Sample records for system roms model

  1. Development and Utilization of Regional Oceanic Modeling System (ROMS). Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with the Regional Oceanic Modeling System (ROMS). Mixing in the Ocean Surface Layer Using the Regional Oceanic Modeling System (ROMS).

    DTIC Science & Technology

    2011-09-30

    community use for ROMS is biogeochemisty: chemical cycles, water quality, blooms , micro-nutrients, larval dispersal, biome transitions, and coupling to...J.C. McWilliams, X. Capet, and J. Kurian, 2010: Heat balance and eddies in the Peru- Chile Current System. Climate Dynamics, 37, in press. doi10.1007

  2. Power flow prediction in vibrating systems via model reduction

    NASA Astrophysics Data System (ADS)

    Li, Xianhui

    This dissertation focuses on power flow prediction in vibrating systems. Reduced order models (ROMs) are built based on rational Krylov model reduction which preserve power flow information in the original systems over a specified frequency band. Stiffness and mass matrices of the ROMs are obtained by projecting the original system matrices onto the subspaces spanned by forced responses. A matrix-free algorithm is designed to construct ROMs directly from the power quantities at selected interpolation frequencies. Strategies for parallel implementation of the algorithm via message passing interface are proposed. The quality of ROMs is iteratively refined according to the error estimate based on residual norms. Band capacity is proposed to provide a priori estimate of the sizes of good quality ROMs. Frequency averaging is recast as ensemble averaging and Cauchy distribution is used to simplify the computation. Besides model reduction for deterministic systems, details of constructing ROMs for parametric and nonparametric random systems are also presented. Case studies have been conducted on testbeds from Harwell-Boeing collections. Input and coupling power flow are computed for the original systems and the ROMs. Good agreement is observed in all cases.

  3. Submesoscale Flows and Mixing in the Oceanic Surface Layer Using the Regional Oceanic Modeling System (ROMS)

    DTIC Science & Technology

    2014-09-30

    continuation of the evolution of the Regional Oceanic Modeling System (ROMS) as a multi-scale, multi-process model and its utilization for...hydrostatic component of ROMS (Kanarska et al., 2007) is required to increase its efficiency and generality. The non-hydrostatic ROMS involves the solution...instability and wind-driven mixing. For the computational regime where those processes can be partially, but not yet fully resolved, it will

  4. Parallel Computation of the Regional Ocean Modeling System (ROMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, P; Song, Y T; Chao, Y

    2005-04-05

    The Regional Ocean Modeling System (ROMS) is a regional ocean general circulation modeling system solving the free surface, hydrostatic, primitive equations over varying topography. It is free software distributed world-wide for studying both complex coastal ocean problems and the basin-to-global scale ocean circulation. The original ROMS code could only be run on shared-memory systems. With the increasing need to simulate larger model domains with finer resolutions and on a variety of computer platforms, there is a need in the ocean-modeling community to have a ROMS code that can be run on any parallel computer ranging from 10 to hundreds ofmore » processors. Recently, we have explored parallelization for ROMS using the MPI programming model. In this paper, an efficient parallelization strategy for such a large-scale scientific software package, based on an existing shared-memory computing model, is presented. In addition, scientific applications and data-performance issues on a couple of SGI systems, including Columbia, the world's third-fastest supercomputer, are discussed.« less

  5. Recent Enhancements to the Development of CFD-Based Aeroelastic Reduced-Order Models

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.

    2007-01-01

    Recent enhancements to the development of CFD-based unsteady aerodynamic and aeroelastic reduced-order models (ROMs) are presented. These enhancements include the simultaneous application of structural modes as CFD input, static aeroelastic analysis using a ROM, and matched-point solutions using a ROM. The simultaneous application of structural modes as CFD input enables the computation of the unsteady aerodynamic state-space matrices with a single CFD execution, independent of the number of structural modes. The responses obtained from a simultaneous excitation of the CFD-based unsteady aerodynamic system are processed using system identification techniques in order to generate an unsteady aerodynamic state-space ROM. Once the unsteady aerodynamic state-space ROM is generated, a method for computing the static aeroelastic response using this unsteady aerodynamic ROM and a state-space model of the structure, is presented. Finally, a method is presented that enables the computation of matchedpoint solutions using a single ROM that is applicable over a range of dynamic pressures and velocities for a given Mach number. These enhancements represent a significant advancement of unsteady aerodynamic and aeroelastic ROM technology.

  6. Regression-based reduced-order models to predict transient thermal output for enhanced geothermal systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mudunuru, Maruti Kumar; Karra, Satish; Harp, Dylan Robert

    Reduced-order modeling is a promising approach, as many phenomena can be described by a few parameters/mechanisms. An advantage and attractive aspect of a reduced-order model is that it is computational inexpensive to evaluate when compared to running a high-fidelity numerical simulation. A reduced-order model takes couple of seconds to run on a laptop while a high-fidelity simulation may take couple of hours to run on a high-performance computing cluster. The goal of this paper is to assess the utility of regression-based reduced-order models (ROMs) developed from high-fidelity numerical simulations for predicting transient thermal power output for an enhanced geothermal reservoirmore » while explicitly accounting for uncertainties in the subsurface system and site-specific details. Numerical simulations are performed based on equally spaced values in the specified range of model parameters. Key sensitive parameters are then identified from these simulations, which are fracture zone permeability, well/skin factor, bottom hole pressure, and injection flow rate. We found the fracture zone permeability to be the most sensitive parameter. The fracture zone permeability along with time, are used to build regression-based ROMs for the thermal power output. The ROMs are trained and validated using detailed physics-based numerical simulations. Finally, predictions from the ROMs are then compared with field data. We propose three different ROMs with different levels of model parsimony, each describing key and essential features of the power production curves. The coefficients in the proposed regression-based ROMs are developed by minimizing a non-linear least-squares misfit function using the Levenberg–Marquardt algorithm. The misfit function is based on the difference between numerical simulation data and reduced-order model. ROM-1 is constructed based on polynomials up to fourth order. ROM-1 is able to accurately reproduce the power output of numerical simulations for low values of permeabilities and certain features of the field-scale data. ROM-2 is a model with more analytical functions consisting of polynomials up to order eight, exponential functions and smooth approximations of Heaviside functions, and accurately describes the field-data. At higher permeabilities, ROM-2 reproduces numerical results better than ROM-1, however, there is a considerable deviation from numerical results at low fracture zone permeabilities. ROM-3 consists of polynomials up to order ten, and is developed by taking the best aspects of ROM-1 and ROM-2. ROM-1 is relatively parsimonious than ROM-2 and ROM-3, while ROM-2 overfits the data. ROM-3 on the other hand, provides a middle ground for model parsimony. Based on R 2-values for training, validation, and prediction data sets we found that ROM-3 is better model than ROM-2 and ROM-1. For predicting thermal drawdown in EGS applications, where high fracture zone permeabilities (typically greater than 10 –15 m 2) are desired, ROM-2 and ROM-3 outperform ROM-1. As per computational time, all the ROMs are 10 4 times faster when compared to running a high-fidelity numerical simulation. In conclusion, this makes the proposed regression-based ROMs attractive for real-time EGS applications because they are fast and provide reasonably good predictions for thermal power output.« less

  7. Regression-based reduced-order models to predict transient thermal output for enhanced geothermal systems

    DOE PAGES

    Mudunuru, Maruti Kumar; Karra, Satish; Harp, Dylan Robert; ...

    2017-07-10

    Reduced-order modeling is a promising approach, as many phenomena can be described by a few parameters/mechanisms. An advantage and attractive aspect of a reduced-order model is that it is computational inexpensive to evaluate when compared to running a high-fidelity numerical simulation. A reduced-order model takes couple of seconds to run on a laptop while a high-fidelity simulation may take couple of hours to run on a high-performance computing cluster. The goal of this paper is to assess the utility of regression-based reduced-order models (ROMs) developed from high-fidelity numerical simulations for predicting transient thermal power output for an enhanced geothermal reservoirmore » while explicitly accounting for uncertainties in the subsurface system and site-specific details. Numerical simulations are performed based on equally spaced values in the specified range of model parameters. Key sensitive parameters are then identified from these simulations, which are fracture zone permeability, well/skin factor, bottom hole pressure, and injection flow rate. We found the fracture zone permeability to be the most sensitive parameter. The fracture zone permeability along with time, are used to build regression-based ROMs for the thermal power output. The ROMs are trained and validated using detailed physics-based numerical simulations. Finally, predictions from the ROMs are then compared with field data. We propose three different ROMs with different levels of model parsimony, each describing key and essential features of the power production curves. The coefficients in the proposed regression-based ROMs are developed by minimizing a non-linear least-squares misfit function using the Levenberg–Marquardt algorithm. The misfit function is based on the difference between numerical simulation data and reduced-order model. ROM-1 is constructed based on polynomials up to fourth order. ROM-1 is able to accurately reproduce the power output of numerical simulations for low values of permeabilities and certain features of the field-scale data. ROM-2 is a model with more analytical functions consisting of polynomials up to order eight, exponential functions and smooth approximations of Heaviside functions, and accurately describes the field-data. At higher permeabilities, ROM-2 reproduces numerical results better than ROM-1, however, there is a considerable deviation from numerical results at low fracture zone permeabilities. ROM-3 consists of polynomials up to order ten, and is developed by taking the best aspects of ROM-1 and ROM-2. ROM-1 is relatively parsimonious than ROM-2 and ROM-3, while ROM-2 overfits the data. ROM-3 on the other hand, provides a middle ground for model parsimony. Based on R 2-values for training, validation, and prediction data sets we found that ROM-3 is better model than ROM-2 and ROM-1. For predicting thermal drawdown in EGS applications, where high fracture zone permeabilities (typically greater than 10 –15 m 2) are desired, ROM-2 and ROM-3 outperform ROM-1. As per computational time, all the ROMs are 10 4 times faster when compared to running a high-fidelity numerical simulation. In conclusion, this makes the proposed regression-based ROMs attractive for real-time EGS applications because they are fast and provide reasonably good predictions for thermal power output.« less

  8. Parameterized reduced-order models using hyper-dual numbers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fike, Jeffrey A.; Brake, Matthew Robert

    2013-10-01

    The goal of most computational simulations is to accurately predict the behavior of a real, physical system. Accurate predictions often require very computationally expensive analyses and so reduced order models (ROMs) are commonly used. ROMs aim to reduce the computational cost of the simulations while still providing accurate results by including all of the salient physics of the real system in the ROM. However, real, physical systems often deviate from the idealized models used in simulations due to variations in manufacturing or other factors. One approach to this issue is to create a parameterized model in order to characterize themore » effect of perturbations from the nominal model on the behavior of the system. This report presents a methodology for developing parameterized ROMs, which is based on Craig-Bampton component mode synthesis and the use of hyper-dual numbers to calculate the derivatives necessary for the parameterization.« less

  9. Development and Utilization of Regional Oceanic Modeling System (ROMS) & Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with ROMS

    DTIC Science & Technology

    2010-09-30

    and Ecosystems: An important community use for ROMS is biogeochemisty: chemical cycles, water quality, blooms , micro-nutrients, larval dispersal... Chile current system. J. Climate, submitted. Colas, F., X. Capet, and J. McWilliams, 2010b: Mesoscale eddy buoyancy flux and eddy-induced

  10. Numerical Modeling of ROM Panel Closures at WIPP

    NASA Astrophysics Data System (ADS)

    Herrick, C. G.

    2016-12-01

    The Waste Isolation Pilot Plant (WIPP) in New Mexico is a U.S. DOE geologic repository for permanent disposal of defense-related transuranic (TRU) waste. Waste is emplaced in panels excavated in a bedded salt formation (Salado Fm.) at 655 m bgs. In 2014 the U.S. EPA approved the new Run-of-Mine Panel Closure System (ROMPCS) for WIPP. The closure system consists of 100 feet of run-of-mine (ROM) salt sandwiched between two barriers. Nuclear Waste Partnership LLC (the M&O contractor for WIPP) initiated construction of the ROMPCS. The design calls for three horizontal ROM salt layers at different compaction levels ranging from 70-85% intact salt density. Due to panel drift size constraints and equipment availability the design was modified. Three prototype panel closures were constructed: two having two layers of compacted ROM salt (one closure had 1% water added) and a third consisting of simply ROM salt with no layering or added water. Sampling of the prototype ROMPCS layers was conducted to determine the following ROM salt parameters: thickness, moisture content, emplaced density, and grain-size distribution. Previous modeling efforts were performed without knowledge of these ROM salt parameters. This modeling effort incorporates them. The program-accepted multimechanism deformation model is used to model intact salt room creep closure. An advanced crushed salt model is used to model the ROM salt. Comparison of the two models' results with the prototypes' behavior is given. Our goal is to develop a realistic, reliable model that can be used for ROM salt applications at WIPP. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U. S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S Department of Energy SAND2016-7259A

  11. Errors from approximation of ODE systems with reduced order models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vassilevska, Tanya

    2016-12-30

    This is a code to calculate the error from approximation of systems of ordinary differential equations (ODEs) by using Proper Orthogonal Decomposition (POD) Reduced Order Models (ROM) methods and to compare and analyze the errors for two POD ROM variants. The first variant is the standard POD ROM, the second variant is a modification of the method using the values of the time derivatives (a.k.a. time-derivative snapshots). The code compares the errors from the two variants under different conditions.

  12. Reduced Order Modeling for Prediction and Control of Large-Scale Systems.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalashnikova, Irina; Arunajatesan, Srinivasan; Barone, Matthew Franklin

    2014-05-01

    This report describes work performed from June 2012 through May 2014 as a part of a Sandia Early Career Laboratory Directed Research and Development (LDRD) project led by the first author. The objective of the project is to investigate methods for building stable and efficient proper orthogonal decomposition (POD)/Galerkin reduced order models (ROMs): models derived from a sequence of high-fidelity simulations but having a much lower computational cost. Since they are, by construction, small and fast, ROMs can enable real-time simulations of complex systems for onthe- spot analysis, control and decision-making in the presence of uncertainty. Of particular interest tomore » Sandia is the use of ROMs for the quantification of the compressible captive-carry environment, simulated for the design and qualification of nuclear weapons systems. It is an unfortunate reality that many ROM techniques are computationally intractable or lack an a priori stability guarantee for compressible flows. For this reason, this LDRD project focuses on the development of techniques for building provably stable projection-based ROMs. Model reduction approaches based on continuous as well as discrete projection are considered. In the first part of this report, an approach for building energy-stable Galerkin ROMs for linear hyperbolic or incompletely parabolic systems of partial differential equations (PDEs) using continuous projection is developed. The key idea is to apply a transformation induced by the Lyapunov function for the system, and to build the ROM in the transformed variables. It is shown that, for many PDE systems including the linearized compressible Euler and linearized compressible Navier-Stokes equations, the desired transformation is induced by a special inner product, termed the “symmetry inner product”. Attention is then turned to nonlinear conservation laws. A new transformation and corresponding energy-based inner product for the full nonlinear compressible Navier-Stokes equations is derived, and it is demonstrated that if a Galerkin ROM is constructed in this inner product, the ROM system energy will be bounded in a way that is consistent with the behavior of the exact solution to these PDEs, i.e., the ROM will be energy-stable. The viability of the linear as well as nonlinear continuous projection model reduction approaches developed as a part of this project is evaluated on several test cases, including the cavity configuration of interest in the targeted application area. In the second part of this report, some POD/Galerkin approaches for building stable ROMs using discrete projection are explored. It is shown that, for generic linear time-invariant (LTI) systems, a discrete counterpart of the continuous symmetry inner product is a weighted L2 inner product obtained by solving a Lyapunov equation. This inner product was first proposed by Rowley et al., and is termed herein the “Lyapunov inner product“. Comparisons between the symmetry inner product and the Lyapunov inner product are made, and the performance of ROMs constructed using these inner products is evaluated on several benchmark test cases. Also in the second part of this report, a new ROM stabilization approach, termed “ROM stabilization via optimization-based eigenvalue reassignment“, is developed for generic LTI systems. At the heart of this method is a constrained nonlinear least-squares optimization problem that is formulated and solved numerically to ensure accuracy of the stabilized ROM. Numerical studies reveal that the optimization problem is computationally inexpensive to solve, and that the new stabilization approach delivers ROMs that are stable as well as accurate. Summaries of “lessons learned“ and perspectives for future work motivated by this LDRD project are provided at the end of each of the two main chapters.« less

  13. CD-ROM: Potential and Pitfalls.

    ERIC Educational Resources Information Center

    Dreiss, L. Jack; Bashir, Shahzad

    1990-01-01

    Examines issues surrounding CD-ROM as an organizational information management tool: (1) the CD-ROM market; (2) pitfalls, including compatibility, effect on existing information systems, fear of obsolescence, protection of sensitive information, and lack of successful role models; and (3) factors that will fuel growth, including greater…

  14. Construction of energy-stable projection-based reduced order models

    DOE PAGES

    Kalashnikova, Irina; Barone, Matthew F.; Arunajatesan, Srinivasan; ...

    2014-12-15

    Our paper aims to unify and extend several approaches for building stable projection-based reduced order models (ROMs) using the energy method and the concept of “energy-stability”. Attention is focused on linear time-invariant (LTI) systems. First, an approach for building energy stable Galerkin ROMs for linear hyperbolic or incompletely parabolic systems of partial differential equations (PDEs) using continuous projection is proposed. The key idea is to apply to the system a transformation induced by the Lyapunov function for the system, and to build the ROM in the transformed variables. The result of this procedure will be a ROM that is energy-stablemore » for any choice of reduced basis. It is shown that, for many PDE systems, the desired transformation is induced by a special inner product, termed the “symmetry inner product”. Next, attention is turned to building energy-stable ROMs via discrete projection. A discrete counterpart of the continuous symmetry inner product, termed the “Lyapunov inner product”, is derived. Moreover, it is shown that the Lyapunov inner product can be computed in a black-box fashion for a stable LTI system ari sing from the discretization of a system of PDEs in space. Projection in this inner product guarantees a ROM that is energy-stable, again for any choice of reduced basis. Connections between the Lyapunov inner product and the inner product induced by the balanced truncation algorithm are made. We also made comparisons between the symmetry inner product and the Lyapunov inner product. Performance of ROMs constructed using these inner products is evaluated on several benchmark test cases.« less

  15. A Community Terrain-Following Ocean Modeling System (ROMS/TOMS)

    DTIC Science & Technology

    2011-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. A Community Terrain-Following Ocean Modeling System (ROMS...732) 932-6555 x266 Fax: (732) 932-6520 email: arango@marine.rutgers.edu Award Number: N00014-10- 1 -0322 http://ocean-modeling.org http...information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and

  16. Tidal simulation using regional ocean modeling systems (ROMS)

    NASA Technical Reports Server (NTRS)

    Wang, Xiaochun; Chao, Yi; Li, Zhijin; Dong, Changming; Farrara, John; McWilliams, James C.; Shum, C. K.; Wang, Yu; Matsumoto, Koji; Rosenfeld, Leslie K.; hide

    2006-01-01

    The purpose of our research is to test the capability of ROMS in simulating tides. The research also serves as a necessary exercise to implement tides in an operational ocean forecasting system. In this paper, we emphasize the validation of the model tide simulation. The characteristics and energetics of tides of the region will be reported in separate publications.

  17. Development and Utilization of Regional Oceanic Modeling System (ROMS). Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with the Regional Oceanic Modeling System (ROMS). Submesoscale Flows and Mixing in the Ocean Surface Layer Using the Regional Oceanic Modeling System (ROMS). Eddy Effects in General Circulation, Spanning Mean Currents, Mesoscale Eddies, and Topographic Generation, including Submesoscale Nests

    DTIC Science & Technology

    2012-09-30

    unbalanced motions is likely to occur. Due to an rapidly expanding set of investigation on oceanic flows at submesoscales, it is increasingly clear...Uchiyama, E. M. Lane, J. M. Restrepo, & J. C. McWilliams, 2011: A vortex force analysis of the interaction of rip currents and gravity waves. J. Geophys...particular topographic features, the torque is pervasively positive (cyclonic) along the Stream, in opposition to the anticyclonic wind curl in the

  18. Biomechanical comparison of effects of the Dynesys and Coflex dynamic stabilization systems on range of motion and loading characteristics in the lumbar spine: a finite element study.

    PubMed

    Kulduk, Ahmet; Altun, Necdet S; Senkoylu, Alpaslan

    2015-12-01

    The primary purpose of dynamic stabilization is to preserve the normal range of motion (ROM) by restricting abnormal movement in the spine. Our aim was to analyze the effects of two different dynamic stabilization systems using finite element modeling (FEM). Coflex and Dynesys dynamic devices were modeled and implanted at the L4-L5 segment using virtual FEM. A 400 N compressive force combined with 6 N flexion, extension, bending and axial rotation forces was applied to the L3-4 and L4-5 segments. ROM and disc loading forces were analyzed. Both systems reduced ROM and disc loading forces at the implanted lumbar segment, with the exception of the Coflex interspinous device, which increased ROM by 19% and did not change disc-loading forces in flexion. The Coflex device prevented excessive disc loading, but increased ROM abnormally in flexion. Neither device provided satisfactory motion preservation or load sharing in other directions. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Construction of energy-stable Galerkin reduced order models.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalashnikova, Irina; Barone, Matthew Franklin; Arunajatesan, Srinivasan

    2013-05-01

    This report aims to unify several approaches for building stable projection-based reduced order models (ROMs). Attention is focused on linear time-invariant (LTI) systems. The model reduction procedure consists of two steps: the computation of a reduced basis, and the projection of the governing partial differential equations (PDEs) onto this reduced basis. Two kinds of reduced bases are considered: the proper orthogonal decomposition (POD) basis and the balanced truncation basis. The projection step of the model reduction can be done in two ways: via continuous projection or via discrete projection. First, an approach for building energy-stable Galerkin ROMs for linear hyperbolicmore » or incompletely parabolic systems of PDEs using continuous projection is proposed. The idea is to apply to the set of PDEs a transformation induced by the Lyapunov function for the system, and to build the ROM in the transformed variables. The resulting ROM will be energy-stable for any choice of reduced basis. It is shown that, for many PDE systems, the desired transformation is induced by a special weighted L2 inner product, termed the %E2%80%9Csymmetry inner product%E2%80%9D. Attention is then turned to building energy-stable ROMs via discrete projection. A discrete counterpart of the continuous symmetry inner product, a weighted L2 inner product termed the %E2%80%9CLyapunov inner product%E2%80%9D, is derived. The weighting matrix that defines the Lyapunov inner product can be computed in a black-box fashion for a stable LTI system arising from the discretization of a system of PDEs in space. It is shown that a ROM constructed via discrete projection using the Lyapunov inner product will be energy-stable for any choice of reduced basis. Connections between the Lyapunov inner product and the inner product induced by the balanced truncation algorithm are made. Comparisons are also made between the symmetry inner product and the Lyapunov inner product. The performance of ROMs constructed using these inner products is evaluated on several benchmark test cases.« less

  20. Using the Model Coupling Toolkit to couple earth system models

    USGS Publications Warehouse

    Warner, J.C.; Perlin, N.; Skyllingstad, E.D.

    2008-01-01

    Continued advances in computational resources are providing the opportunity to operate more sophisticated numerical models. Additionally, there is an increasing demand for multidisciplinary studies that include interactions between different physical processes. Therefore there is a strong desire to develop coupled modeling systems that utilize existing models and allow efficient data exchange and model control. The basic system would entail model "1" running on "M" processors and model "2" running on "N" processors, with efficient exchange of model fields at predetermined synchronization intervals. Here we demonstrate two coupled systems: the coupling of the ocean circulation model Regional Ocean Modeling System (ROMS) to the surface wave model Simulating WAves Nearshore (SWAN), and the coupling of ROMS to the atmospheric model Coupled Ocean Atmosphere Prediction System (COAMPS). Both coupled systems use the Model Coupling Toolkit (MCT) as a mechanism for operation control and inter-model distributed memory transfer of model variables. In this paper we describe requirements and other options for model coupling, explain the MCT library, ROMS, SWAN and COAMPS models, methods for grid decomposition and sparse matrix interpolation, and provide an example from each coupled system. Methods presented in this paper are clearly applicable for coupling of other types of models. ?? 2008 Elsevier Ltd. All rights reserved.

  1. Reduced-Order Model for the Geochemical Impacts of Carbon Dioxide, Brine and Trace Metal Leakage into an Unconfined, Oxidizing Carbonate Aquifer, Version 2.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacon, Diana H.

    2013-03-31

    The National Risk Assessment Partnership (NRAP) consists of 5 U.S DOE national laboratories collaborating to develop a framework for predicting the risks associated with carbon sequestration. The approach taken by NRAP is to divide the system into components, including injection target reservoirs, wellbores, natural pathways including faults and fractures, groundwater and the atmosphere. Next, develop a detailed, physics and chemistry-based model of each component. Using the results of the detailed models, develop efficient, simplified models, termed reduced order models (ROM) for each component. Finally, integrate the component ROMs into a system model that calculates risk profiles for the site. Thismore » report details the development of the Groundwater Geochemistry ROM for the Edwards Aquifer at PNNL. The Groundwater Geochemistry ROM for the Edwards Aquifer uses a Wellbore Leakage ROM developed at LANL as input. The detailed model, using the STOMP simulator, covers a 5x8 km area of the Edwards Aquifer near San Antonio, Texas. The model includes heterogeneous hydraulic properties, and equilibrium, kinetic and sorption reactions between groundwater, leaked CO2 gas, brine, and the aquifer carbonate and clay minerals. Latin Hypercube sampling was used to generate 1024 samples of input parameters. For each of these input samples, the STOMP simulator was used to predict the flux of CO2 to the atmosphere, and the volume, length and width of the aquifer where pH was less than the MCL standard, and TDS, arsenic, cadmium and lead exceeded MCL standards. In order to decouple the Wellbore Leakage ROM from the Groundwater Geochemistry ROM, the response surface was transformed to replace Wellbore Leakage ROM input parameters with instantaneous and cumulative CO2 and brine leakage rates. The most sensitive parameters proved to be the CO2 and brine leakage rates from the well, with equilibrium coefficients for calcite and dolomite, as well as the number of illite and kaolinite sorption sites proving to be of secondary importance. The Groundwater Geochemistry ROM was developed using nonlinear regression to fit the response surface with a quadratic polynomial. The goodness of fit was excellent for the CO2 flux to the atmosphere, and very good for predicting the volumes of groundwater exceeding the pH, TDS, As, Cd and Pb threshold values.« less

  2. Reduced-order model for dynamic optimization of pressure swing adsorption processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, A.; Biegler, L.; Zitney, S.

    2007-01-01

    Over the past decades, pressure swing adsorption (PSA) processes have been widely used as energy-efficient gas and liquid separation techniques, especially for high purity hydrogen purification from refinery gases. The separation processes are based on solid-gas equilibrium and operate under periodic transient conditions. Models for PSA processes are therefore multiple instances of partial differential equations (PDEs) in time and space with periodic boundary conditions that link the processing steps together. The solution of this coupled stiff PDE system is governed by steep concentrations and temperature fronts moving with time. As a result, the optimization of such systems for either designmore » or operation represents a significant computational challenge to current differential algebraic equation (DAE) optimization techniques and nonlinear programming algorithms. Model reduction is one approach to generate cost-efficient low-order models which can be used as surrogate models in the optimization problems. The study develops a reduced-order model (ROM) based on proper orthogonal decomposition (POD), which is a low-dimensional approximation to a dynamic PDE-based model. Initially, a representative ensemble of solutions of the dynamic PDE system is constructed by solving a higher-order discretization of the model using the method of lines, a two-stage approach that discretizes the PDEs in space and then integrates the resulting DAEs over time. Next, the ROM method applies the Karhunen-Loeve expansion to derive a small set of empirical eigenfunctions (POD modes) which are used as basis functions within a Galerkin's projection framework to derive a low-order DAE system that accurately describes the dominant dynamics of the PDE system. The proposed method leads to a DAE system of significantly lower order, thus replacing the one obtained from spatial discretization before and making optimization problem computationally-efficient. The method has been applied to the dynamic coupled PDE-based model of a two-bed four-step PSA process for separation of hydrogen from methane. Separate ROMs have been developed for each operating step with different POD modes for each of them. A significant reduction in the order of the number of states has been achieved. The gas-phase mole fraction, solid-state loading and temperature profiles from the low-order ROM and from the high-order simulations have been compared. Moreover, the profiles for a different set of inputs and parameter values fed to the same ROM were compared with the accurate profiles from the high-order simulations. Current results indicate the proposed ROM methodology as a promising surrogate modeling technique for cost-effective optimization purposes. Moreover, deviations from the ROM for different set of inputs and parameters suggest that a recalibration of the model is required for the optimization studies. Results for these will also be presented with the aforementioned results.« less

  3. A Three-Dimensional Variational Data Assimilation Scheme for the Regional Ocean Modeling System: Implementation and Basic Experiments

    NASA Technical Reports Server (NTRS)

    Li, Zhijin; Chao, Yi; McWilliams, James C.; Ide, Kayo

    2008-01-01

    A three-dimensional variational data assimilation scheme for the Regional Ocean Modeling System (ROMS), named ROMS3DVAR, has been described in the work of Li et al. (2008). In this paper, ROMS3DVAR is applied to the central California coastal region, an area characterized by inhomogeneity and anisotropy, as well as by dynamically unbalanced flows. A method for estimating the model error variances from limited observations is presented, and the construction of the inhomogeneous and anisotropic error correlations based on the Kronecker product is demonstrated. A set of single observation experiments illustrates the inhomogeneous and anisotropic error correlations and weak dynamic constraints used. Results are presented from the assimilation of data gathered during the Autonomous Ocean Sampling Network (AOSN) experiment during August 2003. The results show that ROMS3DVAR is capable of reproducing complex flows associated with upwelling and relaxation, as well as the rapid transitions between them. Some difficulties encountered during the experiment are also discussed.

  4. Identification of Computational and Experimental Reduced-Order Models

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Hong, Moeljo S.; Bartels, Robert E.; Piatak, David J.; Scott, Robert C.

    2003-01-01

    The identification of computational and experimental reduced-order models (ROMs) for the analysis of unsteady aerodynamic responses and for efficient aeroelastic analyses is presented. For the identification of a computational aeroelastic ROM, the CFL3Dv6.0 computational fluid dynamics (CFD) code is used. Flutter results for the AGARD 445.6 Wing and for a Rigid Semispan Model (RSM) computed using CFL3Dv6.0 are presented, including discussion of associated computational costs. Modal impulse responses of the unsteady aerodynamic system are computed using the CFL3Dv6.0 code and transformed into state-space form. The unsteady aerodynamic state-space ROM is then combined with a state-space model of the structure to create an aeroelastic simulation using the MATLAB/SIMULINK environment. The MATLAB/SIMULINK ROM is then used to rapidly compute aeroelastic transients, including flutter. The ROM shows excellent agreement with the aeroelastic analyses computed using the CFL3Dv6.0 code directly. For the identification of experimental unsteady pressure ROMs, results are presented for two configurations: the RSM and a Benchmark Supercritical Wing (BSCW). Both models were used to acquire unsteady pressure data due to pitching oscillations on the Oscillating Turntable (OTT) system at the Transonic Dynamics Tunnel (TDT). A deconvolution scheme involving a step input in pitch and the resultant step response in pressure, for several pressure transducers, is used to identify the unsteady pressure impulse responses. The identified impulse responses are then used to predict the pressure responses due to pitching oscillations at several frequencies. Comparisons with the experimental data are then presented.

  5. Numerical model of the circulation and dispersion in the east Adriatic coastal waters

    NASA Astrophysics Data System (ADS)

    Beg Paklar, Gordana; Dzoic, Tomislav; Koracin, Darko; Matijevic, Slavica; Grbec, Branka; Ivatek-Sahdan, Stjepan

    2017-04-01

    The Regional Ocean Modeling System (ROMS) was implemented to reproduce physical properties of the area around submarine outlet Stobrec in the middle Adriatic coastal area. ROMS model run was forced with realistic atmospheric fields obtained from meteorological model Aladin, climatological river discharges, tides and dynamics of the surrounding area imposed at the open boundaries. Atmospheric forcing included momentum, heat and water fluxes calculated interactively from the Aladin surface fields during ROMS model simulations. Simulated fields from the Adriatic and shelf scale models were used to prescribe the initial and open boundary conditions for fine resolution coastal domain. Model results were compared with available CTD measurements and discussed in the light of the climatological circulation and thermohaline properties of the middle Adriatic coastal area. Variability in the circulation is related to the prevailing atmospheric conditions, changes in the hydrological conditions and water mass exchange at the open boundaries. Basic features of the coastal circulation are well reproduced by the ROMS model, as well as temperatures and salinities which are within corresponding seasonal intervals, although with lower stratification than measured ones. In order to reproduce dispersion of the passive tracer the ROMS model was coupled with Lagrangian dispersion model. Multiyear monitoring of the physical, chemical and biological parameters around the sewage outlet was used to assess the quality of the dispersion model results. Among measured parameters, redox potential of the surface sediment layer was selected to be compared with model results as its negative values are direct consequence of increased organic matter input that can be attributed to the sewage system inflow.

  6. Enforcing elemental mass and energy balances for reduced order models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, J.; Agarwal, K.; Sharma, P.

    2012-01-01

    Development of economically feasible gasification and carbon capture, utilization and storage (CCUS) technologies requires a variety of software tools to optimize the designs of not only the key devices involved (e., g., gasifier, CO{sub 2} adsorber) but also the entire power generation system. High-fidelity models such as Computational Fluid Dynamics (CFD) models are capable of accurately simulating the detailed flow dynamics, heat transfer, and chemistry inside the key devices. However, the integration of CFD models within steady-state process simulators, and subsequent optimization of the integrated system, still presents significant challenges due to the scale differences in both time and length,more » as well the high computational cost. A reduced order model (ROM) generated from a high-fidelity model can serve as a bridge between the models of different scales. While high-fidelity models are built upon the principles of mass, momentum, and energy conservations, ROMs are usually developed based on regression-type equations and hence their predictions may violate the mass and energy conservation laws. A high-fidelity model may also have the mass and energy balance problem if it is not tightly converged. Conservations of mass and energy are important when a ROM is integrated to a flowsheet for the process simulation of the entire chemical or power generation system, especially when recycle streams are connected to the modeled device. As a part of the Carbon Capture Simulation Initiative (CCSI) project supported by the U.S. Department of Energy, we developed a software framework for generating ROMs from CFD simulations and integrating them with Process Modeling Environments (PMEs) for system-wide optimization. This paper presents a method to correct the results of a high-fidelity model or a ROM such that the elemental mass and energy are conserved perfectly. Correction factors for the flow rates of individual species in the product streams are solved using a minimization algorithm based on Lagrangian multiplier method. Enthalpies of product streams are also modified to enforce the energy balance. The approach is illustrated for two ROMs, one based on a CFD model of an entrained-flow gasifier and the other based on the CFD model of a multiphase CO{sub 2} adsorber.« less

  7. Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with the Regional Oceanic Modeling System (ROMS)

    DTIC Science & Technology

    2013-09-30

    Geochemistry and Ecosystems: An important community use for ROMS is biogeochemisty: chemical cycles, water quality, blooms , micro-nutrients, larval...Sci., submitted. Colas, F., J.C. McWilliams, X. Capet, and J. Kurian, 2012: Heat balance and eddies in the Peru- Chile Current System. Climate

  8. Development of a Reduced-Order Model for Reacting Gas-Solids Flow using Proper Orthogonal Decomposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDaniel, Dwayne; Dulikravich, George; Cizmas, Paul

    2017-11-27

    This report summarizes the objectives, tasks and accomplishments made during the three year duration of this research project. The report presents the results obtained by applying advanced computational techniques to develop reduced-order models (ROMs) in the case of reacting multiphase flows based on high fidelity numerical simulation of gas-solids flow structures in risers and vertical columns obtained by the Multiphase Flow with Interphase eXchanges (MFIX) software. The research includes a numerical investigation of reacting and non-reacting gas-solids flow systems and computational analysis that will involve model development to accelerate the scale-up process for the design of fluidization systems by providingmore » accurate solutions that match the full-scale models. The computational work contributes to the development of a methodology for obtaining ROMs that is applicable to the system of gas-solid flows. Finally, the validity of the developed ROMs is evaluated by comparing the results against those obtained using the MFIX code. Additionally, the robustness of existing POD-based ROMs for multiphase flows is improved by avoiding non-physical solutions of the gas void fraction and ensuring that the reduced kinetics models used for reactive flows in fluidized beds are thermodynamically consistent.« less

  9. Computer aided systems human engineering: A hypermedia tool

    NASA Technical Reports Server (NTRS)

    Boff, Kenneth R.; Monk, Donald L.; Cody, William J.

    1992-01-01

    The Computer Aided Systems Human Engineering (CASHE) system, Version 1.0, is a multimedia ergonomics database on CD-ROM for the Apple Macintosh II computer, being developed for use by human system designers, educators, and researchers. It will initially be available on CD-ROM and will allow users to access ergonomics data and models stored electronically as text, graphics, and audio. The CASHE CD-ROM, Version 1.0 will contain the Boff and Lincoln (1988) Engineering Data Compendium, MIL-STD-1472D and a unique, interactive simulation capability, the Perception and Performance Prototyper. Its features also include a specialized data retrieval, scaling, and analysis capability and the state of the art in information retrieval, browsing, and navigation.

  10. Constrained reduced-order models based on proper orthogonal decomposition

    DOE PAGES

    Reddy, Sohail R.; Freno, Brian Andrew; Cizmas, Paul G. A.; ...

    2017-04-09

    A novel approach is presented to constrain reduced-order models (ROM) based on proper orthogonal decomposition (POD). The Karush–Kuhn–Tucker (KKT) conditions were applied to the traditional reduced-order model to constrain the solution to user-defined bounds. The constrained reduced-order model (C-ROM) was applied and validated against the analytical solution to the first-order wave equation. C-ROM was also applied to the analysis of fluidized beds. Lastly, it was shown that the ROM and C-ROM produced accurate results and that C-ROM was less sensitive to error propagation through time than the ROM.

  11. Reduced-Order Model for Leakage Through an Open Wellbore from the Reservoir due to Carbon Dioxide Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Lehua; Oldenburg, Curtis M.

    Potential CO 2 leakage through existing open wellbores is one of the most significant hazards that need to be addressed in geologic carbon sequestration (GCS) projects. In the framework of the National Risk Assessment Partnership (NRAP) which requires fast computations for uncertainty analysis, rigorous simulation of the coupled wellbore-reservoir system is not practical. We have developed a 7,200-point look-up table reduced-order model (ROM) for estimating the potential leakage rate up open wellbores in response to CO 2 injection nearby. The ROM is based on coupled simulations using T2Well/ECO2H which was run repeatedly for representative conditions relevant to NRAP to createmore » a look-up table response-surface ROM. The ROM applies to a wellbore that fully penetrates a 20-m thick reservoir that is used for CO 2 storage. The radially symmetric reservoir is assumed to have initially uniform pressure, temperature, gas saturation, and brine salinity, and it is assumed these conditions are held constant at the far-field boundary (100 m away from the wellbore). In such a system, the leakage can quickly reach quasi-steady state. The ROM table can be used to estimate both the free-phase CO 2 and brine leakage rates through an open well as a function of wellbore and reservoir conditions. Results show that injection-induced pressure and reservoir gas saturation play important roles in controlling leakage. Caution must be used in the application of this ROM because well leakage is formally transient and the ROM lookup table was populated using quasi-steady simulation output after 1000 time steps which may correspond to different physical times for the various parameter combinations of the coupled wellbore-reservoir system.« less

  12. Real-time solution of linear computational problems using databases of parametric reduced-order models with arbitrary underlying meshes

    NASA Astrophysics Data System (ADS)

    Amsallem, David; Tezaur, Radek; Farhat, Charbel

    2016-12-01

    A comprehensive approach for real-time computations using a database of parametric, linear, projection-based reduced-order models (ROMs) based on arbitrary underlying meshes is proposed. In the offline phase of this approach, the parameter space is sampled and linear ROMs defined by linear reduced operators are pre-computed at the sampled parameter points and stored. Then, these operators and associated ROMs are transformed into counterparts that satisfy a certain notion of consistency. In the online phase of this approach, a linear ROM is constructed in real-time at a queried but unsampled parameter point by interpolating the pre-computed linear reduced operators on matrix manifolds and therefore computing an interpolated linear ROM. The proposed overall model reduction framework is illustrated with two applications: a parametric inverse acoustic scattering problem associated with a mockup submarine, and a parametric flutter prediction problem associated with a wing-tank system. The second application is implemented on a mobile device, illustrating the capability of the proposed computational framework to operate in real-time.

  13. Oceanic response to tropical cyclone `Phailin' in the Bay of Bengal

    NASA Astrophysics Data System (ADS)

    Pant, V.; Prakash, K. R.

    2016-02-01

    Vertical mixing largely explains surface cooling induced by Tropical Cyclones (TCs). However, TC-induced upwelling of deeper waters plays an important role as it partly balances the warming of subsurface waters induced by vertical mixing. Below 100 m, vertical advection results in cooling that persists for a few days after the storm. The present study investigates the integrated ocean response to tropical cyclone `Phaillin' (10-14 October 2013) in the Bay of Bengal (BoB) through both coupled and stand-alone ocean-atmosphere models. Two numerical experiments with different coupling configurations between Regional Ocean Modelling System (ROMS) and Weather Research and Forecasting (WRF) were performed to investigate the impact of Phailin cyclone on the surface and sub-surface oceanic parameters. In the first experiment, ocean circulation model ROMS observe surface wind forcing from a mesoscale atmospheric model (WRF with nested damin setup), while rest forcing parameters are supplied to ROMS from NCEP data. In the second experiment, all surface forcing data to ROMS directly comes from WRF. The modeling components and data fields exchanged between atmospheric and oceanic models are described. The coupled modeling system is used to identify model sensitivity by exchanging prognostic variable fields between the two model components during simulation of Phallin cyclone (10-14 October 2013) in the BoB.In general, the simulated Phailin cyclone track and intensities agree well with observations in WRF simulations. Further, the inter-comparison between stand-alone and coupled model simulations validated against observations highlights better performance of coupled modeling system in simulating the oceanic conditions during the Phailin cyclone event.

  14. A data-assimilative ocean forecasting system for the Prince William sound and an evaluation of its performance during sound Predictions 2009

    NASA Astrophysics Data System (ADS)

    Farrara, John D.; Chao, Yi; Li, Zhijin; Wang, Xiaochun; Jin, Xin; Zhang, Hongchun; Li, Peggy; Vu, Quoc; Olsson, Peter Q.; Schoch, G. Carl; Halverson, Mark; Moline, Mark A.; Ohlmann, Carter; Johnson, Mark; McWilliams, James C.; Colas, Francois A.

    2013-07-01

    The development and implementation of a three-dimensional ocean modeling system for the Prince William Sound (PWS) is described. The system consists of a regional ocean model component (ROMS) forced by output from a regional atmospheric model component (the Weather Research and Forecasting Model, WRF). The ROMS ocean model component has a horizontal resolution of 1km within PWS and utilizes a recently-developed multi-scale 3DVAR data assimilation methodology along with freshwater runoff from land obtained via real-time execution of a digital elevation model. During the Sound Predictions Field Experiment (July 19-August 3, 2009) the system was run in real-time to support operations and incorporated all available real-time streams of data. Nowcasts were produced every 6h and a 48-h forecast was performed once a day. In addition, a sixteen-member ensemble of forecasts was executed on most days. All results were published at a web portal (http://ourocean.jpl.nasa.gov/PWS) in real time to support decision making.The performance of the system during Sound Predictions 2009 is evaluated. The ROMS results are first compared with the assimilated data as a consistency check. RMS differences of about 0.7°C were found between the ROMS temperatures and the observed vertical profiles of temperature that are assimilated. The ROMS salinities show greater discrepancies, tending to be too salty near the surface. The overall circulation patterns observed throughout the Sound are qualitatively reproduced, including the following evolution in time. During the first week of the experiment, the weather was quite stormy with strong southeasterly winds. This resulted in strong north to northwestward surface flow in much of the central PWS. Both the observed drifter trajectories and the ROMS nowcasts showed strong surface inflow into the Sound through the Hinchinbrook Entrance and strong generally northward to northwestward flow in the central Sound that was exiting through the Knight Island Passage and Montague Strait entrance. During the latter part of the second week when surface winds were light and southwesterly, the mean surface flow at the Hinchinbrook Entrance reversed to weak outflow and a cyclonic eddy formed in the central Sound. Overall, RMS differences between ROMS surface currents and observed HF radar surface currents in the central Sound were generally between 5 and 10cm/s, about 20-40% of the time mean current speeds.The ROMS reanalysis is then validated against independent observations. A comparison of the ROMS currents with observed vertical current profiles from moored ADCPs in the Hinchinbrook Entrance and Montague Strait shows good qualitative agreement and confirms the evolution of the near surface inflow/outflow at these locations described above. A comparison of the ROMS surface currents with drifter trajectories provided additional confirmation that the evolution of the surface flow described above was realistic. Forecasts of drifter locations had RMS errors of less than 10km for up to 36h. One and two-day forecasts of surface temperature, salinity and current fields were more skillful than persistence forecasts. In addition, ensemble mean forecasts were found to be slightly more skillful than single forecasts. Two case studies demonstrated the system's qualitative skill in predicting subsurface changes within the mixed layer measured by ships and autonomous underwater vehicles. In summary, the system is capable of producing a realistic evolution of the near-surface circulation within PWS including forecasts of up to two days of this evolution. Use of the products provided by the system during the experiment as part of the asset deployment decision making process demonstrated the value of accurate regional ocean forecasts in support of field experiments.

  15. Development of Unsteady Aerodynamic and Aeroelastic Reduced-Order Models Using the FUN3D Code

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Vatsa, Veer N.; Biedron, Robert T.

    2009-01-01

    Recent significant improvements to the development of CFD-based unsteady aerodynamic reduced-order models (ROMs) are implemented into the FUN3D unstructured flow solver. These improvements include the simultaneous excitation of the structural modes of the CFD-based unsteady aerodynamic system via a single CFD solution, minimization of the error between the full CFD and the ROM unsteady aero- dynamic solution, and computation of a root locus plot of the aeroelastic ROM. Results are presented for a viscous version of the two-dimensional Benchmark Active Controls Technology (BACT) model and an inviscid version of the AGARD 445.6 aeroelastic wing using the FUN3D code.

  16. Implementation of the US EPA (United States Environmental Protection Agency) Regional Oxidant Modeling System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Novak, J.H.

    1984-05-01

    Model design, implementation and quality assurance procedures can have a significant impact on the effectiveness of long term utility of any modeling approach. The Regional Oxidant Modeling System (ROMS) is exceptionally complex because it treats all chemical and physical processes thought to affect ozone concentration on a regional scale. Thus, to effectively illustrate useful design and implementation techniques, this paper describes the general modeling framework which forms the basis of the ROMS. This framework is flexible enough to allow straightforward update or replacement of the chemical kinetics mechanism and/or any theoretical formulations of the physical processes. Use of the Jacksonmore » Structured Programming (JSP) method to implement this modeling framework has not only increased programmer productivity and quality of the resulting programs, but also has provided standardized program design, dynamic documentation, and easily maintainable and transportable code. A summary of the JSP method is presented to encourage modelers to pursue this technique in their own model development efforts. In addition, since data preparation is such an integral part of a successful modeling system, the ROMS processor network is described with emphasis on the internal quality control techniques.« less

  17. Reduced order models for prediction of groundwater quality impacts from CO₂ and brine leakage

    DOE PAGES

    Zheng, Liange; Carroll, Susan; Bianchi, Marco; ...

    2014-12-31

    A careful assessment of the risk associated with geologic CO₂ storage is critical to the deployment of large-scale storage projects. A potential risk is the deterioration of groundwater quality caused by the leakage of CO₂ and brine leakage from deep subsurface reservoirs. In probabilistic risk assessment studies, numerical modeling is the primary tool employed to assess risk. However, the application of traditional numerical models to fully evaluate the impact of CO₂ leakage on groundwater can be computationally complex, demanding large processing times and resources, and involving large uncertainties. As an alternative, reduced order models (ROMs) can be used as highlymore » efficient surrogates for the complex process-based numerical models. In this study, we represent the complex hydrogeological and geochemical conditions in a heterogeneous aquifer and subsequent risk by developing and using two separate ROMs. The first ROM is derived from a model that accounts for the heterogeneous flow and transport conditions in the presence of complex leakage functions for CO₂ and brine. The second ROM is obtained from models that feature similar, but simplified flow and transport conditions, and allow for a more complex representation of all relevant geochemical reactions. To quantify possible impacts to groundwater aquifers, the basic risk metric is taken as the aquifer volume in which the water quality of the aquifer may be affected by an underlying CO₂ storage project. The integration of the two ROMs provides an estimate of the impacted aquifer volume taking into account uncertainties in flow, transport and chemical conditions. These two ROMs can be linked in a comprehensive system level model for quantitative risk assessment of the deep storage reservoir, wellbore leakage, and shallow aquifer impacts to assess the collective risk of CO₂ storage projects.« less

  18. Breaking Computational Barriers: Real-time Analysis and Optimization with Large-scale Nonlinear Models via Model Reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlberg, Kevin Thomas; Drohmann, Martin; Tuminaro, Raymond S.

