatitis C virus (HCV), and for addiction. There is a paucity of data on how to disseminate genetic testing into healthcare for marginalized populations. We explored drug users' perceptions of genetic testing. Six focus groups were conducted with 34 drug users recruited from syringe exchange programmes and an HIV clinic between May and June 2012. Individual interviews were conducted with participants reporting previous genetic testing. All participants expressed acceptance of genetic testing to improve care, but most had concerns regarding confidentiality and implications for law enforcement. Most expressed more comfort with genetic testing based on individual considerations rather than testing based on race/ethnicity. Participants expressed comfort with genetic testing in medical care rather than drug treatment settings and when specifically asked permission, with peer support, and given a clear rationale. Although participants understood the potential value of genetic testing, concerns regarding breaches in confidentiality and discrimination may reduce testing willingness. Safeguards against these risks, peer support, and testing in medical settings based on individual factors and with clear rationales provided may be critical in efforts to promote acceptance of genetic testing among drug users. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Social context of needle selling in Baltimore, Maryland.

    PubMed

    Latkin, Carl A; Davey, Melissa A; Hua, Wei

    2006-01-01

    Although much of the debate surrounding the distribution of sterile syringes to injection drug users (IDUs) has focused on needle exchange programs (NEPs), IDUs acquire their syringes from three major sources: NEPs, pharmacies, and secondary exchangers or needle sellers. The purpose of the present study is to examine types and frequencies of social interactions among drug injectors who sell needles, most of which come from NEPs, compared with individuals who do not sell needles. Specifically, we compared engagement in drug-related behaviors, roles in the drug economy, and social network membership. Data were collected as part of the SHIELD study, an HIV prevention intervention targeted at drug users and their social networks (n=910) from February 2001 through September 2003 in Baltimore, Maryland (USA). In this sample, 56 participants reported selling needles. Needle sellers had higher levels of engagement in drug-related social interactions, including using drugs with others, giving or receiving drugs from others, and buying drugs with other users. Participants who sold needles had a significantly higher number of roles in the drug economy. Also, they had more social network members who were injectors, with whom they talked about risky drug behaviors, gave needles to, and shared cookers and bleach with. Compared with nonselling injectors, needle sellers engage in HIV risk-related behaviors, such as injecting daily and sharing injection equipment, more frequently. The study's findings may be useful to determine whether secondary exchangers should be targeted for HIV prevention activities both to reduce their own risk and to diffuse risk reduction information throughout the drug using community.

  4. The effect on syringe performance of fluid storage and repeated use: implications for syringe pumps.

    PubMed

    Capes, D F; Herring, D; Sunderland, V B; McMillan, D; McDonald, C

    1996-01-01

    Syringe stiction has been reported to cause syringe pump malfunction, hence the effect on syringe performance of syringe use and the formulations used in the syringe were investigated. The force required for syringe plunger motion (at 2.5 mm min-1), when filled with soybean oil emulsion (SBOE) and with water, and the extraction of silicone oil from syringes by these fluids, were measured for Primo, Talus and Terumo 10 mL, and Terumo 50 mL syringes. The breakloose, average extrusion and maximum force required to maintain plunger motion increased after storage of SBOE for 7 days in all syringes tested (p < 0.05). The storage of water increased the breakloose force of all syringes, but only increased the maximum force of Talus syringes, and both the average extrusion and maximum forces of Terumo 10 mL syringes. The mechanism for this is most likely swelling of the elastomer of the piston due to sorption of fluid. The force was found to increase logarithmically with repeated syringe use. Electrothermal atomization atomic absorption spectroscopy was used to measure the silicone oil content of syringe extractions. Three extractions were performed: repeated flushing, vigorous washing, and storage for 7 days with occasional agitation. Up to 69.4% of the silicone oil present in the syringes was extracted with both water and SBOE when they were stored or washed. In contrast to water, SBOE also extracted the lubricant when the syringe was filled and flushed immediately. If syringes are refilled, stored filled before use, or used over a prolonged period, particularly with a SBOE formulation, syringe striction may occur during infusion with a syringe pump.

  5. Predicting pharmacy syringe sales to people who inject drugs: Policy, practice and perceptions.

    PubMed

    Meyerson, Beth E; Davis, Alissa; Agley, Jon D; Shannon, David J; Lawrence, Carrie A; Ryder, Priscilla T; Ritchie, Karleen; Gassman, Ruth

    2018-06-01

    Pharmacies have much to contribute to the health of people who inject drugs (PWID) and to community efforts in HIV and hepatitis C (HCV) prevention through syringe access. However, little is known about what predicts pharmacy syringe sales without a prescription. To identify factors predicting pharmacy syringes sales to PWID. A hybrid staggered online survey of 298 Indiana community pharmacists occurred from July-September 2016 measuring pharmacy policy, practice, and pharmacist perceptions about syringe sales to PWID. Separate bivariate logistical regressions were followed by multivariable logistic regression to predict pharmacy syringe sales and pharmacist comfort dispensing syringes to PWID. Half (50.5%) of Indiana pharmacies sold syringes without a prescription to PWID. Pharmacy syringe sales was strongly associated with pharmacist supportive beliefs about syringe access by PWID and their comfort level selling syringes to PWID. Notably, pharmacies located in communities with high rates of opioid overdose mortality were 56% less likely to sell syringes without a prescription than those in communities with lower rates. Pharmacist comfort dispensing syringes was associated with being male, working at a pharmacy that sold syringes to PWID and one that stocked naloxone, having been asked about syringe access by medical providers, and agreement that PWID should be able to buy syringes without a prescription. As communities with high rates of opioid overdose mortality were less likely to have pharmacies that dispensed syringes to PWID, a concerted effort with these communities and their pharmacies should be made to understand opportunities to increase syringe access. Future studies should explore nuances between theoretical support for syringe access by PWID without a prescription and actual dispensing behaviors. Addressing potential policy conflicts and offering continuing education on non-prescription syringe distribution for pharmacists may improve comfort distributing syringes to PWID, and therefore increase pharmacy syringe sales. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Evaluation of an innovative nursing exchange programme: health counselling skills and cultural awareness.

    PubMed

    Lee, Regina L T; Pang, Samantha M C; Wong, Thomas K S; Chan, M F

    2007-11-01

    In 2006, a two-week summer exchange programme was conducted for nursing students from 15 institutes and/or universities, including places in Taiwan, Macau, Chinese mainland and Hong Kong. This paper evaluates a summer exchange programme focusing on nursing students' professional and personal development within the context of learning health counselling skills and studying cultural aspects of the host Region. The programme was evaluated using a mixed method of both quantitative and qualitative research design. Three dimensions include students' exchange perspective, professional development and personal development were evaluated at the end of the two-week programme. Data for this evaluation were derived from the results of questionnaires completed by the 64 nursing students enrolled in this programme, and from the analysis of five focus group interviews. Overall, students (98%) reported that they were very positive about their experiences during the programme, and felt they had gained a greater awareness of effective health counselling skills, of the latest developments in advanced nursing technology within the host School, and of cultural diversity in relation to their personal and professional development. Comparison of sub-total mean scores and standard deviations (mean+/-SD) of the three dimensions among students from Taiwan, Chinese mainland and Hong Kong/Macau, revealing significant differences in the exchange perspective (Taiwan: 18.6+/-1.4; Chinese mainland: 18.8+/-1.4; and Hong Kong/Macau: 16.5+/-1.1) professional development (Taiwan: 18.4+/-1.6; Chinese mainland: 18.2+/-1.5; and Hong Kong/Macau: 16.2+/-2.0) and personal development dimensions (Taiwan: 18.9+/-1.0; Chinese mainland: 18.6+/-1.4; and Hong Kong/Macau: 17.3+/-1.1) among these three places (p<0.001). For paired comparison (post-hoc test), the findings also show that the sub-total mean scores of the students from Taiwan and Chinese mainland were significantly higher than those of students from Hong Kong and Macau in the exchange perspective (Taiwan versus Hong Kong/Macau, p<0.001; Chinese mainland versus Hong Kong/Macau, p<0.001), professional development (Taiwan versus Hong Kong/Macau, p=0.001; Chinese mainland versus Hong Kong/Macau, p<0.001), and personal development (Taiwan versus Hong Kong/Macau, p<0.001; Chinese mainland versus Hong Kong/Macau, p=0.002). Although the findings cannot be generalized, the programme evaluation highlights the positive impact on one's exchange perspective and professional and personal development of a culturally integrated exchange programme for nursing students, with emphasis on skill practices and cultural diversity.

  7. Not sold here: limited access to legally available syringes at pharmacies in Tijuana, Mexico

    PubMed Central

    2011-01-01

    Background Sterile syringe access is a critical component of HIV prevention programs. Although retail pharmacies provide convenient outlets for syringe access, injection drug users (IDUs) may encounter barriers to syringe purchase even where purchase without a prescription is legal. We sought to obtain an objective measure of syringe access in Tijuana, Mexico, where IDUs report being denied or overcharged for syringes at pharmacies. Methods Trained "mystery shoppers" attempted to buy a 1 cc insulin syringe according to a predetermined script at all retail pharmacies in three Tijuana neighborhoods. The same pharmacies were surveyed by telephone regarding their syringe sales policies. Data on purchase attempts were analyzed using basic statistics to obtain an objective measure of syringe access and compared with data on stated sales policies to ascertain consistency. Results Only 46 (28.4%) of 162 syringe purchase attempts were successful. Leading reasons for unsuccessful attempts were being told that the pharmacy didn't sell syringes (35.3%), there were no syringes in stock (31.0%), or a prescription was required (20.7%). Of 136 pharmacies also surveyed by telephone, a majority (88.2%) reported selling syringes but only one-third (32.5%) had a successful mystery shopper purchase; the majority of unsuccessful purchases were attributed to being told the pharmacy didn't sell syringes. There was similar discordance regarding prescription policies: 74 pharmacies said in the telephone survey that they did not require a prescription for syringes, yet 10 of these pharmacies asked the mystery shopper for a prescription. Conclusions IDUs in Tijuana have limited access to syringes through retail pharmacies and policies and practices regarding syringe sales are inconsistent. Reasons for these restrictive and inconsistent practices must be identified and addressed to expand syringe access, reduce syringe sharing and prevent HIV transmission. PMID:21609471

  8. Not sold here: limited access to legally available syringes at pharmacies in Tijuana, Mexico.

    PubMed

    Pollini, Robin A; Rosen, Perth C; Gallardo, Manuel; Robles, Brenda; Brouwer, Kimberly C; Macalino, Grace E; Lozada, Remedios

    2011-05-24

    Sterile syringe access is a critical component of HIV prevention programs. Although retail pharmacies provide convenient outlets for syringe access, injection drug users (IDUs) may encounter barriers to syringe purchase even where purchase without a prescription is legal. We sought to obtain an objective measure of syringe access in Tijuana, Mexico, where IDUs report being denied or overcharged for syringes at pharmacies. Trained "mystery shoppers" attempted to buy a 1 cc insulin syringe according to a predetermined script at all retail pharmacies in three Tijuana neighborhoods. The same pharmacies were surveyed by telephone regarding their syringe sales policies. Data on purchase attempts were analyzed using basic statistics to obtain an objective measure of syringe access and compared with data on stated sales policies to ascertain consistency. Only 46 (28.4%) of 162 syringe purchase attempts were successful. Leading reasons for unsuccessful attempts were being told that the pharmacy didn't sell syringes (35.3%), there were no syringes in stock (31.0%), or a prescription was required (20.7%). Of 136 pharmacies also surveyed by telephone, a majority (88.2%) reported selling syringes but only one-third (32.5%) had a successful mystery shopper purchase; the majority of unsuccessful purchases were attributed to being told the pharmacy didn't sell syringes. There was similar discordance regarding prescription policies: 74 pharmacies said in the telephone survey that they did not require a prescription for syringes, yet 10 of these pharmacies asked the mystery shopper for a prescription. IDUs in Tijuana have limited access to syringes through retail pharmacies and policies and practices regarding syringe sales are inconsistent. Reasons for these restrictive and inconsistent practices must be identified and addressed to expand syringe access, reduce syringe sharing and prevent HIV transmission.

  9. Legal space for syringe exchange programs in hot spots of injection drug use-related crime.

    PubMed

    Allen, Sean T; Ruiz, Monica S; Jones, Jeff; Turner, Monique M

    2016-04-26

    Copious evidence indicates that syringe exchange programs (SEPs) are effective structural interventions for HIV prevention among persons who inject drugs (PWID). The efficacy of SEPs in supporting the public health needs of PWID populations is partially dependent on their accessibility and consistent utilization among injectors. Research has shown that SEP access is an important predictor of PWID retention at SEPs, yet policies exist that may limit the geographic areas where SEP operations may legally occur. Since 2000 in the District of Columbia (DC), SEP operations have been subject to the 1000 Foot Rule (§48-1121), a policy that prohibits the distribution of "any needle or syringe for the hypodermic injection of any illegal drug in any area of the District of Columbia which is within 1000 feet of a public or private elementary or secondary school (including a public charter school)." The 1000 Foot Rule may impede SEP services in areas that are in urgent need for harm reduction services, such as locations where injections are happening in "real time" or where drugs are purchased or exchanged. We examined the effects of the 1000 Foot Rule on SEP operational space in injection drug use (IDU)-related crime (i.e., heroin possession or distribution) hot spots from 2000 to 2010. Data from the DC Metropolitan Police Department were used to identify IDU-related crime hot spots. School operation data were matched to a dataset that described the approximate physical property boundaries of land parcels. A 1000-ft buffer was applied to all school property boundaries. The overlap between the IDU-related crime hot spots and the school buffer zones was calculated by academic year. When overlaying the land space associated with IDU-related crime hot spots on the maps of school boundaries per the 1000-ft buffer zone stipulation, we found that the majority of land space in these locations was ineligible for legal SEP operations. More specifically, the ineligible space in the identified hot spots in each academic year ranged from 51.93 to 88.29 % of the total hot spot area. The removal of the 1000 Foot Rule could significantly improve the public health of PWID via increased access to harm reduction services. Buffer zone policies that restrict SEP operational space negatively affect the provision of harm reduction services to PWID.

  10. Barriers to Pharmacy-Based Syringe Purchase Among Injection Drug Users in Tijuana, Mexico: A Mixed Methods Study

    PubMed Central

    Lozada, Remedios; Gallardo, Manuel; Rosen, Perth; Vera, Alicia; Macias, Armando; Palinkas, Lawrence A.; Strathdee, Steffanie A.

    2010-01-01

    Injection drug users (IDUs) may be denied purchase of sterile syringes even where purchase without a prescription is legal. This study examined barriers to over-the-counter (OTC) syringe purchase among IDUs in Tijuana, Mexico. A quantitative survey and subsequent focus groups were used to quantify barriers to purchase, identify their correlates and provide in-depth exploration of syringe purchase experiences. Of 627 IDUs, 81% purchased a syringe in the past 6 months and 16% were refused or overcharged. Factors independently associated with refusal/overcharging were homelessness, receptive syringe sharing, >5 uses per syringe, and number of lifetime abscesses. Few pharmacies sold syringes to IDUs, who adapted by limiting purchase attempts to pharmacies known to sell syringes consistently. Failed purchases occurred when drug withdrawal required purchase at unusual times or locations, often following release from jail. IDUs reported syringe sharing, syringe reuse, and searching through unsecured medical waste for syringes in response to failed purchase attempts. Interventions to expand OTC syringe sales to IDUs, particularly near detention facilities, will facilitate safer injection practices. PMID:20300820

  11. "It Doesn't Really Matter Which University You Attend or Which Subject You Study While Abroad." The Massification of Student Mobility Programmes and Its Implications for Equality in Higher Education

    ERIC Educational Resources Information Center

    Courtois, Aline

    2018-01-01

    Based on documentary analysis and interviews, the article examines the current practices of Irish universities in their efforts to increase their students' participation in international exchange programmes. It argues that increased participation, while a positive outcome, obscures a growing differentiation in the types of exchange programmes and…

  12. Syringe and needle exchange programs worldwide: Part II.

    PubMed

    Schwartz, R H

    1993-03-01

    The first large-scale syringe and needle exchange (SANE) programs were established in The Netherlands and in the United Kingdom (UK) about 8 years ago. Since then, SANE programs have been established in Australia, Sweden, Canada, and the United States. To date, the most useful data concerning the impact of these programs have come from studies in the UK and from New Haven, San Francisco, Tacoma, and New York City in the US. Successful SANE programs require careful planning; those in charge should be familiar with the accomplishments, problems, and goals of established programs. Advance publicity and involvement of community activists, the local police precinct, and ward or district politicians are imperative for overcoming misunderstandings and prejudices and fostering a team approach. Pilot projects must be adequately funded. Other requirements include accessible facilities, convenient hours of operation (including evening hours), provision of mobile units if at all possible, and provision for sanitary disposal of discarded injection equipment in the neighborhood around the SANE programs. Programs also should have a strong evaluation component, preferably staffed by an independent university-affiliated research center. Periodic site visits are necessary to ensure that services promised in the protocol are actually delivered not only initially, but also over time. Problems with security and drug dealing in and around the building where the SANE program is located are likely, and appropriate measures should be taken to counter them.

  13. Warming of infusion syringes caused by electronic syringe pumps.

    PubMed

    Cornelius, A; Frey, B; Neff, T A; Gerber, A C; Weiss, M

    2003-05-01

    To evaluate inadvertent warming of the infusion syringe in four different types of electronic syringe pumps. Ambient temperature and syringe surface temperature were simultaneously measured by two electronic temperature probes in four different models of commercially available syringe pumps. Experiments were performed at an infusion rate of 1 ml h(-1) using both battery-operated and main power-operated pumps. Measurements were repeated four times with two pumps from each of the four syringe pump types at a room temperature of approximately 23 degrees C. Differences among the four syringe pump brands regarding ambient to syringe temperature gradient were compared using ANOVA. A P-value of less than 0.05 was considered statistically significant. Syringe warming differed significantly between the four syringe brands for both the battery-operated and main power-operated mode (ANOVA, P< 0.001 for both modes). Individual differences between syringe surface and ambient temperature ranged from 0.3 to 1.9 degrees C for battery operation and from 0.5 to 11.2 degrees C during main-power operation. Infusion solutions can be significantly warmed by syringe pumps. This has potential impact on bacterial growth and the stability of drug solutions and blood products infused, as well as on the susceptibility to hydrostatic pressure changes within the infusion syringe.

  14. Access to Sterile Injecting Equipment is More Important Than Awareness of HCV Status for Injection Risk Behaviors Among Drug Users

    PubMed Central

    COX, JOSEPH; MORISSETTE, CAROLE; DE, PRITHWISH; TREMBLAY, CLAUDE; ALLARD, ROBERT; GRAVES, LISA; STEPHENSON, RANDOLPH; ROY, ÉLISE

    2010-01-01

    Awareness of hepatitis C virus (HCV) infection status is expected to influence risk behaviors. In 2004–2005, injection drug users (IDUs) recruited from syringe exchange programs (SEPs) and methadone clinics in Montreal, Canada, were interviewed on drug use behaviors (past 6 months) and HCV testing. Subjects (n = 230) were classified as low/intermediate risk (20.4% borrowed drug preparation equipment only) and high risk (19.6% borrowed syringes), and 54.5% reported being HCV positive. Logistic regression modeling showed that compared to no risk (60% borrowed nothing), low/intermediate risk was associated with fewer noninjecting social network members, poor physical health, and problems obtaining sterile injecting equipment. High risk was associated with all of these factors except social networks. HCV status was not associated with any level of risk. Improved access to sterile injecting equipment may be more important than knowledge of HCV status in reducing injection risks among this IDU population. The study limitations are noted and recommendations discussed. PMID:19242863

  15. Recovering Infectious HIV from Novel Syringe-Needle Combinations with Low Dead Space Volumes.

    PubMed

    Abdala, Nadia; Patel, Amisha; Heimer, Robert

    This study determines if detachable syringe-needle combinations redesigned to reduce their dead space volume may substantially reduce the burden of exposure to infectious HIV among people who inject drugs. Two novel, low dead space (LDS) syringe-needle designs-one added a piston to the plunger (LDS syringe) and the other added a filler to the needle (LDS needle) to reduce their dead space-were compared to standard detachable needle-syringe combinations and to syringes with fixed needles. LDS and standard syringes attached to LDS and standard needles of 23-, 25-, and 27-gauge size were contaminated with HIV-infected blood in the laboratory. The proportion of syringe-needle combinations containing infectious HIV was analyzed after syringes were (1) stored up to 7 days at 22°C or (2) rinsed with water. Detachable syringes attached to 25-gauge needles yielded comparable proportions of syringes with infectious HIV, whether the needle was standard or LDS. Among needles of greater diameter (23 gauge), LDS needles tended to reduce recoverable HIV to a greater extent than standard needles. Syringes with fixed needles showed superior results to LDS syringes attached to needles of equivalent diameter and were less likely to get clogged by blood. Detachable LDS syringe-needle designs must be recommended with caution since they still pose potential risk for HIV transmission. Distribution of LDS syringes and needles must be accompanied by recommendations and instructions for their proper rinsing and disinfection in order to reduce viral burden and chances of needle clogging.

  16. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    PubMed

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting safety-engineered devices for an orthopaedic clinic, conventional syringes larger than 20 mL and conventional needles longer than 1.5 in (3.8 cm) are necessary.

  17. Over-the-counter but out of reach: a pharmacy-based survey of OTC syringe sales in Tijuana, Mexico.

    PubMed

    Pollini, Robin A; Gallardo, Manuel; Ruiz, Serena; Case, Patricia; Zaller, Nickolas; Lozada, Remedios

    2014-05-01

    Sterile syringe access is critical to HIV prevention efforts targeting injection drug users (IDUs) but some pharmacies do not sell syringes over-the-counter (OTC) even where such sales are legal. We conducted a pharmacy survey in Tijuana, Mexico (where OTC sales are legal) to characterize attitudes toward syringe sales and to explore support for expanding pharmacy-based HIV prevention efforts. Of 203 respondents, 28% supported OTC syringe sales to IDUs and 74% said their pharmacy required a prescription for at least some syringe sales. Support for OTC syringe sales was independently associated with selling OTC syringes, understanding the role of sterile syringes in HIV prevention, and recognizing pharmacies as an important health resource for IDUs. Most respondents supported an expanded role for pharmacies in HIV prevention, exclusive of OTC syringe sales. Our study provides information for developing interventions to promote OTC syringe sales and expanding pharmacy-based distribution of HIV-related information and resources.

  18. Exchange programmes and student mobility: meeting student's expectations or an expensive holiday?

    PubMed

    Keogh, Johannes; Russel-Roberts, Eileen

    2009-01-01

    The Bologna Process aims, amongst other things, to improve the mobility of Students within the EU. Student mobility is supported through programmes such as ERASMUS, and the success of these programmes is measured against quality and quantity of Student mobility within the European Union. This study aimed at establishing, from the students' perspective, the benefits of these programmes. To this purpose, 7 Students who were involved in a German-Finnish exchange programme were interviewed. This population was chosen, because they represented the largest group of students going to the same host university, and were influenced by the same variables, such as language difficulties and climatic conditions. The main objective of this study was to determine whether the educational and personal needs of the students were met during their exchange programme. The data analysis was done using Mayring's content analysis method. The results showed that successful mobility at student level, could lead to a diffusion of knowledge and skills between different countries. It was also found that the students indicated that their personal and educational needs were met irrespective of the language difficulties they experienced.

  19. Options for reducing HIV transmission related to the dead space in needles and syringes.

    PubMed

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  20. Logistics management in Universal Immunisation Programme.

    PubMed

    Bachani, D; Bansal, R D

    1990-01-01

    The review of the National Immunization Programme of India in 1989 focused attention to the issue of storage and distribution of vaccines. Cold-chain equipment such as walk-in-coolers (WICs), deep freezers, ice-lined refrigerators (ILRs), and vaccine carriers proliferated after the introduction of the universal immunization program (UIP) but the available units fell short of the official targets in 1988, especially ILRs (7500 proposed and 2876 available) and vaccine carriers (250,000 proposed and 35,500 available). Some states had over 6 months of supplies of vaccines whose management posed problems of losing potency: oral polio virus (OPV) potency was acceptable in 63% of stock in 1988. Syringes, needles, stoves, pressure-cooker sterilizers, dial thermometers, and refrigerator repair kits were in short supply especially at the primary health care (PHC) level. Only 1/3 of subcenters had sterilizers and 58% had vaccines carriers. Logistics management on the state level required provision of vaccines based on previous use and eligible population with even distribution throughout the year. On the district level WICs were needed for every district with 1.5 million inhabitants. Recording of vaccine requirement, utilization, and storage would aid target allocations and avoid wastage. On the institutional and PHC level an ILR and a transporting vehicle was needed. The number of women and children eligible for immunization had to be calculated based on real population figures. Cold-chain capacity of 30,000-40,000 vials was required for a district as well as about 500 reusable syringes and needles a year along with vaccination cards exceeding the number of women and children by 10% for recordkeeping at the PHC center.

  1. Feasibility of reaching world health organization targets for hepatitis C and the cost-effectiveness of alternative strategies.

    PubMed

    Wisløff, T; White, R; Dalgard, O; Amundsen, E J; Meijerink, H; Kløvstad, H

    2018-04-06

    New drugs for treating hepatitis C have considerably increased the probability of being cured. Treatment uptake, however, is still low. The objectives of this study were to analyse the impact of initiatives that may increase the proportion of infected people on treatment and interventions aimed at reducing the incidence of new infection among people who inject drugs. A compartmental model for Norway was used to simulate hepatitis C and related complications. We analysed 2 different screening initiatives aimed to increase the proportion of infected people on treatment. Interventions aiming at reducing the hepatitis C incidence analysed were opioid substitution therapy (OST), a clean needle and syringe programme and a combination of both. The most cost-effective strategy for increasing hepatitis C treatment uptake was screening by general practitioners while simultaneously allowing for all infected people to be treated. We estimated that this intervention reduces the incidence of hepatitis C by 2030 by 63% compared with the current incidence. The 2 harm reduction strategies both reduced the incidence of hepatitis C by about 70%. Combining an increase in the current clean needles and syringe programme with OST was clearly the most cost-effective option. This strategy would reduce the incidence of hepatitis C by 80% compared with the current incidence by 2030. Thus, interventions to reduce the burden and spread of hepatitis C are cost-effective. Reaching the WHO target of a 90% reduction in hepatitis C incidence by 2030 may be difficult without combining different initiatives. © 2018 The Authors. Journal of Viral Hepatitis Published by John Wiley & Sons Ltd.

  2. Disinfection of syringes contaminated with hepatitis C virus by rinsing with household products.

    PubMed

    Binka, Mawuena; Paintsil, Elijah; Patel, Amisha; Lindenbach, Brett D; Heimer, Robert

    2015-01-01

    Background.  Hepatitis C virus (HCV) transmission among people who inject drugs (PWID) is associated with the sharing of injection paraphernalia. People who inject drugs often "disinfect" used syringes with household products when new syringes are unavailable. We assessed the effectiveness of these products in disinfecting HCV-contaminated syringes. Methods.  A genotype-2a reporter virus assay was used to assess HCV infectivity in syringes postrinsing. Hepatitis C virus-contaminated 1 mL insulin syringes with fixed needles and 1 mL tuberculin syringes with detachable needles were rinsed with water, Clorox bleach, hydrogen peroxide, ethanol, isopropanol, Lysol, or Dawn Ultra at different concentrations. Syringes were either immediately tested for viable virus or stored at 4°C, 22°C, and 37°C for up to 21 days before viral infectivity was determined. Results.  Most products tested reduced HCV infectivity to undetectable levels in insulin syringes. Bleach eliminated HCV infectivity in both syringes. Other disinfectants produced virus recovery ranging from high (5% ethanol, 77% ± 12% HCV-positive syringes) to low (1:800 Dawn Ultra, 7% ± 7% positive syringes) in tuberculin syringes. Conclusions.  Household disinfectants tested were more effective in fixed-needle syringes (low residual volume) than in syringes with detachable needles (high residual volume). Bleach was the most effective disinfectant after 1 rinse, whereas other diluted household products required multiple rinses to eliminate HCV. Rinsing with water, 5% ethanol (as in beer), and 20% ethanol (as in fortified wine) was ineffective and should be avoided. Our data suggest that rinsing of syringes with household disinfectants may be an effective tool in preventing HCV transmission in PWID when done properly.

  3. Disinfection of Syringes Contaminated With Hepatitis C Virus by Rinsing With Household Products

    PubMed Central

    Binka, Mawuena; Paintsil, Elijah; Patel, Amisha; Lindenbach, Brett D.; Heimer, Robert

    2015-01-01

    Background. Hepatitis C virus (HCV) transmission among people who inject drugs (PWID) is associated with the sharing of injection paraphernalia. People who inject drugs often “disinfect” used syringes with household products when new syringes are unavailable. We assessed the effectiveness of these products in disinfecting HCV-contaminated syringes. Methods. A genotype-2a reporter virus assay was used to assess HCV infectivity in syringes postrinsing. Hepatitis C virus-contaminated 1 mL insulin syringes with fixed needles and 1 mL tuberculin syringes with detachable needles were rinsed with water, Clorox bleach, hydrogen peroxide, ethanol, isopropanol, Lysol, or Dawn Ultra at different concentrations. Syringes were either immediately tested for viable virus or stored at 4°C, 22°C, and 37°C for up to 21 days before viral infectivity was determined. Results. Most products tested reduced HCV infectivity to undetectable levels in insulin syringes. Bleach eliminated HCV infectivity in both syringes. Other disinfectants produced virus recovery ranging from high (5% ethanol, 77% ± 12% HCV-positive syringes) to low (1:800 Dawn Ultra, 7% ± 7% positive syringes) in tuberculin syringes. Conclusions. Household disinfectants tested were more effective in fixed-needle syringes (low residual volume) than in syringes with detachable needles (high residual volume). Bleach was the most effective disinfectant after 1 rinse, whereas other diluted household products required multiple rinses to eliminate HCV. Rinsing with water, 5% ethanol (as in beer), and 20% ethanol (as in fortified wine) was ineffective and should be avoided. Our data suggest that rinsing of syringes with household disinfectants may be an effective tool in preventing HCV transmission in PWID when done properly. PMID:26034767

  4. Highly controlled vascular syringes for pericardiocentesis.

    PubMed

    Ricciardi, Mark; Roldan, Carlos; Sibbitt, Randy; Sibbitt, Wilmer; Michael, Adrian; Palmer, Dennis

    2010-12-01

    The present study determined the utility and needle control characteristics of highly controlled vascular syringes for image-guided pericardiocentesis. Vascular syringes have been integrated into invasive cardiovascular procedures with improved patient safety, but to date have not been used in pericardiocentesis. To address this issue, we determined the method of use of vascular syringes for pericardiocentesis. A vascular syringe with reciprocating plungers, the reciprocating procedure device (RPD syringe), replaced the corresponding 10 ml and 20 ml conventional syringes in a standard pericardiocentesis tray. The vascular syringe is controlled with one hand, and can either aspirate or inject by pushing the corresponding aspiration or injection plunger. Four hundred and thirty seven subjects underwent vascular syringe procedures. The linear displacement method was used to precisely measure control of the needle tip in millimeters (mm) in vascular syringes compared to conventional syringes in 20 individual operators. Relative to the corresponding 10 ml and 20 ml conventional syringes, vascular syringes significantly reduced unintended forward penetration of the needle tip by 44% (7.0 ± 4.3 mm; p < 0.0001) and 53% (10.1 ± 5.5 mm; p < 0.0001), respectively, and reduced unintended retraction of the needle by 56% (2.7 ± 2.2 mm; p < 0.001) and 60% (3.5 ± 2.5 mm; p < 0.001), respectively. During pericardiocentesis, the mechanical syringe permitted facile one-handed aspiration and maintained the operator's ability to clear the needle. In the 437 vascular syringe procedures, there were no complications, with an estimated cost savings of $10-65 per procedure. Vascular syringes improve needle control in pericardiocentesis, promote patient safety and permit one-handed aspiration and injection.

  5. Enhancing the Intercultural Effectiveness of Exchange Programmes: Formal and Non-Formal Educational Interventions

    ERIC Educational Resources Information Center

    Almeida, Joana; Fantini, Alvino E.; Simões, Ana Raquel; Costa, Nilza

    2016-01-01

    This paper examines how the addition of intercultural interventions carried out throughout European credit-bearing exchange programmes can enhance sojourners' development of intercultural competencies, and it explores how both formal and non-formal pedagogical interventions may be designed and implemented. Such interventions were conducted at a…

  6. Physician control of needle and syringe during aspiration-injection procedures with the new reciprocating syringe.

    PubMed

    Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D

    2006-04-01

    To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.

  7. Syringe Disposal among Injection Drug Users in Harlem and the Bronx during the New York State Expanded Syringe Access Demonstration Program

    ERIC Educational Resources Information Center

    Cleland, Charles M.; Deren, Sherry; Fuller, Crystal M.; Blaney, Shannon; McMahon, James M.; Tortu, Stephanie; Des Jarlais, Don C.; Vlahov, David

    2007-01-01

    Effective January 1, 2001, New York State enacted the Expanded Syringe Access Demonstration Program (ESAP), allowing syringes to be sold in pharmacies without a prescription or dispensed through doctors, hospitals, and clinics to adults. A concern in the assessment of ESAP is its effects on syringe disposal practices. Syringe use data regarding…

  8. How does the use of multiple needles/syringes per injecting episode impact on the measurement of individual level needle and syringe program coverage?

    PubMed

    O'Keefe, Daniel; McCormack, Angus; Cogger, Shelley; Aitken, Campbell; Burns, Lucinda; Bruno, Raimondo; Stafford, Jenny; Butler, Kerryn; Breen, Courtney; Dietze, Paul

    2017-08-01

    Recent work by McCormack et al. (2016) showed that the inclusion of syringe stockpiling improves the measurement of individual-level syringe coverage. We explored whether including the use of a new parameter, multiple sterile syringes per injecting episode, further improves coverage measures. Data comes from 838 people who inject drugs, interviewed as part of the 2015 Illicit Drug Reporting System. Along with syringe coverage questions, the survey recorded the number of sterile syringes used on average per injecting episode. We constructed three measures of coverage: one adapted from Bluthenthal et al. (2007), the McCormack et al. measure, and a new coverage measure that included use of multiple syringes. Predictors of multiple syringe use and insufficient coverage (<100% of injecting episodes using a sterile syringe) using the new measure, were tested in logistic regression and the ability of the measures to discriminate key risk behaviours was compared using ROC curve analysis. 134 (16%) participants reported needing multiple syringes per injecting episode. Women showed significantly increased odds of multiple syringe use, as did those reporting injection related injuries/diseases and injecting of opioid substitution drugs or pharmaceutical opioids. Levels of insufficient coverage across the three measures were substantial (20%-28%). ROC curve analysis suggested that our new measure was no better at discriminating injecting risk behaviours than the existing measures. Based on our findings, there appears to be little need for adding a multiple syringe use parameter to existing coverage formulae. Hence, we recommend that multiple syringe use is not included in the measurement of individual-level syringe coverage. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. The Language Exchange Programme: Plugging the Gap in Formal Learning

    ERIC Educational Resources Information Center

    Beaven, Tita; Gutiérrez, Mara Fuertes; Motzo, Anna

    2017-01-01

    In the context of distance language learning, speaking is frequently perceived as the most challenging skill; this paper reports on a 12 week summer language exchange programme providing students with new ways of practising their oral abilities. Students who completed an undergraduate beginners' language module took part in regular online,…

  10. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    PubMed

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P < 0.05). The endodontic pressure syringe showed the best results (98.5% optimal fillings) and jiffy tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  11. Nonprescription Syringe Sales: A Missed Opportunity for HIV Prevention in California

    PubMed Central

    Pollini, Robin A.; Rudolph, Abby E.; Case, Patricia

    2014-01-01

    Background California Senate Bill 41 (SB41), effective January 2012, is an HIV prevention measure designed to expand syringe access among injection drug users (IDUs) by allowing pharmacists to sell up to 30 syringes without a prescription. Objective We assessed SB41 implementation in two inland California counties where prevalence of injection drug use is among the highest in the nation. Design Syringe purchase trial. Setting Fresno and Kern counties, California. Participants All retail pharmacies (N=248). Main outcome measure Successful or unsuccessful syringe purchase attempt. Results Only 52 (21.0%) syringe purchase attempts were successful. The proportion of successful attempts did not vary by county or by data collector ethnicity. The most common reasons for unsuccessful syringe purchase attempts were prescription requirements (45.7%), the requested syringe size was not available (10.7%), and the pharmacy did not sell syringes (9.7%). In addition, some syringe purchase attempts (4.1%) were unsuccessful because the data collector was asked to purchase more syringes than allowed by law. Although 80% and 78% of Fresno and Kern residents, respectively, live within a 5-minute drive of a retail pharmacy, less than half live within a 5-minute drive of a pharmacy that sold syringes. Conclusion SB41 has not resulted in broad pharmacy-based syringe access in California's inland counties, where a disproportionate number of HIV/AIDS cases are associated with injection drug use. Additional steps by legislative bodies, regulatory agencies, and professional organizations are needed to actively engage pharmacies in expanding nonprescription syringe sales to reduce HIV transmission among IDUs. PMID:25575149

  12. Access to syringes for HIV prevention for injection drug users in St. Petersburg, Russia: syringe purchase test study

    PubMed Central

    2013-01-01

    Background The HIV epidemic in Russia is concentrated among injection drug users (IDUs). This is especially true for St. Petersburg where high HIV incidence persists among the city’s estimated 80,000 IDUs. Although sterile syringes are legally available, access for IDUs may be hampered. To explore the feasibility of using pharmacies to expand syringe access and provide other prevention services to IDUs, we investigated the current access to sterile syringes at the pharmacies and the correlation between pharmacy density and HIV prevalence in St. Petersburg. Methods 965 pharmacies citywide were mapped, classified by ownership type, and the association between pharmacy density and HIV prevalence at the district level was tested. We selected two districts among the 18 districts – one central and one peripheral – that represented two major types of city districts and contacted all operating pharmacies by phone to inquire if they stocked syringes and obtained details about their stock. Qualitative interviews with 26 IDUs provided data regarding syringe access in pharmacies and were used to formulate hypotheses for the pharmacy syringe purchase test wherein research staff attempted to purchase syringes in all pharmacies in the two districts. Results No correlation was found between the density of pharmacies and HIV prevalence at the district level. Of 108 operating pharmacies, 38 (35%) did not sell syringes of the types used by IDUs; of these, half stocked but refused to sell syringes to research staff, and the other half did not stock syringes at all. Overall 70 (65%) of the pharmacies did sell syringes; of these, 49 pharmacies sold single syringes without any restrictions and 21 offered packages of ten. Conclusions Trainings for pharmacists need to be conducted to reduce negative attitudes towards IDUs and increase pharmacists’ willingness to sell syringes. At a structural level, access to safe injection supplies for IDUs could be increased by including syringes in the federal list of mandatory medical products sold by pharmacies. PMID:23452390

  13. Effects of naloxone distribution alone or in combination with addiction treatment with or without pre-exposure prophylaxis for HIV prevention in people who inject drugs: a cost-effectiveness modelling study.

    PubMed

    Uyei, Jennifer; Fiellin, David A; Buchelli, Marianne; Rodriguez-Santana, Ramon; Braithwaite, R Scott

    2017-03-01

    In the USA, an epidemic of opioid overdose deaths is occurring, many of which are from heroin. Combining naloxone distribution with linkage to addiction treatment or pre-exposure prophylaxis (PrEP) for HIV prevention through syringe service programmes has the potential to save lives and be cost-effective. We estimated the outcomes and cost-effectiveness of five alternative strategies: no additional intervention, naloxone distribution, naloxone distribution plus linkage to addiction treatment, naloxone distribution plus PrEP, and naloxone distribution plus linkage to addiction treatment and PrEP. We developed a decision analytical Markov model to simulate opioid overdose, HIV incidence, overdose-related deaths, and HIV-related deaths in people who inject drugs in Connecticut, USA. Model input parameters were derived from published sources. We compared each strategy with no intervention, as well as simultaneously considering all strategies. Sensitivity analysis was done for all variables. Linkage to addiction treatment was referral to an opioid treatment programme for methadone. Endpoints were survival, life expectancy, quality-adjusted life-years (QALYs), number and percentage of overdose deaths averted, number of HIV-related deaths averted, total costs (in 2015 US$) associated with each strategy, and incremental cost per QALY gained. In the base-case analysis, compared with no additional intervention, the naloxone distribution strategy yielded an incremental cost-effectiveness ratio (ICER) of $323 per QALY, and naloxone distribution plus linkage to addiction treatment was cost saving compared with no additional intervention (greater effectiveness and less expensive). The most efficient strategies (ie, those conferring the greatest health benefit for a particular budget) were naloxone distribution combined with linkage to addiction treatment (cost saving), and naloxone distribution combined with PrEP and linkage to addiction treatment (ICER $95 337 per QALY) at a willingness-to-pay threshold of $100 000. In probabilistic sensitivity analysis, the combination of naloxone distribution, PrEP, and linkage to addiction treatment was the optimal strategy in 37% of iterations and the combination of naloxone distribution and linkage to addiction treatment was the optimal strategy in 34% of iterations. Naloxone distribution through syringe service programmes is cost-effective compared with syringe distribution alone, but when combined with linkage to addiction treatment is cost saving compared with no additional services. A strategy that combines naloxone distribution, PrEP, and linkage to addiction treatment results in greater health benefits in people who inject drugs and is also cost-effective. State of Connecticut Department of Public Health and the National Institute of Mental Health. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND license. Published by Elsevier Ltd.. All rights reserved.

  14. Barriers to Access to Sterile Syringes as Perceived by Pharmacists and Injecting Drug Users: Implications for Harm Reduction in Lebanon.

    PubMed

    Ghaddar, Ali; Nassar, Karine; Elsoury, Ghadier

    2017-09-19

    Access to sterile syringes to injecting drug users (IDU) reduces sharing behavior and prevents the transmission of HIV. To describe the barriers to access to sterile syringes for IDUs in Lebanon from the perspectives of pharmacists and IDUs. in this qualitative study conducted in Lebanon, data were collected from 72 syringe purchase tests at pharmacies, 64 interviewees with pharmacists and 2 focus groups with injecting drug users. Two independent researchers analyzed the verbatim transcripts. Results revealed that pharmacists often deny access to sterile syringes to IDUs who are frequently stigmatized and intimidated at pharmacies. While no large gender differences in pharmacists' attitudes and practices were observed, inequalities in syringe access were noticed with men IDUs more often denied purchase. Pharmacists had several barriers to sell syringes to IDUs including fear of disease spread, increased drug use, inappropriately discarded syringes, staff and customer safety, and business concerns. IDUs had several challenges to purchase syringes including stigmatization, intimidation, physical harassment, concern to reveal identity, fear of arrest and syringe price abuse. Identifying the barriers to and facilitators of access to sterile syringes to IDUs is important to guide the development of efficient policies. Findings implicate the importance of empowering IDUs to purchase syringes at pharmacies through reducing the negative attitude towards IDUs and strengthening pharmacists' role in the promotion of health of IDUs. Findings also suggest that the habit of syringe sharing would decrease if the legal and cultural barriers to access are reduced.

  15. A rapid and simple pretreatment method for benzoylurea insecticides in honey samples using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids.

    PubMed

    Wang, Huazi; Hu, Lu; Li, Wanzhen; Lu, Runhua; Zhang, Sanbing; Zhou, Wenfeng; Gao, Haixiang

    2016-11-04

    A pretreatment method using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids before high performance liquid chromatography analysis was developed for the determination of benzoylurea insecticides (BUs) in honey samples. The hydrophobic ionic liquid [N 4444 ][PF 6 ], formed in situ by the hydrophilic ionic liquid [N 4444 ]Cl and the ion exchange reagent KPF 6 , was used to extract the target analytes. The entire extraction procedure was performed in a syringe. The extractant was solidified at room temperature and collected using a nylon membrane filter. This technique did not require a dispersive solvent, vortex mixer, ultrasound bath, or centrifugation. The parameters affecting the extraction efficiency were investigated through an experimental design. Under the optimal conditions, the limits of detection for the four BUs varied from 0.21 to 0.42μgL -1 in solution (2.1-4.2μgkg -1 in honey). Good linearities were obtained in the range of 2-300μgL -1 , with coefficients of determination greater than 0.999. The recoveries of the four BUs ranged from 80.94% to 84.59%. The intra-day (n=3) and inter-day (n=3) relative standard deviations were less than 5.08%. Finally, the proposed method was applied to the determination of BUs in commercial honey samples with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Nonprescription syringe sales: a missed opportunity for HIV prevention in California.

    PubMed

    Pollini, Robin A; Rudolph, Abby E; Case, Patricia

    2015-01-01

    To assess implementation of California Senate Bill SB41 in two inland California counties where prevalence of injection drug use is among the highest in the nation. Syringe purchase trial. Fresno and Kern counties, California. All 248 community pharmacies in the counties. Successful or unsuccessful syringe purchase attempt. Only 52 (21.0%) syringe purchase attempts were successful. The proportion of successful attempts did not vary by county or by data collector ethnicity. The most common reasons for unsuccessful syringe purchase attempts were prescription requirements (45.7%), the requested syringe size was not available (10.7%), and the pharmacy did not sell syringes (9.7%). In addition, some syringe purchase attempts (4.1%) were unsuccessful because the data collector was asked to purchase more syringes than allowed by law. Although 80% and 78% of Fresno and Kern residents, respectively, live within a 5-minute drive of a community pharmacy, less than one-half live within a 5-minute drive of a community pharmacy that sold syringes. SB41 has not resulted in broad pharmacy-based syringe access in California's inland counties, where a disproportionate number of cases of human immunodeficiency virus (HIV) infections are associated with injection drug use. Additional steps by legislative bodies, regulatory agencies, and professional organizations are needed to actively engage pharmacies in expanding nonprescription syringe sales to reduce HIV transmission among injection drug users.

  17. Efficacy of air/water syringe tip sterilization.

    PubMed

    Inger, M; Bennani, V; Farella, M; Bennani, F; Cannon, R D

    2014-03-01

    Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones. © 2014 Australian Dental Association.

  18. Taking Action for Looked after Children in School: A Knowledge Exchange Programme

    ERIC Educational Resources Information Center

    Carroll, Catherine; Cameron, Claire

    2017-01-01

    Promoting the Achievement of Looked After Children (PALAC) is a knowledge exchange programme that aims to support the development of practice in schools and to expand the evidence base to ultimately improve outcomes for children in care. Feedback on the first year of PALAC exceeded expectations, with practitioners using their projects to evaluate…

  19. The Intercultural and Non-Formal Learning Processes of Children in Primary School Exchange Programmes in France and Germany

    ERIC Educational Resources Information Center

    Melin, Valérie; Wagner, Bernd

    2015-01-01

    This paper is based on educational anthropology, and presents the initial findings of a three-year international comparative study of primary school children's learning-processes during travel and cross-cultural encounters. A French-German research team investigated and here reports on primary school exchange programmes. Open coding of the…

  20. Syringe possession arrests are associated with receptive syringe sharing in two Mexico-US border cities

    PubMed Central

    Pollini, Robin A.; Brouwer, Kimberly C.; Lozada, Remedios M.; Ramos, Rebeca; Cruz, Michelle F.; Magis-Rodriguez, Carlos; Case, Patricia; Burris, Scott; Pu, Minya; Frost, Simon D. W.; Palinkas, Lawrence A.; Miller, Cari; Strathdee, Steffanie A.

    2008-01-01

    Aims To identify factors associated with receptive syringe sharing among injection drug users (IDUs) and elucidate the association between syringe possession arrests and syringe sharing. Design Cross-sectional study. Setting Mexican border cities of Tijuana, Baja California and Ciudad Juarez, Chihuahua. Participants IDUs in Tijuana (n = 222) and Ciudad Juarez (n = 206) were recruited using respondent-driven sampling (RDS). IDUs were ≥18 years and had injected illicit drugs in the past month. Measurements An interviewer-administered survey was used to collect quantitative data on socio-demographic, behavioral and contextual characteristics, including self-reported syringe sharing and arrests for syringe possession. Associations with receptive syringe sharing were investigated using logistic regression with RDS adjustment. Findings Overall, 48% of participants reported ever being arrested for carrying an unused/sterile syringe, even though syringe purchase and possession is legal in Mexico. Arrest for possessing unused/sterile syringes was associated independently with receptive syringe sharing [adjusted odds ratio (AOR) = 2.05; 95% confidence interval (CI): 1.26, 3.35], as was injecting in a shooting gallery (AOR = 3.60; 95% CI: 2.21, 5.87), injecting in the street (AOR = 2.05; 95% CI: 1.18, 3.54) and injecting methamphetamine (AOR = 2.77; 95% CI: 1.41, 5.47) or cocaine (AOR = 1.96; 95% CI: 1.15, 3.36). More than half of participants (57%) had been arrested for possessing a used syringe; in a second model, arrest for used syringe possession was also associated independently with receptive sharing (AOR = 2.87; 95% CI: 1.76, 4.69). Conclusions We documented high levels of syringe-related arrests in two Mexican–US border cities and an independent association between these arrests and risky injection practices. Public health collaborations with law enforcement to modify the risk environment in which drug use occurs are essential to facilitate safer injection practices. PMID:18028520

  1. Syringe size: does it matter in physician-performed procedures?

    PubMed

    Michael, Adrian A; Moorjani, Gautam R; Peisajovich, Andres; Park, Kye S; Sibbitt, Wilmer L; Bankhurst, Arthur D

    2009-03-01

    We hypothesized that the size of syringe influenced needle control in physician-performed procedures. Operators were tested for their ability to control a 1-, 3-, 5-, 10-, and 20-mL syringe and equivalent sizes of the new safety device, the reciprocating procedure device (RPD), using the quantitative needle-based displacement method. Three hundred twenty clinical syringe procedures were then randomized to either a 3- or 10-mL conventional syringe or to a 3- or 10-mL RPD. Patient pain was measured with the Visual Analog Pain Scale (VAPS). Increasing syringe size was associated with the undesirable characteristic of unintended forward penetration (loss of control of the needle in the forward direction) (r(2) = 0.97, slope = 2.14, 95% CI: 1.54-2.76, P < 0.002), and unintended retraction (loss of control of the needle in the reverse direction) (r(2) = 0.97, slope 2.15, 95% CI: 1.54-2.76, P < 0.002). In addition, 2-handed operation of a syringe resulted in greater control than 1-handed operation of a syringe (P < 0.001). When 1-handed operation was required, the RPD control syringe reduced unintended penetration by 52.3% (P >or= 0.001), unintended retraction by 56.8% (P >or= 0.001), and patient pain by 54.7% (P >or= 0.001) at each device size. For greater safety and control when operating the conventional syringe, smaller syringe sizes and 2 hands instead of 1 hand should be used whenever possible. If 1-handed operation of a syringe is necessary, a safety technology like the RPD control syringe should be used.

  2. Activity spaces among injection drug users in San Francisco.

    PubMed

    Martinez, Alexis N; Lorvick, Jennifer; Kral, Alex H

    2014-05-01

    Representations of activity spaces, defined as the local areas within which people move or travel in the course of their daily activities, are unexplored among injection drug users (IDUs). The purpose of this paper is to use an activity space framework to study place and drug user health. Data for this analysis is from an epidemiological study of street-recruited IDUs in San Francisco (N=1084). Study participants reported geographic intersections of where they most often slept at night, hung out during the day, and used drugs during a 6 month time period. We used GIS software to construct and map activity space routes of street-based network paths between these intersections. We further identified if syringe exchange program (SEP) locations intersected with, participant activity space routes. We used logistic regression to estimate associations between activity space variables and HIV serostatus, syringe sharing, and non-fatal overdose, after adjusting for individual and Census tract covariates. Mean activity space distance for all participants was 1.5miles. 9.6% of participants had a SEP located along their activity space. An increase in activity space distance was associated with a decrease in odds of being HIV positive. An increase in residential transience, or the number of different locations slept in by participants in a 6 month time period, was associated with higher odds of syringe sharing. Activity space distance was not independently associated with overdose or syringe sharing. Research that locates individuals in places of perceived importance is needed to inform placement and accessibility of HIV and overdose prevention programs. More attention needs to be given to the logistics of collecting sensitive geospatial data from vulnerable populations as well as how to maximize the use of GIS software for visualizing and understanding how IDUs interact with their environment. Copyright © 2013. Published by Elsevier B.V.

  3. Quality evaluation of radiographic contrast media in large-volume prefilled syringes and vials.

    PubMed

    Sendo, T; Hirakawa, M; Yaginuma, M; Aoyama, T; Oishi, R

    1998-06-01

    The authors compared the particle contaminations of radiographic contrast media packaged in large-volume prefilled syringes and vials. Particle counting was performed for four contrast media packaged in large-volume prefilled syringes (iohexol, ioversol, ioversol for angiography, and ioxaglate) and three contrast media packaged in vials (iohexol, ioversol, and ioxaglate). X-ray emission spectrometry was performed to characterize the individual particles. The amount of silicone oil in the syringe was quantified with infrared spectrophotometry. The particle contamination in syringes containing ioversol was higher than that in syringes containing iohexol or ioxaglate. Particle contamination in the vials was relatively low, except with ioxaglate. X-ray emission spectrometry of the components of the syringe and vial showed that the source of particles was internal material released from the rubber stopper or inner surface. The particle counts for contrast media packaged in syringes and vials varied considerably among the different contrast media and were related to the amount of silicone oil on the inner surface and rubber piston of the syringe.

  4. Structure of the syringeal muscles in jungle crow (Corvus macrorhynchos).

    PubMed

    Tsukahara, Naoki; Yang, Qian; Sugita, Shoei

    2008-09-01

    Birds' vocalizations are produced by the syrinx, which is located between the trachea and the two primary bronchi. Oscine birds have multiple pairs of syringeal muscles in the syrinx. To determine the detailed structure of the syringeal muscle in jungle crows, an oscine bird, a histological study and gross examination of the syrinx were performed. In the histological study, sections of the syrinxes from four jungle crows were stained with Azan and observed. Each syringeal muscle was classified by the limit of the fascia from neighbor fascicules. From the gross examination a 3-D image of the structure of the syringeal muscles was generated. The combined histological and anatomical results show that there are seven pairs of syringeal muscles in jungle crows. Muscle fusions were observed in some of the syringeal muscles. It is likely that each syringeal muscle has a specific role. Jungle crows may be able to generate various calls because they have several pairs of syringeal muscles.

  5. Extractables and leachables considerations for prefilled syringes.

    PubMed

    Jenke, Dennis R

    2014-10-01

    Use of pre-filled syringes as both a packaging and delivery system for pharmaceutical drug products is accelerating. Pre-filled syringes must meet the quality and suitability for use requirements for both systems, including compatibility with the drug product. Relevant incompatibilities between pre-filled syringes and drug products include the safety of syringe-based leachables that accumulate in drug products and the ability of leachables to interact with the drug product's ingredients as such interactions can affect safety, efficacy, stability and physical viability. Relevant suitability considerations for pre-filled syringes are discussed herein and specific examples of suitability for use issues for pre-filled syringes are cited, focusing on extractables associated with pre-filled syringes and leachables derived from such syringes. Aspects considered include the toxicological impact of leachables, their ability to alter the efficacy of drug products and to produce other undesirable outcomes such as aggregation and immunogenic responses. Materials used in pre-filled syringes and the conditions of use minimize the traditional safety risk associated with leachables. However, drug products that use pre-filled syringes are prone to non-traditional interactions such as disruption of protein conformation, leading to potential efficacy, safety and quality issues. In order to qualify pre-filled syringes for use, the traditional approach of measuring extractables and leachables and inferring their effect must be augmented by rigorous compatibility testing. Research into the fundamental relationship between leachables and drug substances will be necessary so the more time- and cost-efficient 'measure and infer' approach can be widely implemented.

  6. Volumetric Lattice Boltzmann Simulation for Fluid dynamics and Turbulence in Practical Syringes

    NASA Astrophysics Data System (ADS)

    Lima, Everton; Deep, Debanjan; Yu, Huidan (Whitney)

    2012-11-01

    We conduct numerical experiments to study fluid dynamics and turbulence in syringes using volumetric lattice Boltzmann method (VLBM) that is developed for dealing with arbitrary moving boundaries. Several common used medical syringes are used to predict the efficiency and safety of syringes experiencing low flow infusion rates. It is found that smaller size syringes reach a steady flow rate much sooner than larger ones, which are in quantitative agreement with experimental results. The relation between the syringe size and its steady flow rate is revealed. At low flow rates, corner vortices are observed. We explore conditions that lead to turbulent flow aiming to aid safer syringe application in nursing practices.

  7. Patients' Reactions to Local Anaesthetic Application Devices in Paediatric Dentistry.

    PubMed

    Bajrić, Elmedin; Kobasglija, Sedin; Jurić, Hrvoje

    2015-09-01

    Local anaesthesia is the most common medium for pain control in most dental treatments. Physical appearance of syringe itself can be considered as a provoking factor for the emergence of dental fear and anxiety (DFA). In this research the patient reactions to local anaesthesia application devices, as one of the main causes for DFA emergence, were inquired. The sample comprised of 120 patients, divided in three age groups, formed of 40 patients aged 8, 12 and 15 years. DFA prevalence was quantified by Children Fear Survey Schedule-Dental Subscale (CFSS-DS). Three different syringes were offered to the patients. Reasons for choosing one of the syringes were detected. Patients assigned statistically highest rank to plastic syringe. Boys chose metal and intraligamental syringe statistically more often than girls. Patients with higher CFSS-DS scores chose metal syringe as last option. None of the reasons for selection was dominant, except pain that could be caused by usage of any of the three syringes. A large number of patients did not mention any of the reasons for choosing particular syringes. Plastic syringe represented the most acceptable device for local anaesthetic application to our patients. Patients often linked pain with dental syringes.

