Sample records for system iris peer

  1. Final Report from the External Peer Review of the IRIS ...

    EPA Pesticide Factsheets

    This document is the final report for the 2004 external peer review for the EPA IRIS Reassessment of the Inhalation Carcinogenicity of Naphthalene, prepared by the Office of Research and Development's National Center for Environmental Assessment (NCEA), for the Integrated Risk Information System (IRIS) Database. A panel of external peer reviewers met to discuss the IRIS report and their responses to the charge questions on July 30, 2004. This document contains the final written comments of the external peer reviewers. This document is the final report for the 2004 external peer review for the IRIS Reassessment of the Inhalation Carcinogenicity of Naphthalene, prepared by the U.S. Environmental Protection Agency (EPA), National Center for Environmental Assessment (NCEA), for the Integrated Risk Information System (IRIS). A panel of external peer reviewers met to discuss their responses to the charge questions on July 30, 2004. This document contains the final written comments of the external peer reviewers.

  2. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) ...

    EPA Pesticide Factsheets

    The IRIS Toxicological Review of tert-Butyl Alcohol (tert-Butanol) was released for external peer review in June 2017. EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the tert-butanol assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is conducting an Integrated Risk Information System (IRIS) health assessment for tert-butanol. The outcome of this project is a Toxicological Review and IRIS Summary for tert-butanol that will be entered into the IRIS database.

  3. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl ...

    EPA Pesticide Factsheets

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of ethylene glycol monobutyl ether that will appear on the Integrated Risk Information System (IRIS) database. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of propionaldehyde that will appear on the Integrated Risk Information System (IRIS) database.

  4. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (Etbe) ...

    EPA Pesticide Factsheets

    The IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) was released for external peer review in June 2017. EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the ETBE assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is conducting an Integrated Risk Information System (IRIS) health assessment for Ethyl Tertiary Butyl Ether (ETBE). The outcome of this project is a Toxicological Review and IRIS Summary for ETBE that will be entered into the IRIS database.

  5. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    EPA Pesticide Factsheets

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the RDX assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  6. IRIS Toxicological Review of Hexavalent Chromium (Peer Review Plan)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hexavalent chromium that will appear on the Integrated Risk Information System (IRIS) database.

  7. IRIS Toxicological Review of 2,2',4,4'-Tetrabromodiphenyl ...

    EPA Pesticide Factsheets

    The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about 2,2',4,4'-Tetrabromodiphenyl Ether, or commonly referred to as tetraBDE (BDE-47). Following the external peer review this assessment will appear in the Integrated Risk Information System (IRIS) database. Peer review will ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. EPA is updating the Integrated Risk Information System (IRIS) health assessments for the PBDEs.

  8. IRIS Toxicological Review of Methanol (Non-Cancer) ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that will appear in the Integrated Risk Information System (IRIS) database.

  9. EPA Peer Consultation Workshop Report on the Review of the Draft IRIS Toxicological Review of Dibutyl Phthalate (DBP)

    EPA Science Inventory

    The U.S. EPA finalized comments gathered from a public peer review of the scientific basis supporting the human health hazard and dose-response assessment of dibutyl phthalate (DBP) that will appear on the Integrated Risk Information System (IRIS) database. The peer review has en...

  10. IRIS Toxicological Review and Summary Documents for 1,4-Dichlorobenzene (External Peer Review)

    EPA Science Inventory

    The U.S. EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-dichlorobenzene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used ...

  11. IRIS Toxicological Review of Carbon Tetrachloride (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of carbon tetrachloride that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and...

  12. IRIS Toxicological Review of Bromobenzene (External Review Draft)

    EPA Science Inventory

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of Bromobenzene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and app...

  13. IRIS Toxicological Review of Acrylamide (External Review Draft)

    EPA Science Inventory

    EPA has conducted a peer review by EPA’s Science Advisory Board (SAB) of the scientific basis supporting the human health hazard and dose-response assessment of acrylamide that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is m...

  14. IRIS Toxicological Review of Tetrachloroethylene (Perchloroethylene) (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of tetrachloroethylene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and ...

  15. IRIS Toxicological Review of Nitrobenzene (External Review Draft)

    EPA Science Inventory

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessments of nitrobenzene, that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and a...

  16. IRIS Toxicological Review of 2-Hexanone (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2-hexanone that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appro...

  17. IRIS Toxicological Review of Dibutyl Phthalate (DBP) (External Review Draft) 2006

    EPA Science Inventory

    The U.S. EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of dibutyl phthalate that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used cr...

  18. IRIS Toxicological Review of 1,2,3-Trichloropropane (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,2,3-trichloropropane (TCP) that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that scie...

  19. IRIS Toxicological Review of Biphenyl (Interagency Science ...

    EPA Pesticide Factsheets

    On September 30, 2011, the draft Toxicological Review of Biphenyl and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Biphenyl and the charge to external peer reviewers are posted on this site. EPA is undertaking a new health assessment for biphenyl for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS and IRIS Summary of biohenyl that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information to evaluate potential public health risks associated with exposure assessment information to evaluate potential public health risks associated with environmental contaminants. The IRIS database is relied on for the development of risk ass

  20. IRIS Toxicological Review of Benzo[a]pyrene (Public ...

    EPA Pesticide Factsheets

    EPA is developing an Integrated Risk Information System (IRIS) assessment of benzo[a]pyrene and has released the draft assessment for public comment and external peer review. When final, the assessment will appear on the IRIS database. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  1. IRIS Toxicological Review of Benzo[a]pyrene (Public Comment Draft)

    EPA Science Inventory

    EPA is developing an Integrated Risk Information System (IRIS) assessment of benzo[a]pyrene and has released the draft assessment for public comment and external peer review. When final, the assessment will appear on the IRIS database.

  2. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR BORON AND COMPOUNDS (THIRD EXTERNAL REVIEW DRAFT 2002)

    EPA Science Inventory

    The U. S. EPA has conducted a peer review of the scientific basis supporting the health hazard and dose response assessment for Boron that will appear on the Agency's online data base, the Integrated Risk Information System (IRIS). Peer Review is meant to ensure that science is u...

  3. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 2,2,4-TRIMETHYLPENTANE (EXTERNAL REVIEW DRAFT)

    EPA Science Inventory

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2,2,4-trimethylpentane, also called TMP, that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that scie...

  4. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 1,1,1-TRICHLOROETHANE (EXTERNAL REVIEW DRAFT)

    EPA Science Inventory

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,1,1-trichloroethane that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibl...

  5. IRIS Toxicological Review of Ammonia (Interagency Science ...

    EPA Pesticide Factsheets

    On June 1, 2012, the draft Toxicological Review of Ammonia and the draft charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Ammonia and the charge to external peer reviewers, are posted on this site. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  6. IRIS Toxicological Review for Carbon Tetrachloride ...

    EPA Pesticide Factsheets

    EPA released the draft report,Toxicological Review for Carbon Tetrachloride(Interagency Science Discussion Draft), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of carbon tetrachloride that will appear on the Integrated Risk Information System (IRIS) database.

  7. IRIS Toxicological Review of 2-Hexanone (External Review ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2-hexanone that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. 2-Hexanone was nominated for IRIS assessment because of its frequent detection at sites nation-wide and its occurrence as a byproduct of certain industrial processes.

  8. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl ...

    EPA Pesticide Factsheets

    EPA released the draft report, Toxicological Review for Ethylene Glycol Mono-Butyl Ether , that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of EGBE that will appear on the Integrated Risk Information System (IRIS) database.

  9. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of 1,2,3-trichloropropane (TCP) was added to the IRIS database in 1990. The IRIS program is updating the IRIS assessment for TCP. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for TCP will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of TCP (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of TCP. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for 1,2,3-trichloropropane. IRIS is an EPA database containing the Agency's consensus scientific positions on potential adverse human effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in

  10. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    EPA Pesticide Factsheets

    On August 21, 2013, the draft Toxicological Review of Benzo[a]pyrene and the draft charge to external peer reviewers were released for public review and comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene and the charge to external peer reviewers, are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  11. IRIS Toxicological Review and Summary Documents for N ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of n-hexane was last prepared and added to the IRIS data base in 1990. The IRIS program is updating the IRIS assessment for n-hexane; this update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for n-hexane will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of n-hexane (RfD and RfC) and a cancer assessment, where supported by available data. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for n-hexane. The outcome of this project is an updated Toxicological Review and IRIS Summary for n-Hexane that will be entered into the IRIS database. IRIS is an EPA data base containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment

  12. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) (Public Comment Draft)

    EPA Science Inventory

    EPA is developing an Integrated Risk Information System (IRIS) assessment of tert-butyl Alcohol (tert-butanol) and has released the public comment draft assessment for public comment and external peer review. When final, the assessment will appear on the IRIS databa...

  13. IRIS Toxicological Review of Propionaldehyde (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of propionaldehyde that will appear on the Integrated Risk Information System (IRIS) database.

  14. IRIS Toxicological Review of Chloroprene (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of chloroprene that will appear on the Integrated Risk Information System (IRIS) database.

  15. IRIS Toxicological Review of Chloroprene (2000 External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of chloroprene that will appear on the Integrated Risk Information System (IRIS) database.

  16. IRIS Toxicological Review of Trimethylbenzenes (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of trimethylbenzenes that will appear in the Integrated Risk Information System (IRIS) database.

  17. IRIS Toxicological Review of Ammonia (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of ammonia that will appear in the Integrated Risk Information System (IRIS) database.

  18. IRIS Toxicological Review of Pentachlorophenol (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of pentachlorophenol that will appear in the Integrated Risk Information System (IRIS) database.

  19. IRIS Toxicological Review of Ammonia (Revised External ...

    EPA Pesticide Factsheets

    In August 2013, EPA submitted a revised draft IRIS assessment of ammonia to the agency's Science Advisory Board (SAB) and posted this draft on the IRIS website. EPA had previously released a draft of the assessment for public comment, held a public meeting about the draft, and then revised it based on the comments received. The SAB CAAC-Ammonia panel will review this draft assessment. Details about the meeting dates, times, and location are available via the Federal Register Notice posted on March 25, 2014. The SAB provided information on how the public can participate in the external peer review meetings, as well as instructions about how to provide comments to the SAB in the notice. Additional information on the SAB review of ammonia is on the SAB website. Report Information: The Toxicological Review of Ammonia was originally released for a 60-day public comment period on June 8, 2012. [Federal Register Notice Jun 8, 2012] EPA revised the toxicological review in response to the public comments received. EPA has released the revised external review draft ammonia assessment and the SAB CAAC is conducting a peer review of the scientific basis supporting the assessment that will appear in the Integrated Risk Information System (IRIS) database. Information regarding the peer review can be found at the SAB review of ammonia website. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database cont

  20. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    EPA Pesticide Factsheets

    On March 10, 2016, the public comment draft Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine and the draft charge to external peer reviewers were released for public review and comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine and the charge to external peer reviewers, are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  1. IRIS Toxicological Review of Biphenyl (External Review Draft) (September 2011)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of biphenyl that will appear in the Integrated Risk Information System (IRIS) database.

  2. IRIS Toxicological Review of n-Butanol (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of n-butanol that will appear in the Integrated Risk Information System (IRIS) database.

  3. IRIS Toxicological Review of Hexachloroethane (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of hexachloroethane that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  4. IRIS Toxicological Review of Libby Amphibole Asbestos (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of Libby Amphibole Asbestos that will appear in the Integrated Risk Information System (IRIS) database.

  5. IRIS Toxicological Review of Hydrogen Cyanide (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hydrogen cyanide and cyanide salts that will appear on the Integrated Risk Information System (IRIS) database.

  6. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Dichloromethane that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  7. IRIS Toxicological Review of Tetrahydrofuran (THF) (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of tetrahydrofuran (THF) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  8. IRIS Toxicological Review of Trichloroethylene (TCE) (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroethylene (TCE) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  9. IRIS Toxicological Review of Cerium Oxide and Cerium Compounds (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of cerium oxide and cerium compounds that will appear on the Integrated Risk Information System (IRIS) database.

  10. IRIS Toxicological Review of Tetrachloroethylene ...

    EPA Pesticide Factsheets

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of tetrachloroethylene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the toxicological characterization and dose-response assessments. This draft health assessment addresses both non-cancer and cancer human health effects that may result from chronic exposure to tetrachloroethylene (also called Perchloroethylene or Perc) . This is an update of an existing assessment posted on IRIS in 1988. This draft Toxicological Review includes a chronic Reference Concentration (RfC) and carcinogenicity assessment, which are not currently available on IRIS, as well as an update of the 1988 IRIS Reference Dose (RfD). Tetrachloroethylene is a chemical solvent that is widely used for dry cleaning of fabrics, metal degreasing, and in making some consumer products and other chemicals.

  11. IRIS Toxicological Review of Libby Amphibole Asbestos ...

    EPA Pesticide Factsheets

    On August 25, 2011, the draft Toxicological Review of Libby Amphibole Asbestos and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Libby Amphibole Asbestos and the charge to external peer reviewers are posted on this site. The project supports OSWER and Region 8 site clean-up and related risk management initiatives at this Superfund site. As with all IRIS assessments, the draft document will undergo agency review, OMB/interagency review and independent external peer review before being included on the IRIS data base.

  12. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of Beryllium was added to the IRIS database in 1998. The IRIS program is updating the IRIS assessment for Beryllium. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for Beryllium will consist of an updated Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of Beryllium (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency and Interagency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of Beryllium. Beryllium is a light alkaline earth metal used in metal alloys and in high-performance products in the metallurgical, aerospace, and nuclear industries. According to the Superfund database, beryllium is found in over 300 NPL sites

  13. IRIS Toxicological Review of Methanol (External Review Draft, 2013)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  14. IRIS Toxicological Review of Urea (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review and public comment of the scientific basis of a draft report supporting the human health hazard and dose-response assessment of Urea that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  15. IRIS Toxicological Review of Trichloroacetic Acid (TCA) (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  16. IRIS Toxicological Review of 1,1,2,2-Tetrachloroethane (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,1,2,2-tetrachloroethane that will appear on the Integrated Risk Information System (IRIS) database.

  17. IRIS Toxicological Review of Cis-& Trans-1,2-Dichloroethylene (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of cis- and trans-1,2-dichloroethylene that will appear in the Integrated Risk Information System (IRIS) database.

  18. IRIS Toxicological Review of Formaldehyde (Inhalation) (External Review Draft 2010)

    EPA Science Inventory

    UPDATE EPA is currently revising its Integrated Risk Information System (IRIS) assessment of formaldehyde to address the 2011 NAS peer review recommendations. This assessment addresses both noncancer and cancer human health effects that are relevant to assessing ...

  19. IRIS Toxicological Review of Beryllium and Compounds (2008 External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Beryllium that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  20. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl Ether (Egbe) (External Review Draft)

    EPA Science Inventory

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of ethylene glycol monobutyl ether that will appear on the Integrated Risk Information System (IRIS) database.

  1. IRIS Toxicological Review of n-Butanol (Interagency Science ...

    EPA Pesticide Factsheets

    On September 8, 2011, the Toxicological Review of n-Butanol (External Review Draft) was released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation draft of the IRIS Toxicological Review of n-Butanol and the charge to external peer reviewers are posted on this site. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  2. IRIS Toxicological Review of 1,4-Dioxane (External Review Draft, 2009)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-dioxane that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  3. IRIS Toxicological Review of Methanol (Non-Cancer) (External Review Draft; April 2011)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  4. IRIS Toxicological Review of Ammonia (External Review Draft ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of ammonia that will appear in the Integrated Risk Information System (IRIS) database. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  5. IRIS Toxicological Review of n-Butanol (External Review Draft ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of n-butanol that will appear in the Integrated Risk Information System (IRIS) database. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  6. IRIS Toxicological Review of 1,2,3-Trichloropropane (External ...

    EPA Pesticide Factsheets

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,2,3-trichloropropane (TCP) that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. This Tox Review provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to 1,2,3-trichloropropane.

  7. IRIS Toxicological Review of 1,4-Dioxane (with Inhalation Update) (External Review Draft)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-Dioxane (with inhalation update) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  8. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (External Review Draft, 2009)

    EPA Science Inventory

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of ethyl tertiary butyl ether (ETBE) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  9. IRIS Toxicological Review of Tetrahydrofuran (THF) (External ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of tetrahydrofuran (THF) that when finalized will appear on the Integrated Risk Information System (IRIS) database. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for tetrahydrofuran. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  10. IRIS Toxicological Review of Inorganic Arsenic (Cancer) ...

    EPA Pesticide Factsheets

    On February 19, 2010, the draft IRIS Toxicological Review of Inorganic Arsenic (Cancer) external review draft document and the charge to external peer reviewers were released for public review and comment. The draft document and the charge to external peer reviewers were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the Toxicological Review of Inorganic Arsenic and the charge to external peer reviewers are posted on this site. This draft IRIS health assessment addresses only cancer human health effects that may result from chronic exposure to this chemical. An assessment of noncancer health effects of inorganic arsenic will be released for external peer review and public comment at a later date.

  11. IRIS Toxicological Review of Beryllium and Compounds (2008 ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Beryllium that when finalized will appear on the Integrated Risk Information System (IRIS) database. An IRIS Toxicological Review of Beryllium and Compounds was published in 1988 and reassessed in 1998. The current draft (2007) only focuses on the cancer assessment and does not re-evaluate posted reference doses or reference concentrations.

  12. IRIS Toxicological Review of Acrylamide (External Review ...

    EPA Pesticide Factsheets

    EPA has conducted a peer review by EPA’s Science Advisory Board (SAB) of the scientific basis supporting the human health hazard and dose-response assessment of acrylamide that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that the science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. The draft Toxicological Review of Acrylamide provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to a chronic exposure to acrylamide.

  13. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    Trichloroacetic acid is a crystalline solid with sharp, pungent odor. It is used as a soil sterilizer; and as a laboratory intermediate or reagent in the synthesis of a variety of medicinal products and organic chemicals. Trichloroacetic acid is also used industrially as an etching and pickling agent for the surface treatment of metals and as a solvent in the plastics industry. Trichloroacetic acid can be formed as a combustion byproduct of organic compounds in the presence of chlorine. It is also formed as a disinfection byproduct during water chlorination. The existing IRIS entry was added to the IRIS data base between 1994 and 1996. No RfD was developed. The IRIS program is updating the IRIS assessment for Trichloroacetic Acid. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for Trichloroacetic Acid will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference value for noncancer effects of Trichloroacetic Acid (RfD) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review and external scientific peer review. The final products will constitute the Agency's opinion on the

  14. Provisional Peer-Reviewed Toxicity Values for Acenaphthene

    EPA Science Inventory

    A Provisional Peer-Reviewed Toxicity Values (PPRTV) is defined as a toxicity value derived for use in the Superfund Program when such a value is not available from EPA’s Integrated Risk Information System (IRIS) Database. PPRTVs are developed according to a Standard Operating Pr...

  15. IRIS Toxicological Review of Dichloromethane (Methylene ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Dichloromethane that when finalized will appear on the Integrated Risk Information System (IRIS) database. The draft Toxicological Review of Dichloromethane provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to dichloromethane.

  16. IRIS Toxicological Review of Trichloroethylene (TCE) ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroethylene (TCE) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The purpose of this Toxicological Review is to provide scientific support and rationale for the hazard and dose-response assessment in IRIS pertaining to chronic exposure to trichloroethylene. It is not intended to be a comprehensive treatise on the chemical or toxicological nature of trichloroethylene.

  17. Peer Review Comments on the IRIS Assessment of Benzene

    EPA Pesticide Factsheets

    Attachment to IRIS file for benzene, January 19, 2000, RESPONSE TO THE PEER REVIEW COMMENTS, II. Extrapolation of the Benzene Inhalation Unit Risk Estimate to the Oral Route of Exposure (EPA/NCEA-W-0517, July 1999)

  18. IRIS Toxicological Review of Formaldehyde (Inhalation) ...

    EPA Pesticide Factsheets

    UPDATE EPA is currently revising its Integrated Risk Information System (IRIS) assessment of formaldehyde to address the 2011 NAS peer review recommendations. This assessment addresses both noncancer and cancer human health effects that are relevant to assessing the risks from chronic inhalation exposure to formaldehyde. To facilitate discussion of several scientific issues pertinent to the assessment, EPA convened a state-of-the-science workshop on April 30 and May 1, 2014. This workshop focused on the following three themes: Evidence pertaining to the influence of formaldehyde that is produced endogenously (by the body during normal biological processes) on the toxicity of inhaled formaldehyde, and implications for the health assessment; Mechanistic evidence relevant to formaldehyde inhalation exposure and lymphohematopoietic cancers (leukemia and lymphomas); and Epidemiological research examining the potential association between formaldehyde exposure and lymphohematopoietic cancers (leukemia and lymphomas). June 2010: EPA is conducting an independent expert peer review by the National Academy of Sciences and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Formaldehyde-Inhalation that when finalized will appear on the Integrated Risk Information System (IRIS) database. This draft IRIS health assessment addresses both noncancer and cancer human health effects that may result from chronic inhal

  19. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (Etbe) ...

    EPA Pesticide Factsheets

    In September 2016, the U.S. Environmental Protection Agency's (USEPA) released the draft Integrated Risk Information System (IRIS) Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE). Consistent with the 2013 IRIS Enhancements, draft IRIS assessments are released prior to external peer review for a 60-day public comment period and discussed at an upcoming public science meeting. Accordingly, the toxicological review, supplementary information, and other materials pertaining to this draft assessment are posted on this site. This material is being released for public viewing and comment prior to a public meeting, providing an opportunity for the IRIS Program to engage in early discussions with stakeholders and the public on data that may be used to identify adverse health effects and characterize exposure-response relationships.

  20. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    EPA Pesticide Factsheets

    On September 24, 2009, the Toxicological Review of Trichloroacetic Acid (TCA) and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Trichloroacetic Acid and the charge to external peer reviewers are posted on this site. The draft Toxicological Review of Trichloroacetic Acid provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  1. IRIS Toxicological Review of Formaldehyde (Interagency ...

    EPA Pesticide Factsheets

    On June 2, 2010, the Toxicological Review of Formaldehyde and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Formaldehyde and the charge to external peer reviewers are posted on this site. The draft Toxicological Review of Formaldehyde-Inhalation Assessment provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic inhalation exposure to formaldehyde.

  2. IRIS Toxicological Review of Urea (Interagency Science ...

    EPA Pesticide Factsheets

    On September 28, 2010, the Toxicological Review of Urea and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Urea and the charge to external peer reviewers are posted on this site. The draft Toxicological Review of Urea provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to Urea.

  3. IRIS Toxicological Review of Tetrahydrofuran (THF) ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, Toxicological Review of Tetrahydrofuran, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for tetrahydrofuran. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  4. IRIS Toxicological Review of Mirex (2003 External Review Draft)

    EPA Science Inventory

    EPA is providing for public information a draft Toxicological Review, draft IRIS Summary, and charge to external peer reviewers for EPA's Health Assessment of Mirex. These documents are provided for public viewing during an external scientific peer review period. While EPA is not...

  5. IRIS Toxicological Review of Urea (External Review Draft) ...

    EPA Pesticide Factsheets

    EPA conducted a peer review and public comment of the scientific basis of a draft report supporting the human health hazard and dose-response assessment of Urea that when finalized will appear on the Integrated Risk Information System (IRIS) database. The draft Toxicological Review of Urea provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to Urea.

  6. IRIS Toxicological Review of 1,4-Dioxane (with Inhalation ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-Dioxane (with inhalation update) that when finalized will appear on the Integrated Risk Information System (IRIS) database. 1,4-Dioxane is commonly used as a solvent, cleaning agent, chemical stabilizer, surface coating, adhesive agent, and an ingredient in chemical manufacture.

  7. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    EPA Pesticide Factsheets

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The draft Toxicological Review of trichloroacetic acid provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  8. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 1,1,1-TRICHLOROETHANE (PEER REVIEW PLAN)

    EPA Science Inventory

    EPA's assessment of the carcinogenic potential of 1,1,1-trichloroethane was entered into the IRIS database in 1988, and the assessment of noncancer effects following oral exposure was withdrawn from IRIS in 1991. The IRIS program prepared an update of the IRIS assessment for 1,1,...

  9. IRIS Toxicological Review of Benzo[a]pyrene (External Review Draft)

    EPA Science Inventory

    The IRIS Toxicological Review of Benzo[a]pyrene was released for external peer review in September 2014. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) conducted a peer review of the scientific basis supporting the benzo[a]pyrene assessmen...

  10. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (Interagency Science Consultation Draft)

    EPA Science Inventory

    On March 31, 2010, the draft IRIS Toxicological Review of Dichloromethane (Methylene Chloride) external review draft document and the charge to external peer reviewers were released for public review and comment. The draft document and the charge to external peer reviewers were r...

  11. IRIS Toxicological Review of Inorganic Arsenic (Cancer) (Interagency Science Consultation Draft)

    EPA Science Inventory

    On February 19, 2010, the draft IRIS Toxicological Review of Inorganic Arsenic (Cancer) external review draft document and the charge to external peer reviewers were released for public review and comment. The draft document and the charge to external peer reviewers were reviewed...

  12. IRIS Toxicological Review of Dichloromethane (Methylene ...

    EPA Pesticide Factsheets

    On March 31, 2010, the draft IRIS Toxicological Review of Dichloromethane (Methylene Chloride) external review draft document and the charge to external peer reviewers were released for public review and comment. The draft document and the charge to external peer reviewers were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the Toxicological Review of Dichloromethane (Methylene Chloride) and the charge to external peer reviewers are posted on this site. The draft Toxicological Review of Dichloromethane provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to dichloromethane.

  13. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) (External Review Draft)

    EPA Science Inventory

    The IRIS Toxicological Review of tert-Butyl Alcohol (tert-Butanol) was released for external peer review in June 2017. EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting ...

  14. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (External Review Draft)

    EPA Science Inventory

    The IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) was released for external peer review in June 2017. EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the ETB...

  15. Final Report from the External Peer Review of the IRIS Reassessment of the Inhalation Carcinogenicity of Naphthalene

    EPA Science Inventory

    This document is the final report for the 2004 external peer review for the EPA IRIS Reassessment of the Inhalation Carcinogenicity of Naphthalene, prepared by the Office of Research and Development's National Center for Environmental Assessment (NCEA), for the Integrated ...

  16. Evaluation of the Inhalation Carcinogenicity of Ethylene Oxide ...

    EPA Pesticide Factsheets

    EPA is seeking peer review of the scientific basis supporting the human health hazard and dose-response assessment of ethylene oxide (cancer) that will appear in the Integrated Risk Information System (IRIS) database. EPA seeks external peer review on how the Agency responded to the SAB panel recommendations, the exposure-response modeling of epidemiologic data, including new analyses since the 2007 external peer review, and on the adequacy, transparency, and clarity of the revised draft. The peer review will include an opportunity for the public to address the peer reviewers.

  17. IRIS Toxicological Review of Vanadium Pentoxide ...

    EPA Pesticide Factsheets

    On September 30, 2011, the draft Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers are posted on this site. EPA is reassessing its IRIS toxicological review of vanadium pentoxide (CASRN 1314-62-1). This vanadium pentoxide reassessment consists of an oral reference dose (RfD), an inhalation reference concentration (RfC), an inhalation unit risk (IUR) and a cancer weight of evidence descriptor. This is the first assessment developing an RfC or IUR for this compound. This assessment is intended to provide human health data to support agency regulatory decisions.

  18. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (External Review Draft)

    EPA Science Inventory

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis suppor...

  19. IRIS Toxicological Review of Thallium and Compounds ...

    EPA Pesticide Factsheets

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  20. Evaluation of the Inhalation Carcinogenicity of Ethylene Oxide ...

    EPA Pesticide Factsheets

    EPA is initiating a public comment period prior to peer review of the scientific basis supporting the human health hazard and dose-response assessment of ethylene oxide (cancer) that will appear in the Integrated Risk Information System (IRIS) database. EPA seeks external peer review on how the Agency responded to the SAB panel recommendations, the exposure-response modeling of epidemiologic data, including new analyses since the 2007 external peer review, and on the adequacy, transparency, and clarity of the revised draft. The peer review will include an opportunity for the public to address the peer reviewers.

  1. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) ...

    EPA Pesticide Factsheets

    On April 29, 2016, the Toxicological Review of tert-Butyl Alcohol (tert-Butanol) (Public Comment Draft) was released for public comment. The draft Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and the Executive Office of the President during Step 3 (Interagency Science Consultation) before public release. As part of the IRIS process, all written interagency comments on IRIS assessments will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation drafts of the IRIS Toxicological Review of tert-Butanol and charge to external peer reviewers are posted on this site. EPA is undertaking a new health assessment for t-butyl alcohol (tert-butanol) for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS and IRIS Summary of TBA that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information to evaluate potential public health risks associated with environmental contaminants. The IRIS database is relied on for the development of risk assessments, site-specific environmental decisions, and rule making.

  2. IRIS Toxicological Review of 2-Hexanone (Interagency Science Discussion Draft)

    EPA Science Inventory

    On September 25, 2009, the IRIS Summary and Toxicological Review of 2-hexanone was finalized and loaded onto the IRIS database. The Toxicological Review of 2-hexanone was reviewed internally by EPA, by other federal agencies and White House Offices, by expert external peer revie...

  3. IRIS Toxicological Review of Hexavalent Chromium (2010 External Review Draft)

    EPA Science Inventory

  1. IRIS Toxicological Review of Trimethylbenzenes (Interagency Science Consultation Draft)

    EPA Science Inventory

    On June 26, 2012, the draft Toxicological Review of Trimethylbenzenes and the draft charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and W...

  2. IRIS Toxicological Review of Trichloroethylene (Interagency Science Consultation Draft)

    EPA Science Inventory

    On November 3, 2009, the Toxicological Review of Trichloroethylene and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White Hous...

  3. IRIS Toxicological Review of Formaldehyde (Interagency Science Consultation Draft)

    EPA Science Inventory

    On June 2, 2010, the Toxicological Review of Formaldehyde and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices...

  4. IRIS Toxicological Review of Biphenyl (Interagency Science Consultation Draft)

    EPA Science Inventory

    On September 30, 2011, the draft Toxicological Review of Biphenyl and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House...

  5. IRIS Toxicological Review of Acrylonitrile (Interagency Science Consultation Draft)

    EPA Science Inventory

    On June 30, 2011, the draft Toxicological Review of Acrylonitrile and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House...

  6. Six years after the NRC review of EPA's Draft IRIS Toxicological Review of Formaldehyde: Regulatory implications of new science in evaluating formaldehyde leukemogenicity.

    PubMed

    Mundt, Kenneth A; Gentry, P Robinan; Dell, Linda D; Rodricks, Joseph V; Boffetta, Paolo

    2018-02-01

    Shortly after the International Agency for Research on Cancer (IARC) determined that formaldehyde causes leukemia, the United States Environmental Protection Agency (EPA) released its Draft IRIS Toxicological Review of Formaldehyde ("Draft IRIS Assessment"), also concluding that formaldehyde causes leukemia. Peer review of the Draft IRIS Assessment by a National Academy of Science committee noted that "causal determinations are not supported by the narrative provided in the draft" (NRC 2011). They offered recommendations for improving the Draft IRIS assessment and identified several important research gaps. Over the six years since the NRC peer review, significant new science has been published. We identify and summarize key recommendations made by NRC and map them to this new science, including extended analysis of epidemiological studies, updates of earlier occupational cohort studies, toxicological experiments using a sensitive mouse strain, mechanistic studies examining the role of exogenous versus endogenous formaldehyde in bone marrow, and several critical reviews. With few exceptions, new findings are consistently negative, and integration of all available evidence challenges the earlier conclusions that formaldehyde causes leukemia. Given formaldehyde's commercial importance, environmental ubiquity and endogenous production, accurate hazard classification and risk evaluation of whether exposure to formaldehyde from occupational, residential and consumer products causes leukemia are critical. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. IRIS TOXICOLOGICAL REVIEW OF HEXAVALENT CHROMIUM (INTERAGENCY SCIENCE CONSULTATION DRAFT)

    EPA Science Inventory

    On Septemeber 30, 2010, the draft Toxicological Review of Hexavalent Chromium and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agenc...