    2014-10-01

    Model reduction for dynamical systems is a promising approach for reducing the computational cost of large-scale physics-based simulations to enable high-fidelity models to be used in many- query (e.g., Bayesian inference) and near-real-time (e.g., fast-turnaround simulation) contexts. While model reduction works well for specialized problems such as linear time-invariant systems, it is much more difficult to obtain accurate, stable, and efficient reduced-order models (ROMs) for systems with general nonlinearities. This report describes several advances that enable nonlinear reduced-order models (ROMs) to be deployed in a variety of time-critical settings. First, we present an error bound for the Gauss-Newton with Approximatedmore » Tensors (GNAT) nonlinear model reduction technique. This bound allows the state-space error for the GNAT method to be quantified when applied with the backward Euler time-integration scheme. Second, we present a methodology for preserving classical Lagrangian structure in nonlinear model reduction. This technique guarantees that important properties--such as energy conservation and symplectic time-evolution maps--are preserved when performing model reduction for models described by a Lagrangian formalism (e.g., molecular dynamics, structural dynamics). Third, we present a novel technique for decreasing the temporal complexity --defined as the number of Newton-like iterations performed over the course of the simulation--by exploiting time-domain data. Fourth, we describe a novel method for refining projection-based reduced-order models a posteriori using a goal-oriented framework similar to mesh-adaptive h -refinement in finite elements. The technique allows the ROM to generate arbitrarily accurate solutions, thereby providing the ROM with a 'failsafe' mechanism in the event of insufficient training data. Finally, we present the reduced-order model error surrogate (ROMES) method for statistically quantifying reduced- order-model errors. This enables ROMs to be rigorously incorporated in uncertainty-quantification settings, as the error model can be treated as a source of epistemic uncertainty. This work was completed as part of a Truman Fellowship appointment. We note that much additional work was performed as part of the Fellowship. One salient project is the development of the Trilinos-based model-reduction software module Razor , which is currently bundled with the Albany PDE code and currently allows nonlinear reduced-order models to be constructed for any application supported in Albany. Other important projects include the following: 1. ROMES-equipped ROMs for Bayesian inference: K. Carlberg, M. Drohmann, F. Lu (Lawrence Berkeley National Laboratory), M. Morzfeld (Lawrence Berkeley National Laboratory). 2. ROM-enabled Krylov-subspace recycling: K. Carlberg, V. Forstall (University of Maryland), P. Tsuji, R. Tuminaro. 3. A pseudo balanced POD method using only dual snapshots: K. Carlberg, M. Sarovar. 4. An analysis of discrete v. continuous optimality in nonlinear model reduction: K. Carlberg, M. Barone, H. Antil (George Mason University). Journal articles for these projects are in progress at the time of this writing.« less

  19. CCSI and the role of advanced computing in accelerating the commercial deployment of carbon capture systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David; Agarwal, Deborah A.; Sun, Xin

    2011-09-01

    The Carbon Capture Simulation Initiative is developing state-of-the-art computational modeling and simulation tools to accelerate the commercialization of carbon capture technology. The CCSI Toolset consists of an integrated multi-scale modeling and simulation framework, which includes extensive use of reduced order models (ROMs) and a comprehensive uncertainty quantification (UQ) methodology. This paper focuses on the interrelation among high performance computing, detailed device simulations, ROMs for scale-bridging, UQ and the integration framework.

  20. CCSI and the role of advanced computing in accelerating the commercial deployment of carbon capture systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Agarwal, D.; Sun, X.

    2011-01-01

    The Carbon Capture Simulation Initiative is developing state-of-the-art computational modeling and simulation tools to accelerate the commercialization of carbon capture technology. The CCSI Toolset consists of an integrated multi-scale modeling and simulation framework, which includes extensive use of reduced order models (ROMs) and a comprehensive uncertainty quantification (UQ) methodology. This paper focuses on the interrelation among high performance computing, detailed device simulations, ROMs for scale-bridging, UQ and the integration framework.

  1. Validation of the All Patient Refined Diagnosis Related Group (APR-DRG) Risk of Mortality and Severity of Illness Modifiers as a Measure of Perioperative Risk.

    PubMed

    McCormick, Patrick J; Lin, Hung-Mo; Deiner, Stacie G; Levin, Matthew A

    2018-03-22

    The All Patient Refined Diagnosis Related Group (APR-DRG) is an inpatient visit classification system that assigns a diagnostic related group, a Risk of Mortality (ROM) subclass and a Severity of Illness (SOI) subclass. While extensively used for cost adjustment, no study has compared the APR-DRG subclass modifiers to the popular Charlson Comorbidity Index as a measure of comorbidity severity in models for perioperative in-hospital mortality. In this study we attempt to validate the use of these subclasses to predict mortality in a cohort of surgical patients. We analyzed all adult (age over 18 years) inpatient non-cardiac surgery at our institution between December 2005 and July 2013. After exclusions, we split the cohort into training and validation sets. We created prediction models of inpatient mortality using the Charlson Comorbidity Index, ROM only, SOI only, and ROM with SOI. Models were compared by receiver-operator characteristic (ROC) curve, area under the ROC curve (AUC), and Brier score. After exclusions, we analyzed 63,681 patient-visits. Overall in-hospital mortality was 1.3%. The median number of ICD-9-CM diagnosis codes was 6 (Q1-Q3 4-10). The median Charlson Comorbidity Index was 0 (Q1-Q3 0-2). When the model was applied to the validation set, the c-statistic for Charlson was 0.865, c-statistic for ROM was 0.975, and for ROM and SOI combined the c-statistic was 0.977. The scaled Brier score for Charlson was 0.044, Brier for ROM only was 0.230, and Brier for ROM and SOI was 0.257. The APR-DRG ROM or SOI subclasses are better predictors than the Charlson Comorbidity Index of in-hospital mortality among surgical patients.

  2. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Shimbori, Susumu

    CD-ROM has recently attracted remarkable attentions as a new information media. In this feature the following points concerning CD-ROM are described: (1) Development of CD-ROM from audio CD, (2)advantages and character of CD-ROM compared with printed or online media, (3)CD-ROM specification by Philips-Sony, (4)hardware and system construction with CD-ROM, and (5)production processes of CD-ROM.

  3. Genetic Algorithm-Guided, Adaptive Model Order Reduction of Flexible Aircrafts

    NASA Technical Reports Server (NTRS)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter; Brenner, Martin J.

    2017-01-01

    This paper presents a methodology for automated model order reduction (MOR) of flexible aircrafts to construct linear parameter-varying (LPV) reduced order models (ROM) for aeroservoelasticity (ASE) analysis and control synthesis in broad flight parameter space. The novelty includes utilization of genetic algorithms (GAs) to automatically determine the states for reduction while minimizing the trial-and-error process and heuristics requirement to perform MOR; balanced truncation for unstable systems to achieve locally optimal realization of the full model; congruence transformation for "weak" fulfillment of state consistency across the entire flight parameter space; and ROM interpolation based on adaptive grid refinement to generate a globally functional LPV ASE ROM. The methodology is applied to the X-56A MUTT model currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that X-56A ROM with less than one-seventh the number of states relative to the original model is able to accurately predict system response among all input-output channels for pitch, roll, and ASE control at various flight conditions. The GA-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The adaptive refinement allows selective addition of the grid points in the parameter space where flight dynamics varies dramatically to enhance interpolation accuracy without over-burdening controller synthesis and onboard memory efforts downstream. The present MOR framework can be used by control engineers for robust ASE controller synthesis and novel vehicle design.

  4. CAI System of Obunsha Co., Ltd. Using CD-ROM

    NASA Astrophysics Data System (ADS)

    Todokoro, Shigeru; Mukai, Yoshihiro

    This paper introduces the present status of R & D on CAI teaching materials in Obunsha Co., Ltd. Characteristics of CAI using CD-ROM as well as Culture-in CAI Teaching Materials System for junior high school English are described. The system consists of CD-ROM driver XM-2000 and Pasopia 700 of Toshiba Corporation having both features of CD-ROM and FD. CD-ROM stores vast amount of voice data while FD does text and graphics data. It is a frame-oriented mode system enabling to raise learning effect.

  5. Cohesive and mixed sediment in the Regional Ocean Modeling System (ROMS v3.6) implemented in the Coupled Ocean-Atmosphere-Wave-Sediment Transport Modeling System (COAWST r1234)

    NASA Astrophysics Data System (ADS)

    Sherwood, Christopher R.; Aretxabaleta, Alfredo L.; Harris, Courtney K.; Rinehimer, J. Paul; Verney, Romaric; Ferré, Bénédicte

    2018-05-01

    We describe and demonstrate algorithms for treating cohesive and mixed sediment that have been added to the Regional Ocean Modeling System (ROMS version 3.6), as implemented in the Coupled Ocean-Atmosphere-Wave-Sediment Transport Modeling System (COAWST Subversion repository revision 1234). These include the following: floc dynamics (aggregation and disaggregation in the water column); changes in floc characteristics in the seabed; erosion and deposition of cohesive and mixed (combination of cohesive and non-cohesive) sediment; and biodiffusive mixing of bed sediment. These routines supplement existing non-cohesive sediment modules, thereby increasing our ability to model fine-grained and mixed-sediment environments. Additionally, we describe changes to the sediment bed layering scheme that improve the fidelity of the modeled stratigraphic record. Finally, we provide examples of these modules implemented in idealized test cases and a realistic application.

  6. Model Order Reduction of Aeroservoelastic Model of Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Wang, Yi; Song, Hongjun; Pant, Kapil; Brenner, Martin J.; Suh, Peter

    2016-01-01

    This paper presents a holistic model order reduction (MOR) methodology and framework that integrates key technological elements of sequential model reduction, consistent model representation, and model interpolation for constructing high-quality linear parameter-varying (LPV) aeroservoelastic (ASE) reduced order models (ROMs) of flexible aircraft. The sequential MOR encapsulates a suite of reduction techniques, such as truncation and residualization, modal reduction, and balanced realization and truncation to achieve optimal ROMs at grid points across the flight envelope. The consistence in state representation among local ROMs is obtained by the novel method of common subspace reprojection. Model interpolation is then exploited to stitch ROMs at grid points to build a global LPV ASE ROM feasible to arbitrary flight condition. The MOR method is applied to the X-56A MUTT vehicle with flexible wing being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies demonstrated that relative to the fullorder model, our X-56A ROM can accurately and reliably capture vehicles dynamics at various flight conditions in the target frequency regime while the number of states in ROM can be reduced by 10X (from 180 to 19), and hence, holds great promise for robust ASE controller synthesis and novel vehicle design.

  7. Special Considerations for Networking Multimedia CD-ROM Titles.

    ERIC Educational Resources Information Center

    Wolfe, Janet L.

    1994-01-01

    Discusses issues to be considered when networking multimedia CD-ROMs. Topics addressed include CD-ROM networking software; license concerns; configurations for CD-ROM servers; data caching; SCSI devices; CD-ROM drives; workstation configurations, including minimum requirements for five popular CD-ROM titles; and system setup troubleshooting tips.…

  8. Reduced order modeling, statistical analysis and system identification for a bladed rotor with geometric mistuning

    NASA Astrophysics Data System (ADS)

    Vishwakarma, Vinod

    Modified Modal Domain Analysis (MMDA) is a novel method for the development of a reduced-order model (ROM) of a bladed rotor. This method utilizes proper orthogonal decomposition (POD) of Coordinate Measurement Machine (CMM) data of blades' geometries and sector analyses using ANSYS. For the first time ROM of a geometrically mistuned industrial scale rotor (Transonic rotor) with large size of Finite Element (FE) model is generated using MMDA. Two methods for estimating mass and stiffness mistuning matrices are used a) exact computation from sector FE analysis, b) estimates based on POD mistuning parameters. Modal characteristics such as mistuned natural frequencies, mode shapes and forced harmonic response are obtained from ROM for various cases, and results are compared with full rotor ANSYS analysis and other ROM methods such as Subset of Nominal Modes (SNM) and Fundamental Model of Mistuning (FMM). Accuracy of MMDA ROM is demonstrated with variations in number of POD features and geometric mistuning parameters. It is shown for the aforementioned case b) that the high accuracy of ROM studied in previous work with Academic rotor does not directly translate to the Transonic rotor. Reasons for such mismatch in results are investigated and attributed to higher mistuning in Transonic rotor. Alternate solutions such as estimation of sensitivities via least squares, and interpolation of mass and stiffness matrices on manifolds are developed, and their results are discussed. Statistics such as mean and standard deviations of forced harmonic response peak amplitude are obtained from random permutations, and are shown to have similar results as those of Monte Carlo simulations. These statistics are obtained and compared for 3 degree of freedom (DOF) lumped parameter model (LPM) of rotor, Academic rotor and Transonic rotor. A state -- estimator based on MMDA ROM and Kalman filter is also developed for offline or online estimation of harmonic forcing function from measurements of forced response. Forcing function is estimated for synchronous excitation of 3DOF rotor model, Academic rotor and Transonic rotor from measurement of response at few nodes. For asynchronous excitation forcing function is estimated only for 3DOF rotor model and Academic rotor from measurement of response. The impact of number of measurement locations and accuracy of ROM on the estimation of forcing function is discussed. iv.

  9. Biomechanical analysis of a new lumbar interspinous device with optimized topology.

    PubMed

    Chen, Chen-Sheng; Shih, Shih-Liang

    2018-01-06

    Interspinous spacers used stand-alone preserve joint movement but provide little protection for diseased segments of the spine. Used as adjuncts with fusion, interspinous spacers offer rigid stability but may accelerate degeneration on adjacent levels. Our new device is intended to balance the stability and preserves motion provided by the implant. A new interspinous spacer was devised according to the results of topology optimization studies. Four finite element (FE) spine models were created that consisted of an intact spine without an implant, implantation of the novel, the device for intervertebral assisted motion (DIAM system), and the Dynesys system. All models were loaded with moments, and their range of motions (ROMs), peak disc stresses, and facet contact forces were analyzed. The limited motion segment ROMs, shielded disc stresses, and unloaded facet contact forces of the new devices were greater than those of the DIAM and Dynesys system at L3-L4 in almost all directions of movements. The ROMs, disc stresses, and facet contact forces of the new devices at L2-L3 were slightly greater than those in the DIAM system, but much lower than those in the Dynesys system in most directions. This study demonstrated that the new device provided more stability at the instrumented level than the DIAM system did, especially in lateral rotation and the bending direction. The device caused fewer adjacent ROMs, lower disc stresses, and lower facet contact forces than the Dynesys system did. Additionally, this study conducted topology optimization to design the new device and created a smaller implant for minimal invasive surgery.

  10. Investigation of the Stability of POD-Galerkin Techniques for Reduced Order Model Development

    DTIC Science & Technology

    2016-01-09

    symmetrizing the higher- order PDE with a preconditioning matrix. Rowley et al. also pointed out that defining a proper inner product can be important when...equations. The ROM is obtained by employing Galerkin’s method to reduce the high-order PDEs to a lower-order ODE system by means of POD eigen-bases...employing Galerkin’s method to reduce the high-order PDEs to a lower-order ODE system by means of POD eigen-bases. Possible solutions of the ROM stability

  11. Generalized Reduced Order Modeling of Aeroservoelastic Systems

    NASA Astrophysics Data System (ADS)

    Gariffo, James Michael

    Transonic aeroelastic and aeroservoelastic (ASE) modeling presents a significant technical and computational challenge. Flow fields with a mixture of subsonic and supersonic flow, as well as moving shock waves, can only be captured through high-fidelity CFD analysis. With modern computing power, it is realtively straightforward to determine the flutter boundary for a single structural configuration at a single flight condition, but problems of larger scope remain quite costly. Some such problems include characterizing a vehicle's flutter boundary over its full flight envelope, optimizing its structural weight subject to aeroelastic constraints, and designing control laws for flutter suppression. For all of these applications, reduced-order models (ROMs) offer substantial computational savings. ROM techniques in general have existed for decades, and the methodology presented in this dissertation builds on successful previous techniques to create a powerful new scheme for modeling aeroelastic systems, and predicting and interpolating their transonic flutter boundaries. In this method, linear ASE state-space models are constructed from modal structural and actuator models coupled to state-space models of the linearized aerodynamic forces through feedback loops. Flutter predictions can be made from these models through simple eigenvalue analysis of their state-transition matrices for an appropriate set of dynamic pressures. Moreover, this analysis returns the frequency and damping trend of every aeroelastic branch. In contrast, determining the critical dynamic pressure by direct time-marching CFD requires a separate run for every dynamic pressure being analyzed simply to obtain the trend for the critical branch. The present ROM methodology also includes a new model interpolation technique that greatly enhances the benefits of these ROMs. This enables predictions of the dynamic behavior of the system for flight conditions where CFD analysis has not been explicitly performed, thus making it possible to characterize the overall flutter boundary with far fewer CFD runs. A major challenge of this research is that transonic flutter boundaries can involve multiple unstable modes of different types. Multiple ROM-based studies on the ONERA M6 wing are shown indicating that in addition to classic bending-torsion (BT) flutter modes. which become unstable above a threshold dynamic pressure after two natural modes become aerodynamically coupled, some natural modes are able to extract energy from the air and become unstable by themselves. These single-mode instabilities tend to be weaker than the BT instabilities, but have near-zero flutter boundaries (exactly zero in the absence of structural damping). Examples of hump modes, which behave like natural mode instabilities before stabilizing, are also shown, as are cases where multiple instabilities coexist at a single flight condition. The result of all these instabilities is a highly sensitive flutter boundary, where small changes in Mach number, structural stiffness, and structural damping can substantially alter not only the stability of individual aeroelastic branches, but also which branch is critical. Several studies are shown presenting how the flutter boundary varies with respect to all three of these parameters, as well as the number of structural modes used to construct the ROMs. Finally, an investigation of the effectiveness and limitations of the interpolation scheme is presented. It is found that in regions where the flutter boundary is relatively smooth, the interpolation method produces ROMs that predict the flutter characteristics of the corresponding directly computed models to a high degree of accuracy, even for relatively coarsely spaced data. On the other hand, in the transonic dip region, the interpolated ROMs show significant errors at points where the boundary changes rapidly; however, they still give a good qualitative estimate of where the largest jumps occur.

  12. EPA EXPOSURE MODELS LIBRARY AND INTEGRATED MODEL EVALUATION SYSTEM

    EPA Science Inventory

    The third edition of the U.S. Environmental Protection Agencys (EPA) EML/IMES (Exposure Models Library and Integrated Model Evaluation System) on CD-ROM is now available. The purpose of the disc is to provide a compact and efficient means to distribute exposure models, documentat...

  13. A Generalized Framework for Reduced-Order Modeling of a Wind Turbine Wake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, Nicholas; Viggiano, Bianca; Calaf, Marc

    A reduced-order model for a wind turbine wake is sought from large eddy simulation data. Fluctuating velocity fields are combined in the correlation tensor to form the kernel of the proper orthogonal decomposition (POD). Proper orthogonal decomposition modes resulting from the decomposition represent the spatially coherent turbulence structures in the wind turbine wake; eigenvalues delineate the relative amount of turbulent kinetic energy associated with each mode. Back-projecting the POD modes onto the velocity snapshots produces dynamic coefficients that express the amplitude of each mode in time. A reduced-order model of the wind turbine wake (wakeROM) is defined through a seriesmore » of polynomial parameters that quantify mode interaction and the evolution of each POD mode coefficients. The resulting system of ordinary differential equations models the wind turbine wake composed only of the large-scale turbulent dynamics identified by the POD. Tikhonov regularization is used to recalibrate the dynamical system by adding additional constraints to the minimization seeking polynomial parameters, reducing error in the modeled mode coefficients. The wakeROM is periodically reinitialized with new initial conditions found by relating the incoming turbulent velocity to the POD mode coefficients through a series of open-loop transfer functions. The wakeROM reproduces mode coefficients to within 25.2%, quantified through the normalized root-mean-square error. A high-level view of the modeling approach is provided as a platform to discuss promising research directions, alternate processes that could benefit stability and efficiency, and desired extensions of the wakeROM.« less

  14. A trust-region algorithm for the optimization of PSA processes using reduced-order modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, A.; Biegler, L.; Zitney, S.

    2009-01-01

    The last few decades have seen a considerable increase in the applications of adsorptive gas separation technologies, such as pressure swing adsorption (PSA); the applications range from bulk separations to trace contaminant removal. PSA processes are based on solid-gas equilibrium and operate under periodic transient conditions [1]. Bed models for these processes are therefore defined by coupled nonlinear partial differential and algebraic equations (PDAEs) distributed in space and time with periodic boundary conditions that connect the processing steps together and high nonlinearities arising from non-isothermal effects and nonlinear adsorption isotherms. As a result, the optimization of such systems for eithermore » design or operation represents a significant computational challenge to current nonlinear programming algorithms. Model reduction is a powerful methodology that permits systematic generation of cost-efficient low-order representations of large-scale systems that result from discretization of such PDAEs. In particular, low-dimensional approximations can be obtained from reduced order modeling (ROM) techniques based on proper orthogonal decomposition (POD) and can be used as surrogate models in the optimization problems. In this approach, a representative ensemble of solutions of the dynamic PDAE system is constructed by solving a higher-order discretization of the model using the method of lines, followed by the application of Karhunen-Loeve expansion to derive a small set of empirical eigenfunctions (POD modes). These modes are used as basis functions within a Galerkin's projection framework to derive a low-order DAE system that accurately describes the dominant dynamics of the PDAE system. This approach leads to a DAE system of significantly lower order, thus replacing the one obtained from spatial discretization before and making optimization problem computationally efficient [2]. The ROM methodology has been successfully applied to a 2-bed 4-step PSA process used for separating a hydrogen-methane mixture in [3]. The reduced order model developed was successfully used to optimize this process to maximize hydrogen recovery within a trust-region. We extend this approach in this work to develop a rigorous trust-region algorithm for ROM-based optimization of PSA processes. The trust-region update rules and sufficient decrease condition for the objective is used to determine the size of the trust-region. Based on the decrease in the objective function and error in the ROM, a ROM updation strategy is designed [4, 5]. The inequalities and bounds are handled in the algorithm using exact penalty formulation, and a non-smooth trust-region algorithm by Conn et al. [6] is used to handle non-differentiability. To ensure that the first order consistency condition is met and the optimum obtained from ROM-based optimization corresponds to the optimum of the original problem, a scaling function, such as one proposed by Alexandrov et al. [7], is incorporated in the objective function. Such error control mechanism is also capable of handling numerical inconsistencies such as unphysical oscillations in the state variable profiles. The proposed methodology is applied to optimize a PSA process to concentrate CO{sub 2} from a nitrogen-carbon dioxide mixture. As in [3], separate ROMs are developed for each operating step with different POD modes for each state variable. Numerical results will be presented for optimization case studies which involve maximizing CO{sub 2} recovery, feed throughput or minimizing overall power consumption.« less

  15. REGIONAL OXIDANT MODEL (ROM) USER'S GUIDE, PART 1: THE ROM PREPROCESSORS

    EPA Science Inventory

    The Regional Oxidant Model (ROM) determines hourly concentrations and fates of zone and 34 other chemical species over a scale of 1000 km x 1000 km for ozone "episodes" of up to one month's duration. he model structure, based on phenomenological concepts, consists of 3 1/2 layers...

  16. Wall Shear Stress Distribution in a Patient-Specific Cerebral Aneurysm Model using Reduced Order Modeling

    NASA Astrophysics Data System (ADS)

    Han, Suyue; Chang, Gary Han; Schirmer, Clemens; Modarres-Sadeghi, Yahya

    2016-11-01

    We construct a reduced-order model (ROM) to study the Wall Shear Stress (WSS) distributions in image-based patient-specific aneurysms models. The magnitude of WSS has been shown to be a critical factor in growth and rupture of human aneurysms. We start the process by running a training case using Computational Fluid Dynamics (CFD) simulation with time-varying flow parameters, such that these parameters cover the range of parameters of interest. The method of snapshot Proper Orthogonal Decomposition (POD) is utilized to construct the reduced-order bases using the training CFD simulation. The resulting ROM enables us to study the flow patterns and the WSS distributions over a range of system parameters computationally very efficiently with a relatively small number of modes. This enables comprehensive analysis of the model system across a range of physiological conditions without the need to re-compute the simulation for small changes in the system parameters.

  17. Development of Reduced-Order Models for Aeroelastic and Flutter Prediction Using the CFL3Dv6.0 Code

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Bartels, Robert E.

    2002-01-01

    A reduced-order model (ROM) is developed for aeroelastic analysis using the CFL3D version 6.0 computational fluid dynamics (CFD) code, recently developed at the NASA Langley Research Center. This latest version of the flow solver includes a deforming mesh capability, a modal structural definition for nonlinear aeroelastic analyses, and a parallelization capability that provides a significant increase in computational efficiency. Flutter results for the AGARD 445.6 Wing computed using CFL3D v6.0 are presented, including discussion of associated computational costs. Modal impulse responses of the unsteady aerodynamic system are then computed using the CFL3Dv6 code and transformed into state-space form. Important numerical issues associated with the computation of the impulse responses are presented. The unsteady aerodynamic state-space ROM is then combined with a state-space model of the structure to create an aeroelastic simulation using the MATLAB/SIMULINK environment. The MATLAB/SIMULINK ROM is used to rapidly compute aeroelastic transients including flutter. The ROM shows excellent agreement with the aeroelastic analyses computed using the CFL3Dv6.0 code directly.

  18. REGIONAL OXIDANT MODEL (ROM) USER'S GUIDE, PART 2: THE ROM PREPROCESSOR NETWORK

    EPA Science Inventory

    The Regional Oxidant Model (ROM) determines hourly concentrations and fates of zone and 34 other chemical species over a scale of 1000 km x 1000 km for ozone "episodes" of up to one month's duration. he model structure, based on phenomenological concepts, consists of 3 1/2 layers...

  19. Effect of partitioning the nonfiber carbohydrate fraction and neutral detergent fiber method on digestibility of carbohydrates by dairy cows.

    PubMed

    Tebbe, A W; Faulkner, M J; Weiss, W P

    2017-08-01

    Many nutrition models rely on summative equations to estimate feed and diet energy concentrations. These models partition feed into nutrient fractions and multiply the fractions by their estimated true digestibility, and the digestible mass provided by each fraction is then summed and converted to an energy value. Nonfiber carbohydrate (NFC) is used in many models. Although it behaves as a nutritionally uniform fraction, it is a heterogeneous mixture of components. To reduce the heterogeneity, we partitioned NFC into starch and residual organic matter (ROM), which is calculated as 100 - CP - LCFA - ash - starch - NDF, where crude protein (CP), long-chain fatty acids (LCFA), ash, starch, and neutral detergent fiber (NDF) are a percentage of DM. However, the true digestibility of ROM is unknown, and because NDF is contaminated with both ash and CP, those components are subtracted twice. The effect of ash and CP contamination of NDF on in vivo digestibility of NDF and ROM was evaluated using data from 2 total-collection digestibility experiments using lactating dairy cows. Digestibility of NDF was greater when it was corrected for ash and CP than without correction. Conversely, ROM apparent digestibility decreased when NDF was corrected for contamination. Although correcting for contamination statistically increased NDF digestibility, the effect was small; the average increase was 3.4%. The decrease in ROM digestibility was 7.4%. True digestibility of ROM is needed to incorporate ROM into summative equations. Data from multiple digestibility experiments (38 diets) using dairy cows were collated, and ROM concentrations were regressed on concentration of digestible ROM (ROM was calculated without adjusting for ash and CP contamination). The estimated true digestibility coefficient of ROM was 0.96 (SE = 0.021), and metabolic fecal ROM was 3.43 g/100 g of dry matter intake (SE = 0.30). Using a smaller data set (7 diets), estimated true digestibility of ROM when calculated using NDF corrected for ash and CP contamination was 0.87 (SE = 0.025), and metabolic fecal ROM was 3.76 g/100 g (SE = 0.60). Regardless of NDF method, ROM exhibited nutritional uniformity. The ROM fraction also had lower errors associated with the estimated true digestibility and its metabolic fecal fraction than did NFC. Therefore, ROM may result in more accurate estimates of available energy if integrated into models. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Characterization of the L4-L5-S1 motion segment using the stepwise reduction method.

    PubMed

    Jaramillo, Héctor Enrique; Puttlitz, Christian M; McGilvray, Kirk; García, José J

    2016-05-03

    The two aims of this study were to generate data for a more accurate calibration of finite element models including the L5-S1 segment, and to find mechanical differences between the L4-L5 and L5-S1 segments. Then, the range of motion (ROM) and facet forces for the L4-S1 segment were measured using the stepwise reduction method. This consists of sequentially testing and reducing each segment in nine stages by cutting the ligaments, facet capsules, and removing the nucleus. Five L4-S1 human segments (median: 65 years, range: 53-84 years, SD=11.0 years) were loaded under a maximum pure moment of 8Nm. The ROM was measured using stereo-photogrammetry via tracking of three markers and the facet contact forces (CF) were measured using a Tekscan system. The ROM for the L4-L5 segment and all stages showed good agreement with published data. The major differences in ROM between the L4-L5 and L5-S1 segments were found for lateral bending and all stages, for which the L4-L5 ROM was about 1.5-3 times higher than that of the L5-S1 segment, consistent with L5-S1 facet CF about 1.3 to 4 times higher than those measured for the L4-L5 segment. For the other movements and few stages, the L4-L5 ROM was significantly lower that of the L5-S1 segment. ROM and CF provide important baseline data for more accurate calibration of FE models and to understand the role that their structures play in lower lumbar spine mechanics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Stabilization Approaches for Linear and Nonlinear Reduced Order Models

    NASA Astrophysics Data System (ADS)

    Rezaian, Elnaz; Wei, Mingjun

    2017-11-01

    It has been a major concern to establish reduced order models (ROMs) as reliable representatives of the dynamics inherent in high fidelity simulations, while fast computation is achieved. In practice it comes to stability and accuracy of ROMs. Given the inviscid nature of Euler equations it becomes more challenging to achieve stability, especially where moving discontinuities exist. Originally unstable linear and nonlinear ROMs are stabilized here by two approaches. First, a hybrid method is developed by integrating two different stabilization algorithms. At the same time, symmetry inner product is introduced in the generation of ROMs for its known robust behavior for compressible flows. Results have shown a notable improvement in computational efficiency and robustness compared to similar approaches. Second, a new stabilization algorithm is developed specifically for nonlinear ROMs. This method adopts Particle Swarm Optimization to enforce a bounded ROM response for minimum discrepancy between the high fidelity simulation and the ROM outputs. Promising results are obtained in its application on the nonlinear ROM of an inviscid fluid flow with discontinuities. Supported by ARL.

  2. Challenges in Ocean Data Assimilation for the US West Coast

    NASA Astrophysics Data System (ADS)

    Li, Z.; Chao, Y.; Farrara, J.; Wang, X.

    2006-12-01

    A three-dimensional variational data assimilation (3DVAR) system has been developed for the Regional Ocean Modeling System (ROMS), and it is called ROMS-DAS. This system provides a capability of predicting meso- to small-scale variations with temporal scales from hours to days in the coastal oceans. To cope with the particular difficulties that result from complex coastlines and bottom topography, unbalanced flows and sparse observations, ROMS-DAS utilizes several novel strategies. These strategies include the implementation of three-dimensional anisotropic and inhomogeneous error correlations, application of particular weak dynamic constraints, and implementation of efficient and reliable algorithms for minimizing the cost function. The ROMS-DAS system was applied in field experiments for Monterey Bay during both 2003 (Autonomous Ocean Sampling Network - AOSN) and 2006 (MB06). These two experiments included intensive data collection from a variety of observational platforms, including satellites, airplanes, High Frequency radars, Acoustic Doppler Current Profilers, ships, drifters, buoys, autonomous underwater vehicles (AUV), and particularly a fleet of undersea gliders. Using these data sets, various data assimilation experiments were performed to address several major data assimilation challenges that arise from multi-scales structures, inhomogeneous properties, dynamical imbalance of the flow, and tides. Basing on these experiments, a set of strategies were formulated to deal with those challenges.

  3. CD-ROM Hardware Configurations: Selection and Design.

    ERIC Educational Resources Information Center

    Jaffe, Lee David; Watkins, Steven G.

    1992-01-01

    Presents selection and design considerations to help libraries make informed decisions about hardware configurations of CD-ROM systems. Highlights include CD-ROM configurations, including single drive workstations, daisychains, and jukeboxes; network configurations, including remote access; microcomputer features; CD-ROM drive selection; and…

  4. A Community Terrain-Following Ocean Modeling System (ROMS)

    DTIC Science & Technology

    2015-09-30

    funded NOPP project titled: Toward the Development of a Coupled COAMPS-ROMS Ensemble Kalman filter and adjoint with a focus on the Indian Ocean and the...surface temperature and surface salinity daily averages for 31-Jan-2014. Similarly, Figure 3 shows the sea surface height averaged solution for 31-Jan... temperature (upper panel; Celsius) and surface salinity (lower panel) for 31-Jan-2014. The refined solution for the Hudson Canyon grid is overlaid on

  5. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Sano, Tomoyuki; Suzuki, Masataka; Nishida, Hideo

    The Development of CAI system using CD-ROM and NAPLPS (North American Presentation Level Protocol Syntax) was taken place by Himeji Dokkyo University. The characteristics of CAI using CD-ROM as information processing series for the department of liberal arts student are described. The system is that the computer program, vast amount of voice data and graphics data are stored in a CD-ROM. It is very effective to improve learning ability of student.

  6. Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties

    PubMed Central

    Lindsey, Derek P; Perez-Orribo, Luis; Rodriguez-Martinez, Nestor; Reyes, Phillip M; Newcomb, Anna; Cable, Alexandria; Hickam, Grace; Yerby, Scott A; Crawford, Neil R

    2014-01-01

    Introduction Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading. Methods Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N · m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test. Results Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs. Discussion In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles. PMID:24868175

  7. A WWW-Based Archive and Retrieval System for Multimedia

    NASA Technical Reports Server (NTRS)

    Hyon, J.; Sorensen, S.; Martin, M.; Kawasaki, K.; Takacs, M.

    1996-01-01

    This paper describes the Data Distribution Laboratory (DDL) and discusses issues involved in building multimedia CD-ROMs. It describes the modeling philosophy for cataloging multimedia products and the worldwide-web (WWW)-based multimedia archive and retrieval system (Webcat) built on that model.

  8. Coupling of protein localization and cell movements by a dynamically localized response regulator in Myxococcus xanthus

    PubMed Central

    Leonardy, Simone; Freymark, Gerald; Hebener, Sabrina; Ellehauge, Eva; Søgaard-Andersen, Lotte

    2007-01-01

    Myxococcus xanthus cells harbor two motility machineries, type IV pili (Tfp) and the A-engine. During reversals, the two machineries switch polarity synchronously. We present a mechanism that synchronizes this polarity switching. We identify the required for motility response regulator (RomR) as essential for A-motility. RomR localizes in a bipolar, asymmetric pattern with a large cluster at the lagging cell pole. The large RomR cluster relocates to the new lagging pole in parallel with cell reversals. Dynamic RomR localization is essential for cell reversals, suggesting that RomR relocalization induces the polarity switching of the A-engine. The analysis of RomR mutants shows that the output domain targets RomR to the poles and the receiver domain is essential for dynamic localization. The small GTPase MglA establishes correct RomR polarity, and the Frz two-component system regulates dynamic RomR localization. FrzS localizes with Tfp at the leading pole and relocates in an Frz-dependent manner to the opposite pole during reversals; FrzS and RomR localize and oscillate independently. The Frz system synchronizes these oscillations and thus the synchronous polarity switching of the motility machineries. PMID:17932488

  9. Validation of an ocean shelf model for the prediction of mixed-layer properties in the Mediterranean Sea west of Sardinia

    NASA Astrophysics Data System (ADS)

    Onken, Reiner

    2017-04-01

    The Regional Ocean Modeling System (ROMS) has been employed to explore the sensitivity of the forecast skill of mixed-layer properties to initial conditions, boundary conditions, and vertical mixing parameterisations. The initial and lateral boundary conditions were provided by the Mediterranean Forecasting System (MFS) or by the MERCATOR global ocean circulation model via one-way nesting; the initial conditions were additionally updated through the assimilation of observations. Nowcasts and forecasts from the weather forecast models COSMO-ME and COSMO-IT, partly melded with observations, served as surface boundary conditions. The vertical mixing was parameterised by the GLS (generic length scale) scheme Umlauf and Burchard (2003) in four different set-ups. All ROMS forecasts were validated against the observations which were taken during the REP14-MED survey to the west of Sardinia. Nesting ROMS in MERCATOR and updating the initial conditions through data assimilation provided the best agreement of the predicted mixed-layer properties with the time series from a moored thermistor chain. Further improvement was obtained by the usage of COSMO-ME atmospheric forcing, which was melded with real observations, and by the application of the k-ω vertical mixing scheme with increased vertical eddy diffusivity. The predicted temporal variability of the mixed-layer temperature was reasonably well correlated with the observed variability, while the modelled variability of the mixed-layer depth exhibited only agreement with the observations near the diurnal frequency peak. For the forecasted horizontal variability, reasonable agreement was found with observations from a ScanFish section, but only for the mesoscale wave number band; the observed sub-mesoscale variability was not reproduced by ROMS.

  10. A high-speed, large-capacity, 'jukebox' optical disk system

    NASA Technical Reports Server (NTRS)

    Ammon, G. J.; Calabria, J. A.; Thomas, D. T.

    1985-01-01

    Two optical disk 'jukebox' mass storage systems which provide access to any data in a store of 10 to the 13th bits (1250G bytes) within six seconds have been developed. The optical disk jukebox system is divided into two units, including a hardware/software controller and a disk drive. The controller provides flexibility and adaptability, through a ROM-based microcode-driven data processor and a ROM-based software-driven control processor. The cartridge storage module contains 125 optical disks housed in protective cartridges. Attention is given to a conceptual view of the disk drive unit, the NASA optical disk system, the NASA database management system configuration, the NASA optical disk system interface, and an open systems interconnect reference model.

  11. Hemodynamics of a Patient-Specific Aneurysm Model with Proper Orthogonal Decomposition

    NASA Astrophysics Data System (ADS)

    Han, Suyue; Chang, Gary Han; Modarres-Sadeghi, Yahya

    2017-11-01

    Wall shear stress (WSS) and oscillatory shear index (OSI) are two of the most-widely studied hemodynamic quantities in cardiovascular systems that have been shown to have the ability to elicit biological responses of the arterial wall, which could be used to predict the aneurysm development and rupture. In this study, a reduced-order model (ROM) of the hemodynamics of a patient-specific cerebral aneurysm is studied. The snapshot Proper Orthogonal Decomposition (POD) is utilized to construct the reduced-order bases of the flow using a CFD training set with known inflow parameters. It was shown that the area of low WSS and high OSI is correlated to higher POD modes. The resulting ROM can reproduce both WSS and OSI computationally for future parametric studies with significantly less computational cost. Agreement was observed between the WSS and OSI values obtained using direct CFD results and ROM results.

  12. Downscaling of sea level and fluxes in the Malacca and Singapore Straits using A2 scenario projections of AR4 GCMs

    NASA Astrophysics Data System (ADS)

    Tkalich, Pavel; Koshebutsky, Volodymyr; Maderich, Vladimir; Thompson, Bijoy

    2013-04-01

    IPCC-coordinated work has been completed within Fourth Assessment Report (AR4) to project climate and ocean variables for the 21st century using coupled atmospheric-ocean General Circulation Models (GCMs). Resolution of the GCMs is not sufficient to resolve local features of narrow Malacca and Singapore Straits, having complex coastal line and bathymetry; therefore, dynamical downscaling of ocean variables from the global grid to the regional scale is advisable using ocean models, such as Regional Ocean Modeling System (ROMS). ROMS is customized for the domain centered on the Singapore and Malacca Straits, extending from 98°E to 109°E and 6°S to 14°N. Following IPCC methodology, the modelling is done for the past reference period 1961-1990, and then for the 21st century projections; subsequently, established past and projected trends and variability of ocean parameters are inter-compared. Boundary conditions for the past reference period are extracted from Simple Ocean Data Assimilation (SODA), while the projections are made using A2 scenario runs of ECHAM5 and CCSM3 GCMs. Atmospheric forcing for ROMS is downscaled with WRF using ERA-40 dataset for the past period, and outputs of atmospheric variables of respective GCMs for the projections. ROMS-downscaled regional sea level change during 1961-1990, corrected for the global thermosteric effect, land-ice melting and Global Isostatic Adjustment (GIA) effect, corresponds to a mean total trend of 1.52 mm/year, which is higher than the global estimate 1.25 mm/year and observed global sea-level rise (1.44 mm/year) for the same period. Local linear trend in the Singapore Strait (0.9 mm/year) corresponds to the observed trend at Victoria Dock tide gauge (1.1 mm/year) for the past period. Mean discharges through the Karimata, Malacca and Singapore Straits are 0.9, 0.21 and 0.12 Sv, respectively, fall in the range of observations and recent model estimates. A2 scenario projections using ROMS-ECHAM5 and ROMS-CCSM3 for 2011-2099 suggest that linear trends of sea level rise in Singapore Strait are 5.4 and 6.1 mm/year, respectively. These values fall in the range of global estimates of 3.0-8.5 mm/year. Mean sea level rise is expected around 0.43 m (ROMS-ECHAM5) and 0.47 m (ROMS-CCSM3) in 2099 relative to mean sea level in 2011. These values are greater than median estimation of global sea rise 0.32 under scenario A2. Mean discharge through Singapore Strait for scenario A2 during 2011 to 2099 is projected to be 0.062 Sv for ROMS-ECHAM5 and 0.11 Sv for ROMS-CCSM3. These projections are comparable to the discharges during 1961-1990 (0.065 and 0.11 Sv, respectively). The linear trend in discharges for the period 2011-2099 is relatively small with statistical confidence level being less than 95%. An important feature computationally discovered is the transient reversal of flow in the Singapore Strait during southwest monsoon. In general, the reversals of flow in ROMS-ECHAM5 and ROMS-CCSM3 are observed respectively to occur 1/3 and 1/5 of the whole period.

  13. CD-ROM Growth: Unleashing the Potential.

    ERIC Educational Resources Information Center

    Nelson, Nancy Melin

    1991-01-01

    Discusses the use of CD-ROMs in library processing and public services units. Topics discussed include local area networks, workstations, network security, search software, disk operating systems (DOS), computer viruses, CD-ROM selection and acquisition, licensing, and standards. A sidebar lists current CD-ROM products appropriate for reference…

  14. Reduced order model based on principal component analysis for process simulation and optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lang, Y.; Malacina, A.; Biegler, L.

    2009-01-01

    It is well-known that distributed parameter computational fluid dynamics (CFD) models provide more accurate results than conventional, lumped-parameter unit operation models used in process simulation. Consequently, the use of CFD models in process/equipment co-simulation offers the potential to optimize overall plant performance with respect to complex thermal and fluid flow phenomena. Because solving CFD models is time-consuming compared to the overall process simulation, we consider the development of fast reduced order models (ROMs) based on CFD results to closely approximate the high-fidelity equipment models in the co-simulation. By considering process equipment items with complicated geometries and detailed thermodynamic property models,more » this study proposes a strategy to develop ROMs based on principal component analysis (PCA). Taking advantage of commercial process simulation and CFD software (for example, Aspen Plus and FLUENT), we are able to develop systematic CFD-based ROMs for equipment models in an efficient manner. In particular, we show that the validity of the ROM is more robust within well-sampled input domain and the CPU time is significantly reduced. Typically, it takes at most several CPU seconds to evaluate the ROM compared to several CPU hours or more to solve the CFD model. Two case studies, involving two power plant equipment examples, are described and demonstrate the benefits of using our proposed ROM methodology for process simulation and optimization.« less

  15. Intercomparison of Antarctic ice-shelf, ocean, and sea-ice interactions simulated by MetROMS-iceshelf and FESOM 1.4

    NASA Astrophysics Data System (ADS)

    Naughten, Kaitlin A.; Meissner, Katrin J.; Galton-Fenzi, Benjamin K.; England, Matthew H.; Timmermann, Ralph; Hellmer, Hartmut H.; Hattermann, Tore; Debernard, Jens B.

    2018-04-01

    An increasing number of Southern Ocean models now include Antarctic ice-shelf cavities, and simulate thermodynamics at the ice-shelf/ocean interface. This adds another level of complexity to Southern Ocean simulations, as ice shelves interact directly with the ocean and indirectly with sea ice. Here, we present the first model intercomparison and evaluation of present-day ocean/sea-ice/ice-shelf interactions, as simulated by two models: a circumpolar Antarctic configuration of MetROMS (ROMS: Regional Ocean Modelling System coupled to CICE: Community Ice CodE) and the global model FESOM (Finite Element Sea-ice Ocean Model), where the latter is run at two different levels of horizontal resolution. From a circumpolar Antarctic perspective, we compare and evaluate simulated ice-shelf basal melting and sub-ice-shelf circulation, as well as sea-ice properties and Southern Ocean water mass characteristics as they influence the sub-ice-shelf processes. Despite their differing numerical methods, the two models produce broadly similar results and share similar biases in many cases. Both models reproduce many key features of observations but struggle to reproduce others, such as the high melt rates observed in the small warm-cavity ice shelves of the Amundsen and Bellingshausen seas. Several differences in model design show a particular influence on the simulations. For example, FESOM's greater topographic smoothing can alter the geometry of some ice-shelf cavities enough to affect their melt rates; this improves at higher resolution, since less smoothing is required. In the interior Southern Ocean, the vertical coordinate system affects the degree of water mass erosion due to spurious diapycnal mixing, with MetROMS' terrain-following coordinate leading to more erosion than FESOM's z coordinate. Finally, increased horizontal resolution in FESOM leads to higher basal melt rates for small ice shelves, through a combination of stronger circulation and small-scale intrusions of warm water from offshore.

  16. Introducing students to ocean modeling via a web-based implementation for the Regional Ocean Modeling System (ROMS) river plume case study

    NASA Astrophysics Data System (ADS)

    Harris, C. K.; Overeem, I.; Hutton, E.; Moriarty, J.; Wiberg, P.

    2016-12-01

    Numerical models are increasingly used for both research and applied sciences, and it is important that we train students to run models and analyze model data. This is especially true within oceanographic sciences, many of which use hydrodynamic models to address oceanographic transport problems. These models, however, often require a fair amount of training and computer skills before a student can run the models and analyze the large data sets produced by the models. One example is the Regional Ocean Modeling System (ROMS), an open source, three-dimensional primitive equation hydrodynamic ocean model that uses a structured curvilinear horizontal grid. It currently has thousands of users worldwide, and the full model includes modules for sediment transport and biogeochemistry, and several options for turbulence closures and numerical schemes. Implementing ROMS can be challenging to students, however, in part because the code was designed to provide flexibility for the choice of model parameterizations and processes, and to run on a variety of High Performance Computing (HPC) platforms. To provide a more accessible tool for classroom use, we have modified an existing idealized ROMS implementation to be run on a High Performance Computer (HPC) via the WMT (Web Modeling Toolkit), and developed a series of lesson plans that explore sediment transport within the idealized model domain. This has addressed our goal to provide a relatively easy introduction to the numerical modeling process that can be used within upper level undergraduate and graduate classes to explore sediment transport on continental shelves. The model implementation includes wave forcing, along-shelf currents, a riverine source, and suspended sediment transport. The model calculates suspended transport and deposition of sediment delivered to the continental shelf by a riverine flood. Lesson plans lead the students through running the model on a remote HPC, modifying the standard model. The lesson plans also include instruction for visualizing the model output within Matlab and Panoply. The lesson plans have been used within graduate, undergraduate classrooms, as well as in clinics aimed at educators. Feedback from these exercises has been used to improve the lesson plans and model implementation.

  17. Multisensory Public Access Catalogs on CD-ROM.

    ERIC Educational Resources Information Center

    Harrison, Nancy; Murphy, Brower

    1987-01-01

    BiblioFile Intelligent Catalog is a CD-ROM-based public access catalog system which incorporates graphics and sound to provide a multisensory interface and artificial intelligence techniques to increase search precision. The system can be updated frequently and inexpensively by linking hard disk drives to CD-ROM optical drives. (MES)

  18. CD-ROM in the age of internet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conrad, B.; Depp, D.

    1994-12-31

    Networks are hot and CD-ROM is also hot, but how do they mix? CD-ROM is a relatively inexpensive medium for storing and delivering information, and increasingly, users are connected to networks. But the technologies have developed separately, and there are obstacles to their integration. Drawing on their experience networking CD-ROMs at Oak Ridge National Laboratory, the authors discuss CD-ROM`s strengths and weaknesses as a technology for delivering information to the desktop. CD-ROM networking solutions are LAN-based, not ``open systems.`` Despite this limitation, due to the large number of information resources available on CD-ROM and the relative ease of installing andmore » maintaining databases on CD-ROM, CD-ROMs remain an essential piece of the electronic information puzzle.« less

  19. Reduced order modeling of fluid/structure interaction.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barone, Matthew Franklin; Kalashnikova, Irina; Segalman, Daniel Joseph

    2009-11-01

    This report describes work performed from October 2007 through September 2009 under the Sandia Laboratory Directed Research and Development project titled 'Reduced Order Modeling of Fluid/Structure Interaction.' This project addresses fundamental aspects of techniques for construction of predictive Reduced Order Models (ROMs). A ROM is defined as a model, derived from a sequence of high-fidelity simulations, that preserves the essential physics and predictive capability of the original simulations but at a much lower computational cost. Techniques are developed for construction of provably stable linear Galerkin projection ROMs for compressible fluid flow, including a method for enforcing boundary conditions that preservesmore » numerical stability. A convergence proof and error estimates are given for this class of ROM, and the method is demonstrated on a series of model problems. A reduced order method, based on the method of quadratic components, for solving the von Karman nonlinear plate equations is developed and tested. This method is applied to the problem of nonlinear limit cycle oscillations encountered when the plate interacts with an adjacent supersonic flow. A stability-preserving method for coupling the linear fluid ROM with the structural dynamics model for the elastic plate is constructed and tested. Methods for constructing efficient ROMs for nonlinear fluid equations are developed and tested on a one-dimensional convection-diffusion-reaction equation. These methods are combined with a symmetrization approach to construct a ROM technique for application to the compressible Navier-Stokes equations.« less

  20. Wireless wearable range-of-motion sensor system for upper and lower extremity joints: a validation study.

    PubMed

    Kumar, Yogaprakash; Yen, Shih-Cheng; Tay, Arthur; Lee, Wangwei; Gao, Fan; Zhao, Ziyi; Li, Jingze; Hon, Benjamin; Tian-Ma Xu, Tim; Cheong, Angela; Koh, Karen; Ng, Yee-Sien; Chew, Effie; Koh, Gerald

    2015-02-01

    Range-of-motion (ROM) assessment is a critical assessment tool during the rehabilitation process. The conventional approach uses the goniometer which remains the most reliable instrument but it is usually time-consuming and subject to both intra- and inter-therapist measurement errors. An automated wireless wearable sensor system for the measurement of ROM has previously been developed by the current authors. Presented is the correlation and accuracy of the automated wireless wearable sensor system against a goniometer in measuring ROM in the major joints of upper (UEs) and lower extremities (LEs) in 19 healthy subjects and 20 newly disabled inpatients through intra (same) subject comparison of ROM assessments between the sensor system against goniometer measurements by physical therapists. In healthy subjects, ROM measurements using the new sensor system were highly correlated with goniometry, with 95% of differences < 20° and 10° for most movements in major joints of UE and LE, respectively. Among inpatients undergoing rehabilitation, ROM measurements using the new sensor system were also highly correlated with goniometry, with 95% of the differences being < 20° and 25° for most movements in the major joints of UE and LE, respectively.

  1. Development and test of a model for designing interactive CD-ROMs for teaching nursing skills.

    PubMed

    Jeffries, P R

    2000-01-01

    The use of interactive multimedia is well documented in the education literature as a medium for learning. Many schools of nursing and healthcare agencies purchase commercially-made CD-ROM products, and, in other cases, educators develop their own. Since nurses are increasingly designing CD-ROMs, they must be aware of the instructional design needed to develop comprehensive and effective CD-ROMs that do not compromise the quality of education. This article describes a process for developing and testing an interactive, multimedia CD-ROM on oral medication administration, using an instructional design model based on Chickering and Gamson's Principles of Good Practices in Education. Results from testing the model are reported. The findings can be used to guide the work of nurse educators who are interested in developing educational software.

