Sample records for system diagnostic active

  1. Enhanced NIF neutron activation diagnostics.

    PubMed

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  2. A modern diagnostic approach for automobile systems condition monitoring

    NASA Astrophysics Data System (ADS)

    Selig, M.; Shi, Z.; Ball, A.; Schmidt, K.

    2012-05-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  3. Diagnostic value of creatine kinase activity in canine cerebrospinal fluid.

    PubMed

    Ferreira, Alexandra

    2016-10-01

    This study aimed to determine whether creatine kinase (CK) activity in cerebrospinal fluid (CSF) has diagnostic value for various groups of neurological conditions or for different anatomical areas of the nervous system (NS). The age, breed, results of CSF analysis, and diagnosis of 578 canine patients presenting with various neurological conditions between January 2009 and February 2015 were retrospectively collected. The cases were divided according to anatomical areas of the nervous system, i.e., brain, spinal cord, and peripheral nervous system, and into groups according to the nature of the condition diagnosed: vascular, immune/inflammatory/infectious, traumatic, toxic, anomalous, metabolic, idiopathic, neoplastic, and degenerative. Statistical analysis showed that CSF-CK alone cannot be used as a diagnostic tool and that total proteins in the CSF and red blood cells (RBCs) do not have a significant relationship with the CSF-CK activity. CSF-CK did not have a diagnostic value for different disease groups or anatomical areas of the nervous system.

  4. Teacher's Psycho-Diagnostic Activities in School Educational System

    ERIC Educational Resources Information Center

    Minakhmetova, Albina Z.; Pyanova, Ekaterina N.; Akhmetshina, Enze M.

    2016-01-01

    The urgency of the problem stated in the article stems from the fact that in modern conditions the study of the psycho-diagnostic component of the teacher's activities is relevant in practical terms, since the functions of these activities affect the efficiency of pedagogical activity and the educational process itself, including the effectiveness…

  5. Electromagnetic Analysis of ITER Diagnostic Equatorial Port Plugs During Plasma Disruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Y. Zhai, R. Feder, A. Brooks, M. Ulrickson, C.S. Pitcher and G.D. Loesser

    2012-08-27

    ITER diagnostic port plugs perform many functionsincluding structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs), Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less

  6. Coagulation cascade and complement system in systemic lupus erythematosus

    PubMed Central

    Liang, Yan; Xie, Shang-Bo; Wu, Chang-Hao; Hu, Yuan; Zhang, Qin; Li, Si; Fan, Yin-Guang; Leng, Rui-Xue; Pan, Hai-Feng; Xiong, Hua-Bao; Ye, Dong-Qing

    2018-01-01

    This study was conducted to (1) characterize coagulation cascade and complement system in systemic lupus erythematosus (SLE); (2) evaluate the associations between coagulation cascade, complement system, inflammatory response and SLE disease severity; (3) test the diagnostic value of a combination of D-dimer and C4 for lupus activity. Transcriptomics, proteomics and metabolomics were performed in 24 SLE patients and 24 healthy controls. The levels of ten coagulations, seven complements and three cytokines were measured in 112 SLE patients. Clinical data were collected from 2025 SLE patients. The analysis of multi-omics data revealed the common links for the components of coagulation cascade and complement system. The results of ELISA showed coagulation cascade and complement system had an interaction effect on SLE disease severity, this effect was pronounced among patients with excess inflammation. The analysis of clinical data revealed a combination of D-dimer and C4 provided good diagnostic performance for lupus activity. This study suggested that coagulation cascade and complement system become ‘partners in crime’, contributing to SLE disease severity and identified the diagnostic value of D-dimer combined with C4for lupus activity. PMID:29599912

  7. RANZCR Body Systems Framework of diagnostic imaging examination descriptors.

    PubMed

    Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia

    2014-08-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.

  8. [A new information technology for system diagnosis of functional activity of human organs].

    PubMed

    Avshalumov, A Sh; Sudakov, K V; Filaretov, G F

    2006-01-01

    The goal of this work was to consider a new diagnostic technology based on analysis of objective information parameters of functional activity and interaction of normal and pathologically changed human organs. The technology is based on the use of very low power millimeter (EHF) radiation emitted by human body and other biological objects in the process of vital activity. The importance of consideration of the information aspect of vital activity from the standpoint of the theory of functional systems suggested by P. K. Anokhin is emphasized. The suggested information technology is theoretically substantiated. The capabilities of the suggested technology for diagnosis, as well as the difficulties of its practical implementation caused by very low power of electromagnetic fields generated by human body, are discussed. It is noted that only use of modern radiophysical equipment together with new software based on specially developed algorithms made it possible to construct a medical EHF diagnostic system for effective implementation of the suggested technology. The system structure, functions of its components, the examination procedure, and the form of representation of diagnostic information are described together with the specific features of applied software based on the principle of maximal objectivity of analysis and interpretation of the results of diagnosis on the basis of artificial intelligence algorithms. The diagnostic capabilities of the system are illustrated by several examples.

  9. Improved Signal Processing Technique Leads to More Robust Self Diagnostic Accelerometer System

    NASA Technical Reports Server (NTRS)

    Tokars, Roger; Lekki, John; Jaros, Dave; Riggs, Terrence; Evans, Kenneth P.

    2010-01-01

    The self diagnostic accelerometer (SDA) is a sensor system designed to actively monitor the health of an accelerometer. In this case an accelerometer is considered healthy if it can be determined that it is operating correctly and its measurements may be relied upon. The SDA system accomplishes this by actively monitoring the accelerometer for a variety of failure conditions including accelerometer structural damage, an electrical open circuit, and most importantly accelerometer detachment. In recent testing of the SDA system in emulated engine operating conditions it has been found that a more robust signal processing technique was necessary. An improved accelerometer diagnostic technique and test results of the SDA system utilizing this technique are presented here. Furthermore, the real time, autonomous capability of the SDA system to concurrently compensate for effects from real operating conditions such as temperature changes and mechanical noise, while monitoring the condition of the accelerometer health and attachment, will be demonstrated.

  10. Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Y

    2014-03-03

    ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less

  11. Expert Systems and Diagnostic Monitors in Psychiatry

    PubMed Central

    Gelernter, David; Gelernter, Joel

    1984-01-01

    We argue that existing expert systems for medical diagnosis have not satisfactorily addressed an important problem: how are such systems to be integrated into the clinical environment? This problem should be addressed before and not after a working system is developed, because its solution might well determine important aspects of the ultimate system structure. We propose as one solution the online diagnostic monitor, which is a diagnostic expert system designed for interactive use by a clinican during the course of a patient interview. The exchange between a diagnostic monitor and its clinican user is guided by the user, not the system, and the monitor functions as a passive advisor rather than an active decision-maker. We discuss why a system of this sort might be particularly well-suited to psychiatric diagnosis, and describe preliminary work on an experimental prototype.

  12. Evaluating the Diagnostic Validity of a Facet-Based Formative Assessment System

    ERIC Educational Resources Information Center

    DeBarger, Angela Haydel; DiBello, Louis; Minstrell, Jim; Feng, Mingyu; Stout, William; Pellegrino, James; Haertel, Geneva; Harris, Christopher; Ructinger, Liliana

    2011-01-01

    This paper describes methods for an alignment study and psychometric analyses of a formative assessment system, Diagnoser Tools for physics. Diagnoser Tools begin with facet clusters as the interpretive framework for designing questions and instructional activities. Thus each question in the diagnostic assessments includes distractors that…

  13. Crack identification for reinforced concrete using PZT based smart rebar active sensing diagnostic network

    NASA Astrophysics Data System (ADS)

    Song, N. N.; Wu, F.

    2016-04-01

    An active sensing diagnostic system using PZT based smart rebar for SHM of RC structure has been currently under investigation. Previous test results showed that the system could detect the de-bond of concrete from reinforcement, and the diagnostic signals were increased exponentially with the de-bonding size. Previous study also showed that the smart rebar could function well like regular reinforcement to undertake tension stresses. In this study, a smart rebar network has been used to detect the crack damage of concrete based on guided waves. Experimental test has been carried out for the study. In the test, concrete beams with 2 reinforcements have been built. 8 sets of PZT elements were mounted onto the reinforcement bars in an optimized way to form an active sensing diagnostic system. A 90 kHz 5-cycle Hanning-windowed tone burst was used as input. Multiple cracks have been generated on the concrete structures. Through the guided bulk waves propagating in the structures from actuators and sensors mounted from different bars, crack damage could be detected clearly. Cases for both single and multiple cracks were tested. Different crack depths from the surface and different crack numbers have been studied. Test result shows that the amplitude of sensor output signals is deceased linearly with a propagating crack, and is decreased exponentially with increased crack numbers. From the study, the active sensing diagnostic system using PZT based smart rebar network shows a promising way to provide concrete crack damage information through the "talk" among sensors.

  14. Influence of tilt training on activation of the autonomic nervous system in patients with vasovagal syncope.

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Halawa, Bogumił; Mazurek, Walentyna

    2006-04-01

    Tilt training is a new treatment for vasovagal syncope. Its therapeutic efficacy is thought to be the result of the desensitization of cardiopulmonary receptors, but it could be the influence of the tilt training on the activation of the autonomic nervous system as well. The study group consisted of 24 vasovagal patients (17 women and 7 men) aged 32.5 +/- 11.8 years. The diagnostic head-up tilt test was performed according to the Italian protocol with nitroglycerin if necessary. The monitoring head-up tilt test was performed according to the Westminster protocol without provocation, after 1 to 3 months of tilt training. Holter ECG recordings for HRV parameters (time and frequency domain) were obtained from selected 2-min intervals before, during and after the diagnostic and monitoring tilt test. The diagnostic test was positive in the passive phase in 6 and after provocation in 18 patients. During the training period no syncope occurred. Analysing the HRV parameters we demonstrated the following findings: I. mRR decreases immediately after assumption of a vertical position in both tests (diagnostic and monitoring) but in the diagnostic test its further decrease occurs earlier than in the monitoring test; 2. the absolute power of the HF component is greater in the early phase of tilt after tilt training than in the corresponding period in the diagnostic test. After a longer period of tilt training the activation of the sympathetic nervous system in response to the erect position is diminished.

  15. Plasma endotoxin activity in kangaroos with oral necrobacillosis (lumpy jaw disease) using an automated handheld testing system

    PubMed Central

    SOTOHIRA, Yukari; SUZUKI, Kazuyuki; SASAKI, Haruka; SANO, Tadashi; TSUCHIYA, Masakazu; SUZUKI, Yohko; SHIMAMORI, Toshio; TSUKANO, Kenji; SATO, Ayano; YOKOTA, Hiroshi; ASAKAWA, Mitsuhiko

    2016-01-01

    The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTSTM) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTSTM was not significantly different from that of the traditional LAL-based assay. The data obtained using PTSTM correlated with those using KT (r2=0.963, P<0.001). These findings indicated that the PTSTM is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods. PMID:26902804

  16. Plasma endotoxin activity in kangaroos with oral necrobacillosis (lumpy jaw disease) using an automated handheld testing system.

    PubMed

    Sotohira, Yukari; Suzuki, Kazuyuki; Sasaki, Haruka; Sano, Tadashi; Tsuchiya, Masakazu; Suzuki, Yohko; Shimamori, Toshio; Tsukano, Kenji; Sato, Ayano; Yokota, Hiroshi; Asakawa, Mitsuhiko

    2016-07-01

    The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTS(TM)) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTS(TM) was not significantly different from that of the traditional LAL-based assay. The data obtained using PTS(TM) correlated with those using KT (r(2)=0.963, P<0.001). These findings indicated that the PTS(TM) is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods.

  17. Direct measurement of catalase activity in living cells and tissue biopsies.

    PubMed

    Scaglione, Christine N; Xu, Qijin; Ramanujan, V Krishnan

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies - can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Direct Measurement of Catalase Activity in Living Cells and Tissue Biopsies

    PubMed Central

    Scaglione, Christine N; Xu, Qijin; Ramanujan, V. Krishnan

    2016-01-01

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharamacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. PMID:26772884

  19. A Diagnostic System for Studying Energy Partitioning and Assessing the Response of the Ionosphere during HAARP Modification Experiments

    NASA Technical Reports Server (NTRS)

    Djuth, Frank T.; Elder, John H.; Williams, Kenneth L.

    1996-01-01

    This research program focused on the construction of several key radio wave diagnostics in support of the HF Active Auroral Ionospheric Research Program (HAARP). Project activities led to the design, development, and fabrication of a variety of hardware units and to the development of several menu-driven software packages for data acquisition and analysis. The principal instrumentation includes an HF (28 MHz) radar system, a VHF (50 MHz) radar system, and a high-speed radar processor consisting of three separable processing units. The processor system supports the HF and VHF radars and is capable of acquiring very detailed data with large incoherent scatter radars. In addition, a tunable HF receiver system having high dynamic range was developed primarily for measurements of stimulated electromagnetic emissions (SEE). A separate processor unit was constructed for the SEE receiver. Finally, a large amount of support instrumentation was developed to accommodate complex field experiments. Overall, the HAARP diagnostics are powerful tools for studying diverse ionospheric modification phenomena. They are also flexible enough to support a host of other missions beyond the scope of HAARP. Many new research programs have been initiated by applying the HAARP diagnostics to studies of natural atmospheric processes.

  20. The influence of a tilt training programme on the renin-angiotensin-aldosterone system activity in patients with vasovagal syncope.

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Krzemińska, Sylwia; Mazurek, Walentyna

    2009-08-01

    We assessed the influence of short-term and long-term tilt training on the activity of the renin-angiotensin-aldosterone system (RAAS) in vasovagal patients. Thirty-nine patients (28 F, 11 M) aged 39.7 +/- 11.2 years with a history of vasovagal syncope and a positive head-up tilt test (HUT) were studied. Blood samples for plasma renin activity (PRA) and aldosterone (ALDO) concentration were drawn at the baseline, immediately after HUT and 10 min after HUT, during the diagnostic, the negative short-term (2-5 days) follow-up HUT and long-term (1-3 months) follow-up HUT. Tilt training was started after diagnostic HUT. In diagnostic HUT, PRA increased significantly immediately after HUT comparing to the baseline, during recovery the values did not change. ALDO concentration increased after HUT comparing to baseline and further increased during recovery. After short-term tilt training, PRA and ALDO concentrations did not significantly change compared to their corresponding values in diagnostic HUT. After long-term tilt training, PRA did not significantly change compared to the values in the diagnostic and short-term follow-up HUT. ALDO concentration also did not change significantly at the baseline and immediately after HUT, and 10 min after HUT ALDO concentration was significantly lower than after diagnostic HUT. Tilt training changes the response of RAAS to the prolonged orthostasis in vasovagal patients. The coupling between PRA and ALDO after diagnostic HUT has been found to be altered and the physiological relationship was restored after long-term tilt training. The beneficial effect of tilt training depends partially on changed RAAS activation.

  1. Direct measurement of catalase activity in living cells and tissue biopsies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan, E-mail: Ramanujanv@csmc.edu

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Usingmore » catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear demonstration of the applicability in cancer cells and aging animal tissues.« less

  2. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    PubMed

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  3. Propulsion Controls and Diagnostics Research in Support of NASA Aeronautics and Exploration Mission Programs

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2011-01-01

    The Controls and Dynamics Branch (CDB) at National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research and Exploration Systems Missions. This paper provides a brief overview of the various CDB tasks in support of the NASA programs. The programmatic structure of the CDB activities is described along with a brief overview of each of the CDB tasks including research objectives, technical challenges, and recent accomplishments. These tasks include active control of propulsion system components, intelligent propulsion diagnostics and control for reliable fault identification and accommodation, distributed engine control, and investigations into unsteady propulsion systems.

  4. Autonomous diagnostics and prognostics of signal and data distribution systems

    NASA Astrophysics Data System (ADS)

    Blemel, Kenneth G.

    2001-07-01

    Wiring is the nervous system of any complex system and is attached to or services nearly every subsystem. Damage to optical wiring systems can cause serious interruptions in communication, command and control systems. Electrical wiring faults and failures due to opens, shorts, and arcing probably result in adverse effects to the systems serviced by the wiring. Abnormalities in a system usually can be detected by monitoring some wiring parameter such as vibration, data activity or power consumption. This paper introduces the mapping of wiring to critical functions during system engineering to automatically define the Failure Modes Effects and Criticality Analysis. This mapping can be used to define the sensory processes needed to perform diagnostics during system engineering. This paper also explains the use of Operational Modes and Criticality Effects Analysis in the development of Sentient Wiring Systems as a means for diagnostic, prognostics and health management of wiring in aerospace and transportation systems.

  5. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods.

    PubMed

    Cupek, Rafal; Ziębiński, Adam

    2016-01-01

    Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. This paper focus on a computer aided diagnostic system that was developed within joint Polish-Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner's experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner's experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an assessment of synovitis severity.

  6. Gear noise, vibration, and diagnostic studies at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Zakrajsek, James J.; Oswald, Fred B.; Townsend, Dennis P.; Coy, John J.

    1990-01-01

    The NASA Lewis Research Center and the U.S. Army Aviation Systems Command are involved in a joint research program to advance the technology of rotorcraft transmissions. This program consists of analytical as well as experimental efforts to achieve the overall goals of reducing weight, noise, and vibration, while increasing life and reliability. Recent analytical activities are highlighted in the areas of gear noise, vibration, and diagnostics performed in-house and through NASA and U.S. Army sponsored grants and contracts. These activities include studies of gear tooth profiles to reduce transmission error and vibration as well as gear housing and rotordynamic modeling to reduce structural vibration transmission and noise radiation, and basic research into current gear failure diagnostic methodologies. Results of these activities are presented along with an overview of near term research plans in the gear noise, vibration, and diagnostics area.

  7. On-board fault diagnostics for fly-by-light flight control systems using neural network flight processors

    NASA Astrophysics Data System (ADS)

    Urnes, James M., Sr.; Cushing, John; Bond, William E.; Nunes, Steve

    1996-10-01

    Fly-by-Light control systems offer higher performance for fighter and transport aircraft, with efficient fiber optic data transmission, electric control surface actuation, and multi-channel high capacity centralized processing combining to provide maximum aircraft flight control system handling qualities and safety. The key to efficient support for these vehicles is timely and accurate fault diagnostics of all control system components. These diagnostic tests are best conducted during flight when all facts relating to the failure are present. The resulting data can be used by the ground crew for efficient repair and turnaround of the aircraft, saving time and money in support costs. These difficult to diagnose (Cannot Duplicate) fault indications average 40 - 50% of maintenance activities on today's fighter and transport aircraft, adding significantly to fleet support cost. Fiber optic data transmission can support a wealth of data for fault monitoring; the most efficient method of fault diagnostics is accurate modeling of the component response under normal and failed conditions for use in comparison with the actual component flight data. Neural Network hardware processors offer an efficient and cost-effective method to install fault diagnostics in flight systems, permitting on-board diagnostic modeling of very complex subsystems. Task 2C of the ARPA FLASH program is a design demonstration of this diagnostics approach, using the very high speed computation of the Adaptive Solutions Neural Network processor to monitor an advanced Electrohydrostatic control surface actuator linked through a AS-1773A fiber optic bus. This paper describes the design approach and projected performance of this on-line diagnostics system.

  8. Systemic mast cell activation disease: the role of molecular genetic alterations in pathogenesis, heritability and diagnostics

    PubMed Central

    Haenisch, Britta; Nöthen, Markus M; Molderings, Gerhard J

    2012-01-01

    Despite increasing understanding of its pathophysiology, the aetiology of systemic mast cell activation disease (MCAD) remains largely unknown. Research has shown that somatic mutations in kinases are necessary for the establishment of a clonal mast cell population, in particular mutations in the tyrosine kinase Kit and in enzymes and receptors with crucial involvement in the regulation of mast cell activity. However, other, as yet undetermined, abnormalities are necessary for the manifestation of clinical disease. The present article reviews molecular genetic research into the identification of disease-associated genes and their mutational alterations. The authors also present novel data on familial systemic MCAD and review the associated literature. Finally, the importance of understanding the molecular basis of inherited mutations in terms of diagnostics and therapy is emphasized. PMID:22957768

  9. Emerging applications of nanoparticles for lung cancer diagnosis and therapy

    NASA Astrophysics Data System (ADS)

    Sukumar, Uday Kumar; Bhushan, Bharat; Dubey, Poornima; Matai, Ishita; Sachdev, Abhay; Packirisamy, Gopinath

    2013-07-01

    Lung cancer is by far the leading cause of cancer-related mortality worldwide, most of them being active tobacco smokers. Non small cell lung cancer accounts for around 85% to 90% of deaths, whereas the rest is contributed by small cell lung cancer. The extreme lethality of lung cancer arises due to lack of suitable diagnostic procedures for early detection of lung cancer and ineffective conventional therapeutic strategies. In course with desperate attempts to address these issues independently, a multifunctional nanotherapeutic or diagnostic system is being sought as a favorable solution. The manifestation of physiochemical properties of such nanoscale systems is tuned favorably to come up with a versatile cancer cell targeted diagnostic and therapeutic system. Apart from this, the aspect of being at nanoscale by itself confers the system with an advantage of passive accumulation at the site of tumor. This review provides a broad perspective of three major subclasses of such nanoscale therapeutic and diagnostic systems which include polymeric nanoparticles-based approaches, metal nanoparticles-based approaches, and bio-nanoparticles-based approaches. This review work also serves the purpose of gaining an insight into the pros and cons of each of these approaches with a prospective improvement in lung cancer therapeutics and diagnostics.

  10. [Theoretical grounds of a structural and functional model for quality assurance of radiation diagnostics under conditions of development of the modern health care system in Ukraine].

    PubMed

    Korop, Oleg A; Lenskykh, Sergiy V

    2018-01-01

    Introduction: Modern changes in the health care system of Ukraine are focused on financial support in providing medical and diagnostic care to the population and are based on deep and consistent structural and functional transformations. They are aimed at providing adequate quality care, which is the main target function and a principal criterion for operation of health care system. The urgency of this problem is increasing in the context of reforming the health care system and global changes in the governmental financial guarantees for the provision of medical services to the population. The aim of the work is to provide theoretical grounds for a structural and functional model of quality assurance of radiation diagnostics at all levels of medical care given to the population under the current health care reform in Ukraine. Materials and methods: The object of the study is organizing the operation of the radiation diagnostic service; the information is based on the actual data on the characteristics of radiation diagnosis at different levels of medical care provision. Methods of systematic approach, system analysis and structural and functional analysis of the operating system of radiation diagnostics are used. Review: The basis of the quality assurance model is the cyclical process, which includes the stages of the problem identifition, planning of its solution, organization of the system for implementation of decisions, monitoring the quality management process of the radiation diagnostics, and factors influencing the quality of the radiation diagnostics service. These factors include the quality of the structure, process, results, organization of management and control of current processes and the results of radiation diagnostics management. Conclusions: The advantages of the proposed model for ensuring the quality of the radiation diagnostics service are its systemacy and complexity, elimination of identified defects and deficiencies, and achievement of profitability through modern redistribution and use of existing resources of the health care system. The results of adequate service quality management activities in radiation diagnostics are the improvement of organizational and economic principles along with legislative regulation, the implementation of a modern system of radiation diagnostics in the state health care at the national and regional levels, the increase of the accessibility, quality and efficiency of the radiation diagnostics service.

  11. Development of an Adaptable Display and Diagnostic System for the Evaluation of Tropical Cyclone Forecasts

    NASA Astrophysics Data System (ADS)

    Kucera, P. A.; Burek, T.; Halley-Gotway, J.

    2015-12-01

    NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.

  12. Economic evaluations of point of care testing strategies for active tuberculosis.

    PubMed

    Zwerling, Alice; Dowdy, David

    2013-06-01

    Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.

  13. Diagnostic Machine Learning Models for Acute Abdominal Pain: Towards an e-Learning Tool for Medical Students.

    PubMed

    Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin

    2017-01-01

    Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.

  14. Are health care provider organizations ready to tackle diagnostic error? A survey of Leapfrog-participating hospitals.

    PubMed

    Newman-Toker, David E; Austin, J Matthew; Derk, Jordan; Danforth, Melissa; Graber, Mark L

    2017-06-27

    A 2015 National Academy of Medicine report on improving diagnosis in health care made recommendations for direct action by hospitals and health systems. Little is known about how health care provider organizations are addressing diagnostic safety/quality. This study is an anonymous online survey of safety professionals from US hospitals and health systems in July-August 2016. The survey was sent to those attending a Leapfrog Group webinar on misdiagnosis (n=188). The instrument was focused on knowledge, attitudes, and capability to address diagnostic errors at the institutional level. Overall, 61 (32%) responded, including community hospitals (42%), integrated health networks (25%), and academic centers (21%). Awareness was high, but commitment and capability were low (31% of leaders understand the problem; 28% have sufficient safety resources; and 25% have made diagnosis a top institutional safety priority). Ongoing efforts to improve diagnostic safety were sparse and mostly included root cause analysis and peer review feedback around diagnostic errors. The top three barriers to addressing diagnostic error were lack of awareness of the problem, lack of measures of diagnostic accuracy and error, and lack of feedback on diagnostic performance. The top two tools viewed as critically important for locally tackling the problem were routine feedback on diagnostic performance and culture change to emphasize diagnostic safety. Although hospitals and health systems appear to be aware of diagnostic errors as a major safety imperative, most organizations (even those that appear to be making a strong commitment to patient safety) are not yet doing much to improve diagnosis. Going forward, efforts to activate health care organizations will be essential to improving diagnostic safety.

  15. Experienced and less-experienced nurses' diagnostic reasoning: implications for fostering students' critical thinking.

    PubMed

    Ferrario, Catherine G

    2003-01-01

    To compare the use of mental representations (heuristics) in diagnostic reasoning of expert (> or = 5 years' experience) and novice (< 5 years' experience) emergency nurses. Clinical simulations were completed by a nationwide randomly selected sample of 173 experienced and 46 less-experienced emergency nurses (N = 219). Experienced nurses used the heuristic, Judging by Causal Systems (diagnostic inferences deduced from systems of causal factors) significantly more did than less-experienced nurses. Standardized nursing diagnoses may cut short the time needed to develop representational thinking and spare cognitive reserves for reasoning needed for complex patients. Faculty need to promote student's cognitive development through strategies that promote active, reflective, and integrative learning.

  16. Extreme ultraviolet diagnostic upgrades for kink mode control on the HBT-EP tokamak

    NASA Astrophysics Data System (ADS)

    Levesque, J. P.; Brooks, J. W.; Desanto, S.; Mauel, M. E.; Navratil, G. A.; Page, J. W.; Hansen, C. J.; Delgado-Aparicio, L.

    2016-10-01

    Optical diagnostics can provide non-invasive measurements of tokamak equilibria and the internal characteristics of MHD mode activity. We present research plans and ongoing progress on upgrading extreme ultraviolet (EUV) diagnostics in the HBT-EP tokamak. Four sets of 16 poloidal views will allow tomographic reconstruction of plasma emissivity and internal kink mode structure. Emission characteristics of naturally-occurring m/n = 2/1, 3/2, and 3/1 tearing and kink modes will be compared with expectations from a synthetic diagnostic. Coupling between internal and external modes leading up to disruptions is studied. The internal plasma response to external magnetic perturbations is investigated, and compared with magnetic response measurements. Correlation between internal emissivity and external magnetic measurements provides a global picture of long-wavelength MHD instabilities. Measurements are input to HBT-EP's GPU-based feedback system, allowing active feedback for kink modes using only optical sensors and both magnetic and edge current actuators. A separate two-color, 16-chord tangential system will be installed next year to allow reconstruction of temperature profiles and their fluctuations versus time. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  17. Detection of Rare Antimicrobial Resistance Profiles by Active and Passive Surveillance Approaches

    PubMed Central

    Mather, Alison E.; Reeve, Richard; Mellor, Dominic J.; Matthews, Louise; Reid-Smith, Richard J.; Haydon, Daniel T.; Reid, Stuart W. J.

    2016-01-01

    Antimicrobial resistance (AMR) surveillance systems are generally not specifically designed to detect emerging resistances and usually focus primarily on resistance to individual drugs. Evaluating the diversity of resistance, using ecological metrics, allows the assessment of sampling protocols with regard to the detection of rare phenotypes, comprising combinations of resistances. Surveillance data of phenotypic AMR of Canadian poultry Salmonella Heidelberg and swine Salmonella Typhimurium var. 5- were used to contrast active (representative isolates derived from healthy animals) and passive (diagnostic isolates) surveillance and assess their suitability for detecting emerging resistance patterns. Although in both datasets the prevalences of resistance to individual antimicrobials were not significantly different between the two surveillance systems, analysis of the diversity of entire resistance phenotypes demonstrated that passive surveillance of diagnostic isolates detected more unique phenotypes. Whilst the most appropriate surveillance method will depend on the relevant objectives, under the conditions of this study, passive surveillance of diagnostic isolates was more effective for the detection of rare and therefore potentially emerging resistance phenotypes. PMID:27391966

  18. IT-based diagnostic instrumentation systems for personalized healthcare services.

    PubMed

    Chun, Honggu; Kang, Jaemin; Kim, Ki-Jung; Park, Kwang Suk; Kim, Hee Chan

    2005-01-01

    This paper describes recent research and development activities on the diagnostic instruments for personalized healthcare services in Seoul National University. Utilizing the state-of-the-art information technologies (IT), various diagnostic medical instruments have been integrated into a personal wearable device and a home telehealthcare system. We developed a wrist-worn integrated health monitoring device (WIHMD) which performs the measurements of non-invasive blood pressure (NIBP), pulse oximetry (SpO2), electrocardiogram (ECG), respiration rate, heart rate, and body surface temperature and the detection of falls to determine the onset of emergency situation. The WIHMD also analyzes the acquired bio-signals and transmits the resultant data to a healthcare service center through a commercial cellular phone. Two different kinds of IT-based blood glucometer have been developed using a cellular phone and PDA(personal digital assistant) as a main unit. A blood glucometer was also integrated within a wrist pressure measurement module which is interfaced with a cellular phone via Telecommunications Technology Association (TTA) standard in order to provide users with easiness in measuring and handling two important health parameters. Non-intrusive bio-signal measurement systems were developed for the ease of home use. One can measure his ECG on a bed while he is sleeping; measure his ECG, body temperature, bodyfat ratio and weight on a toilet seat; measure his ECG on a chair; and estimate the degree of activity by motion analysis using a camera. Another integrated diagnostic system for home telehealthcare services has been developed to include a 12 channels ECG, a pressure meter for NIBP, a blood glucometer, a bodyfat meter and a spirometer. It is an expert system to analyze the measured health data and based on the diagnostic result, the system provides an appropriate medical consultation. The measured data can be either stored on the system or transmitted to the central server through the internet. We have installed the developed systems on a model house for the performance evaluation and confirmed the possibility of the system as an effective tool for the personalized healthcare services.

  19. Developing system for delivery of optical radiation in medicobiological researches

    NASA Astrophysics Data System (ADS)

    Loschenov, Victor B.; Taraz, Majid

    2004-06-01

    Methods of optical diagnostics and methods of photodynamic therapy are actively used in medico-biological researches. The system for delivery of optical radiation is one of the key methods in these researches. Usually these systems use flexible optical fibers with diameters from 200 to 1000 micron. Two types of systems for delivery are subdivided, first for diagnostic researches, second for therapeutic procedures. Existing diagnostic catheters, which have most widely applied in medicine, have bifurcated with diameter of the tip equal 1.8 mm. These devices, which are called fiber-optical catheters, satisfy the majority endoscopes researches. However, till now the problem of optical-diagnostics inside tissue is not soled. Especially it is important at diagnostics of a mammary gland, livers, thyroid glands tumor, tumor of a brain and some other studies connected with punctures. In these cases, it is necessary that diameter of fiber-optical catheters be less than one millimeter. This work is devoted to the development of these catheters. Also in clinical procedures such as photodynamic therapy (PDT) and interstitial laser photocoagulation (ILP), cylindrical light diffusing tips are rapidly becoming a popular device for the administration of the desired light dose for the illumination of hollow organs, such as bronchus, trachea and oesophagus. This work is devoted to the development of these catheters.

  20. [THE ROLE OF SYSTEM QUORUM SENSING UNDER CHRONIC UROGENITAL CHLAMYDIA INFECTION].

    PubMed

    2015-10-01

    It is established that system quorum sensing (QS) assure social behavior of bacteria in regulation of genes of virulence and generalization of inflectional inflammatory process under chronic urogenital chlamydia infection. The techniques of gas chromatography and mass-spectrometry were applied to detect molecular markers of generalization of infectious process under urogenital chlamydiasis--activators of QS microbes (lactones, quinolones, furan ethers). The developed diagnostic gas chromatography and mass-spectrometry criteria of indexation of molecular markers under chronic urogenital chlamydia infection have high level of diagnostic sensitivity, specificity and prognostic value of positive and negative result. The application of techniques of gas chromatography and mass-spectrometry permits enhancing effectiveness of diagnostic of chronic inflectional inflammatory diseases of urogenital system of chlamydia etiology with identification of prognostic criteria of generalization of infectious process and subsequent prescription of timely and appropriate therapy

  1. A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility (invited)

    NASA Astrophysics Data System (ADS)

    Yeamans, C. B.; Gharibyan, N.

    2016-11-01

    At the National Ignition Facility, the diagnostic instrument manipulator-based neutron activation spectrometer is used as a diagnostic of implosion performance for inertial confinement fusion experiments. Additionally, it serves as a platform for independent neutronic experiments and may be connected to fast recording systems for neutron effect tests on active electronics. As an implosion diagnostic, the neutron activation spectrometers are used to quantify fluence of primary DT neutrons, downscattered neutrons, and neutrons above the primary DT neutron energy created by reactions of upscattered D and T in flight. At a primary neutron yield of 1015 and a downscattered fraction of neutrons in the 10-12 MeV energy range of 0.04, the downscattered neutron fraction can be measured to a relative uncertainty of 8%. Significant asymmetries in downscattered neutrons have been observed. Spectrometers have been designed and fielded to measure the tritium-tritium and deuterium-tritium neutron outputs simultaneously in experiments using DT/TT fusion ratio as a direct measure of mix of ablator into the gas.

  2. A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility (invited).

    PubMed

    Yeamans, C B; Gharibyan, N

    2016-11-01

    At the National Ignition Facility, the diagnostic instrument manipulator-based neutron activation spectrometer is used as a diagnostic of implosion performance for inertial confinement fusion experiments. Additionally, it serves as a platform for independent neutronic experiments and may be connected to fast recording systems for neutron effect tests on active electronics. As an implosion diagnostic, the neutron activation spectrometers are used to quantify fluence of primary DT neutrons, downscattered neutrons, and neutrons above the primary DT neutron energy created by reactions of upscattered D and T in flight. At a primary neutron yield of 10 15 and a downscattered fraction of neutrons in the 10-12 MeV energy range of 0.04, the downscattered neutron fraction can be measured to a relative uncertainty of 8%. Significant asymmetries in downscattered neutrons have been observed. Spectrometers have been designed and fielded to measure the tritium-tritium and deuterium-tritium neutron outputs simultaneously in experiments using DT/TT fusion ratio as a direct measure of mix of ablator into the gas.

  3. Propulsion Controls and Diagnostics Research at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2007-01-01

    With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. Also the propulsion systems required to enable the National Aeronautics and Space Administration (NASA) Vision for Space Exploration in an affordable manner will need to have high reliability, safety and autonomous operation capability. The Controls and Dynamics Branch (CDB) at NASA Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of Intelligent Propulsion Systems. This paper describes the current activities of the CDB under the NASA Aeronautics Research and Exploration Systems Missions. The programmatic structure of the CDB activities is described along with a brief overview of each of the CDB tasks including research objectives, technical challenges, and recent accomplishments. These tasks include active control of propulsion system components, intelligent propulsion diagnostics and control for reliable fault identification and accommodation, distributed engine control, and investigations into unsteady propulsion systems.

  4. Diagnosing students' misconceptions in algebra: results from an experimental pilot study.

    PubMed

    Russell, Michael; O'Dwyer, Laura M; Miranda, Helena

    2009-05-01

    Computer-based diagnostic assessment systems hold potential to help teachers identify sources of poor performance and to connect teachers and students to learning activities designed to help advance students' conceptual understandings. The present article presents findings from a study that examined how students' performance in algebra and their overcoming of common algebraic misconceptions were affected by the use of a diagnostic assessment system that focused on important algebra concepts. This study used a four-group randomized cluster trial design in which teachers were assigned randomly to one of four groups: a "business as usual" control group, a partial intervention group that was provided with access to diagnostic tests results, a partial intervention group that was provided with access to the learning activities, and a full intervention group that was given access to the test results and learning activities. Data were collected from 905 students (6th-12th grade) nested within 44 teachers. We used hierarchical linear modeling techniques to compare the effects of full, partial, and no (control) intervention on students' algebraic ability and misconceptions. The analyses indicate that full intervention had a net positive effect on ability and misconception measures.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoaf, S.; APS Engineering Support Division

    A real-time image analysis system was developed for beam imaging diagnostics. An Apple Power Mac G5 with an Active Silicon LFG frame grabber was used to capture video images that were processed and analyzed. Software routines were created to utilize vector-processing hardware to reduce the time to process images as compared to conventional methods. These improvements allow for more advanced image processing diagnostics to be performed in real time.

  6. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    PubMed

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Diagnostics of the power oil-filled transformer equipment of thermal power plants

    NASA Astrophysics Data System (ADS)

    Eltyshev, D. K.; Khoroshev, N. I.

    2016-08-01

    Problems concerning improvement of the diagnostics efficiency of the electrical facilities and functioning of the generation and distribution systems through the examples of the power oil-filled transformers, as the responsible elements referring to the electrical part of thermal power plants (TPP), were considered. Research activity is based on the fuzzy logic system allowing working both with statistical and expert information presented in the form of knowledge accumulated during operation of the power oil-filled transformer facilities. The diagnostic algorithm for various types of transformers, with the use of the intellectual estimation model of its thermal state on the basis of the key diagnostic parameters and fuzzy inference hierarchy, was developed. Criteria for taking measures allowing preventing emergencies in the electric power systems were developed. The fuzzy hierarchical model for the state assessment of the power oil-filled transformers of 110 kV, possessing high degree of credibility and setting quite strict requirements to the limits of variables of the equipment diagnostic parameters, was developed. The most frequent defects of the transformer standard elements, related with the disturbance of the isolation properties and instrumentation operation, were revealed after model testing on the real object. Presented results may be used both for the express diagnostics of the transformers state without disconnection from the power line and for more detailed analysis of the defects causes on the basis of the advanced list of the diagnostic parameters; information on those parameters may be received only after complete or partial disconnection.

  8. Development of the STPX Spheromak System

    NASA Astrophysics Data System (ADS)

    Williams, R. L.; Clark, J.; Weatherford, C. A.

    2015-11-01

    The progress made in starting up the STPX Spheromak system, which is now installed at the Florida A&M University, is reviewed. Experimental, computational and theoretical activities are underway. The control system for firing the magnetized coaxial plasma gun and for collecting data from the diagnostic probes, based on LabView, is being tested and adapted. Preliminary results of testing the installed magnetic field probes, Langmuir triple probes, cylindrical ion probes, and optical diagnostics will be discussed. Progress in modeling this spheromak using simulation codes, such as NIMROD, will be discussed. Progress in investigating the use of algebraic topology to describe this spheromak will be reported.

  9. Expert diagnostics system as a part of analysis software for power mission operations

    NASA Technical Reports Server (NTRS)

    Harris, Jennifer A.; Bahrami, Khosrow A.

    1993-01-01

    The operation of interplanetary spacecraft at JPL has become an increasingly complex activity. This complexity is due to advanced spacecraft designs and ambitious mission objectives which lead to operations requirements that are more demanding than those of any previous mission. For this reason, several productivity enhancement measures are underway at JPL within mission operations, particularly in the spacecraft analysis area. These measures aimed at spacecraft analysis include: the development of a multi-mission, multi-subsystem operations environment; the introduction of automated tools into this environment; and the development of an expert diagnostics system. This paper discusses an effort to integrate the above mentioned productivity enhancement measures. A prototype was developed that integrates an expert diagnostics system into a multi-mission, multi-subsystem operations environment using the Galileo Power / Pyro Subsystem as a testbed. This prototype will be discussed in addition to background information associated with it.

  10. Systemic lupus erythematosus diagnostics in the ‘omics’ era

    PubMed Central

    Arriens, Cristina; Mohan, Chandra

    2014-01-01

    Systemic lupus erythematosus is a complex autoimmune disease affecting multiple organ systems. Currently, diagnosis relies upon meeting at least four out of eleven criteria outlined by the ACR. The scientific community actively pursues discovery of novel diagnostics in the hope of better identifying susceptible individuals in early stages of disease. Comprehensive studies have been conducted at multiple biological levels including: DNA (or genomics), mRNA (or transcriptomics), protein (or proteomics) and metabolites (or metabolomics). The ‘omics’ platforms allow us to re-examine systemic lupus erythematosus at a greater degree of molecular resolution. More importantly, one is hopeful that these ‘omics’ platforms may yield newer biomarkers for systemic lupus erythematosus that can help clinicians track the disease course with greater sensitivity and specificity. PMID:24860621

  11. Current Research Activities in Drive System Technology in Support of the NASA Rotorcraft Program

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Zakrajsek, James J.

    2006-01-01

    Drive system technology is a key area for improving rotorcraft performance, noise/vibration reduction, and reducing operational and manufacturing costs. An overview of current research areas that support the NASA Rotorcraft Program will be provided. Work in drive system technology is mainly focused within three research areas: advanced components, thermal behavior/emergency lubrication system operation, and diagnostics/prognostics (also known as Health and Usage Monitoring Systems (HUMS)). Current research activities in each of these activities will be presented. Also, an overview of the conceptual drive system requirements and possible arrangements for the Heavy Lift Rotorcraft program will be reviewed.

  12. Built-in active sensing diagnostic system for civil infrastructure systems

    NASA Astrophysics Data System (ADS)

    Wu, Fan; Chang, Fu-Kuo

    2001-07-01

    A reliable, robust monitoring system can improve the maintenance of and provide safety protection for civil structures and therefore prolong their service lives. A built-in, active sensing diagnostic technique for civil structures has been under investigation. In this technique, piezoelectric materials are used as sensors/actuators to receive and generate signals. The transducers are embedded in reinforced concrete (RC) beams and are designed to detect damage, particularly debonding damage between the reinforcing bars and concrete. This paper presents preliminary results from a feasibility study of the technology. Laboratory experiments performed on RC beams, with piezo-electric sensors and actuators mounted on reinforced steel bars, have clearly demonstrated that the proposed technique could detect debonding damage. Analytical work, using a special purpose finite-element software, PZFlex, was also conducted to interpret the relationship between the measured data and actual debonding damage. Effectiveness of the proposed technique for detecting debonding damage in civil structures has been demonstrated.

  13. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    PubMed

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  14. Conversion-Integration of MSFC Nonlinear Signal Diagnostic Analysis Algorithms for Realtime Execution of MSFC's MPP Prototype System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1996-01-01

    NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.

  15. [Establishment of the rapid, hypersensitive testing systems for sepsis/SIRS].

    PubMed

    Kitajima, Isao; Niimi, Hideki

    2012-01-01

    We developed a new infectious disease diagnostic system in order to raise the lifesaving rate in systemic inflammatory reactive syndrome, SIRS. Using eukaryote-derived thermostable DNA polymerase, the sensitive and reliable detection of bacteria becomes feasible for large fields, thereby making the development of a wide range of powerful applications possible. Further, we have established a novel measurement system for NF-kappaB activity using fluorescence correlation spectroscopy(FCS) because the elevation of NF-kappaB activity reflects acute inflammation. NF-kappaB activity measurement in patients with SIRS may provide a useful inflammatory marker.

  16. Infield masticatory muscle activity in subjects with pain-related temporomandibular disorders diagnoses.

    PubMed

    Khawaja, S N; McCall, W; Dunford, R; Nickel, J C; Iwasaki, L R; Crow, H C; Gonzalez, Y

    2015-04-01

    Pain-related temporomandibular disorders (TMDs) are the most prevalent conditions among TMDs. There is contrasting evidence available for association of pain-related TMD and masticatory muscle activity (MMA). The present investigation assesses the associations between MMA levels of masseter and temporalis muscles during awake and sleep among pain-related TMD diagnostic groups. The department of Oral Diagnostic Sciences, University at Buffalo. Twenty females and six males participated in this study. Using the diagnostic criteria for temporomandibular disorders (DC-TMDs), participants were diagnostically categorized. Subjects used a custom monitoring system, which recorded infield muscle activities. A factorial model tested for association between independent variable (muscle, time period, MMA level, and diagnostic group) effects and the logarithm of MMA. Greenhouse-Geisser test was used to determine any statistically significant associations (p≤0.003). No statistically significant association was found between four-way, three-way, and two-way analyses. However, among the main effects, range of magnitudes was the only variable to be statistically significant. Although the data suggest a trend of increased masseter MMA in the pain-related TMD diagnoses group both during awake and sleep time periods, such observation is not maintained for the temporalis muscle. In addition, temporalis MMA was found to be higher in the pain-related TMD diagnoses group only at extreme activity levels (<25 and ≥80% ranges). This data support the association between masticatory muscle hyperactivity and painful TMD conditions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Reviews of Selected System and Software Tools for Strategic Defense Applications

    DTIC Science & Technology

    1990-02-01

    Interleaf and FrameMaker . IStatic Diagnostics Basic testing includes validating flows, detecting orphan activity, and checking completeness of activities...Publisher, Aldus PageMaker, Unix pic, Apple .pict metafile, Interleaf, Framemaker , or Postscript format. There are no forms for standard documents such as 3

  18. Using targeted active-learning exercises and diagnostic question clusters to improve students' understanding of carbon cycling in ecosystems.

    PubMed

    Maskiewicz, April Cordero; Griscom, Heather Peckham; Welch, Nicole Turrill

    2012-01-01

    In this study, we used targeted active-learning activities to help students improve their ways of reasoning about carbon flow in ecosystems. The results of a validated ecology conceptual inventory (diagnostic question clusters [DQCs]) provided us with information about students' understanding of and reasoning about transformation of inorganic and organic carbon-containing compounds in biological systems. These results helped us identify specific active-learning exercises that would be responsive to students' existing knowledge. The effects of the active-learning interventions were then examined through analysis of students' pre- and postinstruction responses on the DQCs. The biology and non-biology majors participating in this study attended a range of institutions and the instructors varied in their use of active learning; one lecture-only comparison class was included. Changes in pre- to postinstruction scores on the DQCs showed that an instructor's teaching method had a highly significant effect on student reasoning following course instruction, especially for questions pertaining to cellular-level, carbon-transforming processes. We conclude that using targeted in-class activities had a beneficial effect on student learning regardless of major or class size, and argue that using diagnostic questions to identify effective learning activities is a valuable strategy for promoting learning, as gains from lecture-only classes were minimal.

  19. Using Targeted Active-Learning Exercises and Diagnostic Question Clusters to Improve Students' Understanding of Carbon Cycling in Ecosystems

    PubMed Central

    Maskiewicz, April Cordero; Griscom, Heather Peckham; Welch, Nicole Turrill

    2012-01-01

    In this study, we used targeted active-learning activities to help students improve their ways of reasoning about carbon flow in ecosystems. The results of a validated ecology conceptual inventory (diagnostic question clusters [DQCs]) provided us with information about students' understanding of and reasoning about transformation of inorganic and organic carbon-containing compounds in biological systems. These results helped us identify specific active-learning exercises that would be responsive to students' existing knowledge. The effects of the active-learning interventions were then examined through analysis of students' pre- and postinstruction responses on the DQCs. The biology and non–biology majors participating in this study attended a range of institutions and the instructors varied in their use of active learning; one lecture-only comparison class was included. Changes in pre- to postinstruction scores on the DQCs showed that an instructor's teaching method had a highly significant effect on student reasoning following course instruction, especially for questions pertaining to cellular-level, carbon-transforming processes. We conclude that using targeted in-class activities had a beneficial effect on student learning regardless of major or class size, and argue that using diagnostic questions to identify effective learning activities is a valuable strategy for promoting learning, as gains from lecture-only classes were minimal. PMID:22383618

  20. Initial results from the NSTX Real-Time Velocity diagnostic

    NASA Astrophysics Data System (ADS)

    Podesta, M.; Bell, R. E.

    2011-10-01

    A new diagnostic for fast measurements of plasma rotation through active charge-exchange recombination spectroscopy (CHERS) was installed on NSTX. The diagnostic infers toroidal rotation from carbon ions undergoing charge-exchange with neutrals from a heating Neutral Beam (NB). Each of the 4 channels, distributed along the outer major radius, includes active views intercepting the NB and background views missing the beam. Estimated uncertainties in the measured velocity are <5% at the maximum sampling rate of 5000 Hz (or <1% at 1000 Hz), to be compared with <0.5% and 100 Hz of the main NSTX CHERS system. Signals are acquired on 2 CCD detectors, each controlled by a dedicated PC. Spectra are fitted in real-time through a C++ processing code and velocities are made available to the Plasma Control System for future implementation of feedback on velocity. Results from the initial operation during the 2011 run are discussed, emphasizing the fast dynamics of toroidal rotation, e . g . during L-H mode transition and breaking caused by instabilities and by externally-imposed magnetic perturbations. Work supported by USDOE Contract No. DE-AC02-09CH11466.

  1. ISHM-oriented adaptive fault diagnostics for avionics based on a distributed intelligent agent system

    NASA Astrophysics Data System (ADS)

    Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei

    2015-10-01

    In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.

  2. Photovoltaic test and demonstration project. [residential energy program

    NASA Technical Reports Server (NTRS)

    Forestieri, A. F.; Brandhorst, H. W., Jr.; Deyo, J. N.

    1976-01-01

    The considered project consists of three subprojects related to applications, device performance and diagnostics, and endurance testing. The objectives of the applications subproject include the determination of the operating characteristics for a variety of photovoltaic conversion systems. A system test facility is being constructed in this connection and a prototype residence experiment is to be conducted. Market demand for solar cells is to be stimulated by demonstrating suitability of solar cells for specific near-term applications. Activities conducted in connection with device performance studies and diagnostics are also discussed along with developments in the area of endurance testing.

  3. Dyspnoea, cyanosis and digital clubbing in a 28-year-old patient as a result of hepatopulmonary syndrome.

    PubMed

    Zieliński, Michał; Hartleb, Marek; Sitek, Piotr; Ziora, Dariusz

    2017-01-01

    This paper presents a case of a young patient with cyanosis and digital clubbing, until then an active, sporty person. He sought medical assistance due to the growing dyspnoea and the drop of effort tolerance. Initially the diagnostic process focused on the confirmation of the suspicion of pulmonary fibrosis or another interstitial lung disease as causes of the respiratory failure. Due to the atypical presentation of the symptoms, reaching the final diagnosis of digestive system disease with lung involvement required a more thorough multifaceted diagnostics of a number of systems and organs.

  4. Clinical study of quantitative diagnosis of early cervical cancer based on the classification of acetowhitening kinetics

    NASA Astrophysics Data System (ADS)

    Wu, Tao; Cheung, Tak-Hong; Yim, So-Fan; Qu, Jianan Y.

    2010-03-01

    A quantitative colposcopic imaging system for the diagnosis of early cervical cancer is evaluated in a clinical study. This imaging technology based on 3-D active stereo vision and motion tracking extracts diagnostic information from the kinetics of acetowhitening process measured from the cervix of human subjects in vivo. Acetowhitening kinetics measured from 137 cervical sites of 57 subjects are analyzed and classified using multivariate statistical algorithms. Cross-validation methods are used to evaluate the performance of the diagnostic algorithms. The results show that an algorithm for screening precancer produced 95% sensitivity (SE) and 96% specificity (SP) for discriminating normal and human papillomavirus (HPV)-infected tissues from cervical intraepithelial neoplasia (CIN) lesions. For a diagnostic algorithm, 91% SE and 90% SP are achieved for discriminating normal tissue, HPV infected tissue, and low-grade CIN lesions from high-grade CIN lesions. The results demonstrate that the quantitative colposcopic imaging system could provide objective screening and diagnostic information for early detection of cervical cancer.

  5. NASA Glenn Research in Controls and Diagnostics for Intelligent Aerospace Propulsion Systems

    NASA Technical Reports Server (NTRS)

    2005-01-01

    With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. Also the propulsion systems required to enable the NASA (National Aeronautics and Space Administration) Vision for Space Exploration in an affordable manner will need to have high reliability, safety and autonomous operation capability. The Controls and Dynamics Branch at NASA Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of Intelligent Propulsion Systems. The key enabling technologies for an Intelligent Propulsion System are the increased efficiencies of components through active control, advanced diagnostics and prognostics integrated with intelligent engine control to enhance operational reliability and component life, and distributed control with smart sensors and actuators in an adaptive fault tolerant architecture. This paper describes the current activities of the Controls and Dynamics Branch in the areas of active component control and propulsion system intelligent control, and presents some recent analytical and experimental results in these areas.

  6. Ultrasound and MRI of nerves for monitoring disease activity and treatment effects in chronic dysimmune neuropathies - Current concepts and future directions.

    PubMed

    Décard, Bernhard F; Pham, Mirko; Grimm, Alexander

    2018-01-01

    New imaging modalities like high-resolution-ultrasound (HRUS) and MR-Neurography (MRN) are increasingly used for the evaluation of the peripheral nervous system. The increasing knowledge on morphological changes observed in different neuropathies has led to a better understanding of underlying pathophysiological processes. The diagnosis of acquired chronic dysimmune neuropathies (CDN) like chronic inflammatory demyelinating polyneuropathy (CIDP), Lewis-Sumner Syndrome (LSS) or multifocal motor neuropathy (MMN) can be challenging. The current diagnostic criteria and outcome parameters are mainly based on clinical and electrophysiological parameters. Especially in CDN cases with atypical presentation or during early disease stages, the diagnostic accuracy is low and standardized protocols for the evaluation of disease activity and treatment response are lacking. The establishment of combined diagnostic criteria for CDN including imaging modalities could help to improve the diagnostic accuracy, allow a better differentiation of subtypes and facilitate the follow-up of disease course. The appropriate selection of eligible patients and sensitive monitoring of treatment response is mandatory future in treatment trials. In this article, we briefly summarize the clinical presentations and pathophysiological concepts of different CDN like CIDP, LSS and MMN. Furthermore, this review focuses on the diagnostic value of HRUS/MRN and its potential role for the monitoring of disease activity. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  7. Diagnostic medical physicists and their clinical activities.

    PubMed

    Cypel, Yasmin S; Sunshine, Jonathan H

    2004-02-01

    The primary objective of this study was to obtain basic, descriptive information about medical physicists involved in diagnostic radiology-related activities, the diagnostic-related activities that they performed, and the time spent on these activities. A survey was sent to a randomly selected sample of 1511 medical physicists from July through October 2001 using primarily e-mail methods; a total of 851 surveys was received, for a response rate of 56%. Of these, 427 were responses from physicists who do partly or only clinical diagnostic medical physics; it is this group for which results are presented. Fifty-four percent of the physicists who reported doing any clinical diagnostic medical physics performed clinical activities only in diagnostic medical physics. Fourteen percent of all those doing clinical diagnostic medical physics were women. Over 97% of the physicists doing clinical diagnostic medical physics reported having graduate degrees in physics; 53% had PhDs. The mean total weekly hours worked by physicists doing clinical diagnostic medical physics was 42. Medical physicists doing only clinical diagnostic activities reported working approximately 40 hours weekly, whereas those doing partly clinical diagnostic medical physics reported working 14 hours weekly in the field (approximately one-third of their work time). Radiography and fluoroscopy, computed tomography, nuclear medicine, and mammography are all fields in which the majority of those doing any clinical diagnostic medical physics are active. Full-time physicists working only in diagnostic medical physics were responsible for a median of 25 units of equipment, compared with a median of 10 units for those working only partly in the field. Number of units evaluated, frequency of evaluation, and hours per evaluation were reported for almost 20 types of equipment. Medical physicists performing diagnostic clinical activities typically are responsible for a large number and wide variety of imaging equipment. It would be helpful to study their work further, focusing in particular on whether there is a shortage, as is true of diagnostic radiologists, and whether the variety of responsibilities creates strain.

  8. [Influence of antitumor system rhenium-platinum on biochemical state of the liver].

