Reliability analysis of the F-8 digital fly-by-wire system
NASA Technical Reports Server (NTRS)
Brock, L. D.; Goodman, H. A.
1981-01-01
The F-8 Digital Fly-by-Wire (DFBW) flight test program intended to provide the technology for advanced control systems, giving aircraft enhanced performance and operational capability is addressed. A detailed analysis of the experimental system was performed to estimated the probabilities of two significant safety critical events: (1) loss of primary flight control function, causing reversion to the analog bypass system; and (2) loss of the aircraft due to failure of the electronic flight control system. The analysis covers appraisal of risks due to random equipment failure, generic faults in design of the system or its software, and induced failure due to external events. A unique diagrammatic technique was developed which details the combinatorial reliability equations for the entire system, promotes understanding of system failure characteristics, and identifies the most likely failure modes. The technique provides a systematic method of applying basic probability equations and is augmented by a computer program written in a modular fashion that duplicates the structure of these equations.
Reliability Growth in Space Life Support Systems
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2014-01-01
A hardware system's failure rate often increases over time due to wear and aging, but not always. Some systems instead show reliability growth, a decreasing failure rate with time, due to effective failure analysis and remedial hardware upgrades. Reliability grows when failure causes are removed by improved design. A mathematical reliability growth model allows the reliability growth rate to be computed from the failure data. The space shuttle was extensively maintained, refurbished, and upgraded after each flight and it experienced significant reliability growth during its operational life. In contrast, the International Space Station (ISS) is much more difficult to maintain and upgrade and its failure rate has been constant over time. The ISS Carbon Dioxide Removal Assembly (CDRA) reliability has slightly decreased. Failures on ISS and with the ISS CDRA continue to be a challenge.
Boermeester, M. A.; Houdijk, A. P.; Meyer, S.; Cuesta, M. A.; Appelmelk, B. J.; Wesdorp, R. I.; Hack, C. E.; Van Leeuwen, P. A.
1995-01-01
The observed increased susceptibility of patients with fulminant hepatic failure for local and systemic infections has been hypothesized to be due to a failure for the hepatic clearance function and subsequent leaking of endogenous endotoxins into the systemic circulation. However, experimental evidence for such a systemic inflammation during liver failure due to endogenous endotoxemia is lacking. Therefore, we designed a study to clarify whether circulating endotoxins due to liver failure could lead to the development of systemic inflammations. In a rat model for liver failure induced by a two-thirds partial hepatectomy, we evaluated the course of circulating tumor necrosis factor and interleukin-6, changes in blood chemistry and hemodynamics, and histopathological changes in the lungs. Partially hepatectomized animals, but not sham-operated animals, demonstrated cardiac failure, increased levels of creatinin and urea, metabolic acidosis, high plasma levels of tumor necrosis factor and interleukin-6, and an influx of PMNs in the lungs-together indicating the development of a systemic inflammatory response. Continuous infusion of recombinant N-terminal bactericidal/permeability-increasing protein (rBPI23), a well described endotoxin-neutralizing protein, prevented these inflammatory reactions. Ex vivo experiments with rat plasma samples confirmed the presence of circulating endotoxins in partially hepatectomized rats as opposed to those treated with rBPI23. Thus, our results indicate that the early phase of liver failure induces a systemic inflammatory response triggered by circulating endotoxins, which can be prevented by perioperative infusion of rBPI23. Images Figure 2 PMID:7485405
Kao, K C; Tsai, Y H; Lin, M C; Huang, C C; Tsao, C Y; Chen, Y C
2000-01-01
A 34-year-old male was admitted to the emergency department with the development of quadriparesis and respiratory failure due to hypokalemia after prolonged glue sniffing. The patient was subsequently given mechanical ventilatory support for respiratory failure. He was weaned from the ventilator 4 days later after potassium replacement. Toluene is an aromatic hydrocarbon found in glues, cements, and solvents. It is known to be toxic to the nervous system, hematopoietic system, and causes acid-base and electrolyte disorders. Acute respiratory failure with hypokalemia and rhabdomyolysis with acute renal failure should be considered as potential events in a protracted glue sniffing.
Collaborative Group Learning and Knowledge Building to Address Information Systems Project Failure
ERIC Educational Resources Information Center
Angelo, Raymond
2011-01-01
Approximately half of the information systems (IS) projects implemented each year are considered failures. These failed projects cost billions of dollars annually. Failures can be due to projects being delivered late, over-budget, abandoned after significant time and resource investment, or failing to achieve desired results. More often than not,…
Spatial correlation analysis of cascading failures: Congestions and Blackouts
Daqing, Li; Yinan, Jiang; Rui, Kang; Havlin, Shlomo
2014-01-01
Cascading failures have become major threats to network robustness due to their potential catastrophic consequences, where local perturbations can induce global propagation of failures. Unlike failures spreading via direct contacts due to structural interdependencies, overload failures usually propagate through collective interactions among system components. Despite the critical need in developing protection or mitigation strategies in networks such as power grids and transportation, the propagation behavior of cascading failures is essentially unknown. Here we find by analyzing our collected data that jams in city traffic and faults in power grid are spatially long-range correlated with correlations decaying slowly with distance. Moreover, we find in the daily traffic, that the correlation length increases dramatically and reaches maximum, when morning or evening rush hour is approaching. Our study can impact all efforts towards improving actively system resilience ranging from evaluation of design schemes, development of protection strategies to implementation of mitigation programs. PMID:24946927
NASA Astrophysics Data System (ADS)
Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook
2016-11-01
Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC-HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC-HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC-HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC-HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.
A review of wiring system safety in space power systems
NASA Technical Reports Server (NTRS)
Stavnes, Mark W.; Hammoud, Ahmad N.
1993-01-01
Wiring system failures have resulted from arc propagation in the wiring harnesses of current aerospace vehicles. These failures occur when the insulation becomes conductive upon the initiation of an arc. In some cases, the conductive path of the carbon arc track displays a high enough resistance such that the current is limited, and therefore may be difficult to detect using conventional circuit protection. Often, such wiring failures are not simply the result of insulation failure, but are due to a combination of wiring system factors. Inadequate circuit protection, unforgiving system designs, and careless maintenance procedures can contribute to a wiring system failure. This paper approaches the problem with respect to the overall wiring system, in order to determine what steps can be taken to improve the reliability, maintainability, and safety of space power systems. Power system technologies, system designs, and maintenance procedures which have led to past wiring system failures will be discussed. New technologies, design processes, and management techniques which may lead to improved wiring system safety will be introduced.
NASA Technical Reports Server (NTRS)
Huynh, Loc C.; Duval, R. W.
1986-01-01
The use of Redundant Asynchronous Multiprocessor System to achieve ultrareliable Fault Tolerant Control Systems shows great promise. The development has been hampered by the inability to determine whether differences in the outputs of redundant CPU's are due to failures or to accrued error built up by slight differences in CPU clock intervals. This study derives an analytical dynamic model of the difference between redundant CPU's due to differences in their clock intervals and uses this model with on-line parameter identification to idenitify the differences in the clock intervals. The ability of this methodology to accurately track errors due to asynchronisity generate an error signal with the effect of asynchronisity removed and this signal may be used to detect and isolate actual system failures.
NASA Technical Reports Server (NTRS)
Holanda, R.; Frause, L. M.
1977-01-01
The reliability of 45 state-of-the-art strain gage systems under full scale engine testing was investigated. The flame spray process was used to install 23 systems on the first fan rotor of a YF-100 engine; the others were epoxy cemented. A total of 56 percent of the systems failed in 11 hours of engine operation. Flame spray system failures were primarily due to high gage resistance, probably caused by high stress levels. Epoxy system failures were principally erosion failures, but only on the concave side of the blade. Lead-wire failures between the blade-to-disk jump and the control room could not be analyzed.
Reliability and cost: A sensitivity analysis
NASA Technical Reports Server (NTRS)
Suich, Ronald C.; Patterson, Richard L.
1991-01-01
In the design phase of a system, how a design engineer or manager choose between a subsystem with .990 reliability and a more costly subsystem with .995 reliability is examined, along with the justification of the increased cost. High reliability is not necessarily an end in itself but may be desirable in order to reduce the expected cost due to subsystem failure. However, this may not be the wisest use of funds since the expected cost due to subsystem failure is not the only cost involved. The subsystem itself may be very costly. The cost of the subsystem nor the expected cost due to subsystem failure should not be considered separately but the total of the two costs should be maximized, i.e., the total of the cost of the subsystem plus the expected cost due to subsystem failure.
Educational Technology Program. Quarterly Technical Summary, 1 March - 31 May 1972.
ERIC Educational Resources Information Center
Frick, Frederick C.
The results of the field trials of the Lincoln Training System (LTS-3) program are summarized in this report. The LTS-3 system was designed to teach basic electronics to Air Force personnel at Kessler Air Force Base, Mississippi. The results indicated that the instructional delays due to system failure were minimal, and those failures were…
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Failure Behavior of Elbows with Local Wall Thinning
NASA Astrophysics Data System (ADS)
Lee, Sung-Ho; Lee, Jeong-Keun; Park, Jai-Hak
Wall thinning defect due to corrosion is one of major aging phenomena in carbon steel pipes in most plant industries, and it results in reducing load carrying capacity of the piping components. A failure test system was set up for real scale elbows containing various simulated wall thinning defects, and monotonic in-plane bending tests were performed under internal pressure to find out the failure behavior of them. The failure behavior of wall-thinned elbows was characterized by the circumferential angle of thinned region and the loading conditions to the piping system.
The Need for Intelligent Control of Space Power Systems
NASA Technical Reports Server (NTRS)
May, Ryan David; Soeder, James F.; Beach, Raymond F.; McNelis, Nancy B.
2013-01-01
As manned spacecraft venture farther from Earth, the need for reliable, autonomous control of vehicle subsystems becomes critical. This is particularly true for the electrical power system which is critical to every other system. Autonomy can not be achieved by simple scripting techniques due to the communication latency times and the difficulty associated with failures (or combinations of failures) that need to be handled in as graceful a manner as possible to ensure system availability. Therefore an intelligent control system must be developed that can respond to disturbances and failures in a robust manner and ensure that critical system loads are served and all system constraints are respected.
A diagnosis system using object-oriented fault tree models
NASA Technical Reports Server (NTRS)
Iverson, David L.; Patterson-Hine, F. A.
1990-01-01
Spaceborne computing systems must provide reliable, continuous operation for extended periods. Due to weight, power, and volume constraints, these systems must manage resources very effectively. A fault diagnosis algorithm is described which enables fast and flexible diagnoses in the dynamic distributed computing environments planned for future space missions. The algorithm uses a knowledge base that is easily changed and updated to reflect current system status. Augmented fault trees represented in an object-oriented form provide deep system knowledge that is easy to access and revise as a system changes. Given such a fault tree, a set of failure events that have occurred, and a set of failure events that have not occurred, this diagnosis system uses forward and backward chaining to propagate causal and temporal information about other failure events in the system being diagnosed. Once the system has established temporal and causal constraints, it reasons backward from heuristically selected failure events to find a set of basic failure events which are a likely cause of the occurrence of the top failure event in the fault tree. The diagnosis system has been implemented in common LISP using Flavors.
Spacecraft Parachute Recovery System Testing from a Failure Rate Perspective
NASA Technical Reports Server (NTRS)
Stewart, Christine E.
2013-01-01
Spacecraft parachute recovery systems, especially those with a parachute cluster, require testing to identify and reduce failures. This is especially important when the spacecraft in question is human-rated. Due to the recent effort to make spaceflight affordable, the importance of determining a minimum requirement for testing has increased. The number of tests required to achieve a mature design, with a relatively constant failure rate, can be estimated from a review of previous complex spacecraft recovery systems. Examination of the Apollo parachute testing and the Shuttle Solid Rocket Booster recovery chute system operation will clarify at which point in those programs the system reached maturity. This examination will also clarify the risks inherent in not performing a sufficient number of tests prior to operation with humans on-board. When looking at complex parachute systems used in spaceflight landing systems, a pattern begins to emerge regarding the need for a minimum amount of testing required to wring out the failure modes and reduce the failure rate of the parachute system to an acceptable level for human spaceflight. Not only a sufficient number of system level testing, but also the ability to update the design as failure modes are found is required to drive the failure rate of the system down to an acceptable level. In addition, sufficient data and images are necessary to identify incipient failure modes or to identify failure causes when a system failure occurs. In order to demonstrate the need for sufficient system level testing prior to an acceptable failure rate, the Apollo Earth Landing System (ELS) test program and the Shuttle Solid Rocket Booster Recovery System failure history will be examined, as well as some experiences in the Orion Capsule Parachute Assembly System will be noted.
Space tug propulsion system failure mode, effects and criticality analysis
NASA Technical Reports Server (NTRS)
Boyd, J. W.; Hardison, E. P.; Heard, C. B.; Orourke, J. C.; Osborne, F.; Wakefield, L. T.
1972-01-01
For purposes of the study, the propulsion system was considered as consisting of the following: (1) main engine system, (2) auxiliary propulsion system, (3) pneumatic system, (4) hydrogen feed, fill, drain and vent system, (5) oxygen feed, fill, drain and vent system, and (6) helium reentry purge system. Each component was critically examined to identify possible failure modes and the subsequent effect on mission success. Each space tug mission consists of three phases: launch to separation from shuttle, separation to redocking, and redocking to landing. The analysis considered the results of failure of a component during each phase of the mission. After the failure modes of each component were tabulated, those components whose failure would result in possible or certain loss of mission or inability to return the Tug to ground were identified as critical components and a criticality number determined for each. The criticality number of a component denotes the number of mission failures in one million missions due to the loss of that component. A total of 68 components were identified as critical with criticality numbers ranging from 1 to 2990.
Central hypothyroidism and its role for cardiovascular risk factors in hypopituitary patients.
Feldt-Rasmussen, Ulla; Klose, Marianne
2016-10-01
Hypothyroidism is characterized by hypometabolism, and may be seen as a part of secondary failure due to pituitary insufficiency or tertiary due to hypothalamic disease. Secondary and tertiary failures are also referred to as central hypothyroidism. Whereas overt primary hypothyroidism has a well-known affection on the heart and cardiovascular system, and may result in cardiac failure, cardiovascular affection is less well recognized in central hypothyroidism. Studies on central hypothyroidism and cardiovascular outcome are few and given the rarity of the diseases often small. Further, there are several limitations given vast difficulties in diagnosing the condition correctly biochemically, and difficulties monitoring the treatment because normal thyroid-pituitary feedback interrelationships are disrupted. The present review summarizes available studies of central adult hypothyroidism and its possible influence on the cardiovascular system, describe differences from primary thyroid failure and seek evidence for performing guidelines for clinical management of this particular thyroid and hypothalamo-pituitary disorder.
A global analysis approach for investigating structural resilience in urban drainage systems.
Mugume, Seith N; Gomez, Diego E; Fu, Guangtao; Farmani, Raziyeh; Butler, David
2015-09-15
Building resilience in urban drainage systems requires consideration of a wide range of threats that contribute to urban flooding. Existing hydraulic reliability based approaches have focused on quantifying functional failure caused by extreme rainfall or increase in dry weather flows that lead to hydraulic overloading of the system. Such approaches however, do not fully explore the full system failure scenario space due to exclusion of crucial threats such as equipment malfunction, pipe collapse and blockage that can also lead to urban flooding. In this research, a new analytical approach based on global resilience analysis is investigated and applied to systematically evaluate the performance of an urban drainage system when subjected to a wide range of structural failure scenarios resulting from random cumulative link failure. Link failure envelopes, which represent the resulting loss of system functionality (impacts) are determined by computing the upper and lower limits of the simulation results for total flood volume (failure magnitude) and average flood duration (failure duration) at each link failure level. A new resilience index that combines the failure magnitude and duration into a single metric is applied to quantify system residual functionality at each considered link failure level. With this approach, resilience has been tested and characterised for an existing urban drainage system in Kampala city, Uganda. In addition, the effectiveness of potential adaptation strategies in enhancing its resilience to cumulative link failure has been tested. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Defense Acquisitions: Assessments of Selected Weapon Programs
2011-03-01
Frequency (UHF) Follow-On ( UFO ) satellite system currently in operation and provide interoperability with legacy terminals. MUOS consists of a...delivery of MUOS capabilities is time-critical due to the operational failures of two UFO satellites. The MUOS program has taken several steps to...launch increased due to the unexpected failures of two UFO satellites. Based on the current health of on-orbit satellites, UHF communication
Identification of Bearing Failure Using Signal Vibrations
NASA Astrophysics Data System (ADS)
Yani, Irsyadi; Resti, Yulia; Burlian, Firmansyah
2018-04-01
Vibration analysis can be used to identify damage to mechanical systems such as journal bearings. Identification of failure can be done by observing the resulting vibration spectrum by measuring the vibration signal occurring in a mechanical system Bearing is one of the engine elements commonly used in mechanical systems. The main purpose of this research is to monitor the bearing condition and to identify bearing failure on a mechanical system by observing the resulting vibration. Data collection techniques based on recordings of sound caused by the vibration of the mechanical system were used in this study, then created a database system based bearing failure due to vibration signal recording sounds on a mechanical system The next step is to group the bearing damage by type based on the databases obtained. The results show the percentage of success in identifying bearing damage is 98 %.
Failure analysis and modeling of a multicomputer system. M.S. Thesis
NASA Technical Reports Server (NTRS)
Subramani, Sujatha Srinivasan
1990-01-01
This thesis describes the results of an extensive measurement-based analysis of real error data collected from a 7-machine DEC VaxCluster multicomputer system. In addition to evaluating basic system error and failure characteristics, we develop reward models to analyze the impact of failures and errors on the system. The results show that, although 98 percent of errors in the shared resources recover, they result in 48 percent of all system failures. The analysis of rewards shows that the expected reward rate for the VaxCluster decreases to 0.5 in 100 days for a 3 out of 7 model, which is well over a 100 times that for a 7-out-of-7 model. A comparison of the reward rates for a range of k-out-of-n models indicates that the maximum increase in reward rate (0.25) occurs in going from the 6-out-of-7 model to the 5-out-of-7 model. The analysis also shows that software errors have the lowest reward (0.2 vs. 0.91 for network errors). The large loss in reward rate for software errors is due to the fact that a large proportion (94 percent) of software errors lead to failure. In comparison, the high reward rate for network errors is due to fast recovery from a majority of these errors (median recovery duration is 0 seconds).
Thorndahl, S; Willems, P
2008-01-01
Failure of urban drainage systems may occur due to surcharge or flooding at specific manholes in the system, or due to overflows from combined sewer systems to receiving waters. To quantify the probability or return period of failure, standard approaches make use of the simulation of design storms or long historical rainfall series in a hydrodynamic model of the urban drainage system. In this paper, an alternative probabilistic method is investigated: the first-order reliability method (FORM). To apply this method, a long rainfall time series was divided in rainstorms (rain events), and each rainstorm conceptualized to a synthetic rainfall hyetograph by a Gaussian shape with the parameters rainstorm depth, duration and peak intensity. Probability distributions were calibrated for these three parameters and used on the basis of the failure probability estimation, together with a hydrodynamic simulation model to determine the failure conditions for each set of parameters. The method takes into account the uncertainties involved in the rainstorm parameterization. Comparison is made between the failure probability results of the FORM method, the standard method using long-term simulations and alternative methods based on random sampling (Monte Carlo direct sampling and importance sampling). It is concluded that without crucial influence on the modelling accuracy, the FORM is very applicable as an alternative to traditional long-term simulations of urban drainage systems.
NASA Astrophysics Data System (ADS)
Kumbhalkar, M. A.; Bhope, D. V.; Vanalkar, A. V.
2016-09-01
The dynamics of the rail vehicle represents a balance between the forces acting between wheel and rail, the inertia forces and the forces exerted by suspension and articulation. Axial loading on helical spring causes vertical deflection at straight track but failures calls to investigate for lateral and longitudinal loading at horizontal and vertical curves respectively. Goods carrying vehicle has the frequent failures of middle axle inner suspension spring calls for investigation. The springs are analyzed for effect of stress concentration due to centripetal force and due to tractive and breaking effort. This paper also discusses shear failure analysis of spring at curvature and at uphill at various speeds for different loading condition analytically and by finite element analysis. Two mass rail vehicle suspension systems have been analyzed for vibration responses analytically using mathematical tool Matlab Simulink and the same will be evaluated using FFT vibration analyzer to find peak resonance in vertical, lateral and longitudinal direction. The results prove that the suspension acquires high repeated load in vertical and lateral direction due to tracking and curving causes maximum stress concentration on middle axle suspension spring as height of this spring is larger than end axle spring in primary suspension system and responsible for failure of middle axle suspension spring due to high stress acquisition.
Structural health monitoring of wind turbine blades : SE 265 Final Project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barkley, W. C.; Jacobs, Laura D.; Rutherford, A. C.
2006-03-23
ACME Wind Turbine Corporation has contacted our dynamic analysis firm regarding structural health monitoring of their wind turbine blades. ACME has had several failures in previous years. Examples are shown in Figure 1. These failures have resulted in economic loss for the company due to down time of the turbines (lost revenue) and repair costs. Blade failures can occur in several modes, which may depend on the type of construction and load history. Cracking and delamination are some typical modes of blade failure. ACME warranties its turbines and wishes to decrease the number of blade failures they have to repairmore » and replace. The company wishes to implement a real time structural health monitoring system in order to better understand when blade replacement is necessary. Because of warranty costs incurred to date, ACME is interested in either changing the warranty period for the blades in question or predicting imminent failure before it occurs. ACME's current practice is to increase the number of physical inspections when blades are approaching the end of their fatigue lives. Implementation of an in situ monitoring system would eliminate or greatly reduce the need for such physical inspections. Another benefit of such a monitoring system is that the life of any given component could be extended since real conditions would be monitored. The SHM system designed for ACME must be able to operate while the wind turbine is in service. This means that wireless communication options will likely be implemented. Because blade failures occur due to cyclic stresses in the blade material, the sensing system will focus on monitoring strain at various points.« less
A servo-controlled canine model of stable severe ischemic left ventricular failure.
Wagner, Richard L; Hood, William B; Howland, Peter A
2009-12-01
Reversible left ventricular failure was produced in conscious dogs by compromise of the coronary circulation. In animals with prior left anterior descending coronary artery occlusion, mean left atrial pressure (LAP) was incorporated into an automatic feedback control system used to inflate a balloon cuff on the circumflex (Cfx) coronary artery. The system could produce stable increases in LAP to 15-20 mm Hg. The dominating system transfer function was the ratio of LAP to balloon volume (BV), which was characterized by a fixed delay (5 s), with LAP/BV = (8e(-jomegatau ))/(0.02 + jomega). The system was stabilized by a phase lead network to reduce oscillations of LAP. A total of seven experiments were conducted in three dogs, and testing of inotropic agents was possible in three experiments under stable conditions with the pump off after an hour or more of operation. Problems encountered were 0.003-0.008 Hz oscillations in LAP in three experiments, which could usually be controlled by reducing the system gain. Late stage ventricular fibrillation occurred in all three animals, but defibrillation was easily accomplished after deflating the Cfx balloon. This system produces reversible left ventricular failure solely due to ischemia, thus closely simulating clinical heart failure due to coronary insufficiency.
[Acute renal failure due to RAAS-inhibitors combined with dehydration].
Scherpbier, Nynke D; de Grauw, Wim J C; Wetzels, Jack F M; Vervoort, Gerald M M
2010-01-01
Two men (61 and 81 years old) with mild impaired kidney function developed acute renal failure due to dehydration combined with the use of inhibitors of the renin-angiotensin-aldosterone system (RAAS). After rehydration, correction of hyperkalaemia and stopping RAAS-inhibition and diuretics, they recovered completely. Many patients using RAAS-inhibitors have impaired renal function. In the case of dehydration due to gastroenteritis or prolonged fever they risk developing acute renal failure. The high risk groups are elderly patients, patients with atherosclerosis or heart failure and those with co-medication of diuretics or NSAIDs. The underlying mechanism is that the normal pathways to protect kidney perfusion in case of hypovolaemia are blocked by the use of RAAS-inhibitors or NSAIDs. In the case of dehydration in patients with chronic kidney disease using RAAS-inhibitors, serum creatinine and potassium levels should be monitored. Temporary discontinuation of RAAS-inhibitors or diuretics is often necessary.
Exploring the Factors of an Enterprise Resource Planning System in a Local Government Organization
ERIC Educational Resources Information Center
Shaw, Bryan T.
2012-01-01
The enterprise resource planning (ERP) system industry accounts for $8.8 billion annually. Enterprise resource planning systems are not performing as expected due to implementation barriers, changes in job responsibilities, and access to information; 50% of all information technology failures are due to the implementation of ERP systems. Guided by…
Stripper foil failure modes and cures at the Spallation Neutron Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cousineau, Sarah M; Galambos, John D; Kim, Sang-Ho
2011-01-01
The Spallation Neutron Source comprises a 1 GeV, 1.4 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the $H^0$ excited states created during the $H^-$ charge exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming $H^-$ beam, which circled around to strike the foilmore » bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.« less
Stripper foil failure modes and cures at the Oak Rdige Spallation Neutron Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plum, M.A.; Raparia, D.; Cousineau, S.M.
2011-03-28
The Oak Ridge Spallation Neutron Source comprises a 1 GeV, 1.5 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H{sup 0} excited states created during the H{sup -} charge-exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H{sup -} beam, which circled aroundmore » to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.« less
Failure analysis and modeling of a VAXcluster system
NASA Technical Reports Server (NTRS)
Tang, Dong; Iyer, Ravishankar K.; Subramani, Sujatha S.
1990-01-01
This paper discusses the results of a measurement-based analysis of real error data collected from a DEC VAXcluster multicomputer system. In addition to evaluating basic system dependability characteristics such as error and failure distributions and hazard rates for both individual machines and for the VAXcluster, reward models were developed to analyze the impact of failures on the system as a whole. The results show that more than 46 percent of all failures were due to errors in shared resources. This is despite the fact that these errors have a recovery probability greater than 0.99. The hazard rate calculations show that not only errors, but also failures occur in bursts. Approximately 40 percent of all failures occur in bursts and involved multiple machines. This result indicates that correlated failures are significant. Analysis of rewards shows that software errors have the lowest reward (0.05 vs 0.74 for disk errors). The expected reward rate (reliability measure) of the VAXcluster drops to 0.5 in 18 hours for the 7-out-of-7 model and in 80 days for the 3-out-of-7 model.
SCADA alarms processing for wind turbine component failure detection
NASA Astrophysics Data System (ADS)
Gonzalez, E.; Reder, M.; Melero, J. J.
2016-09-01
Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.
The hydraulic capacity of deteriorating sewer systems.
Pollert, J; Ugarelli, R; Saegrov, S; Schilling, W; Di Federico, V
2005-01-01
Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Consequences are structural failures, local floods, surface erosion and pollution of receiving waters bodies. European cities spend in the order of five billion Euro per year for wastewater network rehabilitation. This amount is estimated to increase due to network ageing. The project CARE-S (Computer Aided RE-habilitation of Sewer Networks) deals with sewer and storm water networks. The final project goal is to develop integrated software, which provides the most cost-efficient system of maintenance, repair and rehabilitation of sewer networks. Decisions on investments in rehabilitation often have to be made with uncertain information about the structural condition and the hydraulic performance of a sewer system. Because of this, decision-making involves considerable risks. This paper presents the results of research focused on the study of hydraulic effects caused by failures due to temporal decline of sewer systems. Hydraulic simulations are usually carried out by running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections information as dataset to catalogue principal types of failures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was carried out through the comparison of laboratory experiences and 3D simulations results. Those parameters could be the input of 1D commercial models instead of the default values commonly inserted.
Volterrani, Maurizio; Iellamo, Ferdinando; Senni, Michele; Piepoli, Massimo F
2017-01-01
In heart failure, in addition to the renin-angiotensin-aldosterone system and sympathetic nervous system, the natriuretic peptide (NP) system plays a fundamental role among compensating mechanisms. The NPs undergo rapid enzymatic degradation that limits their vasorelaxant, natriuretic, and diuretic actions. Degradation of NPs is partially due to the action of neprilysin, which is a membrane-bound endopeptidase found in many tissues. This article summarizes recent findings on a new natriuretic peptide-enhancing drug and their implication for future pharmacological treatment of patients suffering from heart failure with reduced ejection fraction. Copyright © 2016. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Idris, N. H.; Salim, N. A.; Othman, M. M.; Yasin, Z. M.
2018-03-01
This paper presents the Evolutionary Programming (EP) which proposed to optimize the training parameters for Artificial Neural Network (ANN) in predicting cascading collapse occurrence due to the effect of protection system hidden failure. The data has been collected from the probability of hidden failure model simulation from the historical data. The training parameters of multilayer-feedforward with backpropagation has been optimized with objective function to minimize the Mean Square Error (MSE). The optimal training parameters consists of the momentum rate, learning rate and number of neurons in first hidden layer and second hidden layer is selected in EP-ANN. The IEEE 14 bus system has been tested as a case study to validate the propose technique. The results show the reliable prediction of performance validated through MSE and Correlation Coefficient (R).
NASA Technical Reports Server (NTRS)
Fragola, Joseph R.; Maggio, Gaspare; Frank, Michael V.; Gerez, Luis; Mcfadden, Richard H.; Collins, Erin P.; Ballesio, Jorge; Appignani, Peter L.; Karns, James J.
1995-01-01
The application of the probabilistic risk assessment methodology to a Space Shuttle environment, particularly to the potential of losing the Shuttle during nominal operation is addressed. The different related concerns are identified and combined to determine overall program risks. A fault tree model is used to allocate system probabilities to the subsystem level. The loss of the vehicle due to failure to contain energetic gas and debris, to maintain proper propulsion and configuration is analyzed, along with the loss due to Orbiter, external tank failure, and landing failure or error.
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
Ouyang, Min; Tian, Hui; Wang, Zhenghua; Hong, Liu; Mao, Zijun
2017-01-17
This article studies a general type of initiating events in critical infrastructures, called spatially localized failures (SLFs), which are defined as the failure of a set of infrastructure components distributed in a spatially localized area due to damage sustained, while other components outside the area do not directly fail. These failures can be regarded as a special type of intentional attack, such as bomb or explosive assault, or a generalized modeling of the impact of localized natural hazards on large-scale systems. This article introduces three SLFs models: node centered SLFs, district-based SLFs, and circle-shaped SLFs, and proposes a SLFs-induced vulnerability analysis method from three aspects: identification of critical locations, comparisons of infrastructure vulnerability to random failures, topologically localized failures and SLFs, and quantification of infrastructure information value. The proposed SLFs-induced vulnerability analysis method is finally applied to the Chinese railway system and can be also easily adapted to analyze other critical infrastructures for valuable protection suggestions. © 2017 Society for Risk Analysis.
Atalar, Ata C; Tunalı, Onur; Erşen, Ali; Kapıcıoğlu, Mehmet; Sağlam, Yavuz; Demirhan, Mehmet S
2017-01-01
In intraarticular distal humerus fractures, internal fixation with double plates is the gold standard treatment. However the optimal plate configuration is not clear in the literature. The aim of this study was to compare the biomechanical stability of the parallel and the orthogonal anatomical locking plating systems in intraarticular distal humerus fractures in artificial humerus models. Intraarticular distal humerus fracture (AO13-C2) with 5 mm metaphyseal defect was created in sixteen artificial humeral models. Models were fixed with either orthogonal or parallel plating systems with locking screws (Acumed elbow plating systems). Both systems were tested for their stiffness with loads in axial compression, varus, valgus, anterior and posterior bending. Then plastic deformation after cyclic loading in posterior bending and load to failure in posterior bending were tested. The failure mechanisms of all the samples were observed. Stiffness values in every direction were not significantly different among the orthogonal and the parallel plating groups. There was no statistical difference between the two groups in plastic deformation values (0.31 mm-0.29 mm) and load to failure tests in posterior bending (372.4 N-379.7 N). In the orthogonal plating system most of the failures occurred due to the proximal shaft fracture, whereas in the parallel plating system failure occurred due to the shift of the most distal screw in proximal fragment. Our study showed that both plating systems had similar biomechanical stabilities when anatomic plates with distal locking screws were used in intraarticular distal humerus fractures in artificial humerus models. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
[Pathophysiology of respiratory muscle weakness].
Windisch, W
2008-03-01
The respiratory system consists of two parts which can be impaired independently from each other, the lungs and the respiratory pump. The latter is a complex system covering different anatomic structures: the breathing centre, the peripheral nervous system, the respiratory muscles, and the thorax. According to this complexity several underlying conditions can cause insufficiency of the respiratory pump, i. e. ventilatory failure. Disturbances of the breathing centre, different neuromuscular disorders, impairments of the mechanics, such as thoracic deformities or hyperinflation, and airway obstruction are example conditions responsible for ventilatory failure. Main characteristic of ventilatory failure is the occurrence of hypercapnia which is in contrast to pulmonary failure where diffusion disturbances typically not cause hypercapnia. Both acute and chronic ventilatory failure presenting with hypercapnia can develop. In acute ventilatory failure respiratory acidosis develops, but in chronic respiratory failure pH is normalized as a consequence of metabolic retention of bicarbonate. However, acute on chronic ventilatory failure can present with a combined picture, i. e. elevated bicarbonate levels, acidosis, and often severe hypercapnia. Clinical signs such as tachypnea, features of the underlying disease or hypercapnia are important diagnostic tools in addition to the measurement of pressures generated by the respiratory muscles. Non-invasive and widely available techniques, such as the assessment of the maximal ins- and expiratory mouth pressures (PImax, PEmax), should be used as screening instruments, but the reliability of these measurements is reduced due to the volitional character of the tests and due to the impossibility to define normal values. Inspiratory pressures can be assessed more accurately and independently from the patients' effort: with or without the insertion of oesophageal and gastric balloon catheters. However, this technique is more invasive and very complex. It is therefore restricted to centres with scientific aims.
NASA Technical Reports Server (NTRS)
Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.
2010-01-01
The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions called the Low Impact Docking System (LIDS). A candidate LIDS main interface seal design is a composite assembly of silicone elastomer seals vacuum molded into grooves in an electroless nickel plated aluminum retainer. The strength of the silicone-tometal bond is a critical consideration for the new system, especially due to the presence of small areas of disbond created during the molding process. In the work presented herein, seal-to-retainer bonds of subscale seal specimens with different sizes of intentional disbond were destructively tensile tested. Nominal specimens without intentional disbonds were also tested. Tension was applied either uniformly on the entire seal circumference or locally in one short circumferential length. Bond failure due to uniform tension produced a wide scatter of observable failure modes and measured load-displacement behaviors. Although the preferable failure mode for the seal-to-retainer bond is cohesive failure of the elastomer material, the dominant observed failure mode under the uniform loading condition was found to be the less desirable adhesive failure of the bond in question. The uniform tension case results did not show a correlation between disbond size and bond strength. Localized tension was found to produce failure either as immediate tearing of the elastomer material outside the bond region or as complete peel-out of the seal in one piece. The obtained results represent a valuable benchmark for comparison in the future between adhesion loads under various separation conditions and composite seal bond strength.
77 FR 40830 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-11
... proposed AD was prompted by reports of ram air turbine (RAT) pump failure. This proposed AD would require..., an A330 aeroplane experienced a RAT [ram air turbine] pump failure, as a result of which, the green hydraulic system could not be fully pressurized. Investigations concluded that this malfunction was due to...
NASA Astrophysics Data System (ADS)
Kuller, W. G.; Hanifen, D. W.
1982-07-01
Exoatmospheric detonations of nuclear weapons produce a broad spectrum of effects which can prevent operational space missions from being successfully accomplished. The spacecraft may be exposed to the prompt radiation from the detonations which can cause upset or burnout of critical mission components through Transient Radiation Effects on Electronics (TREE) or System Generated Electromagnetic Pulse (SGEMP). Continual exposure to the trapped radiation environment may cause component failure due to total dose or Electron Caused EMP (ECEMP). Satellite links to ground and airborne terminals are subject to serious degradation due to signal absorption and scintillation. The ground data stations and lines of communications are subject to failure from the broad range effects of high-altitude EMP.
Future research directions to improve fistula maturation and reduce access failure
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J.; Santana, Jeans M.; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R.; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-01-01
With the increasing prevalence of end stage renal disease there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes, in the setting of uremia, systemic inflammation, oxidative stress and preexistent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis, as well as development of neointimal hyperplasia (NIH) that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to NIH involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure, based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure requires a multidisciplinary approach involving nephrologists, vascular surgeons and interventional radiologists, allowing careful patient selection and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. PMID:28779782
Future research directions to improve fistula maturation and reduce access failure.
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J; Santana, Jeans M; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-12-01
With the increasing prevalence of end-stage renal disease, there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis, but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes in the setting of uremia, systemic inflammation, oxidative stress, and pre-existent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis and development of neointimal hyperplasia that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to neointimal hyperplasia involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure require a multidisciplinary approach involving nephrologists, vascular surgeons, and interventional radiologists, careful patient selection, and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Frady, Greg; Nesman, Thomas; Zoladz, Thomas; Szabo, Roland
2010-01-01
For many years, the capabilities to determine the root-cause failure of component failures have been limited to the analytical tools and the state of the art data acquisition systems. With this limited capability, many anomalies have been resolved by adding material to the design to increase robustness without the ability to determine if the design solution was satisfactory until after a series of expensive test programs were complete. The risk of failure and multiple design, test, and redesign cycles were high. During the Space Shuttle Program, many crack investigations in high energy density turbomachines, like the SSME turbopumps and high energy flows in the main propulsion system, have led to the discovery of numerous root-cause failures and anomalies due to the coexistences of acoustic forcing functions, structural natural modes, and a high energy excitation, such as an edge tone or shedding flow, leading the technical community to understand many of the primary contributors to extremely high frequency high cycle fatique fluid-structure interaction anomalies. These contributors have been identified using advanced analysis tools and verified using component and system tests during component ground tests, systems tests, and flight. The structural dynamics and fluid dynamics communities have developed a special sensitivity to the fluid-structure interaction problems and have been able to adjust and solve these problems in a time effective manner to meet budget and schedule deadlines of operational vehicle programs, such as the Space Shuttle Program over the years.
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.; Patterson-Hine, Ann; Iverson, David
1997-01-01
Fault diagnosis in large-scale systems that are products of modern technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.
1997-01-01
Fault diagnosis in large-scale systems that are products of modem technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
Simulation Assisted Risk Assessment: Blast Overpressure Modeling
NASA Technical Reports Server (NTRS)
Lawrence, Scott L.; Gee, Ken; Mathias, Donovan; Olsen, Michael
2006-01-01
A probabilistic risk assessment (PRA) approach has been developed and applied to the risk analysis of capsule abort during ascent. The PRA is used to assist in the identification of modeling and simulation applications that can significantly impact the understanding of crew risk during this potentially dangerous maneuver. The PRA approach is also being used to identify the appropriate level of fidelity for the modeling of those critical failure modes. The Apollo launch escape system (LES) was chosen as a test problem for application of this approach. Failure modes that have been modeled and/or simulated to date include explosive overpressure-based failure, explosive fragment-based failure, land landing failures (range limits exceeded either near launch or Mode III trajectories ending on the African continent), capsule-booster re-contact during separation, and failure due to plume-induced instability. These failure modes have been investigated using analysis tools in a variety of technical disciplines at various levels of fidelity. The current paper focuses on the development and application of a blast overpressure model for the prediction of structural failure due to overpressure, including the application of high-fidelity analysis to predict near-field and headwinds effects.
NASA Technical Reports Server (NTRS)
Westrup, R. W.
1971-01-01
The application of general design approaches for preventing failures due to repeated load cycles is briefly discussed. Program objective, mission requirements, and structural design criteria are summarized. Discrete structural elements and associated sections were selected for detailed strength, fatigue, and fracture mechanics investigations.
Complications of varicella zoster.
Gücüyener, Kivilcim; Citak, Elvan Cağlar; Elli, Murat; Serdaroğlu, Ayse; Citak, Funda Erkasar
2002-02-01
Primary infection with varicella zoster is characterzed by a generalized vesicular rash usually without significant systemic illness. Encephalitis, pneumonitis, pancreatitis, nephritis, Reye and Guillan-Barre syndrome transvers myelitis, myocarditis have been reported before, but there is not any case having all these system to be involved during the same infection in a sequential manner ending up with multiorgan failure. We wanted to represent 21-month-old boy had a multiorgan failure due to varicella zoster infection.
Section 7 reactor incident file general information from 1945
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1969-01-10
At 0308 on January 10, 1966, both B and C Reactors ``scrammed`` due to an electrical fault on Line C2-L8 caused by a raccoon coming in contact with the 13-8 KV line on top of transformer No. 2 at 182-B Building. Line C2-L8 relayed out at the 151-B Building. Details of the occurrence at 151-B are covered in the attachment. C-Reactor scrammed due to reduced voltage on the pressure monitor system. The reduction in voltage caused the auxiliary relays of the pressure monitor ground detector to open, de-energizing the end result relays PSR and PSRA. The safety circuit trip identificationmore » system displayed ``Pressure Monitor`` and ``Ground Detector.`` B-Reactor scrammed by a power failure signal from 190-B Building. The power failure relays for pump numbers 1 and 3 opened due to these pumps contributing power to the fault. The power failure relays at 190-B remained open long enough for the end result relays PF and PFA to open. Since these relays are timed delayed, 0.26 seconds, the power failure relays must have remained open at least that long. At the 190-B Building the steam turbines started due to the power failure relays for pump numbers 1 and 3 opening. The main process pumps remained stable and continued to supply normal flow to the reactor. Pumps were tripped from the line at 182-B and 183-B Buildings. The surge suppressors cycled normally and the turbine export pumps started as a result of low export line pressure. No power equipment was affected in C Area.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgess, Robert M.; Post, Matthew B.; Buttner, William J.
Pressure relief devices (PRDs ) are used to protect high pressure systems from burst failure caused by overpressurization. Codes and standards require the use of PRDs for the safe design of many pressurized systems. These systems require high reliability due to the risks associated with a burst failure. Hydrogen service can increase the risk of PRD failure due to material property degradation caused by hydrogen attack. The National Renewable Energy Laboratory (NREL) has conducted an accelerated life test on a conventional spring loaded PRD. Based on previous failures in the field, the nozzles specific to these PRDs are of particularmore » interest. A nozzle in a PRD is a small part that directs the flow of fluid toward the sealing surface to maintain the open state of the valve once the spring force is overcome. The nozzle in this specific PRD is subjected to the full tensile force of the fluid pressure. These nozzles are made from 440C material, which is a type of hardened steel that is commonly chosen for high pressure applications because of its high strength properties. In a hydrogen environment, however, 440C is considered a worst case material since hydrogen attack results in a loss of almost all ductility and thus 440C is prone to fatigue and material failure. Accordingly, 440C is not recommended for hydrogen service. Conducting an accelerated life test on a PRD with 440C material provides information on necessary and sufficient conditions required to produce crack initiation and failure. The accelerated life test also provides information on other PRD failure modes that are somewhat statistically random in nature.« less
Failure Scenarios and Mitigations for the BABAR Superconducting Solenoid
NASA Astrophysics Data System (ADS)
Thompson, EunJoo; Candia, A.; Craddock, W. W.; Racine, M.; Weisend, J. G.
2006-04-01
The cryogenic department at the Stanford Linear Accelerator Center is responsible for the operation, troubleshooting, and upgrade of the 1.5 Tesla superconducting solenoid detector for the BABAR B-factory experiment. Events that disable the detector are rare but significantly impact the availability of the detector for physics research. As a result, a number of systems and procedures have been developed over time to minimize the downtime of the detector, for example improved control systems, improved and automatic backup systems, and spares for all major components. Together they can prevent or mitigate many of the failures experienced by the utilities, mechanical systems, controls and instrumentation. In this paper we describe various failure scenarios, their effect on the detector, and the modifications made to mitigate the effects of the failure. As a result of these modifications the reliability of the detector has increased significantly with only 3 shutdowns of the detector due to cryogenics systems over the last 2 years.
Kim, Dong Seong; Park, Jong Sou
2014-01-01
It is important to assess availability of virtualized systems in IT business infrastructures. Previous work on availability modeling and analysis of the virtualized systems used a simplified configuration and assumption in which only one virtual machine (VM) runs on a virtual machine monitor (VMM) hosted on a physical server. In this paper, we show a comprehensive availability model using stochastic reward nets (SRN). The model takes into account (i) the detailed failures and recovery behaviors of multiple VMs, (ii) various other failure modes and corresponding recovery behaviors (e.g., hardware faults, failure and recovery due to Mandelbugs and aging-related bugs), and (iii) dependency between different subcomponents (e.g., between physical host failure and VMM, etc.) in a virtualized servers system. We also show numerical analysis on steady state availability, downtime in hours per year, transaction loss, and sensitivity analysis. This model provides a new finding on how to increase system availability by combining both software rejuvenations at VM and VMM in a wise manner. PMID:25165732
Cascades in interdependent flow networks
NASA Astrophysics Data System (ADS)
Scala, Antonio; De Sanctis Lucentini, Pier Giorgio; Caldarelli, Guido; D'Agostino, Gregorio
2016-06-01
In this manuscript, we investigate the abrupt breakdown behavior of coupled distribution grids under load growth. This scenario mimics the ever-increasing customer demand and the foreseen introduction of energy hubs interconnecting the different energy vectors. We extend an analytical model of cascading behavior due to line overloads to the case of interdependent networks and find evidence of first order transitions due to the long-range nature of the flows. Our results indicate that the foreseen increase in the couplings between the grids has two competing effects: on the one hand, it increases the safety region where grids can operate without withstanding systemic failures; on the other hand, it increases the possibility of a joint systems' failure.
Holm, Niels; Müller, Andreas; Zbinden, Rainer
2017-04-01
A Medtronic MICRA transcatheter pacing system (Medtronic, Minneapolis, MN, USA) was implanted in an 86-year-old patient with sick sinus syndrome and left bundle branch block after transfemoral aortic valve implantation. During implantation she developed a persistent complete heart block due to manipulation with the large-bore delivery catheter. Two weeks later, acute pacemaker dysfunction occurred due to massive increase of pacing threshold and impedance without obvious pacemaker dislocation or myocardial perforation. Recurrent capture failure was seen with pacing output set at 5 V/1.0 ms. Hence, microdislocation or fixation of the tines in the right ventricular trabeculae has to be assumed. © 2016 Wiley Periodicals, Inc.
Reliability and cost analysis methods
NASA Technical Reports Server (NTRS)
Suich, Ronald C.
1991-01-01
In the design phase of a system, how does a design engineer or manager choose between a subsystem with .990 reliability and a more costly subsystem with .995 reliability? When is the increased cost justified? High reliability is not necessarily an end in itself but may be desirable in order to reduce the expected cost due to subsystem failure. However, this may not be the wisest use of funds since the expected cost due to subsystem failure is not the only cost involved. The subsystem itself may be very costly. We should not consider either the cost of the subsystem or the expected cost due to subsystem failure separately but should minimize the total of the two costs, i.e., the total of the cost of the subsystem plus the expected cost due to subsystem failure. This final report discusses the Combined Analysis of Reliability, Redundancy, and Cost (CARRAC) methods which were developed under Grant Number NAG 3-1100 from the NASA Lewis Research Center. CARRAC methods and a CARRAC computer program employ five models which can be used to cover a wide range of problems. The models contain an option which can include repair of failed modules.
Acute Right Ventricle Failure in the Intensive Care Unit: Assessment and Management.
Hrymak, Carmen; Strumpher, Johann; Jacobsohn, Eric
2017-01-01
Caring for the critically ill patient with acute right ventricle (RV) failure is a diagnostic and management challenge. A thorough understanding of normal RV anatomy and physiology is essential to manage RV failure. Despite the fact that the RV is essentially a volume chamber that ejects into a low-pressure system, the left ventricle contributes significantly to RV function through maintenance of the transseptal gradient (TSG). Preserving systemic mean arterial pressure maintains the TSG and RV perfusion. Various pathological states cause acute RV failure by decreasing the TSG and RV perfusion and/or increasing pulmonary vascular resistance. Early diagnosis prevents rapid progression of RV failure due to the "double hit phenomenon," which is acute intra-abdominal multiple organ system failure as a result of a reduced blood pressure and elevated central venous pressure. Management includes hemodynamic support and reversal of the precipitating cause through optimizing RV rate and rhythm, determining ideal RV filling pressure, reducing RV afterload through nonpharmacologic and pharmacological means, and selecting the appropriate RV inotrope or mechanical support. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Management of the Severely Mentally Ill and Its Effects on Homeland Security
2011-09-01
system to the criminal justice system as it relates to its effect on prison overcrowding and attempts at combating prison and jail radicalization...alcohol and/or illegal drugs ; failure to stay on prescribed medications or failure to find effective treatment; also inability to stay employed due...or 30 years ago. Meth related Psychosis. Increased drug use. In ability for family’s to deal with the mental health person and put the burden on
Podbregar, M; Voga, G; Horvat, M; Zuran, I; Krivec, B; Skale, R; Pareznik, R
1999-01-01
The first dose of angiotensin-converting enzyme (ACE) inhibitors may trigger a considerable fall of blood pressure in chronic heart failure. The response may be dose-related. To determine hemodynamic and systemic oxygenation effects of low-dose enalaprilat, we administered intravenous enalaprilat (0.004 mg/kg) as bolus (group B) or continuous 1-hour infusion (group C) in 20 patients with congestive heart failure due to ischemic heart disease with acute decompensation refractory to inotropic, vasodilator and diuretic therapy. Hemodynamic and systemic oxygenation variables were recorded at baseline (+0 min), +30, +60, +120, +180, and +360 min after the start of intervention. Mean arterial pressure (MAP) (p < 0. 001), mean pulmonary artery pressure (MPAP) (p < 0.001), pulmonary artery occlusion pressure (PAOP) (p < 0.001), oxygen extraction ratio (ER) (p < 0.026) decreased regardless of enalaprilat application. Compared to group B, there was in group C prolonged decrease of MAP, MPAP, PAOP, ER and increase of pulmonary artery oxyhemoglobin saturation in regard to baseline values. Cardiac index, heart rate, central venous pressure and oxygen consumption index did not change. A low dose of intravenous enalaprilat (0.004 mg/kg) can be used to safely improve hemodynamics and systemic oxygenation in congestive heart failure due to ischemic heart disease with acute refractory decompensation.
Preventing Spacecraft Failures Due to Tribological Problems
NASA Technical Reports Server (NTRS)
Fusaro, Robert L.
2001-01-01
Many mechanical failures that occur on spacecraft are caused by tribological problems. This publication presents a study that was conducted by the author on various preventatives, analyses, controls and tests (PACTs) that could be used to prevent spacecraft mechanical system failure. A matrix is presented in the paper that plots tribology failure modes versus various PACTs that should be performed before a spacecraft is launched in order to insure success. A strawman matrix was constructed by the author and then was sent out to industry and government spacecraft designers, scientists and builders of spacecraft for their input. The final matrix is the result of their input. In addition to the matrix, this publication describes the various PACTs that can be performed and some fundamental knowledge on the correct usage of lubricants for spacecraft applications. Even though the work was done specifically to prevent spacecraft failures the basic methodology can be applied to other mechanical system areas.
Behavior of tunnel form buildings under quasi-static cyclic lateral loading
Yuksel, S.B.; Kalkan, E.
2007-01-01
In this paper, experimental investigations on the inelastic seismic behavior of tunnel form buildings (i.e., box-type or panel systems) are presented. Two four-story scaled building specimens were tested under quasi-static cyclic lateral loading in longitudinal and transverse directions. The experimental results and supplemental finite element simulations collectively indicate that lightly reinforced structural walls of tunnel form buildings may exhibit brittle flexural failure under seismic action. The global tension/compression couple triggers this failure mechanism by creating pure axial tension in outermost shear-walls. This type of failure takes place due to rupturing of longitudinal reinforcement without crushing of concrete, therefore is of particular interest in emphasizing the mode of failure that is not routinely considered during seismic design of shear-wall dominant structural systems.
Explosive Event in MON-3 Oxidizer System Resulting from Pressure Transducer Failure
NASA Technical Reports Server (NTRS)
Baker, David L.; Reynolds, Michael; Anderson, John
2006-01-01
In 2003, a Druck(Registered Trademark) pressure transducer failed catastrophically in a test system circulating nitrogen tetroxide at NASA Johnson Space Center White Sands Test Facility. The cause of the explosion was not immediately obvious since the wetted areas of the pressure transducer were constructed of materials compatible with nitrogen tetroxide. Chemical analysis of the resulting residue and a materials analysis of the diaphragm and its weld zones were used to determine the chain of events that led to the catastrophic failure. Due to excessive dynamic pressure loading in the test system, the diaphragm in the pressure transducer suffered cyclic failure and allowed the silicon oil located behind the isolation diaphragm to mix with the nitrogen tetroxide. The reaction between these two chemicals formed a combination of 2,4-di and 2,4,6-trinitrophenol, which are shock sensitive explosives that caused the failure of the pressure transducer. Further research indicated numerous manufacturers offer similar pressure transducers with silicone oil separated from the test fluid by a thin stainless steel isolation diaphragm. Caution must be exercised when purchasing a pressure transducer for a particular system to avoid costly failures and test system contamination.
Modelling Wind Turbine Failures based on Weather Conditions
NASA Astrophysics Data System (ADS)
Reder, Maik; Melero, Julio J.
2017-11-01
A large proportion of the overall costs of a wind farm is directly related to operation and maintenance (O&M) tasks. By applying predictive O&M strategies rather than corrective approaches these costs can be decreased significantly. Here, especially wind turbine (WT) failure models can help to understand the components’ degradation processes and enable the operators to anticipate upcoming failures. Usually, these models are based on the age of the systems or components. However, latest research shows that the on-site weather conditions also affect the turbine failure behaviour significantly. This study presents a novel approach to model WT failures based on the environmental conditions to which they are exposed to. The results focus on general WT failures, as well as on four main components: gearbox, generator, pitch and yaw system. A penalised likelihood estimation is used in order to avoid problems due to for example highly correlated input covariates. The relative importance of the model covariates is assessed in order to analyse the effect of each weather parameter on the model output.
Predicting the Lifetime of Dynamic Networks Experiencing Persistent Random Attacks.
Podobnik, Boris; Lipic, Tomislav; Horvatic, Davor; Majdandzic, Antonio; Bishop, Steven R; Eugene Stanley, H
2015-09-21
Estimating the critical points at which complex systems abruptly flip from one state to another is one of the remaining challenges in network science. Due to lack of knowledge about the underlying stochastic processes controlling critical transitions, it is widely considered difficult to determine the location of critical points for real-world networks, and it is even more difficult to predict the time at which these potentially catastrophic failures occur. We analyse a class of decaying dynamic networks experiencing persistent failures in which the magnitude of the overall failure is quantified by the probability that a potentially permanent internal failure will occur. When the fraction of active neighbours is reduced to a critical threshold, cascading failures can trigger a total network failure. For this class of network we find that the time to network failure, which is equivalent to network lifetime, is inversely dependent upon the magnitude of the failure and logarithmically dependent on the threshold. We analyse how permanent failures affect network robustness using network lifetime as a measure. These findings provide new methodological insight into system dynamics and, in particular, of the dynamic processes of networks. We illustrate the network model by selected examples from biology, and social science.
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Lee, Kang N.; Miller, Robert A.
2002-01-01
Plasma-sprayed ZrO2-8wt%Y2O3 and mullite+BSAS/Si multilayer thermal and environmental barrier coating (TBC-EBC) systems on SiC/SiC ceramic matrix composite (CMC) substrates were thermally cyclic tested under high thermal gradients using a laser high-heat-flux rig in conjunction with furnace exposure in water-vapor environments. Coating sintering and interface damage were assessed by monitoring the real-time thermal conductivity changes during the laser heat-flux tests and by examining the microstructural changes after exposure. Sintering kinetics of the coating systems were also independently characterized using a dilatometer. It was found that the coating failure involved both the time-temperature dependent sintering and the cycle frequency dependent cyclic fatigue processes. The water vapor environments not only facilitated the initial coating conductivity increases due to enhanced sintering and interface reaction, but also promoted later conductivity reductions due to the accelerated coating cracking and delamination. The failure mechanisms of the coating systems are also discussed based on the cyclic test results and are correlated to the sintering and thermal stress behavior under the thermal gradient test conditions.
NASA Astrophysics Data System (ADS)
Belapurkar, Rohit K.
Future aircraft engine control systems will be based on a distributed architecture, in which, the sensors and actuators will be connected to the Full Authority Digital Engine Control (FADEC) through an engine area network. Distributed engine control architecture will allow the implementation of advanced, active control techniques along with achieving weight reduction, improvement in performance and lower life cycle cost. The performance of a distributed engine control system is predominantly dependent on the performance of the communication network. Due to the serial data transmission policy, network-induced time delays and sampling jitter are introduced between the sensor/actuator nodes and the distributed FADEC. Communication network faults and transient node failures may result in data dropouts, which may not only degrade the control system performance but may even destabilize the engine control system. Three different architectures for a turbine engine control system based on a distributed framework are presented. A partially distributed control system for a turbo-shaft engine is designed based on ARINC 825 communication protocol. Stability conditions and control design methodology are developed for the proposed partially distributed turbo-shaft engine control system to guarantee the desired performance under the presence of network-induced time delay and random data loss due to transient sensor/actuator failures. A fault tolerant control design methodology is proposed to benefit from the availability of an additional system bandwidth and from the broadcast feature of the data network. It is shown that a reconfigurable fault tolerant control design can help to reduce the performance degradation in presence of node failures. A T-700 turbo-shaft engine model is used to validate the proposed control methodology based on both single input and multiple-input multiple-output control design techniques.