  8. Impact of increased syringe access: preliminary findings on injection drug user syringe source, disposal, and pharmacy sales in Harlem, New York.

    PubMed

    Fuller, Crystal M; Ahern, Jennifer; Vadnai, Liza; Coffin, Phillip O; Galea, Sandro; Factor, Stephanie H; Vlahov, David

    2002-01-01

    To evaluate the New York State Expanded Syringe Access Demonstration Program (ESAP) through injection drug user (IDU) surveys, discarded needles and syringes studies, and pharmacy sales and experiences surveys. Pre-post comparison. In Harlem, New York City, risk surveys among street-recruited IDUs, needle/syringe street counts on 27 systematically sampled city blocks, and Harlem pharmacist reports of sales and experiences. Number and types of IDU syringe sources, block mean counts of discarded needles and syringes, level of pharmacy nonprescription syringe sales (NPSS), and pharmacists' experiences. Comparing 209 pre-ESAP with 396 post-ESAP IDUs, pharmacies as a primary syringe source increased: 3.4% to 5.3% (P < .001, and ever pharmacy use increased: 4.9% to 12.5% (P < .001), respectively. Compared with pre-ESAP IDUs, post-ESAP IDUs tended to be younger and more often black. Harlem pharmacy participation in ESAP increased considerably from March 1, 2001, to March 1, 2002, 49% to 79%, respectively. Among three Harlem pharmacies, there was a modest increase in NPSS; pharmacists reported no problems, and no discarded needles and syringes were observed in pharmacy areas. In the three pharmacies, the proportion of syringe sales that were NPSS was 46% (110 to 240 NPSS/month), 3% (25 to 90 NPSS/month), and 0%. The mean ratios of needles/syringes to background trash have not increased in Harlem since ESAP began. To date, no evidence of harmful effects discarded needles/syringes, pharmacy altercations) resulting from ESAP were observed. While NPSS have increased in Harlem, pharmacy use among IDUs remains low. In Harlem, efforts are underway to increase ESAP awareness and reduce socioenvironmental barriers to ESAP.

  9. Characterization of the initial level and migration of silicone oil lubricant in empty prefilled syringes for biologics using infrared spectroscopy.

    PubMed

    Bee, Jared S; Frey, Vadim V; Javed, Urooj; Chung, Jonathan; Corcoran, Marta L; Roussel, Paul S; Krause, Stephan O; Cash, Patricia W; Bishop, Steven M; Dimitrova, Mariana N

    2014-01-01

    Glass prefillable syringes are lubricated with silicone oil to ensure functionality and a consistent injection for the end user. If excessive silicone is applied, droplets could potentially result in aggregation of sensitive biopharmaceuticals or clouding of the solution. Therefore, monitoring and optimization of the applied silicone layer is critical for prefilled syringe development. The hydrophobic properties of silicone oil, the potential for assay interference, and the very small quantities applied to prefilled syringes present a challenge for the development of a suitable assay. In this work we present a rapid and simple Fourier transform infrared (FTIR) spectroscopy method for quantitation of total silicone levels applied to prefilled syringes. Level-dependent silicone oil migration occurred over time for empty prefilled syringes stored tip-up. However, migration from all prefilled syringes with between 0.25 and 0.8 mg of initial silicone oil resulted in a stable limiting minimum level of between 0.15 and 0.26 mg of silicone in the syringe reached after 1 to 4 years of empty tip-up storage. The results of the FTIR assay correlated well with non-destructive reflectometry characterization of the syringes. This assay can provide valuable data for selection of a robust initial silicone oil target and quality control of prefilled syringes intended for biopharmaceuticals. Glass prefillable syringes are lubricated with silicone oil to ensure functionality and a consistent injection for the end user. If excessive silicone is applied, droplets could potentially result in aggregation of sensitive biopharmaceuticals or clouding of the solution. Therefore, monitoring and optimization of the applied silicone layer is critical for prefilled syringe development. The hydrophobic properties of silicone oil, the potential for assay interference, and the very small quantities applied to prefilled syringes present a challenge for the development of a suitable assay. In this work we present a rapid and simple Fourier transform infrared (FTIR) spectroscopy method for quantitation of total silicone levels applied to prefilled syringes. Level-dependent silicone oil migration occurred over time for empty prefilled syringes stored tip-up. However, migration from all prefilled syringes with between 0.25 and 0.8 mg of initial silicone oil resulted in a stable limiting minimum level of between 0.15 and 0.26 mg of silicone in the syringe reached after 1 to 4 years of empty tip-up storage. The results of the FTIR assay correlated well with non-destructive reflectometry characterization of the syringes. This assay can provide valuable data for selection of a robust initial silicone oil target and quality control of prefilled syringes intended for biopharmaceuticals. © PDA, Inc. 2014.

  10. A Good Learning Opportunity, but Is It for Me? A Study of Swedish Students' Attitudes towards Exchange Studies in Higher Education

    ERIC Educational Resources Information Center

    Ahn, Song-ee

    2014-01-01

    This article describes students' involvement and interest in exchange programmes in Swedish higher education. Law and Engineering bachelor's programmes were chosen to exemplify an over-represented and under-represented group respectively in terms of international mobility in this context. The study combines interview and survey data. The author…

  11. "I'm* Two Rabbits" / "J'ai un Rouge Pullover*". How Corrective Feedback Is Handled in Collaborative Exchange Programmes between Early Language Learners

    ERIC Educational Resources Information Center

    Choffat-Durr, Anne; Macaire, Dominique

    2012-01-01

    This article presents how, in the social dynamics of two classrooms involved in an exchange programme, young learners provide their peers with asynchronous feedback taking place in the digital medium. Within two Call Triangles that interact thanks to Computer Mediated Communication tools, teachers sharing the same methodological precept on…

  12. SCORE Study Report 7: incidence of intravitreal silicone oil droplets associated with staked-on vs luer cone syringe design.

    PubMed

    Scott, Ingrid U; Oden, Neal L; VanVeldhuisen, Paul C; Ip, Michael S; Blodi, Barbara A; Antoszyk, Andrew N

    2009-11-01

    To evaluate the incidence of intravitreal silicone oil (SO) droplets associated with intravitreal injections using a staked-on vs luer cone syringe design in the SCORE (Standard Care vs COrticosteroid in REtinal Vein Occlusion) Study. Prospective, randomized, phase III clinical trial. The incidence of intravitreal SO was compared among participants exposed to the staked-on syringe design, the luer cone syringe design, or both of the syringe designs in the SCORE Study, which evaluated intravitreal triamcinolone acetonide injection(s) for vision loss secondary to macular edema associated with central or branch retinal vein occlusion. Injections were given at baseline and 4-month intervals, based on treatment assignment and study-defined retreatment criteria. Because intravitreal SO was observed following injections in some participants, investigators were instructed, on September 22, 2006, to look for intravitreal SO at all study visits. On November 1, 2007, the luer cone syringe design replaced the staked-on syringe design. A total of 464 participants received a total of 1,205 injections between November 4, 2004 and February 28, 2009. Intravitreal SO was noted in 141 of 319 participants (44%) exposed only to staked-on syringes, 11 of 87 (13%) exposed to both syringe designs, and 0 of 58 exposed only to luer cone syringes (P < .0001). Among participants with first injections after September 22, 2006, intravitreal SO was noted in 65 of 114 (57%) injected only with staked-on syringes compared with 0 of 58 injected only with luer cone syringes. Differential follow-up is unlikely to explain these results. In the SCORE Study, luer cone syringe design is associated with a lower frequency of intravitreal SO droplet occurrence compared with the staked-on syringe design, likely attributable to increased residual space in the needle hub with the luer cone design.

  13. Compatibility of azathioprine sodium with intravenous fluids.

    PubMed

    Johnson, C A; Porter, W A

    1981-06-01

    The effects of storage containers, diluent, temperature, and illumination on the stability and compatibility of azathioprine sodium were studied. Reconstituted solutions were stored in the manufacturer's vial and a plastic syringe. Diluted solutions were stored in mini-bags mixed with standard intravenous solutions (5% dextrose injection, 0.9% sodium chloride injection, and 0.45% sodium chloride injection). Samples were stored at 4 degrees C in the dark and at 23 degrees C under constant illumination. Samples containing an internal standard, 6-methylmercaptopurine, were assayed by ion exchange chromatography at 0, 8, and 16 days. Accelerated decomposition studies at 70 degrees C also were performed to determine the chromatographic method's capability for separating azathioprine from its breakdown products. No solutions or admixtures differed significantly (p greater than 0.13) from initial concentrations after 16 days at 23 degrees C under constant illumination. Mixture with 5% dextrose injection caused precipitation by day 16. Azathioprine sodium reconstituted and stored in the manufacturer's vial or a plastic syringe at 4 degrees C formed a precipitate by day 4. Sterility is the limiting factor determining suitability for use of azathioprine solutions kept less than four days.

  14. Injection and Sexual HIV/HCV Risk Behaviors Associated with Nonmedical Use of Prescription Opioids among Young Adults in New York City

    PubMed Central

    Mateu-Gelabert, Pedro; Guarino, Honoria; Jessell, Lauren; Teper, Anastasia

    2014-01-01

    Prevalence of nonmedical prescription opioid (PO) use has increased markedly in the U.S. This qualitative study explores the drug-use and sexual experiences of nonmedical PO users as they relate to risk for HIV and HCV transmission. Forty-six New York City young adult nonmedical PO users (ages 18–32) completed in-depth, semi-structured interviews. Despite initial perceptions of POs as less addictive and safer than illegal drugs, PO misuse often led to long-term opioid dependence and transition to heroin use and drug injection. Injectors in the sample reported sporadic syringe-sharing, frequent sharing of non-syringe injection paraphernalia and selective sharing with fellow injectors who are presumed “clean” (uninfected). Participants reported little knowledge of HCV injection-related risks and safer injection practices. They also reported engaging in unprotected sex with casual partners, exchange sex and group sex, and that PO misuse increases the risk of sexual violence. Prevention efforts addressing HIV/HCV risk should be targeted to young nonmedical PO users. PMID:25124258

  15. [Embolic complications by ink clots removed from syringes during cerebral angiography].

    PubMed

    Kohyama, Shinya; Ishihara, Shoichiro; Yamane, Fumitaka; Ishihara, Hideaki; Kanazawa, Ryuzaburo; Suzuki, Masanori; Neki, Hiroaki; Ohkawara, Mai

    2009-01-01

    We noted, during cerebral angiography, that the contrast medium was contaminated with numerous small black ink clots from gradation marks on syringes. In this report, we show that ink can be removed from syringes in solid form, and that they may result in embolic complications during cerebral angiography. To demonstrate that the ink from gradation marks on syringes can come off in a solid form and attach itself to the gloves during cerebral angiography, syringes were gripped many times (just as in an angiographic procedure) after immersion in contrast medium or 0.9% saline for 10 minutes. To see if difference of contrast medium and syringes could affect the removing of ink, five types of nonangiographic syringes and one type of angiographic syringe were rubbed with gauze after certain time periods after immersing them in four kinds of contrast medium or 0.9% saline. Ink attached itself to the gloves in a solid form by repeated gripping due to adherence of contrast medium. Ink was removed from all nonangiographic syringes by rubbing after immersion in any type of contrast medium for two hours. Gradation marks on angiographic syringes were stable with all types of contrast medium. Thus, ink for gradation marks on nonangiographic syringes, which is easily removed in a solid form due to contrast medium, can be the source of embolic complication during cerebral angiography.

  16. Demographic, Risk, and Spatial Factors Associated With Over-the-Counter Syringe Purchase Among Injection Drug Users

    PubMed Central

    Stopka, Thomas J.; Lutnick, Alexandra; Wenger, Lynn D.; DeRiemer, Kathryn; Geraghty, Estella M.; Kral, Alex H.

    2012-01-01

    Since 2005, California law allowed over-the-counter (OTC) syringe sales pending local authorization. Although pharmacy sales of OTC syringes are associated with reduced injection-mediated risks and decreases in human immunodeficiency virus infection rates, little is known about the factors associated with syringe purchase among injection drug users (IDUs). Using a cross-sectional design, the authors applied targeted sampling to collect quantitative survey data from IDUs (n = 563) recruited in San Francisco, California, during 2008. They also compiled a comprehensive list of retail pharmacies, their location, and whether they sell OTC syringes. They used a novel combination of geographic information system and statistical analyses to determine the demographic, behavioral, and spatial factors associated with OTC syringe purchase by IDUs. In multivariate analyses, age, race, injection frequency, the type of drug injected, and the source of syringe supply were independently associated with OTC syringe purchases. Notably, the prevalence of OTC syringe purchase was 53% lower among African-American IDUs (adjusted prevalence ratio = 0.47, 95% confidence interval: 0.33, 0.67) and higher among injectors of methamphetamine (adjusted prevalence ratio = 1.35, 95% confidence interval: 1.07, 1.70). Two neighborhoods with high densities of IDUs had limited access to OTC syringes. Increased access to OTC syringes would potentially prevent blood-borne infectious diseases among IDUs. PMID:22562660

  17. A Method To Determine the Kinetics of Solute Mixing in Liquid/Liquid Formulation Dual-Chamber Syringes.

    PubMed

    Werk, Tobias; Mahler, Hanns-Christian; Ludwig, Imke Sonja; Luemkemann, Joerg; Huwyler, Joerg; Hafner, Mathias

    Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products, which cannot be co-formulated due to technical or regulatory issues. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercial dual-chamber syringes (with a bypass designed as a longitudinal ridge) when the two liquids significantly differ in their physical properties (viscosity, density). However, an optimized dual-chamber syringe design with multiple bypass channels resulted in improved mixing of liquids. Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercially available dual-chamber syringes when the two liquids significantly differ in viscosity and density. However, an optimized dual-chamber syringe design resulted in improved mixing of liquids. © PDA, Inc. 2017.

  18. [2000-year history of the ear syringe and its relationship to the enema. Images from the history of otorhinolaryngology, represented by instruments from the collection of the Ingolstadt Medical History Museum].

    PubMed

    Feldmann, H

    1999-08-01

    SYRINGES WITH A PISTON AND THEIR USE AS "CLYSTER ORICULARIUS" IN THE ANCIENT ROME: Syringes with a piston were already known in ancient times and have been mentioned as a device for spraying rose water (Philon of Byzantium, about 230 BC), and for fighting fires (Heron of Alexandria about 110 AD). Celsus mentions it several times in his grand opus "De Medicina" (1st century AD) in the treatment of purulent discharge from the ear and for removing foreign bodies from the external ear canal. He always calls it "clyster oricularius", i.e. ear syringe, even when he describes its use in applications other than otological, such as in urology. Later the ear syringe fell from favor for a very long time and was reinvented only at the beginning of the 19th century. IRRIGATION OF THE BOWELS, FROM THE BAG SYRINGE TO THE PISTON SYRINGE: Irrigations of the bowels, clysters, were performed from ancient times to the 18th century with a baglike syringe using the bladder of animals as a pouch. Syringes with a piston were used by barbers and surgeons only for cleansing wounds or irrigating natural cavities of the body. Irrigation of the external ear canal had completely fallen from favor. In France in the 18th century large syringes with a piston made of tin oder brass came into use for enemas and replaced the old baglike devices. THE REINVENTION OF THE EAR SYRINGE AFTER THE PROTOTYPE OF THE ENEMA SYRINGE: Itard, an otologist in France in 1821, was the first to describe irrigating the ear with a syringe to remove hard wax. He recommended using an enema syringe ("seringue à lavement") for the procedure. Soon after his publication special ear syringes of appropriate size were developed and described by Beck in Freiburg, Germany, in 1827; by Fabrizi in Modena, Italy, 1839; and Schmalz in Dresden, Germany, 1846, who also introduced the kidney-shaped bowel for catching the water. Apart from that, small baglike syringes made of rubber were devised especially for use by the patient himself (Kramer, Berlin, 1860). This historical development is described in detail and illustrated by numerous figures.

  19. Botulinum Toxin Therapy: Is Syringe Type Related to Cost-Effectiveness?

    PubMed

    Foglietti, Mark Anthony; Wright, Lauren; Foglietti-Fostyk, Alanna

    2018-03-01

    Clostridium botulinum toxin is effective through cleaving presynaptic proteins at the neuromuscular junction, which prevents the release of acetylcholine and inhibits muscle contraction. Several serotypes of botulinum toxin (BT) exist; however, only 2 types have been approved by the US Food and Drug Administration for commercial and medical use, A and B. Both types of BT must be administered intramuscularly with a syringe, but the type of syringe is the injector's preference. Which syringe type is most efficient in minimizing product waste and most cost-effective for the patient and provider? We performed a single-center, open-label, analytical study using BT therapy and 2 types of syringes for analytics of cost-effectiveness. OnabotulinumtoxinA was the neuromodulator used in this report. Vials (100 U) of BT A were each reconstituted with 2.5 mL of 0.9% sodium chloride, for a final concentration of 4 U/0.1 mL. High-dead-space syringes are compared with low-dead-space syringes: 1-mL tuberculin (TB) luer slip syringe with detachable 25-gauge needle and 1-mL ultrafine insulin syringe with an attached 31-gauge needle, respectively. After each syringe was evacuated, the TB syringe was noted to contain 0.05 mL of the remaining product in the hub. Providers are discarding approximately 2 U of BT per TB syringe product injection. If the physician uses 30 syringes per day, 3 days a week, for 1 year, it equals to a lost revenue of approximately $155,500 per year. To individualize the cost-effective analysis, average quantity of syringes used per patient and overall patient volume must be considered, with corresponding adjustment of cost and units discarded. The American Society of Plastic Surgeons reported that the use of neuromodulators has increased by approximately 797% from 2000 to 2016. During that period, the price of neuromodulators has also increased by approximately 85%. Considering these statistics, the type of syringe used for BT neuromodular injection is a thought-provoking concept but surrounded by a paucity of data. Overall, our data suggest that the use of ultrafine insulin syringes for injection of BT reduces product waste and is cost-effective for the patient and the provider.

  20. Ongoing incident hepatitis C virus infection among people with a history of injecting drug use in an Australian prison setting, 2005-2014: The HITS-p study.

    PubMed

    Cunningham, E B; Hajarizadeh, B; Bretana, N A; Amin, J; Betz-Stablein, B; Dore, G J; Luciani, F; Teutsch, S; Dolan, K; Lloyd, A R; Grebely, J

    2017-09-01

    Hepatitis C virus (HCV) transmission is high in prisons. This study investigated trends in HCV incidence and associated factors among a cohort of prisoners with a history of injecting drug use in New South Wales, Australia. Data were available from the Hepatitis C Incidence and Transmission Study-prisons (HITS-p) from 2005 to 2014. Temporal trends in HCV incidence were evaluated. Factors associated with time to HCV seroconversion among people with ongoing injecting was assessed using Cox proportional hazards. Among 320 antibody-negative participants with a history of injecting drug use (mean age 26; 72% male), 62% (n=197) reported injecting drug use during follow-up. Overall, 93 infections were observed. HCV incidence was 11.4/100 person-years in the overall population and 6.3/100 person-years among the continually imprisoned population. A stable trend in HCV incidence was observed. Among the overall population with ongoing injecting during follow-up, ≥weekly injecting drug use frequency was independently associated with time to HCV seroconversion. Among continuously imprisoned injectors with ongoing injecting during follow-up, needle/syringe sharing was independently associated with time to HCV seroconversion. This study demonstrates that prison is a high-risk environment for acquisition of HCV infection. Needle and syringe sharing was associated with HCV infection among continually imprisoned participants, irrespective of frequency of injecting or the type of drug injected. These findings highlight the need for the evaluation of improved HCV prevention strategies in prison, including needle/syringe programmes and HCV treatment. © 2017 John Wiley & Sons Ltd.

  1. Displacement of Canada's largest public illicit drug market in response to a police crackdown

    PubMed Central

    Wood, Evan; Spittal, Patricia M.; Small, Will; Kerr, Thomas; Li, Kathy; Hogg, Robert S.; Tyndall, Mark W.; Montaner, Julio S.G.; Schechter, Martin T.

    2004-01-01

    Background Law enforcement is often used in an effort to reduce the social, community and health-related harms of illicit drug use by injection drug users (IDUs). There are, however, few data on the benefits of such enforcement or on the potential harms. A large-scale police “crackdown” to control illicit drug use in Vancouver's Downtown Eastside provided us with an opportunity to evaluate the effect. Methods As part of our ongoing prospective cohort study of IDUs in Vancouver, we examined data collected from 244 IDUs in the 3 months before the police crackdown and from 142 IDUs in the 3 months after the start of the crackdown, on Apr. 7, 2003. All study subjects were active drug users. We also examined external data on needle exchanges and syringe disposal. Results The 2 groups of IDUs were statistically similar: they were mainly young (mean age 39 years) and male (63%), and they had injected illicit drugs for 13 years on average. Ethnic background and the proportion homeless were also similar. There were no statistically significant reported differences (all p > 0.1) in the street price of heroin, cocaine or “crack” in the 2 periods. In the 3-month periods before and after the crackdown, respectively, the rates of daily heroin injection were 27.9% and 26.8%, daily cocaine injection 28.7% and 27.5%, and daily crack use 59.4% and 60.6% (all p > 0.1). The proportions of study subjects receiving methadone treatment, 41.0% and 44.4% (p = 0.516), did not differ. However, the proportions reporting a change in where drugs were used, 22.5% and 33.8% (p < 0.05), and the proportions reporting a change in the neighbourhood of use because of police presence, 18.1% and 26.8% (p < 0.05), increased significantly. Needle-exchange data confirmed that the community levels of drug use were unchanged. Disposal statistics demonstrated that the monthly average number of used syringes found on the streets outside the traditional area of drug use increased from 784 in the 3 months before Apr. 1 to 1253 in the subsequent 3 months (p = 0.002) and the monthly average number of used syringes found in public boxes for the safe disposal of syringes decreased from 865 to 502 (p = 0.018). Interpretation The effort to control illicit drug use did not alter the price of drugs or the frequency of use, nor did it encourage enrolment in methadone treatment programs. Several measures indicated displacement of injection drug use from the area of the crackdown into adjacent areas of the city, which has implications for both recruitment of new initiates into injection drug use and HIV prevention efforts. PMID:15136548

  2. Displacement of Canada's largest public illicit drug market in response to a police crackdown.

    PubMed

    Wood, Evan; Spittal, Patricia M; Small, Will; Kerr, Thomas; Li, Kathy; Hogg, Robert S; Tyndall, Mark W; Montaner, Julio S G; Schechter, Martin T

    2004-05-11

    Law enforcement is often used in an effort to reduce the social, community and health-related harms of illicit drug use by injection drug users (IDUs). There are, however, few data on the benefits of such enforcement or on the potential harms. A large-scale police "crackdown" to control illicit drug use in Vancouver's Downtown Eastside provided us with an opportunity to evaluate the effect. As part of our ongoing prospective cohort study of IDUs in Vancouver, we examined data collected from 244 IDUs in the 3 months before the police crackdown and from 142 IDUs in the 3 months after the start of the crackdown, on Apr. 7, 2003. All study subjects were active drug users. We also examined external data on needle exchanges and syringe disposal. The 2 groups of IDUs were statistically similar: they were mainly young (mean age 39 years) and male (63%), and they had injected illicit drugs for 13 years on average. Ethnic background and the proportion homeless were also similar. There were no statistically significant reported differences (all p > 0.1) in the street price of heroin, cocaine or "crack" in the 2 periods. In the 3-month periods before and after the crackdown, respectively, the rates of daily heroin injection were 27.9% and 26.8%, daily cocaine injection 28.7% and 27.5%, and daily crack use 59.4% and 60.6% (all p > 0.1). The proportions of study subjects receiving methadone treatment, 41.0% and 44.4% (p = 0.516), did not differ. However, the proportions reporting a change in where drugs were used, 22.5% and 33.8% (p < 0.05), and the proportions reporting a change in the neighbourhood of use because of police presence, 18.1% and 26.8% (p < 0.05), increased significantly. Needle-exchange data confirmed that the community levels of drug use were unchanged. Disposal statistics demonstrated that the monthly average number of used syringes found on the streets outside the traditional area of drug use increased from 784 in the 3 months before Apr. 1 to 1253 in the subsequent 3 months (p = 0.002) and the monthly average number of used syringes found in public boxes for the safe disposal of syringes decreased from 865 to 502 (p = 0.018). The effort to control illicit drug use did not alter the price of drugs or the frequency of use, nor did it encourage enrollment in methadone treatment programs. Several measures indicated displacement of injection drug use from the area of the crackdown into adjacent areas of the city, which has implications for both recruitment of new initiates into injection drug use and HIV prevention efforts.

  3. Increased Access to Unrestricted Pharmacy Sales of Syringes in Seattle–King County, Washington: Structural and Individual-Level Changes, 1996 Versus 2003

    PubMed Central

    Deibert, Ryan J.; Goldbaum, Gary; Parker, Theodore R.; Hagan, Holly; Marks, Robert; Hanrahan, Michael; Thiede, Hanne

    2006-01-01

    We examined pharmacists’ attitudes and practices related to syringe sales to injection drug users before and after legal reform and local programming to enhance sterile syringe access. We replicated a 1996 study by conducting pharmacist phone surveys and syringe test-buys in randomly selected pharmacies. Test-buy success increased from 48% in 1996 to 65% in 2003 (P=.04). Pharmacists agreeing that syringes should be available to injection drug users through pharmacy purchase increased from 49% to 71% (P<.01). Pharmacy policies and pharmacist attitudes were strongly associated with syringe access. Structural changes, including policy reform and pharmacy outreach, appear to increase syringe access. Interventions should address pharmacy policies and pharmacist attitudes and policies. PMID:16809607

  4. Pre-departure preparation and co-curricular activities for Students' intercultural exchange: A mixed-methods study.

    PubMed

    Chan, E Angela; Liu, Justina Yat Wa; Fung, Keith Hin Kee; Tsang, Pak Lik; Yuen, John

    2018-04-01

    Nurses are required to be culturally competent to provide quality care to an increasingly diverse and ageing population. International exchange programmes were developed to support the traditional nursing curriculum. These programmes have often overlooked the importance of pre-departure preparation and co-curricular activities to the development of intercultural competency. To explore the influence of pre-departure and co-curricular activities on the intercultural learning experiences of both exchange and host students in a short-term international summer programme. A mixed-methods study. Students were recruited from international and mainland exchange partners, with host students as ambassadors. The international summer programme involved a week of online pre-departure activities and two weeks of face-to-face meetings. A convenience sample of 62 students from diverse cultural backgrounds was recruited on a voluntary basis. The participants were aged between 19 and 27. Data were collected from students' pre- and post-visit questionnaires, discussions within the workshops, their online discussion threads, and focus group discussions. The quantitative findings suggested that students' cultural intelligence improved significantly after the exchange programme. Qualitatively, three themes emerged as: 1) Students' motivation to engage in intercultural learning; 2) Barriers to intercultural communication; 3) Enablers of intercultural communication. Pre-departure preparation enabled students to discuss their common goals and expectations, while exploring differences, asked for practical living information, and used the basic intercultural concepts in their discussion on the care of elderly. This virtual encounter has lay the foundation for students' subsequent discussions about the why and how the differences that inform their own practices and about global ageing and poverty issues during their co-curricular activities. While the pre-departure preparation could serve as a stimulus, the value of this programme for intercultural learning also rests with the importance of debriefing to further students' reflective and experiential learning. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Reuse prevention syringes for reconstitution of lyophilized vaccines: Operational study and UNICEF plans for expanding introduction.

    PubMed

    Fleming, Jessica A; Hoekstra, Edward John; Moniaga, Vanda; Widjaya, Anton; Soepardi, Jane; Supartha, Nyoman; Salovaara, Annika; Khamassi, Selma; Nelson, Carib

    2009-01-01

    Since the 1990s, the United Nation's Children's Fund has encouraged injection safety for immunizations through bundling vaccines with appropriate amounts of supporting equipment and by supplying autodisable (AD) syringes for injections. However, poor vaccine reconstitution practices continue to be reported worldwide. By 2009, UNICEF will begin to phase out the distribution of standard disposable syringes for vaccine reconstitution and replace them with reuse prevention (RUP) syringes, with a full transition expected by the end of 2010. A field evaluation in Indonesia was conducted to identify introduction requirements, issues with healthcare worker training and acceptance, and RUP syringe performance and safety. Managers and health workers felt that RUP syringes improved injection safety and fit easily into country logistical systems. Healthcare workers felt they were intuitive to use, but recommended special training. The integration of RUP reconstitution syringes by UNICEF could increase injection safety by preventing the reuse of syringes and reducing vaccine contamination.

  6. Co-infection by human immuno deficiency virus, hepatitis B and hepatitis C virus in injecting drug users.

    PubMed

    Devi, Kh Sulochana; Brajachand, Ng; Singh, H Lokhendro; Singh, Y Manihar

    2005-03-01

    Injecting drug users (IDUs) are at risk of parenterally transmitted diseases such as hepatitis B virus (HBV) hepatitis C virus (HCV) and human immunodeficiency virus (HIV) infections. The present study was undertaken to find out the prevalence of HIV infection, HBV infection and HCV infection among IDUs of a deaddiction centre. Serum samples from 250, injecting drug users (IDUs) from a de-addiction centre were screened for HBsAg using immunochromatography, anti HCV antibody by 3rd generation ELISA test and anti HIV antibody by ELISA test and immunochromatographic rapid test during the period August to October 2002. One hundred and forty-nine (59.6%) IDUs were positive for HIV antibody, 226 (90.4%) were positive for anti HCV antibody and 27 (10.8%) were positive for HBsAg. There was co-infection of HIV, HBV and HCV in 15 (6%) of the IDUs. The Co-infection of HBV and HCV were found in 12 cases (4.8%) and Co-infection of HIV and HCV was found in 131 cases (52.4%). The IDUs were in sexually active age group with a risk of infection to their sexual partner. There is high prevalence of HCV and HIV infection and co-infection of both viruses among IDUs. Comprehensive public health interventions targeting this population and their sexual partners must be encouraged. Increase coverage of needle, syringe exchange programme (NSEP) to young and new IDUs is required before they are exposed to blood borne viruses.

  7. Barriers and Potential Improvements for Needle and Syringe Exchange Programs (NSPs) in China: A Qualitative Study from Perspectives of Both Health and Public Security Sectors

    PubMed Central

    Chow, Eric P. F.; Jing, Jun; Zheng, Jun; Zhao, Junshi; Zhang, Lei

    2015-01-01

    This study explores the acceptability, the barriers to the implementation of needle and syringe exchange programs (NSPs) and the potential improvement strategies in China from the perspectives of governmental health and public security officials. Purposive sampling was used for recruitment of participants who had been involved in NSPs implementation. Semi-Structured individual interviews were conducted in Mandarin to address three aspects of NSPs: (1) participants’ attitudes towards NSPs, (2) participants’ opinions on the effectiveness and barriers of NSPs, and (3) suggestions for improving the program. Content analysis was used to analyse the translated interview data. A total of 68 participants from 12 Hunan counties were interviewed (34 from each of the Bureau of Health and the Narcotic Division). Both groups recognised the importance and effectiveness of NSPs in HIV prevention, but public security officials regarded NSPs as a temporary intervention in place of punitive measures. Most health officials (32/34) regarded the main barriers to its implementation as administrative and structural, whereas participants from Narcotics Division (n=24) questioned the legitimacy of NSPs and concerned about the poor management of drug users’ risk behaviours. Close cooperation between the health and public security sectors, engagement of the drug user community and an enabling policy environment were reportedly to be critical for potential improvements of NSPs in China. Misconceptions about NSPs encourage drug users’ addictive behaviour, and an unclear leadership and insufficient support de-motivate the participants from the Bureau of Health and the Narcotics Division to actively support the program implementation. PMID:26114556

  8. Cost and acceptability of three syringe-pump infusion systems.

    PubMed

    Johnson, M S; Pesko, L J; Wood, C F; Reinders, T P

    1990-08-01

    The fiscal impact and acceptability of implementing a syringe-pump infusion system at a 900-bed university teaching hospital where the minibag system has been in use is reported. Researchers selected three models of syringe pumps for evaluation: the Bard Harvard Mini-Infuser 150XL, the Becton Dickinson 360 Infuser, and the Strato Stratofuse System. Each pump was evaluated for three weeks on a medical-surgical unit and a hematology-oncology unit. Drugs to be infused were chosen after a literature review to determine which drugs had been successfully infused via syringe pump; 22 formulary medications were selected. Syringes were prepared as singly packaged doses or as doses prepared in bulk and packaged frozen. Control of the syringe pumps and microbore tubing was assigned to the inpatient pharmacy staff. Nurses and pharmacy personnel were apprised of the study and taught how to use the syringe pumps. Time-and-motion studies were performed in the sterile products preparation area, and a cost analysis was done. Nurses preferred syringe pumps over the minibag system because the pumps reduced the nursing time needed to infuse a drug, administered less fluid, provided consistent infusion rates, had alarms, and were relatively easy to use. The time required to prepare syringes did not differ substantially among syringe-pump models. It was estimated that using any of the evaluated pumps in place of the minibag system would save $126,500 during the three-year period 1988-91, primarily because of differences in the cost of disposable items. The syringe-pump infusion system is an acceptable and cost-effective alternative to the minibag system.

  9. Wrap spring clutch syringe ram and frit mixer

    DOEpatents

    Simpson, Frank B.

    2006-07-25

    A wrap spring clutch syringe ram pushes at least one syringe with virtually instantaneous starting and stopping, and with constant motion at a defined velocity during the intervening push. The wrap spring clutch syringe ram includes an electric motor, a computer, a flywheel, a wrap spring clutch, a precision lead screw, a slide platform, and syringe reservoirs, a mixing chamber, and a reaction incubation tube. The electric motor drives a flywheel and the wrap spring clutch couples the precision lead screw to the flywheel when a computer enables a solenoid of the wrap spring clutch. The precision lead screw drives a precision slide which causes syringes to supply a portion of solution into the mixing chamber and the incubation tube. The wrap spring clutch syringe ram is designed to enable the quantitative study of solution phase chemical and biochemical reactions, particularly those reactions that occur on the subsecond time scale.

  10. Oral syringe use survey.

    PubMed

    Baldwin, J N; Wedemeyer, H F

    1980-09-01

    Use of oral syringes at children's and ASHP-accredited residency hospitals in the United States was surveyed. Questionnaires were mailed to 131 hospitals; 117 (89.3%) were returned. Of the responding hospitals, 54.5% of children's hospitals and 67.1% of residency hospitals used oral syringes. There was no definite preference for a particular brand or type (glass vs. plastic) of syringe. Patients who often required liquid dosage forms, including pediatric and geriatric patients and patients with nasogastric tubes, were most frequently included in oral syringe distribution systems. Twenty-six of the 73 hospitals utilizing oral syringes used them for most unit dose liquids in all drug distribution systems. The remainder reported use for specific medications or circumstances. Expiration dating policies varied from 24 hours to one year to the manufacturer's expiration dating. The survey indicates widespread use of oral syringes and identifies a need for evaluation of medication stability in these devices.

  11. The cleaning of instruments and syringes

    PubMed Central

    Darmady, E. M.; Hughes, K. E. A.; Drewett, S. E.; Prince, D.; Tuke, Winifred; Verdon, Patricia

    1965-01-01

    The dangers to the handler of syringes used for routine injections were found to be negligible, but known infected syringes and those contaminated with antibiotics should be autoclaved before handling as a high proportion of these carry pathogenic organisms. Mechanical methods of cleaning syringes and instruments are assessed. The use of an artificial soil for testing purposes is described. Using this soil, ultrasonics by themselves are inadequate for cleaning syringes and instruments. Agitation with ultrasonics is essential for syringes, but is insufficient for instruments. Detergents are therefore an essential adjunct to the cleaning process. For syringes Pyroneg proved to be the most satisfactory, particularly if they had been previously siliconized. The best detergent for instruments contaminated with these types of soil was Penesolve 814 at a temperature of 95°C. but the instruments must be adequately rinsed after this treatment. A number of other detergents and cleaning agents are discussed. PMID:14247708

  12. Bilateral innervation of syringeal muscles by the hypoglossal nucleus in the jungle crow (Corvus macrorhynchos).

    PubMed

    Tsukahara, Naoki; Kamata, Naoki; Nagasawa, Miyuki; Sugita, Shoei

    2009-08-01

    Bird vocalizations are produced by contractions of syringeal muscles, which are controlled by the hypoglossal nucleus. In oscines, syringeal muscles are controlled by the hypoglossal nucleus ipsilaterally, whereas syringeal innervation is bilateral in non-oscines. We have determined the course of hypoglossal nerves in the jungle crow Corvus macrorhynchos. Our results indicate a cross-over of the hypoglossal nerve from the left side to the right side on the trachea 7 mm rostral to the Musculus sternotrachealis. We also investigated the innervation of the syringeal muscles of jungle crows from the hypoglossal nucleus using the horseradish peroxidase (HRP) method. After HRP was injected into the syringeal muscles on each side, HRP-labeled cells were found bilaterally in the hypoglossal nerve. These results suggest that the syringeal muscles of jungle crows are innervated bilaterally from the hypoglossal nucleus, although these birds are categorized as oscines.

  13. Bilateral innervation of syringeal muscles by the hypoglossal nucleus in the jungle crow (Corvus macrorhynchos)

    PubMed Central

    Tsukahara, Naoki; Kamata, Naoki; Nagasawa, Miyuki; Sugita, Shoei

    2009-01-01

    Bird vocalizations are produced by contractions of syringeal muscles, which are controlled by the hypoglossal nucleus. In oscines, syringeal muscles are controlled by the hypoglossal nucleus ipsilaterally, whereas syringeal innervation is bilateral in non-oscines. We have determined the course of hypoglossal nerves in the jungle crow Corvus macrorhynchos. Our results indicate a cross-over of the hypoglossal nerve from the left side to the right side on the trachea 7 mm rostral to theMusculus sternotrachealis. We also investigated the innervation of the syringeal muscles of jungle crows from the hypoglossal nucleus using the horseradish peroxidase (HRP) method. After HRP was injected into the syringeal muscles on each side, HRP-labeled cells were found bilaterally in the hypoglossal nerve. These results suggest that the syringeal muscles of jungle crows are innervated bilaterally from the hypoglossal nucleus, although these birds are categorized as oscines. PMID:19490396

  14. Syringe Sharing Among a Prospective Cohort of Street-Involved Youth: Implications for Needle Distribution Programs.

    PubMed

    Bozinoff, Nikki; Wood, Evan; Dong, Huiru; Richardson, Lindsey; Kerr, Thomas; DeBeck, Kora

    2017-09-01

    The sharing of previously used syringes is associated with the transmission of Hepatitis C and HIV. This longitudinal study examines syringe borrowing and syringe lending within a prospective cohort of street-involved youth in Vancouver, Canada. From September 2005 to May 2014, data were collected from the At-Risk Youth Study, a cohort of street-involved youth age 14-26 at enrollment, and analyzed using generalized estimating equations. Among 505 participants, 142 (28.1%) reported syringe borrowing and 132 (26.1%) reported syringe lending during the study period. In separate multivariable analyses, having difficulty finding clean needles and homelessness were significantly associated with syringe borrowing (Adjusted Odds Ratio (AOR) = 2.28, 95% CI 1.66-3.12 and AOR = 1.52, CI 1.05-2.21, respectively) and syringe lending (AOR = 1.89, 95% CI 1.32-2.71 and AOR = 1.65, 95% CI 1.11-2.44, respectively) (all p values < 0.05). Findings highlight gaps in syringe access for vulnerable young injectors and suggest that service delivery for youth may be suboptimal. Further examination of how needle distribution efforts might be improved to better meet the needs of young people is warranted.

  15. Evaluation of child preference for dentist attire and usage of camouflage syringe in reduction of anxiety.

    PubMed

    Babaji, Prashant; Chauhan, Pavni P; Rathod, Vikram; Mhatre, Swapnil; Paul, Uttam; Guram, Guneet

    2017-01-01

    The aim of this study is to evaluate the child preference for dentist attire and camouflage versus conventional syringe in reduction of anxiety. A total of 600 children aged 6-14 years were made to look at a set of six photos of an individual dressed with different colored apron of pink, green, blue, white colors, formal dress, and cartoon character along with conventional syringe and camouflage syringe with a toy-like appearance to permit injection of local anesthesia. Children's anxiety level during injections and with colored coat was assessed and recorded using the Modified Child Dental Anxiety Scale faces version. SPSS statistical software version 21 and using Chi-square test. Among age group of 6-8 years, 65.33% selected colorful apron, while other age groups 9-10, 11-12 years, and 13-14 years selected 47.34%, 57.34%, and 50.67% white coat, respectively ( P < 0.05). For syringe, 78% of younger age group (6-10 years) preferred camouflage syringe, whereas 71% of older age group (11-14 years) preferred conventional syringe. Anxiety level of all children for syringe was more compared to that of white coat. Younger children prefer colorful attire of dentist and camouflage syringe over conventional compared to older one.

  16. Effects of naloxone distribution to likely bystanders: Results of an agent-based model.

    PubMed

    Keane, Christopher; Egan, James E; Hawk, Mary

    2018-05-01

    Opioid overdose deaths in the US rose dramatically in the past 16 years, creating an urgent national health crisis with no signs of immediate relief. In 2017, the President of the US officially declared the opioid epidemic to be a national emergency and called for additional resources to respond to the crisis. Distributing naloxone to community laypersons and people at high risk for opioid overdose can prevent overdose death, but optimal distribution methods have not yet been pinpointed. We conducted a sequential exploratory mixed methods design using qualitative data to inform an agent-based model to improve understanding of effective community-based naloxone distribution to laypersons to reverse opioid overdose. The individuals in the model were endowed with cognitive and behavioral variables and accessed naloxone via community sites such as pharmacies, hospitals, and urgent-care centers. We compared overdose deaths over a simulated 6-month period while varying the number of distribution sites (0, 1, and 10) and number of kits given to individuals per visit (1 versus 10). Specifically, we ran thirty simulations for each of thirteen distribution models and report average overdose deaths for each. The baseline comparator was no naloxone distribution. Our simulations explored the effects of distribution through syringe exchange sites with and without secondary distribution, which refers to distribution of naloxone kits by laypersons within their social networks and enables ten additional laypersons to administer naloxone to reverse opioid overdose. Our baseline model with no naloxone distribution predicted there would be 167.9 deaths in a six month period. A single distribution site, even with 10 kits picked up per visit, decreased overdose deaths by only 8.3% relative to baseline. However, adding secondary distribution through social networks to a single site resulted in 42.5% fewer overdose deaths relative to baseline. That is slightly higher than the 39.9% decrease associated with a tenfold increase in the number of sites, all distributing ten kits but with no secondary distribution. This suggests that, as long as multiple kits are picked up per visit, adding secondary distribution is at least as effective as increasing sites from one to ten. Combining the addition of secondary distribution with an increase in sites from one to ten resulted in a 61.1% drop in deaths relative to the baseline. Adding distribution through a syringe exchange site resulted in a drop of approximately 65% of deaths relative to baseline. In fact, when enabling distribution through a clean-syringe site, the secondary distribution through networks contributed no additional drops in deaths. Community-based naloxone distribution to reverse opioid overdose may significantly reduce deaths. Optimal distribution methods may include secondary distribution so that the person who picks up naloxone kits can enable others in the community to administer naloxone, as well as targeting naloxone distribution to sites where individuals at high-risk for opioid overdose death are likely to visit, such as syringe-exchange programs. This study design, which paired exploratory qualitative data with agent-based modeling, can be used in other settings seeking to implement and improve naloxone distribution programs. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  17. Potency and stability of frozen urokinase solutions in syringes.

    PubMed

    Dedrick, Stephen C; Ramirez-Rico, José

    2004-08-01

    The stability and potency of frozen urokinase solutions in syringes were studied. To determine the stability and potency of compounded urokinase dilutions after multiple freeze-thaw cycles, a total of 160 syringes containing five urokinase concentrations (2,500, 5,000, 7,500, 12,500, and 25,000 IU/mL) were prepared. For each of the five concentrations tested, two syringes per concentration were reserved for baseline testing. The remaining 150 syringes were frozen at -30 degrees C. After 7 days, half of the syringes (group 1) were thawed at room temperature, tested, and left at room temperature for 12 hours before refreezing. The other half of the syringes (group 2) were kept frozen for 30 days. Thirty days after initial compounding, all syringes were thawed, and the samples' urokinase potency, pH, and physical appearance were evaluated. Syringes were visually inspected for color, clarity, and precipitation. Descriptive statistics were computed for each concentration group and testing day. The compounded dilutions were stable under each experimental condition, with no physical deterioration or loss of in vitro potency after two freeze-thaw cycles. The reduced waste associated with the ability to refreeze unused urokinase could substantially lower the cost of procedures such as thrombolysis after intraventricular hemorrhage and catheter clearance by as much as 95%. Dilutions of urokinase 2,500-25,000 IU/mL were stable in single-use syringes after being frozen for 7 days, thawed, and refrozen for another 23 days.

  18. Nonprescription syringe sales: Resistant pharmacists' attitudes and practices.

    PubMed

    Chiarello, Elizabeth

    2016-09-01

    To examine barriers to nonprescription syringe sales (NPSS) in pharmacies by examining resistant pharmacists' willingness to provide syringes to people who inject drugs (PWID) and their current practices for provision or refusal. Qualitative, semi-structured, in-depth interviews with community pharmacists in California, Kansas, Mississippi, and New Jersey. Participants include seventeen community pharmacists who expressed ethical concerns about providing syringes drawn from a larger sample of 71 community pharmacists participating in a study of ethical decision-making. Analysis captures pharmacists' descriptions of their experiences providing syringes to suspected PWID. Pharmacists who identified syringes as a key ethical issue exhibited significant ambivalence about providing syringes to PWID. Most of these pharmacists were aware of harm reduction logics, but endorsed them to varying degrees. Moral concerns about supplying PWID with syringes were mediated by law and organizational policy. Many pharmacists who considered syringes an ethical challenge allayed their concerns by creating informal policy and engaging in deterrence practices designed to dissuade PWID from coming to the pharmacy. As heroin abuse rates continue to rise, pharmacists are undoubtedly integral allies in the fight to prevent the spread of communicable diseases like HIV/AIDS and Hepatitis C. Education should be aimed at identifying barriers to NPSS resulting from resistant pharmacists' attitudes and practices. Increased education paired with favorable law and organizational policy and decentralization of syringe provision could increase access to clean needles and decrease public health risks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. [Trial manufacture of a plunger shield for a disposable plastic syringe].

    PubMed

    Murakami, Shigeki; Emoto, Takashi; Mori, Hiroshige; Fujita, Katsuhisa; Kubo, Naoki

    2008-08-20

    A syringe-type radiopharmaceutical being supplied by a manufacturer has a syringe shield and a plunger shield, whereas an in-hospital labeling radiopharmaceutical is administered by a disposable plastic syringe without the plunger shield. In cooperation with Nihon Medi-Physics Co. Ltd., we have produced a new experimental plunger shield for the disposable plastic syringe. In order to evaluate this shielding effect, we compared the leaked radiation doses of our plunger shield with those of the syringe-type radiopharmaceutical (Medi shield type). Our plunger shield has a lead plate of 21 mm in diameter and 3 mm thick. This shield is equipped with the plunger-end of a disposal plastic syringe. We sealed 99mTc solution into a plastic syringe (Terumo Co.) of 5 ml with our plunger shield and Medi shield type of 2 ml. We measured leaked radiation doses around syringes using fluorescent glass dosimeters (Dose Ace). The number of measure points was 18. The measured doses were converted to 70 microm dose equivalent at 740 MBq of radioactivity. The results of our plunger shield and the Medi shield type were as follows: 4-13 microSv/h and 3-14 microSv/h at shielding areas, 3-545 microSv/h and 6-97 microSv/h at non-shielding areas, 42-116 microSv/h and 88-165 microSv/h in the vicinity of the syringe shield, and 1071 microSv/h and 1243 microSv/h at the front of the needle. For dose rates of shielding areas around the syringe, the shielding effects were approximately the same as those of the Medi shield type. In conclusion, our plunger shield may be useful for reducing finger exposure during the injection of an in-hospital labeled radiopharmaceutical.

  20. A System for Anesthesia Drug Administration Using Barcode Technology: The Codonics Safe Label System and Smart Anesthesia Manager.

    PubMed

    Jelacic, Srdjan; Bowdle, Andrew; Nair, Bala G; Kusulos, Dolly; Bower, Lynnette; Togashi, Kei

    2015-08-01

    Many anesthetic drug errors result from vial or syringe swaps. Scanning the barcodes on vials before drug preparation, creating syringe labels that include barcodes, and scanning the syringe label barcodes before drug administration may help to prevent errors. In contrast, making syringe labels by hand that comply with the recommendations of regulatory agencies and standards-setting bodies is tedious and time consuming. A computerized system that uses vial barcodes and generates barcoded syringe labels could address both safety issues and labeling recommendations. We measured compliance of syringe labels in multiple operating rooms (ORs) with the recommendations of regulatory agencies and standards-setting bodies before and after the introduction of the Codonics Safe Label System (SLS). The Codonics SLS was then combined with Smart Anesthesia Manager software to create an anesthesia barcode drug administration system, which allowed us to measure the rate of scanning syringe label barcodes at the time of drug administration in 2 cardiothoracic ORs before and after introducing a coffee card incentive. Twelve attending cardiothoracic anesthesiologists and the OR satellite pharmacy participated. The use of the Codonics SLS drug labeling system resulted in >75% compliant syringe labels (95% confidence interval, 75%-98%). All syringe labels made using the Codonics SLS system were compliant. The average rate of scanning barcodes on syringe labels using Smart Anesthesia Manager was 25% (730 of 2976) over 13 weeks but increased to 58% (956 of 1645) over 8 weeks after introduction of a simple (coffee card) incentive (P < 0.001). An anesthesia barcode drug administration system resulted in a moderate rate of scanning syringe label barcodes at the time of drug administration. Further, adaptation of the system will be required to achieve a higher utilization rate.

  1. [Economic impact of strategies using ephedrine prefilled syringes].

    PubMed

    Crégut-Corbaton, J; Malbranche, C; Guignard, M-H; Fagnoni, P

    2013-11-01

    Ephedrine is an emergency drug available in ampules and syringes need to be prepared in advance according to one of two strategies in our establishment: strategy 1 (S1: 1 ampule per patient) and strategy 2 (S2: 1 ampule per operating room). There are also prefilled syringes. Because of their high cost and conflicting results in the literature, we assessed the economic interest of using prefilled syringes compared with strategies S1 and S2. This was a prospective observational study. The consumption of ephedrine was recorded over two periods of 14 days: P1 with syringes prepared in advance according to S1 or S2 and P2 with the on-demand use of prefilled syringes. The cost of a syringe of ephedrine prepared in advance (nurse time preparation included) was evaluated at €1.65 vs. €3.57 for a prefilled syringe. In operating rooms using S1, the use of prefilled syringes reduced overall the cost per patient about €1.22 and global annual costs by 72% (€2830), while the decrease was about €0.32 for the cost per patient and about 47% (€2760) for global annual costs for operating rooms using S2. The interest of our study is that we investigated different supply strategies for ephedrine within a large number of operating rooms. In our establishment, it was decided to use prefilled syringes in operating rooms that used S1. As well as the economic interest, prefilled syringes contributed to improved safety and saved nursing time. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  2. Adverse event associated with a change in nonprescription syringe sale policy.

    PubMed

    Zaller, Nickolas D; Yokell, Michael A; Jeronimo, Alexandra; Bratberg, Jeffrey P; Case, Patricia; Rich, Josiah D

    2010-01-01

    To report and describe the possible correlation of a change in syringe sale policy at a community pharmacy with an adverse clinical outcome. Providence, RI, in summer 2009. 27-year-old white woman with a long-standing history of chronic relapsing opiate addiction and human immunodeficiency virus (HIV)/hepatitis C virus (HCV) coinfection. The patient presented to the hospital emergency department with 5 days of severe diffuse pain, swelling in her hands and feet, and several days of rigors with fevers, sweats, and chills. She was diagnosed with sepsis resulting from a disseminated methicillin-resistant Staphylococcus aureus (MRSA) infection. The patient was treated with intravenous antibiotics, neurosurgical drainage of an epidural abscess, intensive care unit care for 1 week, and acute hospitalization for 8 weeks. Not applicable. A few weeks before the patient was hospitalized, pharmacists at her local neighborhood pharmacy decided to stop selling syringes in packages of 10. Instead, syringes were sold at a minimum quantity of 100. The patient did not know where to obtain sterile syringes and began reusing syringes. The patient introduced pathogenic bacteria from her skin into her bloodstream through unsafe injection practices. The change in syringe sale policy at her local pharmacy likely inadvertently contributed to this severe and life-threatening situation. Consideration of the implications of syringe sale policy must include an understanding of the barriers that influence individual pharmacist's decisions regarding particular store policies that affect over-the-counter syringe sales. Legalized sale of nonprescription syringes in community pharmacies alone is not enough to curb the epidemic of unsafe injection practices in the United States. All medical risks that are inherent in the use of unsafe syringes, including blood-borne viral pathogens (e.g., HIV, HCV) and bacterial infections (e.g., MRSA), should be considered.

  3. Study abroad as a process of learning intercultural competence in nursing.

    PubMed

    Koskinen, Liisa; Tossavainen, Kerttu

    2004-06-01

    The aim of this research was to describe an international student exchange programme as a context of learning intercultural competence in nursing. Twelve Finnish nursing students who had participated in an exchange programme in the United Kingdom participated. The data consisted of group interviews, learning documents, background questionnaires and research diary notes, and the method of inductive content analysis was used. Study abroad as a process of learning intercultural competence consisted of three ethno-categories: transition from one culture to another, adjustment to the difference and gaining intercultural sensitivity. The exchange programme as a context of learning intercultural competence was characterized by a problematic orientation phase, a study abroad phase that involved stressful but rewarding adjustment to the intercultural differences and an inadequate re-entry debriefing phase. In order for the international experience of nursing students to have an impact on their understanding of diversity, they need assistance in each phase of the programme. Particularly, the students need intercultural tutoring and mentoring to venture into encounters with local people, including direct client contacts, during their study abroad.

  4. Investigation of Two Prototypes of Novel Noncontact Technologies for Automated Real-Time Capture of Incremental Drug Administration Data From Syringes.

    PubMed

    Eagle, Benjamin; Williams, David J; Dingley, John

    2017-08-01

    An ideal electronic anesthesia recording system would be capable of not only recording physiological data but also injectable drug doses given, including those given incrementally from one syringe, without recourse to manual data entry. We compared 2 prototype devices which wirelessly recognized individual syringes and measured changes in their plunger positions via 2 different optical noncontact means, allowing calculation of incremental drug doses given. Both devices incorporated a radio-frequency identification reader, which wirelessly read a unique code from a radio-frequency identification tag within syringe drug labels. A custom-designed cradle oriented any inserted 1-mL to 20-mL syringe in a repeatable position. The "laser" device had a moving laser beam broken by the end of the syringe plunger. The infrared (IR) device measured time of travel of IR light from a sender to a syringe plunger and back to a receiver. Both devices could therefore determine the drug and volume administered since the previous occasion when any syringe had been used. For each syringe size of 1, 2, 5, 10, and 20 mL, 121 plunger-length measurements were made over their full range, with each machine against a reference method of water filling and weighing using a randomized de Bruijn sequence. For every syringe size, the laser device showed greater accuracy and precision, lower bias, and narrower limits of agreement (95% confidence intervals = bias ± 1.96 SD) than the IR device when compared to the reference method. For all syringe sizes, the range of bias was -0.05 to 0.32 mL for the laser and -2.42 to 1.38 mL for the IR. Lin concordance correlation coefficient values for the IR versus reference methods ranged from 0.6259 to 0.9255, with the lowest coefficients seen in syringes with the shortest distance of plunger travel (2 and 5 mL), while in laser versus reference comparisons, these coefficients were similar (0.9641-0.9981) over all syringe lengths. Both devices measured syringe volume changes, demonstrating potential for measuring incremental drug doses, recording these, and also the time of each measurement. The IR device had no moving parts, which would be advantageous in a clinical situation. However, the current embodiment was not deemed accurate enough for clinical use, potentially remediable through improvements in hardware and software design. The laser device showed high accuracy and precision over all syringe sizes and contained volumes, and was considered potentially accurate enough for clinical use with suitable development.