    PubMed

    Ivchuk, V V; Polishko, T M; Golichenko, O A; Shtemenko, O V; Shtemenko, N I

    2011-01-01

    Influence of the antitumour rhenium-platinum system on biochemical liver characteristics in the model of tumor growth (Guerin carcinoma) was studied and possible hepatoprotective activity of rhenium cluster compounds when introducing them in different forms was shown, that was confirmed by decreasing of diagnostic enzymes activity in blood (aminotransferase--AST 6 times and ALT 5.6 times, lactatedehydrogenase 4.9 times, gamma-glutamyltranspeptidase 3.6 times) and normalization of morphological state of the liver cells. The hepatoprotective activity of the cluster rhenium compound with adamanthyl ligands was confirmed in the model of acute toxic hepatitis. Introduction of this compound led to reduction of the concentration of MDA in homogenates of liver tissue (2 times), and in blood plasma (3.8 times); to reduction of levels of diagnostic liver enzymes in blood--AST and ALT 5.8 and 5.5 times respectively in comparison with control group. Some aspects of the mechanism of hepatoprotection were discussed, that included the presence of conjugated systems around the quadrupol rhenium-rhenium bond and alkyl radicals with significant positive inductive effects.

  9. Studying the Impact of Spaceflight Environment on Immune Functions Using New Molecular Diagnostics System

    NASA Astrophysics Data System (ADS)

    Cohen, Luchino

    Immune functions are altered during space flights. Latent virus reactivation, reduction in the number of immune cells, decreased cell activation and increased sensitivity of astronauts to infections following their return on Earth demonstrate that the immune system is less efficient during space flight. The causes of this immune deficiency are not fully understood and this dysfunction during long-term missions could result in the appearance of opportunistic infections or a decrease in the immuno-surveillance mechanisms that eradicate cancer cells. Therefore, the immune functions of astronauts will have to be monitored continuously during long-term missions in space, using miniature and semi-automated diagnostic systems. The objectives of this project are to study the causes of space-related immunodeficiency, to develop countermeasures to maintain an optimal immune function and to improve our capacity to detect infectious diseases during space missions through the monitoring of astronauts' immune system. In order to achieve these objectives, an Immune Function Diagnostic System (IFDS) will be designed to perform a set of immunological assays on board spacecrafts or on planet-bound bases. Through flow cytometric assays and molecular biology analyses, this diagnostic system could improve medical surveillance of astronauts and could be used to test countermeasures aimed at preventing immune deficiency during space missions. The capacity of the instrument to assess cellular fluorescence and to quantify the presence of soluble molecules in biological samples would support advanced molecular studies in space life sciences. Finally, such diagnostic system could also be used on Earth in remote areas or in mobile hospitals following natural disasters to fight against infectious diseases and other pathologies.

  10. [The characteristics of medical technologies in emergency medical care hospital].

    PubMed

    Murakhovskiĭ, A G; Babenko, A I; Bravve, Iu I; Tataurova, E A

    2013-01-01

    The article analyzes the implementation of major 12 diagnostic and 17 treatment technologies applied during medical care of patients with 12 key nosology forms of diseases in departments of the emergency medical care hospital No 2 of Omsk. It is established that key groups of technologies in the implementation of diagnostic process are the laboratory clinical diagnostic analyses and common diagnostic activities at reception into hospital and corresponding departments. The percentage of this kind of activities is about 78.3% of all diagnostic technologies. During the realization of treatment process the priority technologies are common curative and rehabilitation activities, intensive therapy activities and clinical diagnostic monitoring activities. All of them consist 80.1% of all curative technologies.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, M. C., E-mail: mthompson@trialphaenergy.com; Gota, H.; Putvinski, S.

    The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions ofmore » the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.« less

  12. Optical sensors for electrical elements of a medium voltage distribution network

    NASA Astrophysics Data System (ADS)

    De Maria, Letizia; Bartalesi, Daniele; Serragli, Paolo; Paladino, Domenico

    2012-04-01

    The aging of most of the components of the National transmission and distribution system can potentially influence the reliability of power supply in a Medium Voltage (MV) network. In order to prevent possible dangerous situations, selected diagnostic indicators on electrical parts exploiting reliable and potentially low-cost sensors are required. This paper presents results concerning two main research activities regarding the development and application of innovative optical sensors for the diagnostic of MV electrical components. The first concerns a multi-sensor prototype for the detection of pre-discharges in MV switchboards: it is the combination of three different types of sensors operating simultaneously to detect incipient failure and to reduce the occurrence of false alarms. The system is real-time controlled by an embedded computer through a LabView interface. The second activity refers to a diagnostic tool to provide significant real-time information about early aging of MV/Low Voltage (LV) transformers by means of its vibration fingerprint. A miniaturized Optical Micro-Electro-Mechanical System (MEMS) based unit has been assembled for vibration measurements, wireless connected to a remote computer and controlled via LabView interface. Preliminary comparative tests were carried out with standard piezoelectric accelerometers on a conventional MV/LV test transformer under open circuit and in short-circuited configuration.

  13. Update on the status of the ITER ECE diagnostic design

    NASA Astrophysics Data System (ADS)

    Taylor, G.; Austin, M. E.; Basile, A.; Beno, J. H.; Danani, S.; Feder, R.; Houshmandyar, S.; Hubbard, A. E.; Johnson, D. W.; Khodak, A.; Kumar, R.; Kumar, S.; Ouroua, A.; Padasalagi, S. B.; Pandya, H. K. B.; Phillips, P. E.; Rowan, W. L.; Stillerman, J.; Thomas, S.; Udintsev, V. S.; Vayakis, G.; Walsh, M.; Weeks, D.

    2017-07-01

    Considerable progress has been made on the design of the ITER electron cyclotron emission (ECE) diagnostic over the past two years. Radial and oblique views are still included in the design in order to measure distortions in the electron momentum distribution, but the oblique view has been redirected to reduce stray millimeter radiation from the electron cyclotron heating system. A major challenge has been designing the 1000 K calibration sources and remotely activated mirrors located in the ECE diagnostic shield module (DSM) in the equatorial port plug #09. These critical systems are being modeled and prototypes are being developed. Providing adequate neutron shielding in the DSM while allowing sufficient space for optical components is also a significant challenge. Four 45-meter long low-loss transmission lines transport the 70-1000 GHz ECE from the DSM to the ECE instrumentation room. Prototype transmission lines are being tested, as are the polarization splitter modules that separate O-mode and X-mode polarized ECE. A highly integrated prototype 200-300 GHz radiometer is being tested on the DIII-D tokamak in the USA. Design activities also include integration of ECE signals into the ITER plasma control system and determining the hardware and software architecture needed to control and calibrate the ECE instruments.

  14. Battling Malaria in Rural Zambia with Modern Technology: A Qualitative Study on the Value of Cell Phones, Geographical Information Systems, Asymptomatic Carriers and Rapid Diagnostic Tests to Identify, Treat and Control Malaria.

    PubMed

    Nygren, David; Isaksson, Arvid Lissel

    2014-02-04

    During the last decade much progress has been made in reducing malaria transmission in Macha, Southern Province, Zambia. Introduction of artemisinin combination therapies as well as mass screenings of asymptomatic carriers is believed to have contributed the most. When an endemic malaria situation is moving towards a non-endemic situation the resident population loses acquired immunity and therefore active case detection and efficient surveillance is crucial to prevent epidemic outbreaks. Our purpose was to evaluate the impact of cell phone surveillance and geographical information systems on malaria control in Macha. Furthermore, it evaluates what screening and treatment of asymptomatic carriers and implementation of rapid diagnostic tests in rural health care has led to. Ten in-depth semi-structured interviews, field observations and data collection were performed at the Macha Research Trust and at surrounding rural health centers. This qualitative method was inspired by rapid assessment procedure. The cell phone surveillance has been easily integrated in health care, and its integration with Geographical Information Systems has provided the ability to follow malaria transmission on a weekly basis. In addition, active case detection of asymptomatic carriers has been fruitful, which is reflected in it soon being applied nationwide. Furthermore, rapid diagnostic tests have provided rural health centers with reliable malaria diagnostics, thereby decreasing excessive malaria treatments and selection for drug resistance. This report reflects the importance of asymptomatic carriers in targeting malaria elimination, as well as development of effective surveillance systems when transmission decreases. Such an approach would be cost-efficient in the long run through positive effects in reduced child mortality and relief in health care.

  15. Measures to Improve Diagnostic Safety in Clinical Practice

    PubMed Central

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-01-01

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of “diagnostic safety” related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety, and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm. PMID:27768655

  16. [Clinical picture, diagnostics and prophylaxis of a syndrome in conditions of the Far North].

    PubMed

    Ukhocskiĭ, D M; Tegza, V Iu; Rezvantsev, M V; Vasil'chenko, V V; Belikova, T M

    2014-10-01

    The analysis of a clinical picture barometeosensitivity in a seaside zone of the Far North is carried out in the article. A diagnostic test included the following laboratory assessments: complete blood count, complete urinary analysis, biomedical measurement assessment, immunology blood research and functional renal test; analysis of the level of an electrolyte in the blood and hormone receptor status; and the following instrumental diagnostics: The auscultatory Korotkov's method of determining blood pressure, electrocardiography, variational pulsometry, chest X-ray, mechanocardiography, echocardiography and abdominal ultrasound; and also consultation of ophthalmologist and neuropathologist. Every patient should keep a diary "weather - health" before and after the treatment. Peculiarities of cardiovascular system, vegetative systems and neuroendocrine system of servicemen, coming to the Far North and mechanisms of development of barometeosensivity were revealed. It has been established that atmospheric pressure variation affects systolic and diastolic blood pressure, heart rate, systolic discharge, Kerdo index, effectiveness of myocardial function, end-diastolic and end-systolic volume, level of cholesterol, triglycerides, kalium, adrenalin, triiodothyronine, blood plasma and plasma renin activity in barometeosensetiv servicemen. The criteria of diagnostics of barometeosensivity in conditions of the Far North are suggested. The influence of baromemteosensivity on the combat capability of serviceman is researched.

  17. Engineering aspects of design and integration of ECE diagnostic in ITER

    DOE PAGES

    Udintsev, V. S.; Taylor, G.; Pandya, H. K.B.; ...

    2015-03-12

    ITER ECE diagnostic [1] needs not only to meet measurement requirements, but also to withstand various loads, such as electromagnetic, mechanical, neutronic and thermal, and to be protected from stray ECH radiation at 170 GHz and other millimeter wave emission, like Collective Thomson scattering which is planned to operate at 60 GHz. Same or similar loads will be applied to other millimetre-wave diagnostics [2], located both in-vessel and in-port plugs. These loads must be taken into account throughout the design phases of the ECE and other microwave diagnostics to ensure their structural integrity and maintainability. The integration of microwave diagnosticsmore » with other ITER systems is another challenging activity which is currently ongoing through port integration and in-vessel integration work. Port Integration has to address the maintenance and the safety aspects of diagnostics, too. Engineering solutions which are being developed to support and to operate ITER ECE diagnostic, whilst complying with safety and maintenance requirements, are discussed in this paper.« less

  18. Means of processing information on motor activity of patient during sleep

    NASA Astrophysics Data System (ADS)

    Gorbunov, A. V.; Egorov, V. S.; Neprokin, A. V.

    2018-05-01

    Information about the physical activity of a person during sleep is an important component of information about the state of one’s nervous system, the interpretation of which can be used for disease monitoring, diagnostics and prediction of diseases of the nervous system. This will significantly reduce the risks of disability and improve the quality of life of the patient in accordance with the concept of mobile telemedicine (mHealth).

  19. A design and implementation methodology for diagnostic systems

    NASA Technical Reports Server (NTRS)

    Williams, Linda J. F.

    1988-01-01

    A methodology for design and implementation of diagnostic systems is presented. Also discussed are the advantages of embedding a diagnostic system in a host system environment. The methodology utilizes an architecture for diagnostic system development that is hierarchical and makes use of object-oriented representation techniques. Additionally, qualitative models are used to describe the host system components and their behavior. The methodology architecture includes a diagnostic engine that utilizes a combination of heuristic knowledge to control the sequence of diagnostic reasoning. The methodology provides an integrated approach to development of diagnostic system requirements that is more rigorous than standard systems engineering techniques. The advantages of using this methodology during various life cycle phases of the host systems (e.g., National Aerospace Plane (NASP)) include: the capability to analyze diagnostic instrumentation requirements during the host system design phase, a ready software architecture for implementation of diagnostics in the host system, and the opportunity to analyze instrumentation for failure coverage in safety critical host system operations.

  20. Development of an intelligent diagnostic system for reusable rocket engine control

    NASA Technical Reports Server (NTRS)

    Anex, R. P.; Russell, J. R.; Guo, T.-H.

    1991-01-01

    A description of an intelligent diagnostic system for the Space Shuttle Main Engines (SSME) is presented. This system is suitable for incorporation in an intelligent controller which implements accommodating closed-loop control to extend engine life and maximize available performance. The diagnostic system architecture is a modular, hierarchical, blackboard system which is particularly well suited for real-time implementation of a system which must be repeatedly updated and extended. The diagnostic problem is formulated as a hierarchical classification problem in which the failure hypotheses are represented in terms of predefined data patterns. The diagnostic expert system incorporates techniques for priority-based diagnostics, the combination of analytical and heuristic knowledge for diagnosis, integration of different AI systems, and the implementation of hierarchical distributed systems. A prototype reusable rocket engine diagnostic system (ReREDS) has been implemented. The prototype user interface and diagnostic performance using SSME test data are described.

  1. Online Monitoring To Enable Improved Diagnostics, Prognostics and Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, Leonard J.

    2011-08-31

    Only time will tell what the implications of the Fukushima incident will be. Discussions are on-going with regard to continued operation and life extension of the existing fleet, new build, and the wider policy issues including technologies needed to address spent fuel storage and ensure energy security, and the related desires to provide sustainable energy systems while at the same time limiting greenhouse gas emissions. The science base for advanced diagnostics and prognostics to support its use in nuclear power plants (NPPs) for active components (pumps, valves etc) has been demonstrated. A challenge is enabling adaption of these technologies formore » NPP deployment and the validation of the data from these technologies. Advanced diagnostics, monitoring and prognostics applied to passive structures, which in the USA context of longer term operation is up to 80 years, are being researched. Early laboratory work is demonstrating the potential for these methods, although technical challenges remain. It can be expected that there will be an increased need for and use of on-line monitoring for a wide range of both active and passive systems in all types of nuclear power plants.« less

  2. Recent results of PADReS, the Photon Analysis Delivery and REduction System, from the FERMI FEL commissioning and user operations.

    PubMed

    Zangrando, Marco; Cocco, Daniele; Fava, Claudio; Gerusina, Simone; Gobessi, Riccardo; Mahne, Nicola; Mazzucco, Eric; Raimondi, Lorenzo; Rumiz, Luca; Svetina, Cristian

    2015-05-01

    The Photon Analysis Delivery and REduction System of FERMI (PADReS) has been routinely used during the machine commissioning and operations of FERMI since 2011. It has also served the needs of several user runs at the facility from late 2012. The system is endowed with online and shot-to-shot diagnostics giving information about intensity, spatial-angular distribution, spectral content, as well as other diagnostics to determine coherence, pulse length etc. Moreover, PADReS is capable of manipulating the beam in terms of intensity and optical parameters. Regarding the optics, besides a standard refocusing system based on an ellipsoidal mirror, the Kirkpatrick-Baez active optics systems are key elements and have been used intensively to meet users' requirements. A general description of the system is given, together with some selected results from the commissioning/operations/user beam time.

  3. Characterization of the Auroral Electrojet and the Ambient and Modified D Region for HAARP Using Long-Path VLF Diagnostics

    DTIC Science & Technology

    2001-03-15

    order to characterize the auroral electrojet and the ambient and modified D-region directly above and near the HAARP (High Frequency Active Auroral...near the HAARP facility and along the west coast of Alaska. In addition in order to characterize the auroral electrojet on a continental scale and to...United States and Canada. Data from the complete array of D-region diagnostic systems was acquired during a number of Fall and Spring HAARP campaigns

  4. Leishmania Surveillance and Diagnostic Capability in Support of the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and Leishmania Vector Surveillance

    DTIC Science & Technology

    2013-02-07

    specific biosurveillance activities as well as clinical applications and alternative versions preformatted and categorized as ‘high-tech’ and ‘low-tech’ and...methodologies. Application for patent protection of this DoD intellectual property is underway. 1::1 . :::.u~~l-1 I ~111VI:::O Leishmaniasis...LHL assay and the need to develop novel and unique sample preparation methodologies. Application for patent protection of this DoD intellectual

  5. Integrated control system for electron beam processes

    NASA Astrophysics Data System (ADS)

    Koleva, L.; Koleva, E.; Batchkova, I.; Mladenov, G.

    2018-03-01

    The ISO/IEC 62264 standard is widely used for integration of the business systems of a manufacturer with the corresponding manufacturing control systems based on hierarchical equipment models, functional data and manufacturing operations activity models. In order to achieve the integration of control systems, formal object communication models must be developed, together with manufacturing operations activity models, which coordinate the integration between different levels of control. In this article, the development of integrated control system for electron beam welding process is presented as part of a fully integrated control system of an electron beam plant, including also other additional processes: surface modification, electron beam evaporation, selective melting and electron beam diagnostics.

  6. An update on the use of cerebrospinal fluid analysis as a diagnostic tool in multiple sclerosis.

    PubMed

    Gastaldi, Matteo; Zardini, Elisabetta; Franciotta, Diego

    2017-01-01

    Intrathecal B-lymphocyte activation is a hallmark of multiple sclerosis (MS), a multi-factorial inflammatory-demyelinating disease of the central nervous system. Such activation has a counterpart in the cerebrospinal fluid (CSF) oligoclonal IgG bands (OCB), whose diagnostic role in MS has been downgraded within the current McDonald's criteria. With a theoretico-practical approach, the authors review the physiopathological basis of the CSF dynamics, and the state-of-the-art of routine CSF analysis and CSF biomarkers in MS. Areas covered: The authors discuss pros and cons of CSF analysis, including critical evaluations of both well-established, and promising diagnostic and prognostic laboratory tools. New acquisitions on the CSF and cerebral interstitial fluid dynamics are also presented. The authors searched the PubMed database for English-language articles reported between January 2010 and June 2016, using the key words 'multiple sclerosis', 'cerebrospinal fluid', 'oligoclonal bands'. Reference lists of relevant articles were scanned for additional studies. Expert commentary: The availability of performing high-quality, routine CSF tests in specialized laboratories, the emerging potential of novel CSF biomarkers, and the trend for early treatments should induce a reappraisal of CSF analysis for diagnostic and prognostic purposes in MS. Further procedural and methodological improvements seem to be necessary in both research and translational diagnostic CSF settings.

  7. An Overview of Prognosis Health Management Research at Glenn Research Center for Gas Turbine Engine Structures With Special Emphasis on Deformation and Damage Modeling

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M.; Goldberg, Robert K.; Lerch, Bradley A.; Saleeb, Atef F.

    2009-01-01

    Herein a general, multimechanism, physics-based viscoelastoplastic model is presented in the context of an integrated diagnosis and prognosis methodology which is proposed for structural health monitoring, with particular applicability to gas turbine engine structures. In this methodology, diagnostics and prognostics will be linked through state awareness variable(s). Key technologies which comprise the proposed integrated approach include (1) diagnostic/detection methodology, (2) prognosis/lifing methodology, (3) diagnostic/prognosis linkage, (4) experimental validation, and (5) material data information management system. A specific prognosis lifing methodology, experimental characterization and validation and data information management are the focal point of current activities being pursued within this integrated approach. The prognostic lifing methodology is based on an advanced multimechanism viscoelastoplastic model which accounts for both stiffness and/or strength reduction damage variables. Methods to characterize both the reversible and irreversible portions of the model are discussed. Once the multiscale model is validated the intent is to link it to appropriate diagnostic methods to provide a full-featured structural health monitoring system.

  8. An Overview of Prognosis Health Management Research at GRC for Gas Turbine Engine Structures With Special Emphasis on Deformation and Damage Modeling

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M.; Goldberg, Robert K.; Lerch, Bradley A.; Saleeb, Atef F.

    2009-01-01

    Herein a general, multimechanism, physics-based viscoelastoplastic model is presented in the context of an integrated diagnosis and prognosis methodology which is proposed for structural health monitoring, with particular applicability to gas turbine engine structures. In this methodology, diagnostics and prognostics will be linked through state awareness variable(s). Key technologies which comprise the proposed integrated approach include 1) diagnostic/detection methodology, 2) prognosis/lifing methodology, 3) diagnostic/prognosis linkage, 4) experimental validation and 5) material data information management system. A specific prognosis lifing methodology, experimental characterization and validation and data information management are the focal point of current activities being pursued within this integrated approach. The prognostic lifing methodology is based on an advanced multi-mechanism viscoelastoplastic model which accounts for both stiffness and/or strength reduction damage variables. Methods to characterize both the reversible and irreversible portions of the model are discussed. Once the multiscale model is validated the intent is to link it to appropriate diagnostic methods to provide a full-featured structural health monitoring system.

  9. Optical Diagnostic System for Solar Sails: Phase 1 Final Report

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Blandino, Joseph R.; Caldwell, Douglas W.; Carroll, Joseph A.; Jenkins, Christopher H. M.; Pollock, Thomas C.

    2004-01-01

    NASA's In-Space Propulsion program recently selected AEC-ABLE Engineering and L'Garde, Inc. to develop scale-model solar sail hardware and demonstrate its functionality on the ground. Both are square sail designs with lightweight diagonal booms (<100 g/m) and ultra-thin membranes (<10 g/sq m). To support this technology, the authors are developing an integrated diagnostics instrumentation package for monitoring solar sail structures such as these in a near-term flight experiment. We refer to this activity as the "Optical Diagnostic System (ODS) for Solar Sails" project. The approach uses lightweight optics and photogrammetric techniques to measure solar sail membrane and boom shape and dynamics, thermography to map temperature, and non-optical sensors including MEMS accelerometers and load cells. The diagnostics package must measure key structural characteristics including deployment dynamics, sail support tension, boom and sail deflection, boom and sail natural frequencies, sail temperature, and sail integrity. This report summarizes work in the initial 6-month Phase I period (conceptual design phase) and complements the final presentation given in Huntsville, AL on January 14, 2004.

  10. Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist.

    PubMed

    Delis, H; Christaki, K; Healy, B; Loreti, G; Poli, G L; Toroi, P; Meghzifene, A

    2017-09-01

    Quality control (QC), according to ISO definitions, represents the most basic level of quality. It is considered to be the snapshot of the performance or the characteristics of a product or service, in order to verify that it complies with the requirements. Although it is usually believed that "the role of medical physicists in Diagnostic Radiology is QC", this, not only limits the contribution of medical physicists, but is also no longer adequate to meet the needs of Diagnostic Radiology in terms of Quality. In order to assure quality practices more organized activities and efforts are required in the modern era of diagnostic radiology. The complete system of QC is just one element of a comprehensive quality assurance (QA) program that aims at ensuring that the requirements of quality of a product or service will consistently be fulfilled. A comprehensive Quality system, starts even before the procurement of any equipment, as the need analysis and the development of specifications are important components under the QA framework. Further expanding this framework of QA, a comprehensive Quality Management System can provide additional benefits to a Diagnostic Radiology service. Harmonized policies and procedures and elements such as mission statement or job descriptions can provide clarity and consistency in the services provided, enhancing the outcome and representing a solid platform for quality improvement. The International Atomic Energy Agency (IAEA) promotes this comprehensive quality approach in diagnostic imaging and especially supports the field of comprehensive clinical audits as a tool for quality improvement. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. [Description of the mental processes occurring during clinical reasoning].

    PubMed

    Pottier, P; Planchon, B

    2011-06-01

    Clinical reasoning is a highly complex system with multiple inter-dependent mental activities. Gaining a better understanding of those cognitive processes has two practical implications: for physicians, being able to analyse their own reasoning method may prove to be helpful in diagnostic dead end; for medical teachers, identifying problem-solving strategies used by medical students may foster an appropriate individual feed-back aiming at improving their clinical reasoning skills. On the basis of a detailed literature review, the main diagnostic strategies and their related pattern of mental processes are described and illustrated with a concrete example, going from the patient's complaint to the chosen solution. Inductive, abductive and deductive diagnostic approaches are detailed. Different strategies for collecting data (exhaustive or oriented) and for problem-building are described. The place of problem solving strategies such as pattern-recognition, scheme inductive process, using of clinical script, syndrome grouping and mental hypotheses test is considered. This work aims at breaking up mental activities in process within clinical reasoning reminding that expert reasoning is characterised by the ability to use and structure the whole of these activities in a coherent system, using combined strategies in order to guarantee a better accuracy of their diagnosis. Copyright © 2010 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  12. New chemical probe technologies: applications to imaging and drug discovery (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bogyo, Matthew

    2017-02-01

    Proteases are enzymes that play pathogenic roles in many common human diseases such as cancer, asthma, arthritis, atherosclerosis and infection by pathogens. Tools to dynamically monitor their activity can be used as diagnostic agents, as imaging contrast agents for intra-operative image guidance and for the identification of novel classes of protease-targeted drugs. I will describe our efforts to design and synthesize small molecule probes that produce a fluorescent signal upon binding to a protease target. We have identified probes that show tumor-specific retention, fast activation kinetics, and rapid systemic distribution making them useful for real-time fluorescence guided tumor resection and other diagnostic imaging applications.

  13. FIBER AND INTEGRATED OPTICS. OTHER TOPICS IN QUANTUM ELECTRONICS: Determination of the saturation parameter in a fast-flow CO2 active medium

    NASA Astrophysics Data System (ADS)

    Lebedev, V. F.; Lysikov, A. Yu; Ryazanova, A. V.; Shalygin, S. V.

    1990-05-01

    A diagnostic method was developed for determination of such an important characteristic of a CO2 active medium as the energy stored in the vibrational degrees of freedom of molecules, which can be determined directly from the experimentally measured powers of probe beams without the need for any additional information on the medium and without any numerical calculations. Measurements were carried out using a real fast-flow system, which satisfied the conditions of validity of the proposed diagnostic method, and the correctness of the approach was confirmed. The results obtained demonstrated the efficiency of the excitation of the medium when the pump conditions were varied.

  14. Nuclear Diagnostics at the National Ignition Facility, 2013-2015

    NASA Astrophysics Data System (ADS)

    Yeamans, C. B.; Cassata, W. S.; Church, J. A.; Fittinghoff, D. N.; Gatu Johnson, M.; Gharibyan, N.; Határik, R.; Sayre, D. B.; Sio, H. W.; Bionta, R. M.; Bleuel, D. L.; Caggiano, J. A.; Cerjan, C. J.; Cooper, G. W.; Eckart, M. J.; Edwards, E. R.; Faye, S. A.; Forrest, C. J.; Frenje, J. A.; Glebov, V. Yu; Grant, P. M.; Grim, G. P.; Hartouni, E. P.; Herrmann, H. W.; Kilkenny, J. D.; Knauer, J. P.; Mackinnon, A. J.; Merrill, F. E.; Moody, K. J.; Moran, M. J.; Petrasso, R. D.; Phillips, T. W.; Rinderknecht, H. G.; Schneider, D. H. G.; Sepke, S. M.; Shaughnessy, D. A.; Stoeffl, W.; Velsko, C. A.; Volegov, P.

    2016-05-01

    The National Ignition Facility (NIF) relies on a suite of nuclear diagnostics to measure the neutronic output of experiments. Neutron time-of-flight (NTOF) and neutron activation diagnostics (NAD) provide performance metrics of absolute neutron yield and neutron spectral content: spectral width and non-thermal content, from which implosion physical quantities of temperature and scattering mass are inferred. Spatially-distributed flange- mounted NADs (FNAD) measure, with nearly identical systematic uncertainties, primary DT neutron emission to infer a whole-sky neutron field. An automated FNAD system is being developed. A magnetic recoil spectrometer (MRS) shares few systematics with comparable NTOF and NAD devices, and as such is deployed for independent measurement of the primary neutronic quantities. The gas-Cherenkov Gamma Reaction History (GRH) instrument records four energy channels of time-resolved gamma emission to measure nuclear bang time and burn width, as well as to infer carbon areal density in experiments utilizing plastic or diamond capsules. A neutron imaging system (NIS) takes two images of the neutron source, typically gated to create coregistered 13-15 MeV primary and 6-12 MeV downscattered images. The radiochemical analysis of gaseous samples (RAGS) instrument pumps target chamber gas to a chemical reaction and fractionation system configured with gamma counters, allowing measurement of radionuclides with half-lives as short as 8 seconds. Solid radiochemistry collectors (SRC) with backing NAD foils collect target debris, where activated materials from the target assembly are used as indicators of neutron spectrum content, and also serve as the primary diagnostic for nuclear forensic science experiments. Particle time-of-flight (PTOF) measures compression-bang time using DT- or DD-neutrons, as well as shock bang-time using D3He-protons for implosions with lower x-ray background. In concert, these diagnostics serve to measure the basic and advanced quantities required to understand NIF experimental results.

  15. Development of departmental standard for traceability of measured activity for I-131 therapy capsules used in nuclear medicine.

    PubMed

    Ravichandran, Ramamoorthy; Binukumar, Jp

    2011-01-01

    International Basic Safety Standards (International Atomic Energy Agency, IAEA) provide guidance levels for diagnostic procedures in nuclear medicine indicating the maximum usual activity for various diagnostic tests in terms of activities of injected radioactive formulations. An accuracy of ± 10% in the activities of administered radio-pharmaceuticals is being recommended, for expected outcome in diagnostic and therapeutic nuclear medicine procedures. It is recommended that the long-term stability of isotope calibrators used in nuclear medicine is to be checked periodically for their performance using a long-lived check source, such as Cs-137, of suitable activity. In view of the un-availability of such a radioactive source, we tried to develop methods to maintain traceability of these instruments, for certifying measured activities for human use. Two re-entrant chambers [(HDR 1000 and Selectron Source Dosimetry System (SSDS)] with I-125 and Ir-192 calibration factors in the Department of Radiotherapy were used to measure Iodine-131 (I-131) therapy capsules to establish traceability to Mark V isotope calibrator of the Department of Nuclear Medicine. Special nylon jigs were fabricated to keep I-131 capsule holder in position. Measured activities in all the chambers showed good agreement. The accuracy of SSDS chamber in measuring Ir-192 activities in the last 5 years was within 0.5%, validating its role as departmental standard for measuring activity. The above method is adopted because mean energies of I-131 and Ir-192 are comparable.

  16. Meeting the Challenges of Exploration Systems: Health Management Technologies for Aerospace Systems With Emphasis on Propulsion

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Sowers, T. Shane; Maul, William A.

    2005-01-01

    The constraints of future Exploration Missions will require unique Integrated System Health Management (ISHM) capabilities throughout the mission. An ambitious launch schedule, human-rating requirements, long quiescent periods, limited human access for repair or replacement, and long communication delays all require an ISHM system that can span distinct yet interdependent vehicle subsystems, anticipate failure states, provide autonomous remediation, and support the Exploration Mission from beginning to end. NASA Glenn Research Center has developed and applied health management system technologies to aerospace propulsion systems for almost two decades. Lessons learned from past activities help define the approach to proper ISHM development: sensor selection- identifies sensor sets required for accurate health assessment; data qualification and validation-ensures the integrity of measurement data from sensor to data system; fault detection and isolation-uses measurements in a component/subsystem context to detect faults and identify their point of origin; information fusion and diagnostic decision criteria-aligns data from similar and disparate sources in time and use that data to perform higher-level system diagnosis; and verification and validation-uses data, real or simulated, to provide variable exposure to the diagnostic system for faults that may only manifest themselves in actual implementation, as well as faults that are detectable via hardware testing. This presentation describes a framework for developing health management systems and highlights the health management research activities performed by the Controls and Dynamics Branch at the NASA Glenn Research Center. It illustrates how those activities contribute to the development of solutions for Integrated System Health Management.

  17. Continued Development of Expert System Tools for NPSS Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Lewandowski, Henry

    1996-01-01

    The objectives of this grant were to work with previously developed NPSS (Numerical Propulsion System Simulation) tools and enhance their functionality; explore similar AI systems; and work with the High Performance Computing Communication (HPCC) K-12 program. Activities for this reporting period are briefly summarized and a paper addressing the implementation, monitoring and zooming in a distributed jet engine simulation is included as an attachment.

  18. Feasibility Investigation on the Development of a Structural Damage Diagnostic and Monitoring System for Rocket Engines

    NASA Technical Reports Server (NTRS)

    Shen, Ji Y.; Sharpe, Lonnie, Jr.

    1998-01-01

    The research activity for this project is mainly to investigate the necessity and feasibility to develop a structural health monitoring system for rocket engines, and to carry out a research plan for further development of the system. More than one hundred technical papers have been searched and reviewed during the period. We concluded after this investigation that adding a new module in NASA's existing automated diagnostic system to monitor the healthy condition of rocket engine structures is a crucial task, and it's possible to develop such a system based upon the vibrational-based nondestructive damage assessment techniques. A number of such techniques have been introduced. Their advantages and disadvantages are also discussed. A global research plan has been figured out. As the first step of the overall research plan, a proposal for the next fiscal year has been submitted.

  19. The way to universal and correct medical presentation of diagnostic informations for complex spectrophotometry noninvasive medical diagnostic systems

    NASA Astrophysics Data System (ADS)

    Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.

    2003-07-01

    The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.

  20. Clinical data miner: an electronic case report form system with integrated data preprocessing and machine-learning libraries supporting clinical diagnostic model research.

    PubMed

    Installé, Arnaud Jf; Van den Bosch, Thierry; De Moor, Bart; Timmerman, Dirk

    2014-10-20

    Using machine-learning techniques, clinical diagnostic model research extracts diagnostic models from patient data. Traditionally, patient data are often collected using electronic Case Report Form (eCRF) systems, while mathematical software is used for analyzing these data using machine-learning techniques. Due to the lack of integration between eCRF systems and mathematical software, extracting diagnostic models is a complex, error-prone process. Moreover, due to the complexity of this process, it is usually only performed once, after a predetermined number of data points have been collected, without insight into the predictive performance of the resulting models. The objective of the study of Clinical Data Miner (CDM) software framework is to offer an eCRF system with integrated data preprocessing and machine-learning libraries, improving efficiency of the clinical diagnostic model research workflow, and to enable optimization of patient inclusion numbers through study performance monitoring. The CDM software framework was developed using a test-driven development (TDD) approach, to ensure high software quality. Architecturally, CDM's design is split over a number of modules, to ensure future extendability. The TDD approach has enabled us to deliver high software quality. CDM's eCRF Web interface is in active use by the studies of the International Endometrial Tumor Analysis consortium, with over 4000 enrolled patients, and more studies planned. Additionally, a derived user interface has been used in six separate interrater agreement studies. CDM's integrated data preprocessing and machine-learning libraries simplify some otherwise manual and error-prone steps in the clinical diagnostic model research workflow. Furthermore, CDM's libraries provide study coordinators with a method to monitor a study's predictive performance as patient inclusions increase. To our knowledge, CDM is the only eCRF system integrating data preprocessing and machine-learning libraries. This integration improves the efficiency of the clinical diagnostic model research workflow. Moreover, by simplifying the generation of learning curves, CDM enables study coordinators to assess more accurately when data collection can be terminated, resulting in better models or lower patient recruitment costs.

  1. SMART Layer and SMART Suitcase for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Lin, Mark; Qing, Xinlin; Kumar, Amrita; Beard, Shawn J.

    2001-06-01

    Knowledge of integrity of in-service structures can greatly enhance their safety and reliability and lower structural maintenance cost. Current practices limit the extent of real-time knowledge that can be obtained from structures during inspection, are labor-intensive and thereby increase life-cycle costs. Utilization of distributed sensors integrated with the structure is a viable and cost-effective means of monitoring the structure and reducing inspection costs. Acellent Technologies is developing a novel system for actively and passively interrogating the health of a structure through an integrated network of sensors and actuators. Acellent's system comprises of SMART Layers, SMART Suitcase and diagnostic software. The patented SMART Layer is a thin dielectric film with an embedded network of distributed piezoelectric actuators/sensors that can be surface-mounted on metallic structures or embedded inside composite structures. The SMART Suitcase is a portable diagnostic unit designed with multiple sensor/actuator channels to interface with the SMART Layer, generate diagnostic signals from actuators and record measurements from the embedded sensors. With appropriate diagnostic software, Acellent's system can be used for monitoring structural condition and for detecting damage while the structures are in service. This paper enumerates on the SMART Layer and SMART Suitcase and their applicability to composite and metal structures.

  2. Lunar Surface Reference Missions: A Description of Human and Robotic Surface Activities

    NASA Technical Reports Server (NTRS)

    Duke, Michael B.; Hoffman, Stephen J.; Snook, Kelly

    2003-01-01

    Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.

  3. Application of Optical Fibers to DNA’s Testing Program.

    DTIC Science & Technology

    1980-10-15

    economic impact. In addition to benefitting UGT , advances in fiber optic technology can greatly impact other DNA activities such as hardening of military...components and simulation and testing in high radiation environments. Using the UGT environment as a test bed, optical fibers can be characterized in...OPTIC SYSTEMS 33 3-3.1 Active System Design 37 4 USE OF FIBERS IN UGT 47 4-1 ADVANTAGES OF FIBERS FOR UGT 47 4-2 DIAGNOSTIC APPLICATIONS 4-3 EFFECTS

  4. Nonlinear Processing of Auditory Brainstem Response

    DTIC Science & Technology

    2001-10-25

    Kraków, Poland Abstract: - Auditory brainstem response potentials (ABR) are signals calculated from the EEG signals registered as responses to an...acoustic activation of the auditory system. The ABR signals provide an objective, diagnostic method, widely applied in examinations of hearing organs

  5. A diagnostic expert system for aircraft generator control unit (GCU)

    NASA Astrophysics Data System (ADS)

    Ho, Ting-Long; Bayles, Robert A.; Havlicsek, Bruce L.

    The modular VSCF (variable-speed constant-frequency) generator families are described as using standard modules to reduce the maintenance cost and to improve the product's testability. A general diagnostic expert system shell that guides troubleshooting of modules or line replaceable units (LRUs) is introduced. An application of the diagnostic system to a particular LRU, the generator control unit (GCU) is reported. The approach to building the diagnostic expert system is first to capture general diagnostic strategy in an expert system shell. This shell can be easily applied to different devices or LRUs by writing rules to capture only additional device-specific diagnostic information from expert repair personnel. The diagnostic system has the necessary knowledge embedded in its programs and exhibits expertise to troubleshoot the GCU.

  6. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  7. Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Y. L.; Xie, J. L., E-mail: jlxie@ustc.edu.cn; Yu, C. X.

    2016-11-15

    Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven bymore » fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.« less

  8. Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)

    NASA Astrophysics Data System (ADS)

    Zhu, Y. L.; Xie, J. L.; Yu, C. X.; Zhao, Z. L.; Gao, B. X.; Chen, D. X.; Liu, W. D.; Liao, W.; Qu, C. M.; Luo, C.; Hu, X.; Spear, A. G.; Luhmann, N. C.; Domier, C. W.; Chen, M.; Ren, X.; Tobias, B. J.

    2016-11-01

    Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This "4th generation" MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy "general optics structure" has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.

  9. The Feasibility of Classifying Breast Masses Using a Computer-Assisted Diagnosis (CAD) System Based on Ultrasound Elastography and BI-RADS Lexicon.

    PubMed

    Fleury, Eduardo F C; Gianini, Ana Claudia; Marcomini, Karem; Oliveira, Vilmar

    2018-01-01

    To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted κ test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.

  10. Working at the microscope: analysis of the activities involved in diagnostic pathology.

    PubMed

    Randell, Rebecca; Ruddle, Roy A; Quirke, Phil; Thomas, Rhys G; Treanor, Darren

    2012-02-01

    To study the current work practice of histopathologists to inform the design of digital microscopy systems. Four gastrointestinal histopathologists were video-recorded as they undertook their routine work. Analysis of the video data shows a range of activities beyond viewing slides involved in reporting a case. There is much overlapping of activities, supported by the 'eyes free' nature of the pathologists' interaction with the microscope. The order and timing of activities varies according to consultant. In order to support the work of pathologists adequately, digital microscopy systems need to provide support for a range of activities beyond viewing slides. Digital microscopy systems should support multitasking, while also providing flexibility so that pathologists can adapt their use of the technology to their own working patterns. © 2011 Blackwell Publishing Ltd.

  11. Active spectroscopic measurements using the ITER diagnostic system.

    PubMed

    Thomas, D M; Counsell, G; Johnson, D; Vasu, P; Zvonkov, A

    2010-10-01

    Active (beam-based) spectroscopic measurements are intended to provide a number of crucial parameters for the ITER device being built in Cadarache, France. These measurements include the determination of impurity ion temperatures, absolute densities, and velocity profiles, as well as the determination of the plasma current density profile. Because ITER will be the first experiment to study long timescale (∼1 h) fusion burn plasmas, of particular interest is the ability to study the profile of the thermalized helium ash resulting from the slowing down and confinement of the fusion alphas. These measurements will utilize both the 1 MeV heating neutral beams and a dedicated 100 keV hydrogen diagnostic neutral beam. A number of separate instruments are being designed and built by several of the ITER partners to meet the different spectroscopic measurement needs and to provide the maximum physics information. In this paper, we describe the planned measurements, the intended diagnostic ensemble, and we will discuss specific physics and engineering challenges for these measurements in ITER.

  12. Investigation of ionospheric disturbances and associated diagnostic techniques. Final report, 1 January 1992-31 December 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, L.M.

    1995-12-12

    The objectives of this research and development program were to conduct simulation modeling of the generation and propagation of atmospheric acoustic signals associated with surface and subsurface ground disturbances; to construct an experimental measurement system for exploratory research studies of acoustic generated ionospheric disturbances; to model high power radio wave propagation through the ionosphere, including nonlinear wave plasma interaction effects; and to assist in the assessment of diagnostic systems for observation of ionospheric modification experiments using existing and planned high latitude high power RF transmitting facilities. A computer simulation of ionospheric response to ground launched acoustic pulses was constructed andmore » results compared to observational data associated with HF and incoherent scatter radar measurements of ionospheric effects produced by earthquakes and ground level explosions. These results were then utilized to help define the design, construct and test for an HF Doppler radar system. In addition, an assessment was conducted of ionospheric diagnostic instruments proposed for the Air Force/Navy High Frequency Active Auroral Research Program (HAARP).« less

  13. Intelligent approach to prognostic enhancements of diagnostic systems

    NASA Astrophysics Data System (ADS)

    Vachtsevanos, George; Wang, Peng; Khiripet, Noppadon; Thakker, Ash; Galie, Thomas R.

    2001-07-01

    This paper introduces a novel methodology to prognostics based on a dynamic wavelet neural network construct and notions from the virtual sensor area. This research has been motivated and supported by the U.S. Navy's active interest in integrating advanced diagnostic and prognostic algorithms in existing Naval digital control and monitoring systems. A rudimentary diagnostic platform is assumed to be available providing timely information about incipient or impending failure conditions. We focus on the development of a prognostic algorithm capable of predicting accurately and reliably the remaining useful lifetime of a failing machine or component. The prognostic module consists of a virtual sensor and a dynamic wavelet neural network as the predictor. The virtual sensor employs process data to map real measurements into difficult to monitor fault quantities. The prognosticator uses a dynamic wavelet neural network as a nonlinear predictor. Means to manage uncertainty and performance metrics are suggested for comparison purposes. An interface to an available shipboard Integrated Condition Assessment System is described and applications to shipboard equipment are discussed. Typical results from pump failures are presented to illustrate the effectiveness of the methodology.

  14. Dome diagnostics system of optical parameters and characteristics of LEDs

    NASA Astrophysics Data System (ADS)

    Peretyagin, Vladimir S.; Pavlenko, Nikita A.

    2017-09-01

    Scientific and technological progress of recent years in the production of the light emitting diodes (LEDs) has led to the expansion of areas of their application from the simplest systems to high precision lighting devices used in various fields of human activity. However, development and production (especially mass production) of LED lighting devices are impossible without a thorough analysis of its parameters and characteristics. There are many ways and devices for analysis the spatial, energy and colorimetric parameters of LEDs. The most methods are intended for definition only one parameter (for example, luminous flux) or one characteristic (for example, the angular distribution of energy or the spectral characteristics). Besides, devices used these methods are intended for measuring parameters in only one point or plane. This problem can be solved by using a dome diagnostics system of optical parameters and characteristics of LEDs, developed by specialists of the department OEDS chair of ITMO University in Russia. The paper presents the theoretical aspects of the analysis of LED's spatial (angular), energy and color parameters by using mentioned of diagnostics system. The article also presents the results of spatial), energy and color parameters measurements of some LEDs brands.

  15. Developments of scintillator-based soft x-ray diagnostic in LHD with CsI:Tl and P47 scintillators.

    PubMed

    Bando, T; Ohdachi, S; Suzuki, Y

    2016-11-01

    Multi-channel soft x-ray (SX) diagnostic has been used in the large helical device (LHD) to research magnetohydrodynamic equilibria and activities. However, in the coming deuterium plasma experiments of LHD, it will be difficult to use semiconductor systems near LHD. Therefore, a new type of SX diagnostic, a scintillator-based type diagnostic, has been investigated in order to avoid damage from the radiation. A fiber optic plate coated by P47 scintillator will be used to detect SX emission. Scintillation light will be transferred by pure silica core optical fibers and detected by photomultiplier tubes. A vertically elongated section of LHD will be covered by a 13 ch. array. Effects from the Deuterium Deuterium neutrons can be negligible when the scintillator is covered by a Pb plate 4 cm in thickness to avoid gamma-rays.

  16. Developments of scintillator-based soft x-ray diagnostic in LHD with CsI:Tl and P47 scintillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bando, T., E-mail: bando.takahiro@nifs.ac.jp; Ohdachi, S.; Suzuki, Y.

    2016-11-15

    Multi-channel soft x-ray (SX) diagnostic has been used in the large helical device (LHD) to research magnetohydrodynamic equilibria and activities. However, in the coming deuterium plasma experiments of LHD, it will be difficult to use semiconductor systems near LHD. Therefore, a new type of SX diagnostic, a scintillator-based type diagnostic, has been investigated in order to avoid damage from the radiation. A fiber optic plate coated by P47 scintillator will be used to detect SX emission. Scintillation light will be transferred by pure silica core optical fibers and detected by photomultiplier tubes. A vertically elongated section of LHD will bemore » covered by a 13 ch. array. Effects from the Deuterium Deuterium neutrons can be negligible when the scintillator is covered by a Pb plate 4 cm in thickness to avoid gamma-rays.« less

  17. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartlein, Rick; Hampton, Nigel; Perkel, Josh

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach asmore » a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.« less

  18. Curcumin as fluorescent probe for directly monitoring in vitro uptake of curcumin combined paclitaxel loaded PLA-TPGS nanoparticles

    NASA Astrophysics Data System (ADS)

    Nguyen, Hoai Nam; Thu Ha, Phuong; Sao Nguyen, Anh; Nguyen, Dac Tu; Doan Do, Hai; Nguyen Thi, Quy; Nhung Hoang Thi, My

    2016-06-01

    Theranostics, which is the combination of both therapeutic and diagnostic capacities in one dose, is a promising tool for both clinical application and research. Although there are many chromophores available for optical imaging, their applications are limited due to the photobleaching property or intrinsic toxicity. Curcumin, a natural compound extracted from the rhizome of curcuma longa, is well known thanks to its bio-pharmaceutical activities and strong fluorescence as biocompatible probe for bio-imaging. In this study, we aimed to fabricate a system with dual functions: diagnostic and therapeutic, based on poly(lactide)-tocopheryl polyethylene glycol succinate (PLA-TPGS) micelles co-loaded curcumin (Cur) and paclitaxel (PTX). Two kinds of curcumin nanoparticle (NP) were fabricated and characterized by Fourier transform infrared spectroscopy, field emission scanning electron microscopy and dynamic light scattering methods. The cellular uptake and fluorescent activities of curcumin in these systems were also tested by bioassay studies, and were compared with paclitaxe-oregon. The results showed that (Cur + PTX)-PLA-TPGS NPs is a potential system for cancer theranostics.

  19. Anti-DNase I antibodies in systemic lupus erythematosus: diagnostic value and share in the enzyme inhibition.

    PubMed

    Trofimenko, A S; Gontar, I P; Zborovsky, A B; Paramonova, O V

    2016-04-01

    Diagnostic accuracy of anti-DNase I antibodies measurement in a differentiation between SLE and other autoimmune rheumatic diseases was evaluated. The share of anti-DNase I and actin in the DNase I activity decrease in SLE was established. Serum samples were obtained from 54 patients with verified SLE, 52 control patients with other autoimmune rheumatic diseases, and 44 healthy persons. Anti-DNase I concentrations were measured by ELISA. Free and actin inhibited DNase I activities were evaluated in the fresh serum samples. The appraisal of antibodies and actin effects on DNase I activity was made using multiple regression. Anti-DNase I antibodies were positive in 35 SLE and 8 control patients, without significant difference between the mean antibody concentrations. Sensitivity of this test was 64.81 %, and specificity-84.62 %. Mean free DNase I activity in SLE was somewhat lower than in the control group as a result of augmented frequency of extremely low enzyme activities. On the contrary, after the exclusion of the latter cases we have revealed elevated mean free DNase I activity in the other SLE patients comparing to the similar control subgroup. Unlike the controls, low serum DNase I activity in SLE arose not only from actin and antibody action, but also, in half of the cases, from unidentified factor, related to active SLE. The accuracy of the anti-DNase I antibodies measurement is approximate to the present reference standard of SLE diagnostics. We first demonstrated that neither antibodies nor actin caused DNase I activity decrease in SLE.

  20. A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST.

    PubMed

    Xiao, Shumei; Zang, Qing; Han, Xiaofeng; Wang, Tengfei; Yu, Jin; Zhao, Junyu

    2016-07-01

    Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

  1. Exploring the Connection Between Star Formation and AGN Activity in the Local Universe

    NASA Technical Reports Server (NTRS)

    LaMassa, Stephanie M.; Heckman. T. M.; Ptak, Andrew; Schiminovich, D.; O'Dowd, M.; Bertincourt, B.

    2012-01-01

    We study a combined sample of 264 star-forming, 51 composite, and 73 active galaxies using optical spectra from SDSS and mid-infrared (mid-IR) spectra from the Spitzer Infrared Spectrograph. We examine optical and mid-IR spectroscopic diagnostics that probe the amount of star formation and relative energetic con- tributions from star formation and an active galactic nucleus (AGN). Overall we find good agreement between optical and mid-IR diagnostics. Misclassifications of galaxies based on the SDSS spectra are rare despite the presence of dust obscuration. The luminosity of the [NeII] 12.8 micron emission-line is well correlated with the star formation rate (SFR) measured from the SDSS spectra, and this holds for the star forming, composite, and AGN-dominated systems. AGN show a clear excess of [NeIII] 15.6 micron emission relative to star forming and composite systems. We find good qualitative agreement between various parameters that probe the relative contributions of the AGN and star formation, including: the mid-IR spectral slope, the ratio of the [NeV] 14.3 micron to [NeII] micron 12.8 fluxes, the equivalent widths of the 7.7, 11.3, and 17 micron PAH features, and the optical "D" parameter which measures the distance a source lies from the locus of star forming galaxies in the optical BPT emission-line diagnostic diagram. We also consider the behavior of the three individual PAH features by examining how their flux ratios depend upon the degree of AGN-dominance. We find that the PAH 11.3 micron feature is significantly suppressed in the most AGN-dominated systems.

  2. Laboratory Response to Ebola - West Africa and United States.

    PubMed

    Sealy, Tara K; Erickson, Bobbie R; Taboy, Céline H; Ströher, Ute; Towner, Jonathan S; Andrews, Sharon E; Rose, Laura E; Weirich, Elizabeth; Lowe, Luis; Klena, John D; Spiropoulou, Christina F; Rayfield, Mark A; Bird, Brian H

    2016-07-08

    The 2014-2016 Ebola virus disease (Ebola) epidemic in West Africa highlighted the need to maintain organized laboratory systems or networks that can be effectively reorganized to implement new diagnostic strategies and laboratory services in response to large-scale events. Although previous Ebola outbreaks enabled establishment of critical laboratory practice safeguards and diagnostic procedures, this Ebola outbreak in West Africa highlighted the need for planning and preparedness activities that are better adapted to emerging pathogens or to pathogens that have attracted little commercial interest. The crisis underscored the need for better mechanisms to streamline development and evaluation of new diagnostic assays, transfer of material and specimens between countries and organizations, and improved processes for rapidly deploying health workers with specific laboratory expertise. The challenges and events of the outbreak forced laboratorians to examine not only the comprehensive capacities of existing national laboratory systems to recognize and respond to events, but also their sustainability over time and the mechanisms that need to be pre-established to ensure effective response. Critical to this assessment was the recognition of how response activities (i.e., infrastructure support, logistics, and workforce supplementation) can be used or repurposed to support the strengthening of national laboratory systems during the postevent transition to capacity building and recovery. This report compares CDC's domestic and international laboratory response engagements and lessons learned that can improve future responses in support of the International Health Regulations and Global Health Security Agenda initiatives.The activities summarized in this report would not have been possible without collaboration with many U.S. and international partners (http://www.cdc.gov/vhf/ebola/outbreaks/2014-west-africa/partners.html).

  3. Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.

    PubMed

    Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes

    2015-01-01

    this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.

  4. Embedding CLIPS in a database-oriented diagnostic system

    NASA Technical Reports Server (NTRS)

    Conway, Tim

    1990-01-01

    This paper describes the integration of C Language Production Systems (CLIPS) into a powerful portable maintenance aid (PMA) system used for flightline diagnostics. The current diagnostic target of the system is the Garrett GTCP85-180L, a gas turbine engine used as an Auxiliary Power Unit (APU) on some C-130 military transport aircraft. This project is a database oriented approach to a generic diagnostic system. CLIPS is used for 'many-to-many' pattern matching within the diagnostics process. Patterns are stored in database format, and CLIPS code is generated by a 'compilation' process on the database. Multiple CLIPS rule sets and working memories (in sequence) are supported and communication between the rule sets is achieved via the export and import commands. Work is continuing on using CLIPS in other portions of the diagnostic system and in re-implementing the diagnostic system in the Ada language.

  5. On-line experimental validation of a model-based diagnostic algorithm dedicated to a solid oxide fuel cell system

    NASA Astrophysics Data System (ADS)

    Polverino, Pierpaolo; Esposito, Angelo; Pianese, Cesare; Ludwig, Bastian; Iwanschitz, Boris; Mai, Andreas

    2016-02-01

    In the current energetic scenario, Solid Oxide Fuel Cells (SOFCs) exhibit appealing features which make them suitable for environmental-friendly power production, especially for stationary applications. An example is represented by micro-combined heat and power (μ-CHP) generation units based on SOFC stacks, which are able to produce electric and thermal power with high efficiency and low pollutant and greenhouse gases emissions. However, the main limitations to their diffusion into the mass market consist in high maintenance and production costs and short lifetime. To improve these aspects, the current research activity focuses on the development of robust and generalizable diagnostic techniques, aimed at detecting and isolating faults within the entire system (i.e. SOFC stack and balance of plant). Coupled with appropriate recovery strategies, diagnosis can prevent undesired system shutdowns during faulty conditions, with consequent lifetime increase and maintenance costs reduction. This paper deals with the on-line experimental validation of a model-based diagnostic algorithm applied to a pre-commercial SOFC system. The proposed algorithm exploits a Fault Signature Matrix based on a Fault Tree Analysis and improved through fault simulations. The algorithm is characterized on the considered system and it is validated by means of experimental induction of faulty states in controlled conditions.