  8. IRIS Toxicological Review of Libby Amphibole Asbestos (Interagency Science Consultation Draft)

    EPA Science Inventory

    On August 25, 2011, the draft Toxicological Review of Libby Amphibole Asbestos and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies an...

  9. IRIS Toxicological Review of Urea (Interagency Science Consultation Draft)

    EPA Science Inventory

    On September 28, 2010, the Toxicological Review of Urea and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Of...

  10. IRIS Toxicological Review of Ammonia (Interagency Science Consultation Draft)

    EPA Science Inventory

    On June 1, 2012, the draft Toxicological Review of Ammonia and the draft charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House ...

  11. IRIS Toxicological Review of Vanadium Pentoxide (Interagency Science Consultation Draft)

    EPA Science Inventory

    On September 30, 2011, the draft Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and W...

  12. IRIS Toxicological Review of cis- & trans-1,2-Dichloroethylene (Interagency Science Consultation Draft)

    EPA Science Inventory

    On September 24, 2009, the Toxicological Review of cis- and trans-1,2-dichloroethylene and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal ag...

  13. IRIS Toxicological Review of Libby Amphibole Asbestos (Interagency Science Discussion Draft)

    EPA Science Inventory

    On August 25, 2011, the draft assessment of Libby Amphibole asbestos was released for external peer review and public comment. The draft assessment was revised based on peer review comments from EPA’s Science Advisory Board (SAB) and public comments. The revised draft was review...

  14. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR POLYBROMINATED DIPHENYL ETHERS (EXTERNAL PEER REVIEW)

    EPA Science Inventory

    The U.S. EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessments of four congeners of polybrominated diphenyl ethers: tetraBDE (BDE-47), pentaBDE (BDE-99), hexaBDE (BDE-153), and decaBDE (BDE-209), that will appear on ...

  15. IRIS Toxicological Review of Dichloromethane (Methylene ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, Toxicological Review of Dichloromethane, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The draft Toxicological Review of Dichloromethane provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to dichloromethane.

  16. IRIS Toxicological Review of Urea (Interagency Science ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, Toxicological Review of Urea,, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The draft Toxicological Review of Urea provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to Urea.

  17. Toward Webscale, Rule-Based Inference on the Semantic Web Via Data Parallelism

    DTIC Science & Technology

    2013-02-01

    Another work distinct from its peers is the work on approximate reasoning by Rudolph et al. [34] in which multiple inference sys- tems were combined not...Workshop Scalable Semantic Web Knowledge Base Systems, 2010, pp. 17–31. [34] S. Rudolph , T. Tserendorj, and P. Hitzler, “What is approximate reasoning...2013] [55] M. Duerst and M. Suignard. (2005, Jan .). RFC 3987 – internationalized resource identifiers (IRIs). IETF. [Online]. Available: http

  18. The need for transparency and reproducibility in documenting values for regulatory decision making and evaluating causality: The example of formaldehyde.

    PubMed

    Van Landingham, Cynthia; Mundt, Kenneth A; Allen, Bruce C; Gentry, P Robinan

    2016-11-01

    Reproducibility and transparency in scientific reporting is paramount to advancing science and providing the foundation required for sound regulation. Recent examples demonstrate that pivotal scientific findings cannot be replicated, due to poor documentation or methodological bias, sparking debate across scientific and regulatory communities. However, there is general agreement that improvements in communicating and documenting research and risk assessment methods are needed. In the case of formaldehyde, the peer-review conducted by a National Academy of Sciences (NAS) Committee questioned the approaches used by the Integrated Risk Information System (IRIS) in developing draft unit risk values. Using the original data from the key study (Beane Freeman et al., 2009) and documentation provided in the draft IRIS profile, we attempted to duplicate the reported inhalation unit risk values and address the NAS Committee's questions regarding application of the appropriate dose-response model. Overall, documentation of the methods lacked sufficient detail to allow for replication of the unit risk estimates, specifically for Hodgkin lymphoma and leukemias, the key systemic endpoints selected by IRIS. The lack of apparent exposure-response relationships for selected endpoints raises the question whether quantitative analyses are appropriate for these endpoints, and if so, how results are to be interpreted. Copyright © 2016. Published by Elsevier Inc.

  19. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, Toxicological Review of Trichloroacetic Acid (TCA), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The draft Toxicological Review of Trichloroacetic Acid provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  20. NASA's IRIS Observed a Gigantic Eruption on the Sun!

    NASA Image and Video Library

    2014-05-30

    A coronal mass ejection, or CME, surged off the side of the sun on May 9, 2014, and NASA's newest solar observatory caught it in extraordinary detail. This was the first CME observed by the Interface Region Imaging Spectrograph, or IRIS, which launched in June 2013 to peer into the lowest levels of the sun's atmosphere with better resolution than ever before. Watch the movie to see how a curtain of solar material erupts outward at speeds of 1.5 million miles per hour. Read more: 1.usa.gov/1kp7O4F Credit: NASA's Goddard Space Flight Center NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  1. IRIS Toxicological Review of 1,1,2,2-Tetrachloroethane ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, Toxicological Review of 1,1,2,2-Tetrachloroethane, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The draft Toxicological Review of 1,1,2,2-Tetrachloroethane provides scientific support and rationale for the hazard and dose-response assessment pertaining to subchronic and chronic exposure to 1,1,2,2-Tetrachloroethane.

  2. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    Cerium is a member of the lanthanoid series of rare earth metals. It is also the most abundant and most reactive of the rare earth metals. Cerium oxidizes at room temperature and forms a variety of salt compounds including oxides, hydroxides, sulfates and chlorides. Cerium is used in a variety of ways and is present in many products. For example, cerium is used as a catalyst in emission control systems for gasoline engines, and most recently, as a fuel borne catalyst for diesel engines. In addition, cerium is found in carbon arc lamps, the polishing of lens and mirrors, high temperature ceramics, and the printing and lithographic industries. Cerium is released to the environment as salt compounds from the various uses listed above. This assessment will present reference values for the noncancer effects (RfD and RfC), where supported by the available data, and a cancer evaluation of cerium and cerium compounds. The assessment will be subject to internal review and external peer review along with Agency review. The final product will reflect the Agency's opinion on the toxicity of Cerium and cerium compounds. The U.S. EPA is conducting a new health assessment of cerium (stable) and compounds that will appear on the Agency's online database, the Integrated Risk Information System (IRIS). IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals i

  3. Iris segmentation using an edge detector based on fuzzy sets theory and cellular learning automata.

    PubMed

    Ghanizadeh, Afshin; Abarghouei, Amir Atapour; Sinaie, Saman; Saad, Puteh; Shamsuddin, Siti Mariyam

    2011-07-01

    Iris-based biometric systems identify individuals based on the characteristics of their iris, since they are proven to remain unique for a long time. An iris recognition system includes four phases, the most important of which is preprocessing in which the iris segmentation is performed. The accuracy of an iris biometric system critically depends on the segmentation system. In this paper, an iris segmentation system using edge detection techniques and Hough transforms is presented. The newly proposed edge detection system enhances the performance of the segmentation in a way that it performs much more efficiently than the other conventional iris segmentation methods.

  4. IRIS Toxicological Review of Methanol (Noncancer) (Revised External Review Draft)

    EPA Science Inventory

    EPA is seeking additional public comment and external peer review of the scientific basis supporting the human health hazard and dose-response assessment of methanol (noncancer).

  1. IRIS Toxicological Review of Benzo[a]pyrene (Interagency Science Consultation Draft)

    EPA Science Inventory

    On August 21, 2013, the draft Toxicological Review of Benzo[a]pyrene and the draft charge to external peer reviewers were released for public review and comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offi...

  2. A gallery approach for off-angle iris recognition

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher

    2015-05-01

    It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.

  3. On techniques for angle compensation in nonideal iris recognition.

    PubMed

    Schuckers, Stephanie A C; Schmid, Natalia A; Abhyankar, Aditya; Dorairaj, Vivekanand; Boyce, Christopher K; Hornak, Lawrence A

    2007-10-01

    The popularity of the iris biometric has grown considerably over the past two to three years. Most research has been focused on the development of new iris processing and recognition algorithms for frontal view iris images. However, a few challenging directions in iris research have been identified, including processing of a nonideal iris and iris at a distance. In this paper, we describe two nonideal iris recognition systems and analyze their performance. The word "nonideal" is used in the sense of compensating for off-angle occluded iris images. The system is designed to process nonideal iris images in two steps: 1) compensation for off-angle gaze direction and 2) processing and encoding of the rotated iris image. Two approaches are presented to account for angular variations in the iris images. In the first approach, we use Daugman's integrodifferential operator as an objective function to estimate the gaze direction. After the angle is estimated, the off-angle iris image undergoes geometric transformations involving the estimated angle and is further processed as if it were a frontal view image. The encoding technique developed for a frontal image is based on the application of the global independent component analysis. The second approach uses an angular deformation calibration model. The angular deformations are modeled, and calibration parameters are calculated. The proposed method consists of a closed-form solution, followed by an iterative optimization procedure. The images are projected on the plane closest to the base calibrated plane. Biorthogonal wavelets are used for encoding to perform iris recognition. We use a special dataset of the off-angle iris images to quantify the performance of the designed systems. A series of receiver operating characteristics demonstrate various effects on the performance of the nonideal-iris-based recognition system.

  4. A Serviced-based Approach to Connect Seismological Infrastructures: Current Efforts at the IRIS DMC

    NASA Astrophysics Data System (ADS)

    Ahern, Tim; Trabant, Chad

    2014-05-01

    As part of the COOPEUS initiative to build infrastructure that connects European and US research infrastructures, IRIS has advocated for the development of Federated services based upon internationally recognized standards using web services. By deploying International Federation of Digital Seismograph Networks (FDSN) endorsed web services at multiple data centers in the US and Europe, we have shown that integration within seismological domain can be realized. By deploying identical methods to invoke the web services at multiple centers this approach can significantly ease the methods through which a scientist can access seismic data (time series, metadata, and earthquake catalogs) from distributed federated centers. IRIS has developed an IRIS federator that helps a user identify where seismic data from global seismic networks can be accessed. The web services based federator can build the appropriate URLs and return them to client software running on the scientists own computer. These URLs are then used to directly pull data from the distributed center in a very peer-based fashion. IRIS is also involved in deploying web services across horizontal domains. As part of the US National Science Foundation's (NSF) EarthCube effort, an IRIS led EarthCube Building Block's project is underway. When completed this project will aid in the discovery, access, and usability of data across multiple geoscienece domains. This presentation will summarize current IRIS efforts in building vertical integration infrastructure within seismology working closely with 5 centers in Europe and 2 centers in the US, as well as how we are taking first steps toward horizontal integration of data from 14 different domains in the US, in Europe, and around the world.

  5. Iris indexing based on local intensity order pattern

    NASA Astrophysics Data System (ADS)

    Emerich, Simina; Malutan, Raul; Crisan, Septimiu; Lefkovits, Laszlo

    2017-03-01

    In recent years, iris biometric systems have increased in popularity and have been proven that are capable of handling large-scale databases. The main advantage of these systems is accuracy and reliability. A proper iris patterns classification is expected to reduce the matching time in huge databases. This paper presents an iris indexing technique based on Local Intensity Order Pattern. The performance of the present approach is evaluated on UPOL database and is compared with other recent systems designed for iris indexing. The results illustrate the potential of the proposed method for large scale iris identification.

  6. Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition

    PubMed Central

    Islam, Md. Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al. PMID:25114676

  7. Feature and score fusion based multiple classifier selection for iris recognition.

    PubMed

    Islam, Md Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  8. Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera

    PubMed Central

    Chen, Hao; Woodward, Maria A.; Burke, David T.; Jeganathan, V. Swetha E.; Demirci, Hakan; Sick, Volker

    2017-01-01

    A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring. PMID:29082081

  9. Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera.

    PubMed

    Chen, Hao; Woodward, Maria A; Burke, David T; Jeganathan, V Swetha E; Demirci, Hakan; Sick, Volker

    2017-10-01

    A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring.

  10. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    EPA Pesticide Factsheets

    EPA is developing an Integrated Risk Information System (IRIS) assessment of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and has released the draft assessment for public comment. When final, the assessment will appear on the IRIS database. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  11. 78 FR 18426 - Proposed Information Collection (IRIS) Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Proposed Information Collection (IRIS... through the Inquiry Routing and Information System (IRIS). DATES: Written comments and recommendations on... information technology. Title: Inquiry Routing and Information System (IRIS), VA Form 0873. OMB Control Number...

  12. Novel Approaches to Improve Iris Recognition System Performance Based on Local Quality Evaluation and Feature Fusion

    PubMed Central

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system. PMID:24693243

  13. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    PubMed

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  14. The fast iris image clarity evaluation based on Tenengrad and ROI selection

    NASA Astrophysics Data System (ADS)

    Gao, Shuqin; Han, Min; Cheng, Xu

    2018-04-01

    In iris recognition system, the clarity of iris image is an important factor that influences recognition effect. In the process of recognition, the blurred image may possibly be rejected by the automatic iris recognition system, which will lead to the failure of identification. Therefore it is necessary to evaluate the iris image definition before recognition. Considered the existing evaluation methods on iris image definition, we proposed a fast algorithm to evaluate the definition of iris image in this paper. In our algorithm, firstly ROI (Region of Interest) is extracted based on the reference point which is determined by using the feature of the light spots within the pupil, then Tenengrad operator is used to evaluate the iris image's definition. Experiment results show that, the iris image definition algorithm proposed in this paper could accurately distinguish the iris images of different clarity, and the algorithm has the merit of low computational complexity and more effectiveness.

  15. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (Interagency Science Consultation Draft)

    EPA Science Inventory

    On March 10, 2016, the public comment draft Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine and the draft charge to external peer reviewers were released for public review and comment. The Toxicological Review and charge were reviewed internally by EPA and by othe...

  16. 75 FR 60454 - Draft Toxicological Review of Hexavalent Chromium: In Support of Summary Information on the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-30

    ... present scientific and technical comments on draft IRIS health assessments to EPA and other interested... to share their comments with the external peer reviewers, they should also submit written comments..., and ends November 29, 2010. Comments should be in writing and must be received by EPA by November 29...

  17. 76 FR 53125 - Draft Toxicological Review of Libby Amphibole Asbestos: In Support of the Summary Information on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-25

    ... is to allow all interested parties to present scientific and technical comments on draft IRIS health... and technical comments that will be provided to the Agency by the listening session participants. The... peer reviewers, they should also submit written comments during the public comment period using the...

  18. 75 FR 8937 - Development of a Relative Potency Factor (RPF) Approach for Polycyclic Aromatic Hydrocarbon (PAH...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... public comment period and the EPA Science Advisory Board (SAB) peer review meeting, which will be... listening session is a step in EPA's revised IRIS process, announced on May 21, 2009, for developing human... audio-visual aid (e.g., laptop computer and slide projector). In general, each presentation should be no...

  19. Iris Location Algorithm Based on the CANNY Operator and Gradient Hough Transform

    NASA Astrophysics Data System (ADS)

    Zhong, L. H.; Meng, K.; Wang, Y.; Dai, Z. Q.; Li, S.

    2017-12-01

    In the iris recognition system, the accuracy of the localization of the inner and outer edges of the iris directly affects the performance of the recognition system, so iris localization has important research meaning. Our iris data contain eyelid, eyelashes, light spot and other noise, even the gray transformation of the images is not obvious, so the general methods of iris location are unable to realize the iris location. The method of the iris location based on Canny operator and gradient Hough transform is proposed. Firstly, the images are pre-processed; then, calculating the gradient information of images, the inner and outer edges of iris are coarse positioned using Canny operator; finally, according to the gradient Hough transform to realize precise localization of the inner and outer edge of iris. The experimental results show that our algorithm can achieve the localization of the inner and outer edges of the iris well, and the algorithm has strong anti-interference ability, can greatly reduce the location time and has higher accuracy and stability.

  20. A new method for generating an invariant iris private key based on the fuzzy vault system.

    PubMed

    Lee, Youn Joo; Park, Kang Ryoung; Lee, Sung Joo; Bae, Kwanghyuk; Kim, Jaihie

    2008-10-01

    Cryptographic systems have been widely used in many information security applications. One main challenge that these systems have faced has been how to protect private keys from attackers. Recently, biometric cryptosystems have been introduced as a reliable way of concealing private keys by using biometric data. A fuzzy vault refers to a biometric cryptosystem that can be used to effectively protect private keys and to release them only when legitimate users enter their biometric data. In biometric systems, a critical problem is storing biometric templates in a database. However, fuzzy vault systems do not need to directly store these templates since they are combined with private keys by using cryptography. Previous fuzzy vault systems were designed by using fingerprint, face, and so on. However, there has been no attempt to implement a fuzzy vault system that used an iris. In biometric applications, it is widely known that an iris can discriminate between persons better than other biometric modalities. In this paper, we propose a reliable fuzzy vault system based on local iris features. We extracted multiple iris features from multiple local regions in a given iris image, and the exact values of the unordered set were then produced using the clustering method. To align the iris templates with the new input iris data, a shift-matching technique was applied. Experimental results showed that 128-bit private keys were securely and robustly generated by using any given iris data without requiring prealignment.

  1. 78 FR 23233 - Agency Information Collection Activities; Comment Request; IEPS International Resource...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-18

    ...; Comment Request; IEPS International Resource Information System (IRIS) AGENCY: Office of Postsecondary... System (IRIS). OMB Control Number: 1840-0759. Type of Review: a revision of an existing information... reporting system, International Resource Information System (IRIS) that IFLE uses to collect annual...

  2. Iris recognition in the presence of ocular disease

    PubMed Central

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-01-01

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology. PMID:19324690

  3. Iris recognition in the presence of ocular disease.

    PubMed

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-05-06

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology.

  4. A bibliography of IRIS-related publications, 2000-2011

    NASA Astrophysics Data System (ADS)

    Muco, B.

    2012-12-01

    Citations and acknowledgements in scientific journals can be an indicator of the role an organization has on the research of that field. Since its formation and incorporation in May 1984, the IRIS Consortium (Incorporated Research Institutions for Seismology) is mentioned more and more as a valuable source of data, instruments and programs in the literature of earth sciences. As a large organization with more than 100 member domestic institutes and about 40 international affiliates, obviously IRIS has a direct impact on the earth sciences through all its programs, projects, workshops, symposia, and news¬letters and as a lively forum for exchanging ideas. In order to maintain support from National Science Foundation (NSF) and the research community, it is important to document the continued use of IRIS facilities in basic research programs. IRIS maintains a database of articles that are based on the use of IRIS facilities or which reference use of IRIS data and resources. Articles in this database have been either been provided to IRIS by the authors or selected through an annual search of a number of prominent journals. A text version of the full bibliographic database is available on the IRIS website and a version in EndNote format is also provided. To provide a more complete bibliography and a consistent evaluation of temporal tends in publications, a special annual search began in 2000 which focused on a subset of key seismology and Earth science journals: Bulletin of Seismological Society of America, Journal of Geophysical Research, Seismological Research Letters, Geophysical Research Letters, Earth and Planetary Science Letters, Physics of the Earth and Planetary Interiors, Tectonophysics, Geophysical Journal International, Nature, Science, Geology and EOS. Using different search engines as Scirus, ScienceDirect, GeoRef, OCLC First Search, EASI Search, NASA Abstract Service etc. for online journals and publishers' databases, we searched for key words (IRIS, GSN, DMS, PASSCAL, USArray etc) in titles, abstracts and text. Most of the selections found by this method were confirmed by reading through online texts or original journals. This bibliography of peer-reviewed articles (excluding abstracts) identified in these key journals for 2000-2011 includes approximately 1800 entries. As for American Geophysical Union (AGU) transaction, the bibliography of IRIS-related abstracts for the abovementioned period includes approximately 1400 abstracts. This study is a clear indicator of making intensive use by the seismological community of the resources that IRIS provides and of the paramount importance this organization has in advancement of seismological research worldwide.

  5. Toward More Accurate Iris Recognition Using Cross-Spectral Matching.

    PubMed

    Nalla, Pattabhi Ramaiah; Kumar, Ajay

    2017-01-01

    Iris recognition systems are increasingly deployed for large-scale applications such as national ID programs, which continue to acquire millions of iris images to establish identity among billions. However, with the availability of variety of iris sensors that are deployed for the iris imaging under different illumination/environment, significant performance degradation is expected while matching such iris images acquired under two different domains (either sensor-specific or wavelength-specific). This paper develops a domain adaptation framework to address this problem and introduces a new algorithm using Markov random fields model to significantly improve cross-domain iris recognition. The proposed domain adaptation framework based on the naive Bayes nearest neighbor classification uses a real-valued feature representation, which is capable of learning domain knowledge. Our approach to estimate corresponding visible iris patterns from the synthesis of iris patches in the near infrared iris images achieves outperforming results for the cross-spectral iris recognition. In this paper, a new class of bi-spectral iris recognition system that can simultaneously acquire visible and near infra-red images with pixel-to-pixel correspondences is proposed and evaluated. This paper presents experimental results from three publicly available databases; PolyU cross-spectral iris image database, IIITD CLI and UND database, and achieve outperforming results for the cross-sensor and cross-spectral iris matching.

  6. Iris unwrapping using the Bresenham circle algorithm for real-time iris recognition

    NASA Astrophysics Data System (ADS)

    Carothers, Matthew T.; Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.

    2015-02-01

    An efficient parallel architecture design for the iris unwrapping process in a real-time iris recognition system using the Bresenham Circle Algorithm is presented in this paper. Based on the characteristics of the model parameters this algorithm was chosen over the widely used polar conversion technique as the iris unwrapping model. The architecture design is parallelized to increase the throughput of the system and is suitable for processing an inputted image size of 320 × 240 pixels in real-time using Field Programmable Gate Array (FPGA) technology. Quartus software is used to implement, verify, and analyze the design's performance using the VHSIC Hardware Description Language. The system's predicted processing time is faster than the modern iris unwrapping technique used today∗.

  7. 76 FR 60827 - Draft Toxicological Review of Biphenyl: In Support of Summary Information on the Integrated Risk...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... to present scientific and technical comments on draft IRIS health assessments to EPA and other... would like EPA to share their comments with the external peer reviewers, they should also submit written..., and ends November 29, 2011. Comments should be in writing and must be received by EPA by November 29...

  8. Meeting Materials for the 4th NRC Meeting on the Guidance for and the Review of EPA's Toxicological Assessment of Inorganic Arsenic

    EPA Science Inventory

    On December 2-3, 2015, the National Research Council (NRC) hosted the 4th meeting of the committee formed to peer review the draft IRIS assessment of inorganic arsenic. EPA presented background and overview materials during the public session on December 2nd. This information co...

  9. Computational cameras for moving iris recognition

    NASA Astrophysics Data System (ADS)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  10. The IRIS-GUS Shuttle Borne Upper Stage System

    NASA Technical Reports Server (NTRS)

    Tooley, Craig; Houghton, Martin; Bussolino, Luigi; Connors, Paul; Broudeur, Steve (Technical Monitor)

    2002-01-01

    This paper describes the Italian Research Interim Stage - Gyroscopic Upper Stage (IRIS-GUS) upper stage system that will be used to launch NASA's Triana Observatory from the Space Shuttle. Triana is a pathfinder earth science mission being executed on rapid schedule and small budget, therefore the mission's upper stage solution had to be a system that could be fielded quickly at relatively low cost and risk. The building of the IRIS-GUS system wa necessary because NASA lost the capability to launch moderately sized upper stage missions fro the Space Shuttle when the PAM-D system was retired. The IRIS-GUS system restores this capability. The resulting system is a hybrid which mates the existing, flight proven IRIS (Italian Research Interim Stage) airborne support equipment to a new upper stage, the Gyroscopic Upper Stage (GUS) built by the GSFC for Triana. Although a new system, the GUS exploits flight proven hardware and design approaches in most subsystems, in some cases implementing proven design approaches with state-of-the-art electronics. This paper describes the IRIS-GUS upper stage system elements, performance capabilities, and payload interfaces.

  11. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    NASA Astrophysics Data System (ADS)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  12. Multiple local feature representations and their fusion based on an SVR model for iris recognition using optimized Gabor filters

    NASA Astrophysics Data System (ADS)

    He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Dong, Hongxing

    2014-12-01

    Gabor descriptors have been widely used in iris texture representations. However, fixed basic Gabor functions cannot match the changing nature of diverse iris datasets. Furthermore, a single form of iris feature cannot overcome difficulties in iris recognition, such as illumination variations, environmental conditions, and device variations. This paper provides multiple local feature representations and their fusion scheme based on a support vector regression (SVR) model for iris recognition using optimized Gabor filters. In our iris system, a particle swarm optimization (PSO)- and a Boolean particle swarm optimization (BPSO)-based algorithm is proposed to provide suitable Gabor filters for each involved test dataset without predefinition or manual modulation. Several comparative experiments on JLUBR-IRIS, CASIA-I, and CASIA-V4-Interval iris datasets are conducted, and the results show that our work can generate improved local Gabor features by using optimized Gabor filters for each dataset. In addition, our SVR fusion strategy may make full use of their discriminative ability to improve accuracy and reliability. Other comparative experiments show that our approach may outperform other popular iris systems.

  13. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    PubMed Central

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  14. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    PubMed

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  15. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing

    DOT National Transportation Integrated Search

    2011-12-31

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  16. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing.

    DOT National Transportation Integrated Search

    2011-12-01

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  17. Noisy Ocular Recognition Based on Three Convolutional Neural Networks.

    PubMed

    Lee, Min Beom; Hong, Hyung Gil; Park, Kang Ryoung

    2017-12-17

    In recent years, the iris recognition system has been gaining increasing acceptance for applications such as access control and smartphone security. When the images of the iris are obtained under unconstrained conditions, an issue of undermined quality is caused by optical and motion blur, off-angle view (the user's eyes looking somewhere else, not into the front of the camera), specular reflection (SR) and other factors. Such noisy iris images increase intra-individual variations and, as a result, reduce the accuracy of iris recognition. A typical iris recognition system requires a near-infrared (NIR) illuminator along with an NIR camera, which are larger and more expensive than fingerprint recognition equipment. Hence, many studies have proposed methods of using iris images captured by a visible light camera without the need for an additional illuminator. In this research, we propose a new recognition method for noisy iris and ocular images by using one iris and two periocular regions, based on three convolutional neural networks (CNNs). Experiments were conducted by using the noisy iris challenge evaluation-part II (NICE.II) training dataset (selected from the university of Beira iris (UBIRIS).v2 database), mobile iris challenge evaluation (MICHE) database, and institute of automation of Chinese academy of sciences (CASIA)-Iris-Distance database. As a result, the method proposed by this study outperformed previous methods.

  18. Iris recognition and what is next? Iris diagnosis: a new challenging topic for machine vision from image acquisition to image interpretation

    NASA Astrophysics Data System (ADS)

    Perner, Petra

    2017-03-01

    Molecular image-based techniques are widely used in medicine to detect specific diseases. Look diagnosis is an important issue but also the analysis of the eye plays an important role in order to detect specific diseases. These topics are important topics in medicine and the standardization of these topics by an automatic system can be a new challenging field for machine vision. Compared to iris recognition has the iris diagnosis much more higher demands for the image acquisition and interpretation of the iris. One understands by iris diagnosis (Iridology) the investigation and analysis of the colored part of the eye, the iris, to discover factors, which play an important role for the prevention and treatment of illnesses, but also for the preservation of an optimum health. An automatic system would pave the way for a much wider use of the iris diagnosis for the diagnosis of illnesses and for the purpose of individual health protection. With this paper, we describe our work towards an automatic iris diagnosis system. We describe the image acquisition and the problems with it. Different ways are explained for image acquisition and image preprocessing. We describe the image analysis method for the detection of the iris. The meta-model for image interpretation is given. Based on this model we show the many tasks for image analysis that range from different image-object feature analysis, spatial image analysis to color image analysis. Our first results for the recognition of the iris are given. We describe how detecting the pupil and not wanted lamp spots. We explain how to recognize orange blue spots in the iris and match them against the topological map of the iris. Finally, we give an outlook for further work.

  19. [Moxiflaxin and iris transillumination].

    PubMed

    Broens, A; Collignon, N

    2016-07-01

    Bilateral Acute Iris Transillumination (BAIT) is a new clinical entity characterized by acute onset of pigment dispersion in the anterior chamber and angle, depigmentation of the iris stroma and permanent iris transillumination, masquerading as uveitis. An association with oral moxifloxacin is reported in some articles. We describe one case of bilateral acute iris transillumination, following the use of systemic moxifloxacin.

  20. A hyperspectral imaging system for the evaluation of the human iris spectral reflectance

    NASA Astrophysics Data System (ADS)

    Di Cecilia, Luca; Marazzi, Francesco; Rovati, Luigi

    2017-02-01

    According to previous studies, the measurement of the human iris pigmentation can be exploited to detect certain eye pathological conditions in their early stage. In this paper, we propose an instrument and a method to perform hyperspectral quantitative measurements of the iris spectral reflectance. The system is based on a simple imaging setup, which includes a monochrome camera mounted on a standard ophthalmic microscope movement controller, a monochromator, and a flashing LED-based slit lamp. To assure quantitative measurements, the system is properly calibrated against a NIST reflectance standard. Iris reflectance images can be obtained in the spectral range 495-795 nm with a resolution of 25 nm. Each image consists of 1280 x 1024 pixels having a spatial resolution of 18 μm. Reflectance spectra can be calculated both from discrete areas of the iris and as the average of the whole iris surface. Preliminary results suggest that hyperspectral imaging of the iris can provide much more morphological and spectral information with respect to conventional qualitative colorimetric methods.

  1. Analysis of Four Automated Urinalysis Systems Compared to Reference Methods.

    PubMed

    Bartosova, Kamila; Kubicek, Zdenek; Franekova, Janka; Louzensky, Gustav; Lavrikova, Petra; Jabor, Antonin

    2016-11-01

    The aim of this study was to compare four automated urinalysis systems: the Iris iQ200 Sprint (Iris Diagnostics, U.S.A.) combined with the Arkray AUTION MAX AX 4030, Iris + AUTION, Arkray AU 4050 (Arkray Global Business, Inc., Japan), Dirui FUS 2000 (Dirui Industrial Co., P.R.C.), and Menarini sediMAX (Menarini, Italy). Urine concentrations of protein and glucose (Iris, Dirui) were compared using reference quantitative analysis on an Abbott Architect c16000. Leukocytes, erythrocytes, epithelia, and casts (Iris, Arkray, Diuri, Menarini) were compared to urine sediment under reference light microscopy, Leica DM2000 (Leica Microsystems GmbH, Germany) with calibrated FastRead plates (Biosigma S.r.l., Italy), using both native and stained preparations. Total protein and glucose levels were measured using the Iris + AUTION system with borderline trueness, while the Dirui analysis revealed worse performances for the protein and glucose measurements. True classifications of leukocytes and erythrocytes were above 85% and 72%, respectively. Kappa statistics revealed a nearly perfect evaluation of leukocytes for all tested systems; the erythrocyte evaluation was nearly perfect for the Iris, Dirui and Arkray analyzers and substantial for the Menarini analyzer. The epithelia identification was connected to high false negativity (above 15%) in the Iris, Arkray, and Menarini analyses. False-negative casts were above 70% for all tested systems. The use of automated urinalysis demonstrated some weaknesses and should be checked by experienced laboratory staff using light microscopy.