  5. Methods To Determine the Silicone Oil Layer Thickness in Sprayed-On Siliconized Syringes.

    PubMed

    Loosli, Viviane; Germershaus, Oliver; Steinberg, Henrik; Dreher, Sascha; Grauschopf, Ulla; Funke, Stefanie

    2018-01-01

    The silicone lubricant layer in prefilled syringes has been investigated with regards to siliconization process performance, prefilled syringe functionality, and drug product attributes, such as subvisible particle levels, in several studies in the past. However, adequate methods to characterize the silicone oil layer thickness and distribution are limited, and systematic evaluation is missing. In this study, white light interferometry was evaluated to close this gap in method understanding. White light interferometry demonstrated a good accuracy of 93-99% for MgF 2 coated, curved standards covering a thickness range of 115-473 nm. Thickness measurements for sprayed-on siliconized prefilled syringes with different representative silicone oil distribution patterns (homogeneous, pronounced siliconization at flange or needle side, respectively) showed high instrument (0.5%) and analyst precision (4.1%). Different white light interferometry instrument parameters (autofocus, protective shield, syringe barrel dimensions input, type of non-siliconized syringe used as base reference) had no significant impact on the measured average layer thickness. The obtained values from white light interferometry applying a fully developed method (12 radial lines, 50 mm measurement distance, 50 measurements points) were in agreement with orthogonal results from combined white and laser interferometry and 3D-laser scanning microscopy. The investigated syringe batches (lot A and B) exhibited comparable longitudinal silicone oil layer thicknesses ranging from 170-190 nm to 90-100 nm from flange to tip and homogeneously distributed silicone layers over the syringe barrel circumference (110- 135 nm). Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. A silicone oil layer thickness of 100-200 nm was thus sufficient for adequate functionality in this particular study. Filling the syringe with a surrogate solution including short-term exposure and emptying did not significantly influence the silicone oil layer at the investigated silicone level. It thus appears reasonable to use this approach to characterize silicone oil layers in filled syringes over time. The developed method characterizes non-destructively the layer thickness and distribution of silicone oil in empty syringes and provides fast access to reliable results. The gained information can be further used to support optimization of siliconization processes and increase the understanding of syringe functionality. LAY ABSTRACT: Silicone oil layers as lubricant are required to ensure functionality of prefilled syringes. Methods evaluating these layers are limited, and systematic evaluation is missing. The aim of this study was to develop and assess white light interferometry as an analytical method to characterize sprayed-on silicone oil layers in 1 mL prefilled syringes. White light interferometry showed a good accuracy (93-99%) as well as instrument and analyst precision (0.5% and 4.1%, respectively). Different applied instrument parameters had no significant impact on the measured layer thickness. The obtained values from white light interferometry applying a fully developed method concurred with orthogonal results from 3D-laser scanning microscopy and combined white light and laser interferometry. The average layer thicknesses in two investigated syringe lots gradually decreased from 170-190 nm at the flange to 100-90 nm at the needle side. The silicone layers were homogeneously distributed over the syringe barrel circumference (110-135 nm) for both lots. Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. Syringe filling with a surrogate solution, including short-term exposure and emptying, did not significantly affect the silicone oil layer. The developed, non-destructive method provided reliable results to characterize the silicone oil layer thickness and distribution in empty siliconized syringes. This information can be further used to support optimization of siliconization processes and increase understanding of syringe functionality. © PDA, Inc. 2018.

  6. 78 FR 20116 - Draft Guidance for Industry and Food and Drug Administration Staff; Glass Syringes for Delivering...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ...] Draft Guidance for Industry and Food and Drug Administration Staff; Glass Syringes for Delivering Drug... and FDA staff entitled ``Glass Syringes for Delivering Drug and Biological Products: Technical... supplemental data are necessary for FDA to ensure the safe and effective use of glass syringes that comply with...

  7. Micro-engineered remote palpation device for assessing tissue compliance.

    PubMed

    Hien, M; Yang, T H J; Leung, S K W; Reuben, R L; Habib, F K; McNeill, S A; Schneider, A; McBride, G; Stevens, R; Else, R W

    2008-01-01

    This paper concerns the operation of the actuator for a prototype micro-engineered mechanical palpation device for deployment via a cystoscope to measure the dynamic mechanical properties of the prostate gland in vivo. The subassembly consists of a 400x200 microm silicon (Si) piston manufactured using deep reactive ion etching (DRIE) housed within an anodically bonded glass-Si-glass sandwiched housing. The micro-channel on the Si layer was formed by powder blasting and contains the micro-piston with one end pointing to the side of the housing and the other facing a via hole leading to a capillary tube. The opening on the side of the housing was sealed by a 5 microm thick silicone membrane which acts to retain the micro-piston and act as a return spring. A 320 microm diameter capillary forms the connection between the micro-channel and a micro-syringe which is operated by a programmable syringe pump to produce a reciprocating action. A pressure sensor is connected along the capillary tube to measure the dynamic pressure within the system. The micro-piston has already been used, separately actuated to measure the dynamic mechanical properties of known viscoelastic materials and prostate tissue. The purpose of the present work is to assess the functionality of the actuator assembly.

  8. Automated dynamic liquid-liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection for the determination of phenoxy acid herbicides in environmental waters.

    PubMed

    Wu, Jingming; Ee, Kim Huey; Lee, Hian Kee

    2005-08-05

    Automated dynamic liquid-liquid-liquid microextraction (D-LLLME) controlled by a programmable syringe pump and combined with HPLC-UV was investigated for the extraction and determination of 5 phenoxy acid herbicides in aqueous samples. In the extraction procedure, the acceptor phase was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. The repetitive movement of acceptor phase into and out of the hollow fiber channel facilitated the transfer of analytes into donor phase, from the organic phase held in the pore of the fiber. Parameters such as the organic solvent, concentrations of the donor and acceptor phases, plunger movement pattern, speed of agitation and ionic strength of donor phase were evaluated. Good linearity of analytes was achieved in the range of 0.5-500 ng/ml with coefficients of determination, r2 > 0.9994. Good repeatabilities of extraction performance were obtained with relative standard deviations lower than 7.5%. The method provided up-to 490-fold enrichment within 13 min. In addition, the limits of detection (LODs) ranged from 0.1 to 0.4 ng/mL (S/N = 3). D-LLLME was successfully applied for the analysis of phenoxy acid herbicides from real environmental water samples.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less

  10. Stability of acetylcysteine solution repackaged in oral syringes and associated cost savings.

    PubMed

    Kiser, Tyree H; Oldland, Alan R; Fish, Douglas N

    2007-04-01

    The physical and chemical stability of repackaged acetylcysteine 600 mg/3 mL solution in oral syringes stored under refrigeration or at room temperature was studied for six months; a cost analysis was also conducted. Acetylcysteine 20% solution for inhalation was repackaged undiluted as 600 mg/3 mL in capped oral syringes and stored either under refrigeration or at room temperature exposed to fluorescent light. Four samples for each storage condition were analyzed in duplicate on day zero, weekly for the first month, and then every two weeks during months 2-6. Physical stability was assessed, and the chemical stability of acetylcysteine was evaluated by high-performance liquid chromatography. Acetylcysteine solution in syringes was physically stable during the entire six-month study period. When stored at room temperature, acetylcysteine retained 99% of the original concentration at three months and 95% at six months after preparation of the syringes. Loss of acetylcysteine was <2% at six months when stored under refrigeration. Packaging acetylcysteine in batches of 100 syringes instead of preparing individual syringes reduced wastage to zero syringes, saving an estimated $247 in drug costs. The estimated pharmacy time savings was 30 hours ($702). Acetylcysteine 20% solution repackaged as 600 mg/3 mL in oral syringes is both physically and chemically stable under refrigeration or at room temperature under normal fluorescent lighting for six months. The total loss of acetylcysteine was approximately 5% at room temperature under fluorescent lighting and <2% under refrigeration. Repackaging the solution in syringes in bulk rather than in single doses demonstrated a measurable cost saving.

  11. Local anesthetic syringe ergonomics and student preferences.

    PubMed

    Wiener, R Constance; Crout, Richard J; Sandell, Joan; Howard, Brandi; Ouassa, Lydia; Wearden, Stanley; Wiener, Michael A

    2009-04-01

    With a diverse population of dentists, dental hygienists, and dental assistants, there is a wide range of sizes and shapes of individuals. Ergonomic considerations have resulted in the design of many adjustable delivery systems, chairs, and pieces of equipment. Companies have marketed instrumentation specifically for people with small hands, yet little research has been done regarding the advertising claims. The objective of this study was to compare the perceptions of dental and dental hygiene students after they used a conventional syringe and a petite syringe that has been marketed as advantageous for individuals with smaller hands. The two syringes were compared for aspiration, injection, and sense of control. A total of 181 students were invited to serve as subjects in the study, and ninety participated. The study involved two phases. During phase I, students used conventional and petite syringes to give a simulated inferior alveolar nerve block injection. In phase II, students gave a simulated palatal injection using both sizes of syringes. After performing the simulations, the students responded to a questionnaire. The students reported that the petite syringe gave them control, and 62.2 percent of them preferred it to the conventional syringe. There were differences in preferences between female and male students and also differences in preferences based on students' glove sizes. The female students preferred the petite syringe when aspiration was required. Overall, the students who wore small and extra small gloves had a preference for the petite syringe and felt it provided a sense of control, a key component when learning to provide injections.

  12. Pharmacy student knowledge, attitudes, and beliefs about selling syringes to injection drug users.

    PubMed

    Blumenthal, Wendy J; Springer, Kristen W; Jones, T Stephen; Sterk, Claire E

    2002-01-01

    To explore pharmacy school education and pharmacy students' knowledge, attitudes, and beliefs about human immunodeficiency virus (HIV) and acquired immunodeficiency syndrome (AIDS), drug use, and syringe sales to injection drug users (IDUs). Qualitative study of a convenience sample of pharmacy school students. A pharmacy school in the southeastern United States. Two focus groups and nine in-depth interviews were conducted about HIV/AIDS education and counseling, syringe sales to possible IDUs, and related pharmacy school education. 19 Doctor of Pharmacy students, including 88 students in their third professional year and 11 in their fourth professional year. Most participants believed that they would benefit from more class time on HIV/AIDS topics, including AIDS treatment medications and HIV prevention. Most participants believed that the laws and regulations governing syringe sales in their state were vague, leaving syringe sale decisions to pharmacists' discretion. Nine study participants supported selling syringes to possible IDUs, five opposed it, and five were undecided or ambivalent. Classroom education focused on addiction to prescription drugs, with limited attention to illicit drug use. Pharmacy students have divided opinions about selling syringes to IDUs. To prepare students for helping their patients with drug-use problems, pharmacy schools should increase training about HIV/AIDS and addiction. Policy makers should consider changing laws and regulations of syringe sales to recognize prevention of blood-borne infections as a legitimate medical purpose for selling syringes to IDUs.

  13. [Morphine self-administration by rats using a pneumatic syringe].

    PubMed

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  14. 21 CFR 872.6770 - Cartridge syringe.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... syringe is a device intended to inject anesthetic agents subcutaneously or intramuscularly. The device... cartridge) containing anesthetic is placed. After attaching a needle to the syringe body and activating the...

  15. 21 CFR 872.6770 - Cartridge syringe.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... syringe is a device intended to inject anesthetic agents subcutaneously or intramuscularly. The device... cartridge) containing anesthetic is placed. After attaching a needle to the syringe body and activating the...

  16. 21 CFR 872.6770 - Cartridge syringe.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... syringe is a device intended to inject anesthetic agents subcutaneously or intramuscularly. The device... cartridge) containing anesthetic is placed. After attaching a needle to the syringe body and activating the...

  17. 21 CFR 872.6770 - Cartridge syringe.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... syringe is a device intended to inject anesthetic agents subcutaneously or intramuscularly. The device... cartridge) containing anesthetic is placed. After attaching a needle to the syringe body and activating the...

  18. 21 CFR 872.6770 - Cartridge syringe.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... syringe is a device intended to inject anesthetic agents subcutaneously or intramuscularly. The device... cartridge) containing anesthetic is placed. After attaching a needle to the syringe body and activating the...

  19. Using Pharmacies in a Structural Intervention to Distribute Low Dead Space Syringes to Reduce HIV and HCV Transmission in People Who Inject Drugs

    PubMed Central

    Johnson, Terence L.; Zule, William A.; Carda-Auten, Jessica; Golin, Carol E.

    2015-01-01

    Ongoing injection drug use contributes to the HIV and HCV epidemics in people who inject drugs. In many places, pharmacies are the primary source of sterile syringes for people who inject drugs; thus, pharmacies provide a viable public health service that reduces blood-borne disease transmission. Replacing the supply of high dead space syringes with low dead space syringes could have far-reaching benefits that include further prevention of disease transmission in people who inject drugs and reductions in dosing inaccuracies, medication errors, and medication waste in patients who use syringes. We explored using pharmacies in a structural intervention to increase the uptake of low dead space syringes as part of a comprehensive strategy to reverse these epidemics. PMID:25880955

  20. Using Pharmacies in a Structural Intervention to Distribute Low Dead Space Syringes to Reduce HIV and HCV Transmission in People Who Inject Drugs.

    PubMed

    Oramasionwu, Christine U; Johnson, Terence L; Zule, William A; Carda-Auten, Jessica; Golin, Carol E

    2015-06-01

    Ongoing injection drug use contributes to the HIV and HCV epidemics in people who inject drugs. In many places, pharmacies are the primary source of sterile syringes for people who inject drugs; thus, pharmacies provide a viable public health service that reduces blood-borne disease transmission. Replacing the supply of high dead space syringes with low dead space syringes could have far-reaching benefits that include further prevention of disease transmission in people who inject drugs and reductions in dosing inaccuracies, medication errors, and medication waste in patients who use syringes. We explored using pharmacies in a structural intervention to increase the uptake of low dead space syringes as part of a comprehensive strategy to reverse these epidemics.

  1. The influence of the perceived consequences of refusing to share injection equipment among injection drug users: Balancing competing risks

    PubMed Central

    Wagner, Karla D.; Lankenau, Stephen E.; Palinkas, Lawrence A.; Richardson, Jean L.; Chou, Chih-Ping; Unger, Jennifer B.

    2011-01-01

    Injection drug users (IDUs) are at risk for HIV and other bloodborne pathogens through receptive syringe sharing (RSS) and receptive paraphernalia sharing (RPS). Research into the influence of the perceived risk of HIV infection on injection risk behavior has yielded mixed findings. One explanation may be that consequences other than HIV infection are considered when IDUs are faced with decisions about whether or not to share equipment. We investigated the perceived consequences of refusing to share injection equipment among 187 IDUs recruited from a large syringe exchange program in Los Angeles, California, assessed their influence on RSS and RPS, and evaluated gender differences. Two sub-scales of perceived consequences were identified: structural/external consequences and social/internal consequences. In multiple linear regression, the perceived social/internal consequences of refusing to share were associated with both RSS and RPS, after controlling for other psychosocial constructs and demographic variables. Few statistically significant gender differences emerged. Assessing the consequences of refusing to share injection equipment may help explain persistent injection risk behavior, and may provide promising targets for comprehensive intervention efforts designed to address both individual and structural risk factors. PMID:21498004

  2. Individual and Network Factors Associated With Prevalent Hepatitis C Infection Among Rural Appalachian Injection Drug Users

    PubMed Central

    Lofwall, Michelle R.; Frost, Simon D. W.; Oser, Carrie B.; Leukefeld, Carl G.; Crosby, Richard A.

    2013-01-01

    Objectives. We determined the factors associated with hepatitis C (HCV) infection among rural Appalachian drug users. Methods. This study included 394 injection drug users (IDUs) participating in a study of social networks and infectious disease risk in Appalachian Kentucky. Trained staff conducted HCV, HIV, and herpes simplex-2 virus (HSV-2) testing, and an interviewer-administered questionnaire measured self-reported risk behaviors and sociometric network characteristics. Results. The prevalence of HCV infection was 54.6% among rural IDUs. Lifetime factors independently associated with HCV infection included HSV-2, injecting for 5 or more years, posttraumatic stress disorder, injection of cocaine, and injection of prescription opioids. Recent (past-6-month) correlates of HCV infection included sharing of syringes (adjusted odds ratio = 2.24; 95% confidence interval = 1.32, 3.82) and greater levels of eigenvector centrality in the drug network. Conclusions. One factor emerged that was potentially unique to rural IDUs: the association between injection of prescription opioids and HCV infection. Therefore, preventing transition to injection, especially among prescription opioid users, may curb transmission, as will increased access to opioid maintenance treatment, novel treatments for cocaine dependence, and syringe exchange. PMID:23153148

  3. Cross-cultural exchange: How students can frustrate the aims of study abroad programmes

    NASA Astrophysics Data System (ADS)

    Barnes, Leslie R.

    1982-09-01

    Readily accepting that study abroad programmes may have as many differing forms and aims as there are participating institutions, and that by no means all programmes include academic content in their goals, I would nevertheless maintain: 1. that a sociological perspective is as necessary as the hitherto predominantly psychological approach in obtaining a balanced assessment of study abroad programmes;

  4. Scale-up of a comprehensive harm reduction programme for people injecting opioids: lessons from north-eastern India

    PubMed Central

    Lalmuanpuii, Melody; Biangtung, Langkham; Mishra, Ritu Kumar; Reeve, Matthew J; Tzudier, Sentimoa; Singh, Angom L; Sinate, Rebecca

    2013-01-01

    Abstract Problem Harm reduction packages for people who inject illicit drugs, including those infected with human immunodeficiency virus (HIV), are cost-effective but have not been scaled up globally. In the north-eastern Indian states of Manipur and Nagaland, the epidemic of HIV infection is driven by the injection of illicit drugs, especially opioids. These states needed to scale up harm reduction programmes but faced difficulty doing so. Approach In 2004, the Bill & Melinda Gates Foundation funded Project ORCHID to scale up a harm reduction programme in Manipur and Nagaland. Local setting In 2003, an estimated 10 000 and 16 000 people were injecting drugs in Manipur and Nagaland, respectively. The prevalence of HIV infection among people injecting drugs was 24.5% in Manipur and 8.4% in Nagaland. Relevant changes By 2012, the harm reduction programme had been scaled up to an average of 9011 monthly contacts outside clinics (80% of target); an average of 1709 monthly clinic visits (15% of target, well above the 5% monthly goal) and an average monthly distribution of needles and syringes of 16 each per programme participant. Opioid agonist maintenance treatment coverage was 13.7% and retention 6 months after enrolment was 63%. Antiretroviral treatment coverage for HIV-positive participants was 81%. Lessons learnt A harm reduction model consisting of community-owned, locally relevant innovations and business approaches can result in good harm reduction programme scale-up and influence harm reduction policy. Project ORCHID has influenced national harm reduction policy in India and contributed to the development of harm reduction guidelines. PMID:23599555

  5. HIV Infection Risk among Injection Drug Users in a Methadone Maintenance Treatment Program, Taipei, Taiwan 2007-2010

    PubMed Central

    Yen, Yung-Feng; Rodwell, Timothy C.; Yen, Muh-Yong; Hsu, Yun-Hsia; Chuang, Peing; Li, Lan-Huei; Su, Lien-Wen; Yang, Yi-Hong; Fang, Yung-Chun; Garfein, Richard S.

    2014-01-01

    Background Taiwan has a growing HIV/AIDS epidemic that has recently shifted to an increase among injection drug users (IDUs). This study aimed to measure the prevalence and incidence and identify correlates of HIV infection among IDUs in a large methadone maintenance treatment program (MMTP) in Taipei, Taiwan. Methods Data from intake interviews and HIV testing completed by IDUs upon admission to the Taipei City Hospital MMTP in 2007-2010 were included in this analysis. HIV testing was repeated semi-annually among maintained clients who were HIV-negative at admission. Results Of 1,444 IDUs admitted, 85.9% were male, median age was 40 years, and mean years of injecting was 14.3 (range: 1-64). The prevalence of HIV, HCV, and HIV/HCV co-infection was 13.4%, 91.1%, and 13.2%, respectively. In multivariable analysis, HIV infection was associated with sharing syringes during the 6 months prior to admission (OR=14.76, 95% CI 10.31-21.13), homelessness (OR=6.46, 95% CI1.49-28.00), and lifetime number of MMTP admissions (OR=1.76, 95% CI 1.30-2.38) and times incarcerated (OR=1.10, 95% CI1.03-1.18). HIV seroincidence was 1.15/100 person-years at risk (95% CI 0.62-8.77/100 PY) among IDUs who were HIV-negative at first admission. Conclusions Taiwanese IDUs in MMTP have a high HIV prevalence, which was associated with syringe sharing and other factors related to social marginalization. Our findings highlight the importance of harm reduction programs, including syringe exchange, along with HIV-prevention education. PMID:22783806

  6. Nonprescription naloxone and syringe sales in the midst of opioid overdose and hepatitis C virus epidemics: Massachusetts, 2015.

    PubMed

    Stopka, Thomas J; Donahue, Ashley; Hutcheson, Marguerite; Green, Traci C

    To determine the prevalence of nonprescription naloxone and sterile syringe sales, factors associated with nonprescription sales, geospatial access to nonprescription naloxone and syringe-selling pharmacies, and targets for potential interventions. Cross-sectional study. Massachusetts has experienced steep increases in reported opioid overdoses and hepatitis C virus cases in the past decade. Pharmacists have the potential to play a substantial role in increasing access to nonprescription naloxone and sterile syringes, which can reverse opioid overdoses and decrease hepatitis C virus transmission, respectively. We completed brief telephone surveys with 809 of 1042 retail pharmacies across Massachusetts (response rate = 77.6%) during 2015 to assess experience with nonprescription sales of naloxone and sterile syringes. Our primary outcomes were the stocking and selling of naloxone in the pharmacy (yes or no) for nonprescription sales and nonprescription syringe sales (yes or no). We conducted multivariable regression analyses and created maps using a geographic information system to identify factors associated with nonprescription sales of naloxone and sterile syringes, and to improve our understanding of geospatial access to pharmacy-based naloxone and syringe sales. More than 97% of pharmacies reported selling sterile syringes without requiring a prescription, and 45% of pharmacies reported stocking and selling naloxone. Factors associated with nonprescription sales included hours of operation, experience with and interest in harm reduction activities, and presence in an opioid overdose hotspot. Geographic access to nonprescription sale of sterile syringes is widespread, whereas geospatial access to naloxone is limited. Training to understand the benefits, applications, and distribution needs of naloxone is of interest to surveyed pharmacists. Access to sterile syringes through nonprescription sales is strong across Massachusetts, and although more than 350 pharmacies (45%) reported stocking and selling naloxone to prevent opioid overdose deaths, there is much room for improvement in access and training among pharmacy staff members. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Non-Prescription Naloxone and Syringe Sales in the Midst of Opioid Overdose and Hepatitis C Virus Epidemics: Massachusetts, 2015

    PubMed Central

    Stopka, Thomas J.; Donahue, Ashley; Hutcheson, Marguerite; Green, Traci C.

    2017-01-01

    Objectives To determine the prevalence of non-prescription naloxone and sterile syringe sales, factors associated with non-prescription sales, geospatial access to non-prescription naloxone and syringe selling pharmacies, and targets for potential interventions. Design Cross-sectional study. Setting and Participants Massachusetts has experienced steep increases in reported opioid overdoses and hepatitis C virus (HCV) cases in the past decade. Pharmacists have the potential to play a substantial role in increasing access to non-prescription naloxone and sterile syringes, which can reverse opioid overdoses and decrease HCV transmission, respectively. We completed brief telephone surveys with 809 of 1,042 retail pharmacies across Massachusetts (response rate=77.6%) during 2015 to assess experience with non-prescription sales of naloxone and sterile syringes. Outcome Measures Our primary outcomes were the stocking and selling of naloxone in the pharmacy (yes/no) for non-prescription sales, and non-prescription syringe sales (yes/no). We conducted multivariable regression analyses and created maps using a geographic information system (GIS) to identify factors associated with non-prescription sales of naloxone and sterile syringes, and to improve our understanding geospatial access to pharmacy-based naloxone and syringe sales. Results Over 97% of pharmacies reported selling sterile syringes without requiring a prescription and 45% of pharmacies reported stocking and selling naloxone. Factors associated with non-prescription sales included: hours of operation, experience with and interest in harm reduction activities, and presence in an opioid overdose hotspot. Geographic access to non-prescription sale of sterile syringes is wide-spread, while geospatial access to naloxone is more limited. Training to better understand the benefits, applications, and distribution needs of naloxone is of interest to surveyed pharmacists. Conclusion Access to sterile syringes through non-prescription sales is strong across Massachusetts and, while over 350 pharmacies (45%) reported stocking and selling naloxone to prevent opioid overdose deaths, there is much room for improvement in access, and training among pharmacy staff. PMID:28189540

  8. Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

    PubMed

    Stucki, Cyril; Sautter, Anna-Maria; Favet, Jocelyne; Bonnabry, Pascal

    2009-11-15

    The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated. Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes. Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p < 0.0001). Certain high-risk manipulations were associated with a significant increase in the contamination of the surrogate syringes, including exposure to nonsterile ambient air and nonsterile objects or fingers (p < 0.0001). High contamination rates were measured when the hub of syringes touched nonsterile environmental surfaces and fingers, whereas the drawn-air manipulation was associated with a lower risk of contamination. Working within a properly operating unidirectional airflow primary engineering control in an ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

  9. Is crime associated with over-the-counter pharmacy syringe sales? Findings from Los Angeles, California.

    PubMed

    Stopka, Thomas J; Geraghty, Estella M; Azari, Rahman; Gold, Ellen B; DeRiemer, Kathryn

    2014-03-01

    More than 50,000 new HIV infections occur annually in the United States. Injection drug users represent twelve percent of incident HIV infections each year. Pharmacy sales of over-the-counter (OTC) syringes have helped prevent HIV transmission among injection drug users in many states throughout the United States. However, concerns exist among some law enforcement officials, policymakers, pharmacists, and community members about potential links between OTC syringe sales and crime. We used a geographic information system and novel spatial and longitudinal analyses to determine whether implementation of pharmacy-based OTC syringe sales were associated with reported crime between January 2006 and December 2008 in Los Angeles Police Department Reporting Districts. We assessed reported crime pre- and post-OTC syringe sales initiation as well as longitudinal associations between crime and OTC syringe-selling pharmacies. By December 2008, 9.3% (94/1010) of Los Angeles Police Department Reporting Districts had at least one OTC syringe-selling pharmacy. Overall reported crime counts and reported crime rates decreased between 2006 and 2008 in all 1010 Reporting Districts. Using generalized estimating equations and adjusting for potential confounders, reported crime rates were negatively associated with OTC syringe sales (adjusted rate ratio: 0.89; 95% confidence interval: 0.81, 0.99). Our findings demonstrate that OTC pharmacy syringe sales were not associated with increases in reported crime in local communities in Los Angeles during 2006-2008. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Geographic approaches to quantifying the risk environment: a focus on syringe exchange program site access and drug-related law enforcement activities

    PubMed Central

    Cooper, Hannah LF; Bossak, Brian; Tempalski, Barbara; Des Jarlais, Don C.; Friedman, Samuel R.

    2009-01-01

    The concept of the “risk environment” – defined as the “space … [where] factors exogenous to the individual interact to increase the chances of HIV transmission” – draws together the disciplines of public health and geography. Researchers have increasingly turned to geographic methods to quantify dimensions of the risk environment that are both structural and spatial (e.g., local poverty rates). The scientific power of the intersection between public health and geography, however, has yet to be fully mined. In particular, research on the risk environment has rarely applied geographic methods to create neighbourhood-based measures of syringe exchange programs (SEPs) or of drug-related law enforcement activities, despite the fact that these interventions are widely conceptualized as structural and spatial in nature and are two of the most well-established dimensions of the risk environment. To strengthen research on the risk environment, this paper presents a way of using geographic methods to create neighbourhood-based measures of (1) access to SEP sites and (2) exposure to drug-related arrests, and then applies these methods to one setting (New York City). NYC-based results identified substantial cross-neighbourhood variation in SEP site access and in exposure to drug-related arrest rates (even within the subset of neighbourhoods nominally experiencing the same drug-related police strategy). These geographic measures – grounded as they are in conceptualizations of SEPs and drug-related law enforcement strategies – can help develop new arenas of inquiry regarding the impact of these two dimensions of the risk environment on injectors’ health, including exploring whether and how neighbourhood-level access to SEP sites and exposure to drug-related arrests shape a range of outcomes among local injectors. PMID:18963907

  11. Factors associated with drug-related harms related to policing in Tijuana, Mexico

    PubMed Central

    2011-01-01

    Objective To assess factors associated with drug-related harms related to policing among injection drug users (IDUs) in Tijuana, Mexico. Methods IDUs who were over 18 years old and had injected drugs within the last six months were recruited via respondent-driven sampling and underwent questionnaires and testing for HIV (human immunodeficiency virus), syphilis and TB (tuberculosis). Random effects logistic regression was used to simultaneously model factors associated with five drug-related harms related to policing practices in the prior six months (i.e., police led them to rush injections; affected where they bought drugs; affected locations where they used drugs; feared that police will interfere with their drug use; receptive syringe sharing). Results Of 727 IDUs, 85% were male; median age was 38 years. Within the last 6 months, 231 (32%) of IDUs reported that police had led them to rush injections, affected where they bought or used drugs or were very afraid police would interfere with their drug use, or shared syringes. Factors independently associated with drug-related harms related to policing within the last six months included: recent arrest, homelessness, higher frequencies of drug injection, use of methamphetamine, using the local needle exchange program and perceiving a decrease in the purity of at least one drug. Conclusions IDUs who experienced drug-related harms related to policing were those who were most affected by other micro and macro influences in the physical risk environment. Police education programs are needed to ensure that policing practices do not exacerbate risky behaviors or discourage protective behaviors such as needle exchange program use, which undermines the right to health for people who inject drugs. PMID:21477299

  12. Sterile Basics of Compounding: Relationship Between Syringe Size and Dosing Accuracy.

    PubMed

    Kosinski, Tracy M; Brown, Michael C; Zavala, Pedro J

    2018-01-01

    The purpose of this study was to investigate the accuracy and reproducibility of a 2-mL volume injection using a 3-mL and 10-mL syringe with pharmacy student compounders. An exercise was designed to assess each student's accuracy in compounding a sterile preparation with the correct 4-mg strength using a 3-mL and 10-mL syringe. The average ondansetron dose when compounded with the 3-mL syringe was 4.03 mg (standard deviation ± 0.45 mg), which was not statistically significantly different than the intended 4-mg desired dose (P=0.497). The average ondansetron dose when compounded with the 10-mL syringe was 4.18 mg (standard deviation + 0.68 mg), which was statistically significantly different than the intended 4-mg desired dose (P=0.002). Additionally, there also was a statistically significant difference in the average ondansetron dose compounded using a 3-mL syringe (4.03 mg) and a 10-mL syringe (4.18 mg) (P=0.027). The accuracy and reproducibility of the 2-mL desired dose volume decreased as the compounding syringe size increased from 3 mL to 10 mL. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  13. Efficacy trial of Camouflage Syringe to reduce dental fear and anxiety.

    PubMed

    Ujaoney, S; Mamtani, M; Thakre, T; Tote, J; Hazarey, V; Hazarey, P; Kulkarni, H

    2013-12-01

    Dental fear and anxiety in early childhood are widely prevalent and contribute to dental problems and behaviour in adulthood. Novel ways to reduce dental fear and anxiety in children are needed. Our aim was to conduct an efficacy trial of a novel Camouflage Syringe to reduce dental fear and anxiety in children. randomised controlled trial of efficacy of the Camouflage Syringe. We designed a Camouflage Syringe with a toy-like appearance that veils the conventional syringe to permit topical application and injection of local anaesthesia and ensure more involvement of the patient in the treatment process. We conducted a concurrent parallel, randomised controlled trial (NCT01398007) on the efficacy of this Camouflage Syringe to reduce the dental fear and anxiety in children seeking dental treatment who required the use of local anaesthesia. Using Venham's clinical rating scale, Venham's picture test, parental stress questionnaire and recall questionnaire, the efficacy of the Camouflage Syringe to reduce dental fear and anxiety ranged from 82% to 97% for various outcomes and from 60% to 100% for prevention of related adverse outcomes. For all outcomes, the number needed to treat was close to unity. Our results strongly favour the use of Camouflage Syringe to reduce dental fear and anxiety in children.

  14. Safety and immunogenicity of inactivated poliovirus vaccine when given with measles-rubella combined vaccine and yellow fever vaccine and when given via different administration routes: a phase 4, randomised, non-inferiority trial in The Gambia.

    PubMed

    Clarke, Ed; Saidu, Yauba; Adetifa, Jane U; Adigweme, Ikechukwu; Hydara, Mariama Badjie; Bashorun, Adedapo O; Moneke-Anyanwoke, Ngozi; Umesi, Ama; Roberts, Elishia; Cham, Pa Modou; Okoye, Michael E; Brown, Kevin E; Niedrig, Matthias; Chowdhury, Panchali Roy; Clemens, Ralf; Bandyopadhyay, Ananda S; Mueller, Jenny; Jeffries, David J; Kampmann, Beate

    2016-08-01

    The introduction of the inactivated poliovirus vaccine (IPV) represents a crucial step in the polio eradication endgame. This trial examined the safety and immunogenicity of IPV given alongside the measles-rubella and yellow fever vaccines at 9 months and when given as a full or fractional dose using needle and syringe or disposable-syringe jet injector. We did a phase 4, randomised, non-inferiority trial at three periurban government clinics in west Gambia. Infants aged 9-10 months who had already received oral poliovirus vaccine were randomly assigned to receive the IPV, measles-rubella, and yellow fever vaccines, singularly or in combination. Separately, IPV was given as a full intramuscular or fractional intradermal dose by needle and syringe or disposable-syringe jet injector at a second visit. The primary outcomes were seroprevalence rates for poliovirus 4-6 weeks post-vaccination and the rate of seroconversion between baseline and post-vaccination serum samples for measles, rubella, and yellow fever; and the post-vaccination antibody titres generated against each component of the vaccines. We did a per-protocol analysis with a non-inferiority margin of 10% for poliovirus seroprevalence and measles, rubella, and yellow fever seroconversion, and (1/3) log2 for log2-transformed antibody titres. This trial is registered with ClinicalTrials.gov, number NCT01847872. Between July 10, 2013, and May 8, 2014, we assessed 1662 infants for eligibility, of whom 1504 were enrolled into one of seven groups for vaccine interference and one of four groups for fractional dosing and alternative route of administration. The rubella and yellow fever antibody titres were reduced by co-administration but the seroconversion rates achieved non-inferiority in both cases (rubella, -4·5% [95% CI -9·5 to -0·1]; yellow fever, 1·2% [-2·9 to 5·5]). Measles and poliovirus responses were unaffected (measles, 6·8% [95% CI -1·4 to 14·9]; poliovirus serotype 1, 1·6% [-6·7 to 4·7]; serotype 2, 0·0% [-2·1 to 2·1]; serotype 3, 0·0% [-3·8 to 3·9]). Poliovirus seroprevalence was universally high (>97%) after vaccination, but the antibody titres generated by fractional intradermal doses of IPV did not achieve non-inferiority compared with full dose. The number of infants who seroconverted or had a four-fold rise in titres was also lower by the intradermal route. There were no safety concerns. The data support the future co-administration of IPV, measles-rubella, and yellow fever vaccines within the Expanded Programme on Immunization schedule at 9 months. The administration of single fractional intradermal doses of IPV by needle and syringe or disposable-syringe jet injector compromises the immunity generated, although it results in a high post-vaccination poliovirus seroprevalence. Bill & Melinda Gates Foundation. Copyright © 2016 Clarke et al. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd.. All rights reserved.

  15. Making Nasopalatine Blocks Comfortable: A Randomised Prospective Clinical Comparison of Pain Associated with the Injection Using an Insulin Syringe and a Standard Disposable 3 mL Syringe.

    PubMed

    Prabhu, Sundararaman; Faizel, Syed; Pahlajani, Vedant; Prabhu, Shweta Jha

    2013-12-01

    This study was conducted to compare and evaluate the pain associated with administration of Nasopalatine blocks using a disposable insulin syringe and the conventional disposable 3 mL syringe. Forty patients requiring intraalveolar extractions of maxillary central incisors were randomly assigned to two groups of 20 patients each; one (Group A) received the nasopalatine block with a standard 3mL syringe and the other (Group B) received the block with an insulin syringe. Patients were asked to rate the pain associated with the injection on a visual analog scale (VAS) and the results were analysed using a Chi Square Test. The mean VAS score for Group A and B was 1.55 and 1 respectively. Chi Square value was calculated to be 8.603 (degree of freedom= 3, P value= 0.0351). There were no differences in the effectiveness of anesthesia between the groups. Pain associated with administration of the nasopalatine blocks may be significantly mitigated by using the Insulin syringe.

  16. A community based approach to linking injection drug users with needed services through pharmacies: An evaluation of a pilot intervention in New York City

    PubMed Central

    Rudolph, AE; Standish, K; Amesty, S; Crawford, ND; Stern, RJ; Badillo, WE; Boyer, A; Brown, D; Ranger, N; Orduna, JM Garcia; Lasenburg, L; Lippek, Sarah; Fuller, CM

    2010-01-01

    Studies suggest that community-based approaches could help pharmacies expand their public health role, particularly pertaining to HIV prevention. Thirteen pharmacies participating in New York’s Expanded Syringe Access Program, which permits non-prescription syringe sales to reduce syringe-sharing among injection drug users (IDUs), were enrolled in an intervention to link IDU syringe customers to medical/social services. Sociodemographics, injection practices, beliefs about and experiences with pharmacy use, and medical/social service utilization were compared among 29 IDUs purchasing syringes from intervention pharmacies and 66 IDUs purchasing syringes from control pharmacies using chi-square tests. Intervention IDUs reported more positive experiences in pharmacies than controls; both groups were receptive to a greater public health pharmacist role. These data provide evidence that CBPR aided in the implementation of a pilot structural intervention to promote understanding of drug use and HIV prevention among pharmacy staff, and facilitated expansion of pharmacy services beyond syringe sales in marginalized, drug-using communities. PMID:20528131

  17. Retraction of the Plunger on a Syringe of Hyaluronic Acid Before Injection: Are We Safe?

    PubMed

    Carey, Wayne; Weinkle, Susan

    2015-12-01

    Controversy exists concerning the need for aspiration before injection with hyaluronic acid (HA) fillers. The authors undertook a study of HA products to determine if blood could be aspirated back into a syringe of HA when the needle has been primed or filled with HA. Two studies were set up to determine if or when blood could be withdrawn from a heparinized fresh tube of blood into the HA syringe. Two different techniques were tested; one using a slow-pull retraction of the plunger and up to a 5-second waiting time before release versus a rapid pullback and quick release. Review of these data demonstrates that the usual clinical method, which involves quick withdrawal and instant release of the syringe plunger does not allow for sufficient removal of the filler found intraluminal in the needle and may give rise to false negative results in vitro and likely in vivo with the exception being the Galderma/Medicis products. In summary, withdrawal of the syringe plunger with no visible blood in the syringe does not eliminate the possibility of intravascular placement of the syringe needle.

  18. Development of a Mechatronic Syringe Pump to Control Fluid Flow in a Microfluidic Device Based on Polyimide Film

    NASA Astrophysics Data System (ADS)

    Sek Tee, Kian; Sharil Saripan, Muhammad; Yap, Hiung Yin; Fhong Soon, Chin

    2017-08-01

    With the advancement in microfluidic technology, fluid flow control for syringe pump is always essential. In this paper, a mechatronic syringe pump will be developed and customized to control the fluid flow in a poly-dimethylsiloxane (PDMS) microfluidic device based on a polyimide laminating film. The syringe pump is designed to drive fluid with flow rates of 100 and 1000 μl/min which intended to drive continuous fluid in a polyimide based microfluidic device. The electronic system consists of an Arduino microcontroller board and a uni-polar stepper motor. In the system, the uni-polar stepper motor was coupled to a linear slider attached to the plunger of a syringe pump. As the motor rotates, the plunger pumps the liquid out of the syringe. The accuracy of the fluid flow rate was determined by adjusting the number of micro-step/revolution to drive the stepper motor to infuse fluid into the microfluidic device. With the precise control of the electronic system, the syringe pump could accurately inject fluid volume at 100 and 1000 μl/min into a microfluidic device.

  19. Effects of International Student Exchange on Pre-Service Teachers: A Quasi-Experimental Study

    ERIC Educational Resources Information Center

    Leutwyler, Bruno; Meierhans, Claudia

    2016-01-01

    This contribution provides empirical answers to the question of how teaching-specific competencies develop during participation in an international student exchange programme. The quantitative analyses of this quasi-experimental study suggest that, generally speaking, no specific developments occur during an exchange experience. These findings…

  20. Moving from a project to programmatic response: scaling up harm reduction in Asia.

    PubMed

    Chatterjee, Anindya; Sharma, Mukta

    2010-03-01

    The response to the HIV epidemics among people who inject drugs in Asia began to emerge in the early to mid 1990s, with the rather hesitant implementation of small-scale needle syringe programmes and community care initiatives aiming to support those who were already living with the virus. Since then Asia has seen a significant scaling up of harm reduction, despite very limited resources and difficult policy and legislative environments. One of the major reasons this has happened, is the utilisation of programme based approaches and the firm entrenchment of harm reduction thinking within national HIV/AIDS programmes and strategic plans--in most cases aided by multilateral and bilateral donors. Several models of scale up have been noted in Asia. The transition away from project based approaches, while on the whole positive, can also have a negative impact if the involvement of civil society and a client focussed approach is not protected. Also there are implications for which models of capacity building can be systematised for ongoing scale up. Most crucially, the tensions between drug policy, human rights and public health policies need to be resolved if harm reduction services are to be made available to the millions in Asia who are still unable to access these services. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  1. Syringe sociology.

    PubMed

    Vitellone, Nicole

    2015-06-01

    In this article I consider the impact of social epistemologies for understanding the object of the syringe. My aim is to examine the process through which the syringe transforms from an injecting device to a tool of social and political inquiry. Paying particular attention to the uses of Foucault, Becker, Bourdieu, Freud and Latour in empirical studies of injecting heroin use, I examine the sociology of the syringe through the lens of habit and habitus, discourse and deviance, mourning and melancholia, attachment and agencement. In pursuing the theory behind the object my goal is to address a sociological object in the making. In so doing I show how the syringe has been significant for social research, social theory, and sociology. It is the difference the object makes that this article seeks to describe. In tracing the epistemology of the syringe I show how the object is important not just for knowledge of addiction but sociology itself. © London School of Economics and Political Science 2015.

  2. Evaluating a nursing erasmus exchange experience: Reflections on the use and value of the Nominal Group Technique for evaluation.

    PubMed

    Cunningham, Sheila

    2017-09-01

    This paper discusses the use of Nominal Group Technique (NGT) for European nursing exchange evaluation at one university. The NGT is a semi-quantitative evaluation method derived from the Delphi method popular in the 1970s and 1980s. The NGT was modified from the traditional version retaining the structured cycles and but adding a broader group discussion. The NGT had been used for 2 successive years but required analysis and evaluation itself for credibility and 'fit' for purpose which is presented here. It aimed to explore nursing students' exchange experiences and aid programme development futures exchanges and closure from exchange. Results varied for the cohorts and students as participants enthusiastically engaged generating ample data which they ranked and categorised collectively. Evaluation of the NGT itself was two fold: by the programme team who considered purpose, audience, inclusivity, context and expertise. Secondly, students were asked for their thoughts using a graffiti board. Students avidly engaged with NGT but importantly also reported an effect from the process itself as an opportunity to reflect and share their experiences. The programme team concluded the NGT offered a credible evaluation tool which made use of authentic student voice and offered interactive group processes. Pedagogially, it enabled active reflection thus aiding reorientation back to the United Kingdom and awareness of 'transformative' consequences of their exchange experiences. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Pharmacy-randomized intervention delivering HIV prevention services during the syringe sale to people who inject drugs in New York City.

    PubMed

    Lewis, Crystal Fuller; Rivera, Alexis V; Crawford, Natalie D; DeCuir, Jennifer; Amesty, Silvia

    2015-08-01

    Pharmacy syringe access may be an opportunity to provide HIV prevention resources to persons who inject drugs (PWID). We examined the impact of a pharmacy-randomized intervention to reduce injection risk among PWID in New York City. Pharmacies (n=88) were randomized into intervention, primary control, and secondary control arms. Intervention pharmacies received in-depth harm reduction training, recruited syringe customers who inject drugs into the study, and provided additional services (i.e., HIV prevention/medical/social service referrals, syringe disposal containers, and harm reduction print materials). Primary control pharmacies recruited syringe customers who inject drugs and did not offer additional services, and secondary control pharmacies did not recruit syringe customers (and are not included in this analysis) but participated in a pharmacy staff survey to evaluate intervention impact on pharmacy staff. Recruited syringe customers underwent a baseline and 3-month follow-up ACASI. The intervention effect on injection risk/protective behavior of PWID was examined. A total of 482 PWID completed baseline and follow-up surveys. PWID were mostly Hispanic/Latino, male, and mean age of 43.6 years. After adjustment, PWID in the intervention arm were more likely to report always using a sterile syringe vs. not (PR=1.24; 95% CI: 1.04-1.48) at 3-month follow-up. These findings present evidence that expanded pharmacy services for PWID can encourage sterile syringe use which may decrease injection risk in high HIV burdened Black and Latino communities. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. It's hard to play ball: A qualitative study of knowledge exchange and silo effects in public health.

    PubMed

    Johnson, Rebecca; Grove, Amy; Clarke, Aileen

    2018-01-02

    Partnerships in public health form an important component of commissioning and implementing services, in England and internationally. In this research, we examine the views of staff involved in a City-wide health improvement programme which ran from 2009 to 2013 in England. We examine the practicalities of partnership work in community settings, and we describe some of barriers faced when implementing a large, multi-organisation health improvement programme. Qualitative, semi-structured interviews were performed. Purposive sampling was used to identify potential participants in the programme: programme board of directors, programme and project managers and intervention managers. Interviews were conducted one-to-one. We conducted a thematic analysis using the 'one sheet of paper' technique. This involved analysing data deductively, moving from initial to axial coding, developing categories and then identifying emerging themes. Fifteen interviews were completed. Three themes were identified. The first theme reflects how poor communication approaches hindered the ability of partnerships to deliver their aims and objectives in a range of ways and for a range of reasons. Our second theme reflects how a lack of appropriate knowledge exchange hindered decision-making, affected trust and contributed to protectionist approaches to working. This lack of shared, and communicated, understanding of what type of knowledge is most appropriate and in which circumstance made meaningful knowledge exchange challenging for decision-making and partnership-working in the City-wide health improvement programme. Theme three demonstrates how perceptions about silos in partnership-working could be problematic, but silos themselves were at times beneficial to partnerships. This revealed a mismatch between rhetoric and a realistic understanding of what components of the programme were functional and which were more hindrance than help. There were high expectations placed on the concept of what partnership work was, or how it should be done. We found our themes to be interdependent, and reflective of the 'dynamic fluid process' discussed within the knowledge mobilisation literature. We contend that reframing normal and embedded processes of silos and silo-working already in use might ease resistance to some knowledge exchange processes and contribute to better long-term functioning of public health partnerships.

  5. HIV and incarceration: prisons and detention

    PubMed Central

    2011-01-01

    The high prevalence of HIV infection among prisoners and pre-trial detainees, combined with overcrowding and sub-standard living conditions sometimes amounting to inhuman or degrading treatment in violation of international law, make prisons and other detention centres a high risk environment for the transmission of HIV. Ultimately, this contributes to HIV epidemics in the communities to which prisoners return upon their release. We reviewed the evidence regarding HIV prevalence, risk behaviours and transmission in prisons. We also reviewed evidence of the effectiveness of interventions and approaches to reduce the risk behaviours and, consequently, HIV transmission in prisons. A large number of studies report high levels of risk behaviour in prisons, and HIV transmission has been documented. There is a large body of evidence from countries around the world of what prison systems can do to prevent HIV transmission. In particular, condom distribution programmes, accompanied by measures to prevent the occurrence of rape and other forms of non-consensual sex, needle and syringe programmes and opioid substitution therapies, have proven effective at reducing HIV risk behaviours in a wide range of prison environments without resulting in negative consequences for the health of prison staff or prisoners. The introduction of these programmes in prisons is therefore warranted as part of comprehensive programmes to address HIV in prisons, including HIV education, voluntary HIV testing and counselling, and provision of antiretroviral treatment for HIV-positive prisoners. In addition, however, action to reduce overcrowding and improve conditions in detention is urgently needed. PMID:21595957

  6. HIV and incarceration: prisons and detention.

    PubMed

    Jürgens, Ralf; Nowak, Manfred; Day, Marcus

    2011-05-19

    The high prevalence of HIV infection among prisoners and pre-trial detainees, combined with overcrowding and sub-standard living conditions sometimes amounting to inhuman or degrading treatment in violation of international law, make prisons and other detention centres a high risk environment for the transmission of HIV. Ultimately, this contributes to HIV epidemics in the communities to which prisoners return upon their release. We reviewed the evidence regarding HIV prevalence, risk behaviours and transmission in prisons. We also reviewed evidence of the effectiveness of interventions and approaches to reduce the risk behaviours and, consequently, HIV transmission in prisons. A large number of studies report high levels of risk behaviour in prisons, and HIV transmission has been documented. There is a large body of evidence from countries around the world of what prison systems can do to prevent HIV transmission. In particular, condom distribution programmes, accompanied by measures to prevent the occurrence of rape and other forms of non-consensual sex, needle and syringe programmes and opioid substitution therapies, have proven effective at reducing HIV risk behaviours in a wide range of prison environments without resulting in negative consequences for the health of prison staff or prisoners.The introduction of these programmes in prisons is therefore warranted as part of comprehensive programmes to address HIV in prisons, including HIV education, voluntary HIV testing and counselling, and provision of antiretroviral treatment for HIV-positive prisoners. In addition, however, action to reduce overcrowding and improve conditions in detention is urgently needed.

  7. A clinical comparative study between conventional and camouflaged syringes to evaluate behavior and anxiety in 6-11-year-old children during local anesthesia administration-a novel approach.

    PubMed

    Melwani, Anjana M; Srinivasan, Ila; Setty, Jyothsna V; D R, Murali Krishna; Pamnani, Sunaina S; Lalitya, Dandamudi

    2018-02-01

    The sight of dental injection can bring about severe anxiety in children. Therefore, an alternative method that is convenient, effective, and keeps the needle hidden making it child friendly is necessary. The objective of the study was to compare the efficacy of a camouflaged syringe and conventional syringe on behavior and anxiety in 6-11-year-old children during local anesthesia administration. The study was a randomized, crossover clinical study including 30 children. Children were separated into two groups. Group 1 consisted of 15 children aged 6-8 years while group 2 consisted of 15 children aged 9-11 years. This study involved two sessions wherein all the children were injected using conventional and camouflaged syringes in separate sessions. Their behavior was assessed using the Faces, Legs, Activity, Cry, Consolability (FLACC) behavior pain scale and anxiety was assessed by measuring changes in pulse rate. Patient and operator preferences were compared. The results showed a lower mean change in pulse rate and FLACC scores in the camouflaged group, suggesting a positive behavior and lesser anxiety with camouflaged syringes than with conventional syringes. The use of camouflaged syringes for anesthesia was demonstrated to be effective in improving the behavior of children and decreasing their anxiety, and is therefore recommended as an alternative to the use of conventional syringes for local anesthesia.

  8. Is it ethical to invite compatible pairs to participate in exchange programmes?

    PubMed

    Fortin, Marie-Chantal

    2013-12-01

    Living kidney transplantation offers the best results for patients with end-stage renal disease (ESRD). This form of transplantation is no longer restricted to genetically or emotionally related donors, as shown by the acceptance of non-directed living anonymous donors, and the development of exchange programmes (EPs). EPs make it possible to perform living kidney transplantation among incompatible pairs, but while such programmes can help increase living organ donation, they can also create a degree of unfairness. Kidney transplant recipients in the O blood group are at a disadvantage when it comes to EPs because they can only receive organs from O donors, whereas O donors are universal donors. This poses a major challenge in terms of distributive justice and equity. A way to remedy this situation is through altruistic unbalanced paired kidney exchange (AUPKE), in which a compatible pair consisting of an O blood group donor and a non-O recipient is invited to participate in an EP. Although the AUPKE approach appears fairer for O recipients, it still raises ethical questions. How does this type of exchange affect the donor/recipient gift relationship? Should recipients in compatible pairs receive a 'better organ' than the one they would otherwise have received from their intended donor? Finally, what is the role of transplant teams in AUPKE? This article will examine the organisational and ethical challenges associated with EPs and AUPKE, and compare different EP policies in countries where such programmes exist.

  9. Video- Water Injected Into Bubble Onboard the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Saturday Morning Science, the science of opportunity series of applied experiments and demonstrations, performed aboard the International Space Station (ISS) by Expedition 6 astronaut Dr. Don Pettit, revealed some remarkable findings. In this video, Dr. Pettit demonstrates using a syringe to inject water into a bubble. The result amazed Dr. Pettit and his crew mates. They observed that the droplets may bounce around for 5 or 6 collisions within the bubble, and then may partially or all at once exchange masses with the bubble. Dr. Pettit speculates the dynamics as a possible interplay between tension forces of kinetic energy and momentum, and possibly even charged forces.

  10. Dump the pump: manual aspiration thrombectomy (MAT) with a syringe is technically effective, expeditious, and cost-efficient.

    PubMed

    Gross, Bradley A; Jadhav, Ashutosh P; Jovin, Tudor G; Jankowitz, Brian Thomas

    2018-04-01

    Syringe aspiration for manual aspiration thrombectomy (MAT) is a cost- and time-efficient alternative to an aspiration pump with likely similar efficacy. It is counterintuitive to expect the pump to perform better than direct vacuum with a syringe, as the pump must deliver vacuum additionally through a canister and meters of tubing. To present in vitro and clinical results of MAT with a syringe. An in vitro analysis was performed comparing vacuum pressures generated by syringe aspiration and with pump aspiration. This was then complemented with prospective clinical data providing details of angiographic and clinical outcomes for syringe MAT. The in vitro analysis demonstrated that equal to slightly greater vacuum pressures were generated by a 60 cc syringe as compared with the pump in both static and partial flow conditions. In our clinical series, 106/113 acute stroke thrombectomies over a 6-month period were performed with syringe MAT on the first pass. Syringe usage instead of pump tubing and a canister led to a total savings of $58 300. The rate of Thrombolysis in Cerebral Infarction 2b/3 recanalization was 93%. Adjunctive stentriever usage was performed in 23% of cases. Median puncture to reperfusion time was 25 min; mean change in National Institute of Health Stroke Scale score at 24 hours was an improvement of 5.1 (median 6). The in-hospital mortality rate was 10%. Seventy percent of patients were discharged to home (modified Rankin Scale (mRS) score 0-2) or a rehabilitation facility (mRS score 2-4). MAT using a syringe is a safe, fast, and more cost-effective approach than using an aspiration pump. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Evaluation of a new syringe presentation of reduced-antigen content diphtheria, tetanus, and acellular pertussis vaccine in healthy adolescents - A single blind randomized trial

    PubMed Central

    Pavia-Ruz, Noris; Abarca, Katia; Lepetic, Alejandro; Cervantes-Apolinar, Maria Yolanda; Hardt, Karin; Jayadeva, Girish; Kuriyakose, Sherine; Han, Htay Htay; de la O, Manuel

    2015-01-01

    Reduced-antigen-content diphtheria-tetanus-acellular pertussis (dTpa) vaccine, Boostrix™, is indicated for booster vaccination of children, adolescents and adults. The original prefilled disposable dTpa syringe presentation was recently replaced by another prefilled-syringe presentation with latex-free tip-caps and plunger-stoppers. 671 healthy adolescents aged 10–15 years who had previously received 5 or 6 previous DT(P)/dT(pa) vaccine doses, were randomized (1:1) to receive dTpa booster, injected using the new (dTpa-new) or previous syringe (dTpa-previous) presentations. Immunogenicity was assessed before and 1-month post-booster vaccination; safety/reactogenicity were assessed during 31-days post-vaccination. Non-inferiority of dTpa-new versus dTpa-previous was demonstrated for all antigens (ULs 95% CIs for GMC ratios ranged between 1.03-1.13). 1-month post-booster, immune responses were in similar ranges for all antigens with both syringe presentations. dTpa delivered using either syringe presentation was well-tolerated. These clinical results complement the technical data and support the use of the new syringe presentation to deliver the dTpa vaccine. PMID:26075317

  12. Compact Apparatus Grows Protein Crystals

    NASA Technical Reports Server (NTRS)

    Bugg, Charles E.; Delucas, Lawrence J.; Suddath, Fred L.; Snyder, Robert S.; Herren, Blair J.; Carter, Daniel C.; Yost, Vaughn H.

    1989-01-01

    Laboratory apparatus provides delicately balanced combination of materials and chemical conditions for growth of protein crystals. Apparatus and technique for growth based on hanging-drop method for crystallization of macromolecules. Includes pair of syringes with ganged plungers. One syringe contains protein solution; other contains precipitating-agent solution. Syringes intrude into cavity lined with porous reservoir material saturated with 1 mL or more of similar precipitating-agent solution. Prior to activation, ends of syringes plugged to prevent transport of water vapor among three solutions.

  13. Design and Synthesis of Network-Forming Triblock Copolymers Using Tapered Block Interfaces

    PubMed Central

    Kuan, Wei-Fan; Roy, Raghunath; Rong, Lixia; Hsiao, Benjamin S.; Epps, Thomas H.

    2012-01-01

    We report a strategy for generating novel dual-tapered poly(isoprene-b-isoprene/styrene-b-styrene-b-styrene/methyl methacrylate-b-methyl methacrylate) [P(I-IS-S-SM-M)] triblock copolymers that combines anionic polymerization, atom transfer radical polymerization (ATRP), and Huisgen 1,3-dipolar cycloaddition click chemistry. The tapered interfaces between blocks were synthesized via a semi-batch feed using programmable syringe pumps. This strategy allows us to manipulate the transition region between copolymer blocks in triblock copolymers providing control over the interfacial interactions in our nanoscale phase-separated materials independent of molecular weight and block constituents. Additionally, we show the ability to retain a desirous and complex multiply-continuous network structure (alternating gyroid) in our dual-tapered triblock material. PMID:23066522

  14. Vacuum aspiration with the IPAS Modified Gynecologic Syringe.

    PubMed

    Balogh, S A

    1983-01-01

    The IPAS Modified Gynecologic Syringe was compared with the electric pump and standard hand pump in a clinical trial of 1227 women undergoing vacuum aspiration. This modified double-valve syringe was designed to fit larger 8 mm, 10 mm and 12 mm cannulae, which are more suitable for late first trimester procedures. The study was conducted at four centers in which the double-valve syringe was used alternately with the vacuum source normally used at each clinic. Although there were notable inter-center differences with respect to certain outcome variables, results were similar for procedures performed at the same center. The only significant finding was the lower proportion of women requiring D & C to complete uterine evacuation among double-valve syringe patients than among hand pump cases at one center. The data indicate that the double-valve syringe is safe and effective for uterine aspiration in women up to 14 weeks' gestation and may be preferable for use in clinics with limited facilities.