  6. CAD-Based Shielding Analysis for ITER Port Diagnostics

    NASA Astrophysics Data System (ADS)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  7. Using Patient-Pathway Analysis to Inform a Differentiated Program Response to Tuberculosis: The Case of Kenya

    PubMed Central

    Masini, Enos; Hanson, Christy; Ogoro, Jeremiah; Brown, Jessie; Ngari, Faith; Mingkwan, Pia; Makayova, Julia; Osberg, Mike

    2017-01-01

    Abstract Background A recent tuberculosis prevalence survey in Kenya found that the country is home to nearly twice as many patients with tuberculosis as previously estimated. Kenya has prioritized identifying and treating the unnotified or missing cases of tuberculosis. This requires a better understanding of patient care seeking and system weaknesses. Methods A patient-pathway analysis (PPA) was completed to assess the alignment between patient care seeking and the availability of tuberculosis diagnostic and treatment services at the national level and for all 47 counties at the subnational level in Kenya. Results It was estimated that more than half of patients initiate care in the public sector. Nationally, just under half of patients encountered tuberculosis diagnostic and treatment capacity where they initiated care. Overall, there was distinct variation in diagnostic and treatment availability across counties and facility levels. Discussion The PPA results emphasized the need for a differentiated approach to tuberculosis care, by county, and the distinct need for better referral systems. The majority of Kenyans actively sought care; improving diagnostic and treatment capacity in the formal and informal private sector, as well as in the public sector, could help identify the majority of missing cases. PMID:29117349

  8. Helminth parasitic infections of the central nervous system: a diagnostic approach.

    PubMed

    Othman, Ahmad A; Bruschi, Fabrizio; Ganna, Ahmed A

    2014-04-01

    Helminth parasitic infections of the central nervous system (CNS) occur worldwide with high prevalence in tropical and subtropical countries. Clinical evaluation of patients is mandatory, and it is convenient to group the clinical manifestations into syndromes: for example space-occupying lesions, meningitis, and encephalitis. The history should focus on residence or travel to endemic areas, diet, activities, intercurrent medical conditions, and associated clinical clues. Direct parasitological diagnosis can be reached by cerebrospinal fluid and cerebral tissue examination either by microscopy, culture, or immunological techniques. Immunodiagnosis by detection of parasite antibodies or antigens in serum could provide indirect evidence of parasitic infections. In addition, various imaging and radiological techniques e.g., computed tomography (CT) scan and magnetic resonance imaging (MRI) complement the diagnostic work-up of CNS diseases. Finally, the helminthic CNS infections of global impact, such as schistosomiasis, neurotoxocariasis, Strongyloides infection, neurotrichinosis, neurocysticercosis, and echinococcosis will be briefly discussed as regards the principal clinical and diagnostic features.

  9. An Integrated Cardiology Patient Management System

    PubMed Central

    Kiely, F. Michael

    1988-01-01

    An integrated clinical database has been developed for all diagnostic cardiac services at Vancouver General Hospital. The system is installed on a Data General MV/10000 computer and utilizes the Flagship Application Generator from EPIC Systems Corp. Clinical information, as well as demographic and administrative data, is collected. The system features a custom menu for each user, whose selections provide direct access to the desired functional modules. The intention is to collect data from all the diagnostic areas of the Division of Cardiology, viz., Cardiac Ultrasound, Cardiac Catheterization Laboratory, Pacemaker Clinic and Electrocardiology (including 24 hour ambulatory EKGs and exercise testing). Automated links to the hospital's Admitting/Discharge/Transfer and Billing/Accounts Receivable systems have been implemented over the hospital's local area network. The system is used to produce routine reports of test results, patient billings, and departmental workload statistics. Inquiry functions permit the rapid location of patient records and produce an integrated profile of cardiology activity. In addition, selective searches of the data are available for research and/or other purposes.

  10. A diagnostic interface for the ICOsahedral Non-hydrostatic (ICON) modelling framework based on the Modular Earth Submodel System (MESSy v2.50)

    NASA Astrophysics Data System (ADS)

    Kern, Bastian; Jöckel, Patrick

    2016-10-01

    Numerical climate and weather models have advanced to finer scales, accompanied by large amounts of output data. The model systems hit the input and output (I/O) bottleneck of modern high-performance computing (HPC) systems. We aim to apply diagnostic methods online during the model simulation instead of applying them as a post-processing step to written output data, to reduce the amount of I/O. To include diagnostic tools into the model system, we implemented a standardised, easy-to-use interface based on the Modular Earth Submodel System (MESSy) into the ICOsahedral Non-hydrostatic (ICON) modelling framework. The integration of the diagnostic interface into the model system is briefly described. Furthermore, we present a prototype implementation of an advanced online diagnostic tool for the aggregation of model data onto a user-defined regular coarse grid. This diagnostic tool will be used to reduce the amount of model output in future simulations. Performance tests of the interface and of two different diagnostic tools show, that the interface itself introduces no overhead in form of additional runtime to the model system. The diagnostic tools, however, have significant impact on the model system's runtime. This overhead strongly depends on the characteristics and implementation of the diagnostic tool. A diagnostic tool with high inter-process communication introduces large overhead, whereas the additional runtime of a diagnostic tool without inter-process communication is low. We briefly describe our efforts to reduce the additional runtime from the diagnostic tools, and present a brief analysis of memory consumption. Future work will focus on optimisation of the memory footprint and the I/O operations of the diagnostic interface.

  11. Bruxism defined and graded: an international consensus.

    PubMed

    Lobbezoo, F; Ahlberg, J; Glaros, A G; Kato, T; Koyano, K; Lavigne, G J; de Leeuw, R; Manfredini, D; Svensson, P; Winocur, E

    2013-01-01

    To date, there is no consensus about the definition and diagnostic grading of bruxism. A written consensus discussion was held among an international group of bruxism experts as to formulate a definition of bruxism and to suggest a grading system for its operationalisation. The expert group defined bruxism as a repetitive jaw-muscle activity characterised by clenching or grinding of the teeth and/or by bracing or thrusting of the mandible. Bruxism has two distinct circadian manifestations: it can occur during sleep (indicated as sleep bruxism) or during wakefulness (indicated as awake bruxism). For the operationalisation of this definition, the expert group proposes a diagnostic grading system of 'possible', 'probable' and 'definite' sleep or awake bruxism. The proposed definition and grading system are suggested for clinical and research purposes in all relevant dental and medical domains. © 2012 Blackwell Publishing Ltd.

  12. [Redox-potential of blood and consistence of energoproviding defence system in cytomegalovirus infection in pregnancy].

    PubMed

    Dzhikiia, I V; Rizhvadze, M A; Dzhangidze, M A

    2006-05-01

    We have studied the relationship between the hypoxic change and mitochondrial redox-potential disturbances in the mechanism of pheto-placental insufficiency in pregnancy with cytomegalovirus infection (CMV), detected by the positive anti-CMV-IgG titer and more then 4-fold increase of low avid anti-CMV-IgG. It was shown, that chronic CMV infection induces production of active forms of oxygen, peroxidation of structures and concurrently damage of mitochondria with essential decrease of ATP level. Results of the study have shown the important diagnostic value of estimation of hypoxic-oxidative damage induced by CMV infection. The results also revealed important relationships between the activity of the CMV infection and intensity of mitochondrial damage. On the basis of our investigations we suggest the additional diagnostic test (the determination of citozol NADH dependent isocitratdehydrogenaze activity) to evaluate the depth of CMV induced metabolic disturbances.

  13. Initial operation of the NSTX-Upgrade real-time velocity diagnostic

    DOE PAGES

    Podestà, M.; Bell, R. E.

    2016-11-03

    A real-time velocity (RTV) diagnostic based on active charge-exchange recombination spectroscopy is now operational on the National Spherical Torus Experiment-Upgrade (NSTX-U) spherical torus (Menard et al 2012 Nucl. Fusion 52 083015). We designed the system in order to supply plasma velocity data in real time to the NSTX-U plasma control system, as required for the implementation of toroidal rotation control. Our measurements are available from four radii at a maximum sampling frequency of 5 kHz. Post-discharge analysis of RTV data provides additional information on ion temperature, toroidal velocity and density of carbon impurities. Furthermore, examples of physics studies enabled bymore » RTV measurements from initial operations of NSTX-U are discussed.« less

  14. [The functional state classification and evaluation of the stability level in mental loads based on the factor structure of heart rate variability parameters].

    PubMed

    Mashin, V A; Mashina, M N

    2004-12-01

    In the paper, outcomes of the researches devoted to factor analysis of heart rate variability parameters and definition of the most informative parameters for diagnostics of functional states and an evaluation of level of stability to mental loads, are presented. The factor structure of parameters, which unclude integral level of heart rate variability (1), balance between activity of vagus and brain cortical-limbic systems (2), integrated level of cardiovascular system functioning (3), is substantiated. Factor analysis outcomes have been used for construction of functional state classification, for their differential diagnostics, and for development and check of algorithm for evaluation of the stability level in mental loads.

  15. The role and diagnostic value of cell-free DNA in systemic lupus erythematosus.

    PubMed

    Truszewska, Anna; Foroncewicz, Bartosz; Pączek, Leszek

    2017-01-01

    Cell-free DNA (cfDNA) represents a small fraction of total DNA pool that circulates freely in the blood both in normal and pathological conditions. Data indicate that cfDNA plays an important role in the pathogenesis of systemic lupus erythematosus (SLE) and hypomethylation may be crucial for its immunogenic properties. Although differences in quantification methodology hinder the comparison of results between the studies, it appears that levels of cfDNA are abnormally elevated in SLE patients and correlate with various antibody titers, but not with disease activity. Increased cfDNA concentration, however, may be associated with active lupus nephritis. Most of the studies confirmed apoptosis as the major cfDNA release mechanism in various conditions, but formation of neutrophil extracellular traps may significantly contribute to the cfDNA generation in SLE patients. In this review, we summarise current knowledge about the role and possible origin of cfDNA in SLE patients, and discuss why cfDNA testing for diagnostic and prognosis of SLE remains questionable.

  16. Optimization of Antenna Current Feeding for the Alfvén Eigenmodes Active Diagnostic System of JET

    NASA Astrophysics Data System (ADS)

    Albarracin Manrique, Marcos A.; Ruchko, L.; Pires, C. J. A.; Galvão, R. M. O.; Elfimov, A. G.

    2018-04-01

    The possibility of exploring proper phasing of the feeding currents in the existing antenna of the Alfvén Eigenmodes Active Diagnostic system of JET, to excite pure toroidal spectra of Toroidal Alfvén Eigenmodes, is numerically investigated. Special attention is given to the actual perturbed fields excited in the plasma, which are calculated self-consistently using the antenna version of the CASTOR code. It is found that due to the close spacing of the JET antenna modules and quasi degeneracy of modes with medium to high values of the toroidal mode number n, although a proper choice of the phasing of the feeding currents of the antenna modules indeed leads to an increase of the perturbed fields of the selected mode, modes with nearby values of n are also excited with large amplitudes, so that a scheme to proper select the detected modes remains necessary. A scheme using different antenna position distribution is proposed to achieve successful optimization.

  17. How to Use the DX SYSTEM of Diagnostic Testing. Methodology Project.

    ERIC Educational Resources Information Center

    McArthur, David; Cabello, Beverly

    The DX SYSTEM of Diagnostic Testing is an easy-to-use computerized system for developing and administering diagnostic tests. A diagnostic test measures a student's mastery of a specific domain (skill or content area). It examines the necessary subskills hierarchically from the most to the least complex. The DX SYSTEM features tailored testing with…

  18. Efficient fault diagnosis of helicopter gearboxes

    NASA Technical Reports Server (NTRS)

    Chin, H.; Danai, K.; Lewicki, D. G.

    1993-01-01

    Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.

  19. Antibodies against C1q Are a Valuable Serological Marker for Identification of Systemic Lupus Erythematosus Patients with Active Lupus Nephritis

    PubMed Central

    Chi, Shuhong; Yu, Yunxia; Shi, Juan; Zhang, Yurong; Yang, Jijuan; Yang, Lijuan; Liu, Xiaoming

    2015-01-01

    Objective. An early diagnosis of lupus nephritis (LN) has an important clinical implication in guiding treatments of systemic lupus erythematosus (SLE) in clinical settings. In this study, the diagnostic values of circulating autoantibodies to C1q alone or in combination with other markers for accessing active SLE and LN were evaluated. Methods. The diagnostic value of anti-C1q autoantibodies for identification of patients with active SLE disease and LN was evaluated by analyzing the level of anti-C1q antibodies in sera from 95 SLE patients, 40 non-SLE patients, and 34 healthy cohorts. Results. The prevalence of anti-C1q antibodies was significantly higher in patients with SLE (50/95, 52.6%), active SLE (40/51, 78.4%), and LN (30/35, 85.7%) in comparison with non-SLE patient controls, patients with inactive SLE, and non-LN, respectively. A combination of anti-C1q with anti-dsDNA and/or levels of complements C3 and C4 exhibited an increased specificity but a decreased sensitivity for identification of patients with active SLE and LN diseases relative to each of these markers alone. Conclusion. Anti-C1q antibodies were strongly associated with disease activity and LN in SLE patients, suggesting that it may be a reliable serological marker for identification of SLE patients with active LN and active SLE disease. PMID:26549923

  20. Measures to Improve Diagnostic Safety in Clinical Practice.

    PubMed

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-10-20

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of "diagnostic safety" related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health-care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  1. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  2. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  3. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  4. Specialist integrated haematological malignancy diagnostic services: an Activity Based Cost (ABC) analysis of a networked laboratory service model.

    PubMed

    Dalley, C; Basarir, H; Wright, J G; Fernando, M; Pearson, D; Ward, S E; Thokula, P; Krishnankutty, A; Wilson, G; Dalton, A; Talley, P; Barnett, D; Hughes, D; Porter, N R; Reilly, J T; Snowden, J A

    2015-04-01

    Specialist Integrated Haematological Malignancy Diagnostic Services (SIHMDS) were introduced as a standard of care within the UK National Health Service to reduce diagnostic error and improve clinical outcomes. Two broad models of service delivery have become established: 'co-located' services operating from a single-site and 'networked' services, with geographically separated laboratories linked by common management and information systems. Detailed systematic cost analysis has never been published on any established SIHMDS model. We used Activity Based Costing (ABC) to construct a cost model for our regional 'networked' SIHMDS covering a two-million population based on activity in 2011. Overall estimated annual running costs were £1 056 260 per annum (£733 400 excluding consultant costs), with individual running costs for diagnosis, staging, disease monitoring and end of treatment assessment components of £723 138, £55 302, £184 152 and £94 134 per annum, respectively. The cost distribution by department was 28.5% for haematology, 29.5% for histopathology and 42% for genetics laboratories. Costs of the diagnostic pathways varied considerably; pathways for myelodysplastic syndromes and lymphoma were the most expensive and the pathways for essential thrombocythaemia and polycythaemia vera being the least. ABC analysis enables estimation of running costs of a SIHMDS model comprised of 'networked' laboratories. Similar cost analyses for other SIHMDS models covering varying populations are warranted to optimise quality and cost-effectiveness in delivery of modern haemato-oncology diagnostic services in the UK as well as internationally. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. DDS: The Dental Diagnostic Simulation System.

    ERIC Educational Resources Information Center

    Tira, Daniel E.

    The Dental Diagnostic Simulation (DDS) System provides an alternative to simulation systems which represent diagnostic case studies of relatively limited scope. It may be used to generate simulated case studies in all of the dental specialty areas with case materials progressing through the gamut of the diagnostic process. The generation of a…

  6. A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Shumei; Zang, Qing, E-mail: zangq@ipp.ac.cn; Han, Xiaofeng

    Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump systemmore » can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.« less

  7. Tracking Progress in Improving Diagnosis: A Framework for Defining Undesirable Diagnostic Events.

    PubMed

    Olson, Andrew P J; Graber, Mark L; Singh, Hardeep

    2018-01-29

    Diagnostic error is a prevalent, harmful, and costly phenomenon. Multiple national health care and governmental organizations have recently identified the need to improve diagnostic safety as a high priority. A major barrier, however, is the lack of standardized, reliable methods for measuring diagnostic safety. Given the absence of reliable and valid measures for diagnostic errors, we need methods to help establish some type of baseline diagnostic performance across health systems, as well as to enable researchers and health systems to determine the impact of interventions for improving the diagnostic process. Multiple approaches have been suggested but none widely adopted. We propose a new framework for identifying "undesirable diagnostic events" (UDEs) that health systems, professional organizations, and researchers could further define and develop to enable standardized measurement and reporting related to diagnostic safety. We propose an outline for UDEs that identifies both conditions prone to diagnostic error and the contexts of care in which these errors are likely to occur. Refinement and adoption of this framework across health systems can facilitate standardized measurement and reporting of diagnostic safety.

  8. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    NASA Astrophysics Data System (ADS)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-09-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution.

  9. Electric Field-Mediated Processing of Biomaterials: Toward Nanostructured Biomimetic Systems. Appendix 3

    NASA Technical Reports Server (NTRS)

    Bowlin, Gary L.; Simpson, David G.; Lam, Philippe; Wnek, Gary E.

    2001-01-01

    Significant opportunities exist for the processing of synthetic and biological polymers using electric fields ('electroprocessing'). We review casting of multi-component films and the spinning of fibers in electric fields, and indicate opportunities for the creation of smart polymer systems using these approaches. Applications include 2-D substrates for cell growth and diagnostics, scaffolds for tissue engineering and repair, and electromechanically active biosystems.

  10. Systematic Benchmarking of Diagnostic Technologies for an Electrical Power System

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Jensen, David; Poll, Scott

    2009-01-01

    Automated health management is a critical functionality for complex aerospace systems. A wide variety of diagnostic algorithms have been developed to address this technical challenge. Unfortunately, the lack of support to perform large-scale V&V (verification and validation) of diagnostic technologies continues to create barriers to effective development and deployment of such algorithms for aerospace vehicles. In this paper, we describe a formal framework developed for benchmarking of diagnostic technologies. The diagnosed system is the Advanced Diagnostics and Prognostics Testbed (ADAPT), a real-world electrical power system (EPS), developed and maintained at the NASA Ames Research Center. The benchmarking approach provides a systematic, empirical basis to the testing of diagnostic software and is used to provide performance assessment for different diagnostic algorithms.

  11. Active and Passive Diagnostic Signatures of Special Nuclear Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, William L.; Karpius, Peter Joseph; Myers, Steven Charles

    2017-05-26

    An overview will be given discussing signatures associated with special nuclear materials acquired using both active and passive diagnostic techniques. Examples of how technology advancements have helped improve diagnostic capabilities to meet the challenges of today’s applications will be discussed.

  12. Humidity control of an incubator using the microcontroller-based active humidifier system employing an ultrasonic nebulizer.

    PubMed

    Güler, I; Burunkaya, M

    2002-01-01

    Relative humidity levels of an incubator were measured and controlled. An ultrasonic nebulizer system as an active humidifier was used to humidify the incubator environment. An integrated circuit-type humidity sensor was used to measure the humidity level of the incubator environment. Measurement and control processes were achieved by a PIC microcontroller. The high-performance and high-speed PIC provided the flexibility of the system. The developed system can be used effectively for the intensive care of newborns and/or premature babies. Since the humidifier generates an aerosol in ambient conditions, it is possible to provide the high relative humidity level for therapeutic and diagnostic purposes in medicine.

  13. CHANGING OUR DIAGNOSTIC PARADIGM: MOVEMENT SYSTEM DIAGNOSTIC CLASSIFICATION

    PubMed Central

    Kamonseki, Danilo H.; Staker, Justin L.; Lawrence, Rebekah L.; Braman, Jonathan P.

    2017-01-01

    Proper diagnosis is a first step in applying best available treatments, and prognosticating outcomes for clients. Currently, the majority of musculoskeletal diagnoses are classified according to pathoanatomy. However, the majority of physical therapy treatments are applied toward movement system impairments or pain. While advocated within the physical therapy profession for over thirty years, diagnostic classification within a movement system framework has not been uniformly developed or adopted. We propose a basic framework and rationale for application of a movement system diagnostic classification for atraumatic shoulder pain conditions, as a case for the broader development of movement system diagnostic labels. Shifting our diagnostic paradigm has potential to enhance communication, improve educational efficiency, facilitate research, directly link to function, improve clinical care, and accelerate preventive interventions. PMID:29158950

  14. Further Investigations of Ionospheric Total Electron Content and Scintillation Effects on Transionospheric Radiowave Propagation

    DTIC Science & Technology

    1998-02-12

    HAARP ). 14. SUBJECT TERMS Global Positioning System (GPS), High Frequency Active Auroral Research Program ( HAARP ), ionosphere, radiowave...Scintillation Simulation 23 4.10 Automated Calibrations 23 5. HAARP Activities 24 5.1 Development of HAARP Diagnostics 24 5.2 Facilitation of... HAARP Operations and Broader Scientific Collaborations 27 5.3 Public Relations 28 6. Publications 30 References 30 Acronyms and Initials 30 Appendix

  15. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... irradiation. Diagnostic source assembly means the tube housing assembly with a beam-limiting device attached. Diagnostic x-ray system means an x-ray system designed for irradiation of any part of the human body for the... diagnostic source assembly. Fluoroscopic irradiation time means the cumulative duration during an examination...

  16. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... irradiation. Diagnostic source assembly means the tube housing assembly with a beam-limiting device attached. Diagnostic x-ray system means an x-ray system designed for irradiation of any part of the human body for the... diagnostic source assembly. Fluoroscopic irradiation time means the cumulative duration during an examination...

  17. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... irradiation. Diagnostic source assembly means the tube housing assembly with a beam-limiting device attached. Diagnostic x-ray system means an x-ray system designed for irradiation of any part of the human body for the... diagnostic source assembly. Fluoroscopic irradiation time means the cumulative duration during an examination...

  18. Transmission research activities at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Lewicki, D. G.

    1990-01-01

    A joint research program, to advance the technology of rotorcraft transmissions, consists of analytical and experimental efforts to achieve the overall goals of reducing transmission weight and noise, while increasing life and reliability. Recent activities in the areas of transmission and related component research are highlighted. Current areas include specific technologies in support of military rotary wing aviation, gearing technology, transmission noise reduction studies, a recent interest in gearbox diagnostics, and advanced transmission system studies. Results of recent activities are presented along with near term research plans.

  19. Characterizing the stellar population of a sample of star forming galaxies with high emission of both [OIV]25.9um and [NeII]12.8um

    NASA Astrophysics Data System (ADS)

    Martínez-Paredes, M.; Bruzual, G.; Meléndez, M.; González-Martín, O.

    2017-11-01

    The optical diagnostic diagram te{BPT81, VO87} allow us to discriminate between the different excitation mechanism, like that produce by young stars and that produce by the AGN during the accretion of matter onto the super massive black hole. This kind of tool are important because allow us to study the connection between starburst and AGN. However, despite the great success, the identification of the most heavily dust-obscured systems remains a challenge for optical diagrams. Mid-infrared diagnostic are more suitable to study dust-enshrouded systems, where the effect of dust obscuration can hamper the interpretation of traditional optical diagnostics, since in this spectral range we have access to low-ionization lines (as [Ne II]12.8μm) typical of star forming regions and high ionization lines typical of active galaxies ([OIV]25.9μm), while intermediate ionization-lines ([Ne III]15.3μm) provide a unique scenario where the AGN coexist with active star formation in the host galaxy. In a previous work te{Melendez14} we have carried out extensive and detailed photoionization modeling to successfully separate the different excitation mechanism in the mid-infrared diagnostic diagrams proposed by te{Weaver10}. We successfully modelled the AGN and starburst galaxies ratios lines of [NeIII]/[NeII] Vs [OIV]/[NeIII]. However, we failed in modelling the observed ratio lines in galaxies with a normal star formation activity ([NeIII]/[NeII]<1 and [OIV]/[NeIII]<1). These results suggest the presence of a more complex excitation mechanism in these galaxies. In this project we are using the update stellar population models from te{BC17} that include massive stars, and the update photoionization models from CLOUDY from te{Ferland17}, to characterize the properties of the stellar population that produce the high ionization conditions in these galaxies.

  20. [Cognitive errors in diagnostic decision making].

    PubMed

    Gäbler, Martin

    2017-10-01

    Approximately 10-15% of our diagnostic decisions are faulty and may lead to unfavorable and dangerous outcomes, which could be avoided. These diagnostic errors are mainly caused by cognitive biases in the diagnostic reasoning process.Our medical diagnostic decision-making is based on intuitive "System 1" and analytical "System 2" diagnostic decision-making and can be deviated by unconscious cognitive biases.These deviations can be positively influenced on a systemic and an individual level. For the individual, metacognition (internal withdrawal from the decision-making process) and debiasing strategies, such as verification, falsification and rule out worst-case scenarios, can lead to improved diagnostic decisions making.

  1. Oak Ridge Reservation Public Warning Siren System Annual Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. F. Gee

    2000-10-01

    The full operational test of the Oak Ridge Reservation (ORR) Public Warning Siren System (PWSS) was successfully conducted on September 27, 2000. The annual test is a full-scale sounding of the individual siren systems around each of the three Department of Energy (DOE) sites in Oak Ridge, Tennessee. The purpose of the annual test is to demonstrate and validate the siren systems' ability to alert personnel outdoors in the Immediate Notification Zones (INZ) (approximately two miles) around each site. The success of this test is based on two critical functions of the siren system. The first function is system operability.more » The system is considered operable if 90% of the sirens are operational. System diagnostics and direct field observations were used to validate the operability of the siren systems. Based on the diagnostic results and field observations, greater than 90% of the sirens were considered operational. The second function is system audibility. The system is considered audible if the siren could be heard in the immediate notification zones around each of the three sites. Direct field observations, along with sound level measurements, were used to validate the audibility of the siren system. Based on the direct field observations and sound level measurements, the siren system was considered audible. The combination of field observations, system diagnostic status reports, and sound level measurements provided a high level of confidence that the system met and would meet operational requirements upon demand. As part of the overall system test, the Tennessee Emergency Management Agency (TEMA) activated the Emergency Alerting System (EAS), which utilized area radio stations to make announcements regarding the test and to remind residents of what to do in the event of an actual emergency.« less

  2. [Improvement of higher medical education via the system of quality specialist training].

    PubMed

    Artiukhov, I P; Samotesov, P A; Nikulina, S Iu; Salmina, A B; Petrova, M M; Gritsan, A I; Rossiev, D A

    2009-01-01

    Development of the system of management of quality specialist training in the Kraysnoysrsk State Medical Academy allowed to optimize administration and academic process, create conditions for introduction of innovative technologies in educational, research, and clinico-diagnostic activities for the purpose of their standardization and realization of managerial decisions. The new system promotes organization of administrative and educational work of the Academy in line with leading trends of regional development, stimulates creativity and strategic planning.

  3. SERS diagnostic platforms, methods and systems microarrays, biosensors and biochips

    DOEpatents

    Vo-Dinh, Tuan [Knoxville, TN

    2007-09-11

    A Raman integrated sensor system for the detection of targets including biotargets includes at least one sampling platform, at least one receptor probe disposed on the sampling platform, and an integrated circuit detector system communicably connected to the receptor. The sampling platform is preferably a Raman active surface-enhanced scattering (SERS) platform, wherein the Raman sensor is a SERS sensor. The receptors can include at least one protein receptor and at least one nucleic acid receptor.

  4. Regulatory perspectives and research activities at the FDA on the use of phantoms with in vivo diagnostic devices

    NASA Astrophysics Data System (ADS)

    Agrawal, Anant; Gavrielides, Marios A.; Weininger, Sandy; Chakrabarti, Kish; Pfefer, Joshua

    2008-02-01

    For a number of years, phantoms have been used to optimize device parameters and validate performance in the primary medical imaging modalities (CT, MRI, PET/SPECT, ultrasound). Furthermore, the FDA under the Mammography Quality Standards Act (MQSA) requires image quality evaluation of mammography systems using FDA-approved phantoms. The oldest quantitative optical diagnostic technology, pulse oximetry, also benefits from the use of active phantoms known as patient simulators to validate certain performance characteristics under different clinically-relevant conditions. As such, guidance provided by the FDA to its staff and to industry on the contents of pre-market notification and approval submissions includes suggestions on how to incorporate the appropriate phantoms in establishing device effectiveness. Research at the FDA supports regulatory statements on the use of phantoms by investigating how phantoms can be designed, characterized, and utilized to determine critical device performance characteristics. These examples provide a model for how novel techniques in the rapidly growing field of optical diagnostics can use phantoms during pre- and post-market regulatory testing.

  5. Heart Rate Variability – a Tool to Differentiate Positive and Negative Affective States in Pigs?

    USDA-ARS?s Scientific Manuscript database

    The causal neurophysiological processes, such as autonomic nervous system activity, that mediate behavioral and physiological reactivity to an environment have largely been ignored. Heart rate variability (HRV) analysis is a clinical diagnostic tool used to assess affective states (stressful and ple...

  6. Diagnosis and Classification in Autism.

    ERIC Educational Resources Information Center

    Waterhouse, Lynn; And Others

    1996-01-01

    This study compared four systems for diagnosis of autism (Diagnostic and Statistical Manuals of Mental Disorders III, III-R, and IV, and the International Classification of Disabilities-10) with 2 empirically derived taxa and 3 social subgroups (aloof, passive, and active but odd) in 194 preschool children with social impairment. Findings support…

  7. NASBA: A detection and amplification system uniquely suited for RNA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sooknanan, R.; Malek, L.T.

    1995-06-01

    The invention of PCR (polymerase chain reaction) has revolutionized our ability to amplify and manipulate a nucleic acid sequence in vitro. The commercial rewards of this revolution have driven the development of other nuclei acid amplification and detection methodologies. This has created an alphabet soup of technologies that use different amplification methods, including NASBA (nucleic acid sequence-based amplification), LCR (ligase chain reaction), SDA (strand displacement amplification), QBR (Q-beta replicase), CPR (cycling probe reaction), and bDNA (branched DNA). Despite the differences in their processes, these amplification systems can be separated into two broad categories based on how they achieve their goal:more » sequence-based amplification systems, such as PCR, NASBA, and SDA, amplify a target nucleic acid sequence. Signal-based amplification systems, such as LCR, QBR, CPR and bDNA, amplify or alter a signal from a detection reaction that is target-dependent. While the various methods have relative strengths and weaknesses, only NASBA offers the unique ability to homogeneously amplify an RNA analyte in the presence of homologous genomic DNA under isothermal conditions. Since the detection of RNA sequences almost invariably measures biological activity, it is an excellent prognostic indicator of activities as diverse as virus production, gene expression, and cell viability. The isothermal nature of the reaction makes NASBA especially suitable for large-scale manual screening. These features extend NASBA`s application range from research to commercial diagnostic applications. Field test kits are presently under development for human diagnostics as well as the burgeoning fields of food and environmental diagnostic testing. These developments suggest future integration of NASBA into robotic workstations for high-throughput screening as well. 17 refs., 1 tab.« less

  8. Multi-method automated diagnostics of rotating machines

    NASA Astrophysics Data System (ADS)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  9. Resilient actions in the diagnostic process and system performance.

    PubMed

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  10. A NEW HEALTH TECHNOLOGY ASSESSMENT SYSTEM FOR DEVICES: THE FIRST FIVE YEARS.

    PubMed

    Campbell, Bruce; Dobson, Lee; Higgins, Joanne; Dillon, Bernice; Marlow, Mirella; Pomfrett, Chris

    2017-01-01

    The aim of this study was to review 5 years of activity from a new system devised by the National Institute for Health and Care Excellence (NICE), for assessing medical devices and diagnostics aimed at identifying and speeding adoption of technologies with clinical and cost advantages, compared with current practice in the United Kingdom healthcare system. All eligible notified technologies were classified using the Food and Drug Administration and Global Medical Device Nomenclature nomenclatures. Decisions about selecting technologies for full assessment to produce NICE recommendations were reviewed, along with the reasons given to companies for not selecting products. Between 2009 and 2014, 186 technologies were notified (46 percent therapeutic and 54 percent diagnostic). Thirty-nine were judged ineligible (no regulatory approval), and 147 were considered by an independent committee. Of these, eighty (54 percent) were not selected for full assessment, most commonly because of insufficient evidence (86 percent): there were uncertainties specifically about benefits to the health service (54 percent), to patients (39 percent), and about cost (24 percent). The remaining 67 were selected and assessed for Medical Technology guidance (52 percent) (noninferior and/or lower cost consequences than current practice), for Diagnostics guidance (43 percent) or other NICE recommendations about adoption and use. Classifying technologies by two different systems showed no selection bias for any technology type or disease area. Identifying new or under-used devices and diagnostics with potential benefits and promoting their adoption is important to health services in the United Kingdom and worldwide. This new system offers a means of fostering both uptake and further research. Lack of research data on new products is a major obstacle to evaluation.

  11. Diagnostic value underlies asymmetric updating of impressions in the morality and ability domains.

    PubMed

    Mende-Siedlecki, Peter; Baron, Sean G; Todorov, Alexander

    2013-12-11

    While positive behavioral information is diagnostic when evaluating a person's abilities, negative information is diagnostic when evaluating morality. Although social psychology has considered these two domains as orthogonal and distinct from one another, we demonstrate that this asymmetry in diagnosticity can be explained by a single parsimonious principle--the perceived frequency of behaviors in these domains. Less frequent behaviors (e.g., high ability and low morality) are weighed more heavily in evaluations. We show that this statistical principle of frequency-derived diagnosticity is evident in human participants at both behavioral and neural levels of analysis. Specifically, activity in right ventrolateral prefrontal cortex increased preferentially when participants updated impressions based on diagnostic behaviors, and further, activity in this region covaried parametrically with the perceived frequency of behaviors. Activity in left ventrolateral PFC, left inferior frontal gyrus, and left superior temporal sulcus showed similar patterns of diagnosticity and sensitivity, though additional analyses confirmed that these regions responded primarily to updates based on immoral behaviors.

  12. A recoverable gas-cell diagnostic for the National Ignition Facility.

    PubMed

    Ratkiewicz, A; Berzak Hopkins, L; Bleuel, D L; Bernstein, L A; van Bibber, K; Cassata, W S; Goldblum, B L; Siem, S; Velsko, C A; Wiedeking, M; Yeamans, C B

    2016-11-01

    The high-fluence neutron spectrum produced by the National Ignition Facility (NIF) provides an opportunity to measure the activation of materials by fast-spectrum neutrons. A new large-volume gas-cell diagnostic has been designed and qualified to measure the activation of gaseous substances at the NIF. This in-chamber diagnostic is recoverable, reusable and has been successfully fielded. Data from the qualification of the diagnostic have been used to benchmark an Monte Carlo N-Particle Transport Code simulation describing the downscattered neutron spectrum seen by the gas cell. We present early results from the use of this diagnostic to measure the activation of nat Xe and discuss future work to study the strength of interactions between plasma and nuclei.

  13. Using Patient-Pathway Analysis to Inform a Differentiated Program Response to Tuberculosis: The Case of Kenya.

    PubMed

    Masini, Enos; Hanson, Christy; Ogoro, Jeremiah; Brown, Jessie; Ngari, Faith; Mingkwan, Pia; Makayova, Julia; Osberg, Mike

    2017-11-06

    A recent tuberculosis prevalence survey in Kenya found that the country is home to nearly twice as many patients with tuberculosis as previously estimated. Kenya has prioritized identifying and treating the unnotified or missing cases of tuberculosis. This requires a better understanding of patient care seeking and system weaknesses. A patient-pathway analysis (PPA) was completed to assess the alignment between patient care seeking and the availability of tuberculosis diagnostic and treatment services at the national level and for all 47 counties at the subnational level in Kenya. It was estimated that more than half of patients initiate care in the public sector. Nationally, just under half of patients encountered tuberculosis diagnostic and treatment capacity where they initiated care. Overall, there was distinct variation in diagnostic and treatment availability across counties and facility levels. The PPA results emphasized the need for a differentiated approach to tuberculosis care, by county, and the distinct need for better referral systems. The majority of Kenyans actively sought care; improving diagnostic and treatment capacity in the formal and informal private sector, as well as in the public sector, could help identify the majority of missing cases. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  14. Secular Trends in Pupils' Assessments of Physical Education Lessons in Regard to Their Self-Perception of Physical Fitness across the Educational Systems of Czech Republic and Poland

    ERIC Educational Resources Information Center

    Frömel, Karel; Vašícková, Jana; Svozil, Zbynek; Chmelík, František; Skalik, Krzysztof; Groffik, Dorota

    2014-01-01

    Observation of trends in physical education plays an integral role in motor-development diagnostics and in encouraging physical activity and a healthy lifestyle. This study aims to elucidate the current state of and trends in pupils' assessments of physical education lessons (PELs) in different education systems in the context of self-perception…

  15. Using the brain's fight-or-flight response for predicting mental illness on the human space flight program

    NASA Astrophysics Data System (ADS)

    Losik, L.

    A predictive medicine program allows disease and illness including mental illness to be predicted using tools created to identify the presence of accelerated aging (a.k.a. disease) in electrical and mechanical equipment. When illness and disease can be predicted, actions can be taken so that the illness and disease can be prevented and eliminated. A predictive medicine program uses the same tools and practices from a prognostic and health management program to process biological and engineering diagnostic data provided in analog telemetry during prelaunch readiness and space exploration missions. The biological and engineering diagnostic data necessary to predict illness and disease is collected from the pre-launch spaceflight readiness activities and during space flight for the ground crew to perform a prognostic analysis on the results from a diagnostic analysis. The diagnostic, biological data provided in telemetry is converted to prognostic (predictive) data using the predictive algorithms. Predictive algorithms demodulate telemetry behavior. They illustrate the presence of accelerated aging/disease in normal appearing systems that function normally. Mental illness can predicted using biological diagnostic measurements provided in CCSDS telemetry from a spacecraft such as the ISS or from a manned spacecraft in deep space. The measurements used to predict mental illness include biological and engineering data from an astronaut's circadian and ultranian rhythms. This data originates deep in the brain that is also damaged from the long-term exposure to cortisol and adrenaline anytime the body's fight or flight response is activated. This paper defines the brain's FOFR; the diagnostic, biological and engineering measurements needed to predict mental illness, identifies the predictive algorithms necessary to process the behavior in CCSDS analog telemetry to predict and thus prevent mental illness from occurring on human spaceflight missions.

  16. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isa, Nor Ashidi Mat

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability ofmore » the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.« less

  17. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    NASA Astrophysics Data System (ADS)

    Isa, Nor Ashidi Mat

    2015-05-01

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.

  18. Radiation effects in IFMIF Li target diagnostic systems

    NASA Astrophysics Data System (ADS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-04-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  19. The Risk of Mental Health Disorders Among U.S. Military Personnel Infected with Human Immunodeficiency Virus, Active Component, U.S. Armed Forces, 2000-2011

    DTIC Science & Technology

    2012-05-01

    Defense Medical Surveillance System (DMSS). An incident case of HSV2 was defi ned as two or more medical encounters with a diagnosis of “ genital ... herpes ” (ICD-9-CM 054.1 with any fi ft h digit) in any diagnostic position. Incidence rates of MHD were com- pared between three groups of active com

  20. A tri-fold hybrid classification approach for diagnostics with unexampled faulty states

    NASA Astrophysics Data System (ADS)

    Tamilselvan, Prasanna; Wang, Pingfeng

    2015-01-01

    System health diagnostics provides diversified benefits such as improved safety, improved reliability and reduced costs for the operation and maintenance of engineered systems. Successful health diagnostics requires the knowledge of system failures. However, with an increasing system complexity, it is extraordinarily difficult to have a well-tested system so that all potential faulty states can be realized and studied at product testing stage. Thus, real time health diagnostics requires automatic detection of unexampled system faulty states based upon sensory data to avoid sudden catastrophic system failures. This paper presents a trifold hybrid classification (THC) approach for structural health diagnosis with unexampled health states (UHS), which comprises of preliminary UHS identification using a new thresholded Mahalanobis distance (TMD) classifier, UHS diagnostics using a two-class support vector machine (SVM) classifier, and exampled health states diagnostics using a multi-class SVM classifier. The proposed THC approach, which takes the advantages of both TMD and SVM-based classification techniques, is able to identify and isolate the unexampled faulty states through interactively detecting the deviation of sensory data from the exampled health states and forming new ones autonomously. The proposed THC approach is further extended to a generic framework for health diagnostics problems with unexampled faulty states and demonstrated with health diagnostics case studies for power transformers and rolling bearings.

  1. Vacuum system design and tritium inventory for the TFTR charge exchange diagnostic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medley, S.S.

    The charge exchange diagnostic for the TFTR is comprised of two analyzer systems which contain a total of twenty independent mass/energy analyzers and one diagnostic neutral beam tentatively rated at 80 keV, 15 A. The associated vacuum systems were analyzed using the Vacuum System Transient Simulator (VSTS) computer program which models the transient transport of multi-gas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced cost, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and ofmore » the diagnostic working gases to the torus.« less

  2. Air Breathing Propulsion Controls and Diagnostics Research at NASA Glenn Under NASA Aeronautics Research Mission Programs

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2014-01-01

    This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

  3. An architecture for the development of real-time fault diagnosis systems using model-based reasoning

    NASA Technical Reports Server (NTRS)

    Hall, Gardiner A.; Schuetzle, James; Lavallee, David; Gupta, Uday

    1992-01-01

    Presented here is an architecture for implementing real-time telemetry based diagnostic systems using model-based reasoning. First, we describe Paragon, a knowledge acquisition tool for offline entry and validation of physical system models. Paragon provides domain experts with a structured editing capability to capture the physical component's structure, behavior, and causal relationships. We next describe the architecture of the run time diagnostic system. The diagnostic system, written entirely in Ada, uses the behavioral model developed offline by Paragon to simulate expected component states as reflected in the telemetry stream. The diagnostic algorithm traces causal relationships contained within the model to isolate system faults. Since the diagnostic process relies exclusively on the behavioral model and is implemented without the use of heuristic rules, it can be used to isolate unpredicted faults in a wide variety of systems. Finally, we discuss the implementation of a prototype system constructed using this technique for diagnosing faults in a science instrument. The prototype demonstrates the use of model-based reasoning to develop maintainable systems with greater diagnostic capabilities at a lower cost.

  4. Resilient Actions in the Diagnostic Process and System Performance

    PubMed Central

    Smith, Michael W.; Giardina, Traber Davis; Murphy, Daniel R.; Laxmisan, Archana; Singh, Hardeep

    2013-01-01

    Objectives Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by ‘resilient’ actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. Methods We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analyzed to identify barriers for rapid diagnostic evaluation, and PCPs’ actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Results Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Discussion Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs’ actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of ‘downstream’ measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety. PMID:23813210

  5. The INTELSAT VI SSTDMA network diagnostic system

    NASA Astrophysics Data System (ADS)

    Tamboli, Satish P.; Zhu, Xiaobo; Wilkins, Kim N.; Gupta, Ramesh K.

    The system-level design of an expert-system-based, near-real-time diagnostic system for INTELSAT VI satellite-switched time-division multiple access (SSTDMA) network is described. The challenges of INTELSAT VI diagnostics are discussed, along with alternative approaches for network diagnostics and the rationale for choosing a method based on burst unique-word detection. The focal point of the diagnostic system is the diagnostic processor, which resides in the central control and monitoring facility known as the INTELSAT Operations Center TDMA Facility (IOCTF). As real-time information such as burst unique-word detection data, reference terminal status data, and satellite telemetry alarm data are received at the IOCTF, the diagnostic processor continuously monitors the data streams. When a burst status change is detected, a 'snapshot' of the real-time data is forwarded to the expert system. Receipt of the change causes a set of rules to be invoked which associate the traffic pattern with a set of probable causes. A user-friendly interface allows a graphical view of the burst time plan and provides the ability to browse through the knowledge bases.

  6. Roles of laboratories and laboratory systems in effective tuberculosis programmes.

    PubMed

    Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul

    2007-05-01

    Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.

  7. A New Four-Barrel Pellet Injection System for the TJ-II Stellarator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Combs, Stephen Kirk; Foust, Charles R; McGill, James M

    2011-01-01

    A new pellet injection system for the TJ-II stellarator has been developed/constructed as part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Centro de Investigaciones Energ ticas, Medioambientales y Tecnol gicas (CIEMAT). ORNL is providing most of the injector hardware and instrumentation, the pellet diagnostics, and the pellet transport tubes; CIEMAT is responsible for the injector stand/interface to the stellarator, cryogenic refrigerator, vacuum pumps/ballast volumes, gas manifolds, remote operations, plasma diagnostics, and data acquisition. The pellet injector design is an upgraded version of that used for the ORNL injector installed on the Madison Symmetric Torus (MST).more » It is a four-barrel system equipped with a cryogenic refrigerator for in situ hydrogen pellet formation and a combined mechanical punch/propellant valve system for pellet acceleration (speeds ~100 to 1000 m/s). On TJ-II, it will be used as an active diagnostic and for fueling. To accommodate the plasma experiments planned for TJ-II, pellet sizes significantly smaller than those typically used for the MST application are required. The system will initially be equipped with four different pellet sizes, with the gun barrel bores ranging between ~0.5 to 1.0 mm. The new system is almost complete and is described briefly here, highlighting the new features added since the original MST injector was constructed. Also, the future installation on TJ-II is reviewed.« less

  8. Using hypermedia to develop an intelligent tutorial/diagnostic system for the Space Shuttle Main Engine Controller Lab

    NASA Technical Reports Server (NTRS)

    Oreilly, Daniel; Williams, Robert; Yarborough, Kevin

    1988-01-01

    This is a tutorial/diagnostic system for training personnel in the use of the Space Shuttle Main Engine Controller (SSMEC) Simulation Lab. It also provides a diagnostic capable of isolating lab failures at least to the major lab component. The system was implemented using Hypercard, which is an program of hypermedia running on Apple Macintosh computers. Hypercard proved to be a viable platform for the development and use of sophisticated tutorial systems and moderately capable diagnostic systems. This tutorial/diagnostic system uses the basic Hypercard tools to provide the tutorial. The diagnostic part of the system uses a simple interpreter written in the Hypercard language (Hypertalk) to implement the backward chaining rule based logic commonly found in diagnostic systems using Prolog. Some of the advantages of Hypercard in developing this type of system include sophisticated graphics, animation, sound and voice capabilities, its ability as a hypermedia tool, and its ability to include digitized pictures. The major disadvantage is the slow execution time for evaluation of rules (due to the interpretive processing of the language). Other disadvantages include the limitation on the size of the cards, that color is not supported, that it does not support grey scale graphics, and its lack of selectable fonts for text fields.

  9. Technological Innovations for High-Throughput Approaches to In Vitro Allergy Diagnosis.

    PubMed

    Chapman, Martin D; Wuenschmann, Sabina; King, Eva; Pomés, Anna

    2015-07-01

    Allergy diagnostics is being transformed by the advent of in vitro IgE testing using purified allergen molecules, combined with multiplex technology and biosensors, to deliver discriminating, sensitive, and high-throughput molecular diagnostics at the point of care. Essential elements of IgE molecular diagnostics are purified natural or recombinant allergens with defined purity and IgE reactivity, planar or bead-based multiplex systems to enable IgE to multiple allergens to be measured simultaneously, and, most recently, nanotechnology-based biosensors that facilitate rapid reaction rates and delivery of test results via mobile devices. Molecular diagnostics relies on measurement of IgE to purified allergens, the "active ingredients" of allergenic extracts. Typically, this involves measuring IgE to multiple allergens which is facilitated by multiplex technology and biosensors. The technology differentiates between clinically significant cross-reactive allergens (which could not be deduced by conventional IgE assays using allergenic extracts) and provides better diagnostic outcomes. Purified allergens are manufactured under good laboratory practice and validated using protein chemistry, mass spectrometry, and IgE antibody binding. Recently, multiple allergens (from dog) were expressed as a single molecule with high diagnostic efficacy. Challenges faced by molecular allergy diagnostic companies include generation of large panels of purified allergens with known diagnostic efficacy, access to flexible and robust array or sensor technology, and, importantly, access to well-defined serum panels form allergic patients for product development and validation. Innovations in IgE molecular diagnostics are rapidly being brought to market and will strengthen allergy testing at the point of care.

  10. A recoverable gas-cell diagnostic for the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratkiewicz, A., E-mail: ratkiewicz1@llnl.gov; Berzak Hopkins, L.; Bleuel, D. L.

    2016-11-15

    The high-fluence neutron spectrum produced by the National Ignition Facility (NIF) provides an opportunity to measure the activation of materials by fast-spectrum neutrons. A new large-volume gas-cell diagnostic has been designed and qualified to measure the activation of gaseous substances at the NIF. This in-chamber diagnostic is recoverable, reusable and has been successfully fielded. Data from the qualification of the diagnostic have been used to benchmark an Monte Carlo N-Particle Transport Code simulation describing the downscattered neutron spectrum seen by the gas cell. We present early results from the use of this diagnostic to measure the activation of {sup nat}Xemore » and discuss future work to study the strength of interactions between plasma and nuclei.« less

  11. A recoverable gas-cell diagnostic for the National Ignition Facility

    DOE PAGES

    Ratkiewicz, A.; Hopkins, L. Berzak; Bleuel, D. L.; ...

    2016-08-22

    Here, the high-fluence neutron spectrum produced by the National Ignition Facility (NIF) provides an opportunity to measure the activation of materials by fast-spectrum neutrons. A new large-volume gas-cell diagnostic has been designed and qualified to measure the activation of gaseous substances at the NIF. This in-chamber diagnostic is recoverable, reusable and has been successfully fielded. Data from the qualification of the diagnostic have been used to benchmark an Monte Carlo N-Particle Transport Code simulation describing the downscattered neutron spectrum seen by the gas cell. We present early results from the use of this diagnostic to measure the activation of natXemore » and discuss future work to study the strength of interactions between plasma and nuclei.« less

  12. The ITER bolometer diagnostic: Status and plansa)

    NASA Astrophysics Data System (ADS)

    Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.

    2008-10-01

    A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.

  13. A computerized handheld decision-support system to improve pulmonary embolism diagnosis: a randomized trial.

    PubMed

    Roy, Pierre-Marie; Durieux, Pierre; Gillaizeau, Florence; Legall, Catherine; Armand-Perroux, Aurore; Martino, Ludovic; Hachelaf, Mohamed; Dubart, Alain-Eric; Schmidt, Jeannot; Cristiano, Mirko; Chretien, Jean-Marie; Perrier, Arnaud; Meyer, Guy

    2009-11-17

    Testing for pulmonary embolism often differs from that recommended by evidence-based guidelines. To assess the effectiveness of a handheld clinical decision-support system to improve the diagnostic work-up of suspected pulmonary embolism among patients in the emergency department. Cluster randomized trial. Assignment was by random-number table, providers were not blinded, and outcome assessment was automated. (ClinicalTrials.gov registration number: NCT00188032). 20 emergency departments in France. 1103 and 1768 consecutive outpatients with suspected pulmonary embolism. After a preintervention period involving 20 centers and 1103 patients, in which providers grew accustomed to inputting clinical data into handheld devices and investigators assessed baseline testing, emergency departments were randomly assigned to activation of a decision-support system on the devices (10 centers, 753 patients) or posters and pocket cards that showed validated diagnostic strategies (10 centers, 1015 patients). Appropriateness of diagnostic work-up, defined as any sequence of tests that yielded a posttest probability less than 5% or greater than 85% (primary outcome) or as strict adherence to guideline recommendations (secondary outcome); number of tests per patient (secondary outcome). The proportion of patients who received appropriate diagnostic work-ups was greater during the trial than in the preintervention period in both groups, but the increase was greater in the computer-based guidelines group (adjusted mean difference in increase, 19.3 percentage points favoring computer-based guidelines [95% CI, 2.9 to 35.6 percentage points]; P = 0.023). Among patients with appropriate work-ups, those in the computer-based guidelines group received slightly fewer tests than did patients in the paper guidelines group (mean tests per patient, 1.76 [SD, 0.98] vs. 2.25 [SD, 1.04]; P < 0.001). The study was not designed to show a difference in the clinical outcomes of patients during follow-up. A handheld decision-support system improved diagnostic decision making for patients with suspected pulmonary embolism in the emergency department.

  14. Respiratory Sinus Arrhythmia Predicts Restricted Repetitive Behavior Severity

    ERIC Educational Resources Information Center

    Condy, Emma E.; Scarpa, Angela; Friedman, Bruce H.

    2017-01-01

    In addition to social communication deficits, restricted repetitive behaviors (RRBs) are a key diagnostic feature of autism spectrum disorder (ASD). Dysfunction of the autonomic nervous system (ANS) in ASD has been posited as a mechanism of RRBs; however, most studies investigating ANS activity in ASD have focused on its relation to social…

  15. Secondary hemophagocytic lymphohistiocytosis and severe sepsis/systemic inflammatory response syndrome/multiorgan dysfunction syndrome/macrophage activation syndrome share common intermediate phenotypes on a spectrum of infla

    USDA-ARS?s Scientific Manuscript database

    In an effort to attain earlier diagnoses in children with hemophagocytic lymphohistiocytosis (HLH), the International Histiocyte Society has now broadened their diagnostic criteria to no longer differentiate primary (HLH) and secondary hemophagocytic lymphohistiocytosis (SHLH). Five of the following...

  16. 38 CFR 4.71a - Schedule of ratings-musculoskeletal system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., diagnostic codes 5004 through 5009, rate the disability as rheumatoid arthritis. 5010Arthritis, due to trauma...: See §§ 4.88b and 4.89. 5002Arthritis rheumatoid (atrophic) As an active process: With constitutional... osteoarthritis): Degenerative arthritis established by X-ray findings will be rated on the basis of limitation of...

  17. 38 CFR 4.71a - Schedule of ratings-musculoskeletal system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., diagnostic codes 5004 through 5009, rate the disability as rheumatoid arthritis. 5010Arthritis, due to trauma...: See §§ 4.88b and 4.89. 5002Arthritis rheumatoid (atrophic) As an active process: With constitutional... osteoarthritis): Degenerative arthritis established by X-ray findings will be rated on the basis of limitation of...

  18. 38 CFR 4.71a - Schedule of ratings-musculoskeletal system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., diagnostic codes 5004 through 5009, rate the disability as rheumatoid arthritis. 5010Arthritis, due to trauma...: See §§ 4.88b and 4.89. 5002Arthritis rheumatoid (atrophic) As an active process: With constitutional... osteoarthritis): Degenerative arthritis established by X-ray findings will be rated on the basis of limitation of...

  19. 38 CFR 4.71a - Schedule of ratings-musculoskeletal system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., diagnostic codes 5004 through 5009, rate the disability as rheumatoid arthritis. 5010Arthritis, due to trauma...: See §§ 4.88b and 4.89. 5002Arthritis rheumatoid (atrophic) As an active process: With constitutional... osteoarthritis): Degenerative arthritis established by X-ray findings will be rated on the basis of limitation of...

  20. 38 CFR 4.71a - Schedule of ratings-musculoskeletal system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., diagnostic codes 5004 through 5009, rate the disability as rheumatoid arthritis. 5010Arthritis, due to trauma...: See §§ 4.88b and 4.89. 5002Arthritis rheumatoid (atrophic) As an active process: With constitutional... osteoarthritis): Degenerative arthritis established by X-ray findings will be rated on the basis of limitation of...

  1. Upgrade of JET AE Active Diagnostic for Low Frequency Eigenmodes Detection

    NASA Astrophysics Data System (ADS)

    Puglia, P.; Blanchard, P.; Testa, D.; Fasoli, A.; Aslanyan, V.; Porkolab, M.; Woskov, P.; Ruchko, L.; Galvao, R.; Pires de Sa, W.; Dos Reis, A.; Sharapov, S.; Dowson, S.,; Sheikh, H.; Blackman, T.; Jones, G.; Dorling, S.; Figueiredo, J.; Perez von Thun, C.; JET Collaboration

    2017-10-01

    The upgrade of the Toroidal Alfvén Eigenmode Active Antenna diagnostic at JET was commissioned last year. The new amplifiers have an operational frequency range limited to bands within 10-1000 kHz by a choice of filters. In the last campaigns the AE excitation system was operated on the Alfvénic range of frequencies (f > 80 kHz). For the next campaigns we are proposing operation on the frequency range of 25-50 kHz to excite eigenmodes on the Alfvén-acoustic range (GAMs, BAEs and Alfvén Cascades). The next JET campaigns will involve use of deuterium, tritium and hydrogen, giving a wide range of parameters for the modes to be investigated. Details of the system modifications for operation in this new frequency range and experimental scenarios will be discussed. This work has been carried out within the framework of the EUROfusion Consortium No 633053. Support was provided by the US DOE, FAPESP Project 2011/50773-0, by the Swiss NSF, and also the RCUK Energy Programme [Grant Number EP/P012450/1].

  2. [Virtual clinical diagnosis support system of degenerative stenosis of the lumbar spinal canal].