  2. Vascular tumors of the iris in 45 patients: the 2009 Helen Keller Lecture.

    PubMed

    Shields, Jerry A; Bianciotto, Carlos; Kligman, Brad E; Shields, Carol L

    2010-09-01

    To report on a series of vascular tumors of the iris. Noncomparative case series. A retrospective medical record review of all patients with an iris vascular tumor was performed to identify the clinical features and develop a simple classification of these lesions. Included were demographics, clinical features, systemic associations, complications, management, and histopathology. There were 54 eyes in 45 patients with an iris vascular tumor. These were categorized as racemose hemangioma (41 eyes: 29 simple and 12 complex), cavernous hemangioma (3 eyes: 2 localized and 1 systemic), capillary hemangioma (1 eye, localized), varix (3 eyes, localized), and microhemangiomatosis (6 eyes, localized). The hemangiomas occurred in adults at a median age of 55 years, whereas capillary hemangioma occurred in infancy and cavernous hemangioma with systemic involvement occurred in a child. Of the 41 eyes with iris racemose hemangioma, none showed systemic involvement. Of all 54 eyes, transient hyphema was the main complication, found at some point in 30% or more of each affected eye except for iris capillary and racemose hemangioma. Surgical resection was necessary in 1 cavernous hemangioma and 1 varix. The remainder were managed with observation. There are now well-documented examples of iris racemose hemangioma, cavernous hemangioma, capillary hemangioma, varix, and microhemangiomatosis. Transient hyphema is the main complication. Observation is usually advised. Most are solitary lesions confined to the iris and some (cavernous hemangioma and microhemangiomatosis) can have important systemic associations.

  3. 78 FR 49486 - Agency Information Collection Activities; Submission to the Office of Management and Budget for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... International Resource Information System (IRIS) AGENCY: Office of Postsecondary Education (OPE), Department of... Resource Information System (IRIS). OMB Control Number: 1840-0759. Type of Review: Revision of an existing... Information System (IRIS) that IFLE uses to collect annual performance reports from Title VI and Fulbright...

  4. Iris Recognition: The Consequences of Image Compression

    NASA Astrophysics Data System (ADS)

    Ives, Robert W.; Bishop, Daniel A.; Du, Yingzi; Belcher, Craig

    2010-12-01

    Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA) is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  5. Noisy Ocular Recognition Based on Three Convolutional Neural Networks

    PubMed Central

    Lee, Min Beom; Hong, Hyung Gil; Park, Kang Ryoung

    2017-01-01

    In recent years, the iris recognition system has been gaining increasing acceptance for applications such as access control and smartphone security. When the images of the iris are obtained under unconstrained conditions, an issue of undermined quality is caused by optical and motion blur, off-angle view (the user’s eyes looking somewhere else, not into the front of the camera), specular reflection (SR) and other factors. Such noisy iris images increase intra-individual variations and, as a result, reduce the accuracy of iris recognition. A typical iris recognition system requires a near-infrared (NIR) illuminator along with an NIR camera, which are larger and more expensive than fingerprint recognition equipment. Hence, many studies have proposed methods of using iris images captured by a visible light camera without the need for an additional illuminator. In this research, we propose a new recognition method for noisy iris and ocular images by using one iris and two periocular regions, based on three convolutional neural networks (CNNs). Experiments were conducted by using the noisy iris challenge evaluation-part II (NICE.II) training dataset (selected from the university of Beira iris (UBIRIS).v2 database), mobile iris challenge evaluation (MICHE) database, and institute of automation of Chinese academy of sciences (CASIA)-Iris-Distance database. As a result, the method proposed by this study outperformed previous methods. PMID:29258217

  6. Multi-Patches IRIS Based Person Authentication System Using Particle Swarm Optimization and Fuzzy C-Means Clustering

    NASA Astrophysics Data System (ADS)

    Shekar, B. H.; Bhat, S. S.

    2017-05-01

    Locating the boundary parameters of pupil and iris and segmenting the noise free iris portion are the most challenging phases of an automated iris recognition system. In this paper, we have presented person authentication frame work which uses particle swarm optimization (PSO) to locate iris region and circular hough transform (CHT) to device the boundary parameters. To undermine the effect of the noise presented in the segmented iris region we have divided the candidate region into N patches and used Fuzzy c-means clustering (FCM) to classify the patches into best iris region and not so best iris region (noisy region) based on the probability density function of each patch. Weighted mean Hammimng distance is adopted to find the dissimilarity score between the two candidate irises. We have used Log-Gabor, Riesz and Taylor's series expansion (TSE) filters and combinations of these three for iris feature extraction. To justify the feasibility of the proposed method, we experimented on the three publicly available data sets IITD, MMU v-2 and CASIA v-4 distance.

  7. The infrared imaging spectrograph (IRIS) for TMT: latest science cases and simulations

    NASA Astrophysics Data System (ADS)

    Wright, Shelley A.; Walth, Gregory; Do, Tuan; Marshall, Daniel; Larkin, James E.; Moore, Anna M.; Adamkovics, Mate; Andersen, David; Armus, Lee; Barth, Aaron; Cote, Patrick; Cooke, Jeff; Chisholm, Eric M.; Davidge, Timothy; Dunn, Jennifer S.; Dumas, Christophe; Ellerbroek, Brent L.; Ghez, Andrea M.; Hao, Lei; Hayano, Yutaka; Liu, Michael; Lopez-Rodriguez, Enrique; Lu, Jessica R.; Mao, Shude; Marois, Christian; Pandey, Shashi B.; Phillips, Andrew C.; Schoeck, Matthias; Subramaniam, Annapurni; Subramanian, Smitha; Suzuki, Ryuji; Tan, Jonathan C.; Terai, Tsuyoshi; Treu, Tommaso; Simard, Luc; Weiss, Jason L.; Wincentsen, James; Wong, Michael; Zhang, Kai

    2016-07-01

    The Thirty Meter Telescope (TMT) first light instrument IRIS (Infrared Imaging Spectrograph) will complete its preliminary design phase in 2016. The IRIS instrument design includes a near-infrared (0.85 - 2.4 micron) integral field spectrograph (IFS) and imager that are able to conduct simultaneous diffraction-limited observations behind the advanced adaptive optics system NFIRAOS. The IRIS science cases have continued to be developed and new science studies have been investigated to aid in technical performance and design requirements. In this development phase, the IRIS science team has paid particular attention to the selection of filters, gratings, sensitivities of the entire system, and science cases that will benefit from the parallel mode of the IFS and imaging camera. We present new science cases for IRIS using the latest end-to-end data simulator on the following topics: Solar System bodies, the Galactic center, active galactic nuclei (AGN), and distant gravitationally-lensed galaxies. We then briefly discuss the necessity of an advanced data management system and data reduction pipeline.

  8. A novel iris patterns matching algorithm of weighted polar frequency correlation

    NASA Astrophysics Data System (ADS)

    Zhao, Weijie; Jiang, Linhua

    2014-11-01

    Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.

  9. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (Public Comment Draft)

    EPA Science Inventory

    In September 2016, the U.S. Environmental Protection Agency's (USEPA) released the draft Integrated Risk Information System (IRIS) Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE). Consistent with the 2013 IRIS Enhancements, draft IRIS assessments are released prior to e...

  10. Extending the Capture Volume of an Iris Recognition System Using Wavefront Coding and Super-Resolution.

    PubMed

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao; Chang, Chin-Chen

    2016-12-01

    Iris recognition has gained increasing popularity over the last few decades; however, the stand-off distance in a conventional iris recognition system is too short, which limits its application. In this paper, we propose a novel hardware-software hybrid method to increase the stand-off distance in an iris recognition system. When designing the system hardware, we use an optimized wavefront coding technique to extend the depth of field. To compensate for the blurring of the image caused by wavefront coding, on the software side, the proposed system uses a local patch-based super-resolution method to restore the blurred image to its clear version. The collaborative effect of the new hardware design and software post-processing showed great potential in our experiment. The experimental results showed that such improvement cannot be achieved by using a hardware-or software-only design. The proposed system can increase the capture volume of a conventional iris recognition system by three times and maintain the system's high recognition rate.

  11. Trade off between variable and fixed size normalization in orthogonal polynomials based iris recognition system.

    PubMed

    Krishnamoorthi, R; Anna Poorani, G

    2016-01-01

    Iris normalization is an important stage in any iris biometric, as it has a propensity to trim down the consequences of iris distortion. To indemnify the variation in size of the iris owing to the action of stretching or enlarging the pupil in iris acquisition process and camera to eyeball distance, two normalization schemes has been proposed in this work. In the first method, the iris region of interest is normalized by converting the iris into the variable size rectangular model in order to avoid the under samples near the limbus border. In the second method, the iris region of interest is normalized by converting the iris region into a fixed size rectangular model in order to avoid the dimensional discrepancies between the eye images. The performance of the proposed normalization methods is evaluated with orthogonal polynomials based iris recognition in terms of FAR, FRR, GAR, CRR and EER.

  12. 75 FR 28856 - Agency Information Collection (IRIS) Activities Under OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-24

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Agency Information Collection (IRIS... Information System (IRIS). OMB Control Number: 2900-0619. Type of Review: Extension of a currently approved... veterans, dependents, and active duty personnel worldwide. IRIS allows a customer to submit questions...

  13. 75 FR 13208 - Proposed Information Collection (IRIS) Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Proposed Information Collection (IRIS... submitted to VA through the Inquiry Routing and Information System (IRIS). DATES: Written comments and... (IRIS), VA Form 0873. OMB Control Number: 2900-0619. Type of Review: Extension of a currently approved...

  14. Reducing Error Rates for Iris Image using higher Contrast in Normalization process

    NASA Astrophysics Data System (ADS)

    Aminu Ghali, Abdulrahman; Jamel, Sapiee; Abubakar Pindar, Zahraddeen; Hasssan Disina, Abdulkadir; Mat Daris, Mustafa

    2017-08-01

    Iris recognition system is the most secured, and faster means of identification and authentication. However, iris recognition system suffers a setback from blurring, low contrast and illumination due to low quality image which compromises the accuracy of the system. The acceptance or rejection rates of verified user depend solely on the quality of the image. In many cases, iris recognition system with low image contrast could falsely accept or reject user. Therefore this paper adopts Histogram Equalization Technique to address the problem of False Rejection Rate (FRR) and False Acceptance Rate (FAR) by enhancing the contrast of the iris image. A histogram equalization technique enhances the image quality and neutralizes the low contrast of the image at normalization stage. The experimental result shows that Histogram Equalization Technique has reduced FRR and FAR compared to the existing techniques.

  15. IRIS Toxicological Review of Benzo[a]pyrene (Final Report) ...

    EPA Pesticide Factsheets

    EPA has finalized the Integrated Risk Information System (IRIS) assessment of benzo[a]pyrene. This assessment addresses the potential cancer and noncancer human health effects from long-term exposure to benzo[a]pyrene. Now final, this assessment will update the toxicological information on benzo[a]pyrene posted in 1987. EPA’s program and regional offices may use this assessment to inform decisions to protect human health. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  16. A new phase-correlation-based iris matching for degraded images.

    PubMed

    Krichen, Emine; Garcia-Salicetti, Sonia; Dorizzi, Bernadette

    2009-08-01

    In this paper, we present a new phase-correlation-based iris matching approach in order to deal with degradations in iris images due to unconstrained acquisition procedures. Our matching system is a fusion of global and local Gabor phase-correlation schemes. The main originality of our local approach is that we do not only consider the correlation peak amplitudes but also their locations in different regions of the images. Results on several degraded databases, namely, the CASIA-BIOSECURE and Iris Challenge Evaluation 2005 databases, show the improvement of our method compared to two available reference systems, Masek and Open Source for Iris (OSRIS), in verification mode.

  17. Multispectral iris recognition based on group selection and game theory

    NASA Astrophysics Data System (ADS)

    Ahmad, Foysal; Roy, Kaushik

    2017-05-01

    A commercially available iris recognition system uses only a narrow band of the near infrared spectrum (700-900 nm) while iris images captured in the wide range of 405 nm to 1550 nm offer potential benefits to enhance recognition performance of an iris biometric system. The novelty of this research is that a group selection algorithm based on coalition game theory is explored to select the best patch subsets. In this algorithm, patches are divided into several groups based on their maximum contribution in different groups. Shapley values are used to evaluate the contribution of patches in different groups. Results show that this group selection based iris recognition

  18. Limbus Impact on Off-angle Iris Degradation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J

    The accuracy of iris recognition depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. Off-angle iris recognition is a new research focus in biometrics that tries to address several issues including corneal refraction, complex 3D iris texture, and blur. In this paper, we present an additional significant challenge that degrades the performance of the off-angle iris recognition systems, called the limbus effect . The limbus is the region at the border of the cornea where the cornea joins the sclera. The limbus is a semitransparent tissue that occludes amore » side portion of the iris plane. The amount of occluded iris texture on the side nearest the camera increases as the image acquisition angle increases. Without considering the role of the limbus effect, it is difficult to design an accurate off-angle iris recognition system. To the best of our knowledge, this is the first work that investigates the limbus effect in detail from a biometrics perspective. Based on results from real images and simulated experiments with real iris texture, the limbus effect increases the hamming distance score between frontal and off-angle iris images ranging from 0.05 to 0.2 depending upon the limbus height.« less

  19. Iris recognition as a biometric method after cataract surgery

    PubMed Central

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-01

    Background Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Methods Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. Results A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Conclusions Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure. PMID:14748929

  20. Iris recognition as a biometric method after cataract surgery.

    PubMed

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  1. Iris biometric system design using multispectral imaging

    NASA Astrophysics Data System (ADS)

    Widhianto, Benedictus Yohanes Bagus Y. B.; Nasution, Aulia M. T.

    2016-11-01

    An identity recognition system is a vital component that cannot be separated from life, iris biometric is one of the biometric that has the best accuracy reaching 99%. Usually, iris biometric systems use infrared spectrum lighting to reduce discomfort caused by radiation when the eye is given direct light, while the eumelamin that is forming the iris has the most flourescent radiation when given a spectrum of visible light. This research will be conducted by detecting iris wavelengths of 850 nm, 560 nm, and 590 nm, where the detection algorithm will be using Daugman algorithm by using a Gabor wavelet extraction feature, and matching feature using a Hamming distance. Results generated will be analyzed to identify how much differences there are, and to improve the accuracy of the multispectral biometric system and as a detector of the authenticity of the iris. The results obtained from the analysis of wavelengths 850 nm, 560 nm, and 590 nm respectively has an accuracy of 99,35 , 97,5 , 64,5 with a matching score of 0,26 , 0,23 , 0,37.

  2. Iris recognition using possibilistic fuzzy matching on local features.

    PubMed

    Tsai, Chung-Chih; Lin, Heng-Yi; Taur, Jinshiuh; Tao, Chin-Wang

    2012-02-01

    In this paper, we propose a novel possibilistic fuzzy matching strategy with invariant properties, which can provide a robust and effective matching scheme for two sets of iris feature points. In addition, the nonlinear normalization model is adopted to provide more accurate position before matching. Moreover, an effective iris segmentation method is proposed to refine the detected inner and outer boundaries to smooth curves. For feature extraction, the Gabor filters are adopted to detect the local feature points from the segmented iris image in the Cartesian coordinate system and to generate a rotation-invariant descriptor for each detected point. After that, the proposed matching algorithm is used to compute a similarity score for two sets of feature points from a pair of iris images. The experimental results show that the performance of our system is better than those of the systems based on the local features and is comparable to those of the typical systems.

  3. Forging a link between mentoring and collaboration: a new training model for implementation science.

    PubMed

    Luke, Douglas A; Baumann, Ana A; Carothers, Bobbi J; Landsverk, John; Proctor, Enola K

    2016-10-13

    Training investigators for the rapidly developing field of implementation science requires both mentoring and scientific collaboration. Using social network descriptive analyses, visualization, and modeling, this paper presents results of an evaluation of the mentoring and collaborations fostered over time through the National Institute of Mental Health (NIMH) supported by Implementation Research Institute (IRI). Data were comprised of IRI participant self-reported collaborations and mentoring relationships, measured in three annual surveys from 2012 to 2014. Network descriptive statistics, visualizations, and network statistical modeling were conducted to examine patterns of mentoring and collaboration among IRI participants and to model the relationship between mentoring and subsequent collaboration. Findings suggest that IRI is successful in forming mentoring relationships among its participants, and that these mentoring relationships are related to future scientific collaborations. Exponential random graph network models demonstrated that mentoring received in 2012 was positively and significantly related to the likelihood of having a scientific collaboration 2 years later in 2014 (p = 0.001). More specifically, mentoring was significantly related to future collaborations focusing on new research (p = 0.009), grant submissions (p = 0.003), and publications (p = 0.017). Predictions based on the network model suggest that for every additional mentoring relationships established in 2012, the likelihood of a scientific collaboration 2 years later is increased by almost 7 %. These results support the importance of mentoring in implementation science specifically and team science more generally. Mentoring relationships were established quickly and early by the IRI core faculty. IRI fellows reported increasing scientific collaboration of all types over time, including starting new research, submitting new grants, presenting research results, and publishing peer-reviewed papers. Statistical network models demonstrated that mentoring was strongly and significantly related to subsequent scientific collaboration, which supported a core design principle of the IRI. Future work should establish the link between mentoring and scientific productivity. These results may be of interest to team science, as they suggest the importance of mentoring for future team collaborations, as well as illustrate the utility of network analysis for studying team characteristics and activities.

  4. Glufosinate-ammonium

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Glufosinate - ammoni

  5. Fomesafen

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Fomesafen ; CASRN 72

  6. Pirimiphos-methyl

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Pirimiphos - methyl

  7. Bromoxynil

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Bromoxynil ; CASRN 1

  8. Prometryn

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Prometryn ; CASRN 72

  9. Linuron

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Linuron ; CASRN 330

  10. Dimethoate

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Dimethoate ; CASRN 6

  11. Methidathion

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Methidathion ; CASRN

  12. Phenmedipham

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Phenmedipham ; CASRN

  13. Pendimethalin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Pendimethalin ; CASR

  14. Chlorsulfuron

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Chlorsulfuron ; CASR

  15. Thiophanate-methyl

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Thiophanate - methyl

  16. Thiram

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Thiram ; CASRN 137 -

  17. Benefin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Benefin ; CASRN 1861

  18. Cyhalothrin/Karate

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Cyhalothrin / Karate

  19. Triallate

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Triallate ; CASRN 23

  20. Propiconazole

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Propiconazole ; CASR

  1. Chlorimuron-ethyl

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Chlorimuron - ethyl

  2. Cypermethrin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Cypermethrin ; CASRN

  3. Napropamide

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Napropamide ; CASRN

  4. Difenzoquat

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Difenzoquat ; CASRN

  5. Diphenylamine

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Diphenylamine ; CASR

  6. Harmony

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Harmony ; CASRN 7927

  7. Bidrin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Bidrin ; CASRN 141 -

  8. Pursuit

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Pursuit ; CASRN 8133

  9. Imazalil

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Imazalil ; CASRN 355

  10. Vinclozolin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Vinclozolin ; CASRN

  11. Chlorpropham

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Chlorpropham ; CASRN

  12. Bayleton

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Bayleton ; CASRN 431

  13. Propargite

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Propargite ; CASRN 2

  14. Oxyfluorfen

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Oxyfluorfen ; CASRN

  15. Amdro

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Amdro ; CASRN 67485

  16. Sethoxydim

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Sethoxydim ; CASRN 7

  17. Asulam

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Asulam ; CASRN 3337

  18. Norflurazon

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Norflurazon ; CASRN

  19. Dodine

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Dodine ; CASRN 2439

  20. Dimethipin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Dimethipin ; CASRN 5

  1. Bromoxynil octanoate

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Bromoxynil octanoate

  2. Folpet

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Folpet ; CASRN 133 -

  3. Flurprimidol

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Flurprimidol ; CASRN

  4. Oryzalin

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Oryzalin ; CASRN 190

  5. Lactofen

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Lactofen ; CASRN 775

  6. Flutolanil

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Flutolanil ; CASRN 6

  7. Acephate

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Acephate ; CASRN 305

  8. Development of IR imaging system simulator

    NASA Astrophysics Data System (ADS)

    Xiang, Xinglang; He, Guojing; Dong, Weike; Dong, Lu

    2017-02-01

    To overcome the disadvantages of the tradition semi-physical simulation and injection simulation equipment in the performance evaluation of the infrared imaging system (IRIS), a low-cost and reconfigurable IRIS simulator, which can simulate the realistic physical process of infrared imaging, is proposed to test and evaluate the performance of the IRIS. According to the theoretical simulation framework and the theoretical models of the IRIS, the architecture of the IRIS simulator is constructed. The 3D scenes are generated and the infrared atmospheric transmission effects are simulated using OGRE technology in real-time on the computer. The physical effects of the IRIS are classified as the signal response characteristic, modulation transfer characteristic and noise characteristic, and they are simulated on the single-board signal processing platform based on the core processor FPGA in real-time using high-speed parallel computation method.

  9. The IRIS Data Management Center: Enabling Access to Observational Time Series Spanning Decades

    NASA Astrophysics Data System (ADS)

    Ahern, T.; Benson, R.; Trabant, C.

    2009-04-01

    The Incorporated Research Institutions for Seismology (IRIS) is funded by the National Science Foundation (NSF) to operate the facilities to generate, archive, and distribute seismological data to research communities in the United States and internationally. The IRIS Data Management System (DMS) is responsible for the ingestion, archiving, curation and distribution of these data. The IRIS Data Management Center (DMC) manages data from more than 100 permanent seismic networks, hundreds of temporary seismic deployments as well as data from other geophysical observing networks such as magnetotelluric sensors, ocean bottom sensors, superconducting gravimeters, strainmeters, surface meteorological measurements, and in-situ atmospheric pressure measurements. The IRIS DMC has data from more than 20 different types of sensors. The IRIS DMC manages approximately 100 terabytes of primary observational data. These data are archived in multiple distributed storage systems that insure data availability independent of any single catastrophic failure. Storage systems include both RAID systems of greater than 100 terabytes as well as robotic tape robots of petabyte capacity. IRIS performs routine transcription of the data to new media and storage systems to insure the long-term viability of the scientific data. IRIS adheres to the OAIS Data Preservation Model in most cases. The IRIS data model requires the availability of metadata describing the characteristics and geographic location of sensors before data can be fully archived. IRIS works with the International Federation of Digital Seismographic Networks (FDSN) in the definition and evolution of the metadata. The metadata insures that the data remain useful to both current and future generations of earth scientists. Curation of the metadata and time series is one of the most important activities at the IRIS DMC. Data analysts and an automated quality assurance system monitor the quality of the incoming data. This insures data are of acceptably high quality. The formats and data structures used by the seismological community are esoteric. IRIS and its FDSN partners are developing web services that can transform the data holdings to structures that are more easily used by broader scientific communities. For instance, atmospheric scientists are interested in using global observations of microbarograph data but that community does not understand the methods of applying instrument corrections to the observations. Web processing services under development at IRIS will transform these data in a manner that allows direct use within such analysis tools as MATLAB® already in use by that community. By continuing to develop web-service based methods of data discovery and access, IRIS is enabling broader access to its data holdings. We currently support data discovery using many of the Open Geospatial Consortium (OGC) web mapping services. We are involved in portal technologies to support data discovery and distribution for all data from the EarthScope project. We are working with computer scientists at several universities including the University of Washington as part of a DataNet proposal and we intend to enhance metadata, further develop ontologies, develop a Registry Service to aid in the discovery of data sets and services, and in general improve the semantic interoperability of the data managed at the IRIS DMC. Finally IRIS has been identified as one of four scientific organizations that the External Research Division of Microsoft wants to work with in the development of web services and specifically with the development of a scientific workflow engine. More specific details of current and future developments at the IRIS DMC will be included in this presentation.

  10. A field study of the accuracy and reliability of a biometric iris recognition system.

    PubMed

    Latman, Neal S; Herb, Emily

    2013-06-01

    The iris of the eye appears to satisfy the criteria for a good anatomical characteristic for use in a biometric system. The purpose of this study was to evaluate a biometric iris recognition system: Mobile-Eyes™. The enrollment, verification, and identification applications were evaluated in a field study for accuracy and reliability using both irises of 277 subjects. Independent variables included a wide range of subject demographics, ambient light, and ambient temperature. A sub-set of 35 subjects had alcohol-induced nystagmus. There were 2710 identification and verification attempts, which resulted in 1,501,340 and 5540 iris comparisons respectively. In this study, the system successfully enrolled all subjects on the first attempt. All 277 subjects were successfully verified and identified on the first day of enrollment. None of the current or prior eye conditions prevented enrollment, verification, or identification. All 35 subjects with alcohol-induced nystagmus were successfully verified and identified. There were no false verifications or false identifications. Two conditions were identified that potentially could circumvent the use of iris recognitions systems in general. The Mobile-Eyes™ iris recognition system exhibited accurate and reliable enrollment, verification, and identification applications in this study. It may have special applications in subjects with nystagmus. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuxen, L.

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRISmore » contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).« less

  12. Fosetyl-al

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Fosetyl - al ; CASRN

  13. NuStar

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016NuStar ; CASRN 85509 -

  14. Merphos oxide

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) Merphos oxide ; CASR

  15. Video-based noncooperative iris image segmentation.

    PubMed

    Du, Yingzi; Arslanturk, Emrah; Zhou, Zhi; Belcher, Craig

    2011-02-01

    In this paper, we propose a video-based noncooperative iris image segmentation scheme that incorporates a quality filter to quickly eliminate images without an eye, employs a coarse-to-fine segmentation scheme to improve the overall efficiency, uses a direct least squares fitting of ellipses method to model the deformed pupil and limbic boundaries, and develops a window gradient-based method to remove noise in the iris region. A remote iris acquisition system is set up to collect noncooperative iris video images. An objective method is used to quantitatively evaluate the accuracy of the segmentation results. The experimental results demonstrate the effectiveness of this method. The proposed method would make noncooperative iris recognition or iris surveillance possible.

  16. IRIS Toxicological Review of Dichloromethane (Methylene ...

    EPA Pesticide Factsheets

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site

  17. Edge detection techniques for iris recognition system

    NASA Astrophysics Data System (ADS)

    Tania, U. T.; Motakabber, S. M. A.; Ibrahimy, M. I.

    2013-12-01

    Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate.

  18. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    EPA Pesticide Factsheets

    In January 2017, EPA finalized the IRIS assessment of Benzo[a]pyrene. The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  19. IRiS: construction of ARG networks at genomic scales.

    PubMed

    Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi

    2011-09-01

    Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.

  20. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    PubMed

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  1. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study

    PubMed Central

    Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.

    2017-01-01

    Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067

  2. S-Ethyl dipropylthiocarbamate (EPTC)

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) S - Ethyl dipropylth

  3. IRIS Toxicological Review of Ammonia Noncancer Inhalation ...

    EPA Pesticide Factsheets

    EPA has finalized the Integrated Risk Information System (IRIS) Assessment of Ammonia (Noncancer Inhalation). This assessment addresses the potential noncancer human health effects from long-term inhalation exposure to ammonia. Now final, this assessment will update the current toxicological information on ammonia posted in 1991. EPA’s program and regional offices may use this assessment to inform decisions to protect human health. EPA completed the Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  4. Secure and Robust Iris Recognition Using Random Projections and Sparse Representations.

    PubMed

    Pillai, Jaishanker K; Patel, Vishal M; Chellappa, Rama; Ratha, Nalini K

    2011-09-01

    Noncontact biometrics such as face and iris have additional benefits over contact-based biometrics such as fingerprint and hand geometry. However, three important challenges need to be addressed in a noncontact biometrics-based authentication system: ability to handle unconstrained acquisition, robust and accurate matching, and privacy enhancement without compromising security. In this paper, we propose a unified framework based on random projections and sparse representations, that can simultaneously address all three issues mentioned above in relation to iris biometrics. Our proposed quality measure can handle segmentation errors and a wide variety of possible artifacts during iris acquisition. We demonstrate how the proposed approach can be easily extended to handle alignment variations and recognition from iris videos, resulting in a robust and accurate system. The proposed approach includes enhancements to privacy and security by providing ways to create cancelable iris templates. Results on public data sets show significant benefits of the proposed approach.

  5. Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS

    PubMed Central

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc

    2014-01-01

    Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients. Methods In a prospective cohort study of HIV-TB co-infected patients treated for TB before ART initiation, we compared 18 patients who developed TB-IRIS with 18 non-IRIS controls matched for age, sex and CD4 count. We analyzed IFNγ ELISpot responses to CMV, influenza, TB and LPS before ART and during TB-IRIS. CMV and LPS stimulated ELISpot supernatants were subsequently evaluated for production of IL-12p70, IL-6, TNFα and IL-10 by Luminex. Results Before ART, all responses were similar between TB-IRIS patients and non-IRIS controls. During TB-IRIS, IFNγ responses to TB and influenza antigens were comparable between TB-IRIS patients and non-IRIS controls, but responses to CMV and LPS remained significantly lower in TB-IRIS patients. Production of innate cytokines was similar between TB-IRIS patients and non-IRIS controls. However, upon LPS stimulation, IL-6/IL-10 and TNFα/IL-10 ratios were increased in TB-IRIS patients compared to non-IRIS controls. Conclusion TB-IRIS patients did not display excessive IFNγ responses to TB-antigens. In contrast, the reconstitution of CMV and LPS responses was delayed in the TB-IRIS group. For LPS, this was linked with a pro-inflammatory shift in the innate cytokine balance. These data are in support of a prominent role of the innate immune system in TB-IRIS. PMID:25415590

  6. Characterization and Fate of Gun and Rocket Propellant Residues on Testing and Training Ranges

    DTIC Science & Technology

    2008-01-01

    ext/reg_e.html. 36. United States Environmental Protection Agency (2007) Integrated Risk Information System: Hydrogen cyanide, http://www.epa.gov/ iris ...Environmental Protection Agency (2007) Integrated Risk Information System: Benzene, http://www.epa.gov/ iris /subst/0276.htm 42. United States Environmental...Protection Agency (2007) Integrated Risk Information System: Toluene, http://www.epa.gov/ iris /subst/0118.htm. 43. National Library of Medicine’s TOXNET

  7. IRIS: Supporting & Managing the Research Life-Cycle

    ERIC Educational Resources Information Center

    Bollini, Andrea; Mennielli, Michele; Mornati, Susanna; Palmer, David T.

    2016-01-01

    IRIS is a new Current Research Information System (CRIS) developed by Cineca to upgrade and replace two previous solutions that have been used by Italian universities in the last 10 years. At the end of 2015, sixty-three Italian institutions are using IRIS. One of the main components of IRIS is DSpace-CRIS, an open source solution that can also be…

  8. Extended depth of field system for long distance iris acquisition

    NASA Astrophysics Data System (ADS)

    Chen, Yuan-Lin; Hsieh, Sheng-Hsun; Hung, Kuo-En; Yang, Shi-Wen; Li, Yung-Hui; Tien, Chung-Hao

    2012-10-01

    Using biometric signatures for identity recognition has been practiced for centuries. Recently, iris recognition system attracts much attention due to its high accuracy and high stability. The texture feature of iris provides a signature that is unique for each subject. Currently most commercial iris recognition systems acquire images in less than 50 cm, which is a serious constraint that needs to be broken if we want to use it for airport access or entrance that requires high turn-over rate . In order to capture the iris patterns from a distance, in this study, we developed a telephoto imaging system with image processing techniques. By using the cubic phase mask positioned front of the camera, the point spread function was kept constant over a wide range of defocus. With adequate decoding filter, the blurred image was restored, where the working distance between the subject and the camera can be achieved over 3m associated with 500mm focal length and aperture F/6.3. The simulation and experimental results validated the proposed scheme, where the depth of focus of iris camera was triply extended over the traditional optics, while keeping sufficient recognition accuracy.