  2. An operational coupled wave-current forecasting system for the northern Adriatic Sea

    NASA Astrophysics Data System (ADS)

    Russo, A.; Coluccelli, A.; Deserti, M.; Valentini, A.; Benetazzo, A.; Carniel, S.

    2012-04-01

    Since 2005 an Adriatic implementation of the Regional Ocean Modeling System (AdriaROMS) is being producing operational short-term forecasts (72 hours) of some hydrodynamic properties (currents, sea level, temperature, salinity) of the Adriatic Sea at 2 km horizontal resolution and 20 vertical s-levels, on a daily basis. The main objective of AdriaROMS, which is managed by the Hydro-Meteo-Clima Service (SIMC) of ARPA Emilia Romagna, is to provide useful products for civil protection purposes (sea level forecasts, outputs to run other forecasting models as for saline wedge, oil spills and coastal erosion). In order to improve the forecasts in the coastal area, where most of the attention is focused, a higher resolution model (0.5 km, again with 20 vertical s-levels) has been implemented for the northern Adriatic domain. The new implementation is based on the Coupled-Ocean-Atmosphere-Wave-Sediment Transport Modeling System (COAWST)and adopts ROMS for the hydrodynamic and Simulating WAve Nearshore (SWAN) for the wave module, respectively. Air-sea fluxes are computed using forecasts produced by the COSMO-I7 operational atmospheric model. At the open boundary of the high resolution model, temperature, salinity and velocity fields are provided by AdriaROMS while the wave characteristics are provided by an operational SWAN implementation (also managed by SIMC). Main tidal components are imposed as well, derived from a tidal model. Work in progress is oriented now on the validation of model results by means of extensive comparisons with acquired hydrographic measurements (such as CTDs or XBTs from sea-truth campaigns), currents and waves acquired at observational sites (including those of SIMC, CNR-ISMAR network and its oceanographic tower, located off the Venice littoral) and satellite-derived wave-heights data. Preliminary results on the forecast waves denote how, especially during intense storms, the effect of coupling can lead to significant variations in the wave heights. Part of the activity has been funded by the EU FP VII program (project "MICORE", contract n. 202798) and by the Regione Veneto regional law 15/2007 (Progetto "MARINA").

  3. Different coupled atmosphere-recharge oscillator Low Order Models for ENSO: a projection approach.

    NASA Astrophysics Data System (ADS)

    Bianucci, Marco; Mannella, Riccardo; Merlino, Silvia; Olivieri, Andrea

    2016-04-01

    El Ninõ-Southern Oscillation (ENSO) is a large scale geophysical phenomenon where, according to the celebrated recharge oscillator model (ROM), the Ocean slow variables given by the East Pacific Sea Surface Temperature (SST) and the average thermocline depth (h), interact with some fast "irrelevant" ones, representing mostly the atmosphere (the westerly wind burst and the Madden-Julian Oscillation). The fast variables are usually inserted in the model as an external stochastic forcing. In a recent work (M. Bianucci, "Analytical probability density function for the statistics of the ENSO phenomenon: asymmetry and power law tail" Geophysical Research Letters, under press) the author, using a projection approach applied to general deterministic coupled systems, gives a physically reasonable explanation for the use of stochastic models for mimicking the apparent random features of the ENSO phenomenon. Moreover, in the same paper, assuming that the interaction between the ROM and the fast atmosphere is of multiplicative type, i.e., it depends on the SST variable, an analytical expression for the equilibrium density function of the anomaly SST is obtained. This expression fits well the data from observations, reproducing the asymmetry and the power law tail of the histograms of the NINÕ3 index. Here, using the same theoretical approach, we consider and discuss different kind of interactions between the ROM and the other perturbing variables, and we take into account also non linear ROM as a low order model for ENSO. The theoretical and numerical results are then compared with data from observations.

  4. Inference of turbulence parameters from a ROMS simulation using the k-ε closure scheme

    NASA Astrophysics Data System (ADS)

    Thyng, Kristen M.; Riley, James J.; Thomson, Jim

    2013-12-01

    Comparisons between high resolution turbulence data from Admiralty Inlet, WA (USA), and a 65-meter horizontal grid resolution simulation using the hydrostatic ocean modelling code, Regional Ocean Modeling System (ROMS), show that the model's k-ε turbulence closure scheme performs reasonably well. Turbulent dissipation rates and Reynolds stresses agree within a factor of two, on average. Turbulent kinetic energy (TKE) also agrees within a factor of two, but only for motions within the observed inertial sub-range of frequencies (i.e., classic approximately isotropic turbulence). TKE spectra from the observations indicate that there is significant energy at lower frequencies than the inertial sub-range; these scales are not captured by the model closure scheme nor the model grid resolution. To account for scales not present in the model, the inertial sub-range is extrapolated to lower frequencies and then integrated to obtain an inferred, diagnostic total TKE, with improved agreement with the observed total TKE. The realistic behavior of the dissipation rate and Reynolds stress, combined with the adjusted total TKE, imply that ROMS simulations can be used to understand and predict spatial and temporal variations in turbulence. The results are suggested for application to siting tidal current turbines.

  5. Sensitivity of sea-level forecasting to the horizontal resolution and sea surface forcing for different configurations of an oceanographic model of the Adriatic Sea

    NASA Astrophysics Data System (ADS)

    Bressan, Lidia; Valentini, Andrea; Paccagnella, Tiziana; Montani, Andrea; Marsigli, Chiara; Stefania Tesini, Maria

    2017-04-01

    At the Hydro-meteo-climate service of the Regional environmental agency of Emilia-Romagna, Italy (Arpae-SIMC), the oceanographic numerical model AdriaROMS is used in the operational forecasting suite to compute sea level, temperature, salinity and 3-D current fields of the Adriatic Sea (northern Mediterranean Sea). In order to evaluate the performance of the sea-level forecast and to study different configurations of the ROMS model, two marine storms occurred on the Emilia Romagna coast during the winter 2015-2016 are investigated. The main focus of this study is to analyse the sensitivity of the model to the horizontal resolution and to the meteorological forcing. To this end, the model is run with two different configurations and with two horizontal grids at 1 and 2 km resolution. To study the influence of the meteorological forcing, the two storms have been reproduced by running ROMS in ensemble mode, forced by the 16-members of the meteorological ensemble COSMO-LEPS system. Possible optimizations of the model set-up are deduced by the comparison of the different run outputs.

  6. Simulation and optimization of pressure swing adsorption systmes using reduced-order modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, A.; Biegler, L.; Zitney, S.

    2009-01-01

    Over the past three decades, pressure swing adsorption (PSA) processes have been widely used as energyefficient gas separation techniques, especially for high purity hydrogen purification from refinery gases. Models for PSA processes are multiple instances of partial differential equations (PDEs) in time and space with periodic boundary conditions that link the processing steps together. The solution of this coupled stiff PDE system is governed by steep fronts moving with time. As a result, the optimization of such systems represents a significant computational challenge to current differential algebraic equation (DAE) optimization techniques and nonlinear programming algorithms. Model reduction is one approachmore » to generate cost-efficient low-order models which can be used as surrogate models in the optimization problems. This study develops a reducedorder model (ROM) based on proper orthogonal decomposition (POD), which is a low-dimensional approximation to a dynamic PDE-based model. The proposed method leads to a DAE system of significantly lower order, thus replacing the one obtained from spatial discretization and making the optimization problem computationally efficient. The method has been applied to the dynamic coupled PDE-based model of a twobed four-step PSA process for separation of hydrogen from methane. Separate ROMs have been developed for each operating step with different POD modes for each of them. A significant reduction in the order of the number of states has been achieved. The reduced-order model has been successfully used to maximize hydrogen recovery by manipulating operating pressures, step times and feed and regeneration velocities, while meeting product purity and tight bounds on these parameters. Current results indicate the proposed ROM methodology as a promising surrogate modeling technique for cost-effective optimization purposes.« less

  7. Testing biomechanical models of human lumbar lordosis variability.

    PubMed

    Castillo, Eric R; Hsu, Connie; Mair, Ross W; Lieberman, Daniel E

    2017-05-01

    Lumbar lordosis (LL) is a key adaptation for bipedalism, but factors underlying curvature variations remain unclear. This study tests three biomechanical models to explain LL variability. Thirty adults (15 male, 15 female) were scanned using magnetic resonance imaging (MRI), a standing posture analysis was conducted, and lumbar range of motion (ROM) was assessed. Three measures of LL were compared. The trunk's center of mass was estimated from external markers to calculate hip moments (M hip ) and lumbar flexion moments. Cross-sectional areas of lumbar vertebral bodies and trunk muscles were measured from scans. Regression models tested associations between LL and the M hip moment arm, a beam bending model, and an interaction between relative trunk strength (RTS) and ROM. Hip moments were not associated with LL. Beam bending was moderately predictive of standing but not supine LL (R 2  = 0.25). Stronger backs and increased ROM were associated with greater LL, especially when standing (R 2  = 0.65). The strength-flexibility model demonstrates the differential influence of RTS depending on ROM: individuals with high ROM exhibited the most LL variation with RTS, while those with low ROM showed reduced LL regardless of RTS. Hip moments appear constrained suggesting the possibility of selection, and the beam model explains some LL variability due to variations in trunk geometry. The strength-flexibility interaction best predicted LL, suggesting a tradeoff in which ROM limits the effects of back strength on LL. The strength-flexibility model may have clinical relevance for spinal alignment and pathology. This model may also suggest that straight-backed Neanderthals had reduced lumbar mobility. © 2017 Wiley Periodicals, Inc.

  8. REVEAL: An Extensible Reduced Order Model Builder for Simulation and Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Khushbu; Sharma, Poorva; Ma, Jinliang

    2013-04-30

    Many science domains need to build computationally efficient and accurate representations of high fidelity, computationally expensive simulations. These computationally efficient versions are known as reduced-order models. This paper presents the design and implementation of a novel reduced-order model (ROM) builder, the REVEAL toolset. This toolset generates ROMs based on science- and engineering-domain specific simulations executed on high performance computing (HPC) platforms. The toolset encompasses a range of sampling and regression methods that can be used to generate a ROM, automatically quantifies the ROM accuracy, and provides support for an iterative approach to improve ROM accuracy. REVEAL is designed to bemore » extensible in order to utilize the core functionality with any simulator that has published input and output formats. It also defines programmatic interfaces to include new sampling and regression techniques so that users can ‘mix and match’ mathematical techniques to best suit the characteristics of their model. In this paper, we describe the architecture of REVEAL and demonstrate its usage with a computational fluid dynamics model used in carbon capture.« less

  9. CD-ROM and Metering--An Overview.

    ERIC Educational Resources Information Center

    Shear, Victor

    1992-01-01

    Discusses the need for security and metering features for CD-ROM products. Topics covered include user productivity issues, pricing problems, integrated information resources, advantages of CD-ROM distribution systems, unauthorized use, content encryption, and multiple simultaneous meters. (MES)

  10. The Market Place: An Internal View of the Future of CD-ROM--The Perspective of the H. W. Wilson Company.

    ERIC Educational Resources Information Center

    Miller, Frank W.; Loeding, Deborah Voigt

    1989-01-01

    Discussion of technological developments in library reference services focuses on contributions of the H. W. Wilson Company and highlights CD-ROM technology. Topics discussed include online access; menu-driven systems; CD-ROM hardware and software concerns; user response to CD-ROM; quality control of databases; pricing considerations; and future…

  11. Energy balance and mass conservation in reduced order models of fluid flows

    NASA Astrophysics Data System (ADS)

    Mohebujjaman, Muhammad; Rebholz, Leo G.; Xie, Xuping; Iliescu, Traian

    2017-10-01

    In this paper, we investigate theoretically and computationally the conservation properties of reduced order models (ROMs) for fluid flows. Specifically, we investigate whether the ROMs satisfy the same (or similar) energy balance and mass conservation as those satisfied by the Navier-Stokes equations. All of our theoretical findings are illustrated and tested in numerical simulations of a 2D flow past a circular cylinder at a Reynolds number Re = 100. First, we investigate the ROM energy balance. We show that using the snapshot average for the centering trajectory (which is a popular treatment of nonhomogeneous boundary conditions in ROMs) yields an incorrect energy balance. Then, we propose a new approach, in which we replace the snapshot average with the Stokes extension. Theoretically, the Stokes extension produces an accurate energy balance. Numerically, the Stokes extension yields more accurate results than the standard snapshot average, especially for longer time intervals. Our second contribution centers around ROM mass conservation. We consider ROMs created using two types of finite elements: the standard Taylor-Hood (TH) element, which satisfies the mass conservation weakly, and the Scott-Vogelius (SV) element, which satisfies the mass conservation pointwise. Theoretically, the error estimates for the SV-ROM are sharper than those for the TH-ROM. Numerically, the SV-ROM yields significantly more accurate results, especially for coarser meshes and longer time intervals.

  12. [Analyses of segment motor function in patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system].

    PubMed

    Wu, Junsong; Du, Junhua; Jiang, Xiangyun; Wang, Quan; Li, Xigong; Du, Jingyu; Lin, Xiangjin

    2014-06-17

    To explore the changes of range-of-motion (ROM) in patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system and examine the postoperative lumbar regularity and tendency of ROM. Nine patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system were followed up with respect to ROMs at 5 timepoints within 12 months. Records of ROM were made for instrumented segments, adjacent segments and total lumbar. Compared with preoperation, ROMs in non-fusional segments with WavefleX dynamic stabilization system decreased statistical significantly (P < 0.05 or P < 0.01) at different timepoints; ROMs in adjacent segments increased at some levels without wide statistical significance. The exception was single L3/4 at Month 12 (P < 0.05) versus control group simultaneously at the levels of L3/4, L4/5 and L5/S1, ROMs decreased at Months 6 and 12 with wide statistical significance (P < 0.05 or P < 0.01). ROMs in total lumbar had statistical significant decrease (P < 0.01) in both group of non-fusional segments and hybrid group of non-fusion and fusion. The trends of continuous augments were observed during follow-ups. Statistically significant augments were also acquired at 4 timepoints as compared to control group (P < 0.01). The treatment of degenerative lumbar diseases with WavefleX dynamic stabilization system may limit excessive extension/inflexion and preserve some motor functions. Moreover, it can sustain physiological lordosis, decrease and transfer disc load in adjacent segments to prevent early degeneration of adjacent segment. Trends of motor function augment in total lumbar need to be confirmed during future long-term follow-ups.

  13. CD-ROM: towards a strategy for teaching and learning.

    PubMed

    Aarvold, J; Walton, G

    1992-12-01

    Compact Disc Read Only Memory (CD-ROM) represents an exciting innovation in nurse education yet paradoxically has a potential to induce disillusionment and frustration. Purchasers of systems may well find that their investment does not bring the benefits they had been lead to expect. CD-ROM systems have the capacity to generate huge quantities of data on an equally large number of nursing topics. Arguably this very capability ensures certain 'built-in' problems. The purpose of this articles is to provide nurse teachers with information about CD-ROM, to highlight the resource implications of CD-ROM use and to consider the relative merits of various teaching and learning methods. To be worthwhile, strategies developed must be part of an information retrieval skills programme.

  14. Relationship between ankle range of motion and Biodex Balance System in females and males.

    PubMed

    Sung, Eun-Sook; Kim, Jung-Hyun

    2018-02-01

    This study examined whether there are differences between range of motion (ROM) and balance in lower extremities according to gender. A total of 31 male and 28 female students measured plantar flexion (PF), dorsiflexion, inversion (IV), eversion (EV), hip flexion (HF), hip internal rotation (HIR), and hip external rotation (HER) and tested on the Biodex Balance System. ROM of PF and HF were significantly high the female group and ROMs of IV, EV, HIR, and HER were significantly higher the male group than in the female group. Low ROM of PF may be more negative related to overall balance, especially, back balance in males; therefore, it is necessary to assess and plan the training program for PF ROM in male students.

  15. Validation of Model Output versus ADCP Observations on the PR Insular Shelf, Part 2: Are all Sites the Same?

    NASA Astrophysics Data System (ADS)

    Ramos Valle, A.

    2016-02-01

    We have previously compared the output from three oceanographic models against observed data from an ADCP at a common grid point location on the zonally oriented, southwestern Puerto Rico shelf that extends into the northern Caribbean Sea. The three models were: 1) AMSEAS (NCOM), 2) Regional ROMS and 3) a higher resolution version of ROMS nested within the Regional ROMS. These models faced great difficulty in accurately depicting the bathymetry of the ocean in the PR-USVI archipelago which is characterized by small islands, narrow insular shelves, steep slopes and deep water beyond. The resulting validations of the three models versus the ADCP at the selected location were poor. However, the insight we gained into the behavior of the models during the validation process suggested that models might do a better job at simulating currents across the inter-island straits that connect the Atlantic Ocean with the Caribbean Sea than along the insular Caribbean or Atlantic coastlines. We therefore focused our attention on expanding our previous research by performing a similar analysis using the ROMS model against ADCP observations in the Mona Passage, west of PR. This new ADCP location exhibits bathymetric features that are smoother, less complex, and better represented in the Regional ROMS model while flows at the site are stronger than at the previous ADCP site at La Parguera. Statistical time-series analyses are performed on model and ADCP flow velocity time series to quantify the model's skill. Results indicate that ROMS does a much better job at simulating ocean currents at the Mona Passage site than at La Parguera. Dynamical and numerical differences that might explain the spatially varying model skill are considered. In summary: model skill validation sites around PR are not all the same.

  16. Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    PubMed

    Hajibozorgi, M; Arjmand, N

    2016-04-11

    Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvis, and entire trunk (T1) ROMs were measured using an inertial tracking device as asymptomatic subjects flexed forward from their neutral upright position to full forward flexion. Correlations between body height and the ROMs were conducted. An effect of measurement errors of the trunk flexion (T1) on the model-predicted spinal loads was investigated. Mean of peak voluntary total flexion of trunk (T1) was 118.4 ± 13.9°, of which 20.5 ± 6.5° was generated by flexion of the T1 to T12 (thoracic ROM), and the remaining by flexion of the T12 to S1 (lumbar ROM) (50.2 ± 7.0°) and pelvis (47.8 ± 6.9°). Lower thoracic ROM was significantly larger than upper thoracic ROM (14.8 ± 5.4° versus 5.8 ± 3.1°). There were non-significant weak correlations between body height and the ROMs. Contribution of the pelvis to generate the total trunk flexion increased from ~20% to 40% and that of the lumbar decreased from ~60% to 42% as subjects flexed forward from upright to maximal flexion while that of the thoracic spine remained almost constant (~16% to 20%) during the entire movement. Small uncertainties (±5°) in the measurement of trunk flexion angle resulted in considerable errors (~27%) in the model-predicted spinal loads only in activities involving small trunk flexion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Incorporating ligament laxity in a finite element model for the upper cervical spine.

    PubMed

    Lasswell, Timothy L; Cronin, Duane S; Medley, John B; Rasoulinejad, Parham

    2017-11-01

    Predicting physiological range of motion (ROM) using a finite element (FE) model of the upper cervical spine requires the incorporation of ligament laxity. The effect of ligament laxity can be observed only on a macro level of joint motion and is lost once ligaments have been dissected and preconditioned for experimental testing. As a result, although ligament laxity values are recognized to exist, specific values are not directly available in the literature for use in FE models. The purpose of the current study is to propose an optimization process that can be used to determine a set of ligament laxity values for upper cervical spine FE models. Furthermore, an FE model that includes ligament laxity is applied, and the resulting ROM values are compared with experimental data for physiological ROM, as well as experimental data for the increase in ROM when a Type II odontoid fracture is introduced. The upper cervical spine FE model was adapted from a 50th percentile male full-body model developed with the Global Human Body Models Consortium (GHBMC). FE modeling was performed in LS-DYNA and LS-OPT (Livermore Software Technology Group) was used for ligament laxity optimization. Ordinate-based curve matching was used to minimize the mean squared error (MSE) between computed load-rotation curves and experimental load-rotation curves under flexion, extension, and axial rotation with pure moment loads from 0 to 3.5 Nm. Lateral bending was excluded from the optimization because the upper cervical spine was considered to be primarily responsible for flexion, extension, and axial rotation. Based on recommendations from the literature, four varying inputs representing laxity in select ligaments were optimized to minimize the MSE. Funding was provided by the Natural Sciences and Engineering Research Council of Canada as well as GHMBC. The present study was funded by the Natural Sciences and Engineering Research Council of Canada to support the work of one graduate student. There are no conflicts of interest to be reported. The MSE was reduced to 0.28 in the FE model with optimized ligament laxity compared with an MSE 0f 4.16 in the FE model without laxity. In all load cases, incorporating ligament laxity improved the agreement between the ROM of the FE model and the ROM of the experimental data. The ROM for axial rotation and extension was within one standard deviation of the experimental data. The ROM for flexion and lateral bending was outside one standard deviation of the experimental data, but a compromise was required to use one set of ligament laxity values to achieve a best fit to all load cases. Atlanto-occipital motion was compared as a ratio to overall ROM, and only in extension did the inclusion of ligament laxity not improve the agreement. After a Type II odontoid fracture was incorporated into the model, the increase in ROM was consistent with experimental data from the literature. The optimization approach used in this study provided values for ligament laxities that, when incorporated into the FE model, generally improved the ROM response when compared with experimental data. Successfully modeling a Type II odontoid fracture showcased the robustness of the FE model, which can now be used in future biomechanics studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. POD/DEIM reduced-order strategies for efficient four dimensional variational data assimilation

    NASA Astrophysics Data System (ADS)

    Ştefănescu, R.; Sandu, A.; Navon, I. M.

    2015-08-01

    This work studies reduced order modeling (ROM) approaches to speed up the solution of variational data assimilation problems with large scale nonlinear dynamical models. It is shown that a key requirement for a successful reduced order solution is that reduced order Karush-Kuhn-Tucker conditions accurately represent their full order counterparts. In particular, accurate reduced order approximations are needed for the forward and adjoint dynamical models, as well as for the reduced gradient. New strategies to construct reduced order based are developed for proper orthogonal decomposition (POD) ROM data assimilation using both Galerkin and Petrov-Galerkin projections. For the first time POD, tensorial POD, and discrete empirical interpolation method (DEIM) are employed to develop reduced data assimilation systems for a geophysical flow model, namely, the two dimensional shallow water equations. Numerical experiments confirm the theoretical framework for Galerkin projection. In the case of Petrov-Galerkin projection, stabilization strategies must be considered for the reduced order models. The new reduced order shallow water data assimilation system provides analyses similar to those produced by the full resolution data assimilation system in one tenth of the computational time.

  19. State estimation of spatio-temporal phenomena

    NASA Astrophysics Data System (ADS)

    Yu, Dan

    This dissertation addresses the state estimation problem of spatio-temporal phenomena which can be modeled by partial differential equations (PDEs), such as pollutant dispersion in the atmosphere. After discretizing the PDE, the dynamical system has a large number of degrees of freedom (DOF). State estimation using Kalman Filter (KF) is computationally intractable, and hence, a reduced order model (ROM) needs to be constructed first. Moreover, the nonlinear terms, external disturbances or unknown boundary conditions can be modeled as unknown inputs, which leads to an unknown input filtering problem. Furthermore, the performance of KF could be improved by placing sensors at feasible locations. Therefore, the sensor scheduling problem to place multiple mobile sensors is of interest. The first part of the dissertation focuses on model reduction for large scale systems with a large number of inputs/outputs. A commonly used model reduction algorithm, the balanced proper orthogonal decomposition (BPOD) algorithm, is not computationally tractable for large systems with a large number of inputs/outputs. Inspired by the BPOD and randomized algorithms, we propose a randomized proper orthogonal decomposition (RPOD) algorithm and a computationally optimal RPOD (RPOD*) algorithm, which construct an ROM to capture the input-output behaviour of the full order model, while reducing the computational cost of BPOD by orders of magnitude. It is demonstrated that the proposed RPOD* algorithm could construct the ROM in real-time, and the performance of the proposed algorithms on different advection-diffusion equations. Next, we consider the state estimation problem of linear discrete-time systems with unknown inputs which can be treated as a wide-sense stationary process with rational power spectral density, while no other prior information needs to be known. We propose an autoregressive (AR) model based unknown input realization technique which allows us to recover the input statistics from the output data by solving an appropriate least squares problem, then fit an AR model to the recovered input statistics and construct an innovations model of the unknown inputs using the eigensystem realization algorithm. The proposed algorithm outperforms the augmented two-stage Kalman Filter (ASKF) and the unbiased minimum-variance (UMV) algorithm are shown in several examples. Finally, we propose a framework to place multiple mobile sensors to optimize the long-term performance of KF in the estimation of the state of a PDE. The major challenges are that placing multiple sensors is an NP-hard problem, and the optimization problem is non-convex in general. In this dissertation, first, we construct an ROM using RPOD* algorithm, and then reduce the feasible sensor locations into a subset using the ROM. The Information Space Receding Horizon Control (I-RHC) approach and a modified Monte Carlo Tree Search (MCTS) approach are applied to solve the sensor scheduling problem using the subset. Various applications have been provided to demonstrate the performance of the proposed approach.

  20. Tomorrow's Online in Today's CD-ROM: Interfaces and Images.

    ERIC Educational Resources Information Center

    Jacso, Peter

    1994-01-01

    Considers the appropriateness of using CD-ROM versus online systems. Topics discussed include cost effectiveness; how current the information is; full-text capabilities; a variety of interfaces; graphical user interfaces on CD-ROM; and possibilities for image representations. (LRW)

  1. How to Purchase, Set Up, & Safeguard a CD-ROM Network.

    ERIC Educational Resources Information Center

    Almquist, Arne J.

    1996-01-01

    Presents an overview of the hardware and software required to network CD-ROMs in schools. Topics include network infrastructures, networking software, file server-based systems, CD-ROM servers, vendors of network components, workstations, network utilities, and network management. (LRW)

  2. Adding-point strategy for reduced-order hypersonic aerothermodynamics modeling based on fuzzy clustering

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Liu, Li; Zhou, Sida; Yue, Zhenjiang

    2016-09-01

    Reduced order models(ROMs) based on the snapshots on the CFD high-fidelity simulations have been paid great attention recently due to their capability of capturing the features of the complex geometries and flow configurations. To improve the efficiency and precision of the ROMs, it is indispensable to add extra sampling points to the initial snapshots, since the number of sampling points to achieve an adequately accurate ROM is generally unknown in prior, but a large number of initial sampling points reduces the parsimony of the ROMs. A fuzzy-clustering-based adding-point strategy is proposed and the fuzzy clustering acts an indicator of the region in which the precision of ROMs is relatively low. The proposed method is applied to construct the ROMs for the benchmark mathematical examples and a numerical example of hypersonic aerothermodynamics prediction for a typical control surface. The proposed method can achieve a 34.5% improvement on the efficiency than the estimated mean squared error prediction algorithm and shows same-level prediction accuracy.

  3. 4D-Var Developement at GMAO

    NASA Technical Reports Server (NTRS)

    Pelc, Joanna S.; Todling, Ricardo; Akkraoui, Amal El

    2014-01-01

    The Global Modeling and Assimilation Offce (GMAO) is currently using an IAU-based 3D-Var data assimilation system. GMAO has been experimenting with a 3D-Var-hybrid version of its data assimilation system (DAS) for over a year now, which will soon become operational and it will rapidly progress toward a 4D-EnVar. Concurrently, the machinery to exercise traditional 4DVar is in place and it is desirable to have a comparison of the traditional 4D approach with the other available options, and evaluate their performance in the Goddard Earth Observing System (GEOS) DAS. This work will also explore the possibility for constructing a reduced order model (ROM) to make traditional 4D-Var computationally attractive for increasing model resolutions. Part of the research on ROM will be to search for a suitably acceptable space to carry on the corresponding reduction. This poster illustrates how the IAU-based 4D-Var assimilation compares with our currently used IAU-based 3D-Var.

  4. A Trichomonas vaginalis Rhomboid Protease and Its Substrate Modulate Parasite Attachment and Cytolysis of Host Cells

    PubMed Central

    Riestra, Angelica M.; Gandhi, Shiv; Sweredoski, Michael J.; Moradian, Annie; Hess, Sonja; Urban, Sinisa; Johnson, Patricia J.

    2015-01-01

    Trichomonas vaginalis is an extracellular eukaryotic parasite that causes the most common, non-viral sexually transmitted infection worldwide. Although disease burden is high, molecular mechanisms underlying T. vaginalis pathogenesis are poorly understood. Here, we identify a family of putative T. vaginalis rhomboid proteases and demonstrate catalytic activity for two, TvROM1 and TvROM3, using a heterologous cell cleavage assay. The two T. vaginalis intramembrane serine proteases display different subcellular localization and substrate specificities. TvROM1 is a cell surface membrane protein and cleaves atypical model rhomboid protease substrates, whereas TvROM3 appears to localize to the Golgi apparatus and recognizes a typical model substrate. To identify TvROM substrates, we interrogated the T. vaginalis surface proteome using both quantitative proteomic and bioinformatic approaches. Of the nine candidates identified, TVAG_166850 and TVAG_280090 were shown to be cleaved by TvROM1. Comparison of amino acid residues surrounding the predicted cleavage sites of TvROM1 substrates revealed a preference for small amino acids in the predicted transmembrane domain. Over-expression of TvROM1 increased attachment to and cytolysis of host ectocervical cells. Similarly, mutations that block the cleavage of a TvROM1 substrate lead to its accumulation on the cell surface and increased parasite adherence to host cells. Together, these data indicate a role for TvROM1 and its substrate(s) in modulating attachment to and lysis of host cells, which are key processes in T. vaginalis pathogenesis. PMID:26684303

  5. Projection-Based Reduced Order Modeling for Spacecraft Thermal Analysis

    NASA Technical Reports Server (NTRS)

    Qian, Jing; Wang, Yi; Song, Hongjun; Pant, Kapil; Peabody, Hume; Ku, Jentung; Butler, Charles D.

    2015-01-01

    This paper presents a mathematically rigorous, subspace projection-based reduced order modeling (ROM) methodology and an integrated framework to automatically generate reduced order models for spacecraft thermal analysis. Two key steps in the reduced order modeling procedure are described: (1) the acquisition of a full-scale spacecraft model in the ordinary differential equation (ODE) and differential algebraic equation (DAE) form to resolve its dynamic thermal behavior; and (2) the ROM to markedly reduce the dimension of the full-scale model. Specifically, proper orthogonal decomposition (POD) in conjunction with discrete empirical interpolation method (DEIM) and trajectory piece-wise linear (TPWL) methods are developed to address the strong nonlinear thermal effects due to coupled conductive and radiative heat transfer in the spacecraft environment. Case studies using NASA-relevant satellite models are undertaken to verify the capability and to assess the computational performance of the ROM technique in terms of speed-up and error relative to the full-scale model. ROM exhibits excellent agreement in spatiotemporal thermal profiles (<0.5% relative error in pertinent time scales) along with salient computational acceleration (up to two orders of magnitude speed-up) over the full-scale analysis. These findings establish the feasibility of ROM to perform rational and computationally affordable thermal analysis, develop reliable thermal control strategies for spacecraft, and greatly reduce the development cycle times and costs.

  6. A Reduced Order Model for Whole-Chip Thermal Analysis of Microfluidic Lab-on-a-Chip Systems

    PubMed Central

    Wang, Yi; Song, Hongjun; Pant, Kapil

    2013-01-01

    This paper presents a Krylov subspace projection-based Reduced Order Model (ROM) for whole microfluidic chip thermal analysis, including conjugate heat transfer. Two key steps in the reduced order modeling procedure are described in detail, including (1) the acquisition of a 3D full-scale computational model in the state-space form to capture the dynamic thermal behavior of the entire microfluidic chip; and (2) the model order reduction using the Block Arnoldi algorithm to markedly lower the dimension of the full-scale model. Case studies using practically relevant thermal microfluidic chip are undertaken to establish the capability and to evaluate the computational performance of the reduced order modeling technique. The ROM is compared against the full-scale model and exhibits good agreement in spatiotemporal thermal profiles (<0.5% relative error in pertinent time scales) and over three orders-of-magnitude acceleration in computational speed. The salient model reusability and real-time simulation capability renders it amenable for operational optimization and in-line thermal control and management of microfluidic systems and devices. PMID:24443647

  7. Analysis of reactive oxygen metabolites (ROMs) after cardiovascular surgery as a marker of oxidative stress.

    PubMed

    Kanaoka, Yuji; Inagaki, Ei-ichirou; Hamanaka, Souhei; Masaki, Hisao; Tanemoto, Kazuo

    2010-10-01

    The transient systemic low perfusion that occurs during cardiovascular surgery leads to oxidative stress and the production of free radicals. A systemic increase of various markers of oxidative stress has been shown to occur during cardiopulmonary bypass (CPB). However, these markers have not been adequately evaluated because they seem to be reactive and short-lived. Here, oxidative stress was measured using the free radical analytical system (FRAS 4) assessing the derivatives of reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP). Blood samples were taken from 21 patients undergoing elective cardiovascular surgery. CPB was used in 15 patients, and abdominal aortic aneurysm (AAA) surgery without CPB was performed in 6. Measurements of d-ROMs and BAP were taken before surgery, 1 day, 1 week, and 2 weeks after surgery, and oxidative stress was evaluated. The d-ROM level increased gradually after cardiovascular surgery up to 2 weeks. Over time, the d-ROM level after surgery involving CPB became higher than that after AAA surgery. This difference reached statistical significance at 1 week and lasted to 2 weeks. The prolongation of CPB was prone to elevate the d-ROM level whereas the duration of the aortic clamp in AAA surgery had no relation to the d-ROM level. The BAP was also elevated after surgery, and was positively correlated with the level of d-ROMs. In this study, patients who underwent cardiovascular surgery involving CPB had significant oxidative damage. The production of ROMs was shown to depend on the duration of CPB. Damage can be reduced if CPB is avoided. When CPB must be used, shortening the CPB time may be effective in reducing oxidative stress.

  8. Officer Computer Utilization Report

    DTIC Science & Technology

    1992-03-01

    Shipboard Non-tactical ADP Program (SNAP),Navy Intelligence Processing System (NIPS), Retail Operation Management (ROM)). Mainframe - An extremely...ADP Program (SNAP), Navy Intelligence Processing System (NIPS), Retail Operation Management (ROM), etc.) @0230@6 7 7. Technical/tactical systems (e.g

  9. A Deep Learning based Approach to Reduced Order Modeling of Fluids using LSTM Neural Networks

    NASA Astrophysics Data System (ADS)

    Mohan, Arvind; Gaitonde, Datta

    2017-11-01

    Reduced Order Modeling (ROM) can be used as surrogates to prohibitively expensive simulations to model flow behavior for long time periods. ROM is predicated on extracting dominant spatio-temporal features of the flow from CFD or experimental datasets. We explore ROM development with a deep learning approach, which comprises of learning functional relationships between different variables in large datasets for predictive modeling. Although deep learning and related artificial intelligence based predictive modeling techniques have shown varied success in other fields, such approaches are in their initial stages of application to fluid dynamics. Here, we explore the application of the Long Short Term Memory (LSTM) neural network to sequential data, specifically to predict the time coefficients of Proper Orthogonal Decomposition (POD) modes of the flow for future timesteps, by training it on data at previous timesteps. The approach is demonstrated by constructing ROMs of several canonical flows. Additionally, we show that statistical estimates of stationarity in the training data can indicate a priori how amenable a given flow-field is to this approach. Finally, the potential and limitations of deep learning based ROM approaches will be elucidated and further developments discussed.

  10. Exploring the use of Routine Outcome Monitoring in the treatment of patients with a psychotic disorder.

    PubMed

    Tasma, M; Liemburg, E J; Knegtering, H; Delespaul, P A E G; Boonstra, A; Castelein, S

    2017-05-01

    Routine Outcome Monitoring (ROM) has become part of the treatment process in mental health care. However, studies have indicated that few clinicians in psychiatry use the outcome of ROM in their daily work. The aim of this study was to explore the degree of ROM use in clinical practice as well as the explanatory factors of this use. In the Northern Netherlands, a ROM-protocol (ROM-Phamous) for patients with a psychotic disorder has been implemented. To establish the degree of ROM-Phamous use in clinical practice, the ROM results of patients (n=204) were compared to the treatment goals formulated in their treatment plans. To investigate factors that might influence ROM use, clinicians (n=32) were asked to fill out a questionnaire about ROM-Phamous. Care domains that were problematic according to the ROM-Phamous results were mentioned in the treatment plan in 28% of cases on average (range 5-45%). The use of ROM-Phamous in the treatment process varies considerably among clinicians. Most of the clinicians find ROM-Phamous both useful and important for good clinical practice. In contrast, the perceived ease-of-use is low and most clinicians report insufficient time to use ROM-Phamous. More frequent ROM use should be facilitated in clinicians. This could be achieved by improving the fit with clinical routines and the ease-of-use of ROM systems. It is important for all stakeholders to invest in integrating ROM in clinical practice. Eventually, this might improve the diagnostics and treatment of patients in mental health care. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. REGIONAL OXIDANT MODEL (ROM) USER'S GUIDE, PART 3: THE CORE MODEL

    EPA Science Inventory

    The Regional Oxidant Model (ROM) determines hourly concentrations and fates of zone and 34 other chemical species over a scale of 1000 km x 1000 km for ozone "episodes" of up to one month's duration. he model structure, based on phenomenological concepts, consists of 3 1/2 layers...

  12. A 4DVAR System for the Navy Coastal Ocean Model. Part 1: System Description and Assimilation of Synthetic Observations in Monterey Bay

    DTIC Science & Technology

    2014-06-01

    Shulman et al. 2007 ); and river discharge (Morey et al. 2003) and river plume modeling (Liu et al. 2009); and in modeling air–sea interactions through...coupling with atmospheric models (Pullen et al. 2006, 2007 ). Other applications include particle transport (Haza et al. 2007 ; Schroeder et al. 2011...consortium assimila- tion experiments ( Stammer et al. 2002), and a similar sys- tem was built for the Regional Ocean Model System (ROMS;Moore et al

  13. Reduced Order Modeling of Combustion Instability in a Gas Turbine Model Combustor

    NASA Astrophysics Data System (ADS)

    Arnold-Medabalimi, Nicholas; Huang, Cheng; Duraisamy, Karthik

    2017-11-01

    Hydrocarbon fuel based propulsion systems are expected to remain relevant in aerospace vehicles for the foreseeable future. Design of these devices is complicated by combustion instabilities. The capability to model and predict these effects at reduced computational cost is a requirement for both design and control of these devices. This work focuses on computational studies on a dual swirl model gas turbine combustor in the context of reduced order model development. Full fidelity simulations are performed utilizing URANS and Hybrid RANS-LES with finite rate chemistry. Following this, data decomposition techniques are used to extract a reduced basis representation of the unsteady flow field. These bases are first used to identify sensor locations to guide experimental interrogations and controller feedback. Following this, initial results on developing a control-oriented reduced order model (ROM) will be presented. The capability of the ROM will be further assessed based on different operating conditions and geometric configurations.

  14. [Research on the range of motion measurement system for spine based on LabVIEW image processing technology].

    PubMed

    Li, Xiaofang; Deng, Linhong; Lu, Hu; He, Bin

    2014-08-01

    A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.

  15. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  16. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  17. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  18. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  19. CD-ROM and Libraries.

    ERIC Educational Resources Information Center

    Murphy, Brower

    1985-01-01

    The Compact Disc-Read Only Memory (CD-ROM) data format is explained and illustrated, noting current and potential applications. The "5-inch" compact laserdisc is described and photographs of an IBM PC/Hitachi CD-ROM system adopted by Library Corporation to support its MARC database--BiblioFile--are presented. Screen displays for…

  20. CD-ROM versus Online.

    ERIC Educational Resources Information Center

    Wiedemer, John David; Boelio, David B.

    1995-01-01

    Compares compact discs (CD-ROMs) and online services in terms of cost of information delivery; system advantages and disadvantages; future possibilities; and role in the National Information Infrastructure. Analysis reveals that CD-ROMs have the lowest information delivery cost and are endorsed by the marketplace as a cost-effective way to deliver…

  1. Serials Information on CD-ROM: A Reference Perspective.

    ERIC Educational Resources Information Center

    Karch, Linda S.

    1990-01-01

    Describes Ulrich's PLUS (a CD-ROM version of Ulrich's serials directories) and EBSCO's CD-ROM version of "The Serials Directory," and compares the two in terms of their use as reference tools. Areas discussed include database content, user aids, system features, search features, and a comparison of search results. Equipment requirements…

  2. Enhancing Your CD-ROM Services with Signage Systems.

    ERIC Educational Resources Information Center

    Ekhaml, Leticia

    1994-01-01

    Describes how to use effective signage, or visual guidance, for more efficient use of CD-ROM technology in elementary and secondary school library media centers. Setting CD-ROM policies and procedures is considered; the use of posters, brochures, flowcharts, and other formats is discussed; and examples are included. (LRW)

  3. Reduced-order modeling with sparse polynomial chaos expansion and dimension reduction for evaluating the impact of CO2 and brine leakage on groundwater

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Zheng, L.; Pau, G. S. H.

    2016-12-01

    A careful assessment of the risk associated with geologic CO2 storage is critical to the deployment of large-scale storage projects. While numerical modeling is an indispensable tool for risk assessment, there has been increasing need in considering and addressing uncertainties in the numerical models. However, uncertainty analyses have been significantly hindered by the computational complexity of the model. As a remedy, reduced-order models (ROM), which serve as computationally efficient surrogates for high-fidelity models (HFM), have been employed. The ROM is constructed at the expense of an initial set of HFM simulations, and afterwards can be relied upon to predict the model output values at minimal cost. The ROM presented here is part of National Risk Assessment Program (NRAP) and intends to predict the water quality change in groundwater in response to hypothetical CO2 and brine leakage. The HFM based on which the ROM is derived is a multiphase flow and reactive transport model, with 3-D heterogeneous flow field and complex chemical reactions including aqueous complexation, mineral dissolution/precipitation, adsorption/desorption via surface complexation and cation exchange. Reduced-order modeling techniques based on polynomial basis expansion, such as polynomial chaos expansion (PCE), are widely used in the literature. However, the accuracy of such ROMs can be affected by the sparse structure of the coefficients of the expansion. Failing to identify vanishing polynomial coefficients introduces unnecessary sampling errors, the accumulation of which deteriorates the accuracy of the ROMs. To address this issue, we treat the PCE as a sparse Bayesian learning (SBL) problem, and the sparsity is obtained by detecting and including only the non-zero PCE coefficients one at a time by iteratively selecting the most contributing coefficients. The computational complexity due to predicting the entire 3-D concentration fields is further mitigated by a dimension reduction procedure-proper orthogonal decomposition (POD). Our numerical results show that utilizing the sparse structure and POD significantly enhances the accuracy and efficiency of the ROMs, laying the basis for further analyses that necessitate a large number of model simulations.

  4. IAS Mesoscale Surface Circulation Observed Through Satellite Altimetry and its Influence in a Small Scale, Coastal Domain, Studied with a ROMS Model of the Cariaco Basin.

    NASA Astrophysics Data System (ADS)

    Alvera-Azcarate, A.; Barth, A.; Virmani, J. I.; Weisberg, R. H.

    2007-05-01

    The Intra-Americas Sea (IAS) surface circulation is characterized by large scale currents. The Caribbean current, which originates in the Lesser Antilles, travels westwards through the Caribbean Sea and eastern Mexico and passes through the Gulf of Mexico to finally form the Gulf Stream. This complex system of currents is also characterized by a high mesoscale variability, such as eddies and meanders. The objectives of this work are twofold: first, the multi-scale surface circulation of the IAS is described using satellite altimetry. The topographic influence of the different basins forming the IAS, the characteristic time and spatial scales, and the time variability of the surface circulation will be addressed. The second objective is to analyze the influence of this large scale circulation on a small scale coastal domain with a ROMS-based model of the Cariaco basin (Venezuela). Cariaco is a deep (1400 m), semi-enclosed basin connected to the open ocean by two shallow channels (Tortuga and Centinela Channels). Its connection with the open sea, and therefore the ventilation of the basin, occurs in the surface layers. The Cariaco ROMS model will be used to study the exchanges of mass, heat and salt through the channels. A 1/60 degree ROMS model nested in the global 1/12 degree HYCOM model from the Naval Research Laboratory will be used for this study. In addition, a series of observations (satellite altimetry and in situ temperature, salinity and velocity data), will be used to assess the influence of the Caribbean circulation on the basin.

  5. Tropical Ocean Global Atmosphere (TOGA) Meteorological and Oceanographic Data Sets for 1985 and 1986

    NASA Technical Reports Server (NTRS)

    Halpern, D.; Ashby, H.; Finch, C.; Smith, E.; Robles, J.

    1990-01-01

    The Tropical Ocean Global Atmosphere (TOGA) Program is a component of the World Meteorological Organization (WMO)/International Council of Scientific Unions (ICSU) World Climate Research Program (WCRP). One of the objectives of TOGA, which began in 1985, is to determine the limits of predictability of monthly mean sea surface temperature variations in tropical regions. The TOGA program created a raison d'etre for an explosive growth of the tropical ocean observing system and a substantial improvement in numerical simulations from atmospheric and oceanic general circulation models. Institutions located throughout the world are involved in the TOGA-distributed active data archive system. The diverse TOGA data sets for 1985 and 1986, including results from general circulation models, are included on a CD-ROM. Variables on the CD-ROM are barometric pressure, surface air temperature, dewpoint temperature Cartesian components of surface wind, surface sensible and latent heat fluxes,Cartesian components of surface wind stress and of an index of surface wind stress, sea level, sea surface temperature, and depth profiles of temperature and current in the upper ocean. Some data sets are global in extent, some are regional and cover portions of an ocean basin. Data on the CD-ROM can be extracted with an Apple Macintosh or an IBM PC.

  6. Development of a General Form CO 2 and Brine Flux Input Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mansoor, K.; Sun, Y.; Carroll, S.

    2014-08-01

    The National Risk Assessment Partnership (NRAP) project is developing a science-based toolset for the quantitative analysis of the potential risks associated with changes in groundwater chemistry from CO 2 injection. In order to address uncertainty probabilistically, NRAP is developing efficient, reduced-order models (ROMs) as part of its approach. These ROMs are built from detailed, physics-based process models to provide confidence in the predictions over a range of conditions. The ROMs are designed to reproduce accurately the predictions from the computationally intensive process models at a fraction of the computational time, thereby allowing the utilization of Monte Carlo methods to probemore » variability in key parameters. This report presents the procedures used to develop a generalized model for CO 2 and brine leakage fluxes based on the output of a numerical wellbore simulation. The resulting generalized parameters and ranges reported here will be used for the development of third-generation groundwater ROMs.« less

  7. Nonlinear model predictive control for chemical looping process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, Abhinaya; Lei, Hao; Lou, Xinsheng

    A control system for optimizing a chemical looping ("CL") plant includes a reduced order mathematical model ("ROM") that is designed by eliminating mathematical terms that have minimal effect on the outcome. A non-linear optimizer provides various inputs to the ROM and monitors the outputs to determine the optimum inputs that are then provided to the CL plant. An estimator estimates the values of various internal state variables of the CL plant. The system has one structure adapted to control a CL plant that only provides pressure measurements in the CL loops A and B, a second structure adapted to amore » CL plant that provides pressure measurements and solid levels in both loops A, and B, and a third structure adapted to control a CL plant that provides full information on internal state variables. A final structure provides a neural network NMPC controller to control operation of loops A and B.« less

  8. Pain sensitivity and torque used during measurement predicts change in range of motion at the knee.

    PubMed

    Bishop, Mark D; George, Steven Z

    2017-01-01

    To determine the extent to which changes in knee range of motion (ROM) after a stretching program are related to sensory factors at the time of testing and the amount of force used during the measurement of ROM, rather than changes in soft-tissue properties. Randomized, single-blind design. Participants were randomly assigned to a control or stretching group. Research laboratory. Forty-four healthy volunteers (22.8±2.8 years of age; 23 men). The stretching group undertook static stretching twice a day for 8 weeks. The control group continued with routine activity, but was discouraged from starting a flexibility program. ROM and tissue extensibility was assessed using a Biodex3 dynamometer, and ratings of thermal pain were collected at baseline and at 4 and 8 weeks by an examiner blinded to group assignment. Multilevel modeling was used to examine predictors of ROM across time. The stretching group showed a 6% increase, and the control group had a 2% increase, in ROM over the 8-week program. However, when fixed and random effects were tested in a complete model, the group assignment was not significant. End-point torque during ROM testing ( p =0.021) and the ratings in response to thermal testing ( p <0.001) were significant, however. ROM measured in a testing session was not predicted by assignment to a stretching program. Rather, ROM was predicted by the ratings of thermal stimuli and the peak torque used to apply the stretch.

  9. Reflections on CD-ROM: Bridging the Gap between Technology and Purpose.

    ERIC Educational Resources Information Center

    Saviers, Shannon Smith

    1987-01-01

    Provides a technological overview of CD-ROM (Compact Disc-Read Only Memory), an optically-based medium for data storage offering large storage capacity, computer-based delivery system, read-only medium, and economic mass production. CD-ROM database attributes appropriate for information delivery are also reviewed, including large database size,…

  10. CMOS array design automation techniques

    NASA Technical Reports Server (NTRS)

    Lombardi, T.; Feller, A.

    1976-01-01

    The design considerations and the circuit development for a 4096-bit CMOS SOS ROM chip, the ATL078 are described. Organization of the ATL078 is 512 words by 8 bits. The ROM was designed to be programmable either at the metal mask level or by a directed laser beam after processing. The development of a 4K CMOS SOS ROM fills a void left by available ROM chip types, and makes the design of a totally major high speed system more realizable.

  11. POD/DEIM reduced-order strategies for efficient four dimensional variational data assimilation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ştefănescu, R., E-mail: rstefane@vt.edu; Sandu, A., E-mail: sandu@cs.vt.edu; Navon, I.M., E-mail: inavon@fsu.edu

    2015-08-15

    This work studies reduced order modeling (ROM) approaches to speed up the solution of variational data assimilation problems with large scale nonlinear dynamical models. It is shown that a key requirement for a successful reduced order solution is that reduced order Karush–Kuhn–Tucker conditions accurately represent their full order counterparts. In particular, accurate reduced order approximations are needed for the forward and adjoint dynamical models, as well as for the reduced gradient. New strategies to construct reduced order based are developed for proper orthogonal decomposition (POD) ROM data assimilation using both Galerkin and Petrov–Galerkin projections. For the first time POD, tensorialmore » POD, and discrete empirical interpolation method (DEIM) are employed to develop reduced data assimilation systems for a geophysical flow model, namely, the two dimensional shallow water equations. Numerical experiments confirm the theoretical framework for Galerkin projection. In the case of Petrov–Galerkin projection, stabilization strategies must be considered for the reduced order models. The new reduced order shallow water data assimilation system provides analyses similar to those produced by the full resolution data assimilation system in one tenth of the computational time.« less

  12. Development of a three-dimensional variational data assimilation system for the Seto Island Sea, Japan

    NASA Astrophysics Data System (ADS)

    Kurosawa, K.; Uchiyama, Y.