  15. Plausible authentication of manuka honey and related products by measuring leptosperin with methyl syringate.

    PubMed

    Kato, Yoji; Fujinaka, Rie; Ishisaka, Akari; Nitta, Yoko; Kitamoto, Noritoshi; Takimoto, Yosuke

    2014-07-09

    Manuka honey, obtained from Leptospermum scoparium flowers in New Zealand, has strong antibacterial properties. In this study, plausible authentication of the manuka honey was inspected by measuring leptosperin, methyl syringate 4-O-β-D-gentiobiose, along with methyl syringate. Despite a gradual decrease in methyl syringate content over 30 days at 50 °C, even at moderate 37 °C, leptosperin remained stable. A considerable correlation between nonperoxide antibacterial activity and leptosperin content was observed in 20 certified manuka honey samples. Leptosperin and methyl syringate in manuka honey and related products were analyzed using HPLC connected with mass spectrometry. One noncertified brand displayed significant variations in the leptosperin and methyl syringate contents between two samples obtained from different regions. Therefore, certification is clearly required to protect consumers from disguised and/or low-quality honey. Because leptosperin is stable during storage and specific to manuka honey, its measurement may be applicable for manuka honey authentication.

  16. Needle and syringe sharing among Iranian drug injectors

    PubMed Central

    Rafiey, Hassan; Narenjiha, Hooman; Shirinbayan, Peymaneh; Noori, Roya; Javadipour, Morteza; Roshanpajouh, Mohsen; Samiei, Mercedeh; Assari, Shervin

    2009-01-01

    Objective The role of needle and syringe sharing behavior of injection drug users (IDUs) in spreading of blood-borne infections – specially HIV/AIDS – is well known. However, very little is known in this regard from Iran. The aim of our study was to determine the prevalence and associates of needle and syringe sharing among Iranian IDUs. Methods In a secondary analysis of a sample of drug dependents who were sampled from medical centers, prisons and streets of the capitals of 29 provinces in the Iran in 2007, 2091 male IDUs entered. Socio-demographic data, drug use data and high risk behaviors entered to a logistic regression to determine independent predictors of lifetime needle and syringe sharing. Results 749(35.8%) reported lifetime experience of needle and syringe sharing. The likelihood of lifetime needle and syringe sharing was increased by female gender, being jobless, having illegal income, drug use by family members, pleasure/enjoyment as causes of first injection, first injection in roofless and roofed public places, usual injection at groin, usual injection at scrotum, lifetime experience of nonfatal overdose, and history of arrest in past year and was decreased by being alone at most injections. Conclusion However this data has been extracted from cross-sectional design and we can not conclude causation, some of the introduced variables with association with needle and syringe sharing may be used in HIV prevention programs which target reducing syringe sharing among IDUs. PMID:19643014

  17. CHANGES IN LIPID-ENCAPSULATED MICROBUBBLE POPULATION DURING CONTINUOUS INFUSION AND METHODS TO MAINTAIN CONSISTENCY

    PubMed Central

    KAYA, MEHMET; GREGORY, THOMAS S.; DAYTON, PAUL A.

    2009-01-01

    Stabilized microbubbles are utilized as ultrasound contrast agents. These micron-sized gas capsules are injected into the bloodstream to provide contrast enhancement during ultrasound imaging. Some contrast imaging strategies, such as destruction-reperfusion, require a continuous injection of microbubbles over several minutes. Most quantitative imaging strategies rely on the ability to administer a consistent dose of contrast agent. Because of the buoyancy of these gas-filled agents, their spatial distribution within a syringe changes over time. The population of microbubbles that is pumped from a horizontal syringe outlet differs from initial population as the microbubbles float to the syringe top. In this manuscript, we study the changes in the population of a contrast agent that is pumped from a syringe due to microbubble floatation. Results are presented in terms of change in concentration and change in mean diameter, as a function of time, suspension medium, and syringe diameter. Data illustrate that the distribution of contrast agents injected from a syringe changes in both concentration and mean diameter over several minutes without mixing. We discuss the application of a mixing system and viscosity agents to keep the contrast solution more evenly distributed in a syringe. These results are significant for researchers utilizing microbubble contrast agents in continuous-infusion applications where it is important to maintain consistent contrast agent delivery rate, or in situations where the injection syringe cannot be mixed immediately prior to administration. PMID:19632760

  18. Giving an insulin injection

    MedlinePlus

    ... of Insulin To fill a syringe with one type of insulin: Wash your hands with soap and water. Dry them well. Check ... hand, and tap the syringe with your other hand. The bubbles will float to the top. Push the bubbles back into the ... To fill a syringe with two ...

  19. Variability in syringe components and its impact on functionality of delivery systems.

    PubMed

    Rathore, Nitin; Pranay, Pratik; Eu, Bruce; Ji, Wenchang; Walls, Ed

    2011-01-01

    Prefilled syringes and autoinjectors are becoming increasingly common for parenteral drug administration primarily due to the convenience they offer to the patients. Successful commercialization of such delivery systems requires thorough characterization of individual components. Complete understanding of various sources of variability and their ranking is essential for robust device design. In this work, we studied the impact of variability in various primary container and device components on the delivery forces associated with syringe injection. More specifically, the effects of barrel size, needle size, autoinjector spring force, and frictional forces have been evaluated. An analytical model based on underlying physics is developed that can be used to fully characterize the design space for a product delivery system. Use of prefilled syringes (syringes prefilled with active drug) is becoming increasingly common for injectable drugs. Compared to vials, prefilled syringes offer higher dose accuracy and ease of use due to fewer steps required for dosage. Convenience to end users can be further enhanced through the use of prefilled syringes in combination with delivery devices such as autoinjectors. These devices allow patients to self-administer the drug by following simple steps such as pressing a button. These autoinjectors are often spring-loaded and are designed to keep the needle tip shielded prior to injection. Because the needle is not visible to the user, such autoinjectors are perceived to be less invasive than syringes and help the patient overcome the hesitation associated with self-administration. In order to successfully develop and market such delivery devices, we need to perform an in-depth analysis of the components that come into play during the activation of the device and dose delivery. Typically, an autoinjector is activated by the press of a button that releases a compressed spring; the spring relaxes and provides the driving force to push the drug out of the syringe and into the site of administration. Complete understanding of the spring force, syringe barrel dimensions, needle size, and drug product properties is essential for robust device design. It is equally important to estimate the extent of variability that exists in these components and the resulting impact it could have on the performance of the device. In this work, we studied the impact of variability in syringe and device components on the delivery forces associated with syringe injection. More specifically, the effect of barrel size, needle size, autoinjector spring force, and frictional forces has been evaluated. An analytical model based on underlying physics is developed that can be used to predict the functionality of the autoinjector.

  20. Doxycycline hyclate-loaded bleached shellac in situ forming microparticle for intraperiodontal pocket local delivery.

    PubMed

    Phaechamud, Thawatchai; Chanyaboonsub, Nuttapong; Setthajindalert, Orn

    2016-10-10

    Bleached shellac (BS) is a water-insoluble polyester resin made up of sesquiterpenoid acids esterified with hydroxy aliphatic acids. In this study, BS dissolved in N-methyl pyrrolidone (NMP), dimethyl sulfoxide (DMSO) and 2-pyrrolidone was used as the internal phase of oil in oil emulsion using olive oil emulsified with glyceryl monostearate (GMS) as the external phase of in situ forming microparticles (ISM). Doxycycline hyclate (DH)-loaded BS ISMs were tested for emulsion stability, viscosity, rheology, transformation into microparticles, syringeability, drug release, surface topography, in vitro degradation and antimicrobial activities against Staphylococcus aureus, Streptococcus mutans and Porphyromonas gingivalis. All emulsions exhibited pseudoplastic flow and notably low syringeability force. Slower transformation from emulsion into microparticles of ISM prepared with 2-pyrrolidone was owing to slower solvent exchange of this solvent which promoted less porous structure of obtained BS matrix microparticles. The system containing 2-pyrrolidone exhibited a higher degradability than that prepared with DMSO. Developed DH-loaded BS ISMs exhibited a sustainable drug release for 47days with Fickian diffusion and effectively inhibited P. gingivalis, S. mutans and S. aureus. Therefore a DH-loaded BS ISM using olive oil containing GMS as the external phase and 2-pyrrolidone as a solvent was a suitable formulation for periodontitis treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Solute-Filled Syringe For Formulating Intravenous Solution

    NASA Technical Reports Server (NTRS)

    Owens, Jim; Bindokas, AL; Dudar, Tom; Finley, Mike; Scharf, Mike

    1993-01-01

    Prefilled syringe contains premeasured amount of solute in powder or concentrate form used to deliver solute to sterile interior of large-volume parenteral (LVP) bag. Predetermined amount of sterile water also added to LVP bag through sterilizing filter, and mixed with contents of syringe, yielding sterile intravenous solution of specified concentration.

  2. 21 CFR 870.1670 - Syringe actuator for an injector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Syringe actuator for an injector. 870.1670 Section 870.1670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1670 Syringe...

  3. Designing, Constructing, and Using an Inexpensive Electronic Buret

    ERIC Educational Resources Information Center

    Cao, Tingting; Zhang, Qing; Thompson, Jonathan E.

    2015-01-01

    A syringe-based, electronic fluid dispenser is described. The device mechanically connects a syringe plunger to a linear slide potentiometer. As the syringe plunger moves, the electrical resistance between terminals of the potentiometer varies. Application and subsequent measurement of a DC voltage between the potentiometer pins is used to track…

  4. 21 CFR 870.1670 - Syringe actuator for an injector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Syringe actuator for an injector. 870.1670 Section 870.1670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1670 Syringe...

  5. A Self-Contained Pole Syringe Array for Closed-Interval Water Sampling.

    DTIC Science & Technology

    1982-10-19

    L AD-R12l 265 R SELF-CONTAINED POLE SYRINGE ARRAY FOR CLOSDITRR Va WATER SANPLING4U) NAVAL RESEARCH LAB WASHINGTON DC I R E PELLENBARG ET AL. 19 OCT...PERIOD COVERED A SELF-CONTAINED POLE SYRINGE ARRAY FOR Interim report on one phase of CLOSED-INTERVAL WATER SAMPLING an NRL problem. 6. PERFORMING ORG...1473 EDITION OF I NOv ,, IS OMSOLCT S/N 0102-014- 6601 SECURITY CLASSIFICATION OF THIS PAGE (Wm Dle Et ere d A SELF-CONTAINED POLE SYRINGE ARRAY FOR

  6. Police training to align law enforcement and HIV prevention: preliminary evidence from the field.

    PubMed

    Beletsky, Leo; Agrawal, Alpna; Moreau, Bruce; Kumar, Pratima; Weiss-Laxer, Nomi; Heimer, Robert

    2011-11-01

    Having identified gaps in implementation of Rhode Island's syringe access law and police occupational safety education, public health and police professionals developed police training to boost legal knowledge, improve syringe access attitudes, and address needlestick injuries. Baseline data (94 officers) confirmed anxiety about needlestick injuries, poor legal knowledge, and occupational risk overestimation. Before training, respondents believed that syringe access promotes drug use (51%), increases likelihood of police needlestick injuries (58%), and fails to reduce epidemics (38%). Pretraining to posttraining evaluation suggested significant shifts in legal and occupational safety knowledge; changes in attitudes toward syringe access were promising. Training that combines occupational safety with syringe access content can help align law enforcement with public health goals. Additional research is needed to assess street-level effect and to inform intervention tailoring.

  7. Hydrodynamic comparison of the Penumbra system and commonly available syringes in forced-suction thrombectomy.

    PubMed

    Simon, Scott Douglas; Grey, Casey Paul

    2014-04-01

    The Penumbra system uses a coaxial separator and continuous extracorporeal suction to remove a clot from a cerebral artery. Forced-suction thrombectomy (FST) involves aspirating clots through the same reperfusion catheter using only a syringe, decreasing the procedure time and supplies needed. To evaluate multiple combinations of catheters and syringes to determine the optimal pairing for use in FST. Tests were performed using both the Penumbra system and syringes to aspirate water through Penumbra 0.041 inch (041), 4Max, 0.054 inch (054) and 5Max reperfusion catheters and a shuttle sheath. Dynamic pressure and flow at the catheter tip were calculated from the fill times for each system. Static pressure and force for each aspiration source were determined with a vacuum gauge. All syringes provided significantly higher dynamic pressure at the catheter tip than the Penumbra system (p<0.001). Increasing syringe volume significantly increased static pressure (p<0.001). Both flow and aspiration force significantly increased with catheter size (p<0.001). Cases are presented to demonstrate the clinical value of the laboratory principles. Maximizing static and dynamic pressure when performing FST is achieved by aspirating with a syringe possessing both the largest volume and the largest inlet diameter available. Maximizing aspiration force and flow rate is achieved by using the largest catheter possible.

  8. Liquid drugs and high dead space syringes may keep HIV and HCV prevalence high - a comparison of Hungary and Lithuania.

    PubMed

    Gyarmathy, V Anna; Neaigus, Alan; Li, Nan; Ujhelyi, Eszter; Caplinskiene, Irma; Caplinskas, Saulius; Latkin, Carl A

    2010-01-01

    Despitevery similar political, drug policy and HIV prevention backgrounds, HIV and HCV prevalence is considerably different in Hungary (low HIV and moderate HCV prevalence) and Lithuania (high HCV and moderate HIV prevalence). Wecompared the drug use profile of Hungarian (n = 215) and Lithuanian (n = 300) injecting drug users (IDUs). Overall, compared with IDUs in Hungary, IDUs in Lithuania often injected opiates purchased in liquid form ('shirka'), used and shared 2-piece syringes (vs. 1-piece syringes) disproportionately more often, were less likely to acquire their syringes from legal sources and had significantly more experience with injected and less experience with non-injected drugs. It may not be liquid drugs per se that contribute to a higher prevalence of HCV and/or HIV, but it is probably factors associated with the injecting of liquid drugs, such as the wide-spread use and sharing of potentially contaminated 2-piece syringes acquired often from non-legal sources, and syringe-mediated drug sharing with 2-piece syringes. Scaling up substitution therapy, especially heroin replacement, combined with reducing the supply of liquid drugs may decrease the prevalence of high-risk injecting behaviours related to the injecting of liquid drugs and drug injecting-related infections among IDUs in Lithuania. Copyright © 2010 S. Karger AG, Basel.

  9. Evaluation of nonprescription syringe sales in San Francisco.

    PubMed

    Rose, Valerie J; Raymond, H Fisher

    2010-01-01

    To determine the experiences, practices, and challenges associated with nonprescription syringe sales (NPSS) among pharmacists whose pharmacies were enrolled in the Disease Prevention Demonstration Project in San Francisco, CA. Self-administered survey mailed to 69 pharmacies and interviews with pharmacists and technicians. A total of 55 of 69 pharmacies (80%) returned the survey, and eight pharmacy managers and three pharmacy technicians were interviewed in person. Of pharmacists, 72% reported none or very few problems with NPSS in the previous year, although surveys and interviews illustrated challenges associated with NPSS in terms of time management, educating patients about syringe disposal, and understanding patient preferences for syringes. Of pharmacists, 62% reported NPSS to no more than 10 to 20 patients per week and 67% collected more than 400 syringes in the previous year. One-third of pharmacists perceived that their pharmacies were located in areas where drug activity was high and that the majority of NPSS patients injected illegal drugs. Access to sterile syringes is a prominent public health issue, and pharmacists can play an important role in injection drug user (IDU) education and disease prevention. This evaluation suggests that pharmacies are selling nonprescription syringes to individuals perceived to be IDUs with no major problems. Additional evaluations from health department programs are needed to demonstrate the efficacy of NPSS in California.

  10. Investigating Liquid Leak from Pre-Filled Syringes upon Needle Shield Removal: Effect of Air Bubble Pressure.

    PubMed

    Chan, Edwin; Maa, Yuh-Fun; Overcashier, David; Hsu, Chung C

    2011-01-01

    This study is to investigate the effect of headspace air pressure in pre-filled syringes on liquid leak (dripping) from the syringe needle upon needle shield removal. Drip tests to measure drip quantity were performed on syringes manually filled with 0.5 or 1.0 mL of various aqueous solutions. Parameters assessed included temperature (filling and test), bulk storage conditions (tank pressure and the type of the pressurized gas), solution composition (pure water, 0.9% sodium chloride, and a monoclonal antibody formulation), and testing procedures. A headspace pressure analyzer was used to verify the drip test method. Results suggested that leakage is indeed caused by headspace pressure increase, and the temperature effect (ideal gas expansion) is a major, but not the only, factor. The dissolved gases in the liquid bulk prior to or during filling may contribute to leakage, as these gases could be released into the headspace due to solubility changes (in response to test temperature and pressure conditions) and cause pressure increase. Needle shield removal procedures were found to cause dripping, but liquid composition played little role. Overall, paying attention to the processing history (pressure and temperature) of the liquid bulk is the key to minimize leakage. The headspace pressure could be reduced by decreasing liquid bulk storage pressure, filling at a higher temperature, or employing lower solubility gas (e.g., helium) for bulk transfer and storage. Leakage could also be mitigated by simply holding the syringe needle pointing upward during needle shield removal. Substantial advances in pre-filled syringe technology development, particularly in syringe filling accuracy, have been made. However, there are factors, as subtle as how the needle shield (or tip cap) is removed, that may affect dosing accuracy. We recently found that upon removal of the tip cap from a syringe held vertically with needle pointed downwards, a small amount of solution, up to 3-4% of the 1 mL filled volume or higher for filled volume of <1 mL, leaked out from the needle. This paper identified the root causes of this problem and offered solutions from the perspectives of the syringe fill process and the end user procedure. The readers will benefit from this paper by understanding how each process step prior to and during syringe filling may affect delivery performance of the pre-filled syringe device.

  11. Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes.

    PubMed

    Del Carmen Plancha-Mansanet, Maria; Caballero-Calabuig, Elisa; Félix-Fontestad, Jesús; Reyes-Ojeda, María Dolores; Sopena-Novales, Pablo; Abreu-Sánchez, Pedro; Del Carmen Cano-Terol, Maria; Sopena-Monforte, Ramón

    2008-12-01

    Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.

  12. Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV).

    PubMed

    Jarrahian, Courtney; Rein-Weston, Annie; Saxon, Gene; Creelman, Ben; Kachmarik, Greg; Anand, Abhijeet; Zehrung, Darin

    2017-03-27

    Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered. Copyright © 2017 PATH. Published by Elsevier Ltd.. All rights reserved.

  13. Syringe confiscation as an HIV risk factor: the public health implications of arbitrary policing in Tijuana and Ciudad Juarez, Mexico.

    PubMed

    Beletsky, Leo; Lozada, Remedios; Gaines, Tommi; Abramovitz, Daniela; Staines, Hugo; Vera, Alicia; Rangel, Gudelia; Arredondo, Jaime; Strathdee, Steffanie A

    2013-04-01

    Female sex workers who inject drugs (FSW-IDUs) face elevated risk for HIV/STIs and constitute a key population for public health prevention. Through direct and indirect pathways including human rights violations, policing practices like syringe confiscation can compound FSW-IDU health risk and facilitate the spread of disease. We studied correlates of experiencing syringe confiscation among FSW-IDUs in northern Mexico, where formal policy allows for syringes to be available over the counter without a prescription, but police practices are often at odds with the law. FSW-IDUs reporting recent syringe sharing and unprotected sex with clients in Tijuana and Ciudad Juarez were administered surveys and HIV/STI testing. Logistic regression was used to identify correlates of syringe confiscation. Among 624 respondent FSW-IDUs, prevalence of syringe confiscation in the last 6 months was 48%. The following factors were positively associated with syringe confiscation: testing positive for HIV (adjusted odds ratio [aOR] = 2.54, 95% confidence interval [CI] = 1.11-5.80), reporting sexual abuse by police (aOR = 12.76, 95% CI = 6.58-24.72), engaging in groin injection (aOR = 1.84, 95% CI = 1.15-2.93), injecting in public (aOR = 1.64; 95% CI = 1.14-2.36), and obtaining syringes from pharmacies (aOR = 1.54; 95% CI = 1.06-2.23). Higher education level was negatively associated with syringe confiscation (aOR = 0.92, 95% CI = 0.87-0.98) as was frequent injection with clients within the last month (aOR = 0.64, 95% CI = 0.44-0.94). This analysis adds to the body of evidence linking unauthorized law enforcement actions targeting high-risk groups with HIV and other adverse health outcomes. Using a public health lens to conceptualize abuse as a structural risk factor, we advocate for multi-prong prevention, systematic monitoring, and evidence-based intervention response to deleterious police practices.

  14. Effect of Legal Status of Pharmacy Syringe Sales on Syringe Purchases by Persons Who Inject Drugs in San Francisco and San Diego, CA

    PubMed Central

    Siddiqui, Saira S.; Armenta, Richard; Evans, Jennifer L.; Yu, Michelle; Cuevas-Mota, Jazmine; Page, Kimberly; Davidson, Peter; Garfein, Richard S.

    2015-01-01

    Sharing blood-contaminated syringes is the main risk factor for acquiring and transmitting blood-borne infections among persons who inject drugs (PWID). To reduce this risk, in 2005, California enacted legislation allowing local health jurisdictions to legalize non-prescription syringe sales after approving a disease prevention demonstration project (DPDP). With San Francisco approving a DPDP immediately and San Diego never approving one, we compared PWID across cities for their use of pharmacies PWID to obtain syringes. PWID age 18–30 years old were recruited into separate studies in San Francisco (n=243) and San Diego (n=338) between 2008 and 2011. We used multivariable logistic regression to compare the proportions of PWID who obtained syringes from pharmacies by city while controlling for socio-demographics, injection practices and other risk behaviors. Overall, most PWID were white (71%), male (63%), and between the ages of 18–25 years (55%). Compared to San Francisco, a smaller proportion of PWID in San Diego had bought syringes from pharmacies in the prior three months (16.9% vs. 49.8%; p<0.001), which remained statistically significant after adjusting for socio-demographic and behavioral factors (adjusted odds ratio=4.45, 95% confidence interval: 2.98, 6.65). Use of pharmacies to obtain syringes was greater where it was legal to do so. Public health policy can influence HIV and hepatitis C associated risk among PWID; however, implementation of these policies is crucial for the benefits to be realized. PMID:26252980

  15. Attitudes of North Carolina law enforcement officers toward syringe decriminalization

    PubMed Central

    Davis, Corey S.; Johnston, Jill; Zerden, Lisa de Saxe; Clark, Katie; Castillo, Tessie; Childs, Robert

    2015-01-01

    Background North Carolina, like much of the U.S. South, is disproportionately affected by HIV and hepatitis. This persistently high disease burden may be driven in part by laws that criminalize the possession and distribution of syringes for illicit drug use. Legal change to decriminalize syringes may reduce infection rates in the state, but is unlikely absent support from law enforcement actors. Methods We analyzed the responses of 350 North Carolina law enforcement officers to a confidential, anonymous survey. The survey instrument collected data regarding self-reported needle-stick injury (NSI), blood borne disease risk perception and attitudes toward syringe decriminalization. Results 82% of respondents reported that contracting HIV was a “big concern” for them. 3.8% of respondents reported ever receiving a job-related NSI, a rate of 36 NSI per 10,000 officer-years. Majorities of respondents reported positive views regarding syringe decriminalization, with approximately 63% agreeing that it would be “good for the community” and 60% agreeing that it would be “good for law enforcement.” Black and female officers were significantly less likely to agree that on-the-job NSI was a “big concern” and significantly more likely to agree that it would be good for law enforcement. Conclusions These findings suggest that many North Carolina LEOs understand the public health benefits of syringe access programs and may be inclined to support syringe decriminalization legislation. Further research is indicated to determine the causes of observed differences in perceptions of bloodborne disease risk and attitudes toward syringe decriminalization by race and sex. PMID:25193720

  16. Attitudes of North Carolina law enforcement officers toward syringe decriminalization.

    PubMed

    Davis, Corey S; Johnston, Jill; de Saxe Zerden, Lisa; Clark, Katie; Castillo, Tessie; Childs, Robert

    2014-11-01

    North Carolina, like much of the U.S. South, is disproportionately affected by HIV and hepatitis. This persistently high disease burden may be driven in part by laws that criminalize the possession and distribution of syringes for illicit drug use. Legal change to decriminalize syringes may reduce infection rates in the state, but is unlikely absent support from law enforcement actors. We analyzed the responses of 350 North Carolina law enforcement officers to a confidential, anonymous survey. The survey instrument collected data regarding self-reported needle-stick injury (NSI), blood borne disease risk perception and attitudes toward syringe decriminalization. 82% of respondents reported that contracting HIV was a "big concern" for them. 3.8% of respondents reported ever receiving a job-related NSI, a rate of 36 NSI per 10,000 officer-years. Majorities of respondents reported positive views regarding syringe decriminalization, with approximately 63% agreeing that it would be "good for the community" and 60% agreeing that it would be "good for law enforcement." Black and female officers were significantly less likely to agree that on-the-job NSI was a "big concern" and significantly more likely to agree that it would be good for law enforcement. These findings suggest that many North Carolina LEOs understand the public health benefits of syringe access programs and may be inclined to support syringe decriminalization legislation. Further research is indicated to determine the causes of observed differences in perceptions of bloodborne disease risk and attitudes toward syringe decriminalization by race and sex. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Effect of legal status of pharmacy syringe sales on syringe purchases by persons who inject drugs in San Francisco and San Diego, CA.

    PubMed

    Siddiqui, Saira S; Armenta, Richard F; Evans, Jennifer L; Yu, Michelle; Cuevas-Mota, Jazmine; Page, Kimberly; Davidson, Peter; Garfein, Richard S

    2015-11-01

    Sharing blood-contaminated syringes is the main risk factor for acquiring and transmitting blood-borne infections among persons who inject drugs (PWID). To reduce this risk, in 2005, California enacted legislation allowing local health jurisdictions to legalize non-prescription syringe sales after approving a disease prevention demonstration project (DPDP). With San Francisco approving a DPDP immediately and San Diego never approving one, we compared PWID across cities for their use of pharmacies PWID to obtain syringes. PWID age 18-30 years old were recruited into separate studies in San Francisco (n=243) and San Diego (n=338) between 2008 and 2011. We used multivariable logistic regression to compare the proportions of PWID who obtained syringes from pharmacies by city while controlling for sociodemographics, injection practices and other risk behaviors. Overall, most PWID were White (71%), male (63%), and between the ages of 18-25 years (55%). Compared to San Francisco, a smaller proportion of PWID in San Diego had bought syringes from pharmacies in the prior three months (16.9% vs. 49.8%; p<0.001), which remained statistically significant after adjusting for sociodemographic and behavioral factors (adjusted odds ratio=4.45, 95% confidence interval: 2.98, 6.65). Use of pharmacies to obtain syringes was greater where it was legal to do so. Public health policy can influence HIV and hepatitis C associated risk among PWID; however, implementation of these policies is crucial for the benefits to be realized. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Are major reductions in new HIV infections possible with people who inject drugs? The case for low dead-space syringes in highly affected countries.

    PubMed

    Zule, William A; Cross, Harry E; Stover, John; Pretorius, Carel

    2013-01-01

    Circumstantial evidence from laboratory studies, mathematical models, ecological studies and bio behavioural surveys, suggests that injection-related HIV epidemics may be averted or reversed if people who inject drugs (PWID) switch from using high dead-space to using low dead-space syringes. In laboratory experiments that simulated the injection process and rinsing with water, low dead space syringes retained 1000 times less blood than high dead space syringes. In mathematical models, switching PWID from high dead space to low dead space syringes prevents or reverses injection-related HIV epidemics. No one knows if such an intervention is feasible or what effect it would have on HIV transmission among PWID. Feasibility studies and randomized controlled trials (RCTs) will be needed to answer these questions definitively, but these studies will be very expensive and take years to complete. Rather than waiting for them to be completed, we argue for an approach similar to that used with needle and syringe programs (NSP), which were promoted and implemented before being tested more rigorously. Before implementation, rapid assessments that involve PWID will need to be conducted to ensure buy-in from PWID and other local stakeholders. This commentary summarizes the existing evidence regarding the protective effects of low dead space syringes and estimates potential impacts on HIV transmission; it describes potential barriers to transitioning PWID from high dead space to low dead space needles and syringes; and it presents strategies for overcoming these barriers. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Influence of Syringe Volume on Foam Stability in Sclerotherapy for Varicose Vein Treatment.

    PubMed

    Bai, Taoping; Jiang, Wentao; Fan, Yubo

    2018-05-01

    Despite the popularity of sclerotherapy for treating varicose veins, it still exhibits various problems, such as pulmonary embolism, deep-vein thrombosis, phlebitis, and visual disorders. To investigate syringe volume influence on foam stability, obtain the foam decay rule, and provide a reference for clinics. Five types of syringes are used to prepare foam at room temperature with various liquid-gas ratios. Foam decay process experiments were performed 5 times and recorded by video. The stability indices used include drainage time, half-life, bubble diameter, bubble surface density, and drainage rate. The 30 and 2-mL syringes, respectively, recorded the highest and lowest drainage speeds. Foam drainage time and half-life, differences varied between 15 and 70 seconds, and 20 and 100 seconds, respectively. Foam bubble diameters were distributed over 0.1 to 2.0 mm with roughly 200 to 700 bubbles per square centimeter. Increased syringe volume causes the bubble diameter to increase. Thus, foam dispersion increases and foam half-life decreases; hence, foam becomes unstable. It is, thus, better to use a small syringe several times to prepare foam in clinics using segmented injections.

  20. Police Training to Align Law Enforcement and HIV Prevention: Preliminary Evidence From the Field

    PubMed Central

    Agrawal, Alpna; Moreau, Bruce; Kumar, Pratima; Weiss-Laxer, Nomi; Heimer, Robert

    2011-01-01

    Having identified gaps in implementation of Rhode Island's syringe access law and police occupational safety education, public health and police professionals developed police training to boost legal knowledge, improve syringe access attitudes, and address needlestick injuries. Baseline data (94 officers) confirmed anxiety about needlestick injuries, poor legal knowledge, and occupational risk overestimation. Before training, respondents believed that syringe access promotes drug use (51%), increases likelihood of police needlestick injuries (58%), and fails to reduce epidemics (38%). Pretraining to posttraining evaluation suggested significant shifts in legal and occupational safety knowledge; changes in attitudes toward syringe access were promising. Training that combines occupational safety with syringe access content can help align law enforcement with public health goals. Additional research is needed to assess street-level effect and to inform intervention tailoring. PMID:21940924

  1. A simple device to convert a small-animal PET scanner into a multi-sample tissue and injection syringe counter.

    PubMed

    Green, Michael V; Seidel, Jurgen; Choyke, Peter L; Jagoda, Elaine M

    2017-10-01

    We describe a simple fixture that can be added to the imaging bed of a small-animal PET scanner that allows for automated counting of multiple organ or tissue samples from mouse-sized animals and counting of injection syringes prior to administration of the radiotracer. The combination of imaging and counting capabilities in the same machine offers advantages in certain experimental settings. A polyethylene block of plastic, sculpted to mate with the animal imaging bed of a small-animal PET scanner, is machined to receive twelve 5-ml containers, each capable of holding an entire organ from a mouse-sized animal. In addition, a triangular cross-section slot is machined down the centerline of the block to secure injection syringes from 1-ml to 3-ml in size. The sample holder is scanned in PET whole-body mode to image all samples or in one bed position to image a filled injection syringe. Total radioactivity in each sample or syringe is determined from the reconstructed images of these objects using volume re-projection of the coronal images and a single region-of-interest for each. We tested the accuracy of this method by comparing PET estimates of sample and syringe activity with well counter and dose calibrator estimates of these same activities. PET and well counting of the same samples gave near identical results (in MBq, R 2 =0.99, slope=0.99, intercept=0.00-MBq). PET syringe and dose calibrator measurements of syringe activity in MBq were also similar (R 2 =0.99, slope=0.99, intercept=- 0.22-MBq). A small-animal PET scanner can be easily converted into a multi-sample and syringe counting device by the addition of a sample block constructed for that purpose. This capability, combined with live animal imaging, can improve efficiency and flexibility in certain experimental settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Freeze-drying in novel container system: Characterization of heat and mass transfer in glass syringes.

    PubMed

    Patel, Sajal M; Pikal, Michael J

    2010-07-01

    This study is aimed at characterizing and understanding different modes of heat and mass transfer in glass syringes to develop a robust freeze-drying process. Two different holder systems were used to freeze-dry in syringes: an aluminum (Al) block and a plexiglass holder. The syringe heat transfer coefficient was characterized by a sublimation test using pure water. Mannitol and sucrose (5% w/v) were also freeze-dried, as model systems, in both the assemblies. Dry layer resistance was determined from manometric temperature measurement (MTM) and product temperature was measured using thermocouples, and was also determined from MTM. Further, freeze-drying process was also designed using Smart freeze-dryer to assess its application for freeze-drying in novel container systems. Heat and mass transfer in syringes were compared against the traditional container system (i.e., glass tubing vial). In the Al block, the heat transfer was via three modes: contact conduction, gas conduction, and radiation with gas conduction being the dominant mode of heat transfer. In the plexiglass holder, the heat transfer was mostly via radiation; convection was not involved. Also, MTM/Smart freeze-drying did work reasonably well for freeze-drying in syringes. When compared to tubing vials, product temperature decreases and hence drying time increases in syringes. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  3. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    PubMed

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  4. Comparative evaluation of the amount of debris extruded apically using conventional syringe, passive ultrasonic irrigation and EndoIrrigator Plus system: An in vitro study

    PubMed Central

    Shetty, Vidhi Prabhakar; Naik, Balaram Damodar; Pachlag, Amit Kashinath; Yeli, Mahantesh Mrityunjay

    2017-01-01

    Aim: The aim of this study is to compare the effects of conventional syringe, passive ultrasonic irrigation (PUI), and EndoIrrigator Plus on the amount of apically extruded debris. Materials and Methods: Thirty extracted human mandibular premolars were selected and randomly assigned to three groups (n = 10). The root canals were irrigated with conventional syringe, PUI, and EndoIrrigator Plus. Sodium hypochlorite was used as an irrigant, and debris was collected in a previously described experimental model (Myers and Montgomery 1991). It was then stored in an incubator at 37°C for 10 days to evaporate the irrigant before weighing the dry debris. The mean weight of debris was assessed, one-way analysis of variance was used for comparison of values, and post hoc Tukey's test was used between groups (P = 0.05). Results: The EndoIrrigator Plus group extruded significantly less debris than PUI and conventional syringe groups (P < 0.05). Furthermore, PUI group extruded significantly less debris than conventional syringe irrigation group (P < 0.05). Conclusions: 1. All the three irrigation systems were associated with apical extrusion of debris, 2. EndoIrrigator Plus system extruded significantly less debris than the PUI system and the conventional syringe irrigation system, 3. PUI system extruded significantly less debris than the conventional syringe irrigation system. PMID:29430092

  5. Community Impact of Pharmacy-Randomized Intervention to Improve Access to Syringes and Services for Injection Drug Users

    ERIC Educational Resources Information Center

    Crawford, Natalie D.; Amesty, Silvia; Rivera, Alexis V.; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M.

    2014-01-01

    Objectives: In an effort to reduce HIV transmission among injection drug users (IDUs), New York State deregulated pharmacy syringe sales in 2001 through the Expanded Syringe Access Program by removing the requirement of a prescription. With evidence suggesting pharmacists' ability to expand their public health role, a structural, pharmacy-based…

  6. Stability of cyclosporine solutions stored in polypropylene-polyolefin bags and polypropylene syringes.

    PubMed

    Li, Mengqing; Forest, Jean-Marc; Coursol, Christian; Leclair, Grégoire

    2011-09-01

    The stability of cyclosporine diluted to 0.2 or 2.5 mg/mL with 0.9% sodium chloride injection or 5% dextrose injection and stored in polypropylene-polyolefin containers or polypropylene syringes was evaluated. Intravenous cyclosporine solutions (0.2 and 2.5 mg/mL) were aseptically prepared and transferred to 250-mL polypropylene-polyolefin bags or 60-mL polypropylene syringes. Chemical stability was measured using a stability-indicating high-performance liquid chromatography (HPLC) assay. Physical stability was assessed by visual inspection and a dynamic light scattering (DLS) method. After 14 days, HPLC assay showed that the samples of i.v. cyclosporine stored in polypropylene-polyolefin bags remained chemically stable (>98% of initial amount remaining); the physical stability of the samples was confirmed by DLS and visual inspection. The samples stored in polypropylene syringes were found to contain an impurity (attributed to leaching of a syringe component by the solution) that could be detected by HPLC after 1 day; on further investigation, no leaching was detected when the syringes were exposed to undiluted i.v. cyclosporine 50 mg/mL for 10 minutes. Samples of i.v. cyclosporine solutions of 0.2 and 2.5 mg/mL diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 25 °C in polypropylene-polyolefin bags were physically and chemically stable for at least 14 days. When stored in polypropylene syringes, the samples were contaminated by an impurity within 1 day; however, the short-term (i.e., ≤10 minutes) use of the syringes for the preparation and transfer of i.v. cyclosporine solution is considered safe.

  7. Movement control during aspiration with different injection systems via video monitoring-an in vitro model.

    PubMed

    Kämmerer, P W; Schneider, D; Pacyna, A A; Daubländer, M

    2017-01-01

    The aim of the present study was an evaluation of movement during double aspiration by different manual syringes and one computer-controlled local anesthesia delivery system (C-CLAD). With five different devices (two disposable syringes (2, 5 ml), two aspirating syringes (active, passive), one C-CLAD), simulation of double aspiration in a phantom model was conducted. Two experienced and two inexperienced test persons carried out double aspiration with the injection systems at the right and left phantom mandibles in three different inclination angles (n = 24 × 5 × 2 for each system). 3D divergences of the needle between aspiration procedures (mm) were measured with two video cameras. An average movement for the 2-ml disposal syringe of 2.85 mm (SD 1.63), for the 5 ml syringe of 2.36 mm (SD 0.86), for the active-aspirating syringe of 2.45 mm (SD 0.9), for the passive-aspirating syringe of 2.01 mm (SD 0.7), and for the C-CLAD, an average movement of 0.91 mm (SD 0.63) was seen. The movement was significantly less for the C-CLAD compared to the other systems (p < 0.001). The movement of the needle in the soft tissue was significantly less for the C-CLAD compared to the other systems (p < 0.001). A difference in involuntary movement of the syringe could be seen in comparison between manual and C-CLAD systems. Launching the aspiration by a foot pedal in computer-assisted anesthesia leads to a minor movement. To solve the problem of movement during aspiration with possibly increased false-negative results, a C-CLAD seems to be favorable.

  8. Lab-In-Syringe automation of stirring-assisted room-temperature headspace extraction coupled online to gas chromatography with flame ionization detection for determination of benzene, toluene, ethylbenzene, and xylenes in surface waters.

    PubMed

    Horstkotte, Burkhard; Lopez de Los Mozos Atochero, Natalia; Solich, Petr

    2018-06-22

    Online coupling of Lab-In-Syringe automated headspace extraction to gas chromatography has been studied. The developed methodology was successfully applied to surface water analysis using benzene, toluene, ethylbenzene, and xylenes as model analytes. The extraction system consisted of an automatic syringe pump with a 5 mL syringe into which all solutions and air for headspace formation were aspirated. The syringe piston featured a longitudinal channel, which allowed connecting the syringe void directly to a gas chromatograph with flame ionization detector via a transfer capillary. Gas injection was achieved via opening a computer-controlled pinch valve and compressing the headspace, upon which separation was initialized. Extractions were performed at room temperature; yet sensitivity comparable to previous work was obtained by high headspace to sample ratio V HS /V Sample of 1.6:1 and injection of about 77% of the headspace. Assistance by in-syringe magnetic stirring yielded an about threefold increase in extraction efficiency. Interferences were compensated by using chlorobenzene as an internal standard. Syringe cleaning and extraction lasting over 10 min was carried out in parallel to the chromatographic run enabling a time of analysis of <19 min. Excellent peak area repeatabilities with RSD of <4% when omitting and <2% RSD when using internal standard corrections on 100 μg L -1 level were achieved. An average recovery of 97.7% and limit of detection of 1-2 μg L -1 were obtained in analyses of surface water. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Longitudinal analysis of change in individual-level needle and syringe coverage amongst a cohort of people who inject drugs in Melbourne, Australia.

    PubMed

    O'Keefe, Daniel; Scott, Nick; Aitken, Campbell; Dietze, Paul

    2017-07-01

    Needle and syringe program (NSP) coverage is often calculated at the individual level. This method relates sterile needle and syringe acquisition to injecting frequency, resulting in a percentage of injecting episodes that utilise a sterile syringe. Most previous research using this method was restricted by their cross-sectional design, calling for longitudinal exploration of coverage. We used the data of 518 participants from an ongoing cohort of people who inject drugs in Melbourne, Australia. We calculated individual-level syringe coverage for the two weeks prior to each interview, then dichotomised the outcome as either "sufficient" (≥100% of injecting episodes covered by at least one reported sterile syringe) or "insufficient" (<100%). Time-variant predictors of change in recent coverage (from sufficient to insufficient coverage) were estimated longitudinally using logistic regression with fixed effects for each participant. Transitioning to methamphetamine injection (AOR:2.16, p=0.004) and a newly positive HCV RNA test result (AOR:4.93, p=0.001) were both associated with increased odds of change to insufficient coverage, whilst change to utilising NSPs as the primary source of syringe acquisition (AOR: 0.41, p=0.003) and opioid substitution therapy (OST) enrolment (AOR:0.51, p=0.013) were protective against a change to insufficient coverage. We statistically tested the transitions between time-variant exposure sub-groups and transitions in individual-level syringe coverage. Our results give important insights into means of improving coverage at the individual level, suggesting that methamphetamine injectors should be targeted, whilst both OST prescription and NSP should be expanded. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. [Development of Biliary Contrast Agents Remote Pushing Device].

    PubMed

    Zhu, Haoyang; Dong, Dinghui; Luo, Yu; Ren, Fenggang; Zhang, Jing; Tan, Wenjun; Shi, Aihua; Hu, Liangshuo; Wu, Rongqian; Lyu, Yi

    2018-01-30

    A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.

  11. Drugs given by a syringe driver: a prospective multicentre survey of palliative care services in the UK.

    PubMed

    Wilcock, Andrew; Jacob, Jayin K; Charlesworth, Sarah; Harris, Elayne; Gibbs, Margaret; Allsop, Helen

    2006-10-01

    The use of a syringe driver to administer drugs by continuous subcutaneous infusion is common practice in the UK. Over time, drug combinations used in a syringe driver are likely to change and the aim of this survey was to obtain a more recent snapshot of practice. On four separate days, at two-week intervals, a questionnaire was completed for every syringe driver in use by 15 palliative care services. Of 336 syringe drivers, the majority contained either two or three drugs, but one-fifth contained only one drug. The median (range) volume of the infusions was 15 (9.5-48) mL, and duration of infusion was generally 24 hours. Only one combination was reported as visually incompatible, and there were 13 site reactions (4% of total). Laboratory physical and chemical compatibility data are available for less than half of the most frequently used combinations.

  12. Plastic-Syringe Induced Silicone Contamination in Organic Photvoltaic Fabrication: Implications for Small-Volume Additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, John A.; Nalwa, Kanwar S.; Mahadevapuram, Rakesh

    Herein, the implications of silicone contamination found in solution-processed conjugated polymer solar cells are explored. Similar to a previous work based on molecular cells, we find this contamination as a result of the use of plastic syringes during fabrication. However, in contrast to the molecular case, we find that glass-syringe fabricated devices give superior performance than plastic-syringe fabricated devices in poly(3-hexylthiophene)-based cells. We find that the unintentional silicone addition alters the solution’s wettability, which translates to a thinner, less absorbent film on spinning. With many groups studying the effects of small-volume additives, this work should be closely considered as manymore » of these additives may also directly alter the solutions’ wettability, or the amount of silicone dissolved off the plastic syringes, or both. Thereby, film thickness, which generally is not reported in detail, can vary significantly from device to device.« less

  13. Syringe Decriminalization Advocacy in Red States: Lessons from the North Carolina Harm Reduction Coalition.

    PubMed

    Cloud, David H; Castillo, Tessie; Brinkley-Rubinstein, Lauren; Dubey, Manisha; Childs, Robert

    2018-05-08

    Syringe access programs (SAPs) are cornerstone harm reduction interventions for combatting the national opioid epidemic. The goal of this paper is to describe effective advocacy strategies for enacting syringe decriminalization legislation to foster the expansion of SAPs in high-need areas amidst political opposition. Decades or research shows that SAPs prevent the transmission of HIV among people who inject drugs (PWID) and are a cost-effective tool for linking PWID to medical care, health education, and social services. In the USA, state laws criminalizing distribution and possession of syringes impede the expansion of SAPs into areas where they are sorely needed. In 2016, North Carolina became the first state to legalize SAPs with a Republican super majority. This paper distills strategies for community organizations seeking to advance syringe decriminalization legislation in politically conservative states with histories of prioritizing punitive sanctions over public health responses to drug use.

  14. Subcutaneous morphine infusion by syringe driver for terminally ill patients.

    PubMed

    Cools, H J; Berkhout, A M; De Bock, G H

    1996-05-01

    The study aimed to find whether subcutaneous morphine administration by syringe driver for terminally ill patients in a Dutch nursing home led to higher morphine doses and earlier death than routine morphine administration. The data comprised the files of all patients dying over a 2 year period in a 355-bed nursing home in Delft in the Netherlands. Thirty-eight per cent of the patients had been given morphine, 29% by continuous subcutaneous syringe driver. In comparing the patients given morphine with and without a syringe driver no differences emerged in mean age, sex, length of admission, type of ward, diagnosis, duration of morphine administration and mean dose. The data indicate that subcutaneous morphine administration by syringe driver decreases dose frequency problems and improves the control of pain and other symptoms in the last week before death. There was no evidence that administration of morphine in this way shortens survival.

  15. The Potential of Dual-Language Cross-Cultural Peer Review

    ERIC Educational Resources Information Center

    Ruecker, Todd

    2011-01-01

    This article explores the potential of dual-language cross-cultural peer review and how it improves on traditional monolingual and monocultural peer review. Drawing on scholarship related to international exchange programmes, peer review, and two-way immersion programmes in the United States as well as data collected while facilitating the…

  16. Science Across the World in Teacher Training

    ERIC Educational Resources Information Center

    Schoen, Lida; Weishet, Egbert; Kennedy, Declan

    2007-01-01

    Science Across the World is an exchange programme between schools world-wide. It has two main components: existing resources for students (age 6-10) and a database with all participating schools. The programme exists since 1990. It is carried out in partnership with the British Association of Science Education (ASE) and international…

  17. Can Vocational Programmes Change Use and Exchange Value Attributions of School Leavers: A Kenyan Case Study?

    ERIC Educational Resources Information Center

    Saunders, Murray; Sambili, Helen

    1995-01-01

    A survey of Kenyan school leavers (200 responses) and 34 interviews show that the exchange value of school-leaving exams is predominant and the use value of vocational programs has little impact. Apparently, 80% of school effort has actual exchange value for only 20% of school leavers, whereas 20% of effort directed at self-employment has…

  18. The Rebirth of Educational Exchange: Anglo-German University Level Youth Exchange Programmes after the Second World War

    ERIC Educational Resources Information Center

    Naumann, Cindy

    2007-01-01

    In the early years of the Second World War the British had already begun post-war planning for education in Germany. They expressed a need to re-educate Germans and re-establish personal contacts with German people. One tool conceived to achieve these policy objectives was educational exchange. This paper will examine British educational exchange…

  19. [Critical infusion incident caused by incorrect use of a patient-controlled analgesia pump].

    PubMed

    Steffen, M; von Hintzenstern, U; Obermayer, A

    2002-01-01

    We report on the case of a 17-year-old male patient who received a PCA pump after nephrectomy for postoperative analgesia. The syringe of the PCA pump was filled with 50 mg morphine and positioned about 25 cm above the heart. Since the piston of the syringe was not bolted while the pump was switched off, an unnoticed accidental evacuation of the whole content of the syringe into the intravenous line of the patient occurred because of gravity. This problem exists not only with PCA pumps, but can happen with syringe pumps in general. The incident, which can only be explained by strongly reduced venous pressure, was detected by chance. No harm resulted for the patient, but under different conditions it could have been lethal. This critical incident was caused by various factors: incorrect application in combination with insufficient experience or training, stress, inadequate handing-over of the patient and a lack of arrangements and instructions for procedures in routine situations. Suggestions for preventing such dangerous critical incidents are made and discussed. In particular, an algorithm for the correct procedure when inserting or changing the syringe of a syringe pump is presented.

  20. Sterilizable syringes: excessive risk or cost-effective option?

    PubMed Central

    Battersby, A.; Feilden, R.; Nelson, C.

    1999-01-01

    In recent years, many poorer countries have chosen to use disposable instead of sterilizable syringes. Unfortunately, the infrastructure and management systems that are vital if disposables are to be used safely do not exist. WHO estimates that up to 30% of injections administered are unsafe. The traditional sterilizable syringe had many disadvantages, some of which have been minimized through better design and the use of modern materials; others have been overcome because staff are able to demonstrate that they have performed safely. For example, the time-steam saturation-temperature (TST) indicator has enabled staff to demonstrate that a sterilizing cycle has been successfully completed. Health facility staff must be able to sterilize equipment, and the sterilizable syringe remains the least costly means of administering an injection. Data from countries that have acceptable systems for processing clinical waste indicate that safe and environmentally acceptable disposal, destruction and final containment cost nearly as much as the original cost of a disposable syringe. By careful supervision of staff behaviour and good management, some countries have demonstrated that they are able to administer safe injections with sterilizable syringes at a price they can afford. PMID:10593029

  1. Syringe Port: A Convenient, Safe, and Cost-Effective Tubular Retractor for Transportal Removal of Deep-Seated Lesions of the Brain.

    PubMed

    Singh, Harnarayan; Patir, Rana; Vaishya, Sandeep; Miglani, Rahul; Kaur, Amandeep

    2018-06-01

    Minimally invasive transportal resection of deep intracranial lesions has become a widely accepted surgical technique. Many disposable, mountable port systems are available in the market for this purpose, like the ViewSite Brain Access System. The objective of this study was to find a cost-effective substitute for these systems. Deep-seated brain lesions were treated with a port system made from disposable syringes. The syringe port could be inserted through minicraniotomies placed and planned with navigation. All deep-seated lesions like ventricular tumours, colloid cysts, deep-seated gliomas, and basal ganglia hemorrhages were treated with this syringe port system and evaluated for safety, operative site hematomas, and blood loss. 62 patients were operated on during the study period from January 2015 to July 2017, using this innovative syringe port system for deep-seated lesions of the brain. No operative site hematoma or contusions were seen along the port entry site and tract. Syringe port is a cost-effective and safe alternative to the costly disposable brain port systems, especially for neurosurgical setups in developing countries for minimally invasive transportal resection of deep brain lesions. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Syringe Sharing in Drug Injecting Dyads: A Cross-Classified Multilevel Analysis of Social Networks.

    PubMed

    Shahesmaeili, Armita; Mirzazadeh, Ali; McFarland, Willi; Sharifi, Hamid; Haghdoost, Ali Akbar; Soori, Hamid

    2018-05-15

    We examined the association of dyadic-level factors with syringe sharing among people who inject drugs (PWID) in Kerman, Iran. In a cross-sectional study, we collected data on 329 drug-injecting dyads by individual face-to-face interviews. An injecting dyad was defined as 2 PWID who knew each other and injected drugs together during the last 6 months. If they reported at least 1 occasion of syringe sharing, the dyad was considered high-risk. Dyadic-level factors associated with syringe sharing were assessed using cross-classified multilevel logistic regression. The rate of syringe sharing was significantly higher for dyads who were more intimate (adjusted odds ratio [AOR] 4.5, CI 95%, 2.3-8.6), who had instrumental support (AOR 2.1, 95% CI 1.1-4.5), and who pooled money for drugs (AOR 4.1, 95% CI 2.0-8.3). The rate was lower in same-sex dyads (AOR 0.4, 95% CI 0.2-0.9) and in dyads who shared health information (AOR 0.5, 95% CI 0.2-0.9). Findings highlight close-peer influences on syringe-sharing behavior.

  3. ‘Safer Environment Interventions’: A qualitative synthesis of the experiences and perceptions of people who inject drugs

    PubMed Central

    McNeil, Ryan; Small, Will

    2014-01-01

    There is growing acknowledgment that social, structural, and environmental forces produce vulnerability to health harms among people who inject drugs (PWID), and safer environment interventions (SEI) have been identified as critical to mitigating the impacts of these contextual forces on drug-related harm. To date, however, SEIs have been under-theorized in the literature, and how they minimize drug-related risks across intervention types and settings has not been adequately examined. This article presents findings from a systematic review and meta-synthesis of qualitative studies reporting PWID’s experiences with three types of SEIs (syringe exchange programmes, supervised injection facilities and peer-based harm reduction interventions) published between 1997 and 2012. This meta-synthesis seeks to develop a comprehensive understanding of SEIs informed by the experiences of PWID. Twenty-nine papers representing twenty-one unique studies that included an aggregate of more than 800 PWID were included in this meta-synthesis. This meta- synthesis found that SEIs fostered social and physical environments that mitigated drug-related harms and increased access to social and material resources. Specifically, SEIs: (1) provided refuge from street-based drug scenes; (2) enabled safer injecting by reshaping the social and environmental contexts of injection drug use; (3) mediated access to resources and health care services; and, (4) were constrained by drug prohibition and law enforcement activities. These findings indicate that it is critical to situate SEIs in relation to the lived experiences of PWID, and in particular provide broader environmental support to PWID. Given that existing drug laws limit the effectiveness of interventions, drug policy reforms are needed to enable public health, and specifically SEIs, to occupy a more prominent role in the response to injection drug use. PMID:24561777

  4. A survey of bloodborne viruses and associated risk behaviours in Greek prisons.

    PubMed

    Malliori, M; Sypsa, V; Psichogiou, M; Touloumi, G; Skoutelis, A; Tassopoulos, N; Hatzakis, A; Stefanis, C

    1998-02-01

    To determine HIV and hepatitis infection prevalence and correlates with risk behaviour. Cross-sectional study: voluntary, anonymous HIV, hepatitis (HCV, HBV and HDV) surveillance and questionnaire on risk factors. Korydallos Prison, Athens and Ag. Stefanos Prison, Patra, Greece. Of 544 drug users imprisoned for drug related offences, all completed the questionnaire and 533 blood samples were collected. HIV (by anti-HIV-1), HCV (by anti-HCV), HBV (by anti-HBc, HBsAg) and HDV (by anti-HDV) prevalence. Data on demography, legal status, drug use, sharing of injecting equipment. Of the 544 drug users, 375 (68.9%) had injected drugs (IDUs) at some time, 35% of whom had injected whilst in that prison. Of the 533 blood samples tested, one was positive for anti-HIV-1 (0.19%), 310 for anti-HCV (58.2%), 306/531 (57.6%) for anti-HBc, 34/527 (6.5%) for HBsAg and 12/527 (2.3%) for anti-HDV. Prevalence rates for IDUs only were 0.27% for HIV-1, 80.6% for hepatitis C, 62.7% for hepatitis B and 3.3% for hepatitis D. Ninety-two per cent of IDUs injecting in prison shared needles, indicating that IDUs inject less but share more during incarceration. Multiple logistic regression revealed needle-sharing as the most important risk factor for HCV infection in IDUs. Prior knowledge of a positive hepatitis result did not appear to inhibit IDUs from practising risky behaviours in prison. The epidemic of hepatitis B and C among imprisoned IDUs identified by this study constitutes a major public health problem. Prevention programmes, such as counselling, HBV vaccination, community-based methadone maintenance treatment and syringe exchange schemes, are necessary in order to prevent a further spread.

  5. Client-Level Coverage of Needle and Syringe Program and High-Risk Injection Behaviors: A Case Study of People Who Inject Drugs in Kermanshah, Iran.

    PubMed

    Noroozi, Mehdi; Mirzazadeh, Ali; Noroozi, Alireza; Mehrabi, Yadoallah; Hajebi, Ahmad; Zamani, Saman; Sharifi, Hamid; Higgs, Peter; Soori, Hamid

    2015-01-01

    Needle-syringe programs (NSP) have been running in Iran since 2002. However, the coverage of such program among the NSP clients at the individual level was not studies yet. This study aimed to determine the client coverage of NSP and its correlation with high injection-related risk behaviors. A cross-sectional survey was conducted in Kermanshah province, Iran, in 2014. 230 people who inject drugs (PWID) recruited from two drop-in centers (DICs) from April to September 2014, participated in a face-to-face interview to provide information related individual coverage of NSP, demographic characteristics, and injecting behaviors 30 days prior to the interview. Overall, the average of syringe coverage was 158% [95% confidence interval (CI) = 65.7-205.5], while 56% (95% CI = 40-97) have individual converge less than 100%. Needle/syringe sharing was significantly higher among individual with low NSP coverage [adjusted odds ratio (AOR) = 2.6, 95% CI = 1.3-6.2]. About 85% participants with coverage of less than 100% reported reuse of syringe within the last 30 days (AOR = 3.2, 95% CI = 1.4-7.7). PWID are different regarding their NSP individual-level converges. There are certain clusters of PWID, who do not receive sufficient number of syringes. Given that insufficient individual syringe coverage level is highly associated with injection risk behaviors, reasons for such low converge need to be assessed and addressed carefully.