Application of Improved Genetic Algorithm to Service Restoration Problem for Distribution Systems
NASA Astrophysics Data System (ADS)
Michibata, Ikuo; Aoki, Hidenori
The problem of recovery from power-system failures is the problem of handling operations that make it possible to supply power from other lines in response to power-system failures or construction by switching between the opened and closed states of sectionalizing switches. Considerable research has already been conducted with regard to this issue. This paper addresses the issue of determining target systems for final recovery in cases when some sections remain subject to power failure (i.e., sound bank capacity < load capacity). For this purpose, intersection is conducted only for parameters within such power-failure sections. In such research, calculations are implemented by setting a value of 2 to the sectionalizing switches of a single parameter. In addition, when the state of a sound section changes due to mutation improvements, the method of simultaneously changing the selected points and neighboring sectionalizing switches is applied. It is clear that the proposed method, consisting of conventional GA only, is superior in terms of average fitness values.
2008-09-01
publication has been reproduced directly from material supplied by RTO or the authors. Published September 2008 Copyright © RTO/NATO 2008 All Rights...requirements are met at each level within the composed system, a chain of belief is formed which provides assurance that the composed system is in...FAILURE OF AIR-CONDITIONING x 12 – LOSS OF POWER SUPPLY x 13 – FAILURE OF TELECOMMUNICATION EQUIPMENT x 4 – Disturbance Due to
NASA Technical Reports Server (NTRS)
Hark, Frank; Britton, Paul; Ring, Rob; Novack, Steven D.
2016-01-01
Common Cause Failures (CCFs) are a known and documented phenomenon that defeats system redundancy. CCFS are a set of dependent type of failures that can be caused by: system environments; manufacturing; transportation; storage; maintenance; and assembly, as examples. Since there are many factors that contribute to CCFs, the effects can be reduced, but they are difficult to eliminate entirely. Furthermore, failure databases sometimes fail to differentiate between independent and CCF (dependent) failure and data is limited, especially for launch vehicles. The Probabilistic Risk Assessment (PRA) of NASA's Safety and Mission Assurance Directorate at Marshal Space Flight Center (MFSC) is using generic data from the Nuclear Regulatory Commission's database of common cause failures at nuclear power plants to estimate CCF due to the lack of a more appropriate data source. There remains uncertainty in the actual magnitude of the common cause risk estimates for different systems at this stage of the design. Given the limited data about launch vehicle CCF and that launch vehicles are a highly redundant system by design, it is important to make design decisions to account for a range of values for independent and CCFs. When investigating the design of the one-out-of-two component redundant system for launch vehicles, a response surface was constructed to represent the impact of the independent failure rate versus a common cause beta factor effect on a system's failure probability. This presentation will define a CCF and review estimation calculations. It gives a summary of reduction methodologies and a review of examples of historical CCFs. Finally, it presents the response surface and discusses the results of the different CCFs on the reliability of a one-out-of-two system.
NASA Technical Reports Server (NTRS)
Hark, Frank; Britton, Paul; Ring, Rob; Novack, Steven D.
2015-01-01
Common Cause Failures (CCFs) are a known and documented phenomenon that defeats system redundancy. CCFS are a set of dependent type of failures that can be caused by: system environments; manufacturing; transportation; storage; maintenance; and assembly, as examples. Since there are many factors that contribute to CCFs, the effects can be reduced, but they are difficult to eliminate entirely. Furthermore, failure databases sometimes fail to differentiate between independent and CCF (dependent) failure and data is limited, especially for launch vehicles. The Probabilistic Risk Assessment (PRA) of NASA's Safety and Mission Assurance Directorate at Marshall Space Flight Center (MFSC) is using generic data from the Nuclear Regulatory Commission's database of common cause failures at nuclear power plants to estimate CCF due to the lack of a more appropriate data source. There remains uncertainty in the actual magnitude of the common cause risk estimates for different systems at this stage of the design. Given the limited data about launch vehicle CCF and that launch vehicles are a highly redundant system by design, it is important to make design decisions to account for a range of values for independent and CCFs. When investigating the design of the one-out-of-two component redundant system for launch vehicles, a response surface was constructed to represent the impact of the independent failure rate versus a common cause beta factor effect on a system's failure probability. This presentation will define a CCF and review estimation calculations. It gives a summary of reduction methodologies and a review of examples of historical CCFs. Finally, it presents the response surface and discusses the results of the different CCFs on the reliability of a one-out-of-two system.
14 CFR 23.1123 - Exhaust system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Exhaust system. 23.1123 Section 23.1123 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... prevent failure due to expansion by operating temperatures. (b) Each exhaust system must be supported to...
14 CFR 23.1123 - Exhaust system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Exhaust system. 23.1123 Section 23.1123 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... prevent failure due to expansion by operating temperatures. (b) Each exhaust system must be supported to...
14 CFR 23.1123 - Exhaust system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Exhaust system. 23.1123 Section 23.1123 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... prevent failure due to expansion by operating temperatures. (b) Each exhaust system must be supported to...
14 CFR 23.1123 - Exhaust system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Exhaust system. 23.1123 Section 23.1123 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... prevent failure due to expansion by operating temperatures. (b) Each exhaust system must be supported to...
14 CFR 23.1123 - Exhaust system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Exhaust system. 23.1123 Section 23.1123 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... prevent failure due to expansion by operating temperatures. (b) Each exhaust system must be supported to...
ERIC Educational Resources Information Center
Herron, Sherry; Gandy, Rex; Ye, Ningjun; Syed, Nasser
2012-01-01
A unique aspect of the implementation of a computer algebra system (CAS) at a comprehensive university in the U.S. allowed us to compare the student success and failure rates to the traditional method of teaching college algebra. Due to space limitations, the university offered sections of both CAS and traditional simultaneously and, upon…
Reliability measurement during software development. [for a multisensor tracking system
NASA Technical Reports Server (NTRS)
Hecht, H.; Sturm, W. A.; Trattner, S.
1977-01-01
During the development of data base software for a multi-sensor tracking system, reliability was measured. The failure ratio and failure rate were found to be consistent measures. Trend lines were established from these measurements that provided good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.
Fatigue life prediction of liquid rocket engine combustor with subscale test verification
NASA Astrophysics Data System (ADS)
Sung, In-Kyung
Reusable rocket systems such as the Space Shuttle introduced a new era in propulsion system design for economic feasibility. Practical reusable systems require an order of magnitude increase in life. To achieve this improved methods are needed to assess failure mechanisms and to predict life cycles of rocket combustor. A general goal of the research was to demonstrate the use of subscale rocket combustor prototype in a cost-effective test program. Life limiting factors and metal behaviors under repeated loads were surveyed and reviewed. The life prediction theories are presented, with an emphasis on studies that used subscale test hardware for model validation. From this review, low cycle fatigue (LCF) and creep-fatigue interaction (ratcheting) were identified as the main life limiting factors of the combustor. Several life prediction methods such as conventional and advanced viscoplastic models were used to predict life cycle due to low cycle thermal stress, transient effects, and creep rupture damage. Creep-fatigue interaction and cyclic hardening were also investigated. A prediction method based on 2D beam theory was modified using 3D plate deformation theory to provide an extended prediction method. For experimental validation two small scale annular plug nozzle thrusters were designed, built and tested. The test article was composed of a water-cooled liner, plug annular nozzle and 200 psia precombustor that used decomposed hydrogen peroxide as the oxidizer and JP-8 as the fuel. The first combustor was tested cyclically at the Advanced Propellants and Combustion Laboratory at Purdue University. Testing was stopped after 140 cycles due to an unpredicted failure mechanism due to an increasing hot spot in the location where failure was predicted. A second combustor was designed to avoid the previous failure, however, it was over pressurized and deformed beyond repair during cold-flow test. The test results are discussed and compared to the analytical and numerical predictions. A detailed comparison was not performed, however, due to the lack of test data resulting from a failure of the test article. Some theoretical and experimental aspects such as fin effect and round corner were found to reduce the discrepancy between prediction and test results.
40 CFR 280.11 - Interim prohibition for deferred UST systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...
40 CFR 280.11 - Interim prohibition for deferred UST systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...
40 CFR 280.11 - Interim prohibition for deferred UST systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...
40 CFR 280.11 - Interim prohibition for deferred UST systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...
40 CFR 280.11 - Interim prohibition for deferred UST systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...
Pituitary function in chronic heart failure in the elderly.
Ceda, G P; Dall'Aglio, E; Salimbeni, I; Rocci, A; Mazzoni, S; Corradi, F; Cattadori, E; Visioli, S; Banchini, A; Ceresini, G; Valenti, G; Hoffman, A R
2002-01-01
Heart failure is a complex syndrome characterized by the activation of hemodynamic, immunologic and neurohormonal systems, which have beneficial effects in the short run, but will ultimately lead to secondary end-organ damage with worsening of LV remodeling and subsequent cardiac decompensation. A very important role seems to be played by modifications of the pituitary hormone systems. Due to the neurohormonal activation there is an increase in the activity in the renin angiotensin system, in the adrenergic nervous system, and in the cytokine system. In heart failure there is a decrease in many anabolic hormones, such as a decrease of GH and IGF-I, of DHEA/DHEAS with normal or increased F, and a decrease of LH and sex steroids, resulting in an important catabolic drive, capable of contributing to the development of cardiac failure and to sarcopenia and/or cachexia, frequently observed in the advanced stages of the disease. However, these hormone alterations have been described in relatively young patients with chronic heart failure, since the mean age of all the subjects studied was of about 60 yr and none of the studies have specifically addressed this issue in the very old patients, who represent the largest portion of population affected by this pathological condition. The role of hormone replacement therapy needs to be verified in a population of elderly patients with heart failure.
Alwan, Faris M; Baharum, Adam; Hassan, Geehan S
2013-01-01
The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.
Alwan, Faris M.; Baharum, Adam; Hassan, Geehan S.
2013-01-01
The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter and shape parameters and . Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models. PMID:23936346
Renal function monitoring in heart failure – what is the optimal frequency? A narrative review
Wright, David; Devonald, Mark Alexander John; Pirmohamed, Munir
2017-01-01
The second most common cause of hospitalization due to adverse drug reactions in the UK is renal dysfunction due to diuretics, particularly in patients with heart failure, where diuretic therapy is a mainstay of treatment regimens. Therefore, the optimal frequency for monitoring renal function in these patients is an important consideration for preventing renal failure and hospitalization. This review looks at the current evidence for optimal monitoring practices of renal function in patients with heart failure according to national and international guidelines on the management of heart failure (AHA/NICE/ESC/SIGN). Current guidance of renal function monitoring is in large part based on expert opinion, with a lack of clinical studies that have specifically evaluated the optimal frequency of renal function monitoring in patients with heart failure. Furthermore, there is variability between guidelines, and recommendations are typically nonspecific. Safer prescribing of diuretics in combination with other antiheart failure treatments requires better evidence for frequency of renal function monitoring. We suggest developing more personalized monitoring rather than from the current medication‐based guidance. Such flexible clinical guidelines could be implemented using intelligent clinical decision support systems. Personalized renal function monitoring would be more effective in preventing renal decline, rather than reacting to it. PMID:28901643
Reliability analysis based on the losses from failures.
Todinov, M T
2006-04-01
The conventional reliability analysis is based on the premise that increasing the reliability of a system will decrease the losses from failures. On the basis of counterexamples, it is demonstrated that this is valid only if all failures are associated with the same losses. In case of failures associated with different losses, a system with larger reliability is not necessarily characterized by smaller losses from failures. Consequently, a theoretical framework and models are proposed for a reliability analysis, linking reliability and the losses from failures. Equations related to the distributions of the potential losses from failure have been derived. It is argued that the classical risk equation only estimates the average value of the potential losses from failure and does not provide insight into the variability associated with the potential losses. Equations have also been derived for determining the potential and the expected losses from failures for nonrepairable and repairable systems with components arranged in series, with arbitrary life distributions. The equations are also valid for systems/components with multiple mutually exclusive failure modes. The expected losses given failure is a linear combination of the expected losses from failure associated with the separate failure modes scaled by the conditional probabilities with which the failure modes initiate failure. On this basis, an efficient method for simplifying complex reliability block diagrams has been developed. Branches of components arranged in series whose failures are mutually exclusive can be reduced to single components with equivalent hazard rate, downtime, and expected costs associated with intervention and repair. A model for estimating the expected losses from early-life failures has also been developed. For a specified time interval, the expected losses from early-life failures are a sum of the products of the expected number of failures in the specified time intervals covering the early-life failures region and the expected losses given failure characterizing the corresponding time intervals. For complex systems whose components are not logically arranged in series, discrete simulation algorithms and software have been created for determining the losses from failures in terms of expected lost production time, cost of intervention, and cost of replacement. Different system topologies are assessed to determine the effect of modifications of the system topology on the expected losses from failures. It is argued that the reliability allocation in a production system should be done to maximize the profit/value associated with the system. Consequently, a method for setting reliability requirements and reliability allocation maximizing the profit by minimizing the total cost has been developed. Reliability allocation that maximizes the profit in case of a system consisting of blocks arranged in series is achieved by determining for each block individually the reliabilities of the components in the block that minimize the sum of the capital, operation costs, and the expected losses from failures. A Monte Carlo simulation based net present value (NPV) cash-flow model has also been proposed, which has significant advantages to cash-flow models based on the expected value of the losses from failures per time interval. Unlike these models, the proposed model has the capability to reveal the variation of the NPV due to different number of failures occurring during a specified time interval (e.g., during one year). The model also permits tracking the impact of the distribution pattern of failure occurrences and the time dependence of the losses from failures.
Defense Acquisitions: Assessments of Selected Weapon Programs
2013-03-01
UHF) Follow-On ( UFO ) satellite system currently in operation and provide interoperability with legacy terminals. MUOS consists of a network of...MUOS satellites remain important due to the past operational failures of two UFO satellites and predicted end-of-life of on-orbit UFO satellites...Despite the delay and earlier, unexpected failures of two UFO satellites, the required availability level of UHF communication capabilities has been
14 CFR 25.981 - Fuel tank ignition prevention.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.981 Fuel tank... system where catastrophic failure could occur due to ignition of fuel or vapors. This must be shown by... established, as necessary, to prevent development of ignition sources within the fuel tank system pursuant to...
14 CFR 25.981 - Fuel tank ignition prevention.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.981 Fuel tank... system where catastrophic failure could occur due to ignition of fuel or vapors. This must be shown by... established, as necessary, to prevent development of ignition sources within the fuel tank system pursuant to...
14 CFR 25.981 - Fuel tank ignition prevention.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.981 Fuel tank... system where catastrophic failure could occur due to ignition of fuel or vapors. This must be shown by... established, as necessary, to prevent development of ignition sources within the fuel tank system pursuant to...
14 CFR 25.981 - Fuel tank ignition prevention.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.981 Fuel tank... system where catastrophic failure could occur due to ignition of fuel or vapors. This must be shown by... established, as necessary, to prevent development of ignition sources within the fuel tank system pursuant to...
14 CFR 25.981 - Fuel tank ignition prevention.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.981 Fuel tank... system where catastrophic failure could occur due to ignition of fuel or vapors. This must be shown by... established, as necessary, to prevent development of ignition sources within the fuel tank system pursuant to...
How to Predict Oral Rehydration Failure in Children With Gastroenteritis.
Geurts, Dorien; Steyerberg, Ewout W; Moll, Henriëtte; Oostenbrink, Rianne
2017-11-01
Oral rehydration is the standard in most current guidelines for young children with acute gastroenteritis (AGE). Failure of oral rehydration can complicate the disease course, leading to morbidity due to severe dehydration. We aimed to identify prognostic factors of oral rehydration failure in children with AGE. A prospective, observational study was performed at the Emergency department, Erasmus Medical Centre, Rotterdam, The Netherlands, 2010-2012, including 802 previously healthy children, ages 1 month to 5 years with AGE. Failure of oral rehydration was defined by secondary rehydration by a nasogastric tube, or hospitalization or revisit for dehydration within 72 hours after initial emergency department visit. We observed 167 (21%) failures of oral rehydration in a population of 802 children with AGE (median 1.03 years old, interquartile range 0.4-2.1; 60% boys). In multivariate logistic regression analysis, independent predictors for failure of oral rehydration were a higher Manchester Triage System urgency level, abnormal capillary refill time, and a higher clinical dehydration scale score. Early recognition of young children with AGE at risk of failure of oral rehydration therapy is important, as emphasized by the 21% therapy failure in our population. Associated with oral rehydration failure are higher Manchester Triage System urgency level, abnormal capillary refill time, and a higher clinical dehydration scale score.
NASA Technical Reports Server (NTRS)
Onwubiko, Chin-Yere; Onyebueke, Landon
1996-01-01
Structural failure is rarely a "sudden death" type of event, such sudden failures may occur only under abnormal loadings like bomb or gas explosions and very strong earthquakes. In most cases, structures fail due to damage accumulated under normal loadings such as wind loads, dead and live loads. The consequence of cumulative damage will affect the reliability of surviving components and finally causes collapse of the system. The cumulative damage effects on system reliability under time-invariant loadings are of practical interest in structural design and therefore will be investigated in this study. The scope of this study is, however, restricted to the consideration of damage accumulation as the increase in the number of failed components due to the violation of their strength limits.
2012-01-01
Introduction The Molecular Adsorbent Recycling System (MARS) is used to treat patients with liver failure. Observational data suggest that citrate anticoagulation during MARS is feasible. Comparative studies on the optimal anticoagulation regimen during MARS are lacking. The aim of the current study was to evaluate two heparin-free anticoagulation regimens. Methods We performed a prospective randomized open-label crossover study of regional citrate anticoagulation against no anticoagulation. Ten patients (age 55 ± 11 years) with liver failure undergoing MARS treatment were included. The primary endpoint was completion of MARS sessions. Secondary endpoints included treatment efficacy and safety. Longevity of MARS treatment was plotted as a Kaplan-Meier estimate. Fisher's exact test was used for contingency table analysis. Results Of a total of 27 6-hour sessions, four sessions had to be terminated prematurely, three due to occlusive clotting of the extracorporeal circuit and one due to uncontrollable bleeding from the vascular access site. All four events occurred in the group without anticoagulation. Between group comparison demonstrated citrate anticoagulation to significantly increase the likelihood of completed MARS treatment (Fisher's exact test, P 0.04). This translates into higher bilirubin reduction ratios when citrate was applied (reduction ratio 0.25 vs. 0.15, P 0.02). Systemic ionized calcium concentrations were significantly reduced during citrate anticoagulation (P < 0.001) but remained within a safe range. We observed no major adverse events. Conclusions Regional citrate anticoagulation in patients with liver failure is feasible. Citrate anticoagulation provides superior patency of the extracorporeal circuit. Avoidance of anticoagulation during MARS results in significant loss of treatment efficacy, due to treatment downtime. Additional studies are required to identify the optimal anticoagulation regimen for extracorporeal circulation in patients with liver failure. PMID:22305273
An overview of fatigue failures at the Rocky Flats Wind System Test Center
NASA Technical Reports Server (NTRS)
Waldon, C. A.
1981-01-01
Potential small wind energy conversion (SWECS) design problems were identified to improve product quality and reliability. Mass produced components such as gearboxes, generators, bearings, etc., are generally reliable due to their widespread uniform use in other industries. The likelihood of failure increases, though, in the interfacing of these components and in SWECS components designed for a specific system use. Problems relating to the structural integrity of such components are discussed and analyzed with techniques currently used in quality assurance programs in other manufacturing industries.
Radionuclide Imaging of Neurohormonal System of the Heart
Chen, Xinyu; Werner, Rudolf A.; Javadi, Mehrbod S.; Maya, Yoshifumi; Decker, Michael; Lapa, Constantin; Herrmann, Ken; Higuchi, Takahiro
2015-01-01
Heart failure is one of the growing causes of death especially in developed countries due to longer life expectancy. Although many pharmacological and instrumental therapeutic approaches have been introduced for prevention and treatment of heart failure, there are still limitations and challenges. Nuclear cardiology has experienced rapid growth in the last few decades, in particular the application of single photon emission computed tomography (SPECT) and positron emission tomography (PET), which allow non-invasive functional assessment of cardiac condition including neurohormonal systems involved in heart failure; its application has dramatically improved the capacity for fundamental research and clinical diagnosis. In this article, we review the current status of applying radionuclide technology in non-invasive imaging of neurohormonal system in the heart, especially focusing on the tracers that are currently available. A short discussion about disadvantages and perspectives is also included. PMID:25825596
Compression failure of angle-ply laminates
NASA Technical Reports Server (NTRS)
Peel, Larry D.; Hyer, Michael W.; Shuart, Mark J.
1991-01-01
The present work deals with modes and mechanisms of failure in compression of angle-ply laminates. Experimental results were obtained from 42 angle-ply IM7/8551-7a specimens with a lay-up of ((plus or minus theta)/(plus or minus theta)) sub 6s where theta, the off-axis angle, ranged from 0 degrees to 90 degrees. The results showed four failure modes, these modes being a function of off-axis angle. Failure modes include fiber compression, inplane transverse tension, inplane shear, and inplane transverse compression. Excessive interlaminar shear strain was also considered as an important mode of failure. At low off-axis angles, experimentally observed values were considerably lower than published strengths. It was determined that laminate imperfections in the form of layer waviness could be a major factor in reducing compression strength. Previously developed linear buckling and geometrically nonlinear theories were used, with modifications and enhancements, to examine the influence of layer waviness on compression response. The wavy layer is described by a wave amplitude and a wave length. Linear elastic stress-strain response is assumed. The geometrically nonlinear theory, in conjunction with the maximum stress failure criterion, was used to predict compression failure and failure modes for the angle-ply laminates. A range of wave length and amplitudes were used. It was found that for 0 less than or equal to theta less than or equal to 15 degrees failure was most likely due to fiber compression. For 15 degrees less than theta less than or equal to 35 degrees, failure was most likely due to inplane transverse tension. For 35 degrees less than theta less than or equal to 70 degrees, failure was most likely due to inplane shear. For theta less than 70 degrees, failure was most likely due to inplane transverse compression. The fiber compression and transverse tension failure modes depended more heavily on wave length than on wave amplitude. Thus using a single parameter, such as a ratio of wave amplitude to wave length, to describe waviness in a laminate would be inaccurate. Throughout, results for AS4/3502, studied previously, are included for comparison. At low off-axis angles, the AS4/3502 material system was found to be less sensitive to layer waviness than IM7/8551-7a. Analytical predictions were also obtained for laminates with waviness in only some of the layers. For this type of waviness, laminate compression strength could also be considered a function of which layers in the laminate were wavy, and where those wavy layers were. Overall, the geometrically nonlinear model correlates well with experimental results.
Mini-Ckpts: Surviving OS Failures in Persistent Memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fiala, David; Mueller, Frank; Ferreira, Kurt Brian
Concern is growing in the high-performance computing (HPC) community on the reliability of future extreme-scale systems. Current efforts have focused on application fault-tolerance rather than the operating system (OS), despite the fact that recent studies have suggested that failures in OS memory are more likely. The OS is critical to a system's correct and efficient operation of the node and processes it governs -- and in HPC also for any other nodes a parallelized application runs on and communicates with: Any single node failure generally forces all processes of this application to terminate due to tight communication in HPC. Therefore,more » the OS itself must be capable of tolerating failures. In this work, we introduce mini-ckpts, a framework which enables application survival despite the occurrence of a fatal OS failure or crash. Mini-ckpts achieves this tolerance by ensuring that the critical data describing a process is preserved in persistent memory prior to the failure. Following the failure, the OS is rejuvenated via a warm reboot and the application continues execution effectively making the failure and restart transparent. The mini-ckpts rejuvenation and recovery process is measured to take between three to six seconds and has a failure-free overhead of between 3-5% for a number of key HPC workloads. In contrast to current fault-tolerance methods, this work ensures that the operating and runtime system can continue in the presence of faults. This is a much finer-grained and dynamic method of fault-tolerance than the current, coarse-grained, application-centric methods. Handling faults at this level has the potential to greatly reduce overheads and enables mitigation of additional fault scenarios.« less
Software dependability in the Tandem GUARDIAN system
NASA Technical Reports Server (NTRS)
Lee, Inhwan; Iyer, Ravishankar K.
1995-01-01
Based on extensive field failure data for Tandem's GUARDIAN operating system this paper discusses evaluation of the dependability of operational software. Software faults considered are major defects that result in processor failures and invoke backup processes to take over. The paper categorizes the underlying causes of software failures and evaluates the effectiveness of the process pair technique in tolerating software faults. A model to describe the impact of software faults on the reliability of an overall system is proposed. The model is used to evaluate the significance of key factors that determine software dependability and to identify areas for improvement. An analysis of the data shows that about 77% of processor failures that are initially considered due to software are confirmed as software problems. The analysis shows that the use of process pairs to provide checkpointing and restart (originally intended for tolerating hardware faults) allows the system to tolerate about 75% of reported software faults that result in processor failures. The loose coupling between processors, which results in the backup execution (the processor state and the sequence of events) being different from the original execution, is a major reason for the measured software fault tolerance. Over two-thirds (72%) of measured software failures are recurrences of previously reported faults. Modeling, based on the data, shows that, in addition to reducing the number of software faults, software dependability can be enhanced by reducing the recurrence rate.
Defense Acquisitions: Assessments of Selected Weapon Programs
2010-03-01
improved availability for small terminals. It is to replace the Ultra High Frequency (UHF) Follow-On ( UFO ) satellite system currently in operation...of MUOS capabilities is time-critical due to the operational failures of two UFO satellites. The MUOS program has taken several steps to address...failures of two UFO satellites. Based on the current health of on-orbit satellites, UHF communication capabilities are predicted to fall below the
Improving the treatment planning and delivery process of Xoft electronic skin brachytherapy.
Manger, Ryan; Rahn, Douglas; Hoisak, Jeremy; Dragojević, Irena
2018-05-14
To develop an improved Xoft electronic skin brachytherapy process and identify areas of further improvement. A multidisciplinary team conducted a failure modes and effects analysis (FMEA) by developing a process map and a corresponding list of failure modes. The failure modes were scored for their occurrence, severity, and detectability, and a risk priority number (RPN) was calculated for each failure mode as the product of occurrence, severity, and detectability. Corrective actions were implemented to address the higher risk failure modes, and a revised process was generated. The RPNs of the failure modes were compared between the initial process and final process to assess the perceived benefits of the corrective actions. The final treatment process consists of 100 steps and 114 failure modes. The FMEA took approximately 20 person-hours (one physician, three physicists, and two therapists) to complete. The 10 most dangerous failure modes had RPNs ranging from 336 to 630. Corrective actions were effective at addressing most failure modes (10 riskiest RPNs ranging from 189 to 310), yet the RPNs were higher than those published for alternative systems. Many of these high-risk failure modes remained due to hardware design limitations. FMEA helps guide process improvement efforts by emphasizing the riskiest steps. Significant risks are apparent when using a Xoft treatment unit for skin brachytherapy due to hardware limitations such as the lack of several interlocks, a short source lifespan, and variability in source output. The process presented in this article is expected to reduce but not eliminate these risks. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Sensor failure detection for jet engines
NASA Technical Reports Server (NTRS)
Beattie, E. C.; Laprad, R. F.; Akhter, M. M.; Rock, S. M.
1983-01-01
Revisions to the advanced sensor failure detection, isolation, and accommodation (DIA) algorithm, developed under the sensor failure detection system program were studied to eliminate the steady state errors due to estimation filter biases. Three algorithm revisions were formulated and one revision for detailed evaluation was chosen. The selected version modifies the DIA algorithm to feedback the actual sensor outputs to the integral portion of the control for the nofailure case. In case of a failure, the estimates of the failed sensor output is fed back to the integral portion. The estimator outputs are fed back to the linear regulator portion of the control all the time. The revised algorithm is evaluated and compared to the baseline algorithm developed previously.
NASA Astrophysics Data System (ADS)
Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong
2014-06-01
Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.
Cognitive Awareness Prototype Development on User Interface Design
ERIC Educational Resources Information Center
Rosli, D'oria Islamiah
2015-01-01
Human error is a crucial problem in manufacturing industries. Due to the misinterpretation of information on interface system design, accidents or death may occur at workplace. Lack of human cognition criteria in interface system design is also one of the contributions to the failure in using the system effectively. Therefore, this paper describes…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
... Order To Mitigate Systemic Risk, Specifically Liquidity Related, Associated With DTC End of Day Net... so, DTC believes it would reduce the systemic risk associated with a liquidity shortfall and would... facilitate the settlement of transactions while limiting systemic risk due to Participant failure. \\4\\ These...
Failure probability analysis of optical grid
NASA Astrophysics Data System (ADS)
Zhong, Yaoquan; Guo, Wei; Sun, Weiqiang; Jin, Yaohui; Hu, Weisheng
2008-11-01
Optical grid, the integrated computing environment based on optical network, is expected to be an efficient infrastructure to support advanced data-intensive grid applications. In optical grid, the faults of both computational and network resources are inevitable due to the large scale and high complexity of the system. With the optical network based distributed computing systems extensive applied in the processing of data, the requirement of the application failure probability have been an important indicator of the quality of application and an important aspect the operators consider. This paper will present a task-based analysis method of the application failure probability in optical grid. Then the failure probability of the entire application can be quantified, and the performance of reducing application failure probability in different backup strategies can be compared, so that the different requirements of different clients can be satisfied according to the application failure probability respectively. In optical grid, when the application based DAG (directed acyclic graph) is executed in different backup strategies, the application failure probability and the application complete time is different. This paper will propose new multi-objective differentiated services algorithm (MDSA). New application scheduling algorithm can guarantee the requirement of the failure probability and improve the network resource utilization, realize a compromise between the network operator and the application submission. Then differentiated services can be achieved in optical grid.
Review article: BK virus in systemic lupus erythematosus.
Gupta, Nirupama; Lawrence, Robert M; Nguyen, Cuong; Modica, Renee F
2015-08-21
BK virus (BKV) is a human polyomavirus with a seroprevalence of 60-80 % in the general population. In renal transplant patients, it is known to cause renal failure, ureteric stenosis and hemorrhagic cystitis. In bone marrow transplant patients, it is evident that BKV can also cause hemorrhagic cystitis along with BK virus nephropathy (BKVN) in the native kidneys, with subsequent renal failure. However, little is known about BVKN in non-transplanted immune-compromised patients, such as systemic lupus erythematosus (SLE) who may have underlying nephritis and have a compromised immune system due to therapy and/or systemic illness. Thus, this article will focus on the clinical aspects of BKV and its association in patients with SLE.
Lee, Cheens; Robinson, Kerin M; Wendt, Kate; Williamson, Dianne
The unimpeded functioning of hospital Health Information Services (HIS) is essential for patient care, clinical governance, organisational performance measurement, funding and research. In an investigation of hospital Health Information Services' preparedness for internal disasters, all hospitals in the state of Victoria with the following characteristics were surveyed: they have a Health Information Service/ Department; there is a Manager of the Health Information Service/Department; and their inpatient capacity is greater than 80 beds. Fifty percent of the respondents have experienced an internal disaster within the past decade, the majority affecting the Health Information Service. The most commonly occurring internal disasters were computer system failure and floods. Two-thirds of the hospitals have internal disaster plans; the most frequently occurring scenarios provided for are computer system failure, power failure and fire. More large hospitals have established back-up systems than medium- and small-size hospitals. Fifty-three percent of hospitals have a recovery plan for internal disasters. Hospitals typically self-rate as having a 'medium' level of internal disaster preparedness. Overall, large hospitals are better prepared for internal disasters than medium and small hospitals, and preparation for disruption of computer systems and medical record services is relatively high on their agendas.
Reliability of lead-calcium automotive batteries in practical operations
NASA Astrophysics Data System (ADS)
Burghoff, H.-G.; Richter, G.
In order to reach a statistically sound conclusion on the suitability of maintenance-free, lead-calcium automotive batteries for practical operations, the failure behaviour of such batteries has been observed in a large-scale experiment carried out by Mercedes Benz AG and Robert Bosch GmbH in different climatic zones of North America. The results show that the average failure behaviour is not significantly different to that of batteries from other manufacturers using other grid alloy systems and operated under otherwise identical conditions; the cumulative failure probability after 30 months is 17%. The principal causes of failure are: (i) early failure: transport damage, filling errors, and short-circuits due to the outer plates being pushed up during plate-block assembly (manufacturing defect); (ii) statistical failure: short-circuits due to growth of positive plates caused by a reduction in the mechanical strength of the cast positive grid as a result of corrosion; (iii) late failure due to an increased occurrence of short-circuits, especially frequent in outer cell facing the engine of the vehicle (subjected to high temperature), and to defects caused by capacity decay. As expected, the batteries exhibit extremely low water loss in each cell. The poor cyclical performance of stationary batteries, caused by acid stratification and well-known from laboratory tests, has no detrimental effect on the batteries in use. After a thorough analysis of the corrosion process, the battery manufacturer changed the grid alloy and the method of its production, and thus limited the corrosion problem with cast lead-calcium grids and with it the possibility of plate growth. The mathematical methods used in this study, and in particular the characteristic factors derived from them, have proven useful for assessing the suitability of automotive batteries.
Implantable Hemodynamic Monitoring for Heart Failure Patients.
Abraham, William T; Perl, Leor
2017-07-18
Rates of heart failure hospitalization remain unacceptably high. Such hospitalizations are associated with substantial patient, caregiver, and economic costs. Randomized controlled trials of noninvasive telemedical systems have failed to demonstrate reduced rates of hospitalization. The failure of these technologies may be due to the limitations of the signals measured. Intracardiac and pulmonary artery pressure-guided management has become a focus of hospitalization reduction in heart failure. Early studies using implantable hemodynamic monitors demonstrated the potential of pressure-based heart failure management, whereas subsequent studies confirmed the clinical utility of this approach. One large pivotal trial proved the safety and efficacy of pulmonary artery pressure-guided heart failure management, showing a marked reduction in heart failure hospitalizations in patients randomized to active pressure-guided management. "Next-generation" implantable hemodynamic monitors are in development, and novel approaches for the use of this data promise to expand the use of pressure-guided heart failure management. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Renal function monitoring in heart failure - what is the optimal frequency? A narrative review.
Al-Naher, Ahmed; Wright, David; Devonald, Mark Alexander John; Pirmohamed, Munir
2018-01-01
The second most common cause of hospitalization due to adverse drug reactions in the UK is renal dysfunction due to diuretics, particularly in patients with heart failure, where diuretic therapy is a mainstay of treatment regimens. Therefore, the optimal frequency for monitoring renal function in these patients is an important consideration for preventing renal failure and hospitalization. This review looks at the current evidence for optimal monitoring practices of renal function in patients with heart failure according to national and international guidelines on the management of heart failure (AHA/NICE/ESC/SIGN). Current guidance of renal function monitoring is in large part based on expert opinion, with a lack of clinical studies that have specifically evaluated the optimal frequency of renal function monitoring in patients with heart failure. Furthermore, there is variability between guidelines, and recommendations are typically nonspecific. Safer prescribing of diuretics in combination with other antiheart failure treatments requires better evidence for frequency of renal function monitoring. We suggest developing more personalized monitoring rather than from the current medication-based guidance. Such flexible clinical guidelines could be implemented using intelligent clinical decision support systems. Personalized renal function monitoring would be more effective in preventing renal decline, rather than reacting to it. © 2017 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.
NASA Technical Reports Server (NTRS)
Mallinak, E. S.
1987-01-01
A wide variety of Space Station functions will be managed via computerized controls. Many of these functions are at the same time very complex and very critical to the operation of the Space Station. The Environmental Control and Life Support System is one group of very complex and critical subsystems which directly affects the ability of the crew to perform their mission. Failure of the Environmental Control and Life Support Subsystems are to be avoided and, in the event of failure, repair must be effected as rapidly as possible. Due to the complex and diverse nature of the subsystems, it is not possible to train the Space Station crew to be experts in the operation of all of the subsystems. By applying the concepts of computer-based expert systems, it may be possible to provide the necessary expertise for these subsystems in dedicated controllers. In this way, an expert system could avoid failures and extend the operating time of the subsystems even in the event of failure of some components, and could reduce the time to repair by being able to pinpoint the cause of a failure when one cannot be avoided.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Ayvazian, Talin; Brodie, Miles; Lingley, Zachary
2018-03-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to catastrophic optical damage (COD), it is especially crucial for space satellite applications to investigate reliability, failure modes, precursor signatures of failure, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we continued our physics of failure investigation by performing long-term life-tests followed by failure mode analysis (FMA) using nondestructive and destructive micro-analytical techniques. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs- AlGaAs strained QW lasers under ACC mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. We first employed electron beam induced current (EBIC) technique to identify failure modes of degraded SM lasers by observing dark line defects. All the SM failures that we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Keywor
Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio
2017-01-01
To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure ( P <0.05). Multivariate logistic regression analysis showed no statistically significant relationship ( P >0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant ( P <0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.
Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D.; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio
2017-01-01
AIM To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P<0.05). Multivariate logistic regression analysis showed no statistically significant relationship (P>0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y. PMID:28393027
Functional correlation approach to operational risk in banking organizations
NASA Astrophysics Data System (ADS)
Kühn, Reimer; Neu, Peter
2003-05-01
A Value-at-Risk-based model is proposed to compute the adequate equity capital necessary to cover potential losses due to operational risks, such as human and system process failures, in banking organizations. Exploring the analogy to a lattice gas model from physics, correlations between sequential failures are modeled by as functionally defined, heterogeneous couplings between mutually supportive processes. In contrast to traditional risk models for market and credit risk, where correlations are described as equal-time-correlations by a covariance matrix, the dynamics of the model shows collective phenomena such as bursts and avalanches of process failures.
TSS-1R Failure Mode Evaluation
NASA Technical Reports Server (NTRS)
Vaughn, Jason A.; McCollum, Matthew B.; Kamenetzky, Rachel R.
1997-01-01
Soon after the break of the tether during the Tethered Satellite System (TSS-1R) mission in February, 1996, a Tiger Team was assembled at the George C. Marshall Space Flight Center to determine the tether failure mode. One possible failure scenario was the Kevlar' strength member of the tether failed because of degradation due to electrical discharge or electrical arcing. During the next several weeks, extensive electrical discharge testing in low vacuum and plasma environments was conducted in an attempt to reproduce the electrical activity recorded by on-board science instruments during the mission. The results of these tests are presented in this paper.
Pharmacological management of chronic heart failure in adults: a review of the literature.
Auty, Richard
2004-03-01
Heart failure is a common, life threatening condition encountered in patients of all ages and in all clinical settings. It may be due to any of a wide variety of causes - in Malawi, cardiomyopathies, hypertension and rheumatic heart disease are probably the commonest causes of heart failure. In more affluent societies, ischaemic heart disease is an important factor. Chronic heart failure (CHF) causes significant morbidity: it reduces exercise capacity, interferes with sleep and produces unsightly and uncomfortable oedema. The syndrome also carries substantial mortatity, worse than that of many malignant tumours: 20 -30% of patients with mild or moderately severe heart failure will die every year if left untreated. The life expectancy of a patient with untreated severe heart failure is only about 6 months. Table 1 explains the symptomatic classification of the severity of heart failure. Objective measurements of cardiac function, such as Left Ventricular Ejection Fraction (LYEF) or chamber filling pressures, correlate poorly with symptoms and New York Heart Association (NYHA) classification. Many of the problems experienced by a patient with heart failure are due to a 'vicious circle' of events in which pathophysiological responses to the falling cardiac output cause further deterioration in cardiac function over time. These responses include ventricular remodeling, neurohumoural activation (increased sympathetic activity; increased atrial natriuretic peptide; increased angiotensin II), increased activity of the renin-angiotensin-aldosterone system (RAAS) causing fluid retention, vasoconstriction and sodium retention. [Table: see text].
Moussawi, A; Derzsy, N; Lin, X; Szymanski, B K; Korniss, G
2017-09-15
Cascading failures are a critical vulnerability of complex information or infrastructure networks. Here we investigate the properties of load-based cascading failures in real and synthetic spatially-embedded network structures, and propose mitigation strategies to reduce the severity of damages caused by such failures. We introduce a stochastic method for optimal heterogeneous distribution of resources (node capacities) subject to a fixed total cost. Additionally, we design and compare the performance of networks with N-stable and (N-1)-stable network-capacity allocations by triggering cascades using various real-world node-attack and node-failure scenarios. We show that failure mitigation through increased node protection can be effectively achieved against single-node failures. However, mitigating against multiple node failures is much more difficult due to the combinatorial increase in possible sets of initially failing nodes. We analyze the robustness of the system with increasing protection, and find that a critical tolerance exists at which the system undergoes a phase transition, and above which the network almost completely survives an attack. Moreover, we show that cascade-size distributions measured in this region exhibit a power-law decay. Finally, we find a strong correlation between cascade sizes induced by individual nodes and sets of nodes. We also show that network topology alone is a weak predictor in determining the progression of cascading failures.
Factors predicting mortality in severe acute pancreatitis.
Compañy, L; Sáez, J; Martínez, J; Aparicio, J R; Laveda, R; Griñó, P; Pérez-Mateo, M
2003-01-01
Acute pancreatitis (AP) is a common disorder in which ensuing serious complications may lead to a fatal outcome in patients. To describe a large series of patients with severe AP (SAP) who were admitted to our hospital and to identify factors predicting mortality. In a retrospective study, all patients with SAP diagnosed between February 1996 and October 2000 according to the Atlanta criteria were studied. Out of a total of 363 AP patients, 67 developed SAP. The mean age of the patients was 69; the commonest etiology was biliary; 55.2% developed necrosis; the commonest systemic complication was respiratory failure (44.7%), followed by acute renal failure (35.8%) and shock (20.9%). A total of 31.3% of the patients died. Factors significantly related to mortality were age, upper digestive tract bleeding, acute renal failure, respiratory failure and shock by univariate analysis. However, pseudocysts seemed to have a protective effect. By multivariate analysis, independent prognostic factors were age, acute renal failure and respiratory failure. Patients with SAP mainly died due to systemic complications, especially acute renal failure and respiratory failure. Necrosis (in the absence or presence of infection) was not correlated with increased mortality. A pseudocyst was found to be a protective factor, probably because the definition itself led to the selection of patients who had survived multiorgan failure. Copyright 2003 S. Karger AG, Basel and IAP
ERIC Educational Resources Information Center
Mohammadi, Hadi
2014-01-01
Use of the Patch Vulnerability Management (PVM) process should be seriously considered for any networked computing system. The PVM process prevents the operating system (OS) and software applications from being attacked due to security vulnerabilities, which lead to system failures and critical data leakage. The purpose of this research is to…
Chawla, Lakhmir S; Herzog, Charles A; Costanzo, Maria Rosa; Tumlin, James; Kellum, John A; McCullough, Peter A; Ronco, Claudio
2014-04-08
Structural heart disease is highly prevalent in patients with chronic kidney disease requiring dialysis. More than 80% of patients with end-stage renal disease (ESRD) are reported to have cardiovascular disease. This observation has enormous clinical relevance because the leading causes of death for patients with ESRD are of cardiovascular disease etiology, including heart failure, myocardial infarction, and sudden cardiac death. The 2 systems most commonly used to classify the severity of heart failure are the New York Heart Association (NYHA) functional classification and the American Heart Association (AHA)/American College of Cardiology (ACC) staging system. With rare exceptions, patients with ESRD who do not receive renal replacement therapy (RRT) develop signs and symptoms of heart failure, including dyspnea and edema due to inability of the severely diseased kidneys to excrete sodium and water. Thus, by definition, nearly all patients with ESRD develop a symptomatology consistent with heart failure if fluid removal by RRT is delayed. Neither the AHA/ACC heart failure staging nor the NYHA functional classification system identifies the variable symptomatology that patients with ESRD experience depending upon whether evaluation occurs before or after fluid removal by RRT. Consequently, the incidence, severity, and outcomes of heart failure in patients with ESRD are poorly characterized. The 11th Acute Dialysis Quality Initiative has identified this issue as a critical unmet need for the proper evaluation and treatment of heart failure in patients with ESRD. We propose a classification schema based on patient-reported dyspnea assessed both pre- and post-ultrafiltration, in conjunction with echocardiography. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Renfroe, Michael B.; Mcdonald, Edward J.; Bradshaw, Kimberly
1988-01-01
The Logistics Asset Tracking System (LATS) devised by NASA contains data on Space Shuttle LRUs that are daily updated to reflect such LRU status changes as repair due to failure or modification due to changing engineering requirements. The implementation of LATS has substantially increased personnel responsiveness, preventing costly delays in Space Shuttle processing and obviating hardware cannibalization. An evaluation is presented of LATS achievements in the direction of an integrated logistical support posture.
STS-114 Engine Cut-off Sensor Anomaly Technical Consultation Report
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Kichak, Robert A.; Ungar, Eugene K.; Cherney, Robert; Rickman, Steve L.
2009-01-01
The NESC consultation team participated in real-time troubleshooting of the Main Propulsion System (MPS) Engine Cutoff (ECO) sensor system failures during STS-114 launch countdown. The team assisted with External Tank (ET) thermal and ECO Point Sensor Box (PSB) circuit analyses, and made real-time inputs to the Space Shuttle Program (SSP) problem resolution teams. Several long-term recommendations resulted. One recommendation was to conduct cryogenic tests of the ECO sensors to validate, or disprove, the theory that variations in circuit impedance due to cryogenic effects on swaged connections within the sensor were the root cause of STS-114 failures.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-25
... To Mitigate Systemic Risk, Specifically Liquidity Related, Associated With DTC End of Day Net Funds... weekend or holiday). In doing so, DTC believes it would reduce the systemic risk associated with a... systemic risk due to Participant failure. \\5\\ These net debit caps are supported by $3.2 billion of...
Study on Flexible Pavement Failures in Soft Soil Tropical Regions
NASA Astrophysics Data System (ADS)
Jayakumar, M.; Chee Soon, Lee
2015-04-01
Road network system experienced rapid upgrowth since ages ago and it started developing in Malaysia during the colonization of British due to its significant impacts in transportation field. Flexible pavement, the major road network in Malaysia, has been deteriorating by various types of distresses which cause descending serviceability of the pavement structure. This paper discusses the pavement condition assessment carried out in Sarawak and Sabah, Malaysia to have design solutions for flexible pavement failures. Field tests were conducted to examine the subgrade strength of existing roads in Sarawak at various failure locations, to assess the impact of subgrade strength on pavement failures. Research outcomes from field condition assessment and subgrade testing showed that the critical causes of pavement failures are inadequate design and maintenance of drainage system and shoulder cross fall, along with inadequate pavement thickness provided by may be assuming the conservative value of soil strength at optimum moisture content, whereas the exiting and expected subgrade strengths at equilibrium moisture content are far below. Our further research shows that stabilized existing recycled asphalt and base materials to use as a sub-base along with bitumen stabilized open graded base in the pavement composition may be a viable solution for pavement failures.
NASA Astrophysics Data System (ADS)
Sun, Zhi; Hu, Xiaozhi; Shi, Shanshan; Guo, Xu; Zhang, Yupeng; Chen, Haoran
2016-10-01
Edge delamination is frequently observed in carbon fiber reinforced plastic (CFRP) laminates after machining, due to the low fracture toughness of the resin interfaces between carbon fiber plies. In this study, the effects of incorporating tough aramid fibers into the brittle CFRP system are quantified by measuring the residual properties of bolted CFRP. By adding short-aramid-fiber interleaves in CFRP laminates, the residual tensile strength have been substantially increased by 14 % for twill-weave laminates and 45 % for unidirectional laminates respectively. Moreover, tensile failure was observed as the major mode of toughened laminates, in contrast to shear failure of plain laminates. The qualitative FEM results agreed well with the experimental results that edge delamination would cause relatively higher shear stress and therefore alter the failure mode from tensile failure to shear failure.
Failure Analysis for Composition of Web Services Represented as Labeled Transition Systems
NASA Astrophysics Data System (ADS)
Nadkarni, Dinanath; Basu, Samik; Honavar, Vasant; Lutz, Robyn
The Web service composition problem involves the creation of a choreographer that provides the interaction between a set of component services to realize a goal service. Several methods have been proposed and developed to address this problem. In this paper, we consider those scenarios where the composition process may fail due to incomplete specification of goal service requirements or due to the fact that the user is unaware of the functionality provided by the existing component services. In such cases, it is desirable to have a composition algorithm that can provide feedback to the user regarding the cause of failure in the composition process. Such feedback will help guide the user to re-formulate the goal service and iterate the composition process. We propose a failure analysis technique for composition algorithms that views Web service behavior as multiple sequences of input/output events. Our technique identifies the possible cause of composition failure and suggests possible recovery options to the user. We discuss our technique using a simple e-Library Web service in the context of the MoSCoE Web service composition framework.
Chen, Qian; Abercrombie, Robert K; Sheldon, Frederick T.
2015-09-23
Industrial Control Systems (ICS) are commonly used in industries such as oil and natural gas, transportation, electric, water and wastewater, chemical, pharmaceutical, pulp and paper, food and beverage, as well as discrete manufacturing (e.g., automotive, aerospace, and durable goods.) SCADA systems are generally used to control dispersed assets using centralized data acquisition and supervisory control.Originally, ICS implementations were susceptible primarily to local threats because most of their components were located in physically secure areas (i.e., ICS components were not connected to IT networks or systems). The trend toward integrating ICS systems with IT networks (e.g., efficiency and the Internet ofmore » Things) provides significantly less isolation for ICS from the outside world thus creating greater risk due to external threats. Albeit, the availability of ICS/SCADA systems is critical to assuring safety, security and profitability. Such systems form the backbone of our national cyber-physical infrastructure.Herein, we extend the concept of mean failure cost (MFC) to address quantifying availability to harmonize well with ICS security risk assessment. This new measure is based on the classic formulation of Availability combined with Mean Failure Cost (MFC). Finally, the metric offers a computational basis to estimate the availability of a system in terms of the loss that each stakeholder stands to sustain as a result of security violations or breakdowns (e.g., deliberate malicious failures).« less
Performance of concatenated Reed-Solomon/Viterbi channel coding
NASA Technical Reports Server (NTRS)
Divsalar, D.; Yuen, J. H.
1982-01-01
The concatenated Reed-Solomon (RS)/Viterbi coding system is reviewed. The performance of the system is analyzed and results are derived with a new simple approach. A functional model for the input RS symbol error probability is presented. Based on this new functional model, we compute the performance of a concatenated system in terms of RS word error probability, output RS symbol error probability, bit error probability due to decoding failure, and bit error probability due to decoding error. Finally we analyze the effects of the noisy carrier reference and the slow fading on the system performance.
Statistical Physics of Rupture in Heterogeneous Media
NASA Astrophysics Data System (ADS)
Sornette, Didier
The damage and fracture of materials are technologically of enormous interest due to their economic and human cost. They cover a wide range of phenomena like cracking of glass, aging of concrete, the failure of fiber networks in the formation of paper and the breaking of a metal bar subject to an external load. Failure of composite systems is of utmost importance in naval, aeronautics and space industry [1]. By the term composite, we refer to materials with heterogeneous microscopic structures and also to assemblages of macroscopic elements forming a super-structure. Chemical and nuclear plants suffer from cracking due to corrosion either of chemical or radioactive origin, aided by thermal and/or mechanical stress.
Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D
2015-07-01
Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.
Gamell, Marc; Teranishi, Keita; Kolla, Hemanth; ...
2017-10-26
In order to achieve exascale systems, application resilience needs to be addressed. Some programming models, such as task-DAG (directed acyclic graphs) architectures, currently embed resilience features whereas traditional SPMD (single program, multiple data) and message-passing models do not. Since a large part of the community's code base follows the latter models, it is still required to take advantage of application characteristics to minimize the overheads of fault tolerance. To that end, this paper explores how recovering from hard process/node failures in a local manner is a natural approach for certain applications to obtain resilience at lower costs in faulty environments.more » In particular, this paper targets enabling online, semitransparent local recovery for stencil computations on current leadership-class systems as well as presents programming support and scalable runtime mechanisms. Also described and demonstrated in this paper is the effect of failure masking, which allows the effective reduction of impact on total time to solution due to multiple failures. Furthermore, we discuss, implement, and evaluate ghost region expansion and cell-to-rank remapping to increase the probability of failure masking. To conclude, this paper shows the integration of all aforementioned mechanisms with the S3D combustion simulation through an experimental demonstration (using the Titan system) of the ability to tolerate high failure rates (i.e., node failures every five seconds) with low overhead while sustaining performance at large scales. In addition, this demonstration also displays the failure masking probability increase resulting from the combination of both ghost region expansion and cell-to-rank remapping.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamell, Marc; Teranishi, Keita; Kolla, Hemanth
In order to achieve exascale systems, application resilience needs to be addressed. Some programming models, such as task-DAG (directed acyclic graphs) architectures, currently embed resilience features whereas traditional SPMD (single program, multiple data) and message-passing models do not. Since a large part of the community's code base follows the latter models, it is still required to take advantage of application characteristics to minimize the overheads of fault tolerance. To that end, this paper explores how recovering from hard process/node failures in a local manner is a natural approach for certain applications to obtain resilience at lower costs in faulty environments.more » In particular, this paper targets enabling online, semitransparent local recovery for stencil computations on current leadership-class systems as well as presents programming support and scalable runtime mechanisms. Also described and demonstrated in this paper is the effect of failure masking, which allows the effective reduction of impact on total time to solution due to multiple failures. Furthermore, we discuss, implement, and evaluate ghost region expansion and cell-to-rank remapping to increase the probability of failure masking. To conclude, this paper shows the integration of all aforementioned mechanisms with the S3D combustion simulation through an experimental demonstration (using the Titan system) of the ability to tolerate high failure rates (i.e., node failures every five seconds) with low overhead while sustaining performance at large scales. In addition, this demonstration also displays the failure masking probability increase resulting from the combination of both ghost region expansion and cell-to-rank remapping.« less
Autonomous diagnostics and prognostics of signal and data distribution systems
NASA Astrophysics Data System (ADS)
Blemel, Kenneth G.
2001-07-01
Wiring is the nervous system of any complex system and is attached to or services nearly every subsystem. Damage to optical wiring systems can cause serious interruptions in communication, command and control systems. Electrical wiring faults and failures due to opens, shorts, and arcing probably result in adverse effects to the systems serviced by the wiring. Abnormalities in a system usually can be detected by monitoring some wiring parameter such as vibration, data activity or power consumption. This paper introduces the mapping of wiring to critical functions during system engineering to automatically define the Failure Modes Effects and Criticality Analysis. This mapping can be used to define the sensory processes needed to perform diagnostics during system engineering. This paper also explains the use of Operational Modes and Criticality Effects Analysis in the development of Sentient Wiring Systems as a means for diagnostic, prognostics and health management of wiring in aerospace and transportation systems.
Analysis of aggregate pier systems for stabilization of subgrade settlement.
DOT National Transportation Integrated Search
2014-12-01
Every year, ODOT undertakes numerous pavement patching/resurfacing projects to repair pavement : distress and structural failure due to soft and/or organic soils constituting the subgrade. Other than the : temporary solution of patching/resurfacing, ...
NASA Astrophysics Data System (ADS)
Lugauer, F. P.; Stiehl, T. H.; Zaeh, M. F.
Modern laser systems are widely used in industry due to their excellent flexibility and high beam intensities. This leads to an increased hazard potential, because conventional laser safety barriers only offer a short protection time when illuminated with high laser powers. For that reason active systems are used more and more to prevent accidents with laser machines. These systems must fulfil the requirements of functional safety, e.g. according to IEC 61508, which causes high costs. The safety provided by common passive barriers is usually unconsidered in this context. In the presented approach, active and passive systems are evaluated from a holistic perspective. To assess the functional safety of hybrid safety systems, the failure probability of passive barriers is analysed and added to the failure probability of the active system.
Stochastic availability analysis of operational data systems in the Deep Space Network
NASA Technical Reports Server (NTRS)
Issa, T. N.
1991-01-01
Existing availability models of standby redundant systems consider only an operator's performance and its interaction with the hardware performance. In the case of operational data systems in the Deep Space Network (DSN), in addition to an operator system interface, a controller reconfigures the system and links a standby unit into the network data path upon failure of the operating unit. A stochastic (Markovian) process technique is used to model and analyze the availability performance and occurrence of degradation due to partial failures are quantitatively incorporated into the model. Exact expressions of the steady state availability and proportion degraded performance measures are derived for the systems under study. The interaction among the hardware, operator, and controller performance parameters and that interaction's effect on data availability are evaluated and illustrated for an operational data processing system.
Product component genealogy modeling and field-failure prediction
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, Caleb; Hong, Yili; Meeker, William Q.
Many industrial products consist of multiple components that are necessary for system operation. There is an abundance of literature on modeling the lifetime of such components through competing risks models. During the life-cycle of a product, it is common for there to be incremental design changes to improve reliability, to reduce costs, or due to changes in availability of certain part numbers. These changes can affect product reliability but are often ignored in system lifetime modeling. By incorporating this information about changes in part numbers over time (information that is readily available in most production databases), better accuracy can bemore » achieved in predicting time to failure, thus yielding more accurate field-failure predictions. This paper presents methods for estimating parameters and predictions for this generational model and a comparison with existing methods through the use of simulation. Our results indicate that the generational model has important practical advantages and outperforms the existing methods in predicting field failures.« less
Product component genealogy modeling and field-failure prediction
King, Caleb; Hong, Yili; Meeker, William Q.
2016-04-13
Many industrial products consist of multiple components that are necessary for system operation. There is an abundance of literature on modeling the lifetime of such components through competing risks models. During the life-cycle of a product, it is common for there to be incremental design changes to improve reliability, to reduce costs, or due to changes in availability of certain part numbers. These changes can affect product reliability but are often ignored in system lifetime modeling. By incorporating this information about changes in part numbers over time (information that is readily available in most production databases), better accuracy can bemore » achieved in predicting time to failure, thus yielding more accurate field-failure predictions. This paper presents methods for estimating parameters and predictions for this generational model and a comparison with existing methods through the use of simulation. Our results indicate that the generational model has important practical advantages and outperforms the existing methods in predicting field failures.« less
Emerging role of liver X receptors in cardiac pathophysiology and heart failure.