    2016-12-01

    By optimally combined ocean models with observation data, numerical oceanic reanalysis and forecast systems allow us to predict the ocean more precisely. In general, data assimilation is exploited to prepare the initial condition for the forecast. This technique has widely been employed in atmospheric prediction, whereas oceanic prediction lags behind weather forecast. Accurate oceanic prediction systems have been demanded for operational purposes such as for fisheries, vessel navigation, marine construction, offshore platform management, marine monitoring, etc. In particular, in crowded harbors and estuaries including the Seto Inland Sea (SIS), Japan, data assimilation has seldom been adapted because data from satellites and Argo floats essential to successful oceanic predictions is desperately limited. In addition, although static data assimilation, typically three-dimensional variational data assimilation (3DVAR), is computationally cheap and statistically optimal, but is not physically balanced. For instance, 3DVAR is known to modify velocity and density fields merely mathematically, yet it does not adequately consider quasi-geostrophic balance, which is generally true in most cases. In the present study, we develop a 3DVAR system for Regional Oceanic Modeling Systems (ROMS) and apply to the high-resolution SIS model in a double nested configuration (Kosako et al., 2015). The SIS is the largest estuary in Japan with a number of autonomous in-situ monitoring of vertical profiles of temperature and salinity, tens of tidal gages, along with continuous surface current measurement using HF radars. We first present a theoretical framework of the 3DVAR algorithm by considering geostrophic and thermal-wind balance to find plausible relationships among physical variables to avoid undesirable modifications. Subsequently, the developed 3DVAR is coupled with the SIS ROMS model to compare the model outcomes against some observation data. The 3DVAR ROMS model for the SIS performs much better than the SIS model without assimilation and demonstrates good model skills with reproducing quite complex flows in the SIS because of its complicated topography with more than 3,000 islands in there. Furthermore we will share technical difficulties encountered during the experiment.

  13. Galerkin Method for Nonlinear Dynamics

    NASA Astrophysics Data System (ADS)

    Noack, Bernd R.; Schlegel, Michael; Morzynski, Marek; Tadmor, Gilead

    A Galerkin method is presented for control-oriented reduced-order models (ROM). This method generalizes linear approaches elaborated by M. Morzyński et al. for the nonlinear Navier-Stokes equation. These ROM are used as plants for control design in the chapters by G. Tadmor et al., S. Siegel, and R. King in this volume. Focus is placed on empirical ROM which compress flow data in the proper orthogonal decomposition (POD). The chapter shall provide a complete description for construction of straight-forward ROM as well as the physical understanding and teste

  14. Fundamental Insights into Combustion Instability Predictions in Aerospace Propulsion

    NASA Astrophysics Data System (ADS)

    Huang, Cheng

    Integrated multi-fidelity modeling has been performed for combustion instability in aerospace propulsion, which includes two levels of analysis: first, computational fluid dynamics (CFD) using hybrid RANS/LES simulations for underlying physics investigations (high-fidelity modeling); second, modal decomposition techniques for diagnostics (analysis & validation); third, development of flame response model using model reduction techniques for practical design applications (low-order model). For the high-fidelity modeling, the relevant CFD code development work is moving towards combustion instability prediction for liquid propulsion system. A laboratory-scale single-element lean direct injection (LDI) gas turbine combustor is used for configuration that produces self-excited combustion instability. The model gas turbine combustor is featured with an air inlet section, air plenum, swirler-venturi-injector assembly, combustion chamber, and exit nozzle. The combustor uses liquid fuel (Jet-A/FT-SPK) and heated air up to 800K. Combustion dynamics investigations are performed with the same geometry and operating conditions concurrently between the experiment and computation at both high (φ=0.6) and low (φ=0.36) equivalence ratios. The simulation is able to reach reasonable agreement with experiment measurements in terms of the pressure signal. Computational analyses are also performed using an acoustically-open geometry to investigate the characteristic hydrodynamics in the combustor with both constant and perturbed inlet mass flow rates. Two hydrodynamic modes are identified by using Dynamic Mode Decomposition (DMD) analysis: Vortex Breakdown Bubble (VBB) and swirling modes. Following that, the closed geometry simulation results are analyzed in three steps. In step one, a detailed cycle analysis shows two physically important couplings in the combustor: first, the acoustic compression enhances the spray drop breakup and vaporization, and generates more gaseous fuel for reaction; second, the acoustic compression couples with the unsteady hydrodynamics found in the open-geometry simulation, enhances the fuel/air mixing, and triggers a large amount of heat addition. In step two, a modal analysis using DMD extracts the dynamic features of important modes in the combustor, and identifies the presence of Precessing Vortex Core (PVC) mode and its nonlinear interactions with acoustic modes. Moreover, the DMD analysis helps to establish the couplings between the hydrodynamics and acoustics in terms of frequencies. In step 3, Rayleigh index analysis provides a quantitative assessment of acoustics/combustion couplings and identifies local regions for instability driving/damping. Two modal decomposition techniques, Proper Orthogonal Decomposition (POD) and Dynamic Mode Decomposition (DMD), are assessed in terms of their capabilities in extracting important information from the original simulation dataset and in validating the computational results using the experiment measurement. A POD analysis provides a series of modes with decreasing energy content and it offers an efficient and optimized way to represent a large dataset. The frequency-based DMD technique provides modes that correspond to all single frequencies. For the low-order modeling, fundamental aspects are examined to study necessary conditions, criteria and approaches to develop a reduced-order model (ROM) that is able to represent generic combustion/flame responses, which then can be used in an engineering level tool to provide efficient predictions of combustion instability for practical design applications. Explorations are focused on model reduction techniques by using the so-called POD/Galerkin method. The method uses the numerical solutions of the model equations as the database for building a set of POD eigen-bases. Specifically, the numerical solutions are calculated by perturbing quantities of interest such as the inlet conditions. The POD-derived eigen-bases are, in turn, used in conjunction with a Galerkin procedure to reduce the governing partial differential equation to an ordinary differential equation, which constitutes the ROM. Once the ROM is established, it can then be used as a lower-order test-bed to predict detailed results within certain parametric ranges at a fraction of the cost of solving the full governing equations. A detailed assessment is performed on the method in two parts. In part one, a one-dimensional scalar reaction-advection model equation is used for fundamental investigations, which include verification of the POD eigen-basis calculation and of the ROM development procedure. Moreover, certain criteria during ROM development are established: 1. a necessary number of POD modes that should be included to guarantee a stable ROM; 2. the need for the numerical discretization scheme to be consistent between the original CFD and the developed ROM. Furthermore, the predictive capabilities of the resulting ROM are evaluated to test its limits and to validate the values of applying broadband forcing in improving the ROM performance. In part two, the exploration is extended to a vector system of equations. Using the one-dimensional Euler equation is used as a model equation. A numerical stability issue is identified during the ROM development, the cause of which is further studied and attributed to the normalization methods implemented to generate coupled POD eigen-bases for vector variables. (Abstract shortened by UMI.).

  15. Evaluation of a computational model to predict elbow range of motion

    PubMed Central

    Nishiwaki, Masao; Johnson, James A.; King, Graham J. W.; Athwal, George S.

    2014-01-01

    Computer models capable of predicting elbow flexion and extension range of motion (ROM) limits would be useful for assisting surgeons in improving the outcomes of surgical treatment of patients with elbow contractures. A simple and robust computer-based model was developed that predicts elbow joint ROM using bone geometries calculated from computed tomography image data. The model assumes a hinge-like flexion-extension axis, and that elbow passive ROM limits can be based on terminal bony impingement. The model was validated against experimental results with a cadaveric specimen, and was able to predict the flexion and extension limits of the intact joint to 0° and 3°, respectively. The model was also able to predict the flexion and extension limits to 1° and 2°, respectively, when simulated osteophytes were inserted into the joint. Future studies based on this approach will be used for the prediction of elbow flexion-extension ROM in patients with primary osteoarthritis to help identify motion-limiting hypertrophic osteophytes, and will eventually permit real-time computer-assisted navigated excisions. PMID:24841799

  16. "Let's Talk about Sex": Pilot Study of an Interactive CD-ROM to Prevent HIV/STIS in Female Adolescents

    ERIC Educational Resources Information Center

    Ito, Kristin E.; Kalyanaraman, Sri; Ford, Carol A.; Brown, Jane D.; Miller, William C.

    2008-01-01

    The purpose of this study was to develop and pilot-test an interactive CD-ROM aimed at the prevention of sexually transmitted infections (STIs) in female adolescents. The CD-ROM includes prevention information, models skills for negotiating abstinence and consistent condom use, teaches media literacy, and allows the user to choose a culturally…

  17. International journal of computational fluid dynamics real-time prediction of unsteady flow based on POD reduced-order model and particle filter

    NASA Astrophysics Data System (ADS)

    Kikuchi, Ryota; Misaka, Takashi; Obayashi, Shigeru

    2016-04-01

    An integrated method consisting of a proper orthogonal decomposition (POD)-based reduced-order model (ROM) and a particle filter (PF) is proposed for real-time prediction of an unsteady flow field. The proposed method is validated using identical twin experiments of an unsteady flow field around a circular cylinder for Reynolds numbers of 100 and 1000. In this study, a PF is employed (ROM-PF) to modify the temporal coefficient of the ROM based on observation data because the prediction capability of the ROM alone is limited due to the stability issue. The proposed method reproduces the unsteady flow field several orders faster than a reference numerical simulation based on Navier-Stokes equations. Furthermore, the effects of parameters, related to observation and simulation, on the prediction accuracy are studied. Most of the energy modes of the unsteady flow field are captured, and it is possible to stably predict the long-term evolution with ROM-PF.

  18. Hybrid Reduced Order Modeling Algorithms for Reactor Physics Calculations

    NASA Astrophysics Data System (ADS)

    Bang, Youngsuk

    Reduced order modeling (ROM) has been recognized as an indispensable approach when the engineering analysis requires many executions of high fidelity simulation codes. Examples of such engineering analyses in nuclear reactor core calculations, representing the focus of this dissertation, include the functionalization of the homogenized few-group cross-sections in terms of the various core conditions, e.g. burn-up, fuel enrichment, temperature, etc. This is done via assembly calculations which are executed many times to generate the required functionalization for use in the downstream core calculations. Other examples are sensitivity analysis used to determine important core attribute variations due to input parameter variations, and uncertainty quantification employed to estimate core attribute uncertainties originating from input parameter uncertainties. ROM constructs a surrogate model with quantifiable accuracy which can replace the original code for subsequent engineering analysis calculations. This is achieved by reducing the effective dimensionality of the input parameter, the state variable, or the output response spaces, by projection onto the so-called active subspaces. Confining the variations to the active subspace allows one to construct an ROM model of reduced complexity which can be solved more efficiently. This dissertation introduces a new algorithm to render reduction with the reduction errors bounded based on a user-defined error tolerance which represents the main challenge of existing ROM techniques. Bounding the error is the key to ensuring that the constructed ROM models are robust for all possible applications. Providing such error bounds represents one of the algorithmic contributions of this dissertation to the ROM state-of-the-art. Recognizing that ROM techniques have been developed to render reduction at different levels, e.g. the input parameter space, the state space, and the response space, this dissertation offers a set of novel hybrid ROM algorithms which can be readily integrated into existing methods and offer higher computational efficiency and defendable accuracy of the reduced models. For example, the snapshots ROM algorithm is hybridized with the range finding algorithm to render reduction in the state space, e.g. the flux in reactor calculations. In another implementation, the perturbation theory used to calculate first order derivatives of responses with respect to parameters is hybridized with a forward sensitivity analysis approach to render reduction in the parameter space. Reduction at the state and parameter spaces can be combined to render further reduction at the interface between different physics codes in a multi-physics model with the accuracy quantified in a similar manner to the single physics case. Although the proposed algorithms are generic in nature, we focus here on radiation transport models used in support of the design and analysis of nuclear reactor cores. In particular, we focus on replacing the traditional assembly calculations by ROM models to facilitate the generation of homogenized cross-sections for downstream core calculations. The implication is that assembly calculations could be done instantaneously therefore precluding the need for the expensive evaluation of the few-group cross-sections for all possible core conditions. Given the generic natures of the algorithms, we make an effort to introduce the material in a general form to allow non-nuclear engineers to benefit from this work.

  19. Usability evaluation of a web-based support system for people with a schizophrenia diagnosis.

    PubMed

    van der Krieke, Lian; Emerencia, Ando C; Aiello, Marco; Sytema, Sjoerd

    2012-02-06

    Routine Outcome Monitoring (ROM) is a systematic way of assessing service users' health conditions for the purpose of better aiding their care. ROM consists of various measures used to assess a service user's physical, psychological, and social condition. While ROM is becoming increasingly important in the mental health care sector, one of its weaknesses is that ROM is not always sufficiently service user-oriented. First, clinicians tend to concentrate on those ROM results that provide information about clinical symptoms and functioning, whereas it has been suggested that a service user-oriented approach needs to focus on personal recovery. Second, service users have limited access to ROM results and they are often not equipped to interpret them. These problems need to be addressed, as access to resources and the opportunity to share decision making has been indicated as a prerequisite for service users to become a more equal partner in communication with their clinicians. Furthermore, shared decision making has been shown to improve the therapeutic alliance and to lead to better care. Our aim is to build a web-based support system which makes ROM results more accessible to service users and to provide them with more concrete and personalized information about their functioning (ie, symptoms, housing, social contacts) that they can use to discuss treatment options with their clinician. In this study, we will report on the usability of the web-based support system for service users with schizophrenia. First, we developed a prototype of a web-based support system in a multidisciplinary project team, including end-users. We then conducted a usability study of the support system consisting of (1) a heuristic evaluation, (2) a qualitative evaluation and (3) a quantitative evaluation. Fifteen service users with a schizophrenia diagnosis and four information and communication technology (ICT) experts participated in the study. The results show that people with a schizophrenia diagnosis were able to use the support system easily. Furthermore, the content of the advice generated by the support system was considered meaningful and supportive. This study shows that the support system prototype has valuable potential to improve the ROM practice and it is worthwhile to further develop it into a more mature system. Furthermore, the results add to prior research into web applications for people with psychotic disorders, in that it shows that this group of end users can work with web-based and computer-based systems, despite the cognitive problems they experience.

  20. Reduced-Order Modeling of 3D Rayleigh-Benard Turbulent Convection

    NASA Astrophysics Data System (ADS)

    Hassanzadeh, Pedram; Grover, Piyush; Nabi, Saleh

    2017-11-01

    Accurate Reduced-Order Models (ROMs) of turbulent geophysical flows have broad applications in science and engineering; for example, to study the climate system or to perform real-time flow control/optimization in energy systems. Here we focus on 3D Rayleigh-Benard turbulent convection at the Rayleigh number of 106 as a prototype for turbulent geophysical flows, which are dominantly buoyancy driven. The purpose of the study is to evaluate and improve the performance of different model reduction techniques using this setting. One-dimensional ROMs for horizontally averaged temperature are calculated using several methods. Specifically, the Linear Response Function (LRF) of the system is calculated from a large DNS dataset using Dynamic Mode Decomposition (DMD) and Fluctuation-Dissipation Theorem (FDT). The LRF is also calculated using the Green's function method of Hassanzadeh and Kuang (2016, J. Atmos. Sci.), which is based on using numerous forced DNS runs. The performance of these LRFs in estimating the system's response to weak external forcings or controlling the time-mean flow are compared and contrasted. The spectral properties of the LRFs and the scaling of the accuracy with the length of the dataset (for the data-driven methods) are also discussed.

  1. Low-order modelling of shallow water equations for sensitivity analysis using proper orthogonal decomposition

    NASA Astrophysics Data System (ADS)

    Zokagoa, Jean-Marie; Soulaïmani, Azzeddine

    2012-06-01

    This article presents a reduced-order model (ROM) of the shallow water equations (SWEs) for use in sensitivity analyses and Monte-Carlo type applications. Since, in the real world, some of the physical parameters and initial conditions embedded in free-surface flow problems are difficult to calibrate accurately in practice, the results from numerical hydraulic models are almost always corrupted with uncertainties. The main objective of this work is to derive a ROM that ensures appreciable accuracy and a considerable acceleration in the calculations so that it can be used as a surrogate model for stochastic and sensitivity analyses in real free-surface flow problems. The ROM is derived using the proper orthogonal decomposition (POD) method coupled with Galerkin projections of the SWEs, which are discretised through a finite-volume method. The main difficulty of deriving an efficient ROM is the treatment of the nonlinearities involved in SWEs. Suitable approximations that provide rapid online computations of the nonlinear terms are proposed. The proposed ROM is applied to the simulation of hypothetical flood flows in the Bordeaux breakwater, a portion of the 'Rivière des Prairies' located near Laval (a suburb of Montreal, Quebec). A series of sensitivity analyses are performed by varying the Manning roughness coefficient and the inflow discharge. The results are satisfactorily compared to those obtained by the full-order finite volume model.

  2. [Analysis of a three-dimensional finite element model of atlas and axis complex fracture].

    PubMed

    Tang, X M; Liu, C; Huang, K; Zhu, G T; Sun, H L; Dai, J; Tian, J W

    2018-05-22

    Objective: To explored the clinical application of the three-dimensional finite element model of atlantoaxial complex fracture. Methods: A three-dimensional finite element model of cervical spine (FEM/intact) was established by software of Abaqus6.12.On the basis of this model, a three-dimensional finite element model of four types of atlantoaxial complex fracture was established: C(1) fracture (Jefferson)+ C(2) fracture (type Ⅱfracture), Jefferson+ C(2) fracture(type Ⅲfracture), Jefferson+ C(2) fracture(Hangman), Jefferson+ stable C(2) fracture (FEM/fracture). The range of motion under flexion, extension, lateral bending and axial rotation were measured and compared with the model of cervical spine. Results: The three-dimensional finite element model of four types of atlantoaxial complex fracture had the same similarity and profile.The range of motion (ROM) of different segments had different changes.Compared with those in the normal model, the ROM of C(0/1) and C(1/2) in C(1) combined Ⅱ odontoid fracture model in flexion/extension, lateral bending and rotation increased by 57.45%, 29.34%, 48.09% and 95.49%, 88.52%, 36.71%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined Ⅲodontoid fracture model in flexion/extension, lateral bending and rotation increased by 47.01%, 27.30%, 45.31% and 90.38%, 27.30%, 30.0%.The ROM of C(0/1) and C(1/2) in C(1) combined Hangman fracture model in flexion/extension, lateral bending and rotation increased by 32.68%, 79.34%, 77.62% and 60.53%, 81.20%, 21.48%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined axis fracture model in flexion/extension, lateral bending and rotation increased by 15.00%, 29.30%, 8.47% and 37.87%, 75.57%, 8.30%, respectively. Conclusions: The three-dimensional finite element model can be used to simulate the biomechanics of atlantoaxial complex fracture.The ROM of atlantoaxial complex fracture is larger than nomal model, which indicates that surgical treatment should be performed.

  3. Physical-Biological-Optics Model Development and Simulation for the Pacific Ocean and Monterey Bay, California

    DTIC Science & Technology

    2012-09-30

    collaborate with Dr. Curt Mobley at Sequoia Scientific for the second scheme to implement the updated version of EcoLight into the ROMS-CoSiNE model...collaborating with Dr. Curtis Mobley of Sequoia Scientific on improving the link between the radiative transfer model (EcoLight) within the ROMS-CoSiNE

  4. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    PubMed

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  5. SCUTREA Conference Proceedings, 1970-1997. 25th Anniversary CD-ROM.

    ERIC Educational Resources Information Center

    Standing Conference on Univ. Teaching and Research in the Education of Adults.

    This CD-ROM contains 693 papers on university teaching and research in the education of adults that were presented during the 27-year period from 1970 through 1997. The CD-ROM is designed to be used with the Macintosh, Windows 95, and Windows 3.1 operating systems and Adobe Acrobat Portable Document Format (version 3), which is included along with…

  6. The planetary data system educational CD-ROM

    NASA Technical Reports Server (NTRS)

    Guinness, E. A.; Arvidson, R. E.; Martin, M.; Dueck, S.

    1993-01-01

    The Planetary Data System (PDS) is producing a special educational CD-ROM that contains samples of PDS datasets and is expected to be released in 1993. The CD-ROM will provide university-level instructors with PDS-compatible materials and information that can be used to construct student problem sets using real datasets. The main purposes of the CD-ROM are to facilitate wide use of planetary data and to introduce a large community to the PDS. To meet these objectives the Educational CD-ROM will also contain software to manipulate the data, background discussions about scientific questions that can be addressed with the data, and a suite of exercises that illustrate analysis techniques. Students will also be introduced to the SPICE concept, which is a new way of maintaining geometry and instrument information. The exercises will be presented at the freshman through graduate student levels. With simplification, some of the material should also be of use at the high school level.

  7. Applicability of aquifer impact models to support decisions at CO 2 sequestration sites

    DOE PAGES

    Keating, Elizabeth; Bacon, Diana; Carroll, Susan; ...

    2016-07-25

    The National Risk Assessment Partnership has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. This capability includes polynomial or look-up table based reduced-order models (ROMs) that predict the impact of CO 2 and brine leaks on overlying aquifers. The development of these computationally-efficient models and the underlying reactive transport simulations they emulate has been documented elsewhere (Carroll et al., 2014a; Carroll et al., 2014b; Dai et al., 2014 ; Keating et al., 2016). Here in this paper, we seek to demonstrate applicability of ROM-based analysis by considering what types of decisions and aquifermore » types would benefit from the ROM analysis. We present four hypothetical examples where applying ROMs, in ensemble mode, could support decisions during a geologic CO 2 sequestration project. These decisions pertain to site selection, site characterization, monitoring network evaluation, and health impacts. In all cases, we consider potential brine/CO 2 leak rates at the base of the aquifer to be uncertain. We show that derived probabilities provide information relevant to the decision at hand. Although the ROMs were developed using site-specific data from two aquifers (High Plains and Edwards), the models accept aquifer characteristics as variable inputs and so they may have more broad applicability. We conclude that pH and TDS predictions are the most transferable to other aquifers based on the analysis of the nine water quality metrics (pH, TDS, 4 trace metals, 3 organic compounds). Guidelines are presented for determining the aquifer types for which the ROMs should be applicable.« less

  8. Multi-Level Reduced Order Modeling Equipped with Probabilistic Error Bounds

    NASA Astrophysics Data System (ADS)

    Abdo, Mohammad Gamal Mohammad Mostafa

    This thesis develops robust reduced order modeling (ROM) techniques to achieve the needed efficiency to render feasible the use of high fidelity tools for routine engineering analyses. Markedly different from the state-of-the-art ROM techniques, our work focuses only on techniques which can quantify the credibility of the reduction which can be measured with the reduction errors upper-bounded for the envisaged range of ROM model application. Our objective is two-fold. First, further developments of ROM techniques are proposed when conventional ROM techniques are too taxing to be computationally practical. This is achieved via a multi-level ROM methodology designed to take advantage of the multi-scale modeling strategy typically employed for computationally taxing models such as those associated with the modeling of nuclear reactor behavior. Second, the discrepancies between the original model and ROM model predictions over the full range of model application conditions are upper-bounded in a probabilistic sense with high probability. ROM techniques may be classified into two broad categories: surrogate construction techniques and dimensionality reduction techniques, with the latter being the primary focus of this work. We focus on dimensionality reduction, because it offers a rigorous approach by which reduction errors can be quantified via upper-bounds that are met in a probabilistic sense. Surrogate techniques typically rely on fitting a parametric model form to the original model at a number of training points, with the residual of the fit taken as a measure of the prediction accuracy of the surrogate. This approach, however, does not generally guarantee that the surrogate model predictions at points not included in the training process will be bound by the error estimated from the fitting residual. Dimensionality reduction techniques however employ a different philosophy to render the reduction, wherein randomized snapshots of the model variables, such as the model parameters, responses, or state variables, are projected onto lower dimensional subspaces, referred to as the "active subspaces", which are selected to capture a user-defined portion of the snapshots variations. Once determined, the ROM model application involves constraining the variables to the active subspaces. In doing so, the contribution from the variables discarded components can be estimated using a fundamental theorem from random matrix theory which has its roots in Dixon's theory, developed in 1983. This theory was initially presented for linear matrix operators. The thesis extends this theorem's results to allow reduction of general smooth nonlinear operators. The result is an approach by which the adequacy of a given active subspace determined using a given set of snapshots, generated either using the full high fidelity model, or other models with lower fidelity, can be assessed, which provides insight to the analyst on the type of snapshots required to reach a reduction that can satisfy user-defined preset tolerance limits on the reduction errors. Reactor physics calculations are employed as a test bed for the proposed developments. The focus will be on reducing the effective dimensionality of the various data streams such as the cross-section data and the neutron flux. The developed methods will be applied to representative assembly level calculations, where the size of the cross-section and flux spaces are typically large, as required by downstream core calculations, in order to capture the broad range of conditions expected during reactor operation. (Abstract shortened by ProQuest.).

  9. Remote Access to CD-ROM for the Distant Learner.

    ERIC Educational Resources Information Center

    Cutright, Patricia; Girrard, Kenneth M.

    1991-01-01

    A dial-access, multiuser, multiaccess CD-ROM search system with end-user capability was developed to provide Eastern Oregon State College distance education students with access to the information required by their studies. Based on UNIX, the system provides students with access to 12 databases, an e-mail system for messaging, interlibrary loan…

  10. The CD-ROM Services of SilverPlatter Information, Inc.

    ERIC Educational Resources Information Center

    Allen, Robert J.

    1985-01-01

    The SilverPlatter system is a complete, stand-alone system, consisting of an IBM (or compatible) personal computer, compact disc with read-only memory (CD-ROM) drive, software, and one or more databases. Large databases (e.g., ERIC, PsycLIT) will soon be available on the system for "local" installation in schools, libraries, and…

  11. Comparing a quasi-3D to a full 3D nearshore circulation model: SHORECIRC and ROMS

    USGS Publications Warehouse

    Haas, Kevin A.; Warner, John C.

    2009-01-01

    Predictions of nearshore and surf zone processes are important for determining coastal circulation, impacts of storms, navigation, and recreational safety. Numerical modeling of these systems facilitates advancements in our understanding of coastal changes and can provide predictive capabilities for resource managers. There exists many nearshore coastal circulation models, however they are mostly limited or typically only applied as depth integrated models. SHORECIRC is an established surf zone circulation model that is quasi-3D to allow the effect of the variability in the vertical structure of the currents while maintaining the computational advantage of a 2DH model. Here we compare SHORECIRC to ROMS, a fully 3D ocean circulation model which now includes a three dimensional formulation for the wave-driven flows. We compare the models with three different test applications for: (i) spectral waves approaching a plane beach with an oblique angle of incidence; (ii) monochromatic waves driving longshore currents in a laboratory basin; and (iii) monochromatic waves on a barred beach with rip channels in a laboratory basin. Results identify that the models are very similar for the depth integrated flows and qualitatively consistent for the vertically varying components. The differences are primarily the result of the vertically varying radiation stress utilized by ROMS and the utilization of long wave theory for the radiation stress formulation in vertical varying momentum balance by SHORECIRC. The quasi-3D model is faster, however the applicability of the fully 3D model allows it to extend over a broader range of processes, temporal, and spatial scales.

  12. Comparing a quasi-3D to a full 3D nearshore circulation model: SHORECIRC and ROMS

    USGS Publications Warehouse

    Haas, K.A.; Warner, J.C.

    2009-01-01

    Predictions of nearshore and surf zone processes are important for determining coastal circulation, impacts of storms, navigation, and recreational safety. Numerical modeling of these systems facilitates advancements in our understanding of coastal changes and can provide predictive capabilities for resource managers. There exists many nearshore coastal circulation models, however they are mostly limited or typically only applied as depth integrated models. SHORECIRC is an established surf zone circulation model that is quasi-3D to allow the effect of the variability in the vertical structure of the currents while maintaining the computational advantage of a 2DH model. Here we compare SHORECIRC to ROMS, a fully 3D ocean circulation model which now includes a three dimensional formulation for the wave-driven flows. We compare the models with three different test applications for: (i) spectral waves approaching a plane beach with an oblique angle of incidence; (ii) monochromatic waves driving longshore currents in a laboratory basin; and (iii) monochromatic waves on a barred beach with rip channels in a laboratory basin. Results identify that the models are very similar for the depth integrated flows and qualitatively consistent for the vertically varying components. The differences are primarily the result of the vertically varying radiation stress utilized by ROMS and the utilization of long wave theory for the radiation stress formulation in vertical varying momentum balance by SHORECIRC. The quasi-3D model is faster, however the applicability of the fully 3D model allows it to extend over a broader range of processes, temporal, and spatial scales. ?? 2008 Elsevier Ltd.

  13. Use of CD-ROM MEDLINE by medical students of the College of Medicine, University of Lagos, Nigeria.

    PubMed

    Ogunyade, Taiwo O; Oyibo, Wellington A

    2003-01-01

    Use of information technology in information acquisition, especially MEDLINE on CD-ROM and online, has been evaluated in several localities and regions, especially in the advanced countries. Use of MEDLINE on CD-ROM is still very poor among the medical students of the University of Lagos, Lagos, Nigeria, due to lack of awareness, insufficient personal computers, nonperiodic training, and the high cost of using the facility. Due to financial constraints, MEDLINE online and sufficiently-networked computer systems are not available. To report on the situation in Nigeria, a developing country, so as to compare the current awareness of searching MEDLINE on CD-ROM among the medical students at the University of Lagos with the awareness of their overseas' counterparts. This is the first step toward setting up an online PubMed search as well as expanding the computer systems and network. Essentially based on cross-sectional proportional sampling using structured questionnaires, in-depth interviews, and focus-group discussions among the medical students and library staff. The study involved the medical students in their second year to sixth (final) year of study. Of the 250 students interviewed, 130 (52%) were aware of MEDLINE on CD-ROM searches as a means of information retrieval. Only 60 (24%) had used MEDLINE on CD-ROM-2% had used MEDLINE on CD-ROM more than 9 times; 4%, 7 to 9 times; 8%, 4 to 6 times; and 10%, 1 to 3 times. Of the students who used MEDLINE on CD-ROM search, 22% used it in preparing for examinations, 24% in research, 6% in patient care, and 26% in preparation of assignments and clinical cases. Lack of awareness (52%) and cost of undertaking MEDLINE on CD-ROM search (46%) were identified as important factors that discouraged the use of MEDLINE on CD-ROM. Though the above factors were recognized as important, it was concluded that the reasons for the poor use of MEDLINE on CD-ROM are multifactorial. Poor use of MEDLINE on CD-ROM could be attributed to these critical underlying factors: nonavailability of networked personal computers, which should be connected to a central server; lack of mandatory assignments to the medical students that would specifically require use of MEDLINE on CD-ROM; financial constraints on the university management; and infrequent periodic orientation on use of MEDLINE on CD-ROM. It was therefore suggested that the number of personal computers should be increased and that the library staff should periodically train the preclinical and clinical medical students in searching MEDLINE on CD-ROM. These steps would enable the medical students to benefit from online PubMed searching when it becomes fully operational in the future.

  14. Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.

    PubMed

    Kim, Jun-Young; Cheon, Sang-Ho; Kyung, Hee-Soo

    2012-12-01

    We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The mean follow-up period was 65 months (range, 60-69 months). The evaluation system of the American knee society was used for clinical and radiological assessment. Also, the maximal knee flexion angle was assessed. The mean maximum flexion angle in the study group (135°) was greater than that in the control group (125°) at the early post-operation & final follow-up period (p=0.033). The range of motion (ROM) in the study group was recovered earlier at the postoperative 6 months, and ROM gain was improved to a greater extent at the final follow-up period (p=0.039). The knee score and function score and radiographic evaluation were no difference between the two groups (p>0.05) at the final follow-up. The two cases of radiolucency in posterior condyle and medial tibial plateau and one case of patellar elongation were seen in the study group. The PFC Sigma RP-F mobile system appears to facilitate greater maximum flexion angle and ROM gain with two cases of radiolucent line.

  15. Applicability of aquifer impact models to support decisions at CO2 sequestration sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keating, Elizabeth; Bacon, Diana; Carroll, Susan

    2016-09-01

    The National Risk Assessment Partnership has developed a suite of tools to assess and manage risk at CO2 sequestration sites (www.netldoe.gov/nrap). This capability includes polynomial or look-up table based reduced-order models (ROMs) that predict the impact of CO2 and brine leaks on overlying aquifers. The development of these computationally-efficient models and the underlying reactive transport simulations they emulate has been documented elsewhere (Carroll et al., 2014, Dai et al., 2014, Keating et al., 2015). The ROMs reproduce the ensemble behavior of large numbers of simulations and are well-suited to applications that consider a large number of scenarios to understand parametermore » sensitivity and uncertainty on the risk of CO2 leakage to groundwater quality. In this paper, we seek to demonstrate applicability of ROM-based ensemble analysis by considering what types of decisions and aquifer types would benefit from the ROM analysis. We present four hypothetical four examples where applying ROMs, in ensemble mode, could support decisions in the early stages in a geologic CO2 sequestration project. These decisions pertain to site selection, site characterization, monitoring network evaluation, and health impacts. In all cases, we consider potential brine/CO2 leak rates at the base of the aquifer to be uncertain. We show that derived probabilities provide information relevant to the decision at hand. Although the ROMs were developed using site-specific data from two aquifers (High Plains and Edwards), the models accept aquifer characteristics as variable inputs and so they may have more broad applicability. We conclude that pH and TDS predictions are the most transferable to other aquifers based on the analysis of the nine water quality metrics (pH, TDS, 4 trace metals, 3 organic compounds). Guidelines are presented for determining the aquifer types for which the ROMs should be applicable.« less

  16. Preliminary validation of the Review of Musculoskeletal System (ROMS) questionnaire.

    PubMed

    Bershadsky, Boris; Kane, Robert L; Wuerz, Thomas; Jones, Morgan; Brighton, Brian; Stitzlein, Russell; Parker, Richard; Iannotti, Joseph P

    2015-04-01

    Measurement of clinical outcomes is necessary to define best practice. It requires a validated tool that can be easily applied as part of clinical practice. We present the preliminary validation of a brief self-reported Review of Musculoskeletal System (ROMS) questionnaire that captures functional limitations due to musculoskeletal problems and other medical and emotional conditions. Data were derived from a clinical outcomes database (Orthopaedic Minimal Data Set [OrthoMiDaS]) that combines patient-reported data collected as part of routine care and secondary data extracted from electronic medical records. The study utilized 82,873 encounters collected from 24,116 consecutive patients with problems in the upper and lower extremities. In addition to the ROMS, the study used version 2 of the Short Form-12 (SF-12v2), the Penn Shoulder Score (PSS), the Hip disability and Osteoarthritis Outcome Score (HOOS), and the Knee injury and Osteoarthritis Outcome Score (KOOS) questionnaires. Fifteen cross-sectional samples were used to evaluate the floor and ceiling effects as well as the construct and content validity. Five longitudinal cohorts were used to measure test-retest reliability and responsiveness. Standard statistical tests were applied. The floor and ceiling effects of the ROMS questionnaire in patients with shoulder, hip, and knee problems ranged from 1.3% to 8.5%. Construct-validity tests confirmed convergent and divergent validity of the ROMS. The tests also justified its additional value when the ROMS was used with joint-specific tools. When measuring test-retest reliability of the ROMS scales, intraclass correlation ranged from 0.80 to 0.90 at approximately one week and from 0.71 to 0.87 at approximately four weeks. Responsiveness of the ROMS was greater than that of the SF-12 and less than that of the joint-specific questionnaires. The ROMS is compatible with routine clinical process and has good psychometric properties in patients with shoulder, hip, and knee disorders. It can be used as a primary outcome tool for large observational studies and can supplement more specific tools in controlled studies. The ROMS was developed as a tool to measure and monitor the clinical status of the musculoskeletal system in a population of patients during and after treatment as well as over time. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  17. Restoration of Full Shoulder Range of Motion After Application of the Fascial Distortion Model.

    PubMed

    Boucher, Joshua D; Figueroa, Jose

    2018-05-01

    Decreased active and passive range of motion (ROM) accompanied by pain in the shoulder is a common presentation for patients with frozen shoulder, and it can be difficult to restore normal function. Through the fascial distortion model, physicians can apply a manual technique to rapidly and effectively increase ROM and decrease pain. A 28-year-old man presented 18 months after sustaining a shoulder hyperextension injury. On active and passive ROM examination, he had approximately 90° of shoulder abduction and moderately reduced internal rotation associated with 8/10 pain. After 2 applications of the fascial distortion model, his shoulder restored to full abduction and internal rotation with no pain.

  18. Is there a role for rifampicin, ofloxacin and minocycline (ROM) therapy in the treatment of leprosy? Systematic review and meta-analysis.

    PubMed

    Setia, Maninder S; Shinde, Santosh S; Jerajani, Hemangi R; Boivin, Jean-François

    2011-12-01

    A combination of rifampicin, ofloxacin and minocycline (ROM) is one of the newer recommendations for treatment of leprosy. We performed a systematic review and a meta-analysis of studies that had evaluated the efficacy of ROM therapy in treatment of paucibacillary and multibacillary leprosy patients. Studies were identified by searching the PubMed, Embase, LILACS and Cochrane databases. Data were abstracted from all relevant studies, and fixed effects models were used to calculate the summary estimate of effect in paucibacillary and multibacillary leprosy patients. Six studies comparing ROM therapy to multidrug therapy and eight studies that evaluated the effect of ROM therapy alone (no comparison group) were included in the review and meta-analysis. The combined estimate for single dose ROM vs. multidrug therapy in paucibacillary leprosy patients suggested that ROM was less effective than multidrug therapy in these patients [relative risk: 0.91, 95% confidence intervals (CI): 0.86-0.97]. However, the combined estimate for multiple doses of ROM vs. multidrug therapy in multibacillary leprosy patients suggested that ROM was as effective as multidrug therapy in reducing bacillary indices in these patients (proportion change: -4%, 95% CI -31% to 23%). No major side effects were reported in either the ROM or the multidrug treatment groups. Single-dose ROM therapy was less effective than multidrug therapy in paucibacillary patients. However, there are insufficient data to come to a valid conclusion on the efficacy of multidose ROM therapy in multibacillary leprosy, and additional studies with ROM therapy in multibacillary leprosy are needed. Furthermore, multiple doses may be considered as another alternative even for paucibacillary patients, and randomised controlled trials of this therapy may be useful to understand its contribution in the treatment and control of leprosy. © 2011 Blackwell Publishing Ltd.

  19. A reduced-order model for compressible flows with buffeting condition using higher order dynamic mode decomposition with a mode selection criterion

    NASA Astrophysics Data System (ADS)

    Kou, Jiaqing; Le Clainche, Soledad; Zhang, Weiwei

    2018-01-01

    This study proposes an improvement in the performance of reduced-order models (ROMs) based on dynamic mode decomposition to model the flow dynamics of the attractor from a transient solution. By combining higher order dynamic mode decomposition (HODMD) with an efficient mode selection criterion, the HODMD with criterion (HODMDc) ROM is able to identify dominant flow patterns with high accuracy. This helps us to develop a more parsimonious ROM structure, allowing better predictions of the attractor dynamics. The method is tested in the solution of a NACA0012 airfoil buffeting in a transonic flow, and its good performance in both the reconstruction of the original solution and the prediction of the permanent dynamics is shown. In addition, the robustness of the method has been successfully tested using different types of parameters, indicating that the proposed ROM approach is a tool promising for using in both numerical simulations and experimental data.

  20. Reference System of DNA and Protein Sequences on CD-ROM

    NASA Astrophysics Data System (ADS)

    Nasu, Hisanori; Ito, Toshiaki

    DNASIS-DBREF31 is a database for DNA and Protein sequences in the form of optical Compact Disk (CD) ROM, developed and commercialized by Hitachi Software Engineering Co., Ltd. Both nucleic acid base sequences and protein amino acid sequences can be retrieved from a single CD-ROM. Existing database is offered in the form of on-line service, floppy disks, or magnetic tape, all of which have some problems or other, such as usability or storage capacity. DNASIS-DBREF31 newly adopt a CD-ROM as a database device to realize a mass storage and personal use of the database.

  1. Thin Client Architecture for Networking CD-ROMs in a Medium-Sized Public Library System.

    ERIC Educational Resources Information Center

    Turner, Anna

    1997-01-01

    Describes how the Tulsa City-County Library System built a 22-branch CD-ROM-based network with the emerging thin-client/server technology, and succeeded in providing patrons with the most current research tools and information resources available. Discusses costs; networking options; the Citrix WinFrame system used; equipment and connectivity.…

  2. FAPA: Faculty Appointment Policy Archive, 1998. [CD-ROM.

    ERIC Educational Resources Information Center

    Trower, C. Ann

    This CD-ROM presents 220 documents collected in Harvard University's Faculty Appointment Policy Archive (FAPA), the ZyFIND search and retrieval system, and instructions for their use. The FAPA system and ZyFIND allow browsing through documents, inserting bookmarks in documents, attaching notes to documents without modifying them, and selecting…

  3. CD-ROM Networking: Navigating through VINES and NetWare and the New Software Technologies.

    ERIC Educational Resources Information Center

    Lieberman, Paula

    1995-01-01

    Provides an overview of developments in CD-ROM networking technology and describes products offered by Axis, Banyan (VINES--network operating environment), CD Connection, Celerity, Data/Ware, Document Imaging Systems Corporation (DISC), Imagery, Jodian, Meridian, Micro Design International, Microsoft, Microtest, Novell, OnLine Computer Systems,…

  4. Energy-Smart Choices for Schools. An HVAC Comparison Tool. [CD-ROM].

    ERIC Educational Resources Information Center

    Geothermal Heat Pump Consortium, Inc., Washington, DC.

    A CD ROM program provides comparison construction cost capabilities for heating, ventilation, and air conditioning (HVAC) systems in educational facilities. The program combines multiple types of systems with square footage data on low and high construction cost and school size to automatically calculate HVAC comparative construction costs. (GR)

  5. IDC Reengineering Phase 2 & 3 Rough Order of Magnitude (ROM) Cost Estimate Summary (Leveraged NDC Case).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, James M.; Prescott, Ryan; Dawson, Jericah M.

    2014-11-01

    Sandia National Laboratories has prepared a ROM cost estimate for budgetary planning for the IDC Reengineering Phase 2 & 3 effort, based on leveraging a fully funded, Sandia executed NDC Modernization project. This report provides the ROM cost estimate and describes the methodology, assumptions, and cost model details used to create the ROM cost estimate. ROM Cost Estimate Disclaimer Contained herein is a Rough Order of Magnitude (ROM) cost estimate that has been provided to enable initial planning for this proposed project. This ROM cost estimate is submitted to facilitate informal discussions in relation to this project and is NOTmore » intended to commit Sandia National Laboratories (Sandia) or its resources. Furthermore, as a Federally Funded Research and Development Center (FFRDC), Sandia must be compliant with the Anti-Deficiency Act and operate on a full-cost recovery basis. Therefore, while Sandia, in conjunction with the Sponsor, will use best judgment to execute work and to address the highest risks and most important issues in order to effectively manage within cost constraints, this ROM estimate and any subsequent approved cost estimates are on a 'full-cost recovery' basis. Thus, work can neither commence nor continue unless adequate funding has been accepted and certified by DOE.« less

  6. Submesoscale Flows and Mixing in the Ocean Surface Layer Using the Regional Oceanic Modeling System (ROMS)

    DTIC Science & Technology

    2013-09-30

    chemical cycles, water quality, blooms , micro-nutrients, larval dispersal, biome transitions, and coupling to higher tropic levels. We collaborate with...Kurian, 2012: Heat balance and eddies in the Peru- Chile Current System. Climate Dynamics 39, 509-529, doi:10.1007/s00382-011-1170-6. Colas, F., X

  7. A wetting and drying scheme for ROMS

    USGS Publications Warehouse

    Warner, John C.; Defne, Zafer; Haas, Kevin; Arango, Hernan G.

    2013-01-01

    The processes of wetting and drying have many important physical and biological impacts on shallow water systems. Inundation and dewatering effects on coastal mud flats and beaches occur on various time scales ranging from storm surge, periodic rise and fall of the tide, to infragravity wave motions. To correctly simulate these physical processes with a numerical model requires the capability of the computational cells to become inundated and dewatered. In this paper, we describe a method for wetting and drying based on an approach consistent with a cell-face blocking algorithm. The method allows water to always flow into any cell, but prevents outflow from a cell when the total depth in that cell is less than a user defined critical value. We describe the method, the implementation into the three-dimensional Regional Oceanographic Modeling System (ROMS), and exhibit the new capability under three scenarios: an analytical expression for shallow water flows, a dam break test case, and a realistic application to part of a wetland area along the Georgia Coast, USA.

  8. A Real-Time California Coastal Ocean Nowcast/Forecast System: Skill Assessment, User Products, and Transition from Research to Operations

    NASA Astrophysics Data System (ADS)

    Farrara, J. D.; Chao, Y.; Chai, F.; Zhang, H.

    2016-02-01

    The real-time California coastal ocean nowcast/forecast system is described. The model is based on the Regional Ocean Modeling System (ROMS) and covers the entire California coastal ocean with a horizontal resolution of 3 km and 40 vertical layers. The atmospheric forcing is derived from the operational regional atmospheric model forecasts. The lateral boundary conditions are provided by the operational ocean model forecasts. A multi-scale 3-dimensional variational (3DVAR) data assimilation scheme is used to assimilate both in situ (e.g., vertical profiles of temperature and salinity) and remotely sensed data from both satellite (e.g., sea surface temperature and sea surface height) and land-based platforms (e.g., surface current). The performance of our nowcast/forecast system is evaluated in real-time by a number of metrics that are published as soon as they become available. User tools and products have been developed for both general users and super-users (e.g., NOAA Office of Response and Restoration and USCG). Recent results comparing the 3DVAR with the ensemble Kalman Filter (EnKF) using Data Assimilation Research Testbed (DART) will be presented. Preliminary results coupling the ROMS circulation model with a biogeochemistry/ecosystem model (i.e., CoSiNE) will also discussed. Cloud computing services (e.g., Microsoft, Google) are now being tested to increase the reliability and timeliness in order to be accepted as a truly operational system in the near future.

  9. Advanced Fluid Reduced Order Models for Compressible Flow.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tezaur, Irina Kalashnikova; Fike, Jeffrey A.; Carlberg, Kevin Thomas

    This report summarizes fiscal year (FY) 2017 progress towards developing and implementing within the SPARC in-house finite volume flow solver advanced fluid reduced order models (ROMs) for compressible captive-carriage flow problems of interest to Sandia National Laboratories for the design and qualification of nuclear weapons components. The proposed projection-based model order reduction (MOR) approach, known as the Proper Orthogonal Decomposition (POD)/Least- Squares Petrov-Galerkin (LSPG) method, can substantially reduce the CPU-time requirement for these simulations, thereby enabling advanced analyses such as uncertainty quantification and de- sign optimization. Following a description of the project objectives and FY17 targets, we overview briefly themore » POD/LSPG approach to model reduction implemented within SPARC . We then study the viability of these ROMs for long-time predictive simulations in the context of a two-dimensional viscous laminar cavity problem, and describe some FY17 enhancements to the proposed model reduction methodology that led to ROMs with improved predictive capabilities. Also described in this report are some FY17 efforts pursued in parallel to the primary objective of determining whether the ROMs in SPARC are viable for the targeted application. These include the implemen- tation and verification of some higher-order finite volume discretization methods within SPARC (towards using the code to study the viability of ROMs on three-dimensional cavity problems) and a novel structure-preserving constrained POD/LSPG formulation that can improve the accuracy of projection-based reduced order models. We conclude the report by summarizing the key takeaways from our FY17 findings, and providing some perspectives for future work.« less

  10. CD-ROM And Knowledge Integration

    NASA Astrophysics Data System (ADS)

    Rann, Leonard S.

    1988-06-01

    As the title of this paper suggests, it is about CD-ROM technology and the structuring of massive databases. Even more, it is about the impact CD-ROM has had on the publication of massive amounts of information, and the unique qualities of the medium that allows for the most sophisticated computer retrieval techniques that have ever been used. I am not drawing on experience as a pedant in the educational field, but rather as a software and database designer who has worked with CD-ROM since its inception. I will be giving examples from my company's current applications, as well as discussing some of the challenges that face information publishers in the future. In particular I have a belief about what the most valuable outlet can be created using CD-ROM will be: The CD-ROM is particularly suited for the mass delivery of information systems and databases that either require or utilize a large amount of computational preprocessing to allow a real-time or interactive response to be achieved. Until the advent of CD-ROM technology this level of sophistication in publication was virtually impossible. I will further explain this later in this paper. First, I will discuss the salient features of CD-ROM that make it unique in the world of data storage for electronic publishing.

  11. Development and evaluation of an interactive CD-ROM for children with leukemia and their families.

    PubMed

    Dragone, Mary Alice; Bush, Patricia J; Jones, Judith K; Bearison, David J; Kamani, Sharmila

    2002-04-01

    To meet the need for an interactive software product to educate children with leukemia, ages 4-11 years, and their families about the disease and its treatment, we developed and evaluated an interactive, comprehensive, multimedia CD-ROM product, Kidz with Leukemia: A Space Adventure. The prototype was tested using a randomized controlled experimental design. Children with leukemia and their parents were randomized to receive either the newly developed CD-ROM or the book You and Leukemia by Lynn Baker. Health care providers (HCPs) and other content/technical experts evaluated only the CD-ROM. Data were collected on children's health locus of control, their understanding of leukemia, and the satisfaction of participants with their assigned intervention. Children in the CD-ROM group, compared with those in the book group, showed increased feelings of control over their health. Although there was a high level of satisfaction with the CD-ROM among all users, younger children and their parents were most satisfied. In conclusion, the CD-ROM, Kidz with Leukemia: A Space Adventure, was found to be a useful, engaging, and empowering tool for children with leukemia and can serve as a model for developing future health-related educational materials.

  12. Characterizing the recovery trajectories of knee range of motion for one year after total knee replacement.

    PubMed

    Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali

    2018-06-13

    Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.