  6. Client-Level Coverage of Needle and Syringe Program and High-Risk Injection Behaviors: A Case Study of People Who Inject Drugs in Kermanshah, Iran

    PubMed Central

    Noroozi, Mehdi; Mirzazadeh, Ali; Noroozi, Alireza; Mehrabi, Yadoallah; Hajebi, Ahmad; Zamani, Saman; Sharifi, Hamid; Higgs, Peter; Soori, Hamid

    2015-01-01

    Background Needle-syringe programs (NSP) have been running in Iran since 2002. However, the coverage of such program among the NSP clients at the individual level was not studies yet. This study aimed to determine the client coverage of NSP and its correlation with high injection-related risk behaviors. Methods A cross-sectional survey was conducted in Kermanshah province, Iran, in 2014. 230 people who inject drugs (PWID) recruited from two drop-in centers (DICs) from April to September 2014, participated in a face-to-face interview to provide information related individual coverage of NSP, demographic characteristics, and injecting behaviors 30 days prior to the interview. Findings Overall, the average of syringe coverage was 158% [95% confidence interval (CI) = 65.7-205.5], while 56% (95% CI = 40-97) have individual converge less than 100%. Needle/syringe sharing was significantly higher among individual with low NSP coverage [adjusted odds ratio (AOR) = 2.6, 95% CI = 1.3-6.2]. About 85% participants with coverage of less than 100% reported reuse of syringe within the last 30 days (AOR = 3.2, 95% CI = 1.4-7.7). Conclusion PWID are different regarding their NSP individual-level converges. There are certain clusters of PWID, who do not receive sufficient number of syringes. Given that insufficient individual syringe coverage level is highly associated with injection risk behaviors, reasons for such low converge need to be assessed and addressed carefully. PMID:26885353

  7. Novel Technique for Rebubbling DMEK Grafts at the Slit Lamp Using Intravenous Extension Tubing.

    PubMed

    Sáles, Christopher S; Straiko, Michael D; Terry, Mark A

    2016-04-01

    To describe a novel technique for rebubbling DMEK grafts at the slit lamp using a cannula coupled to a syringe with intravenous (IV) extension tubing. We present a retrospective case series of eyes that underwent rebubbling using a novel technique at the slit lamp. The rebubbling apparatus is assembled using a standard 43-inch IV extension tube, a 5-cc luer lock syringe, and a 27-gauge cannula. The cannula is screwed onto one end of the extension tubing, and a 5-cc syringe that has been filled with air is screwed onto the opposite end. With the patient seated at the slit lamp, the cannula is positioned in the anterior chamber by the surgeon with one hand while the other hand operates the syringe and the joystick. We performed 5 rebubbling procedures at the slit lamp using a standard syringe and cannula. Despite suboptimal ergonomics with this approach, all of these cases achieved sufficient air fills without any complications. Four rebubbling procedures were subsequently performed at the slit lamp using our novel rebubbling technique. All of these cases also attained sufficient air fills without complications, but they were noted to be much easier to perform by the surgeon. Using IV extension tubing to couple a syringe to a cannula for rebubbling DMEK grafts at the slit lamp is ergonomically superior to the conventional alternative of using a standard cannula on a syringe. The technique is also simple and inexpensive to adopt.

  8. Access to healthcare insurance and healthcare services among syringe exchange program clients in Massachusetts: qualitative findings from health navigators with the iDU ("I do") Care Collaborative.

    PubMed

    Stopka, Thomas J; Hutcheson, Marguerite; Donahue, Ashley

    2017-05-18

    Little is known about access to health insurance among people who inject drugs (PWID) who attend syringe exchange programs (SEPs). The goal of the current study was to assess perceptions of SEP staff, including health navigators and program managers, on access to health insurance and healthcare access among SEP clients following implementation of state and federal policies to enhance universal healthcare access in Massachusetts. Between December 2014 and January 2015, we conducted in-depth interviews (n = 14) with SEP staff, including both program managers and health navigators, to assess knowledge, attitudes, and beliefs related to health insurance enrollment and access to enhanced referrals among SEP clients. We developed a preliminary coding scheme from the interview guide and used a grounded theory approach to guide inclusion of subsequent thematic codes that emanated from the data. We analyzed the coded data thematically in an iterative fashion using a consensus-based approach. We identified five primary themes that emerged from the qualitative interviews, including high levels of health insurance enrollment among SEP clients; barriers to enrolling in health insurance; highly needed referrals to services, including improved access to substance use disorder treatment and hepatitis C virus treatment; barriers to referring clients to these highly needed services; and recommendations for policy change. While barriers to enrollment and highly needed referrals remain, access to and enrollment in healthcare insurance plans among PWID at SEPs in Massachusetts are high. With the uncertain stability of the Affordable Care Act following the US presidential election of 2016, our findings summarize the opportunities and challenges that are connected to health insurance and healthcare access in Massachusetts. SEPs can play an important role in facilitating access to health insurance and enhancing access to preventive health and primary care.

  9. A complex systems approach to evaluate HIV prevention in metropolitan areas: preliminary implications for combination intervention strategies.

    PubMed

    Marshall, Brandon D L; Paczkowski, Magdalena M; Seemann, Lars; Tempalski, Barbara; Pouget, Enrique R; Galea, Sandro; Friedman, Samuel R

    2012-01-01

    HIV transmission among injecting and non-injecting drug users (IDU, NIDU) is a significant public health problem. Continuing propagation in endemic settings and emerging regional outbreaks have indicated the need for comprehensive and coordinated HIV prevention. We describe the development of a conceptual framework and calibration of an agent-based model (ABM) to examine how combinations of interventions may reduce and potentially eliminate HIV transmission among drug-using populations. A multidisciplinary team of researchers from epidemiology, sociology, geography, and mathematics developed a conceptual framework based on prior ethnographic and epidemiologic research. An ABM was constructed and calibrated through an iterative design and verification process. In the model, "agents" represent IDU, NIDU, and non-drug users who interact with each other and within risk networks, engaging in sexual and, for IDUs, injection-related risk behavior over time. Agents also interact with simulated HIV prevention interventions (e.g., syringe exchange programs, substance abuse treatment, HIV testing) and initiate antiretroviral treatment (ART) in a stochastic manner. The model was constructed to represent the New York metropolitan statistical area (MSA) population, and calibrated by comparing output trajectories for various outcomes (e.g., IDU/NIDU prevalence, HIV prevalence and incidence) against previously validated MSA-level data. The model closely approximated HIV trajectories in IDU and NIDU observed in New York City between 1992 and 2002, including a linear decrease in HIV prevalence among IDUs. Exploratory results are consistent with empirical studies demonstrating that the effectiveness of a combination of interventions, including syringe exchange expansion and ART provision, dramatically reduced HIV prevalence among IDUs during this time period. Complex systems models of adaptive HIV transmission dynamics can be used to identify potential collective benefits of hypothetical combination prevention interventions. Future work will seek to inform novel strategies that may lead to more effective and equitable HIV prevention strategies for drug-using populations.

  10. Awareness of pre-exposure prophylaxis (PrEP) among women who inject drugs in NYC: the importance of networks and syringe exchange programs for HIV prevention.

    PubMed

    Walters, Suzan M; Reilly, Kathleen H; Neaigus, Alan; Braunstein, Sarah

    2017-06-29

    Women who inject drugs (WWID) are at heightened risk for HIV due to biological, behavioral, and structural factors. Pre-exposure prophylaxis (PrEP) could aid in HIV prevention for WWID. However, little is known about WWID awareness of PrEP, which is a necessary step that must occur before PrEP uptake. We report factors associated with greater awareness among WWID to identify efficient means of awareness dissemination. Data from the 2015 National HIV Behavioral Surveillance (NHBS) system cycle on injection drug use collected in New York City (NYC) were used. Bivariable analyses, using chi-squared statistics, were conducted to examine correlates of awareness of PrEP with socio-demographic, behavioral, and health care variables. Multivariable logistic regression was used to estimate adjusted associations and determine differences in awareness of PrEP. The analysis consisted of 118 WWID. Awareness of PrEP was relatively low (31%), and risk factors were high. In the last 12 months, almost two thirds (65%) reported condomless sex, approximately one third (31%) reported transactional sex, and one third (32%) reported sharing injection equipment. In multivariable logistic regression, increased PrEP awareness was associated with reported transactional sex (AOR 3.32, 95% CI 1.22-9.00) and having a conversation about HIV prevention at a syringe exchange program (SEP) (AOR 7.61, 95% CI 2.65-21.84). We did not find race, education, household income, age, binge drinking, or sexual identity to be significantly associated with PrEP awareness. Large proportions of WWID were unaware of PrEP. These findings suggest that social networks (specifically sex work and SEP networks) are an efficient means for disseminating messaging about prevention materials such as PrEP. We recommend that SEP access increase, SEP processes be adopted in other health care settings, and WWID networks be utilized to increase PrEP awareness.

  11. A successful strategy for estimating the consumption of needles and syringes by injecting drug users in the Czech Republic.

    PubMed

    Gabrhelík, Roman; Vacek, Jaroslav; Mista, Jan

    2014-01-01

    The objectives were to: (i) estimate the extent of the injecting equipment (IE) provided by needle exchange programs (NEPs) to injecting drug users (IDUs) in the Czech Republic in 2010; (ii) subsequently validate the recent methodology used for data collection by the Czech National Monitoring Centre for Drugs and Drug Addiction (CMC), and (iii) estimate the number of syringes provided to Czech IDUs. A simple document analysis was performed in order to collect data on the production, sale, and consumption of injecting equipment in the Czech Republic in combination with questionnaire screening in the NEPs and 21 brief interviews with key informants. Ten types of IE most commonly used for drug injecting by the Czech drug users were identified. Approximately 5,038,000 pieces of sterile IE were marketed in the Czech Republic in 2010. According to four manufacturers (with a market share of 96%) and with reference to the year 2010, 5,430,694 pieces of sterile IE were provided to Czech injecting drug users (487,694 pieces of IE were sold to IDUs in pharmacies and 5,038,000 pieces of IE were distributed by NEPs in 2010). We compared the amount of IE provided to IDUs as reported to the CMC National registry by NEPs (4,943,000) with that of IE distributed by manufacturers and distributors (5,038,000) in the country in 2010 and found a difference of less than two percent using two different methodologies. This study confirms the accuracy of the data on the amount of IE exchanged as collected by the CMC monitoring system. This study opens up important public health practice and policy-making issues. The methodology of this study may be used in regions where no data collection system is present or where confirmation of the data related to IE is needed.

  12. Factors associated with HIV testing among male injecting drug users: findings from a cross-sectional behavioural and biological survey in Manipur and Nagaland, India.

    PubMed

    Ganju, Deepika; Ramesh, Sowmya; Saggurti, Niranjan

    2016-06-21

    Although targeted interventions in India require all high-risk groups, including injecting drug users (IDUs), to test for HIV every 6 months, testing uptake among IDUs remains far from universal. Our study estimates the proportion of IDUs who have taken an HIV test and identifies the factors associated with HIV testing uptake in Nagaland and Manipur, two high HIV prevalence states in India where the epidemic is driven by injecting drug use. Data are drawn from the cross-sectional Integrated Behavioural and Biological Assessment (2009) of 1650 male IDUs from two districts each of Manipur and Nagaland. Participants were recruited using respondent-driven sampling (RDS). Descriptive data were analysed using RDSAT 7.1. Multivariate logistic regression analysis was undertaken using STATA 11 to examine the association between HIV testing and socio-demographic, behavioural and programme exposure variables. One third of IDUs reported prior HIV testing, of whom 8 % had tested HIV-positive. Among those without prior testing, 6.2 % tested HIV-positive in the current survey. IDUs aged 25-34 years (adjusted odds ratio (OR) = 1.41; 95 % confidence interval (CI) = 1.03-1.93), married (Adjusted OR = 1.56; 95 % CI = 1.15-2.12), had a paid sexual partner (Adjusted OR = 1.64; 95 % CI = 1.24-2.18), injected drugs for more than 36 months (Adjusted OR = 1.38; 95 % CI = 1.06-1.81), injected frequently (Adjusted OR = 1.49; 95 % CI = 1.12-1.98) and had high-risk perception (Adjusted OR = 1.68; 95 % CI = 1.32-2.14) were more likely than others to test for HIV. Compared to those with no programme exposure, IDUs who received counselling, or counselling and needle/syringe services, were more likely to test for HIV. HIV testing uptake among IDUs is low in Manipur and Nagaland, and a critical group of HIV-positive IDUs who have never tested for HIV are being missed by current programmes. This study identifies key sub-groups-including early initiators, short duration and less frequent injectors, perceived to be at low risk-for promoting HIV testing. Providing needles/syringes alone is not adequate to increase HIV testing; additionally, interventions must provide counselling services to inform all IDUs about HIV testing benefits, facilitate visits to testing centres and link those testing positive to timely treatment and care.

  13. Injecting drug users' experiences of policing practices in two Mexican-U.S. border cities: public health perspectives.

    PubMed

    Miller, Cari L; Firestone, Michelle; Ramos, Rebeca; Burris, Scott; Ramos, Maria Elena; Case, Patricia; Brouwer, Kimberly C; Fraga, Miguel Angel; Strathdee, Steffanie A

    2008-08-01

    Previous research has identified the impact of law enforcement practices on the behaviours and health of injection drug users (IDUs). We undertook a qualitative study of IDUs' experiences of policing practices in two Mexican cities on the U.S. border. In 2004, two teams of Mexican interviewers conducted in-depth interviews with IDUs residing in Tijuana and Ciudad Juarez (Cd. Juarez), Mexico, who had injected drugs at least once in the prior month. Topics included types of drug used, injection settings, access to sterile needles and experiences with police. Field notes and transcribed interviews were analysed to identify emergent themes. Amongst the 43 participants, most reported that it is common for IDUs to be arrested and detained for 36h for carrying sterile or used syringes. Most reported that they or someone they knew had been beaten by police. Interviews suggested five key themes relating to police influence on the risk environment: (1) impact of policing practices on accessibility of sterile syringes, (2) influence of police on choice of places to inject drugs (e.g., shooting galleries), (3) police violence, (4) police corruption and (5) perceived changes in policing practices. Findings suggest that some behaviour of police officers in Tijuana and Cd. Juarez is inconsistent with legal norms and may be negatively influencing the risk of acquiring blood-borne infections amongst IDUs. Implementing a comprehensive and successful HIV prevention programme amongst IDUs requires interventions to influence the knowledge, attitudes and practices of law enforcement officers.

  14. The pneumatic syringe: a simple apparatus for self-administration of drugs by rats.

    PubMed

    Weeks, J R

    1977-12-01

    Drug solution is delivered by a syringe operated by a pneumatic cylinder. Recommended delivery volumes are from 10 to 200 microliter. A solid-state control unit is described which can operate two syringes (drug injection and flush), has outputs for recording responses and injections, and can be programmed to provide several schedules of reinforcement. All components are readily commercially available.

  15. The effect of on-site and outreach-based needle and syringe programs in people who inject drugs in Kermanshah, Iran.

    PubMed

    Nazari, Seyed Saeed Hashemi; Noroozi, Mehdi; Soori, Hamid; Noroozi, Alireza; Mehrabi, Yadollah; Hajebi, Ahmad; Sharifi, Hamid; Higgs, Peter; Mirzazadeh, Ali

    2016-01-01

    Needle and syringe programs (NSPs) are widely used to reduce harms associated with drug injecting. This study assessed the effect of facility-based (on-site services at drop-in centre) and outreach models of NSP on injection risk behaviours. Self-reported data from 455 people who injected drugs (PWID) during 2014 in Kermanshah, Iran, were examined to measure demographic characteristics and risk behaviors. Self-reported and program data were also assessed to identify their main source of injection equipment. Participants were divided into three sub-groups: facility-based NSP users, outreach NSP users and non-users (comparison group). Coarsened exact matching was used to make the three groups statistically equivalent based on age, place of residence, education and income, and groups were compared regarding the proportion of borrowing or lending of syringes/cookers, reusing syringes and recent HIV testing. Overall, 76% of participants reported any NSP service use during the two months prior to interview. Only 23% (95%CI: 17-27) reported outreach NSP as their main source of syringes. Using facility-based NSP significantly decreased recent syringe borrowing (OR: 0.27, 95%CI: 0.10-0.70), recent syringe reuse (OR: 0.38, 95%CI: 0.23-0.68) and increased recent HIV testing (OR: 2.60, 95%CI: 1.48-4.56). Similar effects were observed among outreach NSP users; in addition, the outreach NSP model significantly reduced the chance of lending syringes (OR: 0.31, 95%CI: 0.15-0.60), compared to facility-based NSP (OR: 1.25, 95%CI: 0.74-2.17). These findings suggest that the outreach NSP model is as effective as facility-based NSP in reducing injection risk behaviours and increasing the rate of HIV testing. Outreach NSP was even more effective than facility-based in reducing the lending of syringes to others. Scaling up outreach NSP is an effective intervention to further reduce transmission of HIV via needle sharing. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Tumescent and syringe liposculpture: a logical partnership.

    PubMed

    Hunstad, J P

    1995-01-01

    Liposuction has been traditionally performed under general anesthesia. Standard instrumentation for the procedure has included blunt-tipped suction cannulae connected to an electric vacuum pump by noncollapsible tubing. A subcutaneous injection of Lidocaine with Epinephrine is routinely employed to minimize blood loss during the procedure. This infiltration has been described as the "wet technique," but it is not a method to supplant general anesthesia. The tumescent technique, a method of infusing very large volumes of dilute lidocaine with epinephrine solutions, has been advocated as a satisfactory means for providing conscious anesthesia for liposuction procedures, avoiding the need for general anesthesia. The syringe technique employs blunt-tipped suction cannulae connected to a syringe. Drawing back the syringe plunger generates the negative pressures needed to remove fat during liposuction and replaces the electric vacuum pump and connecting tubing traditionally used for this procedure. This study evaluates the combined tumescent and syringe techniques for liposuction. One hundred consecutive patients were treated with the tumescent technique as the sole means of anesthesia and the syringe technique as the sole means of performing liposuction. A modified tumescent formula is presented. A comparison of liposuction aspirates using this modified tumescent technique is compared and contrasted to liposuction aspirates obtained using the "dry technique" and the "wet technique." A historical review of the syringe technique and its perceived attributes is also presented. Technical descriptions of the tumescent infusion method, tumescent fluid formulation, and suggested patient sedation and monitoring is presented. Photographic documentation of patients who underwent the combined tumescent and syringe liposculpture treating various body areas is shown. A critical analysis of the limitations of this combined technique is also described noting added time requirements, difficulties with under-correction of deformities, and need for reoperation, methods for determining the "end-point" for the procedure, as well as addressing large-volume liposuction problems. The conclusion reached by this study is that combining the tumescent technique and the syringe technique is a logical partnership. Each method complements the other, allowing liposuction to be performed with considerable advantage over traditional methods. These advantages include eliminating the need for general anesthesia, lessening blood loss and postoperative bruising, greater accuracy, precision, and overall high patient satisfaction.

  17. Adsorption of 99mTc-sestamibi onto plastic syringes: evaluation of factors affecting the degree of adsorption and their impact on clinical studies.

    PubMed

    Swanson, Tiffinee N; Troung, Duong T; Paulsen, Andrew; Hruska, Carrie B; O'Connor, Michael K

    2013-12-01

    The purpose of this study was to document the extent of adhesion of (99m)Tc-sestamibi to syringes in patient procedures, determine factors that influence the degree of adhesion, and evaluate alternatives to our current practice that would either result in a more reproducible degree of adhesion or, ideally, eliminate adhesion. The extent of adhesion was documented in 216 patient procedures and evaluated in detail in an additional 73 patient procedures. We evaluated the nature of the adhesion and its possible causes, including the location of adhesion in injection sets, the effect of syringe type, and the effect of prerinsing of syringes with various solutions of nonradiolabeled sestamibi and (99m)Tc-sestamibi. The extent of adhesion was reevaluated in 50 procedures performed using the syringe type that demonstrated the lowest adhesion rate. The degree of adhesion of (99m)Tc-sestamibi to the injection set was found to be 20.1% ± 8.0%, with a range (10th-90th percentiles) of 9%-31%. The primary cause of adhesion appeared to be the lubricant used inside the syringe barrel. Evaluation of 6 different syringe types identified a brand with a lower adhesion rate. Reevaluation in patient procedures using this brand showed a 5.2% ± 2.5% degree of adhesion, with a range (10th-90th percentiles) of 2.5%-7.7%. Selection of the appropriate type of syringe can significantly reduce the magnitude and variability of residual (99m)Tc-sestamibi activity. With more reproducible residual activities, we have been able to achieve an approximately 20% reduction in the dispensed dose of (99m)Tc-sestamibi used in clinical procedures and a more consistent injected dose with less interpatient variation. The frequent changes in syringe design by manufacturers require that a quality control program for monitoring of residual activity be incorporated into clinical practice. This program has allowed us to maintain image quality and achieve more consistent injected patient doses in clinical procedures that use (99m)Tc-sestamibi.

  18. XVII International AIDS Conference: From Evidence to Action - Regional focus

    PubMed Central

    2009-01-01

    This article summarizes the challenges, opportunities and lessons learned from presentations, discussions and debates addressing major policy and programmatic responses to HIV in six geographical regions: Sub-Saharan Africa, Asia and the Pacific, Eastern Europe and Central Asia, Latin America, Caribbean, and Middle East and North Africa. It draws from AIDS 2008 Leadership and Community Programmes, particularly the six regional sessions, and Global Village activities. While the epidemiological, cultural and socio-economic contexts in these regions vary considerably, several common, overarching principles and themes emerged. They include: advancing basic human rights, particularly for vulnerable and most at risk populations; ensuring the sustainability of the HIV response through long-term, predictable financing; strengthening health systems; investing in strategic health information; and improving accountability and the involvement of civil society in the response to AIDS. Equally important is the need to address political barriers to implementing evidence-based interventions such as opioid substitution therapy (OST), needle and syringe programmes (NSPs), comprehensive sexuality education for youth, and sexual and reproductive rights. Finally, these regional discussions emphasized the need for legislative and policy reforms related to structural barriers facing women and girls, MSM, IDUs, sex workers and migrant populations. PMID:19811672

  19. Undoing the Knots: Identity Transformations in a Study Abroad Programme

    ERIC Educational Resources Information Center

    Ellwood, Constance

    2011-01-01

    In times of globalised flows of students, this paper offers an alternative way of conceptualising identity change in the experiences of students on study abroad or student exchange programmes. Despite the "identity turn" of recent years, modernist notions of identity continue to impact on the ways in which study abroad experiences are…

  20. A Longitudinal Study of Teachers' Professional Development through an International Exchange

    ERIC Educational Resources Information Center

    Purves, Ross; Jackson, Anita; Shaughnessy, Julie

    2005-01-01

    The Teachers' International Professional Development (TIPD) Programme was launched by the British Council in 2000 in response to a Government Green Paper on teacher training. This provides opportunities for teachers to participate in international study visits to gain first-hand experience of good practice. As part of this programme, eighteen…

  1. Do Students Share the Same Experience in an Online Language Exchange Programme?--The Chinese-French eTandem Case

    ERIC Educational Resources Information Center

    Szilas, Jue Wang; Zhang, Ling; Berger, Claudia

    2013-01-01

    This article presents the findings of an eTandem Chinese-French exchange course during two academic years, the year 2010-2011 when the course was not credited, and the year 2011-2012 when the course was credited in one university but not in the other. It focuses on the students' perspective about the language exchange experience. The participants…

  2. Elimination of HCV as a public health concern among people who inject drugs by 2030 - What will it take to get there?

    PubMed

    Grebely, Jason; Dore, Gregory J; Morin, Sébastien; Rockstroh, Jürgen K; Klein, Marina B

    2017-07-28

    Globally, there is a considerable burden of HCV and HIV infections among people who inject drugs (PWID) and transmission of both infections continues. Needle and syringe programme (NSP) and opioid substitution therapy (OST) coverage remains low, despite evidence demonstrating their prevention benefit. Direct-acting antiviral therapies (DAA) with HCV cure >95% among PWID provide an opportunity to reverse rising trends in HCV-related morbidity and mortality and reduce incidence. However, HCV testing, linkage to care, and treatment remain low due to health system, provider, societal, and patient barriers. Between 2015 and 2030, WHO targets include reducing new HCV infections by 80% and HCV deaths by 65%, and increasing HCV diagnoses from <5% to 90% and number of eligible persons receiving HCV treatment from <1% to 80%. This commentary discusses why PWID should be considered as a priority population in these efforts, reasons why this goal could be attainable among PWID, challenges that need to be overcome, and key recommendations for action. Challenges to HCV elimination as a global health concern among PWID include poor global coverage of harm reduction services, restrictive drug policies and criminalization of drug use, poor access to health services, low HCV testing, linkage to care and treatment, restrictions for accessing DAA therapy, and the lack of national strategies and government investment to support WHO elimination goals. Key recommendations for action include reforming drug policies (decriminalization of drug use and/or possession, or providing alternatives to imprisonment for PWID; decriminalization of the use and provision of sterile needles-syringes; and legalization of OST for people who are opioid dependent), scaling up and improving funding for harm reduction services, making health services accessible for PWID, supporting community empowerment and community-based programmes, improving access to affordable diagnostics and medicines, and eliminating stigma, discrimination, and violence against PWID. The ambitious targets for HCV elimination set by WHO are achievable in many countries, but will require researchers, healthcare providers, policy makers, affected communities, advocates, the pharmaceutical and diagnostics industries, and governments around the world to work together to make this happen.

  3. Elimination of HCV as a public health concern among people who inject drugs by 2030 – What will it take to get there?

    PubMed Central

    Grebely, Jason; Dore, Gregory J.; Morin, Sébastien; Rockstroh, Jürgen K.; Klein, Marina B.

    2017-01-01

    Abstract Introduction: Globally, there is a considerable burden of HCV and HIV infections among people who inject drugs (PWID) and transmission of both infections continues. Needle and syringe programme (NSP) and opioid substitution therapy (OST) coverage remains low, despite evidence demonstrating their prevention benefit. Direct-acting antiviral therapies (DAA) with HCV cure >95% among PWID provide an opportunity to reverse rising trends in HCV-related morbidity and mortality and reduce incidence. However, HCV testing, linkage to care, and treatment remain low due to health system, provider, societal, and patient barriers. Between 2015 and 2030, WHO targets include reducing new HCV infections by 80% and HCV deaths by 65%, and increasing HCV diagnoses from <5% to 90% and number of eligible persons receiving HCV treatment from <1% to 80%. This commentary discusses why PWID should be considered as a priority population in these efforts, reasons why this goal could be attainable among PWID, challenges that need to be overcome, and key recommendations for action. Discussion: Challenges to HCV elimination as a global health concern among PWID include poor global coverage of harm reduction services, restrictive drug policies and criminalization of drug use, poor access to health services, low HCV testing, linkage to care and treatment, restrictions for accessing DAA therapy, and the lack of national strategies and government investment to support WHO elimination goals. Key recommendations for action include reforming drug policies (decriminalization of drug use and/or possession, or providing alternatives to imprisonment for PWID; decriminalization of the use and provision of sterile needles-syringes; and legalization of OST for people who are opioid dependent), scaling up and improving funding for harm reduction services, making health services accessible for PWID, supporting community empowerment and community-based programmes, improving access to affordable diagnostics and medicines, and eliminating stigma, discrimination, and violence against PWID. Conclusions: The ambitious targets for HCV elimination set by WHO are achievable in many countries, but will require researchers, healthcare providers, policy makers, affected communities, advocates, the pharmaceutical and diagnostics industries, and governments around the world to work together to make this happen. PMID:28782335

  4. UMIST, IDN, NTUA, TUM, ULB: A Successful European Exchange Programme.

    ERIC Educational Resources Information Center

    Borne, Pierre; Singh, Madan G.

    1989-01-01

    Describes the exchange programs that existed for a decade in the fields of automatic control and computer science including the University of Manchester Institute of Science and Technology, the "Institut Industriel du Nord," the National Technical University of Athens, the Technical University of Munich, and the Free University of…

  5. Knowledge Exchange with Sistema Scotland

    ERIC Educational Resources Information Center

    Allan, Julie; Moran, Nikki; Duffy, Celia; Loening, Gica

    2010-01-01

    This paper reports on a knowledge exchange project, funded by the Scottish Funding Council and undertaken by a group of researchers from three higher education institutions in Scotland and the project partner, Sistema Scotland. This newly established charity is attempting to implement a major programme of social change, developed in Venezuela,…

  6. Tandem Translation Classroom: A Case Study

    ERIC Educational Resources Information Center

    Kim, Dohun; Koh, Taejin

    2018-01-01

    The transition to student-centred learning, advances in teleconferencing tools, and active international student exchange programmes have stimulated tandem learning in many parts of the world. This pedagogical model is based on a mutual language exchange between tandem partners, where each student is a native speaker in the language the…

  7. Novel dispersive micro-solid-phase extraction combined with ultrahigh-performance liquid chromatography-high-resolution mass spectrometry to determine morpholine residues in citrus and apples.

    PubMed

    Chen, Dawei; Miao, Hong; Zou, Jianhong; Cao, Pei; Ma, Ning; Zhao, Yunfeng; Wu, Yongning

    2015-01-21

    This paper presents a new analytical method for the determination of morpholine residues in citrus and apples using a novel dispersive micro-solid-phase extraction (DMSPE), followed by ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). Samples were extracted with 1% formic acid in acetonitrile/water (1:1, v/v) and then cleaned up using the DMSPE procedure. Morpholine from the extract was adsorbed to a polymer cation exchange sorbent and eluted with ammonium hydroxide/acetonitrile (3:97, v/v) through a 1 mL syringe with a 0.22 μm nylon syringe filter. All of the samples were analyzed by UHPLC-HRMS/MS on a Waters Acquity BEH hydrophilic interaction chromatography column using 0.1% formic acid and 4 mM ammonium formate in water/acetonitrile as the mobile phase with gradient elution. The method showed good linearity (R(2) > 0.999) in the range of 1-100 μg/L for the analyte. The limit of detection and limit of quantitation values of morpholine were 2 and 5 μg/kg, respectively. The average recoveries of morpholine from the citrus and apple samples spiked at three different concentrations (5, 20, and 100 μg/kg) were in a range from 78.4 to 102.7%.

  8. Cannula Implantation into the Cisterna Magna of Rodents.

    PubMed

    Xavier, Anna L R; Hauglund, Natalie Linea; von Holstein-Rathlou, Stephanie; Li, Qianliang; Sanggaard, Simon; Lou, Nanhong; Lundgaard, Iben; Nedergaard, Maiken

    2018-05-23

    Cisterna magna cannulation (CMc) is a straightforward procedure that enables direct access to the cerebrospinal fluid (CSF) without operative damage to the skull or the brain parenchyma. In anesthetized rodents, the exposure of the dura mater by blunt dissection of the neck muscles allows the insertion of a cannula into the cisterna magna (CM). The cannula, composed either by a fine beveled needle or borosilicate capillary, is attached via a polyethylene (PE) tube to a syringe. Using a syringe pump, molecules can then be injected at controlled rates directly into the CM, which is continuous with the subarachnoid space. From the subarachnoid space, we can trace CSF fluxes by convective flow into the perivascular space around penetrating arterioles, where solute exchange with the interstitial fluid (ISF) occurs. CMc can be performed for acute injections immediately following the surgery, or for chronic implantation, with later injection in anesthetized or awake, freely moving rodents. Quantitation of tracer distribution in the brain parenchyma can be performed by epifluorescence, 2-photon microscopy, and magnetic resonance imaging (MRI), depending on the physico-chemical properties of the injected molecules. Thus, CMc in conjunction with various imaging techniques offers a powerful tool for assessment of the glymphatic system and CSF dynamics and function. Furthermore, CMc can be utilized as a conduit for fast, brain-wide delivery of signaling molecules and metabolic substrates that could not otherwise cross the blood brain barrier (BBB).

  9. European Network of Trainees in Obstetrics and Gynaecology: experiences from the 2016 exchange programme in Turin, Italy.

    PubMed

    Eismann, Sabine; Brandl, Mario; Spinnewijn, Laura; Everden, Caroline; Campolo, Federica; Schott, Sarah

    2017-02-01

    The European Network of Trainees in Obstetrics and Gynaecology (ENTOG) is an organization representing trainees from 30 European member countries. Together with the European Board and College of Obstetrics and Gynaecology (EBCOG), it seeks to achieve the highest possible standards of training and consequently to improve the quality of medical care in the field of gynaecology and obstetrics. Every year, the ENTOG council meets and holds a scientific meeting in a different European country. To coincide with this, the host country arranges an exchange, to which each member country can send two trainees. This exchange allows trainees to gain insight into both daily clinical work and the structure of the health care system. This article reports the experiences of participants in the May 2016 ENTOG exchange to Turin, Italy. The aim is to outline differences in training between Germany and Italy as well as some striking differences with other European countries. The participants' personal benefit from this unique experience was not only to get familiar with the Italian trainee programme and health care system, but also to exchange experiences among representatives from other European countries and build up a young gynaecological network within Europe.

  10. Comparison of different obturation techniques for primary molars by digital radiography.

    PubMed

    Memarpour, Mahtab; Shahidi, Shoaleh; Meshki, Razieh

    2013-01-01

    The purpose of this study was to compare six methods of root canal filling in primary mandibular second molars via digital radiography. A total of 239 canals were prepared and obturated with zinc-oxide eugenol paste. Obturation methods compared were: anesthetic syringe; NaviTip syringe; pressure syringe; tuberculin syringe; lentulo spiral; and packing with a plugger. The canals were evaluated in photostimulated phosphor radiographs for length of obturation, presence of voids, and number and sum of void sizes. The data were analyzed using chi-square, Kruskal-Wallis and Mann-Whitney tests. There were significant differences between all groups in the length of obturation (P>.01) and presence of voids (P<.001). The lentulo and tuberculin syringe groups, respectively, showed the best and worst results for length of obturation. Significant differences were also found in the number of voids (P<.001) and mean sum of void sizes in the coronal (P<.001) and middle third (P=.003). For the number and size of the voids, the NaviTip group showed the best results. Lentulo produced the best results in terms of length of obturation, while NaviTip syringe produced the best results in controlling paste extrusion from the apical foramen and having the smallest void size and lowest number of voids.

  11. A syringe-sharing model for the spread of HIV: application to Omsk, Western Siberia.

    PubMed

    Artzrouni, Marc; Leonenko, Vasiliy N; Mara, Thierry A

    2017-03-01

    A system of two differential equations is used to model the transmission dynamics of human immunodeficiency virus between 'persons who inject drugs' (PWIDs) and their syringes. Our vector-borne disease model hinges on a metaphorical urn from which PWIDs draw syringes at random which may or may not be infected and may or may not result in one of the two agents becoming infected. The model's parameters are estimated with data mostly from the city of Omsk in Western Siberia. A linear trend in PWID prevalence in Omsk could only be fitted by considering a time-dependent version of the model captured through a secular decrease in the probability that PWIDs decide to share a syringe. A global sensitivity analysis is performed with 14 parameters considered random variables in order to assess their impact on average numbers infected over a 50-year projection. With obvious intervention implications the drug injection rate and the probability of syringe-cleansing are the only parameters whose coefficients of correlations with numbers of infected PWIDs and infected syringes have an absolute value close to or larger than 0.40. © The authors 2015. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  12. The evaluation of a trial of syringe vending machines in Canberra, Australia.

    PubMed

    McDonald, David

    2009-07-01

    Syringe vending machines (SVMs) have been trialled in Canberra, Australian Capital Territory, Australia, as an intervention aiming to increase the availability of sterile injecting equipment for use by IDUs. This study evaluated the 12-month trial. A utilisation-focused evaluation model, with both formative and summative components, was employed. Four SVMs were installed, each dispensing packs containing four 1 mL syringes and associated injecting paraphernalia. The trial participants were the clients of the SVMs and other key informants. The core measurements used were the number of syringes dispensed in Canberra by SVMs and other outlets, SVM clients' demographics and experiences of and attitudes towards SVMs, perceived impacts of SVMs on needle sharing, unsafe disposal of used syringes in the vicinity of SVMs, and community and stakeholder attitudes. The trial was implemented successfully, with no adverse consequences identified. The SVMs appear to be serving both the usual clients of the other outlets for sterile injecting equipment (community pharmacies and the Needle Syringe Program outlets) and others who are reluctant to use such outlets or find them inconvenient. The out-of-business-hours provision of syringes through the SVMs was particularly welcomed by both SVM clients and other stakeholders. The continuing operation of the initial four SVMs is widely supported, and additional machines are requested by clients and others. Owing to the success of the trial in terms of feasibility and outcomes for both IDUs and for the broader community, it is desirable that providing sterile injecting equipment through SVMs continues and be expanded as an integral component of harm reduction strategies.

  13. Don't Throw Away Syringes!

    ERIC Educational Resources Information Center

    John, E.

    1975-01-01

    Describes a variety of laboratory experiments including carbon dioxide reduction, animal respiration, atmospheric pressure determination, and others, that can be performed using discarded syringes. (GS)

  14. The impact of harm reduction programs and police interventions on the number of syringes collected from public spaces. A time series analysis in Barcelona, 2004-2014.

    PubMed

    Espelt, A; Villalbí, J R; Bosque-Prous, M; Parés-Badell, O; Mari-Dell'Olmo, M; Brugal, M T

    2017-12-01

    To estimate the effect of opening two services for people who use drugs and three police interventions on the number of discarded syringes collected from public spaces in Barcelona between 2004 and 2014. We conducted an interrupted time-series analysis of the monthly number of syringes collected from public spaces during this period. The dependent variable was the number of syringes collected per month. The main independent variables were month and five dummy variables (the opening of two facilities with safe consumption rooms, and three police interventions). To examine which interventions affected the number of syringes collected, we performed an interrupted time-series analysis using a quasi-Poisson regression model, obtaining relative risks (RR) and 95% confidence intervals (CIs). The number of syringes collected per month in Barcelona decreased from 13,800 in 2004 to 1655 in 2014 after several interventions. For example, following the closure of an open drug scene in District A of the city, we observed a decreasing trend in the number of syringes collected [RR=0.88 (95% CI: 0.82-0.95)], but an increasing trend in the remaining districts [RR=1.11 (95% CI: 1.05-1.17) and 1.08 (95% CI: 0.99-1.18) for districts B and C, respectively]. Following the opening of a harm reduction facility in District C, we observed an initial increase in the number collected in this district [RR=2.72 (95% CI: 1.57-4.71)] and stabilization of the trend thereafter [RR=0.97 (95% CI: 0.91-1.03)]. The overall number of discarded syringes collected from public spaces has decreased consistently in parallel with a combination of police interventions and the opening of harm reduction facilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A cross-sectional study of the feasibility of pharmacy-delivered harm reduction services among people who inject drugs in Xichang, China.

    PubMed

    Yang, Yi; Latkin, Carl A; Luan, Rongsheng; Yang, Cui

    2015-09-14

    HIV prevalence is high in Liangshan, China (1.1 %). In 2012, people who inject drugs (PWID) in Xichang, the capital city, contributed to 60.0 % of the HIV infections. The goal of the current study was to examine the feasibility of implementing pharmacy-delivered harm reduction services (PDHRS) for PWID. Face-to-face structured interviews with 403 PWID included questions on PWID's experiences of syringe services and their specific experiences, acceptance, and potential usage of PDHRS. There were some reports of harassment/bad treatment from pharmacists (12.2 %) and police (17.6 %). Non-prescription syringe sales (NPSS) from pharmacies in single piece were the main source (82.1 %) of syringes. 72.5 % of PWID reported visiting 31.5 % of the identified pharmacies. Most (74.7 %) PWID disposed of their used syringes by throwing them away. Only one PWID brought used syringes back to a pharmacy in the past 30 days. Half of the PDHRS, such as printed materials about HIV, Hepatitis C and STIs; risk reduction services; (16.9 %) and sharps container to dispose of syringes (0.2 %) were offered by a few pharmacies (<20 % for each service). The acceptance rates among PWID toward currently offered services were high (≥91.1 %). All potential PDHRS were acceptable by most (68-95.3 %) PWID, and correspondingly 67-94.5 % of PWID reported they would use each service if offered. NPSS from pharmacies provided many PWID in Liangshan with new syringes. However, disposal of used syringes was problematic. At the time of investigation, half of 16 assessed PDHRS were already available in pharmacies in Xichang. PWID were ready to use all the potential PDHRS and14 of 16 PDHRS were feasible to provide. HIV testing kits may be available in pharmacies in the future. Many pharmacy-delivered harm reduction services are feasible and acceptable among PWID in Xichang, China.

  16. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    PubMed

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.

  17. New Processes for Freeze-Drying in Dual-Chamber Systems.

    PubMed

    Werk, T; Ludwig, I S; Luemkemann, J; Huwyler, J; Mahler, H-C; Haeuser, C R; Hafner, M

    2016-01-01

    Dual-chamber systems can offer self-administration and home care use for lyophilized biologics. Only a few products have been launched in dual-chamber systems so far-presumably due to dual-chamber systems' complex and costly drug product manufacturing process. Within this paper, two improved processes (both based on tray filling technology) for freeze-drying pharmaceuticals in dual-chamber systems are described. Challenges with regards to heat transfer were tackled by (1) performing the freeze-drying step in a needle-down orientation in combination with an aluminum block, or (2) freeze-drying the drug product "externally" in a metal cartridge with subsequent filling of the lyophilized cake into the dual-chamber system. Metal-mediated heat transfer was shown to be efficient in both cases and batch (unit-to-unit) homogeneity with regards to sublimation rate was increased. It was difficult to influence ice crystal size using different methods when in use with an aluminum block due to its heat capacity. Using such a metal carrier implies a large heat capacity leading to relatively small ice crystals. Compared to the established process, drying times were reduced by half using the new processes. The drying time was, however, longer for syringes compared to vials due to the syringe design (long and slim). The differences in drying times were less pronounced for aggressive drying cycles. The proposed processes may help to considerably decrease investment costs into dual-chamber system fill-finish equipment. Dual-chamber syringes offer self-administration and home care use for freeze-dried pharmaceuticals. Only a few products have been launched in dual-chamber syringes so far-presumably due to their complex and costly drug product manufacturing process. In this paper two improved processes for freeze-drying pharmaceuticals in dual-chamber syringes are described. The major challenge of freeze-drying is to transfer heat through a vacuum. The proposed processes cope with this challenge by (1) freeze-drying the drug product in the syringe in an orientation in which the product is closest to the heat source, or (2) freeze-drying the drug product outside the syringe in a metal tube. The latter requires filling the freeze-dried product subsequently into the dual-chamber syringe. Both processes were very efficient and promised to achieve similar freeze-drying conditions for all dual-chamber syringes within one production run. The proposed processes may help to considerably decrease investment costs into dual-chamber syringe fill-finish equipment. © PDA, Inc. 2016.

  18. A strategy for the prevention of protein oxidation by drug product in polymer-based syringes.

    PubMed

    Nakamura, Koji; Abe, Yoshihiko; Kiminami, Hideaki; Yamashita, Arisa; Iwasaki, Kazuhiro; Suzuki, Shigeru; Yoshino, Keisuke; Dierick, William; Constable, Kevin

    2015-01-01

    Recently, new and advanced ideas have been presented on the value of polymer-based syringes for improved safety, better strength, reduced aggregation, and the prevention of drug degradation. In this report, our findings on drug degradation from protein oxidation will be presented and discussed. Commonly, dissolved oxygen is one of the factors for causing protein degradation. Due to the nature of higher gas permeability in polymer-based syringes, it was thought to be difficult to control the oxygen level during storage. However, this report demonstrates the appropriateness of combining the use of an oxygen absorber within the secondary packaging as a deoxygenated packaging system. In addition, this report suggests that another factor to enhance protein oxidization is related to radicals on the syringe barrel from sterilization by irradiation. We demonstrate that steam sterilization can minimize protein oxidization, as the protein filled in steam sterilized syringe is much more stable. In conclusion, the main oxidation pathway of a protein has been identified as dissolved oxygen and radical generation within a polymer container. Possible solutions are herewith presented for controlling oxidation by means of applying a deoxygenated packaging system as well as utilizing steam sterilization as a method of sterilization for prefillable polymer syringes. There have been many presentations and discussions about the risks associated with glass prefilled syringes. Advanced ideas are being presented on the value of polymer-based syringes for improved safety, better strength, reduced protein aggregation, and the prevention of drug degradation. Drug degradation based on protein oxidation is discussed in this report. Identification of the main factors causing this degradation and possible solutions available by using polymer-based syringes will be presented. The causes of protein oxidation have been identified as dissolved oxygen and radicals generated by the applied method of sterilization. The oxidation reaction created by dissolved oxygen within the drug product can be effectively inhibited by controlling the removal of the oxygen through the use of a deoxygenated packaging system. This packaging system can control the level or complete removal of oxygen from the primary container and the secondary packaging system. Protein oxidation induced by the formation of radicals from sterilization by irradiation is another critical aspect where it was thought that various sterilization methods were acceptable without loosing drug product quality. However, this report is first to demonstrate that gamma sterilized polymer-based syringes accelerated protein oxidation by radical generation; this effect can be prevented by means of steam sterilization. © PDA, Inc. 2015.

  19. Does a simple syringe applicator enhance bone cement set up time in knee arthroplasty?

    PubMed Central

    Sodhi, Nipun; Dalton, Sarah E.; Khlopas, Anton; Sultan, Assem A.; Curtis, Gannon L.; Harb, Matthew A.; Naziri, Qais; Barrington, John W.; Mont, Michael A.

    2017-01-01

    Background The time required for polymethylmethacrylate (PMMA) cement curing or hardening can be modified by a number of variables including the mixing technique, and the temperature and pressure at which the process is taking place. Therefore, the purpose of this study was to evaluate two different methods of PMMA application in terms of set up time. Specifically, we (I) compared the PMMA set up time of cement that remained in the mixing bowl to cement that was placed in a syringe and (II) extrapolated the associated annual cost difference on the national and individual surgeon levels. Methods The cement set up time was measured for a total of 146 consecutive patients who underwent either unicompartmental knee arthroplasty (n=136) or patellofemoral arthroplasty (n=10) between January 2016 and April 2017. One pack of PMMA powder and monomer were mixed, placed in a 300 mL small plastic bowl, and mixed with a tongue depressor. Then, 50 mL of the mixed PMMA was placed in a sterile 60 mL syringe with the tip cut to a 6-mm opening, and the syringe was used to apply the cement to the bone and the prosthesis surface. The remaining unused cement in the syringe (syringe group) and the remaining unused cement in the plastic bowl (bowl group) were removed and formed into a two separate 2 cm diameter cubes that were allowed to cure at room temperature on a sterile set of osteotomes. The two cubes of cement were timed for complete PMMA curing. A two-tailed student’s t-test was used to compare the curing time for the two groups. Annual cost differences were calculated on the national and individual surgeon level. The total number of daily cases performed and the operative time savings using the syringe applicator was used to find daily and annual cost savings. Results The mean time for the cement to set up in the bowl group was 16.8±2.1 minutes, and the mean time for cement set up in the syringe group was 15.1±1.7 minutes. Compared to the bowl group cement set up time, the syringe group set up time was significantly lower (P<0.0001). An estimated 350,000 cemented knee arthroplasties are performed each year in the United States. With 1.7 minutes saved per case, 595,000 operating room minutes per year could be saved, resulting in a nearly $71,000,000 national and $110,000 individual surgeon annual cost savings. Conclusions The results of the present study demonstrated that the utilization of a simple, inexpensive syringe applicator enhanced the cement set up time by over one and a half minutes. This may be a result of the pressure differences in the syringe applicator. In addition to the control of and precision of where the cement is placed, the syringe applicator could provide an important potential time advantage to the arthroplasty surgeon. PMID:29299472

  20. High-throughput optofluidic system for the laser microsurgery of oocytes

    NASA Astrophysics Data System (ADS)

    Chandsawangbhuwana, Charlie; Shi, Linda Z.; Zhu, Qingyuan; Alliegro, Mark C.; Berns, Michael W.

    2012-01-01

    This study combines microfluidics with optical microablation in a microscopy system that allows for high-throughput manipulation of oocytes, automated media exchange, and long-term oocyte observation. The microfluidic component of the system transports oocytes from an inlet port into multiple flow channels. Within each channel, oocytes are confined against a microfluidic barrier using a steady fluid flow provided by an external computer-controlled syringe pump. This allows for easy media replacement without disturbing the oocyte location. The microfluidic and optical-laser microbeam ablation capabilities of the system were validated using surf clam (Spisula solidissima) oocytes that were immobilized in order to permit ablation of the 5 μm diameter nucleolinus within the oocyte nucleolus. Oocytes were the followed and assayed for polar body ejection.

  1. The use of arithmetic average method in identifying critical success criteria for Homestay Programmes

    NASA Astrophysics Data System (ADS)

    Daud, Shahidah Md; Ramli, Razamin; Kasim, Maznah Mat; Kayat, Kalsom; Razak, Rafidah Abd

    2015-12-01

    Malaysian Homestay is very unique. It is classified as Community Based Tourism (CBT). Homestay Programme which is a community events where a tourist stays together with a host family for a period of time and enjoying cultural exchange besides having new experiences. Homestay programme has booming the tourism industry since there is over 100 Homestay Programme currently being registered with the Ministry of Culture and Tourism Malaysia. However, only few Homestay Programme enjoying the benefits of success Homestay Programme. Hence, this article seeks to identify the critical success factors for a Homestay Programme in Malaysia. An Arithmetic Average method is utilized to further evaluate the identified success factors in a more meaningful way. The findings will help Homestay Programme function as a community development tool that manages tourism resources. Thus, help the community in improving local economy and creating job opportunities.

  2. Microgravity

    NASA Image and Video Library

    1994-02-16

    These Vapor Diffusion Apparatus (VDA) trays were first flown in the Thermal Enclosure System (TES) during the USMP-2 (STS-62) mission. Each tray can hold 20 protein crystal growth chambers. Each chamber contains a double-barrel syringe; one barrel holds protein crystal solution and the other holds precipitant agent solution. During the microgravity mission, a torque device is used to simultaneously retract the plugs in all 20 syringes. The two solutions in each chamber are then mixed. After mixing, droplets of the combined solutions are moved onto the syringe tips so vapor diffusion can begin. During the length of the mission, protein crystals are grown in the droplets. Shortly before the Shuttle's return to Earth, the experiment is deactivated by retracting the droplets containing protein crystals, back into the syringes.

  3. Measurement of intraosseous pressures generated by the Wand, high-pressure periodontal ligament syringe, and the Stabident system.

    PubMed

    Shepherd, P A; Eleazer, P D; Clark, S J; Scheetz, J P

    2001-06-01

    Intraosseous pressure generated by the use of three anesthetic systems-the Wand; a hand-operated high-pressure periodontal ligament (PDL) syringe; and the Stabident system-were studied in fresh mandibles of 14 large swine. The mandibles were drilled and tapped in one area of both the right and left posterior molar regions. Pressure gauges were attached via threaded fittings. Pressures during injection were recorded for the Wand first, then the PDL syringe, and finally Stabident. Results showed averages of 8.3 mm Hg generated by the Wand, 16.3 mm Hg with the high-pressure PDL syringe, and 43.7 mm Hg from the Stabident system. Results were corroborated with data from three human cadaver mandibles.

  4. Macromolecular crystal growing system

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S. (Inventor); Herren, Blair J. (Inventor); Carter, Daniel C. (Inventor); Yost, Vaughn H. (Inventor); Bugg, Charles E. (Inventor); Delucas, Lawrence J. (Inventor); Suddath, Fred L. (Inventor)

    1991-01-01

    A macromolecular crystal growing system especially designed for growing crystals in the low gravity of space as well as the gravity of earth includes at least one tray assembly, a carrier assembly which receives the tray, and a refrigeration-incubation module in which the carrier assembly is received. The tray assembly includes a plurality of sealed chambers with a plastic syringe and a plug means for the double tip of the syringe provided therein. Ganging mechanisms operate the syringes and plugs simultaneously in a precise and smooth operation. Preferably, the tray assemblies are mounted on ball bearing slides for smooth operation in inserting and removing the tray assemblies into the carrier assembly. The plugging mechanism also includes a loading control mechanism. A mechanism for leaving a syringe unplugged is also provided.

  5. International community health networking project: two year follow-up of graduates.

    PubMed

    Duffy, M E; Farmer, S; Ravert, P; Huittinen, L

    2005-03-01

    This paper presents the perceptions of graduates 2 years post-exchange in a USA-European Union funded programme. The primary goal of this 8-week exchange programme was to increase cultural knowledge and sensitivity by teaching a common module of community health assessment and planning to multi-national groups of undergraduate students in four countries. Cultural diversity and globalization are among the factors that encourage faculty in nursing to develop programmes of international exchange for students. The challenge is to combine the exchange with the teaching of other courses required by the home institution during the same semester. Twenty-one graduates of participating USA schools responded to an open-ended interview by telephone or email 2 years after graduation. Bennett's continuum (1993) of intercultural sensitivity was used to assess cultural development. Graduates overwhelmingly supported international education and described its continued impact personally and professionally. Gains in cultural sensitivity were perceived as the greatest benefit and influence on their practice. The majority of graduates were believed to be in Bennett's ethnorelative categories of acceptance and adaptation. The depth and breadth of previous cultural experiences, specific host and home schools, and previous travel were found to be related to development on the intercultural sensitivity continuum. Most important are the findings from this evaluation that provide insight into the factors enhancing growth of intercultural sensitivity. Previous travel, characteristics of the home and host institutions, and the opportunity and willingness to be a cultural outsider were important influences.

  6. The International School Effectiveness Research Programme ISERP. First Results of the Quantitative Study.

    ERIC Educational Resources Information Center

    Creemers, Bert P. M.; And Others

    The International School Effectiveness Research Programme (ISERP) is an example of the exchange of research and research results in the field of educational effectiveness. It aims to build on existing models of good practice and to avoid the variations in approach that limit the transferability of data within and between countries. A number of…

  7. Current biomedical waste management practices and cross-infection control procedures of dentists in India.

    PubMed

    Singh, Balendra Pratap; Khan, Suleman A; Agrawal, Neeraj; Siddharth, Ramashanker; Kumar, Lakshya

    2012-06-01

    To investigate the knowledge, attitudes and behaviour of dentists working in dental clinics and dental hospitals regarding biomedical waste management and cross-infection control. A national survey was conducted. Self-administered questionnaires were sent to 800 dentists across India. A total of 494 dentists responded, giving a response rate of 61.8%. Of these, 228 of 323 (70.6%) general dentists reported using boiling water as a sterilising medium and 339 (68.6%) dentists reported disposing of hazardous waste such as syringes, blades and ampoules in dustbins and emptying these into municipal corporation bins. Dentists should undergo continuing education programmes on biomedical waste management and infection control guidelines. Greater cooperation between dental clinics and hospitals and pollution control boards is needed to ensure the proper handling and disposal of biomedical waste. © 2012 FDI World Dental Federation.

  8. Patterns of harm reduction service utilization and HIV incidence among people who inject drugs in Ukraine: A two-part latent profile analysis.

    PubMed

    Ompad, Danielle C; Wang, Jiayu; Dumchev, Konstantin; Barska, Julia; Samko, Maria; Zeziulin, Oleksandr; Saliuk, Tetiana; Varetska, Olga; DeHovitz, Jack

    2017-05-01

    Program utilization patterns are described within a large network of harm reduction service providers in Ukraine. The relationship between utilization patterns and HIV incidence is determined among people who inject drugs (PWID) controlling for oblast-level HIV incidence and treatment/syringe coverage. Data were extracted from the network's monitoring and evaluation database (January 2011-September 2014, n=327,758 clients). Latent profile analysis was used to determine harm reduction utilization patterns using the number of HIV tests received annually and the number of condoms, syringes, and services (i.e., information and counseling sessions) received monthly over a year. Cox proportional hazards regression determined the relations between HIV seroconversion and utilization class membership. In the final 4-class model, class 1 (34.0% of clients) received 0.1 HIV tests, 1.3 syringes, 0.6 condom and minimal counseling and information sessions per month; class 2 (33.6%) received 8.6 syringes, 3.2 condoms, and 0.5 HIV tests and counseling and information sessions; class 3 (19.1%) received 1 HIV test, 11.9 syringes, 4.3 condoms, and 0.7 information and counseling sessions; class 4 (13.3%) received 1 HIV test, 26.1 syringes, 10.3 condoms, and 1.8 information and 1.9 counseling sessions. Class 4 clients had significantly decreased risk for HIV seroconversion as compared to those in class 1 after controlling for oblast-level characteristics. Injection drug use continues to be a major mode of HIV transmission in Ukraine, making evaluation of harm reduction efforts in reducing HIV incidence among PWID critical. These analyses suggest that receiving more syringes and condoms decreased risk of HIV. Scaling up HIV testing and harm reduction services is warranted. Copyright © 2016. Published by Elsevier B.V.

  9. A new solid phase microextraction method using organic ligand in micropipette tip syringe system packed with modified carbon cloth for preconcentration of cadmium in drinking water and blood samples of kidney failure patients.