    PubMed

    Shevelev, I N; Konovalov, N A; Cherkashov, A M; Molodchenkov, A A; Sharamko, T G; Asiutin, D S; Nazarenko, A G

    2013-01-01

    The aim of the study was to develop a virtual clinical diagnostic support system of degenerative lumbar spinal stenosis on database of spine registry. Choice of criteria's for diagnostic system was made on symptom analysis of 298 patients with lumbar spinal stenosis. Also was analysed a group of patient with disc herniation's for sensitivity and specify assessment of developed diagnostic support system. Represented clinical diagnostic support system allows identifying patients with degenerative lumbar spinal stenosis on stage of patient's primary visit. System sensitivity and specify are 90 and 71% respectively. "Online" mode of diagnostic system in structure of spine registry provides maximal availability for specialists, regardless of their locations. Development of tools "medicine 2.0" is the actual direction for carrying out further researches with which carrying out the centralized baea collection by means of specialized registers helps.

  3. A multicentre observational study for early diagnosis of Gaucher disease in patients with Splenomegaly and/or Thrombocytopenia.

    PubMed

    Motta, Irene; Filocamo, Mirella; Poggiali, Erika; Stroppiano, Marina; Dragani, Alfredo; Consonni, Dario; Barcellini, Wilma; Gaidano, Gianluca; Facchini, Luca; Specchia, Giorgina; Cappellini, Maria Domenica

    2016-04-01

    Gaucher disease (GD) is the most common lysosomal disorder resulting from deficient activity of the β-glucosidase enzyme that causes accumulation of glucosylceramide in the macrophage-monocyte system. Notably, because of non-specific symptoms and a lack of awareness, patients with GD experience long diagnostic delays. The aim of this study was to apply a diagnostic algorithm to identify GD type 1 among adults subjects referred to Italian haematology outpatient units because of splenomegaly and/or thrombocytopenia and, eventually, to estimate the prevalence of GD in this selected population. One hundred and ninety-six subjects (61 females, 135 males; mean age 47.8 ± 18.2 years) have been enrolled in the study and tested for β-glucosidase enzyme activity on dried blood spot (DBS). Seven of 196 patients have been diagnosed with GD, (5 females and 2 males) with mean age 31.8 ± 8.2 years, with a prevalence of 3.6% (with a prevalence of 3.6% (I95% CI 1.4-7.2; 1/28 patients) in this population. These results show that the use of an appropriate diagnostic algorithm and a simple diagnostic method, such as DBS, are important tools to facilitate the diagnosis of a rare disease even for not disease-expert physicians. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Hyperthermostable binding molecules on phage: Assay components for point-of-care diagnostics for active tuberculosis infection.

    PubMed

    Zhao, Ning; Spencer, John; Schmitt, Margaret A; Fisk, John D

    2017-03-15

    Tuberculosis is the leading cause of death from infectious disease worldwide. The low sensitivity, extended processing time, and high expense of current diagnostics are major challenges to the detection and treatment of tuberculosis. Mycobacterium tuberculosis ornithine transcarbamylase (Mtb OTC, Rv1656) has been identified in the urine of patients with active TB infection and is a promising target for point-of-care diagnostics. Specific binding proteins with low nanomolar affinities for Mtb OTC were selected from a phage display library built upon a hyperthermostable Sso7d scaffold. Phage particles displaying Sso7d variants were utilized to generate a sandwich ELISA-based assay for Mtb OTC. The assay response is linear between 2 ng/mL and 125 ng/mL recombinant Mtb OTC and has a limit of detection of 400 pg/mL recombinant Mtb OTC. The assay employing a phage-based detection reagent is comparable to commercially-available antibody-based biosensors. Importantly, the assay maintains functionality at both neutral and basic pH in presence of salt and urea over the range of concentrations typical for human urine. Phage-based diagnostic systems may feature improved physical stability and cost of production relative to traditional antibody-based reagents, without sacrificing specificity and sensitivity. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Integrating labview into a distributed computing environment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasemir, K. U.; Pieck, M.; Dalesio, L. R.

    2001-01-01

    Being easy to learn and well suited for a selfcontained desktop laboratory setup, many casual programmers prefer to use the National Instruments Lab-VIEW environment to develop their logic. An ActiveX interface is presented that allows integration into a plant-wide distributed environment based on the Experimental Physics and Industrial Control System (EPICS). This paper discusses the design decisions and provides performance information, especially considering requirements for the Spallation Neutron Source (SNS) diagnostics system.

  6. Monocyte Activation in Immunopathology: Cellular Test for Development of Diagnostics and Therapy.

    PubMed

    Ivanova, Ekaterina A; Orekhov, Alexander N

    2016-01-01

    Several highly prevalent human diseases are associated with immunopathology. Alterations in the immune system are found in such life-threatening disorders as cancer and atherosclerosis. Monocyte activation followed by macrophage polarization is an important step in normal immune response to pathogens and other relevant stimuli. Depending on the nature of the activation signal, macrophages can acquire pro- or anti-inflammatory phenotypes that are characterized by the expression of distinct patterns of secreted cytokines and surface antigens. This process is disturbed in immunopathologies resulting in abnormal monocyte activation and/or bias of macrophage polarization towards one or the other phenotype. Such alterations could be used as important diagnostic markers and also as possible targets for the development of immunomodulating therapy. Recently developed cellular tests are designed to analyze the phenotype and activity of living cells circulating in patient's bloodstream. Monocyte/macrophage activation test is a successful example of cellular test relevant for atherosclerosis and oncopathology. This test demonstrated changes in macrophage activation in subclinical atherosclerosis and breast cancer and could also be used for screening a panel of natural agents with immunomodulatory activity. Further development of cellular tests will allow broadening the scope of their clinical implication. Such tests may become useful tools for drug research and therapy optimization.

  7. Likelihood of cesarean delivery after applying leading active labor diagnostic guidelines.

    PubMed

    Neal, Jeremy L; Lowe, Nancy K; Phillippi, Julia C; Ryan, Sharon L; Knupp, Amy M; Dietrich, Mary S; Thung, Stephen F

    2017-06-01

    Friedman, the United Kingdom's National Institute for Health and Care Excellence (NICE), and the American College of Obstetricians and Gynecologists/Society for Maternal-Fetal Medicine (ACOG/SMFM) support different active labor diagnostic guidelines. Our aims were to compare likelihoods for cesarean delivery among women admitted before vs in active labor by diagnostic guideline (within-guideline comparisons) and between women admitted in active labor per one or more of the guidelines (between-guideline comparisons). Active labor diagnostic guidelines were retrospectively applied to cervical examination data from nulliparous women with spontaneous labor onset (n = 2573). Generalized linear models were used to determine outcome likelihoods within- and between-guideline groups. At admission, 15.7%, 48.3%, and 10.1% of nulliparous women were in active labor per Friedman, NICE, and ACOG/SMFM diagnostic guidelines, respectively. Cesarean delivery was more likely among women admitted before vs in active labor per the Friedman (AOR 1.75 [95% CI 1.08-2.82] or NICE guideline (AOR 2.55 [95% CI 1.84-3.53]). Between guidelines, cesarean delivery was less likely among women admitted in active labor per the NICE guideline, as compared with the ACOG/SMFM guideline (AOR 0.55 [95% CI 0.35-0.88]). Many nulliparous women are admitted to the hospital before active labor onset. These women are significantly more likely to have a cesarean delivery. Diagnosing active labor before admission or before intervention to speed labor may be one component of a multi-faceted approach to decreasing the primary cesarean rate in the United States. The NICE diagnostic guideline is more inclusive than Friedman or ACOG/SMFM guidelines and its use may be the most clinically useful for safely lowering cesarean rates. © 2017 Wiley Periodicals, Inc.

  8. Diagnostic Care: Grade 9. Technology Learning Activity. Teacher Edition. Level 2. Technology Education Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…

  9. Surveillance of avian influenza in the Caribbean through the Caribbean Animal Health Network: surveillance tools and epidemiologic studies.

    PubMed

    Lefrançois, T; Hendrikx, P; Ehrhardt, N; Millien, M; Gomez, L; Gouyet, L; Gaidet, N; Gerbier, G; Vachiéry, N; Petitclerc, F; Carasco-Lacombe, C; Pinarello, V; Ahoussou, S; Levesque, A; Gongora, H V; Trotman, M

    2010-03-01

    The Caribbean region is considered to be at risk for avian influenza (AI) due to a large backyard poultry system, an important commercial poultry production system, the presence of migratory birds, and disparities in the surveillance systems. The Caribbean Animal Health Network (CaribVET) has developed tools to implement AI surveillance in the region with the goals to have 1) a regionally harmonized surveillance protocol and specific web pages for AI surveillance on www.caribvet.net, and 2) an active and passive surveillance for AI in domestic and wild birds. A diagnostic network for the Caribbean, including technology transfer and AI virus molecular diagnostic capability in Guadeloupe (real-time reverse transcription-polymerase chain reaction for the AI virus matrix gene), was developed. Between 2006 and 2009, 627 samples from four Caribbean countries were tested for three circumstances: importation purposes, following a clinical suspicion of AI, or through an active survey of wild birds (mainly waders) during the southward and northward migration periods in Guadeloupe. None of the samples tested were positive, suggesting a limited role of these species in the AI virus ecology in the Caribbean. Following low pathogenic H5N2 outbreaks in the Dominican Republic in 2007, a questionnaire was developed to collect data for a risk analysis of AI spread in the region through fighting cocks. The infection pathway of the Martinique commercial poultry sector by AI, through introduction of infected cocks, was designed, and recommendations were provided to the Caribbean Veterinary Services to improve cock movement control and biosecurity measures. The CaribVET and its organization allowed interaction between diagnostic and surveillance tools on the one hand and epidemiologic studies on the other, both of them developed in congruence with regional strategies. Together, these CaribVET activities contribute to strengthening surveillance of avian influenza virus (AIV) in the Caribbean region and may allow the development of research studies on both AI risk analysis and on AIV ecology.

  10. Fusion-neutron-yield, activation measurements at the Z accelerator: design, analysis, and sensitivity.

    PubMed

    Hahn, K D; Cooper, G W; Ruiz, C L; Fehl, D L; Chandler, G A; Knapp, P F; Leeper, R J; Nelson, A J; Smelser, R M; Torres, J A

    2014-04-01

    We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r(2) decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm(2) and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

  11. Expression and Activation of Horseradish Peroxidase-Protein A/G Fusion Protein in Silkworm Larvae for Diagnostic Purposes.

    PubMed

    Xxxx, Patmawati; Minamihata, Kosuke; Tatsuke, Tsuneyuki; Lee, Jae Man; Kusakabe, Takahiro; Kamiya, Noriho

    2018-06-01

    Recombinant protein production can create artificial proteins with desired functions by introducing genetic modifications to the target proteins. Horseradish peroxidase (HRP) has been used extensively as a reporter enzyme in biotechnological applications; however, recombinant production of HRP has not been very successful, hampering the utilization of HRP with genetic modifications. A fusion protein comprising an antibody binding protein and HRP will be an ideal bio-probe for high-quality HRP-based diagnostic systems. A HRP-protein A/G fusion protein (HRP-pAG) is designed and its production in silkworm (Bombyx mori) is evaluated for the first time. HRP-pAG is expressed in a soluble apo form, and is activated successfully by incubating with hemin. The activated HRP-pAG is used directly for ELISA experiments and retains its activity over 20 days at 4 °C. Moreover, HRP-pAG is modified with biotin by the microbial transglutaminase (MTG) reaction. The biotinylated HRP-pAG is conjugated with streptavidin to form a HRP-pAG multimer and the multimeric HRP-pAG produced higher signals in the ELISA system than monomeric HRP-pAG. The successful production of recombinant HRP in silkworm will contribute to creating novel HRP-based bioconjugates as well as further functionalization of HRP by applying enzymatic post-translational modifications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. An easy-to-use diagnostic system development shell

    NASA Technical Reports Server (NTRS)

    Tsai, L. C.; Ross, J. B.; Han, C. Y.; Wee, W. G.

    1987-01-01

    The Diagnostic System Development Shell (DSDS), an expert system development shell for diagnostic systems, is described. The major objective of building the DSDS is to create a very easy to use and friendly environment for knowledge engineers and end-users. The DSDS is written in OPS5 and CommonLisp. It runs on a VAX/VMS system. A set of domain independent, generalized rules is built in the DSDS, so the users need not be concerned about building the rules. The facts are explicitly represented in a unified format. A powerful check facility which helps the user to check the errors in the created knowledge bases is provided. A judgement facility and other useful facilities are also available. A diagnostic system based on the DSDS system is question driven and can call or be called by other knowledge based systems written in OPS5 and CommonLisp. A prototype diagnostic system for diagnosing a Philips constant potential X-ray system has been built using the DSDS.

  13. Information management of a department of diagnostic imaging.

    PubMed

    Vincenzoni, M; Campioni, P; Vecchioli Scaldazza, A; Capocasa, G; Marano, P

    1998-01-01

    It is well-known that while RIS allows the management of all input and output data of a Radiology service, PACS plays a major role in the management of all radiologic images. However, the two systems should be closely integrated: scheduling of a radiologic exam requires direct automated integration with the system of image management for retrieval of previous exams and storage of the exam just completed. A modern information system of integration of data and radiologic images should be based on an automated work flow management in al its components, being at the same time flexible and compatible with the ward organization to support and computerize each stage of the working process. Similarly, standard protocols (DICOM 3.0, HL7) defined for interfacing with the Diagnostic Imaging (D.I.) department and the other components of modules of a modern HIS, should be used. They ensure the system to be expandable and accessible to ensure share and integration of information with HIS, emergency service or wards. Correct RIS/PACS integration allows a marked improvement in the efficiency of a modern D.I. department with a positive impact on the daily activity, prompt availability of previous data and images with sophisticated handling of diagnostic images to enhance the reporting quality. The increased diffusion of internet and intranet technology predicts future developments still to be discovered.

  14. Can Salivary Acetylcholinesterase be a Diagnostic Biomarker for Alzheimer?

    PubMed

    Bakhtiari, Sedigheh; Moghadam, Nahid Beladi; Ehsani, Marjan; Mortazavi, Hamed; Sabour, Siamak; Bakhshi, Mahin

    2017-01-01

    The loss of brain cholinergic activity is a key phenomenon in the biochemistry of Alzheimer's Disease (AD). Due to the specific biosynthesis of Acetylcholinesterase (AChE) of cholinergic neurons, the enzyme has been proposed as a potential biochemical marker of cholinergic activity. AChE is expressed not only in the Central Nervous System (CNS), Peripheral Nervous System (PNS) and muscles, but also on the surface of blood cells and saliva. This study aimed to measure salivary AChE activity in AD and to determine the feasibility of creating a simple laboratory test for diagnosing such patients. In this cross-sectional study, the recorded data were obtained from 15 Alzheimer's patients on memantine therapy and 15 healthy subjects. Unstimulated whole saliva samples were collected from the participants and salivary levels of AChE activity were determined by using the Ellman colorimetric method. The Mann Whitney U test was used to compare the average (median) of AChE activity between AD and controls. In order to adjust for possible confounding factors, partial correlation coefficient and multivariate linear regressions were used. Although the average of AChE activity in the saliva of people with AD was lower compared to the control group, we found no statistically significant differences using Mann Whitney U test (138 in control group vs. 175 in Alzheimer's patients, p value=0.25). Additionally, no significant differences were observed in the activity of this enzyme in both sexes or with increased age or duration of the disease. After adjusting for age and gender, there was no association between AChE activity and AD (regression coefficient β=0.08; p value= 0.67). Saliva AChE activity was not significantly associated with AD. This study might help in introduce a new diagnostic aid for AD or monitor patients with AD.

  15. Target prioritization and strategy selection for active case-finding of pulmonary tuberculosis: a tool to support country-level project planning.

    PubMed

    Nishikiori, Nobuyuki; Van Weezenbeek, Catharina

    2013-02-02

    Despite the progress made in the past decade, tuberculosis (TB) control still faces significant challenges. In many countries with declining TB incidence, the disease tends to concentrate in vulnerable populations that often have limited access to health care. In light of the limitations of the current case-finding approach and the global urgency to improve case detection, active case-finding (ACF) has been suggested as an important complementary strategy to accelerate tuberculosis control especially among high-risk populations. The present exercise aims to develop a model that can be used for county-level project planning. A simple deterministic model was developed to calculate the number of estimated TB cases diagnosed and the associated costs of diagnosis. The model was designed to compare cost-effectiveness parameters, such as the cost per case detected, for different diagnostic algorithms when they are applied to different risk populations. The model was transformed into a web-based tool that can support national TB programmes and civil society partners in designing ACF activities. According to the model output, tuberculosis active case-finding can be a costly endeavor, depending on the target population and the diagnostic strategy. The analysis suggests the following: (1) Active case-finding activities are cost-effective only if the tuberculosis prevalence among the target population is high. (2) Extensive diagnostic methods (e.g. X-ray screening for the entire group, use of sputum culture or molecular diagnostics) can be applied only to very high-risk groups such as TB contacts, prisoners or people living with human immunodeficiency virus (HIV) infection. (3) Basic diagnostic approaches such as TB symptom screening are always applicable although the diagnostic yield is very limited. The cost-effectiveness parameter was sensitive to local diagnostic costs and the tuberculosis prevalence of target populations. The prioritization of appropriate target populations and careful selection of cost-effective diagnostic strategies are critical prerequisites for rational active case-finding activities. A decision to conduct such activities should be based on the setting-specific cost-effectiveness analysis and programmatic assessment. A web-based tool was developed and is available to support national tuberculosis programmes and partners in the formulation of cost-effective active case-finding activities at the national and subnational levels.

  16. Numerical analysis of PZT rebar active sensing system for structural health monitoring of RC structure

    NASA Astrophysics Data System (ADS)

    Wu, F.; Yi, J.; Li, W. J.

    2014-03-01

    An active sensing diagnostic system for reinforced concrete SHM has been under investigation. Test results show that the system can detect the damage of the structure. To fundamentally understand the damage algorithm and therefore to establish a robust diagnostic method, accurate Finite Element Analysis (FEA) for the system becomes essential. For the system, a rebar with surface bonded PZT under a transient wave load was simulated and analyzed using commercial FEA software. A detailed 2D axi-symmetric model for a rebar attaching PZT was first established. The model simulates the rebar with wedges, an epoxy adhesive layer, as well as a PZT layer. PZT material parameter transformation with high order tensors was discussed due to the format differences between IEEE Standard and ANSYS. The selection of material properties such as Raleigh damping coefficients was discussed. The direct coupled-field analysis type was selected during simulation. The results from simulation matched well with the experimental data. Further simulation for debonding damage detection for concrete beam with the PZT rebar has been performed. And the numerical results have been validated with test results too. The good consistency between two proves that the numerical models were reasonably accurate. Further system optimization has been performed based on these models. By changing PZT layout and size, the output signals could be increased with magnitudes. And the damage detection signals have been found to be increased exponentially with the debonding size of the rebar.

  17. Real-time plasma control based on the ISTTOK tomography diagnostica)

    NASA Astrophysics Data System (ADS)

    Carvalho, P. J.; Carvalho, B. B.; Neto, A.; Coelho, R.; Fernandes, H.; Sousa, J.; Varandas, C.; Chávez-Alarcón, E.; Herrera-Velázquez, J. J. E.

    2008-10-01

    The presently available processing power in generic processing units (GPUs) combined with state-of-the-art programmable logic devices benefits the implementation of complex, real-time driven, data processing algorithms for plasma diagnostics. A tomographic reconstruction diagnostic has been developed for the ISTTOK tokamak, based on three linear pinhole cameras each with ten lines of sight. The plasma emissivity in a poloidal cross section is computed locally on a submillisecond time scale, using a Fourier-Bessel algorithm, allowing the use of the output signals for active plasma position control. The data acquisition and reconstruction (DAR) system is based on ATCA technology and consists of one acquisition board with integrated field programmable gate array (FPGA) capabilities and a dual-core Pentium module running real-time application interface (RTAI) Linux. In this paper, the DAR real-time firmware/software implementation is presented, based on (i) front-end digital processing in the FPGA; (ii) a device driver specially developed for the board which enables streaming data acquisition to the host GPU; and (iii) a fast reconstruction algorithm running in Linux RTAI. This system behaves as a module of the central ISTTOK control and data acquisition system (FIRESIGNAL). Preliminary results of the above experimental setup are presented and a performance benchmarking against the magnetic coil diagnostic is shown.

  18. Non-contact temperature measurements in support of microgravity combustion experiments

    NASA Technical Reports Server (NTRS)

    Greenberg, Paul S.

    1989-01-01

    Recent conceptual advances in the understanding of combustion science fundamentals in the context of microgravity processes and phenomenology have resulted in an increased demand for diagnostic systems of greater sophistication. Owing primarily to the severe operational constraints that accompany the space flight environment, measurement systems to date remain fairly primative in nature. Qualitative pictures provided by photographic recording media comprise the majority of the existing data, the remainder consisting of the output of conventional transducers, such as thermocouples, hot wires, and pressure transducers. The absence of the rather strong influence of buoyant convection renders microgravity combustion phenomena more fragile than their 1-G counterparts. The emphasis was placed on nonperturbing optical diagnostics. Other factors such as limited supplies of expendable reactants, and periods of microgravity time of sufficient duration, coupled with more fundamental questions regarding inherent length and time scales and reproducibility have favored multipoint or multidimensional techniques. While the development of optical diagnostics for application to combustion science is an extremely active area at present, the peculiarities of space flight hardware severely restrict the feasibility of implementing the majority of techniques which are being utilized in terrestrial applications. The additional requirements for system reliability and operational simplicity have tended to promote somewhat less commonly emphasized techniques such as refractive index mapping and molecular Rayleigh scattering, which are briefly discussed.

  19. Venom Protein C activators as diagnostic agents for defects of protein C System.

    PubMed

    Ramzan, Faiqah; Asmat, Andleeb

    2018-06-18

    Background Protein C is a vitamin K dependent plasma zymogen. It prevents clotting by inhibiting clotting by inactivating factor V and factor VIII. Protein C activation pathway involves three steps: (i) Activation of protein C; (ii) Inhibition of coagulation through inactivating factor V and VIII by activated protein C and (iii) Inhibition of activated protein C by plasma protease inhibitors specific for this enzyme. Proteinases converts the zymogen Protein C (PC) of vertebrates into activated PC, which has been detected in several snake venoms. Most PC activators have been purified from venom of snake species belonging to the genera of the Agkistrodon complex. Unlike the physiological thrombin-catalyzed PC activation reaction which requires thrombomodulin as a cofactor, most snake venom activators directly convert the zymogen PC into the catalytically active form which can easily be determined by means of coagulation or chromogenic substrate techniques. Conclusion The fast-acting PC activator Protac® from Agkistrodon contortrix (southern copperhead snake) venom has been found to have broad application in diagnostic practice for the determination of disorders in the PC pathway. Recently, screening assays for the PC pathway have been introduced, based on the observation that the PC pathway is probably the most important physiological barrier against thrombosis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Strategies for adding adaptive learning mechanisms to rule-based diagnostic expert systems

    NASA Technical Reports Server (NTRS)

    Stclair, D. C.; Sabharwal, C. L.; Bond, W. E.; Hacke, Keith

    1988-01-01

    Rule-based diagnostic expert systems can be used to perform many of the diagnostic chores necessary in today's complex space systems. These expert systems typically take a set of symptoms as input and produce diagnostic advice as output. The primary objective of such expert systems is to provide accurate and comprehensive advice which can be used to help return the space system in question to nominal operation. The development and maintenance of diagnostic expert systems is time and labor intensive since the services of both knowledge engineer(s) and domain expert(s) are required. The use of adaptive learning mechanisms to increment evaluate and refine rules promises to reduce both time and labor costs associated with such systems. This paper describes the basic adaptive learning mechanisms of strengthening, weakening, generalization, discrimination, and discovery. Next basic strategies are discussed for adding these learning mechanisms to rule-based diagnostic expert systems. These strategies support the incremental evaluation and refinement of rules in the knowledge base by comparing the set of advice given by the expert system (A) with the correct diagnosis (C). Techniques are described for selecting those rules in the in the knowledge base which should participate in adaptive learning. The strategies presented may be used with a wide variety of learning algorithms. Further, these strategies are applicable to a large number of rule-based diagnostic expert systems. They may be used to provide either immediate or deferred updating of the knowledge base.

  1. Benchmarking Diagnostic Algorithms on an Electrical Power System Testbed

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Narasimhan, Sriram; Poll, Scott; Garcia, David; Wright, Stephanie

    2009-01-01

    Diagnostic algorithms (DAs) are key to enabling automated health management. These algorithms are designed to detect and isolate anomalies of either a component or the whole system based on observations received from sensors. In recent years a wide range of algorithms, both model-based and data-driven, have been developed to increase autonomy and improve system reliability and affordability. However, the lack of support to perform systematic benchmarking of these algorithms continues to create barriers for effective development and deployment of diagnostic technologies. In this paper, we present our efforts to benchmark a set of DAs on a common platform using a framework that was developed to evaluate and compare various performance metrics for diagnostic technologies. The diagnosed system is an electrical power system, namely the Advanced Diagnostics and Prognostics Testbed (ADAPT) developed and located at the NASA Ames Research Center. The paper presents the fundamentals of the benchmarking framework, the ADAPT system, description of faults and data sets, the metrics used for evaluation, and an in-depth analysis of benchmarking results obtained from testing ten diagnostic algorithms on the ADAPT electrical power system testbed.

  2. Practitioner Review: Borderline personality disorder in adolescence--recent conceptualization, intervention, and implications for clinical practice.

    PubMed

    Sharp, Carla; Fonagy, Peter

    2015-12-01

    The past decade has seen an unprecedented increase in research activity on personality disorders (PDs) in adolescents. The increase in research activity, in addition to major nosological systems legitimizing the diagnosis of borderline personality disorder (BPD) in adolescents, highlights the need to communicate new research on adolescent personality problems to practitioners. In this review, we provide up-to-date information on the phenomenology, prevalence, associated clinical problems, etiology, and intervention for BPD in adolescents. Our aim was to provide a clinically useful practitioner review and to dispel long-held myths about the validity, diagnostic utility, and treatability of PDs in adolescents. Alongside providing up-to-date information on the phenomenology, prevalence, and etiology, we also report on associated clinical problems and interventions for adolescent BPD. It is only through early active assessment and identification of youngsters with these problems that a lifetime of personal suffering and health system burden can be reduced or altogether avoided. A variety of evidence-based approaches are now available to treat BPD and related clinical problems in young people. Future research should focus on establishing optimal precision in the diagnostic processes in different treatment settings. © 2015 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and Adolescent Mental Health.

  3. Remediation of petroleum hydrocarbon-contaminated sites by DNA diagnosis-based bioslurping technology.

    PubMed

    Kim, Seungjin; Krajmalnik-Brown, Rosa; Kim, Jong-Oh; Chung, Jinwook

    2014-11-01

    The application of effective remediation technologies can benefit from adequate preliminary testing, such as in lab-scale and Pilot-scale systems. Bioremediation technologies have demonstrated tremendous potential with regards to cost, but they cannot be used for all contaminated sites due to limitations in biological activity. The purpose of this study was to develop a DNA diagnostic method that reduces the time to select contaminated sites that are good candidates for bioremediation. We applied an oligonucleotide microarray method to detect and monitor genes that lead to aliphatic and aromatic degradation. Further, the bioremediation of a contaminated site, selected based on the results of the genetic diagnostic method, was achieved successfully by applying bioslurping in field tests. This gene-based diagnostic technique is a powerful tool to evaluate the potential for bioremediation in petroleum hydrocarbon contaminated soil. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Diagnostic Approach to Ocular Toxoplasmosis

    PubMed Central

    Garweg, Justus G; de Groot-Mijnes, Jolanda DF; Montoya, Jose G

    2011-01-01

    Toxoplasmic retinochoroiditis is deemed a local event, which may fail to evoke a detectable systemic immune response. A correct diagnosis of the disease is a necessary basis for estimating its clinical burden. This is not so difficult in a typical clinical picture. In atypical cases, further diagnostic efforts are to be installed. Although the aqueous humor may be analyzed for specific antibodies or the presence of parasitic DNA, the DNA burden therein is low, and in rare instances a confirmation would necessitate vitreous sampling. A laboratory confirmation of the diagnosis is frustrated by individual differences in the time elapsing between clinical symptoms and activation of specific antibody production, which may result in false negatives. In congenital ocular toxoplasmosis, a delay in the onset of specific local antibody production could reflect immune tolerance. Herein, the authors attempt to provide a simple and practicable algorithm for a clinically tailored diagnostic approach in atypical instances. PMID:21770803

  5. The computation in diagnostics for tokamaks: systems, designs, approaches

    NASA Astrophysics Data System (ADS)

    Krawczyk, Rafał; Linczuk, Paweł; Czarski, Tomasz; Wojeński, Andrzej; Chernyshova, Maryna; Poźniak, Krzysztof; Kolasiński, Piotr; Kasprowicz, Grzegorz; Zabołotny, Wojciech; Kowalska-Strzeciwilk, Ewa; Malinowski, Karol; Gaska, Michał

    2017-08-01

    The requirements given for GEM (Gaseous Electron Multiplier) detector based acquisition system for plasma impurities diagnostics triggered a need for the development of a specialized software and hardware architecture. The amount of computations with latency and throughput restrictions cause that an advanced solution is sought for. In order to provide a mechanism fitting the designated tokamaks, an insight into existing solutions was necessary. In the article there is discussed architecture of systems used for plasma diagnostics and in related scientific fields. The developed solution is compared and contrasted with other diagnostic and control systems. Particular attention is payed to specific requirements for plasma impurities diagnostics in tokamak thermal fusion reactor. Subsequently, the details are presented that justified the choice of the system architecture and the discussion on various approaches is given.

  6. New directions in diagnostic evaluation of insect allergy.

    PubMed

    Golden, David B K

    2014-08-01

    Diagnosis of insect sting allergy and prediction of risk of sting anaphylaxis are often difficult because tests for venom-specific IgE antibodies have a limited positive predictive value and do not reliably predict the severity of sting reactions. Component-resolved diagnosis using recombinant venom allergens has shown promise in improving the specificity of diagnostic testing for insect sting allergy. Basophil activation tests have been explored as more sensitive assays for identification of patients with insect allergy and for prediction of clinical outcomes. Measurement of mast cell mediators reflects the underlying risk for more severe reactions and limited clinical response to treatment. Measurement of IgE to recombinant venom allergens can distinguish cross-sensitization from dual sensitization to honeybee and vespid venoms, thus helping to limit venom immunotherapy to a single venom instead of multiple venoms in many patients. Basophil activation tests can detect venom allergy in patients who show no detectable venom-specific IgE in standard diagnostic tests and can predict increased risk of systemic reactions to venom immunotherapy, and to stings during and after stopping venom immunotherapy. The risk of severe or fatal anaphylaxis to stings can also be predicted by measurement of baseline serum tryptase or other mast cell mediators.

  7. An ontology-driven, diagnostic modeling system.

    PubMed

    Haug, Peter J; Ferraro, Jeffrey P; Holmen, John; Wu, Xinzi; Mynam, Kumar; Ebert, Matthew; Dean, Nathan; Jones, Jason

    2013-06-01

    To present a system that uses knowledge stored in a medical ontology to automate the development of diagnostic decision support systems. To illustrate its function through an example focused on the development of a tool for diagnosing pneumonia. We developed a system that automates the creation of diagnostic decision-support applications. It relies on a medical ontology to direct the acquisition of clinic data from a clinical data warehouse and uses an automated analytic system to apply a sequence of machine learning algorithms that create applications for diagnostic screening. We refer to this system as the ontology-driven diagnostic modeling system (ODMS). We tested this system using samples of patient data collected in Salt Lake City emergency rooms and stored in Intermountain Healthcare's enterprise data warehouse. The system was used in the preliminary development steps of a tool to identify patients with pneumonia in the emergency department. This tool was compared with a manually created diagnostic tool derived from a curated dataset. The manually created tool is currently in clinical use. The automatically created tool had an area under the receiver operating characteristic curve of 0.920 (95% CI 0.916 to 0.924), compared with 0.944 (95% CI 0.942 to 0.947) for the manually created tool. Initial testing of the ODMS demonstrates promising accuracy for the highly automated results and illustrates the route to model improvement. The use of medical knowledge, embedded in ontologies, to direct the initial development of diagnostic computing systems appears feasible.

  8. TFTR diagnostic vacuum controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  9. A new classification system for lesbians: the Dyke Diagnostic Manual.

    PubMed

    Eliason, Michele J

    2010-01-01

    There has been a long-standing need for a diagnostic manual that documents the unique pathological behaviors of lesbians. The Dyke Diagnostic Manual (DDM) is meant to supplement mainstream classification systems used to identify problematic behaviors in heterosexuals. This article presents thirteen uniquely lesbian conditions that are nowhere to be found in heterosexist diagnostic systems. The DDM may help to reduce the pain and suffering found in many lesbian relationships where one or both partners are afflicted.

  10. Design advances of the Core Plasma Thomson Scattering diagnostic for ITER

    NASA Astrophysics Data System (ADS)

    Scannell, R.; Maslov, M.; Naylor, G.; O'Gorman, T.; Kempenaars, M.; Carr, M.; Bilkova, P.; Bohm, P.; Giudicotti, L.; Pasqualotto, R.; Bassan, M.; Vayakis, G.; Walsh, M.; Huxford, R.

    2017-11-01

    The Core Plasma Thomson Scattering (CPTS) diagnostic on ITER performs measurements of the electron temperature and density profiles which are critical to the understanding of the ITER plasma. The diagnostic must satisfy the ITER project requirements, which translate to requirements on performance as well as reliability, safety and engineering. The implications are particularly challenging for beam dump lifetime, the need for continuous active alignment of the diagnostic during operation, allowable neutron flux in the interspace and the protection of the first mirror from plasma deposition. The CPTS design has been evolving over a number of years. One recent improvement is that the collection optics have been modified to include freeform surfaces. These freeform surfaces introduce extra complexity to the manufacturing but provide greater flexibility in the design. The greater flexibility introduced allows for example to lower neutron throughput or use fewer surfaces while improving optical performance. Performance assessment has shown that scattering from a 1064 nm laser will be sufficient to meet the measurement requirements, at least for the system at the start of operations. Optical transmission at λ < 600 nm is expected to degrade over the ITER lifetime due to fibre darkening and deposition on the first mirror. For this reason, it is proposed that the diagnostic should additionally include measurements of TS 'depolarised light' and a 1319 nm laser system. These additional techniques have different spectral and polarisation dependencies compared to scattering from a 1064 nm laser and hence provide greater robustness into the inferred measurements of Te and ne in the core.

  11. Study of Airflow Out of the Mouth During Speech.

    ERIC Educational Resources Information Center

    Catford, J.C.; And Others

    Airflow outside the mouth is diagnostic of articulatory activities in the vocal tract, both total volume-velocity and the distribution of particle velocities over the flow-front being useful for this purpose. A system for recording and displaying both these types of information is described. This consists of a matrix of l6 hot-wire anemometer flow…

  12. Rotordynamic Instability Problems in High-Performance Turbomachinery

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Diagnostic and remedial methods concerning rotordynamic instability problems in high performance turbomachinery are discussed. Instabilities due to seal forces and work-fluid forces are identified along with those induced by rotor bearing systems. Several methods of rotordynamic control are described including active feedback methods, the use of elastometric elements, and the use of hydrodynamic journal bearings and supports.

  13. 21 CFR 890.1375 - Diagnostic electromyograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1375 Diagnostic..., and to monitor and display the electrical activity produced by nerves, for the diagnosis and prognosis...

  14. Rocket Engine Plume Diagnostics at Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Tejwani, Gopal D.; Langford, Lester A.; VanDyke, David B.; McVay, Gregory P.; Thurman, Charles C.

    2003-01-01

    The Stennis Space Center has been at the forefront of development and application of exhaust plume spectroscopy to rocket engine health monitoring since 1989. Various spectroscopic techniques, such as emission, absorption, FTIR, LIF, and CARS, have been considered for application at the engine test stands. By far the most successful technology h a been exhaust plume emission spectroscopy. In particular, its application to the Space Shuttle Main Engine (SSME) ground test health monitoring has been invaluable in various engine testing and development activities at SSC since 1989. On several occasions, plume diagnostic methods have successfully detected a problem with one or more components of an engine long before any other sensor indicated a problem. More often, they provide corroboration for a failure mode, if any occurred during an engine test. This paper gives a brief overview of our instrumentation and computational systems for rocket engine plume diagnostics at SSC. Some examples of successful application of exhaust plume spectroscopy (emission as well as absorption) to the SSME testing are presented. Our on-going plume diagnostics technology development projects and future requirements are discussed.

  15. Microfluidic diagnostics for low-resource settings

    NASA Astrophysics Data System (ADS)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  16. A biocatalytic cascade with several output signals—towards biosensors with different levels of confidence

    PubMed Central

    Guz, Nataliia; Halámek, Jan; Rusling, James F.; Katz, Evgeny

    2014-01-01

    The biocatalytic cascade based on enzyme-catalyzed reactions activated by several biomolecular input signals and producing output signal after each reaction step was developed as an example of a logically reversible information processing system. The model system was designed to mimic the operation of concatenated AND logic gates with optically readable output signals generated at each step of the logic operation. Implications include concurrent bioanalyses and data interpretation for medical diagnostics. PMID:24748446

  17. Introduction to the SPARC Reanalysis Intercomparison Project (S-RIP) and overview of the reanalysis systems

    NASA Astrophysics Data System (ADS)

    Fujiwara, Masatomo; Wright, Jonathon S.; Manney, Gloria L.; Gray, Lesley J.; Anstey, James; Birner, Thomas; Davis, Sean; Gerber, Edwin P.; Harvey, V. Lynn; Hegglin, Michaela I.; Homeyer, Cameron R.; Knox, John A.; Krüger, Kirstin; Lambert, Alyn; Long, Craig S.; Martineau, Patrick; Molod, Andrea; Monge-Sanz, Beatriz M.; Santee, Michelle L.; Tegtmeier, Susann; Chabrillat, Simon; Tan, David G. H.; Jackson, David R.; Polavarapu, Saroja; Compo, Gilbert P.; Dragani, Rossana; Ebisuzaki, Wesley; Harada, Yayoi; Kobayashi, Chiaki; McCarty, Will; Onogi, Kazutoshi; Pawson, Steven; Simmons, Adrian; Wargan, Krzysztof; Whitaker, Jeffrey S.; Zou, Cheng-Zhi

    2017-01-01

    The climate research community uses atmospheric reanalysis data sets to understand a wide range of processes and variability in the atmosphere, yet different reanalyses may give very different results for the same diagnostics. The Stratosphere-troposphere Processes And their Role in Climate (SPARC) Reanalysis Intercomparison Project (S-RIP) is a coordinated activity to compare reanalysis data sets using a variety of key diagnostics. The objectives of this project are to identify differences among reanalyses and understand their underlying causes, to provide guidance on appropriate usage of various reanalysis products in scientific studies, particularly those of relevance to SPARC, and to contribute to future improvements in the reanalysis products by establishing collaborative links between reanalysis centres and data users. The project focuses predominantly on differences among reanalyses, although studies that include operational analyses and studies comparing reanalyses with observations are also included when appropriate. The emphasis is on diagnostics of the upper troposphere, stratosphere, and lower mesosphere. This paper summarizes the motivation and goals of the S-RIP activity and extensively reviews key technical aspects of the reanalysis data sets that are the focus of this activity. The special issue The SPARC Reanalysis Intercomparison Project (S-RIP) in this journal serves to collect research with relevance to the S-RIP in preparation for the publication of the planned two (interim and full) S-RIP reports.

  18. Delamination detection in smart composite beams using Lamb waves

    NASA Astrophysics Data System (ADS)

    Ip, Kim-Ho; Mai, Yiu-Wing

    2004-06-01

    This paper presents a feasibility study on using Lamb waves to detect and locate through-width delamination in fiber-reinforced plastic beams. An active diagnostic system is proposed for clamped-free specimens. It consists of a piezoelectric patch and an accelerometer both mounted near the support. Such a system can locate damage in an absolute sense, that is, a priori knowledge on the response from pristine specimens is not required. The fundamental anti-symmetric Lamb wave mode is chosen as the diagnostic wave. It is generated by applying a voltage in the form of sinusoidal bursts to the piezoelectric patch. The proposed system was applied to locate delaminations in some fabricated Kevlar/epoxy beam specimens. With an appropriate actuating frequency, distortions of waveforms due to boundary reflections can be reduced. Based on their arrival times and the known propagating speed of Lamb waves, the delaminations can be located. The errors associated with the predicted damage positions range from 4.5% to 8.5%.

  19. 21 CFR 890.1850 - Diagnostic muscle stimulator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1850 Diagnostic... electromyograph machine to initiate muscle activity. It is intended for medical purposes, such as to diagnose...

  20. An Assessment of Integrated Health Management (IHM) Frameworks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N. Lybeck; M. Tawfik; L. Bond

    In order to meet the ever increasing demand for energy, the United States nuclear industry is turning to life extension of existing nuclear power plants (NPPs). Economically ensuring the safe, secure, and reliable operation of aging nuclear power plants presents many challenges. The 2009 Light Water Reactor Sustainability Workshop identified online monitoring of active and structural components as essential to the better understanding and management of the challenges posed by aging nuclear power plants. Additionally, there is increasing adoption of condition-based maintenance (CBM) for active components in NPPs. These techniques provide a foundation upon which a variety of advanced onlinemore » surveillance, diagnostic, and prognostic techniques can be deployed to continuously monitor and assess the health of NPP systems and components. The next step in the development of advanced online monitoring is to move beyond CBM to estimating the remaining useful life of active components using prognostic tools. Deployment of prognostic health management (PHM) on the scale of a NPP requires the use of an integrated health management (IHM) framework - a software product (or suite of products) used to manage the necessary elements needed for a complete implementation of online monitoring and prognostics. This paper provides a thoughtful look at the desirable functions and features of IHM architectures. A full PHM system involves several modules, including data acquisition, system modeling, fault detection, fault diagnostics, system prognostics, and advisory generation (operations and maintenance planning). The standards applicable to PHM applications are indentified and summarized. A list of evaluation criteria for PHM software products, developed to ensure scalability of the toolset to an environment with the complexity of a NPP, is presented. Fourteen commercially available PHM software products are identified and classified into four groups: research tools, PHM system development tools, deployable architectures, and peripheral tools.« less

  1. Overcoming limitations of model-based diagnostic reasoning systems

    NASA Technical Reports Server (NTRS)

    Holtzblatt, Lester J.; Marcotte, Richard A.; Piazza, Richard L.

    1989-01-01

    The development of a model-based diagnostic system to overcome the limitations of model-based reasoning systems is discussed. It is noted that model-based reasoning techniques can be used to analyze the failure behavior and diagnosability of system and circuit designs as part of the system process itself. One goal of current research is the development of a diagnostic algorithm which can reason efficiently about large numbers of diagnostic suspects and can handle both combinational and sequential circuits. A second goal is to address the model-creation problem by developing an approach for using design models to construct the GMODS model in an automated fashion.

  2. Collaborative Research: Atmospheric Pressure Microplasma Chemistry-Photon Synergies Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graves, David

    Combining the effects of low temperature, atmospheric pressure microplasmas and microplasma photon sources shows greatly expanded range of applications of each of them. The plasma sources create active chemical species and these can be activated further by addition of photons and associated photochemistry. There are many ways to combine the effects of plasma chemistry and photochemistry, especially if there are multiple phases present. The project combines construction of appropriate test experimental systems, various spectroscopic diagnostics and mathematical modeling.

  3. Roles of laboratories and laboratory systems in effective tuberculosis programmes

    PubMed Central

    van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul

    2007-01-01

    Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219

  4. Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jianchao; Ding, Yonghua, E-mail: yhding@mail.hust.edu.cn; Zhang, Xiaoqing

    2014-11-15

    A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma coremore » and boundary.« less

  5. Real-time diagnostics for a reusable rocket engine

    NASA Technical Reports Server (NTRS)

    Guo, T. H.; Merrill, W.; Duyar, A.

    1992-01-01

    A hierarchical, decentralized diagnostic system is proposed for the Real-Time Diagnostic System component of the Intelligent Control System (ICS) for reusable rocket engines. The proposed diagnostic system has three layers of information processing: condition monitoring, fault mode detection, and expert system diagnostics. The condition monitoring layer is the first level of signal processing. Here, important features of the sensor data are extracted. These processed data are then used by the higher level fault mode detection layer to do preliminary diagnosis on potential faults at the component level. Because of the closely coupled nature of the rocket engine propulsion system components, it is expected that a given engine condition may trigger more than one fault mode detector. Expert knowledge is needed to resolve the conflicting reports from the various failure mode detectors. This is the function of the diagnostic expert layer. Here, the heuristic nature of this decision process makes it desirable to use an expert system approach. Implementation of the real-time diagnostic system described above requires a wide spectrum of information processing capability. Generally, in the condition monitoring layer, fast data processing is often needed for feature extraction and signal conditioning. This is usually followed by some detection logic to determine the selected faults on the component level. Three different techniques are used to attack different fault detection problems in the NASA LeRC ICS testbed simulation. The first technique employed is the neural network application for real-time sensor validation which includes failure detection, isolation, and accommodation. The second approach demonstrated is the model-based fault diagnosis system using on-line parameter identification. Besides these model based diagnostic schemes, there are still many failure modes which need to be diagnosed by the heuristic expert knowledge. The heuristic expert knowledge is implemented using a real-time expert system tool called G2 by Gensym Corp. Finally, the distributed diagnostic system requires another level of intelligence to oversee the fault mode reports generated by component fault detectors. The decision making at this level can best be done using a rule-based expert system. This level of expert knowledge is also implemented using G2.

  6. Electron beam diagnostic system using computed tomography and an annular sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elmer, John W.; Teruya, Alan T.

    2015-08-11

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by themore » annular sensor structure.« less

  7. Electron beam diagnostic system using computed tomography and an annular sensor

    DOEpatents

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  8. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    NASA Astrophysics Data System (ADS)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  9. Development of life prediction capabilities for liquid propellant rocket engines. Post-fire diagnostic system for the SSME system architecture study

    NASA Technical Reports Server (NTRS)

    Gage, Mark; Dehoff, Ronald

    1991-01-01

    This system architecture task (1) analyzed the current process used to make an assessment of engine and component health after each test or flight firing of an SSME, (2) developed an approach and a specific set of objectives and requirements for automated diagnostics during post fire health assessment, and (3) listed and described the software applications required to implement this system. The diagnostic system described is a distributed system with a database management system to store diagnostic information and test data, a CAE package for visual data analysis and preparation of plots of hot-fire data, a set of procedural applications for routine anomaly detection, and an expert system for the advanced anomaly detection and evaluation.

  10. FY2005 Progress Summary and FY2006 Program Plan Statement of Work and Deliverables for Development of High Average Power Diode-Pumped Solid State Lasers, and Complementary Technologies, for Applications in Energy and Defense

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebbers, C

    The primary focus this year was to operate the system with two amplifiers populated with and pumped by eight high power diode arrays. The system was operated for extended run periods which enabled average power testing of components, diagnostics, and controls. These tests were highly successful, with a demonstrated energy level of over 55 joules for 4 cumulative hours at a repetition rate of 10 Hz (average power 0.55 kW). In addition, high average power second harmonic generation was demonstrated, achieving 227 W of 523.5 nm light (22.7 J, 10 Hz, 15 ns, 30 minutes) Plans to achieve higher energymore » levels and average powers are in progress. The dual amplifier system utilizes a 4-pass optical arrangement. The Yb:S-FAP slabs were mounted in aerodynamic aluminum vane structures to allow turbulent helium gas flow across the faces. Diagnostic packages that monitored beam performance were deployed during operation. The laser experiments involved injecting a seed beam from the front end into the system and making four passes through both amplifiers. Beam performance diagnostics monitored the beam on each pass to assess system parameters such as gain and nearfield intensity profiles. This year, an active mirror and wavefront sensor were procured and demonstrated in an off-line facility. The active mirror technology can correct for low order phase distortions at user specified operating conditions (such as repetition rates different than 10 Hz) and is a complementary technology to the static phase plates used in the system for higher order distortions. A picture of the laser system with amplifier No.2 (foreground) and amplifier No.1 (background) is shown in Fig. 1.0.1.1. The control system and diagnostics were recently enhanced for faster processing and allow remote operation of the system. The growth and fabrication of the Yb:S-FAP slabs constituted another major element of our program objectives. Our goal was to produce at least fourteen 4x6 cm2 crystalline slabs. These goals were met. Nine crystal boules were successfully grown to produce 14 slabs. In addition, we have prepared the way to scale the Yb:S-FAP crystals to the next growth diameter (10-inch diameter as opposed to 7-inch diameter). An outside contract was placed with Northrop-Grumman to scaleup the Yb:S-FAP crystal size. The following sections discuss the above accomplishments in more technical detail and are followed by plans and a budget request for FY2006.« less

  11. Diagnostics in Japan's microgravity experiments

    NASA Technical Reports Server (NTRS)

    Kadota, Toshikazu

    1995-01-01

    The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.

  12. DSM-5, ICD-10, ICD-11, the Psychodynamic Diagnostic Manual, and Person-Centered Integrative Diagnosis: An Overview for College Mental Health Therapists

    ERIC Educational Resources Information Center

    Cooper, Stewart E.

    2014-01-01

    Therapists in the field of college mental health counseling commonly voice an ambivalent orientation towards the utilization of formal psychological diagnostic systems yet often use diagnostic terms. Knowledge of the current and emerging diagnostic systems may contribute to greater syntheses of these differing approaches. This article will first…

  13. Novel treatment strategies for brain tumors and metastases

    PubMed Central

    El-Habashy, Salma E.; Nazief, Alaa M.; Adkins, Chris E.; Wen, Ming Ming; El-Kamel, Amal H.; Hamdan, Ahmed M.; Hanafy, Amira S.; Terrell, Tori O.; Mohammad, Afroz S.; Lockman, Paul R.; Nounou, Mohamed Ismail

    2015-01-01

    This review summarizes patent applications in the past 5 years for the management of brain tumors and metastases. Most of the recent patents discuss one of the following strategies: the development of new drug entities that specifically target the brain cells, the blood–brain barrier and the tumor cells, tailor-designing a novel carrier system that is able to perform multitasks and multifunction as a drug carrier, targeting vehicle and even as a diagnostic tool, direct conjugation of a US FDA approved drug with a targeting moiety, diagnostic moiety or PK modifying moiety, or the use of innovative nontraditional approaches such as genetic engineering, stem cells and vaccinations. Until now, there has been no optimal strategy to deliver therapeutic agents to the CNS for the treatment of brain tumors and metastases. Intensive research efforts are actively ongoing to take brain tumor targeting, and novel and targeted CNS delivery systems to potential clinical application. PMID:24998288

  14. Usefulness of a Regional Health Care Information System in primary care: a case study.

    PubMed

    Maass, Marianne C; Asikainen, Paula; Mäenpää, Tiina; Wanne, Olli; Suominen, Tarja

    2008-08-01

    The goal of this paper is to describe some benefits and possible cost consequences of computer based access to specialised health care information. A before-after activity analysis regarding 20 diabetic patients' clinical appointments was performed in a Health Centre in Satakunta region in Finland. Cost data, an interview, time-and-motion studies, and flow charts based on modelling were applied. Access to up-to-date diagnostic information reduced redundant clinical re-appointments, repeated tests, and mail orders for missing data. Timely access to diagnostic information brought about several benefits regarding workflow, patient care, and disease management. These benefits resulted in theoretical net cost savings. The study results indicated that Regional Information Systems may be useful tools to support performance and improve efficiency. However, further studies are required in order to verify how the monetary savings would impact the performance of Health Care Units.

  15. The current and ideal state of anatomic pathology patient safety.

    PubMed

    Raab, Stephen Spencer

    2014-01-01

    An anatomic pathology diagnostic error may be secondary to a number of active and latent technical and/or cognitive components, which may occur anywhere along the total testing process in clinical and/or laboratory domains. For the pathologist interpretive steps of diagnosis, we examine Kahneman's framework of slow and fast thinking to explain different causes of error in precision (agreement) and in accuracy (truth). The pathologist cognitive diagnostic process involves image pattern recognition and a slow thinking error may be caused by the application of different rationally-constructed mental maps of image criteria/patterns by different pathologists. This type of error is partly related to a system failure in standardizing the application of these maps. A fast thinking error involves the flawed leap from image pattern to incorrect diagnosis. In the ideal state, anatomic pathology systems would target these cognitive error causes as well as the technical latent factors that lead to error.

  16. [Rapidly progressive glomerulonephritis: a diagnostic and therapeutic emergency].

    PubMed

    Halfon, Matthieu; Teta, Daniel; Rotman, Samuel; Pruijm, Menno; Humbert, Antoine

    2014-02-26

    Rapidly progressive glomerulonephritis (RPG) is a rare clinical syndrome characterized by kidney damage that can lead to irreversible kidney failure. RPG can be caused by primary glomerular disease or can be part of a systemic autoimmune disorder. All RPG have a similar pathophysiology (proliferation of cells in Bowman's capsule and formation of crescents) and clinical evolution (rapidly progressive kidney failure with proteinuria and an active urine sediment). Immunosuppressive therapy and sometimes plasma exchanges are required. Overall- and kidney survival are closely linked to the blood creatinine level at presentation, the percentage of damaged glomeruli, and to the underlying cause. RPG is therefore a diagnostic and therapeutic emergency that needs quick referral to a nephrologist.

  17. [Autism in children. Speech, behavior and motor activity point to diagnosis].

    PubMed

    Neumärker, K J

    2001-02-01

    Austistic disorders characteristically involve specific impairments of social skills, of the language and of stereotyped body movements. L Kanner and H. Asperger were the first to describe these psychopathologic features, which still form the core of the diagnostic criteria of contemporary psychiatric classification systems, ICD-10 and DSM-IV, in the category pervasive developmental disorders. Useful diagnostic tools have been developed to establish the clinical diagnosis. The results of research point to a predominantly genetic pathogenesis involving a complex interaction of multiple genes. While no causal treatments are available for these heterogenic disorders, there are many therapeutic concepts. Although some treatments may achieve significant improvements, autistic disorders usually mean a lifelong individual impairment.

  18. Computer-aided diagnostic system for diffuse liver diseases with ultrasonography by neural networks

    NASA Astrophysics Data System (ADS)

    Ogawa, K.; Fukushima, M.; Kubota, K.; Hisa, N.

    1998-12-01

    The aim of the study is to establish a computer-aided diagnostic system for diffuse liver diseases such as chronic active hepatitis (CAH) and liver cirrhosis (LC). The authors introduced an artificial neural network in the classification of these diseases. In this system the neural network was trained by feature parameters extracted from B-mode ultrasonic images of normal liver (NL), CAH and LC. For input data the authors used six parameters calculated by a region of interest (ROI) and a parameter calculated by five ROIs in each image. They were variance of pixel values, coefficient of variation, annular Fourier power spectrum, longitudinal Fourier power spectrum which were calculated for the ROI, and variation of the means of the five ROIs. In addition, the authors used two more parameters calculated from a co-occurrence matrix of pixel values in the ROI. The results showed that the neural network classifier was 83.8% in sensitivity for LC, 90.0% in sensitivity for CAH and 93.6% in specificity, and the system was considered to be helpful for clinical and educational use.