  13. In vitro biomechanical comparison after fixed- and mobile-core artificial cervical disc replacement versus fusion

    PubMed Central

    Lou, Jigang; Li, Yuanchao; Wang, Beiyu; Meng, Yang; Wu, Tingkui; Liu, Hao

    2017-01-01

    Abstract In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core prostheses. Six human cadaveric C2–C7 specimens were biomechanically tested sequentially in 4 different spinal models: intact specimens, simulated fusion, CDR with a fixed-core prosthesis (Discover, DePuy), and CDR with a mobile-core prosthesis (Pretic-I, Trauson). Moments up to 2 Nm with a 75 N follower load were applied in flexion–extension, left and right lateral bending, and left and right axial rotation. The total range of motion (ROM), segmental ROM, and adjacent intradiscal pressure (IDP) were calculated and analyzed in 4 different spinal models, as well as the differences between 2 disc prostheses. Compared with the intact specimens, the total ROM, segmental ROM, and IDP at the adjacent segments showed no significant difference after arthroplasty. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment (C5/6) and total ROM than CDR with a fixed-core prosthesis (P > .05). Besides, the difference in IDP at C4/5 after CDR with 2 prostheses was without statistical significance in all the directions of motion. However, the IDP at C6/7 after CDR with a mobile-core prosthesis was lower than CDR with a fixed-core prosthesis in flexion, extension, and lateral bending, with significant difference (P < .05), but not under axial rotation. CDR with a novel prosthesis was effective to maintain the ROM at the target segment and did not affect the ROM and IDP at the adjacent segments. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment and total ROM, but lower IDP at the inferior adjacent segment than CDR with a fixed-core prosthesis. PMID:29019902

  14. Reactor Operations Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, M.M.

    1989-01-01

    The Reactor Operations Monitoring System (ROMS) is a VME based, parallel processor data acquisition and safety action system designed by the Equipment Engineering Section and Reactor Engineering Department of the Savannah River Site. The ROMS will be analyzing over 8 million signal samples per minute. Sixty-eight microprocessors are used in the ROMS in order to achieve a real-time data analysis. The ROMS is composed of multiple computer subsystems. Four redundant computer subsystems monitor 600 temperatures with 2400 thermocouples. Two computer subsystems share the monitoring of 600 reactor coolant flows. Additional computer subsystems are dedicated to monitoring 400 signals from assortedmore » process sensors. Data from these computer subsystems are transferred to two redundant process display computer subsystems which present process information to reactor operators and to reactor control computers. The ROMS is also designed to carry out safety functions based on its analysis of process data. The safety functions include initiating a reactor scram (shutdown), the injection of neutron poison, and the loadshed of selected equipment. A complete development Reactor Operations Monitoring System has been built. It is located in the Program Development Center at the Savannah River Site and is currently being used by the Reactor Engineering Department in software development. The Equipment Engineering Section is designing and fabricating the process interface hardware. Upon proof of hardware and design concept, orders will be placed for the final five systems located in the three reactor areas, the reactor training simulator, and the hardware maintenance center.« less

  15. A reduced-order modeling approach to represent subgrid-scale hydrological dynamics for land-surface simulations: application in a polygonal tundra landscape

    DOE PAGES

    Pau, G. S. H.; Bisht, G.; Riley, W. J.

    2014-09-17

    Existing land surface models (LSMs) describe physical and biological processes that occur over a wide range of spatial and temporal scales. For example, biogeochemical and hydrological processes responsible for carbon (CO 2, CH 4) exchanges with the atmosphere range from the molecular scale (pore-scale O 2 consumption) to tens of kilometers (vegetation distribution, river networks). Additionally, many processes within LSMs are nonlinearly coupled (e.g., methane production and soil moisture dynamics), and therefore simple linear upscaling techniques can result in large prediction error. In this paper we applied a reduced-order modeling (ROM) technique known as "proper orthogonal decomposition mapping method" thatmore » reconstructs temporally resolved fine-resolution solutions based on coarse-resolution solutions. We developed four different methods and applied them to four study sites in a polygonal tundra landscape near Barrow, Alaska. Coupled surface–subsurface isothermal simulations were performed for summer months (June–September) at fine (0.25 m) and coarse (8 m) horizontal resolutions. We used simulation results from three summer seasons (1998–2000) to build ROMs of the 4-D soil moisture field for the study sites individually (single-site) and aggregated (multi-site). The results indicate that the ROM produced a significant computational speedup (> 10 3) with very small relative approximation error (< 0.1%) for 2 validation years not used in training the ROM. We also demonstrate that our approach: (1) efficiently corrects for coarse-resolution model bias and (2) can be used for polygonal tundra sites not included in the training data set with relatively good accuracy (< 1.7% relative error), thereby allowing for the possibility of applying these ROMs across a much larger landscape. By coupling the ROMs constructed at different scales together hierarchically, this method has the potential to efficiently increase the resolution of land models for coupled climate simulations to spatial scales consistent with mechanistic physical process representation.« less

  16. The effect of the remplissage procedure on shoulder range of motion: a cadaveric study.

    PubMed

    Omi, Rei; Hooke, Alexander W; Zhao, Kristin D; Matsuhashi, Tomoya; Goto, Akira; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Itoi, Eiji; An, Kai-Nan

    2014-02-01

    The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small- and large-sized Hill-Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would-be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Repeatability of stance phase kinematics from a multi-segment foot model in people aged 50 years and older.

    PubMed

    Arnold, John B; Mackintosh, Shylie; Jones, Sara; Thewlis, Dominic

    2013-06-01

    Confidence in 3D multi-segment foot models has been limited by a lack of repeatability data, particularly in older populations that may display unique functional foot characteristics. This study aimed to determine the intra and inter-observer repeatability of stance phase kinematic data from a multi-segment foot model described by Leardini et al. [2] in people aged 50 years or older. Twenty healthy adults participated (mean age 65.4 years SD 8.4). A repeated measures study design was used with data collected from four testing sessions on two days from two observers. Intra (within-day and between-day) and inter-observer coefficient of multiple correlations revealed moderate to excellent similarity of stance phase joint range of motion (0.621-0.975). Relative to the joint range of motion (ROM), mean differences (MD) between sessions were highest for the within-day comparison for all planar ROM at the metatarsus-midfoot articulation (sagittal plane ROM 5.2° vs. 3.9°, MD 3.1°; coronal plane ROM 3.9 vs. 3.1°, MD 2.3°; transverse plane ROM 6.8° vs. 5.16°, MD 3.5°). Consequently, data from the metatarsus-midfoot articulation in the Istituto Ortopedico Rizzoli (IOR) foot model in adults aged over 50 years needs to be considered with respect to the findings of this study. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  18. Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults.

    PubMed

    Tousignant, Michel; Smeesters, Cécil; Breton, Anne-Marie; Breton, Emilie; Corriveau, Hélène

    2006-04-01

    This study compared range of motion (ROM) measurements using a cervical range of motion device (CROM) and an optoelectronic system (OPTOTRAK). To examine the criterion validity of the CROM for the measurement of cervical ROM on healthy adults. Whereas measurements of cervical ROM are recognized as part of the assessment of patients with neck pain, few devices are available in clinical settings. Two papers published previously showed excellent criterion validity for measurements of cervical flexion/extension and lateral flexion using the CROM. Subjects performed neck rotation, flexion/extension, and lateral flexion while sitting on a wooden chair. The ROM values were measured by the CROM as well as the OPTOTRAK. The cervical rotational ROM values using the CROM demonstrated a good to excellent linear relationship with those using the OPTOTRAK: right rotation, r = 0.89 (95% confidence interval, 0.81-0.94), and left rotation, r = 0.94 (95% confidence interval, 0.90-0.97). Similar results were also obtained for flexion/extension and lateral flexion ROM values. The CROM showed excellent criterion validity for measurements of cervical rotation. We propose using ROM values measured by the CROM as outcome measures for patients with neck pain.

  19. CD volume design and verification

    NASA Technical Reports Server (NTRS)

    Li, Y. P.; Hughes, J. S.

    1993-01-01

    In this paper, we describe a prototype for CD-ROM volume design and verification. This prototype allows users to create their own model of CD volumes by modifying a prototypical model. Rule-based verification of the test volumes can then be performed later on against the volume definition. This working prototype has proven the concept of model-driven rule-based design and verification for large quantity of data. The model defined for the CD-ROM volumes becomes a data model as well as an executable specification.

  20. Data-Driven H∞ Control for Nonlinear Distributed Parameter Systems.

    PubMed

    Luo, Biao; Huang, Tingwen; Wu, Huai-Ning; Yang, Xiong

    2015-11-01

    The data-driven H∞ control problem of nonlinear distributed parameter systems is considered in this paper. An off-policy learning method is developed to learn the H∞ control policy from real system data rather than the mathematical model. First, Karhunen-Loève decomposition is used to compute the empirical eigenfunctions, which are then employed to derive a reduced-order model (ROM) of slow subsystem based on the singular perturbation theory. The H∞ control problem is reformulated based on the ROM, which can be transformed to solve the Hamilton-Jacobi-Isaacs (HJI) equation, theoretically. To learn the solution of the HJI equation from real system data, a data-driven off-policy learning approach is proposed based on the simultaneous policy update algorithm and its convergence is proved. For implementation purpose, a neural network (NN)- based action-critic structure is developed, where a critic NN and two action NNs are employed to approximate the value function, control, and disturbance policies, respectively. Subsequently, a least-square NN weight-tuning rule is derived with the method of weighted residuals. Finally, the developed data-driven off-policy learning approach is applied to a nonlinear diffusion-reaction process, and the obtained results demonstrate its effectiveness.

  1. IoGET: Internet of Geophysical and Environmental Things

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mudunuru, Maruti Kumar

    The objective of this project is to provide novel and fast reduced-order models for onboard computation at sensor nodes for real-time analysis. The approach will require that LANL perform high-fidelity numerical simulations, construct simple reduced-order models (ROMs) using machine learning and signal processing algorithms, and use real-time data analysis for ROMs and compressive sensing at sensor nodes.

  2. A Community Terrain-Following Ocean Modeling System (ROMS/TOMS)

    DTIC Science & Technology

    2013-09-30

    workshop at the Windsor Atlântica Hotel, Rio de Janeiro , Brazil, October 22-25, 2012. As in the past, several tutorials were offered on basic and...from the European Centre For Medium-Range Weather Forecasts (ECMWF) ERA-Interim, 3-hour dataset. River runoff is included along the Alabama

  3. Cryosphere-hydrosphere interactions: numerical modeling using the Regional Ocean Modeling System (ROMS) at different scales

    NASA Astrophysics Data System (ADS)

    Bergamasco, A.; Budgell, W. P.; Carniel, S.; Sclavo, M.

    2005-03-01

    Conveyor belt circulation controls global climate through heat and water fluxes with atmosphere and from tropical to polar regions and vice versa. This circulation, commonly referred to as thermohaline circulation (THC), seems to have millennium time scale and nowadays--a non-glacial period--appears to be as rather stable. However, concern is raised by the buildup of CO2 and other greenhouse gases in the atmosphere (IPCC, Third assessment report: Climate Change 2001. A contribution of working group I, II and III to the Third Assessment Report of the Intergovernmental Panel on Climate Change (Cambridge Univ. Press, UK) 2001, http://www.ipcc.ch) as these may affect the THC conveyor paths. Since it is widely recognized that dense-water formation sites act as primary sources in strengthening quasi-stable THC paths (Stommel H., Tellus131961224), in order to simulate properly the consequences of such scenarios a better understanding of these oceanic processes is needed. To successfully model these processes, air-sea-ice-integrated modelling approaches are often required. Here we focus on two polar regions using the Regional Ocean Modeling System (ROMS). In the first region investigated, the North Atlantic-Arctic, where open-ocean deep convection and open-sea ice formation and dispersion under the intense air-sea interactions are the major engines, we use a new version of the coupled hydrodynamic-ice ROMS model. The second area belongs to the Antarctica region inside the Southern Ocean, where brine rejections during ice formation inside shelf seas origin dense water that, flowing along the continental slope, overflow becoming eventually abyssal waters. Results show how nowadays integrated-modelling tasks have become more and more feasible and effective; numerical simulations dealing with large computational domains or challenging different climate scenarios can be run on multi-processors platforms and on systems like LINUX clusters, made of the same hardware as PCs, and codes have been accordingly modified.This relevant numerical help coming from the computer science can now allow scientists to devote larger attention in the efforts of understanding the deep mechanisms of such complex processes.

  4. Evaluation of systemic redox states in patients carrying the MELAS A3243G mutation in mitochondrial DNA.

    PubMed

    Ikawa, Masamichi; Arakawa, Kenichiro; Hamano, Tadanori; Nagata, Miwako; Nakamoto, Yasunari; Kuriyama, Masaru; Koga, Yasutoshi; Yoneda, Makoto

    2012-01-01

    To clarify the change of systemic redox states in patients carrying the A3243G mutation in mitochondrial DNA (A3243G), we evaluated oxidative stress and antioxidant activity in the serum of patients. Oxidative stress and antioxidant activity in the serum samples obtained from 14 patients carrying A3243G and from 34 healthy controls were analyzed using the diacron-reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) tests, respectively. The mean d-ROMs level of all patients was significantly greater than that of the controls (p < 0.005), and the mean BAP/d-ROMs ratio of all patients was significantly lower than that of the controls (p < 0.02). In the patients with a history of stroke-like episodes (n = 10), both mean d-ROMs and BAP levels were increased compared with those of the controls (both p < 0.01). The mean BAP level of the patients without a history of stroke-like episodes (n = 4) was significantly decreased compared with that of the controls (p < 0.001), but the mean d-ROMs levels were not significantly different. d-ROMs and BAP tests indicated that patients carrying A3243G are always exposed to underlying oxidative stress, even at a remission state of stroke-like episodes. Copyright © 2012 S. Karger AG, Basel.

  5. Sharing from Scratch: How To Network CD-ROM.

    ERIC Educational Resources Information Center

    Doering, David

    1998-01-01

    Examines common CD-ROM networking architectures: via existing operating systems (OS), thin server towers, and dedicated servers. Discusses digital video disc (DVD) and non-CD/DVD optical storage solutions and presents case studies of networks that work. (PEN)

  6. [Does routine outcome monitoring have a promising future? An investigation into the use of shared decision-making combined with ROM for patients with a combination of physical and psychiatric symptoms].

    PubMed

    van der Feltz-Cornelis, C M; Andrea, H; Kessels, E; Duivenvoorden, H J; Biemans, H; Metz, M

    2014-01-01

    Although routine outcome monitoring (ROM) has been developed and widely used in the course of patient centered outcome research in the Netherlands, so far the technique has hardly ever been used to improve the treatment of individual patients. To describe how a rom technique based on the principles of shared decision-making (SDM) was developed and evaluated at the Center for Body, Mind and Health at GGz Breburg, a specialised mental health institution in the Netherlands. We have developed a conceptual model for SDM that involves patient participation and the use of evidence-based decision-aids with cut-off scores. According to the conceptual model for SDM that we developed, the patient and the health professional involved took 'shared' decisions in three phases; the decisions related to triage, the drawing-up of a treatment plan and a follow-up treatment course. At the end of the 6 month intake-phase 7 of the 67 patients who were deemed eligible for ROM/SDM were dropped from the study because they were incapable of performing ROM assessments. Due to diagnostic advice and referral at the end of the intake-phase, 25 patients did not require further treatment. Of the remaining 35 patients, 33 delivered at least one follow-up ROM assessment during the subsequent treatment phases. In these patients somatic and psychiatric symptoms were found to be significantly reduced. ROM combined with sdm can be used successfully with patients who have a combination of physical and psychiatric symptoms and the technique can be applied by the professional in charge. Very few patients dropped out of the follow-up measurements and somatic as well as depressive or psychiatric symptoms diminished significantly. These findings indicate that a Randomised Clinical Trial is warranted in order to test the effectiveness of sdm combined with ROM as a decision-making instrument.

  7. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    PubMed

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI joint dysfunction significantly reduces the ROM of the treated side, but does not significantly reduce the ROM of the nontreated contralateral SI joint. Bilateral stabilization is necessary to significantly reduce the ROM for both SI joints.

  8. Monitoring patron use of CD-ROM databases using SignIn-Stat.

    PubMed Central

    Silver, H; Dennis, S

    1990-01-01

    SignIn-Stat, a PC-based, menu-driven program, collects information from users of the library's public access computer systems. It was used to collect patron use data for the library's four CD-ROM workstations for the period September 1987 to April 1988 and to survey users for the period December 1987 to March 1988. During the sample period, 5,909 CD-ROM uses were recorded. MEDLINE was the most heavily used database, followed by PsycLIT and Micromedex CCIS. Students accounted for 61% of the use, while faculty, residents, and staff were responsible for 31%. Graduate students had the highest rate of use per student. Nineteen percent of use was by patrons who had never used CD-ROMs before, while 37% was by patrons who had used CD-ROMs ten or more times. Residents were the least experienced user group, while graduate students and faculty were the most experienced. PMID:2203498

  9. Microcomputing.

    ERIC Educational Resources Information Center

    Beiser, Karl

    1986-01-01

    Describes a product--BiblioFile, Library Corporation's catalog production system--and a service--reproduction of public domain software on CD-ROM for sale to those interested--which revolve around the ultra-high-density storage capacity of CD-ROM discs. Criteria for selecting microcomputers are briefly reviewed. (MBR)

  10. Ankle-Dorsiflexion Range of Motion and Landing Biomechanics

    PubMed Central

    Fong, Chun-Man; Blackburn, J. Troy; Norcross, Marc F.; McGrath, Melanie; Padua, Darin A.

    2011-01-01

    Abstract Context: A smaller amount of ankle-dorsiflexion displacement during landing is associated with less knee-flexion displacement and greater ground reaction forces, and greater ground reaction forces are associated with greater knee-valgus displacement. Additionally, restricted dorsiflexion range of motion (ROM) is associated with greater knee-valgus displacement during landing and squatting tasks. Because large ground reaction forces and valgus displacement and limited knee-flexion displacement during landing are anterior cruciate ligament (ACL) injury risk factors, dorsiflexion ROM restrictions may be associated with a greater risk of ACL injury. However, it is unclear whether clinical measures of dorsiflexion ROM are associated with landing biomechanics. Objective: To evaluate relationships between dorsiflexion ROM and landing biomechanics. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty-five healthy, physically active volunteers. Intervention(s): Passive dorsiflexion ROM was assessed under extended-knee and flexed-knee conditions. Landing biomechanics were assessed via an optical motion-capture system interfaced with a force plate. Main Outcome Measure(s): Dorsiflexion ROM was measured in degrees using goniometry. Knee-flexion and knee-valgus displacements and vertical and posterior ground reaction forces were calculated during the landing task. Simple correlations were used to evaluate relationships between dorsiflexion ROM and each biomechanical variable. Results: Significant correlations were noted between extended-knee dorsiflexion ROM and knee-flexion displacement (r  =  0.464, P  =  .029) and vertical (r  =  −0.411, P  =  .014) and posterior (r  =  −0.412, P  =  .014) ground reaction forces. All correlations for flexed-knee dorsiflexion ROM and knee-valgus displacement were nonsignificant. Conclusions: Greater dorsiflexion ROM was associated with greater knee-flexion displacement and smaller ground reaction forces during landing, thus inducing a landing posture consistent with reduced ACL injury risk and limiting the forces the lower extremity must absorb. These findings suggest that clinical techniques to increase plantar-flexor extensibility and dorsiflexion ROM may be important additions to ACL injury-prevention programs. PMID:21214345

  11. Motion deficit in nodal interphalangeal joint osteoarthritis by digital goniometer in housewives.

    PubMed

    Ventura-Ríos, L; Hayes-Salinas, M; Ferrusquia-Toriz, D; Cariño-Escobar, R I; Cruz-Arenas, E; Gutiérrez-Martínez, J; González-Ramírez, L; Hernández-Díaz, C

    2018-06-01

    Range of motion (ROM) measured objectively in nodal hand osteoarthritis (NHOA) is missing. Evaluation of collateral ligaments by ultrasound (US) is unknown in NHOA also. To compare ROM in interphalangeal joints in housewives with nodal OA, with a control group by a digital system using angle to voltage (Multielgon). The second objective was to assess correlation between collateral radial and ulnar ligaments thickness and ROM. For this cross-sectional observational study, we assessed 60 hands with symptomatic NHOA and 30 hands of healthy housewives matched for age. We obtained clinical and demographic characteristics (a complete standardized physical examination of hand joints, DASH questionnaire, pain surveys, gross grasp hand goniometer, and ROM measurements by Multielgon. Presence of synovitis, power Doppler signal, osteophytes, and collateral ligaments thickness was evaluated by US. We used descriptive statistics, Spearman correlation, X 2 test, t test and odds ratio. Significant less gross grasp and ROM in the right hand were observed in NHOA (p = 0.01 for both). Presence of OA, painful joints, disease duration, and score DASH were significant correlated with reduced ROM (OR 4.12, 4.12, 1.04 and 1.09, respectively). Reduced ROM was statistical significant in thumb MCP and IP joints, second and third DIP in dominant hand. There was no association between collateral radial and ulnar ligaments and reduced ROM. Synovitis and osteophytes were more prevalent in OA group. Multielgon demonstrated the pattern of reduced ROM in nodal OA of housewives particularly in MCP and IP thumb joints, second and third distal interphalangeal joints.

  12. Reduced Order Model Basis Vector Generation: Generates Basis Vectors fro ROMs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arrighi, Bill

    2016-03-03

    libROM is a library that implements order reduction via singular value decomposition (SVD) of sampled state vectors. It implements 2 parallel, incremental SVD algorithms and one serial, non-incremental algorithm. It also provides a mechanism for adaptive sampling of basis vectors.

  13. The Basic Economics of CD-ROM Pricing.

    ERIC Educational Resources Information Center

    Erkkila, John E.

    1991-01-01

    This explanation of how the basic economic model of pricing applies to the CD-ROM industry considers the supply and demand sides of the market and compares three distinct pricing strategies: (1) pricing to maximize profits; (2) average cost pricing; and (3) marginal cost pricing. (EAM)

  14. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Nakaike, Shin'ichi; Tanaka, Masao

    The authors describe present status of patent information service by JAPIO, new on-line system project (PATOLIS-III), Paperless Project by the Patent Office and input of domestic gazettes for patent into optical disks. They also describe CD-ROM created by using image information of the gazettes for patent which is produced under the Paperless Project, its production method, and the terminals and their functions. Some problems found in CD-ROM of JAPIO, such as time lag for the issuance, treatment of the multiple copies, and countermeasures against them are mentioned.

  15. Two-dimensional ultrahigh-density X-ray optical memory.

    PubMed

    Bezirganyan, Hakob P; Bezirganyan, Siranush E; Bezirganyan, Hayk H; Bezirganyan, Petros H

    2007-01-01

    Most important aspect of nanotechnology applications in the information ultrahigh storage is the miniaturization of data carrier elements of the storage media with emphasis on the long-term stability. Proposed two-dimensional ultrahigh-density X-ray optical memory, named X-ROM, with long-term stability is an information carrier basically destined for digital data archiving. X-ROM is a semiconductor wafer, in which the high-reflectivity nanosized X-ray mirrors are embedded. Data are encoded due to certain positions of the mirrors. Ultrahigh-density data recording procedure can e.g., be performed via mask-less zone-plate-array lithography (ZPAL), spatial-phase-locked electron-beam lithography (SPLEBL), or focused ion-beam lithography (FIB). X-ROM manufactured by nanolithography technique is a write-once memory useful for terabit-scale memory applications, if the surface area of the smallest recording pits is less than 100 nm2. In this case the X-ROM surface-storage capacity of a square centimetre becomes by two orders of magnitude higher than the volumetric data density really achieved for three-dimensional optical data storage medium. Digital data read-out procedure from proposed X-ROM can e.g., be performed via glancing-angle incident X-ray micro beam (GIX) using the well-developed X-ray reflectometry technique. In presented theoretical paper the crystal-analyser operating like an image magnifier is added to the set-up of X-ROM data handling system for the purpose analogous to case of application the higher numerical aperture objective in optical data read-out system. We also propose the set-up of the X-ROM readout system based on more the one incident X-ray micro beam. Presented scheme of two-beam data handling system, which operates on two mutually perpendicular well-collimated monochromatic incident X-ray micro beams, essentially increases the reliability of the digital information read-out procedure. According the graphs of characteristic functions presented in paper, one may choose optimally the incident radiation wavelength, as well as the angle of incidence of X-ray micro beams, appropriate for proposed digital data read-out procedure.

  16. Selected Conference Proceedings from the 1985 Videodisc, Optical Disk, and CD-ROM Conference and Exposition (Philadelphia, PA, December 10-12, 1985).

    ERIC Educational Resources Information Center

    Cerva, John R.; And Others

    1986-01-01

    Eight papers cover: optical storage technology; cross-cultural videodisc design; optical disk technology use at the Library of Congress Research Service and National Library of Medicine; Internal Revenue Service image storage and retrieval system; solving business problems with CD-ROM; a laser disk operating system; and an optical disk for…

  17. Artificial Intelligence-Explosive Ordnance Disposal Information Search, Retrieval, and Delivery System

    DTIC Science & Technology

    1992-04-01

    megabytes greater than required to store the operating system and X-Windows. * CD-ROM Player. Standard CD-ROM player using ISO 9660 file format...CAVGERRO 235 .4596 . 8583 .0000 4.0000 42 CAVGFOUN 235 3.9362 .3700 .0000 4.0000 43 SlIT 235 172.3106 207.4205 .0000 1039.0000 44 S2T 235 122.0638

  18. An Investigation into the Economics of Retrospective Conversion Using a CD-ROM System.

    ERIC Educational Resources Information Center

    Co, Francisca K.

    This study compares the cost effectiveness of using a CD-ROM (compact disk read-only memory) system known as Bibliofile and the currently used OCLC (Online Computer Library Center)-based method to convert a university library's shelflist into a machine-readable database in the MARC (Machine-Readable Cataloging) format. The cost of each method of…

  19. Prehospital emergency removal of football helmets using two techniques.

    PubMed

    Swartz, Erik E; Hernandez, Adam E; Decoster, Laura C; Mihalik, Jason P; Burns, Matthew F; Reynolds, Cathryn

    2011-01-01

    To compare the Eject Helmet Removal (EHR) System with manual football helmet removal. This quasiexperimental counterbalanced study was conducted in a controlled laboratory setting. Thirty certified athletic trainers (17 men and 13 women; mean ± standard deviation age: 33.03 ± 10.02 years; height: 174.53 ± 12.04 cm; mass: 85.19 ± 19.84 kg) participated after providing informed consent. Participants removed a Riddell Revolution IQ football helmet from a healthy model two times each under two conditions: manual helmet removal (MHR) and removal with the EHR system. A six-camera, three-dimensional motion capture system was used to record range of motion (ROM) of the head. A digital stopwatch was used to time trials and to record a split time associated with EHR system bladder insertion. A modified Borg CR10 scale was used to measure the rating of perceived exertion (RPE). Mean values were created for each variable. Three pairwise t-tests with Bonferroni-corrected alpha levels tested for differences between time for removal, split time, and RPE. A 2 x 3 (condition x plane) totally within-subjects repeated-measures design analysis of variance (ANOVA) tested for differences in head ROM between the sagittal, frontal, and transverse planes. Analyses were performed using SPSS (version 18.0) (alpha = 0.05). There was no statistically significant difference in perceived difficulty between EHR (RPE = 2.73) and MHR (RPE = 2.55) (t(29) = 0.76; p = 0.45; d = 0.20). Manual helmet removal was, on average, 28.95 seconds faster than EHR (t(29) = 11.44; p < 0.001). Head ROM was greater during EHR compared with MHR in the sagittal (t(29) = 4.57; p < 0.001), frontal (t(29) = 5.90; p < 0.001), and transverse (t(29) = 8.34; p < 0.001) planes. Head ROM was also greater during the helmet-removal portion of EHR in the frontal (t(29) = 4.44; p < 0.001) and transverse (t(29) = 5.99; p < 0.001) planes, compared with MHR. Regardless of technique, sagittal-plane head ROM was greater than frontal- and transverse-plane movements (F(2,58) = 241.47; p < 0.001). Removing a helmet manually is faster and creates slightly less motion than removing a helmet using the Eject system. Both techniques were equally easy to use. Future research should analyze the performance of the Eject system in other styles of football helmets and in helmets used in other sports such as lacrosse, motorsports, and ice hockey.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pau, G. S. H.; Bisht, G.; Riley, W. J.

    Existing land surface models (LSMs) describe physical and biological processes that occur over a wide range of spatial and temporal scales. For example, biogeochemical and hydrological processes responsible for carbon (CO 2, CH 4) exchanges with the atmosphere range from the molecular scale (pore-scale O 2 consumption) to tens of kilometers (vegetation distribution, river networks). Additionally, many processes within LSMs are nonlinearly coupled (e.g., methane production and soil moisture dynamics), and therefore simple linear upscaling techniques can result in large prediction error. In this paper we applied a reduced-order modeling (ROM) technique known as "proper orthogonal decomposition mapping method" thatmore » reconstructs temporally resolved fine-resolution solutions based on coarse-resolution solutions. We developed four different methods and applied them to four study sites in a polygonal tundra landscape near Barrow, Alaska. Coupled surface–subsurface isothermal simulations were performed for summer months (June–September) at fine (0.25 m) and coarse (8 m) horizontal resolutions. We used simulation results from three summer seasons (1998–2000) to build ROMs of the 4-D soil moisture field for the study sites individually (single-site) and aggregated (multi-site). The results indicate that the ROM produced a significant computational speedup (> 10 3) with very small relative approximation error (< 0.1%) for 2 validation years not used in training the ROM. We also demonstrate that our approach: (1) efficiently corrects for coarse-resolution model bias and (2) can be used for polygonal tundra sites not included in the training data set with relatively good accuracy (< 1.7% relative error), thereby allowing for the possibility of applying these ROMs across a much larger landscape. By coupling the ROMs constructed at different scales together hierarchically, this method has the potential to efficiently increase the resolution of land models for coupled climate simulations to spatial scales consistent with mechanistic physical process representation.« less

  1. The sagittal stem alignment and the stem version clearly influence the impingement-free range of motion in total hip arthroplasty: a computer model-based analysis.

    PubMed

    Müller, Michael; Duda, Georg; Perka, Carsten; Tohtz, Stephan

    2016-03-01

    The component alignment in total hip arthroplasty influences the impingement-free range of motion (ROM). While substantiated data is available for the cup positioning, little is known about the stem alignment. Especially stem rotation and the sagittal alignment influence the position of the cone in relation to the edge of the socket and thus the impingement-free functioning. Hence, the question arises as to what influence do these parameters have on the impingement-free ROM? With the help of a computer model the influence of the sagittal stem alignment and rotation on the impingement-free ROM were investigated. The computer model was based on the CT dataset of a patient with a non-cemented THA. In the model the stem version was set at 10°/0°/-10° and the sagittal alignment at 5°/0°/-5°, which resulted in nine alternative stem positions. For each position, the maximum impingement-free ROM was investigated. Both stem version and sagittal stem alignment have a relevant influence on the impingement-free ROM. In particular, flexion and extension as well as internal and external rotation capability present evident differences. In the position intervals of 10° sagittal stem alignment and 20° stem version a difference was found of about 80° in the flexion and 50° in the extension capability. Likewise, differences were evidenced of up to 72° in the internal and up to 36° in the external rotation. The sagittal stem alignment and the stem torsion have a relevant influence on the impingement-free ROM. To clarify the causes of an impingement or accompanying problems, both parameters should be examined and, if possible, a combined assessment of these factors should be made.

  2. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Keiji, Ogawa

    Toppan Printing Co., Ltd. has played a pioneering role in developing CTS (Computerized Typesetting System) for these twenty years, and has accumulated a great deal of technical know-how. The company intends to integrate accumulated information into multimedia. As for CD-ROM, it has been aggressively striven to develop, from planning to data-input and data-processing. Recently, under the guidance of Research group on molecular design, It has developed a CD-ROM system to support research and development in the field of organic chemistry. This system is constructed mainly of the data in “Organic Syntheses”, a bible among organic chemists. The outline of the structure of files, and that of indexes which is a key point in retrieval, the flow chart of the retrieval process, and editing processes, etc. are described in this paper.

  3. CD-ROM End-User Instruction: A Planning Model.

    ERIC Educational Resources Information Center

    Johnson, Mary E.; Rosen, Barbara S.

    1990-01-01

    Discusses methods and content of library instruction for CD-ROM searching in terms of the needs of end-users. Instructional methods explored include staff instruction, structured instruction, database documentation, tutorials and help screens, and floaters. Suggestions for effective instruction in transfer of skills, database content, database…

  4. Crocodile Mathematics 1.1. [CD-ROM].

    ERIC Educational Resources Information Center

    2002

    This CD-ROM consists of software that allows both teachers and students to create and experiment with mathematical models by linking shapes, graphs, numbers, and equations. It is usable for demonstrations, home learning, reinforcing concepts, illustrating concepts that are difficult to visualize, further pupil investigations, and project work.…

  5. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  6. Mineral Resources Data System (MRDS)

    USGS Publications Warehouse

    Mason, G.T.; Arndt, R.E.

    1996-01-01

    The U.S. Geological Survey (USGS) operates the Mineral Resources Data System (MRDS), a digital system that contained 111,955 records on Sept. 1, 1995. Records describe metallic and industrial commodity deposits, mines, prospects, and occurrences in the United States and selected other countries. These records have been created over the years by USGS commodity specialists and through cooperative agreements with geological surveys of U.S. States and other countries. This CD-ROM contains the complete MRDS data base, several subsets of it, and software to allow data retrieval and display. Data retrievals are made by using GSSEARCH, a program that is included on this CD-ROM. Retrievals are made by specifying fields or any combination of the fields that provide information on deposit name, location, commodity, deposit model type, geology, mineral production, reserves, and references. A tutorial is included. Retrieved records may be printed or written to a hard disk file in four different formats: ascii, fixed, comma delimited, and DBASE compatible.

  7. A numerical investigation of the Southern Gyre using ROMS

    NASA Astrophysics Data System (ADS)

    Gamoyo, Majambo; Reason, Chris J. C.; Collins, Charine

    2017-05-01

    A numerical model (The Regional Ocean Modelling System-ROMS), configured over the western Indian Ocean and driven by monthly climatology winds and heat fluxes, is applied to examine the Southern Gyre in the Somali Current system during the Southwest Monsoon. Despite the Southern Gyre playing a role in transporting water masses and other properties northwards across the equator, it has not been much studied. The model results indicate that the Southern Gyre appears in early June in the upper ocean as a result of instability in the northward flowing Somali Current. The arrival of downwelling Rossby wave energy at the East African coast intensifies the recirculation of the Southern Gyre and causes its northward movement. The Southern Gyre is characterized as a shallow feature which deepens from 100 m in June to 300 m in July-August. The average spatial scale of the gyre is about 400 km with subsequent development of positive vorticity bursts which are identified as potential contributors to the decay of the Southern Gyre. Cool and fresh waters observed in the gyre resulted from advection via the South Equatorial Current and then through the Somali Current (SC).

  8. The impact of high-heeled shoes on ankle complex during walking in young women-In vivo kinematic study based on 3D to 2D registration technique.

    PubMed

    Wang, Chen; Geng, Xiang; Wang, Shaobai; Ma, Xin; Wang, Xu; Huang, Jiazhang; Zhang, Chao; Chen, Li; Yang, Junsheng; Li, Jiabei; Wang, Kan

    2016-06-01

    To explore the accurate in vivo kinematic changes in the ankle complex when wearing low- and high-heel shoes (LHS and HHS, respectively). Twelve young women were tested unilaterally. Three-dimensional models of the tibia, talus, and calcaneus were first created based on CT scan results. The subjects walked at a self-controlled speed in barefoot, LHS (4cm), and HHS (10cm) conditions. A fluoroscopy system captured the lateral fluoroscopic images of the ankle complex. The images of seven key positions in the stance phase were selected, and 3D to 2D bone model registrations were performed to determine the joint positions. The mean of 6 degree of freedom (DOF) range of motions (ROM), joint positions, and angular displacements of the ankle complex during the gait were then obtained. For the talocrural joint, the rotational ROMs of the subjects either in LHS or HHS condition displayed no significant difference from those in barefoot condition. For the subtalar joint, all the rotational ROMs in the HHS condition and the internal/external rotations in the LHS condition significantly decreased compared with those in the barefoot condition. The talocrural joint was positioned significantly more plantarflexed, inverted, internally rotated, and posteriorly seated in all seven poses in HHS condition, compared with those in barefoot condition. HHS mainly affected the rotational motion of the ankle complex during walking. The talocrural joint position was abnormal, and the subtalar joint ROM decreased during the gait in HHS condition. Only a few kinematic changes occurred in LHS condition relative to the barefoot condition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Potential utility of three-dimensional temperature and salinity fields estimated from satellite altimetry and Argo data for improving mesoscale reproducibility in regional ocean modeling

    NASA Astrophysics Data System (ADS)

    Kanki, R.; Uchiyama, Y.; Miyazaki, D.; Takano, A.; Miyazawa, Y.; Yamazaki, H.

    2014-12-01

    Mesoscale oceanic structure and variability are required to be reproduced as accurately as possible in realistic regional ocean modeling. Uchiyama et al. (2012) demonstrated with a submesoscale eddy-resolving JCOPE2-ROMS downscaling oceanic modeling system that the mesoscale reproducibility of the Kuroshio meandering along Japan is significantly improved by introducing a simple restoration to data which we call "TS nudging" (a.k.a. robust diagnosis) where the prognostic temperature and salinity fields are weakly nudged four-dimensionally towards the assimilative JCOPE2 reanalysis (Miyazawa et al., 2009). However, there is not always a reliable reanalysis for oceanic downscaling in an arbitrary region and at an arbitrary time, and therefore alternative dataset should be prepared. Takano et al. (2009) proposed an empirical method to estimate mesoscale 3-D thermal structure from the near real-time AVISO altimetry data along with the ARGO float data based on the two-layer model of Goni et al. (1996). In the present study, we consider the TS data derived from this method as a candidate. We thus conduct a synoptic forward modeling of the Kuroshio using the JCOPE2-ROMS downscaling system to explore potential utility of this empirical TS dataset (hereinafter TUM-TS) by carrying out two runs with the T-S nudging towards 1) the JCOPE2-TS and 2) TUM-TS fields. An example of the comparison between the two ROMS test runs is shown in the attached figure showing the annually averaged surface EKE. Both of TUM-TS and JCOPE2-TS are found to help reproducing the mesoscale variance of the Koroshio and its extension as well as its mean paths, surface KE and EKE reasonably well. Therefore, the AVISO-ARGO derived empirical 3-D TS estimation is potentially exploitable for the dataset to conduct the T-S nudging to reproduce mesoscale oceanic structure.

  10. Oxidative stress in obesity and metabolic syndrome in children and adolescents.

    PubMed

    Faienza, Maria Felicia; Francavilla, Ruggiero; Goffredo, Rocco; Ventura, Annamaria; Marzano, Flaviana; Panzarino, Gianvito; Marinelli, Grazia; Cavallo, Luciano; Di Bitonto, Giovanna

    2012-01-01

    The aim of this study was to investigate the alterations in the oxidant/antioxidant status in obese children with and without metabolic syndrome (MetS). We recruited 25 Caucasian obese children with MetS, 30 Caucasian children with simple obesity and a control group of 30 Caucasian children. We performed diacron-reactive oxygen metabolites (d-ROMs) test and biological antioxidant potential (BAP) test in order to evaluate the oxidant-antioxidant status in recruited patients. d-ROM level was significantly higher in obese children with and without MetS (p = 0.005). The total antioxidant capacity (BAP level) was reduced in MetS and noMetS children compared to controls (p = 0.009). The subjects without MetS had higher d-ROMs test and lower BAP/d-ROMs ratio than subjects with MetS (although not significant). The ratio BAP/d-ROMs was higher in controls than noMetS and MetS children (p < 0.0001). d-ROM level was higher in prepubertal subjects with MetS than pubertal ones (p = 0.03). A direct correlation was found between d-ROM levels and BMI SDS (p = 0.0005), while an inverse correlation was found between BAP and BMI SDS (p = 0.004) and BAP/d-ROMs and BMI SDS (p = 0.0001). This result confirms that fat accumulation plays a key role in the pathogenesis of systemic oxidative stress already during pediatric age. Copyright © 2012 S. Karger AG, Basel.

  11. Serum derivative of reactive oxygen metabolites (d-ROMs) in pediatric hemato-oncological patients with neutropenic fever.

    PubMed

    Nishikawa, Takuro; Okamoto, Yasuhiro; Kodama, Yuichi; Tanabe, Takayuki; Shinkoda, Yuichi; Kawano, Yoshifumi

    2010-07-15

    Early markers for predicting the severity of neutropenic fever (NF) in patients with hemato-oncological patients have not yet been established. Reactive oxygen species are known to play an important role in the antimicrobial function of neutrophils. The aim of this study was to determine the serum levels of derivatives of reactive oxygen metabolites (d-ROMs) and the biological antioxidant potential (BAP) levels in these patients, and to investigate the associations between these levels and the severity of NF. Twenty-seven pediatric hemato-oncological patients were enroled in this prospective study. Their median age was 10 years (range 1-19). Laboratory samples for C-reactive protein (CRP), d-ROMs, and BAP were collected at the onset of NF. The Free Radical Analytical System 4(R) was used to measure levels of d-ROMs and BAP. A total 36 NF episodes were evaluated. Levels of d-ROMs in NF patients with systemic inflammatory response syndrome (SIRS, n = 7) were significantly lower than those in subjects without SIRS (n = 29; 197.6 vs. 314.1 U.CARR, P = 0.017). There were no statistically significant differences in CRP, BAP, WBC count, or neutrophil count at the onset. The peak levels of CRP were significantly higher in patients with SIRS than in those without SIRS (23.9 vs. 6.1 mg/dl, P = 0.0003). Patients with low level of d-ROMs at the onset of NF should be observed stringently since they possibly have severe NF.

  12. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Kusama, Hideo; Matsumoto, Toshiaki

    The CD-ROM system can be used independently or as a compliment to an on-line data system. It has many of the same features as an on-line system. Nippan developed the CD-NOCS system as a reinforcement or substitute for the on-line systems of the customers (bookstores). CD-NOCS is not necessarily designed just for bookstores, it is also applicable to libraries and companies. Authors would also like to emphasize that it is important to understand the development and background of the CD-NOCS system, as well as its operations.

  13. Minimal subspace rotation on the Stiefel manifold for stabilization and enhancement of projection-based reduced order models for the compressible Navier–Stokes equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balajewicz, Maciej; Tezaur, Irina; Dowell, Earl

    For a projection-based reduced order model (ROM) of a fluid flow to be stable and accurate, the dynamics of the truncated subspace must be taken into account. This paper proposes an approach for stabilizing and enhancing projection-based fluid ROMs in which truncated modes are accounted for a priori via a minimal rotation of the projection subspace. Attention is focused on the full non-linear compressible Navier–Stokes equations in specific volume form as a step toward a more general formulation for problems with generic non-linearities. Unlike traditional approaches, no empirical turbulence modeling terms are required, and consistency between the ROM and themore » Navier–Stokes equation from which the ROM is derived is maintained. Mathematically, the approach is formulated as a trace minimization problem on the Stiefel manifold. As a result, the reproductive as well as predictive capabilities of the method are evaluated on several compressible flow problems, including a problem involving laminar flow over an airfoil with a high angle of attack, and a channel-driven cavity flow problem.« less

  14. Minimal subspace rotation on the Stiefel manifold for stabilization and enhancement of projection-based reduced order models for the compressible Navier–Stokes equations

    DOE PAGES

    Balajewicz, Maciej; Tezaur, Irina; Dowell, Earl

    2016-05-25

    For a projection-based reduced order model (ROM) of a fluid flow to be stable and accurate, the dynamics of the truncated subspace must be taken into account. This paper proposes an approach for stabilizing and enhancing projection-based fluid ROMs in which truncated modes are accounted for a priori via a minimal rotation of the projection subspace. Attention is focused on the full non-linear compressible Navier–Stokes equations in specific volume form as a step toward a more general formulation for problems with generic non-linearities. Unlike traditional approaches, no empirical turbulence modeling terms are required, and consistency between the ROM and themore » Navier–Stokes equation from which the ROM is derived is maintained. Mathematically, the approach is formulated as a trace minimization problem on the Stiefel manifold. As a result, the reproductive as well as predictive capabilities of the method are evaluated on several compressible flow problems, including a problem involving laminar flow over an airfoil with a high angle of attack, and a channel-driven cavity flow problem.« less

  15. On the POD based reduced order modeling of high Reynolds flows

    NASA Astrophysics Data System (ADS)

    Behzad, Fariduddin; Helenbrook, Brian; Ahmadi, Goodarz

    2012-11-01

    Reduced-order modeling (ROM) of a high Reynolds fluid flow using the proper orthogonal decomposition (POD) was studied. Particular attention was given to incompressible, unsteady flow over a two-dimensional NACA0015 airfoil. The Reynolds number is 105 and the angle of attacked of the airfoil is 12°. For DNS solution, hp-finite element method is employed to drive flow samples from which the POD modes are extracted. Particular attention is paid on two issues. First, the stability of POD-ROM resimulation of the turbulent flow is studied. High Reynolds flow contains a lot of fluctuating modes. So, to reach a certain amount of error, more POD modes are needed and the effect of truncation of POD modes is more important. Second, the role of convergence rate on the results of POD. Due to complexity of the flow, convergence of the governing equations is more difficult and the influences of weak convergence appear in the results of POD-ROM. For each issue, the capability of the POD-ROM is assessed in terms of predictions quality of times upon which the POD model was derived. The results are compared with DNS solution and the accuracy and efficiency of different cases are evaluated.

  16. Reduced-order modellin for high-pressure transient flow of hydrogen-natural gas mixture

    NASA Astrophysics Data System (ADS)

    Agaie, Baba G.; Khan, Ilyas; Alshomrani, Ali Saleh; Alqahtani, Aisha M.

    2017-05-01

    In this paper the transient flow of hydrogen compressed-natural gas (HCNG) mixture which is also referred to as hydrogen-natural gas mixture in a pipeline is numerically computed using the reduced-order modelling technique. The study on transient conditions is important because the pipeline flows are normally in the unsteady state due to the sudden opening and closure of control valves, but most of the existing studies only analyse the flow in the steady-state conditions. The mathematical model consists in a set of non-linear conservation forms of partial differential equations. The objective of this paper is to improve the accuracy in the prediction of the HCNG transient flow parameters using the Reduced-Order Modelling (ROM). The ROM technique has been successfully used in single-gas and aerodynamic flow problems, the gas mixture has not been done using the ROM. The study is based on the velocity change created by the operation of the valves upstream and downstream the pipeline. Results on the flow characteristics, namely the pressure, density, celerity and mass flux are based on variations of the mixing ratio and valve reaction and actuation time; the ROM computational time cost advantage are also presented.

  17. The Role of Environmental Forcing in Controlling Water Retention Gyres in Subsystems of Narragansett Bay

    NASA Astrophysics Data System (ADS)

    Balt, C.; Kincaid, C. R.; Ullman, D. S.

    2010-12-01

    Greenwich Bay and the Providence River represent two subsystems of the Narragansett Bay (RI) estuary with chronic water quality problems. Both underway and moored Acoustic Doppler Current Profiler (ADCP) observations have shown the presence of large-scale, subtidal gyres within these subsystems. Prior numerical models of Narragansett Bay, developed using the Regional Ocean Modeling System (ROMS), indicate that prevailing summer sea breeze conditions are favorable to the evolution of stable circulation gyres, which increase retention times within each subsystem. Fluid dynamics laboratory models of the Providence River, conducted in the Geophysical Fluid Dynamics Laboratory of the Research School of Earth Sciences (Australian National University), reproduce gyres that match first order features of the ADCP data. These laboratory models also reveal details of small-scale eddies along the edges of the retention gyre. We report results from spatially and temporally detailed current meter deployments (using SeaHorse Tilt Current Meters) in both subsystems, which reveal details on the growth and decay of gyres under various spring-summer forcing conditions. In particular, current meters were deployed during the severe flooding events in the Narragansett Bay watershed during March, 2010. A combination of current meter data and high-resolution ROMS modeling is used to show how gyres effectively limit subtidal exchange from the Providence River and Greenwich Bay and to understand the forcing conditions that favor efficient flushing. The residence times of stable gyres within these regions can be an order of magnitude larger than values predicted by fraction of water methods. ROMS modeling is employed to characterize gyre energy, stability, and flushing rates for a wide range of seasonal, wind and runoff scenarios.

  18. Machine learning to construct reduced-order models and scaling laws for reactive-transport applications

    NASA Astrophysics Data System (ADS)

    Mudunuru, M. K.; Karra, S.; Vesselinov, V. V.

    2017-12-01

    The efficiency of many hydrogeological applications such as reactive-transport and contaminant remediation vastly depends on the macroscopic mixing occurring in the aquifer. In the case of remediation activities, it is fundamental to enhancement and control of the mixing through impact of the structure of flow field which is impacted by groundwater pumping/extraction, heterogeneity, and anisotropy of the flow medium. However, the relative importance of these hydrogeological parameters to understand mixing process is not well studied. This is partially because to understand and quantify mixing, one needs to perform multiple runs of high-fidelity numerical simulations for various subsurface model inputs. Typically, high-fidelity simulations of existing subsurface models take hours to complete on several thousands of processors. As a result, they may not be feasible to study the importance and impact of model inputs on mixing. Hence, there is a pressing need to develop computationally efficient models to accurately predict the desired QoIs for remediation and reactive-transport applications. An attractive way to construct computationally efficient models is through reduced-order modeling using machine learning. These approaches can substantially improve our capabilities to model and predict remediation process. Reduced-Order Models (ROMs) are similar to analytical solutions or lookup tables. However, the method in which ROMs are constructed is different. Here, we present a physics-informed ML framework to construct ROMs based on high-fidelity numerical simulations. First, random forests, F-test, and mutual information are used to evaluate the importance of model inputs. Second, SVMs are used to construct ROMs based on these inputs. These ROMs are then used to understand mixing under perturbed vortex flows. Finally, we construct scaling laws for certain important QoIs such as degree of mixing and product yield. Scaling law parameters dependence on model inputs are evaluated using cluster analysis. We demonstrate application of the developed method for model analyses of reactive-transport and contaminant remediation at the Los Alamos National Laboratory (LANL) chromium contamination sites. The developed method is directly applicable for analyses of alternative site remediation scenarios.

  19. Nonlinear model for an optical read-only-memory disk readout channel based on an edge-spread function.

    PubMed

    Kobayashi, Seiji

    2002-05-10

    A point-spread function (PSF) is commonly used as a model of an optical disk readout channel. However, the model given by the PSF does not contain the quadratic distortion generated by the photo-detection process. We introduce a model for calculating an approximation of the quadratic component of a signal. We show that this model can be further simplified when a read-only-memory (ROM) disk is assumed. We introduce an edge-spread function by which a simple nonlinear model of an optical ROM disk readout channel is created.

  20. Measuring Temporal Resolution (Release of Masking) with a Hughson-Westlake Up-Down Instead of a Békèsy-Tracking Procedure.