    PubMed

    Panhwar, Abdul Haleem; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Salma Aslam; Naeemullah; Brahman, Kapil Dev; Arain, Mariam Shahzadi

    2015-03-05

    A simple and efficient miniaturized solid phase microextraction (M-SPμE) in a syringe system was developed for preconcentration of cadmium (Cd) in environmental and biological samples, followed by flame atomic absorption technique. The syringe system contains the micropipette tip packed with activated carbon cloth, coated with modified magnetic nanoparticles of iron oxide Triton X114 (ACC-NPs). Scanning electron microscopy and energy dispersive spectroscopy used for characterization of the size, morphology and elemental composition of ACC-NPs. The sample solution treated with a complexing reagent 8-hydroxyqunilone (8-HQ), and drawn into the syringe, filled with ACC-MNPs and dispensed manually for 2-10 drawing/discharging cycles. The analyte retained on ACC-NPs in micropipette tip-syringe system were then eluted with different volume of 1.5molL(-1) HCl by 1-5 drawing/discharging cycles. The syringe system directly couple with FAAS for analysis. The influence of different variables on the extraction efficiency of Cd, including adsorbent dosage, pH, sample volume, eluent volume and drawing/discharging cycles of syringe system were optimized. At optimized extraction conditions, the method showed good linearity in the range of 5-250μgL(-1), with a limit of detection 0.15μgL(-1). Repeatability of the extraction (%RSD) was <5%, n=5. The validity and accuracy of the method was checked by the certified reference materials. The proposed method was successfully applied for the determination of Cd in different drinking water and biological samples of kidney failure patients and healthy controls. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A new solid phase microextraction method using organic ligand in micropipette tip syringe system packed with modified carbon cloth for preconcentration of cadmium in drinking water and blood samples of kidney failure patients

    NASA Astrophysics Data System (ADS)

    Panhwar, Abdul Haleem; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Salma Aslam; Naeemullah; Brahman, Kapil Dev; Arain, Mariam Shahzadi

    2015-03-01

    A simple and efficient miniaturized solid phase microextraction (M-SPμE) in a syringe system was developed for preconcentration of cadmium (Cd) in environmental and biological samples, followed by flame atomic absorption technique. The syringe system contains the micropipette tip packed with activated carbon cloth, coated with modified magnetic nanoparticles of iron oxide Triton X114 (ACC-NPs). Scanning electron microscopy and energy dispersive spectroscopy used for characterization of the size, morphology and elemental composition of ACC-NPs. The sample solution treated with a complexing reagent 8-hydroxyqunilone (8-HQ), and drawn into the syringe, filled with ACC-MNPs and dispensed manually for 2-10 drawing/discharging cycles. The analyte retained on ACC-NPs in micropipette tip-syringe system were then eluted with different volume of 1.5 mol L-1 HCl by 1-5 drawing/discharging cycles. The syringe system directly couple with FAAS for analysis. The influence of different variables on the extraction efficiency of Cd, including adsorbent dosage, pH, sample volume, eluent volume and drawing/discharging cycles of syringe system were optimized. At optimized extraction conditions, the method showed good linearity in the range of 5-250 μg L-1, with a limit of detection 0.15 μg L-1. Repeatability of the extraction (%RSD) was <5%, n = 5. The validity and accuracy of the method was checked by the certified reference materials. The proposed method was successfully applied for the determination of Cd in different drinking water and biological samples of kidney failure patients and healthy controls.

  11. Is point of access to needles and syringes related to needle sharing? Comparing data collected from pharmacies and needle and syringe programs in south-east Sydney.

    PubMed

    Bryant, Joanne; Topp, Libby; Hopwood, Max; Iversen, Jenny; Treloar, Carla; Maher, Lisa

    2010-07-01

    The comprehensive needle and syringe distribution system in New South Wales is partly based on the premise that different points of access to injecting equipment may attract different groups of injecting drug users. This paper examines patterns of equipment acquisition and risk for blood-borne virus transmission among injecting drug users who use pharmacies and needle and syringe programs (NSP) in south-east Sydney. Clients obtaining injecting equipment from four NSP (n = 147) and eight pharmacies (n = 227) in 2006 voluntarily completed a self-administered questionnaire. Respondents were grouped into three categories based on their needle and syringe acquisition patterns: exclusive use of NSP, exclusive use of pharmacies and use of both. Although it was common for respondents to report using both pharmacies and NSP to obtain needles and syringes (57%), a proportion reported exclusive use of pharmacies (17%) and NSP (14%). Exclusive pharmacy users were more likely to have never received treatment for their drug use and the least likely to have had a recent test for hepatitis C. Compared with respondents who exclusively used NSP, respondents who exclusively used pharmacies were more likely to report receptive sharing of injecting equipment (adjusted odds ratio 5.9, 95% confidence interval 2.02-17.14), as were respondents who reported using both sources (adjusted odds ratio 5.8, 95% confidence interval 2.35-14.40). The high prevalence of receptive equipment sharing among pharmacy clients indicates a need to improve access to needles and syringes and ancillary equipment, possibly by including ancillary equipment at no cost in existing pre-packaged pharmacy products.

  12. Distinguishing between microscale gaseous bubbles and liquid drops

    NASA Astrophysics Data System (ADS)

    Tan, Beng Hau; An, Hongjie; Chan, Chon U.; Ohl, Claus-Dieter

    2015-11-01

    In recent years, there has been strong research interest in decorating surfaces with tiny bubbles and drops due to their potential applications in reducing slippage in micro and nanofluidic devices. Both nanobubbles and nanodrops are typically nucleated by exchanging fluids over a suitable substrate. However, the nucleation experiments present many challenges, such as reproducibility and the possibility of contamination. The use of one-use plastic syringes and needle cannulas in nucleation experiments can introduce polymeric contamination. A contaminated experiment may nucleate bubbles, drops or both. Moreover, it is surprisingly difficult to distinguish between bubbles and drops under the usual atomic force microscopy or optical techniques. Here we present an experimental study comparing bubbles and oil (PDMS) drops on an atomically smooth surface (HOPG). Instead of nucleating the objects via solvent exchange, we directly introduced bubbles via electrolysis, and oil drops by injecting a dilute solution. Contrary to previous reports, we find that under careful AFM characterisation, liquid drops and gaseous bubbles respond differently to a change in imaging force, and moreover present different characteristic force curves.

  13. Aggregation and Particle Formation of Therapeutic Proteins in Contact With a Novel Fluoropolymer Surface Versus Siliconized Surfaces: Effects of Agitation in Vials and in Prefilled Syringes.

    PubMed

    Teska, Brandon M; Brake, Jeffrey M; Tronto, Gregory S; Carpenter, John F

    2016-07-01

    We examined the effects of an accelerated agitation protocol on 2 protein therapeutics, intravenous immunoglobulin (IVIG) and Avastin (bevacizumab), in contact with a novel fluoropolymer surface and more typical siliconized surfaces. The fluoropolymer surface provides "solid-phase" lubrication for the syringe plunger-obviating the need for silicone oil lubrication in prefilled syringes. We tested the 2 surfaces in a vial system and in prefilled glass syringes. We also examined the effects of 2 buffers, phosphate-buffered saline (PBS) and 0.2-M glycine, with and without the addition of polysorbate 20, on agitation-induced aggregation of IVIG. Aggregation was monitored by measuring subvisible particle formation and soluble protein loss. In both vials and syringes, protein particle formation was much lower during agitation with the fluoropolymer surface than with the siliconized surface. Also, particle formation was greater in PBS than in glycine buffer, an effect attributed to lower colloidal stability of IVIG in PBS. Polysorbate 20 in the formulation greatly inhibited protein particle formation. Overall, the fluoropolymer plunger surface in an unsiliconized glass barrel was demonstrated to be a viable solution for eliminating silicone oil droplets from prefilled syringe formulations and providing a consistent system for rationale formulation development and simplified particle analysis. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Cost comparison of methods for preparation of neonatal red cell aliquots.

    PubMed

    Lechuga, Diana; Thompson, Christina

    2007-01-01

    The purpose of this study was to compare the preparation costs of two common methods used for neonatal red blood cell transfusion aliquots. Three months of data from a Level 2 and Level 3 neonatal intensive care unit (NICU) were used to determine the comparative cost for red cell aliquot transfusions using an eight bag aliquot/transfer system or the syringe set system. Using leuko-poor red blood cell blood collected in Adsol and containing approximately 320 ml of red blood cells and supernatant solution, the average cost of neonatal transfusion aliquots was determined using the Charter Medical syringe set and the Charter Medical eight bag aliquot/transfer system. A total of 126 red blood cell transfusion aliquots were used over the three month period. The amount transfused with each aliquot ranged from 5.0 ml - 55.0 ml with an average of 24.0 ml per aliquot. The cost per aliquot using the eight aliquot/transfer set was calculated as $36.25 and the cost per aliquot using the syringe set cost was calculated as $30.71. Additional benefits observed with the syringe set included decreased blood waste. When comparing Charter Medical multiple aliquot bag sets and the Charter Medical syringe aliquot system to provide neonatal transfusions, the use of the syringe system decreased blood waste and proved more cost effective.

  15. An introduction to the Micrel Micropump MP Daily portable syringe driver.

    PubMed

    Groves, Karen E

    2003-11-01

    In this article the author describes the Micrel Micropump MP Daily (MP Daily) portable syringe driver. This follows the author's experience of a 4-month pilot of the device by an inpatient palliative care unit. Portable syringe drivers are commonly used to deliver continuous subcutaneous infusions in palliative care situations. Those in current use are not without problems and serious adverse events have occasionally been reported, mainly resulting from confusion between models. The MP Daily syringe driver addresses some of these issues while remaining small, lightweight and inexpensive, with a long battery life and fitting into the pocket of a shirt of pyjama jacket. Improvements over current models include an on/off button, the absence of facilities to set a zero rate or change the rate once the syringe driver is running, and the absence of a boost button. In addition, there are improved alarms, a message display system and a configuration menu. Although confusion remains a problem, and the ideal has not yet been reached, the MP Daily goes some considerable way towards reducing risks and opportunities for human error.

  16. Homicide by Sch from a syringe-like dart ejected by a compound crossbow.

    PubMed

    Guo, Wei; Luo, Guochang; Wang, Hao; Meng, Xiangzhi

    2015-02-01

    The compound crossbow can be used to eject syringe-like dart loaded with poisonous solution. Succinylcholine (Sch) is a short-acting neuromuscular blocker medically used to achieve complete relaxation of muscle for a good intubation condition. Without the help of an artificial respirator, intramuscular injection of a large dose of Sch can paralyze the respiratory muscle and result in the receiver's death. In this paper, we present the homicide case of a young male killed by Sch from a syringe-like dart ejected by a compound crossbow. The subcutaneous and muscular hemorrhages observed around the entry were more severe than that caused by a medical injection. Additionally, other autopsy results showed the external appearance of a pinhole, general asphyxia signs and pathological findings which were not characteristic. The discovery of a syringe-like dart at the scene is the critical clue and reason for analyzing for Sch, which is commonly used to load syringe-like dart to paralyze and steal dog in the countryside of China. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  17. Pain associated with local anesthetic injection in eyelid procedures: Comparison of microprocessor-controlled versus traditional syringe techniques.

    PubMed

    Lee, Edward W; Tucker, Nancy A

    2007-01-01

    To evaluate the pain associated with local infiltration of the eyelid, using a microprocessor-controlled delivery system (CompuMed, using the Wand), as compared with traditional manual syringe infiltration technique. A randomized clinical trial of 30 patients undergoing minor eyelid surgical procedures was performed. Fifteen patients were injected by use of the CompuMed system and 15 patients were injected by the traditional manual syringe technique. The severity of pain was recorded from each patient by using a visual analog scale (0 to 10). The duration of pain experienced by the patient was also recorded. The mean pain level reported was 1.5 in the Wand group and 3.2 in the syringe group (p < 0.01). The mean duration of pain experienced was 1.5 seconds in the Wand group and 34 seconds in the syringe group (p < 0.01). The Wand was effective at significantly reducing the pain associated with local anesthetic infiltration in minor eyelid surgical procedures. Patients appear to feel pain from the initial needle stick but not during the actual injection.

  18. The benefits and drawbacks of syringe drivers in palliative care.

    PubMed

    Costello, John; Nyatanga, Brian; Mula, Carole; Hull, Jenny

    2008-03-01

    This article will outline the use of continuous subcutaneous infusion pumps, known as syringe drivers, including their benefits and drawbacks in a palliative care context. There have been over 5000 articles published globally describing syringe drivers in the medical and nursing literature within the last decade. Many provide guidance on their use, although much of the data are repetitious, disease or age-group specific, and focused on pragmatic issues to do with clinical application. Several trusts and hospices across the UK are carrying out trials of the recently launched McKinley T34 syringe driver. Therefore, it seems timely to consider their wider use internationally. Globally, practitioners in palliative care are very familiar with their use, although the literature lacks specific guidance and, at times, the information is ambiguous. Having briefly reviewed their benefits, the article considers the limitations of using syringe drivers and comments on some of the lesser known/reported practical and patient-focused drawbacks associated with their use. We conclude by considering why, when so much education and training exists to help practitioners use these devices effectively, so many human errors occur.

  19. Open-Source Syringe Pump Library

    PubMed Central

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  20. Assessing seasonality of travel distance to harm reduction service providers among persons who inject drugs.

    PubMed

    Allen, Sean T; Ruiz, Monica S; Roess, Amira; Jones, Jeff

    2015-10-12

    Prior research has examined access to syringe exchange program (SEP) services among persons who inject drugs (PWID), but no research has been conducted to evaluate variations in SEP access based on season. This is an important gap in the literature given that seasonal weather patterns and inclement weather may affect SEP service utilization. The purpose of this research is to examine differences in access to SEPs by season among PWID in the District of Columbia (DC). A geometric point distance estimation technique was applied to records from a DC SEP that operated from 1996 to 2011. We calculated the walking distance (via sidewalks) from the centroid point of zip code of home residence to the exchange site where PWID presented for services. Analysis of variance (ANOVA) was used to examine differences in walking distance measures by season. Differences in mean walking distance measures were statistically significant between winter and spring with PWID traveling approximately 2.88 and 2.77 miles, respectively, to access the SEP during these seasons. The results of this study suggest that seasonal differences in SEP accessibility may exist between winter and spring. PWID may benefit from harm reduction providers adapting their SEP operations to provide a greater diversity of exchange locations during seasons in which inclement weather may negatively influence engagement with SEPs. Increasing the number of exchange locations based on season may help resolve unmet needs among injectors.

  1. Air-gas exchange reevaluated: clinically important results of a computer simulation.

    PubMed

    Shunmugam, Manoharan; Shunmugam, Sudhakaran; Williamson, Tom H; Laidlaw, D Alistair

    2011-10-21

    The primary aim of this study was to evaluate the efficiency of air-gas exchange techniques and the factors that influence the final concentration of an intraocular gas tamponade. Parameters were varied to find the optimum method of performing an air-gas exchange in ideal circumstances. A computer model of the eye was designed using 3D software with fluid flow analysis capabilities. Factors such as angular distance between ports, gas infusion gauge, exhaust vent gauge and depth were varied in the model. Flow rate and axial length were also modulated to simulate faster injections and more myopic eyes, respectively. The flush volume of gas required to achieve a 97% intraocular gas fraction concentration were compared. Modulating individual factors did not reveal any clinically significant difference in the angular distance between ports, exhaust vent size, and depth or rate of gas injection. In combination, however, there was a 28% increase in air-gas exchange efficiency comparing the most efficient with the least efficient studied parameters in this model. The gas flush volume required to achieve a 97% gas fill also increased proportionately at a ratio of 5.5 to 6.2 times the volume of the eye. A 35-mL flush is adequate for eyes up to 25 mm in axial length; however, eyes longer than this would require a much greater flush volume, and surgeons should consider using two separate 50-mL gas syringes to ensure optimal gas concentration for eyes greater than 25 mm in axial length.

  2. Understanding the drivers of interprofessional collaborative practice among HIV primary care providers and case managers in HIV care programmes.

    PubMed

    Mavronicolas, Heather A; Laraque, Fabienne; Shankar, Arti; Campbell, Claudia

    2017-05-01

    Care coordination programmes are an important aspect of HIV management whose success depends largely on HIV primary care provider (PCP) and case manager collaboration. Factors influencing collaboration among HIV PCPs and case managers remain to be studied. The study objective was to test an existing theoretical model of interprofessional collaborative practice and determine which factors play the most important role in facilitating collaboration. A self-administered, anonymous mail survey was sent to HIV PCPs and case managers in New York City. An adapted survey instrument elicited information on demographic, contextual, and perceived social exchange (trustworthiness, role specification, and relationship initiation) characteristics. The dependent variable, perceived interprofessional practice, was constructed from a validated scale. A sequential block wise regression model specifying variable entry order examined the relative importance of each group of factors and of individual variables. The analysis showed that social exchange factors were the dominant drivers of collaboration. Relationship initiation was the most important predictor of interprofessional collaboration. Additional influential factors included organisational leadership support of collaboration, practice settings, and frequency of interprofessional meetings. Addressing factors influencing collaboration among providers will help public health programmes optimally design their structural, hiring, and training strategies to foster effective social exchanges and promote collaborative working relationships.

  3. An Evaluation of the Effectiveness of a Vibrating Syringe Attachment in Decreasing Intraoral Injection Pain Perception

    DTIC Science & Technology

    2012-06-01

    mucosa penetrations to periosteum by a 27-gauge short needle attached to a dental cartridge syringe . New needles were used for each injection, and the...of the American Dental Association, 134(2), 228-234. 7. Bonjar AHS. (2011) Syringe micro vibrator (SMV) a new device being introduced in dentistry...Lautenbacher S. (2004) Pathophysiology of Pain Perception. New York , New York : Kluwer and Plenum. 16 Flanagan T, Wahl MJ, Schmitt MM, Wahl JA. (2007) Size

  4. An Approach to the Internationalisation of the Curriculum: Sino-British Joint Efforts for Three Online Courses

    ERIC Educational Resources Information Center

    Yawan, Li; Ying, Li

    2011-01-01

    With a view to facilitating good practice and enhancing further exchanges and collaboration with the Open University UK, the Open University of China initiated a joint programme of training to offer online tutors and academic management staff three courses: Student Support, Tutoring On-line, and Course Design. The programme brought in not only a…

  5. "Tapestry" and the Aesthetics of Theatre in Education as Dialogic Encounter and Civil Exchange

    ERIC Educational Resources Information Center

    Winston, Joe; Strand, Steve

    2013-01-01

    This article is based upon research into a participatory Theatre in Education (TiE) programme that toured the West Midlands in 2009, funded by the UK's PREVENT initiative intended to counter the radicalisation of young British nationals by extremist political groups. The article provides a summary of the TiE programme and then presents…

  6. Innovation and Alliances in International Management Programmes; Redefining and Extending the Model. The "Transcontinental Tracks" at Grenoble EM

    ERIC Educational Resources Information Center

    Thomas, Mark; O'Sullivan, Patrick; Zahner, Martin; Silvestre, Joelle

    2015-01-01

    Purpose: The purpose of this paper is to describe an innovative international management programme that has been developed across four countries for Master-level students. It first analyses the advantages and disadvantages of two of the most common forms of internationalisation in higher education; the student exchange and full-scale offshore…

  7. Hep-CORE: a cross-sectional study of the viral hepatitis policy environment reported by patient groups in 25 European countries in 2016 and 2017.

    PubMed

    Lazarus, Jeffrey V; Stumo, Samya R; Harris, Magdalena; Hendrickx, Greet; Hetherington, Kristina L; Maticic, Mojca; Jauffret-Roustide, Marie; Tallada, Joan; Simojoki, Kaarlo; Reic, Tatjana; Safreed-Harmon, Kelly

    2018-04-01

    The first World Health Organization (WHO) global health sector strategy on hepatitis B and C viruses (HBV and HCV) has called for the elimination of viral hepatitis as a major public health threat by 2030. This study assesses policies and programmes in support of elimination efforts as reported by patient groups in Europe. In 2016 and 2017, hepatitis patient groups in 25 European countries participated in a cross-sectional survey about their countries' policy responses to HBV and HCV. The English-language survey addressed overall national response; public awareness/engagement; disease monitoring; prevention; testing/diagnosis; clinical assessment; and treatment. We performed a descriptive analysis of data and compared 2016 and 2017 findings. In 2017, 72% and 52% of the 25 European study countries were reported to not have national HBV and HCV strategies respectively. The number of respondents indicating that their governments collaborated with civil society on viral hepatitis control increased from 13 in 2016 to 18 in 2017. In both 2016 and 2017, patient groups reported that 9 countries (36%) have disease registers for HBV and 11 (44%) have disease registers for HCV. The number of countries reported to have needle and syringe exchange programmes available in all parts of the country dropped from 10 (40%) in 2016 to 8 in 2017 (32%). In both 2016 and 2017, patient groups in 5 countries (20%) reported that HCV treatment is available in non-hospital settings. From 2016 to 2017, the reported number of countries with no restrictions on access to direct-acting antivirals for HCV increased from 3 (12%) to 7 (28%), and 5 fewer countries were reported to refuse treatment to people who are currently injecting drugs. The patient-led Hep-CORE study offers a unique perspective on the readiness of study countries to undertake comprehensive viral hepatitis elimination efforts. Viral hepatitis monitoring should be expanded to address policy issues more comprehensively and to incorporate civil society perspectives, as is the case with global HIV monitoring. Policy components should also be explicitly added to the WHO framework for monitoring country-level progress against viral hepatitis. © 2018 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  8. Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot‐humid environment

    PubMed Central

    Baker, Lindsay B.; Ungaro, Corey T.; Barnes, Kelly A.; Nuccio, Ryan P.; Reimel, Adam J.; Stofan, John R.

    2014-01-01

    Abstract This study compared a field versus reference laboratory technique for extracting (syringe vs. centrifuge) and analyzing sweat [Na+] and [K+] (compact Horiba B‐722 and B‐731, HORIBA vs. ion chromatography, HPLC) collected with regional absorbent patches during exercise in a hot‐humid environment. Sweat samples were collected from seven anatomical sites on 30 athletes during 1‐h cycling in a heat chamber (33°C, 67% rh). Ten minutes into exercise, skin was cleaned/dried and two sweat patches were applied per anatomical site. After removal, one patch per site was centrifuged and sweat was analyzed with HORIBA in the heat chamber (CENTRIFUGE HORIBA) versus HPLC (CENTRIFUGE HPLC). Sweat from the second patch per site was extracted using a 5‐mL syringe and analyzed with HORIBA in the heat chamber (SYRINGE HORIBA) versus HPLC (SYRINGE HPLC). CENTRIFUGE HORIBA, SYRINGE HPLC, and SYRINGE HORIBA were highly related to CENTRIFUGE HPLC ([Na+]: ICC = 0.96, 0.94, and 0.93, respectively; [K+]: ICC = 0.87, 0.92, and 0.84, respectively), while mean differences from CENTRIFUGE HPLC were small but usually significant ([Na+]: 4.7 ± 7.9 mEql/L, −2.5 ± 9.3 mEq/L, 4.0 ± 10.9 mEq/L (all P < 0.001), respectively; [K+]: 0.44 ± 0.52 mEq/L (P < 0.001), 0.01 ± 0.49 mEq/L (P = 0.77), 0.50 ± 0.48 mEq/L (P < 0.001), respectively). On the basis of typical error of the measurement results, sweat [Na+] and [K+] obtained with SYRINGE HORIBA falls within ±15.4 mEq/L and ±0.68 mEq/L, respectively, of CENTRIFUGE HPLC 95% of the time. The field (SYRINGE HORIBA) method of extracting and analyzing sweat from regional absorbent patches may be useful in obtaining sweat [Na+] when rapid estimates in a hot‐humid field setting are needed. PMID:24793982

  9. Stability of nitroglycerin 110 mcg/mL stored in polypropylene syringes.

    PubMed

    McCluskey, Susan V; Vu, Nicole; Rueter, John

    2013-01-01

    Various angiography procedures at Mayo Clinic (Rochester campus) require small bolus doses of injectable nitroglycerin. Commercially acquired containers of injectable nitroglycerin provide excessive amounts of drug for these procedural needs, so syringes were chosen as a container for dispensing of the dose needed. Due to nitroglycerin's known chemical attributes of volatility and sorption to plastic surfaces, careful consideration of the stability needs to be taken into account when storing in a syringe. Since there is a lack of stability information in the literature, we studied the stability of nitroglycerin in polypropylene syringes over 90 days. Methods used for this study consisted of a validated stability-indicating high-performance liquid chromatographic assay, visual appearance, and pH. Samples were stored protected from light at ambient controlled temperature and consisted of nitroglycerin 110 mcg/mL in 5% dextrose injection 10.1 mL in 12 mL Terumo polypropylene syringes. Samples were tested at intervals up to 90 days. Results from the visual portion of the study showed clear, colorless, and particulate-free solutions throughout the 90-day study period. The pH results started at 4.27 +/- 0.13 (day 0) and ranged from 4.19 +/- 0.17 to 4.92 +/- 0.43 throughout the study period. Potency test results revealed a day 0 concentration of 104.242 +/- 0.193 mcg/mL (batch 1) and 122.483 +/- 0.168 mcg/mL (batch 2). Results trended downward with percentage of day 0 concentration of 92.2% +/- 2.4% at day 14 and of 81.4% +/- 4.9% at day 90. Chromatographic profiles of the samples exhibited insignificant changes over the study period. The nitroglycerin peak was spectrally pure based on peak-purity analysis, suggesting that sorption to the polypropylene syringe is one possible reason for the concentration decline over time, but nitroglycerin is a volatile compound and loss through vaporization cannot be ruled out. Nitroglycerin 110 mcg/mL in 5% dextrose injection, packaged in Terumo polypropylene syringes with 10.1 mL aliquots, maintained 90% of syringe potency for 24 days when stored protected from light under controlled ambient conditions.

  10. Self-powered switch-controlled nucleic acid extraction system.

    PubMed

    Han, Kyungsup; Yoon, Yong-Jin; Shin, Yong; Park, Mi Kyoung

    2016-01-07

    Over the past few decades, lab-on-a-chip (LOC) technologies have played a great role in revolutionizing the way in vitro medical diagnostics are conducted and transforming bulky and expensive laboratory instruments and labour-intensive tests into easy to use, cost-effective miniaturized systems with faster analysis time, which can be used for near-patient or point-of-care (POC) tests. Fluidic pumps and valves are among the key components for LOC systems; however, they often require on-line electrical power or batteries and make the whole system bulky and complex, therefore limiting its application to POC testing especially in low-resource setting. This is particularly problematic for molecular diagnostics where multi-step sample processing (e.g. lysing, washing, elution) is necessary. In this work, we have developed a self-powered switch-controlled nucleic acid extraction system (SSNES). The main components of SSNES are a powerless vacuum actuator using two disposable syringes and a switchgear made of PMMA blocks and an O-ring. In the vacuum actuator, an opened syringe and a blocked syringe are bound together and act as a working syringe and an actuating syringe, respectively. The negative pressure in the opened syringe is generated by a restoring force of the compressed air inside the blocked syringe and utilized as the vacuum source. The Venus symbol shape of the switchgear provides multiple functions including being a reagent reservoir, a push-button for the vacuum actuator, and an on-off valve. The SSNES consists of three sets of vacuum actuators, switchgears and microfluidic components. The entire system can be easily fabricated and is fully disposable. We have successfully demonstrated DNA extraction from a urine sample using a dimethyl adipimidate (DMA)-based extraction method and the performance of the DNA extraction has been confirmed by genetic (HRAS) analysis of DNA biomarkers from the extracted DNAs using the SSNES. Therefore, the SSNES can be widely used as a powerless and disposable system for DNA extraction and the syringe-based vacuum actuator would be easily utilized for diverse applications with various microchannels as a powerless fluidic pump.

  11. Injecting 1000 centistoke liquid silicone with ease and precision.

    PubMed

    Benedetto, Anthony V; Lewis, Alan T

    2003-03-01

    Since the Food and Drug Administration approved the use of the 1000 centistoke liquid silicone, Silikon 1000, for intraocular injection, the off-label use of this injectable silicone oil as a permanent soft-tissue filler for facial rejuvenation has increased in the United States. Injecting liquid silicone by the microdroplet technique is the most important preventive measure that one can use to avoid the adverse sequelae of silicone migration and granuloma formation, especially when injecting silicone to improve small facial defects resulting from acne scars, surgical procedures, or photoaging. To introduce an easy method for injecting a viscous silicone oil by the microdroplet technique, using an inexpensive syringe and needle that currently is available from distributors of medical supplies in the United States. We suggest the use of a Becton Dickinson 3/10 cc insulin U-100 syringe to inject Silikon 1000. This syringe contains up to 0.3 mL of fluid, and its barrel is clearly marked with an easy-to-read scale of large cross-hatches. Each cross-hatch marking represents either a unit value of 0.01 mL or a half-unit value of 0.005 mL of fluid, which is the approximate volume preferred when injecting liquid silicone into facial defects. Because not enough negative pressure can be generated in this needle and syringe to draw up the viscous silicone oil, we describe a convenient and easy method for filling this 3/10 cc diabetic syringe with Silikon 1000. We have found that by using the Becton Dickinson 3/10 cc insulin U-100 syringe, our technique of injecting minute amounts of Silikon 1000 is facilitated because each widely spaced cross-hatch on the side of the syringe barrel is easy to read and measures exact amounts of the silicone oil. These lines of the scale on the syringe barrel are so large and clearly marked that it is virtually impossible to overinject the most minute amount of silicone. Sequential microdroplets of 0.01 cc or less of Silikon 1000 can be measured and injected with the greatest ease and precision so that inadvertent overdosing and complications can be avoided.

  12. Measuring individual-level needle and syringe coverage among people who inject drugs in Myanmar.

    PubMed

    O'Keefe, Daniel; Aung, Soe Moe; Pasricha, Naanki; Wun, Thu; Linn, Soe Khaing; Lin, Nay; Aitken, Campbell; Hughes, Chad; Dietze, Paul

    2018-05-10

    Myanmar has prioritised people who inject drugs (PWID) as a key population for HIV mitigation efforts, with targets for needle and syringe distribution set at a population level. However, individual-level coverage, defined as the percentage of an individual's injecting episodes covered by a sterile syringe, is a more sensitive measure of intervention coverage. We sought to examine individual-level coverage in a sample of PWID in Myanmar. We recruited 512 PWID through urban drop-in-centres in Yangon, Mandalay and Pyin Oo Lwin. Participants were administered a quantitative questionnaire covering five domains: demographics, drug use, treatment and coverage, and injecting risk behaviour. We calculated past fortnight individual-level syringe coverage, estimating levels of sufficient (≥100% of injecting episodes covered by a sterile syringe) and insufficient (<100%) coverage, and examined associations between key variables and insufficient coverage via logistic regression. Our sample was predominately male (97%), employed (76%), and living in stable accommodation (96%), with a median age of 27. All participants reported heroin as the drug most frequently injected, and injected a median of 27 times in the past two weeks. Nineteen per cent of participants had insufficient coverage in the two weeks before interview. Insufficient coverage was positively associated with syringe re-use (AOR: 5.19, 95% CIs: 2.57, 10.48) and acquiring sterile syringes from a location other than a formal drop-in-centre (AOR: 2.04, 95% CIs: 1.08, 3.82). Participants recruited in Mandalay (AOR: 0.30, 95% CIs: 0.11, 0.80) and Pyin Oo Lwin (AOR: 0.39, 95% CIs: 0.18, 0.87) had lower odds of insufficient coverage than those recruited in Yangon. Our study shows coverage in selected areas of Myanmar was comparable with studies in other countries. Our results inform the delivery of harm reduction services for PWID, specifically by encouraging the use of formal drop-in-centres, over other sources of syringe distribution, such as pharmacies. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Benefits/problems of enhancing students' intercultural competence.

    PubMed

    Koskinen, Liisa; Tossavainen, Kerttu

    European nursing has responded to the challenges of multicultural society by integrating student exchange programmes into nursing education since the 1990s. For students, these programmes provide opportunities to study in another EU member state and to develop intercultural competence as part of the training. The aim of this study was to describe the process of gaining intercultural competence among British undergraduate nursing students during their study abroad in Finland. Fifteen British students participated in this study. Data were obtained from interviews, observations, background questionnaires and research diary notes. The data were analysed with Spradley's developmental research sequence (DRS) method. Campinha-Bacotes' model of cultural competence was used as a framework of rendering the results. Students' intercultural desire, i.e. their effort to become interculturally competent, turned out to be the foundation of the entire process. Study abroad is an intensive experience, and therefore the preparation, the selection of exchange students, the design of the programme and intercultural tutoring warrant careful attention.

  14. [Health coaching as a part of integration into the job market--evaluation of a qualification concept].

    PubMed

    Heinmüller, M; Liel, K; Angerer, P; Gündel, H; Geldermann, B; Gottwald, M; Kimil, A; Limm, H

    2014-03-01

    The aim of this study is to develop, implement and evaluate an education programme enabling the pedagogic staff of employment promotion agencies to integrate health promotion approaches und activities in vocational training programmes. The evaluation of the education programme is based on Kirkpatrick's 4 levels training evaluation model. Besides the participants' verbal end of session feedback, a standardised questionnaire was used at the end of the education programme and after 3 months practical experience. Process evaluation included the implementation level of the methods learned. From a total of 71 participants, 56 completed the first and 31 the second questionnaire (return rate 79% and 44%, respectively). The participants' mean age was 42 years, 80% were female. Only 22% of them integrated health topics systematically into their daily work. A 3-day basic training followed by case conferences during practical work was developed to transfer knowledge and practical competence in person-to-person talks and group activities (so called FIT-counselling and FIT-group). For 96% of participants, their expectations regarding the education programme were met completely or predominantly. 91% indicated a rise in motivation to work as health coach. When rating the training material, 96% judged it helpful for implementation/transfer. Many participants marked the education programme as being too short and wished more time for the topic of "mental health" and exchange of experiences. The follow-up after 3 months on-the-job training revealed that 84 and 97%, respectively, found FIT-counselling and FIT-groups helpful for their daily work. In all employment promotion agencies FIT-counselling and FIT-groups were implemented. Our results affirm the need for and prove the acceptance of education programmes enabling the pedagogic staff of job-training programmes to deliver health coaching. Periodic case conferences take into account the participants' request for more exchange of experiences, facilitate implementation and contribute to quality and sustainability. Further development of the education programme is ongoing. © Georg Thieme Verlag KG Stuttgart · New York.

  15. 21 CFR 522.2662 - Xylazine.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., by hand syringe, or by syringe dart, in the heavy muscles of the croup or shoulder as follows: (A... procedures, for therapeutic medication for sedation and relief of pain following injury or surgery, and as a...

  16. 21 CFR 522.2662 - Xylazine.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., by hand syringe, or by syringe dart, in the heavy muscles of the croup or shoulder as follows: (A... procedures, for therapeutic medication for sedation and relief of pain following injury or surgery, and as a...

  17. Application of a Sex Pheromone, Pheromone Analogs, and Verticillium lecanii for Management of Heterodera glycines

    PubMed Central

    Meyer, S. L. F.; Huettel, R. N.

    1996-01-01

    A mutant strain of the fungus Verticillium lecanii and selected bioregulators of Heterodera glycines were evaluated for their potential to reduce population densities of the nematode on soybean under greenhouse conditions. The bioregulators tested were the H. glycines sex pheromone vanillic acid and the pheromone analogs syringic acid, isovanillic acid, ferulic acid, 4-hydroxy-3-methoxybenzonitrile, and methyl vanillate. A V. lecanii-vanillic acid combination and a V. lecanii-syringic acid combination were also applied as treatments. Syringic acid, 4-hydroxy-3-methoxybenzonitrile, V. lecanii, V. lecanii-vanillic acid, and V. lecanii-syringic acid significantly reduced nematode population densities in the greenhouse tests. Results with vanillic acid, isovanillic acid, and ferulic acid treatments were variable. Methyl vanillate did not significantly reduce cyst nematode population densities in the greenhouse tests. PMID:19277343

  18. Stability of micafungin sodium solutions at different concentrations in glass bottles and syringes.

    PubMed

    Briot, Thomas; Vrignaud, Sandy; Lagarce, Frédéric

    2015-08-15

    Micafungin is a costly treatment and packaging of 50 mg or 100 mg bottles only are available, while doses lower than 5 mg and 20 mg are often necessary in neonates and paediatrics patients, respectively. The stability of micafungin sodium in polypropylene syringes and glass bottles was studied at different concentrations. Solutions of micafungin diluted with NaCl 0.9% were prepared in glass bottles (20 and 10 mg/mL) or syringes (1 and 0.5 mg/mL) and stored at 25 °C, 60% humidity (RH), in the dark (ICH conditions). Solutions were also exposed to heat (70 °C) or alkaline solution (NaOH) in order to force degradation. Samples were analysed at days 1, 5, 8 (for bottles) and also 15 (for syringes) after the preparation and assayed in triplicate. Stability was studied using a stability-indicating high-performance liquid chromatographic method. Syringes stored at 25 °C retained over 90% of their initial concentration over the study period. Temperature and alkaline conditions had significant effect on the stability of micafungin, leading to apparition of degradation products. Moreover, sub visible particles were in the specification of the European Pharmacopeia along 15 days. To conclude, micafungin diluted in NaCl 0.9% and stored in polypropylene syringes was chemically stable for at least 15 days at 25 °C in the dark. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Policing behaviors, safe injection self-efficacy, and intervening on injection risks: Moderated mediation results from a randomized trial.

    PubMed

    Pitpitan, Eileen V; Patterson, Thomas L; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A

    2016-01-01

    We aim to use conditional or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico, and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. In total, 213 women provided complete data for the current analyses. Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = .04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = .04). Whereas syringe confiscation by the police negatively affected safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to "buffer" this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants' self-efficacy for safer injection in the face of syringe confiscation. (c) 2015 APA, all rights reserved).

  20. Non-prescription Syringe Sales in California: A Qualitative Examination of Practices among 12 Local Health Jurisdictions

    PubMed Central

    Backes, Glenn; Martinez, Alexis; McFarland, Willi

    2010-01-01

    Legislation permitting non-prescription syringe sales (NPSS) was passed in 2004 in California as a structural intervention designed to expand access to syringes for injection drug users. As of December 2009, 19 of California’s 61 local health jurisdictions (LHJs) have approved policies to authorize pharmacies to sell non-prescription syringes. The legislation faces termination in 2010 if current evaluation efforts fail to demonstrate outcomes defined in the legislation. Using qualitative methods, we examined the systems and procedures associated with implementation; identified facilitators and barriers to implementation among 12 LHJs, and documented the role of public health in initiating and sustaining local programs. We identified consistent activities that led to policy implementation among LHJs and discovered several barriers that were associated with failure to implement local programs. Factors leading to NPSS were public health leadership; an inclusive planning process, marketing the program as a public health initiative; learning from others’ efforts, successes, and failures; and identifying acceptable syringe disposal options in advance of program implementation. Health departments that were confronted with political and moral arguments lost momentum and ultimately assigned a lower priority to the initiative citing the loss of powerful public health advocates or a lack of human resources. Additional barriers were law enforcement, elected officials, and pharmacy opposition, and failure to resolve syringe disposal options to the satisfaction of important stakeholders. The lessons learned in this study should provide useful guidance for the remaining LHJs in California without NPSS programs. PMID:20405227

  1. Non-prescription syringe sales in California: a qualitative examination of practices among 12 local health jurisdictions.

    PubMed

    Rose, Valerie J; Backes, Glenn; Martinez, Alexis; McFarland, Willi

    2010-07-01

    Legislation permitting non-prescription syringe sales (NPSS) was passed in 2004 in California as a structural intervention designed to expand access to syringes for injection drug users. As of December 2009, 19 of California's 61 local health jurisdictions (LHJs) have approved policies to authorize pharmacies to sell non-prescription syringes. The legislation faces termination in 2010 if current evaluation efforts fail to demonstrate outcomes defined in the legislation. Using qualitative methods, we examined the systems and procedures associated with implementation; identified facilitators and barriers to implementation among 12 LHJs, and documented the role of public health in initiating and sustaining local programs. We identified consistent activities that led to policy implementation among LHJs and discovered several barriers that were associated with failure to implement local programs. Factors leading to NPSS were public health leadership; an inclusive planning process, marketing the program as a public health initiative; learning from others' efforts, successes, and failures; and identifying acceptable syringe disposal options in advance of program implementation. Health departments that were confronted with political and moral arguments lost momentum and ultimately assigned a lower priority to the initiative citing the loss of powerful public health advocates or a lack of human resources. Additional barriers were law enforcement, elected officials, and pharmacy opposition, and failure to resolve syringe disposal options to the satisfaction of important stakeholders. The lessons learned in this study should provide useful guidance for the remaining LHJs in California without NPSS programs.

  2. Policing Behaviors, Safe Injection Self-Efficacy, and Intervening on Injection Risks: Moderated Mediation Results from a Randomized Trial

    PubMed Central

    Pitpitan, Eileen V.; Patterson, Thomas L.; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A.

    2015-01-01

    Objective We aim to use conditional, or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Methods Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator, and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. 213 women provided complete data for the current analyses. Results Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = 0.04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = 0.04). Conclusions Whereas syringe confiscation by the police negatively impacted safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to “buffer” this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants’ self-efficacy for safer injection in the face of syringe confiscation. PMID:26120851

  3. Rapid discrimination and determination of antibiotics drugs in plastic syringes using near infrared spectroscopy with chemometric analysis: Application to amoxicillin and penicillin.

    PubMed

    Lê, Laetitia Minh Mai; Eveleigh, Luc; Hasnaoui, Ikram; Prognon, Patrice; Baillet-Guffroy, Arlette; Caudron, Eric

    2017-05-10

    The aim of this study was to investigate near infrared spectroscopy (NIRS) combined to chemometric analysis to discriminate and quantify three antibiotics by direct measurement in plastic syringes.Solutions of benzylpenicillin (PENI), amoxicillin (AMOX) and amoxicillin/clavulanic acid (AMOX/CLAV) were analyzed at therapeutic concentrations in glass vials and plastic syringes with NIR spectrometer by direct measurement. Chemometric analysis using partial least squares regression and discriminative analysis was conducted to develop qualitative and quantitative calibration models. Discrimination of the three antibiotics was optimal for concentrated solutions with 100% of accuracy. For quantitative analysis, the three antibiotics furnished a linear response (R²>0.9994) for concentrations ranging from 0.05 to 0.2 g/mL for AMOX, 0.1 to 1.0 MUI/mL for PENI and 0.005 to 0.05 g/mL for AMOX/CLAV with excellent repeatability (maximum 1.3%) and intermediate precision (maximum of 3.2%). Based on proposed models, 94.4% of analyzed AMOX syringes, 80.0% of AMOX/CLAV syringes and 85.7% of PENI syringes were compliant with a relative error including the limit of ± 15%.NIRS as rapid, non-invasive and non-destructive analytical method represents a potentially powerful tool to further develop for securing the drug administration circuit of healthcare institutions to ensure that patients receive the correct product at the right dose. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Assessment of human resources for health programme implementation in 15 Latin American and Caribbean countries.

    PubMed

    Dal Poz, Mario Roberto; Sepulveda, Hernan Rodrigo; Costa Couto, Maria Helena; Godue, Charles; Padilla, Monica; Cameron, Rick; Vidaurre Franco, Thais de Andrade

    2015-04-28

    The health systems in the Americas region are characterized by fragmentation and segmentation, which constitute an important barrier to expanding coverage, achieving integrated primary health care, and reducing inefficiency and discontinuity of care. An assessment of the human resources for health (HRH) programmes that have been implemented at the country level was developed as part of the measurement of the 20 HRH regional goals for 2007-2015, adopted in 2007 by the Pan American Sanitary Conference (CSPA). The exercise was a combination of academic research and the development/application of an advocacy tool involving policy makers and stakeholders to influence the decision-making in the development, implementation, or change of HRH programmes while building evidence through a structured approach based on qualitative and quantitative information and the exchange and dissemination of best practices. This paper covers the methodological challenges, as well as a summary of the main findings of the study, which included 15 countries: Belize, Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua and Panama in the Central America, Dominican Republic in the Caribbean, Chile, Colombia, Ecuador and Peru in the Andean sub region, and Argentina, Paraguay, and Uruguay in the South Cone. Despite the different contexts, the results showed that the programmes evaluated faced common challenges, such as lack of political support and financial unsustainability. The evaluation process allowed the exchange and dissemination of practices, interventions, and programmes currently running in the region. A shared lesson was the importance of careful planning of the implementation of programmes and interventions. The similarities in the problems and challenges of HRH among the participating countries highlighted the need for a cooperation programme on the evaluation and assessment of implementation strategies in the Americas region.

  5. The law (and politics) of safe injection facilities in the United States.

    PubMed

    Beletsky, Leo; Davis, Corey S; Anderson, Evan; Burris, Scott

    2008-02-01

    Safe injection facilities (SIFs) have shown promise in reducing harms and social costs associated with injection drug use. Favorable evaluations elsewhere have raised the issue of their implementation in the United States. Recognizing that laws shape health interventions targeting drug users, we analyzed the legal environment for publicly authorized SIFs in the United States. Although states and some municipalities have the power to authorize SIFs under state law, federal authorities could still interfere with these facilities under the Controlled Substances Act. A state- or locally-authorized SIF could proceed free of legal uncertainty only if federal authorities explicitly authorized it or decided not to interfere. Given legal uncertainty, and the similar experience with syringe exchange programs, we recommend a process of sustained health research, strategic advocacy, and political deliberation.

  6. Addressing the HIV/AIDS epidemic among Puerto Rican people who inject drugs: the need for a multiregion approach.

    PubMed

    Deren, Sherry; Gelpí-Acosta, Camila; Albizu-García, Carmen E; González, Ángel; Des Jarlais, Don C; Santiago-Negrón, Salvador

    2014-11-01

    High levels of HIV risk behaviors and prevalence have been reported among Puerto Rican people who inject drugs (PRPWID) since early in the HIV epidemic. Advances in HIV prevention and treatment have reduced HIV among people who inject drugs (PWID) in the United States. We examined HIV-related data for PRPWID in Puerto Rico and the US Northeast to assess whether disparities continue. Injection drug use as a risk for HIV is still overrepresented among Puerto Ricans. Lower availability of syringe exchanges, drug abuse treatment, and antiretroviral treatment for PWID in Puerto Rico contribute to higher HIV risk and incidence. These disparities should be addressed by the development of a federally supported Northeast-Puerto Rico collaboration to facilitate and coordinate efforts throughout both regions.

  7. Occurrence of coring after needle insertion through a rubber stopper: study with prednisolone acetate.

    PubMed

    Campagna, Raphael; Pessis, Eric; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc

    2013-02-01

    To evaluate the occurrence of coring after needle insertion through the rubber stopper of prednisolone acetate vials. Two-hundred vials of prednisolone acetate were randomly distributed to two radiologists. Prednisolone acetate was drawn up through the rubber bung of the vials with an 18-gauge cutting bevelled needle and aspirated with a 5-ml syringe. The presence of coring was noted visually. We systematically put each core in a syringe refilled with 3 ml prednisolone acetate, and injected the medication through a 20-gauge spine needle. Computed tomography was performed to measure the size of each coring. Coring occurred in 21 out of 200 samples (10.5 %), and was visually detected in the syringe filled up with prednisolone in 11 of the 21 cases. Ten more occult cores were detected only after the syringes and needles were taken apart and rinsed. The core size ranged from 0.6 to 1.1 mm, and 1 of the 21 (4.7 %) cores was ejected through the 20-gauge needle. Coring can occur after the insertion of a needle through the rubber stopper of a vial of prednisolone acetate, and the resultant core can then be aspirated into the syringe.

  8. InfuShield: a shielded enclosure for administering therapeutic radioisotope treatments using standard syringe pumps

    PubMed Central

    Pratt, Brenda E.; Chittenden, Sarah J.; Murray, Iain S.; Causer, Louise; Grey, Matthew J.; Gear, Jonathan I.; Du, Yong; Flux, Glenn D.

    2017-01-01

    The administration of radionuclide therapies presents significant radiation protection challenges. The aim of this work was to develop a delivery system for intravenous radioisotope therapies to substantially moderate radiation exposures to staff and operators. A novel device (InfuShield) was designed and tested before being used clinically. The device consists of a shielded enclosure which contains the therapeutic activity and, through the hydraulic action of back-to-back syringes, allows the activity to be administered using a syringe pump external to the enclosure. This enables full access to the pump controls while simultaneously reducing dose to the operator. The system is suitable for use with all commercially available syringe pumps and does not require specific consumables, maximising both the flexibility and economy of the system. Dose rate measurements showed that at key stages in an 131I mIBG treatment procedure, InfuShield can reduce dose to operators by several orders of magnitude. Tests using typical syringes and infusion speeds show no significant alteration in administered flow rates (maximum of 1.2%). The InfuShield system provides a simple, safe and low cost method of radioisotope administration. PMID:28187040

  9. The Life Science Exchange: a case study of a sectoral and sub-sectoral knowledge exchange programme.

    PubMed

    Perkins, Brian Lee; Garlick, Rob; Wren, Jodie; Smart, Jon; Kennedy, Julie; Stephens, Phil; Tudor, Gwyn; Bisson, Jonathan; Ford, David V

    2016-04-27

    Local and national governments have implemented sector-specific policies to support economic development through innovation, entrepreneurship and knowledge exchange. Supported by the Welsh Government through the European Regional Development Fund, The Life Science Exchange® project was created with the aim to increase interaction between stakeholders, to develop more effective knowledge exchange mechanisms, and to stimulate the formation and maintenance of long-term collaborative relationships within the Welsh life sciences ecosystem. The Life Science Exchange allowed participants to interact with other stakeholder communities (clinical, academic, business, governmental), exchange perspectives and discover new opportunities. Six sub-sector focus groups comprising over 200 senior stakeholders from academia, industry, the Welsh Government and National Health Service were established. Over 18 months, each focus group provided input to inform healthcare innovation policy and knowledge mapping exercises of their respective sub-sectors. Collaborative projects identified during the focus groups and stakeholder engagement were further developed through sandpit events and bespoke support. Each sub-sector focus group produced a report outlining the significant strengths and opportunities in their respective areas of focus, made recommendations to overcome any 'system failures', and identified the stakeholder groups which needed to take action. A second outcome was a stakeholder-driven knowledge mapping exercise for each area of focus. Finally, the sandpit events and bespoke support resulted in participants generating more than £1.66 million in grant funding and inward investment. This article outlines four separate outcomes from the Life Science Exchange programme. The Life Science Exchange process has resulted in a multitude of collaborations, projects, inward investment opportunities and special interest group formations, in addition to securing over ten times its own costs in funding for Wales. The Life Science Exchange model is a simple and straightforward mechanism for a regional or national government to adapt and implement in order to improve innovation, skills, networks and knowledge exchange.

  10. [The development tendencies of infusion pumps/syringe pumps].

    PubMed

    Zhang, Peng; Wang, Shu-Yi; Yu, Chuan-Yi; Zhang, Min-Yan

    2009-07-01

    Through the investigation about the current infusion pumps, the development tendencies of the next generation infusion pumps/Syringe Pumps with regarding to human-factors, practicality and application under MRI (Magnetic resonance imaging) were put forward.

  11. 21 CFR 522.2662 - Xylazine.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intramuscularly, by hand syringe, or by syringe dart, in the heavy muscles of the croup or shoulder as follows: (A... procedures, for therapeutic medication for sedation and relief of pain following injury or surgery, and as a...

  12. Assessment of the Implementation of the Erasmus Programme in Turkey through the Experiences of Foreign Students Visiting Turkish HEI's

    ERIC Educational Resources Information Center

    Burçer, Sibel

    2015-01-01

    The aim of this paper is to study the implementation of the ERASMUS programme in Turkey from the perspective of the foreign exchange students. The author conducted a survey which included 112 respondents from 8 Turkish universities. In the survey, the respondents assessed the level of language competence, the existence or the lack of sufficient…

  13. Methods of Study in Soil Ecology, Proceedings of the Symposium Organized by Unesco and the International Biological Programme (Paris, France, November, 1967).

    ERIC Educational Resources Information Center

    Phillipson, J., Ed.

    Included are papers (in French or English, with summaries in the other language) presented at a UNESCO-International Biological Programme symposium in 1967. The symposium provided an opportunity for the exchange of information on recent advances in soil ecology, with particular emphasis on soil productivity. Papers on broader theoretical aspects…

  14. Bundling occupational safety with harm reduction information as a feasible method for improving police receptiveness to syringe access programs: evidence from three U.S. cities

    PubMed Central

    Davis, Corey S; Beletsky, Leo

    2009-01-01

    Introduction In light of overwhelming evidence that access to sterile injection equipment reduces incidence of injection-attributable bloodborne disease without encouraging drug use, many localities have authorized sterile syringe access programs (SAPs), including syringe exchange and pharmacy-based initiatives. Even where such interventions are clearly legal, many law enforcement officers are unaware of the public health benefits and legal status of these programs and may continue to treat the possession of injection equipment as illegal and program participation as a marker of illegal behavior. Law enforcement practice can impede SAP utilization and may increase the risk of needlestick injury (NSI) among law enforcement personnel. Many SAPs conduct little or no outreach to law enforcement, in part because they perceive law enforcement actors as unreceptive to health-promotion programs targeting drug users. Case description We report on a brief training intervention for law enforcement personnel designed to increase officer knowledge of and positive attitudes towards SAPs by bundling content that addresses officer concerns about infectious disease and occupational safety with information about the legality and public health benefits of these programs. Pilot trainings using this bundled curriculum were conducted with approximately 600 officers in three US cities. Discussion and evaluation Law enforcement officers were generally receptive to receiving information about SAPs through the bundled curriculum. The trainings led to better communication and collaboration between SAP and law enforcement personnel, providing a valuable platform for better harmonization of law enforcement and public health activities targeting injection drug users. Conclusion The experience in these three cities suggests that a harm reduction training curriculum that bundles strategies for increasing officer occupational safety with information about the legality and public health benefits of SAPs can be well received by law enforcement personnel and can lead to better communication and collaboration between law enforcement and harm reduction actors. Further study is indicated to assess whether such a bundled curriculum is effective in changing officer attitudes and beliefs and reducing health risks to officers and injection drug users, as well as broader benefits to the community at large. PMID:19602236

  15. HCV infection prevalence lower than expected among 18-40-year-old injection drug users in San Diego, CA.

    PubMed

    Garfein, Richard S; Rondinelli, Amanda; Barnes, Richard F W; Cuevas, Jazmine; Metzner, Mitcheal; Velasquez, Michele; Rodriguez, David; Reilly, Meredith; Xing, Jian; Teshale, Eyasu H

    2013-06-01

    San Diego, California shares the world's busiest land border crossing with Tijuana, Mexico-a city where 95 % of injection drug users (IDUs) test hepatitis C virus (HCV) antibody-positive. Yet, little is known about the prevalence and risk behaviors for HCV among IDUs in San Diego. In 2009-2010, 18-40-year-old IDUs in San Diego County completed a risk assessment interview and serologic testing for HCV and HIV infection. Recruitment involved respondent-driven sampling, venue-based sampling at a syringe exchange program, and convenience sampling. Correlates of HCV infection were identified by multivariable logistic regression. Among 510 current IDUs, 26.9 % (95 % CI 23.0-30.7 %) and 4.2 % (95 % CI 2.4-5.9 %) had been infected with HCV and HIV, respectively. Overall, median age was 28 years; 74 % were male; 60 % white and 29 % Hispanic; and 96 % were born in the U.S. Median years of injecting was 6; 41 % injected daily; 60 % injected heroin most often; 49 % receptively shared syringes and 68 % shared other injection paraphernalia; and only 22 % reported always using new syringes in the past 3 months. Two thirds had ever traveled to Mexico and 19 % injected in Mexico. HCV infection was independently associated with sharing injection paraphernalia (adjusted odds ratio [AOR] = 1.69) and SEP use (AOR = 2.17) in the previous 3 months, lifetime history of drug overdose (AOR = 2.66), and increased years of injecting (AOR = 2.82, all P values <0.05). Controlling for recruitment method did not alter results. HCV infection prevalence among IDUs in San Diego was modest compared to other US cities and much lower than Tijuana. Given that known individual-level HCV risk factors were common in San Diego, the city's lower HCV prevalence might be due to differences in social and structural factors between the cities.

  16. Reducing HIV infection among new injecting drug users in the China-Vietnam Cross Border Project.

    PubMed

    Des Jarlais, Don C; Kling, Ryan; Hammett, Theodore M; Ngu, Doan; Liu, Wei; Chen, Yi; Binh, Kieu Thanh; Friedmann, Patricia

    2007-12-01

    To assess an HIV prevention programme for injecting drug users (IDU) in the crossborder area between China and Vietnam. Serial cross-sectional surveys (0, 6, 12, 18, 24 and 36 months) of community-recruited current IDU. The project included peer educator outreach and the large-scale distribution of sterile injection equipment. Serial cross-sectional surveys with HIV testing of community recruited IDU were conducted at baseline (before implementation) and 6, 12, 18, 24 and 36 months post-baseline. HIV prevalence and estimated HIV incidence among new injectors (individuals injecting drugs for < 3 years) in each survey wave were the primary outcome measures. The percentages of new injectors among all subjects declined across each survey waves in both Ning Ming and Lang Son. HIV prevalence and estimated incidence fell by approximately half at the 24-month survey and by approximately three quarters at the 36-month survey in both areas (all P < 0.01). The implementation of large-scale outreach and syringe access programmes was followed by substantial reductions in HIV infection among new injectors, with no evidence of any increase in individuals beginning to inject drugs. This project may serve as a model for large-scale HIV prevention programming for IDU in China, Vietnam, and other developing/transitional countries.

  17. Prefilled syringes: An innovation in parenteral packaging

    PubMed Central

    Makwana, Sagar; Basu, Biswajit; Makasana, Yogita; Dharamsi, Abhay

    2011-01-01

    Parenteral administration of pharmaceutical products is one of the most popular methods used to produce quick onset of action and also 100% bioavailability. Main problem occurs with the parenteral drug delivery is lack of convenience, affordability, accuracy, sterility, safety etc. Such drawbacks with this delivery system makes it less preferable. Hence, all the disadvantages of these systems can be easily overcome by use of prefilled syringes. The objective of this review article is to provide information regarding prefilled syringes; it's method of preparation, direction to use, advantages, its future scope, and development. PMID:23071944

  18. High aspect ratio, remote controlled pumping assembly

    DOEpatents

    Brown, Steve B.; Milanovich, Fred P.

    1995-01-01

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  19. Randomized, community-based pharmacy intervention to expand services beyond sale of sterile syringes to injection drug users in pharmacies in New York City.