Cannon, Megan V; van Gilst, Wiek H; de Boer, Rudolf A
2016-01-01
Liver X receptors (LXRs) are master regulators of metabolism and have been studied for their pharmacological potential in vascular and metabolic disease. Besides their established role in metabolic homeostasis and disease, there is mounting evidence to suggest that LXRs may exert direct beneficial effects in the heart. Here, we aim to provide a conceptual framework to explain the broad mode of action of LXRs and how LXR signaling may be an important local and systemic target for the treatment of heart failure. We discuss the potential role of LXRs in systemic conditions associated with heart failure, such as hypertension, diabetes, and renal and vascular disease. Further, we expound on recent data that implicate a direct role for LXR activation in the heart, for its impact on cardiomyocyte damage and loss due to ischemia, and effects on cardiac hypertrophy, fibrosis, and myocardial metabolism. Taken together, the accumulating evidence supports the notion that LXRs may represent a novel therapeutic target for the treatment of heart failure.
Seto, Emily; Leonard, Kevin J; Cafazzo, Joseph A; Barnsley, Jan; Masino, Caterina; Ross, Heather J
2012-02-10
Previous trials of heart failure telemonitoring systems have produced inconsistent findings, largely due to diverse interventions and study designs. The objectives of this study are (1) to provide in-depth insight into the effects of telemonitoring on self-care and clinical management, and (2) to determine the features that enable successful heart failure telemonitoring. Semi-structured interviews were conducted with 22 heart failure patients attending a heart function clinic who had used a mobile phone-based telemonitoring system for 6 months. The telemonitoring system required the patients to take daily weight and blood pressure readings, weekly single-lead ECGs, and to answer daily symptom questions on a mobile phone. Instructions were sent to the patient's mobile phone based on their physiological values. Alerts were also sent to a cardiologist's mobile phone, as required. All clinicians involved in the study were also interviewed post-trial (N = 5). The interviews were recorded, transcribed, and then analyzed using a conventional content analysis approach. The telemonitoring system improved patient self-care by instructing the patients in real-time how to appropriately modify their lifestyle behaviors. Patients felt more aware of their heart failure condition, less anxiety, and more empowered. Many were willing to partially fund the use of the system. The clinicians were able to manage their patients' heart failure conditions more effectively, because they had physiological data reported to them frequently to help in their decision-making (eg, for medication titration) and were alerted at the earliest sign of decompensation. Essential characteristics of the telemonitoring system that contributed to improved heart failure management included immediate self-care and clinical feedback (ie, teachable moments), how the system was easy and quick to use, and how the patients and clinicians perceived tangible benefits from telemonitoring. Some clinical concerns included ongoing costs of the telemonitoring system and increased clinical workload. A few patients did not want to be watched long-term while some were concerned they might become dependent on the system. The success of a telemonitoring system is highly dependent on its features and design. The essential system characteristics identified in this study should be considered when developing telemonitoring solutions.
Towards Compensation Correctness in Interactive Systems
NASA Astrophysics Data System (ADS)
Vaz, Cátia; Ferreira, Carla
One fundamental idea of service-oriented computing is that applications should be developed by composing already available services. Due to the long running nature of service interactions, a main challenge in service composition is ensuring correctness of failure recovery. In this paper, we use a process calculus suitable for modelling long running transactions with a recovery mechanism based on compensations. Within this setting, we discuss and formally state correctness criteria for compensable processes compositions, assuming that each process is correct with respect to failure recovery. Under our theory, we formally interpret self-healing compositions, that can detect and recover from failures, as correct compositions of compensable processes.
Sensitivity to VSR failure: K pipe break accident
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meichle, R.H.
1969-09-12
Reactor effects of failure of a safety rod to scram can be considered in two major respects: The reduction in total safety system strength which will affect the amount of ``prompt drop`` and subsequent flux decay rate of the average neutron flux-level; and the change in local flux distribution due to the absence of the particular rod which fails to enter the reactor. The purpose of this memorandum is to describe the physical effects involved and to indicate the approximate magnitude of both reactor-wide and localized changes in event of failure of a VSR simultaneous with a K Reactor risermore » accident.« less
Prijic, Sergej; Buchhorn, Reiner; Kosutic, Jovan; Vukomanovic, Vladislav; Prijic, Andreja; Bjelakovic, Bojko; Zdravkovic, Marija
2014-01-01
Numerous prospective randomized clinical trials demonstrated favorable effect of beta-blockers in adults with chronic heart failure. However, effectiveness of beta blockers in pediatric patients with systemic ventricle systolic dysfunction was not recognized sufficiently. Limited number of pediatric patients might be the course of unrecognized carvediolol treatment benefit. Currently, no meta-analysis has examined the impact of carvedilol and conventional therapy on the clinical outcome in children with chronic heart failure due to impaired systemic ventricle systolic function. We have systematically searched the Medline/PubMed and Cochrane Library for the controlled clinical trials that examine carvedilol and standard treatment efficacy in pediatric patients with systemic ventricle systolic dysfunction. Mean differences for continuous variables, odds ratios for dichotomous outcomes, heterogeneity between studies and publication bias were calculated using Cochrane Review Manager (Rev Man 5.2). Total of 8 prospective/observational studies met established criteria. Odds ratio for chronic heart failure related mortality/heart transplantation secondary to carvedilol was 0.52 (95% CI: 0.28-0.97, I(2) = 0%). Our analysis showed that carvedilol could prevent 1 death/ heart transplantation by treating 14 pediatric patients with impaired systemic ventricle systolic function. Meta-analysis demonstrated clinical outcome benefit of carvedilol in children with chronic heart failure.
Prognostics of Power Electronics, Methods and Validation Experiments
NASA Technical Reports Server (NTRS)
Kulkarni, Chetan S.; Celaya, Jose R.; Biswas, Gautam; Goebel, Kai
2012-01-01
Abstract Failure of electronic devices is a concern for future electric aircrafts that will see an increase of electronics to drive and control safety-critical equipment throughout the aircraft. As a result, investigation of precursors to failure in electronics and prediction of remaining life of electronic components is of key importance. DC-DC power converters are power electronics systems employed typically as sourcing elements for avionics equipment. Current research efforts in prognostics for these power systems focuses on the identification of failure mechanisms and the development of accelerated aging methodologies and systems to accelerate the aging process of test devices, while continuously measuring key electrical and thermal parameters. Preliminary model-based prognostics algorithms have been developed making use of empirical degradation models and physics-inspired degradation model with focus on key components like electrolytic capacitors and power MOSFETs (metal-oxide-semiconductor-field-effect-transistor). This paper presents current results on the development of validation methods for prognostics algorithms of power electrolytic capacitors. Particularly, in the use of accelerated aging systems for algorithm validation. Validation of prognostics algorithms present difficulties in practice due to the lack of run-to-failure experiments in deployed systems. By using accelerated experiments, we circumvent this problem in order to define initial validation activities.
Closing the Gap--Information Systems Curriculum and Changing Global Market
ERIC Educational Resources Information Center
Henson, Kerry; Kamal, Mustafa
2010-01-01
The power of outsourcing basic computing technology such as computer programming, database design, customer service operations and system development, to mention a few have changed the conditions of employment in IT. Many of the projects that went off-shore did not perform well due to failure to consider important factors in business dimensions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiCostanzo, D; Ayan, A; Woollard, J
Purpose: To predict potential failures of hardware within the Varian TrueBeam linear accelerator in order to proactively replace parts and decrease machine downtime. Methods: Machine downtime is a problem for all radiation oncology departments and vendors. Most often it is the result of unexpected equipment failure, and increased due to lack of in-house clinical engineering support. Preventative maintenance attempts to assuage downtime, but often is ineffective at preemptively preventing many failure modes such as MLC motor failures, the need to tighten a gantry chain, or the replacement of a jaw motor, among other things. To attempt to alleviate downtime, softwaremore » was developed in house that determines the maximum value of each axis enumerated in the Truebeam trajectory log files. After patient treatments, this data is stored in a SQL database. Microsoft Power BI is used to plot the average maximum error of each day of each machine as a function of time. The results are then correlated with actual faults that occurred at the machine with the help of Varian service engineers. Results: Over the course of six months, 76,312 trajectory logs have been written into the database and plotted in Power BI. Throughout the course of analysis MLC motors have been replaced on three machines due to the early warning of the trajectory log analysis. The service engineers have also been alerted to possible gantry issues on one occasion due to the aforementioned analysis. Conclusion: Analyzing the trajectory log data is a viable and effective early warning system for potential failures of the TrueBeam linear accelerator. With further analysis and tightening of the tolerance values used to determine a possible imminent failure, it should be possible to pinpoint future issues more thoroughly and for more axes of motion.« less
Physiology of respiratory disturbances in muscular dystrophies
Lo Mauro, Antonella
2016-01-01
Muscular dystrophy is a group of inherited myopathies characterised by progressive skeletal muscle wasting, including of the respiratory muscles. Respiratory failure, i.e. when the respiratory system fails in its gas exchange functions, is a common feature in muscular dystrophy, being the main cause of death, and it is a consequence of lung failure, pump failure or a combination of the two. The former is due to recurrent aspiration, the latter to progressive weakness of respiratory muscles and an increase in the load against which they must contract. In fact, both the resistive and elastic components of the work of breathing increase due to airway obstruction and chest wall and lung stiffening, respectively. The respiratory disturbances in muscular dystrophy are restrictive pulmonary function, hypoventilation, altered thoracoabdominal pattern, hypercapnia, dyspnoea, impaired regulation of breathing, inefficient cough and sleep disordered breathing. They can be present at different rates according to the type of muscular dystrophy and its progression, leading to different onset of each symptom, prognosis and degree of respiratory involvement. Key points A common feature of muscular dystrophy is respiratory failure, i.e. the inability of the respiratory system to provide proper oxygenation and carbon dioxide elimination. In the lung, respiratory failure is caused by recurrent aspiration, and leads to hypoxaemia and hypercarbia. Ventilatory failure in muscular dystrophy is caused by increased respiratory load and respiratory muscles weakness. Respiratory load increases in muscular dystrophy because scoliosis makes chest wall compliance decrease, atelectasis and fibrosis make lung compliance decrease, and airway obstruction makes airway resistance increase. The consequences of respiratory pump failure are restrictive pulmonary function, hypoventilation, altered thoracoabdominal pattern, hypercapnia, dyspnoea, impaired regulation of breathing, inefficient cough and sleep disordered breathing. Educational aims To understand the mechanisms leading to respiratory disturbances in patients with muscular dystrophy. To understand the impact of respiratory disturbances in patients with muscular dystrophy. To provide a brief description of the main forms of muscular dystrophy with their respiratory implications. PMID:28210319
Physiology of respiratory disturbances in muscular dystrophies.
Lo Mauro, Antonella; Aliverti, Andrea
2016-12-01
Muscular dystrophy is a group of inherited myopathies characterised by progressive skeletal muscle wasting, including of the respiratory muscles. Respiratory failure, i.e . when the respiratory system fails in its gas exchange functions, is a common feature in muscular dystrophy, being the main cause of death, and it is a consequence of lung failure, pump failure or a combination of the two. The former is due to recurrent aspiration, the latter to progressive weakness of respiratory muscles and an increase in the load against which they must contract. In fact, both the resistive and elastic components of the work of breathing increase due to airway obstruction and chest wall and lung stiffening, respectively. The respiratory disturbances in muscular dystrophy are restrictive pulmonary function, hypoventilation, altered thoracoabdominal pattern, hypercapnia, dyspnoea, impaired regulation of breathing, inefficient cough and sleep disordered breathing. They can be present at different rates according to the type of muscular dystrophy and its progression, leading to different onset of each symptom, prognosis and degree of respiratory involvement. A common feature of muscular dystrophy is respiratory failure, i.e. the inability of the respiratory system to provide proper oxygenation and carbon dioxide elimination.In the lung, respiratory failure is caused by recurrent aspiration, and leads to hypoxaemia and hypercarbia.Ventilatory failure in muscular dystrophy is caused by increased respiratory load and respiratory muscles weakness.Respiratory load increases in muscular dystrophy because scoliosis makes chest wall compliance decrease, atelectasis and fibrosis make lung compliance decrease, and airway obstruction makes airway resistance increase.The consequences of respiratory pump failure are restrictive pulmonary function, hypoventilation, altered thoracoabdominal pattern, hypercapnia, dyspnoea, impaired regulation of breathing, inefficient cough and sleep disordered breathing. To understand the mechanisms leading to respiratory disturbances in patients with muscular dystrophy.To understand the impact of respiratory disturbances in patients with muscular dystrophy.To provide a brief description of the main forms of muscular dystrophy with their respiratory implications.
Simulation Assisted Risk Assessment Applied to Launch Vehicle Conceptual Design
NASA Technical Reports Server (NTRS)
Mathias, Donovan L.; Go, Susie; Gee, Ken; Lawrence, Scott
2008-01-01
A simulation-based risk assessment approach is presented and is applied to the analysis of abort during the ascent phase of a space exploration mission. The approach utilizes groupings of launch vehicle failures, referred to as failure bins, which are mapped to corresponding failure environments. Physical models are used to characterize the failure environments in terms of the risk due to blast overpressure, resulting debris field, and the thermal radiation due to a fireball. The resulting risk to the crew is dynamically modeled by combining the likelihood of each failure, the severity of the failure environments as a function of initiator and time of the failure, the robustness of the crew module, and the warning time available due to early detection. The approach is shown to support the launch vehicle design process by characterizing the risk drivers and identifying regions where failure detection would significantly reduce the risk to the crew.
Failure mechanisms of thermal barrier coatings exposed to elevated temperatures
NASA Technical Reports Server (NTRS)
Miller, R. A.; Lowell, C. E.
1982-01-01
The failure of a ZrO2-8%Y2O3/Ni-14% Al-0.1% Zr coating system on Rene 41 in Mach 0.3 burner rig tests was characterized. High flame and metal temperatures were employed in order to accelerate coating failure. Failure by delamination was shown to precede surface cracking or spalling. This type of failure could be duplicated by cooling down the specimen after a single long duration isothermal high temperature cycle in a burner rig or a furnace, but only if the atmosphere was oxidizing. Stresses due to thermal expansion mismatch on cooling coupled with the effects of plastic deformation of the bond coat and oxidation of the irregular bond coat are the probable life limiting factors. Heat up stresses alone could not fail the coating in the burner rig tests. Spalling eventually occurs on heat up but only after the coating has already failed through delamination.
Ueno, K; Fujimoto, S; Fujimoto, T; Nakano, H; Nakajima, T; Yamano, S; Shiiki, H; Hashimoto, T; Imoto, K; Miyagawa, S; Dohi, K
1999-10-01
A 50-year-old female was admitted to a local hospital because of dyspnea, and diagnosed as having left heart failure secondary to mitral regurgitation. After the improvement of congestive heart failure, polyarthralgia, fever, and positive anti-nuclear antibody were pointed out. She was referred to our hospital for the further evaluation. Serological test showed anti-double stranded DNA antibodies, anti-SS-A antibodies, anti-beta 2-GPI antibodies and biological false positive for syphilis. The diagnosis of SLE has been made from the clinical signs and the serology. Therefore mitral valvular lesion of this patient was considered to be one of the symptoms of SLE. We reported a rare case in which left heart failure was a initial clinical manifestation of SLE.
ATS-6 engineering performance report. Volume 2: Orbit and attitude controls
NASA Technical Reports Server (NTRS)
Wales, R. O. (Editor)
1981-01-01
Attitude control is reviewed, encompassing the attitude control subsystem, spacecraft attitude precision pointing and slewing adaptive control experiment, and RF interferometer experiment. The spacecraft propulsion system (SPS) is discussed, including subsystem, SPS design description and validation, orbital operations and performance, in-orbit anomalies and contingency operations, and the cesium bombardment ion engine experiment. Thruster failure due to plugging of the propellant feed passages, a major cause for mission termination, are considered among the critical generic failures on the satellite.
Severe tricuspid regurgitation and isolated right heart failure due to thyrotoxicosis
Bonou, Maria; Lampropoulos, Konstantinos M.; Andriopoulou, Maria; Kotsas, Dimitrios; Lakoumentas, John; Barbetseas, John
2012-01-01
We describe the case of a patient presented with isolated right heart failure with atrial fibrillation and severe tricuspid regurgitation due to hyperthyroidism. Treatment of the thyroid disease resulted in the disappearance of signs of right heart failure and resolution of the valve incompetence and normalization of the heart rhythm. Although thyrotoxicosis may be associated with congestive heart failure, isolated right heart failure with marked tricuspid regurgitation is rarely seen. PMID:23253416
Optimizing the robustness of electrical power systems against cascading failures.
Zhang, Yingrui; Yağan, Osman
2016-06-21
Electrical power systems are one of the most important infrastructures that support our society. However, their vulnerabilities have raised great concern recently due to several large-scale blackouts around the world. In this paper, we investigate the robustness of power systems against cascading failures initiated by a random attack. This is done under a simple yet useful model based on global and equal redistribution of load upon failures. We provide a comprehensive understanding of system robustness under this model by (i) deriving an expression for the final system size as a function of the size of initial attacks; (ii) deriving the critical attack size after which system breaks down completely; (iii) showing that complete system breakdown takes place through a first-order (i.e., discontinuous) transition in terms of the attack size; and (iv) establishing the optimal load-capacity distribution that maximizes robustness. In particular, we show that robustness is maximized when the difference between the capacity and initial load is the same for all lines; i.e., when all lines have the same redundant space regardless of their initial load. This is in contrast with the intuitive and commonly used setting where capacity of a line is a fixed factor of its initial load.
Code of Federal Regulations, 2011 CFR
2011-07-01
... structure (e.g., dike or trench), a drainage control system, or a diversion structure (e.g., standby tank... this inflow (e.g., waste feed cutoff system or by-pass system to a stand-by tank). Note: These systems are intended to be used in the event of a leak or overflow from the tank due to a system failure (e.g...
Code of Federal Regulations, 2014 CFR
2014-07-01
... structure (e.g., dike or trench), a drainage control system, or a diversion structure (e.g., standby tank... this inflow (e.g., waste feed cutoff system or by-pass system to a stand-by tank). Note: These systems are intended to be used in the event of a leak or overflow from the tank due to a system failure (e.g...
Code of Federal Regulations, 2013 CFR
2013-07-01
... structure (e.g., dike or trench), a drainage control system, or a diversion structure (e.g., standby tank... this inflow (e.g., waste feed cutoff system or by-pass system to a stand-by tank). Note: These systems are intended to be used in the event of a leak or overflow from the tank due to a system failure (e.g...
Code of Federal Regulations, 2012 CFR
2012-07-01
... structure (e.g., dike or trench), a drainage control system, or a diversion structure (e.g., standby tank... this inflow (e.g., waste feed cutoff system or by-pass system to a stand-by tank). Note: These systems are intended to be used in the event of a leak or overflow from the tank due to a system failure (e.g...
NASA-LaRc Flight-Critical Digital Systems Technology Workshop
NASA Technical Reports Server (NTRS)
Meissner, C. W., Jr. (Editor); Dunham, J. R. (Editor); Crim, G. (Editor)
1989-01-01
The outcome is documented of a Flight-Critical Digital Systems Technology Workshop held at NASA-Langley December 13 to 15 1988. The purpose of the workshop was to elicit the aerospace industry's view of the issues which must be addressed for the practical realization of flight-critical digital systems. The workshop was divided into three parts: an overview session; three half-day meetings of seven working groups addressing aeronautical and space requirements, system design for validation, failure modes, system modeling, reliable software, and flight test; and a half-day summary of the research issues presented by the working group chairmen. Issues that generated the most consensus across the workshop were: (1) the lack of effective design and validation methods with support tools to enable engineering of highly-integrated, flight-critical digital systems, and (2) the lack of high quality laboratory and field data on system failures especially due to electromagnetic environment (EME).
Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles
NASA Technical Reports Server (NTRS)
Dunn, V. B.
1975-01-01
A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.
Mathiak, Krystyna A; Klasen, Martin; Weber, René; Ackermann, Hermann; Shergill, Sukhwinder S; Mathiak, Klaus
2011-07-12
Violent content in video games evokes many concerns but there is little research concerning its rewarding aspects. It was demonstrated that playing a video game leads to striatal dopamine release. It is unclear, however, which aspects of the game cause this reward system activation and if violent content contributes to it. We combined functional Magnetic Resonance Imaging (fMRI) with individual affect measures to address the neuronal correlates of violence in a video game. Thirteen male German volunteers played a first-person shooter game (Tactical Ops: Assault on Terror) during fMRI measurement. We defined success as eliminating opponents, and failure as being eliminated themselves. Affect was measured directly before and after game play using the Positive and Negative Affect Schedule (PANAS). Failure and success events evoked increased activity in visual cortex but only failure decreased activity in orbitofrontal cortex and caudate nucleus. A negative correlation between negative affect and responses to failure was evident in the right temporal pole (rTP). The deactivation of the caudate nucleus during failure is in accordance with its role in reward-prediction error: it occurred whenever subject missed an expected reward (being eliminated rather than eliminating the opponent). We found no indication that violence events were directly rewarding for the players. We addressed subjective evaluations of affect change due to gameplay to study the reward system. Subjects reporting greater negative affect after playing the game had less rTP activity associated with failure. The rTP may therefore be involved in evaluating the failure events in a social context, to regulate the players' mood.
Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander
2007-01-01
Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).
FEMA and RAM Analysis for the Multi Canister Overpack (MCO) Handling Machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
SWENSON, C.E.
2000-06-01
The Failure Modes and Effects Analysis and the Reliability, Availability, and Maintainability Analysis performed for the Multi-Canister Overpack Handling Machine (MHM) has shown that the current design provides for a safe system, but the reliability of the system (primarily due to the complexity of the interlocks and permissive controls) is relatively low. No specific failure modes were identified where significant consequences to the public occurred, or where significant impact to nearby workers should be expected. The overall reliability calculation for the MHM shows a 98.1 percent probability of operating for eight hours without failure, and an availability of the MHMmore » of 90 percent. The majority of the reliability issues are found in the interlocks and controls. The availability of appropriate spare parts and maintenance personnel, coupled with well written operating procedures, will play a more important role in successful mission completion for the MHM than other less complicated systems.« less
Reliability of Fault Tolerant Control Systems. Part 2
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2000-01-01
This paper reports Part II of a two part effort that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability properties peculiar to fault-tolerant control systems are emphasized, such as the presence of analytic redundancy in high proportion, the dependence of failures on control performance, and high risks associated with decisions in redundancy management due to multiple sources of uncertainties and sometimes large processing requirements. As a consequence, coverage of failures through redundancy management can be severely limited. The paper proposes to formulate the fault tolerant control problem as an optimization problem that maximizes coverage of failures through redundancy management. Coverage modeling is attempted in a way that captures its dependence on the control performance and on the diagnostic resolution. Under the proposed redundancy management policy, it is shown that an enhanced overall system reliability can be achieved with a control law of a superior robustness, with an estimator of a higher resolution, and with a control performance requirement of a lesser stringency.
Methods for Decontamination of a Bipropellant Propulsion System
NASA Technical Reports Server (NTRS)
McClure, Mark B.; Greene, Benjamin
2012-01-01
Most propulsion systems are designed to be filled and flown, draining can be done but decontamination may be difficult. Transport of these systems may be difficult as well because flight weight vessels are not designed around DOT or UN shipping requirements. Repairs, failure analysis work or post firing inspections may be difficult or impossible to perform due to the hazards of residual propellants being present.
14 CFR 152.109 - Project eligibility: Airport planning.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; and (5) In the case of a proposed project for airport master planning in a large or medium air traffic hub, in the opinion of the Administrator— (i) There is an appropriate system plan identifying the need for the airport; (ii) The absence of a system plan is due to the failure of the responsible planning...
LMI-based adaptive reliable H∞ static output feedback control against switched actuator failures
NASA Astrophysics Data System (ADS)
An, Liwei; Zhai, Ding; Dong, Jiuxiang; Zhang, Qingling
2017-08-01
This paper investigates the H∞ static output feedback (SOF) control problem for switched linear system under arbitrary switching, where the actuator failure models are considered to depend on switching signal. An active reliable control scheme is developed by combination of linear matrix inequality (LMI) method and adaptive mechanism. First, by exploiting variable substitution and Finsler's lemma, new LMI conditions are given for designing the SOF controller. Compared to the existing results, the proposed design conditions are more relaxed and can be applied to a wider class of no-fault linear systems. Then a novel adaptive mechanism is established, where the inverses of switched failure scaling factors are estimated online to accommodate the effects of actuator failure on systems. Two main difficulties arise: first is how to design the switched adaptive laws to prevent the missing of estimating information due to switching; second is how to construct a common Lyapunov function based on a switched estimate error term. It is shown that the new method can give less conservative results than that for the traditional control design with fixed gain matrices. Finally, simulation results on the HiMAT aircraft are given to show the effectiveness of the proposed approaches.
NASA Astrophysics Data System (ADS)
Setiawan, A.; Wangsaputra, R.; Martawirya, Y. Y.; Halim, A. H.
2016-02-01
This paper deals with Flexible Manufacturing System (FMS) production rescheduling due to unavailability of cutting tools caused either of cutting tool failure or life time limit. The FMS consists of parallel identical machines integrated with an automatic material handling system and it runs fully automatically. Each machine has a same cutting tool configuration that consists of different geometrical cutting tool types on each tool magazine. The job usually takes two stages. Each stage has sequential operations allocated to machines considering the cutting tool life. In the real situation, the cutting tool can fail before the cutting tool life is reached. The objective in this paper is to develop a dynamic scheduling algorithm when a cutting tool is broken during unmanned and a rescheduling needed. The algorithm consists of four steps. The first step is generating initial schedule, the second step is determination the cutting tool failure time, the third step is determination of system status at cutting tool failure time and the fourth step is the rescheduling for unfinished jobs. The approaches to solve the problem are complete-reactive scheduling and robust-proactive scheduling. The new schedules result differences starting time and completion time of each operations from the initial schedule.
Data Applicability of Heritage and New Hardware For Launch Vehicle Reliability Models
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Novack, Steven
2015-01-01
Bayesian reliability requires the development of a prior distribution to represent degree of belief about the value of a parameter (such as a component's failure rate) before system specific data become available from testing or operations. Generic failure data are often provided in reliability databases as point estimates (mean or median). A component's failure rate is considered a random variable where all possible values are represented by a probability distribution. The applicability of the generic data source is a significant source of uncertainty that affects the spread of the distribution. This presentation discusses heuristic guidelines for quantifying uncertainty due to generic data applicability when developing prior distributions mainly from reliability predictions.
The determination of measures of software reliability
NASA Technical Reports Server (NTRS)
Maxwell, F. D.; Corn, B. C.
1978-01-01
Measurement of software reliability was carried out during the development of data base software for a multi-sensor tracking system. The failure ratio and failure rate were found to be consistent measures. Trend lines could be established from these measurements that provide good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.
Current role of neprilysin inhibitors in hypertension and heart failure.
von Lueder, Thomas G; Atar, Dan; Krum, Henry
2014-10-01
Cardiovascular diseases (CVD) continue to represent the major cause of death, morbidity and healthcare expenditure worldwide. Current medical therapy fails to effectively halt disease progression and to reduce adverse clinical outcomes, reflecting incomplete understanding of pathomechanisms as well as the need to expand current pharmacotherapeutic strategies. Hypertension and heart failure, the most important CVD entities, are associated with imbalance in neurohormonal systems activity such as the renin-angiotensin-aldosterone system (RAAS), the sympathetic nervous system and the endothelin system. Blockade of the RAAS constitutes the most successful pharmacotherapeutic concept in hypertension and heart failure to date. The RAAS-opposing natriuretic peptide system constitutes the body's own BP-lowering system, and mediates a multitude of beneficial actions within cardiovascular tissues. The metallopeptidase neprilysin (NEP) hydrolyzes natriuretic peptides. Conceptually, NEP inhibition would increase salutary natriuretic peptide actions in CVD. However, stand-alone NEP inhibitors (NEPi) lacked efficacy beyond standard pharmacotherapy. Combined blockers of NEP and the endothelin system demonstrated efficacy in preclinical studies but have not been evaluated in clinical trials. A decade ago, omapatrilat and other dual-acting NEPi-ACEi (vasopeptidase-inhibitors) were promising agents for hypertension and heart failure. Despite greater efficacy, development of vasopeptidase-inhibitors was halted due to significant off-target effects in some cohorts, most notably increased frequency of angioedema in hypertensive subjects. Novel angiotensin-receptor-neprilysin-inhibitors (ARNi) seek to fully exploit clinical efficacy of combined RAAS-blockade and NEPi-mediated natriuretic peptide augmentation, and hopefully do so with improved clinical safety. We herein review current knowledge of NEPi as stand-alone and combined pharmacotherapeutic agents in hypertension and heart failure. Copyright © 2014. Published by Elsevier Inc.
Popova, J A; Yadrihinskaya, V N; Krylova, M I; Sleptsovа, S S; Borisovа, N V
frequent complications of hemodialysis treatments are coagulation disorders. This is due to activation of the coagulation of blood flow in the interaction with a dialysis membrane material vascular prostheses and extracorporeal circuit trunks. In addition, in hemodialysis patients receiving heparin for years, there is depletion of stocks in endothelial cells in tissue factor inhibitor, inhibits the activity of an external blood clotting mechanism. the aim of our study was to evaluate the hemostatic system parameters in patients with end-stage renal failure, depending on the cause of renal failure. to evaluate the hemostatic system parameters in patients with end-stage renal failure, depending on the cause of renal failure and hemodialysis treatment duration conducted a study that included 100 patients observed in the department of chronic hemodialysis and nephrology hospital №1 Republican National Medical Center in the period of 2013-2016. in patients with end-stage renal failure in the outcome of chronic glomerulonephritis, a great expression of activation of blood coagulation confirm increased the mean concentration of fibrinogen, whereas in the group, which included patients with end-stage renal failure in the outcome of other diseases, such is not different from the norm, and a higher rate of hyperfibrinogenemia, identified in 2/3 patients in this group. it was revealed that the state of homeostasis in patients with end-stage renal failure in increasingly characterizes the level of fibrinogen and the activation of the hemostatic markers: soluble fibrin monomer complexes, D-dimers.
Effects of arcing due to spacecraft charging on spacecraft survival
NASA Technical Reports Server (NTRS)
Rosen, A.; Sanders, N. L.; Ellen, J. M., Jr.; Inouye, G. T.
1978-01-01
A quantitative assessment of the hazard associated with spacecraft charging and arcing on spacecraft systems is presented. A literature survey on arc discharge thresholds and characteristics was done and gaps in the data and requirements for additional experiments were identified. Calculations of coupling of arc discharges into typical spacecraft systems were made and the susceptibility of typical spacecraft to disruption by arc discharges was investigated. Design guidelines and recommended practices to reduce or eliminate the threat of malfunction and failures due to spacecraft charging/arcing were summarized.
Effect of Joule heating and current crowding on electromigration in mobile technology
NASA Astrophysics Data System (ADS)
Tu, K. N.; Liu, Yingxia; Li, Menglu
2017-03-01
In the present era of big data and internet of things, the use of microelectronic products in all aspects of our life is manifested by the ubiquitous presence of mobile devices as i-phones and wearable i-products. These devices are facing the need for higher power and greater functionality applications such as in i-health, yet they are limited by physical size. At the moment, software (Apps) is much ahead of hardware in mobile technology. To advance hardware, the end of Moore's law in two-dimensional integrated circuits can be extended by three-dimensional integrated circuits (3D ICs). The concept of 3D ICs has been with us for more than ten years. The challenge in 3D IC technology is dense packing by using both vertical and horizontal interconnections. Mass production of 3D IC devices is behind schedule due to cost because of low yield and uncertain reliability. Joule heating is serious in a dense structure because of heat generation and dissipation. A change of reliability paradigm has advanced from failure at a specific circuit component to failure at a system level weak-link. Currently, the electronic industry is introducing 3D IC devices in mainframe computers, where cost is not an issue, for the purpose of collecting field data of failure, especially the effect of Joule heating and current crowding on electromigration. This review will concentrate on the positive feedback between Joule heating and electromigration, resulting in an accelerated system level weak-link failure. A new driving force of electromigration, the electric potential gradient force due to current crowding, will be reviewed critically. The induced failure tends to occur in the low current density region.
NASA Astrophysics Data System (ADS)
Moscardelli, L.; Wood, L. J.
2006-12-01
Several late Pleistocene-age seafloor destabilization events have been identified in the continental margin of eastern offshore Trinidad, of sufficient scale to produce tsunamigenic forces. This area, situated along the obliquely-converging-boundary of the Caribbean/South American plates and proximal to the Orinoco Delta, is characterized by catastrophic shelf-margin processes, intrusive-extrusive mobile shales, and active tectonism. A mega-merged, 10,000km2, 3D seismic survey reveals several mass transport complexes that range in area from 11.3km2 to 2017km2. Historical records indicate that this region has experienced submarine landslide- generated tsunamigenic events, including tsunamis that affected Venezuela during the 1700's-1900's. This work concentrates on defining those ancient deep marine mass transport complexes whose occurrence could potentially triggered tsunamis. Three types of failures are identified; 1) source-attached failures that are fed by shelf edge deltas whose sediment input is controlled by sea-level fluctuations and sedimentation rates, 2) source-detached systems, which occur when upper slope sediments catastrophically fail due to gas hydrate disruptions and/or earthquakes, and 3) locally sourced failures, formed when local instabilities in the sea floor trigger relatively smaller collapses. Such classification of the relationship between slope mass failures and the sourcing regions enables a better understanding of the nature of initiation, length of development history and petrography of such mass transport deposits. Source-detached systems, generated due to sudden sediment remobilizations, are more likely to disrupt the overlying water column causing a rise in tsunamigenic risk. Unlike 2D seismic, 3D seismic enables scientists to calculate more accurate deposit volumes, improve deposit imaging and thus increase the accuracy of physical and computer simulations of mass failure processes.
Contrasting actions of pressor agents in severe autonomic failure
NASA Technical Reports Server (NTRS)
Jordan, J.; Shannon, J. R.; Biaggioni, I.; Norman, R.; Black, B. K.; Robertson, D.
1998-01-01
BACKGROUND: Orthostatic hypotension is the most disabling symptom of autonomic failure. The choice of a pressor agent is largely empiric, and it would be of great value to define predictors of a response. PATIENTS AND METHODS: In 35 patients with severe orthostatic hypotension due to multiple system atrophy or pure autonomic failure, we determined the effect on seated systolic blood pressure (SBP) of placebo, phenylpropanolamine (12.5 mg and 25 mg), yohimbine (5.4 mg), indomethacin (50 mg), ibuprofen (600 mg), caffeine (250 mg), and methylphenidate (5 mg). In a subgroup of patients, we compared the pressor effect of midodrine (5 mg) with the effect of phenylpropanolamine (12.5 mg). RESULTS: There were no significant differences in the pressor responses between patients with multiple system atrophy or pure autonomic failure. When compared with placebo, the pressor response was significant for phenylpropanolamine, yohimbine, and indomethacin. In a subgroup of patients, we confirmed that this pressor effect of phenylpropanolamine, yohimbine, and indomethacin corresponded to a significant increase in standing SBP. The pressor responses to ibuprofen, caffeine, and methylphenidate were not significantly different from placebo. Phenylpropanolamine and midodrine elicited similar pressor responses. There were no significant associations between drug response and autonomic function testing, postprandial hypotension, or plasma catecholamine levels. CONCLUSIONS: We conclude that significant increases in systolic blood pressure can be obtained in patients with orthostatic hypotension due to primary autonomic failure with phenylpropanolamine in low doses or yohimbine or indomethacin in moderate doses. The response to a pressor agent cannot be predicted by autonomic function testing or plasma catecholamines. Therefore, empiric testing with a sequence of medications, based on the risk of side effects in the individual patient and the probability of a response, is a useful approach.
Correa-Rotter, R; Gamba, G; Ochoa, C; Onuma, L; Reyes, E; Tamayo, J A; Peña, J C
1990-01-01
The purpose of this retrospective study was to study the incidence of idiopathic and secondary forms of membranous nephropathy in our institution, its clinical course and progression to chronic renal failure, and the risk factors associated with it. Two hundred fourteen (16%) of the 1,287 renal biopsies obtained between 1962 and 1988 were primary glomerular diseases and 28 of this 214 (13%) were idiopathic membranous nephropathy. On the other hand 59 of 1,287 biopsies were membranous nephropathy of whom 28 were idiopathic, 27 secondary to systemic lupus erythematosus, 2 due to drugs, one associated with rheumatoid arthritis, and one more with breast cancer. The clinical picture was: nephrotic syndrome in 84%, hypertension in 15%, non-nephrotic proteinuria in 14%, chronic renal failure in 8.4%, and renal vein thrombosis in 6.3%. In the idiopathic group 75% of the patients were male while in the lupus group 85% were female. For the analysis of progression to chronic renal failure we excluded 5 patients with renal failure when the biopsy was taken, 2 because the nephropathy was due to drugs, one associated with breast cancer, and nine were within the first year of follow-up. Thus, for this analysis the group consisted of 22 patients with idiopathic form and 20 with systemic lupus erythematosus. The idiopathic and lupus groups were similar except for a lower serum albumin in the former. The progression to renal failure was seen in 9 patients: six in the idiopathic group and the other 3 in the lupus group; this difference was not significant.(ABSTRACT TRUNCATED AT 250 WORDS)
14 CFR 25.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the engine compressor from the turbine or from loss of the turbine blades are considered to be... § 25.367 Unsymmetrical loads due to engine failure. (a) The airplane must be designed for the unsymmetrical loads resulting from the failure of the critical engine. Turbopropeller airplanes must be designed...
14 CFR 25.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the engine compressor from the turbine or from loss of the turbine blades are considered to be... § 25.367 Unsymmetrical loads due to engine failure. (a) The airplane must be designed for the unsymmetrical loads resulting from the failure of the critical engine. Turbopropeller airplanes must be designed...
14 CFR 25.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the engine compressor from the turbine or from loss of the turbine blades are considered to be... § 25.367 Unsymmetrical loads due to engine failure. (a) The airplane must be designed for the unsymmetrical loads resulting from the failure of the critical engine. Turbopropeller airplanes must be designed...
NASA Technical Reports Server (NTRS)
Hatfield, Glen S.; Hark, Frank; Stott, James
2016-01-01
Launch vehicle reliability analysis is largely dependent upon using predicted failure rates from data sources such as MIL-HDBK-217F. Reliability prediction methodologies based on component data do not take into account system integration risks such as those attributable to manufacturing and assembly. These sources often dominate component level risk. While consequence of failure is often understood, using predicted values in a risk model to estimate the probability of occurrence may underestimate the actual risk. Managers and decision makers use the probability of occurrence to influence the determination whether to accept the risk or require a design modification. The actual risk threshold for acceptance may not be fully understood due to the absence of system level test data or operational data. This paper will establish a method and approach to identify the pitfalls and precautions of accepting risk based solely upon predicted failure data. This approach will provide a set of guidelines that may be useful to arrive at a more realistic quantification of risk prior to acceptance by a program.
Numerical simulation of CTE mismatch and thermal-structural stresses in the design of interconnects
NASA Astrophysics Data System (ADS)
Peter, Geoffrey John M.
With the ever-increasing chip complexity, interconnects have to be designed to meet the new challenges. Advances in optical lithography have made chip feature sizes available today at 70 nm dimensions. With advances in Extreme Ultraviolet Lithography, X-ray Lithography, and Ion Projection Lithography it is expected that the line width will further decrease to 20 nm or less. With the decrease in feature size, the number of active devices on the chip increases. With higher levels of circuit integration, the challenge is to dissipate the increased heat flux from the chip surface area. Thermal management considerations include coefficient of thermal expansion (CTE) matching to prevent failure between the chip and the board. This in turn calls for improved system performance and reliability of the electronic structural systems. Experience has shown that in most electronic systems, failures are mostly due to CTE mismatch between the chip, board, and the solder joint (solder interconnect). The resulting high thermal-structural stress and strain due to CTE mismatch produces cracks in the solder joints with eventual failure of the electronic component. In order to reduce the thermal stress between the chip, board, and the solder joint, this dissertation examines the effect of inserting wire bundle (wire interconnect) between the chip and the board. The flexibility of the wires or fibers would reduce the stress at the rigid joints. Numerical simulations of two, and three-dimensional models of the solder and wire interconnects are examined. The numerical simulation is linear in nature and is based on linear isotropic material properties. The effect of different wire material properties is examined. The effect of varying the wire diameter is studied by changing the wire diameter. A major cause of electronic equipment failure is due to fatigue failure caused by thermal cycling, and vibrations. A two-dimensional modal and harmonic analysis was simulated for the wire interconnect and the solder interconnect. The numerical model simulated using ANSYS program was validated with the numerical/experimental results of other published researchers. In addition the results were cross-checked by IDEAS program. A prototype non-working wire interconnect is proposed to emphasize practical application. The numerical analysis, in this dissertation is based on a U.S. Patent granted to G. Peter(42).
Oral theophylline in chronic heart failure
Al-Damluji, S.; Johnston, A.; Spurrell, R. A. J.; Nathan, A. W.; Banim, S. O.; Camm, A. J.
1982-01-01
Theophylline choline 600 mg was given as a single oral dose to nine patients in chronic left ventricular failure due to myocardial dysfunction. Cardiac output, left ventricular filling pressure (LVFP) and right atrial pressure (RAP) were measured with a pulmonary artery thermodilution catheter for the following 3 hr. Continuous recordings of cardiac rhythm were made throughout the study. Mean cardiac index increased from 1·75 (±0·14 s.e. mean) to 2·04 (±0·11) 1/min/m2 (P<0·02), mean LVFP fell from 27 (±2·4) to 22 (±1·5) mmHg (P<0·01), mean RAP fell from 5 (±1·3) to 3 (±2·0) mmHg (P<0·05) and mean systemic arterial pressure rose from 80 (±3) to 86 (±3·5) mmHg (P<0·05). There were no significant changes in heart rate or systemic vascular resistance; thus the increase in cardiac output was probably due to a positive inotropic effect. Side effects were seen in two patients, both of whom proved to have toxic plasma theophylline concentrations. This study demonstrated a beneficial acute haemodynamic effect of oral theophylline in chronic cardiac failure. PMID:7111101
NASA Technical Reports Server (NTRS)
Shin, Jong-Yeob; Belcastro, Christine; Khong, thuan
2006-01-01
Formal robustness analysis of aircraft control upset prevention and recovery systems could play an important role in their validation and ultimate certification. Such systems developed for failure detection, identification, and reconfiguration, as well as upset recovery, need to be evaluated over broad regions of the flight envelope or under extreme flight conditions, and should include various sources of uncertainty. To apply formal robustness analysis, formulation of linear fractional transformation (LFT) models of complex parameter-dependent systems is required, which represent system uncertainty due to parameter uncertainty and actuator faults. This paper describes a detailed LFT model formulation procedure from the nonlinear model of a transport aircraft by using a preliminary LFT modeling software tool developed at the NASA Langley Research Center, which utilizes a matrix-based computational approach. The closed-loop system is evaluated over the entire flight envelope based on the generated LFT model which can cover nonlinear dynamics. The robustness analysis results of the closed-loop fault tolerant control system of a transport aircraft are presented. A reliable flight envelope (safe flight regime) is also calculated from the robust performance analysis results, over which the closed-loop system can achieve the desired performance of command tracking and failure detection.
Friedl, Alexander; Mühlstädt, Sandra; Rom, Maximilian; Kivaranovic, Danijel; Mohammed, Nasreldin; Fornara, Paolo; Brössner, Clemens
2016-04-01
To identify risk factors for treatment failure of men with the adjustable transobturator male system (ATOMS) for treating stress urinary incontinence (SUI). Sixty-two patients with SUI after prostate surgery were provided with an ATOMS. The self-defined criteria for treatment failure (implant removal [A], no improvement or ≥3 pads/24 hours [B], and no improvement or ≥150 mL urine loss/24 hours [C]) were compared to anamnestic, clinical, and time-specific parameters: age, Charlson comorbidity index (CCI), urine culture (UC), previous ineffective implants, body mass index, radiotherapy, renal function (serum creatinine), smoker status, urethral strictures, SUI severity, surgery time, time to and season at implantation, and port system application. After a median follow-up of 17.7 months, 9 ATOMS (15%) were removed due to infection (8) or dysfunction (1); 23% and 16% had treatment failure of criteria B and C. Dry rate/overall success rate was 61%/87%. Age alone was no risk factor but the CCI and a positive UC were univariate significant predictors of the criteria A, B, and C. Besides, previous devices and renal failure were significantly associated with implant removal (A) and SUI severity with criterion C. In multivariate analysis, previous devices (P = .0163), positive UC (P = .0190), and SUI severity (P = .0123) were the strongest predictors of A, B, and C, respectively. A poor CCI, preoperative positive UC, severe SUI, and previous implants lead to more treatment failure and removal. Age, body mass index, radiotherapy, urethral strictures, current smoking, time-specific parameters, seasonality, and port system application did not influence the outcome. Copyright © 2016 Elsevier Inc. All rights reserved.
[Progressive damage monitoring of corrugated composite skins by the FBG spectral characteristics].
Zhang, Yong; Wang, Bang-Feng; Lu, Ji-Yun; Gu, Li-Li; Su, Yong-Gang
2014-03-01
In the present paper, a method of monitoring progressive damage of composite structures by non-uniform fiber Bragg grating (FBG) reflection spectrum is proposed. Due to the finite element analysis of corrugated composite skins specimens, the failure process under tensile load and corresponding critical failure loads of corrugated composite skin was predicated. Then, the non-uniform reflection spectrum of FBG sensor could be reconstructed and the corresponding relationship between layer failure order sequence of corrugated composite skin and FBG sensor reflection spectrums was acquired. A monitoring system based on FBG non-uniform reflection spectrum, which can be used to monitor progressive damage of corrugated composite skins, was built. The corrugated composite skins were stretched under this FBG non-uniform reflection spectrum monitoring system. The results indicate that real-time spectrums acquired by FBG non-uniform reflection spectrum monitoring system show the same trend with the reconstruction reflection spectrums. The maximum error between the corresponding failure and the predictive value is 8.6%, which proves the feasibility of using FBG sensor to monitor progressive damage of corrugated composite skin. In this method, the real-time changes in the FBG non-uniform reflection spectrum within the scope of failure were acquired through the way of monitoring and predicating, and at the same time, the progressive damage extent and layer failure sequence of corru- gated composite skin was estimated, and without destroying the structure of the specimen, the method is easy and simple to operate. The measurement and transmission section of the system are completely composed of optical fiber, which provides new ideas and experimental reference for the field of dynamic monitoring of smart skin.
Kidney failure; Renal failure; Renal failure - acute; ARF; Kidney injury - acute ... There are many possible causes of kidney damage. They include: ... cholesterol (cholesterol emboli) Decreased blood flow due to very ...
The equal load-sharing model of cascade failures in power grids
NASA Astrophysics Data System (ADS)
Scala, Antonio; De Sanctis Lucentini, Pier Giorgio
2016-11-01
Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing power demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into ;super-grids;.
Abruptness of Cascade Failures in Power Grids
NASA Astrophysics Data System (ADS)
Pahwa, Sakshi; Scoglio, Caterina; Scala, Antonio
2014-01-01
Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results on real, realistic and synthetic networks indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into ``super-grids''.
Abruptness of cascade failures in power grids.
Pahwa, Sakshi; Scoglio, Caterina; Scala, Antonio
2014-01-15
Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results on real, realistic and synthetic networks indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into "super-grids".
Abruptness of Cascade Failures in Power Grids
Pahwa, Sakshi; Scoglio, Caterina; Scala, Antonio
2014-01-01
Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results on real, realistic and synthetic networks indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into “super-grids”. PMID:24424239
Keeping Up with Healthcare Trends: IcHeart as a Medication Management Application
NASA Astrophysics Data System (ADS)
Kasinathan, Vinothini; Mustapha, Aida; Azah Samsudin, Noor
2016-11-01
According to the US governments, more than 125,000 people die each year due to failure to manage their medications, leading to approximately USD100 billion in preventable costs to healthcare systems. The core failure in medication management is attributed by patients failing to adhere their medication regimens, whether by accident, negligence, or intentional. Recognizing the importants of vigilant monitoring in medication management, this paper is set to review the latest android-based healthcare trends and propose a new mobile medication reminder application called IcHeart.
Transportable Life Support for Treatment of Acute Lung Failure Due to Smoke Inhalation and Burns
2014-04-01
and all vital sign and medical monitor data collected in the animal ICU . The system is in use in the animal ICU daily and we will report on its... Influenza A(H1N1) Acute Respiratory Distress Syndrome. JAMA. Nov 4 2009;302(17):1888-1895. 9. Napolitano LM, Park PK, Raghavendran K, Bartlett RH...Nonventilatory strategies for patients with life-threatening 2009 H1N1 influenza and severe respiratory failure. Crit Care Med. Apr 2010;38(4 Suppl
Impact of lightning strikes on hospital functions.
Mortelmans, Luc J M; Van Springel, Gert L J; Van Boxstael, Sam; Herrijgers, Jan; Hoflacks, Stefaan
2009-01-01
Two regional hospitals were struck by lightning during a one-month period. The first hospital, which had 236 beds, suffered a direct strike to the building. This resulted in a direct spread of the power peak and temporary failure of the standard power supply. The principle problems, after restoring standard power supply, were with the fire alarm system and peripheral network connections in the digital radiology systems. No direct impact on the hardware could be found. Restarting the servers resolved all problems. The second hospital, which had 436 beds, had a lightning strike on the premises and mainly experienced problems due to induction. All affected installations had a cable connection from outside in one way or another. The power supplies never were endangered. The main problem was the failure of different communication systems (telephone, radio, intercom, fire alarm system). Also, the electronic entrance control went out. During the days after the lightening strike, multiple software problems became apparent, as well as failures of the network connections controlling the technical support systems. There are very few ways to prepare for induction problems. The use of fiber-optic networks can limit damage. To the knowledge of the authors, these are the first cases of lightning striking hospitals in medical literature.
Matrix Dominated Failure of Fiber-Reinforced Composite Laminates Under Static and Dynamic Loading
NASA Astrophysics Data System (ADS)
Schaefer, Joseph Daniel
Hierarchical material systems provide the unique opportunity to connect material knowledge to solving specific design challenges. Representing the quickest growing class of hierarchical materials in use, fiber-reinforced polymer composites (FRPCs) offer superior strength and stiffness-to-weight ratios, damage tolerance, and decreasing production costs compared to metals and alloys. However, the implementation of FRPCs has historically been fraught with inadequate knowledge of the material failure behavior due to incomplete verification of recent computational constitutive models and improper (or non-existent) experimental validation, which has severely slowed creation and development. Noted by the recent Materials Genome Initiative and the Worldwide Failure Exercise, current state of the art qualification programs endure a 20 year gap between material conceptualization and implementation due to the lack of effective partnership between computational coding (simulation) and experimental characterization. Qualification processes are primarily experiment driven; the anisotropic nature of composites predisposes matrix-dominant properties to be sensitive to strain rate, which necessitates extensive testing. To decrease the qualification time, a framework that practically combines theoretical prediction of material failure with limited experimental validation is required. In this work, the Northwestern Failure Theory (NU Theory) for composite lamina is presented as the theoretical basis from which the failure of unidirectional and multidirectional composite laminates is investigated. From an initial experimental characterization of basic lamina properties, the NU Theory is employed to predict the matrix-dependent failure of composites under any state of biaxial stress from quasi-static to 1000 s-1 strain rates. It was found that the number of experiments required to characterize the strain-rate-dependent failure of a new composite material was reduced by an order of magnitude, and the resulting strain-rate-dependence was applicable for a large class of materials. The presented framework provides engineers with the capability to quickly identify fiber and matrix combinations for a given application and determine the failure behavior over the range of practical loadings cases. The failure-mode-based NU Theory may be especially useful when partnered with computational approaches (which often employ micromechanics to determine constituent and constitutive response) to provide accurate validation of the matrix-dominated failure modes experienced by laminates during progressive failure.
2011-01-01
Background Violent content in video games evokes many concerns but there is little research concerning its rewarding aspects. It was demonstrated that playing a video game leads to striatal dopamine release. It is unclear, however, which aspects of the game cause this reward system activation and if violent content contributes to it. We combined functional Magnetic Resonance Imaging (fMRI) with individual affect measures to address the neuronal correlates of violence in a video game. Results Thirteen male German volunteers played a first-person shooter game (Tactical Ops: Assault on Terror) during fMRI measurement. We defined success as eliminating opponents, and failure as being eliminated themselves. Affect was measured directly before and after game play using the Positive and Negative Affect Schedule (PANAS). Failure and success events evoked increased activity in visual cortex but only failure decreased activity in orbitofrontal cortex and caudate nucleus. A negative correlation between negative affect and responses to failure was evident in the right temporal pole (rTP). Conclusions The deactivation of the caudate nucleus during failure is in accordance with its role in reward-prediction error: it occurred whenever subject missed an expected reward (being eliminated rather than eliminating the opponent). We found no indication that violence events were directly rewarding for the players. We addressed subjective evaluations of affect change due to gameplay to study the reward system. Subjects reporting greater negative affect after playing the game had less rTP activity associated with failure. The rTP may therefore be involved in evaluating the failure events in a social context, to regulate the players' mood. PMID:21749711
Developing Reliable Life Support for Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.
A risk-based approach to sanitary sewer pipe asset management.
Baah, Kelly; Dubey, Brajesh; Harvey, Richard; McBean, Edward
2015-02-01
Wastewater collection systems are an important component of proper management of wastewater to prevent environmental and human health implications from mismanagement of anthropogenic waste. Due to aging and inadequate asset management practices, the wastewater collection assets of many cities around the globe are in a state of rapid decline and in need of urgent attention. Risk management is a tool which can help prioritize resources to better manage and rehabilitate wastewater collection systems. In this study, a risk matrix and a weighted sum multi-criteria decision-matrix are used to assess the consequence and risk of sewer pipe failure for a mid-sized city, using ArcGIS. The methodology shows that six percent of the uninspected sewer pipe assets of the case study have a high consequence of failure while four percent of the assets have a high risk of failure and hence provide priorities for inspection. A map incorporating risk of sewer pipe failure and consequence is developed to facilitate future planning, rehabilitation and maintenance programs. The consequence of failure assessment also includes a novel failure impact factor which captures the effect of structurally defective stormwater pipes on the failure assessment. The methodology recommended in this study can serve as a basis for future planning and decision making and has the potential to be universally applied by municipal sewer pipe asset managers globally to effectively manage the sanitary sewer pipe infrastructure within their jurisdiction. Copyright © 2014 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 45 Public Welfare 4 2011-10-01 2011-10-01 false Withholding Federal funds due to failure to... Section 1355.36 Public Welfare Regulations Relating to Public Welfare (Continued) OFFICE OF HUMAN... FAMILIES, FOSTER CARE MAINTENANCE PAYMENTS, ADOPTION ASSISTANCE, AND CHILD AND FAMILY SERVICES GENERAL...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 45 Public Welfare 4 2012-10-01 2012-10-01 false Withholding Federal funds due to failure to... Section 1355.36 Public Welfare Regulations Relating to Public Welfare (Continued) OFFICE OF HUMAN... FAMILIES, FOSTER CARE MAINTENANCE PAYMENTS, ADOPTION ASSISTANCE, AND CHILD AND FAMILY SERVICES GENERAL...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 45 Public Welfare 4 2014-10-01 2014-10-01 false Withholding Federal funds due to failure to... Section 1355.36 Public Welfare Regulations Relating to Public Welfare (Continued) OFFICE OF HUMAN... FAMILIES, FOSTER CARE MAINTENANCE PAYMENTS, ADOPTION ASSISTANCE, AND CHILD AND FAMILY SERVICES GENERAL...
High-throughput sequencing: a failure mode analysis.
Yang, George S; Stott, Jeffery M; Smailus, Duane; Barber, Sarah A; Balasundaram, Miruna; Marra, Marco A; Holt, Robert A
2005-01-04
Basic manufacturing principles are becoming increasingly important in high-throughput sequencing facilities where there is a constant drive to increase quality, increase efficiency, and decrease operating costs. While high-throughput centres report failure rates typically on the order of 10%, the causes of sporadic sequencing failures are seldom analyzed in detail and have not, in the past, been formally reported. Here we report the results of a failure mode analysis of our production sequencing facility based on detailed evaluation of 9,216 ESTs generated from two cDNA libraries. Two categories of failures are described; process-related failures (failures due to equipment or sample handling) and template-related failures (failures that are revealed by close inspection of electropherograms and are likely due to properties of the template DNA sequence itself). Preventative action based on a detailed understanding of failure modes is likely to improve the performance of other production sequencing pipelines.
Thermal Effect on Fracture Integrity in Enhanced Geothermal Systems
NASA Astrophysics Data System (ADS)
Zeng, C.; Deng, W.; Wu, C.; Insall, M.