    PubMed

    Rhebergen, Koenraad S; van Esch, Thamar E M; Dreschler, Wouter A

    2015-06-01

    A temporal resolution test in addition to the pure-tone audiogram may be of great clinical interest because of its relevance in speech perception and expected relevance in hearing aid fitting. Larsby and Arlinger developed an appropriate clinical test, but this test uses a Békèsy-tracking procedure for estimating masked thresholds in stationary and interrupted noise to assess release of masking (RoM) for temporal resolution. Generally the Hughson-Westlake up-down procedure is used in the clinic to measure the pure-tone thresholds in quiet. A uniform approach will facilitate clinical application and might be appropriate for RoM measurements as well. Because there is no golden standard for measuring the RoM in the clinic, we examine in the present study the Hughson-Westlake up-down procedure to measure the RoM and compare the results with the Békèsy-tracking procedure. The purpose of the current study was to examine the differences between a Békèsy-tracking procedure and the Hughson-Westlake up-down procedure for estimating masked thresholds in stationary and interrupted noise to assess RoM. RoM is assessed in eight normal-hearing (NH) and ten hearing-impaired (HI) listeners through both methods. Results from both methods are compared with each other and with predicted thresholds from a model. Wilcoxon signed-rank tests, paired t tests. Some differences between the two methods were found. We used a model to quantify the results of the two measurement procedures. The results of the Hughson-Westlake procedure were clearly better in agreement with the model than the results of the Békèsy-tracking procedure. Furthermore, the Békèsy-tracking procedure showed more spread in the results of the NH listeners than the Hughson-Westlake procedure. The Hughson-Westlake procedure seems to be an applicable alternative for measuring RoM for temporal resolution in the clinical audiological practice. American Academy of Audiology.

  1. Virtual Knowledge: The Best Buys in 1998 CD-ROM Encyclopedias.

    ERIC Educational Resources Information Center

    Burg, Barbara; Kautzman, Amy M.

    1998-01-01

    Discusses questions to consider and features to look for in selecting a CD-ROM encyclopedia. Reviews Encyclopaedia Britannica CD 98 Multimedia Edition, Compton's Interactive Encyclopedia 1998, Microsoft Encarta 98 Encyclopedia, and Grolier Multimedia Encyclopedia 1998. Contact information, price, and system requirements are listed. (JAK)

  2. School Library Supplement. Putting Your Library Automation System to Work [and] Using Videodiscs in Research Projects [and] Library Security: What to Look For [and] Expanding Library/Media Services with Media Retrieval [and] How to Network CD-ROMs (and) The School Library Resource Directory.

    ERIC Educational Resources Information Center

    Karpisek, Marian; And Others

    1995-01-01

    Presents five articles and a company resource directory to help librarians successfully incorporate technology into school libraries. Discusses actual situations, examines student needs, and gives advice to help librarians with library automation systems, videodiscs, library security systems, media retrieval, networking CD-ROMs, and locating…

  3. 4DVAR data Assimilation with the Regional Ocean Modeling System (ROMS): Impact on the Water Mass Distributions in the Yellow Sea

    NASA Astrophysics Data System (ADS)

    Lee, Joon-Ho; Kim, Taekyun; Pang, Ig-Chan; Moon, Jae-Hong

    2018-04-01

    In this study, we evaluate the performance of the recently developed incremental strong constraint 4-dimensional variational (4DVAR) data assimilation applied to the Yellow Sea (YS) using the Regional Ocean Modeling System (ROMS). Two assimilation experiments are compared: assimilating remote-sensed sea surface temperature (SST) and both the SST and in-situ profiles measured by shipboard CTD casts into a regional ocean modeling from January to December of 2011. By comparing the two assimilation experiments against a free-run without data assimilation, we investigate how the assimilation affects the hydrographic structures in the YS. Results indicate that the SST assimilation notably improves the model behavior at the surface when compared to the nonassimilative free-run. The SST assimilation also has an impact on the subsurface water structure in the eastern YS; however, the improvement is seasonally dependent, that is, the correction becomes more effective in winter than in summer. This is due to a strong stratification in summer that prevents the assimilation of SST from affecting the subsurface temperature. A significant improvement to the subsurface temperature is made when the in-situ profiles of temperature and salinity are assimilated, forming a tongue-shaped YS bottom cold water from the YS toward the southwestern seas of Jeju Island.

  4. Hardware Implementation of 32-Bit High-Speed Direct Digital Frequency Synthesizer

    PubMed Central

    Ibrahim, Salah Hasan; Ali, Sawal Hamid Md.; Islam, Md. Shabiul

    2014-01-01

    The design and implementation of a high-speed direct digital frequency synthesizer are presented. A modified Brent-Kung parallel adder is combined with pipelining technique to improve the speed of the system. A gated clock technique is proposed to reduce the number of registers in the phase accumulator design. The quarter wave symmetry technique is used to store only one quarter of the sine wave. The ROM lookup table (LUT) is partitioned into three 4-bit sub-ROMs based on angular decomposition technique and trigonometric identity. Exploiting the advantages of sine-cosine symmetrical attributes together with XOR logic gates, one sub-ROM block can be removed from the design. These techniques, compressed the ROM into 368 bits. The ROM compressed ratio is 534.2 : 1, with only two adders, two multipliers, and XOR-gates with high frequency resolution of 0.029 Hz. These techniques make the direct digital frequency synthesizer an attractive candidate for wireless communication applications. PMID:24991635

  5. [ROM and the position of the health insurance companies].

    PubMed

    Laane, R; Luijk, R

    2012-01-01

    Up till 2008 the Dutch mental health services came under the Dutch General Law on Special Medical Costs (AWBZ). Health insurers regarded the mental health services as 'black box'. In 2008 the mental health services were transferred to the basic health insurance system and the health insurers became responsible for the healthcare purchasing services. In the same year the mental health services began to use ROM to measure the effects of treatment and thereby improve the quality of treatment. To clarify the use that the insurers make of ROM. The developments in this field are described. The feedback supplied by ROM enables therapists to improve treatment. An additional benefit is that the mental health services are then in a position to improve quality at aggregate level and compare their own results with those of others. Nationally, ROM can provide health insurers with information about treatment quality in combination with the Consumer Quality Index (CQI), and national 'benchmarks' can be implemented. To facilitate the interpretation of these rom data the health insurers set up the independent foundation, Stichting Benchmark GGZ (mental health care), in which GGZ Nederland has participated since 2010. ROM provides therapists with a means for improving treatment and provides insurers with a means by which they can express their views about the quality of the mental health services at aggregate level.

  6. Extension and flexion in the upper cervical spine in neck pain patients.

    PubMed

    Ernst, Markus J; Crawford, Rebecca J; Schelldorfer, Sarah; Rausch-Osthoff, Anne-Kathrin; Barbero, Marco; Kool, Jan; Bauer, Christoph M

    2015-08-01

    Neck pain is a common problem in the general population with high risk of ongoing complaints or relapses. Range of motion (ROM) assessment is scientifically established in the clinical process of diagnosis, prognosis and outcome evaluation in neck pain. Anatomically, the cervical spine (CS) has been considered in two regions, the upper and lower CS. Disorders like cervicogenic headache have been clinically associated with dysfunctions of the upper CS (UCS), yet ROM tests and measurements are typically conducted on the whole CS. A cross-sectional study assessing 19 subjects with non-specific neck pain was undertaken to examine UCS extension-flexion ROM in relation to self-reported disability and pain (via the Neck Disability Index (NDI)). Two measurement devices (goniometer and electromagnetic tracking) were employed and compared. Correlations between ROM and the NDI were stronger for the UCS compared to the CS, with the strongest correlation between UCS flexion and the NDI-headache (r = -0.62). Correlations between UCS and CS ROM were fair to moderate, with the strongest correlation between UCS flexion and CS extension ROM (r = -0.49). UCS flexion restriction is related to headache frequency and intensity. Consistency and agreement between both measurement systems and for all tests was high. The results demonstrate that separate UCS ROM assessments for extension and flexion are useful in patients with neck pain. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. CD-ROM in a High School Library Media Center.

    ERIC Educational Resources Information Center

    Barlow, Diane; And Others

    1987-01-01

    Describes the experiences of high school students using microcomputers to access an electronic version of an encyclopedia in the school's media center. The topics discussed include hardware and software requirements of the CD-ROM format, information seeking strategies and problems observed, student satisfaction with the system, and recommendations…

  8. Interactive Biology[TM] Multimedia Courseware Series. [CD-ROM].

    ERIC Educational Resources Information Center

    1999

    Interactive Biology Multimedia Courseware is an on-going project, with new titles continually under development. Currently, Interactive Biology includes 38 biological titles on CD-ROM for Macintosh and IBM-compatible systems. Each title deals with a specific biological subject and provides in-depth, comprehensive course material for the 9th grade…

  9. AFTOMS Technology Issues and Alternatives Report

    DTIC Science & Technology

    1989-12-01

    color , resolu- power requirements, physi- tion; memory , processor speed; cal and weather rugged- IAN interfaces, etc,) f,: these ness. display...Telephone and Telegraph 3 CD-I Compact Disk - Interactive CD-ROM Compact Disk-Read Only Memory CGM Computer Graphics Metafile CNWDI Critical Nuclear...Database Management System RFP Request For Proposal 3 RFS Remote File System ROM Read Only Memory 3 S SA-ALC San Antonio Air Logistics Center 3 SAC

  10. Lake Mohave Geophysical Survey 2002: GIS Data Release

    USGS Publications Warehouse

    Cross, VeeAnn A.; Foster, David S.; Twichell, David C.

    2005-01-01

    This CD-ROM contains sidescan-sonar imagery, sub-bottom reflection profiles, and an interpretive map derived from these data. These data were collected in Lake Mohave, a reservoir behind the Davis Dam and below the Hoover Dam on the Colorado River. These data are veiwable within an Environmental system Research Institute, Inc. (ESRI) Geographic Information system (GIS) ArcView 3.2 project file stored on this CD-ROM

  11. Development and Utilization of the Regional Oceanic Modeling System (ROMS)

    DTIC Science & Technology

    2008-09-30

    the Peru/ Chile Current system (PCS). Emphasis is put on the PCS due to its direct connection with the equatorial region; this makes it a good...nearshore wind drop-off that occurs in reality. Numerical simulations of the Peru/ Chile (PCS) and the California (CCS) upwelling systems are being... Chile and the USWC 4. More subtle effects of the wind/SST coupling on the mesoscale eddy activity are now investigated. RESULTS Since funds for

  12. Predicting drifter trajectories and particle dispersion in the Caribbean using a high resolution coastal ocean forecasting system

    NASA Astrophysics Data System (ADS)

    Solano, M.

    2016-02-01

    The present study discusses the accuracy of a high-resolution ocean forecasting system in predicting floating drifter trajectories and the uncertainty of modeled particle dispersion in coastal areas. Trajectories were calculated using an offline particle-tracking algorithm coupled to the operational model developed for the region of Puerto Rico by CariCOOS. Both, a simple advection algorithm as well as the Larval TRANSport (LTRANS) model, a more sophisticated offline particle-tracking application, were coupled to the ocean model. Numerical results are compared with 12 floating drifters deployed in the near-shore of Puerto Rico during February and March 2015, and tracked for several days using Global Positioning Systems mounted on the drifters. In addition the trajectories have also been calculated with the AmSeas Navy Coastal Ocean Model (NCOM). The operational model is based on the Regional Ocean Modeling System (ROMS) with a uniform horizontal resolution of 1/100 degrees (1.1km). Initial, surface and open boundary conditions are taken from NCOM, except for wind stress, which is computed using winds from the National Digital Forecasting Database. Probabilistic maps were created to quantify the uncertainty of particle trajectories at different locations. Results show that the forecasted trajectories are location dependent, with tidally active regions having the largest error. The predicted trajectories by both the ROMS and NCOM models show good agreement on average, however both perform differently at particular locations. The effect of wind stress on the drifter trajectories is investigated to account for wind slippage. Furthermore, a real case scenario is presented where simulated trajectories show good agreement when compared to the actual drifter trajectories.

  13. Novel parametric reduced order model for aeroengine blade dynamics

    NASA Astrophysics Data System (ADS)

    Yuan, Jie; Allegri, Giuliano; Scarpa, Fabrizio; Rajasekaran, Ramesh; Patsias, Sophoclis

    2015-10-01

    The work introduces a novel reduced order model (ROM) technique to describe the dynamic behavior of turbofan aeroengine blades. We introduce an equivalent 3D frame model to describe the coupled flexural/torsional mode shapes, with their relevant natural frequencies and associated modal masses. The frame configurations are identified through a structural identification approach based on a simulated annealing algorithm with stochastic tunneling. The cost functions are constituted by linear combinations of relative errors associated to the resonance frequencies, the individual modal assurance criteria (MAC), and on either overall static or modal masses. When static masses are considered the optimized 3D frame can represent the blade dynamic behavior with an 8% error on the MAC, a 1% error on the associated modal frequencies and a 1% error on the overall static mass. When using modal masses in the cost function the performance of the ROM is similar, but the overall error increases to 7%. The approach proposed in this paper is considerably more accurate than state-of-the-art blade ROMs based on traditional Timoshenko beams, and provides excellent accuracy at reduced computational time when compared against high fidelity FE models. A sensitivity analysis shows that the proposed model can adequately predict the global trends of the variations of the natural frequencies when lumped masses are used for mistuning analysis. The proposed ROM also follows extremely closely the sensitivity of the high fidelity finite element models when the material parameters are used in the sensitivity.

  14. Efficient Bayesian parameter estimation with implicit sampling and surrogate modeling for a vadose zone hydrological problem

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Pau, G. S. H.; Finsterle, S.

    2015-12-01

    Parameter inversion involves inferring the model parameter values based on sparse observations of some observables. To infer the posterior probability distributions of the parameters, Markov chain Monte Carlo (MCMC) methods are typically used. However, the large number of forward simulations needed and limited computational resources limit the complexity of the hydrological model we can use in these methods. In view of this, we studied the implicit sampling (IS) method, an efficient importance sampling technique that generates samples in the high-probability region of the posterior distribution and thus reduces the number of forward simulations that we need to run. For a pilot-point inversion of a heterogeneous permeability field based on a synthetic ponded infiltration experiment simu­lated with TOUGH2 (a subsurface modeling code), we showed that IS with linear map provides an accurate Bayesian description of the parameterized permeability field at the pilot points with just approximately 500 forward simulations. We further studied the use of surrogate models to improve the computational efficiency of parameter inversion. We implemented two reduced-order models (ROMs) for the TOUGH2 forward model. One is based on polynomial chaos expansion (PCE), of which the coefficients are obtained using the sparse Bayesian learning technique to mitigate the "curse of dimensionality" of the PCE terms. The other model is Gaussian process regression (GPR) for which different covariance, likelihood and inference models are considered. Preliminary results indicate that ROMs constructed based on the prior parameter space perform poorly. It is thus impractical to replace this hydrological model by a ROM directly in a MCMC method. However, the IS method can work with a ROM constructed for parameters in the close vicinity of the maximum a posteriori probability (MAP) estimate. We will discuss the accuracy and computational efficiency of using ROMs in the implicit sampling procedure for the hydrological problem considered. This work was supported, in part, by the U.S. Dept. of Energy under Contract No. DE-AC02-05CH11231

  15. CDROM User Interface Evaluation: The Appropriateness of GUIs.

    ERIC Educational Resources Information Center

    Bosch, Victoria Manglano; Hancock-Beaulieu, Micheline

    1995-01-01

    Assesses the appropriateness of GUIs (graphical user interfaces), more specifically Windows-based interfaces for CD-ROM. An evaluation model is described that was developed to carry out an expert evaluation of the interfaces of seven CD-ROM products. Results are discussed in light of HCI (human-computer interaction) usability criteria and design…

  16. The ROM Kit: A Fresh Look at Teaching Roman History.

    ERIC Educational Resources Information Center

    Shore, Paul J.

    1982-01-01

    Describes materials in a kit assembled by the Royal Ontario Museum (ROM) that can be used to revitalize the teaching of Roman history and as a model for teaching about ancient history in general. The author also suggests a new approach, concepts, and topics that should be used in teaching Roman history. (AM)

  17. Biogeochemical responses to meso- and submesoscale oceanic variability in the Kuroshio region

    NASA Astrophysics Data System (ADS)

    Suzue, Y.; Uchiyama, Y.; Yamazaki, H.

    2016-02-01

    Influences of the Kuroshio and associated meso- and submesoscale variability due to frontally- and topographically-induced eddies on biogeochemical processes in the Kuroshio region off Japan are examined with a synoptic downscaling ocean modeling using the UCLA version of ROMS (Shchepetkin and McWilliams, 2005; 2008) coupled with an NPZD (nutrient, phyto/zooplanktons and detritus) nitrogen-based biogeochemical model (e.g., Fasham et al., 1990). The hydrodynamic model is initialized and forced by the JCOPE2 assimilative oceanic reanalysis (Miyazawa et al., 2009) with a horizontal grid resolution of 1/12o (dx ≈ 10 km) to convey the basin-scale information including the transient Kuroshio path though the parent ROMS-L1 model (dx = 3 km) and the child ROMS-L2 model (dx = 1 km) successively with the one-way offline nesting technique (Mason et al., 2011). The JMA GPV-MSM assimilative atmospheric reanalysis (dx = 6 km) is used to force both the ROMS models, while the NPZD model is configured according to Gruber et al. (2006). The model result is extensively compared with satellite (e.g., AVISO, MODIS/Aqua Chl.a) and in-situ data (e.g., the JMA's ship measurement) to confirm good agreement. The submesoscale eddy-resolving L2 output exhibits that intermediate water containing abundant nutrients occasionally surfaces by localized upwelling associated with cyclonic eddies, and that high Chl.a concentration appears around the Kuroshio Front. Furthermore, it is found that meso- and submesoscale eddies developed between the Kuroshio and the coastline also influence on the nearshore biogeochemical productivity.

  18. Modelling the upwelling offthe east Hainan Island coast in summer 2010

    NASA Astrophysics Data System (ADS)

    Bai, Peng; Gu, Yanzhen; Li, Peiliang; Wu, Kejian

    2016-11-01

    A synoptic-scale upwelling event that developed offthe east coast of the Hainan Island (EHIU) in the summer of 2010 is defined well via processing the Moderate Resolution Imaging Spectroradiometer (MODIS) sea surface temperature (SST) data. The Regional Ocean Modeling System (ROMS) with high spatial resolution has been used to investigate this upwelling event. By comparing the ROMS results against tide station data, Argo float profiles and MODIS SST, it is confirmed that the ROMS reproduces the EHIU well. The cooler-water core (CWC) distinguished by waters < 27.5°C in the EHIU, which occurred in the east Qiongzhou Strait mouth area and was bounded by a high temperature gradient, was the focus of this paper. Vertical structure of the CWC suggests that interaction between the westward flow and the bathymetry slope played a significant role in the formation of CWC. Numerical experiments indicated that the westward flow in the Qiongzhou Strait was the result of tidal rectification over variable topography (Shi et al., 2002), thus tides played a critical role on the development of the CWC. The negative wind stress curl that dominated the east Qiongzhou Strait mouth area suppressed the intensity of the CWC by 0.2-0.4°C. Further, nonlinear interaction between tidal currents and wind stress enhanced vertical mixing greatly, which would benefit the development of the CWC.

  19. A Community Terrain-Following Ocean Modeling System (ROMS/TOMS)

    DTIC Science & Technology

    2012-09-30

    next user workshop will be held in Rio de Janeiro , Brazil, October 22-24, 2012. A special fourth day (October 25) has been added to focus modern...grid_extract.m is used to extract the Delaware Bay refinement grid (58 x 142) and Delaware River composite grid (42 x 55). Similarly, grid_extract.m is

  20. Data base management system and display software for the National Geophysical Data Center geomagnetic CD-ROM's

    NASA Technical Reports Server (NTRS)

    Papitashvili, N. E.; Papitashvili, V. O.; Allen, J. H.; Morris, L. D.

    1995-01-01

    The National Geophysical Data Center has the largest collection of geomagnetic data from the worldwide network of magnetic observatories. The data base management system and retrieval/display software have been developed for the archived geomagnetic data (annual means, monthly, daily, hourly, and 1-minute values) and placed on the center's CD-ROM's to provide users with 'user-oriented' and 'user-friendly' support. This system is described in this paper with a brief outline of provided options.

  1. Pain intensity attenuates movement control of the lumbar spine in low back pain.

    PubMed

    Bauer, C M; Rast, F M; Ernst, M J; Oetiker, S; Meichtry, A; Kool, J; Rissanen, S M; Suni, J H; Kankaanpää, M

    2015-12-01

    Pain intensity attenuates muscular activity, proprioception, and tactile acuity, with consequent changes of joint kinematics. People suffering from low back pain (LBP) frequently show movement control impairments of the lumbar spine in sagittal plane. This cross-sectional, observational study investigated if the intensity of LBP attenuates lumbar movement control. The hypothesis was that lumbar movement control becomes more limited with increased pain intensity. The effect of LBP intensity, measured with a numeric rating scale (NRS), on lumbar movement control was tested using three movement control tests. The lumbar range of motion (ROM), the ratio of lumbar and hip ROM as indicators of direction specific movement control, and the recurrence and determinism of repetitive lumbar movement patterns were assessed in ninety-four persons suffering from LBP of different intensity and measured with an inertial measurement unit system. Generalized linear models were fitted for each outcome. Lumbar ROM (+ 0.03°, p = 0.24) and ratio of lumbar and hip ROM (0.01, p = 0.84) were unaffected by LBP intensity. Each one point increase on the NRS resulted in a decrease of recurrence and determinism of lumbar movement patterns (-3.11 to -0.06, p ⩽ 0.05). Our results indicate changes in movement control in people suffering from LBP. Whether decreased recurrence and determinism of lumbar movement patterns are intensifiers of LBP intensity or a consequence thereof should be addressed in a future prospective study. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. A balanced Kalman filter ocean data assimilation system with application to the South Australian Sea

    NASA Astrophysics Data System (ADS)

    Li, Yi; Toumi, Ralf

    2017-08-01

    In this paper, an Ensemble Kalman Filter (EnKF) based regional ocean data assimilation system has been developed and applied to the South Australian Sea. This system consists of the data assimilation algorithm provided by the NCAR Data Assimilation Research Testbed (DART) and the Regional Ocean Modelling System (ROMS). We describe the first implementation of the physical balance operator (temperature-salinity, hydrostatic and geostrophic balance) to DART, to reduce the spurious waves which may be introduced during the data assimilation process. The effect of the balance operator is validated in both an idealised shallow water model and the ROMS model real case study. In the shallow water model, the geostrophic balance operator eliminates spurious ageostrophic waves and produces a better sea surface height (SSH) and velocity analysis and forecast. Its impact increases as the sea surface height and wind stress increase. In the real case, satellite-observed sea surface temperature (SST) and SSH are assimilated in the South Australian Sea with 50 ensembles using the Ensemble Adjustment Kalman Filter (EAKF). Assimilating SSH and SST enhances the estimation of SSH and SST in the entire domain, respectively. Assimilation with the balance operator produces a more realistic simulation of surface currents and subsurface temperature profile. The best improvement is obtained when only SSH is assimilated with the balance operator. A case study with a storm suggests that the benefit of the balance operator is of particular importance under high wind stress conditions. Implementing the balance operator could be a general benefit to ocean data assimilation systems.

  3. Collaborative Project: Understanding Climate Model Biases in Tropical Atlantic and Their Impact on Simulations of Extreme Climate Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Ping

    Recent studies have revealed that among all the tropical oceans, the tropical Atlantic has experienced the most pronounced warming trend over the 20th century. Many extreme climate events affecting the U.S., such as hurricanes, severe precipitation and drought events, are influenced by conditions in the Gulf of Mexico and the Atlantic Ocean. It is therefore imperative to have accurate simulations of the climatic mean and variability in the Atlantic region to be able to make credible projections of future climate change affecting the U.S. and other countries adjoining the Atlantic Ocean. Unfortunately, almost all global climate models exhibit large biasesmore » in their simulations of tropical Atlantic climate. The atmospheric convection simulation errors in the Amazon region and the associated errors in the trade wind simulations are hypothesized to be a leading cause of the tropical Atlantic biases in climate models. As global climate models have resolutions that are too coarse to resolve some of the atmospheric and oceanic processes responsible for the model biases, we propose to use a high-resolution coupled regional climate model (CRCM) framework to address the tropical bias issue. We propose to combine the expertise in tropical coupled atmosphere-ocean modeling at Texas A&M University (TAMU) and the coupled land-atmosphere modeling expertise at Pacific Northwest National Laboratory (PNNL) to develop a comprehensive CRCM for the Atlantic sector within a general and flexible modeling framework. The atmospheric component of the CRCM will be the NCAR WRF model and the oceanic component will be the Rutgers/UCLA ROMS. For the land component, we will use CLM modified at PNNL to include more detailed representations of vegetation and soil hydrology processes. The combined TAMU-PNNL CRCM model will be used to simulate the Atlantic climate, and the associated land-atmosphere-ocean interactions at a horizontal resolution of 9 km or finer. A particular focus of the model development effort will be to optimize the performance of WRF and ROMS over several thousand of cores by focusing on both the parallel communication libraries and the I/O interfaces, in order to achieve the sustained throughput needed to perform simulations on such fine resolution grids. The CRCM model will be developed within the framework of the Coupler (CPL7) software that is part of the NCAR Community Earth System Model (CESM). Through efforts at PNNL and within the community, WRF and CLM have already been coupled via CPL7. Using the flux coupler approach for the whole CRCM model will allow us to flexibly couple WRF, ROMS, and CLM with each model running on its own grid at different resolutions. In addition, this framework will allow us to easily port parameterizations between CESM and the CRCM, and potentially allow partial coupling between the CESM and the CRCM. TAMU and PNNL will contribute cooperatively to this research endeavor. The TAMU team led by Chang and Saravanan has considerable experience in studying atmosphere-ocean interactions within tropical Atlantic sector and will focus on modeling issues that relate to coupling WRF and ROMS. The PNNL team led by Leung has extensive expertise in atmosphere-land interaction and will be responsible for improving the land surface parameterization. Both teams will jointly work on integrating WRF-ROMS and WRF-CLM to couple WRF, ROMS, and CLM through CPL7. Montuoro of the TAMU Supercomputing Center will be responsible for improving the MPI and Parallel IO interfaces of the CRCM. Both teams will contribute to the design and execution of the proposed numerical experiments and jointly perform analysis of the numerical experiments.« less

  4. Numerical Investigation of the Middle Atlantic Bight Shelfbreak Frontal Circulation Using a High-Resolution Ocean Hindcast Model

    DTIC Science & Technology

    2010-05-01

    circulation from December 2003 to June 2008 . The model is driven by tidal harmonics, realistic atmospheric forcing, and dynamically consistent initial and open...important element of the regional circulation (He and Wilkin 2006). We applied the method of Mellor and Yamada (1982) to compute vertical turbulent...shelfbreak ROMS hindcast ran continuously from December 2003 through January 2008 . Initial conditions were taken from the MABGOM ROMS simulation on 1

  5. Modeling Circulation along the Vietnamese Coast Influenced by Monsoon Variability in Meteorology, River Discharge and Interactions with the Vietnamese East Sea

    DTIC Science & Technology

    2013-09-30

    productivity. Advanced variational methods for the assimilation of satellite and in situ observations to achieve improved state estimation and subsequent...time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection...South China Sea (SCS) using the Regional Ocean Modeling System (ROMS) with Incremental Strong Constraint 4-Dimensional Variational (IS4DVAR) data

  6. Scaling laws and reduced-order models for mixing and reactive-transport in heterogeneous anisotropic porous media

    NASA Astrophysics Data System (ADS)

    Mudunuru, M. K.; Karra, S.; Nakshatrala, K. B.

    2016-12-01

    Fundamental to enhancement and control of the macroscopic spreading, mixing, and dilution of solute plumes in porous media structures is the topology of flow field and underlying heterogeneity and anisotropy contrast of porous media. Traditionally, in literature, the main focus was limited to the shearing effects of flow field (i.e., flow has zero helical density, meaning that flow is always perpendicular to vorticity vector) on scalar mixing [2]. However, the combined effect of anisotropy of the porous media and the helical structure (or chaotic nature) of the flow field on the species reactive-transport and mixing has been rarely studied. Recently, it has been experimentally shown that there is an irrefutable evidence that chaotic advection and helical flows are inherent in porous media flows [1,2]. In this poster presentation, we present a non-intrusive physics-based model-order reduction framework to quantify the effects of species mixing in-terms of reduced-order models (ROMs) and scaling laws. The ROM framework is constructed based on the recent advancements in non-negative formulations for reactive-transport in heterogeneous anisotropic porous media [3] and non-intrusive ROM methods [4]. The objective is to generate computationally efficient and accurate ROMs for species mixing for different values of input data and reactive-transport model parameters. This is achieved by using multiple ROMs, which is a way to determine the robustness of the proposed framework. Sensitivity analysis is performed to identify the important parameters. Representative numerical examples from reactive-transport are presented to illustrate the importance of the proposed ROMs to accurately describe mixing process in porous media. [1] Lester, Metcalfe, and Trefry, "Is chaotic advection inherent to porous media flow?," PRL, 2013. [2] Ye, Chiogna, Cirpka, Grathwohl, and Rolle, "Experimental evidence of helical flow in porous media," PRL, 2015. [3] Mudunuru, and Nakshatrala, "On enforcing maximum principles and achieving element-wise species balance for advection-diffusion-reaction equations under the finite element method," JCP, 2016. [4] Quarteroni, Manzoni, and Negri. "Reduced Basis Methods for Partial Differential Equations: An Introduction," Springer, 2016.

  7. EOSDIS Terra Data Sampler #1: Western US Wildfires 2000. 1.1

    NASA Technical Reports Server (NTRS)

    Perkins, Dorothy C. (Technical Monitor)

    2000-01-01

    This CD-ROM contains sample data in HDF-EOS format from the instruments on board the Earth Observing System (EOS) Terra satellite: (1) Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER); (2) Clouds and the Earth's Radiant Energy System (CERES); (3) Multi-angle Imaging Spectroradiometer (MISR); and (4) Moderate Resolution Imaging Spectroradiometer (MODIS). Data from the Measurements of Pollution in the Troposphere (MOPITT) instrument were not available for distribution (as of October 17, 2000). The remotely sensed, coincident data for the Western US wildfires were acquired August 30, 2000. This CD-ROM provides information about the Terra mission, instruments, data, and viewing tools. It also provides the Collage tool for viewing data, and links to Web sites containing other digital data processing software. Full granules of the data on this CD-ROM and other EOS Data and Information System (EOSDIS) data products are available from the NASA Distributed Active Archive Centers (DAACs).

  8. Camera-tracking gaming control device for evaluation of active wrist flexion and extension.

    PubMed

    Shefer Eini, Dalit; Ratzon, Navah Z; Rizzo, Albert A; Yeh, Shih-Ching; Lange, Belinda; Yaffe, Batia; Daich, Alexander; Weiss, Patrice L; Kizony, Rachel

    Cross sectional. Measuring wrist range of motion (ROM) is an essential procedure in hand therapy clinics. To test the reliability and validity of a dynamic ROM assessment, the Camera Wrist Tracker (CWT). Wrist flexion and extension ROM of 15 patients with distal radius fractures and 15 matched controls were assessed with the CWT and with a universal goniometer. One-way model intraclass correlation coefficient analysis indicated high test-retest reliability for extension (ICC = 0.92) and moderate reliability for flexion (ICC = 0.49). Standard error for extension was 2.45° and for flexion was 4.07°. Repeated-measures analysis revealed a significant main effect for group; ROM was greater in the control group (F[1, 28] = 47.35; P < .001). The concurrent validity of the CWT was partially supported. The results indicate that the CWT may provide highly reliable scores for dynamic wrist extension ROM, and moderately reliable scores for flexion, in people recovering from a distal radius fracture. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  9. Pan-American Health Organization CD-ROM Pilot Project.

    ERIC Educational Resources Information Center

    Brito, Claudio J.

    1987-01-01

    Examines the difficulties faced by the implementors of information dissemination systems in developing nations and explores the possible use of optical data disk technologies to overcome them. A pilot project of the Pan American Health Organization for the production of a CD-ROM containing bibliographic references on public health is described.…

  10. The Distribution of Information: The Role for Online Public Access Catalogs.

    ERIC Educational Resources Information Center

    Matthews, Joseph R.

    1994-01-01

    Describes the Online Public Access Catalog (OPAC) and the inclusion of abstracting and indexing industry databases in OPACs. Topics addressed include the implications of including abstracting and indexing tape and CD-ROM products in OPACs; the need for standards allowing library systems to communicate with dissimilar CD-ROM products; and computer,…

  11. Reduced-Order Modeling for Flutter/LCO Using Recurrent Artificial Neural Network

    NASA Technical Reports Server (NTRS)

    Yao, Weigang; Liou, Meng-Sing

    2012-01-01

    The present study demonstrates the efficacy of a recurrent artificial neural network to provide a high fidelity time-dependent nonlinear reduced-order model (ROM) for flutter/limit-cycle oscillation (LCO) modeling. An artificial neural network is a relatively straightforward nonlinear method for modeling an input-output relationship from a set of known data, for which we use the radial basis function (RBF) with its parameters determined through a training process. The resulting RBF neural network, however, is only static and is not yet adequate for an application to problems of dynamic nature. The recurrent neural network method [1] is applied to construct a reduced order model resulting from a series of high-fidelity time-dependent data of aero-elastic simulations. Once the RBF neural network ROM is constructed properly, an accurate approximate solution can be obtained at a fraction of the cost of a full-order computation. The method derived during the study has been validated for predicting nonlinear aerodynamic forces in transonic flow and is capable of accurate flutter/LCO simulations. The obtained results indicate that the present recurrent RBF neural network is accurate and efficient for nonlinear aero-elastic system analysis

  12. An object-oriented, technology-adaptive information model

    NASA Technical Reports Server (NTRS)

    Anyiwo, Joshua C.

    1995-01-01

    The primary objective was to develop a computer information system for effectively presenting NASA's technologies to American industries, for appropriate commercialization. To this end a comprehensive information management model, applicable to a wide variety of situations, and immune to computer software/hardware technological gyrations, was developed. The model consists of four main elements: a DATA_STORE, a data PRODUCER/UPDATER_CLIENT and a data PRESENTATION_CLIENT, anchored to a central object-oriented SERVER engine. This server engine facilitates exchanges among the other model elements and safeguards the integrity of the DATA_STORE element. It is designed to support new technologies, as they become available, such as Object Linking and Embedding (OLE), on-demand audio-video data streaming with compression (such as is required for video conferencing), Worldwide Web (WWW) and other information services and browsing, fax-back data requests, presentation of information on CD-ROM, and regular in-house database management, regardless of the data model in place. The four components of this information model interact through a system of intelligent message agents which are customized to specific information exchange needs. This model is at the leading edge of modern information management models. It is independent of technological changes and can be implemented in a variety of ways to meet the specific needs of any communications situation. This summer a partial implementation of the model has been achieved. The structure of the DATA_STORE has been fully specified and successfully tested using Microsoft's FoxPro 2.6 database management system. Data PRODUCER/UPDATER and PRESENTATION architectures have been developed and also successfully implemented in FoxPro; and work has started on a full implementation of the SERVER engine. The model has also been successfully applied to a CD-ROM presentation of NASA's technologies in support of Langley Research Center's TAG efforts.

  13. Planning and Preparation for CD-ROM Implementation: The Citadel Library.

    ERIC Educational Resources Information Center

    Maynard, J. Edmund

    Management guidelines for library planning and a strategic planning program profile based on the literature were used in the planning process for implementing access to databases on CD-ROM at the Daniel Library of the Citadel, Military College of South Carolina. According to this model, the planning process would consist of five stages: (1)…

  14. Modeling impairment: using the disablement process as a framework to evaluate determinants of hip and knee flexion.

    PubMed

    Lichtenstein, M J; Dhanda, R; Cornell, J E; Escalante, A; Hazuda, H P

    2000-06-01

    Elders often present to health care providers with multiple inter-related conditions that determine an individual's ability to function. The disablement process provides a generalized sociomedical framework for investigating the complex pathways from chronic disease to disability. At each stage of the main pathway, associations may exist among primary physical factors and modifying variables that ultimately have downstream effects on the progression toward disability. The purpose of the present analysis is to examine the inter-relationships between a cohesive set of variables primarily at the level of impairment that may affect hip and knee flexion range of motion (ROM). The San Antonio Longitudinal Study of Aging enrolled 833 community dwelling Mexican (MA) and European American (EA) elders aged 64-78 years between 1992 and 1996. Of these, 647 had complete data from both a home-based and performance-based battery of assessments for these analyses. Concerning impairments, hip ROM was measured using an inclinometer, and knee ROM using a goniometer. Pain location and intensity were assessed using the McGill Pain Questionnaire. Peripheral vascular disease was assessed using doppler brachial and ankle systolic blood pressures. Ankle and knee reflexes, and vibratory sensation were assessed by a standardized neurological examination. As to diseases, diabetes was assessed using a combination of blood glucose levels and self-report, and arthritis by self-report. Concerning modifying variables, height and weight were directly measured and used to calculate BMI. Activity level was assessed with the Minnesota Leisure Time Questionnaire. Analgesic use was assessed by direct observation of medications taken within the past two weeks. We used structural equation modeling to test associations between the variables that were specified a priori. These analyses demonstrate the central role of BMI as a determinant of hip and knee flexion ROM. For an increase in level of BMI, the coefficients [SEM] for changes in levels of hip and knee ROM were -0.38 [0.05] and -0.26 [0.05], respectively. A higher BMI resulted in lower hip and knee ROM. BMI was also directly associated with prevalent diabetes (0.10 [0.05]) and arthritis (0.17 [0.05]). However, after adjustment for BMI, diabetes and arthritis did not have direct independent associations with either hip or knee ROM. BMI was also indirectly associated with knee, but not hip, ROM through paths including lower-leg pain, pain intensity, and neurosensory impairments. Diabetes had an indirect association with hip, but not knee ROM, through a path including peripheral vascular disease. In conclusion, BMI is a primary direct determinant of hip and knee ROM. The paths by which diabetes and arthritis lead to physical disability may be mediated, in part, at the level of impairment by BMI's association with joint range of motion. Interventions designed to decrease the impact of diabetes and arthritis on disability should track changes in BMI and joint ROM to measure the paths that account for the intervention's success. The observed associations suggest that interventions targeted to decrease BMI itself may lead to improved function in part through improved joint ROM.

  15. Intensification of upwelling along Oman coast in a warming scenario

    NASA Astrophysics Data System (ADS)

    Praveen, V.; Ajayamohan, R. S.; Valsala, V.; Sandeep, S.

    2016-07-01

    The oceanic impact of poleward shift in monsoon low-level jet (MLLJ) is examined using a Regional Ocean Modeling System (ROMS). Two sets of downscaling experiments were conducted using ROMS with boundary and initial conditions from six CMIP5 models. While outputs from the historical run (1981-2000) acts as forcing for the first, the second uses RCP8.5 (2080-2099). By comparing the outputs, it is found that Oman coast will experience an increase in upwelling in tune with MLLJ shift. Consistent with the changes in upwelling and zonal Ekman transport, temperature, salinity, and productivity show significant changes near the Oman coast. The changes in MLLJ causes the coastal wind to angle against the Oman coast in such a fashion that the net upwelling increases in the next century and so does the marine productivity. This study contrasts the general view of weakening of upwelling along the Arabian coasts due to the weakening of monsoon winds.

  16. Shared Decision Making in mental health care using Routine Outcome Monitoring as a source of information: a cluster randomised controlled trial.

    PubMed

    Metz, Margot J; Franx, Gerdien C; Veerbeek, Marjolein A; de Beurs, Edwin; van der Feltz-Cornelis, Christina M; Beekman, Aartjan T F

    2015-12-15

    Shared Decision Making (SDM) is a way to empower patients when decisions are made about treatment. In order to be effective agents in this process, patients need access to information of good quality. Routine Outcome Monitoring (ROM) may provide such information and therefore may be a key element in SDM. This trial tests the effectiveness of SDM using ROM, primarily aiming to diminish decisional conflict of the patient while making decisions about treatment. The degree of decisional conflict, the primary outcome of this study, encompasses personal certainty about choosing an appropriate treatment, information about options, clarification of patient values, support from others and patients experience of an effective decision making process. Secondary outcomes of the study focus on the working alliance between patient and clinician, adherence to treatment, and clinical outcome and quality of life. This article presents the study protocol of a multi-centre two-arm cluster randomised controlled trial (RCT). The research is conducted in Dutch specialised mental health care teams participating in the ROM Quality Improvement Collaborative (QIC), which aims to implement ROM in daily clinical practice. In the intervention teams, ROM is used as a source of information during the SDM process between the patient and clinician. Control teams receive no specific SDM or ROM instructions and apply decision making as usual. Randomisation is conducted at the level of the participating teams within the mental health organisations. A total of 12 teams from 4 organisations and 364 patients participate in the study. Prior to data collection, the intervention teams are trained to use ROM during the SDM process. Data collection will be at baseline, and at 3 and 6 months after inclusion of the patient. Control teams will implement the SDM and ROM model after completion of the study. This study will provide useful information about the effectiveness of ROM within a SDM framework. Furthermore, with practical guidelines this study may contribute to the implementation of SDM using ROM in mental health care. Reporting of the results is expected from December 2016 onwards. Dutch trial register: TC5262. Trial registration date: 24th of June 2015.

  17. Upper oceanic response to tropical cyclone Phailin in the Bay of Bengal using a coupled atmosphere-ocean model

    NASA Astrophysics Data System (ADS)

    Prakash, Kumar Ravi; Pant, Vimlesh

    2017-01-01

    A numerical simulation of very severe cyclonic storm `Phailin', which originated in southeastern Bay of Bengal (BoB) and propagated northwestward during 10-15 October 2013, was carried out using a coupled atmosphere-ocean model. A Model Coupling Toolkit (MCT) was used to make exchanges of fluxes consistent between the atmospheric model `Weather Research and Forecasting' (WRF) and ocean circulation model `Regional Ocean Modelling System' (ROMS) components of the `Coupled Ocean-Atmosphere-Wave-Sediment Transport' (COAWST) modelling system. The track and intensity of tropical cyclone (TC) Phailin simulated by the WRF component of the coupled model agrees well with the best-track estimates reported by the India Meteorological Department (IMD). Ocean model component (ROMS) was configured over the BoB domain; it utilized the wind stress and net surface heat fluxes from the WRF model to investigate upper oceanic response to the passage of TC Phailin. The coupled model shows pronounced sea surface cooling (2-2.5 °C) and an increase in sea surface salinity (SSS) (2-3 psu) after 06 GMT on 12 October 2013 over the northwestern BoB. Signature of this surface cooling was also observed in satellite data and buoy measurements. The oceanic mixed layer heat budget analysis reveals relative roles of different oceanic processes in controlling the mixed layer temperature over the region of observed cooling. The heat budget highlighted major contributions from horizontal advection and vertical entrainment processes in governing the mixed layer cooling (up to -0.1 °C h-1) and, thereby, reduction in sea surface temperature (SST) in the northwestern BoB during 11-12 October 2013. During the post-cyclone period, the net heat flux at surface regained its diurnal variations with a noontime peak that provided a warming tendency up to 0.05 °C h-1 in the mixed layer. Clear signatures of TC-induced upwelling are seen in vertical velocity (about 2.5 × 10-3 m s-1), rise in isotherms and isohalines along 85-88° E longitudes in the northwestern BoB. The study demonstrates that a coupled atmosphere-ocean model (WRF + ROMS) serves as a useful tool to investigate oceanic response to the passage of cyclones.

  18. Exploration of POD-Galerkin Techniques for Developing Reduced Order Models of the Euler Equations

    DTIC Science & Technology

    2015-07-01

    modes [1]. Barone et al [15, 16] proposed to stabilize the reduced system by symmetrizing the higher-order PDE with a preconditioning matrix. Rowley et...advection scalar equation. The ROM is obtained by employing Galerkin’s method to reduce the high-order PDEs to a lower- order ODE system by means of POD...high-order PDEs to a lower-order ODE system by means of POD eigen-bases. For purposes of this study, a linearized version of the Euler equations is

  19. An immediate effect of axial neck rotation training with real time visual feedback using a smartphone inclinometer on improvement in axial neck rotation function.

    PubMed

    Park, Kyue-Nam; Kwon, Oh-Yun; Kim, Si-Hyun; Jeon, In-Cheol

    2017-03-01

    The purpose of this study was to compare the immediate effects of axial neck rotation training (Axi-NRT) with and without real-time visual feedback (VF) using a smartphone inclinometer on the range of motion (ROM) for axial neck rotation and the onset of compensatory neck lateral bending and extension during active neck rotation. Twenty participants with restricted ROM for neck rotation but no neck pain (21.1 ± 1.6 years and 8 males, 12 females) were recruited for Axi-NRT with VF, and twenty age- and gender-matched participants with restricted ROM for neck rotation were recruited for Axi-NRT without VF. Changes in ROM for neck rotation and the onset time of compensatory neck movement during active neck rotation were measured using an electromagnetic tracking system. Axi-NRT with VF was more effective in increasing ROM for neck rotation and decreasing and delaying the onset of compensatory neck movements during active neck rotation compared with Axi-NRT without VF. Repeated Axi-NRT using VF is useful to educate participants in maintaining the axis of the cervical spine and to increase ROM for axial neck rotation with less compensatory neck motion in participants with a restricted range of neck rotations.

  20. Responsiveness to Change of Functional Limitation Reporting: Cross-sectional Study Using the Intermountain ROMS Scale in Outpatient Rehabilitation.

    PubMed

    Brennan, Gerard P; Hunter, Stephen J; Snow, Greg; Minick, Kate I

    2017-12-01

    The Centers for Medicare and Medicaid Services (CMS) require physical therapists document patients' functional limitations. The process is not standardized. 
A systematic approach to determine a patient's functional limitations and responsiveness to change is needed. The purpose of this study is to compare patient-reported outcomes (PROs) responsiveness to change using 7-level severity/complexity modifier scale proposed by Medicare to a derived scale implemented by Intermountain Healthcare's Rehabilitation Outcomes Management System (ROMS). This was a retrospective, observational cohort design. 165,183 PROs prior to July 1, 2013, were compared to 46,334 records from July 1, 2013, to December 31, 2015. Histograms and ribbon plots illustrate distribution and change of patients' scores. ROMS raw score ranges were calculated and compared to CMS' severity/complexity levels based on score percentage. Distribution of the population was compared based on the 2 methods. Sensitivity and specificity were compared for responsiveness to change based on minimal clinically important difference (MCID). Histograms demonstrated few patient scores placed in CMS scale levels at the extremes, whereas the majority of scores placed in 2 middle levels (CJ, CK). ROMS distributed scores more evenly across levels. Ribbon plots illustrated advantage of ROMS' using narrower score ranges. Greater chance for patients to change levels was observed with ROMS when an MCID was achieved. ROMS narrower scale levels resulted in greater sensitivity and good specificity. Geographic representation for the United States was limited. Without patients' global rating of change, a reference standard to gauge validation of improvement could not be provided. ROMS provides a standard approach to identify accurately functional limitation modifier levels and to detect improvement more accurately than a straight across transposition using the CMS scale. © 2017 American Physical Therapy Association

  1. Membrane morphology and topology for fouling control in Reverse Osmosis filtration systems

    NASA Astrophysics Data System (ADS)

    Ling, Bowen; Battiato, Ilenia

    2017-11-01

    Reverse Osmosis Membrane (ROM) filtration systems are widely utilized in waste-water recovery, seawater desalination, landfill water treatment, etc. During filtration, the system performance is dramatically affected by membrane fouling which causes a significant decrease in permeate flux as well as an increase in the energy input required to operate the system. Design and optimization of ROM filtration systems aim at reducing membrane fouling by studying the coupling between membrane structure, local flow field and foulant adsorption patterns. Yet, current studies focus exclusively on oversimplified steady-state models that ignore any dynamic coupling between fluid flow and transport through the membrane. In this work, we develop a customized solver (SUMembraneFoam) under OpenFOAM to solve the transient equations. The simulation results not only predict macroscopic quantities (e.g. permeate flux, pressure drop, etc.) but also show an excellent agreement with the fouling patterns observed in experiments. It is observed that foulant deposition is strongly controlled by the local shear stress on the membrane, and channel morphology or membrane topology can be modified to control the shear stress distribution and reduce fouling. Finally, we identify optimal regimes for design.

  2. Role of the Guanine Nucleotide Exchange Factor Rom2 in Cell Wall Integrity Maintenance of Aspergillus fumigatus

    PubMed Central

    Samantaray, Sweta; Neubauer, Michael; Helmschrott, Christoph

    2013-01-01

    Aspergillus fumigatus is a mold and the causal agent of invasive aspergillosis, a systemic disease with high lethality. Recently, we identified and functionally characterized three stress sensors implicated in the cell wall integrity (CWI) signaling of this pathogen, namely, Wsc1, Wsc3, and MidA. Here, we functionally characterize Rom2, a guanine nucleotide exchange factor with essential function for the cell wall integrity of A. fumigatus. A conditional rom2 mutant has severe growth defects under repressive conditions and incorporates all phenotypes of the three cell wall integrity sensor mutants, e.g., the echinocandin sensitivity of the Δwsc1 mutant and the Congo red, calcofluor white, and heat sensitivity of the ΔmidA mutant. Rom2 interacts with Rho1 and shows a similar intracellular distribution focused at the hyphal tips. Our results place Rom2 between the cell surface stress sensors Wsc1, Wsc3, MidA, and Rho1 and their downstream effector mitogen-activated protein (MAP) kinase module Bck1-Mkk2-MpkA. PMID:23264643

  3. Addition of lateral bending range of motion measurement to standard sagittal measurement to improve diagnosis sensitivity of ligamentous injury in the human lower cervical spine.

    PubMed

    Leahy, P Devin; Puttlitz, Christian M

    2016-01-01

    This study examined the cervical spine range of motion (ROM) resulting from whiplash-type hyperextension and hyperflexion type ligamentous injuries, and sought to improve the accuracy of specific diagnosis of these injuries. The study was accomplished by measurement of ROM throughout axial rotation, lateral bending, and flexion and extension, using a validated finite element model of the cervical spine that was modified to simulate hyperextension and/or hyperflexion injuries. It was found that the kinematic difference between hyperextension and hyperflexion injuries was minimal throughout the combined flexion and extension ROM measurement that is commonly used for clinical diagnosis of cervical ligamentous injury. However, the two injuries demonstrated substantially different ROM under axial rotation and lateral bending. It is recommended that other bending axes beyond flexion and extension are incorporated into clinical diagnosis of cervical ligamentous injury.