    PubMed

    Crawford, Natalie D; Amesty, Silvia; Rivera, Alexis V; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M

    2013-09-01

    Structural interventions may help reduce racial/ethnic disparities in HIV. In 2009 to 2011, we randomized pharmacies participating in a nonprescription syringe access program in minority communities to intervention (pharmacy enrolled and delivered HIV risk reduction information to injection drug users [IDUs]), primary control (pharmacy only enrolled IDUs), and secondary control (pharmacy did not engage IDUs). Intervention pharmacy staff reported more support for syringe sales than did control staff. An expanded pharmacy role in HIV risk reduction may be helpful.

  20. Change in attitudes and knowledge of problem drug use and harm reduction among a community cohort in Kabul, Afghanistan.

    PubMed

    Todd, C S; Stanekzai, M R; Nasir, A; Fiekert, K; Orr, M G; Strathdee, S A; Vlahov, D

    2016-06-15

    This pre-post evaluation aimed to measure changes in knowledge and attitudes towards drug users among community representatives in Kabul, Afghanistan, over a period of expansion of harm reduction and drug dependence programming. A convenience sample of 160 professionals aged 18+ years completed interview questionnaires in 2007 and 2009. Views endorsing programme quality and the provision of condoms, infection counselling/testing and needle/syringe distribution increased significantly over the 2-year period. In 13 of 38 statements, there was a substantial (> 10%) change in agreement level, most commonly among men and medical professionals. Attitudes concerning support of drug users remained largely positive, with substantial attitude changes in some subgroups of the population. Further community education through the media and a more cohesive government drug policy may be needed to strengthen community support for harm reduction/drug treatment in Afghanistan.

  1. Increasing Awareness about HIV Prevention among Young People Who Initiated Injection Drug Use in a Canadian Setting, 1988–2014

    PubMed Central

    Bahji, Anees; Wood, Evan; Ahamad, Keith; Dong, Huiru; DeBeck, Kora; Milloy, M-J; Kerr, Thomas; Hayashi, Kanna

    2015-01-01

    Background Globally, harm reduction interventions, including needle and syringe programs (NSPs), have been shown to reduce HIV risks among people who inject drugs (PWID). However, little is known about the impact of these efforts on the circumstances of first injection. Therefore, we sought to identify changes in the awareness about HIV prevention and syringe borrowing at the time of first injection drug use in Vancouver, Canada, during a period of NSP expansion. Methods Data were drawn from prospective cohorts of PWID in Vancouver, who initiated injecting between 1988 and 2014. Multivariable regression was used to assess changes in the awareness about HIV and NSPs and syringe borrowing behaviour at first injection against calendar year of first injection. Results Among 1,044 participants (36.9% female), at the time of first injection 73.9% reported having known syringe sharing was an HIV risk, 54.1% reported having heard of NSPs, and 7.8% reported having borrowed a syringe used by others. In multivariable analyses, calendar year of first injection was independently and positively associated with awareness about HIV (adjusted prevalence ratio [APR]: 1.09; 95% confidence interval [CI]: 1.06, 1.11) and awareness about NSPs (APR: 1.18; 95% CI: 1.13, 1.24). While calendar year of first injection was significantly and negatively associated with syringe borrowing at first injection in bivariable analyses, the association did not remain significant in multivariable analyses (adjusted odds ratio: 0.90; 95% CI: 0.72, 1.14). Conclusions We found that awareness about HIV and NSPs at first injection have increased over time amongst PWID in this setting. However, declining trends in syringe borrowing at first injection were not determined after adjustment for socio-demographic characteristics. This suggests that HIV prevention efforts may have contributed to increased awareness about HIV prevention, but further research is needed to identify sub-populations at heightened risk of HIV at first injection. PMID:26514080

  2. Impact of HIV Status Notification on Risk Behaviors among Men Who Inject Drugs in Kermanshah, West of Iran.

    PubMed

    Noroozi, Alireza; Mirzazadeh, Ali; Farhoudian, Ali; Hajebi, Ahmad; Khankeh, Hamid Reza; Higgs, Peter; Sharifi, Hamid; Armoon, Bahram; Noroozi, Mehdi

    2016-01-01

    It is unclear whether knowing of current HIV status is associated with change in injecting behaviors among people who inject drugs (PWID) in Iran. The objective of the present study was to determine whether awareness of HIV positive status is associated with a reduction in injecting risk behaviors, after matching for socio-demographic characteristics. Five hundred male PWID were recruited in 2014 from two drop-in centers (DICs) in Kermanshah west of Iran. Trained interviewers collected data on socio-demographic characteristics, HIV testing and drug-related risk behaviors over the last month prior to interview using a structured questionnaire. Our primary exposure of interest was awareness of HIV status, used to group participants into three categories: positive, negative, unaware. We used coarsened exact matching to make the three groups statistically equivalent based on age, place of residence, education and income, and then compared them regarding the proportion of borrowing, lending and reuse of syringes. Matched sample (n=320) had a mean age ± standard deviation (SD) of 33.5 ±7.6 yr. Overall, 25% (95% CI: 14%, 32%) of participants reported "borrowing a syringe" in the past month and 15% (95% CI: 7%, 22%) of them reported "lending a used syringe" to others in the past month. In comparison to PWID who were unaware of their HIV status, those knew they were HIV positive (OR 1.68, CI95%1.32-2.81) or negative (OR 1.54; 95% CI: 1.28, 2.71) were both more likely to report borrowing syringes in past month. PWID WHO know they are positive for HIV are more likely to borrow another person's syringe, to report reuse of their own used syringes and less likely to report lending their syringes to others. Strategies to scale up HIV testing and counseling for PWID, which also increase awareness of HIV status, may decrease injecting related the risk behaviors.

  3. A global health partnership's use of time-limited support to catalyze health practice change: the case of GAVI's Injection Safety Support.

    PubMed

    Levin, Ann; Fang, Arnold; Hansen, Peter M; Pyle, David; Dia, Ousmane; Schwalbe, Nina

    2010-09-27

    This paper presents the findings of a study to assess the effectiveness and sustainability of a GAVI (Global Alliance of Vaccines and Immunization) sponsored, time-limited Injection Safety (INS) support. The support came in two forms: 1) in-kind, in the form of AD syringes and safety boxes, and 2) in cash, for those countries that already had a secure, multi-year source of AD syringes and safety boxes, but proposed to use INS support to strengthen their injection safety activities. In total, GAVI gave INS support for a three-year period to 58 countries: 46 with commodities and 12 with cash support. To identify variables that might be associated with financial sustainability, frequencies and cross-tabulations were run against various programmatic and socio-economic variables in the 58 countries. All but two of the 46 commodity-recipient countries were able to replace and sustain the use of AD syringes and safety boxes after the end of their GAVI INS support despite the fact that standard disposable syringes are less costly than ADs (10-15 percent differential). In addition, all 12 cash-recipient countries continued to use AD syringes and safety boxes in their immunization programs in the years following GAVI INS assistance. At the same time, countries were often not prepared for the increased waste management requirements associated with the use of the syringes, suggesting the importance of anticipating challenges with the introduction of new technologies. The sustained use of AD syringes in countries receiving injection safety support from GAVI, in a majority of cases through government financing, following the completion of three years of time-limited support, represents an early indication of how GHPs can contribute to improved health outcomes in immunization safety in the world's poorest countries in a sustainable way.

  4. Effects of Different Containers on Radioactivity Measurements using a Dose Calibrator with Special Reference to 111In and 123I.

    PubMed

    Inoue, Yusuke; Abe, Yutaka; Kikuchi, Kei; Miyatake, Hiroki; Watanabe, Atsushi

    2017-01-01

    Low-energy characteristic x-rays emitted by 111 In and 123 I sources are easily absorbed by the containers of the sources, affecting radioactivity measurements using a dose calibrator. We examined the effects of different containers on the estimated activities. The radioactivities of 111 In, 123 I, 201 Tl, and 99m Tc were measured in containers frequently employed in clinical practice in Japan. The 111 In measurements were performed in the vials A and B of the 111 In-pentetreotide preparation kit and in the plastic syringe. The activities of 123 I-metaiodobenzylguanidine and 201 Tl chloride were measured in the prefilled glass syringes and plastic syringes. The milking vial, vial A, vial B, and plastic syringe were used to assay 99m Tc. For 111 In and 123 I, measurements were performed with and without a copper filter. The filter was inserted into the well of the dose calibrator to absorb low-energy x-rays. The relative estimate was defined as the ratio of the activity estimated with the dose calibrator to the standard activity. The estimated activities varied greatly depending on the container when 111 In and 123 I sources were assayed without the copper filter. The relative estimates of 111 In were 0.908, 1.072, and 1.373 in the vial A, vial B, and plastic syringe, respectively. The relative estimates of 123 I were 1.052 and 1.352 in the glass syringe and plastic syringe, respectively. Use of the copper filter eliminated the container-dependence in 111 In and 123 I measurements. Container-dependence was demonstrated in neither 201 Tl nor 99m Tc measurements. The activities of 111 In and 123 I estimated with a dose calibrator differ greatly among the containers. Accurate estimation may be attained using the container-specific correction factor or using the copper filter.

  5. Stability of Dalteparin 1,000 Unit/mL in 0.9% Sodium Chloride for Injection in Polypropylene Syringes.

    PubMed

    Kirkham, Kylian; Munson, Jessica M; McCluskey, Susan V; Graner, Kevin K

    2017-01-01

    The stability of dalteparin 1,000 units/mL in 0.9% sodium chloride for injection stored in polypropylene syringes under refrigeration was examined. Dalteparin 1,000-units/mL syringes were prepared by adding 9 mL of 0.9% sodium chloride for injection to 1 mL of dalteparin sodium 10,000 unit/mL from commercial single-use syringes. Compounded solutions in 0.5-mL aliquots were transferred to 1-mL polypropylene syringes and sealed with a Luer lock tip cap and stored at refrigerated temperatures (2°C to 8°C) with ambient fluorescent light exposure. Syringes from three batches of dalteparin 1,000 units/mL were potency tested in duplicate by a stability-indicating high-performance liquid chromatography assay using a 0.5-mL sample at specified intervals. Visual and pH testing were performed on each batch. Samples were visually inspected for container integrity, color, and clarity. Samples for pH testing were prepared using a 1:1 dilution of dalteparin 1,000 units/mL in sterile water for injection and underwent duplicate analysis at each time point. High-performance liquid chromatography analyses showed a remaining percent of the initial dalteparin content at day 30 of 94.88% ± 2.11%. Samples remained colorless and clear with no signs of container compromise and no visual particulate matter at each time point. Throughout the 30-day study period, pH values remained within 0.3-pH units from the initial value of 5.84. Dalteparin 1,000 unit/mL in 0.9% sodium chloride for injection, packaged in 1-mL polypropylene syringes was stable for at least 30 days while stored at refrigerated conditions with ambient fluorescent light exposure. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  6. Particulate and microbial contamination in in-use admixed intravenous infusions.

    PubMed

    Yorioka, Katsuhiro; Oie, Shigeharu; Oomaki, Masafumi; Imamura, Akihisa; Kamiya, Akira

    2006-11-01

    We compared particulate and microbial contamination in residual solutions of peripheral intravenous admixtures after the termination of drip infusion between intravenous fluids admixed with glass ampoule drugs and those admixed with pre-filled syringe drugs. The mean number of particles>or=1.3 microm in diameter per 1 ml of residual solution was 758.4 for fluids (n=60) admixed with potassium chloride in a glass ampoule (20 ml volume), 158.6 for fluids (n=63) admixed with potassium chloride in a pre-filled syringe (20 ml volume), 736.5 for fluids (n=66) admixed with sodium chloride in a glass ampoule (20 ml volume), 179.2 for fluids (n=15) admixed with sodium chloride in a pre-filled syringe (20 ml volume), 1884.5 in fluids (n=30) admixed with dobutamine hydrochloride in 3 glass ampoules (5 ml volume), and 178.9 (n=10) in diluted dobutamine hydrochloride in pre-filled syringes (50 ml volume: For these samples alone, particulate and microbial contamination were evaluated in sealed products.) Thus, for potassium chloride or sodium chloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was significantly higher for fluids admixed with glass ampoule drugs than for those admixed with pre-filled syringe drugs (p<0.0001). For dobutamine hydrochloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was estimated to be higher for fluids admixed with its glass ampoule drug than for those admixed with its pre-filled syringe drug. Observation of the residual solutions of fluids admixed with potassium chloride, sodium chloride, or dobutamine hydrochloride in glass ampoules using an electron microscope with an X-ray analyzer showed glass fragments in each residual solution. Therefore, for the prevention of glass particle contamination in peripheral intravenous admixtures, the use of pre-filled syringe drugs may a useful method. No microbial contamination was observed in any of the residual solutions of 5 types of admixture.

  7. Effects of police confiscation of illicit drugs and syringes among injection drug users in Vancouver.

    PubMed

    Werb, Daniel; Wood, Evan; Small, Will; Strathdee, Steffanie; Li, Kathy; Montaner, Julio; Kerr, Thomas

    2008-08-01

    Drug market policing has been associated with various harms among injection drug users (IDU). However, little is known about instances in which drugs and injecting equipment are confiscated from IDU in the absence of a formal arrest. We examined factors associated with being stopped, searched, or detained by police among participants in the Vancouver Injection Drug Users Study (VIDUS) using logistic regression. We also examined actions taken by study participants immediately following instances in which drugs or syringes were confiscated by police. Among 465 active IDU, 130 (28.0%) reported being detained by police in the last 6 months without being arrested. In multivariate logistic regression analysis, factors associated with being stopped, searched or detained by police included homelessness (Adjusted Odds Ratio [AOR]=3.96, 95% CI: 1.86-8.45), recent incarceration (AOR=3.52, 95% CI: 1.75-7.10), frequent crack use (AOR=2.24, 95% CI: 1.34-3.74), requiring help injecting (AOR=5.20, 95% CI: 1.21-22.39), and lending syringes (AOR=3.18, 95% CI: 1.09-9.30). Of those who reported being detained, 34% participants reported having had drugs confiscated, and 70% of these reported that they immediately acquired more drugs. Fifty-one percent of participants who reported being detained also reported having had syringes confiscated, and of this group, 6% reported immediately borrowing used syringes. Our study demonstrates that the IDU most affected by street-level policing tend to possess various characteristics, such as homelessness, that place them at heightened risk for various adverse health outcomes. Our findings also suggest that the confiscation of drugs and/or needles and syringes through discretionary policing practices have the potential to exacerbate drug market activity or prompt increased syringe borrowing. These findings indicate the need for ongoing evaluation of the public health impacts of discretionary policing approaches.

  8. Experiments with Disposable Hypodermic Syringes.

    ERIC Educational Resources Information Center

    Clayton, G. T.; And Others

    1988-01-01

    Lists five experiments or demonstrations involving hypodermic syringes. The titles of experiments are Boyle's Law, Charles' Law, Atmospheric Pressure, Expansion of Gases, and Boiling at Reduced Pressure. Provides a list of materials, the typical data, and graphs where appropriate. (YP)

  9. The compatibility and stability of midazolam and dexamethasone in infusion solutions.

    PubMed

    Good, Phillip D; Schneider, Jennifer J; Ravenscroft, Peter J

    2004-05-01

    The delivery of subcutaneous medication by continuous infusion is common in palliative medicine. Many centers combine multiple medications, but the analytical confirmation of the compatibility and stability of these combinations has rarely been performed. This study examined the compatibility and stability of midazolam and dexamethasone using high performance liquid chromatography. Nine different solutions were prepared in polypropylene syringes by combining these two drugs with 0.9% sodium chloride. When these two drugs were combined in a syringe, there was significant loss of midazolam over 48 hours, with only 60-80% of the initial concentration remaining in syringes stored at 35-39 degrees C. This study demonstrates that cloudiness of a solution is not the only predictor of drug loss and that drug loss may occur even in solutions that remain clear at time of preparation. The clinical implications of these results are that dexamethasone and midazolam should not be combined in syringe driver solutions.

  10. Disintegration of chemotherapy tablets for oral administration in patients with swallowing difficulties.

    PubMed

    Siden, Rivka; Wolf, Matthew

    2013-06-01

    The administration of oral chemotherapeutic drugs can be problematic in patients with swallowing difficulties. Inability to swallow solid dosage forms can compromise compliance and may lead to poor clinical outcome. The current technique of tablet crushing to aid in administration is considered an unsafe practice. By developing a technique to disintegrate tablets in an oral syringe, the risk associated with tablet crushing can be avoided. The purpose of this study was to determine the feasibility of using disintegration in an oral syringe for the administration of oral chemotherapeutic tablets. Eight commonly used oral chemotherapeutic drugs were tested. Tablets were placed in an oral syringe and allowed to disintegrate in tap water. Various volumes and temperatures were tested to identify which combination allows for complete disintegration of the tablet in the shortest amount of time. The oral syringe disintegration method was considered feasible if disintegration occurred in ≤15 min and in ≤20 mL of water and the dispersion passed through an oral syringe tip. The following tablets were shown to disintegrate within 15 min and in <20 mL of water: busulfan, cyclophosphamide 50 mg, dasatinib, imatinib, methotrexate, and thioguanine. For these drugs, drug-specific information pamphlets can be prepared for patient or caregiver use. Mercaptopurine, cyclophosphamide 25 mg, and mitotane tablets did not pass the disintegration test. Disintegrating oral chemotherapeutic tablets in a syringe provides a closed system to administer hazardous drugs and allows for the safe administration of oral chemotherapeutic drugs in a tablet form to patients with swallowing difficulties.

  11. [Aseptic non-touch technique in the operating room: keep it simple].

    PubMed

    Pans, Solange J A; Molmans, Eva; Marczinski, Susanne C; Bijker, Jilles B; Snijdelaar, Dik G

    2015-01-01

    The Dutch national patient safety platform developed a protocol for the preparation of intravenous medication; the Aseptic Non-Touch Technique (ANTT). Use of ANTT on nursing wards has shown to reduce contamination of intravenous medication. Therefore it is dictated by the Dutch Healthcare Inspectorate that this technique has to be used at all departments in the hospital, including the operating theatre. However, because of the use of air treatment and operating theatre uniforms, the operating theatre cannot be compared with a nursing ward. In this study, the bacterial contamination of syringes prepared in the operating theatre by anesthesia nurses was determined. Simulation study 45 anesthesia nurses prepared 1000 syringes of 10 ml bacterial culture medium, using their routine method of drawing up iv medication from vials. Turbidity in a syringe after culturing for 14 days at 30° C was used as evidence for bacterial contamination. Using questionnaires, nurses were interviewed in what degree their working method equals ANTT-protocol. We calculated how much extra time must be invested when using the strict ANTT-protocol in the operating theatre. Six syringes (0,6%) were contaminated. Normal dermal bacteria were identified in all syringes. The nurses who prepared the contaminated syringes worked similar manner as their colleagues. It takes an additional 54 minutes per day per operating theatre to work strictly using the ANTT technique. Contamination rates of aseptic preparations in the OR are very low, and are as low as ANTT preparations in a GMP-certified hospital pharmacy. Therefore it is legitimate to develop a modified ANTT-protocol for use in the operating theatre.

  12. Evaluation of the use of a needle-free injection syringe as a cause of non-specific reactions in the intradermal tuberculin test used for the diagnosis of bovine tuberculosis.

    PubMed

    Díez-Guerrier, A; Roy, A; de la Cruz, M L; Sáez, J L; Sanz, C; Boschiroli, M L; Romero, B; de Juan, L; Domínguez, L; Bezos, J

    2018-05-24

    The objective of the study was to elucidate whether the use of the needle-free Dermojet syringe, which is based on a high pressure inoculation and is used to inject tuberculin in cattle in several countries, may, in itself, cause skin reactions that can be interpreted as positive reactions to the intradermal tests that are not, in fact, related to the real infection status of the animals. Forty-four cattle from an officially tuberculosis-free (OTF) herd were selected, and four single intradermal tuberculin (SIT) tests were performed on each animal, two on each side of the neck. Three different Dermojet (D1, D2 and D3) and one McLintock (M4) syringes were used to carry out sterile phosphate buffer saline (PBS) with 10% of glycerol and bovine PPD injections. No positive reactions to the SIT test were observed when using the D1-D3 syringes in the case of either bovine PPD or PBS. With regard to M4 (PBS), all the tests were negative when using a standard interpretation but three were positive in the case of the severe interpretation. Significant differences (p < 0.05) in the skin fold thickness measured were found only between certain Dermojet and McLintock syringes at certain inoculation sites. The results showed that the needle-free Dermojet syringe used for PPD intradermal testing in cattle did not cause significant reactions that could be misunderstood as positives. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Development of a group-based self-management programme for individuals with chronic fatigue syndrome: a pilot study.

    PubMed

    Pinxsterhuis, Irma; Hellum, Live Lange; Aannestad, Hilde Hassum; Sveen, Unni

    2015-03-01

    The aim of the study was to develop a group-based self-management programme for individuals with chronic fatigue syndrome (CFS) by using the participants' experiences with the initial version of the programme, which intends to promote coping with the illness in a primary healthcare setting. An initial programme was developed, based on self-efficacy theory and the concepts of client-centred practice and empowerment. Subsequently, the programme was tested and further developed by drawing on the participants' experiences with the programme. Focus-group interviews were applied. The interviews were analysed using thematic analysis. The initial programme was found to be feasible, although several modifications regarding the content and practical organization of the programme were proposed. In line with the participants' experiences, the final self-management programme was developed, which includes short presentations of eight topics, exchange of experiences among participants, goal-setting, construction of action plans, and relaxation exercises, in addition to a meeting for relatives. The programme will be provided in eight biweekly sessions and be led by juxtaposed peer counsellors and occupational therapists. The effects of the final programme will be evaluated in a randomized controlled trial.

  14. Prevalence and correlates of HIV infection among men who inject drugs in a remote area of Vietnam.

    PubMed

    Nghiem, Van T; Bui, Thanh C; Nadol, Patrick P; Phan, Son H; Kieu, Binh T; Kling, Ryan; Hammett, Theodore M

    2018-02-14

    Lack of information on the HIV epidemic among men who inject drugs (MWID) in northwestern Vietnam, a remote area, may hamper national efforts to control the disease. We examined HIV prevalence, needle-syringe sharing behaviors, and associated factors among MWID in three areas of northwestern Vietnam. We used descriptive analysis to report the characteristics, frequency of risk behaviors, and of access to healthcare services among the MWID. Univariable logistic regression was used to assess the associations between the HIV infection, needle-syringe sharing behaviors, and their independent variables. We further explored these associations in multivariable analyses where we included independent variables based on a priori knowledge and their associations with the dependent variables determined in univariable analyses (p <  0.25). The HIV prevalence was 37.9, 16.9, and 18.5% for Tuan Giao, Bat Xat, and Lao Cai City, respectively, and 25.4% overall. MWID of Thai minority ethnicity were more likely to be HIV-positive (adjusted odds ratio (AOR) 3.55; 95% confidence interval (CI) 1.84-6.87). The rate of needle-syringe sharing in the previous 6 months was approximately 9% among the MWID in Tuan Giao and Lao Cai City, and 27.8% in Bat Xat. Two thirds of the participants never underwent HIV testing before this study. Ever having been tested for HIV before this study was not associated with any needle-syringe sharing behaviors. Among the HIV-positive MWID, those who received free clean needles and syringes were less likely to give used needles and syringes to peers (AOR 0.21; 95% CI 0.06-0.79). Going to a "hotspot" in the previous week was associated with increased odds of needle-syringe sharing in multiple subgroups. Our findings on HIV prevalence and testing participation among a subset of MWID in the northwestern Vietnam were corroborated with trend analysis results from the most recent HIV/STI Integrated Biological and Behavioral Surveillance report (data last collected in 2013.) We provided important insights into these MWID's risky injection behaviors. We suggest heightened emphasis on HIV testing and needle and syringe provision for this population. Also, policymakers and program implementers should target hotspots as a main venue to tackle HIV epidemics.

  15. The impact of international placements on nurses' personal and professional lives: literature review.

    PubMed

    Button, Lori; Green, Barbara; Tengnah, Cassam; Johansson, Inez; Baker, Christine

    2005-05-01

    This paper presents a critical review of research literature on the impact of international placements on the lives and practice of nurses. Health care institutions are progressively more aware of the need to respond to diverse patient populations and cultivate leaders to enrich the nursing profession, both locally and globally. One response has been to establish international exchange programmes for nursing students to give them experience of different cultures and health care systems. A search of the literature from 1980 to 2003 using electronic databases was undertaken using the databases CINAHL, ERIC, British Nursing Index, Web of Science, the BIDS Social Science Citation Index and Medline. The keywords used were 'international exchange experience', 'international studies', 'international education', 'international placement(s)', 'exchange programme(s)', combined with 'nurses/nursing', combined with 'evaluation', 'practice', 'education' and/or 'policy'. The papers retrieved used both qualitative and quantitative approaches and were scrutinized for recurring themes. Nurses reported significant changes in their personal development, perspectives on nursing practice and critical appraisal of health care systems. They also indicated an increased appreciation and sensitivity towards cultural issues and cross-cultural care. Moreover, differences in placement programmes, such as duration, preparation and debriefing were found to have affected the reported overall international placement experience. However, the primary effects of international placements were identified as personal development and transcultural adaptation. Students should be exposed to a variety of nursing experiences within the host country. This would give them a broad spectrum for comparisons between cultures, nursing practice and health care delivery in those cultures. Therefore, educational institutions are strongly encouraged to provide opportunities for students to participate in nursing care and education in another country.

  16. Comparing the Development of Transversal Skills between Virtual and Physical Exchanges

    ERIC Educational Resources Information Center

    Van der Velden, Bart; Millner, Sophie; Van der Heijden, Casper

    2016-01-01

    This paper aims to compare the impact on the development of transversal skills, such as self-esteem, of virtual and physical exchanges. This is done by comparing the Europe on the Edge programme to the results of the Erasmus Impact Study. In doing so it fills the need that has been expressed in the telecollaboration field to study the impact of…

  17. Short-Term Study Tours as a Driver for Increasing Domestic Student Mobility in Order to Generate Global Work-Ready Students and Cultural Exchange in Asia Pacific

    ERIC Educational Resources Information Center

    Scharoun, Lisa

    2016-01-01

    Recent federal government programmes in Australia have seen a shift in focus from the international student towards increasing the possibilities for domestic mobility through short- and long-term exchange opportunities. The current New Colombo Plan funding scheme encourages Australian students, who have traditionally undertaken semester-long…

  18. Solubility and Stability of Baclofen 3 mg/mL Intrathecal Formulation and Its Compatibility With Implantable Programmable Intrathecal Infusion Systems.

    PubMed

    Yue, Baohua; Brendel, Ron; Lukitsch, Amelia; Prentice, Thomas; Doty, Brian

    2017-06-01

    Commercial baclofen formulations used with infusion pumps are available at therapeutic concentrations of 0.5-2.0 mg/mL. However, patients who receive higher daily doses of baclofen may benefit from products with greater baclofen concentrations since their refill frequency would be reduced (up to a maximum of 180 days). We evaluated baclofen solubility, baclofen 3 mg/mL intrathecal (IT) formulation stability, and chemical and physical compatibility with Medtronic SynchroMed ® II and Codman Medstream ® programmable IT infusion pumps. For solubility evaluations, baclofen powder was dissolved into isotonic saline and tested at 5°C, 25°C, and 40°C. To demonstrate drug product stability, both physical and chemical stability attributes of baclofen 3 mg/mL in prefilled syringes were evaluated over 36 months with storage at 25°C. For a simulated in-use stability (compatibility) study, a 3 mg/mL baclofen IT formulation was placed in SynchroMed II and Codman Medstream pumps at 37ºC for study durations, and evaluated at different flow rates. Pump effluent was collected at various times and analyzed by high-performance liquid chromatography for baclofen content. On completion of the in-use stability study, pumps exposed to baclofen 3 mg/mL were dissected and visually evaluated for signs of deterioration. Baclofen solubility was found to be 3.2 mg/mL at 5°C, 3.6 mg/mL at 25°C, and 3.9 mg/mL at 40°C. During the 36-month stability study of prefilled syringes stored at 25°C, baclofen content remained unchanged and no precipitation was observed. The simulated in-use pump study performed at 37ºC showed that a baclofen 3 mg/mL IT formulation was stable at different flow rates and throughout different expected residence times for both pump models. Components from both pumps exhibited no noticeable deterioration after exposure to the 3 mg/mL formulation. Baclofen 3 mg/mL IT formulation was stable during long-term storage at 25°C and remained stable under conditions matching those encountered in clinical practice (37°C). © 2016 International Neuromodulation Society.

  19. Randomized, Community-Based Pharmacy Intervention to Expand Services Beyond Sale of Sterile Syringes to Injection Drug Users in Pharmacies in New York City

    PubMed Central

    Amesty, Silvia; Rivera, Alexis V.; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M.

    2013-01-01

    Structural interventions may help reduce racial/ethnic disparities in HIV. In 2009 to 2011, we randomized pharmacies participating in a nonprescription syringe access program in minority communities to intervention (pharmacy enrolled and delivered HIV risk reduction information to injection drug users [IDUs]), primary control (pharmacy only enrolled IDUs), and secondary control (pharmacy did not engage IDUs). Intervention pharmacy staff reported more support for syringe sales than did control staff. An expanded pharmacy role in HIV risk reduction may be helpful. PMID:23865644

  20. High aspect ratio, remote controlled pumping assembly

    DOEpatents

    Brown, S.B.; Milanovich, F.P.

    1995-11-14

    A miniature dual syringe-type pump assembly is described which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor. 4 figs.

  1. Subcutaneous drug infusions: a review of problems and solutions.

    PubMed

    Mitten, T

    2001-02-01

    Subcutaneous drug infusion using a portable syringe driver has had a significant impact on patient comfort in palliative care. It permits the continuous delivery of a range of drug therapies, so bypassing problems of dysphagia, weakness and the inability of many patients in the terminal phase to take oral medication. The devices are not problem-free, however. Mechanical problems, reactions at the infusion site and difficulties with the mixing of drugs in the syringe are all widely recognized. This article reviews some general issues with the operation of portable syringe drivers, and discusses a range of potential problems and their solutions.

  2. Automated fluid analysis apparatus and techniques

    DOEpatents

    Szecsody, James E.

    2004-03-16

    An automated device that couples a pair of differently sized sample loops with a syringe pump and a source of degassed water. A fluid sample is mounted at an inlet port and delivered to the sample loops. A selected sample from the sample loops is diluted in the syringe pump with the degassed water and fed to a flow through detector for analysis. The sample inlet is also directly connected to the syringe pump to selectively perform analysis without dilution. The device is airtight and used to detect oxygen-sensitive species, such as dithionite in groundwater following a remedial injection to treat soil contamination.

  3. Biopharmaceutical formulations for pre-filled delivery devices.

    PubMed

    Jezek, Jan; Darton, Nicholas J; Derham, Barry K; Royle, Nikki; Simpson, Iain

    2013-06-01

    Pre-filled syringes are becoming an increasingly popular format for delivering biotherapeutics conveniently and cost effectively. The device design and stable liquid formulations required to enable this pre-filled syringe format are technically challenging. In choosing the materials and process conditions to fabricate the syringe unit, their compatibility with the biotherapeutic needs to be carefully assessed. The biothereaputic stability demanded for the production of syringe-compatible low-viscosity liquid solutions requires critical excipient choices to be made. The purpose of this review is to discuss key issues related to the stability aspects of biotherapeutics in pre-filled devices. This includes effects on both physical and chemical stability due to a number of stress conditions the product is subjected to, as well as interactions with the packaging system. Particular attention is paid to the control of stability by formulation. We anticipate that there will be a significant move towards polymer primary packaging for most drugs in the longer term. The timescales for this will depend on a number of factors and hence will be hard to predict. Formulation will play a critical role in developing successful products in the pre-filled syringe format, particularly with the trend towards concentrated biotherapeutics. Development of novel, smart formulation technologies will, therefore, be increasingly important.

  4. Measurements of occupational exposure for a technologist performing 18F FDG PET scans.

    PubMed

    Biran, Talma; Weininger, Jolie; Malchi, Shalom; Marciano, Rami; Chisin, Roland

    2004-11-01

    Radiation doses to one PET technologist performing 100 18F FDG (18F fluorodeoxyglucose) imaging procedures were measured in a clinical setting using two types of thermoluminescent dosimeter (TLD) badges, one finger-ring TLD and one electronic pocket dosimeter (EPD). 18F FDG was handled either with unshielded or with viewing window tungsten shielded syringes. The resulting doses using unshielded syringes were 13.8 +/- 0.8 microSv/370 MBq and 14.3 +/- 0.4 microSv/370 MBq, measured with TLD 100 and with TLD 700H/600H, respectively. For the same series of measurements, the doses obtained using shielded syringes were 10.7 +/- 0.4 microSv/370 MBq and 7.2 +/- 2.1 microSv/370 MBq with TLD700H/600H and with EPD, respectively. The dose to the right hand from shielded syringes was 69.3 +/- 5.5 microSv/370 MBq. All these values are within the ICRP recommended dose limits. Extrapolated to 725 examinations per year, the resulting effective dose measured with TLD would be 10 mSv with unshielded and 7.5 mSv with shielded syringes, respectively (25% dose reduction). The doses measured by TLD were consistently higher than those measured by EPD, suggesting that EPD measurements might underestimate occupational doses.

  5. Effects of mobile phone use on specific intensive care unit devices.

    PubMed

    Hans, Nidhi; Kapadia, Farhad N

    2008-10-01

    To observe the effects of mobile phone use in the vicinity of medical devices used in a critical care setting. Electromagnetic interference (EMI) was tested by using two types of mobile phones - GSM and CDMA. Mobile phones were placed at a distance of one foot from three medical devices - syringe pump, mechanical ventilator, and the bedside monitor - in switch off, standby, and talking modes of the phone. Medical devices were observed for any interference caused by the electromagnetic radiations (EMR) from the mobile phones. Out of the three medical devices that were tested, EMI occurred while using the mobile phone in the vicinity of the syringe pump, in the 'talk mode.' The mean variation observed in the calculated and delivered volume of the syringe pump was 2.66 ml. Mechanical ventilator did not show any specific adverse effects with mobile phone use in the one-foot vicinity. No other adverse effects or unexplained malfunctions or shutdown of the syringe pump, mechanical ventilator, or the bedside monitor was noted during the study period of 36 hours. EMI from mobile phones have an adverse effect on the medical devices used in critical care setup. They should be used at least one foot away from the diameter of the syringe pump.

  6. Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.

    PubMed

    Mushtaq, Ahmad; Ur Rehman, Taj; Safdar Mansur, Muhammad; Jehangir, Mustanser

    2008-06-01

    Many groups have reported the adsorption or retention of (99m)Tc-radiopharmaceuticals on injection vials and disposable plastic syringes. Such an enormously high loss of radioactivity would result in poor images, radiation exposure, waste, and economic burdens. We therefore decided to investigate the extent of adsorption or retention of several (99m)Tc-radiopharmaceuticals on injection vials, rubber stoppers, and plastic syringes. These radiopharmaceuticals are produced as lyophilized kits in our department and supplied to various hospitals practicing nuclear medicine in Pakistan. A vial containing lyophilized material was reconstituted with 3 mL of freshly eluted Na(99m)TcO(4). A 1-mL aliquot of the resulting solution was withdrawn into a syringe at 0.25, 0.5, 1, 3, and 5 h after preparation. All preparations were stored at room temperature ( approximately 22 degrees C). After each withdrawal, the vial was reweighed and the activity remaining in the vial was measured using a radioisotope calibrator. The sample was reinjected into the vial. From the original weight and activity of solution in the vial, the initial activity per gram was calculated. From the weight and activity remaining in the vial after withdrawal of the sample, the activity per gram of the sample was calculated. From the difference between the initial activity per gram and the activity per gram of the sample, the percentage of (99m)Tc adsorbed on the vial was calculated. All preparations were kept in the syringe for 15 min, and the activity was measured before and after the syringe was emptied. The needle and plunger of the syringe were separated, and activity in the needle and plunger was also measured. The labeling efficiency of all radiopharmaceuticals used during these studies was more than 95%. In most cases, the activity of (99m)Tc found on the rubber stopper was less than 1%. Adsorption of (99m)Tc onto vials increased gradually with storage time. Adsorption was minimal at the initial stages, whereas maximum retention was noted after 5 h. Nearly 5% adsorption of activity was observed after 5 h of storage time on vials of sestamibi, mercaptoacetyltriglycine, dextran, ciprofloxacin, and dimercaptosuccinic acid (III and V). Retention of activity on needles ranged from 1% to 2% for all preparations studied. Plungers did not show any significant retention of radioactivity; in most cases, retention was less than 0.5%. The maximum retention of radioactivity on plastic syringe bodies was more than 3% for sestamibi, dimercaptosuccinic acid, dextran, pyrophosphate, and phytate. The results revealed that losses of radioactivity from (99m)Tc-radiopharmaceuticals in these objects (glass vial, rubber stopper, plastic syringes, plungers, and needles) are not alarming in our setup.

  7. Police Encounters Among Needle Exchange Clients in Baltimore: Drug Law Enforcement as a Structural Determinant of Health.

    PubMed

    Beletsky, Leo; Cochrane, Jess; Sawyer, Anne L; Serio-Chapman, Chris; Smelyanskaya, Marina; Han, Jennifer; Robinowitz, Natanya; Sherman, Susan G

    2015-09-01

    We piloted a monitoring mechanism to document police encounters around programs targeting people who inject drugs (PWID), and assessed their demographic predictors at 2 Baltimore, Maryland, needle exchange program (NEP) sites. In a brief survey, 308 clients quantified, characterized, and sited recent police encounters. Multivariate linear regression determined encounter predictors, and we used geocoordinate maps to illustrate clusters. Within the past 6 months, clients reported a median of 3 stops near NEP sites (interquartile range [IQR] = 0-7.5) and a median of 1 arrest in any location (IQR = 0-2). Three respondents reported police referral to the NEP. Being younger (P = .009), being male (P = .033), and making frequent NEP visits (P = .02) were associated with reported police stops. Among clients reporting arrest or citation for syringe possession, Whites were significantly less likely than non-Whites to report being en route to or from an NEP (P < .001). Reported encounters were clustered around NEPs. Systematic surveillance of structural determinants of health for PWID proved feasible when integrated into service activities. Improved monitoring is critical to informing interventions to align policing with public health, especially among groups subject to disproportionate levels of drug law enforcement.

  8. The increased incidence of pure red cell aplasia with an Eprex formulation in uncoated rubber stopper syringes.

    PubMed

    Boven, Katia; Stryker, Scott; Knight, John; Thomas, Adrian; van Regenmortel, Marc; Kemeny, David M; Power, David; Rossert, Jerome; Casadevall, Nicole

    2005-06-01

    The incidence of pure red cell aplasia (PRCA) in chronic kidney disease patients treated with epoetins increased substantially in 1998, was shown to be antibody mediated, and was associated predominantly with subcutaneous administration of Eprex. A technical investigation identified organic compounds leached from uncoated rubber stoppers in prefilled syringes containing polysorbate 80 as the most probable cause of the increased immunogenicity. This study investigated whether the incidence of PRCA was higher for exposure to the product form containing leachates than for leachate-free product forms. Antibody-mediated PRCA cases were classified according to indication, product form, and route of administration. Exposure estimates were obtained by country, indication, route of administration, and product form. For 2001 to 2003, the PRCA incidence rate for patients with subcutaneous exposure to Eprex in prefilled syringes with polysorbate 80 and uncoated rubber stoppers (leachates present) was 4.61/10,000 patient years (95% CI 3.88-5.43) versus 0.26/10,000 patient years (95% CI 0.007-1.44) for syringes with coated stoppers (leachates absent). The rate difference was 4.35/10,000 patient years (95% CI 3.44-5.26; P < 0.0001); the rate ratio was 17 (95% CI 3.14-707). A substantial rate difference remained in sensitivity analyses that adjusted for exposure to multiple product forms. The epidemiologic data, together with the chemical and immunologic data, support the hypothesis that leachates from uncoated rubber syringe stoppers caused the increased incidence of PRCA associated with Eprex. Currently, all Eprex prefilled syringes contain fluoro-resin coated stoppers, which has contributed to decreased incidence of PRCA with continued surveillance.

  9. Pressures of Wilderness Improvised Wound Irrigation Techniques: How Do They Compare?

    PubMed

    Luck, John B; Campagne, Danielle; Falcón Banchs, Roberto; Montoya, Jason; Spano, Susanne J

    2016-12-01

    Compare the pressures measured by improvised irrigation techniques to a commercial device and to prior reports. Devices tested included a commercial 500-mL compressible plastic bottle with splash guard, a 10-mL syringe, a 10-mL syringe with a 14-ga angiocatheter (with needle removed), a 50-mL Sawyer syringe, a plastic bag punctured with a 14-ga needle, a plastic bottle with cap punctured by a 14-ga needle, a plastic bottle with sports top, and a bladder-style hydration system. Each device was leveled on a support, manually compressed, and aimed toward a piece of glass. A high-speed camera placed behind the glass recorded the height of the stream upon impact at its highest and lowest point. Measurements were recorded 5 times for each device. Pressures in pounds per square inch (psi) were calculated. The syringe and angiocatheter pressures measured the highest pressures (16-49 psi). The 50-mL syringe (7-11 psi), 14-ga punctured water bottle (7-25 psi), and water bottle with sports top (3-7 psi) all measured at or above the commercial device (4-5 psi). Only the bladder-style hydration system (1-2 psi) and plastic bag with 14-ga needle puncture (2-3 psi) did not reach pressures generated by the commercial device. Pressures are consistent with those previously reported. All systems using compressible water bottles and all syringe-based systems provided pressures at or exceeding a commercial wound irrigation device. A 14-ga punctured plastic bag and bladder-style hydration pack failed to generate similar irrigation pressures. Copyright © 2016 Wilderness Medical Society. All rights reserved.

  10. Comparison of spring-loaded, loss of resistance and hanging drop techniques in lumbar epidural blocks.

    PubMed

    Gülen, Güven; Akkaya, Taylan; Ozkan, Derya; Kaydul, Mehmet; Gözaydin, Orhan; Gümüş, Haluk

    2012-01-01

    The spring-loaded syringe is a loss of resistance syringe that provide a more objective sign that the epidural space has been entered compared with the traditional techniques. The aim of this study was to compare the time required to locate the epidural space and the backache incidence with the spring-loaded (SL), loss of resistance (LOR) and the hanging drop (HD) techniques for epidural blocks in patients undergoing transurethral resection procedure. Sixty patients undergoing transurethral resections were enrolled in the study. The patients were randomly assigned to one of three groups. Epidural block was performed in the first group with a spring-loaded syringe (n=20), in the second group with loss-of-resistance syringe (n=20), and in the third group with the hanging drop technique (n=20). The required time to locate the epidural space, the number of attempts, the incidence of dural puncture and the backache incidence were assessed during the procedure and for four weeks after the procedure in all patients. The required time to locate the epidural space was 29.1 ± 9.16 seconds in Group 1; 45.25 ± 19.58 seconds in Group 2, and 47.35 ± 11.42 seconds in Group 3 (p<0.001). In Group 1 this was significantly shorter than the other two groups. There was no significant difference in the number of attempts, the incidence of dural puncture and backache incidence between the three groups (p>0.05). The use of SL syringe was found to have a shorter time period to locate the epidural space when compared with the LOR syringe and hanging drop technique.

  11. Expediting red blood cell transfusions by syringing causes significant hemolysis.

    PubMed

    De Villiers, Willem Lambertus; Murray, Adriaan Albertus; Levin, Andrew Ian

    2017-11-01

    Techniques commonly used to expedite blood transfusions include pneumatically pressurizing red blood cell (RBC) bags or manual syringing its contents. We compared these techniques on RBC hemolysis using a simulated transfusion model. Fifteen warmed RBC units that were 12.3 ± 4.3 (95% confidence interval [CI], 10.1-14.5) days old were each subjected to two experimental rapid transfusion techniques. RBCs from each technique were directed through 18- and 22-gauge cannulas attached to blood administration sets. One technique involved RBC bag pressurization to 300 mmHg. The other employed a 20-mL syringe to effect forceful, manual aspiration from the RBC bag followed by forceful, manual RBC injection. The control group was gravity driven without cannulas. Free hemoglobin (Hb) concentrations were measured and percent hemolysis was calculated. Free Hb concentrations and percent hemolysis (median [95% CI]) were similar in the control (0.05 [0.03-0.08] g/dL and 0.13% [0.09%-0.17%], respectively) and pressurized experiments (0.06 [0.05-0.09] g/dL; 0.14% [0.12%-0.22%]), respectively. Syringing resulted in 10-fold higher free Hb concentrations (0.55 [0.38-0.92] g/dL) and percent hemolysis (1.28% [1.03%-2.15%]) than when employing the control (p < 0.0001) or pressurization (p < 0.0001) techniques. Cannula sizes studied did not affect hemolysis. Forceful manual syringing caused significant hemolysis and high free Hb concentrations. Pressurizing RBC bags induced no more hemolysis than after gravity-facilitated transfusions. Syringing to expedite RBC transfusions should be avoided in favor of pneumatic RBC bag pressurization. © 2017 AABB.

  12. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    PubMed Central

    Alexander, Robert W; Harrell, David B

    2013-01-01

    Objectives Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF) for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG) with use of disposable, microcannula systems. Design Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are available as safe, sterile, disposable, compact systems for acquiring high-quality AFG. Presented is a detailed, step-by-step, proven protocol for performing quality autologous structural adipose transplantation. PMID:23630430

  13. Adrenaline in cardiac arrest: Prefilled syringes are faster.

    PubMed

    Helm, Claire; Gillett, Mark

    2015-08-01

    Standard ampoules and prefilled syringes of adrenaline are widely available in Australasian EDs for use in cardiac arrest. We hypothesise that prefilled syringes can be administered more rapidly and accurately when compared with the two available standard ampoules. This is a triple arm superiority study comparing the time to i.v. administration and accuracy of dosing of three currently available preparations of adrenaline. In their standard packaging, prefilled syringes were on average more than 12 s faster to administer than the 1 mL 1:1000 ampoules and more than 16 s faster than the 10 mL 1:10,000 ampoules (P < 0.01 in both comparisons). With packaging removed, the time to administration was equal for the 1 mL (1:1000) ampoule and the prefilled syringe. Accuracy of dosing was excellent with both the 10 mL (1:10 000) ampoules and prefilled syringes. The 1 mL (1:1000) ampoules delivered a small number of markedly inaccurate doses, but these did not reach statistical significance. The speed of administration of adrenaline utilising a Minijet (CSL Limited, Parkville, Victoria, Australia) is faster than using adrenaline in glass ampoules presented in their plastic packaging. Removing the plastic packaging from the 1 mL (1 mg) ampoule might result in more rapid administration similar to the Minijet. Resuscitation personnel requiring rapid access to adrenaline should consider storing it as either Minijets or ampoules devoid of packaging. These results might be extrapolatable to other clinical scenarios, including pre-hospital and anaesthesia, where other drugs are required for rapid use. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  14. Noise exposure and hearing loss prevention programmes after 20 years of regulations in the United States

    PubMed Central

    Daniell, W E; Swan, S S; McDaniel, M M; Camp, J E; Cohen, M A; Stebbins, J G

    2006-01-01

    Objectives To evaluate noise exposures and hearing loss prevention efforts in industries with relatively high rates of workers' compensation claims for hearing loss. Methods Washington State workers' compensation records were used to identify up to 10 companies in each of eight industries. Each company (n = 76) was evaluated by a management interview, employee personal noise dosimetry (n = 983), and employee interviews (n = 1557). Results Full‐shift average exposures were ⩾85 dBA for 50% of monitored employees, using Occupational Safety and Health Administration (OSHA) parameters with a 5 dB exchange rate (Lave), but 74% were ⩾85 dBA using a 3 dB exchange rate (Leq). Only 14% had Lave ⩾90 dBA, but 42% had Leq ⩾90 dBA. Most companies conducted noise measurements, but most kept no records, and consideration of noise controls was low in all industries. Hearing loss prevention programmes were commonly incomplete. Management interview scores (higher score = more complete programme) showed significant associations with percentage of employees having Lave ⩾85 dBA and presence of a union (multiple linear regression; R2 = 0.24). Overall, 62% of interviewed employees reported always using hearing protection when exposed. Protector use showed significant associations with percentage of employees specifically required to use protection, management score, and average employee time spent ⩾95 dBA (R2 = 0.65). Conclusions The findings raise serious concerns about the adequacy of prevention, regulation, and enforcement strategies in the United States. The percentage of workers with excessive exposure was 1.5–3 times higher using a 3 dB exchange rate instead of the OSHA specified 5 dB exchange rate. Most companies gave limited or no attention to noise controls and relied primarily on hearing protection to prevent hearing loss; yet 38% of employees did not use protectors routinely. Protector use was highest when hearing loss prevention programmes were most complete, indicating that under‐use of protection was, in some substantial part, attributable to incomplete or inadequate company efforts. PMID:16551755

  15. Addressing the HIV/AIDS Epidemic Among Puerto Rican People Who Inject Drugs: The Need for a Multiregion Approach

    PubMed Central

    Gelpí-Acosta, Camila; Albizu-García, Carmen E.; González, Ángel; Des Jarlais, Don C.; Santiago-Negrón, Salvador

    2014-01-01

    High levels of HIV risk behaviors and prevalence have been reported among Puerto Rican people who inject drugs (PRPWID) since early in the HIV epidemic. Advances in HIV prevention and treatment have reduced HIV among people who inject drugs (PWID) in the United States. We examined HIV-related data for PRPWID in Puerto Rico and the US Northeast to assess whether disparities continue. Injection drug use as a risk for HIV is still overrepresented among Puerto Ricans. Lower availability of syringe exchanges, drug abuse treatment, and antiretroviral treatment for PWID in Puerto Rico contribute to higher HIV risk and incidence. These disparities should be addressed by the development of a federally supported Northeast–Puerto Rico collaboration to facilitate and coordinate efforts throughout both regions. PMID:25211722

  16. Occupational Safety in the Age of the Opioid Crisis: Needle Stick Injury among Baltimore Police.

    PubMed

    Cepeda, Javier A; Beletsky, Leo; Sawyer, Anne; Serio-Chapman, Chris; Smelyanskaya, Marina; Han, Jennifer; Robinowitz, Natanya; Sherman, Susan G

    2017-02-01

    At a time of resurgence in injection drug use and injection-attributable infections, needle stick injury (NSI) risk and its correlates among police remain understudied. In the context of occupational safety training, a convenience sample of 771 Baltimore city police officers responded to a self-administered survey. Domains included NSI experience, protective behaviors, and attitudes towards syringe exchange programs. Sixty officers (8%) reported lifetime NSI. Officers identifying as Latino or other race were almost three times more likely (aOR 2.58, 95% CI 1.12-5.96) to have experienced NSI compared to whites, after adjusting for potential confounders. Findings highlight disparate burdens of NSIs among officers of color, elevating risk of hepatitis, HIV, and trauma. Training, equipment, and other measures to improve occupational safety are critical to attracting and safeguarding police, especially minority officers.

  17. Culbertson holds a syringe kit in Destiny during Expedition Three

    NASA Image and Video Library

    2001-08-29

    ISS003-E-5475 (29 August 2001) --- Astronaut Frank L. Culbertson, Expedition Three mission commander, holds a syringe kit to be used in the Quad Tissue Culture Module Assemblies (QTCMA) for the Biotechnology Specimen Temperature Controller (BSTC) experiment in the U.S. Laboratory.

  18. Apparatus Induces And Fixes Small Aquatic Organisms

    NASA Technical Reports Server (NTRS)

    Todd, Christopher

    1992-01-01

    Syringe-and-bag assembly compact, lightweight self-contained, portable apparatus introducing liquids to aquatic organisms. Isolates organisms from toxic substances until time of introduction. Includes plastic syringes, each containing inner, sealed, burstable bag. Adaptable to use in biological tests and experiments at remote locations on Earth.

  19. 21 CFR 880.6920 - Syringe needle introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Syringe needle introducer. 880.6920 Section 880.6920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... depth below the skin surface. (b) Classification. Class II (performance standards). ...

  20. 21 CFR 880.6920 - Syringe needle introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Syringe needle introducer. 880.6920 Section 880.6920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... depth below the skin surface. (b) Classification. Class II (performance standards). ...

  1. Mercaptopurine

    MedlinePlus

    ... is important to use an oral syringe (measuring device) to accurately measure and take your dose of mercaptopurine. If you do not ... one. After you use the oral syringe to take your medication, remove the plunger from the rest of the measuring device, wash both parts with warm soapy water, and ...

  2. Needle and syringe sharing practices of injecting drug users participating in an outreach HIV prevention program in Tehran, Iran: A cross-sectional study

    PubMed Central

    Vazirian, Mohsen; Nassirimanesh, Bijan; Zamani, Saman; Ono-Kihara, Masako; Kihara, Masahiro; Mortazavi Ravari, Shahrzad; Gouya, Mohammad Mehdi

    2005-01-01

    HIV infection rates have reached epidemic proportions amongst injecting drug users (IDUs) in Iran. Although a number of community-based interventions have being implemented in the country, there is little information on the risk behaviors of IDU participants in these programs. This cross-sectional report aimed to compare the risk behaviors of injecting drug users with differential exposure rates to an HIV outreach program in Tehran, Iran. Results indicated that shared use of needle/syringe in the past month was significantly lower among IDUs who received estimated ≥ 7 syringes per week than those who did not [adjusted odds ratio (OR) = 14.36, 95% confidence interval (CI) 2.30–89.56]. While the effectiveness of this outreach program needs further evaluation through a longitudinal investigation, our preliminary findings suggest that the outreach program in Tehran may have been beneficial in reducing direct sharing among those who received more than several needles/syringes from the program. PMID:16212655

  3. Comparison of utilization, cost, adherence, and hypoglycemia in patients with type 2 diabetes initiating rapid-acting insulin analog with prefilled pen versus vial/syringe.

    PubMed

    Lee, Lauren J; Li, Qian; Reynolds, Matthew W; Pawaskar, Manjiri D; Corrigan, Sheila M

    2011-01-01

    Studies examining outcomes of different insulin delivery systems are limited. The objective of this study was to compare healthcare utilization, costs, adherence, and hypoglycemia rates in patients with type 2 diabetes mellitus (T2DM) initiating rapid-acting insulin analog (RAIA) using prefilled pen versus vial/syringe. A retrospective analysis was conducted using a US claims database (1/1/2007 to 12/31/2008). Inclusion criteria were: ≥18 years old, with T2DM, ≥12 months of continuous eligibility, and new to RAIA. Difference-in-difference analyses after propensity score matching were conducted to compare changes in outcomes from 6 months prior to and 6 months after initiating RAIA with a prefilled pen versus vial/syringe (Wilcoxon rank-sum test for costs and t-test for other outcomes). Categories of utilization and costs (2009 USD) included total and diabetes-related inpatient, outpatient, and emergency room. Adherence was measured by proportion of days covered (PDC). Hypoglycemia was identified using ICD-9-CM codes. Baseline characteristics were similar between the prefilled pen (n = 239) and vial/syringe (n = 590) cohorts after matching. Adherence to RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (PDC: 54.6 vs. 45.2%, p < 0.001). While the increase in diabetes-related pharmacy costs from before to after initiating RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (+$900 vs. +$607, p < 0.001), the prefilled pen cohort was associated with greater reductions in the total diabetes-related costs (-$235 vs. +$61, p = 0.006) and the utilization of oral anti-hyperglycemic agents (-1.3 vs. -0.7, p = 0.016). There were no significant differences in other outcomes. Claims databases do not provide optimal measures for adherence or T2DM severity, and only capture hypoglycemia events requiring clinical intervention. Initiating RAIA with a prefilled pen was associated with better adherence and greater reduction in total diabetes-related costs than a vial/syringe. There was no significant difference in total healthcare costs.

  4. Social marketing of low dead space syringes in Vietnam: findings from a 1-year pilot program in Hanoi, Thai Nguyen, and Ho Chi Minh City.

    PubMed

    Huong, Ngo Thi Thanh; Mundy, Gary; Neukom, Josselyn; Zule, William; Tuan, Nguyen Minh; Tam, Nguyen Minh

    2015-05-30

    Although a growing body of evidence suggests that low dead space syringes may reduce the risk of human immunodeficiency virus (HIV) and Hepatitis C virus infection associated with sharing syringes among people who inject drugs, there is little evidence of effective approaches to motivate people who inject drugs (PWID) to shift from high to low dead space syringes. Using a mix of consumer and trade marketing approaches, informed by rapid assessments of both the syringe market and PWID preferences, practices, and behaviors in Hanoi and Ho Chi Minh City, Population Services International (PSI) Vietnam piloted an intervention to increase the use of low dead space syringes (LDSS) in the three provinces of Hanoi, Ho Chi Minh City, and Thai Nguyen, where an estimated 31% of PWID are HIV positive and 58% are living with hepatitis C virus (HCV). This paper provides a summary of the social marketing activities implemented and results achieved by PSI Vietnam during an initial 1-year pilot period from December 2012 to December 2013 in these three provinces to explore their effectiveness in motivating PWID to use low dead space syringes. We found major increases in sales of LDSS accompanied by increases in reported use and consistent use of LDSS among PWID in the three provinces included in the pilot program and a positive and independent association (odds ratio (OR) 21.08; 95% confidence interval (CI) 10.6-27.3) between LDSS use and exposure to social marketing activities. We also found that LDSS use had a stronger association with perceptions of LDSS product quality than with perceptions regarding LDSS potential to reduce HIV transmission risk and use. We conclude that social marketing interventions have an important role to play in widening access to and the use of LDSS for PWID, as they address the need for PWID to find LDSS when and where they need them and also promote the benefits of LDSS use to PWID. High coverage of these activities among PWID appears to be the key in achieving these successes.