2017-12-01
In enhanced geothermal systems (EGS), cold fluid is injected to be heated up for electricity generation purpose, and pre-existing fractures are the major conduits for fluid transport. Due to the relative cold fluid injection, the rock-fluid temperature difference will induce thermal stress along the fracture wall. Such large thermal stress could cause the failure of self-propping asperities and therefore change the fracture integrity, which could affect the heat recovery efficiency and fluid recycling. To study the thermal effect on fracture integrity, two mechanisms pertinent to thermal stress are proposed to cause asperity contact failure: (1) the crushing between two pairing asperities leads to the failure at contact area, and (2) the thermal spalling expedites this process. Finite element modeling is utilized to investigate both failure mechanisms by idealizing the asperities as hemispheres. In the numerical analysis, we have implemented meso-scale damage model to investigate coupled failure mechanism induced by thermomechanical stress field and original overburden pressure at the vicinity of contact point. Our results have shown that both the overburden pressure and a critical temperature determine the threshold of asperity failure. Since the overburden pressure implies the depth of fractures in EGS and the critical temperature implies the distance of fractures to the injection well, our ultimate goal is to locate a region of EGS where the fracture integrity is vulnerable to such thermal effect and estimate the influences.
Recent advances in computational structural reliability analysis methods
NASA Astrophysics Data System (ADS)
Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.
1993-10-01
The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.
Recent advances in computational structural reliability analysis methods
NASA Technical Reports Server (NTRS)
Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.
1993-01-01
The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.
Comparison of the compressive strengths for stitched and toughened composite systems
NASA Technical Reports Server (NTRS)
Reeder, James R.
1994-01-01
The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30 percent reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened materials showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30 percent below their ambient strengths for shorter, nonbuckling specimen, while the strength of the toughened matrix material only fell 20 percent. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance, however, seems to be a misleading indication of the cause of failure.
Assessing the Climate Resilience of Transport Infrastructure Investments in Tanzania
NASA Astrophysics Data System (ADS)
Hall, J. W.; Pant, R.; Koks, E.; Thacker, S.; Russell, T.
2017-12-01
Whilst there is an urgent need for infrastructure investment in developing countries, there is a risk that poorly planned and built infrastructure will introduce new vulnerabilities. As climate change increases the magnitudes and frequency of natural hazard events, incidence of disruptive infrastructure failures are likely to become more frequent. Therefore, it is important that infrastructure planning and investment is underpinned by climate risk assessment that can inform adaptation planning. Tanzania's rapid economic growth is placing considerable strain on the country's transportation infrastructure (roads, railways, shipping and aviation); especially at the port of Dar es Salaam and its linking transport corridors. A growing number of natural hazard events, in particular flooding, are impacting the reliability of this already over-used network. Here we report on new methodology to analyse vulnerabilities and risks due to failures of key locations in the intermodal transport network of Tanzania, including strategic connectivity to neighboring countries. To perform the national-scale risk analysis we will utilize a system-of-systems methodology. The main components of this general risk assessment, when applied to transportation systems, include: (1) Assembling data on: spatially coherent extreme hazards and intermodal transportation networks; (2) Intersecting hazards with transport network models to initiate failure conditions that trigger failure propagation across interdependent networks; (3) Quantifying failure outcomes in terms of social impacts (customers/passengers disrupted) and/or macroeconomic consequences (across multiple sectors); and (4) Simulating, testing and collecting multiple failure scenarios to perform an exhaustive risk assessment in terms of probabilities and consequences. The methodology is being used to pinpoint vulnerability and reduce climate risks to transport infrastructure investments.
Managing Counterparty Risk in an Unstable Financial System
ERIC Educational Resources Information Center
Belmont, David
2012-01-01
The recent flow of headlines excoriating bankers and financiers for malfeasance, fraud, and collusion has been almost biblical in proportion. Counterparties that appeared creditworthy based on financial statements and ratings have revealed that they are impaired either due to computer errors, control failures, malfeasance, or potential regulatory…
Mechanical loading of bovine pericardium accelerates enzymatic degradation.
Ellsmere, J C; Khanna, R A; Lee, J M
1999-06-01
Bioprosthetic heart valves fail as the result of two simultaneous processes: structural deterioration and calcification. Leaflet deterioration and perforation have been correlated with regions of highest stress in the tissue. The failures have long been assumed to be due to simple mechanical fatigue of the collagen fibre architecture; however, we have hypothesized that local stresses-and particularly dynamic stresses-accelerate local proteolysis, leading to tissue failure. This study addresses that hypothesis. Using a novel, custom-built microtensile culture system, strips of bovine pericardium were subjected to static and dynamic loads while being exposed to solutions of microbial collagenase or trypsin (a non-specific proteolytic enzyme). The time to extend to 30% strain (defined here as time to failure) was recorded. After failure, the percentage of collagen solubilized was calculated based on the amount of hydroxyproline present in solution. All data were analyzed by analysis of variance (ANOVA). In collagenase, exposure to static load significantly decreased the time to failure (P < 0.002) due to increased mean rate of collagen solubilization. Importantly, specimens exposed to collagenase and dynamic load failed faster than those exposed to collagenase under the same average static load (P = 0.02). In trypsin, by contrast, static load never led to failure and produced only minimal degradation. Under dynamic load, however, specimens exposed to collagenase, trypsin, and even Tris/CaCl2 buffer solution, all failed. Only samples exposed to Hanks' physiological solution did not fail. Failure of the specimens exposed to trypsin and Tris/CaCl2 suggests that the non-collagenous components and the calcium-dependent proteolytic enzymes present in pericardial tissue may play roles in the pathogenesis of bioprosthetic heart valve degeneration.
Bluett, James; Sergeant, Jamie C; MacGregor, Alex J; Chipping, Jacqueline R; Marshall, Tarnya; Symmons, Deborah P M; Verstappen, Suzanne M M
2018-03-20
Oral methotrexate (MTX) is the first-line therapy for patients with rheumatoid arthritis (RA). However, approximately one quarter of patients discontinue MTX within 12 months. MTX failure, defined as MTX cessation or the addition of another anti-rheumatic drug, is usually due adverse event(s) and/or inefficacy. The aims of this study were to evaluate the rate and predictors of oral MTX failure. Subjects were recruited from the Norfolk Arthritis Register (NOAR), a primary care-based inception cohort of patients with early inflammatory polyarthritis (IP). Subjects were eligible if they commenced MTX as their first DMARD and were recruited between 2000 and 2008. Patient-reported reasons for MTX failure were recorded and categorised as adverse event, inefficacy or other. The addition of a second DMARD during the study period was categorised as failure due to inefficacy. Cox proportional hazards regression models were used to assess potential predictors of MTX failure, accounting for competing risks. A total of 431 patients were eligible. The probability of patients remaining on MTX at 2 years was 82%. Competing risk analysis revealed that earlier MTX failure due to inefficacy was associated with rheumatoid factor (RF) positivity, younger age at symptom onset and higher baseline disease activity (DAS-28). MTX cessation due to an adverse event was less likely in the RF-positive cohort. RF-positive inflammatory polyarthritis patients who are younger with higher baseline disease activity have an increased risk of MTX failure due to inefficacy. Such patients may require combination therapy as a first-line treatment.
150 KVA Samarium Cobalt VSCF Starter Generator Electrical System
1978-12-01
also has protective circuits to limit damage to the system in evpnt tif failure. During normal operation , the system either starts up automatically when...determined during operation due to the external til loop . 4.2. 1. 1. 11 Temperature Sensor Four copper constantan thermocouples are located in stator...design and part of the vibration problem being experienced can be attributed to the shaft critical being too close to the top operating ,)eed range
Dynamic Modeling of ALS Systems
NASA Technical Reports Server (NTRS)
Jones, Harry
2002-01-01
The purpose of dynamic modeling and simulation of Advanced Life Support (ALS) systems is to help design them. Static steady state systems analysis provides basic information and is necessary to guide dynamic modeling, but static analysis is not sufficient to design and compare systems. ALS systems must respond to external input variations and internal off-nominal behavior. Buffer sizing, resupply scheduling, failure response, and control system design are aspects of dynamic system design. We develop two dynamic mass flow models and use them in simulations to evaluate systems issues, optimize designs, and make system design trades. One model is of nitrogen leakage in the space station, the other is of a waste processor failure in a regenerative life support system. Most systems analyses are concerned with optimizing the cost/benefit of a system at its nominal steady-state operating point. ALS analysis must go beyond the static steady state to include dynamic system design. All life support systems exhibit behavior that varies over time. ALS systems must respond to equipment operating cycles, repair schedules, and occasional off-nominal behavior or malfunctions. Biological components, such as bioreactors, composters, and food plant growth chambers, usually have operating cycles or other complex time behavior. Buffer sizes, material stocks, and resupply rates determine dynamic system behavior and directly affect system mass and cost. Dynamic simulation is needed to avoid the extremes of costly over-design of buffers and material reserves or system failure due to insufficient buffers and lack of stored material.
The initial flight anomalies of Skylab 1
NASA Astrophysics Data System (ADS)
At approximately 63 seconds into the flight of Skylab 1 on May 14, 1973, an anomaly occurred which resulted in the complete loss of the meteoroid shield around the orbital workshop. This was followed by the loss of one of the two solar array systems on the workshop and a failure of the inter stage adapter to separate from the S-II stage of the Saturn V launch vehicle. The investigation reported herein identified the most probable cause of this flight anomaly to be the breakup and loss of the meteoroid shield due to aerodynamic loads that were not accounted for in its design. The breakup of the meteoroid shield, in turn, broke the tie downs that secured one of the solar array systems to the workshop. Complete loss of this solar array system occurred at 593 seconds when the exhaust plume of the S-II stage retro-rockets impacted the partially deployed solar array system. Falling debris from the meteoroid shield also damaged the S-II inter stage adapter ordnance system in such a manner as to preclude separation. Of several possible failure modes of the meteoroid shield that were identified, the most probable in this particular flight was internal pressurization of its auxiliary tunnel which acted to force the forward end of the meteoroid shield away from the shell of the workshop and into the supersonic air stream. The pressurization of the auxiliary tunnel was due to the existence of several openings in the aft region of the tunnel. Another possible failure mode was the separation of the leading edge of the meteoroid shield from the shell of the workshop (particularly in the region of the folded ordnance panel) of sufficient extent to admit ram air pressures under the shield.
Malfunction and failure of robotic systems during general surgical procedures.
Agcaoglu, Orhan; Aliyev, Shamil; Taskin, Halit Eren; Chalikonda, Sricharan; Walsh, Matthew; Costedio, Meagan M; Kroh, Matthew; Rogula, Tomasz; Chand, Bipan; Gorgun, Emre; Siperstein, Allan; Berber, Eren
2012-12-01
There has been recent interest in using robots for general surgical procedures. This shift in technique raises the issue of patient safety with automated instrumentation. Although the safety of robotics has been established for urologic procedures, there are scant data on its use in general surgical procedures. The aim of this study is to analyze the incidence of robotic malfunction and its consequences for general surgical procedures. All robotic general surgical procedures performed at a tertiary center between 2008 and 2011 were reviewed from institutional review board (IRB)-approved prospective databases. A total of 223 cases were done robotically, including 102 endocrine, 83 hepatopancreaticobiliary, 17 upper gastrointestinal, and 21 lower gastrointestinal colorectal procedures. There were 10 cases of robotic malfunction (4.5%). These failures were related to robotic instruments (n = 4), optical system (n = 3), robotic arms (n = 2), and robotic console (n = 1). None of these failures led to adverse patient consequences or conversion to open. Six (2.7%) cases were converted to open due to bleeding (n = 3), difficult dissection plane (n = 1), invasion of tumor to surrounding structures (n = 1), and intolerance of pneumoperitoneum due to CO(2) retention (n = 1). There was no mortality, and morbidity was 1% (n = 2). To our knowledge, this is the largest North American report to date on robotic general surgical procedures. Our results show that robotic malfunction occurs in a minority of cases, with no adverse consequences. We believe that awareness of these failures and knowing how to troubleshoot are important to maintain the efficiency of these procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The data accumulated during April 1982 at the photovoltaic project site at the Oklahoma Center for Science and Arts, Oklahoma City, Oklahoma, are presented. Environmental (weather) data are presented graphically. Explanations of irregularities not attributable to weather are provided. Due to a failure of the power conditioning unit, the system was down for the month.
1989-12-01
Bose, Ohio Appni’-sd for puauc t&cw 189 12 29 023 I [ AFIT /GAE /ENY/ 89D-06 A STUDY OF FAILURE CHARACTERISTICS IN THERMOPLASTIC COMPOSITE LAMINATES DUE...distribution unlimited I ,I AFIT / GAE / ENY /89D-06 A STUDY OF FAILURE CHARACTERISTICS IN THERMOPLASTIC COMPOSITE LAMINATES DUE TO AN ECCENTRIC CIRCULAR...the Flight Dynamics Laboratory. Dr. Sandhu provided me with an insight into composite materials, and testing techniques, that will benefit me for a
Distributed Evaluation Functions for Fault Tolerant Multi-Rover Systems
NASA Technical Reports Server (NTRS)
Agogino, Adrian; Turner, Kagan
2005-01-01
The ability to evolve fault tolerant control strategies for large collections of agents is critical to the successful application of evolutionary strategies to domains where failures are common. Furthermore, while evolutionary algorithms have been highly successful in discovering single-agent control strategies, extending such algorithms to multiagent domains has proven to be difficult. In this paper we present a method for shaping evaluation functions for agents that provide control strategies that both are tolerant to different types of failures and lead to coordinated behavior in a multi-agent setting. This method neither relies of a centralized strategy (susceptible to single point of failures) nor a distributed strategy where each agent uses a system wide evaluation function (severe credit assignment problem). In a multi-rover problem, we show that agents using our agent-specific evaluation perform up to 500% better than agents using the system evaluation. In addition we show that agents are still able to maintain a high level of performance when up to 60% of the agents fail due to actuator, communication or controller faults.
Zieliński, Michał; Hartleb, Marek; Sitek, Piotr; Ziora, Dariusz
2017-01-01
This paper presents a case of a young patient with cyanosis and digital clubbing, until then an active, sporty person. He sought medical assistance due to the growing dyspnoea and the drop of effort tolerance. Initially the diagnostic process focused on the confirmation of the suspicion of pulmonary fibrosis or another interstitial lung disease as causes of the respiratory failure. Due to the atypical presentation of the symptoms, reaching the final diagnosis of digestive system disease with lung involvement required a more thorough multifaceted diagnostics of a number of systems and organs.
The Effectiveness of Warranties in the Solar Photovoltaic and Automobile Industries
NASA Astrophysics Data System (ADS)
Formica, Tyler J.
A warranty is an agreement outlined by a manufacturer to a customer that defines performance requirements for a product or service. Although long warranty periods are a useful marketing tool, in 2011 the warranty claims expense was 2.6% of total sales for computer original equipment manufacturers (OEMs) and is over 2% of total sales in many other industries today. Solar PV systems offer inverters with 5-15 year warranties and PV modules with 25-year performance warranties. This is problematic for the return on investment (ROI) of solar PV systems when the modules are still productive and covered under warranty but inverter failures occur due to degradation of electronic components after their warranty has expired. Out-of-warranty inverter failures during the lifetime of solar panels decrease the ROI of solar PV systems significantly and can cause the annual ROI to actually be negative 15-25 years into the lifetime of the system. This thesis analyzes the factors that contribute to designing an optimal warranty period and the relationship between reliability and warranty periods using General Motors (GM) and the solar PV industry as case studies. A return on investment of a solar photovoltaic system is also conducted and the effect of reliability, changing tax credit structures, and failure areas of solar PV systems are analyzed.
Radiation effects and mitigation strategies for modern FPGAs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stettler, M. W.; Caffrey, M. P.; Graham, P. S.
2004-01-01
Field Programmable Gate Array devices have become the technology of choice in small volume modern instrumentation and control systems. These devices have always offered significant advantages in flexibility, and recent advances in fabrication have greatly increased logic capacity, substantially increasing the number of applications for this technology. Unfortunately, the increased density (and corresponding shrinkage of process geometry), has made these devices more susceptible to failure due to external radiation. This has been an issue for space based systems for some time, but is now becoming an issue for terrestrial systems in elevated radiation environments and commercial avionics as well. Characterizingmore » the failure modes of Xilinx FPGAs, and developing mitigation strategies is the subject of ongoing research by a consortium of academic, industrial, and governmental laboratories. This paper presents background information of radiation effects and failure modes, as well as current and future mitigation techniques. In particular, the availability of very large FPGA devices, complete with generous amounts of RAM and embedded processor(s), has led to the implementation of complete digital systems on a single device, bringing issues of system reliability and redundancy management to the chip level. Radiation effects on a single FPGA are increasingly likely to have system level consequences, and will need to be addressed in current and future designs.« less
Patent ductus arteriosus: patho-physiology, hemodynamic effects and clinical complications.
Capozzi, Giovanbattista; Santoro, Giuseppe
2011-10-01
During fetal life, patent arterial duct diverts placental oxygenated blood from the pulmonary artery into the aorta by-passing lungs. After birth, decrease of prostacyclins and prostaglandins concentration usually causes arterial duct closure. This process may be delayed, or may even completely fail in preterm infants with arterial duct still remaining patent. If that happens, blood flow by-pass of the systemic circulation through the arterial duct results in pulmonary overflow and systemic hypoperfusion. When pulmonary flow is 50% higher than systemic flow, a hemodynamic "paradox" results, with an increase of left ventricular output without a subsequent increase of systemic output. Cardiac overload support neuro-humoral effects (activation of sympathetic nervous system and renin-angiotensin system) that finally promote heart failure. Moreover, increased pulmonary blood flow can cause vascular congestion and pulmonary edema. However, the most dangerous effect is cerebral under-perfusion due to diastolic reverse-flow and resulting in cerebral hypoxia. At last, blood flow decreases through the abdominal aorta, reducing perfusion of liver, gut and kidneys and may cause hepatic failure, renal insufficiency and necrotizing enterocolitis. Conclusions Large patent arterial duct may cause life-threatening multi-organ effects. In pre-term infant early diagnosis and timely effective treatment are cornerstones in the prevention of cerebral damage and long-term multi-organ failure.
Information Extraction for System-Software Safety Analysis: Calendar Year 2007 Year-End Report
NASA Technical Reports Server (NTRS)
Malin, Jane T.
2008-01-01
This annual report describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis on the models to identify possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations; 4) perform discrete-time-based simulation on the models to investigate scenarios where these paths may play a role in failures and mishaps; and 5) identify resulting candidate scenarios for software integration testing. This paper describes new challenges in a NASA abort system case, and enhancements made to develop the integrated tool set.
NASA Technical Reports Server (NTRS)
Kaszeta, William J.
1987-01-01
Five different types of public service photovoltaic power/load systems installed in the Gabonese Republic are discussed. The village settings, the systems, performance results and some problems encountered are described. Most of the systems performed well, but some of the systems had problems due to failure of components or installation errors. The project was reasonably successful in collecting and reporting data for system performance evaluation that will be useful for guiding officials and system designers involved in village power applications in developing countries.
The SPS interference problem-electronic system effects and mitigation techniques
NASA Technical Reports Server (NTRS)
Juroshek, J. R.
1980-01-01
The potential for interference between solar power satellites (SPS) and other Earth satellite operations was examined along with interference problems involving specific electronic devices. Conclusions indicate that interference is likely in the 2500 MHz to 2690 MHz direct broadcast satellite band adjacent to SPS. Estimates of the adjacent channel noise from SPS in this band are as high as -124 dBc/4 kHz and -100 dBc/MHz, where dBc represents decibels relative to the total power in the fundamental. A second potential problem is the 7350 MHz, 3d harmonic from SPS that falls within the 7300 MHz to 7450 MHz space to Earth, government, satellite assignment. Catastrophic failures can be produced in integrated circuits when the microwave power levels coupled into inputs and power leads reach 1 to 100 watts. The failures are typically due to bonding wire melting, metallization failures, and junction shorting. Nondestructive interaction or interference, however, generally occurs with coupled power levels of the order of 10 milliwatts. This integration is due to the rectification of microwave energy by the numerous pn junctions within these circuits.
Effects of carbon/graphite fiber contamination on high voltage electrical insulation
NASA Technical Reports Server (NTRS)
Garrity, T.; Eichler, C.
1980-01-01
The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.
NASA Astrophysics Data System (ADS)
Lin, Erica; Li, Yaning; Ortiz, Christine; Boyce, Mary C.
2014-12-01
Geometrically structured interfaces in nature possess enhanced, and often surprising, mechanical properties, and provide inspiration for materials design. This paper investigates the mechanics of deformation and failure mechanisms of suture interface designs through analytical models and experiments on 3D printed polymer physical prototypes. Suture waveforms with generalized trapezoidal geometries (trapezoidal, rectangular, anti-trapezoidal, and triangular) are studied and characterized by several important geometric parameters: the presence or absence of a bonded tip region, the tip angle, and the geometry. It is shown that a wide range (in some cases as great as an order of magnitude) in stiffness, strength, and toughness is achievable dependent on tip bonding, tip angle, and geometry. Suture interfaces with a bonded tip region exhibit a higher initial stiffness due to the greater load bearing by the skeletal teeth, a double peak in the stress-strain curve corresponding to the failure of the bonded tip and the failure of the slanted interface region or tooth, respectively, and an additional failure and toughening mechanism due to the failure of the bonded tip. Anti-trapezoidal geometries promote the greatest amplification of properties for suture interfaces with a bonded tip due the large tip interface area. The tip angle and geometry govern the stress distributions in the teeth and the ratio of normal to shear stresses in the interfacial layers, which together determine the failure mechanism of the interface and/or the teeth. Rectangular suture interfaces fail by simple shearing of the interfaces. Trapezoidal and triangular suture interfaces fail by a combination of shear and tensile normal stresses in the interface, leading to plastic deformation, cavitation events, and subsequent stretching of interface ligaments with mostly elastic deformation in the teeth. Anti-trapezoidal suture interfaces with small tip angles have high stress concentrations in the teeth and fail catastrophically by tooth failure, whereas larger tip angles exhibit a shear failure of the interfaces. Therefore, larger tip angles and trapezoidal or triangular geometries promote graceful failure, and smaller tip angles and anti-trapezoidal geometries promote more brittle-like failure. This dependence is reminiscent of biological systems, which exhibit a range of failure behaviors with limited materials and varied geometry. Triangular geometries uniquely exhibit uniform stress distributions in its teeth and promote the greatest amplification of mechanical properties. In both the bonded and unbonded cases, the predictions from the presented analytical models and experimental results on 3D printed prototypes show excellent agreement. This validates the analytical models and allows for the models to be used as a tool for the design of new materials and interfaces with tailored mechanical behavior.
Detecting Solenoid Valve Deterioration in In-Use Electronic Diesel Fuel Injection Control Systems
Tsai, Hsun-Heng; Tseng, Chyuan-Yow
2010-01-01
The diesel engine is the main power source for most agricultural vehicles. The control of diesel engine emissions is an important global issue. Fuel injection control systems directly affect fuel efficiency and emissions of diesel engines. Deterioration faults, such as rack deformation, solenoid valve failure, and rack-travel sensor malfunction, are possibly in the fuel injection module of electronic diesel control (EDC) systems. Among these faults, solenoid valve failure is most likely to occur for in-use diesel engines. According to the previous studies, this failure is a result of the wear of the plunger and sleeve, based on a long period of usage, lubricant degradation, or engine overheating. Due to the difficulty in identifying solenoid valve deterioration, this study focuses on developing a sensor identification algorithm that can clearly classify the usability of the solenoid valve, without disassembling the fuel pump of an EDC system for in-use agricultural vehicles. A diagnostic algorithm is proposed, including a feedback controller, a parameter identifier, a linear variable differential transformer (LVDT) sensor, and a neural network classifier. Experimental results show that the proposed algorithm can accurately identify the usability of solenoid valves. PMID:22163597
Detecting solenoid valve deterioration in in-use electronic diesel fuel injection control systems.
Tsai, Hsun-Heng; Tseng, Chyuan-Yow
2010-01-01
The diesel engine is the main power source for most agricultural vehicles. The control of diesel engine emissions is an important global issue. Fuel injection control systems directly affect fuel efficiency and emissions of diesel engines. Deterioration faults, such as rack deformation, solenoid valve failure, and rack-travel sensor malfunction, are possibly in the fuel injection module of electronic diesel control (EDC) systems. Among these faults, solenoid valve failure is most likely to occur for in-use diesel engines. According to the previous studies, this failure is a result of the wear of the plunger and sleeve, based on a long period of usage, lubricant degradation, or engine overheating. Due to the difficulty in identifying solenoid valve deterioration, this study focuses on developing a sensor identification algorithm that can clearly classify the usability of the solenoid valve, without disassembling the fuel pump of an EDC system for in-use agricultural vehicles. A diagnostic algorithm is proposed, including a feedback controller, a parameter identifier, a linear variable differential transformer (LVDT) sensor, and a neural network classifier. Experimental results show that the proposed algorithm can accurately identify the usability of solenoid valves.
NASA Astrophysics Data System (ADS)
Ji, Yunguang; Xu, Yangyang; Li, Hongtao; Oklejas, Michael; Xue, Shuqi
2018-01-01
A new type of hydraulic turbocharger energy recovery system was designed and applied in the decarbonisation process by propylene carbonate of a 100k tons ammonia synthesis system firstly in China. Compared with existing energy recovery devices, hydraulic turbocharger energy recovery system runs more smoothly, has lower failure rate, longer service life and greater comprehensive benefits due to its unique structure, simpler adjustment process and better adaptability to fluid fluctuation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, S; Guerrero, M; Zhang, B
Purpose: To implement a comprehensive non-measurement-based verification program for patient-specific IMRT QA Methods: Based on published guidelines, a robust IMRT QA program should assess the following components: 1) accuracy of dose calculation, 2) accuracy of data transfer from the treatment planning system (TPS) to the record-and-verify (RV) system, 3) treatment plan deliverability, and 4) accuracy of plan delivery. Results: We have implemented an IMRT QA program that consist of four components: 1) an independent re-calculation of the dose distribution in the patient anatomy with a commercial secondary dose calculation program: Mobius3D (Mobius Medical Systems, Houston, TX), with dose accuracy evaluationmore » using gamma analysis, PTV mean dose, PTV coverage to 95%, and organ-at-risk mean dose; 2) an automated in-house-developed plan comparison system that compares all relevant plan parameters such as MU, MLC position, beam iso-center position, collimator, gantry, couch, field size settings, and bolus placement, etc. between the plan and the RV system; 3) use of the RV system to check the plan deliverability and further confirm using “mode-up” function on treatment console for plans receiving warning; and 4) implementation of a comprehensive weekly MLC QA, in addition to routine accelerator monthly and daily QA. Among 1200 verifications, there were 9 cases of suspicious calculations, 5 cases of delivery failure, no data transfer errors, and no failure of weekly MLC QA. These 9 suspicious cases were due to the PTV extending to the skin or to heterogeneity correction effects, which would not have been caught using phantom measurement-based QA. The delivery failure was due to the rounding variation of MLC position between the planning system and RV system. Conclusion: A very efficient, yet comprehensive, non-measurement-based patient-specific QA program has been implemented and used clinically for about 18 months with excellent results.« less
A bivariate model for analyzing recurrent multi-type automobile failures
NASA Astrophysics Data System (ADS)
Sunethra, A. A.; Sooriyarachchi, M. R.
2017-09-01
The failure mechanism in an automobile can be defined as a system of multi-type recurrent failures where failures can occur due to various multi-type failure modes and these failures are repetitive such that more than one failure can occur from each failure mode. In analysing such automobile failures, both the time and type of the failure serve as response variables. However, these two response variables are highly correlated with each other since the timing of failures has an association with the mode of the failure. When there are more than one correlated response variables, the fitting of a multivariate model is more preferable than separate univariate models. Therefore, a bivariate model of time and type of failure becomes appealing for such automobile failure data. When there are multiple failure observations pertaining to a single automobile, such data cannot be treated as independent data because failure instances of a single automobile are correlated with each other while failures among different automobiles can be treated as independent. Therefore, this study proposes a bivariate model consisting time and type of failure as responses adjusted for correlated data. The proposed model was formulated following the approaches of shared parameter models and random effects models for joining the responses and for representing the correlated data respectively. The proposed model is applied to a sample of automobile failures with three types of failure modes and up to five failure recurrences. The parametric distributions that were suitable for the two responses of time to failure and type of failure were Weibull distribution and multinomial distribution respectively. The proposed bivariate model was programmed in SAS Procedure Proc NLMIXED by user programming appropriate likelihood functions. The performance of the bivariate model was compared with separate univariate models fitted for the two responses and it was identified that better performance is secured by the bivariate model. The proposed model can be used to determine the time and type of failure that would occur in the automobiles considered here.
Asdonk, T; Nickenig, G; Hammerstingl, C
2014-10-01
Mitral regurgitation (MR) is a frequent valve disorder in elderly patients, often accompanied by multiple comorbidities such as renal impairment. In these patients percutaneous mitral valve (MV) repair has become an established treatment option but the role of MR on renal dysfunction is not yet well defined. We here report on two cases presenting with severe MR and progressive renal failure caused by cardio renal syndrome, in which percutaneous MV treatment with the MitraClip system significantly improved renal function. These findings suggest that interventional MV repair can prevent progression of renal deterioration in patients suffering from combined advanced heart and renal failure. Further clinical studies are necessary to support our finding and to answer the question whether optimizing renal function by implantation of the MitraClip device is also of prognostic relevance in these patients. © 2014 Wiley Periodicals, Inc.
Effluent quality from 200 on-site sewage systems: design values for guidelines.
Charles, K J; Ashbolt, N J; Roser, D J; McGuinness, R; Deere, D A
2005-01-01
The quality of effluent from an on-site sewage treatment system is a critical factor in designing the disposal area and, hence, ensuring the sustained performance of the system. Contaminant concentrations in effluent are typically specified in regulatory guidelines or standards; however, the accuracy of these guideline values are brought into question due to the poor performance of septic tanks and the high failure rates of disposal systems reported here and elsewhere. Results from studies of septic tank effluent quality indicated that the effluent is of poorer quality than currently suggested by guidelines. Aerated wastewater treatment systems were found to perform to accreditation guidelines; however, insufficient nutrient data is presently available to assess nutrient loads. It is proposed that the 80th percentile of system performance be adopted as the design value for sizing effluent disposal areas to minimise failure associated with overloading. For septic tanks this equates to 660 mg L(-1) SS, 330 mg L(-1) BOD, 250 mg L(-1) TN and 36 mg L(-1) TP.
A Reliable Wireless Control System for Tomato Hydroponics
Ibayashi, Hirofumi; Kaneda, Yukimasa; Imahara, Jungo; Oishi, Naoki; Kuroda, Masahiro; Mineno, Hiroshi
2016-01-01
Agricultural systems using advanced information and communication (ICT) technology can produce high-quality crops in a stable environment while decreasing the need for manual labor. The system collects a wide variety of environmental data and provides the precise cultivation control needed to produce high value-added crops; however, there are the problems of packet transmission errors in wireless sensor networks or system failure due to having the equipment in a hot and humid environment. In this paper, we propose a reliable wireless control system for hydroponic tomato cultivation using the 400 MHz wireless band and the IEEE 802.15.6 standard. The 400 MHz band, which is lower than the 2.4 GHz band, has good obstacle diffraction, and zero-data-loss communication is realized using the guaranteed time-slot method supported by the IEEE 802.15.6 standard. In addition, this system has fault tolerance and a self-healing function to recover from faults such as packet transmission failures due to deterioration of the wireless communication quality. In our basic experiments, the 400 MHz band wireless communication was not affected by the plants’ growth, and the packet error rate was less than that of the 2.4 GHz band. In summary, we achieved a real-time hydroponic liquid supply control with no data loss by applying a 400 MHz band WSN to hydroponic tomato cultivation. PMID:27164105
A Reliable Wireless Control System for Tomato Hydroponics.
Ibayashi, Hirofumi; Kaneda, Yukimasa; Imahara, Jungo; Oishi, Naoki; Kuroda, Masahiro; Mineno, Hiroshi
2016-05-05
Agricultural systems using advanced information and communication (ICT) technology can produce high-quality crops in a stable environment while decreasing the need for manual labor. The system collects a wide variety of environmental data and provides the precise cultivation control needed to produce high value-added crops; however, there are the problems of packet transmission errors in wireless sensor networks or system failure due to having the equipment in a hot and humid environment. In this paper, we propose a reliable wireless control system for hydroponic tomato cultivation using the 400 MHz wireless band and the IEEE 802.15.6 standard. The 400 MHz band, which is lower than the 2.4 GHz band, has good obstacle diffraction, and zero-data-loss communication is realized using the guaranteed time-slot method supported by the IEEE 802.15.6 standard. In addition, this system has fault tolerance and a self-healing function to recover from faults such as packet transmission failures due to deterioration of the wireless communication quality. In our basic experiments, the 400 MHz band wireless communication was not affected by the plants' growth, and the packet error rate was less than that of the 2.4 GHz band. In summary, we achieved a real-time hydroponic liquid supply control with no data loss by applying a 400 MHz band WSN to hydroponic tomato cultivation.
The shock and spall response of AA 7010-T7651
NASA Astrophysics Data System (ADS)
Hazell, Paul; Appleby-Thomas, Gareth; Wood, David; Painter, Jonathan
2013-06-01
Aluminium alloys are used extensively in armour. Their use as armour materials is primarily due to their relatively low densities and their high strength characteristics. The aerospace-grade 7000-series alloy Al7010-T7651 is one possible contender for armour. In this study a series of plate-impact experiments were undertaken to investigate the behaviour of this alloy under shock. Manganin stress gauges and a heterodyne velocimeter system were used to interrogate both strength and dynamic tensile failure (spall) respectively; with microscopic analysis of recovered samples providing insight into the development of failure in the material.
Maximum likelihood estimation for life distributions with competing failure modes
NASA Technical Reports Server (NTRS)
Sidik, S. M.
1979-01-01
Systems which are placed on test at time zero, function for a period and die at some random time were studied. Failure may be due to one of several causes or modes. The parameters of the life distribution may depend upon the levels of various stress variables the item is subject to. Maximum likelihood estimation methods are discussed. Specific methods are reported for the smallest extreme-value distributions of life. Monte-Carlo results indicate the methods to be promising. Under appropriate conditions, the location parameters are nearly unbiased, the scale parameter is slight biased, and the asymptotic covariances are rapidly approached.
NASA Technical Reports Server (NTRS)
Deacetis, Louis A.
1987-01-01
The elements of a simulation program written in Ada were developed. The program will eventually serve as a data generator of typical readings from various space station equipment involved with Communications and Tracking, and will simulate various scenarios that may arise due to equipment malfunction or failure, power failure, etc. In addition, an evaluation of the Ada language was made from the viewpoint of a FORTRAN programmer learning Ada for the first time. Various strengths and difficulties associated with the learning and use of Ada are considered.
Mahomed, Sharana; Dlamini-Mvelase, Nomonde R; Dlamini, Moses; Mlisana, Koleka
2017-01-01
For the optimal recovery of Mycobacterium tuberculosis from the BACTEC™ Mycobacterium Growth Indicator Tube 960™ system, an incubation period of 42-56 days is recommended by the manufacturer. Due to logistical reasons, it is common practice to follow an incubation period of 42 days. We undertook a retrospective study to document positive Mycobacterium Growth Indicator Tube cultures beyond the 42-day incubation period. In total, 98/110 (89%) were positive for M. tuberculosis complex. This alerted us to M. tuberculosis growth detection failure at 42 days.
Modeling Security Aspects of Network
NASA Astrophysics Data System (ADS)
Schoch, Elmar
With more and more widespread usage of computer systems and networks, dependability becomes a paramount requirement. Dependability typically denotes tolerance or protection against all kinds of failures, errors and faults. Sources of failures can basically be accidental, e.g., in case of hardware errors or software bugs, or intentional due to some kind of malicious behavior. These intentional, malicious actions are subject of security. A more complete overview on the relations between dependability and security can be found in [31]. In parallel to the increased use of technology, misuse also has grown significantly, requiring measures to deal with it.
NASA Technical Reports Server (NTRS)
Naumann, R. J.; Oran, W. A.; Whymark, R. R.; Rey, C.
1981-01-01
The single axis acoustic levitator that was flown on SPAR VI malfunctioned. The results of a series of tests, analyses, and investigation of hypotheses that were undertaken to determine the probable cause of failure are presented, together with recommendations for future flights of the apparatus. The most probable causes of the SPAR VI failure were lower than expected sound intensity due to mechanical degradation of the sound source, and an unexpected external force that caused the experiment sample to move radially and eventually be lost from the acoustic energy well.
Semiparametric regression analysis of failure time data with dependent interval censoring.
Chen, Chyong-Mei; Shen, Pao-Sheng
2017-09-20
Interval-censored failure-time data arise when subjects are examined or observed periodically such that the failure time of interest is not examined exactly but only known to be bracketed between two adjacent observation times. The commonly used approaches assume that the examination times and the failure time are independent or conditionally independent given covariates. In many practical applications, patients who are already in poor health or have a weak immune system before treatment usually tend to visit physicians more often after treatment than those with better health or immune system. In this situation, the visiting rate is positively correlated with the risk of failure due to the health status, which results in dependent interval-censored data. While some measurable factors affecting health status such as age, gender, and physical symptom can be included in the covariates, some health-related latent variables cannot be observed or measured. To deal with dependent interval censoring involving unobserved latent variable, we characterize the visiting/examination process as recurrent event process and propose a joint frailty model to account for the association of the failure time and visiting process. A shared gamma frailty is incorporated into the Cox model and proportional intensity model for the failure time and visiting process, respectively, in a multiplicative way. We propose a semiparametric maximum likelihood approach for estimating model parameters and show the asymptotic properties, including consistency and weak convergence. Extensive simulation studies are conducted and a data set of bladder cancer is analyzed for illustrative purposes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Independent Orbiter Assessment (IOA): Analysis of the DPS subsystem
NASA Technical Reports Server (NTRS)
Lowery, H. J.; Haufler, W. A.; Pietz, K. C.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) is presented. The IOA approach features a top-down analysis of the hardware to independently determine failure modes, criticality, and potential critical items. The independent analysis results corresponding to the Orbiter Data Processing System (DPS) hardware are documented. The DPS hardware is required for performing critical functions of data acquisition, data manipulation, data display, and data transfer throughout the Orbiter. Specifically, the DPS hardware consists of the following components: Multiplexer/Demultiplexer (MDM); General Purpose Computer (GPC); Multifunction CRT Display System (MCDS); Data Buses and Data Bus Couplers (DBC); Data Bus Isolation Amplifiers (DBIA); Mass Memory Unit (MMU); and Engine Interface Unit (EIU). The IOA analysis process utilized available DPS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Due to the extensive redundancy built into the DPS the number of critical items are few. Those identified resulted from premature operation and erroneous output of the GPCs.
Quantifying Safety Margin Using the Risk-Informed Safety Margin Characterization (RISMC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, David; Bucknor, Matthew; Brunett, Acacia
2015-04-26
The Risk-Informed Safety Margin Characterization (RISMC), developed by Idaho National Laboratory as part of the Light-Water Reactor Sustainability Project, utilizes a probabilistic safety margin comparison between a load and capacity distribution, rather than a deterministic comparison between two values, as is usually done in best-estimate plus uncertainty analyses. The goal is to determine the failure probability, or in other words, the probability of the system load equaling or exceeding the system capacity. While this method has been used in pilot studies, there has been little work conducted investigating the statistical significance of the resulting failure probability. In particular, it ismore » difficult to determine how many simulations are necessary to properly characterize the failure probability. This work uses classical (frequentist) statistics and confidence intervals to examine the impact in statistical accuracy when the number of simulations is varied. Two methods are proposed to establish confidence intervals related to the failure probability established using a RISMC analysis. The confidence interval provides information about the statistical accuracy of the method utilized to explore the uncertainty space, and offers a quantitative method to gauge the increase in statistical accuracy due to performing additional simulations.« less
NASA Technical Reports Server (NTRS)
Lee, H. H.; Hyer, M. W.
1992-01-01
The postbuckling failure of square composite plates with central holes is analyzed numerically and experimentally. The particular plates studies have stacking sequences of: (+ and - 45/0/90)(sub 2S); (+ and - 45/0(sub 2))(sub 2S); (+ and - 45/0(sub 6))(sub S); and (+ and - 45)(sub 4S). A simple plate geometry, one with a hole diameter to plate width ratio of 0.3 is compared. Failure load, failure mode, and failure location are predicted numerically by using the finite element method. Predictions are compared with experimental results. In numerical failure analysis the interlaminar shear stresses, as well as the inplane stresses are taken into account. An issue addressed in this study is the possible mode shape change of the plate during loading. It is predicted that the first three laminates fail due to excessive stresses in the fiber direction, and more importantly, that the load level is independent of whether the laminate is deformed in a one-half or two-half wave configuration. It is predicted that the fourth laminate fails due to excessive inplane shear stress. Interlaminar shear failure is not predicted for any laminates. For the first two laminates the experimental observations correlated well with the predictions. Experimentally, the third laminate failed along the side support due to interlaminar shear strength S(sub 23). The fourth experimental laminate failed due to inplane shear in the location predicted, however material softening resulted in a different failure load from predictions.
Haul truck tire dynamics due to tire condition
NASA Astrophysics Data System (ADS)
Vaghar Anzabi, R.; Nobes, D. S.; Lipsett, M. G.
2012-05-01
Pneumatic tires are costly components on large off-road haul trucks used in surface mining operations. Tires are prone to damage during operation, and these events can lead to injuries to personnel, loss of equipment, and reduced productivity. Damage rates have significant variability, due to operating conditions and a range of tire fault modes. Currently, monitoring of tire condition is done by physical inspection; and the mean time between inspections is often longer than the mean time between incipient failure and functional failure of the tire. Options for new condition monitoring methods include off-board thermal imaging and camera-based optical methods for detecting abnormal deformation and surface features, as well as on-board sensors to detect tire faults during vehicle operation. Physics-based modeling of tire dynamics can provide a good understanding of the tire behavior, and give insight into observability requirements for improved monitoring systems. This paper describes a model to simulate the dynamics of haul truck tires when a fault is present to determine the effects of physical parameter changes that relate to faults. To simulate the dynamics, a lumped mass 'quarter-vehicle' model has been used to determine the response of the system to a road profile when a failure changes the original properties of the tire. The result is a model of tire vertical displacement that can be used to detect a fault, which will be tested under field conditions in time-varying conditions.
Pulmonary hypertension and predominant right heart failure in thyrotoxicosis.
Paran, Yael; Nimrod, Adi; Goldin, Yelena; Justo, Dan
2006-05-01
In this report we discuss a patient with predominant right heart failure and pulmonary hypertension, caused by thyrotoxicosis due to Graves disease, which deteriorated to asystole, due to amiodarone administration for rapid atrial fibrillation.
NASA Astrophysics Data System (ADS)
Vandre, Eric
2014-11-01
Dynamic wetting is crucial to processes where a liquid displaces another fluid along a solid surface, such as the deposition of a coating liquid onto a moving substrate. Dynamic wetting fails when process speed exceeds some critical value, leading to incomplete fluid displacement and transient phenomena that impact a variety of applications, such as microfluidic devices, oil-recovery systems, and splashing droplets. Liquid coating processes are particularly sensitive to wetting failure, which can induce air entrainment and other catastrophic coating defects. Despite the industrial incentives for careful control of wetting behavior, the hydrodynamic factors that influence the transition to wetting failure remain poorly understood from empirical and theoretical perspectives. This work investigates the fundamentals of wetting failure in a variety of systems that are relevant to industrial coating flows. A hydrodynamic model is developed where an advancing fluid displaces a receding fluid along a smooth, moving substrate. Numerical solutions predict the onset of wetting failure at a critical substrate speed, which coincides with a turning point in the steady-state solution path for a given set of system parameters. Flow-field analysis reveals a physical mechanism where wetting failure results when capillary forces can no longer support the pressure gradients necessary to steadily displace the receding fluid. Novel experimental systems are used to measure the substrate speeds and meniscus shapes associated with the onset of air entrainment during wetting failure. Using high-speed visualization techniques, air entrainment is identified by the elongation of triangular air films with system-dependent size. Air films become unstable to thickness perturbations and ultimately rupture, leading to the entrainment of air bubbles. Meniscus confinement in a narrow gap between the substrate and a stationary plate is shown to delay air entrainment to higher speeds for a variety of water/glycerol solutions. In addition, liquid pressurization (relative to ambient air) further postpones air entrainment when the meniscus is located near a sharp corner along the plate. Recorded critical speeds compare well to predictions from the model, supporting the hydrodynamic mechanism for the onset of wetting failure. Lastly, the industrial practice of curtain coating is investigated using the hydrodynamic model. Due to the complexity of this system, a new computational approach is developed combining a finite element method and lubrication theory in order to improve the efficiency of the numerical analysis. Results show that the onset of wetting failure varies strongly with the operating conditions of this system. In addition, stresses from the air flow dramatically affect the steady wetting behavior of curtain coating. Ultimately, these findings emphasize the important role of two-fluid displacement mechanics in high-speed wetting systems.
Safe structures for future aircraft
NASA Technical Reports Server (NTRS)
Mccomb, H. G., Jr.
1983-01-01
The failure mechanisms, design lessons, and test equipment employed by NASA in establishing the airworthiness and crashworthiness of aircraft components for commercial applications are described. The composites test programs have progressed to medium primary structures such as stabilizers and a vertical fin. The failures encountered to date have been due to the nonyielding nature of composites, which do not diffuse loads like metals, and the presence of eccentricities, irregular shapes, stiffness changes, and discontinuities that cause tension and shear. Testing to failure, which always occurred in first tests before the design loads were reached, helped identify design changes and reinforcements that produced successful products. New materials and NDE techniques are identified, together with aircraft structural design changes that offer greater protection to the passengers, fuel antimisting agents, and landing gear systems.
Kalya, Anantharam; Jaroszewski, Dawn; Pajaro, Octavio; Scott, Robert; Gopalan, Radha; Kasper, Diane; Arabia, Francisco
2013-01-01
Cardiac allograft rejection and failure may require mechanical circulatory support as bridge-to-retransplantation. Prognosis in this patient group is poor and implantable ventricular assist devices have had limited success due to organ failure associated with the high dose immunosuppression required to treat ongoing rejection. We present a case from our institution and the world-wide experience utilizing the SynCardia CardioWest Total Artificial Heart (TAH-t; SynCardia Systems, Inc., Tucson, AZ, USA) for replacement of the failing graft, recovery of patient and end-organ failure with ultimate bridge to retransplantation. We present our experience and review of world-wide experience for use of TAH-t in this type patient. © 2013 John Wiley & Sons A/S.
[A case of Legionella pneumonia with multiple organ failure].
Li, Jiali; Wen, Rui; Deng, Hong; Li, Qian
2016-06-28
Legionella pneumonia (LP) is a rare systemic infectious disease, which is often misdiagnosed by clinicians due to the atypical symptoms. A middle-aged man who suffered from fever and dyspnea was diagnosed as community acquired pneumonia (CAP) in Changsha Central Hospital in March 2015. The treatment was unsatisfied firstly. The patients showed further symptoms of rhabdomyolysis, acute liver and renal failure, and impaired neural functions, who was diagnosed as LP with multiple organ failure based on a positive test for Legionella antibody. The patient was recovered after treated with moxifloxacin combined with azithromycin and continuous renal replacement therapy. LP should be paid attention when patient was diagnosed as CAP and failed to be treated. The satisfied outcome is achieved after application of macrolide, quinolones and comprehensive treatments.
NASA Technical Reports Server (NTRS)
Wilmot, Jonathan
2005-01-01
The contents include the following: High availability. Hardware is in harsh environment. Flight processor (constraints) very widely due to power and weight constraints. Software must be remotely modifiable and still operate while changes are being made. Many custom one of kind interfaces for one of a kind missions. Sustaining engineering. Price of failure is high, tens to hundreds of millions of dollars.
Orbital debris hazard insights from spacecraft anomalies studies
NASA Astrophysics Data System (ADS)
McKnight, Darren S.
2016-09-01
Since the dawning of the space age space operators have been tallying spacecraft anomalies and failures then using these insights to improve the space systems and operations. As space systems improved and their lifetimes increased, the anomaly and failure modes have multiplied. Primary triggers for space anomalies and failures include design issues, space environmental effects, and satellite operations. Attempts to correlate anomalies to the orbital debris environment have started as early as the mid-1990's. Early attempts showed tens of anomalies correlated well to altitudes where the cataloged debris population was the highest. However, due to the complexity of tracing debris impacts to mission anomalies, these analyses were found to be insufficient to prove causation. After the fragmentation of the Chinese Feng-Yun satellite in 2007, it was hypothesized that the nontrackable fragments causing anomalies in LEO would have increased significantly from this event. As a result, debris-induced anomalies should have gone up measurably in the vicinity of this breakup. Again, the analysis provided some subtle evidence of debris-induced anomalies but it was not convincing. The continued difficulty in linking debris flux to satellite anomalies and failures prompted the creation of a series of spacecraft anomalies and failure workshops to investigate the identified shortfalls. These gatherings have produced insights into why this process is not straightforward. Summaries of these studies and workshops are presented and observations made about how to create solutions for anomaly attribution, especially as it relates to debris-induced spacecraft anomalies and failures.
Orion GN&C Fault Management System Verification: Scope And Methodology
NASA Technical Reports Server (NTRS)
Brown, Denise; Weiler, David; Flanary, Ronald
2016-01-01
In order to ensure long-term ability to meet mission goals and to provide for the safety of the public, ground personnel, and any crew members, nearly all spacecraft include a fault management (FM) system. For a manned vehicle such as Orion, the safety of the crew is of paramount importance. The goal of the Orion Guidance, Navigation and Control (GN&C) fault management system is to detect, isolate, and respond to faults before they can result in harm to the human crew or loss of the spacecraft. Verification of fault management/fault protection capability is challenging due to the large number of possible faults in a complex spacecraft, the inherent unpredictability of faults, the complexity of interactions among the various spacecraft components, and the inability to easily quantify human reactions to failure scenarios. The Orion GN&C Fault Detection, Isolation, and Recovery (FDIR) team has developed a methodology for bounding the scope of FM system verification while ensuring sufficient coverage of the failure space and providing high confidence that the fault management system meets all safety requirements. The methodology utilizes a swarm search algorithm to identify failure cases that can result in catastrophic loss of the crew or the vehicle and rare event sequential Monte Carlo to verify safety and FDIR performance requirements.
Error, blame, and the law in health care--an antipodean perspective.
Runciman, William B; Merry, Alan F; Tito, Fiona
2003-06-17
Patients are frequently harmed by problems arising from the health care process itself. Addressing these problems requires understanding the role of errors, violations, and system failures in their genesis. Problem-solving is inhibited by a tendency to blame those involved, often inappropriately. This has been aggravated by the need to attribute blame before compensation can be obtained through tort and the human failing of attributing blame simply because there has been a serious outcome. Blaming and punishing for errors that are made by well-intentioned people working in the health care system drives the problem of iatrogenic harm underground and alienates people who are best placed to prevent such problems from recurring. On the other hand, failure to assign blame when it is due is also undesirable and erodes trust in the medical profession. Understanding the distinction between blameworthy behavior and inevitable human errors and appreciating the systemic factors that underlie most failures in complex systems are essential for the response to a harmed patient to be informed, fair, and effective in improving safety. It is important to meet society's needs to blame and exact retribution when appropriate. However, this should not be a prerequisite for compensation, which should be appropriately structured, fair, timely, and, ideally, properly funded as an intrinsic part of health care and social security systems.
Effectiveness of infliximab after adalimumab failure in Crohn's disease.
Chaparro, María; Andreu, Montserrat; Barreiro-de Acosta, Manuel; García-Planella, Esther; Ricart, Elena; Domènech, Eugeni; Esteve, María; Merino, Olga; Nos, Pilar; Peñalva, Mireia; Gisbert, Javier P
2012-10-07
To evaluate the effectiveness of infliximab as a second-line therapy in Crohn's disease patients after adalimumab failure. A historical cohort study in a community-based gastroenterology practice evaluated Crohn's disease patients treated with infliximab (induction plus maintenance) after adalimumab failure. Patients were identified using a large Spanish database (ENEIDA). We included 15 Crohn's disease patients who received infliximab after adalimumab failure. Five patients discontinued adalimumab due to loss of response, 3 due to adverse events and 7 due to partial response. After infliximab therapy was started, all patients who had interrupted adalimumab due to loss of efficacy regained response. All patients who discontinued adalimumab due to adverse events responded to infliximab and maintained this response; one of these patients had an uneventful course on infliximab, but 2 developed adverse events. None of the 7 patients who interrupted adalimumab due to partial response reached remission with infliximab. Switching from adalimumab to infliximab may be useful in patients who develop adverse effects or loss of response, however, the benefit of infliximab in primary nonresponders was not established.
Effectiveness of infliximab after adalimumab failure in Crohn's disease
Chaparro, María; Andreu, Montserrat; Barreiro-de Acosta, Manuel; García-Planella, Esther; Ricart, Elena; Domènech, Eugeni; Esteve, María; Merino, Olga; Nos, Pilar; Peñalva, Mireia; Gisbert, Javier P
2012-01-01
AIM: To evaluate the effectiveness of infliximab as a second-line therapy in Crohn’s disease patients after adalimumab failure. METHODS: A historical cohort study in a community-based gastroenterology practice evaluated Crohn’s disease patients treated with infliximab (induction plus maintenance) after adalimumab failure. Patients were identified using a large Spanish database (ENEIDA). RESULTS: We included 15 Crohn’s disease patients who received infliximab after adalimumab failure. Five patients discontinued adalimumab due to loss of response, 3 due to adverse events and 7 due to partial response. After infliximab therapy was started, all patients who had interrupted adalimumab due to loss of efficacy regained response. All patients who discontinued adalimumab due to adverse events responded to infliximab and maintained this response; one of these patients had an uneventful course on infliximab, but 2 developed adverse events. None of the 7 patients who interrupted adalimumab due to partial response reached remission with infliximab. CONCLUSION: Switching from adalimumab to infliximab may be useful in patients who develop adverse effects or loss of response, however, the benefit of infliximab in primary nonresponders was not established. PMID:23066316
System safety management: A new discipline
NASA Technical Reports Server (NTRS)
Pope, W. C.
1971-01-01
The systems theory is discussed in relation to safety management. It is suggested that systems safety management, as a new discipline, holds great promise for reducing operating errors, conserving labor resources, avoiding operating costs due to mistakes, and for improving managerial techniques. It is pointed out that managerial failures or system breakdowns are the basic reasons for human errors and condition defects. In this respect, a recommendation is made that safety engineers stop visualizing the problem only with the individual (supervisor or employee) and see the problem from the systems point of view.
Inductive System Monitors Tasks
NASA Technical Reports Server (NTRS)
2008-01-01
The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of the actual failure event. In the Aeronautics Research Mission Directorate, IMS successfully performed real-time engine health analysis. IMS was able to detect simulated failures and actual engine anomalies in an F/A-18 aircraft during the course of 25 test flights. IMS is also being used in colla
2010-02-01
condition, etc.) [ Fenske , 2006]. The failures due to friction and wear range across scale boundaries from nanoscale tribology at asperities to...Coatings for Machines and Mechanisnms Operating Under Extreme Conditions (A. review), Journal of Friction and Wear, 25 (3), 78. 2. Fenske G., Robert E
Background: Electronic health records (EHRs) are now a ubiquitous component of the US healthcare system and are attractive for secondary data analysis as they contain detailed and longitudinal clinical records on potentially millions of individuals. However, due to their relative...
Use of Failure in IS Development Statistics: Lessons for IS Curriculum Design
ERIC Educational Resources Information Center
Longenecker, Herbert H., Jr.; Babb, Jeffry; Waguespack, Leslie; Tastle, William; Landry, Jeff
2016-01-01
The evolution of computing education reflects the history of the professional practice of computing. Keeping computing education current has been a major challenge due to the explosive advances in technologies. Academic programs in Information Systems, a long-standing computing discipline, develop and refine the theory and practice of computing…
49 CFR Appendix C to Part 236 - Safety Assurance Criteria and Processes
Code of Federal Regulations, 2010 CFR
2010-10-01
... system (all its elements including hardware and software) must be designed to assure safe operation with... unsafe errors in the software due to human error in the software specification, design, or coding phases... (hardware or software, or both) are used in combination to ensure safety. If a common mode failure exists...
Requirement Generation for Space Infrastructure Systems
NASA Astrophysics Data System (ADS)
Hempsell, M.
Despite heavy investment, in the half-century period between 1970 and 2020 there will almost no progress in the capability provided by the space infrastructure. It is argued that this is due to a failure during the requirement generation phase of the infrastructure's elements, a failure that is primarily due to following the accepted good practice of involving stakeholders while establishing a mission based set of technical requirements. This argument is supported by both a consideration of the history of the requirement generation phase of past space infrastructure projects, in particular the Space Shuttle, and an analysis of the interactions of the stakeholders during this phase. Traditional stakeholder involvement only works well in mature infrastructures where investment aims to make minor improvements, whereas space activity is still in the early experimental stages and is open to major new initiatives that aim to radically change the way we work in space. A new approach to requirement generation is proposed, which is more appropriate to these current circumstances. This uses a methodology centred on the basic functions the system is intended to perform rather than its expected missions.
Reconfigurable Control with Neural Network Augmentation for a Modified F-15 Aircraft
NASA Technical Reports Server (NTRS)
Burken, John J.; Williams-Hayes, Peggy; Kaneshige, John T.; Stachowiak, Susan J.
2006-01-01
Description of the performance of a simplified dynamic inversion controller with neural network augmentation follows. Simulation studies focus on the results with and without neural network adaptation through the use of an F-15 aircraft simulator that has been modified to include canards. Simulated control law performance with a surface failure, in addition to an aerodynamic failure, is presented. The aircraft, with adaptation, attempts to minimize the inertial cross-coupling effect of the failure (a control derivative anomaly associated with a jammed control surface). The dynamic inversion controller calculates necessary surface commands to achieve desired rates. The dynamic inversion controller uses approximate short period and roll axis dynamics. The yaw axis controller is a sideslip rate command system. Methods are described to reduce the cross-coupling effect and maintain adequate tracking errors for control surface failures. The aerodynamic failure destabilizes the pitching moment due to angle of attack. The results show that control of the aircraft with the neural networks is easier (more damped) than without the neural networks. Simulation results show neural network augmentation of the controller improves performance with aerodynamic and control surface failures in terms of tracking error and cross-coupling reduction.