  4. Efficient model reduction of parametrized systems by matrix discrete empirical interpolation

    NASA Astrophysics Data System (ADS)

    Negri, Federico; Manzoni, Andrea; Amsallem, David

    2015-12-01

    In this work, we apply a Matrix version of the so-called Discrete Empirical Interpolation (MDEIM) for the efficient reduction of nonaffine parametrized systems arising from the discretization of linear partial differential equations. Dealing with affinely parametrized operators is crucial in order to enhance the online solution of reduced-order models (ROMs). However, in many cases such an affine decomposition is not readily available, and must be recovered through (often) intrusive procedures, such as the empirical interpolation method (EIM) and its discrete variant DEIM. In this paper we show that MDEIM represents a very efficient approach to deal with complex physical and geometrical parametrizations in a non-intrusive, efficient and purely algebraic way. We propose different strategies to combine MDEIM with a state approximation resulting either from a reduced basis greedy approach or Proper Orthogonal Decomposition. A posteriori error estimates accounting for the MDEIM error are also developed in the case of parametrized elliptic and parabolic equations. Finally, the capability of MDEIM to generate accurate and efficient ROMs is demonstrated on the solution of two computationally-intensive classes of problems occurring in engineering contexts, namely PDE-constrained shape optimization and parametrized coupled problems.

  5. Planning the National Agricultural Library's Multimedia CD-ROM "Ornamental Horticulture."

    ERIC Educational Resources Information Center

    Mason, Pamela R.

    1991-01-01

    Discussion of issues involved in planning a multimedia CD-ROM product explains the selection of authoring tools, the design of a user interface, expert systems, text conversion and capture (including scanning and optical character recognition), and problems associated with image files. The use of audio is also discussed, and a 14-item glossary is…

  6. Intra-articular collagenase injection increases range of motion in a rat knee flexion contracture model

    PubMed Central

    Wong, Kayleigh; Trudel, Guy; Laneuville, Odette

    2018-01-01

    Objectives A knee joint contracture, a loss in passive range of motion (ROM), can be caused by prolonged immobility. In a rat knee immobilization flexion contracture model, the posterior capsule was shown to contribute to an irreversible limitation in ROM, and collagen pathways were identified as differentially expressed over the development of a contracture. Collagenases purified from Clostridium histolyticum are currently prescribed to treat Dupuytren’s and Peyronie’s contractures due to their ability to degrade collagen. The potential application of collagenases to target collagen in the posterior capsule was tested in this model. Materials and methods Rats had one hind leg immobilized, developing a knee flexion contracture. After 4 weeks, the immobilization device was removed, and the rats received one 50 µL intra-articular injection of 0.6 mg/mL purified collagenase. Control rats were injected with only the buffer. After 2 weeks of spontaneous remobilization following the injections, ROM was measured with a rat knee arthrometer, and histological sections were immunostained with antibodies against rat collagen types I and III. Results/conclusion Compared with buffer-injected control knees, collagenase-treated knees showed increased ROM in extension by 8.0°±3.8° (p-value <0.05). Immunohistochemical analysis revealed an increase in collagen type III staining (p<0.01) in the posterior capsule of collagenase-treated knees indicating an effect on the extracellular matrix due to the collagenase. Collagen I staining was unchanged (p>0.05). The current study provides experimental evidence for the pharmacological treatment of knee flexion contractures with intra-articular collagenase injection, improving the knee ROM. PMID:29317799

  7. Manufacturing Methods and Technology for Digital Fault Isolation of Hybrid Microelectronic Assemblies.

    DTIC Science & Technology

    1982-03-01

    Aircraft Company ARECAaSOENT CSR Ground Systems Group Task 007 Fullerton, California 92634 Project No. R1023 I$. =OTRS4.IWmOr SP NAnE lAD ABDASE it. REPORT...HMA feed mechanism, multiple type test sockets or adapters, and a localized UUT vessel for functional tests at temperature. The engineering model AP...test excluding (deactivated) microprocessor. * Models UUT and test adapter as a ROM. Independent latches or registers from interconnecting ports to

  8. Simulation of the Pinatubo Impact on the Red Sea Using Coupled Regional Ocean/Atmosphere Modeling System

    NASA Astrophysics Data System (ADS)

    Stenchikov, G. L.; Osipov, S.

    2016-12-01

    This study focuses on the Middle East regional climate response to the Mt. Pinatubo volcanic eruption of 1991. It is motivated by the observed severe winter cooling in the Middle East during the winter of 1991/92. The Red Sea surface temperature dropped by more than 1K and deep water mixing caused coral bleaching for a few years. To better understand the mechanisms of the Middle East climate response and evaluate the effects of radiative cooling and regional meteorological processes on the Red Sea, we employ the Regional Ocean Modeling system (ROMS) fully coupled with the Weather Research and Forecasting (WRF) model. The WRF model parent and nested domains are configured over the Middle East and North Africa (MENA) region and over the Red Sea with 30 and 10 km resolution, respectively. The ROMS model over the Red Sea has 2 km grid spacing. The WRF code was modified to interactively account for the radiative effect of volcanic aerosols. Spectral optical properties of sulfate aerosols are computed using Mie based on the Sato's optical depth. Both atmosphere and ocean models capture the main features of the MENA climate response and correctly reproduce the anomalous winter cooling of 1991/92. We find that the sea surface cooling associated with meteorological effects prevails that caused by the direct radiative forcing of volcanic aerosols. The overturning circulation in the Red Sea strengthens. The salinity distribution and deep water formation are significantly perturbed.

  9. Method for a dummy CD mirror server based on NAS

    NASA Astrophysics Data System (ADS)

    Tang, Muna; Pei, Jing

    2002-09-01

    With the development of computer network, information sharing is becoming the necessity in human life. The rapid development of CD-ROM and CD-ROM driver techniques makes it possible to issue large database online. After comparing many designs of dummy CD mirror database, which are the embodiment of a main product in CD-ROM database now and in near future, we proposed and realized a new PC based scheme. Our system has the following merits, such as, supporting all kinds of CD format; supporting many network protocol; the independence of mirror network server and the main server; low price, super large capacity, without the need of any special hardware. Preliminarily experiments have verified the validity of the proposed scheme. Encouraged by the promising application future, we are now preparing to put it into market. This paper discusses the design and implement of the CD-ROM server detailedly.

  10. Kinematics and Kinetics of Squat and Deadlift Exercises with Varying Stance Widths

    NASA Technical Reports Server (NTRS)

    DeWitt, John K.; Fincke, Renita S.; Logan, Rachel L.

    2011-01-01

    The primary motion of squat and deadlift exercise involves flexion and extension of the hips, knees, and ankles, but each exercise can be performed with variations in stance width. These variations may result in differing kinematics and ground reaction forces (GRF), which may in turn affect joint loading. PURPOSE: The purpose of this investigation was to compare ankle, knee, and hip kinematics and kinetics of normal squat (NS), wide-stance squat (WS), normal deadlift (ND), and sumo deadlift (SD). We hypothesized that hip joint kinematics and work at each joint would differ between exercise variations. METHODS: Six subjects (3 m/3 f; 70.0 plus or minus 13.7 kg; 168 plus or minus 9.9 cm) performed each lift in normal gravity on the ground-based version of the Advanced Resistive Exercise Device (ARED) used on the International Space Station. The ARED provided resistance with a combination vacuum tube/flywheel mechanism designed to replicate the gravitational and inertial forces of free weights. Subjects completed each lift with their 10-repetition maximum load. Kinematic data were collected at 250 Hz by a 12-camera motion-capture system (Smart-D, BTS Bioengineering, Milan, Italy), and GRF data were collected at 1000 Hz with independent force platforms for each leg (Model 9261, Kistler Instruments AG, Winterhur, Switzerland). All data were captured simultaneously on a single workstation. The right leg of a single lift for each motion was analyzed. Modeling software (OpenSim 2.2.0, Simbios, Palo Alto, CA) determined joint kinematics and net positive and negative work at each lower extremity joint. Total work was found as the sum of work across all joints and was normalized by system mass. Effect sizes and their 95% confidence intervals were computed between conditions. RESULTS: Peak GRF were similar for each lift. There were no differences between conditions in hip flexion range of motion (ROM). For hip adduction ROM, there were no differences between the NS, WS, and SD. However, hip adduction ROM was greater during the NS and SD than during the ND. Hip rotation ROM was greater during the WS than during the NS and SD, and was greater during the SD than during the ND. For knee and ankle flexion ROM, the ND, WS, and SD were not different, but ROM was greater during the NS than the ND and greater during the WS than the SD. Total eccentric work was greater during the WS than the SD. Otherwise, there were no differences in eccentric or concentric work between conditions. CONCLUSIONS: Although squat and deadlift exercises consist of similar motions, there are kinematic differences between them that depend on stance width. Total eccentric and concentric work are similar for different lifts, but differing kinematics may require activation of different musculature for each variation. With respect to each condition, in the ND the ROM of each joint tended to be less, and the WS tended to trade knee motion for hip motion. PRACTICAL APPLICATIONS: Knowledge of differences in kinematics and kinetics between different squat and deadlift variations is important for coaches and rehabilitation personnel to understand when prescribing exercise. Our results suggest that each variation of the squat and deadlift should be considered a separate exercise that may induce different long-term training effects.

  11. Flexible growing rods: a pilot study to determine if polymer rod constructs may provide stability to skeletally immature spines

    PubMed Central

    2015-01-01

    Background Surgical treatments for early onset scoliosis (EOS), including growing rod constructs, involve many complications. Some are due to biomechanical factors. A construct that is more flexible than current instrumentation systems may reduce complications. The purpose of this preliminary study was to determine spine range of motion (ROM) after implantation of simulated growing rod constructs with a range of clinically relevant structural properties. The hypothesis was that ROM of spines instrumented with polyetheretherketone (PEEK) rods would be greater than metal rods and lower than noninstrumented controls. Further, adjacent segment motion was expected to be lower with polymer rods compared to conventional systems. Methods Biomechanical tests were conducted on 6 skeletally immature porcine thoracic spines (domestic swine, 35-40 kg). Spines were harvested after death from swine that had been utilized for other studies (IACUC approved) which had not involved the spine. Paired pedicle screws were used as anchors at proximal and distal levels. Specimens were tested under the following conditions: control, then dual rods of PEEK (6.25 mm), titanium (4 mm), and CoCr (5 mm) alloy. Lateral bending (LB) and flexion-extension (FE) moments of ±5 Nm were applied. Vertebral rotations were measured using video. Differences were determined by two-tailed t-tests and Bonferroni correction with four primary comparisons: PEEK vs control and PEEK vs CoCr, in LB and FE (α=0.05/4). Results In LB, ROM of specimens with PEEK rods was lower than control at each instrumented level. ROM was greater for PEEK rods than both Ti and CoCr at every instrumented level. Mean ROM at proximal and distal noninstrumented levels was lower for PEEK than for Ti and CoCr. In FE, mean ROM at proximal and distal noninstrumented levels was lower for PEEK than for metal. Combining treated levels, in LB, ROM for PEEK rods was 35% of control (p<0.0001) and 270% of CoCr rods (p<0.01). In FE, ROM with PEEK was 27% of control (p<0.001) and 180% of CoCr (p<0.01). Conclusions PEEK rods decreased flexibility versus noninstumented controls, and increased flexibility versus metal rods. Smaller increases in ROM at proximal and distal adjacent motion segments occurred with PEEK compared to metal rods, which may help decrease junctional kyphosis. Flexible growing rods may eventually help improve treatment options for young patients with severe deformity. PMID:25810752

  12. Unveiling the "secret" of play in dogs (Canis lupus familiaris): Asymmetry and signals.

    PubMed

    Cordoni, Giada; Nicotra, Velia; Palagi, Elisabetta

    2016-08-01

    Due to their playful propensity, dogs are a good model to test some hypotheses about play dynamics (length, asymmetry, features of players) and communication (play bow [PBOW]; relaxed open-mouth [ROM] display). We video-recorded 203 play sessions between dogs in an off-leash dog park in Palermo, Italy. Contrary to the expectation, play asymmetry (particularly high in this species) did not differ between stranger and familiar dogs, thus suggesting the limited role of play in forming dominance relationships. Asymmetry negatively affected the duration of the session, whereas the increasing number of players was positively linked to the duration of playful interactions. The number of PBOWs exchanged by players may exert a certain influence on the session length as well. PBOWs were performed independently from the kind of play (locomotor vs. contact) the dogs were engaging in. Conversely, ROMs were preferentially emitted during contact play when "face-to-face" interactions were more likely. Body closeness is also required in case opening the mouth has not a signal function but only preludes a bite. However, in the 82% of cases play bites did not follow a ROM, thus suggesting that dogs place ROMs in the appropriate context to optimize signal detectability. In conclusion, 2 tactics may concur in coping with the asymmetry and unpredictability of play sessions in dogs. First, whenever the asymmetry increases dogs shorten the duration of their sessions thus limiting the risk of possible escalation. Second, dogs make use of a good communicative system based on the reciprocal exchange of playful signals. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Foot and hip contributions to high frontal plane knee projection angle in athletes: a classification and regression tree approach.

    PubMed

    Bittencourt, Natalia F N; Ocarino, Juliana M; Mendonça, Luciana D M; Hewett, Timothy E; Fonseca, Sergio T

    2012-12-01

    Cross-sectional. To investigate predictors of increased frontal plane knee projection angle (FPKPA) in athletes. The underlying mechanisms that lead to increased FPKPA are likely multifactorial and depend on how the musculoskeletal system adapts to the possible interactions between its distal and proximal segments. Bivariate and linear analyses traditionally employed to analyze the occurrence of increased FPKPA are not sufficiently robust to capture complex relationships among predictors. The investigation of nonlinear interactions among biomechanical factors is necessary to further our understanding of the interdependence of lower-limb segments and resultant dynamic knee alignment. The FPKPA was assessed in 101 athletes during a single-leg squat and in 72 athletes at the moment of landing from a jump. The investigated predictors were sex, hip abductor isometric torque, passive range of motion (ROM) of hip internal rotation (IR), and shank-forefoot alignment. Classification and regression trees were used to investigate nonlinear interactions among predictors and their influence on the occurrence of increased FPKPA. During single-leg squatting, the occurrence of high FPKPA was predicted by the interaction between hip abductor isometric torque and passive hip IR ROM. At the moment of landing, the shank-forefoot alignment, abductor isometric torque, and passive hip IR ROM were predictors of high FPKPA. In addition, the classification and regression trees established cutoff points that could be used in clinical practice to identify athletes who are at potential risk for excessive FPKPA. The models captured nonlinear interactions between hip abductor isometric torque, passive hip IR ROM, and shank-forefoot alignment.

  14. Gridded Model Information Support System (GMISS) user's guide. Volume 3. Model-concentration data-retrieval subsystem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Gridded Model Information Support System (GMISS) is a data base management system for selected Regional Oxidant Model (ROM) input data and species concentrations produced by gridded photochemical air pollution models. The Model Concentration Data Retrieval Subsystem allows State and local air pollution control agencies to retrieve these hourly data for use in support of their regulatory programs. These hourly data may be used to calculate initial and boundary conditions for the Empirical Kinetics Modeling Approach (EKMA). They may be used for other modeling application needs as well as to support evaluation of regional emission controls strategies. Both temporal andmore » spatial subsets of the data may be retrieved. The document describes how to invoke and execute the Model Concentration Data Retrieval Subsystem using the full screen menus.« less

  15. The Biomechanical Study of Extraforaminal Lumbar Interbody Fusion: A Three-Dimensional Finite-Element Analysis.

    PubMed

    Yang, Mingjie; Sun, Guixin; Guo, Song; Zeng, Cheng; Yan, Meijun; Han, Yingchao; Xia, Dongdong; Zhang, Jingjie; Li, Xinhua; Xiang, Yang; Pan, Jie; Li, Lijun; Tan, Jun

    2017-01-01

    Finite-element method was used to evaluate biomechanics stability of extraforaminal lumbar interbody fusion (ELIF) under different internal fixation. The L3-L5 level finite-element model was established to simulate decompression and internal fixation at L4-L5 segment. The intact finite model was treated in accordance with the different internal fixation. The treatment groups were exerted 400 N load and 6 N·m additional force from motion to calculate the angular displacement of L4-L5. The ROMs were smaller in all internal fixation groups than those in the intact model. Furthermore, the ROMs were smaller in ELIF + UPS group than in TLIF + UPS group under all operating conditions, especially left lateral flexion and right rotation. The ROMs were higher in ELIF + UPS group than in TLIF + BPS group. The ROMs of ELIF + UPS + TLFS group were much smaller than those in ELIF + UPS group, and as compared with TLIF + BPS group, there was no significant difference in the range of experimental loading. The biomechanical stability of ELIF with unilateral pedicle screw fixation is superior to that of TLIF with unilateral pedicle screw fixation but lower than that of TLIF with bilateral pedicle screws fixation. The stability of ELIF with unilateral fixation can be further improved by supplementing a translaminar facet screw.

  16. [Benchmarking and other functions of ROM: back to basics].

    PubMed

    Barendregt, M

    2015-01-01

    Since 2011 outcome data in the Dutch mental health care have been collected on a national scale. This has led to confusion about the position of benchmarking in the system known as routine outcome monitoring (rom). To provide insight into the various objectives and uses of aggregated outcome data. A qualitative review was performed and the findings were analysed. Benchmarking is a strategy for finding best practices and for improving efficacy and it belongs to the domain of quality management. Benchmarking involves comparing outcome data by means of instrumentation and is relatively tolerant with regard to the validity of the data. Although benchmarking is a function of rom, it must be differentiated form other functions from rom. Clinical management, public accountability, research, payment for performance and information for patients are all functions of rom which require different ways of data feedback and which make different demands on the validity of the underlying data. Benchmarking is often wrongly regarded as being simply a synonym for 'comparing institutions'. It is, however, a method which includes many more factors; it can be used to improve quality and has a more flexible approach to the validity of outcome data and is less concerned than other rom functions about funding and the amount of information given to patients. Benchmarking can make good use of currently available outcome data.

  17. Occupational Analysis Products: Operations Management- AFSC 3E6X1 (CD-ROM)

    DTIC Science & Technology

    computer laser optical disc (CD-ROM); 4 3/4 in.; 23.4 MB. SYSTEMS DETAIL NOTE: ABSTRACT: This is a report of an occupational survey of the Operations ... Management (AFSC 3E6X1, OSSN 2560, Feb 04) career ladder, conducted by the Occupational Analysis Flight, AFOMS. The OSR reports the findings of current

  18. Simultaneous Excitation of Multiple-Input Multiple-Output CFD-Based Unsteady Aerodynamic Systems

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.

    2008-01-01

    A significant improvement to the development of CFD-based unsteady aerodynamic reduced-order models (ROMs) is presented. This improvement involves the simultaneous excitation of the structural modes of the CFD-based unsteady aerodynamic system that enables the computation of the unsteady aerodynamic state-space model using a single CFD execution, independent of the number of structural modes. Four different types of inputs are presented that can be used for the simultaneous excitation of the structural modes. Results are presented for a flexible, supersonic semi-span configuration using the CFL3Dv6.4 code.

  19. Simultaneous Excitation of Multiple-Input Multiple-Output CFD-Based Unsteady Aerodynamic Systems

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.

    2007-01-01

    A significant improvement to the development of CFD-based unsteady aerodynamic reduced-order models (ROMs) is presented. This improvement involves the simultaneous excitation of the structural modes of the CFD-based unsteady aerodynamic system that enables the computation of the unsteady aerodynamic state-space model using a single CFD execution, independent of the number of structural modes. Four different types of inputs are presented that can be used for the simultaneous excitation of the structural modes. Results are presented for a flexible, supersonic semi-span configuration using the CFL3Dv6.4 code.

  20. Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

    PubMed

    Jung, Hungu; Yamasaki, Masahiro

    2016-12-08

    Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.

  1. “Wine-Dark Sea” in an Organic Flow Battery: Storing Negative Charge in 2,1,3-Benzothiadiazole Radicals Leads to Improved Cyclability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duan, Wentao; Huang, Jinhua; Kowalski, Jeffrey A.

    Redox-active organic materials (ROMs) have shown great promise for redox flow battery applications but generally encounter limited cycling efficiency and stability at relevant redox material concentrations in nonaqueous systems. Here we report a new heterocyclic organic anolyte molecule, 2,1,3-benzothiadiazole, that has high solubility, a low redox potential, and fast electrochemical kinetics. Coupling it with a benchmark catholyte ROM, the nonaqueous organic flow battery demonstrated significant improvement in cyclable redox material concentrations and cell efficiencies compared to the state-of-the-art nonaqueous systems. Especially, this system produced exceeding cyclability with relatively stable efficiencies and capacities at high ROM concentrations (>0.5 M), which ismore » ascribed to the highly delocalized charge densities in the radical anions of 2,1,3-benzothiadiazole, leading to good chemical stability. As a result, this material development represents significant progress toward promising next-generation energy storage.« less

  2. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Nagatsuka, Takashi

    This paper introduces the CD-ROM-aided products and their utilization in foreign countries, mainly in U.S.A. CD-ROM is being used in various fields recently. Author classified its products into four groups:1. CD-ROM that substitutes for printed matters such as encyclopedias and dictionaries (ex. Grolier's Electronic Encyclopedia), 2. CD-ROM that substitutes for online databases (ex. Disclosure, Medline), 3. CD-ROM that has some functions such as giving orders for books besides information retrieval (ex. Books in Print Plus), 4. CD-ROM that contains literatures including pictures and figures (ex. ADONIS). The future trends of CD-ROM utilization are also suggested.

  3. Integration of numerical modeling and observations for the Gulf of Naples monitoring network

    NASA Astrophysics Data System (ADS)

    Iermano, I.; Uttieri, M.; Zambianchi, E.; Buonocore, B.; Cianelli, D.; Falco, P.; Zambardino, G.

    2012-04-01

    Lethal effects of mineral oils on fragile marine and coastal ecosystems are now well known. Risks and damages caused by a maritime accident can be reduced with the help of better forecasts and efficient monitoring systems. The MED project TOSCA (Tracking Oil Spills and Coastal Awareness Network), which gathers 13 partners from 4 Mediterranean countries, has been designed to help create a better response system to maritime accidents. Through the construction of an observational network, based on state of the art technology (HF radars and drifters), TOSCA provides real-time observations and forecasts of the Mediterranean coastal marine environmental conditions. The system is installed and assessed in five test sites on the coastal areas of oil spill outlets (Eastern Mediterranean) and on high traffic areas (Western Mediterranean). The Gulf of Naples, a small semi-closed basin opening to the Tyrrhenian Sea is one of the five test-sites. It is of particular interest from both the environmental point of view, due to peculiar ecosystem properties in the area, and because it sustains important touristic and commercial activities. Currently the Gulf of Naples monitoring network is represented by five automatic weather stations distributed along the coasts of the Gulf, one weather radar, two tide gauges, one waverider buoy, and moored physical, chemical and bio-optical instrumentation. In addition, a CODAR-SeaSonde HF coastal radar system composed of three antennas is located in Portici, Massa Lubrense and Castellammare. The system provides hourly data of surface currents over the entire Gulf with a 1km spatial resolution. A numerical modeling implementation based on Regional Ocean Modeling System (ROMS) is actually integrated in the Gulf of Naples monitoring network. ROMS is a 3-D, free-surface, hydrostatic, primitive equation, finite difference ocean model. In our configuration, the model has high horizontal resolution (250m), and 30 sigma levels in the vertical. Thanks to the cooperation of the Ocean Physics and Modeling Group and of the Atmospheric Modeling and Weather Forecasting Group of the University of Athens (partner of TOSCA project), the model surface air-sea fluxes are computed from the SKIRON Forecasting System. ROMS model is initialized with the High Resolution Atlantic and Mediterranean Product of Mercator Ocean data set and the same data are used as boundary conditions for the western and southern open boundaries of the domain. Realistic model simulations have been performed in the study area for the summer of 2009, in order to make comparisons with specific episodes and structures identified by HF radar data. Typical circulation regimes have been selected from the mentioned year simulation and different flow structures are recognized, that are expected to have a significant effect on the renewal of the coastal waters. The model allows us to further investigate the spatial characteristics of dynamical structures, their generation process and their role in the flushing of the basin improving the understanding of the dynamics governing the circulation of the basin. Model results show a good agreement with HF radar data collected during the analyzed periods in the Gulf of Naples.

  4. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System.

    PubMed

    Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon

    2016-08-01

    To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  5. The Novice User and CD-ROM Database Services. ERIC Digest.

    ERIC Educational Resources Information Center

    Schamber, Linda

    This digest answers the following questions that beginning or novice users may have about CD-ROM (a compact disk with read-only memory) database services: (1) What is CD-ROM? (2) What databases are available? (3) Is CD-ROM difficult to use? (4) How much does CD-ROM cost? and (5) What is the future of CD-ROM? (15 references) (MES)

  6. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    PubMed

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Age-dependent risk factors for malnutrition in traumatology and orthopedic patients.

    PubMed

    Lambert, Christine; Nüssler, Andreas; Biesalski, Hans Konrad; Freude, Thomas; Bahrs, Christian; Ochs, Gunnar; Flesch, Ingo; Stöckle, Ulrich; Ihle, Christoph

    2017-05-01

    The aim of this study was to investigate the prevalence of risk of malnutrition (RoM) in an orthopedic and traumatology patient cohort with a broad range of ages. In addition to the classical indicators for risk assessment (low body mass index, weight loss, and comorbidity), this study aimed to analyze the effects of lifestyle factors (eating pattern, smoking, physical activity) on RoM. The prospective cohort study included 1053 patients in a level 1 trauma center in Germany. RoM was assessed by Nutritional Risk Screening (NRS) 2002 and for the elderly additionally by Mini Nutritional Assessment (MNA). Age-dependent risk factors identified in univariate statistical analysis were used for multivariate logistic regression models. The prevalence of patients at RoM (NRS ≥3) was 22%. In the three age categories (<50 y, 50-69 y, and ≥70 y), loss of appetite, weight loss, number of comorbidities, drugs and gastrointestinal symptoms significantly increased RoM in univariate statistical analysis. In patients ages ≥70 y, several disease- and lifestyle-related factors (not living at home, less frequent consumption of vegetables and whole meal bread, low physical activity, and smoking) were associated with RoM. Multivariate logistic regression model for the total study population identified weight loss (odds ratio [OR], 6.09; 95% confidence interval [CI], 4.14-8.83), loss of appetite (OR, 3.81; 95% CI, 2.52-5.78), age-specific low BMI (OR, 1.87; 95% CI, 1.18-2.97), number of drugs taken (OR, 1.19; 95% CI, 1.12-1.26), age (OR, 1.03; 95% CI, 1.02-1.04), and days per week with vegetable consumption (OR, 0.938; 95% CI, 0.89-0.99) as risk factors. Malnutrition in trauma and orthopedic patients is not only a problem related to age. Lifestyle-related factors also contribute significantly to malnutrition in geriatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Authenticating cache

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Tyler Barratt; Urrea, Jorge Mario

    2012-06-01

    The aim of the Authenticating Cache architecture is to ensure that machine instructions in a Read Only Memory (ROM) are legitimate from the time the ROM image is signed (immediately after compilation) to the time they are placed in the cache for the processor to consume. The proposed architecture allows the detection of ROM image modifications during distribution or when it is loaded into memory. It also ensures that modified instructions will not execute in the processor-as the cache will not be loaded with a page that fails an integrity check. The authenticity of the instruction stream can also bemore » verified in this architecture. The combination of integrity and authenticity assurance greatly improves the security profile of a system.« less

  9. Considerations for Conversion of Microfiche to Optical Storage

    DTIC Science & Technology

    1991-03-01

    139 APPENDIX C VENDORS REPLYING TO THE COMMERCE BUSINESS DAILY ADVERTISEMENT . ....... 141 APPENDIX D LIBRARY SYSTEMS EXPERT OPINION...of cooperation between the CD-ROM industry leaders including: Apple Computer Company, Digital Equipment Corporation, Hewlett-Packard, Philips, and...Sony. The leaders met in 1987 at Lake Tahoe, California to develop CD-ROM standards and are now popularly known as the "High Sierra Group". Their

  10. Aging-Related Oxidative Stress: Positive Effect of Memory Training.

    PubMed

    Pesce, Mirko; Tatangelo, Raffaella; La Fratta, Irene; Rizzuto, Alessia; Campagna, Giovanna; Turli, Cinzia; Ferrone, Alessio; Franceschelli, Sara; Speranza, Lorenza; Patruno, Antonia; Ballerini, Patrizia; De Lutiis, Maria Anna; Felaco, Mario; Grilli, Alfredo

    2018-02-01

    The cognitive impairment characterizing the phenotype of older adults has been related to the efficiency of the antioxidant system. This study aimed at investigating the effect of memory training (MT) on memory, global cognitive functioning, and the oxidant and antioxidant capacity of plasma. We recruited 52 healthy subjects aged over 60. Twenty-nine subjects were submitted to 6-months of MT (Experimental Group, EG), and 23 were used as a Control Group (CG). Global cognitive functioning was assessed by the Mini-Mental State Examination (MMSE) and Short- and Long-Term Memory (STM and LTM, respectively) by the Rey Auditory Verbal Learning Test (RAVLT) at baseline (T0) and after 6-months (T1). Meanwhile, Reactive Oxygen Metabolites derivative compounds (d-ROMs), Biological Antioxidant Potential (BAP), and their ratio were evaluated on plasma. Results showed that the MMSE and RAVLT scores improved in EG at T1. At the same time, the d-ROMs levels significantly decreased, while the BAP and BAP/d-ROMs ratio showed an opposite trend. In both groups, the MMSE and LTM scores were negatively associated with d-ROMs levels, and positively correlated with BAP levels and the BAP/d-ROMs ratio. When we considered the Δvalue (Δvariable = variable post-MT minus variable pre-MT) in EG, the ΔMMSE and ΔLTM scores were negatively associated to Δd-ROMs, and positively to ΔBAP and ΔBAP/dROM. In conclusion, our results suggest that MT improves memory and global cognitive functioning. These processes were significantly associated to increase in resistance against oxidative stress at the plasma level in healthy older adults. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Evaluation of plasma reactive oxygen metabolites levels in obese subjects with periodontal disease.

    PubMed

    Suresh, Snophia; Mahendra, Jaideep; Sudhakar, Uma; Pradeep, A R; Singh, Gurdeep

    2016-01-01

    Obesity represents the systemic condition capable of influencing the onset and progression of periodontal disease. Obesity is associated with oxidative stress. Plasma level of reactive oxidative metabolites (ROMs) is measured as an indicator of oxidative stress in the body. The aim of this study is to assess and compare the plasma ROM levels in obese subjects with healthy and inflammatory periodontal status. Sixty subjects selected were grouped as 15 obese or overweight subjects with generalized chronic periodontitis, 15 obese or overweight subjects with generalized chronic gingivitis, 15 obese or overweight subjects with healthy periodontium, and 15 nonobese and healthy periodontium. The clinical periodontal parameters such as plaque index, gingival index, probing pocket depth, and clinical attachment level were measured. Blood samples were obtained to measure the plasma levels of ROM. In this study, obese subjects with chronic periodontitis (Group I) had mean plasma ROM levels (442.3 ± 15.65 Carratelli unit [CARR U]) showing 100% subjects with high oxidative stress. Obese subjects with chronic gingivitis (Group II) had mean plasma ROM levels (358.7 ± 20.61 CARR U) indicating 86.7% subjects with oxidative stress. Obese subjects with healthy periodontium (Group III) had 46.7% subjects with slight oxidative stress, and the mean ROM level was 320.2 ± 17.57. Nonobese subjects with healthy periodontium (Group IV) had 80% of subjects with normal oxidative stress and the mean plasma ROM level was 296.9 ± 20.35 CARR U. The intra- and inter-group comparison showed significant difference (P < 0.001). From our study, we report that obese subjects with periodontitis have more oxidative stress compared to obese subjects with healthy periodontium.

  12. Development of a fully-consistent reduced order model to study instabilities in boiling water reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dykin, V.; Demaziere, C.

    2012-07-01

    A simple nonlinear Reduced Order Model to study global, regional and local instabilities in Boiling Water Reactors is described. The ROM consists of three submodels: neutron-kinetic, thermal-hydraulic and heat-transfer models. The neutron-kinetic model allows representing the time evolution of the three first neutron kinetic modes: the fundamental, the first and the second azimuthal modes. The thermal-hydraulic model describes four heated channels in order to correctly simulate out-of-phase behavior. The coupling between the different submodels is performed via both void and Doppler feedback mechanisms. After proper spatial homogenization, the governing equations are discretized in the time-domain. Several modifications, compared to othermore » existing ROMs, have been implemented, and are reported in this paper. One novelty of the ROM is the inclusion of both azimuthal modes, which allows to study combined instabilities (in-phase and out-of-phase), as well as to investigate the corresponding interference effects between them. The second modification concerns the precise estimation of so-called reactivity coefficients or C{sub mn}{sup *V,D} - coefficients by using direct cross-section data from SIMULATE-3 combined with the CORE SIM core simulator in order to calculate Eigenmodes. Furthermore, a non-uniform two-step axial power profile is introduced to simulate the separate heat production in the single and two-phase regions, respectively. An iterative procedure was developed to calculate the solution to the coupled neutron-kinetic/thermal-hydraulic static problem prior to solving the time-dependent problem. Besides, the possibility of taking into account the effect of local instabilities is demonstrated in a simplified manner. The present ROM is applied to the investigation of an actual instability that occurred at the Swedish Forsmark-1 BWR in 1996/1997. The results generated by the ROM are compared with real power plant measurements performed during stability tests and show a good qualitative agreement. The present study provides some insight in a deeper understanding of the physical principles which drive both core-wide and local instabilities. (authors)« less

  13. Feedback stabilization of an oscillating vertical cylinder by POD Reduced-Order Model

    NASA Astrophysics Data System (ADS)

    Tissot, Gilles; Cordier, Laurent; Noack, Bernd R.

    2015-01-01

    The objective is to demonstrate the use of reduced-order models (ROM) based on proper orthogonal decomposition (POD) to stabilize the flow over a vertically oscillating circular cylinder in the laminar regime (Reynolds number equal to 60). The 2D Navier-Stokes equations are first solved with a finite element method, in which the moving cylinder is introduced via an ALE method. Since in fluid-structure interaction, the POD algorithm cannot be applied directly, we implemented the fictitious domain method of Glowinski et al. [1] where the solid domain is treated as a fluid undergoing an additional constraint. The POD-ROM is classically obtained by projecting the Navier-Stokes equations onto the first POD modes. At this level, the cylinder displacement is enforced in the POD-ROM through the introduction of Lagrange multipliers. For determining the optimal vertical velocity of the cylinder, a linear quadratic regulator framework is employed. After linearization of the POD-ROM around the steady flow state, the optimal linear feedback gain is obtained as solution of a generalized algebraic Riccati equation. Finally, when the optimal feedback control is applied, it is shown that the flow converges rapidly to the steady state. In addition, a vanishing control is obtained proving the efficiency of the control approach.

  14. Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

    PubMed

    Koller, Heiko; Schmoelz, Werner; Zenner, Juliane; Auffarth, Alexander; Resch, Herbert; Hitzl, Wolfgang; Malekzadeh, Davud; Ernstbrunner, Lukas; Blocher, Martina; Mayer, Michael

    2015-12-01

    A high rate of complications in multilevel cervical surgery with corpectomies and anterior-only screw-and-plate stabilization is reported. A 360°-instrumentation improves construct stiffness and fusion rates, but adds the morbidity of a second approach. A novel ATS-technique (technique that used anterior transpedicular screw placement) was recently described, yet no study to date has analyzed its performance after fatigue loading. Accordingly, the authors performed an analysis of construct stiffness after fatigue testing of a cervical 2-level corpectomy model reconstructed using a novel anterior transpedicular screw-and-plate technique (ATS-group) in comparison to standard antero-posterior instrumentation (360°-group). Twelve fresh-frozen human cervical spines were mounted on a spine motion tester to analyze restriction of ROM under loading (1.5 Nm) in flexion-extension (FE), axial rotation (AR), and lateral bending (LB). Testing was performed in the intact state, and after instrumentation of a 2-level corpectomy C4 + C5 using a cage and the constructs of ATS- and 360°-group, after 1,000 cycles, and after 2,000 cycles of fatigue testing. In the ATS-group (n = 6), instrumentation was achieved using a customized C3-C6 ATS-plate system. In the 360°-group (n = 6), instrumentation consisted of a standard anterior screw-and-plate system with a posterior instrumentation using C3-C6 lateral mass screws. Motion data were assessed as degrees and further processed as normalized values after standardization to the intact ROM state. Specimen age and BMD were not significantly different between the ATS- and 360°-groups. After instrumentation and 2,000 cycles of testing, no specimen exhibited a ROM greater than in the intact state. No specimen exhibited catastrophic construct failure after 2,000 cycles. Construct stiffness in the 360°-group was significantly increased compared to the ATS-group for all loading conditions, except for FE-testing after instrumentation. After 2,000 cycles, restriction of ROM under loading in FE was 39.8 ± 30% in the ATS-group vs. 2.8 ± 2.3% in the 360°-group, in AR 60.4 ± 25.8 vs 15 ± 11%, and in LB 40 ± 23.4 vs 3.9 ± 1.2%. Differences were significant (p < 0.05). 360°-instrumentation resembles the biomechanical standard of reference for stabilization of 2-level corpectomies. An ATS-construct was also shown to confer high construct stiffness, significantly reducing the percentage ROM beyond that of an intact specimen after 2,000 cycles. This type of instrumentation might be a clinical valuable and biomechanically sound adjunct to multilevel anterior surgical procedures.

  15. A Smart Sensor Web for Ocean Observation: Integrated Acoustics, Satellite Networking, and Predictive Modeling

    NASA Astrophysics Data System (ADS)

    Arabshahi, P.; Chao, Y.; Chien, S.; Gray, A.; Howe, B. M.; Roy, S.

    2008-12-01

    In many areas of Earth science, including climate change research, there is a need for near real-time integration of data from heterogeneous and spatially distributed sensors, in particular in-situ and space- based sensors. The data integration, as provided by a smart sensor web, enables numerous improvements, namely, 1) adaptive sampling for more efficient use of expensive space-based sensing assets, 2) higher fidelity information gathering from data sources through integration of complementary data sets, and 3) improved sensor calibration. The specific purpose of the smart sensor web development presented here is to provide for adaptive sampling and calibration of space-based data via in-situ data. Our ocean-observing smart sensor web presented herein is composed of both mobile and fixed underwater in-situ ocean sensing assets and Earth Observing System (EOS) satellite sensors providing larger-scale sensing. An acoustic communications network forms a critical link in the web between the in-situ and space-based sensors and facilitates adaptive sampling and calibration. After an overview of primary design challenges, we report on the development of various elements of the smart sensor web. These include (a) a cable-connected mooring system with a profiler under real-time control with inductive battery charging; (b) a glider with integrated acoustic communications and broadband receiving capability; (c) satellite sensor elements; (d) an integrated acoustic navigation and communication network; and (e) a predictive model via the Regional Ocean Modeling System (ROMS). Results from field experiments, including an upcoming one in Monterey Bay (October 2008) using live data from NASA's EO-1 mission in a semi closed-loop system, together with ocean models from ROMS, are described. Plans for future adaptive sampling demonstrations using the smart sensor web are also presented.

  16. Functional analysis of rhomboid proteases during Toxoplasma invasion.

    PubMed

    Shen, Bang; Buguliskis, Jeffrey S; Lee, Tobie D; Sibley, L David

    2014-10-21

    Host cell invasion by Toxoplasma gondii and other apicomplexan parasites requires transmembrane adhesins that mediate binding to receptors on the substrate and host cell to facilitate motility and invasion. Rhomboid proteases (ROMs) are thought to cleave adhesins within their transmembrane segments, thus allowing the parasite to disengage from receptors and completely enter the host cell. To examine the specific roles of individual ROMs during invasion, we generated single, double, and triple knockouts for the three ROMs expressed in T. gondii tachyzoites. Analysis of these mutants demonstrated that ROM4 is the primary protease involved in adhesin processing and host cell invasion, whereas ROM1 or ROM5 plays negligible roles in these processes. Deletion of ROM4 blocked the shedding of adhesins such as MIC2 (microneme protein 2), causing them to accumulate on the surface of extracellular parasites. Increased surface adhesins led to nonproductive attachment, altered gliding motility, impaired moving junction formation, and reduced invasion efficiency. Despite the importance of ROM4 for efficient invasion, mutants lacking all three ROMs were viable and MIC2 was still efficiently removed from the surface of invaded mutant parasites, implying the existence of ROM-independent mechanisms for adhesin removal during invasion. Collectively, these results suggest that although ROM processing of adhesins is not absolutely essential, it is important for efficient host cell invasion by T. gondii. Importance: Apicomplexan parasites such as Toxoplasma gondii express surface proteins that bind host cell receptors to aid invasion. Many of these adhesins are subject to cleavage by rhomboid proteases (ROMs) within their transmembrane segments during invasion. Previous studies have demonstrated the importance of adhesin cleavage for parasite invasion and proposed that the ROMs responsible for processing would be essential for parasite survival. In T. gondii, ROM5 was thought to be the critical ROM for adhesin shedding due to its robust protease activity in vitro and posterior localization on the parasite surface. Here, we knocked out all three ROMs in T. gondii tachyzoites and found that ROM4, but not ROM5, was key for adhesin cleavage. However, none of the ROMs individually or in combination was essential for cell entry, further emphasizing that essential pathways such as invasion typically rely on redundant pathways to ensure survival. Copyright © 2014 Shen et al.

  17. Persistent model order reduction for complex dynamical systems using smooth orthogonal decomposition

    NASA Astrophysics Data System (ADS)

    Ilbeigi, Shahab; Chelidze, David

    2017-11-01

    Full-scale complex dynamic models are not effective for parametric studies due to the inherent constraints on available computational power and storage resources. A persistent reduced order model (ROM) that is robust, stable, and provides high-fidelity simulations for a relatively wide range of parameters and operating conditions can provide a solution to this problem. The fidelity of a new framework for persistent model order reduction of large and complex dynamical systems is investigated. The framework is validated using several numerical examples including a large linear system and two complex nonlinear systems with material and geometrical nonlinearities. While the framework is used for identifying the robust subspaces obtained from both proper and smooth orthogonal decompositions (POD and SOD, respectively), the results show that SOD outperforms POD in terms of stability, accuracy, and robustness.

  18. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  19. Modeling tides and their influence on the circulation in Prince William Sound, Alaska

    NASA Astrophysics Data System (ADS)

    Wang, Xiaochun; Chao, Yi; Zhang, Hongchun; Farrara, John; Li, Zhijin; Jin, Xin; Park, Kyungeen; Colas, Francois; McWilliams, James C.; Paternostro, Chris; Shum, C. K.; Yi, Yuchan; Schoch, Carl; Olsson, Peter

    2013-07-01

    In the process of developing a real-time data-assimilating coastal ocean forecasting system for Prince William Sound, Alaska, tidal signal was added to a three-domain nested model for the region. The model, which is configured from the Regional Ocean Modeling System (ROMS), has 40 levels in the vertical direction and horizontal resolutions of 10.6km, 3.6km and 1.2km for its three nested domains, respectively. In the present research, the ROMS tidal solution was validated using data from coastal tide gauges, satellite altimeters, high-frequency coastal radars, and Acoustic Doppler Current Profiler (ADCP) current surveys. The error of barotropic tides, as measured by the total root mean square discrepancy of eight major tidal constituents is 5.3cm, or 5.6% of the tidal sea surface height variability in the open ocean. Along the coastal region, the total discrepancy is 9.6cm, or 8.2% of the tidal sea surface height variability. Model tidal currents agree reasonably well with the observations. The influence of tides on the circulation was also investigated using numerical experiments. Besides tides, other types of forcing fields (heat flux, wind stress, evaporation minus precipitation, and freshwater discharge) were also included in the model. Our results indicate that tides play a significant role in shaping the mean circulation of the region. For the summer months, the tidal residual circulation tends to generate a cyclonic gyre in the central Sound. The net transport into the Sound through Hinchinbrook Entrance is reduced. Tides also increase the mixed layer depth in the Sound, especially during the winter months.

  20. Increased Range of Motion Is Important for Functional Outcome and Satisfaction After Total Knee Arthroplasty in Asian Patients.

    PubMed

    Ha, Chul-Won; Park, Yong-Beom; Song, Young-Suk; Kim, Jun-Ho; Park, Yong-Geun

    2016-06-01

    Although range of motion (ROM) is considered as an important factor for good outcome after total knee arthroplasty (TKA), the association of the degree of ROM with functional outcome and patient satisfaction is debated. We, therefore, investigated whether increased ROM would affect functional outcome and patient satisfaction after TKA in Asian patients. We reviewed 630 patients who underwent primary TKA with minimum 2-year follow-up. Clinical outcomes were evaluated by Knee Society (KS) score, Western Ontario and McMaster Universities osteoarthritis index, and high-flexion knee score. Patient satisfaction was evaluated using a validated questionnaire. The association of ROM and change in ROM (cROM) with clinical outcomes and satisfaction were analyzed using partial correlation analysis and multiple median regression analysis. All functional scores showed significant correlation with postoperative ROM (r = 0.129, P = .001 in Knee Society score; r = -0.101, P = .012 in Western Ontario and McMaster Universities osteoarthritis index; r = 0.183, P < .001 in high-flexion knee score). cROM correlated with satisfaction (r = 0.192, P = .005). Postoperative ROM and cROM were revealed as predisposing factors affecting function outcome using multivariable regression analysis. cROM was found as a predisposing factor affecting satisfaction. Based on the results of this study, ROM positively associated with functional outcome and cROM positively associated with patient satisfaction after TKA. These findings suggest that increased ROM after TKA is an important factor for functional outcome and satisfaction in Asian patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model.

    PubMed

    Zhang, Zhenjun; Fogel, Guy R; Liao, Zhenhua; Sun, Yitao; Liu, Weiqiang

    2018-06-01

    Lateral lumbar interbody fusion using cage supplemented with fixation has been used widely in the treatment of lumbar disease. A combined fixation (CF) of lateral plate and spinous process plate may provide multiplanar stability similar to that of bilateral pedicle screws (BPS) and may reduce morbidity. The biomechanical influence of the CF on cage subsidence and facet joint stress has not been well described. The aim of this study was to compare biomechanics of various fixation options and to verify biomechanical effects of the CF. The surgical finite element models with various fixation options were constructed based on computed tomography images. The lateral plate and posterior spinous process plate were applied (CF). The 6 motion modes were simulated. Range of motion (ROM), cage stress, endplate stress, and facet joint stress were compared. For the CF model, ROM, cage stress, and endplate stress were the minimum in almost all motion modes. Compared with BPS, the CF reduced ROM, cage stress, and endplate stress in all motion modes. The ROM was reduced by more than 10% in all motion modes except for flexion; cage stress and endplate stress were reduced more than 10% in all motion modes except for rotation-left. After interbody fusion, facet joint stress was reduced substantially compared with the intact conditions in all motion modes except for flexion. The combined plate fixation may offer an alternative to BPS fixation in lateral lumbar interbody fusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Use of the alpha shape to quantify finite helical axis dispersion during simulated spine movements.

    PubMed

    McLachlin, Stewart D; Bailey, Christopher S; Dunning, Cynthia E

    2016-01-04

    In biomechanical studies examining joint kinematics the most common measurement is range of motion (ROM), yet other techniques, such as the finite helical axis (FHA), may elucidate the changes in the 3D motion pathology more effectively. One of the deficiencies with the FHA technique is in quantifying the axes generated throughout a motion sequence. This study attempted to solve this issue via a computational geometric technique known as the alpha shape, which bounds a set of point data within a closed boundary similar to a convex hull. The purpose of this study was to use the alpha shape as an additional tool to visualize and quantify FHA dispersion between intact and injured cadaveric spine movements and compare these changes to the gold-standard ROM measurements. Flexion-extension, axial rotation, and lateral bending were simulated with five C5-C6 motion segments using a spinal loading simulator and Optotrak motion tracking system. Specimens were first tested intact followed by a simulated injury model. ROM and the FHAs were calculated post-hoc, with alpha shapes and convex hulls generated from the anatomic planar intercept points of the FHAs. While both ROM and the boundary shape areas increased with injury (p<0.05), no consistent geometric trends in the alpha shape growth were identified. The alpha shape area was sensitive to the alpha value chosen and values examined below 2.5 created more than one closed boundary. Ultimately, the alpha shape presents as a useful technique to quantify sequences of joint kinematics described by scatter plots such as FHA intercept data. Copyright © 2015. Published by Elsevier Ltd.

  3. Utility of the iPhone 4 Gyroscope Application in the Measurement of Wrist Motion.

    PubMed

    Lendner, Nuphar; Wells, Erik; Lavi, Idit; Kwok, Yan Yan; Ho, Pak-Cheong; Wollstein, Ronit

    2017-09-01

    Measurement of wrist range of motion (ROM) is important to all aspects of treatment and rehabilitation of upper extremity conditions. Recently, gyroscopes have been used to measure ROM and may be more precise than manual evaluations. The purpose of this study was to evaluate the use of the iPhone gyroscope application and compare it with use of a goniometer, specifically evaluating its accuracy and ease of use. A cross-sectional study evaluated adult Caucasian participants, with no evidence of wrist pathology. Wrist ROM measurements in 306 wrists using the 2 methods were compared. Demographic information was collected including age, sex, and occupation. Analysis included mixed models and Bland-Altman plots. Wrist motion was similar between the 2 methods. Technical difficulties were encountered with gyroscope use. Age was an independent predictor of ROM. Correct measurement of ROM is critical to guide, compare, and evaluate treatment and rehabilitation of the upper extremity. Inaccurate measurements could mislead the surgeon and harm patient adherence with therapy or surgeon instruction. An application used by the patient could improve adherence but needs to be reliable and easy to use. Evaluation is necessary before utilization of such an application. This study supports revision of the application on the iPhone to improve ease of use.

  4. Distributing the Wealth: Sliding CD-ROM into the Consumer Channel.

    ERIC Educational Resources Information Center

    Bowers, Richard A.

    1994-01-01

    Examines retail sales of CD-ROMs. Topics addressed include the current situation in CD-ROM retailing; channel distribution options; myths and realities of CD-ROM distribution; the distributor; affiliate labels; sales representatives; copublishers; distribution options; distributing resources; and recommendations for new CD-ROM publishers. (LRW)

  5. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    PubMed

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  6. Full Range of Motion Induces Greater Muscle Damage Than Partial Range of Motion in Elbow Flexion Exercise With Free Weights.