  19. Development of a Diagnostic and Remedial Learning System Based on an Enhanced Concept--Effect Model

    ERIC Educational Resources Information Center

    Panjaburees, Patcharin; Triampo, Wannapong; Hwang, Gwo-Jen; Chuedoung, Meechoke; Triampo, Darapond

    2013-01-01

    With the rapid advances in computer technology during recent years, researchers have demonstrated the pivotal influences of computer-assisted diagnostic systems on student learning performance improvement. This research aims to develop a Diagnostic and Remedial Learning System (DRLS) for an algebra course in a Thai lower secondary school context…

  20. Monitoring, characterization and control of chronic, symptomatic malaria infections in rural Zambia through monthly household visits by paid community health workers

    PubMed Central

    2014-01-01

    Background Active, population-wide mass screening and treatment (MSAT) for chronic Plasmodium falciparum carriage to eliminate infectious reservoirs of malaria transmission have proven difficult to apply on large national scales through trained clinicians from central health authorities. Methodology Fourteen population clusters of approximately 1,000 residents centred around health facilities (HF) in two rural Zambian districts were each provided with three modestly remunerated community health workers (CHWs) conducting active monthly household visits to screen and treat all consenting residents for malaria infection with rapid diagnostic tests (RDT). Both CHWs and HFs also conducted passive case detection among residents who self-reported for screening and treatment. Results Diagnostic positivity was higher among symptomatic patients self-reporting to CHWs (42.5%) and HFs (24%) than actively screened residents (20.3%), but spatial and temporal variations of diagnostic positivity were highly consistent across all three systems. However, most malaria infections (55.6%) were identified through active home visits by CHWs rather than self-reporting to CHWs or HFs. Most (62%) malaria infections detected actively by CHWs reported one or more symptoms of illness. Most reports of fever and vomiting, plus more than a quarter of history of fever, headache and diarrhoea, were attributable to malaria infection. The minority of residents who participated >12 times had lower rates of malaria infection and associated symptoms in later contacts but most residents were tested <4 times and high malaria diagnostic positivity (32%) in active surveys, as well as incidence (1.7 detected infections per person per year) persisted in the population. Per capita cost for active service delivery by CHWs was US$5.14 but this would rise to US$10.68 with full community compliance with monthly testing at current levels of transmission, and US$6.25 if pre-elimination transmission levels and negligible treatment costs were achieved. Conclusion Monthly active home visits by CHWs equipped with RDTs were insufficient to eliminate the human infection reservoir in this typical African setting, despite reasonably high LLIN/IRS coverage. However, dramatic impact upon infection and morbidity burden might be attainable and cost-effective if community participation in regular testing could be improved and the substantial, but not necessarily prohibitive, costs are affordable to national programmes. PMID:24678631

  1. Revising the personality disorder diagnostic criteria for the Diagnostic and Statistical Manual of Mental Disorders-Fifth Edition (DSM-V): consider the later life context.

    PubMed

    Balsis, Steve; Segal, Daniel L; Donahue, Cailin

    2009-10-01

    The categorical measurement approach implemented by the Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition (DSM-IV) personality disorder (PD) diagnostic system is theoretically and pragmatically limited. As a result, many prominent psychologists now advocate for a shift away from this approach in favor of more conceptually sound dimensional measurement. This shift is expected to improve the psychometric properties of the personality disorder (PD) diagnostic system and make it more useful for clinicians and researchers. The current article suggests that despite the probable benefits of such a change, several limitations will remain if the new diagnostic system does not closely consider the context of later life. A failure to address the unique challenges associated with the assessment of personality in older adults likely will result in the continued limited validity, reliability, and utility of the Diagnostic and Statistical Manual of Mental Disorders (DSM) system for this growing population. This article discusses these limitations and their possible implications. (c) 2009 APA, all rights reserved.

  2. The development of a post-test diagnostic system for rocket engines

    NASA Technical Reports Server (NTRS)

    Zakrajsek, June F.

    1991-01-01

    An effort was undertaken by NASA to develop an automated post-test, post-flight diagnostic system for rocket engines. The automated system is designed to be generic and to automate the rocket engine data review process. A modular, distributed architecture with a generic software core was chosen to meet the design requirements. The diagnostic system is initially being applied to the Space Shuttle Main Engine data review process. The system modules currently under development are the session/message manager, and portions of the applications section, the component analysis section, and the intelligent knowledge server. An overview is presented of a rocket engine data review process, the design requirements and guidelines, the architecture and modules, and the projected benefits of the automated diagnostic system.

  3. Characterization of systemic disease in primary Sjögren's syndrome: EULAR-SS Task Force recommendations for articular, cutaneous, pulmonary and renal involvements.

    PubMed

    Ramos-Casals, Manuel; Brito-Zerón, Pilar; Seror, Raphaèle; Bootsma, Hendrika; Bowman, Simon J; Dörner, Thomas; Gottenberg, Jacques-Eric; Mariette, Xavier; Theander, Elke; Bombardieri, Stefano; De Vita, Salvatore; Mandl, Thomas; Ng, Wan-Fai; Kruize, Aike; Tzioufas, Athanasios; Vitali, Claudio

    2015-12-01

    To reach a European consensus on the definition and characterization of the main organ-specific extraglandular manifestations in primary SS. The EULAR-SS Task Force Group steering committee agreed to approach SS-related systemic involvement according to the EULAR SS Disease Activity Index (ESSDAI) classification and proposed the preparation of four separate manuscripts: articular, cutaneous, pulmonary and renal ESSDAI involvement; muscular, peripheral nervous system, CNS and haematological ESSDAI involvement; organs not included in the ESSDAI classification; and lymphoproliferative disease. Currently available evidence was obtained by a systematic literature review focused on SS-related systemic features. The following information was summarized for articular, cutaneous, pulmonary and renal involvement: a clear, consensual definition of the clinical feature, a brief epidemiological description including an estimate of the prevalence reported in the main clinical series and a brief list of the key clinical and diagnostic features that could help physicians clearly identify these features. Unfortunately we found that the body of evidence relied predominantly on information retrieved from individual cases, and the scientific information provided was heterogeneous. The analysis of types of involvement was biased due to the unbalanced reporting of severe cases over non-severe cases, although the main sources of bias were the heterogeneous definitions of organ involvement (or even the lack of definition in some studies) and the heterogeneous diagnostic approach used in studies to investigate involvment of each organ. The proposals included in this article are a first step to developing an optimal diagnostic approach to systemic involvement in primary SS and may pave the way for further development of evidence-based diagnostic and therapeutic guidelines. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Aircraft Turbine Engine Control Research at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2014-01-01

    This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

  5. Phenomenology of Schizophrenia and the Representativeness of Modern Diagnostic Criteria.

    PubMed

    Kendler, Kenneth S

    2016-10-01

    This article aims to determine the degree to which modern operationalized diagnostic criteria for schizophrenia reflect the main clinical features of the disorder as described historically by diagnostic experts. Amazon.com, the National Library of Medicine, and Forgottenbooks.com were searched for articles written or translated into English from 1900 to 1960. Clinical descriptions of schizophrenia or dementia praecox appearing in 16 textbooks or review articles published between 1899 and 1956 were reviewed and compared with the criteria for schizophrenia from 6 modern US operationalized diagnostic systems. Twenty prominent symptoms and signs were reported by 5 or more authors. A strong association was seen between the frequency with which the symptoms/signs were reported and the likelihood of their presence in modern diagnostic systems. Of these 20 symptoms/signs, 3 (thought disorder, delusions, and hallucinations) were included in all diagnostic systems and were among the 4 most frequently reported. Three symptoms/signs were added then kept in subsequent criteria: emotional blunting, changes in volition, and changes in social life. Three symptoms/signs were added but then dropped: bizarre delusions, passivity symptoms, and mood incongruity. Eleven symptoms/signs were never included in any diagnostic system. Compared with historical authors, modern criteria favored symptoms over signs. Odd movements and postures, noted by 16 of 18 historical authors, were absent from all modern criteria. DSM-5 criteria contain 6 of the 20 historically noted symptoms/signs. Although modern operationalized criteria for schizophrenia reflect symptoms and signs commonly reported by historical experts, many clinical features emphasized by these experts are absent from modern criteria. This is not necessarily problematic as diagnostic criteria are meant to index rather than thoroughly describe syndromes. However, the lack of correspondence in schizophrenia between historically important symptoms/signs and current diagnostic systems highlights the limitations of clinical evaluations and research studies that restrict the diagnostic assessments to current diagnostic criteria. We should not confuse our DSM diagnostic criteria with the disorders that they were designed to index.

  6. When Less Is More: How Fewer Diagnostic Criteria Can Indicate Greater Severity

    ERIC Educational Resources Information Center

    Cooper, Luke D.; Balsis, Steve

    2009-01-01

    For diagnosing many mental disorders, the current "Diagnostic and Statistical Manual of Mental Disorders" ("DSM") system weights each diagnostic criterion equally--each criterion counts the same toward meeting the diagnostic threshold. Research on the diagnostic efficiency of criteria, however, reveals that some diagnostic criteria are more useful…

  7. Vacuum system design and tritium inventory for the charge exchange diagnostic on the Tokamak Fusion Test Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medley, S.S.

    The application of charge exchange analyzers for the measurement of ion temperature in fusion plasma experiments requires a direct connection between the diagnostic and plasma-discharge vacuum chambers. Differential pumping of the gas load from the diagnostic stripping cell operated at > or approx. = 10/sup -3/ Torr is required to maintain the analyzer chamber at a pressure of < or approx. = 10/sup -6/ Torr. The migration of gases between the diagnostic and plasma vacuum chambers must be minimized. In particular, introduction of the analyzer stripping cell gas into the plasma chamber having a base pressure of < or approx.more » = 10/sup -8/ Torr must be suppressed. The charge exchange diagnostic for the Tokamak Fusion Test Reactor (TFTR) is comprised of two analyzer systems designed to contain a total of 18 independent mass/energy analyzers and one diagnostic neutral beam rated at 80 keV, 15 A. The associated arrays of multiple, interconnected vacuum systems were analyzed using the Vacuum System Transient Simulator (Vsts) computer program which models the transient transport of multigas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced costs, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus.« less

  8. Neural network expert system for X-ray analysis of welded joints

    NASA Astrophysics Data System (ADS)

    Kozlov, V. V.; Lapik, N. V.; Popova, N. V.

    2018-03-01

    The use of intelligent technologies for the automated analysis of product quality is one of the main trends in modern machine building. At the same time, rapid development in various spheres of human activity is experienced by methods associated with the use of artificial neural networks, as the basis for building automated intelligent diagnostic systems. Technologies of machine vision allow one to effectively detect the presence of certain regularities in the analyzed designation, including defects of welded joints according to radiography data.

  9. A national physician survey of diagnostic error in paediatrics.

    PubMed

    Perrem, Lucy M; Fanshawe, Thomas R; Sharif, Farhana; Plüddemann, Annette; O'Neill, Michael B

    2016-10-01

    This cross-sectional survey explored paediatric physician perspectives regarding diagnostic errors. All paediatric consultants and specialist registrars in Ireland were invited to participate in this anonymous online survey. The response rate for the study was 54 % (n = 127). Respondents had a median of 9-year clinical experience (interquartile range (IQR) 4-20 years). A diagnostic error was reported at least monthly by 19 (15.0 %) respondents. Consultants reported significantly less diagnostic errors compared to trainees (p value = 0.01). Cognitive error was the top-ranked contributing factor to diagnostic error, with incomplete history and examination considered to be the principal cognitive error. Seeking a second opinion and close follow-up of patients to ensure that the diagnosis is correct were the highest-ranked, clinician-based solutions to diagnostic error. Inadequate staffing levels and excessive workload were the most highly ranked system-related and situational factors. Increased access to and availability of consultants and experts was the most highly ranked system-based solution to diagnostic error. We found a low level of self-perceived diagnostic error in an experienced group of paediatricians, at variance with the literature and warranting further clarification. The results identify perceptions on the major cognitive, system-related and situational factors contributing to diagnostic error and also key preventative strategies. • Diagnostic errors are an important source of preventable patient harm and have an estimated incidence of 10-15 %. • They are multifactorial in origin and include cognitive, system-related and situational factors. What is New: • We identified a low rate of self-perceived diagnostic error in contrast to the existing literature. • Incomplete history and examination, inadequate staffing levels and excessive workload are cited as the principal contributing factors to diagnostic error in this study.

  10. West Europe Report, Science and Technology

    DTIC Science & Technology

    1986-02-12

    engineering, in building " artificial intel- ligence" (robotics) and in researching life support systems. /9365 CSO: 3698/239 AEROSPACE BRIEFS FOKKER...diabetology. It is primarily a matter of perfecting a reliable and simple diagnostic material to permit diabetics to monitor their own sugar balance...specialties. Bulk products: antibiotics, active substances, sweeteners . 13. Pierrel, Italy 14. Phenoximethylpenicillin, PcV, is one of the more

  11. Rotorcraft technology at Boeing Vertol: Recent advances

    NASA Technical Reports Server (NTRS)

    Shaw, John; Dadone, Leo; Wiesner, Robert

    1988-01-01

    An overview is presented of key accomplishments in the rotorcraft development at Boeing Vertol. Projects of particular significance: high speed rotor development and the Model 360 Advanced Technology Helicopter. Areas addressed in the overview are: advanced rotors with reduced noise and vibration, 3-D aerodynamic modeling, flight control and avionics, active control, automated diagnostics and prognostics, composite structures, and drive systems.

  12. Is there a need for autopsies in the management of fungal disease?

    PubMed

    Knoke, Manfred; Bernhardt, Hannelore; Schwesinger, Günther

    2008-07-01

    The autopsy rates in Germany became low like in other European, American and Asian countries. Main reasons for this development are the lack of acceptance of autopsy in the society as well as in the medical profession, the introduction of a requirement for consent, unclear legal position, the public health system, pressure of costs and a change in the field of activity in pathology with much more diagnostics of surgical and biopsy material. The autopsy is missing with respect to the reliability of causes of death and morbidity statistics and other epidemiological studies. Published data indicate that up to 20-30% of patients who die in hospitals have important diseases/lesions that remain undetected before death but that are found at autopsy. For infectious diseases, the data are similar. Therefore, a higher incidence of invasive fungal infections was found. Some rare fungal disorders are diagnosed by autopsy. Only exact death statistics makes specific health care possible and is cost saving in a public health system in the long term. Autopsy remains an important tool for quality control in medical diagnostic and therapeutic activity. It is also essential for fundamental medical education and further training.

  13. Runaway electron generation and control

    NASA Astrophysics Data System (ADS)

    Esposito, B.; Boncagni, L.; Buratti, P.; Carnevale, D.; Causa, F.; Gospodarczyk Martin-Solis, M., Jr.; Popovic, Z.; Agostini, M.; Apruzzese, G.; Bin, W.; Cianfarani, C.; De Angelis, R.; Granucci, G.; Grosso, A.; Maddaluno, G.; Marocco, D.; Piergotti, V.; Pensa, A.; Podda, S.; Pucella, G.; Ramogida, G.; Rocchi, G.; Riva, M.; Sibio, A.; Sozzi, C.; Tilia, B.; Tudisco, O.; Valisa, M.; FTU Team

    2017-01-01

    We present an overview of FTU experiments on runaway electron (RE) generation and control carried out through a comprehensive set of real-time (RT) diagnostics/control systems and newly installed RE diagnostics. An RE imaging spectrometer system detects visible and infrared synchrotron radiation. A Cherenkov probe measures RE escaping the plasma. A gamma camera provides hard x-ray radial profiles from RE bremsstrahlung interactions in the plasma. Experiments on the onset and suppression of RE show that the threshold electric field for RE generation is larger than that expected according to a purely collisional theory, but consistent with an increase due to synchrotron radiation losses. This might imply a lower density to be targeted with massive gas injection for RE suppression in ITER. Experiments on active control of disruption-generated RE have been performed through feedback on poloidal coils by implementing an RT boundary-reconstruction algorithm evaluated on magnetic moments. The results indicate that the slow plasma current ramp-down and the simultaneous reduction of the reference plasma external radius are beneficial in dissipating the RE beam energy and population, leading to reduced RE interactions with plasma facing components. RE active control is therefore suggested as a possible alternative or complementary technique to massive gas injection.

  14. Pharmacometabolomics Informs Quantitative Radiomics for Glioblastoma Diagnostic Innovation.

    PubMed

    Katsila, Theodora; Matsoukas, Minos-Timotheos; Patrinos, George P; Kardamakis, Dimitrios

    2017-08-01

    Applications of omics systems biology technologies have enormous promise for radiology and diagnostics in surgical fields. In this context, the emerging fields of radiomics (a systems scale approach to radiology using a host of technologies, including omics) and pharmacometabolomics (use of metabolomics for patient and disease stratification and guiding precision medicine) offer much synergy for diagnostic innovation in surgery, particularly in neurosurgery. This synthesis of omics fields and applications is timely because diagnostic accuracy in central nervous system tumors still challenges decision-making. Considering the vast heterogeneity in brain tumors, disease phenotypes, and interindividual variability in surgical and chemotherapy outcomes, we believe that diagnostic accuracy can be markedly improved by quantitative radiomics coupled to pharmacometabolomics and related health information technologies while optimizing economic costs of traditional diagnostics. In this expert review, we present an innovation analysis on a systems-level multi-omics approach toward diagnostic accuracy in central nervous system tumors. For this, we suggest that glioblastomas serve as a useful application paradigm. We performed a literature search on PubMed for articles published in English between 2006 and 2016. We used the search terms "radiomics," "glioblastoma," "biomarkers," "pharmacogenomics," "pharmacometabolomics," "pharmacometabonomics/pharmacometabolomics," "collaborative informatics," and "precision medicine." A list of the top 4 insights we derived from this literature analysis is presented in this study. For example, we found that (i) tumor grading needs to be better refined, (ii) diagnostic precision should be improved, (iii) standardization in radiomics is lacking, and (iv) quantitative radiomics needs to prove clinical implementation. We conclude with an interdisciplinary call to the metabolomics, pharmacy/pharmacology, radiology, and surgery communities that pharmacometabolomics coupled to information technologies (chemoinformatics tools, databases, collaborative systems) can inform quantitative radiomics, thus translating Big Data and information growth to knowledge growth, rational drug development and diagnostics innovation for glioblastomas, and possibly in other brain tumors.

  15. Standards to support information systems integration in anatomic pathology.

    PubMed

    Daniel, Christel; García Rojo, Marcial; Bourquard, Karima; Henin, Dominique; Schrader, Thomas; Della Mea, Vincenzo; Gilbertson, John; Beckwith, Bruce A

    2009-11-01

    Integrating anatomic pathology information- text and images-into electronic health care records is a key challenge for enhancing clinical information exchange between anatomic pathologists and clinicians. The aim of the Integrating the Healthcare Enterprise (IHE) international initiative is precisely to ensure interoperability of clinical information systems by using existing widespread industry standards such as Digital Imaging and Communication in Medicine (DICOM) and Health Level Seven (HL7). To define standard-based informatics transactions to integrate anatomic pathology information to the Healthcare Enterprise. We used the methodology of the IHE initiative. Working groups from IHE, HL7, and DICOM, with special interest in anatomic pathology, defined consensual technical solutions to provide end-users with improved access to consistent information across multiple information systems. The IHE anatomic pathology technical framework describes a first integration profile, "Anatomic Pathology Workflow," dedicated to the diagnostic process including basic image acquisition and reporting solutions. This integration profile relies on 10 transactions based on HL7 or DICOM standards. A common specimen model was defined to consistently identify and describe specimens in both HL7 and DICOM transactions. The IHE anatomic pathology working group has defined standard-based informatics transactions to support the basic diagnostic workflow in anatomic pathology laboratories. In further stages, the technical framework will be completed to manage whole-slide images and semantically rich structured reports in the diagnostic workflow and to integrate systems used for patient care and those used for research activities (such as tissue bank databases or tissue microarrayers).

  16. A perspective of nanotechnology in hypersensitivity reactions including drug allergy.

    PubMed

    Montañez, Maria Isabel; Ruiz-Sanchez, Antonio J; Perez-Inestrosa, Ezequiel

    2010-08-01

    We provide an overview of the application of the concepts of nanoscience and nanotechnology as a novel scientific approach to the area of nanomedicine related to the domain of the immune system. Particular emphasis will be paid to studies on drug allergy reactions. Several well defined chemical structures arranged in the dimension of the nanoscale are currently being studied for biomedical purposes. By interacting with the immune system, some of these show promising applications as vaccines, diagnostic tools and activators/effectors of the immune response. Even a brief listing of some key applications of nanostructured materials shows how broad and intense this area of nanomedicine is. As a result of the development of nanoscience and nanotechnology applied to medicine, new approaches can be envisioned for problems related to the modulation of the immune response, as well as in immunodiagnosis, and to design new tools to solve related medical challenges. Nanoparticles offer unique advantages with which to exploit new properties and for materials to play a major role in new diagnostic techniques and therapies. Fullerene-C60 and multivalent functionalized gold nanoparticles of various sizes have led to new tools and opened up new ways to study and interact with the immune system. Some of the most versatile nanostructures are dendrimers. In their interaction with the immune system they can naturally occurring macromolecules, taking advantage of the fact that dendrimers can be synthesized into nanosized structures. Their multivalence can be successfully exploited in vaccines and diagnostic tests for allergic reactions.

  17. School Before Six: A Diagnostic Approach. Volume II (Revised Edition).

    ERIC Educational Resources Information Center

    Hodgden, Laurel; And Others

    This collection of learning activities, appropriate for preschool and kindergarten children, is the second volume of a 2-volume manual which describes a diagnostic method of teaching young children. The activities are organized according to program areas. A description of each activity includes information on its uses, materials needed, and final…

  18. Self Diagnostic Accelerometer for Mission Critical Health Monitoring of Aircraft and Spacecraft Engines

    NASA Technical Reports Server (NTRS)

    Lekki, John; Tokars, Roger; Jaros, Dave; Riggs, M. Terrence; Evans, Kenneth P.; Gyekenyesi, Andrew

    2009-01-01

    A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.

  19. Update on the DIII-D ECH system: experiments, gyrotrons, advanced diagnostics, and controls

    NASA Astrophysics Data System (ADS)

    Lohr, John; Brambila, Rigoberto; Cengher, Mirela; Gorelov, Yuri; Grosnickle, William; Moeller, Charles; Ponce, Dan; Torrezan, Antonio; Ives, Lawrence; Reed, Michael; Blank, Monica; Felch, Kevin; Parisuaña, Claudia; LeViness, Alexandra

    2017-08-01

    The ECH system on DIII-D is continuing to be upgraded, while simultaneously being operated nearly daily for plasma experiments. The latest major hardware addition is a new 117.5 GHz gyrotron, which generated 1.7 MW for short pulses during factory testing. A new gyrotron control system based on Field Programmable Gate Array (FPGA) technology with very high speed system data acquisition has significantly increased the flexibility and reliability of individual gyrotron operation. We have improved the performance of the fast mirror scanning, both by increasing the scan speeds and by adding new algorithms for controlling the aiming using commands generated by the Plasma Control System (PCS). The system is used for transport studies, ELM control, current profile control, non-inductive current generation, suppression of MHD modes, startup assist, plasma density control, and other applications. A program of protective measures, which has been in place for more than two years, has eliminated damage to hardware and diagnostics caused by overdense operation. Other activities not directly related to fusion research have used the ECH system to test components, study methods for improving production of semiconductor junctions and materials, and test the feasibility of using ground based microwave systems to power satellites into orbit.

  20. National Institute on Alcohol Abuse and Alcoholism and the study of fetal alcohol spectrum disorders. The International Consortium.

    PubMed

    Calhoun, Faye; Attilia, Maria Luisa; Spagnolo, Primavera Alessandra; Rotondo, Claudia; Mancinelli, Rosanna; Ceccanti, Mauro

    2006-01-01

    Fetal alcohol syndrome (FAS) is a large and rapidly increasing public health problem worldwide. Aside the full-blown FAS, multiple terms are used to describe the continuum of effects that result from prenatal exposure to alcohol, including the whole fetal alcohol spectrum disorders (FASD). The revised Institute of Medicine (IOM) Diagnostic Classification System and the diagnostic criteria for FAS and FASD are reported, as well as the formation of the four-state FAS International Consortium and its aims, as the development of an information base that systematizes data collection that helps to determine at-high-risk populations, and to implement and test a scientific-based prevention/intervention model for at risk women. The Consortium was further enlarged, with the inclusion of some more states (including Italy), leading to the formation of the International Consortium for the Investigation of FASD. The objectives of the Consortium are reported, as well as its previous activities, the South Africa and Italy Projects (active case ascertainment initiatives), and its future activities.

  1. Self-assembled gemcitabine-gadolinium nanoparticles for magnetic resonance imaging and cancer therapy.

    PubMed

    Li, Lele; Tong, Rong; Li, Mengyuan; Kohane, Daniel S

    2016-03-01

    Nanoparticles with combined diagnostic and therapeutic functions are promising tools for cancer diagnosis and treatment. Here, we demonstrate a theranostic nanoparticle that integrates an active gemcitabine metabolite and a gadolinium-based magnetic resonance imaging agent via a facile supramolecular self-assembly synthesis, where the anti-cancer drug gemcitabine-5'-monophosphate (a phosphorylated active metabolite of the anti-cancer drug gemcitabine) was used to coordinate with Gd(III) to self-assemble into theranostic nanoparticles. The formulation exhibits a strong T1 contrast signal for magnetic resonance imaging of tumors in vivo, with enhanced retention time. Furthermore, the nanoparticles did not require other inert nanocarriers or excipients and thus had an exceptionally high drug loading (55 wt%), resulting in the inhibition of MDA-MB-231 tumor growth in mice. Recent advances in nanoparticle-based drug delivery systems have spurred the development of "theranostic" multifunctional nanoparticles, which combine therapeutic and diagnostic functionalities in a single formulation. Developing simple and efficient synthetic strategies for the construction of nanotheranostics with high drug loading remains a challenge. Here, we demonstrate a theranostic nanoparticle that integrates high loadings of an active gemcitabine metabolite and a gadolinium-based magnetic resonance imaging agent via a facile synthesis. The nanoparticles were better T1 contrast agents than currently used Gd-DTPA and had prolonged retention in tumor. Moreover they exhibited enhanced in vivo antitumor activity compared to free drug in a breast cancer xenograft mouse model. The strategy provides a scalable way to fabricate nanoparticles that enables enhancement of both therapeutic and diagnostic capabilities. Published by Elsevier Ltd.

  2. Divergent Relationship of Depression Severity to Social Reward Responses Among Patients with Bipolar Versus Unipolar Depression

    PubMed Central

    Sharma, Anup; Satterthwaite, Theodore D.; Vandekar, Lillie; Katchmar, Natalie; Daldal, Aylin; Ruparel, Kosha; A.Elliott, Mark; Baldassano, Claudia; Thase, Michael E.; Gur, Raquel E.; Kable, Joseph W.; Wolf, Daniel H.

    2016-01-01

    Neuroimaging studies of mood disorders demonstrate abnormalities in brain regions implicated in reward processing. However, there is a paucity of research investigating how social rewards affect reward circuit activity in these disorders. Here, we evaluated the relationship of both diagnostic category and dimensional depression severity to reward system function in bipolar and unipolar depression. In total, 86 adults were included, including 24 patients with bipolar depression, 24 patients with unipolar depression, and 38 healthy comparison subjects. Participants completed a social reward task during 3T BOLD fMRI. On average, diagnostic groups did not differ in activation to social reward. However, greater depression severity significantly correlated with reduced bilateral ventral striatum activation to social reward in the bipolar depressed group, but not the unipolar depressed group. In addition, decreased left orbitofrontal cortical activation correlated with more severe symptoms in bipolar depression, but not unipolar depression. These differential dimensional effects resulted in a significant voxelwise group by depression severity interaction. Taken together, these results provide initial evidence that deficits in social reward processing are differentially related to depression severity in the two disorders. PMID:27295401

  3. A comparison of tuberculosis diagnostic systems in a retrospective cohort of HIV-infected children in Rio de Janeiro, Brazil.

    PubMed

    David, Solange Gonçalves; Lovero, Kathryn L; Pombo March, Maria de Fátima B; Abreu, Thalita G; Ruffino Netto, Antonio; Kritski, Afranio L; Sant'Anna, Clemax C

    2017-06-01

    The diagnosis of pediatric tuberculosis (TB) presents many challenges, and is further complicated in HIV-infected patients. While many diagnostic systems have been proposed, there is no pediatric TB diagnosis gold standard. The outcomes of four TB diagnostic systems in HIV-infected children were compared in this study. A retrospective cohort study was conducted at a TB/HIV reference hospital in Rio de Janeiro. HIV-infected pediatric patients evaluated for TB from 1998 to 2010 were reassessed using four diagnostic systems: Kenneth Jones, 1969; Tidjani, 1986; Ben Marais, 2006; Brazilian Ministry of Health, 2010. Results were compared to standardized diagnoses made by an expert panel of physicians. Of the 121 patients in the study cohort, the expert panel diagnosed 64 as TB and 57 as not TB cases. The Tidjani system showed the highest diagnostic accuracy, with and without the inclusion of microbiological data. The Tidjani and Kenneth Jones systems produced fewer false-positives, and the Ben Marais and Ministry of Health fewer false-negatives. Across systems, there was little agreement between TB diagnoses. In HIV-infected pediatric patients, the Ben Marais and Ministry of Health systems are useful for TB diagnostic screening, whereas the Tidjani and Kenneth Jones systems are best used in a reference center setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Built-In Diagnostics (BID) Of Equipment/Systems

    NASA Technical Reports Server (NTRS)

    Granieri, Michael N.; Giordano, John P.; Nolan, Mary E.

    1995-01-01

    Diagnostician(TM)-on-Chip (DOC) technology identifies faults and commands systems reconfiguration. Smart microcontrollers operating in conjunction with other system-control circuits, command self-correcting system/equipment actions in real time. DOC microcontroller generates commands for associated built-in test equipment to stimulate unit of equipment diagnosed, collects and processes response data obtained by built-in test equipment, and performs diagnostic reasoning on response data, using diagnostic knowledge base derived from design data.

  5. Algorithms for Image Analysis and Combination of Pattern Classifiers with Application to Medical Diagnosis

    NASA Astrophysics Data System (ADS)

    Georgiou, Harris

    2009-10-01

    Medical Informatics and the application of modern signal processing in the assistance of the diagnostic process in medical imaging is one of the more recent and active research areas today. This thesis addresses a variety of issues related to the general problem of medical image analysis, specifically in mammography, and presents a series of algorithms and design approaches for all the intermediate levels of a modern system for computer-aided diagnosis (CAD). The diagnostic problem is analyzed with a systematic approach, first defining the imaging characteristics and features that are relevant to probable pathology in mammo-grams. Next, these features are quantified and fused into new, integrated radio-logical systems that exhibit embedded digital signal processing, in order to improve the final result and minimize the radiological dose for the patient. In a higher level, special algorithms are designed for detecting and encoding these clinically interest-ing imaging features, in order to be used as input to advanced pattern classifiers and machine learning models. Finally, these approaches are extended in multi-classifier models under the scope of Game Theory and optimum collective deci-sion, in order to produce efficient solutions for combining classifiers with minimum computational costs for advanced diagnostic systems. The material covered in this thesis is related to a total of 18 published papers, 6 in scientific journals and 12 in international conferences.

  6. Smart signal processing for an evolving electric grid

    NASA Astrophysics Data System (ADS)

    Silva, Leandro Rodrigues Manso; Duque, Calos Augusto; Ribeiro, Paulo F.

    2015-12-01

    Electric grids are interconnected complex systems consisting of generation, transmission, distribution, and active loads, recently called prosumers as they produce and consume electric energy. Additionally, these encompass a vast array of equipment such as machines, power transformers, capacitor banks, power electronic devices, motors, etc. that are continuously evolving in their demand characteristics. Given these conditions, signal processing is becoming an essential assessment tool to enable the engineer and researcher to understand, plan, design, and operate the complex and smart electronic grid of the future. This paper focuses on recent developments associated with signal processing applied to power system analysis in terms of characterization and diagnostics. The following techniques are reviewed and their characteristics and applications discussed: active power system monitoring, sparse representation of power system signal, real-time resampling, and time-frequency (i.e., wavelets) applied to power fluctuations.

  7. The JET diagnostic fast central acquisition and trigger system (abstract)

    NASA Astrophysics Data System (ADS)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  8. Diagnostics of wear in aeronautical systems

    NASA Technical Reports Server (NTRS)

    Wedeven, L. D.

    1979-01-01

    The use of appropriate diagnostic tools for aircraft oil wetted components is reviewed, noting that it can reduce direct operating costs through reduced unscheduled maintenance, particularly in helicopter engine and transmission systems where bearing failures are a significant cost factor. Engine and transmission wear modes are described, and diagnostic methods for oil and wet particle analysis, the spectrometric oil analysis program, chip detectors, ferrography, in-line oil monitor and radioactive isotope tagging are discussed, noting that they are effective over a limited range of particle sizes but compliment each other if used in parallel. Fine filtration can potentially increase time between overhauls, but reduces the effectiveness of conventional oil monitoring techniques so that alternative diagnostic techniques must be used. It is concluded that the development of a diagnostic system should be parallel and integral with the development of a mechanical system.

  9. The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

    NASA Technical Reports Server (NTRS)

    Ricks, Brian W.; Mengshoel, Ole J.

    2009-01-01

    Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

  10. Assessment of the biological activity of soils in the subtropical zone of Azerbaijan

    NASA Astrophysics Data System (ADS)

    Babaev, M. P.; Orujova, N. I.

    2009-10-01

    The enzymatic activity; the microbial population; and the intensities of the nitrification, ammonification, CO2emission, and cellulose decomposition were studied in gray-brown, meadow-sierozemic, meadow-forest alluvial, and yellow (zheltozem) gley soils in the subtropical zone of Azerbaijan under natural vegetation, crop rotation systems with vegetables, and permanent vegetable crops. On this basis, the biological diagnostics of these soils were suggested and the soil ecological health was evaluated. It was shown that properly chosen crop rotation systems on irrigated lands make it possible to preserve the fertility of the meadow-forest alluvial and zheltozem-gley soils and to improve the fertility of the gray-brown and meadow-sierozemic soils.

  11. A Scalable, Out-of-Band Diagnostics Architecture for International Space Station Systems Support

    NASA Technical Reports Server (NTRS)

    Fletcher, Daryl P.; Alena, Rick; Clancy, Daniel (Technical Monitor)

    2002-01-01

    The computational infrastructure of the International Space Station (ISS) is a dynamic system that supports multiple vehicle subsystems such as Caution and Warning, Electrical Power Systems and Command and Data Handling (C&DH), as well as scientific payloads of varying size and complexity. The dynamic nature of the ISS configuration coupled with the increased demand for payload support places a significant burden on the inherently resource constrained computational infrastructure of the ISS. Onboard system diagnostics applications are hosted on computers that are elements of the avionics network while ground-based diagnostic applications receive only a subset of available telemetry, down-linked via S-band communications. In this paper we propose a scalable, out-of-band diagnostics architecture for ISS systems support that uses a read-only connection for C&DH data acquisition, which provides a lower cost of deployment and maintenance (versus a higher criticality readwrite connection). The diagnostics processing burden is off-loaded from the avionics network to elements of the on-board LAN that have a lower overall cost of operation and increased computational capacity. A superset of diagnostic data, richer in content than the configured telemetry, is made available to Advanced Diagnostic System (ADS) clients running on wireless handheld devices, affording the crew greater mobility for troubleshooting and providing improved insight into vehicle state. The superset of diagnostic data is made available to the ground in near real-time via an out-of band downlink, providing a high level of fidelity between vehicle state and test, training and operational facilities on the ground.

  12. Diagnostic accuracy of sleep bruxism scoring in absence of audio-video recording: a pilot study.

    PubMed

    Carra, Maria Clotilde; Huynh, Nelly; Lavigne, Gilles J

    2015-03-01

    Based on the most recent polysomnographic (PSG) research diagnostic criteria, sleep bruxism is diagnosed when >2 rhythmic masticatory muscle activity (RMMA)/h of sleep are scored on the masseter and/or temporalis muscles. These criteria have not yet been validated for portable PSG systems. This pilot study aimed to assess the diagnostic accuracy of scoring sleep bruxism in absence of audio-video recordings. Ten subjects (mean age 24.7 ± 2.2) with a clinical diagnosis of sleep bruxism spent one night in the sleep laboratory. PSG were performed with a portable system (type 2) while audio-video was recorded. Sleep studies were scored by the same examiner three times: (1) without, (2) with, and (3) without audio-video in order to test the intra-scoring and intra-examiner reliability for RMMA scoring. The RMMA event-by-event concordance rate between scoring without audio-video and with audio-video was 68.3 %. Overall, the RMMA index was overestimated by 23.8 % without audio-video. However, the intra-class correlation coefficient (ICC) between scorings with and without audio-video was good (ICC = 0.91; p < 0.001); the intra-examiner reliability was high (ICC = 0.97; p < 0.001). The clinical diagnosis of sleep bruxism was confirmed in 8/10 subjects based on scoring without audio-video and in 6/10 subjects with audio-video. Although the absence of audio-video recording, the diagnostic accuracy of assessing RMMA with portable PSG systems appeared to remain good, supporting their use for both research and clinical purposes. However, the risk of moderate overestimation in absence of audio-video must be taken into account.

  13. A Statistical Evaluation of the Diagnostic Performance of MEDAS-The Medical Emergency Decision Assistance System

    PubMed Central

    Georgakis, D. Christine; Trace, David A.; Naeymi-Rad, Frank; Evens, Martha

    1990-01-01

    Medical expert systems require comprehensive evaluation of their diagnostic accuracy. The usefulness of these systems is limited without established evaluation methods. We propose a new methodology for evaluating the diagnostic accuracy and the predictive capacity of a medical expert system. We have adapted to the medical domain measures that have been used in the social sciences to examine the performance of human experts in the decision making process. Thus, in addition to the standard summary measures, we use measures of agreement and disagreement, and Goodman and Kruskal's λ and τ measures of predictive association. This methodology is illustrated by a detailed retrospective evaluation of the diagnostic accuracy of the MEDAS system. In a study using 270 patients admitted to the North Chicago Veterans Administration Hospital, diagnoses produced by MEDAS are compared with the discharge diagnoses of the attending physicians. The results of the analysis confirm the high diagnostic accuracy and predictive capacity of the MEDAS system. Overall, the agreement of the MEDAS system with the “gold standard” diagnosis of the attending physician has reached a 90% level.

  14. 40 CFR 86.1717-99 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-99 Section 86.1717-99 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...

  15. 40 CFR 86.1717-01 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-01 Section 86.1717-01 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...

  16. 40 CFR 86.1717-99 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-99 Section 86.1717-99 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...

  17. 40 CFR 86.1717-01 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-01 Section 86.1717-01 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...

  18. Breast Cancer Diagnostic System Final Report CRADA No. TC02098.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rubenchik, A. M.; DaSilva, L. B.

    This was a collaborative effort between Lawrence Livermore National Security, LLC (formerly The Regents of the University of California)/Lawrence Liver more National Laboratory (LLNL) and BioTelligent, Inc. together with a Russian Institution (BioFil, Ltd.), to develop a new system ( diagnostic device, operating procedures, algorithms and software) to accurately distinguish between benign and malignant breast tissue (Breast Cancer Diagnostic System, BCDS).

  19. Using Targeted Active-Learning Exercises and Diagnostic Question Clusters to Improve Students' Understanding of Carbon Cycling in Ecosystems

    ERIC Educational Resources Information Center

    Maskiewicz, April Cordero; Griscom, Heather Peckham; Welch, Nicole Turrill

    2012-01-01

    In this study, we used targeted active-learning activities to help students improve their ways of reasoning about carbon flow in ecosystems. The results of a validated ecology conceptual inventory (diagnostic question clusters [DQCs]) provided us with information about students' understanding of and reasoning about transformation of inorganic and…

  20. Diagnostic reference level: an important tool for reducing radiation doses in adult and pediatric nuclear medicine procedures in Brazil.

    PubMed

    Willegaignon, José; Braga, Luis F E F; Sapienza, Marcelo T; Coura-Filho, George B; Cardona, Marissa A R; Alves, Carlos E R; Gutterres, Ricardo F; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to establish a concise method for determining a diagnostic reference level (DRL) for adult and pediatric nuclear medicine patients on the basis of diagnostic procedures and administered radioisotope as a means of controlling medical exposure. A screening was carried out in all Brazilian Nuclear Medicine Service (NMS) establishments to support this study by collecting the average activities administered during adult diagnostic procedures and the rules applied to adjust these according to the patient's age and body mass. Percentile 75 was used in all the activities administered as a means of establishing DRL for adult patients, with additional correction factors for pediatric patients. Radiation doses from nuclear medicine procedures on the basis of average administered activity were calculated for all diagnostic exams. A total of 107 NMSs in Brazil agreed to participate in the project. From the 64 nuclear medicine procedures studied, bone, kidney, and parathyroid scans were found to be used in more than 85% of all the NMSs analyzed. There was a large disparity among the activities administered, when applying the same procedures, this reaching, in some cases, more than 20 times between the lowest and the highest. Diagnostic exams based on Ga, Tl, and I radioisotopes proved to be the major exams administering radiation doses to patients. On introducing the DRL concept into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. Variability in the available diagnostic procedures as well as in the amount of activities administered within the same procedure was appreciable not only in Brazil, but worldwide. Global efforts are needed to establish a concise DRL that can be applied in adult and pediatric nuclear medicine procedures as the application of DRL in clinical routine has been proven to be an important tool for controlling and reducing radiation doses received by patients in medical exposure.

  1. Application Of The CSRL Language To The Design Of Diagnostic Expert Systems: The Moodis Experience, A Preliminary Report

    NASA Astrophysics Data System (ADS)

    Bravos, Angelo; Hill, Howard; Choca, James; Bresolin, Linda B.; Bresolin, Michael J.

    1986-03-01

    Computer technology is rapidly becoming an inseparable part of many health science specialties. Recently, a new area of computer technology, namely Artificial Intelligence, has been applied toward assisting the medical experts in their diagnostic and therapeutic decision making process. MOODIS is an experimental diagnostic expert system which assists Psychiatry specialists in diagnosing human Mood Disorders, better known as Affective Disorders. Its diagnostic methodology is patterned after MDX, a diagnostic expert system developed at LAIR (Laboratory for Artificial Intelligence Research) of Ohio State University. MOODIS is implemented in CSRL (Conceptual Structures Representation Language) also developed at LAIR. This paper describes MOODIS in terms of conceptualization and requirements, and discusses why the MDX approach and CSRL were chosen.

  2. Circulating Tumor Cells: What Is in It for the Patient? A Vision towards the Future

    PubMed Central

    van de Stolpe, Anja; den Toonder, Jaap M. J.

    2014-01-01

    Knowledge on cellular signal transduction pathways as drivers of cancer growth and metastasis has fuelled development of “targeted therapy” which “targets” aberrant oncogenic signal transduction pathways. These drugs require nearly invariably companion diagnostic tests to identify the tumor-driving pathway and the cause of the abnormal pathway activity in a tumor sample, both for therapy response prediction as well as for monitoring of therapy response and emerging secondary drug resistance. Obtaining sufficient tumor material for this analysis in the metastatic setting is a challenge, and circulating tumor cells (CTCs) may provide an attractive alternative to biopsy on the premise that they can be captured from blood and the companion diagnostic test results are correctly interpreted. We discuss novel companion diagnostic directions, including the challenges, to identify the tumor driving pathway in CTCs, which in combination with a digital pathology platform and algorithms to quantitatively interpret complex CTC diagnostic results may enable optimized therapy response prediction and monitoring. In contrast to CTC-based companion diagnostics, CTC enumeration is envisioned to be largely replaced by cell free tumor DNA measurements in blood for therapy response and recurrence monitoring. The recent emergence of novel in vitro human model systems in the form of cancer-on-a-chip may enable elucidation of some of the so far elusive characteristics of CTCs, and is expected to contribute to more efficient CTC capture and CTC-based diagnostics. PMID:24879438

  3. Complex interferometry potential in case of sufficiently stable diagnostic system

    NASA Astrophysics Data System (ADS)

    Kalal, M.

    2016-06-01

    Classical interferometry is one of the key methods among active optical diagnostics. Its more advanced version, which allows recording and subsequent reconstruction of up to three sets of data using just one data object —a complex interferogram—was developed in the past and became known as complex interferometry. Employing this diagnostics, not only the usual phase shift, but also the amplitude of the probing beam as well as the fringe contrast (leading directly to the phase shift time derivative) can be reconstructed simultaneously from such a complex interferogram. In this paper it will be demonstrated that even in the case of a not particularly good diagnostic beam quality these three quantities can be reconstructed with a high degree of accuracy provided both the diagnostic beam as well as the corresponding optical line feature a reasonable stability. Such stability requirement is important as in an ideal case four shots need to be gradually recorded (one by one): the signal complex interferogram, the reference interferogram as well as the intensity structures of the signal and reference part of the diagnostic beam. Two examples of complex interferograms obtained in experiments will be analyzed: the laser produced plasma (spark in the air) and the high pressure gas jet. A general ray-tracing based iterative algorithm will be outlined in order to increase a precision of the index of refraction spatial profile taking into account refraction effects (omitted in the Abel inversion) and employing the original reconstructed phase shift and amplitude.

  4. Brefeldin A Inhibits Cell-Free, De Novo Synthesis of Poliovirus

    PubMed Central

    Cuconati, Andrea; Molla, Akhteruzzaman; Wimmer, Eckard

    1998-01-01

    Brefeldin A (BFA), an inhibitor of intracellular vesicle-dependent secretory transport, is a potent inhibitor of poliovirus RNA replication in infected cells. We have determined that the unknown mechanism of BFA inhibition of replication is reproduced in the cell-free poliovirus translation, replication, and encapsidation system. Furthermore, we provide evidence suggesting that the cellular mechanism targeted by BFA, the GTP-dependent synthesis of secretory transport vesicles, may be involved in viral RNA replication in the system via a soluble cellular GTP-binding and -hydrolyzing activity. This activity is related to the ARF (ADP-ribosylation factor) family of GTP-binding proteins. ARFs are required for the formation of several classes of secretory vesicles, and some family members are indirectly inactivated by BFA. Peptides that function as competitive inhibitors of ARF activity in cell-free transport systems also inhibit poliovirus RNA replication, and this inhibitory effect can be countered by the addition of exogenous ARF. We suggest that BFA inhibition of replication is diagnostic of a requirement for ARF activity in the cell-free system. PMID:9658088

  5. [Zoological diagnostics of soils: imperatives, purposes, and place within soil zoology and pedology].

    PubMed

    Mordokovich, V G

    2013-01-01

    Zoological diagnostics of soils was conceived by M.S. Ghilarov as a part of soil zoology and intended to be closely related to pedology. He considered zoo-agents as an ecological factor, one among many others, of soil formation. Contemporary soil diagnostics pursues mostly utilitarian goals and is based on conservative properties of the stable part of soil substrate. However, it is admitted that these properties are generated by specific combinations of biological, chemical, and physical phenomena that are called "elementary soil processes" (ESP) and occur nowhere but in soils. Certain ESPs are associated with distinctive combinations of biota, including invertebrates. Pedobionts act as producers of detritus and contribute to humus formation, which is necessary for any ESP starting, thus being its active party. That is why animals, being the most complex and active part of the ESP system, may be treated not only as its indicators but also as its navigators. Monitoring and studying of ESPs in soil is complicated because of inevitable disturbance of soil profile natural composition. Zoo-agents, at the same time, can be registered without habitats changing. Taking into account ecological potency of soil invertebrates that participate in an ESP, spectra of their eco-groups, life forms, and results of their activity, it is possible to diagnose a soil state at different stages of certain ESPs development, with their different combinations, and in different regions or parts of natural environmental gradients.

  6. A diagnostic algorithm to optimize data collection and interpretation of Ripple Maps in atrial tachycardias.

    PubMed

    Koa-Wing, Michael; Nakagawa, Hiroshi; Luther, Vishal; Jamil-Copley, Shahnaz; Linton, Nick; Sandler, Belinda; Qureshi, Norman; Peters, Nicholas S; Davies, D Wyn; Francis, Darrel P; Jackman, Warren; Kanagaratnam, Prapa

    2015-11-15

    Ripple Mapping (RM) is designed to overcome the limitations of existing isochronal 3D mapping systems by representing the intracardiac electrogram as a dynamic bar on a surface bipolar voltage map that changes in height according to the electrogram voltage-time relationship, relative to a fiduciary point. We tested the hypothesis that standard approaches to atrial tachycardia CARTO™ activation maps were inadequate for RM creation and interpretation. From the results, we aimed to develop an algorithm to optimize RMs for future prospective testing on a clinical RM platform. CARTO-XP™ activation maps from atrial tachycardia ablations were reviewed by two blinded assessors on an off-line RM workstation. Ripple Maps were graded according to a diagnostic confidence scale (Grade I - high confidence with clear pattern of activation through to Grade IV - non-diagnostic). The RM-based diagnoses were corroborated against the clinical diagnoses. 43 RMs from 14 patients were classified as Grade I (5 [11.5%]); Grade II (17 [39.5%]); Grade III (9 [21%]) and Grade IV (12 [28%]). Causes of low gradings/errors included the following: insufficient chamber point density; window-of-interest<100% of cycle length (CL); <95% tachycardia CL mapped; variability of CL and/or unstable fiducial reference marker; and suboptimal bar height and scar settings. A data collection and map interpretation algorithm has been developed to optimize Ripple Maps in atrial tachycardias. This algorithm requires prospective testing on a real-time clinical platform. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. A Review of Diagnostic Techniques for ISHM Applications

    NASA Technical Reports Server (NTRS)

    Patterson-Hine, Ann; Biswas, Gautam; Aaseng, Gordon; Narasimhan, Sriam; Pattipati, Krishna

    2005-01-01

    System diagnosis is an integral part of any Integrated System Health Management application. Diagnostic applications make use of system information from the design phase, such as safety and mission assurance analysis, failure modes and effects analysis, hazards analysis, functional models, fault propagation models, and testability analysis. In modern process control and equipment monitoring systems, topological and analytic , models of the nominal system, derived from design documents, are also employed for fault isolation and identification. Depending on the complexity of the monitored signals from the physical system, diagnostic applications may involve straightforward trending and feature extraction techniques to retrieve the parameters of importance from the sensor streams. They also may involve very complex analysis routines, such as signal processing, learning or classification methods to derive the parameters of importance to diagnosis. The process that is used to diagnose anomalous conditions from monitored system signals varies widely across the different approaches to system diagnosis. Rule-based expert systems, case-based reasoning systems, model-based reasoning systems, learning systems, and probabilistic reasoning systems are examples of the many diverse approaches ta diagnostic reasoning. Many engineering disciplines have specific approaches to modeling, monitoring and diagnosing anomalous conditions. Therefore, there is no "one-size-fits-all" approach to building diagnostic and health monitoring capabilities for a system. For instance, the conventional approaches to diagnosing failures in rotorcraft applications are very different from those used in communications systems. Further, online and offline automated diagnostic applications are integrated into an operations framework with flight crews, flight controllers and maintenance teams. While the emphasis of this paper is automation of health management functions, striking the correct balance between automated and human-performed tasks is a vital concern.

  8. Multimodality approach to classifying hand utilization for the clinical breast examination.

    PubMed

    Laufer, Shlomi; Cohen, Elaine R; Maag, Anne-Lise D; Kwan, Calvin; Vanveen, Barry; Pugh, Carla M

    2014-01-01

    The clinical breast examination (CBE) is performed to detect breast pathology. However, little is known regarding clinical technique and how it relates to diagnostic accuracy. We sought to quantify breast examination search patterns and hand utilization with a new data collection and analysis system. Participants performed the CBE while the sensor mapping and video camera system collected performance data. From this data, algorithms were developed that measured the number of hands used during the exam and active examination time. This system is a feasible and reliable method to collect new information on CBE techniques.

  9. Propagation of nuclear data uncertainties for fusion power measurements

    NASA Astrophysics Data System (ADS)

    Sjöstrand, Henrik; Conroy, Sean; Helgesson, Petter; Hernandez, Solis Augusto; Koning, Arjan; Pomp, Stephan; Rochman, Dimitri

    2017-09-01

    Neutron measurements using neutron activation systems are an essential part of the diagnostic system at large fusion machines such as JET and ITER. Nuclear data is used to infer the neutron yield. Consequently, high-quality nuclear data is essential for the proper determination of the neutron yield and fusion power. However, uncertainties due to nuclear data are not fully taken into account in uncertainty analysis for neutron yield calibrations using activation foils. This paper investigates the neutron yield uncertainty due to nuclear data using the so-called Total Monte Carlo Method. The work is performed using a detailed MCNP model of the JET fusion machine; the uncertainties due to the cross-sections and angular distributions in JET structural materials, as well as the activation cross-sections in the activation foils, are analysed. It is found that a significant contribution to the neutron yield uncertainty can come from uncertainties in the nuclear data.

  10. Analysis of electron temperature, impurity transport and MHD activity with multi-energy soft x-ray diagnostic in EAST tokamak

    NASA Astrophysics Data System (ADS)

    Heng, LAN; Guosheng, XU; Kevin, TRITZ; Ning, YAN; Tonghui, SHI; Yongliang, LI; Tengfei, WANG; Liang, WANG; Jingbo, CHEN; Yanmin, DUAN; Yi, YUAN; Youwen, SUN; Shuai, GU; Qing, ZANG; Ran, CHEN; Liang, CHEN; Xingwei, ZHENG; Shuliang, CHEN; Huan, LIU; Yang, YE; Huiqian, WANG; Baonian, WAN; the EAST Team

    2017-12-01

    A new edge tangential multi-energy soft x-ray (ME-SXR) diagnostic with high temporal (≤ 0.1 ms) and spatial (∼1 cm) resolution has been developed for a variety of physics topics studies in the EAST tokamak plasma. The fast edge electron temperature profile (approximately from r/a∼ 0.6 to the scrape-off layer) is investigated using ME-SXR diagnostic system. The data process was performed by the ideal ‘multi-foil’ technique, with no priori assumptions of plasma profiles. Reconstructed ME-SXR emissivity profiles for a variety of EAST experimental scenarios are presented here for the first time. The applications of the ME-SXR for study of the effects of resonant magnetic perturbation on edge localized modes and the first time neon radiating divertor experiment in EAST are also presented in this work. It has been found that neon impurity can suppress the 2/1 tearing mode and trigger a 3/1 MHD mode.

  11. Ions doped melanin nanoparticle as a multiple imaging agent.

    PubMed

    Ha, Shin-Woo; Cho, Hee-Sang; Yoon, Young Il; Jang, Moon-Sun; Hong, Kwan Soo; Hui, Emmanuel; Lee, Jung Hee; Yoon, Tae-Jong

    2017-10-10

    Multimodal nanomaterials are useful for providing enhanced diagnostic information simultaneously for a variety of in vivo imaging methods. According to our research findings, these multimodal nanomaterials offer promising applications for cancer therapy. Melanin nanoparticles can be used as a platform imaging material and they can be simply produced by complexation with various imaging active ions. They are capable of specifically targeting epidermal growth factor receptor (EGFR)-expressing cancer cells by being anchored with a specific antibody. Ion-doped melanin nanoparticles were found to have high bioavailability with long-term stability in solution, without any cytotoxicity in both in vitro and in vivo systems. By combining different imaging modalities with melanin particles, we can use the complexes to obtain faster diagnoses by computed tomography deep-body imaging and greater detailed pathological diagnostic information by magnetic resonance imaging. The ion-doped melanin nanoparticles also have applications for radio-diagnostic treatment and radio imaging-guided surgery, warranting further proof of concept experimental.

  12. Physics and Engineering Design of the ITER Electron Cyclotron Emission Diagnostic

    NASA Astrophysics Data System (ADS)

    Rowan, W. L.; Austin, M. E.; Houshmandyar, S.; Phillips, P. E.; Beno, J. H.; Ouroua, A.; Weeks, D. A.; Hubbard, A. E.; Stillerman, J. A.; Feder, R. E.; Khodak, A.; Taylor, G.; Pandya, H. K.; Danani, S.; Kumar, R.

    2015-11-01

    Electron temperature (Te) measurements and consequent electron thermal transport inferences will be critical to the non-active phases of ITER operation and will take on added importance during the alpha heating phase. Here, we describe our design for the diagnostic that will measure spatial and temporal profiles of Te using electron cyclotron emission (ECE). Other measurement capability includes high frequency instabilities (e.g. ELMs, NTMs, and TAEs). Since results from TFTR and JET suggest that Thomson Scattering and ECE differ at high Te due to driven non-Maxwellian distributions, non-thermal features of the ITER electron distribution must be documented. The ITER environment presents other challenges including space limitations, vacuum requirements, and very high-neutron-fluence. Plasma control in ITER will require real-time Te. The diagnosic design that evolved from these sometimes-conflicting needs and requirements will be described component by component with special emphasis on the integration to form a single effective diagnostic system. Supported by PPPL/US-DA via subcontract S013464-C to UT Austin.