Early initiation of beta blockade in heart failure: issues and evidence.
Williams, Randall E
2005-09-01
Despite clinical trials demonstrating that inhibitors of the renin-angiotensin and sympathetic nervous systems can reduce the mortality and morbidity risk associated with heart failure, these drugs have remained underutilized in general clinical practice. In particular, many patients with heart failure due to left ventricular systolic dysfunction fail to receive beta blockers, although this class of drugs, as well as other antihypertensive agents such as angiotensin-converting enzyme inhibitors or angiotensin receptor blockers, are recommended as part of routine heart failure therapy by national expert consensus guidelines. In-hospital initiation of beta-blocker therapy may improve long-term utilization by physicians and compliance by patients through obviating many of the misperceived dangers associated with beta blockade. The following review of the clinical trial data from the Randomized Evaluation of Strategies for Left Ventricular Dysfunction (RESOLVD) trial, the Metoprolol Controlled-Release Randomized Intervention Trial in Heart Failure (MERIT-HF), the Cardiac Insufficiency Bisoprolol Study II (CIBIS-II), the Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) trial, and the Initiation Management Predischarge Process for Assessment of Carvedilol Therapy for Heart Failure (IMPACT-HF) trial on the efficacy, safety, and tolerability of beta blockers indicates that early initiation can be safely achieved and can improve patient outcomes.
Adaptive Control Using Neural Network Augmentation for a Modified F-15 Aircraft
NASA Technical Reports Server (NTRS)
Burken, John J.; Williams-Hayes, Peggy; Karneshige, J. T.; Stachowiak, Susan J.
2006-01-01
Description of the performance of a simplified dynamic inversion controller with neural network augmentation follows. Simulation studies focus on the results with and without neural network adaptation through the use of an F-15 aircraft simulator that has been modified to include canards. Simulated control law performance with a surface failure, in addition to an aerodynamic failure, is presented. The aircraft, with adaptation, attempts to minimize the inertial cross-coupling effect of the failure (a control derivative anomaly associated with a jammed control surface). The dynamic inversion controller calculates necessary surface commands to achieve desired rates. The dynamic inversion controller uses approximate short period and roll axis dynamics. The yaw axis controller is a sideslip rate command system. Methods are described to reduce the cross-coupling effect and maintain adequate tracking errors for control surface failures. The aerodynamic failure destabilizes the pitching moment due to angle of attack. The results show that control of the aircraft with the neural networks is easier (more damped) than without the neural networks. Simulation results show neural network augmentation of the controller improves performance with aerodynamic and control surface failures in terms of tracking error and cross-coupling reduction.
Failure mechanism of shear-wall dominant multi-story buildings
Yuksel, S.B.; Kalkan, E.
2008-01-01
The recent trend in the building industry of Turkey as well as in many European countries is towards utilizing the tunnel form (shear-wall dominant) construction system for development of multi-story residential units. The tunnel form buildings diverge from other conventional reinforced concrete (RC) buildings due to the lack of beams and columns in their structural integrity. The vertical load-carrying members of these buildings are the structural-walls only, and the floor system is a flat plate. Besides the constructive advantages, tunnel form buildings provide superior seismic performance compared to conventional RC frame and dual systems as observed during the recent devastating earthquakes in Turkey (1999 Mw 7.4 Kocaeli, Mw 7.2 Duzce, and 2004 Mw 6.5 Bingol). With its proven earthquake performance, the tunnel form system is becoming the primary construction technique in many seismically active regions. In this study, a series of nonlinear analyses were conducted using finite element (FE) models to augment our understanding on their failure mechanism under lateral forces. In order to represent the nonlinear behavior adequately, The FE models were verified with the results of experimental studies performed on three dimensional (3D) scaled tunnel form building specimens. The results of this study indicate that the structural walls of tunnel form buildings may exhibit brittle flexural failure under lateral loading, if they are not properly reinforced. The global tension/compression couple triggers this failure mechanism by creating pure axial tension in the outermost shear-walls.
Quasi-static analysis of elastic behavior for some systems having higher fracture densities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berryman, J.G.; Aydin, A.
2009-10-15
Elastic behavior of geomechanical systems with interacting (but not intersecting) fractures is treated using generalizations of the Backus and the Schoenberg-Muir methods for analyzing layered systems whose layers are intrinsically anisotropic due to locally aligned fractures. By permitting the axis of symmetry of the locally anisotropic compliance matrix for individual layers to differ from that of the layering direction, we derive analytical formulas for interacting fractured regions with arbitrary orientations to each other. This procedure provides a systematic tool for studying how contiguous, but not yet intersecting, fractured domains interact, and provides a direct (though approximate) means of predicting whenmore » and how such interactions lead to more dramatic weakening effects and ultimately to failure of these complicated systems. The method permits decomposition of the system elastic behavior into specific eigenmodes that can all be analyzed, and provides a better understanding about which of these specific modes are expected to be most important to the evolving failure process.« less
A Remote Patient Monitoring System for Congestive Heart Failure
Suh, Myung-kyung; Chen, Chien-An; Woodbridge, Jonathan; Tu, Michael Kai; Kim, Jung In; Nahapetian, Ani; Evangelista, Lorraine S.; Sarrafzadeh, Majid
2011-01-01
Congestive heart failure (CHF) is a leading cause of death in the United States affecting approximately 670,000 individuals. Due to the prevalence of CHF related issues, it is prudent to seek out methodologies that would facilitate the prevention, monitoring, and treatment of heart disease on a daily basis. This paper describes WANDA (Weight and Activity with Blood Pressure Monitoring System); a study that leverages sensor technologies and wireless communications to monitor the health related measurements of patients with CHF. The WANDA system is a three-tier architecture consisting of sensors, web servers, and back-end databases. The system was developed in conjunction with the UCLA School of Nursing and the UCLA Wireless Health Institute to enable early detection of key clinical symptoms indicative of CHF-related decompensation. This study shows that CHF patients monitored by WANDA are less likely to have readings fall outside a healthy range. In addition, WANDA provides a useful feedback system for regulating readings of CHF patients. PMID:21611788
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkinson, V.K.; Young, J.M.
1995-07-01
The US Army`s Project Manager, Advanced Field Artillery System/Future Armored Resupply Vehicle (PM-AFAS/FARV) is sponsoring the development of technologies that can be applied to the resupply vehicle for the Advanced Field Artillery System. The Engineering Technology Division of the Oak Ridge National Laboratory has proposed adding diagnostics/prognostics systems to four components of the Ammunition Transfer Arm of this vehicle, and a cost-benefit analysis was performed on the diagnostics/prognostics to show the potential savings that may be gained by incorporating these systems onto the vehicle. Possible savings could be in the form of reduced downtime, less unexpected or unnecessary maintenance, fewermore » regular maintenance checks. and/or tower collateral damage or loss. The diagnostics/prognostics systems are used to (1) help determine component problems, (2) determine the condition of the components, and (3) estimate the remaining life of the monitored components. The four components on the arm that are targeted for diagnostics/prognostics are (1) the electromechanical brakes, (2) the linear actuators, (3) the wheel/roller bearings, and (4) the conveyor drive system. These would be monitored using electrical signature analysis, vibration analysis, or a combination of both. Annual failure rates for the four components were obtained along with specifications for vehicle costs, crews, number of missions, etc. Accident scenarios based on component failures were postulated, and event trees for these scenarios were constructed to estimate the annual loss of the resupply vehicle, crew, arm. or mission aborts. A levelized cost-benefit analysis was then performed to examine the costs of such failures, both with and without some level of failure reduction due to the diagnostics/prognostics systems. Any savings resulting from using diagnostics/prognostics were calculated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mouton, S.; Ledoux, Y.; Teissandier, D.
A key challenge for the future is to reduce drastically the human impact on the environment. In the aeronautic field, this challenge aims at optimizing the design of the aircraft to decrease the global mass. This reduction leads to the optimization of every part constitutive of the plane. This operation is even more delicate when the used material is composite material. In this case, it is necessary to find a compromise between the strength, the mass and the manufacturing cost of the component. Due to these different kinds of design constraints it is necessary to assist engineer with decision supportmore » system to determine feasible solutions. In this paper, an approach is proposed based on the coupling of the different key characteristics of the design process and on the consideration of the failure risk of the component. The originality of this work is that the manufacturing deviations due to the RTM process are integrated in the simulation of the assembly process. Two kinds of deviations are identified: volume impregnation (injection phase of RTM process) and geometrical deviations (curing and cooling phases). The quantification of these deviations and the related failure risk calculation is based on finite element simulations (Pam RTM registered and Samcef registered softwares). The use of genetic algorithm allows to estimate the impact of the design choices and their consequences on the failure risk of the component. The main focus of the paper is the optimization of tool design. In the framework of decision support systems, the failure risk calculation is used for making the comparison of possible industrialization alternatives. It is proposed to apply this method on a particular part of the airplane structure: a spar unit made of carbon fiber/epoxy composite.« less
NASA Astrophysics Data System (ADS)
Yang, Zhenyin
Metal-contact MEMS switches hold great promise for implementing agile radio frequency (RF) systems because of their small size, low fabrication cost, low power consumption, wide operational band, excellent isolation and exceptionally low signal insertion loss. Gold is often utilized as a contact material for metal-contact MEMS switches due to its excellent electrical conductivity and corrosion resistance. However contact wear and stiction are the two major failure modes for these switches due to its material softness and high surface adhesion energy. To strengthen the contact material, pure gold was alloyed with other metal elements. We designed and constructed a new micro-contacting test facility that closely mimic the typical MEMS operation and utilized this facility to efficiently evaluate optimized contact materials. Au-Ni binary alloy system as the candidate contact material for MEMS switches was systematically investigated. A correlation between contact material properties (etc. microstructure, micro-hardness, electrical resistivity, topology, surface structures and composition) and micro-contacting performance was established. It was demonstrated nano-scale graded two-phase Au-Ni film could possibly yield an improved device performance. Gold micro-contact degradation mechanisms were also systematically investigated by running the MEMS switching tests under a wide range of test conditions. According to our quantitative failure analysis, field evaporation could be the dominant failure mode for highfield (> critical threshold field) hot switching; transient thermal-assisted wear could be the dominant failure mode for low-field hot switching; on the other hand, pure mechanical wear and steady current heating (1 mA) caused much less contact degradation in cold switching tests. Results from low-force (50 muN/micro-contact), low current (0.1 mA) tests on real MEMS switches indicated that continuous adsorbed films from ambient air could degrade the switch contact resistance. Our work also contributes to the field of general nano-science and technology by resolving the transfer directionality of field evaporation of gold in atomic force microscope (AFM)/scanning tunneling microscope (STM).
NASA Technical Reports Server (NTRS)
Lewicki, David George; Lambert, Nicholas A.; Wagoner, Robert S.
2015-01-01
The diagnostics capability of micro-electro-mechanical systems (MEMS) based rotating accelerometer sensors in detecting gear tooth crack failures in helicopter main-rotor transmissions was evaluated. MEMS sensors were installed on a pre-notched OH-58C spiral-bevel pinion gear. Endurance tests were performed and the gear was run to tooth fracture failure. Results from the MEMS sensor were compared to conventional accelerometers mounted on the transmission housing. Most of the four stationary accelerometers mounted on the gear box housing and most of the CI's used gave indications of failure at the end of the test. The MEMS system performed well and lasted the entire test. All MEMS accelerometers gave an indication of failure at the end of the test. The MEMS systems performed as well, if not better, than the stationary accelerometers mounted on the gear box housing with regards to gear tooth fault detection. For both the MEMS sensors and stationary sensors, the fault detection time was not much sooner than the actual tooth fracture time. The MEMS sensor spectrum data showed large first order shaft frequency sidebands due to the measurement rotating frame of reference. The method of constructing a pseudo tach signal from periodic characteristics of the vibration data was successful in deriving a TSA signal without an actual tach and proved as an effective way to improve fault detection for the MEMS.
van Walraven, Carl
2017-04-01
Diagnostic codes used in administrative databases cause bias due to misclassification of patient disease status. It is unclear which methods minimize this bias. Serum creatinine measures were used to determine severe renal failure status in 50,074 hospitalized patients. The true prevalence of severe renal failure and its association with covariates were measured. These were compared to results for which renal failure status was determined using surrogate measures including the following: (1) diagnostic codes; (2) categorization of probability estimates of renal failure determined from a previously validated model; or (3) bootstrap methods imputation of disease status using model-derived probability estimates. Bias in estimates of severe renal failure prevalence and its association with covariates were minimal when bootstrap methods were used to impute renal failure status from model-based probability estimates. In contrast, biases were extensive when renal failure status was determined using codes or methods in which model-based condition probability was categorized. Bias due to misclassification from inaccurate diagnostic codes can be minimized using bootstrap methods to impute condition status using multivariable model-derived probability estimates. Copyright © 2017 Elsevier Inc. All rights reserved.
Large Crater Repair at Silver Flag Exercise Site, Tyndall Air Force Base, Florida
2015-08-01
fiberglass mat ( FFM ) survived medium-speed braking events and was deemed suitable for use on taxiways and aprons. 2. The current USAF FFM system failed...braking events due to failure of the connector bushings. After replacement with more robust connector bushings from the FFM system, the FRP system...withstood the high-speed taxi events that caused the FFM to fail. ERDC/GSL TR-15-27 2 4. AM2 aluminum matting was successfully tested as a suitable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christie, R.F.; Stetkar, J.W.
1985-01-01
The change in availability of the high-pressure coolant injection system (HPCIS) due to a change in pump and valve test interval from monthly to quarterly was analyzed. This analysis started by using the HPCIS base line evaluation produced as part of the Browns Ferry Nuclear Plant (BFN) Probabilistic Risk Assessment (PRA). The base line evaluation showed that the dominant contributors to the unavailability of the HPCI system are hardware failures and the resultant downtime for unscheduled maintenance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roach, Dennis Patrick; Jauregui, David Villegas; Daumueller, Andrew Nicholas
2012-02-01
Recent structural failures such as the I-35W Mississippi River Bridge in Minnesota have underscored the urgent need for improved methods and procedures for evaluating our aging transportation infrastructure. This research seeks to develop a basis for a Structural Health Monitoring (SHM) system to provide quantitative information related to the structural integrity of metallic structures to make appropriate management decisions and ensuring public safety. This research employs advanced structural analysis and nondestructive testing (NDT) methods for an accurate fatigue analysis. Metal railroad bridges in New Mexico will be the focus since many of these structures are over 100 years old andmore » classified as fracture-critical. The term fracture-critical indicates that failure of a single component may result in complete collapse of the structure such as the one experienced by the I-35W Bridge. Failure may originate from sources such as loss of section due to corrosion or cracking caused by fatigue loading. Because standard inspection practice is primarily visual, these types of defects can go undetected due to oversight, lack of access to critical areas, or, in riveted members, hidden defects that are beneath fasteners or connection angles. Another issue is that it is difficult to determine the fatigue damage that a structure has experienced and the rate at which damage is accumulating due to uncertain history and load distribution in supporting members. A SHM system has several advantages that can overcome these limitations. SHM allows critical areas of the structure to be monitored more quantitatively under actual loading. The research needed to apply SHM to metallic structures was performed and a case study was carried out to show the potential of SHM-driven fatigue evaluation to assess the condition of critical transportation infrastructure and to guide inspectors to potential problem areas. This project combines the expertise in transportation infrastructure at New Mexico State University with the expertise at Sandia National Laboratories in the emerging field of SHM.« less
An Accident Precursor Analysis Process Tailored for NASA Space Systems
NASA Technical Reports Server (NTRS)
Groen, Frank; Stamatelatos, Michael; Dezfuli, Homayoon; Maggio, Gaspare
2010-01-01
Accident Precursor Analysis (APA) serves as the bridge between existing risk modeling activities, which are often based on historical or generic failure statistics, and system anomalies, which provide crucial information about the failure mechanisms that are actually operative in the system and which may differ in frequency or type from those in the various models. These discrepancies between the models (perceived risk) and the system (actual risk) provide the leading indication of an underappreciated risk. This paper presents an APA process developed specifically for NASA Earth-to-Orbit space systems. The purpose of the process is to identify and characterize potential sources of system risk as evidenced by anomalous events which, although not necessarily presenting an immediate safety impact, may indicate that an unknown or insufficiently understood risk-significant condition exists in the system. Such anomalous events are considered accident precursors because they signal the potential for severe consequences that may occur in the future, due to causes that are discernible from their occurrence today. Their early identification allows them to be integrated into the overall system risk model used to intbrm decisions relating to safety.
Static stability of a three-dimensional space truss. M.S. Thesis - Case Western Reserve Univ., 1994
NASA Technical Reports Server (NTRS)
Shaker, John F.
1995-01-01
In order to deploy large flexible space structures it is necessary to develop support systems that are strong and lightweight. The most recent example of this aerospace design need is vividly evident in the space station solar array assembly. In order to accommodate both weight limitations and strength performance criteria, ABLE Engineering has developed the Folding Articulating Square Truss (FASTMast) support structure. The FASTMast is a space truss/mechanism hybrid that can provide system support while adhering to stringent packaging demands. However, due to its slender nature and anticipated loading, stability characterization is a critical part of the design process. Furthermore, the dire consequences surely to result from a catastrophic instability quickly provide the motivation for careful examination of this problem. The fundamental components of the space station solar array system are the (1) solar array blanket system, (2) FASTMast support structure, and (3) mast canister assembly. The FASTMast once fully deployed from the canister will provide support to the solar array blankets. A unique feature of this structure is that the system responds linearly within a certain range of operating loads and nonlinearly when that range is exceeded. The source of nonlinear behavior in this case is due to a changing stiffness state resulting from an inability of diagonal members to resist applied loads. The principal objective of this study was to establish the failure modes involving instability of the FASTMast structure. Also of great interest during this effort was to establish a reliable analytical approach capable of effectively predicting critical values at which the mast becomes unstable. Due to the dual nature of structural response inherent to this problem, both linear and nonlinear analyses are required to characterize the mast in terms of stability. The approach employed herein is one that can be considered systematic in nature. The analysis begins with one and two-dimensional failure models of the system and its important components. From knowledge gained through preliminary analyses a foundation is developed for three-dimensional analyses of the FASTMast structure. The three-dimensional finite element (FE) analysis presented here involves a FASTMast system one-tenth the size of the actual flight unit. Although this study does not yield failure analysis results that apply directly to the flight article, it does establish a method by which the full-scale mast can be evaluated.
Static stability of a three-dimensional space truss
NASA Astrophysics Data System (ADS)
Shaker, John F.
1995-05-01
In order to deploy large flexible space structures it is necessary to develop support systems that are strong and lightweight. The most recent example of this aerospace design need is vividly evident in the space station solar array assembly. In order to accommodate both weight limitations and strength performance criteria, ABLE Engineering has developed the Folding Articulating Square Truss (FASTMast) support structure. The FASTMast is a space truss/mechanism hybrid that can provide system support while adhering to stringent packaging demands. However, due to its slender nature and anticipated loading, stability characterization is a critical part of the design process. Furthermore, the dire consequences surely to result from a catastrophic instability quickly provide the motivation for careful examination of this problem. The fundamental components of the space station solar array system are the (1) solar array blanket system, (2) FASTMast support structure, and (3) mast canister assembly. The FASTMast once fully deployed from the canister will provide support to the solar array blankets. A unique feature of this structure is that the system responds linearly within a certain range of operating loads and nonlinearly when that range is exceeded. The source of nonlinear behavior in this case is due to a changing stiffness state resulting from an inability of diagonal members to resist applied loads. The principal objective of this study was to establish the failure modes involving instability of the FASTMast structure. Also of great interest during this effort was to establish a reliable analytical approach capable of effectively predicting critical values at which the mast becomes unstable. Due to the dual nature of structural response inherent to this problem, both linear and nonlinear analyses are required to characterize the mast in terms of stability. The approach employed herein is one that can be considered systematic in nature. The analysis begins with one and two-dimensional failure models of the system and its important components. From knowledge gained through preliminary analyses a foundation is developed for three-dimensional analyses of the FASTMast structure. The three-dimensional finite element (FE) analysis presented here involves a FASTMast system one-tenth the size of the actual flight unit. Although this study does not yield failure analysis results that apply directly to the flight article, it does establish a method by which the full-scale mast can be evaluated.
Chen, Kuan-Jung; Chen, Tso-Hsiao; Sue, Yuh-Mou; Chen, Tzay-Jinn; Cheng, Chung-Yi
2014-10-01
Heat stroke is a life-threatening condition characterized by an increased core body temperature (over 40°C) and a systemic inflammatory response, which may lead to a syndrome of multiple organ dysfunction. Heat stroke may be due to either strenuous exercise or non-exercise-induced exposure to a high environmental temperature. Current management of heat stroke is mostly supportive, with an emphasis on cooling the core body temperature and preventing the development of multiple organ dysfunction. Prognosis of heat stroke depends on the severity of organ involvement. Here, we report a rare case of non-exercise-induced heat stroke in a 73-year-old male patient who was suffering from acute liver failure after prolonged exposure in a hot sauna room. We successfully managed this patient by administering high-volume plasma exchange, and the patient recovered completely after treatment. © 2014 Wiley Periodicals, Inc.
Submarine slope failures due to pipe structure formation.
Elger, Judith; Berndt, Christian; Rüpke, Lars; Krastel, Sebastian; Gross, Felix; Geissler, Wolfram H
2018-02-19
There is a strong spatial correlation between submarine slope failures and the occurrence of gas hydrates. This has been attributed to the dynamic nature of gas hydrate systems and the potential reduction of slope stability due to bottom water warming or sea level drop. However, 30 years of research into this process found no solid supporting evidence. Here we present new reflection seismic data from the Arctic Ocean and numerical modelling results supporting a different link between hydrates and slope stability. Hydrates reduce sediment permeability and cause build-up of overpressure at the base of the gas hydrate stability zone. Resulting hydro-fracturing forms pipe structures as pathways for overpressured fluids to migrate upward. Where these pipe structures reach shallow permeable beds, this overpressure transfers laterally and destabilises the slope. This process reconciles the spatial correlation of submarine landslides and gas hydrate, and it is independent of environmental change and water depth.
The Total Artificial Heart in End-Stage Congenital Heart Disease.
Villa, Chet R; Morales, David L S
2017-01-01
The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD.
The Total Artificial Heart in End-Stage Congenital Heart Disease
Villa, Chet R.; Morales, David L. S.
2017-01-01
The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD. PMID:28536530
Identification of priorities for medication safety in neonatal intensive care.
Kunac, Desireé L; Reith, David M
2005-01-01
Although neonates are reported to be at greater risk of medication error than infants and older children, little is known about the causes and characteristics of error in this patient group. Failure mode and effects analysis (FMEA) is a technique used in industry to evaluate system safety and identify potential hazards in advance. The aim of this study was to identify and prioritize potential failures in the neonatal intensive care unit (NICU) medication use process through application of FMEA. Using the FMEA framework and a systems-based approach, an eight-member multidisciplinary panel worked as a team to create a flow diagram of the neonatal unit medication use process. Then by brainstorming, the panel identified all potential failures, their causes and their effects at each step in the process. Each panel member independently rated failures based on occurrence, severity and likelihood of detection to allow calculation of a risk priority score (RPS). The panel identified 72 failures, with 193 associated causes and effects. Vulnerabilities were found to be distributed across the entire process, but multiple failures and associated causes were possible when prescribing the medication and when preparing the drug for administration. The top ranking issue was a perceived lack of awareness of medication safety issues (RPS score 273), due to a lack of medication safety training. The next highest ranking issues were found to occur at the administration stage. Common potential failures related to errors in the dose, timing of administration, infusion pump settings and route of administration. Perceived causes were multiple, but were largely associated with unsafe systems for medication preparation and storage in the unit, variable staff skill level and lack of computerised technology. Interventions to decrease medication-related adverse events in the NICU should aim to increase staff awareness of medication safety issues and focus on medication administration processes.
Neonatal circulatory failure due to acute hypertensive crisis: clinical and echocardiographic clues.
Louw, Jacoba; Brown, Stephen; Thewissen, Liesbeth; Smits, Anne; Eyskens, Benedicte; Heying, Ruth; Cools, Bjorn; Levtchenko, Elena; Allegaert, Karel; Gewillig, Marc
2013-04-01
Circulatory failure due to acute arterial hypertension in the neonatal period is rare. This study was undertaken to assess the clinical and echocardiographic manifestations of circulatory failure resulting from acute neonatal hypertensive crisis. Neonatal and cardiology databases from 2007 to 2010 were reviewed. An established diagnosis of circulatory failure due to neonatal hypertension before the age of 14 days was required for inclusion. Six patients were identified. Five patients presented with circulatory failure due to an acute hypertensive crisis. The median age at presentation was 8.5 days (range: 6.0-11.0) with a median body weight of 3.58 kg (range: 0.86-4.70). Echocardiography demonstrated mild left ventricular dysfunction [median shortening fraction (SF) 25%, range 10-30] and mild aortic regurgitation in 83% (5/6) of patients. One patient with left ventricular dysfunction (SF = 17%) had a large apical thrombus. Two patients were hypotensive, and hypertension only became evident after restoration of cardiac output. Administration of intravenous milrinone was successful, with rapid improvement of the clinical condition. Left ventricular function normalised in all survivors. Early neonatal circulatory collapse due to arterial hypertension is a rare but potentially life-threatening condition. At presentation, hypotension, especially in the presence of a dysfunctional left ventricle, does not exclude a hypertensive crisis being the cause of circulatory failure. The echocardiographic presence of mild aortic regurgitation combined with left ventricular hypocontractility in a structurally normal heart should alert the physician to the presence of underlying hypertension.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Lingley, Zachary; Ayvazian, Talin; Brodie, Miles; Ives, Neil
2018-02-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to COD, it is especially crucial for space satellite applications to investigate reliability, failure modes, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we report root causes investigation of COBD by performing long-term lifetests followed by failure mode analysis (FMA) using various micro-analytical techniques including electron beam induced current (EBIC), time-resolved electroluminescence (EL), focused ion beam (FIB), high-resolution transmission electron microscopy (TEM), and deep level transient spectroscopy (DLTS). Our life-tests with accumulated test hours of over 25,000 hours for SM lasers and over 35,000 hours for MM lasers generated a number of COBD failures with various failure times. EBIC techniques were employed to study dark line defects (DLDs) generated in SM COBD failures stressed under different test conditions. FIB and high-resolution TEM were employed to prepare cross sectional and plan view TEM specimens to study DLD areas (dislocations) in post-aged SM lasers. Time-resolved EL techniques were employed to study initiation and progressions of dark spots and dark lines in real time as MM lasers were aged. Lastly, to investigate precursor signatures of failure and degradation mechanisms responsible for COBD in both SM and MM lasers, we employed DLTS techniques to study a role that electron traps (non-radiative recombination centers) play in degradation of these lasers. Our in-depth root causes investigation results are reported.
Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto
2018-06-14
Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.
Posterior Open Bite Due to Failure of Maxillary Molar Eruption.
Yasumura, Toshihiko; Sueishi, Kenji
2016-01-01
Posterior open bite can cause problems with occlusion. It arises from systemic or local factors such as physical or functional interference, ankylosis, and failure of eruption. Primary failure of eruption (PFE) is a rare condition that is difficult to differentiate from ankylosis and requires complex treatment strategies. Here we report a 12-year-old girl who was referred to our hospital by her dentist for re-evaluation of eruption failure of the left maxillary secondary premolar and first and second molars with congenitally missing maxillary lateral teeth. The maxillary first molar was extracted for a therapeutic diagnosis. The left maxillary secondary premolar and second molar reacted well to subsequent orthodontic treatment. Auto-transplantation of the mandibular premolar to the maxil-lary arch was carried out to achieve optimal overjet, overbite, and occlusion. The active treatment period spanned 4 years and 1 month. Assessment of the patient's medical and dental history, prior trauma, and clinical conditions resulted in a therapeutic diagnosis of PFE. Satisfactory orthodontic treatment results were achieved.
George, Susan; Leasure, A Renee
2016-01-01
Heart failure (HF) is a major health problem in United States, and it has reached epidemic proportions. Heart failure is associated with significant morbidity, mortality, and cost. Although the prognosis of HF is worse than many forms of cancer, many patients, families, and clinicians are unaware of the dire prognosis. As the disease progress to advanced HF, patients are faced with many challenges, such as poor quality of life due to worsening symptoms and frequent hospitalizations. Heart failure management adds significant financial burden to the health care system. Palliative care can be integrated into HF care to improve quality of life and symptom management and to address physical, spiritual, and psychosocial needs of patients and families. Palliative care can be used concurrently with or independent of curative or life-prolonging HF therapies. Transformational leadership principles were used to guide the development of a plan to enhance integration of palliative care within traditional advanced HF care.
NASA Technical Reports Server (NTRS)
Sisson, R. D., Jr.; Sone, Ichiro; Biederman, R. R.
1985-01-01
Partially Stabilized Zirconia (PSZ) may become widely used for Thermal Barrier Coatings (TBC). Failure of these coatings can occur due to thermal fatigue in oxidizing atmospheres. The failure is due to the strains that develop due to thermal gradients, differences in thermal expansion coefficients, and oxidation of the bond coating. The role of microstructure and the cubic, tetragonal, and monoclinic phase distribution in the strain development and subsequent failure will be discussed. An X-ray diffraction technique for accurate determination of the fraction of each phase in PSZ will be applied to understanding the phase transformations and strain development. These results will be discussed in terms of developing a model for life prediction in PSZ coatings during thermal cycling.
A fuzzy logic intelligent diagnostic system for spacecraft integrated vehicle health management
NASA Technical Reports Server (NTRS)
Wu, G. Gordon
1995-01-01
Due to the complexity of future space missions and the large amount of data involved, greater autonomy in data processing is demanded for mission operations, training, and vehicle health management. In this paper, we develop a fuzzy logic intelligent diagnostic system to perform data reduction, data analysis, and fault diagnosis for spacecraft vehicle health management applications. The diagnostic system contains a data filter and an inference engine. The data filter is designed to intelligently select only the necessary data for analysis, while the inference engine is designed for failure detection, warning, and decision on corrective actions using fuzzy logic synthesis. Due to its adaptive nature and on-line learning ability, the diagnostic system is capable of dealing with environmental noise, uncertainties, conflict information, and sensor faults.
Roles of Shape and Internal Structure in Rotational Disruption of Asteroids
NASA Astrophysics Data System (ADS)
Hirabayashi, Masatoshi; Scheeres, Daniel Jay
2015-08-01
An active research area over the last decade has been to explore configuration changes of rubble pile asteroids due to rotationally induced disruption, initially driven by the remarkable fact that there is a spin period threshold of 2 hr for asteroids larger than a few hundred meters in size. Several different disruption modes due to rapid rotation can be identified, as surface shedding, fission and failure of the internal structure. Relevant to these discussions are many observations of asteroid shapes that have revealed a diversity of forms such as oblate spheroids with equatorial ridges, strongly elongated shapes and contact binaries, to say nothing of multi-body systems. With consideration that rotationally induced deformation is one of the primary drivers of asteroid evolution, we have been developing two techniques for investigating the structure of asteroids, while accounting for their internal mechanical properties through plastic theory. The first technique developed is an analytical model based on limit analysis, which provides rigorous bounds on the asteroid mechanical properties for their shapes to remain stable. The second technique applies finite element model analysis that accounts for plastic deformation. Combining these models, we have explored the correlation between unique shape features and failure modes. First, we have been able to show that contact binary asteroids preferentially fail at their narrow necks at a relatively slow spin period, due to stress concentration. Second, applying these techniques to the breakup event of active asteroid P/2013 R3, we have been able to develop explicit constraints on the cohesion within rubble pile asteroids. Third, by probing the effect of inhomogeneous material properties, we have been able to develop conditions for whether an oblate body will fail internally or through surface shedding. These different failure modes can be tested by measuring the density distribution within a rubble pile body through determination of its gravity field. This talk will explore these different modes of failure and motivate divergent theories of failure that depend on properties of rubble piles.
Fatigue evaluation of socket welded piping in nuclear power plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vecchio, R.S.
1996-12-01
Fatigue failures in piping systems occur, almost without exception, at the welded connections. In nuclear power plant systems, such failures occur predominantly at the socket welds of small diameter piping ad fillet attachment welds under high-cycle vibratory conditions. Nearly all socket weld fatigue failures are identified by leaks which, though not high in volume, generally are costly due to attendant radiological contamination. Such fatigue cracking was recently identified in the 3/4 in. diameter recirculation and relief piping socket welds from the reactor coolant system (RCS) charging pumps at a nuclear power plant. Consequently, a fatigue evaluation was performed to determinemore » the cause of cracking and provide an acceptable repair. Socket weld fatigue life was evaluated using S-N type fatigue life curves for welded structures developed by AASHTO and the assessment of an effective cyclic stress range adjacent to each socket weld. Based on the calculated effective tress ranges and assignment of the socket weld details to the appropriate AASHTO S-N curves, the socket weld fatigue lives were calculated and found to be in excellent agreement with the accumulated cyclic life to-date.« less
A Predictive Framework to Elucidate Venous Stenosis: CFD & Shape Optimization.
Javid Mahmoudzadeh Akherat, S M; Cassel, Kevin; Boghosian, Michael; Hammes, Mary; Coe, Fredric
2017-07-01
The surgical creation of vascular accesses for renal failure patients provides an abnormally high flow rate conduit in the patient's upper arm vasculature that facilitates the hemodialysis treatment. These vascular accesses, however, are very often associated with complications that lead to access failure and thrombotic incidents, mainly due to excessive neointimal hyperplasia (NH) and subsequently stenosis. Development of a framework to monitor and predict the evolution of the venous system post access creation can greatly contribute to maintaining access patency. Computational fluid dynamics (CFD) has been exploited to inspect the non-homeostatic wall shear stress (WSS) distribution that is speculated to trigger NH in the patient cohort under investigation. Thereafter, CFD in liaison with a gradient-free shape optimization method has been employed to analyze the deformation modes of the venous system enduring non-physiological hemodynamics. It is observed that the optimally evolved shapes and their corresponding hemodynamics strive to restore the homeostatic state of the venous system to a normal, pre-surgery condition. It is concluded that a CFD-shape optimization coupling that seeks to regulate the WSS back to a well-defined physiological WSS target range can accurately predict the mode of patient-specific access failure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mossahebi, S; Feigenberg, S; Nichols, E
Purpose: GammaPod™, the first stereotactic radiotherapy device for early stage breast cancer treatment, has been recently installed and commissioned at our institution. A multidisciplinary working group applied the failure mode and effects analysis (FMEA) approach to perform a risk analysis. Methods: FMEA was applied to the GammaPod™ treatment process by: 1) generating process maps for each stage of treatment; 2) identifying potential failure modes and outlining their causes and effects; 3) scoring the potential failure modes using the risk priority number (RPN) system based on the product of severity, frequency of occurrence, and detectability (ranging 1–10). An RPN of highermore » than 150 was set as the threshold for minimal concern of risk. For these high-risk failure modes, potential quality assurance procedures and risk control techniques have been proposed. A new set of severity, occurrence, and detectability values were re-assessed in presence of the suggested mitigation strategies. Results: In the single-day image-and-treat workflow, 19, 22, and 27 sub-processes were identified for the stages of simulation, treatment planning, and delivery processes, respectively. During the simulation stage, 38 potential failure modes were found and scored, in terms of RPN, in the range of 9-392. 34 potential failure modes were analyzed in treatment planning with a score range of 16-200. For the treatment delivery stage, 47 potential failure modes were found with an RPN score range of 16-392. The most critical failure modes consisted of breast-cup pressure loss and incorrect target localization due to patient upper-body alignment inaccuracies. The final RPN score of these failure modes based on recommended actions were assessed to be below 150. Conclusion: FMEA risk analysis technique was applied to the treatment process of GammaPod™, a new stereotactic radiotherapy technology. Application of systematic risk analysis methods is projected to lead to improved quality of GammaPod™ treatments. Ying Niu and Cedric Yu are affiliated with Xcision Medical Systems.« less
Kato, Taiki; Hamano, Atsushi; Kawamura, Hideki
2014-10-01
We report a 35 month-old boy with acute renal failure caused by an obstructive ureteral stone associated with norovirus gastroenteritis. He visited his family physician because of fever, abdominal pain and vomiting. He was diagnosed as acute gastroenteritis. The symptoms relieved once, but abdominal pain and vomiting recurred two days after the visit and the volume of urine decreased. He was diagnosed as norovirus gastoenteritis and acute renal failure which was unresponsive to fluid replacement. Ultrasound study of the abdomen showed a solitary kidney with mild hydronephrosis. He was then admitted to our hospital. He was finally diagnosed as acute postrenal failure due to obstructive ureteral stone with left solitary kidney by abdominal computer tomography (CT). We performed transurethral catheterization immediately. The creatinine and blood urea nitrogen returned to normal level in 2 days. The CT performed on the 28th day post operation showed disappearance of the stone after uric alkalization. Recently, some cases of postrenal failure due to bilateral obstructive ureteral stones, mainly ammonium acid urate stones, associated with viral gastroenteritis were reported. As clinical features, they are common in boys three years or younger after an episode of rotavirus gastroenteritis with high uric acid concentration. By far, the most common cause of acute renal failure in patients with severe gastroenteritis is prerenal failure resulting from hypovolemia. But postrenal cause due to bilateral obstructive stones should be taken in a consideration.
Computational hydraulics of a cascade of experimental-scale landside dam failures
NASA Astrophysics Data System (ADS)
Wright, N.; Guan, M.
2015-12-01
Abstract: Landslide dams typically comprise unconsolidated and poorly sorted material, and are vulnerable to rapid failure and breaching, particularly in mountainous areas during high intense rainfalls. A large flash flood with high-concentrated sediment can be formed in a short period, and the magnitude is likely to be amplified along the flow direction due to the inclusion of a large amount of sediment. This can result in significant and sudden flood risk downstream for human life and property. Numerous field evidence has indicated the various risks of landslide dam failures. In general, cascading landslide dams can be formed along the sloping channel due to the randomness and unpredictability of landslides, which complexes the hydraulics of landslide dam failures. The failure process of a single dam and subsequent floods has attracted attention in multidisciplinary studies. However, the dynamic failure process of cascading landslide dams has been poorly understood. From a viewpoint of simulation, this study evaluates the formation and development of rapid sediment-charged floods due to cascading failure of landslide dams through detailed hydro-morphodynamic modelling. The model used is based on shallow water theory and it has been successful in predicting the flow and morphological process during sudden dam-break, as well as full and partial dyke-breach. Various experimental-scale scenarios are modelled, including: (1) failure of a single full dam in a sloping channel, (2) failure of two dams in a sloping channel, (3) failure of multiple landslide dams (four) in a sloping channel. For each scenario, different failure modes (sudden/gradual) and bed boundary (fixed /mobile) are assumed and simulated. The study systematically explores the tempo-spatial evolution of landslide-induced floods (discharge, flow velocity, and flow concentration) and geomorphic properties along the sloping channel. The effects of in-channel erosion and flow-driven sediment from dams on the development of flood process are investigated. The results improve the understanding of the formation and development mechanism of flash floods due to cascading landslide dam failures. The findings are beneficial for downstream flood risk assessment and developing control strategies for landslide-induced floods.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
A huge bladder calculus causing acute renal failure.
Komeya, Mitsuru; Sahoda, Tamami; Sugiura, Shinpei; Sawada, Takuto; Kitami, Kazuo
2013-02-01
A 81-year-old male was referred to our emergency outpatient unit due to acute renal failure. The level of serum creatinine was 276 μmol/l. A CT scan showed bilateral hydronephroureter, large bladder stone (7 cm × 6 cm × 6 cm) and bladder wall thickness. He was diagnosed as post renal failure due to bilateral hydronephroureter. Large bladder stone is thought to be the cause of bilateral hydronephroureter and renal failure. To improve renal failure, we performed open cystolithotomy and urethral catheterization. Three days after the surgery, the level of serum creatinine decreased to 224 μmol/l. He was discharged from our hospital with uneventful course. Bladder calculus is thought to be a rare cause of renal failure. We summarize the characteristics of bladder calculus causing renal failure. We should keep that long-term pyuria and urinary symptom, and repeated urinary tract infection can cause huge bladder calculus and renal failure in mind.
Kotooka, Norihiko; Kitakaze, Masafumi; Nagashima, Kengo; Asaka, Machiko; Kinugasa, Yoshiharu; Nochioka, Kotaro; Mizuno, Atsushi; Nagatomo, Daisuke; Mine, Daigo; Yamada, Yoko; Kuratomi, Akiko; Okada, Norihiro; Fujimatsu, Daisuke; Kuwahata, So; Toyoda, Shigeru; Hirotani, Shin-Ichi; Komori, Takahiro; Eguchi, Kazuo; Kario, Kazuomi; Inomata, Takayuki; Sugi, Kaoru; Yamamoto, Kazuhiro; Tsutsui, Hiroyuki; Masuyama, Tohru; Shimokawa, Hiroaki; Momomura, Shin-Ichi; Seino, Yoshihiko; Sato, Yasunori; Inoue, Teruo; Node, Koichi
2018-02-15
Home telemonitoring is becoming more important to home medical care for patients with heart failure. Since there are no data on home telemonitoring for Japanese patients with heart failure, we investigated its effect on cardiovascular outcomes. The HOMES-HF study was the first multicenter, open-label, randomized, controlled trial (RCT) to elucidate the effectiveness of home telemonitoring of physiological data, such as body weight, blood pressure, and pulse rate, for Japanese patients with heart failure (UMIN Clinical Trials Registry 000006839). The primary end-point was a composite of all-cause death or rehospitalization due to worsening heart failure. We analyzed 181 recently hospitalized patients with heart failure who were randomly assigned to a telemonitoring group (n = 90) or a usual care group (n = 91). The mean follow-up period was 15 (range 0-31) months. There was no statistically significant difference in the primary end-point between groups [hazard ratio (HR), 0.95; 95% confidence interval (CI), 0.548-1.648; p = 0.572]. Home telemonitoring for Japanese patients with heart failure was feasible; however, beneficial effects in addition to those of usual care were not demonstrated. Further investigation of more patients with severe heart failure, participation of home medical care providers, and use of a more integrated home telemonitoring system emphasizing communication as well as monitoring of symptoms and physiological data are required.
A case of adverse drug reaction induced by dispensing error.
Gallelli, L; Staltari, O; Palleria, C; Di Mizio, G; De Sarro, G; Caroleo, B
2012-11-01
To report about a case of acute renal failure due to absence of communication between physician and patient. A 78 year old man with human immunodeficiency virus (HIV) accessed our hospital and was brought to our attention in August 2011 for severe renal failure. Clinical history revealed that he had been taking highly active antiretroviral therapy with lamivudine/abacavir and fosamprenavir since 2006. In April 2011 due to an augmentation in creatinine plasma levels, a reduction in lamivudine dosage to 100 mg/day and the prescription of abacavir 300 mg/day became necessary. Unfortunately, the patient took both lamivudine and abacavir therefore the association of the two medications (lamivudine/abacavir) lead to asthenia and acute renal failure within a few days. This case emphasizes the importance about how physicians must pay very careful attention during drug prescription, most particularly, as far as elderly patients are concerned. In fact, communication improvement between physicians and patients can prevent increase of adverse drug reactions related to drug dispensing, with consequential reduction of costs in the healthcare system. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
GenSo-EWS: a novel neural-fuzzy based early warning system for predicting bank failures.
Tung, W L; Quek, C; Cheng, P
2004-05-01
Bank failure prediction is an important issue for the regulators of the banking industries. The collapse and failure of a bank could trigger an adverse financial repercussion and generate negative impacts such as a massive bail out cost for the failing bank and loss of confidence from the investors and depositors. Very often, bank failures are due to financial distress. Hence, it is desirable to have an early warning system (EWS) that identifies potential bank failure or high-risk banks through the traits of financial distress. Various traditional statistical models have been employed to study bank failures [J Finance 1 (1975) 21; J Banking Finance 1 (1977) 249; J Banking Finance 10 (1986) 511; J Banking Finance 19 (1995) 1073]. However, these models do not have the capability to identify the characteristics of financial distress and thus function as black boxes. This paper proposes the use of a new neural fuzzy system [Foundations of neuro-fuzzy systems, 1997], namely the Generic Self-organising Fuzzy Neural Network (GenSoFNN) [IEEE Trans Neural Networks 13 (2002c) 1075] based on the compositional rule of inference (CRI) [Commun ACM 37 (1975) 77], as an alternative to predict banking failure. The CRI based GenSoFNN neural fuzzy network, henceforth denoted as GenSoFNN-CRI(S), functions as an EWS and is able to identify the inherent traits of financial distress based on financial covariates (features) derived from publicly available financial statements. The interaction between the selected features is captured in the form of highly intuitive IF-THEN fuzzy rules. Such easily comprehensible rules provide insights into the possible characteristics of financial distress and form the knowledge base for a highly desired EWS that aids bank regulation. The performance of the GenSoFNN-CRI(S) network is subsequently benchmarked against that of the Cox's proportional hazards model [J Banking Finance 10 (1986) 511; J Banking Finance 19 (1995) 1073], the multi-layered perceptron (MLP) and the modified cerebellar model articulation controller (MCMAC) [IEEE Trans Syst Man Cybern: Part B 30 (2000) 491] in predicting bank failures based on a population of 3635 US banks observed over a 21 years period. Three sets of experiments are performed-bank failure classification based on the last available financial record and prediction using financial records one and two years prior to the last available financial statements. The performance of the GenSoFNN-CRI(S) network as a bank failure classification and EWS is encouraging.
Evidence of an Emerging Disturbance of Earthen Levees Causing Disastrous Floods in Italy
NASA Astrophysics Data System (ADS)
Orlandini, S.; Moretti, G.; Albertson, J. D.
2015-12-01
A levee failure occurred along the Secchia River, Northern Italy, on January 19, 2014, resulting in flood damage in excess of $500 Million (Figure). In response to this failure, immediate surveillance of other levees in the region led to the identification of a second breach developing on the neighboring Panaro River, where rapid mitigation efforts were successful in averting a full levee failure. The paired breach events that occurred along the Secchia and Panaro Rivers provided an excellent window on an emerging disturbance of levees and related failure mechanism. In the Secchia River, by combining the information content of photographs taken from helicopters in the early stage of breach development and 10-cm resolution aerial photographs taken in 2010 and 2012, animal burrows were found to exist in the precise levee location where the breach originated. In the Panaro River, internal erosion was observed to occur at a location where a crested porcupine den was known to exist and this erosion led to the collapse of the levee top. Evidence collected suggested that it is quite likely that the levee failure of the Secchia River was of a similar mechanism as the observed failure of the Panaro River. Detailed numerical modeling of rainfall, river flow, and variably saturated flow occurring in disturbed levees in response to complex hydroclimatic forcing indicated that the levee failure of the Secchia River may have been triggered by direct river inflow into the den system or collapse of a hypothetical den separated by a 1-m earthen wall from the levee riverside, which saturated during the hydroclimatic event. It is important to bring these processes to the attention of hydrologists and geotechnical engineers as well as to trigger an interdisciplinary discussion on habitat fragmentation and wildlife shifts due to development and climate pressures. These disturbances come together with changes in extreme events to inform the broader concern of risk analysis due to floods.
NASA Technical Reports Server (NTRS)
Coleman, Anthony S.; Hansen, Irving G.
1994-01-01
NASA is pursuing a program in Advanced Subsonic Transport (AST) to develop the technology for a highly reliable Fly-By-Light/Power-By-WIre aircraft. One of the primary objectives of the program is to develop the technology base for confident application of integrated PBW components and systems to transport aircraft to improve operating reliability and efficiency. Technology will be developed so that the present hydraulic and pneumatic systems of the aircraft can be systematically eliminated and replaced by electrical systems. These motor driven actuators would move the aircraft wing surfaces as well as the rudder to provide steering controls for the pilot. Existing aircraft electrical systems are not flight critical and are prone to failure due to Electromagnetic Interference (EMI) (1), ground faults and component failures. In order to successfully implement electromechanical flight control actuation, a Power Management and Distribution (PMAD) System must be designed having a reliability of 1 failure in 10(exp +9) hours, EMI hardening and a fault tolerance architecture to ensure uninterrupted power to all aircraft flight critical systems. The focus of this paper is to analyze, define, and describe technically challenging areas associated with the development of a Power By Wire Aircraft and typical requirements to be established at the box level. The authors will attempt to propose areas of investigation, citing specific military standards and requirements that need to be revised to accommodate the 'More Electric Aircraft Systems'.
Status and Evaluation of Microwave Furnace Capabilities at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Lizcano, Maricela; Mackey, Jonathan A.
2014-01-01
The microwave (MW) furnace is a HY-Tech Microwave Systems, 2 kW 2.45 GHz Single Mode Microwave Applicator operating in continuous wave (CW) with variable power. It is located in Cleveland, Ohio at NASA Glenn Research Center. Until recently, the furnace capabilities had not been fully realized due to unknown failure that subsequently damaged critical furnace components. Although the causes of the problems were unknown, an assessment of the furnace itself indicated operational failure may have been partially caused by power quality. This report summarizes the status of the MW furnace and evaluates its capabilities in materials processing.
[Left-sided native valve endocarditis by coagulase-negative staphylococci: an emerging disease].
Haro, Juan Luis; Lomas, José M; Plata, Antonio; Ruiz, Josefa; Gálvez, Juan; de la Torre, Javier; Hidalgo-Tenorio, Carmen; Reguera, José M; Márquez, Manuel; Martínez-Marcos, Francisco; de Alarcón, Arístides
2008-05-01
To describe the epidemiological, clinical, and prognostic characteristics of patients with left-sided native valve endocarditis (LNVE) caused by coagulase-negative staphylococci (CoNS). Prospective multicenter study of endocarditis cases reported in the Andalusian Cohort for the Study of Cardiovascular Infections between 1984 and 2005. Among 470 cases of LNVE, 39 (8.3%) were caused by CoNS, a number indicating a 30% increase in the incidence of this infection over the last decade. The mean age of affected patients was 58.32 +/- 15 years and 27 (69.2%) were men. Twenty-one patients (53.8%) had previous known valve disease and half the episodes were considered nosocomial (90% of them from vascular procedures). Median time interval from the onset of symptoms to diagnosis was 14 days (range: 1-120). Renal failure (21 cases, 53.8%), intracardiac damage (11 cases, 28.2%), and central nervous system involvement (10 cases, 25.6%) were the most frequent complications. There were only 3 cases (7.7%) of septic shock. Surgery was performed in 18 patients (46.2%). Nine patients (23.1%) died, overall. Factors associated with higher mortality in the univariate analysis were acute renal failure (P = 0.023), left-sided ventricular failure (P = 0.047), and time prior to diagnosis less than 21 days (P = 0.018). As compared to LNVE due to other microorganisms, the patients were older (P = 0.018), had experienced previous nosocomial manipulation as the source of bacteremia (P < 0.001), and developed acute renal failure more frequently (P = 0.001). Mortality of LNVE due to CoNS was lower than mortality in Staphylococcus aureus infection, but higher than in Streptococcus viridans infection. Left-sided native valve endocarditis due to CoNS is now increasing because of the ageing of the population. This implies more frequent invasive procedures (mainly vascular) as a consequence of the concomitant disease. Nonetheless, the mortality associated with LNVE due to CoNS does not seem to be greater than infection caused by other pathogens.
Li-Ion Battery By-Pass Removal Qualification
NASA Astrophysics Data System (ADS)
Borthomieu, Y.; Pasquier, E.
2005-05-01
The reasons of the by-pass use on Space batteries is to avoid open circuit, short-circuit and dramatic performances drift on the power system. By-pass diodes are currently used in NiH2 batteries due to the high probability of open circuit at cell level. This probability is mainly linked to the possibility to have a hydrogen leak within the pressure vessel due to the high operating pressure (70 bars) that can induce cell open circuit.For the Lithium-Ion batteries, first items had bypass implemented by similarity, but:All the cell failure cases have been analyzed at battery level:- Cell Open circuit:In contrast to NiCd and NiH2 cells, Li-Ion cells can be put in parallel due to the fact the open circuit voltage (OCV) is linked to the State Of Charge (SOC).With cells in parallel, a battery open circuit failure can never be encountered even with a cell in open circuit.- Cell Short circuit:In case of cell short, the entire cells within the module will be shorted.- Cell capacity spread:If the capacities of cells in series are strongly diverging, the worst module limits the battery. In case the battery is no more able to deliver the requested power for which it was designed, the worst module has to be reversed. In reversal, a Li-Ion cell is self-shorted. So, the strong capacity decrease in one module leads to the short of this module.These three failure cases cover all the possible Li-Ion failure root causes.Considering these three events, the analysis demonstrates that the Li-Ion battery still functions in any case without any by-pass system because the design of the battery size always takes into account the loss of one module.Nevertheless, the by-pass removal should allow to:- Improve the battery reliability as each bypass unit represents a single - Reduce by at least 30 % of the total price of the battery,- Reduce significant weight at battery level,- Shorten the battery manufacturing lead time (at least8 months for by-pass purchasing), - Avoid US export licenses.A formal qualification of a Li-Ion battery without by- pass system is on going in the frame of an ESA ARTES 3 contract.
State Liability for Abuse in Primary Schools: Systemic Failure and "O'Keeffe" v. "Hickey"
ERIC Educational Resources Information Center
O'Mahony, Conor
2009-01-01
Due to the historical arrangement between Church and State, the Irish State has always discharged its duty to provide for free primary education exclusively through the provision of funding to privately owned and managed schools. Consequently, in "O'Keeffe" v. "Hickey," where a woman sued the State in respect of sex abuse she…
Self-Government as a System of Education (1931)
ERIC Educational Resources Information Center
Carillo, Francisco
2011-01-01
One of the most important problems in education is that of inculcating a sense of citizenship. Most of the social and political disturbances in the world are due to the failure to perform duties and the false interpretation of rights--both apparently the outcome of ignorance. For that reason, it is most important that children should be accustomed…
77 FR 20572 - Airworthiness Directives; BAE Systems (Operations) Limited Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-05
... at the water trap/air drier unit of the forward discharge valve due to corrosion. This proposed AD... failure of the fuselage skin, leading to a possible sudden loss of cabin pressure. DATES: We must receive... surface anomalies (bulges and/or dents) of the fuselage skin at the water trap/air drier unit of the...
McrEngine: A Scalable Checkpointing System Using Data-Aware Aggregation and Compression
Islam, Tanzima Zerin; Mohror, Kathryn; Bagchi, Saurabh; ...
2013-01-01
High performance computing (HPC) systems use checkpoint-restart to tolerate failures. Typically, applications store their states in checkpoints on a parallel file system (PFS). As applications scale up, checkpoint-restart incurs high overheads due to contention for PFS resources. The high overheads force large-scale applications to reduce checkpoint frequency, which means more compute time is lost in the event of failure. We alleviate this problem through a scalable checkpoint-restart system, mcrEngine. McrEngine aggregates checkpoints from multiple application processes with knowledge of the data semantics available through widely-used I/O libraries, e.g., HDF5 and netCDF, and compresses them. Our novel scheme improves compressibility ofmore » checkpoints up to 115% over simple concatenation and compression. Our evaluation with large-scale application checkpoints show that mcrEngine reduces checkpointing overhead by up to 87% and restart overhead by up to 62% over a baseline with no aggregation or compression.« less
NASA Astrophysics Data System (ADS)
Lin, Yi-Kuei; Huang, Cheng-Fu
2015-04-01
From a quality of service viewpoint, the transmission packet unreliability and transmission time are both critical performance indicators in a computer system when assessing the Internet quality for supervisors and customers. A computer system is usually modelled as a network topology where each branch denotes a transmission medium and each vertex represents a station of servers. Almost every branch has multiple capacities/states due to failure, partial failure, maintenance, etc. This type of network is known as a multi-state computer network (MSCN). This paper proposes an efficient algorithm that computes the system reliability, i.e., the probability that a specified amount of data can be sent through k (k ≥ 2) disjoint minimal paths within both the tolerable packet unreliability and time threshold. Furthermore, two routing schemes are established in advance to indicate the main and spare minimal paths to increase the system reliability (referred to as spare reliability). Thus, the spare reliability can be readily computed according to the routing scheme.
Investigating an API for resilient exascale computing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stearley, Jon R.; Tomkins, James; VanDyke, John P.
2013-05-01
Increased HPC capability comes with increased complexity, part counts, and fault occurrences. In- creasing the resilience of systems and applications to faults is a critical requirement facing the viability of exascale systems, as the overhead of traditional checkpoint/restart is projected to outweigh its bene ts due to fault rates outpacing I/O bandwidths. As faults occur and propagate throughout hardware and software layers, pervasive noti cation and handling mechanisms are necessary. This report describes an initial investigation of fault types and programming interfaces to mitigate them. Proof-of-concept APIs are presented for the frequent and important cases of memory errors and nodemore » failures, and a strategy proposed for lesystem failures. These involve changes to the operating system, runtime, I/O library, and application layers. While a single API for fault handling among hardware and OS and application system-wide remains elusive, the e ort increased our understanding of both the mountainous challenges and the promising trailheads. 3« less
Naughton, Matthew T; Lorenzi-Filho, Geraldo
2009-01-01
Sleep plays a large role in patients with heart failure. In normal subjects, sleep is usually in a supine position with reduced sympathetic drive, elevated vagal tone and as such a relatively lower cardiac output and minute ventilation, allowing for recuperation. Patients with heart failure may not experience the same degree of autonomic activity change and the supine position may place a large strain on the pulmonary system. More than half of all heart failure patients have one of two types of sleep apnea: either obstructive or central sleep apnea. Some patients have both types. Obstructive sleep apnea is likely to be a cause of heart failure due to large negative intrathoracic pressures, apnea related hypoxemia and hypercapnia, terminated by an arousal and surge in systemic blood pressure associated with endothelial damage and resultant premature atherosclerosis. Reversal of obstructive sleep apnea improves blood pressure, systolic contraction and autonomic dysfunction however mortality studies are lacking. Central sleep apnea with Cheyne Stokes pattern of respiration (CSA-CSR) occurs as a result of increased central controller (brainstem driving ventilation) and plant (ventilation driving CO2) gain in the setting of a delayed feed back (i.e., low cardiac output). It is thought this type of apnea is a result of moderately to severely impaired cardiac function and is possibly indicative of high mortality. Treatment of CSA-CSR is best undertaken by treating the underlying cardiac condition which may include with medications, pacemakers, transplantation or continuous positive airway pressure (CPAP). In such patients CPAP exerts unique effects to assist cardiac function and reduce pulmonary edema. Whether CPAP improves survival in this heart failure population remains to be determined.