  9. The best bits in an iris code.

    PubMed

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2009-06-01

    Iris biometric systems apply filters to iris images to extract information about iris texture. Daugman's approach maps the filter output to a binary iris code. The fractional Hamming distance between two iris codes is computed and decisions about the identity of a person are based on the computed distance. The fractional Hamming distance weights all bits in an iris code equally. However, not all the bits in an iris code are equally useful. Our research is the first to present experiments documenting that some bits are more consistent than others. Different regions of the iris are compared to evaluate their relative consistency, and contrary to some previous research, we find that the middle bands of the iris are more consistent than the inner bands. The inconsistent-bit phenomenon is evident across genders and different filter types. Possible causes of inconsistencies, such as segmentation, alignment issues, and different filters are investigated. The inconsistencies are largely due to the coarse quantization of the phase response. Masking iris code bits corresponding to complex filter responses near the axes of the complex plane improves the separation between the match and nonmatch Hamming distance distributions.

  10. IRIS Toxicological Review of Naphthalene (1998 Final)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of Naphthalene: in support of the Integrated Risk Information System (IRIS). The updated Summary for Naphthalene and accompanying toxicological review have been added to the IRIS Database.

  11. IRIS Toxicological Review of Phosgene (Final Report)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of Phosgene: in support of the Integrated Risk Information System (IRIS). The updated Summary for Phosgene and accompanying toxicological review have been added to the IRIS Database.

  12. IRIS Toxicological Review of Acrolein (2003 Final)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of Acrolein: in support of the Integrated Risk Information System (IRIS). The updated Summary for Acrolein and accompanying toxicological review have been added to the IRIS Database.

  13. IRIS Toxicological Review of Chloroform (Final Report)

    EPA Science Inventory

    EPA is announcing the release of the final report, Toxicological Review of Chloroform: in support of the Integrated Risk Information System (IRIS). The updated Summary for Chloroform and accompanying Quickview have also been added to the IRIS Database.

  14. An Iris Segmentation Algorithm based on Edge Orientation for Off-angle Iris Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J

    Iris recognition is known as one of the most accurate and reliable biometrics. However, the accuracy of iris recognition systems depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. In this paper, we present a segmentation algorithm for off-angle iris images that uses edge detection, edge elimination, edge classification, and ellipse fitting techniques. In our approach, we first detect all candidate edges in the iris image by using the canny edge detector; this collection contains edges from the iris and pupil boundaries as well as eyelash, eyelids, iris texturemore » etc. Edge orientation is used to eliminate the edges that cannot be part of the iris or pupil. Then, we classify the remaining edge points into two sets as pupil edges and iris edges. Finally, we randomly generate subsets of iris and pupil edge points, fit ellipses for each subset, select ellipses with similar parameters, and average to form the resultant ellipses. Based on the results from real experiments, the proposed method shows effectiveness in segmentation for off-angle iris images.« less

  15. Toward noncooperative iris recognition: a classification approach using multiple signatures.

    PubMed

    Proença, Hugo; Alexandre, Luís A

    2007-04-01

    This paper focuses on noncooperative iris recognition, i.e., the capture of iris images at large distances, under less controlled lighting conditions, and without active participation of the subjects. This increases the probability of capturing very heterogeneous images (regarding focus, contrast, or brightness) and with several noise factors (iris obstructions and reflections). Current iris recognition systems are unable to deal with noisy data and substantially increase their error rates, especially the false rejections, in these conditions. We propose an iris classification method that divides the segmented and normalized iris image into six regions, makes an independent feature extraction and comparison for each region, and combines each of the dissimilarity values through a classification rule. Experiments show a substantial decrease, higher than 40 percent, of the false rejection rates in the recognition of noisy iris images.

  16. An automatic iris occlusion estimation method based on high-dimensional density estimation.

    PubMed

    Li, Yung-Hui; Savvides, Marios

    2013-04-01

    Iris masks play an important role in iris recognition. They indicate which part of the iris texture map is useful and which part is occluded or contaminated by noisy image artifacts such as eyelashes, eyelids, eyeglasses frames, and specular reflections. The accuracy of the iris mask is extremely important. The performance of the iris recognition system will decrease dramatically when the iris mask is inaccurate, even when the best recognition algorithm is used. Traditionally, people used the rule-based algorithms to estimate iris masks from iris images. However, the accuracy of the iris masks generated this way is questionable. In this work, we propose to use Figueiredo and Jain's Gaussian Mixture Models (FJ-GMMs) to model the underlying probabilistic distributions of both valid and invalid regions on iris images. We also explored possible features and found that Gabor Filter Bank (GFB) provides the most discriminative information for our goal. Finally, we applied Simulated Annealing (SA) technique to optimize the parameters of GFB in order to achieve the best recognition rate. Experimental results show that the masks generated by the proposed algorithm increase the iris recognition rate on both ICE2 and UBIRIS dataset, verifying the effectiveness and importance of our proposed method for iris occlusion estimation.

  17. IRIS Toxicological Review of Decabromodiphenyl Ether (Final Report)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of Decabromodiphenyl Ether: in support of the Integrated Risk Information System (IRIS). The updated Summary for Decabromodiphenyl Ether and accompanying toxicological review have been added to the IRIS Da...

  18. 4-(2-Methyl-4-chlorophenoxy) butyric acid (MCPB)

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) 4 - ( 2 - Methyl - 4

  19. Developmental validation of the IrisPlex system: determination of blue and brown iris colour for forensic intelligence.

    PubMed

    Walsh, Susan; Lindenbergh, Alexander; Zuniga, Sofia B; Sijen, Titia; de Knijff, Peter; Kayser, Manfred; Ballantyne, Kaye N

    2011-11-01

    The IrisPlex system consists of a highly sensitive multiplex genotyping assay together with a statistical prediction model, providing users with the ability to predict blue and brown human eye colour from DNA samples with over 90% precision. This 'DNA intelligence' system is expected to aid police investigations by providing phenotypic information on unknown individuals when conventional DNA profiling is not informative. Falling within the new area of forensic DNA phenotyping, this paper describes the developmental validation of the IrisPlex assay following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for the application of DNA-based eye colour prediction to forensic casework. The IrisPlex assay produces complete SNP genotypes with only 31pg of DNA, approximately six human diploid cell equivalents, and is therefore more sensitive than commercial STR kits currently used in forensics. Species testing revealed human and primate specificity for a complete SNP profile. The assay is capable of producing accurate results from simulated casework samples such as blood, semen, saliva, hair, and trace DNA samples, including extremely low quantity samples. Due to its design, it can also produce full profiles with highly degraded samples often found in forensic casework. Concordance testing between three independent laboratories displayed reproducible results of consistent levels on varying types of simulated casework samples. With such high levels of sensitivity, specificity, consistency and reliability, this genotyping assay, as a core part of the IrisPlex system, operates in accordance with SWGDAM guidelines. Furthermore, as we demonstrated previously, the IrisPlex eye colour prediction system provides reliable results without the need for knowledge on the bio-geographic ancestry of the sample donor. Hence, the IrisPlex system, with its model-based prediction probability estimation of blue and brown human eye colour, represents a useful tool for immediate application in accredited forensic laboratories, to be used for forensic intelligence in tracing unknown individuals from crime scene samples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. IRIS Toxicological Review of Trimethylbenzenes (Final Report)

    EPA Science Inventory

    EPA has finalized the Integrated Risk Information System (IRIS) Assessment of Trimethylbenzenes (TMBs). This assessment addresses the potential non-cancer and cancer human health effects from long-term exposure to TMBs. Now final, this assessment will be the first IRIS a...

  1. 4-(2,4-Dichlorophenoxy)butyric acid (2,4-DB)

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) 4 - ( 2,4 - Dichloro

  2. IRIS Toxicological Review of 2-Methylnaphthalene (2003, Final)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of 2-Methylnaphthalene: in support of the Integrated Risk Information System (IRIS). The updated Summary for 2-Methylnaphthalene and accompanying toxicological review have also been added to the IRIS Datab...

  3. IRIS Toxicological Review of Vinyl Chloride (Final Report, 2000)

    EPA Science Inventory

    EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database.

  4. Real-time image restoration for iris recognition systems.

    PubMed

    Kang, Byung Jun; Park, Kang Ryoung

    2007-12-01

    In the field of biometrics, it has been reported that iris recognition techniques have shown high levels of accuracy because unique patterns of the human iris, which has very many degrees of freedom, are used. However, because conventional iris cameras have small depth-of-field (DOF) areas, input iris images can easily be blurred, which can lead to lower recognition performance, since iris patterns are transformed by the blurring caused by optical defocusing. To overcome these problems, an autofocusing camera can be used. However, this inevitably increases the cost, size, and complexity of the system. Therefore, we propose a new real-time iris image-restoration method, which can increase the camera's DOF without requiring any additional hardware. This paper presents five novelties as compared to previous works: 1) by excluding eyelash and eyelid regions, it is possible to obtain more accurate focus scores from input iris images; 2) the parameter of the point spread function (PSF) can be estimated in terms of camera optics and measured focus scores; therefore, parameter estimation is more accurate than it has been in previous research; 3) because the PSF parameter can be obtained by using a predetermined equation, iris image restoration can be done in real-time; 4) by using a constrained least square (CLS) restoration filter that considers noise, performance can be greatly enhanced; and 5) restoration accuracy can also be enhanced by estimating the weight value of the noise-regularization term of the CLS filter according to the amount of image blurring. Experimental results showed that iris recognition errors when using the proposed restoration method were greatly reduced as compared to those results achieved without restoration or those achieved using previous iris-restoration methods.

  5. [Neuropathology of Natalizumab-Associated Progressive Multifocal Leukoencephalopathy].

    PubMed

    Kanda, Takashi

    2015-07-01

    The pathological findings of natalizumab-associated progressive multifocal leukoencephalopathy (PML) are reviewed. In addition to the classical pathology of PML including the presence of enlarged abnormal astrocytes, intranuclear inclusions mainly found within large swollen oligodendrocytes and abundant myelin-laden macrophages/microglia, massive perivascular and parenchymal mononuclear cell infiltration was observed. The latter pathologic picture is that of immune reconstitution inflammatory syndrome (IRIS), and most of these infiltrating cells are CD8-positive T cells. Because IRIS inevitably occurs after the cessation of natalizumab therapy due to the development of PML and subsequent plasma exchange, most of the published pathologic pictures of natalizumab-associated PML patients were a mixture of PML and PML-IRIS. PML-IRIS is also characterized by fewer oligodendroglial viral inclusions and fewer cells that are immunoreactive against anti-JCV antibodies. These findings suggest the effective removal of JCV after the return of normal immune-surveillance in the central nervous system, but clinicians should be aware that JCV elimination is not complete under the IRIS condition, and the immunosuppressive therapy against IRIS should be carefully performed. Mononuclear cell infiltration in natalizumab-associated PML-IRIS patients was much more prominent than that in HIV-associated PML-IRIS patients, reflecting the retained, even enhanced, systemic immunities in patients treated by natalizumab.

  6. IRIS Toxicological Review of Methyl Ethyl Ketone (2003 Final)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of Methyl Ethyl Ketone: in support of the Integrated Risk Information System (IRIS). The updated Summary for Methyl Ethyl Ketone and accompanying toxicological review have been added to the IRIS Database....

  7. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR CHLORDECONE (KEPONE) (2009 FINAL)

    EPA Science Inventory

    EPA is announcing the release of the final report, Toxicological Review of Chlorodecone (kepone): in support of the Integrated Risk Information System (IRIS). The updated Summary for Chlordecone (kepone) and accompanying Quickview have also been added to the IRIS Database....

  8. The UBIRIS.v2: a database of visible wavelength iris images captured on-the-move and at-a-distance.

    PubMed

    Proença, Hugo; Filipe, Sílvio; Santos, Ricardo; Oliveira, João; Alexandre, Luís A

    2010-08-01

    The iris is regarded as one of the most useful traits for biometric recognition and the dissemination of nationwide iris-based recognition systems is imminent. However, currently deployed systems rely on heavy imaging constraints to capture near infrared images with enough quality. Also, all of the publicly available iris image databases contain data correspondent to such imaging constraints and therefore are exclusively suitable to evaluate methods thought to operate on these type of environments. The main purpose of this paper is to announce the availability of the UBIRIS.v2 database, a multisession iris images database which singularly contains data captured in the visible wavelength, at-a-distance (between four and eight meters) and on on-the-move. This database is freely available for researchers concerned about visible wavelength iris recognition and will be useful in accessing the feasibility and specifying the constraints of this type of biometric recognition.

  9. 2014 Summer Series - Robert Carvalho - Pursuing the Mysteries of the Sun: The IRIS Mission

    NASA Image and Video Library

    2014-06-19

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRIS's mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  10. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    NASA Astrophysics Data System (ADS)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  11. The Infrared Imaging Spectrograph (IRIS) for TMT: multi-tiered wavefront measurements and novel mechanical design

    NASA Astrophysics Data System (ADS)

    Dunn, Jennifer; Andersen, David; Chapin, Edward; Reshetov, Vlad; Wierzbicki, Ramunas; Herriot, Glen; Chalmer, Dean; Isbrucker, Victor; Larkin, James E.; Moore, Anna M.; Suzuki, Ryuji

    2016-08-01

    The InfraRed Imaging Spectrograph (IRIS) will be the first light adaptive optics instrument on the Thirty Meter Telescope (TMT). IRIS is being built by a collaboration between Caltech, the University of California, NAOJ and NRC Herzberg. In this paper we present novel aspects of the Support Structure, Rotator and On-Instrument Wavefront Sensor systems being developed at NRC Herzberg. IRIS is suspended from the bottom port of the Narrow Field Infrared Adaptive Optics System (NFIRAOS), and provides its own image de-rotation to compensate for sidereal rotation of the focal plane. This arrangement is a challenge because NFIRAOS is designed to host two other science instruments, which imposes strict mass requirements on IRIS. As the mechanical design of all elements has progressed, we have been tasked with keeping the instrument mass under seven tonnes. This requirement has resulted in a mass reduction of 30 percent for the support structure and rotator compared to the most recent IRIS designs. To accomplish this goal, while still being able to withstand earthquakes, we developed a new design with composite materials. As IRIS is a client instrument of NFIRAOS, it benefits from NFIRAOS's superior AO correction. IRIS plays an important role in providing this correction by sensing low-order aberrations with three On-Instrument Wavefront Sensors (OIWFS). The OIWFS consists of three independently positioned natural guide star wavefront sensor probe arms that patrol a 2-arcminute field of view. We expect tip-tilt measurements from faint stars within the IRIS imager focal plane will further stabilize the delivered image quality. We describe how the use of On-Detector Guide Windows (ODGWs) in the IRIS imaging detector can be incorporated into the AO correction. In this paper, we present our strategies for acquiring and tracking sources with this complex AO system, and for mitigating and measuring the various potential sources of image blur and misalignment due to properties of the mechanical structure and interfaces.

  12. HIV Immune Recovery Inflammatory Syndrome and Central Nervous System Paracoccidioidomycosis.

    PubMed

    de Almeida, Sérgio Monteiro; Roza, Thiago Henrique

    2017-04-01

    The immune reconstitution inflammatory syndrome (IRIS) is a deregulated inflammatory response to invading microorganisms. It is manifested when there is an abrupt change in host immunity from an anti-inflammatory and immunosuppressive state to a pro-inflammatory state as a result of rapid depletion or removal of factors that promote immune suppression or inhibition of inflammation. The aim of this paper is to discuss and re-interpret the possibility of association of paracoccidioidomycosis (PCM) with IRIS in the central nervous system (CNS) in a case from Brazil published by Silva-Vergara ML. et al. (Mycopathologia 177:137-141, 6). An AIDS patient who was not receiving medical care developed pulmonary PCM successfully treated with itraconazole. The patient developed central nervous system PCM (NPCM) after starting the ARV therapy with recovery of immunity and control of HIV viral load, although it was not interpreted as IRIS by the authors, it fulfills the criteria for CNS IRIS. This could be the first case of NPCM associated with IRIS described. Although not frequent, IRIS must be considered in PCM patients and HIV, from endemic areas or patients that traveled to endemic areas, receiving ARV treatment and with worsening symptoms.

  13. Iris metastasis as a first manifestation of lung adenocarcinoma.

    PubMed

    Hernández-Da Mota, S E; Ulaje-Nuñez, J M; Salinas-Gallegos, J L; Rodríguez-Reyes, A

    2018-03-23

    To describe a case of lung adenocarcinoma for which the first clinical manifestation was an iris metastasis. A 76-year-old male patient came for consultation referring a «pinkish speck» on his right eye. On biomicroscopy examination, a mass was found on the iris of the right eye. Subsequent systemic work-up of the patient revealed a left lung adenocarcinoma. Although uncommon, iris metastasis secondary to lung cancer should be part of differential diagnosis in iris tumours. Copyright © 2018 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Extending the imaging volume for biometric iris recognition.

    PubMed

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  15. NATIONAL PREPAREDNESS: Integrating New and Existing Technology and Information Sharing into an Effective Homeland Security Strategy

    DTIC Science & Technology

    2002-06-07

    Continue to Develop and Refine Emerging Technology • Some of the emerging biometric devices, such as iris scans and facial recognition systems...such as iris scans and facial recognition systems, facial recognition systems, and speaker verification systems. (976301)

  16. U.S. EPA'S IRIS ASSESSMENT OF 2-BUTOXYETHANOL: THE RELATIONSHIP OF NONCANCER TO CANCER EFFECTS

    EPA Science Inventory

    U.S. EPA's current IRIS (Integrated Risk Information System; www.epa.gov/IRIS) assessment of 2-butoxyethanol (EGBE; CASRN 11-76-2) identifies hemolytic effects in laboratory exposed animals as the critical noncancer endpoint. This noncancer (and nonlinear) endpoint forms the b...

  17. Method of preliminary localization of the iris in biometric access control systems

    NASA Astrophysics Data System (ADS)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  18. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (Public Comment Draft)

    EPA Science Inventory

    EPA is developing an Integrated Risk Information System (IRIS) assessment of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and has released the draft assessment for public comment. When final, the assessment will appear on the IRIS database.

  19. A novel in vivo model of puncture-induced iris neovascularization.

    PubMed

    Beaujean, Ophélie; Locri, Filippo; Aronsson, Monica; Kvanta, Anders; André, Helder

    2017-01-01

    To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances.

  20. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (Etbe) ...

    EPA Pesticide Factsheets

    In September 2016, EPA released the draft IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) for public comment and discussion. The draft assessment was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Ethyl Tertiary Butyl Ether are posted on this site. EPA is undertaking an new health assessment for ethyl tertiary butyl ether (ETBE) for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS Summary of ETBE that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used nationally and internationally in combination with specific situational exposure assessment infor

  1. Technical issues for the eye image database creation at distance

    NASA Astrophysics Data System (ADS)

    Oropesa Morales, Lester Arturo; Maldonado Cano, Luis Alejandro; Soto Aldaco, Andrea; García Vázquez, Mireya Saraí; Zamudio Fuentes, Luis Miguel; Rodríguez Vázquez, Manuel Antonio; Pérez Rosas, Osvaldo Gerardo; Rodríguez Espejo, Luis; Montoya Obeso, Abraham; Ramírez Acosta, Alejandro Álvaro

    2016-09-01

    Biometrics refers to identify people through their physical characteristics or behavior such as fingerprints, face, DNA, hand geometries, retina and iris patterns. Typically, the iris pattern is to acquire in short distance to recognize a person, however, in the past few years is a challenge identify a person by its iris pattern at certain distance in non-cooperative environments. This challenge comprises: 1) high quality iris image, 2) light variation, 3) blur reduction, 4) specular reflections reduction, 5) the distance from the acquisition system to the user, and 6) standardize the iris size and the density pixel of iris texture. The solution of the challenge will add robustness and enhance the iris recognition rates. For this reason, we describe the technical issues that must be considered during iris acquisition. Some of these considerations are the camera sensor, lens, the math analysis of depth of field (DOF) and field of view (FOV) for iris recognition. Finally, based on this issues we present experiment that show the result of captures obtained with our camera at distance and captures obtained with cameras in very short distance.

  2. A Statistical Analysis of IrisCode and Its Security Implications.

    PubMed

    Kong, Adams Wai-Kin

    2015-03-01

    IrisCode has been used to gather iris data for 430 million people. Because of the huge impact of IrisCode, it is vital that it is completely understood. This paper first studies the relationship between bit probabilities and a mean of iris images (The mean of iris images is defined as the average of independent iris images.) and then uses the Chi-square statistic, the correlation coefficient and a resampling algorithm to detect statistical dependence between bits. The results show that the statistical dependence forms a graph with a sparse and structural adjacency matrix. A comparison of this graph with a graph whose edges are defined by the inner product of the Gabor filters that produce IrisCodes shows that partial statistical dependence is induced by the filters and propagates through the graph. Using this statistical information, the security risk associated with two patented template protection schemes that have been deployed in commercial systems for producing application-specific IrisCodes is analyzed. To retain high identification speed, they use the same key to lock all IrisCodes in a database. The belief has been that if the key is not compromised, the IrisCodes are secure. This study shows that even without the key, application-specific IrisCodes can be unlocked and that the key can be obtained through the statistical dependence detected.

  3. Immunopathology of immune reconstitution inflammatory syndrome in Whipple's disease.

    PubMed

    Moos, Verena; Feurle, Gerhard E; Schinnerling, Katina; Geelhaar, Anika; Friebel, Julian; Allers, Kristina; Moter, Annette; Kikhney, Judith; Loddenkemper, Christoph; Kühl, Anja A; Erben, Ulrike; Fenollar, Florence; Raoult, Didier; Schneider, Thomas

    2013-03-01

    During antimicrobial treatment of classic Whipple's disease (CWD), the chronic systemic infection with Tropheryma whipplei, immune reconstitution inflammatory syndrome (IRIS), is a serious complication. The aim of our study was to characterize the immunological processes underlying IRIS in CWD. Following the definition of IRIS, we describe histological features of IRIS and immunological parameters of 24 CWD IRIS patients, 189 CWD patients without IRIS, and 89 healthy individuals. T cell reconstitution, Th1 reactivity, and the phenotype of T cells were described in the peripheral blood, and infiltration of CD4(+) T cells and regulatory T cells in the duodenal mucosa was determined. During IRIS, tissues were heavily infiltrated by CD3(+), predominantly CD45RO(+)CD4(+) T cells. In the periphery, initial reduction of CD4(+) cell counts and their reconstitution on treatment was more pronounced in CWD patients with IRIS than in those without IRIS. The ratio of activated and regulatory CD4(+) T cells, nonspecific Th1 reactivity, and the proportion of naive among CD4(+) T cells was high, whereas serum IL-10 was low during IRIS. T. whipplei-specific Th1 reactivity remained suppressed before and after emergence of IRIS. The findings that IRIS in CWD mainly are mediated by nonspecific activation of CD4(+) T cells and that it is not sufficiently counterbalanced by regulatory T cells indicate that flare-up of pathogen-specific immunoreactivity is not instrumental in the pathogenesis of IRIS in CWD.

  4. Deep learning architecture for iris recognition based on optimal Gabor filters and deep belief network

    NASA Astrophysics Data System (ADS)

    He, Fei; Han, Ye; Wang, Han; Ji, Jinchao; Liu, Yuanning; Ma, Zhiqiang

    2017-03-01

    Gabor filters are widely utilized to detect iris texture information in several state-of-the-art iris recognition systems. However, the proper Gabor kernels and the generative pattern of iris Gabor features need to be predetermined in application. The traditional empirical Gabor filters and shallow iris encoding ways are incapable of dealing with such complex variations in iris imaging including illumination, aging, deformation, and device variations. Thereby, an adaptive Gabor filter selection strategy and deep learning architecture are presented. We first employ particle swarm optimization approach and its binary version to define a set of data-driven Gabor kernels for fitting the most informative filtering bands, and then capture complex pattern from the optimal Gabor filtered coefficients by a trained deep belief network. A succession of comparative experiments validate that our optimal Gabor filters may produce more distinctive Gabor coefficients and our iris deep representations be more robust and stable than traditional iris Gabor codes. Furthermore, the depth and scales of the deep learning architecture are also discussed.

  5. The International Reference Ionosphere - Status 2013

    NASA Astrophysics Data System (ADS)

    Bilitza, Dieter

    2015-04-01

    This paper describes the latest version of the International Reference Ionosphere (IRI) model. IRI-2012 includes new models for the electron density and ion densities in the region below the F-peak, a storm-time model for the auroral E-region, an improved electron temperature model that includes variations with solar activity, and for the first time a description of auroral boundaries. In addition, the thermosphere model required for baseline neutral densities and temperatures was upgraded from MSIS-86 to the newer NRLMSIS-00 model and Corrected Geomagnetic coordinates (CGM) were included in IRI as an additional coordinate system for a better representation of auroral and polar latitudes. Ongoing IRI activities towards the inclusion of an improved model for the F2 peak height hmF2 are discussed as are efforts to develop a "Real-Time IRI". The paper is based on an IRI status report presented at the 2013 IRI Workshop in Olsztyn, Poland. The IRI homepage is at

  6. Energy-efficient lighting system for television

    DOEpatents

    Cawthorne, Duane C.

    1987-07-21

    A light control system for a television camera comprises an artificial light control system which is cooperative with an iris control system. This artificial light control system adjusts the power to lamps illuminating the camera viewing area to provide only sufficient artificial illumination necessary to provide a sufficient video signal when the camera iris is substantially open.

  7. Optimal wavelength band clustering for multispectral iris recognition.

    PubMed

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  8. Exploration of the impacts of distributed-site Research Experiences for Undergraduates using pre-/post- student interviews

    NASA Astrophysics Data System (ADS)

    Colella, H.; Hubenthal, M.; Brudzinski, M. R.

    2013-12-01

    The benefits for student participants of undergraduate research opportunities have been well documented. However, advancements in information and communications technologies (ICT) and cultural shifts around online education and virtual peer-to-peer interaction have lead to new models in which to structure such experiences. Currently, these ICT-enabled Research Experiences for Undergraduates (REU) programs connect geographically distributed interns in supportive e-learning communities while maintaining a traditional local mentoring arrangement. To document and explore the effects of distributed REU Sites in more depth, six interns from such a program, the Incorporated Research Institution for Seismology (IRIS) REU, were selected at random and asked to be interviewed about the REU experience. The primary targets of the interviews are to understand the mentor/mentee relationships, feeling of support and development and value of near-peer and far-peer relationships throughout their internship in a distributed REU program, and whether they receive the training necessary to gain confidence as a researcher. We also examine the various communication technologies as well as best practices and strategies that can increase intern connectedness. Pre-internship interviews were conducted in-person at the start of the centralized internship orientation week, while post-internship interviews were virtual (e.g. video chat with Skype or Google Hangout). These semi-structured interviews have full audio recordings and subsequent transcriptions. An additional, virtual follow-up interview will be conducted next spring after the interns have an opportunity to attend and present their research at a national conference (e.g., AGU). Interview material will be analyzed through a process of coding, sorting, local integration, and inclusive integration. Results will also be triangulated with pre- and post- survey data both from participants and other survey data from previous years of the IRIS program. Our presentation will highlight the key findings of these analyses. GeoCorps and RESESS will begin to employ this interview style assessment beginning this fall and next year, respectively, which will facilitate detailed comparisons between distributed and non-distributed REU approaches.

  9. IRIS Mission Operations Director's Colloquium

    NASA Technical Reports Server (NTRS)

    Carvalho, Robert; Mazmanian, Edward A.

    2014-01-01

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRISs mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  10. Evaluation of iris recognition system for wavefront-guided laser in situ keratomileusis for myopic astigmatism.

    PubMed

    Ghosh, Sudipta; Couper, Terry A; Lamoureux, Ecosse; Jhanji, Vishal; Taylor, Hugh R; Vajpayee, Rasik B

    2008-02-01

    To evaluate the visual and refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) using an iris recognition system for the correction of myopic astigmatism. Centre for Eye Research Australia, Melbourne Excimer Laser Research Group, and Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. A comparative analysis of wavefront-guided LASIK was performed with an iris recognition system (iris recognition group) and without iris recognition (control group). The main parameters were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, amount of residual cylinder, manifest spherical equivalent (SE), and the index of success using the Alpins method of astigmatism analysis 1 and 3 months postoperatively. A P value less than 0.05 was considered statistically significant. Preoperatively, the mean SE was -4.32 diopters (D) +/- 1.59 (SD) in the iris recognition group (100 eyes) and -4.55 +/- 1.87 D in the control group (98 eyes) (P = .84). At 3 months, the mean SE was -0.05 +/- 0.21 D and -0.20 +/- 0.40 D, respectively (P = .001), and an SE within +/-0.50 D of emmetropia was achieved in 92.0% and 85.7% of eyes, respectively (P = .07). At 3 months, the UCVA was 20/20 or better in 90.0% and 76.5% of eyes, respectively. A statistically significant difference in the amount of astigmatic correction was seen between the 2 groups (P = .00 and P = .01 at 1 and 3 months, respectively). The index of success was 98.0% in the iris recognition group and 81.6% in the control group (P = .03). Iris recognition software may achieve better visual and refractive outcomes in wavefront-guided LASIK for myopic astigmatism.

  11. New methods in iris recognition.

    PubMed

    Daugman, John

    2007-10-01

    This paper presents the following four advances in iris recognition: 1) more disciplined methods for detecting and faithfully modeling the iris inner and outer boundaries with active contours, leading to more flexible embedded coordinate systems; 2) Fourier-based methods for solving problems in iris trigonometry and projective geometry, allowing off-axis gaze to be handled by detecting it and "rotating" the eye into orthographic perspective; 3) statistical inference methods for detecting and excluding eyelashes; and 4) exploration of score normalizations, depending on the amount of iris data that is available in images and the required scale of database search. Statistical results are presented based on 200 billion iris cross-comparisons that were generated from 632500 irises in the United Arab Emirates database to analyze the normalization issues raised in different regions of receiver operating characteristic curves.

  12. The Priority of Road Rehabilitation in Karanganyar Regency Using IRI Estimation from Roadroid

    NASA Astrophysics Data System (ADS)

    Achmadi, F.; Suprapto, M.; Setyawan, A.

    2017-02-01

    The IRI (International Roughness Index) is a road roughness index commonly obtained from measured longitudinal road profiles. This is one of the functional performance a surface of road pavement. Therefore, needs to be done evaluation and monitoring periodically to getting priority of road rehabilitation right on target. The IRI standard has commonly been used worldwide for evaluating road system. The Roadroid is an application to measure road quality with a website to view road quality. It is designed for Android smartphones, so we can easily measure and monitor the road and also use the camera for GPS-tagged photo. By using the built-in vibration sensor in smartphones, it is possible to collect IRI value which can be an indicator road conditions. This study attempts to explain the priority of road rehabilitation in Karanganyar Regency. The location of the study focused on a collector street (primary, secondary and locally road). The result of IRI estimation will be combined with other aspects that influences; land use, policy, the connectivity of road and traffic average daily. Based on IRI estimation using Roadroid, the road conditions in Karanganyar Regency can be described 59,60% were good (IRI<4,5) 21,30% fair (4,512).