  13. Advances in the understanding and clinical management of mastocytosis and clonal mast cell activation syndromes

    PubMed Central

    2016-01-01

    Clonal mast cell activation syndromes and indolent systemic mastocytosis without skin involvement are two emerging entities that sometimes might be clinically difficult to distinguish, and they involve a great challenge for the physician from both a diagnostic and a therapeutic point of view. Furthermore, final diagnosis of both entities requires a bone marrow study; it is recommended that this be done in reference centers. In this article, we address the current consensus and guidelines for the suspicion, diagnosis, classification, treatment, and management of these two entities. PMID:27909577

  14. Advances in the understanding and clinical management of mastocytosis and clonal mast cell activation syndromes.

    PubMed

    González-de-Olano, David; Matito, Almudena; Orfao, Alberto; Escribano, Luis

    2016-01-01

    Clonal mast cell activation syndromes and indolent systemic mastocytosis without skin involvement are two emerging entities that sometimes might be clinically difficult to distinguish, and they involve a great challenge for the physician from both a diagnostic and a therapeutic point of view. Furthermore, final diagnosis of both entities requires a bone marrow study; it is recommended that this be done in reference centers. In this article, we address the current consensus and guidelines for the suspicion, diagnosis, classification, treatment, and management of these two entities.

  15. The experience of the FERMI@Elettra photon beam transport and diagnostics system (PADReS) during three years of continuous support of machine and user experiments: achievements, lessons learned, and future upgrades

    NASA Astrophysics Data System (ADS)

    Zangrando, Marco; Fava, Claudio; Gerusina, Simone; Gobessi, Riccardo; Mahne, Nicola; Mazzucco, Eric; Raimondi, Lorenzo; Rumiz, Luca; Svetina, Cristian

    2014-09-01

    The FERMI FEL facility has begun delivering photons in 2011, becoming in late 2012 the first seeded facility open to external users worldwide. Since then, several tens of experiments have been carried out on the three operative endstations LDM, DiProI, and EIS-TIMEX. Starting from the commissioning phase, the transport and diagnostics system (PADReS) has been continuously developed and upgraded, becoming the indispensable interface between the machine and the experimental chambers. Moreover, PADReS itself has served as an active player for several machine studies as well as for various state-of-the-art experiments. In particular, some elements of PADReS have become key features to perform cutting edge experiments: the online energy spectrometer, the active optics refocusing systems, the split and delay line, and so on. For each of them the peculiar advantages will be described showing the actual implementation in the experiments. The experience gathered so far in fulfilling the needs of both machine and experimental physicists will be discussed, with particular emphasis on the solutions adopted in different scenarios. Recurrent requests and major difficulties will be reported so to give a glimpse about the standard tasks to be solved when preparing new and demanding experiments. Finally, some ideas and near-future improvements will be presented and discussed.

  16. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    PubMed

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  17. Purified umbilical cord derived mesenchymal stem cell treatment in a case of systemic lupus erythematosus.

    PubMed

    Phillips, Christopher D; Wongsaisri, Pornpatcharin; Htut, Thein; Grossman, Terry

    2017-12-01

    Systemic lupus erythematosus (SLE) is a multiple organ system autoimmune disorder for which there is no known cure. We report a case of a young adult lady with SLE and Sjogren's with diagnostic and clinical resolution following purified umbilical cord derived mesenchymal stem cell (MSC) and globulin component protein macrophage activating factor (GcMAF) therapy in a combined multidisciplinary integrative medicine protocol. Our patient had complete reversal of all clinical and laboratory markers. We recommend a prospective randomized double blind study to assess the sustained efficacy of MSC and GcMAF in the treatment of autoimmune connective tissue diseases such as systemic lupus erythematosus.

  18. The impact of image storage organization on the effectiveness of PACS.

    PubMed

    Hindel, R

    1990-11-01

    Picture archiving communication system (PACS) requires efficient handling of large amounts of data. Mass storage systems are cost effective but slow, while very fast systems, like frame buffers and parallel transfer disks, are expensive. The image traffic can be divided into inbound traffic generated by diagnostic modalities and outbound traffic into workstations. At the contact points with medical professionals, the responses must be fast. Archiving, on the other hand, can employ slower but less expensive storage systems, provided that the primary activities are not impeded. This article illustrates a segmentation architecture meeting these requirements based on a clearly defined PACS concept.

  19. Comparison of the Effectiveness of Interactive Didactic Lecture Versus Online Simulation-Based CME Programs Directed at Improving the Diagnostic Capabilities of Primary Care Practitioners.

    PubMed

    McFadden, Pam; Crim, Andrew

    2016-01-01

    Diagnostic errors in primary care contribute to increased morbidity and mortality, and billions in costs each year. Improvements in the way practicing physicians are taught so as to optimally perform differential diagnosis can increase patient safety and lower the costs of care. This study represents a comparison of the effectiveness of two approaches to CME training directed at improving the primary care practitioner's diagnostic capabilities against seven common and important causes of joint pain. Using a convenience sampling methodology, one group of primary care practitioners was trained by a traditional live, expert-led, multimedia-based training activity supplemented with interactive practice opportunities and feedback (control group). The second group was trained online with a multimedia-based training activity supplemented with interactive practice opportunities and feedback delivered by an artificial intelligence-driven simulation/tutor (treatment group). Before their respective instructional intervention, there were no significant differences in the diagnostic performance of the two groups against a battery of case vignettes presenting with joint pain. Using the same battery of case vignettes to assess postintervention diagnostic performance, there was a slight but not statistically significant improvement in the control group's diagnostic accuracy (P = .13). The treatment group, however, demonstrated a significant improvement in accuracy (P < .02; Cohen d, effect size = 0.79). These data indicate that within the context of a CME activity, a significant improvement in diagnostic accuracy can be achieved by the use of a web-delivered, multimedia-based instructional activity supplemented by practice opportunities and feedback delivered by an artificial intelligence-driven simulation/tutor.

  20. A Model-Based Expert System for Space Power Distribution Diagnostics

    NASA Technical Reports Server (NTRS)

    Quinn, Todd M.; Schlegelmilch, Richard F.

    1994-01-01

    When engineers diagnose system failures, they often use models to confirm system operation. This concept has produced a class of advanced expert systems that perform model-based diagnosis. A model-based diagnostic expert system for the Space Station Freedom electrical power distribution test bed is currently being developed at the NASA Lewis Research Center. The objective of this expert system is to autonomously detect and isolate electrical fault conditions. Marple, a software package developed at TRW, provides a model-based environment utilizing constraint suspension. Originally, constraint suspension techniques were developed for digital systems. However, Marple provides the mechanisms for applying this approach to analog systems such as the test bed, as well. The expert system was developed using Marple and Lucid Common Lisp running on a Sun Sparc-2 workstation. The Marple modeling environment has proved to be a useful tool for investigating the various aspects of model-based diagnostics. This report describes work completed to date and lessons learned while employing model-based diagnostics using constraint suspension within an analog system.

  1. Propulsion IVHM Technology Experiment

    NASA Technical Reports Server (NTRS)

    Chicatelli, Amy K.; Maul, William A.; Fulton, Christopher E.

    2006-01-01

    The Propulsion IVHM Technology Experiment (PITEX) successfully demonstrated real-time fault detection and isolation of a virtual reusable launch vehicle (RLV) main propulsion system (MPS). Specifically, the PITEX research project developed and applied a model-based diagnostic system for the MPS of the X-34 RLV, a space-launch technology demonstrator. The demonstration was simulation-based using detailed models of the propulsion subsystem to generate nominal and failure scenarios during captive carry, which is the most safety-critical portion of the X-34 flight. Since no system-level testing of the X-34 Main Propulsion System (MPS) was performed, these simulated data were used to verify and validate the software system. Advanced diagnostic and signal processing algorithms were developed and tested in real time on flight-like hardware. In an attempt to expose potential performance problems, the PITEX diagnostic system was subjected to numerous realistic effects in the simulated data including noise, sensor resolution, command/valve talkback information, and nominal build variations. In all cases, the PITEX system performed as required. The research demonstrated potential benefits of model-based diagnostics, defined performance metrics required to evaluate the diagnostic system, and studied the impact of real-world challenges encountered when monitoring propulsion subsystems.

  2. Improving the Army’s Next Effort in Technology Forecasting

    DTIC Science & Technology

    2010-09-01

    Health Maintenance— ability to make the robotic system more robust and to provide maintenance capabilities for self -monitoring, diagnostics, and...exhibit a verity of responses, including self -sensing and self - healing activities.43 A team of chemists and materials scientists led by the Moore...ultimately lead to i) applications in vehicles, including self -repairing armor, rubber , and coatings resistant to chemical agents, ii) aerospace

  3. Freshwater Cyanobacteria (Blue-Green Algae) Toxins: Isolation and Characterization

    DTIC Science & Technology

    1985-10-01

    Another study involves detailing the enzyme kinetics and membrane ion effects of a new anticholinesterase compound. 4) Collaborative studies to...poisoned with Microcystis and may have diagnostic significance in differentiating algal poisoning from other plant hepatotoxicities. These sheep... activation of the toxin by the liver enzyme systems, but to date ao one has investigated this possibility. Female mice were slightly more sensitive to

  4. Perceived Time Progression and Vigilance: Implications for Workload, Stress, and Cerebral Hemodynamics

    DTIC Science & Technology

    2013-04-01

    and maintaining the data needed , and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other...diagnostics indicate the need for immediate action (Sheridan, 1970, 1980). Consequently, vigilance has a critical impact in a wide range of automated...activating system) needed for continued alertness. Consequently, lethargy increases in observers and signal detection is reduced. However, recent findings

  5. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  6. The diagnostic value of a new fecal marker, matrix metalloprotease-9, in different types of inflammatory bowel diseases.

    PubMed

    Farkas, Klaudia; Saródi, Zoltán; Bálint, Anita; Földesi, Imre; Tiszlavicz, László; Szűcs, Mónika; Nyári, Tibor; Tajti, János; Nagy, Ferenc; Szepes, Zoltán; Bor, Renáta; Annaházi, Anita; Róka, Richárd; Molnár, Tamás

    2015-03-01

    Only limited data are available regarding the diagnostic accuracy of fecal matrix metalloprotease-9 [MMP-9] for inflammatory bowel disease [IBD]. The aims of our study were to assess the diagnostic accuracy of fecal MMP-9 in patients with active Crohn's disease [CD], ulcerative colitis [UC], and pouchitis, and to compare the diagnostic accuracy of fecal MMP-9 and fecal calprotectin [CP] in IBD. Stool and blood samples were collected in 50 CD, 54 UC, and 34 ileal pouch-anal anastomosis patients before control endoscopies were performed. Biopsies were taken for histologic purposes. The activities of CD, UC, and pouchitis were defined with the use of clinical, endoscopic, and histologic activity scores. Fecal CP and MMP-9 levels were quantified by enzyme-linked immunosorbent assay. Active CD, UC, and pouchitis were detected in 38%, 54%, and 29% of the patients, respectively. A significant correlation was revealed between fecal CP and the clinical activities of CD and UC, and between fecal CP and the endoscopic activity of UC and pouchitis. Fecal MMP-9 did not correlate with any of the activity indices of CD; however, strong associations were shown between fecal MMP-9 and clinical, endoscopic, and histologic activities of both UC and pouchitis. This is the first study assessing the diagnostic accuracy of MMP-9 in different types of IBD. Our results showed that fecal MMP-9 has high sensitivity in the detection of endoscopically active UC and pouchitis. These non-invasive methods help assess intestinal inflammation. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. Comparing diagnostic yield of a novel pan-enteric video capsule endoscope with ileocolonoscopy in patients with active Crohn's disease: a feasibility study.

    PubMed

    Leighton, Jonathan A; Helper, Debra J; Gralnek, Ian M; Dotan, Iris; Fernandez-Urien, Ignacio; Lahat, Adi; Malik, Pramod; Mullin, Gerard E; Rosa, Bruno

    2017-01-01

    Crohn's disease (CD) is typically diagnosed with ileocolonoscopy (IC); however, when inflammation is localized solely in the small bowel, visualization of the entire small-bowel mucosa can be challenging. The aim of this study was to compare the diagnostic yield of a pan-enteric video capsule endoscope (small-bowel colon [SBC] capsule) versus IC in patients with active CD. This was a prospective, multicenter study. Patients with known active CD and proven bowel luminal patency underwent a standardized colon cleansing protocol followed by ingestion of the capsule. After passage of the capsule, IC was performed and recorded. Lesions indicative of active CD were assessed. One hundred fourteen subjects were screened; 66 subjects completed both endoscopic procedures. The per-subject diagnostic yield rate for active CD lesions was 83.3% for SBC and 69.7% for IC (yield difference, 13.6%; 95% confidence interval [CI], 2.6%-24.7%); 65% of subjects had active CD lesions identified by both modalities. Of the 12 subjects who were positive for active CD by SBC only, 5 subjects were found to have active CD lesions in the terminal ileum. Three subjects were positive for active CD by IC only. Three hundred fifty-five classifying bowel segments were analyzed; the per-segment diagnostic yield rate was 40.6% for SBC and 32.7% for IC (yield difference 7.9%; 95% CI, 3.3%-12.4%). This preliminary study shows that the diagnostic yields for SBC might be higher than IC; however, the magnitude of difference between the two is difficult to estimate. Further study is needed to confirm these findings. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  8. Health-care district management information system plan: Review of operations analysis activities during calendar year 1975 and plan for continued research and analysis activities

    NASA Technical Reports Server (NTRS)

    Nielson, G. J.; Stevenson, W. G.

    1976-01-01

    Operations research activities developed to identify the information required to manage both the efficiency and effectiveness of the Veterans Administration (VA) health services as these services relate to individual patient care are reported. The clinical concerns and management functions that determine this information requirement are discussed conceptually. Investigations of existing VA data for useful management information are recorded, and a diagnostic index is provided. The age-specific characteristics of diseases and lengths of stay are explored, and recommendations for future analysis activities are articulated. The effect of the introduction of new technology to health care is also discussed.

  9. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  10. TFTR diagnostic control and data acquisition system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  11. Data mining approach to model the diagnostic service management.

    PubMed

    Lee, Sun-Mi; Lee, Ae-Kyung; Park, Il-Su

    2006-01-01

    Korea has National Health Insurance Program operated by the government-owned National Health Insurance Corporation, and diagnostic services are provided every two year for the insured and their family members. Developing a customer relationship management (CRM) system using data mining technology would be useful to improve the performance of diagnostic service programs. Under these circumstances, this study developed a model for diagnostic service management taking into account the characteristics of subjects using a data mining approach. This study could be further used to develop an automated CRM system contributing to the increase in the rate of receiving diagnostic services.

  12. Diagnostic quality of 50 and 100 µm computed radiography compared with screen–film mammography in operative breast specimens

    PubMed Central

    Pagliari, C M; Hoang, T; Reddy, M; Wilkinson, L S; Poloniecki, J D; Given-Wilson, R M

    2012-01-01

    Objective To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens. Methods Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925). Results For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5). Conclusion In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100. PMID:22096218

  13. What Makes Patient Navigation Most Effective: Defining Useful Tasks and Networks.

    PubMed

    Gunn, Christine; Battaglia, Tracy A; Parker, Victoria A; Clark, Jack A; Paskett, Electra D; Calhoun, Elizabeth; Snyder, Frederick R; Bergling, Emily; Freund, Karen M

    2017-01-01

    Given the momentum in adopting patient navigation into cancer care, there is a need to understand the contribution of specific navigator activities to improved clinical outcomes. A mixed-methods study combined direct observations of patient navigators within the Patient Navigation Research Program and outcome data from the trial. We correlated the frequency of navigator tasks with the outcome of rate of diagnostic resolution within 365 days among patients who received the intervention relative to controls. A focused content analysis examined those tasks with the strongest correlations between navigator tasks and patient outcomes. Navigating directly with specific patients (r = 0.679), working with clinical providers to facilitate patient care (r = 0.643), and performing tasks not directly related to their diagnostic evaluation for patients were positively associated with more timely diagnosis (r = 0.714). Using medical records for non-navigation tasks had a negative association (r = -0.643). Content analysis revealed service provision directed at specific patients improved care while systems-focused activities did not.

  14. Development and use of culture systems to modulate specific cell responses

    NASA Astrophysics Data System (ADS)

    Martin, Yves

    Culture surfaces that induce specific localized cell responses are required to achieve tissue-like cell growth in three-dimensional (3D) environments, as well as to develop more efficient cell-based diagnostic techniques, noticeably when working with fragile cells such as stem cells or platelets. As such, Chapter 1 of this thesis work is devoted to the review of 3D cell-material interactions in vitro and the corresponding existing culture systems available to achieve in vivo-like cell responses. More adequate 3D culture systems will need to be developed to mimic several characteristics of in vivo environments, including lowered non-specific cell-material interactions and localized biochemical signaling. The experimental work in this thesis is based on the hypothesis that well-studied and optimized surface treatments will be able to lower non-specific cell-material interactions and allow local chemical modification in order to achieve specific localized cell-material interactions for different applications. As such, in Chapter 2 and Chapter 3 of this thesis, surface treatments were developed using plasma polymerization and covalent immobilization of a low-fouling polymer (i.e., poly(ethylene glycol)) and characterized and optimized using a large number of techniques including atomic force microscopy, quartz crystal microbalance, surface plasmon resonance, x-ray photoelectron spectroscopy and fluorescence-based techniques. The main plasma polymerization parameter important for surface chemical content, specifically nitrogen to carbon content, was identified as being glow discharge power, while reaction time and power determined plasma film thickness. Moreover, plasma films were shown to be stable in aqueous environments. Covalently-bound poly(ethylene glycol) (PEG) layers physicochemical and mechanical properties are dependent on fabrication methods. Polymer concentration in solution is an important indicator of final layer properties, and use of a theta solvent induces complex aggregation phenomena in solution yielding layers with widely different properties. Chemically available primary amine groups are also shown to be present, paving the way for the immobilization of bio-active molecules. An application of low-fouling locally modified surfaces is given in Chapter 4 by the development of a novel diagnostic surface to evaluate platelet activation which is until now very difficult as platelets are readily activated by in vitro manipulations. Significant results from volunteer donors indicate that this diagnostic instrument has the potential to allow the rapid estimation of platelet activation levels in whole blood.

  15. The US Navy’s Helicopter Integrated Diagnostics System (HIDS) Program: Power Drive Train Crack Detection Diagnostics and Prognostics Life Usage Monitoring and Damage Tolerance; Techniques, Methodologies, and Experiences

    DTIC Science & Technology

    2000-02-01

    HIDS] Program: Power Drive Train Crack Detection Diagnostics and Prognostics ife Usage Monitoring and Damage Tolerance; Techniques, Methodologies, and...and Prognostics , Life Usage Monitoring , and Damage Tolerance; Techniques, Methodologies, and Experiences Andrew Hess Harrison Chin William Hardman...continuing program and deployed engine monitoring systems in fixed to evaluate helicopter diagnostic, prognostic , and wing aircraft, notably on the A

  16. Ultra-Compact Neuroprocessor for Automotive Diagnostic and Control

    NASA Technical Reports Server (NTRS)

    Tawel, R.; Aranki, N.; Feldkamp, L. A.; Marko, K. A.

    1998-01-01

    Demands on the performance of vehicle control and diagnostic systems are steadily increasing as a consequence of stiff global competition and government mandates. In the United States, light trucks and passenger cars are required both to meet strict emission standards and to perform continuous diagnostics of all emissions systems operating in the vehicle.

  17. Diagnoses and Presenting Symptoms in an Infant Psychiatry Clinic: Comparison of Two Diagnostic Systems.

    ERIC Educational Resources Information Center

    Frankel, Karen A.; Boyum, Lisa A.; Harmon, Robert J.

    2004-01-01

    Objective: To present data from a general infant psychiatry clinic, including range and frequency of presenting symptoms, relationship between symptoms and diagnoses, and comparison of two diagnostic systems, DSM-IV and Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood (DC: 0-3). Method: A…

  18. Differences in diagnostic activity in general practice and findings for individuals invited to the danish screening programme for colorectal cancer: a population-based cohort study.

    PubMed

    Juul, Jakob Søgaard; Andersen, Berit; Laurberg, Søren; Carlsen, Anders Helles; Olesen, Frede; Vedsted, Peter

    2018-06-22

    To investigate the diagnostic activity in general practice and the cumulative incidence of colorectal cancer (CRC) in individuals invited to the Danish national screening programme for CRC. A historical population-based cohort study. The Danish CRC screening programme and general practice. The 376,198 individuals invited to the Danish CRC screening programme from 1 March to 31 December 2014. The diagnostic activity (consultations and haemoglobin measures) in general practice in the year preceding the screening invitation and the cumulated incidence of CRC in the year following the screening invitation. Screening participants had significantly higher diagnostic activity than non-participants. Individuals with a positive faecal immunochemical test (FIT) had higher diagnostic activity compared to individuals with a negative FIT, and a small increase in the months leading up to the invitation. Individuals with a screen-detected CRC had lower diagnostic activity than individuals with no CRC. In total, 308 (25.3%) of CRCs diagnosed in the invited population were diagnosed outside the screening programme. Non-participants with CRC more often had low socio-economic status, high comorbidity and stage IV CRC than participants with CRC. There was a tendency that participants and those with a positive FIT had a higher diagnostic activity the year before the screening. This was not seen for those with CRC detected through screening. CRC must still be diagnosed in general practice in the invited population and non-participants are of special interest as they have higher risk of late stage CRC. Key Points Current awareness:Individuals with colorectal cancer (CRC) in screening may be symptomatic and CRC may still occur outside screening in the invited population. Most important points:The majority of individuals with CRC in screening cannot be expected to be diagnosed on symptomatic presentation in general practice GPs have to be aware that CRC still occurs outside screening in the invited population Non-participants with CRC are often deprived and have late stage CRC.

  19. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  20. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  1. Changes in the biological activity of chestnut soils upon the long-term application of fertilizers in a rotation with oil-bearing crops

    NASA Astrophysics Data System (ADS)

    Eleshev, R. E.; Bakenova, Z. B.

    2012-11-01

    Experimental studies showed that irrigated chestnut soils on the piedmont of the Zailiiskiy Alatau Range are characterized by the moderate activity of the hydrolytic and redox enzymes. The use of these soils in the crop rotation system increases the hydrolytic activity of the enzymes (invertase, urease, and ATP synthase) by 30% in comparison with the monoculture; at the same time, it does not have a significant impact on the changes in the biological activity of the redox enzymes (catalase and dehydrogenase). The hydrolytic activity of the soils is activated to a greater extent in the crop rotation and in the monoculture against the background application of organic fertilizers. In this case, the recommended rates of mineral fertilizers do not inhibit the activity of the hydrolytic and redox enzymes. An increase in the hydrolytic activity of the enzymes directly affects the yield of oilseed flax. Therefore, indices of the hydrolytic activity of soils can be used as a test for the diagnostics of the efficiency of fertilizers both in crop rotation and monoculture systems.

  2. Indian Test Facility (INTF) and its updates

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, M.; Chakraborty, A.; Rotti, C.; Joshi, J.; Patel, H.; Yadav, A.; Shah, S.; Tyagi, H.; Parmar, D.; Sudhir, Dass; Gahlaut, A.; Bansal, G.; Soni, J.; Pandya, K.; Pandey, R.; Yadav, R.; Nagaraju, M. V.; Mahesh, V.; Pillai, S.; Sharma, D.; Singh, D.; Bhuyan, M.; Mistry, H.; Parmar, K.; Patel, M.; Patel, K.; Prajapati, B.; Shishangiya, H.; Vishnudev, M.; Bhagora, J.

    2017-04-01

    To characterize ITER Diagnostic Neutral Beam (DNB) system with full specification and to support IPR’s negative ion beam based neutral beam injector (NBI) system development program, a R&D facility, named INTF is under commissioning phase. Implementation of a successful DNB at ITER requires several challenges need to be overcome. These issues are related to the negative ion production, its neutralization and corresponding neutral beam transport over the path lengths of ∼ 20.67 m to reach ITER plasma. DNB is a procurement package for INDIA, as an in-kind contribution to ITER. Since ITER is considered as a nuclear facility, minimum diagnostic systems, linked with safe operation of the machine are planned to be incorporated in it and so there is difficulty to characterize DNB after onsite commissioning. Therefore, the delivery of DNB to ITER will be benefited if DNB is operated and characterized prior to onsite commissioning. INTF has been envisaged to be operational with the large size ion source activities in the similar timeline, as with the SPIDER (RFX, Padova) facility. This paper describes some of the development updates of the facility.

  3. Progress towards implementation of ACT malaria case-management in public health facilities in the Republic of Sudan: a cluster-sample survey

    PubMed Central

    2012-01-01

    Background Effective malaria case-management based on artemisinin-based combination therapy (ACT) and parasitological diagnosis is a major pillar within the 2007-2012 National Malaria Strategic Plan in the Sudan. Three years after the launch of the strategy a health facility survey was undertaken to evaluate case-management practices and readiness of the health facilities and health workers to implement a new malaria case-management strategy. Methods A cross-sectional, cluster sample survey was undertaken at public health facilities in 15 states of Sudan. Data were collected using quality-of-care assessment methods. The main outcomes were the proportions of facilities with ACTs and malaria diagnostics; proportions of health workers exposed to malaria related health systems support activities; and composite and individual indicators of case-management practices for febrile outpatients stratified by age, availability of ACTs and diagnostics, use of malaria diagnostics, and test result. Results We evaluated 244 facilities, 294 health workers and 1,643 consultations for febrile outpatients (425 < 5 years and 1,218 ≥ 5 years). Health facility and health worker readiness was variable: chloroquine was available at only 5% of facilities, 73% stocked recommended artesunate and sulfadoxine/pyrimethamine (AS+SP), 51% had the capacity to perform parasitological diagnosis, 53% of health workers had received in-service training on ACTs, 24% were trained in the use of malaria Rapid Diagnostic Tests, and 19% had received a supervisory visit including malaria case-management. At all health facilities 46% of febrile patients were parasitologically tested and 35% of patients were both, tested and treated according to test result. At facilities where AS+SP and malaria diagnostics were available 66% of febrile patients were tested and 51% were both, tested and treated according to test result. Among test positive patients 64% were treated with AS+SP but 24% were treated with artemether monotherapy. Among test negative patients only 17% of patients were treated for malaria. The majority of ACT dispensing and counseling practices were suboptimal. Conclusions Five years following change of the policy from chloroquine to ACTs and 3 years before the end of the new malaria strategic plan chloroquine was successfully phased out from public facilities in Sudan, however, an important gap remained in the availability of ACTs, diagnostic capacities and coverage with malaria case-management activities. The national scale-up of diagnostics, using the findings of this survey as well as future qualitative research, should present an opportunity not only to expand existing testing capacities but also to implement effective support interventions to bridge the health systems gaps and support corrective case-management measures, including the discontinuation of artemether monotherapy treatment. PMID:22221821

  4. BioMEMS to bionanotechnology: state of the art in integrated biochips and future prospects

    NASA Astrophysics Data System (ADS)

    Gupta, Amit; Li, H.; Gomez, Rafael; Chang, W.-J.; Koo, Y. M.; Chang, H.; Andreadakis, G.; Akin, Demir; Bashir, Rashid

    2004-12-01

    Biomedical or Biological Micro-Electro-Mechanical- Systems (BioMEMS) have in recent years become increasingly prevalent and have found widespread use in a wide variety of applications such as diagnostics, therapeutics and tissue engineering. This paper reviews the interdisciplinary work performed in our group in recent years to develop micro-integrated devices to characterize biological entities. We present the use of electrical and mechanically based phenomena to perform characterization and various functions needed for integrated biochips. One sub-system takes advantage of the dielectrophoretic effect to sort and concentrate bacterial cells and viruses within a micro-fluidic biochip. Another sub-system measures impedance changes produced by the metabolic activity of bacterial cells to determine their viability. A third sub-system is used to detect the mass of viruses as they bind to micro-mechanical sensors. The last sub-system described has been used to detect the charge on DNA molecules as it translocates through nanopore channels. These devices with an electronic or mechanical signal output can be very useful in producing practical systems for rapid detection and characterization of cells for a wide variety of applications in the food safety and health diagnostics industries. The paper will also briefly discuss future prospects of BioMEMS and its possible impact and on bionanotechnology.

  5. Diagnostic value of decoy receptor 3 combined with procalcitonin and soluble urokinase-type plasminogen activator receptor for sepsis.

    PubMed

    Zhao, Jing-Jing; Lou, Xiao-Li; Chen, Hong-Wei; Zhu, Feng-Ting; Hou, Yan-Qiang

    2018-01-01

    The levels of decoy receptor 3 (DcR3), soluble urokinase type plasminogen activator receptor (suPAR) and procalcitonin (PCT) are significantly increased in sepsis. We investigated the diagnostic value of DcR3 combined with suPAR and PCT in sepsis. Patients with sepsis, non-infectious systemic inflammatory response comprehensive syndrome (SIRS) and healthy controls were recruited according to the diagnostic standard. We measured DcR3, suPAR, PCT, interleukin-6 (IL-6) and C-reactive protein (CRP), and the diagnostic value was evaluated by receiver operating characteristics (ROC) curves. In our analysis, serum DcR3, suPAR and PCT levels of the sepsis group were significantly higher than those of the SIRS and control groups. However, IL-6, CRP and WBC showed no significant difference between the SIRS group and the sepsis group. The serum DcR3 level was positively correlated with the serum suPAR level ( r  = 0.37, p  = 0.0022) and PCT level ( r  = 0.37, p  = 0.0021). Using DcR3, suPAR and PCT to distinguish SIRS from sepsis, the area under the curve (AUC) values were 0.892, 0.778 and 0.692. When DcR3, suPAR and PCT combined were used for diagnosis of sepsis, the AUC was 0.933, at a cut-off point of 0.342. This combination improved the sensitivity and specificity of diagnosis of sepsis, suggesting that use of the combination of three indexes enhanced the efficiency of sepsis diagnosis.

  6. Rooftop package unit diagnostician

    DOEpatents

    Chassin, David P [Pasco, WA; Pratt, Robert G [Kennewick, WA; Reid, Larry Dean [Benton City, WA

    2004-08-17

    A diagnostic system for an HVAC system includes a number of sensors used to measure the operation of the HVAC system. Sensor readings are measured by timing the delay between when a strobe signal is sent to a sensor and when an interrupt signal from the sensor is received. A device driver used to measure the sensor readings stores the sensor readings in pseudo-character device files, which are universally accessible by different subsystems of the diagnostic system. Based on the readings from these sensors, this diagnostic system is able to determine the operational status of the HVAC system and if an economizer in the HVAC system is operating properly.

  7. Sparsely Ionizing Diagnostic and Natural Background Radiations are Likely Preventing Cancer and Other Genomic-Instability-Associated Diseases

    PubMed Central

    Scott, Bobby R.; Di Palma, Jennifer

    2007-01-01

    Routine diagnostic X-rays (e.g., chest X-rays, mammograms, computed tomography scans) and routine diagnostic nuclear medicine procedures using sparsely ionizing radiation forms (e.g., beta and gamma radiations) stimulate the removal of precancerous neo-plastically transformed and other genomically unstable cells from the body (medical radiation hormesis). The indicated radiation hormesis arises because radiation doses above an individual-specific stochastic threshold activate a system of cooperative protective processes that include high-fidelity DNA repair/apoptosis (presumed p53 related), an auxiliary apoptosis process (PAM process) that is presumed p53-independent, and stimulated immunity. These forms of induced protection are called adapted protection because they are associated with the radiation adaptive response. Diagnostic X-ray sources, other sources of sparsely ionizing radiation used in nuclear medicine diagnostic procedures, as well as radioisotope-labeled immunoglobulins could be used in conjunction with apopto-sis-sensitizing agents (e.g., the natural phenolic compound resveratrol) in curing existing cancer via low-dose fractionated or low-dose, low-dose-rate therapy (therapeutic radiation hormesis). Evidence is provided to support the existence of both therapeutic (curing existing cancer) and medical (cancer prevention) radiation hormesis. Evidence is also provided demonstrating that exposure to environmental sparsely ionizing radiations, such as gamma rays, protect from cancer occurrence and the occurrence of other diseases via inducing adapted protection (environmental radiation hormesis). PMID:18648608

  8. Research and development studies for MHD/coal power flow train components. Part II. Diagnostics and instrumentation MHD channel combutor. Progres report. [Flow calculations for combustors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bloom, M.H.; Lederman, S.; Sforza, P.

    1980-01-01

    This is Part II of the Technical Progress Report on Tasks II-IV of the subject contract. It deals sequentially with Diagnostics and Instrumentation, the MHD Channel and the Combustor. During this period, a significant effort has gone into establishing a schematic design of a laser diagnostic system which can be applied to the flow-train of the MHD system, and to acquiring, assembling and shaking down a laboratory set-up upon which a prototype can be based. With further reference to the MHD Channel, a model analysis has been initiated of the two-dimensional MHD boundary layer between two electrodes in the limitmore » of small magnetic Reynolds numbers with negligible effect of the flow on the applied magnetic field. An objective of this model study is the assessment of variations in initial conditions on the boundary layer behavior. Finally, the problem of combustion modeling has been studied on an initial basis. The open reports on this subject depict a high degree of empiricism, centering attention on global behavior mainly. A quasi-one-dimensional model code has been set-up to check some of the existing estimates. Also a code for equilibrium combustion has been activated.« less

  9. Diagnostic X-ray sources-present and future

    NASA Astrophysics Data System (ADS)

    Behling, Rolf; Grüner, Florian

    2018-01-01

    This paper compares very different physical principles of X-ray production to spur ideation. Since more than 120 years, bremsstrahlung from X-ray tubes has been the workhorse of medical diagnostics. Generated by X-ray segments comprised of X-ray tubes and high-voltage generators in the various medical systems, X-ray photons in the spectral range between about 16 keV and 150 keV deliver information about anatomy and function of human patients and in pre-clinical animal studies. Despite of strides to employ the wave nature of X-rays as phase sensitive means, commercial diagnostic X-ray systems available until the time of writing still rely exclusively on measuring the attenuation and scattering of X-rays by matter. Significant activities in research aim at building highly brilliant short pulse X-ray sources, based on e.g. synchrotron radiation, free electron lasers and/or laser wake-field acceleration of electrons followed by wiggling with magnetic structures or Thomson scattering in bunches of light. While both approaches, non-brilliant and brilliant sources, have different scope of application, we speculate that a combination may expand the efficacy in medical application. At this point, however, severe technical and commercial difficulties hinder closing this gap. This article may inspire further development and spark innovation in this important field.

  10. An Artificial Intelligence Approach for Gears Diagnostics in AUVs

    PubMed Central

    Marichal, Graciliano Nicolás; Del Castillo, María Lourdes; López, Jesús; Padrón, Isidro; Artés, Mariano

    2016-01-01

    In this paper, an intelligent scheme for detecting incipient defects in spur gears is presented. In fact, the study has been undertaken to determine these defects in a single propeller system of a small-sized unmanned helicopter. It is important to remark that although the study focused on this particular system, the obtained results could be extended to other systems known as AUVs (Autonomous Unmanned Vehicles), where the usage of polymer gears in the vehicle transmission is frequent. Few studies have been carried out on these kinds of gears. In this paper, an experimental platform has been adapted for the study and several samples have been prepared. Moreover, several vibration signals have been measured and their time-frequency characteristics have been taken as inputs to the diagnostic system. In fact, a diagnostic system based on an artificial intelligence strategy has been devised. Furthermore, techniques based on several paradigms of the Artificial Intelligence (Neural Networks, Fuzzy systems and Genetic Algorithms) have been applied altogether in order to design an efficient fault diagnostic system. A hybrid Genetic Neuro-Fuzzy system has been developed, where it is possible, at the final stage of the learning process, to express the fault diagnostic system as a set of fuzzy rules. Several trials have been carried out and satisfactory results have been achieved. PMID:27077868

  11. Intelligent Data Visualization for Cross-Checking Spacecraft System Diagnosis

    NASA Technical Reports Server (NTRS)

    Ong, James C.; Remolina, Emilio; Breeden, David; Stroozas, Brett A.; Mohammed, John L.

    2012-01-01

    Any reasoning system is fallible, so crew members and flight controllers must be able to cross-check automated diagnoses of spacecraft or habitat problems by considering alternate diagnoses and analyzing related evidence. Cross-checking improves diagnostic accuracy because people can apply information processing heuristics, pattern recognition techniques, and reasoning methods that the automated diagnostic system may not possess. Over time, cross-checking also enables crew members to become comfortable with how the diagnostic reasoning system performs, so the system can earn the crew s trust. We developed intelligent data visualization software that helps users cross-check automated diagnoses of system faults more effectively. The user interface displays scrollable arrays of timelines and time-series graphs, which are tightly integrated with an interactive, color-coded system schematic to show important spatial-temporal data patterns. Signal processing and rule-based diagnostic reasoning automatically identify alternate hypotheses and data patterns that support or rebut the original and alternate diagnoses. A color-coded matrix display summarizes the supporting or rebutting evidence for each diagnosis, and a drill-down capability enables crew members to quickly view graphs and timelines of the underlying data. This system demonstrates that modest amounts of diagnostic reasoning, combined with interactive, information-dense data visualizations, can accelerate system diagnosis and cross-checking.

  12. An Artificial Intelligence Approach for Gears Diagnostics in AUVs.

    PubMed

    Marichal, Graciliano Nicolás; Del Castillo, María Lourdes; López, Jesús; Padrón, Isidro; Artés, Mariano

    2016-04-12

    In this paper, an intelligent scheme for detecting incipient defects in spur gears is presented. In fact, the study has been undertaken to determine these defects in a single propeller system of a small-sized unmanned helicopter. It is important to remark that although the study focused on this particular system, the obtained results could be extended to other systems known as AUVs (Autonomous Unmanned Vehicles), where the usage of polymer gears in the vehicle transmission is frequent. Few studies have been carried out on these kinds of gears. In this paper, an experimental platform has been adapted for the study and several samples have been prepared. Moreover, several vibration signals have been measured and their time-frequency characteristics have been taken as inputs to the diagnostic system. In fact, a diagnostic system based on an artificial intelligence strategy has been devised. Furthermore, techniques based on several paradigms of the Artificial Intelligence (Neural Networks, Fuzzy systems and Genetic Algorithms) have been applied altogether in order to design an efficient fault diagnostic system. A hybrid Genetic Neuro-Fuzzy system has been developed, where it is possible, at the final stage of the learning process, to express the fault diagnostic system as a set of fuzzy rules. Several trials have been carried out and satisfactory results have been achieved.

  13. Diagnostic Studies With GLA Fields

    NASA Technical Reports Server (NTRS)

    Salstein, David A.

    1997-01-01

    Assessments of the NASA Goddard Earth Observing System-1 Data Assimilation System (GEOS-1 DAS) regarding heating rates, energetics and angular momentum quantities were made. These diagnostics can be viewed as measures of climate variability. Comparisons with the NOAA/NCEP reanalysis system of momentum and energetics diagnostics are included. Water vapor and angular momentum are diagnosed in many models, including those of NASA, as part of the Atmospheric Model Intercomparison Project. Relevant preprints are included herein.

  14. Advances in the FTU collective Thomson scattering system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bin, W., E-mail: wbin@ifp.cnr.it; Bruschi, A.; Grosso, G.

    The new collective Thomson scattering diagnostic installed on the Frascati Tokamak Upgrade device started its first operations in 2014. The ongoing experiments investigate the presence of signals synchronous with rotating tearing mode islands, possibly due to parametric decay processes, and phenomena affecting electron cyclotron beam absorption or scattering measurements. The radiometric system, diagnostic layout, and data acquisition system were improved accordingly. The present status and near-term developments of the diagnostic are presented.

  15. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    NASA Astrophysics Data System (ADS)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  16. Hemophagocytic syndrome as one of the main primary manifestations in acute systemic lupus erythematosus--case report and literature review.

    PubMed

    Carvalheiras, G; Anjo, D; Mendonça, T; Vasconcelos, C; Farinha, F

    2010-05-01

    Hemophagocytic syndrome is an unusual but fatal disorder characterized by pancytopenia and activation of macrophages. We describe one case of acute systemic lupus erythematosus with an unusual presentation of hemophagocytic syndrome not related to infection. The patient presented with pancytopenia related to increasing hemophagocytic activity of histiocytes in the bone marrow. Concomitant class IV World Health Organization lupus nephritis, serositis, high titer of antinuclear factor and positive test for anti-DNA antibody fitted the diagnostic criteria of systemic lupus erythematosus. She also presented with alveolar hemorrhage and lupus myocarditis. She underwent immunosuppressive therapy with recovery from the hemophagocytic syndrome. Therefore, diagnosis of acute lupus hemophagocytic syndrome was made. The clinical presentation, laboratory diagnosis, and management of the patient are discussed and the literature was reviewed and presented, with emphasis on a possible distinct lupus subset, which includes a more aggressive systemic disease with heart involvement.

  17. Feminist identity as a predictor of eating disorder diagnostic status.

    PubMed

    Green, Melinda A; Scott, Norman A; Riopel, Cori M; Skaggs, Anna K

    2008-06-01

    Passive Acceptance (PA) and Active Commitment (AC) subscales of the Feminist Identity Development Scale (FIDS) were examined as predictors of eating disorder diagnostic status as assessed by the Questionnaire for Eating Disorder Diagnoses (Q-EDD). Results of a hierarchical regression analysis revealed PA and AC scores were not statistically significant predictors of ED diagnostic status after controlling for diagnostic subtype. Results of a multiple regression analysis revealed FIDS as a statistically significant predictor of ED diagnostic status when failing to control for ED diagnostic subtype. Discrepancies suggest ED diagnostic subtype may serve as a moderator variable in the relationship between ED diagnostic status and FIDS. (c) 2008 Wiley Periodicals, Inc.

  18. Study of plasma convection and wall interactions in magnetic confinement systems

    NASA Astrophysics Data System (ADS)

    York, T. M.

    1986-06-01

    The subject contract research effort was initiated in September 1976 with two specific tasks: (1) to study the fundamental physics of confinement of an alternate concept (i.e., theta pinch based) devices; and (2) to study and to develop new diagnostic systems for use on major experiments at other locations in the country. There has been active collaboration with Los Alamos National Laboratory and Lawrence Livermore National Laboratory; there has been proposed collaboration with Princeton Plasma Physics Laboratory, Fusion Research Center at the University of Texas, and General Atomics.

  19. Clinical evaluation of multiple inflammation biomarkers for diagnosis and prognosis for patients with systemic inflammatory response syndrome.

    PubMed

    Reichsoellner, M; Raggam, R B; Wagner, J; Krause, R; Hoenigl, M

    2014-11-01

    A multiplexed biomarker bundle consisting of nine different inflammation markers was evaluated regarding their diagnostic and prognostic performances in 159 adult systemic inflammatory response syndrome (SIRS) patients enrolled at the emergency department. Fibronectin, interleukin-8 (IL-8), biotin, and neutrophil gelatinase-associated lipocalin (NGAL) were the most robust markers but were not superior to the already established markers IL-6, C-reactive protein (CRP), procalcitonin (PCT), and soluble urokinase plasminogen activator receptor (suPAR). Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  20. Intelligent monitoring and diagnosis systems for the Space Station Freedom ECLSS

    NASA Technical Reports Server (NTRS)

    Dewberry, Brandon S.; Carnes, James R.

    1991-01-01

    Specific activities in NASA's environmental control and life support system (ECLSS) advanced automation project that is designed to minimize the crew and ground manpower needed for operations are discussed. Various analyses and the development of intelligent software for the initial and evolutionary Space Station Freedom (SSF) ECLSS are described. The following are also discussed: (1) intelligent monitoring and diagnostics applications under development for the ECLSS domain; (2) integration into the MSFC ECLSS hardware testbed; and (3) an evolutionary path from the baseline ECLSS automation to the more advanced ECLSS automation processes.

  1. The rare and undiagnosed diseases diagnostic service - application of massively parallel sequencing in a state-wide clinical service.

    PubMed

    Baynam, Gareth; Pachter, Nicholas; McKenzie, Fiona; Townshend, Sharon; Slee, Jennie; Kiraly-Borri, Cathy; Vasudevan, Anand; Hawkins, Anne; Broley, Stephanie; Schofield, Lyn; Verhoef, Hedwig; Walker, Caroline E; Molster, Caron; Blackwell, Jenefer M; Jamieson, Sarra; Tang, Dave; Lassmann, Timo; Mina, Kym; Beilby, John; Davis, Mark; Laing, Nigel; Murphy, Lesley; Weeramanthri, Tarun; Dawkins, Hugh; Goldblatt, Jack

    2016-06-11

    The Rare and Undiagnosed Diseases Diagnostic Service (RUDDS) refers to a genomic diagnostic platform operating within the Western Australian Government clinical services delivered through Genetic Services of Western Australia (GSWA). GSWA has provided a state-wide service for clinical genetic care for 28 years and it serves a population of 2.5 million people across a geographical area of 2.5milion Km(2). Within this context, GSWA has established a clinically integrated genomic diagnostic platform in partnership with other public health system managers and service providers, including but not limited to the Office of Population Health Genomics, Diagnostic Genomics (PathWest Laboratories) and with executive level support from the Department of Health. Herein we describe report presents the components of this service that are most relevant to the heterogeneity of paediatric clinical genetic care. Briefly the platform : i) offers multiple options including non-genetic testing; monogenic and genomic (targeted in silico filtered and whole exome) analysis; and matchmaking; ii) is delivered in a patient-centric manner that is resonant with the patient journey, it has multiple points for entry, exit and re-entry to allow people access to information they can use, when they want to receive it; iii) is synchronous with precision phenotyping methods; iv) captures new knowledge, including multiple expert review; v) is integrated with current translational genomic research activities and best practice; and vi) is designed for flexibility for interactive generation of, and integration with, clinical research for diagnostics, community engagement, policy and models of care. The RUDDS has been established as part of routine clinical genetic services and is thus sustainable, equitably managed and seeks to translate new knowledge into efficient diagnostics and improved health for the whole community.

  2. Microfluidics-Enabled Diagnostic Systems: Markets, Challenges, and Examples.

    PubMed

    Becker, Holger; Gärtner, Claudia

    2017-01-01

    Microfluidics has become an important tool for the commercial product development in diagnostics. This article will focus on current technical demands during the development process such as material and integration challenges. Furthermore, we present data on the diagnostics market as well as examples of microfluidics-enabled systems currently under commercial development or already on the market.

  3. Evaluation of Diagnostic Systems: The Selection of Students at Risk of Academic Difficulties

    ERIC Educational Resources Information Center

    Smolkowski, Keith; Cummings, Kelli D.

    2015-01-01

    Diagnostic tools can help schools more consistently and fairly match instructional resources to the needs of their students. To ensure the best educational outcome for each child, diagnostic decision-making systems seek to balance time, clarity, and accuracy. However, recent research notes that many educational decisions tend to be made using…

  4. Bayes' theorem application in the measure information diagnostic value assessment

    NASA Astrophysics Data System (ADS)

    Orzechowski, Piotr D.; Makal, Jaroslaw; Nazarkiewicz, Andrzej

    2006-03-01

    The paper presents Bayesian method application in the measure information diagnostic value assessment that is used in the computer-aided diagnosis system. The computer system described here has been created basing on the Bayesian Network and is used in Benign Prostatic Hyperplasia (BPH) diagnosis. The graphic diagnostic model enables to juxtapose experts' knowledge with data.

  5. Influence of environmental tobacco smoke on morphology and functions of cardiovascular system assessed using diagnostic imaging.

    PubMed

    Gać, Paweł; Poręba, Małgorzata; Pawlas, Krystyna; Sobieszczańska, Małgorzata; Poręba, Rafał

    Exposure to tobacco smoke is a significant problem of environmental medicine. Tobacco smoke contains over one thousand identified chemicals including numerous toxicants. Cardiovascular system diseases are the major cause of general mortality. The recent development of diagnostic imaging provided methods which enable faster and more precise diagnosis of numerous diseases, also those of cardiovascular system. This paper reviews the most significant scientific research concerning relationship between environmental exposure to tobacco smoke and the morphology and function of cardiovascular system carried out using diagnostic imaging methods, i.e. ultrasonography, angiography, computed tomography and magnetic resonance imaging. In the forthcoming future, the studies using current diagnostic imaging methods should contribute to the reliable documentation, followed by the wide-spreading knowledge of the harmful impact of the environmental tobacco smoke exposure on the cardiovascular system.

  6. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding.

    PubMed

    Wildgruber, Moritz; Wrede, Christian E; Zorger, Niels; Müller-Wille, René; Hamer, Okka W; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-03-01

    The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%-99%) and 29% (7 of 24 patients; 95% CI 12%-49%) of patients, respectively (p<0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%-63%) and 21% (5 of 24; 95% CI 7%-42%) of patients, respectively (p=0.06). Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB. Copyright © 2016. Published by Elsevier B.V.

  7. A vibroacoustic diagnostic system as an element improving road transport safety.

    PubMed

    Komorska, Iwona

    2013-01-01

    Mechanical defects of a vehicle driving system can be dangerous on the road. Diagnostic systems, which monitor operations of electric and electronic elements and devices of vehicles, are continuously developed and improved, while defects of mechanical systems are still not managed properly. This article proposes supplementing existing on-board diagnostics with a system of diagnosing selected defects to minimize their impact. It presents a method of diagnosing mechanical defects of the engine, gearbox and other elements of the driving system on the basis of a model of the vibration signal obtained adaptively. This method is suitable for engine valves, engine head gasket, main gearbox, joints, etc.

  8. ECRH and W7-X: An intriguing pair

    NASA Astrophysics Data System (ADS)

    Erckmann, V.; Braune, H.; Gantenbein, G.; Jelonnek, J.; Kasparek, W.; Laqua, H. P.; Lechte, C.; Marushchenko, N. B.; Michel, G.; Plaum, B.; Thumm, M.; Weissgerber, M.; Wolf, R.; W7-X ECRH Teams

    2014-02-01

    The construction of the W7-X basic machine is almost completed and the device is approaching the commissioning phase. W7-X operation will be supported by ECRH working at 140 GHz in 2nd harmonic X- or O-mode with 10 MW cw power. Presently the activities at W7-X concentrate on the implementation of wall-armour, in-vessel components and diagnostics. The ECRH-system is in stand by with 5 out of 10 gyrotrons operational. The status of both, the W7-X device and the ECRH system is reported. Further R&D activities concentrate on extending the launching capability for sophisticated confinement investigations with remote steering launchers in a poloidal plane with weak magnetic field gradient.

  9. Miniature Biometric Sensor Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Terrier, Douglas; Clayton, Ronald; Hanson, Andrea; Cooper, Tommy; Downs, Meghan; Flint, Stephanie; Reyna, Baraquiel; Simon, Cory; Wilt, Grier

    2015-01-01

    Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

  10. Levelized cost-benefit analysis of proposed diagnostics for the Ammunition Transfer Arm of the US Army`s Future Armored Resupply Vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkinson, V.K.; Young, J.M.

    1995-07-01

    The US Army`s Project Manager, Advanced Field Artillery System/Future Armored Resupply Vehicle (PM-AFAS/FARV) is sponsoring the development of technologies that can be applied to the resupply vehicle for the Advanced Field Artillery System. The Engineering Technology Division of the Oak Ridge National Laboratory has proposed adding diagnostics/prognostics systems to four components of the Ammunition Transfer Arm of this vehicle, and a cost-benefit analysis was performed on the diagnostics/prognostics to show the potential savings that may be gained by incorporating these systems onto the vehicle. Possible savings could be in the form of reduced downtime, less unexpected or unnecessary maintenance, fewermore » regular maintenance checks. and/or tower collateral damage or loss. The diagnostics/prognostics systems are used to (1) help determine component problems, (2) determine the condition of the components, and (3) estimate the remaining life of the monitored components. The four components on the arm that are targeted for diagnostics/prognostics are (1) the electromechanical brakes, (2) the linear actuators, (3) the wheel/roller bearings, and (4) the conveyor drive system. These would be monitored using electrical signature analysis, vibration analysis, or a combination of both. Annual failure rates for the four components were obtained along with specifications for vehicle costs, crews, number of missions, etc. Accident scenarios based on component failures were postulated, and event trees for these scenarios were constructed to estimate the annual loss of the resupply vehicle, crew, arm. or mission aborts. A levelized cost-benefit analysis was then performed to examine the costs of such failures, both with and without some level of failure reduction due to the diagnostics/prognostics systems. Any savings resulting from using diagnostics/prognostics were calculated.« less

  11. Pragmatic ethical basis for radiation protection in diagnostic radiology.

    PubMed

    Malone, Jim; Zölzer, Friedo

    2016-01-01

    Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years. The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations. A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic imaging. This system has the potential to be robust and to reach conclusions that are in accord with contemporary medical, social and ethical thinking. The system is not intended to replace the ICRP principles. Rather, it is intended as a well-informed interim approach that will help judge and analyse situations that arouse ethical concerns in radiology. Six scenarios illustrate the practicality of the value system in alerting one to possible deficits in practice. Five widely recognized values and the basis for them are identified to support the contemporary practice of diagnostic radiology. These are essential to complement the widely used ICRP principles pending further development in the area.

  12. [Stress and autonomic dysregulation in patients with fibromyalgia syndrome].

    PubMed

    Friederich, H-C; Schellberg, D; Mueller, K; Bieber, C; Zipfel, S; Eich, W

    2005-06-01

    The aim of the present study was to evaluate to what extent the orthostatic dysregulation of FMS patients can be attributed primarily to reduced baroreceptor-mediated activation of the sympathetic nervous system and whether a hyporeactive sympathetic nervous system can also be confirmed for mental stress. A total of 28 patients with primary FMS were examined and compared with 15 healthy subjects. Diagnostic investigations of the autonomic nervous system were based on measuring HRV in frequency range and assessing spontaneous baroreflex sensitivity (sBRS) under mental stress and passive orthostatism. Both under orthostatic and mental stress FMS patients exhibited reduced activation of the sympathetic nervous system as measured by the spectral power of HRV in the low-frequency range and the mean arterial blood pressure or heart rate. The present study provided no indications for dysregulation of sBRS. The results obtained confirm the hypothesis of a hyporeactive stress system in FMS patients for both peripherally and centrally mediated stimulation of the sympathetic nervous system.

  13. Recorded gonorrhoea rates in Denmark, 1900-2010: the impact of clinical testing activity and laboratory diagnostic procedures.

    PubMed

    Lind, Inga; Hoffmann, Steen

    2015-11-30

    Assessment of the relations between recorded gonorrhoea rates and clinical testing activity and disposable diagnostic tests. In Denmark, two sources of information on the epidemiology of gonorrhoea are available: (1) a mandatory clinical notification system (since 1867) comprising summary information about geographic distribution, season, age group and gender; in 1994, more detailed anonymous individualised epidemiological information was included; (2) a voluntary countrywide laboratory surveillance system for culture-confirmed cases (since 1957) comprising information about patient's age and gender, infected anatomical sites and medical setting attended. Both surveillance systems showed marked simultaneous changes in gonorrhoea rates, although periodically considerable under-reporting or under-diagnosing was demonstrated. The annual incidence of notified cases peaked in 1919 (474/100,000), in 1944 (583/100,000) and in 1972 (344/100,000). Since 1995, the incidence has been at a low endemic level (1.5-10/100,000) and the total male/female incidence ratios were from 3 to 7 times higher than previously recorded. Among approximately 2 million persons tested during 1974-1988 78,213 men and 63,143 women with culture-confirmed gonorrhoea were identified. During this period, pharyngeal sampling was performed in 36% of men and 25% of women with gonorrhoea; pharyngeal gonorrhoea was found in 10% and 16%, respectively; 40% and 30% of these patients had no concomitant urogenital gonorrhoea. Among men with gonorrhoea, 34% were sampled from the rectum; 9% had rectal gonorrhoea, among whom the rectum was the only infected site in 67%. Crucial factors for case finding are clinical sampling tradition and appropriate laboratory diagnostic facilities. When case finding is insufficient, a reservoir of asymptomatic rectal or pharyngeal gonorrhoea remains unrecognised. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Implementation of HIV and Tuberculosis Diagnostics: The Importance of Context

    PubMed Central

    Dominique, Joyelle K.; Ortiz-Osorno, Alberto A.; Fitzgibbon, Joseph; Gnanashanmugam, Devasena; Gilpin, Christopher; Tucker, Timothy; Peel, Sheila; Peter, Trevor; Kim, Peter; Smith, Steven

    2015-01-01

    Background. Novel diagnostics have been widely applied across human immunodeficiency virus (HIV) and tuberculosis prevention and treatment programs. To achieve the greatest impact, HIV and tuberculosis diagnostic programs must carefully plan and implement within the context of a specific healthcare system and the laboratory capacity. Methods. A workshop was convened in Cape Town in September 2014. Participants included experts from laboratory and clinical practices, officials from ministries of health, and representatives from industry. Results. The article summarizes best practices, challenges, and lessons learned from implementation experiences across sub-Saharan Africa for (1) building laboratory programs within the context of a healthcare system; (2) utilizing experience of clinicians and healthcare partners in planning and implementing the right diagnostic; and (3) evaluating the effects of new diagnostics on the healthcare system and on patient health outcomes. Conclusions. The successful implementation of HIV and tuberculosis diagnostics in resource-limited settings relies on careful consideration of each specific context. PMID:26409272

  15. A novel label-free fluorescence strategy for methyltransferase activity assay based on dsDNA-templated copper nanoparticles coupled with an endonuclease-assisted signal transduction system.