Investigation of a fatigue failure in a stainless steel femoral plate.
Marcomini, J B; Baptista, C A R P; Pascon, J P; Teixeira, R L; Reis, F P
2014-10-01
Surgical implants are exposed to severe working conditions and therefore a wide range of failure mechanisms may occur, including fatigue, corrosion, wear, fretting and combinations of them. The mechanical failures of metallic implants may also be influenced by several other factors, including the design, material, manufacturing, installation, postoperative complications and misuse. An 83-year-old patient suffered an oblique femoral shaft fracture due to a fall at home. A stainless steel locking compression plate (LCP) employed in the fracture reduction failed after four months and was sent back to the producer. A second LCP of the same type was implanted and also failed after six months. A failure analysis of the second femoral LCP is performed in this paper. The results demonstrate that poor material quality was decisive to the failure. The chemical analysis revealed a high P content in the steel, which is not in accordance to the standards. A combination of factors lead to LCP fracture and these include: brittle crack initiation due to phosphorus, segregation at grain boundaries, crack propagation due to cyclic loading and final fast fracture favored by the loss of ductility due to cold work. Copyright © 2014 Elsevier Ltd. All rights reserved.
Design and implementation of a novel mechanical testing system for cellular solids.
Nazarian, Ara; Stauber, Martin; Müller, Ralph
2005-05-01
Cellular solids constitute an important class of engineering materials encompassing both man-made and natural constructs. Materials such as wood, cork, coral, and cancellous bone are examples of cellular solids. The structural analysis of cellular solid failure has been limited to 2D sections to illustrate global fracture patterns. Due to the inherent destructiveness of 2D methods, dynamic assessment of fracture progression has not been possible. Image-guided failure assessment (IGFA), a noninvasive technique to analyze 3D progressive bone failure, has been developed utilizing stepwise microcompression in combination with time-lapsed microcomputed tomographic imaging (microCT). This method allows for the assessment of fracture progression in the plastic region, where much of the structural deformation/energy absorption is encountered in a cellular solid. Therefore, the goal of this project was to design and fabricate a novel micromechanical testing system to validate the effectiveness of the stepwise IGFA technique compared to classical continuous mechanical testing, using a variety of engineered and natural cellular solids. In our analysis, we found stepwise compression to be a valid approach for IGFA with high precision and accuracy comparable to classical continuous testing. Therefore, this approach complements the conventional mechanical testing methods by providing visual insight into the failure propagation mechanisms of cellular solids. (c) 2005 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Huang, Zhiqiang; Xie, Dou; Xie, Bing; Zhang, Wenlin; Zhang, Fuxiao; He, Lei
2018-03-01
The undesired stick-slip vibration is the main source of PDC bit failure, such as tooth fracture and tooth loss. So, the study of PDC bit failure base on stick-slip vibration analysis is crucial to prolonging the service life of PDC bit and improving ROP (rate of penetration). For this purpose, a piecewise-smooth torsional model with 4-DOF (degree of freedom) of drilling string system plus PDC bit is proposed to simulate non-impact drilling. In this model, both the friction and cutting behaviors of PDC bit are innovatively introduced. The results reveal that PDC bit is easier to fail than other drilling tools due to the severer stick-slip vibration. Moreover, reducing WOB (weight on bit) and improving driving torque can effectively mitigate the stick-slip vibration of PDC bit. Therefore, PDC bit failure can be alleviated by optimizing drilling parameters. In addition, a new 4-DOF torsional model is established to simulate torsional impact drilling and the effect of torsional impact on PDC bit's stick-slip vibration is analyzed by use of an engineering example. It can be concluded that torsional impact can mitigate stick-slip vibration, prolonging the service life of PDC bit and improving drilling efficiency, which is consistent with the field experiment results.
On the occurrence of rainstorm damage based on home insurance and weather data
NASA Astrophysics Data System (ADS)
Spekkers, M. H.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.
2014-08-01
Rainstorm damage caused by malfunctioning of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage are investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. Records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. Results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7-8 mm in a 60 min window are mainly related to failures processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7-8 mm h-1 threshold, failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to extent to which sewer-related claims were caused by overloading of sewer systems or failure of system components.
On the occurrence of rainstorm damage based on home insurance and weather data
NASA Astrophysics Data System (ADS)
Spekkers, M. H.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.
2015-02-01
Rainstorm damage caused by the malfunction of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage is investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. The records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. The results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7-8 mm in a 60-min window are mainly related to failure processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7-8 mm h-1 threshold, the failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to which extent sewer-related claims were caused by overloading of sewer systems or failure of system components.
Lawrence, Braden J; Petersen, Emily L; Riches, Wayne G; Pfeiffer, David C
2018-06-06
Plasmacytomas are rare immunoproliferative monoclonal plasma cell diseases of lymphoid lineage that may present in an isolated or systemic manner. Systemic involvement is much more common than occurrences isolated to a particular organ, and for this reason, it is imperative to rule out systemic involvement for osseous and nonosseous isolated neoplasms. These neoplasms present unique challenges due to their location, extent of involvement, vague presentation, and dearth of treatment protocol. We report the case of a 69-year-old man who developed chronic kidney disease stage 4 between 2009 and 2012. Precipitous kidney failure, anorexia, fatigue, and flank pain necessitated clinical follow-up that ultimately led to thorough imaging and bilateral kidney biopsy. Protein electrophoresis, immunohistochemistry, and immunofluorescence were all consistent with bilateral renal extramedullary plasmacytomas. Treatment recommendations are often limited to prior case successes; however, chemotherapy, radiation, and surgery are the mainstay of treatment. Although surgery or combined therapy provides the best results for patients, such options are unfeasible with bilateral kidney involvement. Therefore, a chemotherapy regimen, similar to that for multiple myeloma, was determined to be most reasonable. Treatment consisted of 4 cycles of a bortezomib, cyclophosphamide, and dexamethasone regimen. Three months following chemotherapy, kidney function returned to baseline levels. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Random Vibration Testing of Advanced Wet Tantalum Capacitors
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander
2015-01-01
Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.
NASA Technical Reports Server (NTRS)
Srivastava, Ashok N.; Mylaraswmay, Dinkar; Mah, Robert W.; Cooper, Eric G.
2011-01-01
At the aircraft level, a Vehicle-Level Reasoning System (VLRS) can be developed to provide aircraft with at least two significant capabilities: improvement of aircraft safety due to enhanced monitoring and reasoning about the aircrafts health state, and also potential cost savings by enabling Condition Based Maintenance (CBM). Along with the benefits of CBM, an important challenge facing aviation safety today is safeguarding against system and component failures and malfunctions. Faults can arise in one or more aircraft subsystem their effects in one system may propagate to other subsystems, and faults may interact.
Novel Corrosion Sensor for Vision 21 Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heng Ban; Bharat Soni
2007-03-31
Advanced sensor technology is identified as a key component for advanced power systems for future energy plants that would have virtually no environmental impact. This project intends to develop a novel high temperature corrosion sensor and subsequent measurement system for advanced power systems. Fireside corrosion is the leading mechanism for boiler tube failures and has emerged to be a significant concern for current and future energy plants due to the introduction of technologies targeting emissions reduction, efficiency improvement, or fuel/oxidant flexibility. Corrosion damage can lead to catastrophic equipment failure, explosions, and forced outages. Proper management of corrosion requires real-time indicationmore » of corrosion rate. However, short-term, on-line corrosion monitoring systems for fireside corrosion remain a technical challenge to date due to the extremely harsh combustion environment. The overall goal of this project is to develop a technology for on-line fireside corrosion monitoring. This objective is achieved by the laboratory development of sensors and instrumentation, testing them in a laboratory muffle furnace, and eventually testing the system in a coal-fired furnace. This project successfully developed two types of sensors and measurement systems, and successful tested them in a muffle furnace in the laboratory. The capacitance sensor had a high fabrication cost and might be more appropriate in other applications. The low-cost resistance sensor was tested in a power plant burning eastern bituminous coals. The results show that the fireside corrosion measurement system can be used to determine the corrosion rate at waterwall and superheater locations. Electron microscope analysis of the corroded sensor surface provided detailed picture of the corrosion process.« less
Preliminary calculations related to the accident at Three Mile Island
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirchner, W.L.; Stevenson, M.G.
This report discusses preliminary studies of the Three Mile Island Unit 2 (TMI-2) accident based on available methods and data. The work reported includes: (1) a TRAC base case calculation out to 3 hours into the accident sequence; (2) TRAC parametric calculations, these are the same as the base case except for a single hypothetical change in the system conditions, such as assuming the high pressure injection (HPI) system operated as designed rather than as in the accident; (3) fuel rod cladding failure, cladding oxidation due to zirconium metal-steam reactions, hydrogen release due to cladding oxidation, cladding ballooning, cladding embrittlement,more » and subsequent cladding breakup estimates based on TRAC calculated cladding temperatures and system pressures. Some conclusions of this work are: the TRAC base case accident calculation agrees very well with known system conditions to nearly 3 hours into the accident; the parametric calculations indicate that, loss-of-core cooling was most influenced by the throttling of High-Pressure Injection (HPI) flows, given the accident initiating events and the pressurizer electromagnetic-operated valve (EMOV) failing to close as designed; failure of nearly all the rods and gaseous fission product gas release from the failed rods is predicted to have occurred at about 2 hours and 30 minutes; cladding oxidation (zirconium-steam reaction) up to 3 hours resulted in the production of approximately 40 kilograms of hydrogen.« less
Reliability Estimation of Aero-engine Based on Mixed Weibull Distribution Model
NASA Astrophysics Data System (ADS)
Yuan, Zhongda; Deng, Junxiang; Wang, Dawei
2018-02-01
Aero-engine is a complex mechanical electronic system, based on analysis of reliability of mechanical electronic system, Weibull distribution model has an irreplaceable role. Till now, only two-parameter Weibull distribution model and three-parameter Weibull distribution are widely used. Due to diversity of engine failure modes, there is a big error with single Weibull distribution model. By contrast, a variety of engine failure modes can be taken into account with mixed Weibull distribution model, so it is a good statistical analysis model. Except the concept of dynamic weight coefficient, in order to make reliability estimation result more accurately, three-parameter correlation coefficient optimization method is applied to enhance Weibull distribution model, thus precision of mixed distribution reliability model is improved greatly. All of these are advantageous to popularize Weibull distribution model in engineering applications.
Becker, Murray; Goldszal, Alberto; Detal, Julie; Gronlund-Jacob, Judith; Epstein, Robert
2015-06-01
The aim of this study was to assess whether the complex radiology IT infrastructures needed for large, geographically diversified, radiology practices are inherently stable with respect to system downtimes, and to characterize the nature of the downtimes to better understand their impact on radiology department workflow. All radiology IT unplanned downtimes over a 12-month period in a hybrid academic-private practice that performs all interpretations in-house (no commercial "nighthawk" services) for approximately 900,000 studies per year, originating at 6 hospitals, 10 outpatient imaging centers, and multiple low-volume off-hours sites, were logged and characterized using 5 downtime metrics: duration, etiology, failure type, extent, and severity. In 12 consecutive months, 117 unplanned downtimes occurred with the following characteristics: duration: median time = 3.5 hours with 34% <1.5 hours and 30% >12 hours; etiology: 87% were due to software malfunctions, and 13% to hardware malfunctions; failure type: 88% were transient component failures, 12% were complete component failures; extent: all sites experienced downtimes, but downtimes were always localized to a subset of sites, and no system-wide downtimes occurred; severity (impact on radiologist workflow): 47% had minimal impact, 50% moderate impact, and 3% severe impact. In the complex radiology IT system that was studied, downtimes were common; they were usually a result of transient software malfunctions; the geographic extent was always localized rather than system wide; and most often, the impacts on radiologist workflow were modest. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Real-time diagnostics of the reusable rocket engine using on-line system identification
NASA Technical Reports Server (NTRS)
Guo, T.-H.; Merrill, W.; Duyar, A.
1990-01-01
A model-based failure diagnosis system has been proposed for real-time diagnosis of SSME failures. Actuation, sensor, and system degradation failure modes are all considered by the proposed system. In the case of SSME actuation failures, it was shown that real-time identification can effectively be used for failure diagnosis purposes. It is a direct approach since it reduces the detection, isolation, and the estimation of the extent of the failures to the comparison of parameter values before and after the failure. As with any model-based failure detection system, the proposed approach requires a fault model that embodies the essential characteristics of the failure process. The proposed diagnosis approach has the added advantage that it can be used as part of an intelligent control system for failure accommodation purposes.
Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Burchfield, David E.; Pargellis, Andrew; Tissandier, Amber; Erwin, Phillip M.; Thoresen, Souzan; Gentry, Greg; Granahan, John; Matty, Chris
2012-01-01
The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. It is an integral part of the Environmental Control and Life Support System (ECLSS). The MCA system is comprised of seven orbit-replaceable units (ORUs) that provide flexibility in maintaining the MCA. Of these, ORU 02, the analyzer assembly requires replacement every 1 to 2 years due to the consumption of limited life components including the ion pump and ion source filaments. Typically, ORU 02s that reach end of life are swapped out of the MCA on orbit and replaced with the on-orbit spare. The replaced ORU 02 is then cycled through the OEM for refurbishment and returned to service. Recently, two refurbished ORU 02s, serial numbers F0001 and F0003, failed on orbit shortly after being installed into the MCA. Both ORU 02s were returned to ground for TT&E and a failure investigation. The failure signatures were reproduced on the ground and the investigation determined that both ORU 02 failures involve either the ion source or the ion source control electronics. This paper discusses the results of the failure investigation, the steps required to refurbish the ORU 02s, and the corrective actions that are being incorporated into the build and refurbishment process to preclude the reoccurrence of these failures in the future.
Investigation into Cause of High Temperature Failure of Boiler Superheater Tube
NASA Astrophysics Data System (ADS)
Ghosh, D.; Ray, S.; Roy, H.; Shukla, A. K.
2015-04-01
The failure of the boiler tubes occur due to various reasons like creep, fatigue, corrosion and erosion. This paper highlights a case study of typical premature failure of a final superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement, chemical analysis, oxide scale thickness measurement, microstructural examination are conducted as part of the investigations. Apart from these investigations, sulfur print, Energy Dispersive spectroscopy (EDS) and X ray diffraction analysis (XRD) are also conducted to ascertain the probable cause of failure of final super heater tube. Finally it has been concluded that the premature failure of the super heater tube can be attributed to the combination of localized high tube metal temperature and loss of metal from the outer surface due to high temperature corrosion. The corrective actions have also been suggested to avoid this type of failure in near future.
Spacecraft Electrical Connector Selection and Application Processes
NASA Technical Reports Server (NTRS)
Iannello, Chris; Davis, Mitchell I; Kichak, Robert A.; Slenski, George
2009-01-01
This assessment was initiated by the NASA Engineering & Safety Center (NESC) after a number of recent "high profile" connector problems, the most visible and publicized of these being the problem with the Space Shuttle's Engine Cut-Off System cryogenic feed-thru connector. The NESC commissioned a review of NASA's connector selection and application processes for space flight applications, including how lessons learned and past problem records are fed back into the processes to avoid recurring issues. Team members were primarily from the various NASA Centers and included connector and electrical parts specialists. The commissioned study was conducted on spacecraft connector selection and application processes at NASA Centers. The team also compared the NASA spacecraft connector selection and application process to the military process, identified recent high profile connector failures, and analyzed problem report data looking for trends and common occurrences. The team characterized NASA's connector problem experience into a list of top connector issues based on anecdotal evidence of a system's impact and commonality between Centers. These top issues are as follows, in no particular rank order: electrically shorted, bent and/or recessed contact pins, contact pin/socket contamination leading to electrically open or intermittencies, connector plating corrosion or corrosion of connector components, low or inadequate contact pin retention forces, contact crimp failures, unmated connectors and mis-wiring due to workmanship errors during installation or maintenance, loose connectors due to manufacturing defects such as wavy washer and worn bayonet retention, damaged connector elastomeric seals and cryogenic connector failure. A survey was also conducted of SAE Connector AE-8C1 committee members regarding their experience relative to the NASA concerns on connectors. The most common responses in order of occurrence were contact retention, plating issues, worn-out or damaged coupling mechanisms, bent pins, contact crimp barrel cracking and torn seals. In addition to these common themes, responses included issues with markings, dimensional errors on the build, contact/socket damage (handling), manufacturing defects and customer misapplication and mishandling. The NESC team concluded that considering the large quantity and wide variety of connectors successfully flown on human and robotic space applications, the number of failures is quite low. However, "high profile" failures with significant cost, schedule, safety, and/or mission success impacts continue to occur. It was also concluded that connector failures occur throughout a system's life-cycle with the majority of connector issues application related. A number of recommendations were identified for improving NASA connector selection processes and overall space connector reliability and performance.
Potential benefits and hazards of increased reliance on cockpit automation
NASA Technical Reports Server (NTRS)
Wiener, Earl L.
1990-01-01
A review is presented of the introduction of advanced technology into the modern aircraft cockpit, bringing a new era of cockpit automation, and the opportunity for safe, fuel-efficient, computer-directed flight. It is shown that this advanced technology has also brought a number of problems, not due to equipment failure, but due to problems at the human-automation interface. Consideration is given to the interface, the ATC system, and to company, regulatory, and economic environments, as well as to how they contribute to these new problems.
Refractory pemphigus vulgaris treated with rituximab and mycophenolate mofetil*
Biot, Stephanie Del Rio Navarrete; Franco, Joanna Pimenta de Araujo; Lima, Ricardo Barbosa; Pereira, Henrique Novo Costa; Marques, Luiz Paulo José; Martins, Carlos José
2014-01-01
The main treatment for pemphigus vulgaris are systemic corticosteroids and immunosuppressive agents, but due to adverse reactions and therapeutic failure, new drugs such as rituximab and mycophenolate mofetil have been used. In this case report are described two cases of severe pemphigus vulgaris refractory to various treatments, with resolution after use of rituximab and mycophenolate mofetil, associated with corticosteroids. A higher-than-usual dose of rituximab was employed, without the occurrence of serious adverse reactions. Mycophenolate mofetil was added as adjunctive therapy due to lack of response to azathioprine. PMID:25387507
21 CFR 312.315 - Intermediate-size patient populations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... reasons or is unavailable through marketing due to failure to meet the conditions of the approved... through marketing due to failure to meet the conditions of the approved application or a drug shortage. (b... expanded access; and (2) There is at least preliminary clinical evidence of effectiveness of the drug, or...
On-Orbit Engineering and Vehicle Integration Poster Presentation
NASA Technical Reports Server (NTRS)
Heimerdinger, Madison
2014-01-01
One of the duties of the MER Managers is getting the consoles to review and sign Electronic Flight Notes (EFN) and Mission Action Requests (Chit) before they are due. Chits and EFNs and are accessible through the Mission Control Center - Houston (MCC-H) Gateway. Chits are the official means of documenting questions and answers, technical direction, real-time changes to Flight Rules (FR) and procedures, request for analysis, etc. between various consoles concerning on-orbit operations. EFNs are documents used by the Flight Control Team (FCT) to communicate precise details between console positions and manage real time changes to FR and Systems Operation Data File (SODF) procedures. On GMT 2013/345 the External Active Thermal Control System (EATCS) on the Columbus (COL) Moderate Temperature Loop (MTL) Interface Heat Exchanger (IFHX) shut down due to low temperatures. Over the next couple of days, the core temperature of COL MT IFHX dropped due to the failure of the Flow Control Valve (FCV). After the temperature drop was discovered, heaters were turned on to bring the temperatures back to nominal. After the incident occurred, a possible freeze threat was discovered that could have ruptured the heat exchanger. The COL MT IFHX rupturing would be considered a catastrophic failure and potentially result in a loss of the vehicle and/or the lives of the International Space Station (ISS) crew members
NASA Technical Reports Server (NTRS)
Hatfield, Glen S.; Hark, Frank; Stott, James
2016-01-01
Launch vehicle reliability analysis is largely dependent upon using predicted failure rates from data sources such as MIL-HDBK-217F. Reliability prediction methodologies based on component data do not take into account risks attributable to manufacturing, assembly, and process controls. These sources often dominate component level reliability or risk of failure probability. While consequences of failure is often understood in assessing risk, using predicted values in a risk model to estimate the probability of occurrence will likely underestimate the risk. Managers and decision makers often use the probability of occurrence in determining whether to accept the risk or require a design modification. Due to the absence of system level test and operational data inherent in aerospace applications, the actual risk threshold for acceptance may not be appropriately characterized for decision making purposes. This paper will establish a method and approach to identify the pitfalls and precautions of accepting risk based solely upon predicted failure data. This approach will provide a set of guidelines that may be useful to arrive at a more realistic quantification of risk prior to acceptance by a program.
Levy, Matthew; Oyenuga, Olusegun
2015-01-01
Fibrotic lung diseases carry a significant mortality burden worldwide. A large proportion of these deaths are due to right heart failure and pulmonary hypertension. Underlying contributory factors which appear to play a role in the mechanism of progression of right heart dysfunction include chronic hypoxia, defective calcium handling, hyperaldosteronism, pulmonary vascular alterations, cyclic strain of pressure and volume changes, elevation of circulating TGF-β, and elevated systemic NO levels. Specific therapies targeting pulmonary hypertension include calcium channel blockers, endothelin (ET-1) receptor antagonists, prostacyclin analogs, phosphodiesterase type 5 (PDE5) inhibitors, and rho-kinase (ROCK) inhibitors. Newer antifibrotic and anti-inflammatory agents may exert beneficial effects on heart failure in idiopathic pulmonary fibrosis. Furthermore, right ventricle-targeted therapies, aimed at mitigating the effects of functional right ventricular failure, include β-adrenoceptor (β-AR) blockers, angiotensin-converting enzyme (ACE) inhibitors, antioxidants, modulators of metabolism, and 5-hydroxytryptamine-2B (5-HT2B) receptor antagonists. Newer nonpharmacologic modalities for right ventricular support are increasingly being implemented. Early, effective, and individualized therapy may prevent overt right heart failure in fibrotic lung disease leading to improved outcomes and quality of life. PMID:26583148
NASA Technical Reports Server (NTRS)
Coats, Timothy William
1996-01-01
An investigation of translaminate fracture and a progressive damage methodology was conducted to evaluate and develop a residual strength prediction capability for laminated composites with through penetration notches. This is relevant to the damage tolerance of an aircraft fuselage that might suffer an in-flight accident such as an uncontained engine failure. An experimental characterization of several composite materials systems revealed an R-curve type of behavior. Fractographic examinations led to the postulate that this crack growth resistance could be due to fiber bridging, defined here as fractured fibers of one ply bridged by intact fibers of an adjacent ply. The progressive damage methodology is currently capable of predicting the initiation and growth of matrix cracks and fiber fracture. Using two difference fiber failure criteria, residual strength was predicted for different size panel widths and notch lengths. A ply discount fiber failure criterion yielded extremely conservative results while an elastic-perfectly plastic fiber failure criterion showed that the fiber bridging concept is valid for predicting residual strength for tensile dominated failure loads. Furthermore, the R-curves predicted by the model using the elastic-perfectly plastic fiber criterion compared very well with the experimental R-curves.
Common Cause Failures and Ultra Reliability
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A common cause failure occurs when several failures have the same origin. Common cause failures are either common event failures, where the cause is a single external event, or common mode failures, where two systems fail in the same way for the same reason. Common mode failures can occur at different times because of a design defect or a repeated external event. Common event failures reduce the reliability of on-line redundant systems but not of systems using off-line spare parts. Common mode failures reduce the dependability of systems using off-line spare parts and on-line redundancy.
Intelligent failure-tolerant control
NASA Technical Reports Server (NTRS)
Stengel, Robert F.
1991-01-01
An overview of failure-tolerant control is presented, beginning with robust control, progressing through parallel and analytical redundancy, and ending with rule-based systems and artificial neural networks. By design or implementation, failure-tolerant control systems are 'intelligent' systems. All failure-tolerant systems require some degrees of robustness to protect against catastrophic failure; failure tolerance often can be improved by adaptivity in decision-making and control, as well as by redundancy in measurement and actuation. Reliability, maintainability, and survivability can be enhanced by failure tolerance, although each objective poses different goals for control system design. Artificial intelligence concepts are helpful for integrating and codifying failure-tolerant control systems, not as alternatives but as adjuncts to conventional design methods.
On thermal stress failure of the SNAP-19A RTG heat shield
NASA Technical Reports Server (NTRS)
Pitts, W. C.; Anderson, L. A.
1974-01-01
Results of a study on thermal stress problems in an amorphous graphite heat shield that is part of the launch-abort protect system for the SNAP-19A radio-isotope thermoelectric generators (RTG) that will be used on the Viking Mars Lander are presended. The first result is from a thermal stress analysis of a full-scale RTG heat source that failed to survive a suborbital entry flight test, possibly due to thermal stress failure. It was calculated that the maximum stress in the heat shield was only 50 percent of the ultimate strength of the material. To provide information on the stress failure criterion used for this calculation, some heat shield specimens were fractured under abort entry conditions in a plasma arc facility. It was found that in regions free of stress concentrations the POCO graphite heat shield material did fracture when the local stress reached the ultimate uniaxial stress of the material.
Fokkinga, Wietske A; Kreulen, Cees M; Vallittu, Pekka K; Creugers, Nico H J
2004-01-01
This study sought to aggregate literature data on in vitro failure loads and failure modes of prefabricated fiber-reinforced composite (FRC) post systems and to compare them to those of prefabricated metal, custom-cast, and ceramic post systems. The literature was searched using MEDLINE from 1984 to 2003 for dental articles in English. Keywords used were (post or core or buildup or dowel) and (teeth or tooth). Additional inclusion/exclusion steps were conducted, each step by two independent readers: (1) Abstracts describing post-and-core techniques to reconstruct endodontically treated teeth and their mechanical and physical characteristics were included (descriptive studies or reviews were excluded); (2) articles that included FRC post systems were selected; (3) in vitro studies, single-rooted human teeth, prefabricated FRC posts, and composite as the core material were the selection criteria; and (4) failure loads and modes were extracted from the selected papers, and failure modes were dichotomized (distinction was made between "favorable failures," defined as reparable failures, and "unfavorable failures,"defined as irreparable [root] fractures). The literature search revealed 1,984 abstracts. Included were 244, 42, and 12 articles in the first, second, and third selection steps, respectively. Custom-cast post systems showed higher failure loads than prefabricated FRC post systems, whereas ceramic showed lower failure loads. Significantly more favorable failures occurred with prefabricated FRC post systems than with prefabricated and custom-cast metal post systems. The variable "post system" had a significant effect on mean failure loads. FRC post systems more frequently showed favorable failure modes than did metal post systems.
A Comparison of the American Common Core State Standards with the Finnish Educational System
ERIC Educational Resources Information Center
Lynch, Kelly
2014-01-01
With the failure of the No Child Left Behind policies of the 1990's, educational reformers wished to establish a "new and improved" set of standards for the United States to follow. However, since their inception in 2006-2007, the new Common Core State Standards have become increasingly unpopular due to the fact that they remain largely…
The Criteria of Adaptation of Primary School Pupils to the Academic Load of the Increased Intensity
ERIC Educational Resources Information Center
Telegina, Nadezhda V.; Belicheva, Tatyana V.
2016-01-01
The relevance of the research problem is due to applying various training programs in the modern education system which are supposed to increase teaching efficiency. In-depth study of some subjects at schools, lyceums and gymnasiums which starts in the elementary school quite often leads to tension and failures of adaptation process in innovative…
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Choi, Sung R.; Ghosn, Louis J.; Miller, rober A.
2005-01-01
Thermal barrier coatings will be more aggressively designed to protect gas turbine engine hot-section components in order to meet future engine higher fuel efficiency and lower emission goals. A fundamental understanding of the sintering and thermal cycling induced delamination of thermal barrier coating systems under engine-like heat flux conditions will potentially help to improve the coating temperature capability. In this study, a test approach is established to emphasize the real-time monitoring and assessment of the coating thermal conductivity, which can initially increase under the steady-state high temperature thermal gradient test due to coating sintering, and later decrease under the thermal gradient cyclic test due to coating cracking and delamination. Thermal conductivity prediction models have been established for a ZrO2-(7- 8wt%)Y2O3 model coating system in terms of heat flux, time, and testing temperatures. The coating delamination accumulation is then assessed based on the observed thermal conductivity response under the combined steady-state and cyclic thermal gradient tests. The coating thermal gradient cycling associated delaminations and failure mechanisms under simulated engine heat-flux conditions will be discussed in conjunction with the coating sintering and fracture testing results.
Clinical heterogeneity in autoimmune acute liver failure
Chavez-Tapia, Norberto C; Martinez-Salgado, Julio; Granados, Julio; Uribe, Misael; Tellez-Avila, Felix I
2007-01-01
AIM: To describe the outcome and prognosis in a cohort of patients with acute liver failure due to autoimmune hepatitis without liver transplantation. METHODS: A retrospective trial was conducted in 11 patients with acute liver failure due to autoimmune hepatitis who attended the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubiran. Demographic, biochemical and severity indexes, and treatment and outcome were assessed. RESULTS: Among the 11 patients, with a median age of 31 years, 72% had inflammatory response syndrome, and six patients received corticosteroids. The mortality rate within four weeks was 56%, and the one-year survival was 27%. In the survivors, severity indexes were lower and 83% received corticosteroids. CONCLUSION: We observed a relatively high survival rate in patients with acute liver failure due to autoimmune hepatitis. This survival rate could be influenced by severity of the disease and/or use of corticosteroids. PMID:17465474
Ishizuka, Masato; Yamada, Shintaro; Maemura, Sonoko; Yamamoto, Keisuke; Takizawa, Masataka; Uozumi, Hiroki; Minegishi, Sachito; Kobayashi, Jotaro; Ikenouchi, Hiroshi
2017-10-21
Atypical aortic coarctation (AAC) has been reported to occur anywhere along the aorta, except for the ascending aorta. The associated symptoms include hypotension in the lower half of the body, secondary hypertension in the upper half of the body, and heart failure. Here we present an 80-year-old Asian woman complaining of progressive exertional dyspnea. She was diagnosed with acute decompensated heart failure and kidney injury due to severely calcified stenosis of the thoracoabdominal aorta, the so called AAC. She received hemodiafiltration, and pulmonary congestion improved in part. Generally, surgical treatments are quite invasive in elderly patients. Endovascular stent graft placement is less invasive, however, fracture and rupture should be considered at severely calcified lesions like this case. Therefore, we selected extra-anatomical axillofemoral bypass. Her recovery after the surgery was remarkable. In a few days, she became free from hemodiafiltration, intravenous diuretics, and oxygen administration. We thought the contributive factors are the increase in kidney blood flow and the correction of afterload mismatch. The decrease in pulse pressure may reflect the reduction in systemic arterial compliance by axillofemoral bypass. The operative mortality of axillofemoral bypass was reported to be acceptable, although the patency of the axillofemoral bypass graft was not high enough. In conclusion, axillofemoral bypass is effective and feasible for elderly patients with acute decompensated heart failure and kidney injury due to AAC.
Dogan, Günes; Hanke, Jasmin; Puntigam, Jakob; Haverich, Axel; Schmitto, Jan D
2018-05-01
Giant-cell myocarditis represents a rare and often fatal autoimmune disorder. Despite extracorporeal life support being a valid treatment option, alternatives to control the underlying inflammatory response remain sparse. A new hemoadsorption device (CytoSorb) has recently been introduced to treat patients with an excessive inflammatory response. A 57-year-old patient developed fulminant right heart failure, respiratory insufficiency, hemodynamic instability, and oliguric-anuric renal failure. An extracorporeal life support together with an Impella was implanted for circulatory support. Due to non-pulsatility, acontractility of the left ventricle and a heavily reduced right ventricular function, a left ventricular assist device implantation and change from extracorporeal life support to veno-pulmonary arterial extracorporeal membrane oxygenation was performed. Since adequate hemodynamic stabilization could not be achieved and due to increasing inflammatory mediators and bilirubin levels, the decision was made to additionally integrate a CytoSorb hemoadsorber into the system. The combined treatment resulted in a clear and steady improvement in hemodynamics and the inflammatory condition with marked reductions in all measured parameters throughout the treatment period. Metabolic acidosis resolved and liver function improved. Extracorporeal life support therapy represents a bridging approach to heart transplantation or to cardiac recovery and can be complemented by CytoSorb as an independent therapeutic option. The patient described herein with giant-cell myocarditis and fulminant cardiac failure who received substantial extracorporeal support in combination with CytoSorb hemoadsorption therapy benefited in terms of an improvement of organ function and his inflammatory situation.
Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A
2006-02-01
Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was <0.35 mV-mV, then the detected rhythm was considered noise due to a lead failure. The first ICD-detected episode of lead failure and inappropriate detection from 24 ICD patients with a pace/sense lead failure and all ventricular arrhythmias from 56 ICD patients without a lead failure were selected. The stored data were analyzed to determine the sensitivity and specificity of the algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.
Gamell, Marc; Teranishi, Keita; Mayo, Jackson; ...
2017-04-24
By obtaining multi-process hard failure resilience at the application level is a key challenge that must be overcome before the promise of exascale can be fully realized. Some previous work has shown that online global recovery can dramatically reduce the overhead of failures when compared to the more traditional approach of terminating the job and restarting it from the last stored checkpoint. If online recovery is performed in a local manner further scalability is enabled, not only due to the intrinsic lower costs of recovering locally, but also due to derived effects when using some application types. In this papermore » we model one such effect, namely multiple failure masking, that manifests when running Stencil parallel computations on an environment when failures are recovered locally. First, the delay propagation shape of one or multiple failures recovered locally is modeled to enable several analyses of the probability of different levels of failure masking under certain Stencil application behaviors. These results indicate that failure masking is an extremely desirable effect at scale which manifestation is more evident and beneficial as the machine size or the failure rate increase.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamell, Marc; Teranishi, Keita; Mayo, Jackson
By obtaining multi-process hard failure resilience at the application level is a key challenge that must be overcome before the promise of exascale can be fully realized. Some previous work has shown that online global recovery can dramatically reduce the overhead of failures when compared to the more traditional approach of terminating the job and restarting it from the last stored checkpoint. If online recovery is performed in a local manner further scalability is enabled, not only due to the intrinsic lower costs of recovering locally, but also due to derived effects when using some application types. In this papermore » we model one such effect, namely multiple failure masking, that manifests when running Stencil parallel computations on an environment when failures are recovered locally. First, the delay propagation shape of one or multiple failures recovered locally is modeled to enable several analyses of the probability of different levels of failure masking under certain Stencil application behaviors. These results indicate that failure masking is an extremely desirable effect at scale which manifestation is more evident and beneficial as the machine size or the failure rate increase.« less
A simplified fragility analysis of fan type cable stayed bridges
NASA Astrophysics Data System (ADS)
Khan, R. A.; Datta, T. K.; Ahmad, S.
2005-06-01
A simplified fragility analysis of fan type cable stayed bridges using Probabilistic Risk Analysis (PRA) procedure is presented for determining their failure probability under random ground motion. Seismic input to the bridge support is considered to be a risk consistent response spectrum which is obtained from a separate analysis. For the response analysis, the bridge deck is modeles as a beam supported on spring at different points. The stiffnesses of the springs are determined by a separate 2D static analysis of cable-tower-deck system. The analysis provides a coupled stiffness matrix for the spring system. A continuum method of analysis using dynamic stiffness is used to determine the dynamic properties of the bridges. The response of the bridge deck is obtained by the response spectrum method of analysis as applied to multidegree of freedom system which duly takes into account the quasi-static component of bridge deck vibration. The fragility analysis includes uncertainties arising due to the variation in ground motion, material property, modeling, method of analysis, ductility factor and damage concentration effect. Probability of failure of the bridge deck is determined by the First Order Second Moment (FOSM) method of reliability. A three span double plane symmetrical fan type cable stayed bridge of total span 689 m, is used as an illustrative example. The fragility curves for the bridge deck failure are obtained under a number of parametric variations. Some of the important conclusions of the study indicate that (i) not only vertical component but also the horizontal component of ground motion has considerable effect on the probability of failure; (ii) ground motion with no time lag between support excitations provides a smaller probability of failure as compared to ground motion with very large time lag between support excitation; and (iii) probability of failure may considerably increase soft soil condition.
Wu, Meng-Ruey; Hsiao, Chia-Ying; Cheng, Chun-Han; Liao, Feng-Ching; Chao, Chuan-Lei; Chen, Chun-Yen; Yeh, Hung-I
2018-01-01
Introduction Paraquat poisoning can result in dysfunction of multiple organs, and pulmonary fibrosis with respiratory failure is the major cause of mortality. For terminally ill patients, some life-prolonging treatments can be non-beneficial treatments (NBT). The objective of this study was to determine if intubation is a NBT for patients with respiratory failure due to paraquat poisoning. Methods The study included 68 patients with respiratory failure due to paraquat poisoning. Patients were hospitalized at MacKay Memorial Hospital, Taitung Branch, Taiwan, between 2005 to April 2016. Composite outcomes of intra-hospital mortality, the rate of do-not-resuscitate (DNR) orders, prescribed medications, length of stay, and medical costs were recorded and compared between the do-not-intubate (DNI) group and endotracheal intubation (EI) group. Results Intra-hospital mortality rate for the entire population was 100%. There were significantly more patients with DNR orders in the DNI group (P = 0.007). There were no differences in the length of hospital stay. However, patients in DNI group had significantly less vasopressor use and more morphine use, shorter time in the intensive care unit, and fewer medical costs. Conclusion The procedure of intubation in patients with respiratory failure due to paraquat poisoning can be considered inappropriate life-prolonging treatment. PMID:29590187
Radha Krishna, Yellapu; Saraswat, Vivek Anand; Das, Khaunish; Himanshu, Goel; Yachha, Surender Kumar; Aggarwal, Rakesh; Choudhuri, Gour
2009-03-01
Acute hepatitis A and E are recognized triggers of hepatic decompensation in patients with cirrhosis, particularly from the Indian subcontinent. However, the resulting acute-on-chronic liver failure (ACLF) has not been well characterized and no large studies are available. Our study aimed to evaluate the clinical profile and predictors of 3-month mortality in patients with this distinctive form of liver failure. ACLF was diagnosed in patients with acute hepatitis A or E [abrupt rise in serum bilirubin and/or alanine aminotransferase with positive immunoglobulin M anti-hepatitis A virus (HAV)/anti-hepatitis E virus (HEV)] presenting with clinical evidence of liver failure (significant ascites and/or hepatic encephalopathy) and clinical, biochemical, endoscopic (oesophageal varices at least grade II in size), ultrasonographical (presence of nodular irregular liver with porto-systemic collaterals) or histological evidence of cirrhosis. Clinical and laboratory profile were evaluated, predictors of 3-month mortality were determined using univariate and multivariate logistic regression and a prognostic model was constructed. Receiver-operating curves were plotted to measure performance of the present prognostic model, model for end-stage liver disease (MELD) score and Child-Turcotte-Pugh (CTP) score. ACLF occurred in 121 (3.75%) of 3220 patients (mean age 36.3+/-18.0 years; M:F 85:36) with liver cirrhosis admitted from January 2000 to June 2006. It was due to HEV in 80 (61.1%), HAV in 33 (27.2%) and both in 8 (6.1%). The underlying liver cirrhosis was due to HBV (37), alcohol (17), Wilson's disease (8), HCV (5), autoimmune (6), Budd-Chiari syndrome (2), haemochromatosis (2) and was cryptogenic in the rest (42). Common presentations were jaundice (100%), ascites (78%) and hepatic encephalopathy (55%). Mean (SD) CTP score was 11.4+/-1.6 and mean MELD score was 28.6+/-9.06. Three-month mortality was 54 (44.6%). Complications seen were sepsis in 42 (31.8%), renal failure in 45 (34%), spontaneous bacterial peritonitis in 27 (20.5%), UGI bleeding in 15(11%) and hyponatraemia in 50 (41.3%). On univariate analysis, ascites, hepatic encephalopathy, renal failure, GI bleeding, total bilirubin, hyponatraemia and coagulopathy were significant predictors of mortality. Multivariate analysis revealed grades 3 and 4 HE [odds ratio (OR 32.1)], hyponatraemia (OR 9.2) and renal failure (OR 16.8) as significant predictors of 3-month mortality and a prognostic model using these predictors was constructed. Areas under the curve for the present predicted prognostic model, MELD, and CTP were 0.952, 0.941 and 0.636 respectively. ACLF due to hepatitis A or E super infection results in significant short-term mortality. The predictors of ominous outcome include grades 3 and 4 encephalopathy, hyponatraemia and renal failure. Present prognostic model and MELD scoring system were better predictors of 3-month outcome than CTP score in these patients. Early recognition of those with dismal prognosis may permit timely use of liver replacement/supportive therapies.
Lubnow, Matthias; Philipp, Alois; Foltan, Maik; Bull Enger, Tone; Lunz, Dirk; Bein, Thomas; Haneya, Assad; Schmid, Christof; Riegger, Günter; Müller, Thomas; Lehle, Karla
2014-01-01
Objectives Technical complications are a known hazard in veno-venous extracorporeal membrane oxygenation (vvECMO). Identifying these complications and predictive factors indicating a developing system-exchange was the goal of the study. Methods Retrospective study on prospectively collected data of technical complications including 265 adult patients (Regensburg ECMO Registry, 2009-2013) with acute respiratory failure treated with vvECMO. Alterations in blood flow resistance, gas transfer capability, hemolysis, coagulation and hemostasis parameters were evaluated in conjunction with a system-exchange in all patients with at least one exchange (n = 83). Results Values presented as median (interquartile range). Patient age was 50(36–60) years, the SOFA score 11(8–14.3) and the Murray lung injury Score 3.33(3.3–3.7). Cumulative ECMO support time 3411 days, 9(6–15) days per patient. Mechanical failure of the blood pump (n = 5), MO (n = 2) or cannula (n = 1) accounted for 10% of the exchanges. Acute clot formation within the pump head (visible clots, increase in plasma free hemoglobin (frHb), serum lactate dehydrogenase (LDH), n = 13) and MO (increase in pressure drop across the MO, n = 16) required an urgent system-exchange, of which nearly 50% could be foreseen by measuring the parameters mentioned below. Reasons for an elective system-exchange were worsening of gas transfer capability (n = 10) and device-related coagulation disorders (n = 32), either local fibrinolysis in the MO due to clot formation (increased D-dimers [DD]), decreased platelet count; n = 24), or device-induced hyperfibrinolysis (increased DD, decreased fibrinogen [FG], decreased platelet count, diffuse bleeding tendency; n = 8), which could be reversed after system-exchange. Four MOs were exchanged due to suspicion of infection. Conclusions The majority of ECMO system-exchanges could be predicted by regular inspection of the complete ECMO circuit, evaluation of gas exchange, pressure drop across the MO and laboratory parameters (DD, FG, platelets, LDH, frHb). These parameters should be monitored in the daily routine to reduce the risk of unexpected ECMO failure. PMID:25464516
B-1B Avionics/Automatic Test Equipment: Maintenance Queueing Analysis.
1983-12-01
analysis (which is logistics terminology for an avionics/ATE queueing analysis). To allow each vendor the opportunity to perform such an analysis...for system performance measures may be found for the queueing system in Figure 7. This is due to the preemptive blocking caused by ATE failures. The...D-R14l1i75 B-iB AVIONICS/AUTOMPTIC TEST EQUIPMENT: MRINTENRNCE 1/2 QUEUEING RNRLYSIS(U) RIP FORCE INST OF TECH HRIGHT-PRTTERSON RFB OH SCHOOL OF
Obesity and heart failure with preserved ejection fraction: A growing problem.
Prenner, Stuart B; Mather, Paul J
2017-12-14
Heart Failure with Preserved Ejection Fraction (HFpEF) is increasing in prevalence due to the aging of the United States population as well as the current obesity epidemic. While obesity is very common in patients with HFpEF, obesity may represent a specific phenotype of HFpEF characterized by unique hemodynamics and structural abnormalities. Obesity induces a systemic inflammatory response that may contribute to myocardial fibrosis and endothelial dysfunction. The most obese patients continue to be excluded from HFpEF clinical trials, and thus ongoing research is needed to determine the role of pharmacologic and interventional approaches in this growing population. Copyright © 2017 Elsevier Inc. All rights reserved.
Fission product transport analysis in a loss of decay heat removal accident at Browns Ferry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wichner, R.P.; Weber, C.F.; Hodge, S.A.
1984-01-01
This paper summarizes an analysis of the movement of noble gases, iodine, and cesium fission products within the Mark-I containment BWR reactor system represented by Browns Ferry Unit 1 during a postulated accident sequence initiated by a loss of decay heat removal (DHR) capability following a scram. The event analysis showed that this accident could be brought under control by various means, but the sequence with no operator action ultimately leads to containment (drywell) failure followed by loss of water from the reactor vessel, core degradation due to overheating, and reactor vessel failure with attendant movement of core debris ontomore » the drywell floor.« less
Heart failure in South America.
Bocchi, Edimar Alcides
2013-05-01
Continued assessment of temporal trends in mortality and epidemiology of specific heart failure in South America is needed to provide a scientific basis for rational allocation of the limited health care resources, and strategies to reduce risk and predict the future burden of heart failure. The epidemiology of heart failure in South America was reviewed. Heart failure is the main cause of hospitalization based on available data from approximately 50% of the South American population. The main etiologies of heart failure are ischemic, idiopathic dilated cardiomyopathy, valvular, hypertensive and chagasic etiologies. In endemic areas, Chagas heart disease may be responsible by 41% of the HF cases. Also, heart failure presents high mortality especially in patients with Chagas etiology. Heart failure and etiologies associated with heart failure may be responsible for 6.3% of causes of deaths. Rheumatic fever is the leading cause of valvular heart disease. However, a tendency to reduction of HF mortality due to Chagas heart disease from 1985 to 2006, and reduction in mortality due to HF from 1999 to 2005 were observed in selected states in Brazil. The findings have important public health implications because the allocation of health care resources, and strategies to reduce risk of heart failure should also consider the control of neglected Chagas disease and rheumatic fever in South American countries.
Heart Failure in South America
Bocchi, Edimar Alcides
2013-01-01
Continued assessment of temporal trends in mortality and epidemiology of specific heart failure in South America is needed to provide a scientific basis for rational allocation of the limited health care resources, and strategies to reduce risk and predict the future burden of heart failure. The epidemiology of heart failure in South America was reviewed. Heart failure is the main cause of hospitalization based on available data from approximately 50% of the South American population. The main etiologies of heart failure are ischemic, idiopathic dilated cardiomyopathy, valvular, hypertensive and chagasic etiologies. In endemic areas, Chagas heart disease may be responsible by 41% of the HF cases. Also, heart failure presents high mortality especially in patients with Chagas etiology. Heart failure and etiologies associated with heart failure may be responsible for 6.3% of causes of deaths. Rheumatic fever is the leading cause of valvular heart disease. However, a tendency to reduction of HF mortality due to Chagas heart disease from 1985 to 2006, and reduction in mortality due to HF from 1999 to 2005 were observed in selected states in Brazil. The findings have important public health implications because the allocation of health care resources, and strategies to reduce risk of heart failure should also consider the control of neglected Chagas disease and rheumatic fever in South American countries. PMID:23597301
14 CFR 23.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Unsymmetrical loads due to engine failure. 23.367 Section 23.367 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... may be based on the limit pilot forces specified in § 23.397 except that lower forces may be assumed...
14 CFR 25.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Unsymmetrical loads due to engine failure. 25.367 Section 25.367 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... may be based on the control forces specified in § 25.397(b) except that lower forces may be assumed...
14 CFR 25.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Unsymmetrical loads due to engine failure. 25.367 Section 25.367 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... may be based on the control forces specified in § 25.397(b) except that lower forces may be assumed...
14 CFR 23.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Unsymmetrical loads due to engine failure. 23.367 Section 23.367 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... may be based on the limit pilot forces specified in § 23.397 except that lower forces may be assumed...
14 CFR 23.367 - Unsymmetrical loads due to engine failure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Unsymmetrical loads due to engine failure. 23.367 Section 23.367 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... may be based on the limit pilot forces specified in § 23.397 except that lower forces may be assumed...
20 CFR 416.1322 - Suspension due to failure to comply with request for information.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Suspension due to failure to comply with request for information. 416.1322 Section 416.1322 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Suspensions and Terminations § 416.1322...
20 CFR 416.1330 - Suspension due to failure to apply for and obtain other benefits.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Suspension due to failure to apply for and obtain other benefits. 416.1330 Section 416.1330 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Suspensions and Terminations § 416.1330...
New early warning system for gravity-driven ruptures based on codetection of acoustic signal
NASA Astrophysics Data System (ADS)
Faillettaz, J.
2016-12-01
Gravity-driven rupture phenomena in natural media - e.g. landslide, rockfalls, snow or ice avalanches - represent an important class of natural hazards in mountainous regions. To protect the population against such events, a timely evacuation often constitutes the only effective way to secure the potentially endangered area. However, reliable prediction of imminence of such failure events remains challenging due to the nonlinear and complex nature of geological material failure hampered by inherent heterogeneity, unknown initial mechanical state, and complex load application (rainfall, temperature, etc.). Here, a simple method for real-time early warning that considers both the heterogeneity of natural media and characteristics of acoustic emissions attenuation is proposed. This new method capitalizes on codetection of elastic waves emanating from microcracks by multiple and spatially separated sensors. Event-codetection is considered as surrogate for large event size with more frequent codetected events (i.e., detected concurrently on more than one sensor) marking imminence of catastrophic failure. Simple numerical model based on a Fiber Bundle Model considering signal attenuation and hypothetical arrays of sensors confirms the early warning potential of codetection principles. Results suggest that although statistical properties of attenuated signal amplitude could lead to misleading results, monitoring the emergence of large events announcing impeding failure is possible even with attenuated signals depending on sensor network geometry and detection threshold. Preliminary application of the proposed method to acoustic emissions during failure of snow samples has confirmed the potential use of codetection as indicator for imminent failure at lab scale. The applicability of such simple and cheap early warning system is now investigated at a larger scale (hillslope). First results of such a pilot field experiment are presented and analysed.
Research on measurement of aviation magneto ignition strength and balance
NASA Astrophysics Data System (ADS)
Gao, Feng; He, Zhixiang; Zhang, Dingpeng
2017-12-01
Aviation magneto ignition system failure accounted for two-thirds of the total fault aviation piston engine and above. At present the method used for this failure diagnosis is often depended on the visual inspections in the civil aviation maintenance field. Due to human factors, the visual inspections cannot provide ignition intensity value and ignition equilibrium deviation value among the different spark plugs in the different cylinder of aviation piston engine. So air magneto ignition strength and balance testing has become an aviation piston engine maintenance technical problem needed to resolve. In this paper, the ultraviolet sensor with detection wavelength of 185~260nm and driving voltage of 320V DC is used as the core of ultraviolet detection to detect the ignition intensity of Aviation magneto ignition system and the balance deviation of the ignition intensity of each cylinder. The experimental results show that the rotational speed within the range 0 to 3500 RPM test error less than 0.34%, ignition strength analysis and calculation error is less than 0.13%, and measured the visual inspection is hard to distinguish between high voltage wire leakage failure of deviation value of 200 pulse ignition strength balance/Sec. The method to detect aviation piston engine maintenance of magneto ignition system fault has a certain reference value.
[Chronic heart failure and cachexia: role of endocrine system].
Dei Cas, A; Muoio, A; Zavaroni, I
2011-12-01
Chronic heart failure (CHF) is a major health problem that carries a devastating prognosis. The prognosis worsens considerably once cardiac cachexia has been diagnosed. Neurohormonal, metabolic, hemodynamic and immunological alterations are involved in the initiation and progression of cardiac cachexia. Cachexia is characterized by a hypothalamic inappropriate response to the mechanisms controlling energy homeostasis. Levels of the anorexigenic hormone leptin are decreased whereas the orexigenic gherlin hormone levels are normal or elevated. Nevertheless, energy intake is not increased as expected due to a persistent activation of the proopiomelanocortin (POMC) system (anorexigenic) paralleled by a decreased activity of the neuropeptide Y (NPY, orexigenic) neurons. Cachexia is also characterized by an imbalance in anabolic (impairment in the growth hormone/insulin-like growth factor-I axis, insulin resistance) and catabolic (increased levels of catecholamines, increased cortisol/dehydroepiandrosterone ratio and activation of proinflammatory cytokines such as tumor necrosis factor-alpha, interleuchin-6, interleuchin-1') at the basis of the wasting process. This review discusses the complex role of the endocrine system in modulating energy balance, appetite and metabolism in patients with chronic heart failure. A joint multidisciplinary effort of the cardiologists, immunologists and endocrinologists might be useful to identify the precise mechanisms involved in the neuroendocrine alteration and to develop therapeutic strategies able to improve the prognosis of CHF patients.
Retransplant Due to Fulminant Hepatic Failure From Hepatitis E Virus: A Case Report.
Tenorio González, E; Robles Díaz, M; Sanjuan Jiménez, R; González Grande, R; Olmedo Martín, R V; Rodrigo López, J M; Jiménez Pérez, M
2018-03-01
Hepatitis E virus (HEV) usually causes self-limiting acute liver infections from fecal or oral transmission, though other routes of infection exist (vertical transmission, blood transfusion, zoonosis). It may give rise to fulminant hepatic failure in 1% of cases. Cases have recently been reported of chronic infection evolving to cirrhosis in immunosuppressed patients, such as those with a liver or kidney transplant. Nonetheless, development of acute liver failure in these patients is exceptional, with few cases published. We present a case of acute liver failure due to HEV in a liver transplant patient who required a liver retransplant 9 years after receiving the original transplant. Copyright © 2017 Elsevier Inc. All rights reserved.
An elastic failure model of indentation damage. [of brittle structural ceramics
NASA Technical Reports Server (NTRS)
Liaw, B. M.; Kobayashi, A. S.; Emery, A. F.
1984-01-01
A mechanistically consistent model for indentation damage based on elastic failure at tensile or shear overloads, is proposed. The model accommodates arbitrary crack orientation, stress relaxation, reduction and recovery of stiffness due to crack opening and closure, and interfacial friction due to backward sliding of closed cracks. This elastic failure model was implemented by an axisymmetric finite element program which was used to simulate progressive damage in a silicon nitride plate indented by a tungsten carbide sphere. The predicted damage patterns and the permanent impression matched those observed experimentally. The validation of this elastic failure model shows that the plastic deformation postulated by others is not necessary to replicate the indentation damage of brittle structural ceramics.
Complex ruptures during hydraulic fracturing of the Marcellus Shale
NASA Astrophysics Data System (ADS)
Viegas, G. F.; Urbancic, T.; Bosman, K.; Baig, A. M.
2016-12-01
Complex rupture patterns were observed on several M0+ events recorded during a hydraulic stimulation of the Marcellus shale. Although M>0 events associated with hydraulic fracturing have now been commonly recorded and may cause concern in terms of public and infrastructure safety, the vast majority of these events are smaller than M3 and are not felt at the surface. We investigate the rupture characteristics of one such multi-rupture event with 3 sub-events, by examining the failure dynamics of the overall fracture itself and of each individual sub-event, and the growth of the overall fracture from rupture initiation to arrest. This analysis is only possible due to the wide frequency range of the seismic monitoring system put in place which spanned from 0.1 Hz to 1000 Hz. The monitoring system consists of: high-frequency sensor-arrays of geophones deployed downhole close to the reservoir and thus to the rupture initiation point; and low to intermediate frequency accelerometers and geophones deployed at intermediate and shallow depths, allowing for the investigation of overall rupture characteristics. We aim to gain an understanding of the role of asperities, fracture roughness, and fluids on the different aspects of the rupture processes and of the failure mechanisms (shearing versus tensile dominance of behavior) associated with these complex events. Our results show that the overall event is characterized by the failure of multiple asperities and the distance between the 3 sub-events is less than 20 m. We observe decreasing stress drop and increasing Mw over time for the successive sub-events which suggest decreasing frictional resistance due to the presence of fluids over an increasingly large rupture surface akin to increased slip over a larger and less resistant contact area such as an asperity. The overall failure shows a dominant shearing mode mechanism whereas the sub-events failures show strong tensile components. The ruptures of the 1st and 2nd sub-events are indicative of shear-compaction of an asperity and the one of the 3rd sub-event is suggestive of a rupture riding over several surface patches. Additional analysis of other complex events will improve the characterization of the rupture processes of these larger-magnitude events and allow for the assessment of conditions under which the failures occur.
Device monitoring strategies in acute heart failure syndromes.