  13. A novel in vivo model of puncture-induced iris neovascularization

    PubMed Central

    Aronsson, Monica; Kvanta, Anders

    2017-01-01

    Purpose To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Methods Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Results Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. Conclusions This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances. PMID:28658313

  14. IRIS Toxicological Review of Ammonia Noncancer Inhalation ...

    EPA Pesticide Factsheets

    In September 2016, EPA finalized the IRIS assessment of Ammonia (Noncancer Inhalation). The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release in June 2016. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Ammonia (Noncancer Inhalation) are posted on this site. Note: No major science comments were received on the Interagency Science Discussion Draft. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  15. Iridoschisis: high frequency ultrasound imaging. Evidence for a genetic defect?

    PubMed Central

    Danias, J; Aslanides, I M; Eichenbaum, J W; Silverman, R H; Reinstein, D Z; Coleman, D J

    1996-01-01

    AIMS: To elucidate changes in the anatomy of the anterior chamber associated with iridoschisis, a rare form of iris atrophy, and their potential contribution to angle closure glaucoma. METHODS: Both eyes of a 71-year-old woman with bilateral iridoschisis and fibrous dysplasia and her asymptomatic 50-year-old daughter were scanned with a very high frequency (50 MHz) ultrasound system. RESULTS: The symptomatic patient exhibited diffuse changes in the iris stoma with an intact posterior iris pigmented layer in both eyes. These changes were clinically compatible with the lack of iris transillumination defects. Additionally, iris bowing with a resultant narrowing of the angle occurred. The asymptomatic daughter showed discrete, but less severe iris stromal changes. CONCLUSION: This is the first detailed study of high frequency ultrasonic imaging of the iris in iridoschisis. The observed structural changes suggest angle narrowing by forward bowing of the anterior iris stroma may be a mechanism of IOP elevation in this condition. The ultrasonic detection of iris changes in the asymptomatic daughter of the symptomatic patient and the association of iridoschisis with fibrous dysplasia suggest a possible genetic component in the pathogenesis of this condition. Images PMID:9059271

  16. Iris: Constructing and Analyzing Spectral Energy Distributions with the Virtual Observatory

    NASA Astrophysics Data System (ADS)

    Laurino, O.; Budynkiewicz, J.; Busko, I.; Cresitello-Dittmar, M.; D'Abrusco, R.; Doe, S.; Evans, J.; Pevunova, O.

    2014-05-01

    We present Iris 2.0, the latest release of the Virtual Astronomical Observatory application for building and analyzing Spectral Energy Distributions (SEDs). With Iris, users may read in and display SEDs inspect and edit any selection of SED data, fit models to SEDs in arbitrary spectral ranges, and calculate confidence limits on best-fit parameters. SED data may be loaded into the application from VOTable and FITS files compliant with the International Virtual Observatoy Alliance interoperable data models, or retrieved directly from NED or the Italian Space Agency Science Data Center; data in non-standard formats may also be converted within the application. Users may seamlessy exchange data between Iris and other Virtual Observatoy tools using the Simple Application Messaging Protocol. Iris 2.0 also provides a tool for redshifting, interpolating, and measuring integratd fluxes, and allows simple aperture corrections for individual points and SED segments. Custom Python functions, template models and template libraries may be imported into Iris for fitting SEDs. Iris may be extended through Java plugins; users can install third-party packages, or develop their own plugin using Iris' Software Development Kit. Iris 2.0 is available for Linux and Mac OS X systems.

  17. Eclipse-Free-Time Assessment Tool for IRIS

    NASA Technical Reports Server (NTRS)

    Eagle, David

    2012-01-01

    IRIS_EFT is a scientific simulation that can be used to perform an Eclipse-Free- Time (EFT) assessment of IRIS (Infrared Imaging Surveyor) mission orbits. EFT is defined to be those time intervals longer than one day during which the IRIS spacecraft is not in the Earth s shadow. Program IRIS_EFT implements a special perturbation of orbital motion to numerically integrate Cowell's form of the system of differential equations. Shadow conditions are predicted by embedding this integrator within Brent s method for finding the root of a nonlinear equation. The IRIS_EFT software models the effects of the following types of orbit perturbations on the long-term evolution and shadow characteristics of IRIS mission orbits. (1) Non-spherical Earth gravity, (2) Atmospheric drag, (3) Point-mass gravity of the Sun, and (4) Point-mass gravity of the Moon. The objective of this effort was to create an in-house computer program that would perform eclipse-free-time analysis. of candidate IRIS spacecraft mission orbits in an accurate and timely fashion. The software is a suite of Fortran subroutines and data files organized as a "computational" engine that is used to accurately predict the long-term orbit evolution of IRIS mission orbits while searching for Earth shadow conditions.

  18. Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

    DTIC Science & Technology

    1999-01-01

    roa.es C. Tomis RedIRIS, Centro Comunicaciones CSIC RedIRIS Serrano 142, 28006 Madrid, Spain tel + 34-91-585-5150 fax +34-91-564-7421 e-mail...I&D) and managed by the Centro de Comunicaciones CSIC RedIRIS, which depends on the Scientific Research Council (Consejo Superior de Investigaciones

  19. Cross-sensor iris recognition through kernel learning.

    PubMed

    Pillai, Jaishanker K; Puertas, Maria; Chellappa, Rama

    2014-01-01

    Due to the increasing popularity of iris biometrics, new sensors are being developed for acquiring iris images and existing ones are being continuously upgraded. Re-enrolling users every time a new sensor is deployed is expensive and time-consuming, especially in applications with a large number of enrolled users. However, recent studies show that cross-sensor matching, where the test samples are verified using data enrolled with a different sensor, often lead to reduced performance. In this paper, we propose a machine learning technique to mitigate the cross-sensor performance degradation by adapting the iris samples from one sensor to another. We first present a novel optimization framework for learning transformations on iris biometrics. We then utilize this framework for sensor adaptation, by reducing the distance between samples of the same class, and increasing it between samples of different classes, irrespective of the sensors acquiring them. Extensive evaluations on iris data from multiple sensors demonstrate that the proposed method leads to improvement in cross-sensor recognition accuracy. Furthermore, since the proposed technique requires minimal changes to the iris recognition pipeline, it can easily be incorporated into existing iris recognition systems.

  20. Iris recognition based on robust principal component analysis

    NASA Astrophysics Data System (ADS)

    Karn, Pradeep; He, Xiao Hai; Yang, Shuai; Wu, Xiao Hong

    2014-11-01

    Iris images acquired under different conditions often suffer from blur, occlusion due to eyelids and eyelashes, specular reflection, and other artifacts. Existing iris recognition systems do not perform well on these types of images. To overcome these problems, we propose an iris recognition method based on robust principal component analysis. The proposed method decomposes all training images into a low-rank matrix and a sparse error matrix, where the low-rank matrix is used for feature extraction. The sparsity concentration index approach is then applied to validate the recognition result. Experimental results using CASIA V4 and IIT Delhi V1iris image databases showed that the proposed method achieved competitive performances in both recognition accuracy and computational efficiency.

  1. Comparison with IRI-PLUS and IRI-2012-TEC values of GPS-TEC values

    NASA Astrophysics Data System (ADS)

    Atıcı, Ramazan; Saǧır, Selçuk

    2016-07-01

    This study presents a comparison with IRI-PLUS and IRI-2012 Total Electron Content (TEC) values of Total Electron Content (TEC) values obtained from Ankara station (39,7 N; 32,76 E) of Global Position System (GPS) of Turkey on equinox and solstice days of 2009 year. For all days, it is observed that GPS-TEC values are greater than IRI-2012-TEC values, while IRI-PLUS-TEC values are very close to GPS-TEC values. When GPS-TEC values for both equinoxes are compared, it is seen that TEC values on September equinox are greater than one on March equinox. However, it is observed that GPS-TEC values on June solstice are greater than one on December solstice. Also, the relationship between GPS-TEC values and geomagnetic indexes is investigated.

  2. Suicidal tendency in a sample of adolescent outpatients with adjustment disorder: gender differences.

    PubMed

    Ferrer, Laia; Kirchner, Teresa

    2014-08-01

    Although Adjustment Disorder (AD) is a prevalent diagnosis in adolescent mental health services and linked to suicidal tendency in adolescence, little research exists examining prevalence and gender differences of suicidal symptoms among AD patients using standardized instruments. The present study aims to assess the presence of suicidal tendency in a clinical sample of Spanish adolescents with AD analyzing gender differences. Ninety-seven adolescents with AD were recruited at a public mental health center and included in the AD sample; they were administered the Inventario de Riesgo Suicida para Adolescentes (Suicide Risk Inventory for Adolescents-IRIS) and the Millon Adolescent Clinical Inventory (MACI). Ninety-nine community adolescents were recruited and administered the IRIS inventory. The community sample works as a contrast group. Girls with AD show higher levels of suicidal symptoms than boys on both the IRIS Suicidal Ideation and Intention scale (t=8.15, p<.001) and the MACI Suicidal Tendency scale (t=6.6, p<.001). Girls with AD scored significantly higher than girls from the community contrast group sample in the IRIS Suicidal Ideation and Intention scale, but boys with AD presented no differences with regard to boys form the community contrast group sample. Compared with normative clinical samples of the MACI, no differences in the Suicidal Tendency scale scores were found between AD and normative girls, but AD boys showed significantly lower mean scores than normative boys. Suicidal symptoms were presented by 27% of girls and 18% of boys, although only 6% of the girls and none of the boys presented clear suicidal tendencies. Considering suicidal tendencies in adolescents with Adjustment Disorder is important-especially in girls, who present high suicidal tendencies in relation both to boys and to community peers and the normative clinical population. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Standardised alcohol screening in primary health care services targeting Aboriginal and Torres Strait Islander peoples in Australia.

    PubMed

    Islam, M Mofizul; Oni, Helen T; Lee, K S Kylie; Hayman, Noel; Wilson, Scott; Harrison, Kristie; Hummerston, Beth; Ivers, Rowena; Conigrave, Katherine M

    2018-03-29

    Aboriginal and Torres Strait Islander Community Controlled Health Services (ACCHSs) around Australia have been asked to standardise screening for unhealthy drinking. Accordingly, screening with the 3-item AUDIT-C (Alcohol Use Disorders Identification Test-Consumption) tool has become a national key performance indicator. Here we provide an overview of suitability of AUDIT-C and other brief alcohol screening tools for use in ACCHSs. All peer-reviewed literature providing original data on validity, acceptability or feasibility of alcohol screening tools among Indigenous Australians was reviewed. Narrative synthesis was used to identify themes and integrate results. Three screening tools-full AUDIT, AUDIT-3 (third question of AUDIT) and CAGE (Cut-down, Annoyed, Guilty and Eye-opener) have been validated against other consumption measures, and found to correspond well. Short forms of AUDIT have also been found to compare well with full AUDIT, and were preferred by primary care staff. Help was often required with converting consumption into standard drinks. Researchers commented that AUDIT and its short forms prompted reflection on drinking. Another tool, the Indigenous Risk Impact Screen (IRIS), jointly screens for alcohol, drug and mental health risk, but is relatively long (13 items). IRIS has been validated against dependence scales. AUDIT, IRIS and CAGE have a greater focus on dependence than on hazardous or harmful consumption. Detection of unhealthy drinking before harms occur is a goal of screening, so AUDIT-C offers advantages over tools like IRIS or CAGE which focus on dependence. AUDIT-C's brevity suits integration with general health screening. Further research is needed on facilitating implementation of systematic alcohol screening into Indigenous primary healthcare.

  4. The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR): A High Speed, Multispectral, Thermal Instrument Development in Support of HyspIRI-TIR

    NASA Technical Reports Server (NTRS)

    Hook, Simon

    2011-01-01

    The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). The HyspIRI mission was recommended by the National Research Council Decadal Survey and includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. The HyspIRI TIR system will have 60m ground resolution, better than 200mK noise equivalent delta temperature (NEDT), 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. PHyTIR addresses the technology readiness level (TRL) of certain key subsystems of the TIR imager, primarily the detector assembly and scanning mechanism. PHyTIR will use Mercury Cadmium Telluride (MCT) technology at the focal plane and operate in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence allowing the high data rates needed for the 5 day repeat. PHyTIR will also demonstrate a newly developed interferometeric metrology system. This system will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  5. Tuberculosis immune reconstitution inflammatory syndrome in A5221 STRIDE: timing, severity, and implications for HIV-TB programs.

    PubMed

    Luetkemeyer, Anne F; Kendall, Michelle A; Nyirenda, Mulinda; Wu, Xingye; Ive, Prudence; Benson, Constance A; Andersen, Janet W; Swindells, Susan; Sanne, Ian M; Havlir, Diane V; Kumwenda, Johnstone

    2014-04-01

    Earlier initiation of antiretroviral therapy (ART) in HIV-tuberculosis (TB) is associated with increased immune reconstitution inflammatory syndrome (IRIS). The severity, frequency, and complications of TB IRIS were evaluated in A5221, a randomized trial of earlier ART (within 2 weeks after TB treatment initiation) vs. later ART (8-12 weeks after TB treatment) in HIV-infected patients starting TB treatment. In 806 participants, TB IRIS was defined using published clinical criteria. Cases were classified as severe (hospitalization/death), moderate (corticosteroid use/invasive procedure), or mild (no hospitalization/procedures/steroids). Fisher exact, Wilcoxon, and log-rank tests were used for comparisons. TB IRIS occurred in 61 (7.6%) patients: 10.4% in earlier vs. 4.7% in later ART, 11.5% with CD4 <50 vs. 5.4% with CD4 ≥50 cells per cubic millimeter. The CD4/ART arm interaction was significant, P = 0.014, with 44.3% of TB IRIS occurring with CD4 <50 and earlier ART. TB IRIS occurred sooner with earlier vs. later ART initiation, at a median of 29 vs. 82 days after TB treatment initiation (P < 0.001). IRIS manifestations included lymphadenopathy (59.0%), constitutional symptoms (54.1%), and radiographic changes (41.0%); central nervous system TB IRIS was uncommon (6.6%). TB IRIS was mild in 27.9%, moderate in 41.0%, and severe in 31.1%. No TB IRIS-associated deaths occurred. IRIS management required ≥1 invasive procedures in 34.4%, hospitalization in 31.1%, and corticosteroids in 54.1%. TB IRIS was more frequent with earlier ART initiation and CD4 <50 cells per cubic millimeter. As ART is implemented earlier in HIV-TB coinfection, programs will require the diagnostic capabilities, clinical resources, and training necessary to manage TB IRIS.

  6. Incidence and Predictors of Immune Reconstitution Inflammatory Syndrome in a Rural Area of Mozambique

    PubMed Central

    Letang, Emilio; Miró, José M.; Nhampossa, Tacilta; Ayala, Edgar; Gascon, Joaquim; Menéndez, Clara; Alonso, Pedro L.; Naniche, Denise

    2011-01-01

    Background There is limited data on the epidemiology of Immune Reconstitution Inflammatory Syndrome (IRIS) in rural sub-Saharan Africa. A prospective observational cohort study was conducted to assess the incidence, clinical characteristics, outcome and predictors of IRIS in rural Mozambique. Methods One hundred and thirty-six consecutive antiretroviral treatment (ART)-naïve HIV-1-infected patients initiating ART at the Manhiça district hospital were prospectively followed for development of IRIS over 16 months. Survival analysis by Cox regression was performed to identify pre-ART predictors of IRIS development. Results Thirty-six patients developed IRIS [26.5%, incidence rate 3.1 cases/100 persons-month of ART (95% CI 2.2–4.3)]. Median time to IRIS onset was 62 days from ART initiation (IQR 35.5–93.5). Twenty-five cases (69.4%) were “unmasking”, 10 (27.8%) were “paradoxical”, and 1 (2.8%) developed a paradoxical worsening followed by the unmasking of another condition. Systemic OI (OI-IRIS) accounted for 47% (17/36) of IRIS cases, predominantly of KS (8 cases) and TB (6 cases) IRIS. Mucocutaneous IRIS manifestations (MC-IRIS) accounted for 53% (19/36) of IRIS events, mostly tinea (9 cases) and herpes simplex infection (3 cases). Multivariate analysis identified two independent predictors of IRIS development: pre-ART CD4 count <50 cells/µl (HR 2.3, 95% CI 1.19–4.44, p = 0.01) and body mass index (BMI) <18.5 (HR 2.15, 95% CI 1.07–4.3, p = 0.03). The pre-cART proportion of activated T-cells, as well as the immunologic and virologic response to ART were not associated with IRIS development. All patients continued on ART, 7 (19.4%) required hospitalization and there were 3 deaths (8.3%) attributable to IRIS. Conclusions IRIS is common in patients initiating ART in rural Mozambique. Pre-ART CD4 counts and BMI can easily be assessed at ART initiation in rural sub-Saharan Africa to identify patients at high risk of IRIS, for whom close supervision is warranted. PMID:21386993

  7. Assessment of the potential noncancer health hazards of PCBs for inclusion on EPA’s Integrated Risk Information System (IRIS)

    EPA Science Inventory

    At present, there are IRIS RfDs for two commercial PCB mixtures: Aroclor 1016 and Aroclor 1254. There is no IRIS RfD for complex PCB mixtures in general; and the RfDs for Aroclor 1016 and Aroclor 1254 were last updated in 1993 and 1994, respectively. The new assessment will integ...

  8. IRIS Connect: Developing Classroom Dialogue and Formative Feedback through Collective Video Reflection. Evaluation Report and Executive Summary

    ERIC Educational Resources Information Center

    Davies, Peter; Perry, Tom; Kirkman, John

    2017-01-01

    IRIS is designed to improve primary school teachers' use of dialogue and feedback through using video technology for collaborative teacher development with a view to improving academic outcomes for pupils. It is based around a video technology system (IRIS Connect) which enables teachers to record, edit, and comment on teaching and learning. In…

  9. Three-dimensional Hessian matrix-based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy in vivo

    NASA Astrophysics Data System (ADS)

    Zhao, Huangxuan; Wang, Guangsong; Lin, Riqiang; Gong, Xiaojing; Song, Liang; Li, Tan; Wang, Wenjia; Zhang, Kunya; Qian, Xiuqing; Zhang, Haixia; Li, Lin; Liu, Zhicheng; Liu, Chengbo

    2018-04-01

    For the diagnosis and evaluation of ophthalmic diseases, imaging and quantitative characterization of vasculature in the iris are very important. The recently developed photoacoustic imaging, which is ultrasensitive in imaging endogenous hemoglobin molecules, provides a highly efficient label-free method for imaging blood vasculature in the iris. However, the development of advanced vascular quantification algorithms is still needed to enable accurate characterization of the underlying vasculature. We have developed a vascular information quantification algorithm by adopting a three-dimensional (3-D) Hessian matrix and applied for processing iris vasculature images obtained with a custom-built optical-resolution photoacoustic imaging system (OR-PAM). For the first time, we demonstrate in vivo 3-D vascular structures of a rat iris with a the label-free imaging method and also accurately extract quantitative vascular information, such as vessel diameter, vascular density, and vascular tortuosity. Our results indicate that the developed algorithm is capable of quantifying the vasculature in the 3-D photoacoustic images of the iris in-vivo, thus enhancing the diagnostic capability of the OR-PAM system for vascular-related ophthalmic diseases in vivo.

  10. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors

    PubMed Central

    Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David

    2016-01-01

    Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, p<0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors including iris melanocytic lesions for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. PMID:27856029

  11. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors.

    PubMed

    Skalet, Alison H; Li, Yan; Lu, Chen D; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G; Thomas, Charles R; Huang, David

    2017-02-01

    To evaluate tumor vasculature with optical coherence tomography angiography (OCTA) in malignant iris melanomas and benign iris lesions. Cross-sectional observational clinical study. Patients with iris lesions and healthy volunteers. Eyes were imaged using OCTA systems operating at 1050- and 840-nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanoma patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. OCT and OCTA images, qualitative evaluation of iris and tumor vasculature, and quantitative vessel density. One eye each of 8 normal volunteers and 9 patients with iris melanomas or benign iris lesions, including freckles, nevi, and an iris pigment epithelial (IPE) cyst, were imaged. The normal iris has radially oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In 2 eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, P < 0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050-nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% of participants in whom imaging was attempted. This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors, including iris melanocytic lesions, for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. IRIS Toxicological Review of Chloroprene (Peer Review Plan) ...

    EPA Pesticide Factsheets

    Chloroprene (C4H5Cl; 2-chloro-1,3-butadiene, CASRN 126-99-8) is a volatile, flammable liquid monomer used exclusively in the manufacture of neoprene (polychloroprene) elastomer which is used to make diverse products such as belts, hoses, gloves, wire coatings, and tubing. Chloroprene has a high vapor pressure, readily evaporates from water and solid surfaces, and readily oxidizes and form dimers and other oxygenated species in the absence of stabilizers (e.g., phenothiazine). When released to soil it may leach into groundwater, but breakdown via hydrolysis is not likely. Absorption into the body is possible through the lungs, gastrointestinal tract, or skin, and widespread distribution is evidenced by many target sites exhibiting effects. EPA has not developed an assessment of the potential for human health effects from exposure to chloroprene. Initial stages of development for this assessment are underway. The assessment is likely to include an oral reference value (RfD), an inhalation reference value (RfC), and a carcinogenicity assessment. Chloroprene will be entered into IRIS. IRIS is the Agency-approved source of toxicological and risk information accessible to the public, EPA regional offices, state governments and EPA regulatory program offices. This evaluation supports the Office of Air Quality Planning and Standards-Office of Air and Radiation in assessing the hazardous effects of chemicals that are listed as the greatest threat to the public

  13. Let the IRIS Bloom:Regrowing the integrated risk information system (IRIS) of the U.S. Environmental Protection Agency.

    PubMed

    Dourson, Michael L

    2018-05-03

    The Integrated Risk Information System (IRIS) of the U.S. Environmental Protection Agency (EPA) has an important role in protecting public health. Originally it provided a single database listing official risk values equally valid for all Agency offices, and was an important tool for risk assessment communication across EPA. Started in 1986, IRIS achieved full standing in 1990 when it listed 500 risk values, the effort of two senior EPA groups over 5 years of monthly face-to-face meetings, to assess combined risk data from multiple Agency offices. Those groups were disbanded in 1995, and the lack of continuing face-to-face meetings meant that IRIS became no longer EPA's comprehensive database of risk values or their latest evaluations. As a remedy, a work group of the Agency's senior scientists should be re-established to evaluate new risks and to update older ones. Risk values to be reviewed would come from the same EPA offices now developing such information on their own. Still, this senior group would have the final authority on posting a risk value in IRIS, independently of individual EPA offices. This approach could also lay the groundwork for an all-government IRIS database, especially needed as more government Agencies, industries and non-governmental organizations are addressing evolving risk characterizations. Copyright © 2018. Published by Elsevier Inc.

  14. EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and ...

    EPA Pesticide Factsheets

    EPA is releasing the draft report, EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (Volume 1), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The objective of this report is to respond to the NAS coments on dose-response modeling conducted in the EPA Reassessment of the health effects associated with dioxin exposure.

  15. Systematic Review: Concept and Tool Development with Application in the Integrated Risk Information System (IRIS) Assessment Process

    EPA Science Inventory

    Systematic Review: Concept and tool development with application to the National Toxicology Program (NTP) and the Integrated Risk Information System (IRIS) Assessment Processes. There is growing interest within the environmental health community to incorporate systematic review m...

  16. DSSTox EPA Integrated Risk Information System Structure-Index Locator File: SDF File and Documentation

    EPA Science Inventory

    EPA's Integrated Risk Information System (IRIS) database was developed and is maintained by EPA's Office of Research and Developement, National Center for Environmental Assessment. IRIS is a database of human health effects that may result from exposure to various substances fou...

  17. Pasdaran Incorporated: Evolving from Revolutionary to Praetorian Guard

    DTIC Science & Technology

    2010-03-01

    IRGN - Islamic Revolutionary Guards Corps’ Navy IRGQF - Islamic Revolutionary Guards Corps’ Qods Force IRI - Islamic Republic of Iran IRIAF - Islamic...1 I. INTRODUCTION A. PURPOSE The Islamic Revolutionary Guards Corps1 (IRGC) of the Islamic Republic of Iran ( IRI ) is a unique establishment that...civil–military relations. Until recently, conventional wisdom saw the IRGC as just a paramilitary element of the IRI national-security system. It

  18. Evaluation of the Carcinogenicity of Ethylene Oxide (2006 ...

    EPA Pesticide Factsheets

    EPA conducted a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of ethylene oxide (cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database. EPA is announcing a 30-day public comment period for this document. The release of this draft document is solely for the purpose of seeking public comment and for review by the EPA Science Advisory Board (SAB) via a meeting to be held later in 2006. The time and place of the SAB meeting will be announced in a separate Federal Register notice. This document has not been formally disseminated by EPA and does not represent, and should not be construed to represent, any Agency policy or determination. EPA will consider any public comments submitted in accordance with the requirements specified in the Notice of Public Comment Period when revising this draft document.

  19. CHARACTERIZATION OF DATA VARIABILITY AND UNCERTAINTY: HEALTH EFFECTS ASSESSMENTS IN THE INTEGRATED RISK INFORMATION SYSTEM (IRIS)

    EPA Science Inventory

    In response to a Congressional directive contained in HR 106-379 regarding EPA's appropriations for FY2000, EPA has undertaken an evaluation of the characterization of data variability and uncertainty in its Integrated Risk Information System (IRIS) health effects information dat...

  20. Silicon Graphics' IRIS InSight: An SGML Success Story.

    ERIC Educational Resources Information Center

    Glushko, Robert J.; Kershner, Ken

    1993-01-01

    Offers a case history of the development of the Silicon Graphics "IRIS InSight" system, a system for viewing on-line documentation using Standard Generalized Markup Language. Notes that SGML's explicit encoding of structure and separation of structure and presentation make possible structure-based search, alternative structural views of…

  1. Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study

    PubMed Central

    Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.

    2010-01-01

    Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039

  2. The concave iris in pigment dispersion syndrome.

    PubMed

    Liu, Lance; Ong, Ee Lin; Crowston, Jonathan

    2011-01-01

    To visualize the changes of the iris contour in patients with pigment dispersion syndrome after blinking, accommodation, and pharmacologic miosis using anterior segment optical coherence tomography. Observational case series. A total of 33 eyes of 20 patients with pigment dispersion syndrome. Each eye was imaged along the horizontal 0- to 180-degree meridian using the Visante Anterior Segment Imaging System (Carl Zeiss Meditec, Dublin, CA). Scans were performed at baseline and after focusing on an internal fixation target for 5 minutes, forced blinking, accommodation, and pharmacologic miosis with pilocarpine 2%. Quantitative analysis of the changes in the iris configuration. After 5 minutes of continual fixation, the iris became planar with the mean ± standard deviation curvature decreasing from 214 ± 74 μm to 67 ± 76 μm (P < 0.05). The iris remained planar in all patients with pigment dispersion syndrome after forced blinking, but the iris concavity recovered to 227 ± 113 μm (P = 0.34) and 238 ± 119 μm (P = 0.19) with the -3.0 and -6.0 diopter lenses, respectively. Pilocarpine-induced miosis caused the iris to assume a planar configuration in all subjects. This study shows that the iris in pigment dispersion syndrome assumes a planar configuration when fixating and that the concavity of the iris surface is not restored by blinking. Accommodation restored the iris concavity, suggesting that the posterior curvature of the iris in pigment dispersion syndrome is induced and probably maintained, at least in part, by accommodation. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. IRIS Toxicological Review of Trimethylbenzenes (Final Report ...

    EPA Pesticide Factsheets

    EPA has finalized the Integrated Risk Information System (IRIS) Assessment of Trimethylbenzenes (TMBs). This assessment addresses the potential non-cancer and cancer human health effects from long-term exposure to TMBs. Now final, this assessment will be the first IRIS assessment for TMBs that may be used by EPA’s program and regional offices to inform decisions to protect human health. The IRIS Toxicological Review of Trimethylbenzenes was originally released for a 60-day public comment period on June 29, 2012. EPA revised the toxicological review in response to the public comments received and released the finalized TMB assessment.

  4. Biometric iris image acquisition system with wavefront coding technology

    NASA Astrophysics Data System (ADS)

    Hsieh, Sheng-Hsun; Yang, Hsi-Wen; Huang, Shao-Hung; Li, Yung-Hui; Tien, Chung-Hao

    2013-09-01

    Biometric signatures for identity recognition have been practiced for centuries. Basically, the personal attributes used for a biometric identification system can be classified into two areas: one is based on physiological attributes, such as DNA, facial features, retinal vasculature, fingerprint, hand geometry, iris texture and so on; the other scenario is dependent on the individual behavioral attributes, such as signature, keystroke, voice and gait style. Among these features, iris recognition is one of the most attractive approaches due to its nature of randomness, texture stability over a life time, high entropy density and non-invasive acquisition. While the performance of iris recognition on high quality image is well investigated, not too many studies addressed that how iris recognition performs subject to non-ideal image data, especially when the data is acquired in challenging conditions, such as long working distance, dynamical movement of subjects, uncontrolled illumination conditions and so on. There are three main contributions in this paper. Firstly, the optical system parameters, such as magnification and field of view, was optimally designed through the first-order optics. Secondly, the irradiance constraints was derived by optical conservation theorem. Through the relationship between the subject and the detector, we could estimate the limitation of working distance when the camera lens and CCD sensor were known. The working distance is set to 3m in our system with pupil diameter 86mm and CCD irradiance 0.3mW/cm2. Finally, We employed a hybrid scheme combining eye tracking with pan and tilt system, wavefront coding technology, filter optimization and post signal recognition to implement a robust iris recognition system in dynamic operation. The blurred image was restored to ensure recognition accuracy over 3m working distance with 400mm focal length and aperture F/6.3 optics. The simulation result as well as experiment validates the proposed code apertured imaging system, where the imaging volume was 2.57 times extended over the traditional optics, while keeping sufficient recognition accuracy.

  5. [Coding Causes of Death with IRIS Software. Impact in Navarre Mortality Statistic].

    PubMed

    Floristán Floristán, Yugo; Delfrade Osinaga, Josu; Carrillo Prieto, Jesus; Aguirre Perez, Jesus; Moreno-Iribas, Conchi

    2016-08-02

    There are few studies that analyze changes in mortality statistics derived from the use of IRIS software, an automatic system for coding multiple causes of death and for the selection of the underlying cause of death, compared to manual coding. This study evaluated the impact of the use of IRIS in the Navarre mortality statistic. We proceeded to double coding 5,060 death certificates corresponding to residents in Navarra in 2014. We calculated coincidence between the two encodings for ICD10 chapters and for the list of causes of the Spanish National Statistics Institute (INE-102) and we estimated the change on mortality rates. IRIS automatically coded 90% of death certificates. The coincidence to 4 characters and in the same chapter of the CIE10 was 79.1% and 92.0%, respectively. Furthermore, coincidence with the short INE-102 list was 88.3%. Higher matches were found in death certificate of people under 65 years. In comparison with manual coding there was an increase in deaths from endocrine diseases (31%), mental disorders (19%) and disease of nervous system (9%), while a decrease of genitourinary system diseases was observed (21%). The coincidence at level of ICD10 chapters coding by IRIS in comparison to manual coding was 9 out of 10 deaths, similar to what is observed in other studies. The implementation of IRIS has led to increased of endocrine diseases, especially diabetes and hyperlipidaemia, and mental disorders, especially dementias.

  6. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies.

    PubMed

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST's measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform.