    PubMed

    Lai, Q Q; Liu, M D; Gu, C C; Nie, H G; Xu, X J; Li, Z H; Yang, Z; Huang, S M

    2016-02-21

    Evaluating DNA methyltransferase (MTase) activity has received considerable attention due to its significance in the fields of early cancer clinical diagnostics and drug discovery. Herein, we proposed a novel label-free fluorescence method for MTase activity assay by coupling double-stranded DNA (dsDNA)-templated copper nanoparticles (CuNPs) with an endonuclease-assisted signal transduction system. In this strategy, dsDNA molecules were first methylated by DNA adenine methylation (Dam) MTase and then cleaved by the methylation-sensitive restriction endonuclease DpnI. The cleaved DNA fragments could not act as efficient templates for the formation of fluorescent CuNPs and thus no fluorescence signal was produced. Under optimized experimental conditions, the developed strategy exhibited a sensitive fluorescence response to Dam MTase activity. This strategy was also demonstrated to provide an excellent platform to the inhibitor screening for Dam MTase. These results demonstrated the great potential for the practical applications of the proposed strategy for Dam MTase activity assay.

  16. Integrated failure detection and management for the Space Station Freedom external active thermal control system

    NASA Technical Reports Server (NTRS)

    Mesloh, Nick; Hill, Tim; Kosyk, Kathy

    1993-01-01

    This paper presents the integrated approach toward failure detection, isolation, and recovery/reconfiguration to be used for the Space Station Freedom External Active Thermal Control System (EATCS). The on-board and on-ground diagnostic capabilities of the EATCS are discussed. Time and safety critical features, as well as noncritical failures, and the detection coverage for each provided by existing capabilities are reviewed. The allocation of responsibility between on-board software and ground-based systems, to be shown during ground testing at the Johnson Space Center, is described. Failure isolation capabilities allocated to the ground include some functionality originally found on orbit but moved to the ground to reduce on-board resource requirements. Complex failures requiring the analysis of multiple external variables, such as environmental conditions, heat loads, or station attitude, are also allocated to ground personnel.

  17. Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

    NASA Technical Reports Server (NTRS)

    Milos, Frank S.; Karunaratne, K.; Arnold, Jim (Technical Monitor)

    2002-01-01

    Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

  18. Quantitation of 5-Methyltetrahydrofolate in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.

  19. Strategies for diagnosing leg oedema in primary care: a qualitative study of GPs' approaches.

    PubMed

    Diederich, Judith; Hartel, Simone; Baum, Erika; Bösner, Stefan

    2014-12-01

    The symptom leg oedema represents a broad range of possible underlying aetiologies. The background of leg oedema is multifactorial and usually the GP is the first contact point for patients presenting with this symptom. GPs rely on patient history and physical examination as their main diagnostic tools. To identify GPs' diagnostic approaches and heuristics in patients presenting with leg oedema. Interviews with 15 GPs (20-30 min) using a semi-structured interview-guideline were conducted. GPs described their individual diagnostic strategies concerning all patients presenting with leg oedema they had prospectively identified during the previous four weeks. Interviews were taped and transcribed verbatim. Qualitative analysis was conducted by two independent raters. GPs applied a variety of diagnostic approaches, which can be grouped in active and passive strategies. Active strategies comprised the use of decision rules and guidelines, Bayesian arguing, problem dichotomisation and discrepancy heuristics. Passive approaches included test of time, therapy as diagnosis, and taking patient assumptions into account. When dealing with leg oedema, GPs use prior information of individual patients in a specific way. There is a broad variety of diagnostic approaches that can be grouped in 'active' and 'passive' behaviour. Approaches mostly match with established diagnostic strategies in primary care.

  20. Development of a New Diagnostic System for Human Liver Diseases Based on Conventional Ultrasonic Diagnostic Equipment

    NASA Astrophysics Data System (ADS)

    Kikuchi, Tsuneo; Nakazawa, Toshihiro; Harada, Akimitsu; Sato, Hiroaki; Maruyama, Yukio; Sato, Sojun

    2001-05-01

    In this paper, the authors present the experimental results of using a quantitative ultrasonic diagnosis technique for human liver diseases using the fractal dimension (FD) of the shape of the power spectra (PS) of RF signals. We have developed an experimental system based on a conventional ultrasonic diagnostic system. As a result, we show that normal livers, fatty livers and liver cirrhosis can be identified using the FD values.

  1. System theory in medical diagnostic devices: an overview.

    PubMed

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  2. Space Shuttle main engine OPAD: The search for a hardware enhanced plume

    NASA Astrophysics Data System (ADS)

    Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.

    1993-11-01

    The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.

  3. Space Shuttle main engine OPAD: The search for a hardware enhanced plume

    NASA Technical Reports Server (NTRS)

    Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.

    1993-01-01

    The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.

  4. Adaptive control with an expert system based supervisory level. Thesis

    NASA Technical Reports Server (NTRS)

    Sullivan, Gerald A.

    1991-01-01

    Adaptive control is presently one of the methods available which may be used to control plants with poorly modelled dynamics or time varying dynamics. Although many variations of adaptive controllers exist, a common characteristic of all adaptive control schemes, is that input/output measurements from the plant are used to adjust a control law in an on-line fashion. Ideally the adjustment mechanism of the adaptive controller is able to learn enough about the dynamics of the plant from input/output measurements to effectively control the plant. In practice, problems such as measurement noise, controller saturation, and incorrect model order, to name a few, may prevent proper adjustment of the controller and poor performance or instability result. In this work we set out to avoid the inadequacies of procedurally implemented safety nets, by introducing a two level control scheme in which an expert system based 'supervisor' at the upper level provides all the safety net functions for an adaptive controller at the lower level. The expert system is based on a shell called IPEX, (Interactive Process EXpert), that we developed specifically for the diagnosis and treatment of dynamic systems. Some of the more important functions that the IPEX system provides are: (1) temporal reasoning; (2) planning of diagnostic activities; and (3) interactive diagnosis. Also, because knowledge and control logic are separate, the incorporation of new diagnostic and treatment knowledge is relatively simple. We note that the flexibility available in the system to express diagnostic and treatment knowledge, allows much greater functionality than could ever be reasonably expected from procedural implementations of safety nets. The remainder of this chapter is divided into three sections. In section 1.1 we give a detailed review of the literature in the area of supervisory systems for adaptive controllers. In particular, we describe the evolution of safety nets from simple ad hoc techniques, up to the use of expert systems for more advanced supervision capabilities.

  5. 21 CFR Appendix B to Subpart B of... - Scope of Product Coverage

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Transducer ITX—Transducer, Ultrasonic, Diagnostic Diagnostic X-Ray Imaging Devices (except mammographic x-ray systems): RA 892.1600 Angiographic X-Ray System IZI—System, X-Ray, Angiographic RA 892.1650 Image-Intensified Fluoroscopic X-Ray System MQB—Solid State X-Ray Imager (Flat Panel/Digital Imager) JAA—System, X...

  6. 21 CFR Appendix B to Subpart B of... - Scope of Product Coverage

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Transducer ITX—Transducer, Ultrasonic, Diagnostic Diagnostic X-Ray Imaging Devices (except mammographic x-ray systems): RA 892.1600 Angiographic X-Ray System IZI—System, X-Ray, Angiographic RA 892.1650 Image-Intensified Fluoroscopic X-Ray System MQB—Solid State X-Ray Imager (Flat Panel/Digital Imager) JAA—System, X...

  7. Rapid Pneumatic Transport of Radioactive Samples - RaPToRS

    NASA Astrophysics Data System (ADS)

    Padalino, S.; Barrios, M.; Sangster, C.

    2005-10-01

    Some ICF neutron activation diagnostics require quick retrieval of the activated sample. Minimizing retrieval times is particularly important when the half-life of the activated material is on the order of the transport time or the degree of radioactivity is close to the background counting level. These restrictions exist in current experiments performed at the Laboratory for Laser Energetics, thus motivating the development of the RaPToRS system. The system has been designed to minimize transportation time while requiring no human intervention during transport or counting. These factors will be important if the system is to be used at the NIF where radiological hazards will be present during post activation. The sample carrier is pneumatically transported via a 4 inch ID PVC pipe to a remote location in excess of 100 meters from the activation site at a speed of approximately 7 m/s. It arrives at an end station where it is dismounted robotically from the carrier and removed from its hermetic package. The sample is then placed by the robot in a counting station. This system is currently being developed to measure back-to-back gamma rays produced by positron annihilation which were emitted by activated graphite. Funded in part by the U.S. DOE under sub contract with LLE at the University of Rochester.

  8. Diagnostic Algorithm Benchmarking

    NASA Technical Reports Server (NTRS)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  9. Five systems of psychiatric classification for preschool children: do differences in validity, usefulness and reliability make for competitive or complimentary constellations?

    PubMed

    Postert, Christian; Averbeck-Holocher, Marlies; Beyer, Thomas; Müller, Jörg; Furniss, Tilman

    2009-03-01

    DSM-IV and ICD-10 have limitations in the diagnostic classification of psychiatric disorders at preschool age (0-5 years). The publication of the Diagnostic Classification 0-3 (DC:0-3) in 1994, its basically revised second edition (DC:0-3R) in 2005 and the Research Diagnostic Criteria-Preschool Age (RDC-PA) in 2004 have provided several modifications of these manuals. Taking into account the growing empirical evidence highlighting the need for a diagnostic classification system for psychiatric disorders in preschool children, the main categorical classification systems in preschool psychiatry will be presented and discussed. The paper will focus on issues of validity, usefulness and reliability in DSM-IV, ICD-10, RDC-PA, DC:0-3, and DC:0-3R. The reasons for including or excluding postulated psychiatric disorder categories for preschool children with variable degrees of empirical evidence into the different diagnostic systems will be discussed.

  10. Translational health economics: The key to accountable adoption of in vitro diagnostic technologies.

    PubMed

    Price, Christopher P; Wolstenholme, Jane; McGinley, Patrick; St John, Andrew

    2018-02-01

    Adoption of new technologies, including diagnostic tests, is often considered not to deliver the expected return on investment. The reasons for this poor link between expectation and outcome include lack of evidence, variation in use of the technology, and an inability of the health system to manage the balance between investment and disinvestment associated with the change in care pathway. The challenges lie in the complex nature of healthcare provision where the investment is likely to be made in the jurisdiction of one stakeholder while the benefits (as well as dis-benefits) accrue to the other stakeholders. A prime example is found in the field of laboratory medicine and the use of diagnostic tests. The current economic tools employed in healthcare are primarily used to make policy and strategic decisions, particularly across health systems, and in purchaser and provider domains. These tools primarily involve cost effectiveness and budget impact analyses, both of which have been applied in health technology assessment of diagnostic technologies. However, they lack the granularity to translate findings down to the financial management and operational decision making at the provider department level. We propose an approach to translational health economics based on information derived from service line management and time-driven activity-based costing, identifying the resource utilisation for each of the units involved in the delivery of a care pathway, before and after adoption of new technology. This will inform investment and disinvestment decisions, along with identifying where the benefits, and dis-benefits, can be achieved for all stakeholders.

  11. Integrating nursing diagnostic concepts into the medical entities dictionary using the ISO Reference Terminology Model for Nursing Diagnosis.

    PubMed

    Hwang, Jee-In; Cimino, James J; Bakken, Suzanne

    2003-01-01

    The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED. The authors dissected nursing diagnostic terms from two source terminologies (Home Health Care Classification and the Omaha System) into the semantic categories of the ISO model. Consistent with the ISO model, they selected Focus and Judgment as required semantic categories for creating intensional definitions of nursing diagnostic concepts in the MED. Because the MED does not include Focus and Judgment hierarchies, the authors developed them to define the nursing diagnostic concepts. The ISO model was sufficient for dissecting the source terminologies into atomic terms. The authors identified 162 unique focus concepts from the 266 nursing diagnosis terms for inclusion in the Focus hierarchy. For the Judgment hierarchy, the authors precoordinated Judgment and Potentiality instead of using Potentiality as a qualifier of Judgment as in the ISO model. Impairment and Alteration were the most frequently occurring judgments. Nursing care represents a large proportion of health care activities; thus, it is vital that terms used by nurses are integrated into concept-oriented terminologies that provide broad coverage for the domain of health care. This study supports the utility of the ISO Reference Terminology Model for Nursing Diagnoses as a facilitator for the integration process.

  12. Integrating Nursing Diagnostic Concepts into the Medical Entities Dictionary Using the ISO Reference Terminology Model for Nursing Diagnosis

    PubMed Central

    Hwang, Jee-In; Cimino, James J.; Bakken, Suzanne

    2003-01-01

    Objective: The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED. Design and Measurements: The authors dissected nursing diagnostic terms from two source terminologies (Home Health Care Classification and the Omaha System) into the semantic categories of the ISO model. Consistent with the ISO model, they selected Focus and Judgment as required semantic categories for creating intensional definitions of nursing diagnostic concepts in the MED. Because the MED does not include Focus and Judgment hierarchies, the authors developed them to define the nursing diagnostic concepts. Results: The ISO model was sufficient for dissecting the source terminologies into atomic terms. The authors identified 162 unique focus concepts from the 266 nursing diagnosis terms for inclusion in the Focus hierarchy. For the Judgment hierarchy, the authors precoordinated Judgment and Potentiality instead of using Potentiality as a qualifier of Judgment as in the ISO model. Impairment and Alteration were the most frequently occurring judgments. Conclusions: Nursing care represents a large proportion of health care activities; thus, it is vital that terms used by nurses are integrated into concept-oriented terminologies that provide broad coverage for the domain of health care. This study supports the utility of the ISO Reference Terminology Model for Nursing Diagnoses as a facilitator for the integration process. PMID:12668692

  13. Diagnosing cancer in primary care: results from the National Cancer Diagnosis Audit.

    PubMed

    Swann, Ruth; McPhail, Sean; Witt, Jana; Shand, Brian; Abel, Gary A; Hiom, Sara; Rashbass, Jem; Lyratzopoulos, Georgios; Rubin, Greg

    2018-01-01

    Continual improvements in diagnostic processes are needed to minimise the proportion of patients with cancer who experience diagnostic delays. Clinical audit is a means of achieving this. To characterise key aspects of the diagnostic process for cancer and to generate baseline measures for future re-audit. Clinical audit of cancer diagnosis in general practices in England. Information on patient and tumour characteristics held in the English National Cancer Registry was supplemented by information from GPs in participating practices. Data items included diagnostic timepoints, patient characteristics, and clinical management. Data were collected on 17 042 patients with a new diagnosis of cancer during 2014 from 439 practices. Participating practices were similar to non-participating ones, particularly regarding population age, urban/rural location, and practice-based patient experience measures. The median diagnostic interval for all patients was 40 days (interquartile range [IQR] 15-86 days). Most patients were referred promptly (median primary care interval 5 days [IQR 0-27 days]). Where GPs deemed diagnostic delays to have occurred (22% of cases), patient, clinician, or system factors were responsible in 26%, 28%, and 34% of instances, respectively. Safety netting was recorded for 44% of patients. At least one primary care-led investigation was carried out for 45% of patients. Most patients (76%) had at least one existing comorbid condition; 21% had three or more. The findings identify avenues for quality improvement activity and provide a baseline for future audit of the impact of 2015 National Institute for Health and Care Excellence guidance on management and referral of suspected cancer. © British Journal of General Practice 2018.

  14. A fuzzy logic intelligent diagnostic system for spacecraft integrated vehicle health management

    NASA Technical Reports Server (NTRS)

    Wu, G. Gordon

    1995-01-01

    Due to the complexity of future space missions and the large amount of data involved, greater autonomy in data processing is demanded for mission operations, training, and vehicle health management. In this paper, we develop a fuzzy logic intelligent diagnostic system to perform data reduction, data analysis, and fault diagnosis for spacecraft vehicle health management applications. The diagnostic system contains a data filter and an inference engine. The data filter is designed to intelligently select only the necessary data for analysis, while the inference engine is designed for failure detection, warning, and decision on corrective actions using fuzzy logic synthesis. Due to its adaptive nature and on-line learning ability, the diagnostic system is capable of dealing with environmental noise, uncertainties, conflict information, and sensor faults.

  15. THE INTERACTIVE AUTOMATIC SYNDROME DIAGNOSTIC PROGRAM OF DIGESTIVE SYSTEM DISEASES "ELECTRONIC POLICLINIC".

    PubMed

    Mishlanov, V Yu; Katkova, A V; Dugina, A A; Kuznetzova, V D; Tepanyan, A T; Zhygulev, A N

    The aim of the study was to estimate clinical efficiency of the interactive automatic program of digestive system diseases diagnostics "Electronic policlinic". Material was presented by 22 patients with different gastroenterological diseases (duodenal ulcer, chronical gastritis, chronical pancreatitis) and the comparative group consisted of 20 healthy people. The plan of the research included the interactive questionnaire using diagnostic module digestive system diseases of the digestive system of the automated program "Electronic policlinic" (Certificate No. 2012614202 from 12.05.12) posted on the Internet (http://klinikcity.ru). For the purpose of verification of diagnosis patients underwent fibrogastroduodenoscopy, ultrasound examination of abdominal cavity organs, CT scan, sigmoidoscopy, colonoscopy, barium enema. As the result of the study there were showed that interactive automated system was able to reveal 85,7% of patients with chronical gastritis, duodenal ulcer and chronical pancreatitis and 75% of patients with colonopathy. The specify of diagnostic procedure was 80% in the first case and 100% in the second. Prevalence of digestive system diseases basic symptoms was studied too. The conclusion of the study demonstrated interactive questionnaire good ability in preliminary digestive problem patient examination procedure for individual diagnostic plan making.

  16. A real-time diagnostic and performance monitor for UNIX. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Dong, Hongchao

    1992-01-01

    There are now over one million UNIX sites and the pace at which new installations are added is steadily increasing. Along with this increase, comes a need to develop simple efficient, effective and adaptable ways of simultaneously collecting real-time diagnostic and performance data. This need exists because distributed systems can give rise to complex failure situations that are often un-identifiable with single-machine diagnostic software. The simultaneous collection of error and performance data is also important for research in failure prediction and error/performance studies. This paper introduces a portable method to concurrently collect real-time diagnostic and performance data on a distributed UNIX system. The combined diagnostic/performance data collection is implemented on a distributed multi-computer system using SUN4's as servers. The approach uses existing UNIX system facilities to gather system dependability information such as error and crash reports. In addition, performance data such as CPU utilization, disk usage, I/O transfer rate and network contention is also collected. In the future, the collected data will be used to identify dependability bottlenecks and to analyze the impact of failures on system performance.

  17. 2007 Beyond SBIR Phase II: Bringing Technology Edge to the Warfighter

    DTIC Science & Technology

    2007-08-23

    Systems Trade-Off Analysis and Optimization Verification and Validation On-Board Diagnostics and Self - healing Security and Anti-Tampering Rapid...verification; Safety and reliability analysis of flight and mission critical systems On-Board Diagnostics and Self - Healing Model-based monitoring and... self - healing On-board diagnostics and self - healing ; Autonomic computing; Network intrusion detection and prevention Anti-Tampering and Trust

  18. GONADAL AND BONE MARROW DOSE IN MEDICAL DIAGNOSTIC RADIOLOGY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahmoud, K.A.; Mahfouz, M.M.; Mahmoud, M.E.

    1961-08-01

    Measurements were made of the active mean bone marrow, integral bone marrow, gonadal, and maximum skin doses from diagnostic x-ray procedures used in Cairo University Hospitals. The active mean marrow dose in cervical, dorsal, and lumbar spine diagnostic exposures were: found to be somewhat smaller than those reported by some western couatries. One of the most striking results of the survey was the relatively high values of the urinary tract cases investigated diagnostically; owing to the high incidence of urinary tract Schistosomiasis. The gonadal dose delivered to males and females was found to be almosi negligible for all diagnostic investigationsmore » of the spine, except for the lumbo-dorsal region which was within the range 50 to 500 mrads. It was also found that the gonadal dose was significant in investigations of the lower gastrointestinal tract, gall bladder, and urinary tract. (P.C.H.)« less

  19. Differentiating sepsis from non-infectious systemic inflammation based on microvesicle-bacteria aggregation

    NASA Astrophysics Data System (ADS)

    Herrmann, I. K.; Bertazzo, S.; O'Callaghan, D. J. P.; Schlegel, A. A.; Kallepitis, C.; Antcliffe, D. B.; Gordon, A. C.; Stevens, M. M.

    2015-08-01

    Sepsis is a severe medical condition and a leading cause of hospital mortality. Prompt diagnosis and early treatment has a significant, positive impact on patient outcome. However, sepsis is not always easy to diagnose, especially in critically ill patients. Here, we present a conceptionally new approach for the rapid diagnostic differentiation of sepsis from non-septic intensive care unit patients. Using advanced microscopy and spectroscopy techniques, we measure infection-specific changes in the activity of nano-sized cell-derived microvesicles to bind bacteria. We report on the use of a point-of-care-compatible microfluidic chip to measure microvesicle-bacteria aggregation and demonstrate rapid (<=1.5 hour) and reliable diagnostic differentiation of bacterial infection from non-infectious inflammation in a double-blind pilot study. Our study demonstrates the potential of microvesicle activities for sepsis diagnosis and introduces microvesicle-bacteria aggregation as a potentially useful parameter for making early clinical management decisions.Sepsis is a severe medical condition and a leading cause of hospital mortality. Prompt diagnosis and early treatment has a significant, positive impact on patient outcome. However, sepsis is not always easy to diagnose, especially in critically ill patients. Here, we present a conceptionally new approach for the rapid diagnostic differentiation of sepsis from non-septic intensive care unit patients. Using advanced microscopy and spectroscopy techniques, we measure infection-specific changes in the activity of nano-sized cell-derived microvesicles to bind bacteria. We report on the use of a point-of-care-compatible microfluidic chip to measure microvesicle-bacteria aggregation and demonstrate rapid (<=1.5 hour) and reliable diagnostic differentiation of bacterial infection from non-infectious inflammation in a double-blind pilot study. Our study demonstrates the potential of microvesicle activities for sepsis diagnosis and introduces microvesicle-bacteria aggregation as a potentially useful parameter for making early clinical management decisions. Electronic supplementary information (ESI) available: Fig. S1: Markers of inflammation and microvesicle characteristics in patient plasma samples, Fig. S2: Experimental sepsis model, Table S1: Patient characteristics. Table S2: Inclusion/exclusion criteria. See DOI: 10.1039/c5nr01851j

  20. Shedding Light on Nanomedicine

    PubMed Central

    Tong, Rong

    2012-01-01

    Light is electromagnetic radiation that can convert its energy into different forms (e.g., heat, chemical energy, and acoustic waves). This property has been exploited in phototherapy (e.g., photothermal therapy and photodynamic therapy) and optical imaging (e.g., fluorescence imaging) for therapeutic and diagnostic purposes. Light-controlled therapies can provide minimally or non-invasive spatiotemporal control as well as deep tissue penetration. Nanotechnology provides a numerous advantages, including selective targeting of tissues, prolongation of therapeutic effect, protection of active payloads, and improved therapeutic indices. This review explores the advances that nanotechnology can bring to light-based therapies and diagnostics, and vice versa, including photo-triggered systems, nanoparticles containing photoactive molecules, and nanoparticles that are themselves photoactive. Limitations of light-based therapies such as photic injury and phototoxicity will be discussed. PMID:22887840

  1. Theranostic barcoded nanoparticles for personalized cancer medicine

    PubMed Central

    Yaari, Zvi; da Silva, Dana; Zinger, Assaf; Goldman, Evgeniya; Kajal, Ashima; Tshuva, Rafi; Barak, Efrat; Dahan, Nitsan; Hershkovitz, Dov; Goldfeder, Mor; Roitman, Janna Shainsky; Schroeder, Avi

    2016-01-01

    Personalized medicine promises to revolutionize cancer therapy by matching the most effective treatment to the individual patient. Using a nanoparticle-based system, we predict the therapeutic potency of anticancer medicines in a personalized manner. We carry out the diagnostic stage through a multidrug screen performed inside the tumour, extracting drug activity information with single cell sensitivity. By using 100 nm liposomes, loaded with various cancer drugs and corresponding synthetic DNA barcodes, we find a correlation between the cell viability and the drug it was exposed to, according to the matching barcodes. Based on this screen, we devise a treatment protocol for mice bearing triple-negative breast-cancer tumours, and its results confirm the diagnostic prediction. We show that the use of nanotechnology in cancer care is effective for generating personalized treatment protocols. PMID:27830705

  2. Deepening Prospective Mathematics Teachers' Diagnostic Judgments: Interplay of Videos, Focus Questions and Didactic Categories

    ERIC Educational Resources Information Center

    Prediger, Susanne; Zindel, Carina

    2017-01-01

    This article combines different conceptualizations of teachers' diagnostic competence in listening to students' mathematical thinking processes on the levels of general perspectives, noticed aspects and activated didactic categories. An empirical study of 159 prospective mathematics teachers' diagnostic judgments investigated how these levels are…

  3. Sampling and RNA quality for successful diagnostics using quantitative PCR

    USDA-ARS?s Scientific Manuscript database

    Diagnostic analyses of RNA targets are widely used in honey bee pathology. These diagnostics can be compromised by the actions of endogenous RNA-degrading enzymes activated upon bee death. RNA degradation can be minimized by storage at ultra-cold temperatures or by immersion in high-salt buffers. H...

  4. A Genuine TEAM Player

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Qualtech Systems, Inc. developed a complete software system with capabilities of multisignal modeling, diagnostic analysis, run-time diagnostic operations, and intelligent interactive reasoners. Commercially available as the TEAMS (Testability Engineering and Maintenance System) tool set, the software can be used to reveal unanticipated system failures. The TEAMS software package is broken down into four companion tools: TEAMS-RT, TEAMATE, TEAMS-KB, and TEAMS-RDS. TEAMS-RT identifies good, bad, and suspect components in the system in real-time. It reports system health results from onboard tests, and detects and isolates failures within the system, allowing for rapid fault isolation. TEAMATE takes over from where TEAMS-RT left off by intelligently guiding the maintenance technician through the troubleshooting procedure, repair actions, and operational checkout. TEAMS-KB serves as a model management and collection tool. TEAMS-RDS (TEAMS-Remote Diagnostic Server) has the ability to continuously assess a system and isolate any failure in that system or its components, in real time. RDS incorporates TEAMS-RT, TEAMATE, and TEAMS-KB in a large-scale server architecture capable of providing advanced diagnostic and maintenance functions over a network, such as the Internet, with a web browser user interface.

  5. Rocket engine diagnostics using qualitative modeling techniques

    NASA Technical Reports Server (NTRS)

    Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy

    1992-01-01

    Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system has been created. The qualitative model describes the effects of seal failures on the system steady-state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.

  6. Rocket engine diagnostics using qualitative modeling techniques

    NASA Technical Reports Server (NTRS)

    Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy

    1992-01-01

    Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system was created. The qualitative model describes the effects of seal failures on the system steady state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.

  7. Reusable rocket engine intelligent control system framework design, phase 2

    NASA Technical Reports Server (NTRS)

    Nemeth, ED; Anderson, Ron; Ols, Joe; Olsasky, Mark

    1991-01-01

    Elements of an advanced functional framework for reusable rocket engine propulsion system control are presented for the Space Shuttle Main Engine (SSME) demonstration case. Functional elements of the baseline functional framework are defined in detail. The SSME failure modes are evaluated and specific failure modes identified for inclusion in the advanced functional framework diagnostic system. Active control of the SSME start transient is investigated, leading to the identification of a promising approach to mitigating start transient excursions. Key elements of the functional framework are simulated and demonstration cases are provided. Finally, the advanced function framework for control of reusable rocket engines is presented.

  8. Smartphone chloridometer for point-of-care applications

    NASA Astrophysics Data System (ADS)

    Zhang, Chenji; Kim, Jimin P.; Creer, Michael; Yang, Jian; Liu, Zhiwen

    2017-08-01

    Chloride level in sweat is a major diagnostic criterion for cystic fibrosis (CF) and many other health conditions. In an effort to develop a low cost, point-of-care sweat diagnostics system for chloride concentration measurement, we demonstrated a smartphone-based chloridometer to measure sweat chloride by using our recently developed fluorescence chloride sensor. We characterized the performance of our device to validate its clinical potential. The study indicates that our smartphone-based chloridometer may potentially advance the point-of-care diagnostic system by reducing cost and improving diagnostic accuracy.

  9. Decision support in psychiatry – a comparison between the diagnostic outcomes using a computerized decision support system versus manual diagnosis

    PubMed Central

    Bergman, Lars G; Fors, Uno GH

    2008-01-01

    Background Correct diagnosis in psychiatry may be improved by novel diagnostic procedures. Computerized Decision Support Systems (CDSS) are suggested to be able to improve diagnostic procedures, but some studies indicate possible problems. Therefore, it could be important to investigate CDSS systems with regard to their feasibility to improve diagnostic procedures as well as to save time. Methods This study was undertaken to compare the traditional 'paper and pencil' diagnostic method SCID1 with the computer-aided diagnostic system CB-SCID1 to ascertain processing time and accuracy of diagnoses suggested. 63 clinicians volunteered to participate in the study and to solve two paper-based cases using either a CDSS or manually. Results No major difference between paper and pencil and computer-supported diagnosis was found. Where a difference was found it was in favour of paper and pencil. For example, a significantly shorter time was found for paper and pencil for the difficult case, as compared to computer support. A significantly higher number of correct diagnoses were found in the diffilt case for the diagnosis 'Depression' using the paper and pencil method. Although a majority of the clinicians found the computer method supportive and easy to use, it took a longer time and yielded fewer correct diagnoses than with paper and pencil. Conclusion This study could not detect any major difference in diagnostic outcome between traditional paper and pencil methods and computer support for psychiatric diagnosis. Where there were significant differences, traditional paper and pencil methods were better than the tested CDSS and thus we conclude that CDSS for diagnostic procedures may interfere with diagnosis accuracy. A limitation was that most clinicians had not previously used the CDSS system under study. The results of this study, however, confirm that CDSS development for diagnostic purposes in psychiatry has much to deal with before it can be used for routine clinical purposes. PMID:18261222

  10. Expert systems for diagnostic purposes, prospected applications to the radar field

    NASA Astrophysics Data System (ADS)

    Filippi, Riccardo

    Expert systems applied to fault diagnosis, particularly electrical circuit troubleshooting, are introduced. Diagnostic systems consisting of sequences of rules of the symptom-disease type (rule based system) and systems based upon a physical and functional description of the unit subjected to fault diagnosis are treated. Application of such systems to radar equipment troubleshooting, in particular to the transmitter, is discussed.

  11. Active Surveillance of Prostate Cancer: Use, Outcomes, Imaging, and Diagnostic Tools

    PubMed Central

    Tosoian, Jeffrey J; Loeb, Stacy; Epstein, Jonathan I; Turkbey, Baris; Choyke, Peter; Schaeffer, Edward M

    2016-01-01

    Active surveillance (AS) has emerged as a standard management option for men with very low-risk and low-risk prostate cancer, and contemporary data indicate that use of AS is increasing in the United States and abroad. In the favorable-risk population, reports from multiple prospective cohorts indicate a less than 1% likelihood of metastatic disease and prostate cancer-specific mortality over intermediate-term follow-up (median 5 to 6 years). Higher-risk men participating in AS appear to be at increased risk of adverse outcomes, but these populations have not been adequately studied to this point. Although monitoring on AS largely relies on serial prostate biopsy, a procedure associated with significant morbidity, there is a need for improved diagnostic tools for patient selection and monitoring. Revisions from the 2014 International Society of Urologic Pathology consensus conference have yielded a more intuitive reporting system and detailed reporting of low-intermediate grade tumors, which should facilitate the practice of AS. Meanwhile, emerging modalities such as multiparametric magnetic resonance imaging and tissue-based molecular testing have shown prognostic value in some populations. At this time, however, these instruments have not been sufficiently studied to consider their routine, standardized use in the AS setting. Future studies should seek to identify those platforms most informative in the AS population and propose a strategy by which promising diagnostic tools can be safely and efficiently incorporated into clinical practice. PMID:27249729

  12. Applying a Qualitative Modeling Shell to Process Diagnosis: The Caster System. ONR Technical Report #16.

    ERIC Educational Resources Information Center

    Thompson, Timothy F.; Clancey, William J.

    This report describes the application of a shell expert system from the medical diagnostic system, Neomycin, to Caster, a diagnostic system for malfunctions in industrial sandcasting. This system was developed to test the hypothesis that starting with a well-developed classification procedure and a relational language for stating the…

  13. An evidence-based diagnostic classification system for low back pain

    PubMed Central

    Vining, Robert; Potocki, Eric; Seidman, Michael; Morgenthal, A. Paige

    2013-01-01

    Introduction: While clinicians generally accept that musculoskeletal low back pain (LBP) can arise from specific tissues, it remains difficult to confirm specific sources. Methods: Based on evidence supported by diagnostic utility studies, doctors of chiropractic functioning as members of a research clinic created a diagnostic classification system, corresponding exam and checklist based on strength of evidence, and in-office efficiency. Results: The diagnostic classification system contains one screening category, two pain categories: Nociceptive, Neuropathic, one functional evaluation category, and one category for unknown or poorly defined diagnoses. Nociceptive and neuropathic pain categories are each divided into 4 subcategories. Conclusion: This article describes and discusses the strength of evidence surrounding diagnostic categories for an in-office, clinical exam and checklist tool for LBP diagnosis. The use of a standardized tool for diagnosing low back pain in clinical and research settings is encouraged. PMID:23997245

  14. The production of radionuclides for nuclear medicine from a compact, low-energy accelerator system.

    PubMed

    Webster, William D; Parks, Geoffrey T; Titov, Dmitry; Beasley, Paul

    2014-05-01

    The field of nuclear medicine is reliant on radionuclides for medical imaging procedures and radioimmunotherapy (RIT). The recent shut-downs of key radionuclide producers have highlighted the fragility of the current radionuclide supply network, however. To ensure that nuclear medicine can continue to grow, adding new diagnostic and therapy options to healthcare, novel and reliable production methods are required. Siemens are developing a low-energy, high-current - up to 10 MeV and 1 mA respectively - accelerator. The capability of this low-cost, compact system for radionuclide production, for use in nuclear medicine procedures, has been considered. The production of three medically important radionuclides - (89)Zr, (64)Cu, and (103)Pd - has been considered, via the (89)Y(p,n), (64)Ni(p,n) and (103)Rh(p,n) reactions, respectively. Theoretical cross-sections were generated using TALYS and compared to experimental data available from EXFOR. Stopping power values generated by SRIM have been used, with the TALYS-generated excitation functions, to calculate potential yields and isotopic purity in different irradiation regimes. The TALYS excitation functions were found to have a good agreement with the experimental data available from the EXFOR database. It was found that both (89)Zr and (64)Cu could be produced with high isotopic purity (over 99%), with activity yields suitable for medical diagnostics and therapy, at a proton energy of 10MeV. At 10MeV, the irradiation of (103)Rh produced appreciable quantities of (102)Pd, reducing the isotopic purity. A reduction in beam energy to 9.5MeV increased the radioisotopic purity to 99% with only a small reduction in activity yield. This work demonstrates that the low-energy, compact accelerator system under development by Siemens would be capable of providing sufficient quantities of (89)Zr, (64)Cu, and (103)Pd for use in medical diagnostics and therapy. It is suggested that the system could be used to produce many other isotopes currently useful to nuclear medicine. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. A tutorial on the use of ROC analysis for computer-aided diagnostic systems.

    PubMed

    Scheipers, Ulrich; Perrey, Christian; Siebers, Stefan; Hansen, Christian; Ermert, Helmut

    2005-07-01

    The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.

  16. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    PubMed

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  17. Continuing evolution of in-vitro diagnostic instrumentation

    NASA Astrophysics Data System (ADS)

    Cohn, Gerald E.

    2000-04-01

    The synthesis of analytical instrumentation and analytical biochemistry technologies in modern in vitro diagnostic instrumentation continues to generate new systems with improved performance and expanded capability. Detection modalities have expanded to include multichip modes of fluorescence, scattering, luminescence and reflectance so as to accommodate increasingly sophisticated immunochemical and nucleic acid based reagent systems. The time line graph of system development now extends from the earliest automated clinical spectrophotometers through molecule recognition assays and biosensors to the new breakthroughs of biochip and DNA diagnostics. This brief review traces some of the major innovations in the evolution of system technologies and previews the conference program.

  18. Polymeric nanotheranostics for real-time non-invasive optical imaging of breast cancer progression and drug release.

    PubMed

    Ferber, Shiran; Baabur-Cohen, Hemda; Blau, Rachel; Epshtein, Yana; Kisin-Finfer, Einat; Redy, Orit; Shabat, Doron; Satchi-Fainaro, Ronit

    2014-09-28

    Polymeric nanocarriers conjugated with low molecular weight drugs are designed in order to improve their efficacy and toxicity profile. This approach is particularly beneficial for anticancer drugs, where the polymer-drug conjugates selectively accumulate at the tumor site, due to the enhanced permeability and retention (EPR) effect. The conjugated drug is typically inactive, and upon its pH- or enzymatically-triggered release from the carrier, it regains its therapeutic activity. These settings lack information regarding drug-release time, kinetics and location. Thereby, real-time non-invasive intravital monitoring of drug release is required for theranostics (therapy and diagnostics). We present here the design, synthesis and characterization of a theranostic nanomedicine, based on N-(2-hydroxypropyl) methacrylamide (HPMA) copolymer, owing its fluorescence-based monitoring of site-specific drug release to a self-quenched near-infrared fluorescence (NIRF) probe. We designed two HPMA copolymer-based systems that complement to a theranostic nanomedicine. The diagnostic system consists of self-quenched Cy5 (SQ-Cy5) as a reporter probe and the therapeutic system is based on the anticancer agent paclitaxel (PTX). HPMA copolymer-PTX/SQ-Cy5 systems enable site-specific release upon enzymatic degradation in cathepsin B-overexpressing breast cancer cells. The release of the drug occurs concomitantly with the activation of the fluorophore to its Turn-ON state. HPMA copolymer-SQ-Cy5 exhibits preferable body distribution and drug release compared with the free drug and probe when administered to cathepsin B-overexpressing 4T1 murine mammary adenocarcinoma-bearing mice. This approach of co-delivery of two complementary systems serves as a proof-of-concept for real-time deep tissue intravital orthotopic monitoring and may have the potential use in clinical utility as a theranostic nanomedicine. Copyright © 2014. Published by Elsevier Ireland Ltd.

  19. Implication of Gastric Cancer Molecular Genetic Markers in Surgical Practice.

    PubMed

    Nemtsova, Marina V; Strelnikov, Vladimir V; Tanas, Alexander S; Bykov, Igor I; Zaletaev, Dmitry V; Rudenko, Viktoria V; Glukhov, Alexander I; Kchorobrich, Tatiana V; Li, Yi; Tarasov, Vadim V; Barreto, George E; Aliev, Gjumrakch

    2017-10-01

    We have investigated aberrant methylation of genes CDH1, RASSF1A, MLH1, N33, DAPK, expression of genes hTERT, MMP7, MMP9, BIRC5 (survivin), PTGS2, and activity of telomerase of 106 gastric tumor samples obtained intra-operatively and 53 gastric tumor samples from the same group of patients obtained endoscopically before surgery. Biopsy specimens obtained from 50 patients with chronic calculous cholecystitis were used as a control group. Together with tissue samples obtained from different sites remote to tumors, a total of 727 samples have been studied. The selected parameters comprise a system of molecular markers that can be used in both diagnostics of gastric cancer and in dynamic monitoring of patients after surgery. Special attention was paid to the use of molecular markers for the diagnostics of malignant process in the material obtained endoscopically since the efficacy of morphological diagnostics in biopsies is compromised by intratumoral heterogeneity, which may prevent reliable identification of tumor cells in the sampling. Our data indicated that certain molecular genetic events provided more sensitive yet specific markers of the tumor. We demonstrated that molecular profiles detected in preoperative biopsies were confirmed by the material obtained intra-operatively. The use of endoscopic material facilitates gastric tumors pre-operative diagnostics, improving early detection of gastric cancer and potential effective treatment strategies.

  20. Automated System of Diagnostic Monitoring at Bureya HPP Hydraulic Engineering Installations: a New Level of Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musyurka, A. V., E-mail: musyurkaav@burges.rushydro.ru

    This article presents the design, hardware, and software solutions developed and placed in service for the automated system of diagnostic monitoring (ASDM) for hydraulic engineering installations at the Bureya HPP, and assuring a reliable process for monitoring hydraulic engineering installations. Project implementation represents a timely solution of problems addressed by the hydraulic engineering installation diagnostics section.

  1. Effective Strategies for Diagnosis of Systemic Inflammatory Response Syndrome (SIRS) due to Bacterial Infection in Surgical Patients.

    PubMed

    Stubljar, David; Skvarc, Miha

    2015-01-01

    Surgery associated with trauma and soft tissue injuries after surgery significantly activates the systemic immune response. If an infection after surgery occurs, the response is even stronger. Due to spontaneous activation of immune response and elevated biomarkers for sepsis and cytokines, posttraumatic complications such as new-coming postoperative infections are difficult to diagnose. Sepsis as systemic inflammatory response syndrome (SIRS) rapidly progresses through severe sepsis to septic shock and organ failure, and with no applied antibiotic treatment, the disease often ends at death of the patients. In the treatment of non-surgery patients, the biomarkers like white cell blood count, C-reactive protein (CRP) or procalcitonin (PCT) proved to be useful in sepsis recognition. However, diagnostics after surgeries are more complicated and these biomarkers are not ideal. The solution is a sepsis biomarker, which would have high sensitivity and specificity, that can improve diagnostic accuracy of sepsis, should also be measured easily by the patients, and should not be too expensive. We think more sensitive and specific biomarkers such as presepsin (sCD14-ST) or CD64 index on neutrophils could be useful. A diagnosis of sepsis should be based on clinical signs, and clinicians should use biomarker that is not only most sensitive and specific but also is cost effective. Furthermore, confirmation of the bacterial or fungal infection with blood cultures or with the use of broad range polymerase chain reaction (PCR), when culturing is impossible, should be performed.

  2. Addressing the challenges of diagnostics demand and supply: insights from an online global health discussion platform.

    PubMed

    Engel, Nora; Wachter, Keri; Pai, Madhukar; Gallarda, Jim; Boehme, Catharina; Celentano, Isabelle; Weintraub, Rebecca

    2016-01-01

    Several barriers challenge development, adoption and scale-up of diagnostics in low and middle income countries. An innovative global health discussion platform allows capturing insights from the global health community on factors driving demand and supply for diagnostics. We conducted a qualitative content analysis of the online discussion 'Advancing Care Delivery: Driving Demand and Supply of Diagnostics' organised by the Global Health Delivery Project (GHD) (http://www.ghdonline.org/) at Harvard University. The discussion, driven by 12 expert panellists, explored what must be done to develop delivery systems, business models, new technologies, interoperability standards, and governance mechanisms to ensure that patients receive the right diagnostic at the right time. The GHD Online (GHDonline) platform reaches over 19 000 members from 185 countries. Participants (N=99) in the diagnostics discussion included academics, non-governmental organisations, manufacturers, policymakers, and physicians. Data was coded and overarching categories analysed using qualitative data analysis software. Participants considered technical characteristics of diagnostics as smaller barriers to effective use of diagnostics compared with operational and health system challenges, such as logistics, poor fit with user needs, cost, workforce, infrastructure, access, weak regulation and political commitment. Suggested solutions included: health system strengthening with patient-centred delivery; strengthened innovation processes; improved knowledge base; harmonised guidelines and evaluation; supply chain innovations; and mechanisms for ensuring quality and capacity. Engaging and connecting different actors involved with diagnostic development and use is paramount for improving diagnostics. While the discussion participants were not representative of all actors involved, the platform enabled a discussion between globally acknowledged experts and physicians working in different countries.

  3. Introduction to Advanced Engine Control Concepts

    NASA Technical Reports Server (NTRS)

    Sanjay, Garg

    2007-01-01

    With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of Intelligent Propulsion Systems. The key enabling technologies for an Intelligent Propulsion System are the increased efficiencies of components through active control, advanced diagnostics and prognostics integrated with intelligent engine control to enhance operational reliability and component life, and distributed control with smart sensors and actuators in an adaptive fault tolerant architecture. This presentation describes the current activities of the Controls and Dynamics Branch in the areas of active component control and propulsion system intelligent control, and presents some recent analytical and experimental results in these areas.

  4. Heterodyne laser diagnostic system

    DOEpatents

    Globig, Michael A.; Johnson, Michael A.; Wyeth, Richard W.

    1990-01-01

    The heterodyne laser diagnostic system includes, in one embodiment, an average power pulsed laser optical spectrum analyzer for determining the average power of the pulsed laser. In another embodiment, the system includes a pulsed laser instantaneous optical frequency measurement for determining the instantaneous optical frequency of the pulsed laser.

  5. 21 CFR 884.2980 - Telethermographic system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...

  6. 21 CFR 884.2980 - Telethermographic system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...

  7. 21 CFR 884.2980 - Telethermographic system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...

  8. 21 CFR 884.2980 - Telethermographic system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...

  9. 21 CFR 884.2980 - Telethermographic system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...

  10. Systemic lupus erythematosus: an update.

    PubMed

    Golder, Vera; Hoi, Alberta

    2017-03-20

    Systemic lupus erythematosus (SLE) is a chronic multisystem autoimmune disease predominantly affecting women of childbearing age. New classification criteria for SLE have greater sensitivity and therefore improve the diagnostic certainty for some patients, especially those who may previously have been labelled as having undifferentiated symptoms. Uncontrolled disease activity leads to irreversible end-organ damage, which in turn increases the risk of premature death; early and sustained control of disease activity can usually be achieved by conventional immunosuppressant therapy. The development of biological therapy lags behind that for other rheumatic diseases, with belimumab being the only targeted therapy approved by the Therapeutic Goods Administration. "Treat-to-target" concepts are changing trial design and clinical practice, with evidence-based definition of response criteria in the form of remission and low disease activity now on the horizon. While new therapies are awaited, research should also focus on optimising the use of current therapy and improving the quality of care of patients with SLE.

  11. [Clinical and etiopathogenetic role of plasminogen and metaloproteinase systems in the tumor growth. Pericellular proteolysis of extracellular matrix and tumor growth].

    PubMed

    Cosić, Sanda Jelisavac; Kovac, Zdenko

    2011-01-01

    Pericellular proteolysis is a cascade process involved in degradation of extracellular matrix. This process is included in various physiological and pathological processes. Pericellullar proteolysis has major functions like degradation of tissue stroma and weakening of intercellular connections but it also has a function in the synthesis of bioactive molecules (cytokines, growth factors and inhibitory factors). Plasminogen system is involved in fibrinolysis and starts metalloproteinase activation. Activity of proteolytic molecules is controlled by the rate of zymogenic activation, half-life of molecules, and action of inhibitory molecules. Inhibition is achieved through direct binding of inhibitor and enzyme and takes a few steps. Pericellular proteolysis is involved in tumor invasion and metastasis, inflammatory reaction, degenerative diseases and other diseases. Pathophysiological regulation of pericellular proteolysis in mentioned diseases contributes to clinical properties of diseases and has diagnostic and therapeutic importance.

  12. Active and intelligent packaging: The indication of quality and safety.

    PubMed

    Janjarasskul, Theeranun; Suppakul, Panuwat

    2018-03-24

    The food industry has been under growing pressure to feed an exponentially increasing world population and challenged to meet rigorous food safety law and regulation. The plethora of media consumption has provoked consumer demand for safe, sustainable, organic, and wholesome products with "clean" labels. The application of active and intelligent packaging has been commercially adopted by food and pharmaceutical industries as a solution for the future for extending shelf life and simplifying production processes; facilitating complex distribution logistics; reducing, if not eliminating the need for preservatives in food formulations; enabling restricted food packaging applications; providing convenience, improving quality, variety and marketing features; as well as providing essential information to ensure consumer safety. This chapter reviews innovations of active and intelligent packaging which advance packaging technology through both scavenging and releasing systems for shelf life extension, and through diagnostic and identification systems for communicating quality, tracking and brand protection.

  13. Advanced active health monitoring system of liquid rocket engines

    NASA Astrophysics Data System (ADS)

    Qing, Xinlin P.; Wu, Zhanjun; Beard, Shawn; Chang, Fu-Kuo

    2008-11-01

    An advanced SMART TAPE system has been developed for real-time in-situ monitoring and long term tracking of structural integrity of pressure vessels in liquid rocket engines. The practical implementation of the structural health monitoring (SHM) system including distributed sensor network, portable diagnostic hardware and dedicated data analysis software is addressed based on the harsh operating environment. Extensive tests were conducted on a simulated large booster LOX-H2 engine propellant duct to evaluate the survivability and functionality of the system under the operating conditions of typical liquid rocket engines such as cryogenic temperature, vibration loads. The test results demonstrated that the developed SHM system could survive the combined cryogenic temperature and vibration environments and effectively detect cracks as small as 2 mm.

  14. Self-contained microfluidic systems: a review.

    PubMed

    Boyd-Moss, Mitchell; Baratchi, Sara; Di Venere, Martina; Khoshmanesh, Khashayar

    2016-08-16

    Microfluidic systems enable rapid diagnosis, screening and monitoring of diseases and health conditions using small amounts of biological samples and reagents. Despite these remarkable features, conventional microfluidic systems rely on bulky expensive external equipment, which hinders their utility as powerful analysis tools outside of research laboratories. 'Self-contained' microfluidic systems, which contain all necessary components to facilitate a complete assay, have been developed to address this limitation. In this review, we provide an in-depth overview of self-contained microfluidic systems. We categorise these systems based on their operating mechanisms into three major groups: passive, hand-powered and active. Several examples are provided to discuss the structure, capabilities and shortcomings of each group. In particular, we discuss the self-contained microfluidic systems enabled by active mechanisms, due to their unique capability for running multi-step and highly controllable diagnostic assays. Integration of self-contained microfluidic systems with the image acquisition and processing capabilities of smartphones, especially those equipped with accessory optical components, enables highly sensitive and quantitative assays, which are discussed. Finally, the future trends and possible solutions to expand the versatility of self-contained, stand-alone microfluidic platforms are outlined.

  15. Diagnostics aid for mass spectrometer trouble-shooting

    NASA Astrophysics Data System (ADS)

    Filby, E. E.; Rankin, R. A.; Webb, G. W.

    The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho Chemical Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis provides the user with a set of possible solutions to the observed problems, graded as to their probabilities. Besides the trouble-shooting benefits expected from this system, it will also provide structures diagnostic training for lab personnel. In addition, development of the system knowledge base has already produced a better understanding of instrument behavior. Two key findings are that a good user interface is necessary for full acceptance of the tool, and a development system should include standard programming capabilities as well as the expert system shell.

  16. Serum calcification propensity is independently associated with disease activity in systemic lupus erythematosus

    PubMed Central

    Chalikias, George; Tziakas, Dimitrios; Chizzolini, Carlo; Ribi, Camillo; Trendelenburg, Marten; Eisenberger, Ute; Hauser, Thomas; Pasch, Andreas; Huynh-Do, Uyen; Arampatzis, Spyridon

    2018-01-01

    Background Systemic lupus erythematosus (SLE) is associated with severe cardiovascular complications. The T50 score is a novel functional blood test quantifying calcification propensity in serum. High calcification propensity (or low T50) is a strong and independent determinant of all-cause mortality in various patient populations. Methods A total of 168 patients with ≥ 4 American College of Rheumatology (ACR) diagnostic criteria from the Swiss Systemic lupus erythematosus Cohort Study (SSCS) were included in this analysis. Serum calcification propensity was assessed using time-resolved nephelometry. Results The cohort mainly consisted of female (85%), middle-aged (43±14 years) Caucasians (77%). The major determinants of T50 levels included hemoglobin, serum creatinine and serum protein levels explaining 43% of the variation at baseline. Integrating disease activity (SELENA-SLEDAI) into this multivariate model revealed a significant association between disease activity and T50 levels. In a subgroup analysis considering only patients with active disease (SELENA-SLEDAI score ≥4) we found a negative association between T50 and SELENA-SLEDAI score at baseline (Spearman’s rho -0.233, P = 0.02). Conclusions Disease activity and T50 are closely associated. Moreover, T50 levels identify a subgroup of SLE patients with ongoing systemic inflammation as mirrored by increased disease activity. T50 could be a promising biomarker reflecting SLE disease activity and might offer an earlier detection tool for high-risk patients. PMID:29364894

  17. Selection of Atypia/Follicular Lesion of Unknown Significance Patients for Surgery Versus Active Surveillance, Without Using Genetic Testing: A Single Institute Experience, Prospective Analysis, and Recommendations.

    PubMed

    Cohen, Oded; Tzelnick, Sharon; Lahav, Yonatan; Schindel, Doron; Halperin, Doron; Yehuda, Moshe

    2017-07-01

    Atypia/follicular lesion of unknown significance (AUS/FLUS) has variable rates of malignancy. The recommended management includes active surveillance (AS), repeated fine-needle aspiration (RFNA), diagnostic surgery, or genetic testing for malignancy. The objective of this study was to assess the management of AUS/FLUS patients in a dedicated thyroid clinic without implementing genetic testing. This was a single institute cohort study of all patients aged ≥18 years who underwent ultrasound-guided FNA thyroid biopsies between January 2009 and January 2013 and were followed until January 2016. The median follow-up time was 4.6 years (range 3.2-6.8 years). Forty-eight (57%) patients were referred to AS, and 36 (43%) patients were referred for diagnostic surgery. Thirty-six (75%) patients from the AS group underwent RFNA. An additional eight patients from the AS group subsequently underwent diagnostic surgery. Malignancies were found in 15/44 (34%) diagnostic surgical samples, and benign cytologies were found in 61.1% of the RFNAs. Analysis of adherence to follow-up in the 36 AS patients showed an adherence rate of only 53%, with males tending to comply better than females did (31.6% vs. 5.8%, respectively; p = 0.052), especially males in their sixth decade of life. Genetic tests for AUS/FLUS patients are accepted today as complementary evaluations in many well-developed health systems. Yet, when these tests are not feasible due to financial or availability issues, careful management of AUS/FLUS patients may still offer good results in the selection of patients for surgery or AS. The present results also indicate that compliance to follow-up schedules is a major consideration when selecting patients for AS.

  18. Increased Prevalence of Diastolic Heart Failure in Patients with Rheumatoid Arthritis Correlates with Active Disease, but Not with Treatment Type.