Samara, Michael A; Tang, W H Wilson
2011-09-01
Acute heart failure syndromes (AHFS) represent the most common discharge diagnoses in adults over age 65 and translate into dramatically increased heart failure-associated morbidity and mortality. Conventional approaches to the early detection of pulmonary and systemic congestion have been shown to be of limited sensitivity. Despite their proven efficacy, disease management and structured telephone support programs have failed to achieve widespread use in part due to their resource intensiveness and reliance upon motivated patients. While once thought to hold great promise, results from recent prospective studies on telemonitoring strategies have proven disappointing. Implantable devices with their capacity to monitor electrophysiologic and hemodynamic parameters over long periods of time and with minimal reliance on patient participation may provide solutions to some of these problems. Conventional electrophysiologic parameters and intrathoracic impedance data are currently available in the growing population of heart failure patients with equipped devices. A variety of implantable hemodynamic monitors are currently under investigation. How best to integrate these devices into a systematic approach to the management of patients before, during, and after AHFS is yet to be established.
Root Cause Failure Analysis of Stator Winding Insulation failure on 6.2 MW hydropower generator
NASA Astrophysics Data System (ADS)
Adhi Nugroho, Agus; Widihastuti, Ida; Ary, As
2017-04-01
Insulation failure on generator winding insulation occurred in the Wonogiri Hydropower plant has caused stator damage since ase was short circuited to ground. The fault has made the generator stop to operate. Wonogiri Hydropower plant is one of the hydroelectric plants run by PT. Indonesia Power UBP Mrica with capacity 2 × 6.2 MW. To prevent damage to occur again on hydropower generators, an analysis is carried out using Root Cause Failure Analysis RCFA is a systematic approach to identify the root cause of the main orbasic root cause of a problem or a condition that is not wanted. There are several aspects to concerned such as: loading pattern and operations, protection systems, generator insulation resistance, vibration, the cleanliness of the air and the ambient air. Insulation damage caused by gradual inhomogeneous cooling at the surface of winding may lead in to partial discharge. In homogeneous cooling may present due to lattice hampered by dust and oil deposits. To avoid repetitive defects and unwanted condition above, it is necessary to perform major maintenance overhaul every 5000-6000 hours of operation.
Machine vision method for online surface inspection of easy open can ends
NASA Astrophysics Data System (ADS)
Mariño, Perfecto; Pastoriza, Vicente; Santamaría, Miguel
2006-10-01
Easy open can end manufacturing process in the food canning sector currently makes use of a manual, non-destructive testing procedure to guarantee can end repair coating quality. This surface inspection is based on a visual inspection made by human inspectors. Due to the high production rate (100 to 500 ends per minute) only a small part of each lot is verified (statistical sampling), then an automatic, online, inspection system, based on machine vision, has been developed to improve this quality control. The inspection system uses a fuzzy model to make the acceptance/rejection decision for each can end from the information obtained by the vision sensor. In this work, the inspection method is presented. This surface inspection system checks the total production, classifies the ends in agreement with an expert human inspector, supplies interpretability to the operators in order to find out the failure causes and reduce mean time to repair during failures, and allows to modify the minimum can end repair coating quality.
NASA Technical Reports Server (NTRS)
Reveley, Mary S.; Briggs, Jeffrey L.; Thomas, Megan A.; Evans, Joni K.; Jones, Sharon M.
2011-01-01
The Integrated Vehicle Health Management (IVHM) Project is one of the four projects within the National Aeronautics and Space Administration's (NASA) Aviation Safety Program (AvSafe). The IVHM Project conducts research to develop validated tools and technologies for automated detection, diagnosis, and prognosis that enable mitigation of adverse events during flight. Adverse events include those that arise from system, subsystem, or component failure, faults, and malfunctions due to damage, degradation, or environmental hazards that occur during flight. Determining the causal factors and adverse events related to IVHM technologies will help in the formulation of research requirements and establish a list of example adverse conditions against which IVHM technologies can be evaluated. This paper documents the results of an examination of the most recent statistical/prognostic accident and incident data that is available from the Aviation Safety Information Analysis and Sharing (ASIAS) System to determine the causal factors of system/component failures and/or malfunctions in U.S. commercial aviation accidents and incidents.
Totally implantable system for peritoneal access.
Pfeifle, C E; Howell, S B; Markman, M; Lucas, W E
1984-11-01
A totally implantable system for providing access to the peritoneal cavity was evaluated. Fifty-six Port-A-Cath (Pharmacia Nu Tech, Piscataway, NJ) peritoneal access systems were implanted in 54 cancer patients receiving intraperitoneal chemotherapy. The catheters are accessed by transcutaneous placement of a Huber point needle through a silicone septum at the top of the portal. A total of 32 patient years of experience are reported. The Port-A-Caths have been in place for a median of 22 weeks (range, one to 85). A total of 401 entries have been made for paracentesis, chemotherapy administration, antibiotic administration, peritoneal lavage for cytology, and catheter flushing. There have been six episodes of peritonitis (five Staphylococcus epidermidis, one S aureus) in three patients. There have been no mechanical failures of the Port-A-Caths. Loss of bidirectional flow through the catheter due to fibrin deposition about the catheter has been the major cause of catheter failure. Patient acceptance of the Port-A-Cath has been excellent.
Li, Lei; He, Qingming; Wei, Yunmei; He, Qin; Peng, Xuya
2014-11-01
To determine reliable state parameters which could be used as early warning indicators of process failure due to the acidification of anaerobic digestion of food waste, three mesophilic anaerobic digesters of food waste with different operation conditions were investigated. Such parameters as gas production, methane content, pH, concentrations of volatile fatty acid (VFA), alkalinity and their combined indicators were evaluated. Results revealed that operation conditions significantly affect the responses of parameters and thus the optimal early warning indicators of each reactor differ from each other. None of the single indicators was universally valid for all the systems. The universally valid indicators should combine several parameters to supply complementary information. A combination of total VFA, the ratio of VFA to total alkalinity (VFA/TA) and the ratio of bicarbonate alkalinity to total alkalinity (BA/TA) can reflect the metabolism of the digesting system and realize rapid and effective early warning. Copyright © 2014 Elsevier Ltd. All rights reserved.
Modeling the roles of damage accumulation and mechanical healing on rainfall-induced landslides
NASA Astrophysics Data System (ADS)
Fan, Linfeng; Lehmann, Peter; Or, Dani
2014-05-01
The abrupt release of rainfall-induced shallow landslides is preceded by local failures that may abruptly coalesce and form a continuous failure plane within a hillslope. The mechanical status of hillslopes reflects a competition between the extent of severity of accumulated local damage during prior rainfall events and the rates of mechanically healing (i.e. regaining of strength) by closure of micro-cracks, regrowth of roots, etc. The interplay of these processes affects the initial conditions for landslide modeling and shapes potential failure patterns during future rainfall events. We incorporated these competing mechanical processes in a hydro-mechanical landslide triggering model subjected to a sequence of rainfall scenarios. The model employs the Fiber Bundle Model (FBM) with bonds (fiber bundle) with prescribed threshold linking adjacent soil columns and soil to bedrock. Prior damage was represented by a fraction of broken fibers during previous rainfall events, and the healing of broken fibers was described by strength regaining models for soil and roots at different characteristic time scales. Results show that prior damage and healing introduce highly nonlinear response to landslide triggering. For small prior damage, mechanical bonds at soil-bedrock interface may fail early in next rainfall event but lead to small perturbations onto lateral bonds without triggering a landslide. For more severe damage weakening lateral bonds, excess load due to failure at soil-bedrock interface accumulates at downslope soil columns resulting in early soil failure with patterns strongly correlated with prior damage distribution. Increasing prior damage over the hillslope decreases the volume of first landslide and prolongs the time needed to trigger the second landslide due to mechanical relaxation of the system. The mechanical healing of fibers diminishes effects of prior damage on the time of failure, and shortens waiting time between the first and second landslides. These findings highlight the need to improve definition of initial conditions and the shortcomings of assuming pristine hillslopes.
Bucindolol: A Pharmacogenomic Perspective on Its Use in Chronic Heart Failure
Smart, Neil A.; Kwok, Nigel; Holland, David J.; Jayasighe, Rohan; Giallauria, Francesco
2011-01-01
Bucindolol is a non-selective β-adrenergic receptor blocker with α-1 blocker properties and mild intrinsic sympatholytic activity. The Beta-Blocker Evaluation of Survival Trial (BEST), which is the largest clinical trial of bucindolol in patients with heart failure, was terminated prematurely and failed to show an overall mortality benefit. However, benefits on cardiac mortality and re-hospitalization rates were observed in the BEST trial. Bucindolol has not shown benefits in African Americans, those with significantly low ejection fraction and those in NYHA class IV heart failure. These observations could be due to the exaggerated sympatholytic response to bucindolol in these sub-groups that may be mediated by genetic polymorphisms or changes in gene regulation due to advanced heart failure. This paper provides a timely clinical update on the use of bucindolol in chronic heart failure. PMID:21792345
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Oberkampf, William Louis; Helton, Jon Craig
2004-12-01
Relationships to determine the probability that a weak link (WL)/strong link (SL) safety system will fail to function as intended in a fire environment are investigated. In the systems under study, failure of the WL system before failure of the SL system is intended to render the overall system inoperational and thus prevent the possible occurrence of accidents with potentially serious consequences. Formal developments of the probability that the WL system fails to deactivate the overall system before failure of the SL system (i.e., the probability of loss of assured safety, PLOAS) are presented for several WWSL configurations: (i) onemore » WL, one SL, (ii) multiple WLs, multiple SLs with failure of any SL before any WL constituting failure of the safety system, (iii) multiple WLs, multiple SLs with failure of all SLs before any WL constituting failure of the safety system, and (iv) multiple WLs, multiple SLs and multiple sublinks in each SL with failure of any sublink constituting failure of the associated SL and failure of all SLs before failure of any WL constituting failure of the safety system. The indicated probabilities derive from time-dependent temperatures in the WL/SL system and variability (i.e., aleatory uncertainty) in the temperatures at which the individual components of this system fail and are formally defined as multidimensional integrals. Numerical procedures based on quadrature (i.e., trapezoidal rule, Simpson's rule) and also on Monte Carlo techniques (i.e., simple random sampling, importance sampling) are described and illustrated for the evaluation of these integrals. Example uncertainty and sensitivity analyses for PLOAS involving the representation of uncertainty (i.e., epistemic uncertainty) with probability theory and also with evidence theory are presented.« less
Goldsmith, Steven R; Bart, Bradley A; Pin A, Ileana L
2017-12-16
Decompensated or acute heart failure (AHF) is characterized by increased ventricular and atrial pressures which may lead to and be caused by circulatory congestion. Unless due to a primary decrease in cardiac function, congestion arises from volume expansion or vasoconstriction. In turn, volume expansion and vasoconstriction are due to neurohormonal imbalance since both result from activation of the sympathetic nervous system, the renin-angiotensin-aldosterone axis and excess secretion of arginine vasopressin. Outcomes in AHF remain dismal. Loop diuretics are the mainstay of therapy for AHF and may themselves aggravate neurohormonal imbalance. No adjunctive pharmacotherapy has yielded improvement in outcomes in AHF despite many attempts with various vasodilators and inotropes. We, therefore, propose that insufficient attention has been paid to neurohormonal imbalance in AHF. As in chronic HF, rectifying the effects of neurohormonal imbalance may lead to better outcomes. The use of alternative decongestive strategies or adjunctive pharmacotherapy directed at neurohormonal activation could yield benefit. Copyright © 2017 Elsevier B.V. All rights reserved.
Heroic Reliability Improvement in Manned Space Systems
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
System reliability can be significantly improved by a strong continued effort to identify and remove all the causes of actual failures. Newly designed systems often have unexpected high failure rates which can be reduced by successive design improvements until the final operational system has an acceptable failure rate. There are many causes of failures and many ways to remove them. New systems may have poor specifications, design errors, or mistaken operations concepts. Correcting unexpected problems as they occur can produce large early gains in reliability. Improved technology in materials, components, and design approaches can increase reliability. The reliability growth is achieved by repeatedly operating the system until it fails, identifying the failure cause, and fixing the problem. The failure rate reduction that can be obtained depends on the number and the failure rates of the correctable failures. Under the strong assumption that the failure causes can be removed, the decline in overall failure rate can be predicted. If a failure occurs at the rate of lambda per unit time, the expected time before the failure occurs and can be corrected is 1/lambda, the Mean Time Before Failure (MTBF). Finding and fixing a less frequent failure with the rate of lambda/2 per unit time requires twice as long, time of 1/(2 lambda). Cutting the failure rate in half requires doubling the test and redesign time and finding and eliminating the failure causes.Reducing the failure rate significantly requires a heroic reliability improvement effort.
NASA Astrophysics Data System (ADS)
Rahman, Abdul Ghaffar Abdul; Noroozi, Siamak; Dupac, Mihai; Mahathir Syed Mohd Al-Attas, Syed; Vinney, John E.
2013-03-01
Complex rotating machinery requires regular condition monitoring inspections to assess their running conditions and their structural integrity to prevent catastrophic failures. Machine failures can be divided into two categories. First is the wear and tear during operation, they range from bearing defects, gear damage, misalignment, imbalance or mechanical looseness, for which simple condition-based maintenance techniques can easily detect the root cause and trigger remedial action process. The second factor in machine failure is caused by the inherent design faults that usually happened due to many reasons such as improper installation, poor servicing, bad workmanship and structural dynamics design deficiency. In fact, individual machines components are generally dynamically well designed and rigorously tested. However, when these machines are assembled on sight and linked together, their dynamic characteristics will change causing unexpected behaviour of the system. Since nondestructive evaluation provides an excellent alternative to the classical monitoring and proved attractive due to the possibility of performing reliable assessments of all types of machinery, the novel dynamic design verification procedure - based on the combination of in-service operation deflection shape measurement, experimental modal analysis and iterative inverse finite element analysis - proposed here allows quick identification of structural weakness, and helps to provide and verify the solutions.
Utilization of artificial intelligence techniques for the Space Station power system
NASA Technical Reports Server (NTRS)
Evatt, Thomas C.; Gholdston, Edward W.
1988-01-01
Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.
Stetson, Peter D.; McKnight, Lawrence K.; Bakken, Suzanne; Curran, Christine; Kubose, Tate T.; Cimino, James J.
2002-01-01
Medical errors are common, costly and often preventable. Work in understanding the proximal causes of medical errors demonstrates that systems failures predispose to adverse clinical events. Most of these systems failures are due to lack of appropriate information at the appropriate time during the course of clinical care. Problems with clinical communication are common proximal causes of medical errors. We have begun a project designed to measure the impact of wireless computing on medical errors. We report here on our efforts to develop an ontology representing the intersection of medical errors, information needs and the communication space. We will use this ontology to support the collection, storage and interpretation of project data. The ontology’s formal representation of the concepts in this novel domain will help guide the rational deployment of our informatics interventions. A real-life scenario is evaluated using the ontology in order to demonstrate its utility.
[Thoracic aortic dissection revealed by systemic cholesterol embolism].
Braem, L; Paule, P; Héno, P; Morand, J J; Mafart, B; La Folie, T; Varlet, P; Mioulet, D; Fourcade, L
2006-10-01
Systemic cholesterol embolism is a rare complication of atherosclerosis, and has various presentations. Arterial catheterisms are a common cause. However, the association with an aortic dissection has been exceptionally reported. We report the observation of a 70 year-old man, with coronary artery disease, hypertension, diabetes and dyslipidemia. Six months before hospitalization, a coronary angioplasty was performed due to recurrent angina. The association of purpuric lesions on the feet, with acute renal failure confirmed cholesterol embolism syndrome. Transoesophageal echocardiography showed a dissection of the descending thoracic aorta associated with complex atheroma. The evolution was marked by the pulpar necrosis of a toe and by a worsening of the renal failure, requiring definitive hemodialysis. Further echographic control highlighted the rupture of the intimal veil of the dissection. Cholesterol embolism syndrome may reveal an aortic dissection in patients without thoracic symptoms. In such cases, transoesophageal echocardiography is a useful and non-invasive examination.
Park, Seong C; Finnell, John T
2012-01-01
In 2009, Indianapolis launched an electronic medical record system within their ambulances1 and started to exchange patient data with the Indiana Network for Patient Care (INPC) This unique system allows EMS personnel to get important information prior to the patient's arrival to the hospital. In this descriptive study, we found EMS personnel requested patient data on 14% of all transports, with a "success" match rate of 46%, and a match "failure" rate of 17%. The three major factors for causing match "failure" were ZIP code 55%, Patient Name 22%, and Birth date 12%. We conclude that the ZIP code matching process needs to be improved by applying a limitation of 5 digits in ZIP code instead of using ZIP+4 code. Non-ZIP code identifiers may be a better choice due to inaccuracies and changes of the ZIP code in a patient's record.
NASA Astrophysics Data System (ADS)
Fremlin, Carl; Beckers, Jasper; Crowley, Brendan; Rauch, Joseph; Scoville, Jim
2017-10-01
The Neutral Beam system on the DIII-D tokamak consists of eight ion sources using the Common Long Pulse Source (CLPS) design. During helium operation, desired for research regarding the ITER pre-nuclear phase, it has been observed that the ion source arc chamber performance steadily deteriorates, eventually failing due to electrical breakdown of the insulation. A significant investment of manpower and time is required for repairs. To study the cause of failure a small analogue of the DIII-D neutral beam arc chamber has been constructed. This poster presents the design and analysis of the arc chamber including the PLC based operational control system for the experiment, analysis of the magnetic confinement and details of the diagnostic suite. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698.
NASA Technical Reports Server (NTRS)
Zhu, Dong-Ming; Choi, Sung R.; Eldridge, Jeffrey I.; Lee, Kang N.; Miller, Robert A.
2003-01-01
In this paper, surface cracking and interface reactions of a BSAS coating and a multi-layer ZrO2-8wt%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic tests in a water vapor containing environment. The surface cracking was analyzed based on the coating thermal gradient sintering behavior and thermal expansion mismatch stress characteristics under the thermal cyclic conditions. The interface reactions, which were largely enhanced by the coating surface cracking in the water vapor environment, were investigated in detail, and the reaction phases were identified for the coating system after the long-term exposure. The accelerated coating delamination failure was attributed to the increased delamination driving force under the thermal gradient cyclic loading and the reduced interface adhesion due to the detrimental interface reactions.
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Choi, Sung R.; Eldridge, Jeffrey I.; Lee, Kang N.; Miller, Robert A.
2003-01-01
In this paper, surface cracking and interface reactions of a BSAS coating and a multi-layer ZTO2-8wt%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic tests in a water vapor containing environment. The surface cracking was analyzed based on the coating thermal gradient sintering behavior and thermal expansion mismatch stress characteristics under the thermal cyclic conditions. The interface reactions, which were largely enhanced by the coating surface cracking in the water vapor environment, were investigated in detail, and the reaction phases were identified for the coating system after the long- term exposure. The accelerated coating delamination failure was attributed to the increased delamination driving force under the thermal gradient cyclic loading and the reduced interface adhesion due to the detrimental interface reactions.
Nonlinear structural crack growth monitoring
Welch, Donald E.; Hively, Lee M.; Holdaway, Ray F.
2002-01-01
A method and apparatus are provided for the detection, through nonlinear manipulation of data, of an indicator of imminent failure due to crack growth in structural elements. The method is a process of determining energy consumption due to crack growth and correlating the energy consumption with physical phenomena indicative of a failure event. The apparatus includes sensors for sensing physical data factors, processors or the like for computing a relationship between the physical data factors and phenomena indicative of the failure event, and apparatus for providing notification of the characteristics and extent of such phenomena.
Percolation of a general network of networks.
Gao, Jianxi; Buldyrev, Sergey V; Stanley, H Eugene; Xu, Xiaoming; Havlin, Shlomo
2013-12-01
Percolation theory is an approach to study the vulnerability of a system. We develop an analytical framework and analyze the percolation properties of a network composed of interdependent networks (NetONet). Typically, percolation of a single network shows that the damage in the network due to a failure is a continuous function of the size of the failure, i.e., the fraction of failed nodes. In sharp contrast, in NetONet, due to the cascading failures, the percolation transition may be discontinuous and even a single node failure may lead to an abrupt collapse of the system. We demonstrate our general framework for a NetONet composed of n classic Erdős-Rényi (ER) networks, where each network depends on the same number m of other networks, i.e., for a random regular network (RR) formed of interdependent ER networks. The dependency between nodes of different networks is taken as one-to-one correspondence, i.e., a node in one network can depend only on one node in the other network (no-feedback condition). In contrast to a treelike NetONet in which the size of the largest connected cluster (mutual component) depends on n, the loops in the RR NetONet cause the largest connected cluster to depend only on m and the topology of each network but not on n. We also analyzed the extremely vulnerable feedback condition of coupling, where the coupling between nodes of different networks is not one-to-one correspondence. In the case of NetONet formed of ER networks, percolation only exhibits two phases, a second order phase transition and collapse, and no first order percolation transition regime is found in the case of the no-feedback condition. In the case of NetONet composed of RR networks, there exists a first order phase transition when the coupling strength q (fraction of interdependency links) is large and a second order phase transition when q is small. Our insight on the resilience of coupled networks might help in designing robust interdependent systems.
Failure mechanism of hollow tree trunks due to cross-sectional flattening
Huang, Yan-San; Hsu, Fu-Lan; Lee, Chin-Mei
2017-01-01
Failure of hollow trees in urban areas is a worldwide concern, and it can be caused by different mechanisms, i.e. bending stresses or flattening-related failures. Here we derive a new analytical expression for predicting the bending moment for tangential cracking, and compare the breaking moment of various failure modes, including Brazier buckling, tangential cracking, shear failure and conventional bending failure, as a function of t/R ratio, where t and R are the trunk wall thickness and trunk radius, respectively, of a hollow tree. We use Taiwan red cypress as an example and show that its failure modes and the corresponding t/R ratios are: Brazier buckling (Mode I), tangential cracking followed by longitudinal splitting (Mode II) and conventional bending failure (Mode III) for 0 < t/R < 0.06, 0.06 < t/R < 0.27 and 0.27 < t/R < 1, respectively. The exact values of those ratios may vary within and among species, but the variation is much smaller than individual mechanical properties. Also, shear failure, another type of cracking due to maximum shear stress near the neutral axis of the tree trunk, is unlikely to occur since it requires much larger bending moments. Hence, we conclude that tangential cracking due to cross-sectional flattening, followed by longitudinal splitting, is dominant for hollow trunks. Our equations are applicable to analyse straight hollow tree trunks and plant stems, but are not applicable to those with side openings or those with only heart decay. Our findings provide insights for those managing trees in urban situations and those managing for conservation of hollow-dependent fauna in both urban and rural settings. PMID:28484616
NASA Technical Reports Server (NTRS)
Leimkuehler, Thomas O.; Hansen, Scott; Stephan, Ryan A.
2009-01-01
Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM s have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation.
NASA Technical Reports Server (NTRS)
Leimkuehler, Thomas O.; Hansen, Scott; Stephan, Ryan A.
2010-01-01
Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM's have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation. Nomenclature
Steenholdt, Casper; Coskun, Mehmet; Buhl, Sine; Bendtzen, Klaus; Ainsworth, Mark A; Brynskov, Jørn; Nielsen, Ole H
2016-04-01
The inflammatory response at infliximab (IFX) treatment failure due to tumor necrosis factor (TNF)-α-independent Crohn disease activity is unknown. This is an exploratory, hypothesis-generating study based on samples collected in a clinical trial among patients failing conventional IFX dosages and treated with an intensified IFX regimen for 12 weeks. Patients with clinical response at week 12, as defined by a reduction of Crohn disease activity index by ≥70, were considered to suffer from nonimmune pharmacokinetic (PK) treatment failure (n = 18), and nonresponders had a presumed pharmacodynamic (PD) failure due to non-TNF-driven disease (n = 8). Patients failing IFX due to functional anti-IFX antibodies (n = 2) were excluded. The study population also comprised a group of 12 patients in long-term remission on IFX. A functional cell-based reporter gene assay was applied to measure IFX and anti-IFX antibodies. Circulating cytokines and cytokine receptors were assessed by enzyme-linked immunosorbent assay: granulocyte-macrophage colony-stimulating factor, interferon-γ, interleukin (IL)-1α, IL-1β, IL-1Ra, IL-6, IL-10, IL-12p70, soluble TNF receptor (sTNF-R) 1, sTNF-R2, IL-17A, and monocyte chemotactic protein 1. The IFX levels were similar between patients with IFX failure caused by nonimmune PK or PD at treatment failure (median 1.4 vs 2.4 μg/mL; P = 0.52), during treatment intensification (8.1 vs 5.6; P = 0.85), and after 12 weeks (8.8 vs 7.7; P = 0.93), congruent with nonresponders failing IFX due to predominantly TNF-α-independent signaling pathways in their disease. Cytokine and cytokine receptor levels were comparable between patients with nonimmune PK failure and PD failure at time of manifestation of IFX failure, but with higher IL-6 and sTNF-R2 levels among IFX treatment failures as compared with patients in remission (IL-6 median 3.6 vs <3.1 pg/mL; P = 0.03; sTNF-R2 3207 vs 2547 pg/mL; P = 0.01). IL-6 and sTNF-R2 were lower after 12 weeks in nonimmune PK failures than in PD failures (<3.1 vs 4.0; P = 0.02; 3209 vs 4740; P = 0.04, respectively), and were measured at levels comparable with patients in remission. Further, trends of decreased IL-6 and sTNF-R2 levels among nonimmune PK failures during IFX intensification (P < 0.05 and P = 0.12) were observed. These observations indicate that IL-6 and sTNF-R2 are of potential relevance in driving the inflammatory response in IFX refractory Crohn disease caused by TNF-α-independent disease activity.
Steenholdt, Casper; Coskun, Mehmet; Buhl, Sine; Bendtzen, Klaus; Ainsworth, Mark A.; Brynskov, Jørn; Nielsen, Ole H.
2016-01-01
Abstract The inflammatory response at infliximab (IFX) treatment failure due to tumor necrosis factor (TNF)-α-independent Crohn disease activity is unknown. This is an exploratory, hypothesis-generating study based on samples collected in a clinical trial among patients failing conventional IFX dosages and treated with an intensified IFX regimen for 12 weeks. Patients with clinical response at week 12, as defined by a reduction of Crohn disease activity index by ≥70, were considered to suffer from nonimmune pharmacokinetic (PK) treatment failure (n = 18), and nonresponders had a presumed pharmacodynamic (PD) failure due to non-TNF-driven disease (n = 8). Patients failing IFX due to functional anti-IFX antibodies (n = 2) were excluded. The study population also comprised a group of 12 patients in long-term remission on IFX. A functional cell-based reporter gene assay was applied to measure IFX and anti-IFX antibodies. Circulating cytokines and cytokine receptors were assessed by enzyme-linked immunosorbent assay: granulocyte-macrophage colony-stimulating factor, interferon-γ, interleukin (IL)-1α, IL-1β, IL-1Ra, IL-6, IL-10, IL-12p70, soluble TNF receptor (sTNF-R) 1, sTNF-R2, IL-17A, and monocyte chemotactic protein 1. The IFX levels were similar between patients with IFX failure caused by nonimmune PK or PD at treatment failure (median 1.4 vs 2.4 μg/mL; P = 0.52), during treatment intensification (8.1 vs 5.6; P = 0.85), and after 12 weeks (8.8 vs 7.7; P = 0.93), congruent with nonresponders failing IFX due to predominantly TNF-α-independent signaling pathways in their disease. Cytokine and cytokine receptor levels were comparable between patients with nonimmune PK failure and PD failure at time of manifestation of IFX failure, but with higher IL-6 and sTNF-R2 levels among IFX treatment failures as compared with patients in remission (IL-6 median 3.6 vs <3.1 pg/mL; P = 0.03; sTNF-R2 3207 vs 2547 pg/mL; P = 0.01). IL-6 and sTNF-R2 were lower after 12 weeks in nonimmune PK failures than in PD failures (<3.1 vs 4.0; P = 0.02; 3209 vs 4740; P = 0.04, respectively), and were measured at levels comparable with patients in remission. Further, trends of decreased IL-6 and sTNF-R2 levels among nonimmune PK failures during IFX intensification (P < 0.05 and P = 0.12) were observed. These observations indicate that IL-6 and sTNF-R2 are of potential relevance in driving the inflammatory response in IFX refractory Crohn disease caused by TNF-α-independent disease activity. PMID:27100432
Probability of loss of assured safety in systems with multiple time-dependent failure modes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helton, Jon Craig; Pilch, Martin.; Sallaberry, Cedric Jean-Marie.
2012-09-01
Weak link (WL)/strong link (SL) systems are important parts of the overall operational design of high-consequence systems. In such designs, the SL system is very robust and is intended to permit operation of the entire system under, and only under, intended conditions. In contrast, the WL system is intended to fail in a predictable and irreversible manner under accident conditions and render the entire system inoperable before an accidental operation of the SL system. The likelihood that the WL system will fail to deactivate the entire system before the SL system fails (i.e., degrades into a configuration that could allowmore » an accidental operation of the entire system) is referred to as probability of loss of assured safety (PLOAS). Representations for PLOAS for situations in which both link physical properties and link failure properties are time-dependent are derived and numerically evaluated for a variety of WL/SL configurations, including PLOAS defined by (i) failure of all SLs before failure of any WL, (ii) failure of any SL before failure of any WL, (iii) failure of all SLs before failure of all WLs, and (iv) failure of any SL before failure of all WLs. The effects of aleatory uncertainty and epistemic uncertainty in the definition and numerical evaluation of PLOAS are considered.« less
Rodrigues, Samantha A; Thambyah, Ashvin; Broom, Neil D
2015-03-01
The annulus-endplate anchorage system performs a critical role in the disc, creating a strong structural link between the compliant annulus and the rigid vertebrae. Endplate failure is thought to be associated with disc herniation, a recent study indicating that this failure mode occurs more frequently than annular rupture. The aim was to investigate the structural principles governing annulus-endplate anchorage and the basis of its strength and mechanisms of failure. Loading experiments were performed on ovine lumbar motion segments designed to induce annulus-endplate failure, followed by macro- to micro- to fibril-level structural analyses. The study was funded by a doctoral scholarship from our institution. Samples were loaded to failure in three modes: torsion using intact motion segments, in-plane tension of the anterior annulus-endplate along one of the oblique fiber angles, and axial tension of the anterior annulus-endplate. The anterior region was chosen for its ease of access. Decalcification was used to investigate the mechanical influence of the mineralized component. Structural analysis was conducted on both the intact and failed samples using differential interference contrast optical microscopy and scanning electron microscopy. Two main modes of anchorage failure were observed--failure at the tidemark or at the cement line. Samples subjected to axial tension contained more tidemark failures compared with those subjected to torsion and in-plane tension. Samples decalcified before testing frequently contained damage at the cement line, this being more extensive than in fresh samples. Analysis of the intact samples at their anchorage sites revealed that annular subbundle fibrils penetrate beyond the cement line to a limited depth and appear to merge with those in the vertebral and cartilaginous endplates. Annulus-endplate anchorage is more vulnerable to failure in axial tension compared with both torsion and in-plane tension and is probably due to acute fiber bending at the soft-hard interface of the tidemark. This finding is consistent with evidence showing that flexion, which induces a similar pattern of axial tension, increases the risk of herniation involving endplate failure. The study also highlights the important strengthening role of calcification at this junction and provides new evidence of a fibril-based form of structural integration across the cement line. Copyright © 2015 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Espinoza, Kelly Etcheberry
2016-01-01
Strong communication skills are essential in establishing a foundation for safe delivery of care. A report from the Institute of Medicine (IOM) titled: "To Err is Human: Building a Safer Health System" estimated 44,000 to 98,000 deaths occur due to medical errors annually. Communication failure was found to be the root cause in 70% of…
The Tunable XUV Imager (TXI) Sounding Rocket Payload
NASA Technical Reports Server (NTRS)
Brinton, John (Technical Monitor); Golub, Leon
2004-01-01
The TXI was flown successfully on 21 June 2001 (36.199 US). All systems functioned as planned and image data were acquired and sent to the ground. Unfortunately, due to a parachute failure the payload was destroyed. In this report we summarize results from the flight and provide detailed information on the high resolution X-ray imaging detector which was developed as part of the program.
Risk Based Reliability Centered Maintenance of DOD Fire Protection Systems
1999-01-01
2.2.3 Failure Mode and Effect Analysis ( FMEA )............................ 2.2.4 Failure Mode Risk Characterization...Step 2 - System functions and functional failures definition Step 3 - Failure mode and effect analysis ( FMEA ) Step 4 - Failure mode risk...system). The Interface Location column identifies the location where the FMEA of the fire protection system began or stopped. For example, for the fire
Three-point bending of honeycomb sandwich beams with facesheet perforations
NASA Astrophysics Data System (ADS)
Su, Pengbo; Han, Bin; Zhao, Zhongnan; Zhang, Qiancheng; Lu, Tian Jian
2017-12-01
A novel square honeycomb-cored sandwich beam with perforated bottom facesheet is investigated under three-point bending, both analytically and numerically. Perforated square holes in the bottom facesheet are characterized by the area ratio of the hole to intact facesheet (perforation ratio). While for large-scale engineering applications like the decks of cargo vehicles and transportation ships, the perforations are needed to facilitate the fabrication process (e.g., laser welding) as well as service maintenance, it is demonstrated that these perforations, when properly designed, can also enhance the resistance of the sandwich to bending. For illustration, fair comparisons among competing sandwich designs having different perforation ratios but equal mass is achieved by systematically thickening the core webs. Further, the perforated sandwich beam is designed with a relatively thick facesheet to avoid local indention failure so that it mainly fails in two competing modes: (1) bending failure, i.e., yielding of beam cross-section and buckling of top facesheet caused by bending moment; (2) shear failure, i.e., yielding and buckling of core webs due to shear forcing. The sensitivity of the failure loads to the ratio of core height to beam span is also discussed for varying perforation ratios. As the perforation ratio is increased, the load of shear failure increases due to thickening core webs, while that of bending failure decreases due to the weakening bottom facesheet. Design of a sandwich beam with optimal perforation ratio is realized when the two failure loads are equal, leading to significantly enhanced failure load (up to 60% increase) relative to that of a non-perforated sandwich beam with equal mass.
27 CFR 70.103 - Failure to pay tax.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2013-04-01 2013-04-01 false Failure to pay tax. 70.103... § 70.103 Failure to pay tax. Whoever fails to pay any tax imposed by Part I of Subchapter A of Chapter... penalty of 5 percent of the tax due but unpaid. For additional penalties for failure to pay tax, see 27...
27 CFR 70.103 - Failure to pay tax.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2014-04-01 2014-04-01 false Failure to pay tax. 70.103... § 70.103 Failure to pay tax. Whoever fails to pay any tax imposed by Part I of Subchapter A of Chapter... penalty of 5 percent of the tax due but unpaid. For additional penalties for failure to pay tax, see 27...
27 CFR 70.103 - Failure to pay tax.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2012-04-01 2011-04-01 true Failure to pay tax. 70.103... § 70.103 Failure to pay tax. Whoever fails to pay any tax imposed by Part I of Subchapter A of Chapter... penalty of 5 percent of the tax due but unpaid. For additional penalties for failure to pay tax, see 27...
27 CFR 70.103 - Failure to pay tax.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2011-04-01 2011-04-01 false Failure to pay tax. 70.103... § 70.103 Failure to pay tax. Whoever fails to pay any tax imposed by Part I of Subchapter A of Chapter... penalty of 5 percent of the tax due but unpaid. For additional penalties for failure to pay tax, see 27...
27 CFR 70.103 - Failure to pay tax.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Failure to pay tax. 70.103... § 70.103 Failure to pay tax. Whoever fails to pay any tax imposed by Part I of Subchapter A of Chapter... penalty of 5 percent of the tax due but unpaid. For additional penalties for failure to pay tax, see 27...
NASA Technical Reports Server (NTRS)
McCarty, John P.; Lyles, Garry M.
1997-01-01
Propulsion system quality is defined in this paper as having high reliability, that is, quality is a high probability of within-tolerance performance or operation. Since failures are out-of-tolerance performance, the probability of failures and their occurrence is the difference between high and low quality systems. Failures can be described at 3 levels: the system failure (which is the detectable end of a failure), the failure mode (which is the failure process), and the failure cause (which is the start). Failure causes can be evaluated & classified by type. The results of typing flight history failures shows that most failures are in unrecognized modes and result from human error or noise, i.e. failures are when engineers learn how things really work. Although the study based on US launch vehicles, a sampling of failures from other countries indicates the finding has broad application. The parameters of the design of a propulsion system are not single valued, but have dispersions associated with the manufacturing of parts. Many tests are needed to find failures, if the dispersions are large relative to tolerances, which could contribute to the large number of failures in unrecognized modes.
Diagnosis and management of heart failure in the elderly.
King, D
1996-10-01
Heart failure is common in the elderly and is associated with a significant morbidity and mortality. It accounts for about 5% of adult medical admissions and the expenditure of 1% of the total National Health Service budget. Clinical presentation in old age may be with the classical symptoms of heart failure but often, due to multiple pathology and low functional ability, presentation is atypical. Both nonspecific symptoms and signs of heart failure, are often a delayed presentation in this population, make diagnosis difficult. Treatment of the failing heart in an older person is similar to the young however, diligence is required when prescribing due to age-related pharmacokinetic changes and co-existent morbidity. This may result in polypharmacy and an increase in drug interactions which themselves may have deleterious consequences. However, knowledge of the aetiology of heart failure in old age and the possible atypical presentation as well as available treatments, will result in better management and improved quality of life and reduced mortality in the elderly heart failure population.
Diagnosis and management of heart failure in the elderly.
King, D.
1996-01-01
Heart failure is common in the elderly and is associated with a significant morbidity and mortality. It accounts for about 5% of adult medical admissions and the expenditure of 1% of the total National Health Service budget. Clinical presentation in old age may be with the classical symptoms of heart failure but often, due to multiple pathology and low functional ability, presentation is atypical. Both nonspecific symptoms and signs of heart failure, are often a delayed presentation in this population, make diagnosis difficult. Treatment of the failing heart in an older person is similar to the young however, diligence is required when prescribing due to age-related pharmacokinetic changes and co-existent morbidity. This may result in polypharmacy and an increase in drug interactions which themselves may have deleterious consequences. However, knowledge of the aetiology of heart failure in old age and the possible atypical presentation as well as available treatments, will result in better management and improved quality of life and reduced mortality in the elderly heart failure population. PMID:8977936
USAF Evaluation of an Automated Adaptive Flight Training System
1975-10-01
system. C. What is the most effective wav to utilize the system in ^jierational training’ Student opinion for this question JS equally divided...None Utility hydraulic failure Flap failure left engine failure Right engine failure Stah 2 aug failure No g\\ ro approach procedure, no MIDI
DOE Office of Scientific and Technical Information (OSTI.GOV)
L. Arena
High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window andmore » door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.« less
Reliability-based management of buried pipelines considering external corrosion defects
NASA Astrophysics Data System (ADS)
Miran, Seyedeh Azadeh
Corrosion is one of the main deteriorating mechanisms that degrade the energy pipeline integrity, due to transferring corrosive fluid or gas and interacting with corrosive environment. Corrosion defects are usually detected by periodical inspections using in-line inspection (ILI) methods. In order to ensure pipeline safety, this study develops a cost-effective maintenance strategy that consists of three aspects: corrosion growth model development using ILI data, time-dependent performance evaluation, and optimal inspection interval determination. In particular, the proposed study is applied to a cathodic protected buried steel pipeline located in Mexico. First, time-dependent power-law formulation is adopted to probabilistically characterize growth of the maximum depth and length of the external corrosion defects. Dependency between defect depth and length are considered in the model development and generation of the corrosion defects over time is characterized by the homogenous Poisson process. The growth models unknown parameters are evaluated based on the ILI data through the Bayesian updating method with Markov Chain Monte Carlo (MCMC) simulation technique. The proposed corrosion growth models can be used when either matched or non-matched defects are available, and have ability to consider newly generated defects since last inspection. Results of this part of study show that both depth and length growth models can predict damage quantities reasonably well and a strong correlation between defect depth and length is found. Next, time-dependent system failure probabilities are evaluated using developed corrosion growth models considering prevailing uncertainties where three failure modes, namely small leak, large leak and rupture are considered. Performance of the pipeline is evaluated through failure probability per km (or called a sub-system) where each subsystem is considered as a series system of detected and newly generated defects within that sub-system. Sensitivity analysis is also performed to determine to which incorporated parameter(s) in the growth models reliability of the studied pipeline is most sensitive. The reliability analysis results suggest that newly generated defects should be considered in calculating failure probability, especially for prediction of long-term performance of the pipeline and also, impact of the statistical uncertainty in the model parameters is significant that should be considered in the reliability analysis. Finally, with the evaluated time-dependent failure probabilities, a life cycle-cost analysis is conducted to determine optimal inspection interval of studied pipeline. The expected total life-cycle costs consists construction cost and expected costs of inspections, repair, and failure. The repair is conducted when failure probability from any described failure mode exceeds pre-defined probability threshold after each inspection. Moreover, this study also investigates impact of repair threshold values and unit costs of inspection and failure on the expected total life-cycle cost and optimal inspection interval through a parametric study. The analysis suggests that a smaller inspection interval leads to higher inspection costs, but can lower failure cost and also repair cost is less significant compared to inspection and failure costs.
NASA Astrophysics Data System (ADS)
Nebashi, Ryusuke; Sakimura, Noboru; Sugibayashi, Tadahiko
2017-08-01
We evaluated the soft-error tolerance and energy consumption of an embedded computer with magnetic random access memory (MRAM) using two computer simulators. One is a central processing unit (CPU) simulator of a typical embedded computer system. We simulated the radiation-induced single-event-upset (SEU) probability in a spin-transfer-torque MRAM cell and also the failure rate of a typical embedded computer due to its main memory SEU error. The other is a delay tolerant network (DTN) system simulator. It simulates the power dissipation of wireless sensor network nodes of the system using a revised CPU simulator and a network simulator. We demonstrated that the SEU effect on the embedded computer with 1 Gbit MRAM-based working memory is less than 1 failure in time (FIT). We also demonstrated that the energy consumption of the DTN sensor node with MRAM-based working memory can be reduced to 1/11. These results indicate that MRAM-based working memory enhances the disaster tolerance of embedded computers.
[Primary systemic amyloidosis].
Tanasilović, Srdan; Zivanović, Dubravka; Nikolić, Milos; Tomović, Maja; Elezović, Ivo; Medenica, Ljiljana
2007-12-01
Systemic amyloidosis is a rare disorder which usually occurs in aged persons and has a poor prognosis. Systemic amyloidosis can be primary, occasionally associated with multiple myeloma, or secondary, associated with another disease. We presented a 72-year-old male patient with periocular purpura ("racoon sign") and waxy papules, petechiae and ecchymoses on the neck and thoracic area. Purpuric macules were present also on the lips and tongue which was edematous (macroglossia). The skin lesions occurred two years earlier, the patient lost more than 15 kilograms of the body mass for less than a year. Immunoelectrophoresis of urine and serum demonstrated the presence of immunoglobulin light chains of the circulating monoclonal protein. Histopathological examination of skin lesions showed Congo red positive deposits in the derm. Cardiac evaluation revealed the signs of heart failure, and renal evaluation revealed nephrotic syndrome, with excessive protein lost. He was treated with oral melphalan and prednisolone, and died 7 days after starting the therapy due to heart failure. This patient considered as a rare case with systemic amyloidosis highlights the importance of histopathological and physical examination in any cases with periocular purpura, petechiae, ecchymoses and macroglossia.
Cost-of-illness studies in heart failure: a systematic review 2004-2016.
Lesyuk, Wladimir; Kriza, Christine; Kolominsky-Rabas, Peter
2018-05-02
Heart failure is a major and growing medical and economic problem worldwide as 1-2% of the healthcare budget are spent for heart failure. The prevalence of heart failure has increased over the past decades and it is expected that there will be further raise due to the higher proportion of elderly in the western societies. In this context cost-of-illness studies can significantly contribute to a better understanding of the drivers and problems which lead to the increasing costs in heart failure. The aim of this study was to perform a systematic review of published cost-of-illness studies related to heart failure to highlight the increasing cost impact of heart failure. A systematic review was conducted from 2004 to 2016 to identify cost-of-illness studies related to heart failure, searching PubMed (Medline), Cochrane, Science Direct (Embase), Scopus and CRD York Database. Of the total of 16 studies identified, 11 studies reported prevalence-based estimates, 2 studies focused on incidence-based data and 3 articles presented both types of cost data. A large variation concerning cost components and estimates can be noted. Only three studies estimated indirect costs. Most of the included studies have shown that the costs for hospital admission are the most expensive cost element. Estimates for annual prevalence-based costs for heart failure patients range from $868 for South Korea to $25,532 for Germany. The lifetime costs for heart failure patients have been estimated to $126.819 per patient. Our review highlights the considerable and growing economic burden of heart failure on the health care systems. The cost-of-illness studies included in this review show large variations in methodology used and the cost results vary consequently. High quality data from cost-of-illness studies with a robust methodology applied can inform policy makers about the major cost drivers of heart failure and can be used as the basis of further economic evaluations.
Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Burchfield, David E.; Trubey, Richard; Denson, Steve; Tissandier, Amber; Gentry, Greg; Granahan, John; Matty, Chris
2011-01-01
The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. It is an integral part of the Environmental Control and Life Support System (ECLSS). The MCA system is comprised of seven orbit-replaceable units (ORUs) that provide flexibility in maintaining the MCA. Of these, ORU 02, the analyzer assembly requires replacement every 1 to 2 years due to the consumption of limited life components including the ion pump and ion source filaments. Typically, ORU 02s that reach end of life are swapped out of the MCA on orbit and replaced with the on-orbit spare. The replaced ORU 02 is then returned to the OEM for refurbishment and is then return to service. Recently, 2 refurbished ORU 02s, serial numbers F0001 and F0003, failed on orbit shortly after being installed into the MCA. Both ORU 02s have been returned to ground for TT&E, and a failure investigation is underway. The failure signatures have been reproduced on the ground and an initial investigation has determined that both ORU 02 failures involve either the ion source or the ion source control electronics. This paper discusses the results of the failure investigation, the steps required to refurbish the ORU 02s, and the risk mitigation steps that are being incorporated into the refurbishment process to preclude the reoccurrence of these failures in the future
Wireless sensing and vibration control with increased redundancy and robustness design.
Li, Peng; Li, Luyu; Song, Gangbing; Yu, Yan
2014-11-01
Control systems with long distance sensor and actuator wiring have the problem of high system cost and increased sensor noise. Wireless sensor network (WSN)-based control systems are an alternative solution involving lower setup and maintenance costs and reduced sensor noise. However, WSN-based control systems also encounter problems such as possible data loss, irregular sampling periods (due to the uncertainty of the wireless channel), and the possibility of sensor breakdown (due to the increased complexity of the overall control system). In this paper, a wireless microcontroller-based control system is designed and implemented to wirelessly perform vibration control. The wireless microcontroller-based system is quite different from regular control systems due to its limited speed and computational power. Hardware, software, and control algorithm design are described in detail to demonstrate this prototype. Model and system state compensation is used in the wireless control system to solve the problems of data loss and sensor breakdown. A positive position feedback controller is used as the control law for the task of active vibration suppression. Both wired and wireless controllers are implemented. The results show that the WSN-based control system can be successfully used to suppress the vibration and produces resilient results in the presence of sensor failure.
The economics (or lack thereof) of aerosol geoengineering
NASA Astrophysics Data System (ADS)
Goes, M.; Keller, K.; Tuana, N.
2009-04-01
Anthropogenic greenhouse gas emissions are changing the Earth's climate and impose substantial risks for current and future generations. What are scientifically sound, economically viable, and ethically defendable strategies to manage these climate risks? Ratified international agreements call for a reduction of greenhouse gas emissions to avoid dangerous anthropogenic interference with the climate system. Recent proposals, however, call for the deployment of a different approach: to geoengineer climate by injecting aerosol precursors into the stratosphere. Published economic studies typically suggest that substituting aerosol geoengineering for abatement of carbon dioxide emissions results in large net monetary benefits. However, these studies neglect the risks of aerosol geoengineering due to (i) the potential for future geoengineering failures and (ii) the negative impacts associated with the aerosol forcing. Here we use a simple integrated assessment model of climate change to analyze potential economic impacts of aerosol geoengineering strategies over a wide range of uncertain parameters such as climate sensitivity, the economic damages due to climate change, and the economic damages due to aerosol geoengineering forcing. The simplicity of the model provides the advantages of parsimony and transparency, but it also imposes severe caveats on the interpretation of the results. For example, the analysis is based on a globally aggregated model and is hence silent on the question of intragenerational distribution of costs and benefits. In addition, the analysis neglects the effects of endogenous learning about the climate system. We show that the risks associated with a future geoengineering failure and negative impacts of aerosol forcings can cause geoenginering strategies to fail an economic cost-benefit test. One key to this finding is that a geoengineering failure would lead to dramatic and abrupt climatic changes. The monetary damages due to this failure can dominate the cost-benefit analysis because the monetary damages of climate change are expected to increase with the rate of change. Substituting aerosol geoengineering for greenhouse gas emission abatement might fail not only an economic cost-benefit test but also an ethical test of distributional justice. Substituting aerosol geoengineering for greenhouse gas emissions abatements constitutes a conscious risk transfer to future generations. Intergenerational justice demands distributional justice, namely that present generations may not create benefits for themselves in exchange for burdens on future generations. We use the economic model to quantify this risk transfer to better inform the judgment of whether substituting aerosol geoengineering for carbon dioxide emission abatement fails this ethical test.
Degradation and ESR Failures in MnO2 Chip Tantalum Capacitors
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander A.
2017-01-01
Equivalent series resistance (ESR) of chip tantalum capacitors determines the rate of energy delivery and power dissipation thus affecting temperature and reliability of the parts. Employment of advanced capacitors with reduced ESR decreases power losses and improves efficiency in power systems. Stability of ESR is essential for correct operations of power units and might cause malfunctioning and failures when ESR becomes too high or too low. Several cases with ESR values in CWR29 capacitors exceeding the specified limit that were observed recently raised concerns regarding environmental factors affecting ESR and the adequacy of the existing screening and qualification testing. In this work, results of stress testing of various types of military and commercial capacitors obtained over years by GSFC test lab and NEPP projects that involved ESR measurements are described. Environmental stress tests include testing in humidity and vacuum chambers, temperature cycling, long-term storage at high temperatures, and various soldering simulation tests. Note that in many cases parts failed due to excessive leakage currents or reduced breakdown voltages. However, only ESR-related degradation and failures are discussed. Mechanisms of moisture effect are discussed and recommendations to improve screening and qualification system are suggested.
NASALIFE - Component Fatigue and Creep Life Prediction Program
NASA Technical Reports Server (NTRS)
Gyekenyesi, John Z.; Murthy, Pappu L. N.; Mital, Subodh K.
2014-01-01
NASALIFE is a life prediction program for propulsion system components made of ceramic matrix composites (CMC) under cyclic thermo-mechanical loading and creep rupture conditions. Although the primary focus was for CMC components, the underlying methodologies are equally applicable to other material systems as well. The program references empirical data for low cycle fatigue (LCF), creep rupture, and static material properties as part of the life prediction process. Multiaxial stresses are accommodated by Von Mises based methods and a Walker model is used to address mean stress effects. Varying loads are reduced by the Rainflow counting method or a peak counting type method. Lastly, damage due to cyclic loading and creep is combined with Minor's Rule to determine damage due to cyclic loading, damage due to creep, and the total damage per mission and the number of potential missions the component can provide before failure.
Operation of U.S. Geological Survey unmanned digital magnetic observatories
Wilson, L.R.
1990-01-01
The precision and continuity of data recorded by unmanned digital magnetic observatories depend on the type of data acquisition equipment used and operating procedures employed. Three generations of observatory systems used by the U.S. Geological Survey are described. A table listing the frequency of component failures in the current observatory system has been compiled for a 54-month period of operation. The cause of component failure was generally mechanical or due to lightning. The average percentage data loss per month for 13 observatories operating a combined total of 637 months was 9%. Frequency distributions of data loss intervals show the highest frequency of occurrence to be intervals of less than 1 h. Installation of the third generation system will begin in 1988. The configuration of the third generation observatory system will eliminate most of the mechanical problems, and its components should be less susceptible to lightning. A quasi-absolute coil-proton system will be added to obtain baseline control for component variation data twice daily. Observatory data, diagnostics, and magnetic activity indices will be collected at 12-min intervals via satellite at Golden, Colorado. An improvement in the quality and continuity of data obtained with the new system is expected. ?? 1990.
Nonlinear temperature dependent failure analysis of finite width composite laminates
NASA Technical Reports Server (NTRS)
Nagarkar, A. P.; Herakovich, C. T.
1979-01-01
A quasi-three dimensional, nonlinear elastic finite element stress analysis of finite width composite laminates including curing stresses is presented. Cross-ply, angle-ply, and two quasi-isotropic graphite/epoxy laminates are studied. Curing stresses are calculated using temperature dependent elastic properties that are input as percent retention curves, and stresses due to mechanical loading in the form of an axial strain are calculated using tangent modulii obtained by Ramberg-Osgood parameters. It is shown that curing stresses and stresses due to tensile loading are significant as edge effects in all types of laminate studies. The tensor polynomial failure criterion is used to predict the initiation of failure. The mode of failure is predicted by examining individual stress contributions to the tensor polynomial.
NASA Astrophysics Data System (ADS)
ChePa, Noraziah; Jasin, Noorhayati Md; Bakar, Nur Azzah Abu
2017-10-01
Fail to prevent or control challenges of Information System (IS) implementation have led to the failure of its implementation. Successful implementation of IS has been a challenging task to any organization including government hospitals. Government has invested a big amount of money on information system (IS) projects to improve service delivery in healthcare. However, several of them failed to be implemented successfully due to several factors. This article proposes a prevention model which incorporated Change Management (CM) concepts to avoid the failure of IS implementation, hence ensuring the success of it. Challenges of IS implementation in government hospitals have been discovered. Extensive literature review and deep interview approaches were employed to discover these challenges. A prevention model has been designed to cater the challenges. The model caters three main phases of implementation; pre-implementation, during implementation, and post-implementation by adopting CM practices of Lewin's, Kotter's and Prosci's CM model. Six elements of CM comprising thirteen sub-elements adopted from the three CM models have been used to handle CFFs of Human and Support issues; guiding team, resistance avoidance, IS adoption, enforcement, monitoring, and IS sustainability. Successful practice of the proposed mapping is expected to prevent CFFs to occur, hence ensuring a successful implementation of IS in the hospitals. The proposed model has been presented and successfully evaluated by the domain experts from the selected hospitals. The proposed model is believed to be beneficial for top management, IT practitioners and medical practitioners in preventing IS implementation failure among government hospitals towards ensuring the success implementation.
Doval, H C; Nul, D R; Grancelli, H O; Perrone, S V; Bortman, G R; Curiel, R
1994-08-20
In severe heart failure many deaths are sudden and are presumed to be due to ventricular arrhythmias. The GESICA trial evaluated the effect of low-dose amiodarone on two-year mortality in patients with severe heart failure. Our prospective multicentre trial included 516 patients on optimal standard treatment for heart failure. Patients were randomised to 300 mg/day amiodarone (260) or to standard treatment (256). Intention-to-treat analysis showed 87 deaths in the amiodarone group (33.5%) compared with 106 in the control group (41.4%) (risk reduction 28%; 95% CI 4%-45%; log rank test p = 0.024). There were reductions in both sudden death (risk reduction 27%; p = 0.16) and death due to progressive heart failure (risk reduction 23%; p = 0.16). Fewer patients in the amiodarone group died or were admitted to hospital due to worsening heart failure (119 versus 149 in the control group; risk reduction 31%; 95% CI 13-46%; p = 0.0024). The decrease in mortality and hospital admission was present in all subgroups examined and independent of the presence of non-sustained ventricular tachycardia. Side-effects were reported in 17 patients (6.1%); amiodarone was withdrawn in 12. Low-dose amiodarone proved to be an effective and reliable treatment, reducing mortality and hospital admission in patients with severe heart failure independently of the presence of complex ventricular arrhythmias.
Magnezi, Racheli; Hemi, Asaf; Hemi, Rina
2016-01-01
Background Risk management in health care systems applies to all hospital employees and directors as they deal with human life and emergency routines. There is a constant need to decrease risk and increase patient safety in the hospital environment. The purpose of this article is to review the laboratory testing procedures for parathyroid hormone and adrenocorticotropic hormone (which are characterized by short half-lives) and to track failure modes and risks, and offer solutions to prevent them. During a routine quality improvement review at the Endocrine Laboratory in Tel Hashomer Hospital, we discovered these tests are frequently repeated unnecessarily due to multiple failures. The repetition of the tests inconveniences patients and leads to extra work for the laboratory and logistics personnel as well as the nurses and doctors who have to perform many tasks with limited resources. Methods A team of eight staff members accompanied by the Head of the Endocrine Laboratory formed the team for analysis. The failure mode and effects analysis model (FMEA) was used to analyze the laboratory testing procedure and was designed to simplify the process steps and indicate and rank possible failures. Results A total of 23 failure modes were found within the process, 19 of which were ranked by level of severity. The FMEA model prioritizes failures by their risk priority number (RPN). For example, the most serious failure was the delay after the samples were collected from the department (RPN =226.1). Conclusion This model helped us to visualize the process in a simple way. After analyzing the information, solutions were proposed to prevent failures, and a method to completely avoid the top four problems was also developed. PMID:27980440
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sallaberry, Cedric Jean-Marie.; Helton, Jon Craig
2012-10-01
Weak link (WL)/strong link (SL) systems are important parts of the overall operational design of high-consequence systems. In such designs, the SL system is very robust and is intended to permit operation of the entire system under, and only under, intended conditions. In contrast, the WL system is intended to fail in a predictable and irreversible manner under accident conditions and render the entire system inoperable before an accidental operation of the SL system. The likelihood that the WL system will fail to deactivate the entire system before the SL system fails (i.e., degrades into a configuration that could allowmore » an accidental operation of the entire system) is referred to as probability of loss of assured safety (PLOAS). This report describes the Fortran 90 program CPLOAS_2 that implements the following representations for PLOAS for situations in which both link physical properties and link failure properties are time-dependent: (i) failure of all SLs before failure of any WL, (ii) failure of any SL before failure of any WL, (iii) failure of all SLs before failure of all WLs, and (iv) failure of any SL before failure of all WLs. The effects of aleatory uncertainty and epistemic uncertainty in the definition and numerical evaluation of PLOAS can be included in the calculations performed by CPLOAS_2.« less
Clinical features of multiple organ failure in the elderly.