  7. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies

    PubMed Central

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST’s measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform. PMID:26401431

  8. IRIS Toxicological Review of Vinyl Chloride (Final Report ...

    EPA Pesticide Factsheets

    EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database. Common synonyms of vinyl chloride (VC) include chloroethene, chloroethylene, ethylene monochloride, and monochloroethene. VC is a synthetic chemical used as a chemical intermediate in the polymerization of polyvinyl chloride.

  9. Hyperspectral imaging of the human iris

    NASA Astrophysics Data System (ADS)

    Di Cecilia, Luca; Marazzi, Francesco; Rovati, Luigi

    2017-07-01

    We describe an optical system and a method for measuring the human iris spectral reflectance in vivo by hyperspectral imaging analysis. It is important to monitor age-related changes in the reflectance properties of the iris as they are a prognostic factor for several eye pathologies. In this paper, we report the outcomes of our most recent research, resulting from the improvement of our imaging system. In particular, a custom tunable light source was developed: the images are now acquired in the spectral range 440 - 900 nm. With this system, we are able to obtain a spectral resolution of 20nm, while each image of 2048 x 1536 pixels has a spatial resolution of 10.7 μm. The results suggest that the instrument could be exploited for measuring iris pigmentation changes over time. These measurements could provide new diagnostic capabilities in ophthalmology. Further studies are required to determine the measurements' repeatability and to develop a spectral library for results evaluation and to detect differences among subsequent screenings of the same subject.

  10. 75 FR 50761 - Draft Toxicological Review of Dichloromethane: In Support of Summary Information on the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-17

    ... Toxicological Review of Dichloromethane: In Support of Summary Information on the Integrated Risk Information... Summary Information on the Integrated Risk Information System (IRIS)'' (EPA/635/R-10/003A). The draft... Support of Summary Information on the Integrated Risk Information System (IRIS)'' is available primarily...

  11. 75 FR 69065 - Draft Toxicological Review of Urea: In Support of Summary Information on the Integrated Risk...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-10

    ... Summary Information on the Integrated Risk Information System (IRIS) AGENCY: Environmental Protection..., ``Toxicological Review of Urea: In Support of Summary Information on the Integrated Risk Information System (IRIS...: The draft ``Toxicological Review of Urea: In Support of Summary Information on the Integrated Risk...

  12. 76 FR 54228 - Draft Toxicological Review of Acrylonitrile: In Support of Summary Information on the Integrated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... Toxicological Review of Acrylonitrile: In Support of Summary Information on the Integrated Risk Information... Acrylonitrile: In Support of Summary Information on the Integrated Risk Information System (IRIS)'' (EPA/635/R... Acrylonitrile: In Support of Summary Information on the Integrated Risk Information System (IRIS)'' is available...

  13. Cyromazine

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment 1 Cyromazine ; CASRN 66215 - 27 - 8Human health assessment information on a chemical substance is included in the IRIS database only after a comp

  14. The infrared imaging spectrograph (IRIS) for TMT: overview of innovative science programs

    NASA Astrophysics Data System (ADS)

    Wright, Shelley A.; Larkin, James E.; Moore, Anna M.; Do, Tuan; Simard, Luc; Adamkovics, Maté; Armus, Lee; Barth, Aaron J.; Barton, Elizabeth; Boyce, Hope; Cooke, Jeffrey; Cote, Patrick; Davidge, Timothy; Ellerbroek, Brent; Ghez, Andrea M.; Liu, Michael C.; Lu, Jessica R.; Macintosh, Bruce A.; Mao, Shude; Marois, Christian; Schoeck, Matthias; Suzuki, Ryuji; Tan, Jonathan C.; Treu, Tommaso; Wang, Lianqi; Weiss, Jason

    2014-07-01

    IRIS (InfraRed Imaging Spectrograph) is a first light near-infrared diffraction limited imager and integral field spectrograph being designed for the future Thirty Meter Telescope (TMT). IRIS is optimized to perform astronomical studies across a significant fraction of cosmic time, from our Solar System to distant newly formed galaxies (Barton et al. [1]). We present a selection of the innovative science cases that are unique to IRIS in the era of upcoming space and ground-based telescopes. We focus on integral field spectroscopy of directly imaged exoplanet atmospheres, probing fundamental physics in the Galactic Center, measuring 104 to 1010 M supermassive black hole masses, resolved spectroscopy of young star-forming galaxies (1 < z < 5) and first light galaxies (6 < z < 12), and resolved spectroscopy of strong gravitational lensed sources to measure dark matter substructure. For each of these science cases we use the IRIS simulator (Wright et al. [2], Do et al. [3]) to explore IRIS capabilities. To highlight the unique IRIS capabilities, we also update the point and resolved source sensitivities for the integral field spectrograph (IFS) in all five broadband filters (Z, Y, J, H, K) for the finest spatial scale of 0.004" per spaxel. We briefly discuss future development plans for the data reduction pipeline and quicklook software for the IRIS instrument suite.

  15. Shape Adaptive, Robust Iris Feature Extraction from Noisy Iris Images

    PubMed Central

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-01-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate. PMID:24696801

  16. Shape adaptive, robust iris feature extraction from noisy iris images.

    PubMed

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-10-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate.

  17. Comparative analysis of classification based algorithms for diabetes diagnosis using iris images.

    PubMed

    Samant, Piyush; Agarwal, Ravinder

    2018-01-01

    Photo-diagnosis is always an intriguing area for the researchers, with the advancement of image processing and computer machine vision techniques it have become more reliable and popular in recent years. The objective of this paper is to study the change in the features of iris, particularly irregularities in the pigmentation of certain areas of the iris with respect to diabetic health of an individual. Apart from the point that iris recognition concentrates on the overall structure of the iris, diagnostic techniques emphasises the local variations in the particular area of iris. Pre-image processing techniques have been applied to extract iris and thereafter, region of interest from the extracted iris have been cropped out. In order to observe the changes in the tissue pigmentation of region of interest, statistical, texture textural and wavelet features have been extracted. At the end, a comparison of accuracies of five different classifiers has been presented to classify two subject groups of diabetic and non-diabetic. Best classification accuracy has been calculated as 89.66% by the random forest classifier. Results have been shown the effectiveness and diagnostic significance of the proposed methodology. Presented piece of work offers a novel systemic perspective of non-invasive and automatic diabetic diagnosis.

  18. The IRIS Spool-Type Reactor Coolant Pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kujawski, J.M.; Kitch, D.M.; Conway, L.E.

    2002-07-01

    IRIS (International Reactor Innovative and Secure) is a light water cooled, 335 MWe power reactor which is being designed by an international consortium as part of the US DOE NERI Program. IRIS features an integral reactor vessel that contains all the major reactor coolant system components including the reactor core, the coolant pumps, the steam generators and the pressurizer. This integral design approach eliminates the large coolant loop piping, and thus eliminates large loss-of-coolant accidents (LOCAs) as well as the individual component pressure vessels and supports. In addition, IRIS is being designed with a long life core and enhanced safetymore » to address the requirements defined by the US DOE for Generation IV reactors. One of the innovative features of the IRIS design is the adoption of a reactor coolant pump (called 'spool' pump) which is completely contained inside the reactor vessel. Background, status and future developments of the IRIS spool pump are presented in this paper. (authors)« less

  19. Investigation of TEC Variations over Mid-Latitude during Quit and Disturbed Days of March 2015

    NASA Astrophysics Data System (ADS)

    Atıcı, Ramazan; Saǧır, Selçuk; Güzel, Esat

    2016-07-01

    The variations during 09-14-March-2015 quit days and 15-20 March 2015 disturbed days of Total Electron Content (TEC) values (provided by IONOLAB group) obtained by analysis the data from Ankara Global Position System (GPS) station of Turkey located at mid-latitude, IRI -2012 model the and IRI-PLUS model are investigated. Also, the variations of the geomagnetic, interplanetary and solar wind parameters are examined. As a result of investigations, TEC values from all three models are not change too much at quit days. Unlike, at the disturbed days, although IRI-2012 and IRI-PLUS TEC values are not change too much, a noticeable change in GPS-TEC values is occurred. GPS-TEC values are rapidly increased on 17-March 2015 to be severe magnetic storm (Dst = -124 nT). Then, on following days it was observed to significantly decrease. Thus, it is said that GPS-TEC values are more sensitive than IRI-2012 and IRI-PLUS models to variations occurred on disturbed days.

  20. Communications/Navigation Outage Forecasting System (C/NOFS)

    DTIC Science & Technology

    2010-02-21

    al., 2002]. They are also lower than values predicted by the International Reference Iono- sphere ( IRI ) model [Gulyaeva and Titheridge, 2006] run for...based on the IRI model or other observations. At present no mechanism has been proposed which accounts for the basic formation of BPDs or their...funding by the DMSP program office. We thank J. Retterer for the IRI model results. This research was supported by Air Force Office of Scientific Research

  1. Nitrobenzene

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 004F www.epa.gov / iris TOXICOLOGICAL REVIEW OF NITROBENZENE ( CAS No . 98 - 95 - 3 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) January 2009 U.S . Environmental Protection Agency Washington , DC i DISCLAIMER This documen

  2. Radium 226,228

    Integrated Risk Information System (IRIS)

    Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment Radium 226,228 ; CASRN 7440 - 14 - 4 , Human health assessment information on a chemical substance is included in the IRIS database only after a

  3. High sensitivity of Indian summer monsoon to Middle East dust absorptive properties.

    PubMed

    Jin, Qinjian; Yang, Zong-Liang; Wei, Jiangfeng

    2016-07-28

    The absorptive properties of dust aerosols largely determine the magnitude of their radiative impacts on the climate system. Currently, climate models use globally constant values of dust imaginary refractive index (IRI), a parameter describing the dust absorption efficiency of solar radiation, although it is highly variable. Here we show with model experiments that the dust-induced Indian summer monsoon (ISM) rainfall differences (with dust minus without dust) change from -9% to 23% of long-term climatology as the dust IRI is changed from zero to the highest values used in the current literature. A comparison of the model results with surface observations, satellite retrievals, and reanalysis data sets indicates that the dust IRI values used in most current climate models are too low, tending to significantly underestimate dust radiative impacts on the ISM system. This study highlights the necessity for developing a parameterization of dust IRI for climate studies.

  4. [Iris abscess after bacterial endocarditis in a patient with leukaemia. Differential diagnosis].

    PubMed

    Manrique Lipa, R; González Sánchez, E; Asencio Duran, M; Gonzalez-Peramato, P; Fonseca Santodomingo, A

    2014-04-01

    To report a case of iris abscess due to bacterial endocarditis. A 46-year-old male under diagnosis of promielocitic leukemia and endocarditis presented with decreased vision in left eye (OS). Ophthalmic exploration revealed iris abscess and hypopyon with fibrinous exudate in iris of the left eye and tyndall +1 in right eye (OD). Blood culture and anterior chamber paracentesis was positive for methicillin-sensitive Staphylococcus aureus and negative for blastic cells in citology. Treatment with systemic antibiotic was initiated with total resolution of inflammation. Iris abscess is an unusual septic focus in bacterial endocarditis. It is crucial to rule out an extramedullary metastasis in a patient with leukemia due to the general prognosis. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  5. Assessment of IRI-2012, NeQuick-2 and IRI-Plas 2015 models with observed equatorial ionization anomaly in Africa during 2009 sudden stratospheric warming event

    NASA Astrophysics Data System (ADS)

    Bolaji, O. S.; Oyeyemi, E. O.; Adewale, A. O.; Wu, Q.; Okoh, D.; Doherty, P. H.; Kaka, R. O.; Abbas, M.; Owolabi, C.; Jidele, P. A.

    2017-11-01

    In Africa, we assessed the performance of all the three options of International Reference Ionosphere 2012, IRI-2012 (i.e. IRI-2001, IRI-2001COR and IRI-NeQuick), NeQuick-2 and IRI-Plas 2015 models prior to and during 2009 sudden stratospheric warming (SSW) event to predict equatorial ionization anomaly (EIA) crest locations and their magnitudes using total electron content (TEC) from experimental records of Global Positioning System (GPS). We confirmed that the IRI-Plas 2015 that appeared as the best compared to all of the models as regard prediction of the EIA crest locations in the northern hemisphere of Africa is due to discontinuities in the GPS data between ∼8° N and 22° N. As regard the predictions of EIA crest magnitudes and the location of EIA crests in the southern hemisphere of Africa, they are not present in all the models. The NeQuick-2 model does not have the capability to predict either the EIA crest location in the northern or southern hemisphere. The SSW effect on the low latitude was able to modify a single EIA crest to pre-noon and post noon EIA crests in the northern hemisphere during the SSW peak phase and significantly reduced the GPS TEC magnitudes over the hemispheres as well. These SSW effects and delays of plasma transportation to higher latitudes in GPS TEC were absent in all the models. For future improvements of IRI-2012, NeQuick-2 and IRI-Plas 2015 models, SSW conditions should be included in order to characterize the effect of lower atmosphere on the ionosphere. The EIA trough modeling is only present in IRI-2001COR and IRI-2001NeQuick options. In the middle latitude, all the model could not predict the location of highest TEC magnitudes found at RBAY (Richardsbay, South Africa).

  6. Increasing the information acquisition volume in iris recognition systems.

    PubMed

    Barwick, D Shane

    2008-09-10

    A significant hurdle for the widespread adoption of iris recognition in security applications is that the typically small imaging volume for eye placement results in systems that are not user friendly. Separable cubic phase plates at the lens pupil have been shown to ameliorate this disadvantage by increasing the depth of field. However, these phase masks have limitations on how efficiently they can capture the information-bearing spatial frequencies in iris images. The performance gains in information acquisition that can be achieved by more general, nonseparable phase masks is demonstrated. A detailed design method is presented, and simulations using representative designs allow for performance comparisons.

  7. Pharmacology of Ischemia-Reperfusion. Translational Research Considerations.

    PubMed

    Prieto-Moure, Beatriz; Lloris-Carsí, José M; Barrios-Pitarque, Carlos; Toledo-Pereyra, Luis-H; Lajara-Romance, José María; Berda-Antolí, M; Lloris-Cejalvo, J M; Cejalvo-Lapeña, Dolores

    2016-08-01

    Ischemia-reperfusion (IRI) is a complex physiopathological mechanism involving a large number of metabolic processes that can eventually lead to cell apoptosis and ultimately tissue necrosis. Treatment approaches intended to reduce or palliate the effects of IRI are varied, and are aimed basically at: inhibiting cell apoptosis and the complement system in the inflammatory process deriving from IRI, modulating calcium levels, maintaining mitochondrial membrane integrity, reducing the oxidative effects of IRI and levels of inflammatory cytokines, or minimizing the action of macrophages, neutrophils, and other cell types. This study involved an extensive, up-to-date review of the bibliography on the currently most widely used active products in the treatment and prevention of IRI, and their mechanisms of action, in an aim to obtain an overview of current and potential future treatments for this pathological process. The importance of IRI is clearly reflected by the large number of studies published year after year, and by the variety of pathophysiological processes involved in this major vascular problem. A quick study of the evolution of IRI-related publications in PubMed shows that in a single month in 2014, 263 articles were published, compared to 806 articles in the entire 1990.

  8. Update On Ink Jet Proofing

    NASA Astrophysics Data System (ADS)

    Santos, Richard P.

    1989-04-01

    IRIS Graphics, Inc., is a new start-up company chartered to develop, manufacture, and market direct digital filmless color imaging systems. IRIS is pleased to have been the recipient of the Graphic Art Technologies Foundation INTERTEC '87 Award for innovative excellence. IRIS is extremely proud to have been given this honor. IRIS was incorporated in April 1984 and received its initial funding of approximately 1 million by September 1984. The first 2044 Beta unit was installed in August 1985, and the first 2044 sales were made in December 1985 to R. R. Donnelley, the largest printer in the United States, and to G. S. Litho, the largest U.S. color separation house. In May 1986, IRIS received an additional 3 million in its second round of financing. A smaller version of the 2044, the 2024 was introduced at Lasers In Graphics in September 1986. IRIS achieved additional financing in July 1987 and completed the introduction of the new breakthrough Series 3000 again at Lasers In Graphics in September 1987 in Orlando, Florida. IRIS occupies 20,000 square feet at its new location in Bedford, Massachusetts, which located off of Route 128 in the high technology area near Boston.

  9. Cyberinfrastructure at IRIS: Challenges and Solutions Providing Integrated Data Access to EarthScope and Other Earth Science Data

    NASA Astrophysics Data System (ADS)

    Ahern, T. K.; Barga, R.; Casey, R.; Kamb, L.; Parastatidis, S.; Stromme, S.; Weertman, B. T.

    2008-12-01

    While mature methods of accessing seismic data from the IRIS DMC have existed for decades, the demands for improved interdisciplinary data integration call for new approaches. Talented software teams at the IRIS DMC, UNAVCO and the ICDP in Germany, have been developing web services for all EarthScope data including data from USArray, PBO and SAFOD. These web services are based upon SOAP and WSDL. The EarthScope Data Portal was the first external system to access data holdings from the IRIS DMC using Web Services. EarthScope will also draw more heavily upon products to aid in cross-disciplinary data reuse. A Product Management System called SPADE allows archive of and access to heterogeneous data products, presented as XML documents, at the IRIS DMC. Searchable metadata are extracted from the XML and enable powerful searches for products from EarthScope and other data sources. IRIS is teaming with the External Research Group at Microsoft Research to leverage a powerful Scientific Workflow Engine (Trident) and interact with the web services developed at centers such as IRIS to enable access to data services as well as computational services. We believe that this approach will allow web- based control of workflows and the invocation of computational services that transform data. This capability will greatly improve access to data across scientific disciplines. This presentation will review some of the traditional access tools as well as many of the newer approaches that use web services, scientific workflow to improve interdisciplinary data access.

  10. IRIS Toxicological Review of Hexachloroethane (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Hexachloroethane: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  11. Methanol

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 11 / 001Fa www.epa.gov / iris TOXICOLOGICAL REVIEW OF METHANOL ( NONCANCER ) ( CAS No . 67 - 56 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2013 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER This document

  12. Hydrogen sulfide

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 03 / 005 www.epa.gov / iris TOXICOLOGICAL REVIEW OF HYDROGEN SULFIDE ( CAS No . 7783 - 06 - 4 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2003 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been

  13. Dichloromethane

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 10 / 003F ww.epa.gov / iris TOXICOLOGICAL REVIEW OF DICHLOROMETHANE ( METHYLENE CHLORIDE ) ( CAS No . 75 - 09 - 2 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) November 2011 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER T

  14. Chlordecone (Kepone)

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 07 / 004F www.epa.gov / iris TOXICOLOGICAL REVIEW OF CHLORDECONE ( KEPONE ) ( CAS No . 143 - 50 - 0 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2009 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has

  15. Ethylene oxide

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 16 / 350Fc www.epa.gov / iris Evaluation of the Inhalation Carcinogenicity of Ethylene Oxide EXECUTIVE SUMMARY ( CASRN 75 - 21 - 8 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) December 201 6 National Center for Environmental Assessment Office

  16. Cyclohexane

    Integrated Risk Information System (IRIS)

    EPA 635 / R - 03 / 008 www.epa.gov / iris TOXICOLOGICAL REVIEW OF CYCLOHEXANE ( CAS No . 110 - 82 - 7 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) August 2003 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been revie

  17. Chloroprene

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 09 / 010F www.epa.gov / iris TOXICOLOGICAL REVIEW OF CHLOROPRENE ( CAS No . 126 - 99 - 8 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2010 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been revie

  18. Propionaldehyde

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 003F www.epa.gov / iris TOXICOLOGICAL REVIEW OF PROPIONALDEHYDE ( CAS No . 123 - 38 - 6 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2008 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been r

  19. 2-Methylnaphthalene

    Integrated Risk Information System (IRIS)

    EPA 635 / R - 03 / 010 www.epa.gov / iris TOXICOLOGICAL REVIEW OF 2 - METHYLNAPHTHALENE ( CAS No . 91 - 57 - 6 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) December 2003 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been

  20. Hexachloroethane

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 09 / 007F www.epa.gov / iris TOXICOLOGICAL REVIEW OF HEXACHLOROETHANE ( CAS No . 67 - 72 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2011 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been r

  1. IRIS Toxicological Review of Urea (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Urea: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  2. IRIS Toxicological Review of Pentachlorophenol (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Pentachlorophenol: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  3. IRIS Toxicological Review of Biphenyl (Final Report)

    EPA Science Inventory

    EEPA has finalized the Toxicological Review of Biphenyl: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  4. RE: Request for Correction - SAB Workgroup Review of Draft IRIS Assessment for Inorganic Arsenic

    EPA Pesticide Factsheets

    Request from Lynn Bergeson for the correction of information in the draft EPA document Toxicological Review of Inorganic Arsenic: In Support of the Summary Information on the Integrated Risk Information System (IRIS).

  5. EXPOSURE SUMMARIES FOR IRIS CHEMICALS.

    EPA Science Inventory

    The Integrated Risk Information System (IRIS), prepared and maintained by the National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (U.S. EPA), is an electronic database containing information on human health effects that may result from ...

  6. Reliability of automatic biometric iris recognition after phacoemulsification or drug-induced pupil dilation.

    PubMed

    Seyeddain, Orang; Kraker, Hannes; Redlberger, Andreas; Dexl, Alois K; Grabner, Günther; Emesz, Martin

    2014-01-01

    To investigate the reliability of a biometric iris recognition system for personal authentication after cataract surgery or iatrogenic pupil dilation. This was a prospective, nonrandomized, single-center, cohort study for evaluating the performance of an iris recognition system 2-24 hours after phacoemulsification and intraocular lens implantation (group 1) and before and after iatrogenic pupil dilation (group 2). Of the 173 eyes that could be enrolled before cataract surgery, 164 (94.8%) were easily recognized postoperatively, whereas in 9 (5.2%) this was not possible. However, these 9 eyes could be reenrolled and afterwards recognized successfully. In group 2, of a total of 184 eyes that were enrolled in miosis, a total of 22 (11.9%) could not be recognized in mydriasis and therefore needed reenrollment. No single case of false-positive acceptance occurred in either group. The results of this trial indicate that standard cataract surgery seems not to be a limiting factor for iris recognition in the large majority of cases. Some patients (5.2% in this study) might need "reenrollment" after cataract surgery. Iris recognition was primarily successful in eyes with medically dilated pupils in nearly 9 out of 10 eyes. No single case of false-positive acceptance occurred in either group in this trial. It seems therefore that iris recognition is a valid biometric method in the majority of cases after cataract surgery or after pupil dilation.

  7. Assessment of Urbanization on the Integrated Land-Ocean-Atmosphere Environment in Coastal Metropolis in Preparation for HyspIRI

    NASA Technical Reports Server (NTRS)

    Sequera, Pedro; McDonald, Kyle C.; Gonzalez, Jorge; Arend, Mark; Krakauer, Nir; Bornstein, Robert; Luvll, Jeffrey

    2012-01-01

    The need for comprehensive studies of the relationships between past and projected changes of regional climate and human activity in comple x urban environments has been well established. The HyspIRI preparato ry airborne activities in California, associated science and applicat ions research, and eventually HyspIRI itself provide an unprecedented opportunity for development and implementation of an integrated data and modeling analysis system focused on coastal urban environments. We will utilize HyspIRI preparatory data collections in developing ne w remote sensing-based tools for investigating the integrated urban e nvironment, emphasizing weather, climate, and energy demands in compl ex coastal cities.

  8. IRIS Toxicological Review of Ammonia Noncancer Inhalation (Final Report)

    EPA Science Inventory

    EPA has finalized the Integrated Risk Information System (IRIS) Assessment of Ammonia (Noncancer Inhalation). This assessment addresses the potential noncancer human health effects from long-term inhalation exposure to ammonia. Now final, this assessment will update the ...

  9. Carbon tetrachloride

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 005F www.epa.gov / iris TOXICOLOGICAL REVIEW OF CARBON TETRACHLORIDE ( CAS No . 56 - 23 - 5 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) March 2010 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER This document has bee

  10. Trichloroacetic acid

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 09 / 003F www.epa.gov / iris TOXICOLOGICAL REVIEW OF TRICHLOROACETIC ACID ( CAS No . 76 - 03 - 9 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2011 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER This document has

  11. 1,4-Dioxane

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 11 / 003F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 1,4 - DIOXANE ( WITH INHALATION UPDATE ) ( CAS No . 123 - 91 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2013 U.S . Environmental Protection Agency Washington , DC DISCLAIMER

  12. IRIS Toxicological Review of Tetrahydrofuran (THF) (Final Report)

    EPA Science Inventory

    EPA has released the Toxicological Review of Tetrahydrofuran: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  13. IRIS Toxicological Review of Carbon Tetrachloride (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Carbon Tetrachloride: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  14. Iris recognition: on the segmentation of degraded images acquired in the visible wavelength.

    PubMed

    Proença, Hugo

    2010-08-01

    Iris recognition imaging constraints are receiving increasing attention. There are several proposals to develop systems that operate in the visible wavelength and in less constrained environments. These imaging conditions engender acquired noisy artifacts that lead to severely degraded images, making iris segmentation a major issue. Having observed that existing iris segmentation methods tend to fail in these challenging conditions, we present a segmentation method that can handle degraded images acquired in less constrained conditions. We offer the following contributions: 1) to consider the sclera the most easily distinguishable part of the eye in degraded images, 2) to propose a new type of feature that measures the proportion of sclera in each direction and is fundamental in segmenting the iris, and 3) to run the entire procedure in deterministically linear time in respect to the size of the image, making the procedure suitable for real-time applications.

  15. Privacy information management for video surveillance

    NASA Astrophysics Data System (ADS)

    Luo, Ying; Cheung, Sen-ching S.

    2013-05-01

    The widespread deployment of surveillance cameras has raised serious privacy concerns. Many privacy-enhancing schemes have been proposed to automatically redact images of trusted individuals in the surveillance video. To identify these individuals for protection, the most reliable approach is to use biometric signals such as iris patterns as they are immutable and highly discriminative. In this paper, we propose a privacy data management system to be used in a privacy-aware video surveillance system. The privacy status of a subject is anonymously determined based on her iris pattern. For a trusted subject, the surveillance video is redacted and the original imagery is considered to be the privacy information. Our proposed system allows a subject to access her privacy information via the same biometric signal for privacy status determination. Two secure protocols, one for privacy information encryption and the other for privacy information retrieval are proposed. Error control coding is used to cope with the variability in iris patterns and efficient implementation is achieved using surrogate data records. Experimental results on a public iris biometric database demonstrate the validity of our framework.

  16. Development of An Analytic Approach to Determine How Environmental Protection Agency’s Integrated Risk Information System (IRIS) Is Used by Non-EPA Decision Makers (Final Contractor Report)

    EPA Science Inventory

    EPA announced the availability of the final contractor report entitled, Development of an Analytic Approach to Determine How Environmental Protection Agency’s Integrated Risk Information System (IRIS) Is Used By Non EPA Decision Makers. This contractor report analyzed how ...

  17. IRIS Toxicological Review of Inorganic Arsenic (Cancer) ...

    EPA Pesticide Factsheets

    EPA's Science Advisory Board (SAB) conducted a review of the scientific basis supporting the human health cancer hazard and dose-response assessment of inorganic arsenic that will appear on the Integrated Risk Information System (IRIS) database. EPA revised the assessment and is now returning the assessment to the SAB and releasing the document to the public for a focused review of EPA's responses to the SAB recommendations. This draft IRIS health assessment addresses only cancer human health effects that may result from chronic exposure to this chemical.

  18. Physician acceptance of the IRIS user interface during a clinical trial at the Ottawa Civic Hospital

    NASA Astrophysics Data System (ADS)

    Coristine, Marjorie; Beeton, Carolyn; Tombaugh, Jo W.; Ahuja, J.; Belanger, Garry; Dillon, Richard F.; Currie, Shawn; Hind, E.

    1990-07-01

    During a clinical trial, emergency physicians and radiologists at the Ottawa Civic Hospital used IRIS (Integrated Radiological Information System) to process patients' x-rays, requisitions, and reports, and to have consultations, for 319 active cases. This paper discusses IRIS user interface issues raised during the clinical trial. The IRIS workstation consists of three major system components: 1) an image screen for viewing and enhancing images; 2) a control screen for presenting patient information, selecting images, and executing commands; and 3) a hands-free telephone for reporting activities and consultations. The control screen and hands-free telephone user interface allow physicians to navigate through patient files, select images and access reports, enter new reports, and perform remote consultations. Physicians were observed using the system during the trial and responded to questions about the user interface on an extensive debriefing interview after the trial. Overall, radiologists and emergency physicians were satisfied with IRIS control screen functionality and user interface. In a number of areas radiologists and emergency physicians differed in their user interface needs. Some features were found to be acceptable to one group of physicians but required modification to meet the needs of the other physician group. The data from the interviews, along with the comments from radiologists and emergency physicians provided important information for the revision of some features, and for the evolution of new features.

  19. Effects of prostaglandins and thromboxane analogues on bullock and dog iris sphincter preparations.

    PubMed Central

    Dong, Y. J.; Jones, R. L.

    1982-01-01

    1 The bullock iris sphincter was contracted by low concentrations of prostaglandin E2 (PGE2), 16, 16-dimethyl PGE2 and 17,18,19,20-tetranor-16-p-chlorophenoxy PGE2. Other compounds with thromboxane-like actions, for example 11,9-epoxymethano PGH2, were also potent spasmogens, ZK 36374, a stable carbacyclin, was a partial agonist on the PGE-sensitive system of this tissue. 2 The thromboxane antagonist, EP 045, had little effect on the action of PGE2 and 16,16-dimethyl PGE2 on the bullock iris. 3 The dog iris sphincter was sensitive to PGF2 alpha but not to PGE2 and 11,9-epoxymethano PGH2. 4 16,16-dimethyl PGE2 had very low activity on the dog iris in contrast to its high activity on the bullock iris. The reverse was found with the 17,18,19,20-tetranor-16-m-trifluoromethylphenoxy analogue of PGF2 alpha (ICI 81008). This indicates a considerable selectivity of action of the two analogues. 5 The results are discussed in relation to the existing knowledge of prostanoid receptors. PMID:6177369

  20. IRIS Toxicological Review of Benzo[a]pyrene (Final Report)

    EPA Science Inventory

    EPA has finalized the Integrated Risk Information System (IRIS) assessment of benzo[a]pyrene. This assessment addresses the potential cancer and noncancer human health effects from long-term exposure to benzo[a]pyrene. Now final, this assessment will update the toxicological info...

  1. IRIS Toxicological Review of Libby Amphibole Asbestos (Final Report)

    EPA Science Inventory

    EPA has finalized the, Toxicological Review of Libby Amphibole Asbestos: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  2. Cerium Oxide and Cerium Compounds

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 002F www.epa.gov / iris TOXICOLOGICAL REVIEW OF Cerium Oxide and Cerium Compounds ( CAS No . 1306 - 38 - 3 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2009 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This

  3. Libby Amphibole asbestos

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 11 / 002F www.epa.gov / iris TOXICOLOGICAL REVIEW OF LIBBY AMPHIBOLE ASBESTOS In Support of Summary Information on the Integrated Risk Information System ( IRIS ) December 2014 ( Note : This document is an assessment of the noncancer and cancer health effects associated with the inha

  4. Urea

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 10 / 005F www.epa.gov / iris TOXICOLOGICAL REVIEW OF UREA ( CAS No . 57 - 13 - 6 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) July 2011 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER This document has been reviewed in acc

  5. Thallium (I), soluble salts

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 001F www.epa.gov / iris TOXICOLOGICAL REVIEW OF THALLIUM AND COMPOUNDS ( CAS No . 7440 - 28 - 0 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2009 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document ha

  6. Barium and Compounds

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 05 / 001 www.epa.gov / iris TOXICOLOGICAL REVIEW OF BARIUM AND COMPOUNDS ( CAS No . 7440 - 39 - 3 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) March 1998 Minor revisions January 1999 Reference dose revised June 2005 U.S . Environmental Protec

  7. 1,1,1-Trichloroethane

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 03 / 013 www.epa.gov / iris TOXICOLOGICAL REVIEW OF 1,1,1 - TRICHLOROETHANE ( CAS No . 71 - 55 - 6 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) August 2007 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has bee

  8. IRIS Toxicological Review of Halogenated Platinum Salts and Platinum Compounds (External Review Draft)

    EPA Science Inventory

    EPA released the draft toxicological review for public comment under the Integrated Risk Information System (IRIS) Program. The original draft assessment (January 2009) has been archived but is available on this web page for the sake of transparency.