    PubMed

    Schau, Thomas; Gottwald, Michael; Arbach, Olga; Seifert, Martin; Schöpp, Maren; Neuß, Michael; Butter, Christian; Zänker, Michael

    2015-11-01

    Although heart failure (HF) is a major cause of premature mortality, there is little information regarding its prevalence and associated risk factors in patients with rheumatoid arthritis (RA). In this study, we evaluated the prevalence of HF in a community-based RA cohort. Further, we investigated the effect of RA activity and present treatment on HF rate and cardiac structure. A diagnostic workup for HF according to the European Society of Cardiology recommendations was performed in 157 patients with RA fulfilling the American College of Rheumatology/European League Against Rheumatism criteria (68% women, age 61 ± 13 yrs) from our outpatient clinic and in 77 age- and sex-matched controls. The prevalence of HF in patients with RA (24%) was unexpectedly high and differed significantly from the control sample (6%, p = 0.001). Diastolic HF was the dominant type (23% vs 6%), and clinical symptoms alone were of low diagnostic value. Active RA (28-joint Disease Activity Score ≥ 2.6: OR 3.4, 95% CI 1.3-9.8) was an independent risk factor of HF, as well as systemic inflammation (erythrocyte sedimentation rate > 16 mm/h: OR 5.4, 95% CI 2.1-16; C-reactive protein > 10 mg/l: OR 2.6, 95% CI 0.8-8.0) and RA duration > 10 years (OR 2.6, 95% CI 1.2-5.8). HF in RA was associated with concentric hypertrophy (48% vs 17%, p < 0.001) and reduced longitudinal strain (-17.2% vs -19.7%, p < 0.001). However, the prevalence of HF was equivalent between the treatment groups [conventional synthetic disease-modifying antirheumatic drugs (DMARD) 25%, tumor necrosis factor inhibitors 22%, other biological DMARD 27%]. Recognition of all diastolic HF in RA requires a complex diagnostic approach. Active rather than inactive RA places patients at a higher risk for HF, whereas influence of RA treatment on HF risk needs to be elucidated in further studies.

  19. Gene expression-based molecular diagnostic system for malignant gliomas is superior to histological diagnosis.

    PubMed

    Shirahata, Mitsuaki; Iwao-Koizumi, Kyoko; Saito, Sakae; Ueno, Noriko; Oda, Masashi; Hashimoto, Nobuo; Takahashi, Jun A; Kato, Kikuya

    2007-12-15

    Current morphology-based glioma classification methods do not adequately reflect the complex biology of gliomas, thus limiting their prognostic ability. In this study, we focused on anaplastic oligodendroglioma and glioblastoma, which typically follow distinct clinical courses. Our goal was to construct a clinically useful molecular diagnostic system based on gene expression profiling. The expression of 3,456 genes in 32 patients, 12 and 20 of whom had prognostically distinct anaplastic oligodendroglioma and glioblastoma, respectively, was measured by PCR array. Next to unsupervised methods, we did supervised analysis using a weighted voting algorithm to construct a diagnostic system discriminating anaplastic oligodendroglioma from glioblastoma. The diagnostic accuracy of this system was evaluated by leave-one-out cross-validation. The clinical utility was tested on a microarray-based data set of 50 malignant gliomas from a previous study. Unsupervised analysis showed divergent global gene expression patterns between the two tumor classes. A supervised binary classification model showed 100% (95% confidence interval, 89.4-100%) diagnostic accuracy by leave-one-out cross-validation using 168 diagnostic genes. Applied to a gene expression data set from a previous study, our model correlated better with outcome than histologic diagnosis, and also displayed 96.6% (28 of 29) consistency with the molecular classification scheme used for these histologically controversial gliomas in the original article. Furthermore, we observed that histologically diagnosed glioblastoma samples that shared anaplastic oligodendroglioma molecular characteristics tended to be associated with longer survival. Our molecular diagnostic system showed reproducible clinical utility and prognostic ability superior to traditional histopathologic diagnosis for malignant glioma.

  20. Diagnostic Performance of Electronic Syndromic Surveillance Systems in Acute Care

    PubMed Central

    Kashiouris, M.; O’Horo, J.C.; Pickering, B.W.; Herasevich, V.

    2013-01-01

    Context Healthcare Electronic Syndromic Surveillance (ESS) is the systematic collection, analysis and interpretation of ongoing clinical data with subsequent dissemination of results, which aid clinical decision-making. Objective To evaluate, classify and analyze the diagnostic performance, strengths and limitations of existing acute care ESS systems. Data Sources All available to us studies in Ovid MEDLINE, Ovid EMBASE, CINAHL and Scopus databases, from as early as January 1972 through the first week of September 2012. Study Selection: Prospective and retrospective trials, examining the diagnostic performance of inpatient ESS and providing objective diagnostic data including sensitivity, specificity, positive and negative predictive values. Data Extraction Two independent reviewers extracted diagnostic performance data on ESS systems, including clinical area, number of decision points, sensitivity and specificity. Positive and negative likelihood ratios were calculated for each healthcare ESS system. A likelihood matrix summarizing the various ESS systems performance was created. Results The described search strategy yielded 1639 articles. Of these, 1497 were excluded on abstract information. After full text review, abstraction and arbitration with a third reviewer, 33 studies met inclusion criteria, reporting 102,611 ESS decision points. The yielded I2 was high (98.8%), precluding meta-analysis. Performance was variable, with sensitivities ranging from 21% –100% and specificities ranging from 5%-100%. Conclusions There is significant heterogeneity in the diagnostic performance of the available ESS implements in acute care, stemming from the wide spectrum of different clinical entities and ESS systems. Based on the results, we introduce a conceptual framework using a likelihood ratio matrix for evaluation and meaningful application of future, frontline clinical decision support systems. PMID:23874359

  1. A Qualitative Analysis of Physician Perspectives on Missed and Delayed Outpatient Diagnosis: The Focus on System-Related Factors.

    PubMed

    Sarkar, Urmimala; Simchowitz, Brett; Bonacum, Doug; Strull, William; Lopez, Andrea; Rotteau, Leahora; Shojania, Kaveh G

    2014-10-01

    Delayed and missed diagnoses lead to significant patient harm. Because physician actions are fundamental to the outpatient diagnostic process, a study was conducted to explore physician perspectives on diagnosis. As part of a quality improvement initiative, an integrated health system conducted six physician focus groups in 2004 and 2005. The focus groups included questions about the process of diagnosis, specific factors contributing to missed diagnosis, use of guidelines, atypical vs. typical presentations of disease, diagnostic tools, and follow-up, all with regard to delays in the diagnostic process. The interviews were analyzed (1) deductively, with application of the Systems Engineering Initiative for Patient Safety (SEIPS) model, which addresses systems design, quality management, job design, and technology implementations that affect safety-related patient and organizational and/or staff outcomes, and (2) inductively, with identification of novel themes using content analysis. A total of 25 physicians participated in the six focus groups, which yielded 12 hours of discussion. Providers identified multiple barriers to timely and accurate diagnosis, including organizational culture, information availability, and communication factors. Multiple themes relating to each of the participants in the diagnostic process-health system, provider, and patient-emerged. Concerns about health system structure and providers' interactions with one another and with patients far exceeded discussion of the cognitive factors that might affect the diagnostic process. The results suggest that, at least in physicians' views, improving the diagnostic process requires attention to the organization of the health system in addition to the cognitive aspects of diagnosis.

  2. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD

    PubMed Central

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B.; Bramsen, Rikke H.; Nielsen, Anni B. S.; Armour, Cherie; Andersen, Søren B.; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E.

    2017-01-01

    ABSTRACT Background: Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives: The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students (N = 4213), chronic pain patients (N = 573), and military personnel (N = 118). Results: Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions: The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD. PMID:29201287

  3. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD.

    PubMed

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B; Bramsen, Rikke H; Nielsen, Anni B S; Armour, Cherie; Andersen, Søren B; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E

    2017-01-01

    Background : Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives : The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students ( N  = 4213), chronic pain patients ( N  = 573), and military personnel ( N  = 118). Results : Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions : The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD.

  4. An Iconic Comparison of Photographs and the Live Television Screen in Visual Diagnostic Ability.

    ERIC Educational Resources Information Center

    Hofer, Jarrel

    This study focused on five major activities: (1) developing an achievement test to measure visual diagnostic ability of television service technicians, (2) assessing the independence of the dimension of visual diagnostic ability, (3) comparing the iconic equivalence of photographs with motion cues and live screen presentations of defective…

  5. How Do Gut Feelings Feature in Tutorial Dialogues on Diagnostic Reasoning in GP Traineeship?

    ERIC Educational Resources Information Center

    Stolper, C. F.; Van de Wiel, M. W. J.; Hendriks, R. H. M.; Van Royen, P.; Van Bokhoven, M. A.; Van der Weijden, T.; Dinant, G. J.

    2015-01-01

    Diagnostic reasoning is considered to be based on the interaction between analytical and non-analytical cognitive processes. Gut feelings, a specific form of non-analytical reasoning, play a substantial role in diagnostic reasoning by general practitioners (GPs) and may activate analytical reasoning. In GP traineeships in the Netherlands, trainees…

  6. 75 FR 24960 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ..., to permit the use of investigational in vitro diagnostic devices to identify chemical, biological... consent is required for the use of an investigational in vitro diagnostic device. This exception will apply to those situations in which the in vitro investigational diagnostic device is used to prepare for...

  7. Diagnostic Classification Models: Which One Should I Use?

    ERIC Educational Resources Information Center

    Jiao, Hong

    2009-01-01

    Diagnostic assessment is currently an active research area in educational measurement. Literature related to diagnostic modeling has been in existence for several decades, but a great deal of research has been conducted within the last decade or so, especially within the last five years. The author summarizes the key components in the application…

  8. Implementation of HIV and Tuberculosis Diagnostics: The Importance of Context.

    PubMed

    Dominique, Joyelle K; Ortiz-Osorno, Alberto A; Fitzgibbon, Joseph; Gnanashanmugam, Devasena; Gilpin, Christopher; Tucker, Timothy; Peel, Sheila; Peter, Trevor; Kim, Peter; Smith, Steven

    2015-10-15

    Novel diagnostics have been widely applied across human immunodeficiency virus (HIV) and tuberculosis prevention and treatment programs. To achieve the greatest impact, HIV and tuberculosis diagnostic programs must carefully plan and implement within the context of a specific healthcare system and the laboratory capacity. A workshop was convened in Cape Town in September 2014. Participants included experts from laboratory and clinical practices, officials from ministries of health, and representatives from industry. The article summarizes best practices, challenges, and lessons learned from implementation experiences across sub-Saharan Africa for (1) building laboratory programs within the context of a healthcare system; (2) utilizing experience of clinicians and healthcare partners in planning and implementing the right diagnostic; and (3) evaluating the effects of new diagnostics on the healthcare system and on patient health outcomes. The successful implementation of HIV and tuberculosis diagnostics in resource-limited settings relies on careful consideration of each specific context. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  9. Memory Activation and the Availability of Explanations in Sequential Diagnostic Reasoning

    ERIC Educational Resources Information Center

    Mehlhorn, Katja; Taatgen, Niels A.; Lebiere, Christian; Krems, Josef F.

    2011-01-01

    In the field of diagnostic reasoning, it has been argued that memory activation can provide the reasoner with a subset of possible explanations from memory that are highly adaptive for the task at hand. However, few studies have experimentally tested this assumption. Even less empirical and theoretical work has investigated how newly incoming…

  10. 30 CFR 250.522 - When do I have to repeat casing diagnostic testing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., previously on gas lift, has been shut-in or returned to flowing status without gas lift for more than 180... active gas lift are exempt from diagnostic testing. (c) your casing pressure request becomes invalid... percent of its minimum internal yield pressure (MIYP), except for production casings on active gas lift...

  11. 78 FR 60245 - Privacy Act Systems of Records; LabWare Laboratory Information Management System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ... Services Laboratories (NVSL). Diagnostic testing provides official test results for animal imports, exports.... Diagnostic testing is also done in connection with suspected foreign animal disease investigations and... of Records; LabWare Laboratory Information Management System AGENCY: Animal and Plant Health...

  12. High bandwidth vapor density diagnostic system

    DOEpatents

    Globig, Michael A.; Story, Thomas W.

    1992-01-01

    A high bandwidth vapor density diagnostic system for measuring the density of an atomic vapor during one or more photoionization events. The system translates the measurements from a low frequency region to a high frequency, relatively noise-free region in the spectrum to provide improved signal to noise ratio.

  13. Enormous knowledge base of disease diagnosis criteria.

    PubMed

    Xiao, Z H; Xiao, Y H; Pei, J H

    1995-01-01

    One of the problems in the development of the medical knowledge systems is the limitations of the system's knowledge. It is a common expectation to increase the number of diseases contained in a system. Using a high density knowledge representation method designed by us, we have developed the Enormous Knowledge Base of Disease Diagnosis Criteria (EKBDDC). It contains diagnostic criteria of 1,001 diagnostic entities and describes nearly 4,000 items of diagnostic indicators. It is the core of a huge medical project--the Electronic-Brain Medical Erudite (EBME). This enormous knowledge base was implemented initially on a low-cost popular microcomputer, which can aid in the prompting of typical disease and in teaching of diagnosis. The knowledge base is easy to expand. One of the main goals of EKBDDC is to increase the number of diseases included in it as far as possible using a low-cost computer with a comparatively small storage capacity. For this, we have designed a high density knowledge representation method. Criteria of various diagnostic entities are respectively stored in different records of the knowledge base. Each diagnostic entity corresponds to a diagnostic criterion data set; each data set consists of some diagnostic criterion data values (Table 1); each data is composed of two parts: integer and decimal; the integral part is the coding number of the given diagnostic information, and the decimal part is the diagnostic value of this information to the disease indicated by corresponding record number. For example, 75.02: the integer 75 is the coding number of "hemorrhagic skin rash"; the decimal 0.02 is the diagnostic value of this manifestation for diagnosing allergic purpura. TABULAR DATA, SEE PUBLISHED ABSTRACT. The algebraic sum method, a special form of the weighted summation, is adopted as mathematical model. In EKBDDC, the diagnostic values, which represent the significance of the disease manifestations for diagnosing corresponding diseases, were determined empirically. It is of a great economical, practical, and technical significance to realize enormous knowledge bases of disease diagnosis criteria on a low-cost popular microcomputer. This is beneficial for the developing countries to popularize medical informatics. To create the enormous international computer-aided diagnosis system, one may jointly develop the unified modules of disease diagnosis criteria used to "inlay" relevant computer-aided diagnosis systems. It is just like assembling a house using prefabricated panels.

  14. A portable hardware-in-the-loop (HIL) device for automotive diagnostic control systems.

    PubMed

    Palladino, A; Fiengo, G; Lanzo, D

    2012-01-01

    In-vehicle driving tests for evaluating the performance and diagnostic functionalities of engine control systems are often time consuming, expensive, and not reproducible. Using a hardware-in-the-loop (HIL) simulation approach, new control strategies and diagnostic functions on a controller area network (CAN) line can be easily tested in real time, in order to reduce the effort and the cost of the testing phase. Nowadays, spark ignition engines are controlled by an electronic control unit (ECU) with a large number of embedded sensors and actuators. In order to meet the rising demand of lower emissions and fuel consumption, an increasing number of control functions are added into such a unit. This work aims at presenting a portable electronic environment system, suited for HIL simulations, in order to test the engine control software and the diagnostic functionality on a CAN line, respectively, through non-regression and diagnostic tests. The performances of the proposed electronic device, called a micro hardware-in-the-loop system, are presented through the testing of the engine management system software of a 1.6 l Fiat gasoline engine with variable valve actuation for the ECU development version. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Android based self-diagnostic electrocardiogram system for mobile healthcare.

    PubMed

    Choo, Kan-Yeep; Ling, Huo-Chong; Lo, Yew-Chiong; Yap, Zuo-Han; Pua, Jun-Sheng; Phan, Raphael C-W; Goh, Vik-Tor

    2015-01-01

    Cardiovascular diseases are the most common cause of death worldwide and are characterized by arrhythmia (i.e. irregular rhythm of heartbeat). Arrhythmia occasionally happens under certain conditions, such as stress. Therefore, it is difficult to be diagnosed using electrocardiogram (ECG) devices available in hospitals for just a few minutes. Constant diagnosis and monitoring of heartbeat is required to reduce death caused by cardiovascular diseases. Mobile healthcare system has emerged as a potential solution to assist patients in monitoring their own heart condition, especially those who are isolated from the reference hospital. This paper proposes a self-diagnostic electrocardiogram system for mobile healthcare that has the capability to perform a real-time ECG diagnostic. The self-diagnostic capability of a real-time ECG signal is achieved by implementing a detrended fluctuation analysis (DFA) method. The result obtained from DFA is used to display the patient's health condition on a smartphone anytime and anywhere. If the health condition is critical, the system will alert the patient and his medical practitioner for further diagnosis. Experimental results verified the validity of the developed ECG diagnostic application on a smartphone. The proposed system can potentially reduce death caused by cardiovascular diseases by alerting the patient possibly undergoing a heart attack.

  16. Current limitations and recommendations to improve testing ...

    EPA Pesticide Factsheets

    In this paper existing regulatory frameworks and test systems for assessing potential endocrine-active chemicals are described, and associated challenges discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across organizations, but all basically evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or the environment. Current test systems include in silico, in vitro and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect apical data to detect possible adverse effects. These test systems are currently designed to robustly assess endocrine activity and/or adverse effects in the estrogen, androgen, and thyroid hormonal pathways; however, there are some limitations of current test systems for evaluating endocrine hazard and risk. These limitations include a lack of certainty regarding: 1)adequately sensitive species and life-stages, 2) mechanistic endpoints that are diagnostic for endocrine pathways of concern, and 3) the linkage between mechanistic responses and apical, adverse outcomes. Furthermore, some existing test methods are resource intensive in regard to time, cost, and use of animals. However, based on recent experiences, there are opportunities to improve approaches to, and guidance for existing test methods, and to reduce uncertainty. For example, in vitro high throughput

  17. The contribution of the vaccine adverse event text mining system to the classification of possible Guillain-Barré syndrome reports.

    PubMed

    Botsis, T; Woo, E J; Ball, R

    2013-01-01

    We previously demonstrated that a general purpose text mining system, the Vaccine adverse event Text Mining (VaeTM) system, could be used to automatically classify reports of an-aphylaxis for post-marketing safety surveillance of vaccines. To evaluate the ability of VaeTM to classify reports to the Vaccine Adverse Event Reporting System (VAERS) of possible Guillain-Barré Syndrome (GBS). We used VaeTM to extract the key diagnostic features from the text of reports in VAERS. Then, we applied the Brighton Collaboration (BC) case definition for GBS, and an information retrieval strategy (i.e. the vector space model) to quantify the specific information that is included in the key features extracted by VaeTM and compared it with the encoded information that is already stored in VAERS as Medical Dictionary for Regulatory Activities (MedDRA) Preferred Terms (PTs). We also evaluated the contribution of the primary (diagnosis and cause of death) and secondary (second level diagnosis and symptoms) diagnostic VaeTM-based features to the total VaeTM-based information. MedDRA captured more information and better supported the classification of reports for GBS than VaeTM (AUC: 0.904 vs. 0.777); the lower performance of VaeTM is likely due to the lack of extraction by VaeTM of specific laboratory results that are included in the BC criteria for GBS. On the other hand, the VaeTM-based classification exhibited greater specificity than the MedDRA-based approach (94.96% vs. 87.65%). Most of the VaeTM-based information was contained in the secondary diagnostic features. For GBS, clinical signs and symptoms alone are not sufficient to match MedDRA coding for purposes of case classification, but are preferred if specificity is the priority.

  18. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  19. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  20. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  1. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  2. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  3. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  4. Evaluation of a Diagnostic Encyclopedia Workstation for ovarian pathology.

    PubMed

    van Ginneken, A M; Baak, J P; Jansen, W; Smeulders, A W

    1990-10-01

    The Diagnostic Encyclopedia Workstation (DEW) is a computer system that provides completely integrated pictorial and textual information as reference knowledge in the field of ovarian pathology. The textual component comprises information per diagnosis such as descriptions of macroscopic and microscopic images, clinical signs, and prognosis. In addition, the system offers lists of differential diagnoses and criteria to differentiate among lists of differential diagnoses and criteria to differentiate among them. The present study evaluates to what extent the system influences the diagnostic process in efficiency and outcome. Therefore, two groups of six pathologists each, covering a wide spectrum of experience in ovarian pathology, participated in the evaluation of the DEW. The quality of the resulting diagnoses was statistically analyzed with the Wilcoxon rank sum test with respect to five different viewpoints: classification, morphology, clinical consequences, duration of diagnostic process, and consensus among the participants. The results are discussed and it is concluded that classification and morphology showed better results when books were used. The evaluation experiment was, however, very rigid and negatively biased with respect to the DEW system. Positive aspects of the encyclopedia are the easy access to diagnostic and differential diagnostic information and the large set of illustrations. Insight is acquired with respect to existing bottlenecks and how they may be overcome.

  5. An overview of beam diagnostic and control systems for 50 MeV AREAL Linac

    NASA Astrophysics Data System (ADS)

    Sargsyan, A. A.; Amatuni, G. A.; Sahakyan, V. V.; Zanyan, G. S.; Martirosyan, N. W.; Vardanyan, V. V.; Grigoryan, B. A.

    2017-03-01

    Advanced Research Electron Accelerator Laboratory (AREAL) is an electron linear accelerator project with a laser driven RF gun being constructed at CANDLE Synchrotron Research Institute. After the successful operation of the gun section at 5 MeV, a program of facility energy enhancement up to 50 MeV is launched. In this paper the current status of existing diagnostic and control systems, as well as the results of electron beam parameter measurements are presented. The approaches of intended diagnostic and control systems for the upgrade program are also described.

  6. Getting expert systems off the ground: Lessons learned from integrating model-based diagnostics with prototype flight hardware

    NASA Technical Reports Server (NTRS)

    Stephan, Amy; Erikson, Carol A.

    1991-01-01

    As an initial attempt to introduce expert system technology into an onboard environment, a model based diagnostic system using the TRW MARPLE software tool was integrated with prototype flight hardware and its corresponding control software. Because this experiment was designed primarily to test the effectiveness of the model based reasoning technique used, the expert system ran on a separate hardware platform, and interactions between the control software and the model based diagnostics were limited. While this project met its objective of showing that model based reasoning can effectively isolate failures in flight hardware, it also identified the need for an integrated development path for expert system and control software for onboard applications. In developing expert systems that are ready for flight, artificial intelligence techniques must be evaluated to determine whether they offer a real advantage onboard, identify which diagnostic functions should be performed by the expert systems and which are better left to the procedural software, and work closely with both the hardware and the software developers from the beginning of a project to produce a well designed and thoroughly integrated application.

  7. Computer-aided diagnosis workstation and teleradiology network system for chest diagnosis using the web medical image conference system with a new information security solution

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki

    2010-03-01

    Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our teleradiology network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  8. A qualitative approach to systemic diagnosis of the SSME

    NASA Technical Reports Server (NTRS)

    Bickmore, Timothy W.; Maul, William A.

    1993-01-01

    A generic software architecture has been developed for posttest diagnostics of rocket engines, and is presently being applied to the posttest analysis of the SSME. This investigation deals with the Systems Section module of the architecture, which is presently under development. Overviews of the manual SSME systems analysis process and the overall SSME diagnostic system architecture are presented.

  9. 40 CFR 86.099-17 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of computer codes. The emission control diagnostic system shall record and store in computer memory..., shall be stored in computer memory to identify correctly functioning emission control systems and those... in computer memory. Should a subsequent fuel system or misfire malfunction occur, any previously...

  10. 40 CFR 86.099-17 - Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of computer codes. The emission control diagnostic system shall record and store in computer memory..., shall be stored in computer memory to identify correctly functioning emission control systems and those... in computer memory. Should a subsequent fuel system or misfire malfunction occur, any previously...

  11. Kounis Syndrome During Anesthesia: Presentation of Indolent Systemic Mastocytosis: A Case Report.

    PubMed

    de la Fuente Tornero, Elena; Vega Castro, Arantza; de Sierra Hernández, Pedro Álvarez; Balaguer Recena, Javier; Zaragoza Casares, Sofía Carmen; Serrano Baylin, Francisco Miguel; Gallardo Culebradas, Paloma; Amorós Alfonso, Beatriz; Rodríguez Fraile, Jose Ramón

    2017-05-01

    Mastocytosis comprises a heterogeneous group of disorders characterized by mast cell accumulation and proliferation in distinct organs. Kounis syndrome is defined as the concurrence of acute coronary syndromes with mast cell activation in a setting of allergic or hypersensitivity reactions. This is the first reported case of an intraoperative Kounis syndrome as the onset of an indolent systemic mastocytosis probably triggered by succinylated gelatin infusion during general anesthesia. The presentation of this case is intended to contribute to the knowledge of mastocytosis and Kounis syndrome at the time of diagnostic workup during intraoperative anaphylaxis or myocardial ischemia.

  12. LASER BIOLOGY AND MEDICINE: A laser-spectroscopy system for fluorescent diagnostics and photodynamic therapy of diseases of eye retina and choroid

    NASA Astrophysics Data System (ADS)

    Meerovich, G. A.; Shevchik, S. A.; Loshchenov, M. V.; Budzinskaya, M. V.; Ermakova, N. A.; Kharnas, S. S.

    2002-11-01

    A laser-spectroscopy system for the fluorescent diagnostics and photodynamic therapy of pathologic eye-fundus changes combined with the use of the Photosens compound is developed. The system is tested on experimental animals (mice and rabbits).

  13. Application of Adaptive Decision Aiding Systems to Computer-Assisted Instruction. Final Report, January-December 1974.

    ERIC Educational Resources Information Center

    May, Donald M.; And Others

    The minicomputer-based Computerized Diagnostic and Decision Training (CDDT) system described combines the principles of artificial intelligence, decision theory, and adaptive computer assisted instruction for training in electronic troubleshooting. The system incorporates an adaptive computer program which learns the student's diagnostic and…

  14. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Diagnostic x-ray system means an x-ray system designed for irradiation of any part of the human body for the... HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING... for the radiographic visualization and measurement of the dimensions of the human head. Coefficient of...

  15. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Diagnostic x-ray system means an x-ray system designed for irradiation of any part of the human body for the... HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING... for the radiographic visualization and measurement of the dimensions of the human head. Coefficient of...

  16. Activated human neutrophil response to perfluorocarbon nanobubbles: oxygen-dependent and -independent cytotoxic responses.

    PubMed

    Hwang, Tsong-Long; Fang, Chia-Lang; Al-Suwayeh, Saleh A; Yang, Li-Jia; Fang, Jia-You

    2011-06-10

    Nanobubbles, a type of nanoparticles with acoustically active properties, are being utilized as diagnostic and therapeutic nanoparticles to better understand, detect, and treat human diseases. The objective of this work was to prepare different nanobubble formulations and investigate their physicochemical characteristics and toxic responses to N-formyl-methionyl-leucyl-phenylalanine (fMLP)-activated human neutrophils. The nanobubbles were prepared using perfluoropentane and coconut oil as the respective core and shell, with soybean phosphatidylcholine (SPC) and/or cationic surfactants as the interfacial layers. The cytotoxic effect of the nanobubbles on neutrophils was determined by extracellular O₂(.)⁻ release, intracellular reactive oxygen species (ROS), lactate dehydrogenase (LDH), and elastase release. Particle sizes of the nanobubbles with different percentages of perfluorocarbon, oil, and surfactants in ranged 186-432 nm. The nanobubbles were demonstrated to inhibit the generation of superoxide and intracellular ROS. The cytotoxicity of nanobubbles may be mainly associated with membrane damage, as indicated by the high LDH leakage. Systems with Forestall (FE), a cationic surfactant, or higher SPC contents exhibited the greatest LDH release by 3-fold compared to the control. The further addition of an oil component reduced the cytotoxicity induced by the nanobubbles. Exposure to most of the nanobubble formulations upregulated elastase release by activated neutrophils. Contrary to this result, stearylamine (SA)-containing systems slightly but significantly suppressed elastase release. FE and SA in a free form caused stronger responses by neutrophils than when they were incorporated into nanobubbles. In summary, exposure to nanobubbles resulted in a formulation-dependent toxicity toward human neutrophils that was associated with both oxygen-dependent and -independent pathways. Clinicians should therefore exercise caution when using nanobubbles in patients for diagnostic and drug targeting aims. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Micro-RNAs as regulators and possible diagnostic bio-markers in inflammatory bowel disease.

    PubMed

    Archanioti, Paraskevi; Gazouli, Maria; Theodoropoulos, George; Vaiopoulou, Anna; Nikiteas, Nikolaos

    2011-12-01

    Not fully defined pathophysiologic mechanisms of inflammatory bowel disease (IBD) involve an array of genetic, epigenetic, infectious, physiological and immunological factors. Nowadays, an inadequate activation of the innate immune system to a luminal factor occurring in genetically predisposed subjects is the most widely accepted today. Micro-autoimmune diseases, a group of small, single-stranded, non-coding RNA molecules act as potent negative gene regulators. Beyond cancer and various autoimmune diseases, their impact on IBD has recently been the focus of research. Differential expression of various micro-RNAs has been documented in active and inactive ulcerative colitis, while micro-RNA profile appears to differ between ileal and colonic Crohn's disease. Except for tissue samples, attempts have been made to estimate similar differences at patients' blood samples. Apart from offering new directions in related research, these molecules arise as useful diagnostic tools and potential therapeutic targets. This review focuses on micro-RNA alterations in IBD and their potential implication on immunologic deregulation. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  18. [Diagnostic Significance of BAT in Anaphylaxis to Non-ionic Contrast Media].

    PubMed

    Zhang, Hao-yue; Xu, Su-jun; Tang, Xiao-xian; Niu, Ji-jun; Guo, Xiang-jie; Gao, Cai-rong

    2015-06-01

    To investigate the diagnostic significance of basophil activation test (BAT) in anaphylaxis to non-ionic contrast media through testing the content of CD63, mast cell-carboxypeptidase A3 (MC-CPA3), and terminal complement complex SC5b-9 of the individuals by testing their levels in the normal immune group and the anaphylaxis groups to β-lactam drugs and non -ionic contrast media. The CD63 expression of basophilic granulocyte in blood was detected by flow cytometry. The levels of MC-CPA3 in blood serum and SC5b-9 in blood plasma were detected by ELISA. The CD63 expression of basophilic granulocyte in blood, the levels of MC-CPA3 and SC5b-9 of anaphylaxis to non-ionic contrast media and β-lactam drugs were significantly higher than that in normal immune group (P < 0.05). There is activation of basophilic granulocytes, mast cells and complement system in anaphylaxis to non-ionic contrast media. BAT can be used to diagnose the anaphylaxis to non-ionic contrast media.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Y.; Tobias, B.; Chang, Y. -T.

    Electron cyclotron emission (ECE) imaging is a passive radiometric technique that measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) is an active radar imaging technique that measures electron density fluctuations. The microwave imaging diagnostic instruments employing these techniques have made important contributions to fusion science and have been adopted at major fusion facilities worldwide including DIII-D, EAST, ASDEX Upgrade, HL-2A, KSTAR, LHD, and J-TEXT. In this paper, we describe the development status of three major technological advancements: custom mm-wave integrated circuits (ICs), digital beamforming (DBF), and synthetic diagnostic modeling (SDM). These also have the potential to greatly advance microwavemore » fusion plasma imaging, enabling compact and low-noise transceiver systems with real-time, fast tracking ability to address critical fusion physics issues, including ELM suppression and disruptions in the ITER baseline scenario, naturally ELM-free states such as QH-mode, and energetic particle confinement (i.e. Alfven eigenmode stability) in high-performance regimes that include steady-state and advanced tokamak scenarios. Furthermore, these systems are fully compatible with today's most challenging non-inductive heating and current drive systems and capable of operating in harsh environments, making them the ideal approach for diagnosing long-pulse and steady-state tokamaks.« less

  20. A Potent, Imaging Adenoviral Vector Driven by the Cancer-selective Mucin-1 Promoter That Targets Breast Cancer Metastasis

    PubMed Central

    Huyn, Steven T.; Burton, Jeremy B.; Sato, Makoto; Carey, Michael; Gambhir, Sanjiv S.; Wu, Lily

    2009-01-01

    Purpose With breast cancer, early detection and proper staging are critical, and will often influence both the treatment regimen and the therapeutic outcome for those affected with this disease. Improvements in these areas will play a profound role in reducing mortality from breast cancer. Experimental Design In this work we developed a breast cancer – targeted serotype 5 adenoviral vector, utilizing the tumor-specific mucin-1 promoter in combination with the two-step transcriptional amplification system, a system used to augment the activity of weak tissue – specific promoters. Results We showed the strong specificity of this tumor-selective adenovirus to express the luciferase optical imaging gene, leading to diagnostic signals that enabled detection of sentinel lymph node metastasis of breast cancer. Furthermore, we were able to target hepatic metastases following systemic administration of this mucin-1 selective virus. Conclusions Collectively, we showed that the amplified mucin-1 promoter – driven vector is able to deliver to and selectively express a desirable transgene in metastatic lesions of breast tumors. This work has strong clinical relevance to current diagnostic staging approaches, and could add to targeted therapeutic strategies to advance the fight against breast cancer. PMID:19366829

  1. Autonomous power expert fault diagnostic system for Space Station Freedom electrical power system testbed

    NASA Technical Reports Server (NTRS)

    Truong, Long V.; Walters, Jerry L.; Roth, Mary Ellen; Quinn, Todd M.; Krawczonek, Walter M.

    1990-01-01

    The goal of the Autonomous Power System (APS) program is to develop and apply intelligent problem solving and control to the Space Station Freedom Electrical Power System (SSF/EPS) testbed being developed and demonstrated at NASA Lewis Research Center. The objectives of the program are to establish artificial intelligence technology paths, to craft knowledge-based tools with advanced human-operator interfaces for power systems, and to interface and integrate knowledge-based systems with conventional controllers. The Autonomous Power EXpert (APEX) portion of the APS program will integrate a knowledge-based fault diagnostic system and a power resource planner-scheduler. Then APEX will interface on-line with the SSF/EPS testbed and its Power Management Controller (PMC). The key tasks include establishing knowledge bases for system diagnostics, fault detection and isolation analysis, on-line information accessing through PMC, enhanced data management, and multiple-level, object-oriented operator displays. The first prototype of the diagnostic expert system for fault detection and isolation has been developed. The knowledge bases and the rule-based model that were developed for the Power Distribution Control Unit subsystem of the SSF/EPS testbed are described. A corresponding troubleshooting technique is also described.

  2. Process-Oriented Diagnostics of Tropical Cyclones in Global Climate Models

    NASA Astrophysics Data System (ADS)

    Moon, Y.; Kim, D.; Camargo, S. J.; Wing, A. A.; Sobel, A. H.; Bosilovich, M. G.; Murakami, H.; Reed, K. A.; Vecchi, G. A.; Wehner, M. F.; Zarzycki, C. M.; Zhao, M.

    2017-12-01

    Simulating tropical cyclone (TC) activity with global climate models (GCMs) remains a challenging problem. While some GCMs are able to simulate TC activity that is in good agreement with the observations, many other models exhibit strong biases. Decreasing horizontal grid spacing of the GCM simulations tends to improve the characteristics of simulated TCs, but this enhancement alone does not necessarily lead to greater skill in simulating TC activity. This study uses process-based diagnostics to identify model characteristics that could explain why some GCM simulations are able to produce more realistic TC activity than others. The diagnostics examine how convection, moisture, clouds and related processes are coupled at individual grid points, which yields useful information into how convective parameterizations interact with resolved model dynamics. These diagnostics share similarities with those originally developed to examine the Madden-Julian Oscillations in climate models. This study will examine TCs in eight different GCM simulations performed at NOAA/GFDL, NCAR and NASA that have different horizontal resolutions and ocean coupling. Preliminary results suggest that stronger TCs are closely associated with greater rainfall - thus greater diabatic heating - in the inner-core regions of the storms, which is consistent with previous theoretical studies. Other storm characteristics that can be used to infer why GCM simulations with comparable horizontal grid spacings produce different TC activity will be examined.

  3. Dual processing and diagnostic errors.

    PubMed

    Norman, Geoff

    2009-09-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical, conscious, and conceptual process, called System 2. Exemplar theories of categorization propose that many category decisions in everyday life are made by unconscious matching to a particular example in memory, and these remain available and retrievable individually. I then review studies of clinical reasoning based on these theories, and show that the two processes are equally effective; System 1, despite its reliance in idiosyncratic, individual experience, is no more prone to cognitive bias or diagnostic error than System 2. Further, I review evidence that instructions directed at encouraging the clinician to explicitly use both strategies can lead to consistent reduction in error rates.

  4. Extracting 3D Information from 1D and 2D Diagnostic Systems on the DIII-D Tokamak

    NASA Astrophysics Data System (ADS)

    Brookman, Michael

    2017-10-01

    The interpretation of tokamak data often hinges on assumptions of axisymetry and flux surface equilibria, neglecting 3D effects. This work discusses examples on the DIII-D tokamak where this assumption is an insufficient approximation, and explores the diagnostic information available to resolve 3D effects while preserving 1D profiles. Methods for extracting 3D data from the electron cyclotron emission radiometers, density profile reflectometer, and Thomson scattering system are discussed. Coordinating diagnostics around the tokamak shows the significance of 3D features, such as sawteeth[1] and resonant magnetic perturbations. A consequence of imposed 3D perturbations is a shift in major radius of measured profiles between diagnostics at different toroidal locations. Integrating different diagnostics requires a database containing information about their toroidal, poloidal, and radial locations. Through the data analysis framework OMFIT, it is possible to measure the magnitude of the apparent shifts from 3D effects and enforce consistency between diagnostics. Using the existing 1D and 2D diagnostic systems on DIII-D, this process allows the effects of the 3D perturbations on 1D profiles to be addressed. Supported by US DOE contracts DE-FC02-04ER54698, DE-FG03-97ER54415.

  5. Note: Neutron bang time diagnostic system on Shenguang-III prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Qi; Chen, Jiabin; Liu, Zhongjie

    A neutron bang time (NBT) diagnostic system has been implemented on Shenguang-III prototype. The bang time diagnostic system is based on a sensitive fusion neutron detector, which consists of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT). An optical fiber bundle is used to couple the scintillator and the PMT. The bang time system is able to measure bang time above a neutron yield of 10{sup 7}. Bang times and start time of laser were related by probing x-ray pulses produced by 200 ps laser irradiating golden targets. Timing accuracy of the NBT is better than 60 ps.

  6. Measuring the impact of diagnostic decision support on the quality of clinical decision making: development of a reliable and valid composite score.

    PubMed

    Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F

    2003-01-01

    Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.

  7. Diagnosing cancer in primary care: results from the National Cancer Diagnosis Audit

    PubMed Central

    Swann, Ruth; McPhail, Sean; Witt, Jana; Shand, Brian; Abel, Gary A; Hiom, Sara; Rashbass, Jem; Lyratzopoulos, Georgios; Rubin, Greg

    2018-01-01

    Background Continual improvements in diagnostic processes are needed to minimise the proportion of patients with cancer who experience diagnostic delays. Clinical audit is a means of achieving this. Aim To characterise key aspects of the diagnostic process for cancer and to generate baseline measures for future re-audit. Design and setting Clinical audit of cancer diagnosis in general practices in England. Method Information on patient and tumour characteristics held in the English National Cancer Registry was supplemented by information from GPs in participating practices. Data items included diagnostic timepoints, patient characteristics, and clinical management. Results Data were collected on 17 042 patients with a new diagnosis of cancer during 2014 from 439 practices. Participating practices were similar to non-participating ones, particularly regarding population age, urban/rural location, and practice-based patient experience measures. The median diagnostic interval for all patients was 40 days (interquartile range [IQR] 15–86 days). Most patients were referred promptly (median primary care interval 5 days [IQR 0–27 days]). Where GPs deemed diagnostic delays to have occurred (22% of cases), patient, clinician, or system factors were responsible in 26%, 28%, and 34% of instances, respectively. Safety netting was recorded for 44% of patients. At least one primary care-led investigation was carried out for 45% of patients. Most patients (76%) had at least one existing comorbid condition; 21% had three or more. Conclusion The findings identify avenues for quality improvement activity and provide a baseline for future audit of the impact of 2015 National Institute for Health and Care Excellence guidance on management and referral of suspected cancer. PMID:29255111

  8. Diagnostic and prognostic value of human prion detection in cerebrospinal fluid.

    PubMed

    Foutz, Aaron; Appleby, Brian S; Hamlin, Clive; Liu, Xiaoqin; Yang, Sheng; Cohen, Yvonne; Chen, Wei; Blevins, Janis; Fausett, Cameron; Wang, Han; Gambetti, Pierluigi; Zhang, Shulin; Hughson, Andrew; Tatsuoka, Curtis; Schonberger, Lawrence B; Cohen, Mark L; Caughey, Byron; Safar, Jiri G

    2017-01-01

    Several prion amplification systems have been proposed for detection of prions in cerebrospinal fluid (CSF), most recently, the measurements of prion seeding activity with second-generation real-time quaking-induced conversion (RT-QuIC). The objective of this study was to investigate the diagnostic performance of the RT-QuIC prion test in the broad phenotypic spectrum of prion diseases. We performed CSF RT-QuIC testing in 2,141 patients who had rapidly progressive neurological disorders, determined diagnostic sensitivity and specificity in 272 cases that were autopsied, and evaluated the impact of mutations and polymorphisms in the PRNP gene, and type 1 or type 2 human prions on diagnostic performance. The 98.5% diagnostic specificity and 92% sensitivity of CSF RT-QuIC in a blinded retrospective analysis matched the 100% specificity and 95% sensitivity of a blind prospective study. The CSF RT-QuIC differentiated 94% of cases of sporadic Creutzfeldt-Jakob disease (sCJD) MM1 from the sCJD MM2 phenotype, and 80% of sCJD VV2 from sCJD VV1. The mixed prion type 1-2 and cases heterozygous for codon 129 generated intermediate CSF RT-QuIC patterns, whereas genetic prion diseases revealed distinct profiles for each PRNP gene mutation. The diagnostic performance of the improved CSF RT-QuIC is superior to surrogate marker tests for prion diseases such as 14-3-3 and tau proteins, and together with PRNP gene sequencing the test allows the major prion subtypes to be differentiated in vivo. This differentiation facilitates prediction of the clinicopathological phenotype and duration of the disease-two important considerations for envisioned therapeutic interventions. ANN NEUROL 2017;81:79-92. © 2016 American Neurological Association.

  9. Diagnostic and Prognostic Value of Human Prion Detection in Cerebrospinal Fluid

    PubMed Central

    Foutz, Aaron; Appleby, Brian S.; Hamlin, Clive; Liu, Xiaoqin; Yang, Sheng; Cohen, Yvonne; Chen, Wei; Blevins, Janis; Fausett, Cameron; Wang, Han; Gambetti, Pierluigi; Zhang, Shulin; Hughson, Andrew; Tatsuoka, Curtis; Schonberger, Lawrence B.; Cohen, Mark L.; Caughey, Byron; Safar, Jiri G.

    2016-01-01

    Objective Several prion amplification systems have been proposed for detection of prions in cerebrospinal fluid (CSF), most recently, the measurements of prion seeding activity with second-generation real-time quaking-induced conversion (RT-QuIC). The objective of this study was to investigate the diagnostic performance of the RT-QuIC prion test in the broad phenotypic spectrum of prion diseases. Methods We performed CSF RT-QuIC testing in 2,141 patients who had rapidly progressive neurological disorders, determined diagnostic sensitivity and specificity in 272 cases which were autopsied, and evaluated the impact of mutations and polymorphisms in the PRNP gene, and Type 1 or Type 2 of human prions on diagnostic performance. Results The 98.5% diagnostic specificity and 92% sensitivity of CSF RT-QuIC in a blinded retrospective analysis matched the 100% specificity and 95% sensitivity of a blind prospective study. The CSF RT-QuIC differentiated 94% of cases of sporadic Creutzfeldt-Jakob disease (sCJD) MM1 from the sCJD MM2 phenotype, and 80% of sCJD VV2 from sCJD VV1. The mixed prion type 1–2 and cases heterozygous for codon 129 generated intermediate CSF RT-QuIC patterns, while genetic prion diseases revealed distinct profiles for each PRNP gene mutation. Interpretation The diagnostic performance of the improved CSF RT-QuIC is superior to surrogate marker tests for prion diseases such as 14-3-3 and Tau proteins and together with PRNP gene sequencing, the test allows the major prion subtypes to be differentiated in vivo. This differentiation facilitates prediction of the clinicopathological phenotype and duration of the disease—two important considerations for envisioned therapeutic interventions. PMID:27893164

  10. Bio-functionalized silk hydrogel microfluidic systems.

    PubMed

    Zhao, Siwei; Chen, Ying; Partlow, Benjamin P; Golding, Anne S; Tseng, Peter; Coburn, Jeannine; Applegate, Matthew B; Moreau, Jodie E; Omenetto, Fiorenzo G; Kaplan, David L

    2016-07-01

    Bio-functionalized microfluidic systems were developed based on a silk protein hydrogel elastomeric materials. A facile multilayer fabrication method using gelatin sacrificial molding and layer-by-layer assembly was implemented to construct interconnected, three dimensional (3D) microchannel networks in silk hydrogels at 100 μm minimum feature resolution. Mechanically activated valves were implemented to demonstrate pneumatic control of microflow. The silk hydrogel microfluidics exhibit controllable mechanical properties, long-term stability in various environmental conditions, tunable in vitro and in vivo degradability in addition to optical transparency, providing unique features for cell/tissue-related applications than conventional polydimethylsiloxane (PDMS) and existing hydrogel-based microfluidic options. As demonstrated in the work here, the all aqueous-based fabrication process at ambient conditions enabled the incorporation of active biological substances in the bulk phase of these new silk microfluidic systems during device fabrication, including enzymes and living cells, which are able to interact with the fluid flow in the microchannels. These silk hydrogel-based microfluidic systems offer new opportunities in engineering active diagnostic devices, tissues and organs that could be integrated in vivo, and for on-chip cell sensing systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Some approaches to medical support for Martian expedition

    NASA Astrophysics Data System (ADS)

    Kozlovskaya, Inessa B.; Egorov, Anatoly D.

    2003-08-01

    Medical support in a Martian expedition will be within the scope of crew responsibilities and maximally autonomous. Requirements to the system of diagnostics in this mission include considerable use of means and methods of visualization of the main physiological parameters, telemedicine, broad usage of biochemical analyses (including "dry" chemistry), computerized collection, measurement, analysis and storage of medical information. The countermeasure system will be based on objective methods of crew fitness and working ability evaluation, individual selection of training regimens, and intensive use of computer controlled training. Implementation of the above principles implies modernization and refinement of the countermeasures currently used by space crews of long-term missions (LTM), and increases of the assortment of active and passive training devices, among them a short-arm centrifuge. The system of medical care with the functions of prevention, clinical diagnostics and timely treatment will be autonomous, too. The general requirements to medical care during the future mission are the following: availability of conditions and means for autonomous urgent and special medical aid and treatment of the most possible states and diseases, "a hospital", and assignment to the crew of one or two doctors. To ensure independence of medical support and medical care in an expedition to Mars an automated expert system needs to be designed and constructed to control the medical situation as a whole.

  12. 76 FR 1169 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ... Labels and in Labeling of In Vitro Diagnostic Devices Intended for Professional Use AGENCY: Food and Drug... Support Use of Symbols on Labels and in Labeling of In Vitro Diagnostic Devices Intended for Professional... required for: (1) In vitro diagnostic devices (IVDs), intended for professional use under 21 CFR 809.10...

  13. Control Method for Video Guidance Sensor System

    NASA Technical Reports Server (NTRS)

    Howard, Richard T. (Inventor); Book, Michael L. (Inventor); Bryan, Thomas C. (Inventor)

    2005-01-01

    A method is provided for controlling operations in a video guidance sensor system wherein images of laser output signals transmitted by the system and returned from a target are captured and processed by the system to produce data used in tracking of the target. Six modes of operation are provided as follows: (i) a reset mode; (ii) a diagnostic mode; (iii) a standby mode; (iv) an acquisition mode; (v) a tracking mode; and (vi) a spot mode wherein captured images of returned laser signals are processed to produce data for all spots found in the image. The method provides for automatic transition to the standby mode from the reset mode after integrity checks are performed and from the diagnostic mode to the reset mode after diagnostic operations are commands is permitted only when the system is in the carried out. Further, acceptance of reset and diagnostic standby mode. The method also provides for automatic transition from the acquisition mode to the tracking mode when an acceptable target is found.

  14. Control method for video guidance sensor system

    NASA Technical Reports Server (NTRS)

    Howard, Richard T. (Inventor); Book, Michael L. (Inventor); Bryan, Thomas C. (Inventor)

    2005-01-01

    A method is provided for controlling operations in a video guidance sensor system wherein images of laser output signals transmitted by the system and returned from a target are captured and processed by the system to produce data used in tracking of the target. Six modes of operation are provided as follows: (i) a reset mode; (ii) a diagnostic mode; (iii) a standby mode; (iv) an acquisition mode; (v) a tracking mode; and (vi) a spot mode wherein captured images of returned laser signals are processed to produce data for all spots found in the image. The method provides for automatic transition to the standby mode from the reset mode after integrity checks are performed and from the diagnostic mode to the reset mode after diagnostic operations are carried out. Further, acceptance of reset and diagnostic commands is permitted only when the system is in the standby mode. The method also provides for automatic transition from the acquisition mode to the tracking mode when an acceptable target is found.

  15. Diagnostic Imaging

    MedlinePlus

    Diagnostic imaging lets doctors look inside your body for clues about a medical condition. A variety of machines and ... and activities inside your body. The type of imaging your doctor uses depends on your symptoms and ...

  16. Present status and perspective of laboratory hematology in Japan: On the standardization of blood cell morphology including myelodysplasia: On behalf of the Japanese Society for Laboratory Hematology.

    PubMed

    Tohyama, K

    2018-05-01

    The Japanese Society for Laboratory Hematology (JSLH) was launched in 2000 and has been developed by a mutual collaboration of hematologists, medical technologists, and the companies involved in hematological laboratory testing. The aim of JSLH is the progress and development of laboratory hematology by academic conferences, periodic publication of academic journal, training and education (in the meeting, the journal, or the website), promotion of the standardization of laboratory hematology, and certification of the laboratory hematology specialists. Among 3 specialized committees organized for the standardization of laboratory hematology, the standardization committee on blood cell morphology has been dealing with the various projects on peripheral/bone marrow blood cells and normal/abnormal morphology. Another independent organization, the Japanese National Research Group on idiopathic bone marrow failure syndromes (BMF), has raised the importance of the dysplasia of myelodysplastic syndromes (MDS) and has been conducting the prospective registration, central review, and follow-up study of MDS. This group recently proposed the grading system for diagnostic accuracy of MDS, and the detailed procedure of morphological diagnosis of MDS is presented in the specialized color atlas with typical photographs of various dysplasia. JSLH has also approved the grading system for diagnostic accuracy of MDS and adopted this standardized diagnostic system to the educational item for certification of the laboratory hematology specialists, aiming at a nationwidely expanding morphological evaluation of myelodysplasia. Further and significant progress in the standardization of blood cell morphology will be expected in Japan through the activity of JSLH. © 2018 John Wiley & Sons Ltd.

  17. Tailoring non-equilibrium atmospheric pressure plasmas for healthcare technologies

    NASA Astrophysics Data System (ADS)

    Gans, Timo

    2012-10-01

    Non-equilibrium plasmas operated at ambient atmospheric pressure are very efficient sources for energy transport through reactive neutral particles (radicals and metastables), charged particles (ions and electrons), UV radiation, and electro-magnetic fields. This includes the unique opportunity to deliver short-lived highly reactive species such as atomic oxygen and atomic nitrogen. Reactive oxygen and nitrogen species can initiate a wide range of reactions in biochemical systems, both therapeutic and toxic. The toxicological implications are not clear, e.g. potential risks through DNA damage. It is anticipated that interactions with biological systems will be governed through synergies between two or more species. Suitable optimized plasma sources are improbable through empirical investigations. Quantifying the power dissipation and energy transport mechanisms through the different interfaces from the plasma regime to ambient air, towards the liquid interface and associated impact on the biological system through a new regime of liquid chemistry initiated by the synergy of delivering multiple energy carrying species, is crucial. The major challenge to overcome the obstacles of quantifying energy transport and controlling power dissipation has been the severe lack of suitable plasma sources and diagnostic techniques. Diagnostics and simulations of this plasma regime are very challenging; the highly pronounced collision dominated plasma dynamics at very small dimensions requires extraordinary high resolution - simultaneously in space (microns) and time (picoseconds). Numerical simulations are equally challenging due to the inherent multi-scale character with very rapid electron collisions on the one extreme and the transport of chemically stable species characterizing completely different domains. This presentation will discuss our recent progress actively combining both advance optical diagnostics and multi-scale computer simulations.

  18. Thyroid stunning: fact or fiction?

    PubMed

    McDougall, I Ross; Iagaru, Andrei

    2011-03-01

    Stunning of thyroid tissue by diagnostic activities of (131)I has been described by some investigators and refuted by others. The support both for and against stunning has at times been enthusiastic and vigorous. We present the data from both sides of the debate in an attempt to highlight the strengths and deficiencies in the investigations cited. Clinical, animal, and in vitro studies are included. There are considerable differences in clinical practice, such as the administered activity for diagnostic whole-body scan, delay between diagnostic scan and treatment, time between treatment and posttherapy scanning, and timing of follow-up studies, that have to be analyzed with care. Other factors that often cannot be judged, such as levels of thyroid-stimulating hormone and serum iodine at time of diagnostic testing versus treatment could have an influence on stunning. Larger diagnostic doses and longer delays to therapy appear to increase the likelihood of stunning. The stunning effect of early-absorbed radiation from the therapy should also be considered. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Parental Involvement in Cognitive Behavior Therapy for Children with Anxiety Disorders: 3-Year Follow-Up.

    PubMed

    Walczak, Monika; Esbjørn, Barbara H; Breinholst, Sonja; Reinholdt-Dunne, Marie Louise

    2017-06-01

    Parental factors have been linked to childhood anxiety, hence, parental involvement in cognitive behavioral therapy (CBT) for anxious children has been examined. However, findings do not consistently show added effects of parent-enhanced CBT, longitudinal investigations are scarce and long-term effects unclear. In the present study, 40 out of 54 families who, 3 years previously, completed one of two types of CBT treatment: with limited or active parental involvement, were assessed using semi-structured diagnostic interviews. Diagnostic status at 3-years follow-up was compared between groups. Changes in diagnostic status across assessment points: posttreatment, 6-month and 3-year follow-up were analyzed within groups. Diagnostic change from 6-month to 3-year follow-up was compared between groups. Intent-to-treat analyses revealed no significant difference in diagnostic status between groups at 3-year follow-up. Nonetheless, children whose parents actively participated in treatment showed significantly more remission from 6-month to 3-year follow-up than children with limited parental participation.

  20. Protocol investigating the clinical utility of an objective measure of activity and attention (QbTest) on diagnostic and treatment decision-making in children and young people with ADHD-'Assessing QbTest Utility in ADHD' (AQUA): a randomised controlled trial.

    PubMed

    Hall, Charlotte L; Walker, Gemma M; Valentine, Althea Z; Guo, Boliang; Kaylor-Hughes, Catherine; James, Marilyn; Daley, David; Sayal, Kapil; Hollis, Chris

    2014-12-01

    The National Institute for Health and Care Excellence (NICE) guidelines for attention deficit/hyperactivity disorder (ADHD) state that young people need to have access to the best evidence-based care to improve outcome. The current 'gold standard' ADHD diagnostic assessment combines clinical observation with subjective parent, teacher and self-reports. In routine practice, reports from multiple informants may be unavailable or contradictory, leading to diagnostic uncertainty and delay. The addition of objective tests of attention and activity may help reduce diagnostic uncertainty and delays in initiating treatment leading to improved outcomes. This trial investigates whether providing clinicians with an objective report of levels of attention, impulsivity and activity can lead to an earlier, and more accurate, clinical diagnosis and improved patient outcome. This multisite randomised controlled trial will recruit young people (aged 6-17 years old) who have been referred for an ADHD diagnostic assessment at Child and Adolescent Mental Health Services (CAMHS) and Community Paediatric clinics across England. Routine clinical assessment will be augmented by the QbTest, incorporating a continuous performance test (CPT) and infrared motion tracking of activity. The participant will be randomised into one of two study arms: QbOpen (clinician has immediate access to a QbTest report): QbBlind (report is withheld until the study end). Primary outcomes are time to diagnosis and diagnostic accuracy. Secondary outcomes include clinician's diagnostic confidence and routine clinical outcome measures. Cost-effective analysis will be conducted, alongside a qualitative assessment of the feasibility and acceptability of incorporating QbTest in routine practice. The findings from the study will inform commissioners, clinicians and managers about the feasibility, acceptability, clinical utility and cost-effectiveness of incorporating QbTest into routine diagnostic assessment of young people with ADHD. The results will be submitted for publication in peer-reviewed journals. The study has received ethical approval. NCT02209116. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Top