  5. The case of a needle exchange policy debate in Fresno, California

    PubMed Central

    Clarke, KRIS

    2016-01-01

    Needle exchange is one of the most effective public health interventions to prevent the transmission of infectious disease by injecting drug users. Despite the preponderance of scientific evidence, US federal funding for needle exchange programmes has been banned since 1988. This prohibition has resulted in the lack of a centralised policy on needle exchange and has given birth to a patchwork of diverse practices and regulations throughout the nation. This article focuses on how various local players interpreted the meaning of needle exchange through the debate on an unauthorised site in Fresno, California. In exploring a specific context, this study delineates the narratives used to outline competing views about needle exchange and to offer a snapshot of how the issue of widespread injecting drug use was handled in an impoverished and socially conservative region of the United States. PMID:28035171

  6. Solid phase microextraction field kit

    DOEpatents

    Nunes, Peter J.; Andresen, Brian D.

    2005-08-16

    A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.

  7. 21 CFR 870.1650 - Angiographic injector and syringe.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Angiographic injector and syringe. 870.1650 Section 870.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1650 Angiographic...

  8. 21 CFR 870.1650 - Angiographic injector and syringe.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Angiographic injector and syringe. 870.1650 Section 870.1650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1650 Angiographic...

  9. 40 CFR Appendix A to Part 136 - Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the learest 0.1 mg. 6.5.2Add the assayed reference material: 6.5.2.1Liquid—Using a 100 µL syringe... chromatograph and all required accessories including syringes, analytical columns, and gases. The injection port...

  10. 40 CFR Appendix A to Part 136 - Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the learest 0.1 mg. 6.5.2Add the assayed reference material: 6.5.2.1Liquid—Using a 100 µL syringe... chromatograph and all required accessories including syringes, analytical columns, and gases. The injection port...

  11. Adiabatic Compression in a Fire Syringe.

    ERIC Educational Resources Information Center

    Hayn, Carl H.; Baird, Scott C.

    1985-01-01

    Suggests using better materials in fire syringes to obtain more effective results during demonstrations which show the elevation in temperature upon a very rapid (adiabatic) compression of air. Also describes an experiment (using ignition temperatures) which introduces students to the use of thermocouples for high temperature measurements. (DH)

  12. Comparing risk environments for HIV among people who inject drugs from three cities in Northern Mexico.

    PubMed

    Ospina-Escobar, Angelica; Magis-Rodríguez, Carlos; Juárez, Fatima; Werb, Dan; Bautista Arredondo, Sergio; Carreón, Rubén; Ramos, María Elena; Strathdee, Steffanie

    2018-05-18

    A large body of research has investigated the rise of injection drug use and HIV transmission in Tijuana and Ciudad Juarez (CJ). However, little is known about the dynamics of injecting in Hermosillo. This study compares drug-related behaviors and risk environment for HIV of people who inject drugs (PWID) across Tijuana, CJ, and Hermosillo to identify factors that could explain differences in HIV prevalence. Data from Tijuana belong to a prospective study (El Cuete IV). Data from Hermosillo and Ciudad Juarez belong to a cross-sectional study. Both studies collected data in places where PWID spend time. All participants completed quantitative behavioral and serological testing for HIV. Datasets were merged using only comparable variables. Descriptive statistics tests were used to compare sociodemographic and behavioral characteristics of people who inject drugs PWID sampled in each city. A logistic regression model was built to identify factors independently associated with the likelihood of reporting receptive syringe sharing in the past 6 months. A total of 1494 PWID provided data between March 2011 and May 2012. HIV prevalence differed significantly between participants in Tijuana (4.2%), CJ (7.7%), and Hermosillo (5.2%; p < 0.05). PWID from Hermosillo reported better living conditions, less frequency of drug injection, and lower prevalence of syringe sharing (p < 0.01). PWID from CJ reported a higher prevalence of syringe sharing and confiscation by police (p < 0.01). In a multivariable logistic regression model, living in Hermosillo compared to Tijuana (adjusted odds ratio [AOR] = 0.42, 95% confidence interval [CI] 0.29-0.61) and being female (AOR = 0.61, 95% CI 0.45-0.83) were protective against syringe sharing. Having used crystal meth (AOR = 1.62, 95% CI 1.24-2.13, p = 0.001), having experienced syringe confiscation by police in the last 6 months (AOR = 1.78, 95% CI 1.34-2.40), and lower perception of syringe availability (AOR = 2.15, 95% CI 1.59-2.91) were significantly associated with syringe sharing (p < 0.05). Differences in HIV prevalence across cities reflect mainly differences in risk environments experienced by PWID, shaped by police practices, access to injection equipment, and dynamics of drug markets. Findings highlight the importance of ensuring sterile syringe availability through harm reduction services and a human rights approach to drug harms in northern Mexico and to generate better understanding of local dynamics and contexts of drug use for designing proper harm reduction programs.

  13. Syringeless power injector versus dual-syringe power injector: economic evaluation of user performance, the impact on contrast enhanced computed tomography (CECT) workflow exams, and hospital costs.

    PubMed

    Colombo, Giorgio L; Andreis, Ivo A Bergamo; Di Matteo, Sergio; Bruno, Giacomo M; Mondellini, Claudio

    2013-01-01

    The utilization of diagnostic imaging has substantially increased over the past decade in Europe and North America and continues to grow worldwide. The purpose of this study was to develop an economic evaluation of a syringeless power injector (PI) versus a dual-syringe PI for contrast enhanced computed tomography (CECT) in a hospital setting. Patients (n=2379) were enrolled at the Legnano Hospital between November 2012 and January 2013. They had been referred to the hospital for a CECT analysis and were randomized into two groups. The first group was examined with a 256-MDCT (MultiDetector Computed Tomography) scanner using a syringeless power injector, while the other group was examined with a 64-MDCT scanner using a dual-syringe. Data on the operators' time required in the patient analysis steps as well as on the quantity of consumable materials used were collected. The radiologic technologists' satisfaction with the use of the PIs was rated on a 10-point scale. A budget impact analysis and sensitivity analysis were performed under the base-case scenario. A total of 1,040 patients were examined using the syringeless system, and 1,339 with the dual-syringe system; the CECT examination quality was comparable for both PI systems. Equipment preparation time and releasing time per examination for syringeless PIs versus dual-syringe PIs were 100±30 versus 180±30 seconds and 90±30 and 140±20 seconds, respectively. On average, 10±3 mL of contrast media (CM) wastage per examination was observed with the dual-syringe PI and 0±1 mL with the syringeless PI. Technologists had higher satisfaction with the syringeless PI than with the dual-syringe system (8.8 versus 8.0). The syringeless PI allows a saving of about €6.18 per patient, both due to the lower cost of the devices and to the better performance of the syringeless system. The univariate sensitivity analysis carried out on the base-case results within the standard deviation range confirmed the saving generated by using the syringeless device, with saving values between €5.40 and €6.20 per patient. The syringeless PI was found to be more user-friendly and efficient, minimizing contrast wastage and providing similar contrast enhancement quality compared to the dual-syringe injector, with comparable CECT examination quality.

  14. Evaluation of the Amount of Debris extruded apically by using Conv-entional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study

    PubMed Central

    Tambe, Varsha H; Nagmode, Pradnya S; Vishwas, Jayshree R; P, Saujanya K; Angadi, Prabakar; Ali, Fareedi Mukram

    2013-01-01

    Background: To compare the amount of debris extruded apically by using conventional syringe, Endovac & Ultrasonic irrigation. Materials & Methods: Thirty freshly extracted mandibular premolars were selected, working length was determined and mounted in a debris and collection apparatus. The canals were prepared. After each instrument change, 1 ml. of 3% sodium hypochlorite was used as irrigation. Debris extruded apically by using conventional syringe, endovac& ultrasonic irrigation tech, was measured using the electronic balance to determine its weight and statistical analysis was performed. The mean difference between the groups was determined using statistical analysis within the groups &between the groups for equal variances. Results: Among all the groups, significantly less debris were found apically in the Endovac group (0.96) compared to conventional and ultrasonic group (1.23) syringe. Conclusion: The present study showed that endovac system extrudes less amount of debris apically as compared to ultrasonic followed by conventional so incidence of flare up can be reduce by using endovac irrigation system. How to cite this article: Tambe V H, Nagmode P S, Vishwas J R, Saujanya K P, Angadi P, Ali F M. Evaluation of the Amount of Debris extruded apically by using Conventional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study. J Int Oral Health 2013; 5(3):63-66. PMID:24155604

  15. Stability of thiopental sodium and propofol in polypropylene syringes at 23 and 4 degrees C.

    PubMed

    Chernin, E L; Stewart, J T; Smiler, B

    1996-07-01

    The stability of thiopental sodium and propofol in an admixture stored in polypropylene syringes at room temperature and under refrigeration was studied. Propofol injection 10 mg/ mL and thiopental sodium 25 mg/mL were mixed to final concentrations of 5 and 12.5 mg/mL, respectively. The admixture was put into 60-mL polypropylene syringes, and two syringes were stored at 23 degrees C and two at 4 degrees C. For solutions stored at 23 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, 240, and 264 hours, and for samples stored at 4 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, and 312 hours. Drug concentrations were determined by high-performance liquid chromatography. Thiopental sodium and propofol retained > 90% of their initial concentrations for up to 312 hours at 4 degrees C. At 23 degrees C, > 90% of the initial concentration was retained by propofol for up to 120 hours and by thiopental sodium for up to 240 hours. No visual changes or significant change in pH occurred in any sample. When mixed and stored in polypropylene syringes, propofol 5 mg/mL and thiopental sodium 12.5 mg/mL were stable for up to 312 hours at 4 degrees C and for up to 120 hours at 23 degrees C.

  16. An Improved Syringe Agroinfiltration Protocol to Enhance Transformation Efficiency by Combinative Use of 5-Azacytidine, Ascorbate Acid and Tween-20.

    PubMed

    Zhao, Huimin; Tan, Zilong; Wen, Xuejing; Wang, Yucheng

    2017-02-14

    Syringe infiltration is an important transient transformation method that is widely used in many molecular studies. Owing to the wide use of syringe agroinfiltration, it is important and necessary to improve its transformation efficiency. Here, we studied the factors influencing the transformation efficiency of syringe agroinfiltration. The pCAMBIA1301 was transformed into Nicotiana benthamiana leaves for investigation. The effects of 5-azacytidine (AzaC), Ascorbate acid (ASC) and Tween-20 on transformation were studied. The β-glucuronidase ( GUS ) expression and GUS activity were respectively measured to determine the transformation efficiency. AzaC, ASC and Tween-20 all significantly affected the transformation efficiency of agroinfiltration, and the optimal concentrations of AzaC, ASC and Tween-20 for the transgene expression were identified. Our results showed that 20 μM AzaC, 0.56 mM ASC and 0.03% ( v / v ) Tween-20 is the optimal concentration that could significantly improve the transformation efficiency of agroinfiltration. Furthermore, a combined supplement of 20 μM AzaC, 0.56 mM ASC and 0.03% Tween-20 improves the expression of transgene better than any one factor alone, increasing the transgene expression by more than 6-fold. Thus, an optimized syringe agroinfiltration was developed here, which might be a powerful method in transient transformation analysis.

  17. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    PubMed

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. 41 CFR 109-27.5009 - Control of hypodermic needles and syringes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Control of hypodermic... SUPPLY AND PROCUREMENT 27-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5009 Control of hypodermic needles and syringes. Effective procedures and practices shall...

  19. 21 CFR 520.45a - Albendazole suspension.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver...) body weight (10 mg/kilogram (kg)) as a single oral dose using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver flukes (Fasciola hepatica); heads and segments of...

  20. 21 CFR 520.38a - Albendazole suspension.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver...) body weight (10 mg/kilogram (kg)) as a single oral dose using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver flukes (Fasciola hepatica); heads and segments of...

  1. 21 CFR 520.45a - Albendazole suspension.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver...) body weight (10 mg/kilogram (kg)) as a single oral dose using dosing gun or dosing syringe. (ii) Indications for use. For removal and control of adult liver flukes (Fasciola hepatica); heads and segments of...

  2. A Simple Boyle's Law Experiment.

    ERIC Educational Resources Information Center

    Lewis, Don L.

    1997-01-01

    Describes an experiment to demonstrate Boyle's law that provides pressure measurements in a familiar unit (psi) and makes no assumptions concerning atmospheric pressure. Items needed include bathroom scales and a 60-ml syringe, castor oil, disposable 3-ml syringe and needle, modeling clay, pliers, and a wooden block. Commercial devices use a…

  3. The Disposable Syringe: More Experiments and Uses

    ERIC Educational Resources Information Center

    Farmer, Andrew

    1973-01-01

    Describes a variety of experiments that can be performed using the disposable syringe. Among others, these include the removal of oxygen during rusting, convection in a liquid and in air, gas collection in an electrolysis cell, small scale production of a fog, and hydrogen/oxygen extraction from a voltameter. (JR)

  4. A Programmable Smoke Delivery Device for PET Imaging with Cigarettes Containing 11C-nicotine

    PubMed Central

    Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G

    2017-01-01

    Introduction PET imaging with 11C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. New method The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11C-nicotine-loaded cigarette. Results Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. Comparison with existing methods This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. Conclusions The SDD is effective in delivering 11C-nicotine from the study cigarettes. Despite a 2-sec increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. PMID:28347784

  5. A programmable smoke delivery device for PET imaging with cigarettes containing 11C-nicotine.

    PubMed

    Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G

    2017-05-01

    PET imaging with 11 C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11 C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11 C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11 C-nicotine-loaded cigarette. Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. The SDD is effective in delivering 11 C-nicotine from the study cigarettes. Despite a 2-s increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11 C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. 21 CFR 872.4465 - Gas-powered jet injector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas-powered jet injector. 872.4465 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4465 Gas-powered jet injector. (a) Identification. A gas-powered jet injector is a syringe device intended to administer a local anesthetic. The syringe is...

  7. 21 CFR 872.4465 - Gas-powered jet injector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas-powered jet injector. 872.4465 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4465 Gas-powered jet injector. (a) Identification. A gas-powered jet injector is a syringe device intended to administer a local anesthetic. The syringe is...

  8. Electrospinning-based synthesis of highly ordered mesoporous silica fiber for lab-in-syringe enrichment of plasma peptides.

    PubMed

    Zhu, Gang-Tian; Li, Xiao-Shui; Fu, Xiao-Meng; Wu, Jian-Yuan; Yuan, Bi-Feng; Feng, Yu-Qi

    2012-10-14

    Silica fiber with highly ordered mesoporous structure and continuously long fibrous property was synthesized on a large-scale for the first time. It can be applied to the rapid (less than 3 min) and effective enrichment of endogenous peptides with a novel lab-in-syringe approach.

  9. Microscale Gas Chemistry

    ERIC Educational Resources Information Center

    Mattson, Bruce; Anderson, Michael P.

    2011-01-01

    The development of syringes having free movement while remaining gas-tight enabled methods in chemistry to be changed. Successfully containing and measuring volumes of gas without the need to trap them using liquids made it possible to work with smaller quantities. The invention of the LuerLok syringe cap also allowed the gas to be stored for a…

  10. Dual controlled release, in situ gelling periodontal sol of metronidazole benzoate and serratiopeptidase: statistical optimization and mechanistic evaluation.

    PubMed

    Kumari, Neeraj; Pathak, Kamla

    2012-01-01

    In situ gelling syringeable periodontal sol capable of dual controlled delivery of metronidazole benzoate and serratiopeptidase was designed based on 2(3) factorial design with drug, poloxamer 407 and aerosil as independent variables and sol gel transition characteristics, %CDR(48h) and palatability as responses. The sols had agreeable taste, were mucoadhesive, syringeable and inverted into gels at periodontal cavity temperature. F8 with optimal drug release was identified as the best formulation. The dispersion characteristics of poloxamer significantly affected the pharmacotechnical properties of the in situ gelling systems. Extra design checkpoint generated using Design Expert software 8.02 (Stat-Ease, USA) validated the experimental design. Thus a thermoreversible, in situ gelling and syringeable periodontal sol with acceptable taste characteristics that offered controlled release of metronidazole benzoate and serratiopeptidase was developed for application into the periodontal pocket. The developed optimized sol was satisfactory in terms of taste, syringeability, palatability and incorporation of serratiopeptidase as anti-inflammatory agent, has the potential of developing a therapeutically efficacious system for treatment of periodontal inflammatory anaerobic infections.

  11. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    PubMed

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. Isolation of HIV-1 from experimentally contaminated multidose local anaesthetic vials.

    PubMed

    Druce, J D; Locarnini, S A; Birch, C J

    1995-05-15

    To investigate the hypothesis that HIV can be transmitted via contamination of multidose vials of local anaesthetic solution through reuse of needles and syringes. Laboratory study. (1) By experiments with multidose vials and disposable needles and syringes, we identified a sequence of events in which HIV could contaminate the anaesthetic solution. (2) Three anaesthetic solutions were contaminated with a laboratory strain of HIV and tested by viral culture and p24 enzyme immunoassay one, two and four hours later to see how long the virus remained active. (1) Needles and syringes retained small volumes of fluid after use (mean, 25 microL; in syringe alone, mean 16 microL) which could be transferred to multidose vials of local anaesthetic. (2) 10 mL of anaesthetic solution contaminated with 8 microL of HIV-infected solution (equivalent to 1% infected lymphocytes in vivo) contained active virus one hour later. In some settings, HIV could be isolated four hours after exposure. When inadvertently contaminated with HIV, multidose solutions represent a potential source of transmissible virus.

  13. A new syringe pump apparatus for the retrieval and temporal analysis of helium in groundwaters and geothermal fluids

    USGS Publications Warehouse

    Barry, P.H.; Hilton, David R.; Tryon, M.D.; Brown, K.M.; Kulongoski, J.T.

    2009-01-01

    [1] We present details of a newly designed syringe pump apparatus for the retrieval and temporal analysis of helium (SPARTAH). The device is composed of a commercially available syringe pump connected to coils of Cu tubing, which interface the syringe and the groundwater or geothermal wellhead. Through test deployments at geothermal wells in Iceland and California, we show that well fluids are drawn smoothly, accurately, and continuously into the Cu tubing and can be time-stamped through user-determined operating parameters. In the laboratory, the tubing is sectioned to reveal helium (He) characteristics of the fluids at times and for durations of interest. The device is capable of prolonged deployments, up to 6 months or more, with minimal maintenance. It can be used to produce detailed time series records of He, or any other geochemical parameter, in groundwaters and geothermal fluids. SPARTAH has application in monitoring projects assessing the relationship between external transient events (e.g., earthquakes) and geochemical signals in aqueous fluids. ?? 2009 by the American Geophysical Union.

  14. Global health: A lasting partnership in paediatric surgery

    PubMed Central

    Lakhoo, Kokila; Msuya, David

    2015-01-01

    Background: To emphasise the value of on-going commitment in Global Health Partnerships. Materials and Methods: A hospital link, by invitation, was set up between United Kingdom and Tanzania since 2002. The project involved annual visits with activities ranging from exchange of skill to training health professionals. Furthermore, the programme attracted teaching and research activities. For continuity, there was electronic communication between visits. Results: Six paediatric surgeons are now fully trained with three further in training in Africa. Paediatric surgery services are now separate from adult services. Seven trainee exchanges have taken place with four awarded fellowships/scholarships. Twenty-three clinical projects have been presented internationally resulting in eight international publications. The programme has attracted other health professionals, especially nursing and engineering. The Tropical Health and Education Trust prize was recently achieved for nursing and radiography. National Health Service has benefited from volunteering staff bringing new cost-effective ideas. A fully funded medical student elective programme has been achieved since 2008. Conclusion: Global Health Partnerships are an excellent initiative in establishing specialist services in countries with limited resources. In the future, this will translate into improved patient care as long as it is sustained and valued by long term commitment. PMID:26168748

  15. Global health: A lasting partnership in paediatric surgery.

    PubMed

    Lakhoo, Kokila; Msuya, David

    2015-01-01

    To emphasise the value of on-going commitment in Global Health Partnerships. A hospital link, by invitation, was set up between United Kingdom and Tanzania since 2002. The project involved annual visits with activities ranging from exchange of skill to training health professionals. Furthermore, the programme attracted teaching and research activities. For continuity, there was electronic communication between visits. Six paediatric surgeons are now fully trained with three further in training in Africa. Paediatric surgery services are now separate from adult services. Seven trainee exchanges have taken place with four awarded fellowships/scholarships. Twenty-three clinical projects have been presented internationally resulting in eight international publications. The programme has attracted other health professionals, especially nursing and engineering. The Tropical Health and Education Trust prize was recently achieved for nursing and radiography. National Health Service has benefited from volunteering staff bringing new cost-effective ideas. A fully funded medical student elective programme has been achieved since 2008. Global Health Partnerships are an excellent initiative in establishing specialist services in countries with limited resources. In the future, this will translate into improved patient care as long as it is sustained and valued by long term commitment.

  16. Implementation study of patient-ready syringes containing 25 mg/mL methotrexate solution for use in treating ectopic pregnancy.

    PubMed

    Respaud, R; Gaudy, A S; Arlicot, C; Tournamille, J F; Viaud-Massuard, M C; Elfakir, C; Antier, D

    2014-01-01

    Ectopic pregnancy (EP) is a significant cause of morbidity and mortality during the first trimester of pregnancy. Small unruptured tubal pregnancies can be treated medically with a single dose of methotrexate (MTX). The aim of this study was to evaluate the stability of a 25 mg/mL solution of MTX to devise a secure delivery circuit for the preparation and use of this medication in the management of EP. MTX solutions were packaged in polypropylene syringes, stored over an 84-day period, and protected from light either at +2 to +8°C or at 23°C. We assessed the physical and chemical stability of the solutions at various time points over the storage period. A pharmaceutical delivery circuit was implemented that involved the batch preparation of MTX syringes. We show that 25 mg/mL MTX solutions remain stable over an 84-day period under the storage conditions tested. Standard doses were prepared, ranging from 50 mg to 100 mg. The results of this study suggest that MTX syringes can be prepared in advance by the pharmacy, ready to be dispensed at any time that a diagnosis of EP is made. The high stability of a 25 mg/mL MTX solution in polypropylene syringes makes it possible to implement a flexible and cost-effective delivery circuit for ready-to-use preparations of this drug, providing 24-hour access and preventing treatment delays.

  17. Self-reported injection practices among people who use drugs in French prisons: Public health implications (ANRS-Coquelicot survey 2011-2013).

    PubMed

    Michel, Laurent; Trouiller, Philippe; Chollet, Aude; Molinier, Marie; Duchesne, Lucie; Jauffret-Roustide, Marie

    2018-04-01

    The aims of this study were to describe the prevalences of injection practices and needle/syringe sharing in people who use drugs in French prisons, and to investigate associated factors. Using the ANRS-Coquelicot survey (2011-2013), a random sample of 1718 people who used drugs in free society was included. Information regarding a history of incarceration, drug-injection practices inside prison and needle/syringe sharing was collected during interviews. In our sample, 65.5% reported a history of injection and 57.4% had been incarcerated at least once. Among those who reported both of these conditions, 14% reported injection practices inside prison, 40.5% of whom had shared needles/syringes. In the multivariable model, the following variables were associated with injection practices inside prison: being a Russian-speaking detainee, having spent more time in prison, and having started to inject before 1996 and especially before 1987. Being Russian speaking was also associated with needle/syringe sharing in prison. The prevalences of injection practices and needle/syringe sharing in prisons are alarmingly high. Effective interventions to prevent the transmission of infectious diseases among people who use drugs in the prison setting are essential. The implementation of international recommendations on the principle of equivalence between prisons and the community is still very limited in most countries, and should be complemented with tailored interventions for the most vulnerable prison populations, especially Russian-speaking detainees. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  18. In-Syringe Micro Solid-Phase Extraction Method for the Separation and Preconcentration of Parabens in Environmental Water Samples.

    PubMed

    Mashile, Geaneth Pertunia; Mpupa, Anele; Nomngongo, Philiswa Nosizo

    2018-06-14

    In this study, a simple, rapid and effective in-syringe micro-solid phase extraction (MSPE) method was developed for the separation and preconcetration of parabens (methyl, ethyl, propyl and butyl paraben) in environmental water samples. The parabens were determined and quantified using high performance liquid chromatography and a photo diode array detector (HPLC-PDA). Chitosan-coated activated carbon (CAC) was used as the sorbent in the in-syringe MSPE device. A response surface methodology based on central composite design was used for the optimization of factors (eluent solvent type, eluent volume, number of elution cycles, sample volume, sample pH) affecting the extraction efficiency of the preconcentration procedure. The adsorbent used displayed excellent absorption performance and the adsorption capacity ranged from 227⁻256 mg g −1 . Under the optimal conditions the dynamic linear ranges for the parabens were between 0.04 and 380 µg L −1 . The limits of detection and quantification ranged from 6⁻15 ng L −1 and 20⁻50 ng L −1 , respectively. The intraday (repeatability) and interday (reproducibility) precisions expressed as relative standard deviations (%RSD) were below 5%. Furthermore, the in-syringe MSPE/HPLC procedure was validated using spiked wastewater and tap water samples and the recoveries ranged between from 96.7 to 107%. In conclusion, CAC based in-syringe MSPE method demonstrated great potential for preconcentration of parabens in complex environmental water.

  19. Assessing police officers' attitudes and legal knowledge on behaviors that impact HIV transmission among people who inject drugs.

    PubMed

    Cepeda, Javier A; Strathdee, Steffanie A; Arredondo, Jaime; Mittal, Maria L; Rocha, Teresita; Morales, Mario; Clairgue, Erika; Bustamante, Eliane; Abramovitz, Daniela; Artamonova, Irina; Bañuelos, Arnulfo; Kerr, Thomas; Magis-Rodriguez, Carlos L; Beletsky, Leo

    2017-12-01

    Policing practices such as syringe confiscation and arrest can act as important social-structural drivers of HIV risk among people who inject drugs (PWID). However, police referral to treatment and other services may improve the health of PWID. Little is known about the role of modifiable attitudinal and knowledge factors in shaping officer behavior. Using baseline findings from a police education program (PEP), we assessed relationships between drug policy knowledge and attitudes towards public health interventions with self-reported syringe confiscation, drug arrest, and service referral among street-level police in Tijuana, Mexico. Between February, 2015 and May, 2016 we surveyed 1319 police officers who reported syringe contact. The self-administered survey focused on attitudes, knowledge, and behaviors related to drug policy, public health, and occupational safety. We used ordinal logistic regression to model the odds of syringe confiscation, arrest for heroin possession, and referring PWID to health/social programs. The sample was mostly male (87%) and had at least a high school education (80%). In the last six months, a minority reported always/sometimes confiscating syringes (49%), arresting someone for heroin possession (43%), and referring PWID to health and social programs (37%). Those reporting needlestick injuries (NSI) had 1.38 (95% CI: 1.02-1.87) higher odds of reporting syringe confiscation. Officers who had favorable views on laws that treat addiction as a public health issue had lower odds (aOR=0.78; 95% CI: 0.59-1.03) of arresting PWID. Those agreeing that it was their role to refer PWID to health and social programs had higher odds of reporting such referrals (aOR: 3.32, 95% CI: 2.52-4.37). Legal knowledge was not associated with these practices. Changing drug policy and knowledge may be insufficient in shifting police behavior. Modifying officers' occupational risks and attitudes towards harm reduction interventions can facilitate efforts to align police practices with PWID health. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. [A network of LIFE projects to promote the transfer and exchange of knowledge on environment and health].

    PubMed

    Cori, Liliana; Carducci, Annalaura; Donzelli, Gabriele; La Rocca, Cinzia; Bianchi, Fabrizio

    2018-01-01

    Eleven projects within the LIFE programme (through which the Directorate-General for Environment of the European Commission provides funding for projects aim at protecting environment and nature) addressing environmental-health-related issues have been involved in a collaborative network called KTE LIFE EnvHealth Network. The shared issues tackled by that projects are knowledge transfer and exchange (KTE). The objective of the LIFE programme is to support the implementation of the environmental legislation in the European Union, to provide new tools and knowledge that will help to better protect both the territory and the communities. Transferring knowledge to decision makers, at the appropriate and effective level, is therefore a central function of the projects. The Network promotes national and international networking, which intends to involve other projects, to provide methodological support, to make information and successful practices circulate, with the aim of multiplying the energies of each project involved.

  1. Prevalence and correlates of needle-stick injuries among active duty police officers in Tijuana, Mexico

    PubMed Central

    Mittal, María Luisa; Beletsky, Leo; Patiño, Efraín; Abramovitz, Daniela; Rocha, Teresita; Arredondo, Jaime; Bañuelos, Arnulfo; Rangel, Gudelia; Strathdee, Steffanie A

    2016-01-01

    Introduction Police officers are at an elevated risk for needle-stick injuries (NSI), which pose a serious and costly occupational health risk for HIV and viral hepatitis. However, research on NSIs among police officers is limited, especially in low- and middle-income countries. Despite the legality of syringe possession in Mexico, half of people who inject drugs (PWID) in Tijuana report extrajudicial syringe-related arrests and confiscation by police, which has been associated with needle-sharing and HIV infection. We assessed the prevalence and correlates of NSIs among Tijuana police officers to inform efforts to improve occupational safety and simultaneously reduce HIV risks among police and PWID. Methods Tijuana's Department of Municipal Public Safety (SSPM) is among Mexico's largest. Our binational, multi-sectoral team analyzed de-identified data from SSPM's 2014 anonymous self-administered occupational health survey. The prevalence of NSI and syringe disposal practices was determined. Logistic regression with robust variance estimation via generalized estimating equations identified factors associated with ever having an occupational NSI. Results Approximately one-quarter of the Tijuana police force was given the occupational health survey (N=503). Respondents were predominantly male (86.5%) and ≤35 years old (42.6%). Nearly one in six officers reported ever having a NSI while working at SSPM (15.3%), of whom 14.3% reported a NSI within the past year. Most participants reported encountering needles/syringes while on duty (n=473, 94%); factors independently associated with elevated odds of NSIs included frequently finding syringes that contain drugs (adjusted odds ratio (AOR): 2.98; 95% confidence interval (CI): 1.56–5.67) and breaking used needles (AOR: 2.25; 95% CI: 1.29–3.91), while protective factors included being willing to contact emergency services in case of NSIs (AOR: 0.39; 95% CI: 0.22–0.69), and wearing needle-stick resistant gloves (AOR: 0.43; 95% CI: 0.19–0.91). Conclusions Tijuana police face an elevated and unaddressed occupational NSI burden associated with unsafe syringe-handling practices, exposing them to substantial risk of HIV and other blood-borne infections. These findings spurred the development and tailoring of training to reduce NSI by modifying officer knowledge, attitudes and enforcement practices (e.g. syringe confiscation) – factors that also impact HIV transmission among PWID and other members of the community. PMID:27435711

  2. Elementary students' multiple representations of their ideas about air

    NASA Astrophysics Data System (ADS)

    Gravel, Brian Edward

    This dissertation explores how students generate multiple external representations of their ideas about air, an "invisible" substance. External representations can serve a powerful role in placing students' ideas into the external world for reflection and abstraction. When provided the opportunity to represent their understandings of science in different ways, students generate increasingly coherent explanations of what they observe, including developing ideas about mechanisms that describe cause and effect. In this qualitative study, extended clinical interviews were conducted with twelve fifth-grade students from an urban public charter school. In study was designed to investigate students' ideas about air in the context of a linked-syringe device with the support of multiple representations. Students were given the opportunity to produce representations and to offer verbal explanations of the behavior of the syringes in a sequence of three interviews. In the first session, students were introduced to the linked-syringes, and they generated drawings to explain their thinking about air. In the second session, students created stop-motion animations of their explanations for air in the syringes. And in the final session, students built physical devices to demonstrate their ideas about air. Careful analysis of each individual student's trajectory through the microgenetic design and a cross-student analysis reveal that the process of generating multiple representations facilitates how students think and reason about air. Drawings served to organize elements of the linked-syringe problem, providing students with focal points on which to direct their reasoning as they generated more precise explanations. Stop-motion animation supported students' efforts to make sense of processes that change over time, such as compressing the air inside the syringes. And, the construction of physical artifacts prompted students to think about air as a substance, as the activity allowed them to generate analogous physical models of the linked syringes. Furthermore, the students' productions provided the researcher with enhanced access to the substance of students' ideas as captured in their representations. The results of this study are presented in case-study form to highlight how representations serve as embodiments of the resources that students possess for making sense of science. This dissertation contributes to the resources perspective of the importance of external representations in students' development of coherent explanations of what they observe.

  3. Chemical Stability of Morphine, Ropivacaine, and Ziconotide in Combination for Intrathecal Analgesia.

    PubMed

    Robert, Julien; Sorrieul, Jérémy; Rossignol, Elsa; Beaussart, Hélène; Kieffer, Hélène; Folliard, Caroline; Dupoiron, Denis; Devys, Catherine

    2017-01-01

    Pain is the most feared symptom amongst individuals living with cancer. In 15% to 20% of patients, conventional analgesic therapy either fails to relieve pain or induces adverse effects. Intrathecal drug delivery systems may present an effective alternative for pain management. The Cancerology Center Paul Papin protocol includes an admixture of morphine, ropivacaine, and ziconotide in intrathecal preparations. These drugs are administered by a fully implantable or an external pump. Syringes or polyolefin infusion bags are prepared for refill just before use. Few centers in France use the method of intrathecal analgesia. Therefore, for those patients receiving intrathecal preparations, each filling requires that the patients be transported from their local hospital (or their home) to a referral center where the patients are monitored. They sometimes must travel up to a hundred kilometers to have a pump filled. The preparation and the analytical control of the mixture are carried out only by those centers meeting the proper criteria, which includes the proper equipment. To spare the patient this travel, a peripheral center may be subcontracted to manage the patient's pump refill. No data are available concerning the chemical stability of admixtures in syringes or polyolefin infusion bags. The aim of this study was to evaluate, with a new analytical method using ultra high-performance liquid chromatography, the chemical stability of these admixtures in syringes or in polyolefin infusion bags. Ziconotide 1 µg/mL was combined with ropivacaine (7.5 mg/mL) and morphine (3.5 mg/mL) in syringes at 5°C, 21°C, and 31°C, and in polyolefin infusion bags at 21°C. Assays were performed using ultra high-pressure liquid chromatography. In syringes stored at 21°C and 31°C, concentrations after 6 hours were not in the acceptable criterion of 10% variability. When syringes were stored at 5°C, the residual concentration of ziconotide after 3 days was 100.5% +/- 2.6% [92.7% to 108.4%]. In polyolefin infusion bags, the residual concentration of ziconotide after 14 days was 96.9% +/- 2.2% [90.1% to 103.6%]. This study demonstrates the chemical stability of this admixture in syringes stored at 5°C for 3 days and in polyolefin plastibags stored at 21°C for 14 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  4. Prevalence and correlates of needle-stick injuries among active duty police officers in Tijuana, Mexico.

    PubMed

    Mittal, María Luisa; Beletsky, Leo; Patiño, Efraín; Abramovitz, Daniela; Rocha, Teresita; Arredondo, Jaime; Bañuelos, Arnulfo; Rangel, Gudelia; Strathdee, Steffanie A

    2016-01-01

    Police officers are at an elevated risk for needle-stick injuries (NSI), which pose a serious and costly occupational health risk for HIV and viral hepatitis. However, research on NSIs among police officers is limited, especially in low- and middle-income countries. Despite the legality of syringe possession in Mexico, half of people who inject drugs (PWID) in Tijuana report extrajudicial syringe-related arrests and confiscation by police, which has been associated with needle-sharing and HIV infection. We assessed the prevalence and correlates of NSIs among Tijuana police officers to inform efforts to improve occupational safety and simultaneously reduce HIV risks among police and PWID. Tijuana's Department of Municipal Public Safety (SSPM) is among Mexico's largest. Our binational, multi-sectoral team analyzed de-identified data from SSPM's 2014 anonymous self-administered occupational health survey. The prevalence of NSI and syringe disposal practices was determined. Logistic regression with robust variance estimation via generalized estimating equations identified factors associated with ever having an occupational NSI. Approximately one-quarter of the Tijuana police force was given the occupational health survey (N=503). Respondents were predominantly male (86.5%) and ≤35 years old (42.6%). Nearly one in six officers reported ever having a NSI while working at SSPM (15.3%), of whom 14.3% reported a NSI within the past year. Most participants reported encountering needles/syringes while on duty (n=473, 94%); factors independently associated with elevated odds of NSIs included frequently finding syringes that contain drugs (adjusted odds ratio (AOR): 2.98; 95% confidence interval (CI): 1.56-5.67) and breaking used needles (AOR: 2.25; 95% CI: 1.29-3.91), while protective factors included being willing to contact emergency services in case of NSIs (AOR: 0.39; 95% CI: 0.22-0.69), and wearing needle-stick resistant gloves (AOR: 0.43; 95% CI: 0.19-0.91). Tijuana police face an elevated and unaddressed occupational NSI burden associated with unsafe syringe-handling practices, exposing them to substantial risk of HIV and other blood-borne infections. These findings spurred the development and tailoring of training to reduce NSI by modifying officer knowledge, attitudes and enforcement practices (e.g. syringe confiscation) - factors that also impact HIV transmission among PWID and other members of the community.

  5. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jennings, G

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber andmore » a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.« less

  6. Micro-Organ Device

    NASA Technical Reports Server (NTRS)

    Sun, Wei (Inventor); Chang, Robert C. (Inventor); Starly, Binil (Inventor); Holtorf, Heidi L. (Inventor); Leslie, Julia (Inventor); Culbertson, Christopher (Inventor); Gonda, Steve R. (Inventor)

    2013-01-01

    A method for fabricating a micro-organ device comprises providing a microscale support having one or more microfluidic channels and one or more micro-chambers for housing a micro-organ and printing a micro-organ on the microscale support using a cell suspension in a syringe controlled by a computer-aided tissue engineering system, wherein the cell suspension comprises cells suspended in a solution containing a material that functions as a three-dimensional scaffold. The printing is performed with the computer-aided tissue engineering system according to a particular pattern. The micro-organ device comprises at least one micro-chamber each housing a micro-organ; and at least one microfluidic channel connected to the micro-chamber, wherein the micro-organ comprises cells arranged in a configuration that includes microscale spacing between portions of the cells to facilitate diffusion exchange between the cells and a medium supplied from the at least one microfluidic channel.

  7. Micro-organ device

    NASA Technical Reports Server (NTRS)

    von Gustedt-Gonda, legal representative, Iris (Inventor); Holtorf, Heidi L. (Inventor); Gonda, Steve R. (Inventor); Leslie, Julia (Inventor); Chang, Robert C. (Inventor); Sun, Wei (Inventor); Starly, Binil (Inventor); Culbertson, Christopher (Inventor)

    2013-01-01

    A method for fabricating a micro-organ device comprises providing a microscale support having one or more microfluidic channels and one or more micro-chambers for housing a micro-organ and printing a micro-organ on the microscale support using a cell suspension in a syringe controlled by a computer-aided tissue engineering system, wherein the cell suspension comprises cells suspended in a solution containing a material that functions as a three-dimensional scaffold. The printing is performed with the computer-aided tissue engineering system according to a particular pattern. The micro-organ device comprises at least one micro-chamber each housing a micro-organ; and at least one microfluidic channel connected to the micro-chamber, wherein the micro-organ comprises cells arranged in a configuration that includes microscale spacing between portions of the cells to facilitate diffusion exchange between the cells and a medium supplied from the at least one microfluidic channel.

  8. DNA Assembly in 3D Printed Fluidics

    PubMed Central

    Patrick, William G.; Nielsen, Alec A. K.; Keating, Steven J.; Levy, Taylor J.; Wang, Che-Wei; Rivera, Jaime J.; Mondragón-Palomino, Octavio; Carr, Peter A.; Voigt, Christopher A.; Oxman, Neri; Kong, David S.

    2015-01-01

    The process of connecting genetic parts—DNA assembly—is a foundational technology for synthetic biology. Microfluidics present an attractive solution for minimizing use of costly reagents, enabling multiplexed reactions, and automating protocols by integrating multiple protocol steps. However, microfluidics fabrication and operation can be expensive and requires expertise, limiting access to the technology. With advances in commodity digital fabrication tools, it is now possible to directly print fluidic devices and supporting hardware. 3D printed micro- and millifluidic devices are inexpensive, easy to make and quick to produce. We demonstrate Golden Gate DNA assembly in 3D-printed fluidics with reaction volumes as small as 490 nL, channel widths as fine as 220 microns, and per unit part costs ranging from $0.61 to $5.71. A 3D-printed syringe pump with an accompanying programmable software interface was designed and fabricated to operate the devices. Quick turnaround and inexpensive materials allowed for rapid exploration of device parameters, demonstrating a manufacturing paradigm for designing and fabricating hardware for synthetic biology. PMID:26716448

  9. [How to assess and reduce social inequalities in cancer screening programmes].

    PubMed

    Binefa, Gemma; García, Montse; Peiró, Rosana; Molina-Barceló, Ana; Ibáñez, Raquel

    2016-01-01

    This field note presents the conclusions and recommendations made at the meeting 'How to reduce social inequalities in cancer screening programmes?' held at the XXVI School of Public Health of Mahon (Menorca, Spain). Participants developed recommendations based on experiences of population-based screening programmes (breast and colorectal) and opportunistic screening (cervical). The conclusions and recommendations focused on four main areas (information systems, evaluation and quality, research, and interventions): the inclusion of social variables at an individual level in health information systems; the establishment of minimum standards for gathering information regarding inequalities in access to preventive services; the performance of actions in vulnerable populations; and the promotion of the exchange of experiences and best practices through the Cancer Screening Programmes Network and working groups of the scientific societies. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  10. Exercise-based cardiac rehabilitation in twelve European countries results of the European cardiac rehabilitation registry.

    PubMed

    Benzer, Werner; Rauch, Bernhard; Schmid, Jean-Paul; Zwisler, Ann Dorthe; Dendale, Paul; Davos, Constantinos H; Kouidi, Evangelia; Simon, Attila; Abreu, Ana; Pogosova, Nana; Gaita, Dan; Miletic, Bojan; Bönner, Gerd; Ouarrak, Taoufik; McGee, Hannah

    2017-02-01

    Results from EuroCaReD study should serve as a benchmark to improve guideline adherence and treatment quality of cardiac rehabilitation (CR) in Europe. Data from 2.054 CR patients in 12 European countries were derived from 69 centres. 76% were male. Indication for CR differed between countries being predominantly ACS in Switzerland (79%), Portugal (62%) and Germany (61%), elective PCI in Greece (37%), Austria (36%) and Spain (32%), and CABG in Croatia and Russia (36%). A minority of patients presented with chronic heart failure (4%). At CR start, most patients already were under medication according to current guidelines for the treatment of CV risk factors. A wide range of CR programme designs was found (duration 3 to 24weeks; total number of sessions 30 to 196). Patient programme adherence after admission was high (85%). With reservations that eCRF follow-up data exchange remained incomplete, patient CV risk profiles experienced only small improvements. CR success as defined by an increase of exercise capacity >25W was significantly higher in young patients and those who were employed. Results differed by countries. After CR only 9% of patients were admitted to a structured post-CR programme. Clinical characteristics of CR patients, indications and programmes in Europe are different. Guideline adherence is poor. Thus, patient selection and CR programme designs should become more evidence-based. Routine eCRF documentation of CR results throughout European countries was not sufficient in its first application because of incomplete data exchange. Therefore better adherence of CR centres to minimal routine clinical standards is requested. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. INFOMAR - Ireland's National Seabed Mapping Programme: A Tool For Marine Spatial Planning

    NASA Astrophysics Data System (ADS)

    Furey, T. M.

    2016-02-01

    INFOMAR is Ireland's national seabed mapping programme and is a key action in the national integrated marine plan, Harnessing Our Ocean Wealth. It comprises a multi-platform approach to delivering marine integrated mapping in 2 phases, over a projected 20 year timeline (2006-2026). The programme has three work strands; Data Acquisition, Data Exchange and Integration, and Value Added Exploitation. The Data Acquisition strand includes collection of hydrographic, oceanographic, geological, habitat and heritage datasets that will underpin future sustainable development and management of Ireland's marine resource. INFOMAR outputs are delivered through the Data Exchange and Integration strand. Uses of these outputs are wide ranging and multipurpose, from management plans for fisheries, aquaculture and coastal protection works, to environmental impact assessments, ocean renewable development and integrated coastal zone management. In order to address the evolution and diversification of maritime user requirements, the programme has realigned and developed outputs and new products, in part, through an innovative research funding initiative. Development is also fostered through the Value Added Exploitation strand. INFOMAR outputs and products serve to underpin delivery of Ireland's statutory obligations and enhance compliance with EU and national legislation. This is achieved through co-operation with the agencies responsible for supporting Ireland's international obligations and for the implementation of marine spatial planning. A strategic national seabed mapping programme such as INFOMAR, provides a critical baseline dataset which underpins development of the marine economy, and improves our understanding of the response of marine systems to pressures, and the effect of cumulative impacts. This paper will focus on the evolution and scope of INFOMAR, and look at examples of outputs being harnessed to serve approaches to the management of activities having an impact on the marine environment.

  12. Designing Energy-Efficient Heat Exchangers--- Creating Micro-Channels on the Aluminum Fin Surface

    NASA Astrophysics Data System (ADS)

    Ying, Jia; Sommers, Andrew; Eid, Khalid

    2010-03-01

    In this research, a method for patterning micro-channels on aluminum surfaces is described for the purpose of exploiting those features to affect the surface wettability. Minimizing water retention on aluminum is important in the design of energy-efficient heat exchangers because water retention can deteriorate the performance of such devices. It increases the air-side pressure drop and can decrease the sensible heat transfer coefficient thereby increasing energy consumption and contributing to higher pollution levels in the environment. Photolithography is used to create the micro-scale channels and a hydrophobic polymer is used to reduce the surface energy of the aluminum plates. Droplets are both injected on the surface using a micro-syringe and condensed on the surface using an environmentally-controlled chamber. A ram'e-hart goniometer is used to determine the advancing and receding contact angles of water droplets on these modified surfaces, and a tilt-table assembly is used to measure the critical inclination angle for sliding. Our results show that droplets placed on these patterned surfaces not only have significantly lower critical inclination angles for sliding but are easier to remove from the surface at low air flow rates. Efforts to model the onset of droplet movement on these surfaces using a simple force balance relationship are currently underway.

  13. Rise in needle sharing among injection drug users in Pakistan during the Afghanistan war.

    PubMed

    Strathdee, Steffanie A; Zafar, Tariq; Brahmbhatt, Heena; Baksh, Ahmed; ul Hassan, Salman

    2003-07-20

    The war in Afghanistan in 2001 may have had direct or indirect effects on drug users' behaviors in nearby Pakistan. We studied drug use patterns and correlates of needle sharing among injection drug users (IDUs) in Lahore, Pakistan, before and after the beginning of the Afghanistan war. Between August and October 2001, 244 drug users registering for needle exchange and other services underwent an interviewer-administered survey on sociodemographics, drug use and HIV/AIDS awareness. chi(2)-tests were used to compare drug use behaviors among subjects interviewed before and after October 6th, 2001, coinciding with the start of the Afghanistan war. Correlates of needle sharing among IDUs were identified using logistic regression. Comparing IDUs interviewed before and after October 6th, 2001, levels of needle sharing were significantly higher after the war (56% versus 76%, respectively; P=0.02). Factors independently associated with needle sharing included registering after the war began (adjusted odds ratio, AOR=3.76 (95% CI: 1.23-11.48)), being married (AOR=0.36), being homeless (AOR=3.91), having been arrested (AOR=6.00), and re-using syringes (AOR=6.19). Expansion of needle exchange, drug treatment and supportive services is urgently needed to avoid an explosive HIV epidemic in Pakistan.

  14. Police Encounters Among Needle Exchange Clients in Baltimore: Drug Law Enforcement as a Structural Determinant of Health

    PubMed Central

    Cochrane, Jess; Sawyer, Anne L.; Serio-Chapman, Chris; Smelyanskaya, Marina; Han, Jennifer; Robinowitz, Natanya; Sherman, Susan G.

    2015-01-01

    Objectives. We piloted a monitoring mechanism to document police encounters around programs targeting people who inject drugs (PWID), and assessed their demographic predictors at 2 Baltimore, Maryland, needle exchange program (NEP) sites. Methods. In a brief survey, 308 clients quantified, characterized, and sited recent police encounters. Multivariate linear regression determined encounter predictors, and we used geocoordinate maps to illustrate clusters. Results. Within the past 6 months, clients reported a median of 3 stops near NEP sites (interquartile range [IQR] = 0–7.5) and a median of 1 arrest in any location (IQR = 0–2). Three respondents reported police referral to the NEP. Being younger (P = .009), being male (P = .033), and making frequent NEP visits (P = .02) were associated with reported police stops. Among clients reporting arrest or citation for syringe possession, Whites were significantly less likely than non-Whites to report being en route to or from an NEP (P < .001). Reported encounters were clustered around NEPs. Conclusions. Systematic surveillance of structural determinants of health for PWID proved feasible when integrated into service activities. Improved monitoring is critical to informing interventions to align policing with public health, especially among groups subject to disproportionate levels of drug law enforcement. PMID:26180948

  15. Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.

    PubMed

    Kim, Do-Yeon; Robergs, Robert Andrew

    2012-02-01

    Limited validation research exists for applications of breath-by-breath systems of expired gas analysis indirect calorimetry (EGAIC) during exercise. We developed improved hardware and software for breath-by-breath indirect calorimetry (NEW) and validated this system as well as a commercial system (COM) against 2 methods: (i) mechanical ventilation with known calibration gas, and (ii) human subjects testing for 5 min each at rest and cycle ergometer exercise at 100 and 175 W. Mechanical calibration consisted of medical grade and certified calibration gas ((4.95% CO(2), 12.01% O(2), balance N(2)), room air (20.95% O(2), 0.03% CO(2), balance N(2)), and 100% nitrogen), and an air flow turbine calibrated with a 3-L calibration syringe. Ventilation was mimicked manually using complete 3-L calibration syringe manouvers at a rate of 10·min(-1) from a Douglas bag reservoir of calibration gas. The testing of human subjects was completed in a counterbalanced sequence based on 5 repeated tests of all conditions for a single subject. Rest periods of 5 and 10 min followed the 100 and 175 W conditions, respectively. COM and NEW had similar accuracy when tested with known ventilation and gas fractions. However, during human subjects testing COM significantly under-measured carbon dioxide gas fractions, over-measured oxygen gas fractions and minute ventilation, and resulted in errors to each of oxygen uptake, carbon dioxide output, and respiratory exchange ratio. These discrepant findings reveal that controlled ventilation and gas fractions are insufficient to validate breath-by-breath, and perhaps even time-averaged, systems of EGAIC. The errors of the COM system reveal the need for concern over the validity of commercial systems of EGAIC.

  16. Rapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis system.

    PubMed

    Almeida, S A A; Amorim, L R; Heitor, A H; Montenegro, M C B S M; Barbosa, J; Sá, L C; Sales, M G F

    2011-12-01

    Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% o-nitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade(-1) down to 1.0 × 10(-5) mol L(-1), with a limit of detection of 3.1 × 10(-6) mol L(-1) in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography-tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

  17. Reconciling incongruous qualitative and quantitative findings in mixed methods research: exemplars from research with drug using populations.

    PubMed

    Wagner, Karla D; Davidson, Peter J; Pollini, Robin A; Strathdee, Steffanie A; Washburn, Rachel; Palinkas, Lawrence A

    2012-01-01

    Mixed methods research is increasingly being promoted in the health sciences as a way to gain more comprehensive understandings of how social processes and individual behaviours shape human health. Mixed methods research most commonly combines qualitative and quantitative data collection and analysis strategies. Often, integrating findings from multiple methods is assumed to confirm or validate the findings from one method with the findings from another, seeking convergence or agreement between methods. Cases in which findings from different methods are congruous are generally thought of as ideal, whilst conflicting findings may, at first glance, appear problematic. However, the latter situation provides the opportunity for a process through which apparently discordant results are reconciled, potentially leading to new emergent understandings of complex social phenomena. This paper presents three case studies drawn from the authors' research on HIV risk amongst injection drug users in which mixed methods studies yielded apparently discrepant results. We use these case studies (involving injection drug users [IDUs] using a Needle/Syringe Exchange Program in Los Angeles, CA, USA; IDUs seeking to purchase needle/syringes at pharmacies in Tijuana, Mexico; and young street-based IDUs in San Francisco, CA, USA) to identify challenges associated with integrating findings from mixed methods projects, summarize lessons learned, and make recommendations for how to more successfully anticipate and manage the integration of findings. Despite the challenges inherent in reconciling apparently conflicting findings from qualitative and quantitative approaches, in keeping with others who have argued in favour of integrating mixed methods findings, we contend that such an undertaking has the potential to yield benefits that emerge only through the struggle to reconcile discrepant results and may provide a sum that is greater than the individual qualitative and quantitative parts. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Reconciling incongruous qualitative and quantitative findings in mixed methods research: exemplars from research with drug using populations

    PubMed Central

    Wagner, Karla D.; Davidson, Peter J.; Pollini, Robin A.; Strathdee, Steffanie A.; Washburn, Rachel; Palinkas, Lawrence A.

    2011-01-01

    Mixed methods research is increasingly being promoted in the health sciences as a way to gain more comprehensive understandings of how social processes and individual behaviours shape human health. Mixed methods research most commonly combines qualitative and quantitative data collection and analysis strategies. Often, integrating findings from multiple methods is assumed to confirm or validate the findings from one method with the findings from another, seeking convergence or agreement between methods. Cases in which findings from different methods are congruous are generally thought of as ideal, while conflicting findings may, at first glance, appear problematic. However, the latter situation provides the opportunity for a process through which apparently discordant results are reconciled, potentially leading to new emergent understandings of complex social phenomena. This paper presents three case studies drawn from the authors’ research on HIV risk among injection drug users in which mixed methods studies yielded apparently discrepant results. We use these case studies (involving injection drug users [IDUs] using a needle/syringe exchange program in Los Angeles, California, USA; IDUs seeking to purchase needle/syringes at pharmacies in Tijuana, Mexico; and young street-based IDUs in San Francisco, CA, USA) to identify challenges associated with integrating findings from mixed methods projects, summarize lessons learned, and make recommendations for how to more successfully anticipate and manage the integration of findings. Despite the challenges inherent in reconciling apparently conflicting findings from qualitative and quantitative approaches, in keeping with others who have argued in favour of integrating mixed methods findings, we contend that such an undertaking has the potential to yield benefits that emerge only through the struggle to reconcile discrepant results and may provide a sum that is greater than the individual qualitative and quantitative parts. PMID:21680168

  19. Implementation Study of Patient-Ready Syringes Containing 25 mg/mL Methotrexate Solution for Use in Treating Ectopic Pregnancy

    PubMed Central

    Respaud, R.; Gaudy, A. S.; Arlicot, C.; Tournamille, J. F.; Viaud-Massuard, M. C.; Elfakir, C.; Antier, D.

    2014-01-01

    Background. Ectopic pregnancy (EP) is a significant cause of morbidity and mortality during the first trimester of pregnancy. Small unruptured tubal pregnancies can be treated medically with a single dose of methotrexate (MTX). Objective. The aim of this study was to evaluate the stability of a 25 mg/mL solution of MTX to devise a secure delivery circuit for the preparation and use of this medication in the management of EP. Method. MTX solutions were packaged in polypropylene syringes, stored over an 84-day period, and protected from light either at +2 to +8°C or at 23°C. We assessed the physical and chemical stability of the solutions at various time points over the storage period. A pharmaceutical delivery circuit was implemented that involved the batch preparation of MTX syringes. Results. We show that 25 mg/mL MTX solutions remain stable over an 84-day period under the storage conditions tested. Standard doses were prepared, ranging from 50 mg to 100 mg. The results of this study suggest that MTX syringes can be prepared in advance by the pharmacy, ready to be dispensed at any time that a diagnosis of EP is made. Conclusion. The high stability of a 25 mg/mL MTX solution in polypropylene syringes makes it possible to implement a flexible and cost-effective delivery circuit for ready-to-use preparations of this drug, providing 24-hour access and preventing treatment delays. PMID:24900977

  20. "Vivo para consumirla y la consumo para vivir" ["I live to inject and inject to live"]: high-risk injection behaviors in Tijuana, Mexico.

    PubMed

    Strathdee, Steffanie A; Fraga, Wendy Davila; Case, Patricia; Firestone, Michelle; Brouwer, Kimberly C; Perez, Saida Gracia; Magis, Carlos; Fraga, Miguel Angel

    2005-09-01

    Injection drug use is a growing problem on the US-Mexico border, where Tijuana is situated. We studied the context of injection drug use among injection drug users (IDUs) in Tijuana to help guide future research and interventions. Guided in-depth interviews were conducted with 10 male and 10 female current IDUs in Tijuana. Topics included types of drug used, injection settings, access to sterile needles, and environmental influences. Interviews were taped, transcribed verbatim, and translated. Content analysis was conducted to identify themes. Of the 20 IDUs, median age and age at first injection were 30 and 18. Most reported injecting at least daily: heroin ("carga", "chiva", "negra"), methamphetamine ("crico", "cri-cri"), or both drugs combined. In sharp contrast to Western US cities, almost all regularly attended shooting galleries ("yongos" or "picaderos") because of the difficulties obtaining syringes and police oppression. Almost all shared needles/paraphernalia ["cuete" (syringe), "cacharros" (cookers), cotton from sweaters/socks (filters)]. Some reported obtaining syringes from the United States. Key themes included (1) pharmacies refusing to sell or charging higher prices to IDUs, (2) ample availability of used/rented syringes from "picaderos" (e.g., charging approximately 5 pesos or "10 drops" of drug), and (3) poor HIV/AIDS knowledge, such as beliefs that exposing syringes to air "kills germs." This qualitative study suggests that IDUs in Tijuana are at high risk of HIV and other blood-borne infections. Interventions are urgently needed to expand access to sterile injection equipment and offset the potential for a widespread HIV epidemic.

Top