  9. IRIS Toxicological Review of Thallium and Compounds (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Thallium and Compounds: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  10. IRIS Toxicological Review of Trichloroacetic Acid (Tca) (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Trichloroacetic Acid: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  11. An inverse method to determine the mechanical properties of the iris in vivo

    PubMed Central

    2014-01-01

    Background Understanding the mechanical properties of the iris can help to have an insight into the eye diseases with abnormalities of the iris morphology. Material parameters of the iris were simply calculated relying on the ex vivo experiment. However, the mechanical response of the iris in vivo is different from that ex vivo, therefore, a method was put forward to determine the material parameters of the iris using the optimization method in combination with the finite element method based on the in vivo experiment. Material and methods Ocular hypertension was induced by rapid perfusion to the anterior chamber, during perfusion intraocular pressures in the anterior and posterior chamber were record by sensors, images of the anterior segment were captured by the ultrasonic system. The displacement of the characteristic points on the surface of the iris was calculated. A finite element model of the anterior chamber was developed using the ultrasonic image before perfusion, the multi-island genetic algorithm was employed to determine the material parameters of the iris by minimizing the difference between the finite element simulation and the experimental measurements. Results Material parameters of the iris in vivo were identified as the iris was taken as a nearly incompressible second-order Ogden solid. Values of the parameters μ1, α1, μ2 and α2 were 0.0861 ± 0.0080 MPa, 54.2546 ± 12.7180, 0.0754 ± 0.0200 MPa, and 48.0716 ± 15.7796 respectively. The stability of the inverse finite element method was verified, the sensitivity of the model parameters was investigated. Conclusion Material properties of the iris in vivo could be determined using the multi-island genetic algorithm coupled with the finite element method based on the experiment. PMID:24886660

  12. Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).

    PubMed

    West, A G; Goldsmith, G R; Matimati, I; Dawson, T E

    2011-08-30

    Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.

  13. IRIS: A database application system for diseases identification using FTIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Arshad, Ahmad Zulhilmi; Munajat, Yusof; Ibrahim, Raja Kamarulzaman Raja; Mahmood, Nasrul Humaimi

    2015-05-01

    Infrared information on diseases identification system (IRIS) is an application for diseases identification and analysis by using Fourier transform infrared (FTIR) spectroscopy. This is the preliminary step to gather information from the secondary data which was extracted from recognized various research and scientific paper, which are combined into a single database as in IRIS for our purpose of study. The importance of this database is to examine the fingerprint differences between normal and diseases cell or tissue. With the implementation of this application is it hopes that the diseases identification using FTIR spectroscopy would be more reliable and may assist either physicians, pathologists, or researchers to diagnose the certain type of disease efficiently.

  14. Infrared instrument support for HyspIRI-TIR

    NASA Astrophysics Data System (ADS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2012-10-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  15. High speed, multi-channel, thermal instrument development in support of HyspIRI-TIR

    NASA Astrophysics Data System (ADS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2011-10-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

  16. IRIS Toxicological Review of tert-Butyl Alcohol (tert-Butanol) ...

    EPA Pesticide Factsheets

    In August 2013, EPA released the draft literature searches and associated search strategies, evidence tables, and exposure response arrays for TBA to obtain input from stakeholders and the public prior to developing the draft IRIS assessment. Specifically, EPA was interested in comments on the following: Draft literature search strategies The approach for identifying studies The screening process for selecting pertinent studies The resulting list of pertinent studies Preliminary evidence tables The process for selecting studies to include in evidence tables The quality of the studies in the evidence tables The literature search strategy, which describes the processes for identifying scientific literature, contains the studies that EPA considered and selected to include in the evidence tables. The preliminary evidence tables and exposure-response arrays present the key study data in a standardized format. The evidence tables summarize the available critical scientific literature. The exposure-response figures provide a graphical representation of the responses at different levels of exposure for each study in the evidence table. EPA is undertaking a new health assessment for t-butyl alcohol (TBA) for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS and IRIS Summary of TBA that will be entered on the IRIS database. IRIS is an EPA da

  17. Seismological Data Stewardship at the IRIS DMC: The Role of a Dedicated Data Management System for Seismology

    NASA Astrophysics Data System (ADS)

    Benson, R. B.; Ahern, T. K.; Trabant, C.; Casey, R.

    2011-12-01

    Since the founding of the Incorporated Research Institutions for Seismology (IRIS) in 1984, there has been a core program for data management, quite unique at the time, dedicated solely to ensuring that data recorded by IRIS and it's partners had a perpetual data management framework that ensures data will be searchable, well-documented, and preserved so that future generations can, at it's core, have an accurate history of ground motion recordings. This goal is manifest in the IRIS Data Management System, or DMS. The mission of this NSF-EAR facility is "To provide reliable and efficient access to high quality seismological and related geophysical data, generated by IRIS and its domestic and international partners, and to enable all parties interested in using these data to do so in a straightforward and efficient manner". This presentation will focus on the data management business rules that capture the data life-cycle of 3 different segments of seismological and related geophysical data managed by IRIS: - Images and parametric information of historical analog data, - Non-real time quality-controlled digital data, - Real time data that streams into the DMC through a number of different protocols. We will describe how data collection, curation, and distribution to users are cataloged to provide an accurate provenance log of contributed data, which are passed along to both the consumer and network data provider. In addition, we will discuss the need and business rules that apply to metadata and how it is managed.

  18. Effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication.

    PubMed

    Dhir, L; Habib, N E; Monro, D M; Rakshit, S

    2010-06-01

    The purpose of this study was to investigate the effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication. Prospective non-comparative cohort study. Images of 15 subjects were captured before (enrolment), and 5, 10, and 15 min after instillation of mydriatics before routine cataract surgery. After cataract surgery, images were captured 2 weeks thereafter. Enrolled and test images (after pupillary dilation and after cataract surgery) were segmented to extract the iris. This was then unwrapped onto a rectangular format for normalization and a novel method using the Discrete Cosine Transform was applied to encode the image into binary bits. The numerical difference between two iris codes (Hamming distance, HD) was calculated. The HD between identification and enrolment codes was used as a score and was compared with a confidence threshold for specific equipment, giving a match or non-match result. The Correct Recognition Rate (CRR) and Equal Error Rates (EERs) were calculated to analyse overall system performance. After cataract surgery, perfect identification and verification was achieved, with zero false acceptance rate, zero false rejection rate, and zero EER. After pupillary dilation, non-elastic deformation occurs and a CRR of 86.67% and EER of 9.33% were obtained. Conventional circle-based localization methods are inadequate. Matching reliability decreases considerably with increase in pupillary dilation. Cataract surgery has no effect on iris pattern recognition, whereas pupil dilation may be used to defeat an iris-based authentication system.

  19. cis-1,2-Dichloroethylene

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 09 / 006 F www.epa.gov / iris TOXICOLOGICAL REVIEW OF cis - 1,2 - DICHLOROETHYLENE and trans - 1,2 - DICHLOROETHYLENE ( CAS Nos . cis : 156 - 59 - 2 ; trans : 156 - 60 - 5 ; mixture : 540 - 59 - 0 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS )

  20. Report: Congressionally Requested Information on EPA Utilization of Integrated Risk Information System

    EPA Pesticide Factsheets

    Report #13-P-0127, January 31, 2013. 85 percent of the EPA survey respondents reported that they have used IRIS as their primary source for cancer values and 81 percent have used IRIS as their primary source for non-cancer values.

  1. IRIS Toxicological Review of Inorganic Arsenic (Cancer) (2010 External Review Draft)

    EPA Science Inventory

    EPA's Science Advisory Board (SAB) conducted a review of the scientific basis supporting the human health cancer hazard and dose-response assessment of inorganic arsenic that will appear on the Integrated Risk Information System (IRIS) database. EPA revised the assessment and is...

  2. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This ...

  3. IRIS - A concept for microwave sensing of soil moisture and ocean salinity

    NASA Technical Reports Server (NTRS)

    Moghaddam, M.; Njoku, E.

    1997-01-01

    A concept is described for passive microwave sensing of soil moisture and ocean salinity from space. The Inflatable Radiometric Imaging System (IRIS) makes use of a large-diameter, offset-fed, parabolic-torus antenna with multiple feeds, in a conical pushbroom configuration.

  4. IRIS Toxicological Review of Ethylene Glycol Mono Butyl ...

    EPA Pesticide Factsheets

    EPA has finalized the Toxicological Review of Ethylene Glycol Mono Butyl Ether: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. N/A

  5. Development of a PCR Diagnostic System for Iris yellow spot tospovirus in Quarantine

    PubMed Central

    Shin, Yong-Gil; Rho, Jae-Young

    2014-01-01

    Iris yellow spot virus (IYSV) is a plant pathogenic virus which has been reported to continuously occur in onion bulbs, allium field crops, seed crops, lisianthus, and irises. In South Korea, IYSV is a “controlled” virus that has not been reported, and inspection is performed when crops of the genus Iris are imported into South Korea. In this study, reverse-transcription polymerase chain reaction (RT-PCR) and nested PCR inspection methods, which can detect IYSV, from imported crops of the genus Iris at quarantine sites, were developed. In addition, a modified positive plasmid, which can be used as a positive control during inspection, was developed. This modified plasmid can facilitate a more accurate inspection by enabling the examination of a laboratory contamination in an inspection system. The inspection methods that were developed in this study are expected to contribute, through the prompt and accurate inspection of IYSV at quarantine sites to the plant quarantine in South Korea. PMID:25506310

  6. Point spread function engineering for iris recognition system design.

    PubMed

    Ashok, Amit; Neifeld, Mark A

    2010-04-01

    Undersampling in the detector array degrades the performance of iris-recognition imaging systems. We find that an undersampling of 8 x 8 reduces the iris-recognition performance by nearly a factor of 4 (on CASIA iris database), as measured by the false rejection ratio (FRR) metric. We employ optical point spread function (PSF) engineering via a Zernike phase mask in conjunction with multiple subpixel shifted image measurements (frames) to mitigate the effect of undersampling. A task-specific optimization framework is used to engineer the optical PSF and optimize the postprocessing parameters to minimize the FRR. The optimized Zernike phase enhanced lens (ZPEL) imager design with one frame yields an improvement of nearly 33% relative to a thin observation module by bounded optics (TOMBO) imager with one frame. With four frames the optimized ZPEL imager achieves a FRR equal to that of the conventional imager without undersampling. Further, the ZPEL imager design using 16 frames yields a FRR that is actually 15% lower than that obtained with the conventional imager without undersampling.

  7. Comments on the Draft U.S. EPA Document Toxicological Review of Inorganic Arsenic: In Support of the Summary Information on the Integrated Risk Information System (IRIS)

    EPA Pesticide Factsheets

    The Organic Arsenical Products Task Force (OAPTF) hereby submits the appended list of materials from the scientific literature on inorganic arsenic for inclusion in the U.S. Environmental Protection Agency's (EPA) docket maintained in support of the Summary Information on the Integrated Risk Information System (IRIS) Report (Report)

  8. Polynomial algebra reveals diverging roles of the unfolded protein response in endothelial cells during ischemia-reperfusion injury.

    PubMed

    Le Pape, Sylvain; Dimitrova, Elena; Hannaert, Patrick; Konovalov, Alexander; Volmer, Romain; Ron, David; Thuillier, Raphaël; Hauet, Thierry

    2014-08-25

    The unfolded protein response (UPR)--the endoplasmic reticulum stress response--is found in various pathologies including ischemia-reperfusion injury (IRI). However, its role during IRI is still unclear. Here, by combining two different bioinformatical methods--a method based on ordinary differential equations (Time Series Network Inference) and an algebraic method (probabilistic polynomial dynamical systems)--we identified the IRE1α-XBP1 and the ATF6 pathways as the main UPR effectors involved in cell's adaptation to IRI. We validated these findings experimentally by assessing the impact of their knock-out and knock-down on cell survival during IRI. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  9. Integrating Iris and Signature Traits for Personal Authentication Using User-Specific Weighting

    PubMed Central

    Viriri, Serestina; Tapamo, Jules R.

    2012-01-01

    Biometric systems based on uni-modal traits are characterized by noisy sensor data, restricted degrees of freedom, non-universality and are susceptible to spoof attacks. Multi-modal biometric systems seek to alleviate some of these drawbacks by providing multiple evidences of the same identity. In this paper, a user-score-based weighting technique for integrating the iris and signature traits is presented. This user-specific weighting technique has proved to be an efficient and effective fusion scheme which increases the authentication accuracy rate of multi-modal biometric systems. The weights are used to indicate the importance of matching scores output by each biometrics trait. The experimental results show that our biometric system based on the integration of iris and signature traits achieve a false rejection rate (FRR) of 0.08% and a false acceptance rate (FAR) of 0.01%. PMID:22666032

  10. Off-Angle Iris Correction Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J; Thompson, Joseph T; Karakaya, Mahmut

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not accountmore » for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.« less

  11. IRIS Toxicological Review of 1,4-Dioxane (Final Report)

    EPA Science Inventory

    EPA announced the release of the final report, Toxicological Review of 1,4-Dioxane (CAS No. 123-91-1): In Support of Summary Information on the Integrated Risk Information System (IRIS). The final Toxicological Review of 1,4-dioxane provides scientific support and rationa...

  12. 2,2\\',4,4\\'-Tetrabromodiphenyl ether (BDE-47)

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 07 / 005F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 2,2 ' , 4,4 ' - TETRABROMODIPHENYL ETHER ( BDE - 47 ) ( CAS No . 5436 - 43 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Was

  13. IRIS Toxicological Review of Hydrogen Cyanide and Cyanide Salts (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Hydrogen Cyanide and Cyanide Salts: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  14. LearnAlaska Portal

    Science.gov Websites

    ESS (Employee Self Service) E-Travel Online Login IRIS FIN/PROC Login IRIS HRM Login LearnAlaska SFOA SharePoint Site TRIPS (Traveler Integrated Profile System) Vendor Self Service (VSS) Resources Alaska & Resources Manuals Payment Detail Report Salary Schedules SFOA SharePoint Site (SOA Only) Training

  15. IRIS Toxicological Review of 1,1,2,2-Tetrachloroethane (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of 1,1,2,2-Tetrachloroethane: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  16. IRIS Toxicological Review of Cis-& Trans-1,2-Dichloroethylene (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of cis- & trans-1,2-Dichloroethylene: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  17. A Field Study of an Iris Identification System

    DTIC Science & Technology

    2008-05-01

    conducted a field trial of a commercial iris identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in...identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in Mon- terey, CA. Scans were performed by US military guards

  18. Cysts of the Iris Pigment Epithelium. What Is New and Interesting? The 2016 Jose Rizal International Medal Lecture.

    PubMed

    Shields, Jerry A; Shields, Carol L

    2017-01-01

    Cysts of the iris pigment epithelium (IPE) can involve the pupillary margin, midzone, or peripheral location or can be free-floating in the aqueous or vitreous or lodged in the anterior chamber angle. Avariant of IPE cyst, known as iris flocculi, can be a marker for systemic thoracic aneurysm. Review of IPE cysts and description of new observations of the lesions. Review of IPE cysts. Lesions in 672 eyes were classified as of the pupillary margin (n = 49; 7%), midzone (n = 188; 28%), peripheral (n = 424; 63%), or dislodged/free-floating (n = 11; 2%). Cysts of the IPE occurred most often in young adults (21-40 years) (n = 229; 34%) manifesting with peripheral or midzonal cysts. The characteristic clinical features of pupillary margin cyst were teardrop configuration at the pupillary margin, midzonal cyst with fusiform brown appearance, peripheral cyst as iris stromal bulge, dislodged cyst as a brown lesion in the angle, and free-floating cyst with round mass moving by gravitational forces in the aqueous or vitreous. Ultrasound biomicroscopy and anterior segment optical coherence tomography demonstrated the lesions. Surgical intervention for drainage/resection was rarely necessary (<1%). Some (<1%) cysts were associated with iris nevus, iris melanoma, or ciliary body melanoma. Pupillary margin cysts (flocculi) can be found with dissecting thoracic aortic aneurysm, related to genetic mutation in smooth muscle of the iris and aorta. Cysts of the IPE most often affect the peripheral region (iridociliary) and rarely require intervention. These cysts can be associated with underlying iris or ciliary body nevus or melanoma. Patients with iris flocculi should be monitored for dissecting thoracic aneurysm. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.

  19. Intestinal ischemia/reperfusion injury triggers activation of innate toll-like receptor 4 and adaptive chemokine programs.

    PubMed

    Watson, M J; Ke, B; Shen, X-D; Gao, F; Busuttil, R W; Kupiec-Weglinski, J W; Farmer, D G

    2008-12-01

    Ischemia/reperfusion injury (IRI) is a major problem in intestinal transplantation. Toll-like receptor 4 (TLR4) has been implicated as a possible link between the innate and adaptive immune systems, however little data exists regarding TLR4 in intestinal IRI. The goal of this study is to evaluate the involvement of TLR4 in intestinal IRI and to assess the effect on T cell related chemokine programs. C57BL6 mice underwent 100 minutes of warm intestinal ischemia by SMA clamping. Control WT mice underwent laparotomy without vascular occlusion. Separate survival and analysis groups were performed, and intestinal tissue was harvested at 1 hour, 2 hours, 4 hours, and 24 hours post-reperfusion. Analysis included histology, CD3 immunostaining, myeloperoxidase activity, Western blot, and PCR. Survival was significantly worse in the IRI group vs control (50% vs. 100%). IRI caused severe histopathological injury including mucosal erosions and villous congestion and hemorrhage. Myeloperoxidase activity increased in a time-dependent manner after IRI (2.71 0.25 at 1 hour, 2.92 0.25 at 2 hours, 4 0.16 at 4 hours, 5.1 0.25 at 24 hours vs 0.47 0.11 controls, P < .05). Protein expression of TLR4 followed by NF-kappaB was increased after IRI. Additionally, mRNA production of IP-10, MIP-2, MCP-1, and RANTES was increased at all time-points, as was mRNA for ICAM-1 and E-selectin. This study is the first to demonstrate increased expression of TLR4 and NF-kappaB after warm intestinal IRI. This detrimental cascade may be initiated by TLR4 via NF-kappaB signaling pathways, implicating TLR4 as a potential therapeutic target for the prevention of intestinal IRI.

  20. FAK/Src family of kinases: protective or aggravating factor for ischemia reperfusion injury in nervous system?

    PubMed

    Bikis, Christos; Moris, Demetrios; Vasileiou, Ioanna; Patsouris, Eustratios; Theocharis, Stamatios

    2015-04-01

    The focal adhesion kinase (FAK) and the Src families of kinases are subfamilies of the non-receptor protein tyrosine kinases. FAK activity is regulated by gene amplification, alternative splicing and phosporylation/dephosphorylation. FAK/Src complex has been found to participate through various pathways in neuronal models of ischemia-reperfusion injury (IRI) with conflicting results. The aim of the present review is to summarize the currently available data on this subject. The MEDLINE/PubMed database was searched for publications with the medical subject heading IRI and FAK and/or Src, nervous system. We restricted our search till 2014. We identified 93 articles that were available in English as abstracts or/and full-text articles that were deemed appropriate for our review. FAK has been found to have a beneficial preconditioning effect on IRI through activation via the protein kinase C (PKC) pathway by anesthetic agents. Of great importance are the interactions between FAK/Src and VEGF that has been already detected as a protective mean for IRI. The effect of VEGF administration might depend on dose as well as on time of administration. A Ca(2+)/calmodulin-dependent protein kinase II or PKC inhibitors seem to have protective effects on IRI by inhibiting ion channels activation.

  1. RE:RE: Comments on the Draft US EPA Document Toxicological Review of Inorganic Arsenic: In Support of the Summary Information on the Integrated Risk Information System (IRIS).

    EPA Pesticide Factsheets

    Letter from the Organic Arsenical Products Task Force expressing concern about aspects of the Science Advisory Board Workgroup's review of a draft document Toxicological Review of Inorganic Arsenic: In Support of the Summary Information on the Integrated Risk Information System (IRIS) and decision not to grant more time to prepare for meeting.

  2. Comparison of Two IRI plasmasphere Extensions with GPS-TEC Observations

    NASA Technical Reports Server (NTRS)

    Gulyaeva, T. L.; Gallagher, Dennis L.

    2006-01-01

    Comparisons of two model results with Global Positioning System GPS-TEC measurements have been carried out for different latitudinal, solar activity, magnetic activity, diurnal and seasonal conditions. The models evaluated are the Global Core Plasma Model (GCPM-2000) and the IRI extension with Russian plasmasphere model (IRI*).Data of 23 observatories providing GPS-TEC and ionosonde data have been used. It is shown that IRI* plasmasphere electron density is greater than GCPM results by an order of magnitude at 6370 km altitude (one Earth's radius) with this excess growing to 2-3 orders of magnitude towards the GPS satellite altitude of 20000 km. Another source of model and GPS-TEC differences is a way of selection of the F2 layer peak parameters driving the models either with ITU-R (former CCIR) maps or ionosonde observations. Plasmasphere amendment to IRI improves accuracy of TEC model predictions because the plasmasphere contribution to the total TEC varies from 10% by daytime under quiet magnetic conditions to more than 50% by night under stormy conditions.

  3. Feedback in Action--The Mechanism of the Iris.

    ERIC Educational Resources Information Center

    Pingnet, B.; And Others

    1988-01-01

    Describes two demonstration experiments. Outlines a demonstration of the general principle of positive and negative feedback and the influence of time delays in feedback circuits. Elucidates the principle of negative feedback with a model of the iris of the eye. Emphasizes the importance of feedback in biological systems. (CW)

  4. 2,2\\',4,4\\',5-Pentabromodiphenyl ether (BDE-99)

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 07 / 006F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 2,2 ' , 4,4 ' , 5 - PENTABROMODIPHENYL ETHER ( BDE - 99 ) ( CAS No . 60348 - 60 - 9 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Washington ,

  5. 75 FR 16108 - Science Advisory Board Staff Office; Notification of a Public Teleconference and Public Meeting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ... Information System (IRIS) is an electronic database containing descriptive and quantitative toxicological... Office of Research and Development (ORD). In 2001, ORD developed a draft IRIS Toxicological Assessment..., the National Research Council (NRC) was requested to provide a scientific consultation on key...

  6. Variable orifice using an iris shutter

    DOEpatents

    Beeman, Raymond; Brajkovich, Steven J.

    1978-01-01

    A variable orifice forming mechanism utilizing an iris shutter arrangement adapted to control gas flow, conductance in vacuum systems, as a heat shield for furnace windows, as a beam shutter in sputtering operations, and in any other application requiring periodic or continuously-variable control of material, gas, or fluid flow.

  7. IRIS Toxicological Review of Ethylene Glycol Mono Butyl Ether (Egbe) (Final Report)

    EPA Science Inventory

    EPA has finalized the Toxicological Review of Ethylene Glycol Mono Butyl Ether: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  8. Evolution of iris colour in relation to cavity nesting and parental care in passerine birds.

    PubMed

    Davidson, Gabrielle L; Thornton, Alex; Clayton, Nicola S

    2017-01-01

    Strong selection pressures are known to act on animal coloration. Although many animals vary in eye colour, virtually no research has investigated the functional significance of these colour traits. Passeriformes have a range of iris colours, making them an ideal system to investigate how and why iris colour has evolved. Using phylogenetic comparative methods, we tested the hypothesis that conspicuous iris colour in passerine birds evolved in response to (a) coordination of offspring care and (b) cavity nesting, two traits thought to be involved in intra-specific gaze sensitivity. We found that iris colour and cooperative offspring care by two or more individuals evolved independently, suggesting that bright eyes are not important for coordinating parental care through eye gaze. Furthermore, we found that evolution between iris colour and nesting behaviour did occur in a dependent manner, but contrary to predictions, transitions to coloured eyes were not more frequent in cavity nesters than non-cavity nesters. Instead, our results indicate that selection away from having bright eyes was much stronger in non-cavity nesters than cavity nesters, perhaps because conspicuous eye coloration in species not concealed within a cavity would be more visible to predators. © 2017 The Authors.

  9. Evolution of iris colour in relation to cavity nesting and parental care in passerine birds

    PubMed Central

    Thornton, Alex

    2017-01-01

    Strong selection pressures are known to act on animal coloration. Although many animals vary in eye colour, virtually no research has investigated the functional significance of these colour traits. Passeriformes have a range of iris colours, making them an ideal system to investigate how and why iris colour has evolved. Using phylogenetic comparative methods, we tested the hypothesis that conspicuous iris colour in passerine birds evolved in response to (a) coordination of offspring care and (b) cavity nesting, two traits thought to be involved in intra-specific gaze sensitivity. We found that iris colour and cooperative offspring care by two or more individuals evolved independently, suggesting that bright eyes are not important for coordinating parental care through eye gaze. Furthermore, we found that evolution between iris colour and nesting behaviour did occur in a dependent manner, but contrary to predictions, transitions to coloured eyes were not more frequent in cavity nesters than non-cavity nesters. Instead, our results indicate that selection away from having bright eyes was much stronger in non-cavity nesters than cavity nesters, perhaps because conspicuous eye coloration in species not concealed within a cavity would be more visible to predators. PMID:28077686

  10. IRIS Arrays: Observing Wavefields at Multiple Scales and Frequencies

    NASA Astrophysics Data System (ADS)

    Sumy, D. F.; Woodward, R.; Frassetto, A.

    2014-12-01

    The Incorporated Research Institutions for Seismology (IRIS) provides instruments for creating and operating seismic arrays at a wide range of scales. As an example, for over thirty years the IRIS PASSCAL program has provided instruments to individual Principal Investigators to deploy arrays of all shapes and sizes on every continent. These arrays have ranged from just a few sensors to hundreds or even thousands of sensors, covering areas with dimensions of meters to thousands of kilometers. IRIS also operates arrays directly, such as the USArray Transportable Array (TA) as part of the EarthScope program. Since 2004, the TA has rolled across North America, at any given time spanning a swath of approximately 800 km by 2,500 km, and thus far sampling 2% of the Earth's surface. This achievement includes all of the lower-48 U.S., southernmost Canada, and now parts of Alaska. IRIS has also facilitated specialized arrays in polar environments and on the seafloor. In all cases, the data from these arrays are freely available to the scientific community. As the community of scientists who use IRIS facilities and data look to the future they have identified a clear need for new array capabilities. In particular, as part of its Wavefields Initiative, IRIS is exploring new technologies that can enable large, dense array deployments to record unaliased wavefields at a wide range of frequencies. Large-scale arrays might utilize multiple sensor technologies to best achieve observing objectives and optimize equipment and logistical costs. Improvements in packaging and power systems can provide equipment with reduced size, weight, and power that will reduce logistical constraints for large experiments, and can make a critical difference for deployments in harsh environments or other situations where rapid deployment is required. We will review the range of existing IRIS array capabilities with an overview of previous and current deployments and examples of data and results. We will review existing IRIS projects that explore new array capabilities and highlight future directions for IRIS instrumentation facilities.

  11. Texture Feature Extraction and Classification for Iris Diagnosis

    NASA Astrophysics Data System (ADS)

    Ma, Lin; Li, Naimin

    Appling computer aided techniques in iris image processing, and combining occidental iridology with the traditional Chinese medicine is a challenging research area in digital image processing and artificial intelligence. This paper proposes an iridology model that consists the iris image pre-processing, texture feature analysis and disease classification. To the pre-processing, a 2-step iris localization approach is proposed; a 2-D Gabor filter based texture analysis and a texture fractal dimension estimation method are proposed for pathological feature extraction; and at last support vector machines are constructed to recognize 2 typical diseases such as the alimentary canal disease and the nerve system disease. Experimental results show that the proposed iridology diagnosis model is quite effective and promising for medical diagnosis and health surveillance for both hospital and public use.

  12. Stimulants improve theory of mind in children with attention deficit/hyperactivity disorder.

    PubMed

    Maoz, Hagai; Tsviban, Lior; Gvirts, Hila Z; Shamay-Tsoory, Simone G; Levkovitz, Yechiel; Watemberg, Nathan; Bloch, Yuval

    2014-03-01

    Impairments in 'theory of mind' (ToM) were linked to social cognition and reciprocal relationships deficits in children with attention deficit/hyperactivity disorder (ADHD). Twenty-four children with ADHD (13 with inattentive type and 11 with combined type, mean age 10.2 years) completed the Interpersonal Reactivity Index (IRI), a self-reported empathy questionnaire. All children performed the 'faux pas' task and a computerized ToM task in two different sessions either with or without administration of methylphenidate (MPH). Administration of MPH was associated with an improvement in cognitive and affective ToM. Children with ADHD-combined type had significantly lower scores in total IRI and the fantasy scale compared to children with ADHD-inattentive type. We conclude that deficits in empathy and ToM may play an important role in the impairments in social cognition and peer relationship in children with ADHD, especially children a hyperactive component. Stimulants may improve ToM and empathic functions. Future studies including larger samples and additional cognitive tasks are warranted in order to generalize these results and to identify possible underlying mechanisms for improvement in ToM following the administration of MPH.

  13. Joint IRIS/PASSCAL UNAVCO Seismic and GPS Installations, Testing, and Development

    NASA Astrophysics Data System (ADS)

    Fowler, J.; Alvarez, M.; Beaudoin, B.; Jackson, M.; Feaux, K.; Ruud, O.; Andreatta, V.; Meertens, C.; Ingate, S.

    2002-12-01

    Future large-scale deformation initiatives such as EarthScope (http://www.earthscope.org/) will provide an opportunity for collocation and integration of GPS receivers and broadband and short period seismic instruments. Example integration targets include PBO backbone and cluster sites with USArray Transportable (Bigfoot) and Permanent Array. A GPS seismic integration and testing facility at the IRIS/PASSCAL Instrument Center in Socorro, NM is currently performing side-by-side testing of different seismometers, GPS receivers, communications hardware, power systems and data streaming software. One configuration tested uses an integrated VSAT data communications system and a broadband seismometer collocated with a geodetic quality GPS system. Data are routed through a VSAT hub and distributed to the UNAVCO Data Archive in Boulder and the IRIS Data Management Center in Seattle. Preliminary results indicate data availability approaching 100% with a maximum latency of 5 sec.

  14. Comparing an FPGA to a Cell for an Image Processing Application

    NASA Astrophysics Data System (ADS)

    Rakvic, Ryan N.; Ngo, Hau; Broussard, Randy P.; Ives, Robert W.

    2010-12-01

    Modern advancements in configurable hardware, most notably Field-Programmable Gate Arrays (FPGAs), have provided an exciting opportunity to discover the parallel nature of modern image processing algorithms. On the other hand, PlayStation3 (PS3) game consoles contain a multicore heterogeneous processor known as the Cell, which is designed to perform complex image processing algorithms at a high performance. In this research project, our aim is to study the differences in performance of a modern image processing algorithm on these two hardware platforms. In particular, Iris Recognition Systems have recently become an attractive identification method because of their extremely high accuracy. Iris matching, a repeatedly executed portion of a modern iris recognition algorithm, is parallelized on an FPGA system and a Cell processor. We demonstrate a 2.5 times speedup of the parallelized algorithm on the FPGA system when compared to a Cell processor-based version.