Wang, S W; Fan, L
1990-09-01
Multiple organ failure (MOF) in the elderly is a new syndrome evolved from multiple organ chronic diseases on the basis of multiple organ dysfunction in the aged. Its characteristics are clinically different from those of MOF due to serious trauma. 122 cases of MOF were analysed retrospectively and their clinical features discussed. MOF with a long course is the natural presentation in many of the elderly before death. Its main precipitating factors are pulmonary infection, metastatic carcinoma, cardiac attack, etc. The sequence of a failure in organs is heart, lung, kidney, liver, etc. The mortality is similar to that of MOF due to trauma. However, those suffering from 4-organ failure can still survive, and instead, the renal failure can be mostly fatal. More attention should be paid to the prevention of MOF in the elderly so as to shorten its developing course.
Program Helps In Analysis Of Failures
NASA Technical Reports Server (NTRS)
Stevenson, R. W.; Austin, M. E.; Miller, J. G.
1993-01-01
Failure Environment Analysis Tool (FEAT) computer program developed to enable people to see and better understand effects of failures in system. User selects failures from either engineering schematic diagrams or digraph-model graphics, and effects or potential causes of failures highlighted in color on same schematic-diagram or digraph representation. Uses digraph models to answer two questions: What will happen to system if set of failure events occurs? and What are possible causes of set of selected failures? Helps design reviewers understand exactly what redundancies built into system and where there is need to protect weak parts of system or remove them by redesign. Program also useful in operations, where it helps identify causes of failure after they occur. FEAT reduces costs of evaluation of designs, training, and learning how failures propagate through system. Written using Macintosh Programmers Workshop C v3.1. Can be linked with CLIPS 5.0 (MSC-21927, available from COSMIC).
NASA Technical Reports Server (NTRS)
Weiss, Jerold L.; Hsu, John Y.
1986-01-01
The use of a decentralized approach to failure detection and isolation for use in restructurable control systems is examined. This work has produced: (1) A method for evaluating fundamental limits to FDI performance; (2) Application using flight recorded data; (3) A working control element FDI system with maximal sensitivity to critical control element failures; (4) Extensive testing on realistic simulations; and (5) A detailed design methodology involving parameter optimization (with respect to model uncertainties) and sensitivity analyses. This project has concentrated on detection and isolation of generic control element failures since these failures frequently lead to emergency conditions and since knowledge of remaining control authority is essential for control system redesign. The failures are generic in the sense that no temporal failure signature information was assumed. Thus, various forms of functional failures are treated in a unified fashion. Such a treatment results in a robust FDI system (i.e., one that covers all failure modes) but sacrifices some performance when detailed failure signature information is known, useful, and employed properly. It was assumed throughout that all sensors are validated (i.e., contain only in-spec errors) and that only the first failure of a single control element needs to be detected and isolated. The FDI system which has been developed will handle a class of multiple failures.
1991-09-01
Army (i #Awleable) Engineer istrict. Walls Welli NPW-EN- GI _____________________ Bc DRSSW4~Sse.adZPa 10 SOURCE OF FUNDING NUMBERS Bldg. 602, City...cracks induced by ground motions. Z. Overtopping of dam due to seiches in reservoir. h. Overtopping of dam due to slides or rockfalls into reservoir. j...overtopping due to slides or rockfalls is not likely. Three potential modes of failure remain from the original list: (c) slope failures induced by
Schoonmaker, A.; Kidd, W.S.F.; Bradley, D.C.
2005-01-01
During collisional convergence, failure in extension of the lithosphere of the lower plate due to slab pull will reduce the thickness or completely remove lower-plate lithosphere and cause decompression melting of the asthenospheric mantle; magmas from this source may subsequently provide enough heat for substantial partial melting of crustal rocks under or beyond the toe of the collisional accretionary system. In central Maine, United States, this type of magmatism is first apparent in the Early Devonian West Branch Volcanics and equivalent mafic volcanics, in the slightly younger voluminous mafic/silicic magmatic event of the Moxie Gabbro-Katahdin batholith and related ignimbrite volcanism, and in other Early Devonian granitic plutons. Similar lower-plate collisional sequences with mafic and related silicic magmatism probably caused by slab breakoff are seen in the Miocene-Holocene Papuan orogen, and the Hercynian-Alleghenian belt. Magmatism of this type is significant because it gives evidence in those examples of whole-lithosphere extension. We infer that normal fault systems in outer trench slopes of collisional orogens in general, and possibly those of oceanic subduction zones, may not be primarily due to flexural bending, but are also driven by whole-lithosphere extension due to slab pull. The Maine Acadian example suggests that slab failure and this type of magmatism may be promoted by pre-existing large margin-parallel faults in the lower plate. ?? 2005 Geological Society of America.
NASA Technical Reports Server (NTRS)
Swanson, Theodore
2008-01-01
The focus of this chapter is on the long term wear and tear, or aging, of the mechanical subsystem of a spacecraft. The mechanical subsystem is herein considered to be the primary support structure (as in a skeleton or exoskeleton) upon which all other spacecraft systems rest, and the associated mechanisms. Mechanisms are devices which have some component that moves at least once, in response to some type of passive or active control system. For the structure, aging may proceed as a gradual degradation of mechanical properties and/or function, possibly leading to complete structural failure over an extended period of time. However, over the 50 years of the Space Age such failures appear to be unusual. In contrast, failures for mechanisms are much more frequent and may have a very serious effect on mission performance. Just as on Earth, all moving devices are subject to normal (and possibly accelerated) degradation from mechanical wear due to loss or breakdown of lubricant, misalignment, temperature cycling effects, improper design/selection of materials, fatigue, and a variety of other effects. In space, such environmental factors as severe temperature swings (possibly 100's of degrees C while going in and out of direct solar exposure), hard vacuum, micrometeoroids, wear from operation in a dusty or contaminated environment, and materials degradation from radiation can be much worse. In addition, there are some ground handling issues such as humidity, long term storage, and ground transport which may be of concern. This chapter addresses the elements of the mechanical subsystem subject to wear, and identifies possible causes. The potential impact of such degradation is addressed, albeit with the recognition that the impact of such wear often depends on when it occurs and on what specific components. Most structural elements of the mechanical system typically are conservatively designed (often to a safety factor of greater than approximately 1.25 on yield for unmanned spacecraft) but do not have backup structure due to the added mass this would impose, and also due to the fact that structural elements can be accurately modeled mathematically and in test. Critical mechanisms or devices may have backups, or alternate work-arounds, since characterization of these systems in a 1g environment is less accurate than structure, and repair in-space is often impossible.
Failure detection system risk reduction assessment
NASA Technical Reports Server (NTRS)
Aguilar, Robert B. (Inventor); Huang, Zhaofeng (Inventor)
2012-01-01
A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.
[A case of Crow-Fukase syndrome with respiratory failure due to bilateral diaphragmatic paralysis].
Namekawa, Michito; Muramatsu, Shin-ichi; Hashimoto, Ritsuo; Kawakami, Tadataka; Fujimoto, Ken-ichi; Nakano, Imaharu
2002-07-01
A 62-year-old man with well-controlled diabetes mellitus developed numbness of the bilateral feet and hands, followed by subacutely progressive weakness and amyotrophy of extremities. He became bed-ridden state, and dyspnea also appeared, so he was referred to our hospital. Physical examination revealed a lean man, with dark-reddish skin pigmentation, crabbed fingers, bilateral pretibial pitting edema, and bristles in extremities. Thoracoabdominal paradoxical respiration was observed and pulmonary vesicular sounds was decreased markedly in the both lungs. Laboratory data revealed hypoproteinemia, abnormalities of endocrine system, but M-protein was not detected. Serum vascular endothelial growth factor level was quite high. Chest radiography revealed elevation of the bilateral diaphragm, the % vital capacity (%VC) was 24%, and arterial blood gas analysis showed marked hypoxia with hypercapnia. These findings suggested that his respiratory failure was induced by bilateral diaphragmatic paralysis caused by bilateral phrenic nerve palsy due to Crow-Fukase syndrome. He became somnolent because of hypercapnic narcosis, so non-invasive positive pressure ventilation (NIPPV) was started. We treated him with intravenous immunoglobulin and oral corticosteroids therapies, and after these therapies, his symptoms were remarkably recovered and NIPPV became unnecessary soon. The most frequent causes of respiratory failure in Crow-Fukase syndrome are pleural effusion and pulmonary hypertension, and only two cases of this syndrome with respiratory failure caused by bilateral diaphragmatic paralysis were reported until now. When the patients with Crow-Fukase syndrome complain of dyspnea, we should take the diaphragmatic paralysis into consideration, which may be improved by appropriate therapies.
Intermittent output failure of a VVI device due to the disintegration of the generator.
Böhm, A; Kayser, S; Pintér, A; Préda, I
2001-01-01
The metal case and the header of a Biovallees Coralite 247 pacemaker fell apart in a patient resulting in syncope due to myopotential inhibition. Upon recalling our patients with that type of device, we found a similar technological failure in 11 of 16 of them. This finding warrants a consideration for recalling that Biovallees device.
Cyber-Threat Assessment for the Air Traffic Management System: A Network Controls Approach
NASA Technical Reports Server (NTRS)
Roy, Sandip; Sridhar, Banavar
2016-01-01
Air transportation networks are being disrupted with increasing frequency by failures in their cyber- (computing, communication, control) systems. Whether these cyber- failures arise due to deliberate attacks or incidental errors, they can have far-reaching impact on the performance of the air traffic control and management systems. For instance, a computer failure in the Washington DC Air Route Traffic Control Center (ZDC) on August 15, 2015, caused nearly complete closure of the Centers airspace for several hours. This closure had a propagative impact across the United States National Airspace System, causing changed congestion patterns and requiring placement of a suite of traffic management initiatives to address the capacity reduction and congestion. A snapshot of traffic on that day clearly shows the closure of the ZDC airspace and the resulting congestion at its boundary, which required augmented traffic management at multiple locations. Cyber- events also have important ramifications for private stakeholders, particularly the airlines. During the last few months, computer-system issues have caused several airlines fleets to be grounded for significant periods of time: these include United Airlines (twice), LOT Polish Airlines, and American Airlines. Delays and regional stoppages due to cyber- events are even more common, and may have myriad causes (e.g., failure of the Department of Homeland Security systems needed for security check of passengers, see [3]). The growing frequency of cyber- disruptions in the air transportation system reflects a much broader trend in the modern society: cyber- failures and threats are becoming increasingly pervasive, varied, and impactful. In consequence, an intense effort is underway to develop secure and resilient cyber- systems that can protect against, detect, and remove threats, see e.g. and its many citations. The outcomes of this wide effort on cyber- security are applicable to the air transportation infrastructure, and indeed security solutions are being implemented in the current system. While these security solutions are important, they only provide a piecemeal solution. Particular computers or communication channels are protected from particular attacks, without a holistic view of the air transportation infrastructure. On the other hand, the above-listed incidents highlight that a holistic approach is needed, for several reasons. First, the air transportation infrastructure is a large scale cyber-physical system with multiple stakeholders and diverse legacy assets. It is impractical to protect every cyber- asset from known and unknown disruptions, and instead a strategic view of security is needed. Second, disruptions to the cyber- system can incur complex propagative impacts across the air transportation network, including its physical and human assets. Also, these implications of cyber- events are exacerbated or modulated by other disruptions and operational specifics, e.g. severe weather, operator fatigue or error, etc. These characteristics motivate a holistic and strategic perspective on protecting the air transportation infrastructure from cyber- events. The analysis of cyber- threats to the air traffic system is also inextricably tied to the integration of new autonomy into the airspace. The replacement of human operators with cyber functions leaves the network open to new cyber threats, which must be modeled and managed. Paradoxically, the mitigation of cyber events in the airspace will also likely require additional autonomy, given the fast time scale and myriad pathways of cyber-attacks which must be managed. The assessment of new vulnerabilities upon integration of new autonomy is also a key motivation for a holistic perspective on cyber threats.
Intelligent systems for strategic power infrastructure defense
NASA Astrophysics Data System (ADS)
Jung, Ju-Hwan
A fault or disturbance in a power system can be severe due to the sources of vulnerability such as human errors, protection and control system failures, a failure of communication networks to deliver critical control signals, and market and load uncertainties. There have been several catastrophic failures resulting from disturbances involving the sources of vulnerability while power systems are designed to withstand disturbances or faults. To avoid catastrophic failures or minimize the impact of a disturbance(s), the state of the power system has to be analyzed correctly and preventive or corrective self-healing control actions have to be deployed. This dissertation addresses two aspects of power systems: Defense system and diagnosis, both concerned with the power system analysis and operation during events involving faults or disturbances. This study is intended to develop a defense system that is able to assess power system vulnerability and to perform self-healing control actions based on the system-wide analysis. In order to meet the requirements of the system-wide analysis, the defense system is designed with multi-agent system technologies. Since power systems are dynamic and uncertain the self-healing control actions need to be adaptive. This study applies the reinforcement learning technique to provide a theoretical basis for adaptation. One of the important issues in adaptation is the convergence of the learning algorithm. An appropriate convergence criterion is derived and an application with a load-shedding scheme is demonstrated in this study. This dissertation also demonstrates the feasibility of the defense system and self-healing control actions through multi-agent system technologies. The other subject of this research is to investigate the methodology for on-line fault diagnosis using the information from Sequence-of-Events Recorders (SER). The proposed multiple-hypothesis analysis generates one or more hypothetical fault scenarios to interpret the SER information. In order to avoid ambiguity of the hypotheses, this study proposes a new method to determine the credibility of each hypothesis. Even if there is not enough SER information, the proposed method is able to perform an accurate fault and malfunction analysis. To avoid exhaustive testing, a minimal set of test scenarios is derived, which is able to handle missing information and SERs. During extreme contingencies or cascading events, fault diagnosis is the first step in the operation of the power system. On-line fault diagnosis provides necessary and correct information for the defense system to make correct and efficient decisions on self-healing control actions. It has been shown in previous studies that incorrect fault diagnosis can lead to catastrophic failures in power systems. Fault diagnosis is an important issue for strategic power infrastructure defense.
Impoundment of the Zipingpu reservoir and triggering of the 2008 Mw 7.9 Wenchuan earthquake, China
Tao, Wei; Masterlark, Timothy; Ronchin, Erika
2015-01-01
Abstract Impoundment of the Zipingpu reservoir (ZR), China, began in September 2005 and was followed 2.7 years later by the 2008 Mw 7.9 Wenchuan earthquake (WE) rupturing the Longmen Shan Fault (LSF), with its epicenter ~12 km away from the ZR. Based on the poroelastic theory, we employ three‐dimensional finite element models to simulate the evolution of stress and pore pressure due to reservoir impoundment, and its effect on the Coulomb failure stress on the LSF. The results indicate that the reservoir impoundment formed a pore pressure front that slowly propagated through the crust with fluid diffusion. The reservoir loading induced either moderate or no increase of the Coulomb failure stress at the hypocenter prior to the WE. The Coulomb failure stress, however, grew ~9.3–69.1 kPa in the depth range of 1–8 km on the LSF, which may have advanced tectonic loading of the fault system by ~60–450 years. Due to uncertainties of fault geometry and hypocenter location of the WE, it is inconclusive whether impoundment of the ZR directly triggered the WE. However, a small event at the hypocenter could have triggered large rupture elsewhere on fault, where the asperities were weakened by the ZR. The microseismicity around the ZR also showed an expanding pattern from the ZR since its impoundment, likely associated with diffusion of a positive pore pressure pulse. These results suggest a poroelastic triggering effect (even if indirectly) of the WE due to the impoundment of the ZR. PMID:27812436
20 CFR 416.728 - Penalty period: Second failure to report.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Penalty period: Second failure to report. 416.728 Section 416.728 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME... penalty period. The due date and the failure to report on time are the important factors in establishing a...
Acute respiratory failure due to thyroid storm developing immediately after delivery.
Kitazawa, Chie; Aoki, Shigeru; Takahashi, Tsuneo; Hirahara, Fumiki
2015-12-01
Acute respiratory failure occurs in less than 0.1% of pregnancies. Thyroid storm should be included in the differential diagnosis of possible causes of acute respiratory failure occurring immediately after delivery, and delivery is a high risk factor for thyroid storm in pregnant women with thyrotoxicosis.
Towards designing robust coupled networks
NASA Astrophysics Data System (ADS)
Schneider, Christian M.; Yazdani, Nuri; Araújo, Nuno A. M.; Havlin, Shlomo; Herrmann, Hans J.
2013-06-01
Natural and technological interdependent systems have been shown to be highly vulnerable due to cascading failures and an abrupt collapse of global connectivity under initial failure. Mitigating the risk by partial disconnection endangers their functionality. Here we propose a systematic strategy of selecting a minimum number of autonomous nodes that guarantee a smooth transition in robustness. Our method which is based on betweenness is tested on various examples including the famous 2003 electrical blackout of Italy. We show that, with this strategy, the necessary number of autonomous nodes can be reduced by a factor of five compared to a random choice. We also find that the transition to abrupt collapse follows tricritical scaling characterized by a set of exponents which is independent on the protection strategy.
Solder Reflow Failures in Electronic Components During Manual Soldering
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander; Greenwell, Chris; Felt, Frederick
2008-01-01
This viewgraph presentation reviews the solder reflow failures in electronic components that occur during manual soldering. It discusses the specifics of manual-soldering-induced failures in plastic devices with internal solder joints. The failure analysis turned up that molten solder had squeezed up to the die surface along the die molding compound interface, and the dice were not protected with glassivation allowing solder to short gate and source to the drain contact. The failure analysis concluded that the parts failed due to overheating during manual soldering.
NASA Technical Reports Server (NTRS)
Jegley, Dawn C.
1989-01-01
The multi-span-beam shear test procedure is used to study failure mechanisms in graphite-epoxy laminates due to high transverse shear strains induced by severe local bending deformations in test specimens. Results of a series of tests on specimens with a variety of stacking sequences, including some with adhesive interleaving, are presented. These results indicate that laminates with stacking sequences with several + or - 45 and 90 deg plies next to each other are more susceptible to failures due to high transverse shear strains than laminates with + or - 45 and 0 deg plies next to each other or with + or - 45 deg plies next to layers of adhesive interleaving. Results of these tests are compared with analytical results based on finite elements.
NASA Astrophysics Data System (ADS)
Kerr-Anderson, Eric
Structural composite laminates were ballistically impacted while under in-plane compressive pre-stress. Residual properties, damage characterization, and energy absorption were compared to determine synergistic effects of in-plane compressive pre-stress and impact velocity. A fixture was developed to apply in-plane compressive loads up to 30 tons to structural composites during an impact event using a single-stage light-gas gun. Observed failure modes included typical conical delamination, the development of an impact initiated shear crack (IISC), and the shear failure of a pre-stressed composite due to impact. It was observed that the compressive failure threshold quadratically decreased in relation to the impact velocity up to velocities that caused partial penetration. For all laminates impacted at velocities causing partial or full penetration up to 350 ms-1, the failure threshold was consistent and used as an experimental normalization. Samples impacted below 65% of the failure threshold witnessed no significant change in damage morphology or residual properties when compared to typical conical delamination. Samples impacted above 65% of the failure threshold witnessed additional damage in the form of a shear crack extending perpendicular to the applied load from the point of impact. The presence of an IISC reduced the residual properties and even caused failure upon impact at extreme combinations. Four failure envelopes have been established as: transient failure, steady state failure, impact initiated shear crack, and conical damage. Boundaries and empirically based equations for residual compressive strength have been developed for each envelope with relation to two E-glass/vinyl ester laminate systems. Many aspects of pre-stressed impact have been individually examined, but there have been no comprehensive examinations of pre-stressed impact. This research has resulted in the exploration and characterization of compressively pre-stressed damage for impact velocities resulting in reflection, partial penetration, and penetration at pre-stress levels resulting in conical damage, shear cracking, and failure.
Reliability Analysis of Systems Subject to First-Passage Failure
NASA Technical Reports Server (NTRS)
Lutes, Loren D.; Sarkani, Shahram
2009-01-01
An obvious goal of reliability analysis is the avoidance of system failure. However, it is generally recognized that it is often not feasible to design a practical or useful system for which failure is impossible. Thus it is necessary to use techniques that estimate the likelihood of failure based on modeling the uncertainty about such items as the demands on and capacities of various elements in the system. This usually involves the use of probability theory, and a design is considered acceptable if it has a sufficiently small probability of failure. This report contains findings of analyses of systems subject to first-passage failure.
ERIC Educational Resources Information Center
Ceja, Rafael, Jr.
2012-01-01
The enactment of the NCLB Act of 2001 and its legislative mandates for accountability testing throughout the nation brought to the forefront the issue of data-driven decision making. This emphasis on improving education has been spurred due to the alleged failure of the public school system. As a result, the role of administrators has evolved to…
Metric Selection for Evaluation of Human Supervisory Control Systems
2009-12-01
finding a significant effect when there is none becomes more likely. The inflation of type I error due to multiple dependent variables can be handled...with multivariate analysis techniques, such as Multivariate Analysis of Variance (MANOVA) (Johnson & Wichern, 2002). However, it should be noted that...the few significant differences among many insignificant ones. The best way to avoid failure to identify significant differences is to design an
Radiation effects in spacecraft electronics
NASA Technical Reports Server (NTRS)
Raymond, James P.
1989-01-01
Effects on the internal spacecraft electronics due to exposure to the natural and enhanced space radiation environment will be reviewed. The emphasis will be placed on the description of the nature of both the exposure environment and failure mechanisms in semiconductors. Understanding both the system environment and device effects is critical in the use of laboratory simulation environments to obtain the data necessary to design and qualify components for successful application.
[Haemophilus influenzae type b in Italy--after thirty years of vaccination may we lower our guard?].
Terracciano, Elisa; Zaratti, Laura; Franco, Elisabetta
2015-01-01
Haemophilus influenzae b (Hib) is responsible for meningitis, systemic infections and acute respiratory illness, especially in children. The use of the conjugate vaccines against Hib reduced the incidence of the disease worldwide. In Italy, after the decrease resulted from vaccination, the disease may reappear due to the reduction in vaccination coverage, the presence of infections in adults and vaccine failures.
Experimental Investigation of Ice Phase Change Material Heat Exchangers
NASA Technical Reports Server (NTRS)
Leimkuehler, Thomas O.; Stephan, Ryan A.
2011-01-01
Phase change materials (PCM) may be useful for spacecraft thermal control systems that involve cyclical heat loads or cyclical thermal environments. Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. This can result in a decreased turndown ratio for the radiator and a reduced system mass. The use of water as a PCM rather than the more traditional paraffin wax has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. A number of ice PCM heat exchangers were fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion were investigated. This paper presents an overview of the results of this investigation from the past three years.
Experimental Investigation of Ice Phase Change Material Heat Exchangers
NASA Technical Reports Server (NTRS)
Leimkuehler, Thomas O.; Stephan, Ryan A.
2012-01-01
Phase change materials (PCM) may be useful for spacecraft thermal control systems that involve cyclical heat loads or cyclical thermal environments. Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. This can result in a decreased turndown ratio for the radiator and a reduced system mass. The use of water as a PCM rather than the more traditional paraffin wax has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. A number of ice PCM heat exchangers were fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion were investigated. This paper presents an overview of the results of this investigation from the past three years.
Role of nocturnal rostral fluid shift in the pathogenesis of obstructive and central sleep apnoea.
White, Laura H; Bradley, T Douglas
2013-03-01
Obstructive sleep apnoea (OSA) is common in the general population and increases the risk of motor vehicle accidents due to hypersomnolence from sleep disruption, and risk of cardiovascular diseases owing to repetitive hypoxia, sympathetic nervous system activation, and systemic inflammation. In contrast, central sleep apnoea (CSA) is rare in the general population. Although their pathogenesis is multifactorial, the prevalence of both OSA and CSA is increased in patients with fluid retaining states, especially heart failure, where they are associated with increased mortality risk. This observation suggests that fluid retention may contribute to the pathogenesis of both OSA and CSA. According to this hypothesis, during the day fluid accumulates in the intravascular and interstitial spaces of the legs due to gravity, and upon lying down at night redistributes rostrally, again owing to gravity. Some of this fluid may accumulate in the neck, increasing tissue pressure and causing the upper airway to narrow, thereby increasing its collapsibility and predisposing to OSA. In heart failure patients, with increased rostral fluid shift, fluid may additionally accumulate in the lungs, provoking hyperventilation and hypocapnia, driving below the apnoea threshold, leading to CSA. This review article will explore mechanisms by which overnight rostral fluid shift, and its prevention, can contribute to the pathogenesis and therapy of sleep apnoea.
Role of nocturnal rostral fluid shift in the pathogenesis of obstructive and central sleep apnoea
White, Laura H; Bradley, T Douglas
2013-01-01
Obstructive sleep apnoea (OSA) is common in the general population and increases the risk of motor vehicle accidents due to hypersomnolence from sleep disruption, and risk of cardiovascular diseases owing to repetitive hypoxia, sympathetic nervous system activation, and systemic inflammation. In contrast, central sleep apnoea (CSA) is rare in the general population. Although their pathogenesis is multifactorial, the prevalence of both OSA and CSA is increased in patients with fluid retaining states, especially heart failure, where they are associated with increased mortality risk. This observation suggests that fluid retention may contribute to the pathogenesis of both OSA and CSA. According to this hypothesis, during the day fluid accumulates in the intravascular and interstitial spaces of the legs due to gravity, and upon lying down at night redistributes rostrally, again owing to gravity. Some of this fluid may accumulate in the neck, increasing tissue pressure and causing the upper airway to narrow, thereby increasing its collapsibility and predisposing to OSA. In heart failure patients, with increased rostral fluid shift, fluid may additionally accumulate in the lungs, provoking hyperventilation and hypocapnia, driving below the apnoea threshold, leading to CSA. This review article will explore mechanisms by which overnight rostral fluid shift, and its prevention, can contribute to the pathogenesis and therapy of sleep apnoea. PMID:23230237
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vroomen, G.L.M.; Lievens, S.S.; Maes, J.P.
1999-08-01
EPDM (ethylene-propylene rubber) has been used for more than 25 years as the main elastomer in radiator hoses because it offers a well-balanced price/performance ratio in this field of application. Some years ago the automotive and rubber industry became aware of a problem called electrochemical degradation and cracking. Cooling systems broke down due to a typical cracking failure of some radiator hoses. Different test methods were developed to simulate and solve the problem on laboratory scale. The influence of different variables with respect to the electrochemical degradation and cracking. Cooling systems broke down due to a typical cracking failure ofmore » some radiator hoses. Different test methods were developed to simulate and solve the problem on laboratory scale. The influence of different variables with respect to the electrochemical degradation process has been investigated, but until recently the influence of the engine coolant was ignored. Using a test method developed by DSM elastomers, the influence of the composition of the engine coolant as well as of the EPDM composition has now been evaluated. This paper gives an overview of test results with different coolant technologies and offers a plausible explanation of the degradation mechanisms as a function of the elastomer composition.« less
The HAL 9000 Space Operating System Real-Time Planning Engine Design and Operations Requirements
NASA Technical Reports Server (NTRS)
Stetson, Howard; Watson, Michael D.; Shaughnessy, Ray
2012-01-01
In support of future deep space manned missions, an autonomous/automated vehicle, providing crew autonomy and an autonomous response planning system, will be required due to the light time delays in communication. Vehicle capabilities as a whole must provide for tactical response to vehicle system failures and space environmental effects induced failures, for risk mitigation of permanent loss of communication with Earth, and for assured crew return capabilities. The complexity of human rated space systems and the limited crew sizes and crew skills mix drive the need for a robust autonomous capability on-board the vehicle. The HAL 9000 Space Operating System[2] designed for such missions and space craft includes the first distributed real-time planning / re-planning system. This paper will detail the software architecture of the multiple planning engine system, and the interface design for plan changes, approval and implementation that is performed autonomously. Operations scenarios will be defined for analysis of the planning engines operations and its requirements for nominal / off nominal activities. An assessment of the distributed realtime re-planning system, in the defined operations environment, will be provided as well as findings as it pertains to the vehicle, crew, and mission control requirements needed for implementation.
Real-Time Sensor Validation System Developed for Reusable Launch Vehicle Testbed
NASA Technical Reports Server (NTRS)
Jankovsky, Amy L.
1997-01-01
A real-time system for validating sensor health has been developed for the reusable launch vehicle (RLV) program. This system, which is part of the propulsion checkout and control system (PCCS), was designed for use in an integrated propulsion technology demonstrator testbed built by Rockwell International and located at the NASA Marshall Space Flight Center. Work on the sensor health validation system, a result of an industry-NASA partnership, was completed at the NASA Lewis Research Center, then delivered to Marshall for integration and testing. The sensor validation software performs three basic functions: it identifies failed sensors, it provides reconstructed signals for failed sensors, and it identifies off-nominal system transient behavior that cannot be attributed to a failed sensor. The code is initiated by host software before the start of a propulsion system test, and it is called by the host program every control cycle. The output is posted to global memory for use by other PCCS modules. Output includes a list indicating the status of each sensor (i.e., failed, healthy, or reconstructed) and a list of features that are not due to a sensor failure. If a sensor failure is found, the system modifies that sensor's data array by substituting a reconstructed signal, when possible, for use by other PCCS modules.
Hybrid boosters for future launch vehicles
NASA Astrophysics Data System (ADS)
Dargies, E.; Lo, R. E.
1987-10-01
Hybrid rocket propulsion systems furnish the advantages of much higher safety levels, due both to shut-down capability in case of ignition failure to one unit and the potential choice of nontoxic propellant combinations, such as LOX/polyethylene; they nevertheless yield performance levels comparable or superior to those of solid rocket boosters. Attention is presently given to the results of DFVLR analytical model studies of hybrid propulsion systems, with attention to solid fuel grain geometrical design and propellant grain surface ablation rate. The safety of hybrid rockets recommends them for use by manned spacecraft.
Kotov in SM during Progress 37P Docking
2010-05-01
ISS023-E-031743 (1 May 2010) --- Russian cosmonaut Oleg Kotov, Expedition 23 commander, is pictured at the manual TORU docking system controls in the Zvezda Service Module of the International Space Station just before conducting a manual control docking of the Progress 37 due to a jet failure on the Progress that forced a shutdown of the Kurs automated rendezvous system. Progress 37 docked to the Pirs Docking Compartment at 2:30 p.m. (EDT) on May 1, 2010, after a three-day flight from the Baikonur Cosmodrome in Kazakhstan.
Forecasting overhaul or replacement intervals based on estimated system failure intensity
NASA Astrophysics Data System (ADS)
Gannon, James M.
1994-12-01
System reliability can be expressed in terms of the pattern of failure events over time. Assuming a nonhomogeneous Poisson process and Weibull intensity function for complex repairable system failures, the degree of system deterioration can be approximated. Maximum likelihood estimators (MLE's) for the system Rate of Occurrence of Failure (ROCOF) function are presented. Evaluating the integral of the ROCOF over annual usage intervals yields the expected number of annual system failures. By associating a cost of failure with the expected number of failures, budget and program policy decisions can be made based on expected future maintenance costs. Monte Carlo simulation is used to estimate the range and the distribution of the net present value and internal rate of return of alternative cash flows based on the distributions of the cost inputs and confidence intervals of the MLE's.
NASA Technical Reports Server (NTRS)
Shepard, Kyle; Sager, Paul; Kusunoki, Sid; Porter, John; Campion, AL; Mouritzan, Gunnar; Glunt, George; Vegter, George; Koontz, Rob
1993-01-01
Several topics are presented in viewgraph form which together encompass the preliminary assessment of nuclear thermal rocket engine clustering. The study objectives, schedule, flow, and groundrules are covered. This is followed by the NASA groundrules mission and our interpretation of the associated operational scenario. The NASA reference vehicle is illustrated, then the four propulsion system options are examined. Each propulsion system's preliminary design, fluid systems, operating characteristics, thrust structure, dimensions, and mass properties are detailed as well as the associated key propulsion system/vehicle interfaces. A brief series of systems analysis is also covered including: thrust vector control requirements, engine out possibilities, propulsion system failure modes, surviving system requirements, and technology requirements. An assessment of vehicle/propulsion system impacts due to the lessons learned are presented.
Anesthetic cartridge system under evaluation.
Cooley, R L; Lubow, R M
1981-01-01
The problem of glass breakage in the local anesthetic cartridge system was evaluated under laboratory conditions with a mechanical testing machine. The anticipated breakage of the glass did not occur with any frequency, as the rubber stopper produced more uniform failures of the system. The glass cartridge appeared to be quite reliable and resistant to breakage.Local anesthetics have been used for many years to provide patients temporary freedom from pain. Local anesthetic solutions are in wide use in both dentistry and medicine and are the most frequently used drugs in dentistry. Various estimates place the number of injections at approximately one half million daily or 125 million injections per year.These drugs and the armamentarium necessary to administer them have proven to be safe and reliable. Only rarely are there reports of sensitivity to the anesthetic solution or breakage of needles.. Sterility of the solutions has not been a problem as they are carefully processed and evaluated at the factory. Although there are sporadic reports of loss of sterility, this has been attributed to the reuse of the anesthetic cartridges on more than one patient. Monheim states "The success of the cartridge system in dentistry has been due to the sincerity, honesty, and high standards of the manufacturers in giving the profession a near-perfect product." However, on occassion a glass cartridge will break or shatter when inserting the harpoon into the rubber stopper or even during injection. Cooley et al reported on eye injuries occurring in the dental office, one of which was due to glass from a local anesthetic cartridge that exploded and propelled particles into the patient's eye. Forrest evaluated syringes, needles, and cartridges and reported that one brand (made in Britain) fractured more often than any other, but that the fracture rate was too low to be of any consequence.It is apparent that glass cartridges will fracture or burst from time to time. This study evaluates the cartridge system with carefully controlled laboratory procedures. The cartridges were tested under various pressures and conditions in an attempt to determine the causes of failure and when such failure may be anticipated.
Operational considerations in monitoring oxygen levels at the National Transonic Facility
NASA Technical Reports Server (NTRS)
Zalenski, M. A.; Rowe, E. L.; Mcphee, J. R.
1985-01-01
Laboratory monitoring of the level of oxygen in sample gas mixtures is a process which can be performed with accurate and repeatable results. Operations at the National Transonic Facility require the storage and pumping of large volumes of liquid nitrogen. To protect against the possibility of a fault resulting in a localized oxygen deficient atmosphere, the facility is equipped with a monitoring system with an array of sensors. During the early operational stages, the system produced recurrent alarms, none of which could be traced to a true oxygen deficiency. A thorough analysis of the system was undertaken with primary emphasis placed on the sensor units. These units sense the partial pressure of oxygen which, after signal conditioning, is presented as a % by volume indication at the system output. It was determined that many of the problems experienced were due to a lack of proper accounting for the partial pressure/% by volume relationship, with a secondary cause being premature sensor failure. Procedures were established to consider atmospherically induced partial pressure variations. Sensor rebuilding techniques were examined, and those elements contributing to premature sensor failure were identified. The system now operates with a high degree of confidence and reliability.
PRA (Probabilistic Risk Assessment) Applications Program for inspection at Oconee Unit 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gore, B.F.; Vo, T.V.; Harris, M.S.
1987-10-01
The extensive Oconee-3 PRA performed by EPRI has been analyzed to identify plant systems and components important to minimizing public risk, and to identify the primary failure modes of these components. This information has been tabulated, and correlated with inspection modules from the NRC Inspection and Enforcement Manual. The report presents a series of tables, organized by system and prioritized by public risk (in person-rem per year), which identify components associated with 98% of the inspectable risk due to plant operation. External events (earthquakes, tornadoes, fires and floods) are not addressed because inspections cannot directly minimize the risks from thesemore » events; however, flooding caused by the breach of internal systems is addressed. The systems addressed, in descending order of risk importance, are: Reactor Building Spray, R B Cooling, Condenser Circulating Water, Safety Relief Valves, Low Pressure Injection, Standby Shutdown Facility-High Pressure Injection, Low-Pressure Service Water, and Emergency Feedwater. This ranking is based on the Fussel-Vesely measure of risk importance, i.e., the fraction of the total risk which involves failures of the system of interest. 8 refs., 25 tabs.« less
Anger, Hostility, and Re-hospitalizations in Patients with Heart Failure
2015-04-08
Discharge Survey (NHDS), capturing years 1979 to 2004, approximately 80% of individuals who were hospitalized due to heart failure were ~65...Rosuvastatin Multinational Trial In Heart Failure ( CORONA ). Circulation. Heart failure 2. Azevedo FB, Wang YP, Goulart AC, Lotufo PA, Bensenor IM. 2010...from the National Hospital Discharge Surveys 1980-2006. International journal of cardiology 149:39-45 33 . Luttik ML, Jaarsma T, Moser DK, Sanderman R
NASA Astrophysics Data System (ADS)
Iskandar, I.
2018-03-01
The exponential distribution is the most widely used reliability analysis. This distribution is very suitable for representing the lengths of life of many cases and is available in a simple statistical form. The characteristic of this distribution is a constant hazard rate. The exponential distribution is the lower rank of the Weibull distributions. In this paper our effort is to introduce the basic notions that constitute an exponential competing risks model in reliability analysis using Bayesian analysis approach and presenting their analytic methods. The cases are limited to the models with independent causes of failure. A non-informative prior distribution is used in our analysis. This model describes the likelihood function and follows with the description of the posterior function and the estimations of the point, interval, hazard function, and reliability. The net probability of failure if only one specific risk is present, crude probability of failure due to a specific risk in the presence of other causes, and partial crude probabilities are also included.
Failure analysis of electrolyte-supported solid oxide fuel cells
NASA Astrophysics Data System (ADS)
Fleischhauer, Felix; Tiefenauer, Andreas; Graule, Thomas; Danzer, Robert; Mai, Andreas; Kuebler, Jakob
2014-07-01
For solid oxide fuel cells (SOFCs) one key aspect is the structural integrity of the cell and hence its thermo mechanical long term behaviour. The present study investigates the failure mechanisms and the actual causes for fracture of electrolyte supported SOFCs which were run using the current μ-CHP system of Hexis AG, Winterthur - Switzerland under lab conditions or at customer sites for up to 40,000 h. In a first step several operated stacks were demounted for post-mortem inspection, followed by a fractographic evaluation of the failed cells. The respective findings are then set into a larger picture including an analysis of the present stresses acting on the cell like thermal and residual stresses and the measurements regarding the temperature dependent electrolyte strength. For all investigated stacks, the mechanical failure of individual cells can be attributed to locally acting bending loads, which rise due to an inhomogeneous and uneven contact between the metallic interconnect and the cell.
Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware
NASA Technical Reports Server (NTRS)
Davis, S. J.; Deweese, C. D.
1995-01-01
HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.
Melchert, O; Katzgraber, Helmut G; Novotny, M A
2016-04-01
We estimate the critical thresholds of bond and site percolation on nonplanar, effectively two-dimensional graphs with chimeralike topology. The building blocks of these graphs are complete and symmetric bipartite subgraphs of size 2n, referred to as K_{n,n} graphs. For the numerical simulations we use an efficient union-find-based algorithm and employ a finite-size scaling analysis to obtain the critical properties for both bond and site percolation. We report the respective percolation thresholds for different sizes of the bipartite subgraph and verify that the associated universality class is that of standard two-dimensional percolation. For the canonical chimera graph used in the D-Wave Systems Inc. quantum annealer (n=4), we discuss device failure in terms of network vulnerability, i.e., we determine the critical fraction of qubits and couplers that can be absent due to random failures prior to losing large-scale connectivity throughout the device.
[Specific aspects and care of lung involvement in adults with cystic fibrosis].
Pin, I; Grenet, D; Scheid, P; Domblides, P; Stern, M; Hubert, D
2000-08-01
Respiratory impairment is present in almost all adult cystic fibrosis patients and makes the prognosis. Viscous, infected and abundant secretions, inflammation and bronchial oedema, bronchoconstriction and respiratory muscle fatigue lead to airway obstruction, bronchiectasis and respiratory failure. The disease is preferentially located in the upper lobes. Exacerbations of the disease are due to bronchial infections and are often responsible for drops of the respiratory function. Regular spirometric surveillance is fundamental for the prognosis and the assessment of the effects of the treatment. Among adult patients chronic colonisation with mucoid and often multiresistant strains of Pseudomonas Aeruginosa are common. It is treated with i.v. high doses antibiotic courses and nebulized antibiotics between i.v. courses. Respiratory failure may require long term oxygen and non invasive mechanical ventilation. Systemic hypervascularization around the bronchiectasis may lead to moderate to severe hemoptysis, which may require embolization. Pneumothorax are associated with poor prognosis and are treated by pleural drainage and if failure by thoracoscopy.
Skylab technology electrical power system
NASA Technical Reports Server (NTRS)
Woosley, A. P.; Smith, O. B.; Nassen, H. S.
1974-01-01
The solar array/battery power systems for the Skylab vehicle were designed to operate in a solar inertial pointing mode to provide power continuously to the Skylab. Questions of power management are considered, taking into account difficulties caused by the reduction in power system performance due to the effects of structural failure occurring during the launching process. The performance of the solar array of the Apollo Telescope Mount Power System is discussed along with the Orbital Workshop solar array performance and the Airlock Module power conditioning group performance. A list is presented of a number of items which have been identified during mission monitoring and are recommended for electrical power system concepts, designs, and operation for future spacecraft.
The Digestive System and Nutritional Considerations for Individuals with Rett Syndrome
Lotan, Meir; Zysman, Lilit
2006-01-01
Rett syndrome (RS) is a neurodevelopmental syndrome of genetic origin that mainly affects females. Individuals diagnosed with RS exhibit a variety of functional difficulties that impair their quality of life. One of the affected systems is the digestive system, where 74% of persons with RS have abnormal functioning. The affected digestive system causes this population to present an array of problems, such as gastroesophageal reflux (GER), constipation, and malnutrition, leading to failure to thrive (FTT), which resolves in reduced functional ability. Due to the severe effects of the dysfunctional digestive system of individuals with RS, this article will describe the problems common to this population, as well as propose some clinical suggestions for intervention. . PMID:17195872
NASA Technical Reports Server (NTRS)
Tiller, Smith E.; Sullivan, David
1992-01-01
An overview of a self-contained Direct Energy Transfer Power System which was developed to provide power to the Long Duration Exposure Facility (LDEF) Low-Temperature Heat Pipe Experiment Package is presented. The power system operated successfully for the entire mission. Data recorded by the onboard recorder shows that the system operated within design specifications. Other than unanticipated overcharging of the battery, the power system operated as expected for nearly 32,000 low earth orbit cycles, and was still operational when tested after the LDEF recovery. Some physical damage was sustained by the solar array panels due to micrometeoroid hits, but there were not electrical failures.
Patient-Specific Modeling of Interventricular Hemodynamics in Single Ventricle Physiology
NASA Astrophysics Data System (ADS)
Vedula, Vijay; Feinstein, Jeffrey; Marsden, Alison
2016-11-01
Single ventricle (SV) congenital heart defects, in which babies are born with only functional ventricle, lead to significant morbidity and mortality with over 30% of patients developing heart failure prior to adulthood. Newborns with SV physiology typically undergo three palliative surgeries, in which the SV becomes the systemic pumping chamber. Depending on which ventricle performs the systemic function, patients are classified as having either a single left ventricle (SLV) or a single right ventricle (SRV), with SRV patients at higher risk of failure. As the native right ventricles are not designed to meet systemic demands, they undergo remodeling leading to abnormal hemodynamics. The hemodynamic characteristics of SLVs compared with SRVs is not well established. We present a validated computational framework for performing patient-specific modeling of ventricular flows, and apply it across 6 SV patients (3SLV + 3SRV), comparing hemodynamic conditions between the two subgroups. Simulations are performed with a stabilized finite element method coupled with an immersed boundary method for modeling heart valves. We discuss identification of hemodynamic biomarkers of ventricular remodeling for early risk assessment of failure. This research is supported in part by the Stanford Child Health Research Institute and the Stanford NIH-NCATS-CTSA through Grant UL1 TR001085 and due to U.S. National Institute of Health through NIH NHLBI R01 Grants 5R01HL129727-02 and 5R01HL121754-03.
Hu, Pao-Hsueh; Hu, Hsiao-Chen; Huang, Hui-Ju; Chao, Hui-Lin; Lei, Ei-Fang
2014-04-01
Because surgical pathology specimens are crucial to the diagnosis and treatment of disease, it is critical that they be collected and transported safely and securely. Due to recent near-miss events in our department, we used the healthcare failure model and effect analysis to identify 14 potential perils in the specimen collection and transportation process. Improvement and prevention strategies were developed accordingly to improve quality of care. Using health care failure mode and effect analysis (HFMEA) may improve the surgical specimen transportation process and reduce the rate of surgical specimen rejection. Rectify standard operating procedures for surgical pathology specimen collection and transportation. Create educational videos and posters. Rectify methods of specimen verification. Organize and create an online and instantaneous management system for specimen tracking and specimen rejection. Implementation of the new surgical specimen transportation process effectively eliminated the 14 identified potential perils. In addition, the specimen rejection fell from 0.86% to 0.03%. This project was applied to improve the specimen transportation process, enhance interdisciplinary cooperation, and improve the patient-centered healthcare system. The creation and implementation of an online information system significantly facilitates specimen tracking, hospital cost reductions, and patient safety improvements. The success in our department is currently being replicated across all departments in our hospital that transport specimens. Our experience and strategy may be applied to inter-hospital specimen transportation in the future.
Lancioni, Giulio E; O'Reilly, Mark F; Cuvo, Anthony J; Singh, Nirbhay N; Sigafoos, Jeff; Didden, Robert
2007-01-01
This paper provides an overview of the literature dealing with the use of the Picture Exchange Communication System (PECS) and voice output communication aids (VOCAs) for promoting the performance of requests by students with developmental disabilities. Computerized and manual searches were carried out to identify the studies published during the last 15 years (i.e., the period between 1992 and 2006 during which PECS and VOCA approaches became popular). Thirty-seven studies were identified and then divided into three groups concerning the use of the PECS or equivalents, the use of VOCAs or equivalents, and the comparison of both these approaches, respectively. Of the 173 students involved in studies using the PECS or equivalents only three could be considered failures, while a fourth one did not progress in the program due to illness. Similarly, of the 39 students who used VOCAs or equivalents only three could be considered failures, while one was partly successful. Finally, of the 11 students involved in the comparisons between PECS and VOCAs none could be classified as a failure. The results are very encouraging but methodological concerns and the relatively limited use of the systems in terms of request items and request opportunities suggest caution. Caution may also be needed in interpreting the reported similarities between the two systems in usability and effectiveness.
DEPEND - A design environment for prediction and evaluation of system dependability
NASA Technical Reports Server (NTRS)
Goswami, Kumar K.; Iyer, Ravishankar K.
1990-01-01
The development of DEPEND, an integrated simulation environment for the design and dependability analysis of fault-tolerant systems, is described. DEPEND models both hardware and software components at a functional level, and allows automatic failure injection to assess system performance and reliability. It relieves the user of the work needed to inject failures, maintain statistics, and output reports. The automatic failure injection scheme is geared toward evaluating a system under high stress (workload) conditions. The failures that are injected can affect both hardware and software components. To illustrate the capability of the simulator, a distributed system which employs a prediction-based, dynamic load-balancing heuristic is evaluated. Experiments were conducted to determine the impact of failures on system performance and to identify the failures to which the system is especially susceptible.
[Ascitic peritonitis due to Candida albicans].
Suárez, A; Otero, L; Navascués, C A; Menéndez, M T; Román, F J; García, R; Saro, C; Rodríguez, A
1994-09-01
We report a case of spontaneous peritonitis due to Candida albicans, in a diabetic patient with alcoholic liver cirrhosis, ascites, gastrointestinal bleeding from esophageal varices, sepsis, renal failure and encephalopathy. These factors, added to prolonged antibiotic therapy and instrumental manipulations, could have resulted in the colonization by Candida, usually described in secondary peritonitis, but perhaps underdiagnosed in cirrhotic patients with spontaneous peritonitis and severe multiorgan failure.
Respiratory failure associated with hypoventilation in a patient with severe hypothyroidism
Fukusumi, Munehisa; Iidaka, Toshiko; Mouri, Atsuto; Hamamoto, Yoichiro; Kamimura, Mitsuhiro
2014-01-01
A 70-year-old Japanese man was admitted to hospital because of decreased consciousness due to type II respiratory failure. Severe hypothyroidism was diagnosed and considered to be associated with hypoventilation due to respiratory muscle dysfunction and sleep apnea syndrome. His status was improved partially by replacement of thyroid hormone. Despite maintaining a euthyroid state, improvement of respiratory muscle dysfunction was incomplete. PMID:25473574
49 CFR 214.529 - In-service failure of primary braking system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false In-service failure of primary braking system. 214... Maintenance Machines and Hi-Rail Vehicles § 214.529 In-service failure of primary braking system. (a) In the event of a total in-service failure of its primary braking system, an on-track roadway maintenance...
49 CFR 214.529 - In-service failure of primary braking system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false In-service failure of primary braking system. 214... Maintenance Machines and Hi-Rail Vehicles § 214.529 In-service failure of primary braking system. (a) In the event of a total in-service failure of its primary braking system, an on-track roadway maintenance...
49 CFR 214.529 - In-service failure of primary braking system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Maintenance Machines and Hi-Rail Vehicles § 214.529 In-service failure of primary braking system. (a) In the event of a total in-service failure of its primary braking system, an on-track roadway maintenance... 49 Transportation 4 2010-10-01 2010-10-01 false In-service failure of primary braking system. 214...
Studies in knowledge-based diagnosis of failures in robotic assembly
NASA Technical Reports Server (NTRS)
Lam, Raymond K.; Pollard, Nancy S.; Desai, Rajiv S.
1990-01-01
The telerobot diagnostic system (TDS) is a knowledge-based system that is being developed for identification and diagnosis of failures in the space robotic domain. The system is able to isolate the symptoms of the failure, generate failure hypotheses based on these symptoms, and test their validity at various levels by interpreting or simulating the effects of the hypotheses on results of plan execution. The implementation of the TDS is outlined. The classification of failures and the types of system models used by the TDS are discussed. A detailed example of the TDS approach to failure diagnosis is provided.
Morgan, Peter B.; Hanlon, Alexandra L.; Horwitz, Eric M.; Buyyounouski, Mark K.; Uzzo, Robert G.; Pollack, Alan
2007-01-01
Condensed Abstract The timing of biochemical failure and distant metastasis after radiotherapy for low, intermediate and high-risk prostate cancer was determined. The patterns of failure suggest that the majority of early failures were due to subclinical micrometastases present at diagnosis, whereas a late wave of metastasis at 10–12 years in every risk group was consistent with tumor spread from local persistence of disease. Background The relationship of prostate cancer risk group stratification and the timing of biochemical failure (BF) and distant metastasis (DM) is not well defined. We sought to differentiate early failures due to subclinical micrometastasis at presentation from late failures due to local persistence. Methods A total of 1833 men with clinically localized prostate cancer treated with 3D-conformal radiotherapy with or without short-term androgen deprivation were retrospectively analyzed. The interval hazard rates of DM and BF, using ASTRO and Phoenix (Nadir+2) definitions, were determined for men with low, intermediate, and high risk disease. Results Median follow-up was 67 months. Multivariate analysis showed that increasing risk group was independently associated with higher ASTRO BF (P<.0001) and Nadir+2 BF (P<.0001). The preponderance (87%) of ASTRO BF occurred ≤4 years after RT, while Nadir+2 BF was more evenly spread over years 1–12, with 43% at >4 years. The hazard of Nadir+2 BF persisted in years 8–12 in all risk groups. The interval hazard function for DM appeared to be biphasic (early and late peaks) for intermediate and high risk patients, but no distinct early wave was evident for low risk patients. Conclusions ASTRO BF underestimates late BF due to backdating. Local persistence of disease is suggested by delayed Nadir+2 BF and subsequent late DM in every risk group. The paucity of early DM among those with low risk tumors supports the hypothesis that occult micrometastases contributed to the early wave. PMID:17520705
NASA Astrophysics Data System (ADS)
Oommen, T.; Baise, L. G.; Gens, R.; Prakash, A.; Gupta, R. P.
2008-12-01
Seismic liquefaction is the loss of strength of soil due to shaking that leads to various ground failures such as lateral spreading, settlements, tilting, and sand boils. It is important to document these failures after earthquakes to advance our study of when and where liquefaction occurs. The current approach of mapping these failures by field investigation teams suffers due to the inaccessibility to some of the sites immediately after the event, short life of some of these failures, difficulties in mapping the aerial extent of the failure, incomplete coverage etc. After the 2001 Bhuj earthquake (India), researchers, using the Indian remote sensing satellite, illustrated that satellite remote sensing can provide a synoptic view of the terrain and offer unbiased estimates of liquefaction failures. However, a multisensor (data from different sensors onboard of the same or different satellites) and multispectral (data collected in different spectral regions) approach is needed to efficiently document liquefaction incidences and/or its potential of occurrence due to the possibility of a particular satellite being located inappropriately to image an area shortly after an earthquake. The use of SAR satellite imagery ensures the acquisition of data in all weather conditions at day and night as well as information complimentary to the optical data sets. In this study, we analyze the applicability of the various satellites (Landsat, RADARSAT, Terra-MISR, IRS-1C, IRS-1D) in mapping liquefaction failures after the 2001 Bhuj earthquake using Support Vector Data Description (SVDD). The SVDD is a kernel based nonparametric outlier detection algorithm inspired by the Support Vector Machines (SVMs), which is a new generation learning algorithm based on the statistical learning theory. We present the applicability of SVDD for unsupervised change-detection studies (i.e. to identify post-earthquake liquefaction failures). The liquefaction occurrences identified from the different satellites using SVDD have been compared to the ground truth in terms of documented liquefaction failures by other researchers. We present the applicability and appropriateness of the various satellites and spectral regions for documenting liquefaction related failures. Results illustrate that the SVDD is a promising unsupervised change-detection algorithm, which can help in automating the documentation of earthquake induced liquefaction failures.
Vikholm, Per; Schiller, Petter; Hellgren, Laila
2014-01-01
OBJECTIVES Right ventricular failure after left ventricular assist device implantation is a serious complication with high rates of mortality and morbidity. It has been demonstrated in experimental settings that volume exclusion of the right ventricle with a modified Glenn shunt can improve haemodynamics during ischaemic right ventricular failure. However, the concept of a modified Glenn shunt is dependent on a normal pulmonary vascular resistance, which can limit its use in some patients. The aim of this study was to explore the effects of volume exclusion with a modified Glenn shunt during right ventricular failure due to pulmonary banding, and to study the alterations in genetic expression in the right ventricle due to pressure and volume overload. METHODS Experimental right ventricular failure was induced in pigs (n = 11) through 2 h of pulmonary banding. The pigs were randomized to either treatment with a modified Glenn shunt and pulmonary banding (n = 6) or solely pulmonary banding (n = 5) as a control group. Haemodynamic measurements, blood samples and right ventricular biopsies for genetic analysis were sampled at baseline, at right ventricular failure (i.e. 2 h of pulmonary banding) and 1 h post-right ventricular failure in both groups. RESULTS Right atrial pressure increased from 10 mmHg (9.0–12) to 18 mmHg (16–22) (P < 0.01) and the right ventricular pressure from 31 mmHg (26–35) to 57 mmHg (49–61) (P < 0.01) after pulmonary banding. Subsequent treatment with the modified Glenn shunt resulted in a decrease in right atrial pressure to 13 mmHg (11–14) (P = 0.03). In the control group, right atrial pressure was unchanged at 19 mmHg (16–20) (P = 0.18). At right heart failure, there was an up-regulation of genes associated with heart failure, inflammation, angiogenesis, negative regulation of cell death and proliferation. CONCLUSIONS Volume exclusion with a modified Glenn shunt during right ventricular failure reduced venous congestion compared with the control group. The state of right heart failure was verified through genetic expressional changes. PMID:24396048
20 CFR 416.730 - Penalty period: Three or more failures to report.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Penalty period: Three or more failures to report. 416.730 Section 416.730 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY... period. The due date and the failure to report on time are the important factors in establishing a...
A THEORETICAL MODEL FOR RESEARCH IN EDUCATION.
ERIC Educational Resources Information Center
ARMSTRONG, JENNY R.
THE FAILURE OF EDUCATIONAL RESEARCH TO CONTRIBUTE LARGE CONSISTENT BODIES OF KNOWLEDGE ABOUT THE EDUCATIONAL PROCESS HAS BEEN DUE TO FIVE MAJOR FACTORS--(1) FAULTY EXPERIMENTAL DESIGN, (2) FAILURE TO CONSIDER ALL OF THE MAJOR INPUT ELEMENTS OF THE EDUCATIONAL PROCESS, (3) FAILURE TO MAKE MEANINGFUL COMPARISONS (FOR EXAMPLE THE CONTROL GROUP IS NOT…