  15. Interferometric biosensing platform for multiplexed digital detection of viral pathogens and biomarkers

    NASA Astrophysics Data System (ADS)

    Daaboul, George

    Label-free optical biosensors have been established as proven tools for monitoring specific biomolecular interactions. However, compact and robust embodiments of such instruments have yet to be introduced in order to provide sensitive, quantitative, and high-throughput biosensing for low-cost research and clinical applications. Here we present the interferometric reflectance-imaging sensor (IRIS). IRIS allows sensitive label free analysis using an inexpensive and durable multi-color LED illumination source on a silicon based surface. IRIS monitors biomolecular interaction through measurement of biomass addition to the sensor's surface. We demonstrate the capability of this system to dynamically monitor antigen---antibody interactions with a noise floor of 5.2 pg/mm 2 and DNA single mismatch detection under isothermal melting conditions in an array format. Ensemble detection of binding events using IRIS did not provide the sensitivity needed for detection of infectious disease and biomarkers at clinically relevant concentrations. Therefore, a new approach was adapted to the IRIS platform that allowed the detection and identification of individual nanoparticles on the sensor's surface. The new detection method was termed single-particle IRIS (SP-IRIS). We developed two detection modalities for SP-IRIS. The first modality is when the target is a nanoparticle such as a virus. We verified that SP-IRIS can accurately detect and size individual viral particles. Then we demonstrated that single nanoparticle counting and sizing methodology on SP-IRIS leads to a specific and sensitive virus sensor that can be multiplexed. Finally, we developed an assay for the detection of Ebola and Marburg. A detection limit of 3 x 103 PFU/ml was demonstrated for vesicular stomatitis virus (VSV) pseudotyped with Ebola or Marburg virus glycoprotein. We have demonstrated that virus detection can be done in human whole blood directly without the need for sample preparation. The second modality of SP-IRIS we developed was single molecule counting of biomarkers utilizing a sandwich assay with detection probes labeled with gold nanoparticles. We demonstrated the use of single molecule counting in a nucleic acid assay for melanoma biomarker detection. We showed that a single molecule counting assay can lead to detection limits in the attomolar range. The improved sensitivity of IRIS utilizing single nanoparticle detection holds promise for a simple and low-cost technology for rapid virus detection and multiplexed molecular screening for clinical applications.

  16. FAQs about IRIs.

    ERIC Educational Resources Information Center

    Paris, Scott G.; Carpenter, Robert D.

    2003-01-01

    Provides information about informal reading inventories (IRI), an early reading assessment. Explains what IRIs are; who should administer an IRI; when and how to administer an IRI; the reliability of data from IRIs; and the limitations of IRIs. (PM)

  17. 2,2\\',3,3\\',4,4\\',5,5\\',6,6\\'-Decabromodiphenyl ether (BDE-209)

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 07 / 008F www.epa.gov / iris TOXICOLOGICAL REVIEW OF DECABROMODIPHENYL ETHER ( BDE - 209 ) ( CAS No . 1163 - 19 - 5 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This d

  18. A pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding.

    PubMed

    Yoshida, Yukinaga; Matsuda, Koji; Tamai, Naoto; Yoshizawa, Kai; Nikami, Toshiki; Ishiguro, Haruya; Tajiri, Hisao

    2014-01-01

    Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.

  19. Iris Image Classification Based on Hierarchical Visual Codebook.

    PubMed

    Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang

    2014-06-01

    Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.

  20. Immune reconstitution inflammatory syndrome in HIV and sporotrichosis coinfection: report of two cases and review of the literature.

    PubMed

    Lyra, Marcelo Rosandiski; Nascimento, Maria Letícia Fernandes Oliveira; Varon, Andréa Gina; Pimentel, Maria Inês Fernandes; Antonio, Liliane de Fátima; Saheki, Maurício Naoto; Bedoya-Pacheco, Sandro Javier; Valle, Antonio Carlos Francesconi do

    2014-01-01

    We report 2 cases of patients with immune reconstitution inflammatory syndrome (IRIS) associated with cutaneous disseminated sporotrichosis and human immunodeficiency virus (HIV) coinfection. The patients received specific treatment for sporotrichosis. However, after 4 and 5 weeks from the beginning of antiretroviral therapy, both patients experienced clinical exacerbation of skin lesions despite increased T CD4+ cells (T cells cluster of differentiation 4 positive) count and decreased viral load. Despite this exacerbation, subsequent mycological examination after systemic corticosteroid administration did not reveal fungal growth. Accordingly, they were diagnosed with IRIS. However, the sudden withdrawal of the corticosteroids resulted in the recurrence of IRIS symptoms. No serious adverse effects could be attributed to prednisone. We recommend corticosteroid treatment for mild-to-moderate cases of IRIS in sporotrichosis and HIV coinfection with close follow-up.

  1. Vagus nerve stimulation mediates protection from kidney ischemia-reperfusion injury through α7nAChR+ splenocytes.

    PubMed

    Inoue, Tsuyoshi; Abe, Chikara; Sung, Sun-Sang J; Moscalu, Stefan; Jankowski, Jakub; Huang, Liping; Ye, Hong; Rosin, Diane L; Guyenet, Patrice G; Okusa, Mark D

    2016-05-02

    The nervous and immune systems interact in complex ways to maintain homeostasis and respond to stress or injury, and rapid nerve conduction can provide instantaneous input for modulating inflammation. The inflammatory reflex referred to as the cholinergic antiinflammatory pathway regulates innate and adaptive immunity, and modulation of this reflex by vagus nerve stimulation (VNS) is effective in various inflammatory disease models, such as rheumatoid arthritis and inflammatory bowel disease. Effectiveness of VNS in these models necessitates the integration of neural signals and α7 nicotinic acetylcholine receptors (α7nAChRs) on splenic macrophages. Here, we sought to determine whether electrical stimulation of the vagus nerve attenuates kidney ischemia-reperfusion injury (IRI), which promotes the release of proinflammatory molecules. Stimulation of vagal afferents or efferents in mice 24 hours before IRI markedly attenuated acute kidney injury (AKI) and decreased plasma TNF. Furthermore, this protection was abolished in animals in which splenectomy was performed 7 days before VNS and IRI. In mice lacking α7nAChR, prior VNS did not prevent IRI. Conversely, adoptive transfer of VNS-conditioned α7nAChR splenocytes conferred protection to recipient mice subjected to IRI. Together, these results demonstrate that VNS-mediated attenuation of AKI and systemic inflammation depends on α7nAChR-positive splenocytes.

  2. Evaluation of a recirculating pond system for rearing juvenile freshwater mussels at White Sulphur Springs National Fish Hatchery, West Virginia, U.S.A.

    USGS Publications Warehouse

    Mummert, A.; Newcomb, T.J.; Neves, R.J.; Parker, B.

    2006-01-01

    A recirculating double-pond system at White Sulphur Springs National Fish Hatchery in West Virginia, U.S.A., was evaluated for suitability for culturing juvenile freshwater mussels. Newly metamorphosed juveniles of Villosa iris and Lampsilis fasciola were placed in the system, and their growth and survival were evaluated for 94 days. Throughout the study, parameters of water quality remained within ranges suitable for mussel survival. Planktonic algal densities in the pond system ranged from 2850 to 6892 cells/ml. Thirty-seven algal taxa were identified, primarily green algae (Chlorophyta), diatoms (Bacillariophyceae), and blue-green algae (Cyanoprokaryota). Over the culture period, juveniles of L. fasciola experienced significantly lower (p < 0.001) survival (6.3% ?? 4.5) than those of V. iris (49.8% ?? 14.5). The very low survival rate of L. fasciola may indicate a failure of the flow-through pond environment to meet its habitat requirements or that variable microhabitat conditions within culture containers existed. Growth did not differ significantly between the species (p = 0.13). Survival of V. iris and growth of both species were similar to previous trials to culture juvenile mussels. Survival rates as high as 66.4% at 93 days for V. iris suggest that juveniles of some riverine species can be successfully cultured in a recirculating pond environment.

  3. Iris Matching Based on Personalized Weight Map.

    PubMed

    Dong, Wenbo; Sun, Zhenan; Tan, Tieniu

    2011-09-01

    Iris recognition typically involves three steps, namely, iris image preprocessing, feature extraction, and feature matching. The first two steps of iris recognition have been well studied, but the last step is less addressed. Each human iris has its unique visual pattern and local image features also vary from region to region, which leads to significant differences in robustness and distinctiveness among the feature codes derived from different iris regions. However, most state-of-the-art iris recognition methods use a uniform matching strategy, where features extracted from different regions of the same person or the same region for different individuals are considered to be equally important. This paper proposes a personalized iris matching strategy using a class-specific weight map learned from the training images of the same iris class. The weight map can be updated online during the iris recognition procedure when the successfully recognized iris images are regarded as the new training data. The weight map reflects the robustness of an encoding algorithm on different iris regions by assigning an appropriate weight to each feature code for iris matching. Such a weight map trained by sufficient iris templates is convergent and robust against various noise. Extensive and comprehensive experiments demonstrate that the proposed personalized iris matching strategy achieves much better iris recognition performance than uniform strategies, especially for poor quality iris images.

  4. Extended depth of field in an intrinsically wavefront-encoded biometric iris camera

    NASA Astrophysics Data System (ADS)

    Bergkoetter, Matthew D.; Bentley, Julie L.

    2014-12-01

    This work describes a design process which greatly increases the depth of field of a simple three-element lens system intended for biometric iris recognition. The system is optimized to produce a point spread function which is insensitive to defocus, so that recorded images may be deconvolved without knowledge of the exact object distance. This is essentially a variation on the technique of wavefront encoding, however the desired encoding effect is achieved by aberrations intrinsic to the lens system itself, without the need for a pupil phase mask.

  5. Plasticity for axolotl lens regeneration is associated with age‐related changes in gene expression

    PubMed Central

    Sousounis, Konstantinos; Athippozhy, Antony T.; Voss, S. Randal

    2014-01-01

    Abstract Mexican axolotls lose potential for lens regeneration 2 weeks after hatching. We used microarrays to identify differently expressed genes before and after this critical time, using RNA isolated from iris. Over 3700 genes were identified as differentially expressed in response to lentectomy between young (7 days post‐hatching) and old (3 months post‐hatching) axolotl larvae. Strikingly, many of the genes were only expressed in the early or late iris. Genes that were highly expressed in young iris significantly enriched electron transport chain, transcription, metabolism, and cell cycle gene ontologies, all of which are associated with lens regeneration. In contrast, genes associated with cellular differentiation and tissue maturation were uniquely expressed in old iris. Many of these expression differences strongly suggest that young and old iris samples were collected before and after the spleen became developmentally competent to produce and secrete cells with humoral and innate immunity functions. Our study establishes the axolotl as a powerful model to investigate age‐related cellular differentiation and immune system ontogeny within the context of tissue regeneration. PMID:27499863

  6. Land Cover Classification of the Jornada Experimental Range with Simulated HyspIRI Data

    NASA Astrophysics Data System (ADS)

    Thorp, K. R.; French, A. N.

    2011-12-01

    The proposed NASA mission, HyspIRI, would facilitate the use of hyperspectral satellite remote sensing images for monitoring a variety of Earth system processes. We utilized four years of AVIRIS data of the USDA Jornada Experimental Range in southern New Mexico to simulate the visible and near-infrared bands of the planned HyspIRI satellite. Vegetation dynamics at Jornada has been the subject of several recent studies due to concerns of invasive plant species encroaching on native rangeland grasses. Our objective was to assess the added value of simulated HyspIRI images to appropriately classify rangeland vegetation. The AVIRIS images were georeferenced to an orthophoto of the region and 's6' was implemented for atmospheric correction. Images were resampled to simulate HyspIRI wavebands in the visible and near-infrared. Supervised image classification based on observed spectra of rangeland vegetation species was used to map spatial vegetation cover class and temporal dynamics over four years. Forthcoming results will identify the added value of hyperspectral images, as compared to broadband images, for monitoring vegetation dynamics at Jornada.

  7. Dependency of Optimal Parameters of the IRIS Template on Image Quality and Border Detection Error

    NASA Astrophysics Data System (ADS)

    Matveev, I. A.; Novik, V. P.

    2017-05-01

    Generation of a template containing spatial-frequency features of iris is an important stage of identification. The template is obtained by a wavelet transform in an image region specified by iris borders. One of the main characteristics of the identification system is the value of recognition error, equal error rate (EER) is used as criterion here. The optimal values (in sense of minimizing the EER) of wavelet transform parameters depend on many factors: image quality, sharpness, size of characteristic objects, etc. It is hard to isolate these factors and their influences. The work presents an attempt to study an influence of following factors to EER: iris segmentation precision, defocus level, noise level. Several public domain iris image databases were involved in experiments. The images were subjected to modelled distortions of said types. The dependencies of wavelet parameter and EER values from the distortion levels were build. It is observed that the increase of the segmentation error and image noise leads to the increase of the optimal wavelength of the wavelets, whereas the increase of defocus level leads to decreasing of this value.

  8. Hyperspectral optical imaging of human iris in vivo: characteristics of reflectance spectra

    NASA Astrophysics Data System (ADS)

    Medina, José M.; Pereira, Luís M.; Correia, Hélder T.; Nascimento, Sérgio M. C.

    2011-07-01

    We report a hyperspectral imaging system to measure the reflectance spectra of real human irises with high spatial resolution. A set of ocular prosthesis was used as the control condition. Reflectance data were decorrelated by the principal-component analysis. The main conclusion is that spectral complexity of the human iris is considerable: between 9 and 11 principal components are necessary to account for 99% of the cumulative variance in human irises. Correcting image misalignments associated with spontaneous ocular movements did not influence this result. The data also suggests a correlation between the first principal component and different levels of melanin present in the irises. It was also found that although the spectral characteristics of the first five principal components were not affected by the radial and angular position of the selected iridal areas, they affect the higher-order ones, suggesting a possible influence of the iris texture. The results show that hyperspectral imaging in the iris, together with adequate spectroscopic analyses provide more information than conventional colorimetric methods, making hyperspectral imaging suitable for the characterization of melanin and the noninvasive diagnosis of ocular diseases and iris color.

  9. IRIS Product Recommendations

    NASA Technical Reports Server (NTRS)

    Short, David A.

    2000-01-01

    This report presents the Applied Meteorology Unit's (AMU) evaluation of SIGMET Inc.'s Integrated Radar Information System (IRIS) Product Generator and recommendations for products emphasizing lightning and microburst tools. The IRIS Product Generator processes radar reflectivity data from the Weather Surveillance Radar, model 74C (WSR-74C), located on Patrick Air Force Base. The IRIS System was upgraded from version 6.12 to version 7.05 in late December 1999. A statistical analysis of atmospheric temperature variability over the Cape Canaveral Air Force Station (CCAFS) Weather Station provided guidance for the configuration of radar products that provide information on the mixed-phase (liquid and ice) region of clouds, between 0 C and -20 C. Mixed-phase processes at these temperatures are physically linked to electrification and the genesis of severe weather within convectively generated clouds. Day-to-day variations in the atmospheric temperature profile are of sufficient magnitude to warrant periodic reconfiguration of radar products intended for the interpretation of lightning and microburst potential of convectively generated clouds. The AMU also examined the radar volume-scan strategy to determine the scales of vertical gaps within the altitude range of the 0 C to -20 C isotherms over the Kennedy Space Center (KSC)/CCAFS area. This report present's two objective strategies for designing volume scans and proposes a modified scan strategy that reduces the average vertical gap by 37% as a means for improving radar observations of cloud characteristics in the critical 0 C to -20 C layer. The AMU recommends a total of 18 products, including 11 products that require use of the IRIS programming language and the IRIS User Product Insert feature. Included is a cell trends product and display, modeled after the WSR-88D cell trends display in use by the National Weather Service.

  10. The IRIS Federator: Accessing Seismological Data Across Data Centers

    NASA Astrophysics Data System (ADS)

    Trabant, C. M.; Van Fossen, M.; Ahern, T. K.; Weekly, R. T.

    2015-12-01

    In 2013 the International Federation of Digital Seismograph Networks (FDSN) approved a specification for web service interfaces for accessing seismological station metadata, time series and event parameters. Since then, a number of seismological data centers have implemented FDSN service interfaces, with more implementations in development. We have developed a new system called the IRIS Federator which leverages this standardization and provides the scientific community with a service for easy discovery and access of seismological data across FDSN data centers. These centers are located throughout the world and this work represents one model of a system for data collection across geographic and political boundaries.The main components of the IRIS Federator are a catalog of time series metadata holdings at each data center and a web service interface for searching the catalog. The service interface is designed to support client­-side federated data access, a model in which the client (software run by the user) queries the catalog and then collects the data from each identified center. By default the results are returned in a format suitable for direct submission to those web services, but could also be formatted in a simple text format for general data discovery purposes. The interface will remove any duplication of time series channels between data centers according to a set of business rules by default, however a user may request results with all duplicate time series entries included. We will demonstrate how client­-side federation is being incorporated into some of the DMC's data access tools. We anticipate further enhancement of the IRIS Federator to improve data discovery in various scenarios and to improve usefulness to communities beyond seismology.Data centers with FDSN web services: http://www.fdsn.org/webservices/The IRIS Federator query interface: http://service.iris.edu/irisws/fedcatalog/1/

  11. Performance of Solar Proxy Options of IRI-Plas Model for Equinox Seasons

    NASA Astrophysics Data System (ADS)

    Sezen, Umut; Gulyaeva, Tamara L.; Arikan, Feza

    2018-02-01

    International Reference Ionosphere (IRI) is the most acclaimed climatic model of the ionosphere. Since 2009, the range of the IRI model has been extended to the Global Positioning System (GPS) orbital height of 20,000 km in the plasmasphere. The new model, which is called IRI extended to Plasmasphere (IRI-Plas), can input not only the ionosonde foF2 and hmF2 but also the GPS-total electron content (TEC). IRI-Plas has been provided at www.ionolab.org, where online computation of ionospheric parameters is accomplished through a user-friendly interface. The solar proxies that are available in IRI-Plas can be listed as sunspot number (SSN1), SSN2, F10.7, global electron content (GEC), TEC, IG, Mg II, Lyman-α, and GEC_RZ. In this study, ionosonde foF2 data are compared with IRI-Plas foF2 values with the Consultative Committee International Radio (CCIR) and International Union of Radio Science (URSI) model choices for each solar proxy, with or without the GPS-TEC input for the equinox months of October 2011 and March 2015. It has been observed that the best fitting model choices in Root Mean Square (RMS) and Normalized RMS (NRMS) sense are the Jet Propulsion Laboratory global ionospheric maps-TEC input with Lyman-α solar proxy option for both months. The input of TEC definitely lowers the difference between the model and ionosonde foF2 values. The IG and Mg II solar proxies produce similar model foF2 values, and they usually are the second and third best fits to the ionosonde foF2 for the midlatitude ionosphere. In high-latitude regions, Jet Propulsion Laboratory global ionospheric map-TEC inputs to IRI-Plas with Lyman-α, GEC_RZ, and TEC solar proxies are the best choices. In equatorial region, the best fitting solar proxies are IG, Lyman-α, and Mg II.

  12. Performance Evaluation of Multimodal Multifeature Authentication System Using KNN Classification.

    PubMed

    Rajagopal, Gayathri; Palaniswamy, Ramamoorthy

    2015-01-01

    This research proposes a multimodal multifeature biometric system for human recognition using two traits, that is, palmprint and iris. The purpose of this research is to analyse integration of multimodal and multifeature biometric system using feature level fusion to achieve better performance. The main aim of the proposed system is to increase the recognition accuracy using feature level fusion. The features at the feature level fusion are raw biometric data which contains rich information when compared to decision and matching score level fusion. Hence information fused at the feature level is expected to obtain improved recognition accuracy. However, information fused at feature level has the problem of curse in dimensionality; here PCA (principal component analysis) is used to diminish the dimensionality of the feature sets as they are high dimensional. The proposed multimodal results were compared with other multimodal and monomodal approaches. Out of these comparisons, the multimodal multifeature palmprint iris fusion offers significant improvements in the accuracy of the suggested multimodal biometric system. The proposed algorithm is tested using created virtual multimodal database using UPOL iris database and PolyU palmprint database.

  13. Performance Evaluation of Multimodal Multifeature Authentication System Using KNN Classification

    PubMed Central

    Rajagopal, Gayathri; Palaniswamy, Ramamoorthy

    2015-01-01

    This research proposes a multimodal multifeature biometric system for human recognition using two traits, that is, palmprint and iris. The purpose of this research is to analyse integration of multimodal and multifeature biometric system using feature level fusion to achieve better performance. The main aim of the proposed system is to increase the recognition accuracy using feature level fusion. The features at the feature level fusion are raw biometric data which contains rich information when compared to decision and matching score level fusion. Hence information fused at the feature level is expected to obtain improved recognition accuracy. However, information fused at feature level has the problem of curse in dimensionality; here PCA (principal component analysis) is used to diminish the dimensionality of the feature sets as they are high dimensional. The proposed multimodal results were compared with other multimodal and monomodal approaches. Out of these comparisons, the multimodal multifeature palmprint iris fusion offers significant improvements in the accuracy of the suggested multimodal biometric system. The proposed algorithm is tested using created virtual multimodal database using UPOL iris database and PolyU palmprint database. PMID:26640813

  14. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    PubMed

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  15. Assessment of the NeQuick-2 and IRI-Plas 2017 models using global and long-term GNSS measurements

    NASA Astrophysics Data System (ADS)

    Okoh, Daniel; Onwuneme, Sylvester; Seemala, Gopi; Jin, Shuanggen; Rabiu, Babatunde; Nava, Bruno; Uwamahoro, Jean

    2018-05-01

    The global ionospheric models NeQuick and IRI-Plas have been widely used. However, their uncertainties are not clear at global scale and long term. In this paper, a climatologic assessment of the NeQuick and IRI-Plas models is investigated at a global scale from global navigation satellite system (GNSS) observations. GNSS observations from 36 globally distributed locations were used to evaluate performances of both NeQuick-2 and IRI-Plas 2017 models from January 2006 to July 2017, covering more than the 11-year period of a solar cycle. An hourly interval of diurnal profiles computed on monthly basis was used to measure deviations of the model estimations from corresponding GNSS VTEC observations. Results show that both models are fairly accurate in trends with the GNSS measurements. The NeQuick predictions were generally better than the IRI-Plas predictions in most of the stations and the times. The mean annual prediction errors for the IRI-Plas model typically varied from about 3 TECU at the high latitude stations to about 12 TECU at the low latitude stations, while for the NeQuick the values are respectively about 2-7 TECU. Out of a total 4497 months in which GNSS data were available for all the stations put together for the entire period covered in this work, the NeQuick model was observed to perform better in about 83% of the months while the IRI-Plas performed better in about 17% of the months. The IRI-Plas generally performed better than the NeQuick at certain locations (e.g. DAV1, KERG, and ADIS). For both models, the most of the deviations were witnessed during local daytimes and during seasons that receive maximum solar radiation for various locations. In particular, the IRI-Plas model predictions were improved during periods of increased solar activity at the low latitude stations. The IRI-Plas model overestimates the GNSS VTEC values, except during high solar activity years at some high latitude stations. The NeQuick underestimates the TEC values during the high solar activity years and overestimates it during local daytime for low and moderate solar activity years, but not as much as the IRI-Plas does.

  16. Toxoplasmosis-associated IRIS involving the CNS: a case report with longitudinal analysis of T cell subsets.

    PubMed

    Rb-Silva, Rita; Nobrega, Claudia; Reiriz, Eugénia; Almeida, Soraia; Sarmento-Castro, Rui; Correia-Neves, Margarida; Horta, Ana

    2017-01-13

    HIV-infected patients may present an unforeseen clinical worsening after initiating antiretroviral therapy known as immune reconstitution inflammatory syndrome (IRIS). This syndrome is characterized by a heightened inflammatory response toward infectious or non-infectious triggers, and it may affect different organs. Diagnosis of IRIS involving the central nervous system (CNS-IRIS) is challenging due to heterogeneous manifestations, absence of biomarkers to identify this condition, risk of long-term sequelae and high mortality. Hence, a deeper knowledge of CNS-IRIS pathogenesis is needed. A 37-year-old man was diagnosed with AIDS and cerebral toxoplasmosis. Anti-toxoplasma treatment was initiated immediately, followed by active antiretroviral therapy (HAART) 1 month later. At 2 months of HAART, he presented with progressive hyposensitivity of the right lower limb associated with brain and dorsal spinal cord lesions, compatible with paradoxical toxoplasmosis-associated CNS-IRIS, a condition with very few reported cases. A stereotactic biopsy was planned but was postponed based on its inherent risks. Patient showed clinical improvement with no requirement of corticosteroid therapy. Routine laboratorial analysis was complemented with longitudinal evaluation of blood T cell subsets at 0, 1, 2, 3 and 6 months upon HAART initiation. A control group composed by 9 HIV-infected patients from the same hospital but with no IRIS was analysed for comparison. The CNS-IRIS patient showed lower percentage of memory CD4 + T cells and higher percentage of activated CD4 + T cells at HAART initiation. The percentage of memory CD4 + T cells drastically increased at 1 month after HAART initiation and became higher in comparison to the control group until clinical recovery onset; the percentage of memory CD8 + T cells was consistently lower throughout follow-up. Interestingly, the percentage of regulatory T cells (Treg) on the CNS-IRIS patient reached a minimum around 1 month before symptoms onset. Although both stereotactic biopsies and steroid therapy might be of use in CNS-IRIS cases and should be considered for these patients, they might be unnecessary to achieve clinical improvement as shown in this case. Immunological characterization of more CNS-IRIS cases is essential to shed some light on the pathogenesis of this condition.

  17. Immune reconstitution inflammatory syndrome associated with Kaposi sarcoma: higher incidence and mortality in Africa than in the UK.

    PubMed

    Letang, Emilio; Lewis, James J; Bower, Mark; Mosam, Anisa; Borok, Margareth; Campbell, Thomas B; Naniche, Denise; Newsom-Davis, Tom; Shaik, Fahmida; Fiorillo, Suzanne; Miro, Jose M; Schellenberg, David; Easterbrook, Philippa J

    2013-06-19

    To assess the incidence, predictors, and outcomes of Kaposi sarcoma-associated paradoxical immune reconstitution inflammatory syndrome (KS-IRIS) in antiretroviral therapy (ART)-naive HIV-infected patients with Kaposi sarcoma initiating ART in both well resourced and limited-resourced settings. Pooled analysis of three prospective cohorts of ART-naive HIV-infected patients with Kaposi sarcoma from sub-Saharan Africa (SSA) and one from the UK. KS-IRIS case definition was standardized across sites. Cox regression and Kaplan-Meier survival analysis were used to identify the incidence and predictors of KS-IRIS and Kaposi sarcoma-associated mortality. Fifty-eight of 417 (13.9%) eligible individuals experienced KS-IRIS with an incidence 2.5 times higher in the African vs. European cohorts (P=0.001). ART alone as initial Kaposi sarcoma treatment (hazard ratio 2.97, 95% confidence interval (CI) 1.02-8.69); T1 Kaposi sarcoma stage (hazard ratio 2.96, 95% CI 1.26-6.94); and plasma HIV-1 RNA more than 5 log₁₀ copies/ml (hazard ratio 2.14, 95% CI 1.25-3.67) independently predicted KS-IRIS at baseline. Detectable plasma Kaposi sarcoma-associated herpes virus (KSHV) DNA additionally predicted KS-IRIS among the 259 patients with KSHV DNA assessed (hazard ratio 2.98, 95% CI 1.23-7.19). Nineteen KS-IRIS patients died, all in SSA. Kaposi sarcoma mortality was 3.3-fold higher in Africa, and was predicted by KS-IRIS (hazard ratio 19.24, CI 7.62-48.58), lack of chemotherapy (hazard ratio 2.35, 95% CI 1.09-5.05), pre-ART CD4 cell count less than 200 cells/μl (hazard ratio 2.04, 95% CI 0.99-4.2), and detectable baseline KSHV DNA (hazard ratio 2.12, 95% CI 0.94-4.77). KS-IRIS incidence and mortality are higher in SSA than in the UK. This is largely explained by the more advanced Kaposi sarcoma disease and lower chemotherapy availability. KS-IRIS is a major contributor to Kaposi sarcoma-associated mortality in Africa. Our results support the need to increase awareness on KS-IRIS, encourage earlier presentation, referral and diagnosis of Kaposi sarcoma, and advocate on access to systemic chemotherapy in Africa. © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins

  18. NOVEL OBSERVATIONS AND POTENTIAL APPLICATIONS USING DIGITAL INFRARED IRIS IMAGING

    PubMed Central

    Roberts, Daniel K.; Lukic, Ana; Yang, Yongyi; Moroi, Sayoko E.; Wilensky, Jacob T.; Wernick, Miles N.

    2017-01-01

    Digital infrared (IR) iris photography using a modified digital camera system was carried out on about 300 subjects seen during routine clinical care and research at one facility. Since this image database offered opportunity to gain new insight into the potential utility of IR iris imaging, it was surveyed for unique image patterns. Then, a selection of photos was compiled that would illustrate the spectrum of this imaging experience. Potentially informative image patterns were observed in subjects with cataracts, diabetic retinopathy, Posner-Schlossman syndrome, iridociliary cysts, long anterior lens zonules, nevi, oculocutaneous albinism, pigment dispersion syndrome, pseudophakia, suspected vascular anomaly, and trauma. Image patterns were often unanticipated regardless of pre-existing information and suggest that IR iris imaging may have numerous potential clinical and research applications, some of which may still not be recognized. These observations suggest further development and study of this technology. PMID:19320317

  19. KSC-2013-2503

    NASA Image and Video Library

    2013-05-30

    VANDENBERG AFB, Calif. – Engineers prepare to install a radial retraction system on NASA's IRIS spacecraft after its connection to the nose of an Orbital Sciences Pegasus XL rocket that will lift the solar observatory into orbit in June. The work is taking place in a hangar at Vandenberg Air Force Base where IRIS, short for Interface Region Imaging Spectrograph, is being prepared for launch on a Pegasus XL rocket. Scheduled for launch from Vandenberg June 26, IRIS will open a new window of discovery by tracing the flow of energy and plasma through the chromospheres and transition region into the sun’s corona using spectrometry and imaging. IRIS fills a crucial gap in our ability to advance studies of the sun-to-Earth connection by tracing the flow of energy and plasma through the foundation of the corona and the region around the sun known as the heliosphere. Photo credit: NASA/Randy Beaudoin

  20. KSC-2013-2504

    NASA Image and Video Library

    2013-05-30

    VANDENBERG AFB, Calif. – Engineers install a radial retraction system on NASA's IRIS spacecraft after its connection to the nose of an Orbital Sciences Pegasus XL rocket that will lift the solar observatory into orbit in June. The work is taking place in a hangar at Vandenberg Air Force Base where IRIS, short for Interface Region Imaging Spectrograph, is being prepared for launch on a Pegasus XL rocket. Scheduled for launch from Vandenberg June 26, IRIS will open a new window of discovery by tracing the flow of energy and plasma through the chromospheres and transition region into the sun’s corona using spectrometry and imaging. IRIS fills a crucial gap in our ability to advance studies of the sun-to-Earth connection by tracing the flow of energy and plasma through the foundation of the corona and the region around the sun known as the heliosphere. Photo credit: NASA/Randy Beaudoin

Top