    PubMed

    Baroni, Bruno M; Pompermayer, Marcelo G; Cini, Anelize; Peruzzolo, Amanda S; Radaelli, Régis; Brusco, Clarissa M; Pinto, Ronei S

    2017-08-01

    Baroni, BM, Pompermayer, MG, Cini, A, Peruzzolo, AS, Radaelli, R, Brusco, CM, and Pinto, RS. Full range of motion induces greater muscle damage than partial range of motion in elbow flexion exercise with free weights. J Strength Cond Res 31(8): 2223-2230, 2017-Load and range of motion (ROM) applied in resistance training (RT) affect the muscle damage magnitude and the recovery time-course. Because exercises performed with partial ROM allow a higher load compared with those with full ROM, this study investigated the acute effect of a traditional RT exercise using full ROM or partial ROM on muscle damage markers. Fourteen healthy men performed 4 sets of 10 concentric-eccentric repetitions of unilateral elbow flexion on the Scott bench. Arms were randomly assigned to partial-ROM (50-100°) and full-ROM (0-130°) conditions, and load was determined as 80% of 1 repetition maximum (1RM) in the full- and partial-ROM tests. Muscle damage markers were assessed preexercise, immediately, and 24, 48, and 72 hours after exercise. Primary outcomes were peak torque, muscle soreness during palpation and elbow extension, arm circumference, and joint ROM. The load lifted in the partial-ROM condition (1RM = 19.1 ± 3.0 kg) was 40 ± 18% higher compared with the full-ROM condition (1RM = 13.7 ± 2.2 kg). Seventy-two hours after exercise, the full-ROM condition led to significant higher soreness sensation during elbow extension (1.3-4.1 cm vs. 1.0-1.9 cm) and smaller ROM values (97.5-106.1° vs. 103.6-115.7°). Peak torque, soreness from palpation, and arm circumference were statistically similar between conditions, although mean values in all time points of these outcomes have suggested more expressive muscle damage for the full-ROM condition. In conclusion, elbow flexion exercise with full ROM seems to induce greater muscle damage than partial-ROM exercises, even though higher absolute load was achieved with partial ROM.

  7. Effects of fire fighter protective ensembles on mobility and performance.

    PubMed

    Coca, Aitor; Williams, W Jon; Roberge, Raymond J; Powell, Jeffrey B

    2010-07-01

    Many studies have shown that fire fighter turnout gear and equipment may restrict mobility. The restriction of movement is usually due to a decrease in range of motion (ROM). It is important to know how much the decrease in ROM affects performance. The aim of this study was to determine the effects of fire fighter protective ensembles on mobility and performance by measuring static and dynamic range of motion (ROM) and job-related tasks. Eight healthy adults (5 males, 3 females), aged 20-40 years, participated in this study. The study consisted of measuring a battery of motions and fire fighter specific tasks while wearing a standard fire fighter ensemble (SE) or regular light clothing (baseline or BL). Several BL ROM tests were significantly (p < 0.05) different from the SE test, including a decrease in shoulder flexion, cervical rotation and flexion, trunk lateral flexion, and stand and reach. There was a significant decrease in time from SE to baseline performing the one-arm search task and object lift. These overall findings support the need for a comprehensive ergonomic evaluation of protective clothing systems to ascertain human factors issues. The development of a Standard Ergonomics Test Practice for further use in laboratories that conduct personal protective systems evaluations using human test subjects is recommended. Published by Elsevier Ltd.

  8. Construction of reduced order models for the non-linear Navier-Stokes equations using the proper orthogonal fecomposition (POD)/Galerkin method.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fike, Jeffrey A.

    2013-08-01

    The construction of stable reduced order models using Galerkin projection for the Euler or Navier-Stokes equations requires a suitable choice for the inner product. The standard L2 inner product is expected to produce unstable ROMs. For the non-linear Navier-Stokes equations this means the use of an energy inner product. In this report, Galerkin projection for the non-linear Navier-Stokes equations using the L2 inner product is implemented as a first step toward constructing stable ROMs for this set of physics.

  9. Predictability and Coupled Dynamics of MJO During DYNAMO

    DTIC Science & Technology

    2015-02-03

    with two complementary atmosphere-only simulations with modified SST conditions. One WRF simulation is forced with the persistent initial SST, lacking...we have contributed to the following subset of accomplishments of the muhi-institutional team: a. Run SC0AR2 ( WRF -ROMS) in downscaling mode for the 2...Regional (SCOAR) Model Seo et al. (2007; 2014, J. Climate), http://scoar.wlklspaces.cotn p^ WRF /RSM C^ ROMS {j^TWo-way coupling ^ One

  10. Biomechanics of the L5-S1 motion segment after total disc replacement - Influence of iatrogenic distraction, implant positioning and preoperative disc height on the range of motion and loading of facet joints.

    PubMed

    Dreischarf, Marcel; Schmidt, Hendrik; Putzier, Michael; Zander, Thomas

    2015-09-18

    Total disc replacement has been introduced to overcome negative side effects of spinal fusion. The amount of iatrogenic distraction, preoperative disc height and implant positioning have been considered important for surgical success. However, their effect on the postoperative range of motion (RoM) and loading of the facets merits further discussion. A validated osteoligamentous finite element model of the lumbosacral spine was employed and extended with four additional models to account for different disc heights. An artificial disc with a fixed center of rotation (CoR) was implemented in L5-S1. In 4000 simulations, the influence of distraction and the CoR's location on the RoM, facet joint forces (FJFs) and facet capsule ligament forces (FCLFs) was investigated. Distraction substantially altered segmental kinematics in the sagittal plane by decreasing range of flexion (0.5° per 1mm of distraction), increasing range of extension (0.7°/mm) and slightly affecting complete sagittal RoM (0.2°/mm). The distraction already strongly increased the FCLFs during surgery (up to 230N) and in flexion (~12N/mm), with higher values in models with larger preoperative disc heights, and increased FJFs in extension. A more anterior implant location decreased the RoM in all planes. In most loading cases, a more posterior location of the implant's CoR increased the FJFs and FCLFs, whereas a more caudal location increased the FCLFs but decreased the FJFs. The results of this study may explain the worse clinical results in patients with overdistraction after TDR. The complete RoM in the sagittal plane appears to be insensitive to detecting surgery-related biomechanical changes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Biomechanical evaluation of a spherical lumbar interbody device at varying levels of subsidence.

    PubMed

    Rundell, Steven A; Isaza, Jorge E; Kurtz, Steven M

    2011-01-01

    Ulf Fernström implanted stainless steel ball bearings following discectomy, or for painful disc disease, and termed this procedure disc arthroplasty. Today, spherical interbody spacers are clinically available, but there is a paucity of associated biomechanical testing. The primary objective of the current study was to evaluate the biomechanics of a spherical interbody implant. It was hypothesized that implantation of a spherical interbody implant, with combined subsidence into the vertebral bodies, would result in similar ranges of motion (RoM) and facet contact forces (FCFs) when compared with an intact condition. A secondary objective of this study was to determine the effect of using a polyetheretherketone (PEEK) versus a cobalt chrome (CoCr) implant on vertebral body strains. We hypothesized that the material selection would have a negligible effect on vertebral body strains since both materials have elastic moduli substantially greater than the annulus. A finite element model of L3-L4 was created and validated by use of ROM, disc pressure, and bony strain from previously published data. Virtual implantation of a spherical interbody device was performed with 0, 2, and 4 mm of subsidence. The model was exercised in compression, flexion, extension, axial rotation, and lateral bending. The ROM, vertebral body effective (von Mises) strain, and FCFs were reported. Implantation of a PEEK implant resulted in slightly lower strain maxima when compared with a CoCr implant. For both materials, the peak strain experienced by the underlying bone was reduced with increasing subsidence. All levels of subsidence resulted in ROM and FCFs similar to the intact model. The results suggest that a simple spherical implant design is able to maintain segmental ROM and provide minimal differences in FCFs. Large areas of von Mises strain maxima were generated in the bone adjacent to the implant regardless of whether the implant was PEEK or CoCr.

  12. CD-ROM in the High School Library [and] Some Guidelines for Purchasing a CD-ROM Workstation [and] ERIC for Librarians and Students Too [and] Online Serendipity.

    ERIC Educational Resources Information Center

    Kirsch, Robert A.; And Others

    1989-01-01

    The first article discusses CD-ROM pricing and provides a list of databases and magazines available on CD-ROM. The second provides guidelines for purchasing a CD-ROM workstation. The third describes the use of ERIC on CD-ROM as a research tool for high school students. The fourth describes the benefits of using online searching to teach research…

  13. Data from selected U.S. Geological Survey national stream water-quality monitoring networks (WQN) on CD-ROM

    USGS Publications Warehouse

    Alexander, R.B.; Ludtke, A.S.; Fitzgerald, K.K.; Schertz, T.L.

    1996-01-01

    Data from two U.S. Geological Survey (USGS) national stream water-quality monitoring networks, the National Stream Quality Accounting Network (NASQAN) and the Hydrologic Benchmark Network (HBN), are now available in a two CD-ROM set. These data on CD-ROM are collectively referred to as WQN, water-quality networks. Data from these networks have been used at the national, regional, and local levels to estimate the rates of chemical flux from watersheds, quantify changes in stream water quality for periods during the past 30 years, and investigate relations between water quality and streamflow as well as the relations of water quality to pollution sources and various physical characteristics of watersheds. The networks include 679 monitoring stations in watersheds that represent diverse climatic, physiographic, and cultural characteristics. The HBN includes 63 stations in relatively small, minimally disturbed basins ranging in size from 2 to 2,000 square miles with a median drainage basin size of 57 square miles. NASQAN includes 618 stations in larger, more culturally-influenced drainage basins ranging in size from one square mile to 1.2 million square miles with a median drainage basin size of about 4,000 square miles. The CD-ROMs contain data for 63 physical, chemical, and biological properties of water (122 total constituents including analyses of dissolved and water suspended-sediment samples) collected during more than 60,000 site visits. These data approximately span the periods 1962-95 for HBN and 1973-95 for NASQAN. The data reflect sampling over a wide range of streamflow conditions and the use of relatively consistent sampling and analytical methods. The CD-ROMs provide ancillary information and data-retrieval tools to allow the national network data to be properly and efficiently used. Ancillary information includes the following: descriptions of the network objectives and history, characteristics of the network stations and water-quality data, historical records of important changes in network sample collection and laboratory analytical methods, water reference sample data for estimating laboratory measurement bias and variability for 34 dissolved constituents for the period 1985-95, discussions of statistical methods for using water reference sample data to evaluate the accuracy of network stream water-quality data, and a bibliography of scientific investigations using national network data and other publications relevant to the networks. The data structure of the CD-ROMs is designed to allow users to efficiently enter the water-quality data to user-supplied software packages including statistical analysis, modeling, or geographic information systems. On one disc, all data are stored in ASCII form accessible from any computer system with a CD-ROM driver. The data also can be accessed using DOS-based retrieval software supplied on a second disc. This software supports logical queries of the water-quality data based on constituent concentrations, sample- collection date, river name, station name, county, state, hydrologic unit number, and 1990 population and 1987 land-cover characteristics for station watersheds. User-selected data may be output in a variety of formats including dBASE, flat ASCII, delimited ASCII, or fixed-field for subsequent use in other software packages.

  14. Wave-current interaction: Effect on the wave field in a semi-enclosed basin

    NASA Astrophysics Data System (ADS)

    Benetazzo, A.; Carniel, S.; Sclavo, M.; Bergamasco, A.

    2013-10-01

    The effect on waves of the Wave-Current Interaction (WCI) process in the semi-enclosed Gulf of Venice (northern region of the Adriatic Sea) was investigated using the Coupled Ocean-Atmosphere-Wave-Sediment Transport (COAWST) modeling system. COAWST relies on the ocean model ROMS (Regional Ocean Modeling System), the wave model SWAN (Simulating WAves Nearshore), and the CSTMS (Community Sediment Transport Modeling System) routines. The two-way data transfer between circulation and wave models was synchronous via MCT (Model Coupling Toolkit), with ROMS providing: current field, free surface elevation, and bathymetry to SWAN. For coupling, the 3-D current profiles were averaged using a formulation which integrated the near-surface velocity over a depth controlled by the spectral mean wavenumber. COAWST system was implemented on a parent grid (with horizontal resolution of 2.0 km) covering the whole Adriatic Sea with one-way nesting to a child grid resolving the northern area (Gulf of Venice) at a resolution of 0.5 km. The meteorological forcings provided by the operational meteorological model COSMO-I7 (a mesoscale model developed in the framework of the COSMO Consortium) were used to drive the modeling system in the period bracketing September 2010-August 2011. The adopted winds and the simulated waves were compared with observations at the CNR-ISMAR Acqua Alta oceanographic tower, located off the Venice littoral. Wave heights and sea surface winds were also compared with satellite-derived data. The analysis of WCI was performed on the child grid over the winter season (January-March 2011) with particular focus on the waves generated by prevailing and dominant winds blowing on the Adriatic Sea: Bora and Sirocco. Due to the variable wind direction with respect to the ocean current direction different effects on WCI were depicted, showing that within the northern Adriatic Sea the ocean-wave interactions are strongly dependent on the wind forcing direction. Further investigations reveal that, when applied to intense storms, the effect of coupling on waves results in variations of significant wave height up to 0.6 m, with some areas experiencing significant increase/decrease of wave spectral energy for opposite/following currents respectively.

  15. CD-ROM Network Configurations: Good, Better, Best!

    ERIC Educational Resources Information Center

    McClanahan, Gloria

    1996-01-01

    Rates three methods of arranging CD-ROM school networks: (1) peer-to-peer; (2) daisy chain configurations; and (3) dedicated CD-ROM file server. Describes the following network components: the file server, network adapters and wiring, the CD-ROM file server, and CD-ROM drives. Discusses issues involved in assembling these components into a working…

  16. Reactive oxygen metabolites (ROMs) are associated with cardiovascular disease in chronic hemodialysis patients.

    PubMed

    Bossola, Maurizio; Vulpio, Carlo; Colacicco, Luigi; Scribano, Donata; Zuppi, Cecilia; Tazza, Luigi

    2012-02-11

    The aim of our study was to measure reactive oxygen metabolites (ROMs) in chronic hemodialysis (HD) patients and evaluate the possible association with cardiovascular disease (CVD) and mortality. We measured ROMs in 76 HD patients and correlated with CVD, cardiovascular (CV) events in the follow-up and all-cause and CVD-related mortality. The levels of ROMs presented a median value of 270 (238.2-303.2) CARR U (interquartile range). We created a ROC curve (ROMs levels vs. CVD) and we identified a cut-off point of 273 CARR U. Patients with ROMs levels ≥273 CARR U were significantly older, had higher C-reactive protein levels and lower creatinine concentrations. The prevalence of CVD was higher in patients with ROMs levels ≥273 (87.1%) than in those with ROMs levels <273 CARR U (17.7%; p<0.0001). ROMs levels were significantly higher in patients with CVD (317±63.8) than in those without (242.7±49.1; p<0.0001). At multiple regression analysis, age, creatinine and C-reactive protein were independent factors associated with ROMs. At multiple logistic regression analysis the association between ROMs and CVD was independent (OR: 1.02, 95% CI: 1.00-1.05; p=0.03). Twenty six patients developed cardiovascular (CV) events during the follow-up. Of these, seven were in the group with ROMs levels <273 CARR U and 19 in the group with ROMs levels ≥273 CARR U. The logistic regression analysis showed that both age (OR: 1.06, 95% CI: 1.01-1.12; p=0.013) and ROMs levels (OR: 1.10, 95% CI: 1.00-1.02; p=0.045) were independently associated with CV events in the follow-up. ROMs are independently associated with CVD and predict CV events in chronic HD patients.

  17. Validity of an ankle joint motion and position sense measurement system and its application in healthy subjects and patients with ankle sprain.

    PubMed

    Lin, Chueh-Ho; Chiang, Shang-Lin; Lu, Liang-Hsuan; Wei, Shun-Hwa; Sung, Wen-Hsu

    2016-07-01

    Ankle motion and proprioception in multiple axis movements are crucial for daily activities. However, few studies have developed and used a multiple axis system for measuring ankle motion and proprioception. This study was designed to validate a novel ankle haptic interface system that measures the ankle range of motion (ROM) and joint position sense in multiple plane movements, investigating the proprioception deficits during joint position sense tasks for patients with ankle instability. Eleven healthy adults (mean ± standard deviation; age, 24.7 ± 1.9 years) and thirteen patients with ankle instability were recruited in this study. All subjects were asked to perform tests to evaluate the validity of the ankle ROM measurements and underwent tests for validating the joint position sense measurements conducted during multiple axis movements of the ankle joint. Pearson correlation was used for validating the angular position measurements obtained using the developed system; the independent t test was used to investigate the differences in joint position sense task performance for people with or without ankle instability. The ROM measurements of the device were linearly correlated with the criterion standards (r = 0.99). The ankle instability and healthy groups were significantly different in direction, absolute, and variable errors of plantar flexion, dorsiflexion, inversion, and eversion (p < 0.05). The results demonstrate that the novel ankle joint motion and position sense measurement system is valid and can be used for measuring the ankle ROM and joint position sense in multiple planes and indicate proprioception deficits for people with ankle instability. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. The Early-Warning System for incoming storm surge and tide in the Republic of Mauritius

    NASA Astrophysics Data System (ADS)

    Bogaard, Tom; de Lima Rego, Joao; Vatvani, Deepak; Virasami, Renganaden; Verlaan, Martin

    2016-04-01

    The Republic of Mauritius (ROM) is a group of islands in the South West of the Indian Ocean, consisting of the main islands of Mauritius, Rodrigues and Agalega and the archipelago of Saint Brandon. The ROM is particularly vulnerable to the adverse effects of climate change, especially in the coastal zone, where a convergence of accelerating sea level rise and increasing intensity of tropical cyclones is expected to result in considerable economic loss, humanitarian stresses, and environmental degradation. Storm surges and swell waves are expected to be aggravated through sea level rise and climate change effects on weather patterns. Adaptation to increased vulnerability requires a re-evaluation of existing preparedness measures. The focus of this project is on more effective preparedness and issuing of alerts developing a fully-automated Early-Warning System for incoming storm surge and tide, together with the Mauritius Meteorological Services and the National Disaster Risk Reduction and Management Centre (NDRRMC), such that coastal communities in Mauritius, Rodrigues and Agalega Islands are able to evacuate timely and safely in case of predicted extreme water levels. The Mauritius Early-Warning System for storm surge and tide was implemented using software from Deltares' Open-Source and free software Community. A set of five depth-averaged Delft3D-FLOW hydrodynamic models are run every six-hours with a forecast horizon of three days, simulating water levels along the coast of the three main islands. Two regional models of horizontal resolution 5km force the three detailed models of 500m resolution; all models are forced at the surface by the 0.25° NOAA/GFS meteorological forecasts. In addition, our Wind-Enhancement Scheme is used to blend detailed cyclone track bulletin's info with the larger-scale Numerical Weather Predictions. Measured data is retrieved near real-time from available Automatic Weather Stations. All these workflows are managed by the operational platform software, Delft-FEWS. The presently operational Mauritius Early-Warning System produces a set of intuitive tables for each island, containing time- and space-varying information on threshold crossings by predicted water levels. At multiple locations for each island of the ROM, the operator is informed in one glance about the recommended preparedness level, from "Safe" to "Watch", "Alert" or "Warning" based on water level forecasts. The HTML page was designed together with the MMS and the NDRRMC, in order to be easy to interpret and disseminate by local authorities.

  19. The effect of lunate position on range of motion after a four-corner arthrodesis: a biomechanical simulation study.

    PubMed

    Dvinskikh, N A; Blankevoort, L; Strackee, S D; Grimbergen, C A; Streekstra, G J

    2011-04-29

    A four-corner arthrodesis of the wrist is a salvage procedure for the treatment of specific wrist disorders, to achieve a movable, stable and pain free joint. However, a partial arthrodesis limits the postoperative range of motion (ROM). The goal of this study is to understand the mechanism of the reduction of the ROM and to evaluate the effect of the orientation of the lunate in the four-corner arthrodesis on the range of motion by using a biomechanical model, containing articular contacts and ligaments. Multi-body models of a normal wrist and a four-corner arthrodesis wrist with different orientation of the lunate were used for simulations of flexion-extension motion (FEM) and radial-ulnar deviation motion (RUD). The ROM of the postoperative wrist was reduced from 145° to 82° of the total arc of FEM and from 73° to 41.5° of the total arc of RUD. The model simulations show that the range of motion reduction is caused by overtension of the extrinsic wrist ligaments. Different positioning of the lunate changes the balance between the contact forces and ligament forces in the wrist. This explains the effect on the postoperative range of motion. The 20° flexed lunate did not give any gain in the extension motion of the wrist, caused joint luxation in flexion and limitation in RUD. The 30° extended lunate caused overtension of the extrinsic ligaments attached to the lunate. The ROM in this case is dramatically reduced. The model simulations suggest that the neutral position of the lunate seems to be most favorable for mobility of the wrist after a four-corner arthrodesis procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Comparison of Intervertebral ROM in Multi-Level Cadaveric Lumbar Spines Using Distinct Pure Moment Loading Approaches.

    PubMed

    Santoni, Brandon; Cabezas, Andres F; Cook, Daniel J; Yeager, Matthew S; Billys, James B; Whiting, Benjamin; Cheng, Boyle C

    2015-01-01

    Pure-moment loading is the test method of choice for spinal implant evaluation. However, the apparatuses and boundary conditions employed by laboratories in performing spine flexibility testing vary. The purpose of this study was to quantify the differences, if they exist, in intervertebral range of motion (ROM) resulting from different pure-moment loading apparatuses used in two laboratories. Twenty-four (laboratory A) and forty-two (laboratory B) intact L1-S1 specimens were loaded using pure moments (±7.5 Nm) in flexion-extension (FE), lateral bending (LB) and axial torsion (AT). At laboratory A, pure moments were applied using a system of cables, pulleys and suspended weights in 1.5 Nm increments. At laboratory B, specimens were loaded in a pneumatic biaxial test frame mounted with counteracting stepper-motor-driven biaxial gimbals. ROM was obtained in both labs using identical optoelectronic systems and compared. In FE, total L1-L5 ROM was similar, on average, between the two laboratories (lab A: 37.4° ± 9.1°; lab B: 35.0° ± 8.9°, p=0.289). Larger apparent differences, on average, were noted between labs in AT (lab A: 19.4° ± 7.3°; lab B: 15.7° ± 7.1°, p=0.074), and this finding was significant for combined right and left LB (lab A: 45.5° ± 11.4°; lab B: 35.3° ± 8.5°, p < 0.001). To our knowledge, this is the first study comparing ROM of multi-segment lumbar spines between laboratories utilizing different apparatuses. The results of this study show that intervertebral ROM in multi-segment lumbar spine constructs are markedly similar in FE loading. Differences in boundary conditions are likely the source of small and sometimes statistically significant differences between the two techniques in LB and AT ROM. The relative merits of each testing strategy with regard to the physiologic conditions that are to be simulated should be considered in the design of a study including LB and AT modes of loading. An understanding of these differences also serves as important information when comparing study results across different laboratories.

  1. Multiscale Reduced Order Modeling of Complex Multi-Bay Structures

    DTIC Science & Technology

    2013-07-01

    overall sound pressure level (OASPL) was 144dB and a series of 200 “snapshots” were obtained from the stationary part of the MSC /Nastran SOL 400... MSC /Nastran SOL 400, the power spectral densities computed, and their mean used for validation of the 85-mode ROM. The ROM results were obtained using...middle point of bay 5 as a function of frequency, MSC /Nastran SOL 400 and NX/Nastran SOL601. ...................... 68 4.44. Transverse displacement

  2. Solar Collectors

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Solar Energy's solar panels are collectors for a solar energy system which provides heating for a drive-in bank in Akron, OH. Collectors were designed and manufactured by Solar Energy Products, a firm established by three former NASA employees. Company President, Frank Rom, an example of a personnel-type technology transfer, was a Research Director at Lewis Research Center, which conducts extensive solar heating and cooling research, including development and testing of high-efficiency flat-plate collectors. Rom acquired solar energy expertise which helped the company develop two types of collectors, one for use in domestic/commercial heating systems and the other for drying grain.

  3. Overview of Doing Business with SPAWAR Systems Command (SPAWAR)

    DTIC Science & Technology

    2011-08-22

    School Girls Day Out FY07 – 1 school FY08 – 34 schools FY09 – 35 schools FY10 – 47 schools Material World Modules International Autonomous Underwater...s it e , a n d a ls o f rom t h e foll o vn n g link: e-CC Self -Service News The 23rd P.nnual Na v y Gold Coast Small Business O pportunity Conf...Opportunities 1. Requirements Office: Joint Program Manager - Information Systems (JPMIS) 2. Joint Effects Model (JEM) Increment 1 Sustainment 3

  4. Bringing the medical library to the office desktop.

    PubMed

    Brown, S R; Decker, G; Pletzke, C J

    1991-01-01

    This demonstration illustrates LRC Remote Computer Services- a dual operating system, multi-protocol system for delivering medical library services to the medical professional's desktop. A working model draws resources from CD-ROM and magnetic media file services, Novell and AppleTalk network protocol suites and gating, LAN and asynchronous (dial-in) access strategies, commercial applications for MS-DOS and Macintosh workstations and custom user interfaces. The demonstration includes a discussion of issues relevant to the delivery of said services, particularly with respect to maintenance, security, training/support, staffing, software licensing and costs.

  5. Maps showing geology, oil and gas fields and geological provinces of Africa

    USGS Publications Warehouse

    Persits, Feliks M.; Ahlbrandt, T.S.; Tuttle, Michele L.W.; Charpentier, R.R.; Brownfield, M.E.; Takahashi, Kenneth

    1997-01-01

    The CD-ROM was compiled according to the methodology developed by the U.S. Geological Survey's World Energy Project . The goal of the project was to assess the undiscovered, technically recoverable oil and gas resources of the world and report these results by the year 2000. A worldwide series of geologic maps, published on CD-ROMs, was released by the U.S. Geological Survey's World Energy Project during 1997 - 2000. Specific details of the data sources and map compilation are given in the metadata files on this CD-ROM. These maps were compiled using Environmental Systems Research Institute Inc. (ESRI) ARC/INFO software. Political boundaries and cartographic representations on this map are shown (with permission) from ESRI's ArcWorld 1:3M digital coverage: they have no political significance and are displayed as general reference only. Portions of this database covering the coastline and country boundaries contain proprietary property of ESRI. (Copyright 1992 and 1996, Environmental Systems Research Institute Inc. All rights reserved.)

  6. The clinical utility of cervical range of motion in diagnosis, prognosis, and evaluating the effects of manipulation: a systematic review.

    PubMed

    Snodgrass, Suzanne J; Cleland, Joshua A; Haskins, Robin; Rivett, Darren A

    2014-12-01

    Clinicians commonly assess cervical range of motion (ROM), but it has rarely been critically evaluated for its ability to contribute to patient diagnosis or prognosis, or whether it is affected by mobilisation/manipulation. This review summarises the methods used to measure cervical ROM in research involving patients with cervical spine disorders, reviews the evidence for using cervical ROM in patient diagnosis, prognosis, and evaluation of the effects of mobilisation/manipulation on cervical ROM. A systematic search of MEDLINE, EMBASE, CINAHL, AMED and ICL databases was conducted, addressing one of four constructs related to cervical ROM: measurement, diagnosis, prognosis, and the effects of mobilisation/manipulation on cervical ROM. Two independent raters appraised methodological quality using the QUADAS-2 tool for diagnostic studies, the QUIPS tool for prognostic studies and the PEDro scale for interventional studies. Heterogeneity of studies prevented meta-analysis. Thirty-six studies met the criteria and findings showed there is limited evidence for the diagnostic value of cervical ROM in cervicogenic headache, cervical radiculopathy and cervical spine injury. There is conflicting evidence for the prognostic value of cervical ROM, though restricted ROM appears associated with negative outcomes while greater ROM is associated with positive outcomes. There is conflicting evidence as to whether cervical ROM increases or decreases following mobilisation/manipulation. Cervical ROM has value as one component of assessment, but clinicians should be cautious about making clinical judgments primarily on the basis of cervical ROM. This collaboration was supported by an internal grant from the Faculty of Health, The University of Newcastle. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of shoulder internal rotation passive range of motion in various positions in nonathletic persons and the establishment of normative values for the sidelying position.

    PubMed

    Cieminski, Cort J; Kelly, Shannon M; Nawrocki, Tatia J; Indrelie, Alisse J; Klaers, Hugo; Stelzmiller, Michael R

    2016-09-01

    Loss of shoulder internal rotation (IR) range of motion (ROM) is prevalent in overhead athletes, but it can also be seen in nonathletic persons. A paucity of normative data exists, however, for shoulder IR ROM in positions other than supine, especially in nonathletic persons. The aim of this study was to determine shoulder IR ROM differences between the sidelying, semi-sidelying, and supine positions as well as to establish initial normative values for IR ROM for the sidelying and semi-sidelying positions in nonathletic persons. IR ROM was measured on 204 nonathletic persons using the sidelying, semi-sidelying, and supine positions. Mean values of IR ROM for each position were calculated. Differences in IR ROM across the 3 positions and side-to-side differences were examined, including the influence of sex and age on IR ROM. Intra-rater and inter-rater reliability for the sidelying position was excellent. The sidelying position had significantly less IR ROM compared with the other positions, and there was a significant side-to-side IR ROM difference, greatest for the sidelying position (6.8°). Women had significantly more IR ROM than men did, with sidelying normative values of 49° and 55° for female dominant and nondominant shoulders, respectively, and 42° and 51° for male dominant and nondominant shoulders, respectively. This investigation establishes initial normative IR ROM values for the sidelying position for both shoulders and sexes. Health care providers can begin to examine IR ROM deficits using these normative values for the sidelying position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. 275 C Downhole Microcomputer System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chris Hutchens; Hooi Miin Soo

    2008-08-31

    An HC11 controller IC and along with serial SRAM and ROM support ICs chip set were developed to support a data acquisition and control for extreme temperature/harsh environment conditions greater than 275 C. The 68HC11 microprocessor is widely used in well logging tools for control, data acquisition, and signal processing applications and was the logical choice for a downhole controller. This extreme temperature version of the 68HC11 enables new high temperature designs and additionally allows 68HC11-based well logging tools and MWD tools to be upgraded for high temperature operation in deep gas reservoirs, The microcomputer chip consists of the microprocessormore » ALU, a small boot ROM, 4 kbyte data RAM, counter/timer unit, serial peripheral interface (SPI), asynchronous serial interface (SCI), and the A, B, C, and D parallel ports. The chip is code compatible with the single chip mode commercial 68HC11 except for the absence of the analog to digital converter system. To avoid mask programmed internal ROM, a boot program is used to load the microcomputer program from an external mask SPI ROM. A SPI RAM IC completes the chip set and allows data RAM to be added in 4 kbyte increments. The HC11 controller IC chip set is implemented in the Peregrine Semiconductor 0.5 micron Silicon-on-Sapphire (SOS) process using a custom high temperature cell library developed at Oklahoma State University. Yield data is presented for all, the HC11, SPI-RAM and ROM. The lessons learned in this project were extended to the successful development of two high temperature versions of the LEON3 and a companion 8 Kbyte SRAM, a 200 C version for the Navy and a 275 C version for the gas industry.« less

  9. Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion.

    PubMed

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Pua, Yong-Hao; Mentiplay, Benjamin; Clark, Ross Allan

    2014-04-17

    Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine.

  10. Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion

    PubMed Central

    2014-01-01

    Background Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Findings Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1–7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant’s head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone. The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. Conclusion The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine. PMID:24742001

  11. Distribution of Databases on CD-Rom

    DTIC Science & Technology

    1990-09-01

    capabilities, advantages and disadvantages of CD-ROM technology lo determine whelher its use would be a preferred strategy for fulfilling information...capabilities, advantages and disadvantages of CD-ROM technology to determine whether its use would be a preferred strategy for fulfilling information...A. GENERAL 1 B. OBJECTIVE 1 C. RESEARCH METHODOLOGY 2 II. WHAT IS CD-ROM? 3 A. BACKGROUND 3 III. ADVANTAGES AND DISADVANTAGES OF CD-ROM

  12. Disability and Fatigue Can Be Objectively Measured in Multiple Sclerosis.

    PubMed

    Motta, Caterina; Palermo, Eduardo; Studer, Valeria; Germanotta, Marco; Germani, Giorgio; Centonze, Diego; Cappa, Paolo; Rossi, Silvia; Rossi, Stefano

    2016-01-01

    The available clinical outcome measures of disability in multiple sclerosis are not adequately responsive or sensitive. To investigate the feasibility of inertial sensor-based gait analysis in multiple sclerosis. A cross-sectional study of 80 multiple sclerosis patients and 50 healthy controls was performed. Lower-limb kinematics was evaluated by using a commercially available magnetic inertial measurement unit system. Mean and standard deviation of range of motion (mROM, sROM) for each joint of lower limbs were calculated in one minute walking test. A motor performance index (E) defined as the sum of sROMs was proposed. We established two novel observer-independent measures of disability. Hip mROM was extremely sensitive in measuring lower limb motor impairment, being correlated with muscle strength and also altered in patients without clinically detectable disability. On the other hand, E index discriminated patients according to disability, being altered only in patients with moderate and severe disability, regardless of walking speed. It was strongly correlated with fatigue and patient-perceived health status. Inertial sensor-based gait analysis is feasible and can detect clinical and subclinical disability in multiple sclerosis.

  13. A method to perform spinal motion analysis from functional X-ray images.

    PubMed

    Schulze, Martin; Trautwein, Frank; Vordemvenne, Thomas; Raschke, Michael; Heuer, Frank

    2011-06-03

    Identifying spinal instability is an important aim for proper surgical treatment. Analysis of functional X-ray images delivers measurements of the range of motion (RoM) and the center of rotation (CoR). In today's practice, CoR determination is often omitted, due to the lack of accurate methods. The aim of this work was to investigate the accuracy of a new analysis software (FXA™) based on an in vitro experiment. Six bovine spinal specimens (L3-4) were mounted in a robot (KR125, Kuka). CoRs were predefined by locking the robot actuator tool center point to the estimated position of the physiologic CoR and taking a baseline X-ray. Specimens were deflected to various RoM(preset) flexion/extension angles about the CoR(preset). Lateral functional radiographs were acquired and specimen movements were recorded using an optical motion tracking system (Optotrak Certus). RoM and CoR errors were calculated from presets for both methods. Prior to the experiment, the FXA™ software was verified with artificially generated images. For the artificial images, FXA™ yielded a mean RoM-error of 0.01 ± 0.03° (bias ± standard deviation). In the experiment, RoM-error of the FXA™-software (deviation from presets) was 0.04 ± 0.13°, and 0.10 ± 0.16° for the Optotrak, respectively. Both correlated with 0.998 (p < 0.001). For RoM < 1.0°, FXA™ determined CoR positions with a bias>20mm. This bias progressively decreased from RoM = 1° (bias = 6.0mm) to RoM = 9° (bias<1.5mm). Under the assumption that CoR location variances <5mm are clinically irrelevant on the lumbar spine, the FXA™ method can accurately determine CoRs for RoMs > 1°. Utilizing FXA™, polysegmental RoMs, CoRs and implant migration measurements could be performed in daily practice. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Knee arthritis pain is reduced and range of motion is increased following moderate pressure massage therapy.

    PubMed

    Field, Tiffany; Diego, Miguel; Gonzalez, Gladys; Funk, C G

    2015-11-01

    The literature on massage therapy effects on knee pain suggests that pain was reduced based on self-report, but little is known about range of motion (ROM) effects. Medical School staff and faculty who had knee arthritis pain were randomly assigned to a moderate pressure massage therapy or a waitlist control group (24 per group). Self-reports included the WOMAC (pain, stiffness and function) and the Pittsburgh Sleep Quality Index. ROM and ROM-related pain were assessed before and after the last sessions. The massage group showed an immediate post-massage increase in ROM and a decrease in ROM-associated pain. On the last versus the first day of the study, the massage group showed greater increases in ROM and decreases in ROM-related pain as well as less self-reported pain and sleep disturbances than the waitlist control group. These data highlight the effectiveness of moderate pressure massage therapy for increasing ROM and lessening ROM-related pain and long-term pain and sleep disturbances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Reduced-Order Models for the Aeroelastic Analysis of Ares Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Vatsa, Veer N.; Biedron, Robert T.

    2010-01-01

    This document presents the development and application of unsteady aerodynamic, structural dynamic, and aeroelastic reduced-order models (ROMs) for the ascent aeroelastic analysis of the Ares I-X flight test and Ares I crew launch vehicles using the unstructured-grid, aeroelastic FUN3D computational fluid dynamics (CFD) code. The purpose of this work is to perform computationally-efficient aeroelastic response calculations that would be prohibitively expensive via computation of multiple full-order aeroelastic FUN3D solutions. These efficient aeroelastic ROM solutions provide valuable insight regarding the aeroelastic sensitivity of the vehicles to various parameters over a range of dynamic pressures.

  16. Simulation of Dust Radiative Impact on the Red Sea Using Coupled Regional Ocean/Atmosphere Modeling System

    NASA Astrophysics Data System (ADS)

    Stenchikov, G. L.; Osipov, S.

    2016-12-01

    This study focuses on the Middle East regional climate response to the dust aerosol radiative forcing. MODIS and SEVIRI satellite observations show extremely high (exceeding 1) dust optical depths over the southern Red Sea during the summer season. The significant north-to-south gradient of the dust optical depth over the Red Sea persists throughout the entire year. The radiative forcing of dust at the sea surface exceeds 120 Wm-2. The effect of this forcing to the Red Sea thermal regime and circulations is not well quantified yet. Therefore here we employ the Regional Ocean Modeling system (ROMS) fully coupled with the Weather Research and Forecasting (WRF) model to study the impact of dust on the Red Sea. The WRF was modified to interactively account for the radiative effect of dust. Daily spectral optical properties of dust are computed using Mie, T-matrix and geometric optics approaches, and are based on the SEVIRI climatological optical depth. The WRF model parent and nested domains are configured over the Middle East and North Africa (MENA) region and over the Red Sea with 30 and 10 km resolution, respectively. The ROMS model over the Red Sea has 2 km grid spacing. The simulations show that, in the equilibrium response, dust causes 0.5-0.7K cooling of the Red Sea surface waters, and weakens the overturning circulation in the Red Sea. The salinity distribution, fresh water and heat budgets are significantly perturbed. This indicates that dust plays an important role in formation of the Red Sea energy balance and circulation regimes, and has to be thoroughly accounted for in the future modeling studies.

  17. Reliability of a Seven-Segment Foot Model with Medial and Lateral Midfoot and Forefoot Segments During Walking Gait.

    PubMed

    Cobb, Stephen C; Joshi, Mukta N; Pomeroy, Robin L

    2016-12-01

    In-vitro and invasive in-vivo studies have reported relatively independent motion in the medial and lateral forefoot segments during gait. However, most current surface-based models have not defined medial and lateral forefoot or midfoot segments. The purpose of the current study was to determine the reliability of a 7-segment foot model that includes medial and lateral midfoot and forefoot segments during walking gait. Three-dimensional positions of marker clusters located on the leg and 6 foot segments were tracked as 10 participants completed 5 walking trials. To examine the reliability of the foot model, coefficients of multiple correlation (CMC) were calculated across the trials for each participant. Three-dimensional stance time series and range of motion (ROM) during stance were also calculated for each functional articulation. CMCs for all of the functional articulations were ≥ 0.80. Overall, the rearfoot complex (leg-calcaneus segments) was the most reliable articulation and the medial midfoot complex (calcaneus-navicular segments) was the least reliable. With respect to ROM, reliability was greatest for plantarflexion/dorsiflexion and least for abduction/adduction. Further, the stance ROM and time-series patterns results between the current study and previous invasive in-vivo studies that have assessed actual bone motion were generally consistent.

  18. Associations of passive muscle stiffness, muscle stretch tolerance, and muscle slack angle with range of motion: individual and sex differences.

    PubMed

    Miyamoto, Naokazu; Hirata, Kosuke; Miyamoto-Mikami, Eri; Yasuda, Osamu; Kanehisa, Hiroaki

    2018-05-29

    Joint range of motion (ROM) is an important parameter for athletic performance and muscular injury risk. Nonetheless, a complete description of muscular factors influencing ROM among individuals and between men and women is lacking. We examined whether passive muscle stiffness (evaluated by angle-specific muscle shear modulus), tolerance to muscle stretch (evaluated by muscle shear modulus at end-ROM), and muscle slack angle of the triceps surae are associated with the individual variability and sex difference in dorsiflexion ROM, using ultrasound shear wave elastography. For men, ROM was negatively correlated to passive muscle stiffness of the medial and lateral gastrocnemius in a tensioned state and positively to tolerance to muscle stretch in the medial gastrocnemius. For women, ROM was only positively correlated to tolerance to muscle stretch in all muscles but not correlated to passive muscle stiffness. Muscle slack angle was not correlated to ROM in men and women. Significant sex differences were observed only for dorsiflexion ROM and passive muscle stiffness in a tensioned state. These findings suggest that muscular factors associated with ROM are different between men and women. Furthermore, the sex difference in dorsiflexion ROM might be attributed partly to that in passive muscle stiffness of plantar flexors.

  19. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.

    PubMed

    Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun

    2016-04-01

    To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.

  20. Effect of climate change on marine ecosystems

    NASA Astrophysics Data System (ADS)

    Vikebo, F. B.; Sundby, S.; Aadlandsvik, B.; Fiksen, O.

    2003-04-01

    As a part of the INTEGRATION project, headed by Potsdam Institute for Climate Impact Research, funded by the German Research Council, the impact of climate change scenarios on marine fish populations will be addressed on a spesific population basis and will focus on fish populations in the northern North Atlantic with special emphasis on cod. The approach taken will mainly be a modelling study supported by analysis of existing data on fish stocks and climate. Through down-scaling and nesting techniques, various climate change scenarios with reduced THC in the North Atlantic will be investigated with higher spatial resolution for selected shelf areas. The hydrodynamical model used for the regional ocean modeling is ROMS (http://marine.rutgers.edu/po/models/roms/). An individual based model will be implemented into the larval drift module to simulate growth of the larvae along the drift paths.

  1. Determination of vertebral range of motion using inertial measurement units in 27 Franches-Montagnes stallions and comparison between conditions and with a mixed population.

    PubMed

    Heim, C; Pfau, T; Gerber, V; Schweizer, C; Doherr, M; Schüpbach-Regula, G; Witte, S

    2016-07-01

    The diagnosis of equine back disorders is challenging. Objectively determining movement of the vertebral column may therefore be of value in a clinical setting. To establish whether surface-mounted inertial measurement units (IMUs) can be used to establish normal values for range of motion (ROM) of the vertebral column in a uniform population of horses trotting under different conditions. Vertebral ROM was established in Franches-Montagnes stallions and a general population of horses and the variability in measurements compared between the two groups. Repeatability and the influence of specific exercise condition (on ROM) were assessed. Finally, attempts were made to explain the findings of the study through the evaluation of factors that might influence ROM. Dorsoventral (DV) and mediolateral (ML) vertebral ROM was measured at a trot under different exercise conditions in 27 Franches-Montagnes stallions and six general population horses using IMUs distributed over the vertebral column. Variability in the ROM measurements was significantly higher for general population horses than for Franches-Montagnes stallions (both DV and ML ROM). Repeatability was strong to very strong for DV measurements and moderate for ML measurements. Trotting under saddle significantly reduced the ROM, with sitting trot resulting in a significantly lower ROM than rising trot. Age is unlikely to explain the low variability in vertebral ROM recorded in the Franches-Montagnes horses, while this may be associated with conformational factors. It was possible to establish a normal vertebral ROM for a group of Franches-Montagnes stallions. While within-breed variation was low in this population, further studies are necessary to determine variation in vertebral ROM for other breeds and to assess their utility for diagnosis of equine back disorders. © 2015 EVJ Ltd.

  2. Measurement of Shoulder Range of Motion in Patients with Adhesive Capsulitis Using a Kinect

    PubMed Central

    Chung, Sun Gun; Kim, Hee Chan; Kwak, Youngbin; Park, Hee-won; Kim, Keewon

    2015-01-01

    Range of motion (ROM) measurements are essential for the evaluation for and diagnosis of adhesive capsulitis of the shoulder (AC). However, taking these measurements using a goniometer is inconvenient and sometimes unreliable. The Kinect (Microsoft, Seattle, WA, USA) is gaining attention as a new motion detecting device that is nonintrusive and easy to implement. This study aimed to apply Kinect to measure shoulder ROM in AC; we evaluated its validity by calculating the agreement of the measurements obtained using Kinect with those obtained using goniometer and assessed its utility for the diagnosis of AC. Both shoulders of 15 healthy volunteers and affected shoulders of 12 patients with AC were included in the study. The passive and active ROM of each were measured with a goniometer for flexion, abduction, and external rotation. Their active shoulder motions for each direction were again captured using Kinect and the ROM values were calculated. The agreement between the two measurements was tested with the intraclass correlation coefficient (ICC). Diagnostic performance using the Kinect ROM was evaluated with Cohen’s kappa value. The cutoff values of the limited ROM were determined in the following ways: the same as passive ROM values, reflecting the mean difference, and based on receiver operating characteristic curves. The ICC for flexion/abduction/external rotation between goniometric passive ROM and the Kinect ROM were 0.906/0.942/0.911, while those between active ROMs and the Kinect ROMs were 0.864/0.932/0.925. Cohen’s kappa values were 0.88, 0.88, and 1.0 with the cutoff values in the order above. Measurements of the shoulder ROM using Kinect show excellent agreement with those taken using a goniometer. These results indicate that the Kinect can be used to measure shoulder ROM and to diagnose AC as an alternative to goniometer. PMID:26107943

  3. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    PubMed

    Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J

    2011-01-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  4. Evaluation of reactive oxygen metabolites in patients with non-small cell lung cancer after chemotherapy.

    PubMed

    Wakabayashi, Toru; Kawashima, Tatsuo; Matsuzawa, Yasuo

    2014-01-01

    The aim of this study was to evaluate the level of reactive oxygen metabolites (ROMs) after chemotherapy in patients with non-small cell lung cancer (NSCLC) and its association with response to treatment. Fifty-eight untreated NSCLC patients and twenty-three healthy subjects were selected for the study. Patients received two courses of platinum-based chemotherapy and were evaluated for oxidative stress and treatment response. As a marker of reactive oxygen species, ROMs levels were measured using the d-ROMs test. ROMs level (mean ± standard deviation) before chemotherapy in NSCLC patients (416 ± 135 U.CARR) was significantly elevated (p = 0.016) compared to normal healthy subjects (320 ± 59 U.CARR). Patients who responded to chemotherapy showed significantly decreased (p = 0.014) ROMs levels after chemotherapy, whereas patients who had stable disease or progressive disease showed no change in ROMs level (p = 0.387). NSCLC patients had significantly elevated ROMs levels before chemotherapy compared with normal healthy subjects. Chemotherapy may suppress ROMs production in responders but not in non-responders. ROMs level may be a predictor of clinical outcome in patients receiving chemotherapy for NSCLC.

  5. Clinical application of the Panjabi neutral zone hypothesis: the Stabilimax NZ posterior lumbar dynamic stabilization system.

    PubMed

    Yue, James J; Timm, Jens P; Panjabi, Manohar M; Jaramillo-de la Torre, Jorge

    2007-01-15

    The neutral zone (NZ) is a region of intervertebral motion around the neutral posture where little resistance is offered by the passive spinal column. The NZ appears to be a clinically important measure of spinal stability function. Its size may increase with injury to the spinal column, which in turn may result in spinal instability or low-back pain. Dynamic stabilization systems are designed to support and stabilize the spine while maintaining range of motion (ROM). The Stabilimax NZ device has been designed to reduce the NZ after spinal injury to treat pain while preserving ROM.

  6. CD-ROM preparation: An overview and guide

    NASA Technical Reports Server (NTRS)

    Daniel, Ralph E.; Jeschke, Mark W.; Schroer, James A.

    1995-01-01

    A primer on the options and procedures involved in producing CD-ROM products in a small to medium sized business operation is presented in language that persons with a minimal technical background can easily understand. The capabilities, limitations, and standards of CD-ROM technology are surveyed. Emphasis is placed on CD-ROM production, especially upon design, data conversion to an electronic medium, data file preparation, the use of vendors, and the steps for in-house production of CD-ROM products.

  7. Preparation of rotigotine-loaded microspheres and their combination use with L-DOPA to modify dyskinesias in 6-OHDA-lesioned rats.

    PubMed

    Wang, Aiping; Wang, Lexi; Sun, Kaoxiang; Liu, Wanhui; Sha, Chunjie; Li, Youxin

    2012-09-01

    To prepare rotigotine loaded microspheres (RoMS) to achieve continuous dopaminergic stimulation (CDS) for the treatment of Parkinson's disease (PD) and investigate both the therapeutic benefit and inducibility of AIMs of administration of RoMS combination with L-DOPA in 6-OHDA-leisioned rats. Rotigotine was encapsulated into poly(lactic-co-glycolic acid) (PLGA) microspheres by an oil-in-water emulsion solvent evaporation technique. In vitro characteristics and in vivo pharmacokinetics of RoMS either in rat blood or brain (by microdialysis) were investigated. Contraversive rotations and AIMs were observed to investigate the therapeutic benefit and the propensity to induce dyskinesia of RoMS or RoMS combination with L-DOPA in 6-OHDA-lesioned rats. RoMS displayed continuous-release characteristics of rotigotine in animals and exhibited a steady efficacy lasted for 2 weeks in 6-OHDA-lesioned rats. No significant difference of the therapeutic benefit between the treatment of RoMS and pulsatile L-DOPA combination and mono L-DOPA was found. While the dyskinesia was significantly decreased with the treatment of RoMS and pulsatile L-DOPA combination compared to mono L-DOPA. RoMS could supply an alternative of CDS for the treatment of PD and the study indicates a potential advantage of RoMS for the treatment of mild and advanced PD patient in combination with L-DOPA.

  8. Earth science photographs from the U.S. Geological Survey Library

    USGS Publications Warehouse

    McGregor, Joseph K.; Abston, Carl C.

    1995-01-01

    This CD-ROM set contains 1,500 scanned photographs from the U.S. Geological Survey Library for use as a photographic glossary of elementary geologic terms. Scholars are encouraged to copy these public domain images into their reports or databases to enhance their presentations. High-quality prints and (or) slides are available upon request from the library. This CD-ROM was produced in accordance with the ISO 9660 standard; however, it is intended for use on DOS-based computer systems only.

  9. Toward the Development of a Coupled COAMPS-ROMS Ensemble Kalman Filter and Adjoint with a focus on the Indian Ocean and the Intraseasonal Oscillation

    DTIC Science & Technology

    2015-09-30

    1 Approved for public release; distribution is unlimited. Toward the Development of a Coupled COAMPS-ROMS Ensemble Kalman Filter and Adjoint...system at NCAR. (2) Compare the performance of the Ensemble Kalman Filter (EnKF) using the Data Assimilation Research Testbed (DART) and 4...undercurrent is clearly visible. Figure 2 shows the horizontal temperature structure and circulation at a depth of 50 m within the surface mixed layer

  10. Spectrophotometry (by Barbara Sawrey and Gabriele Wienhausen)

    NASA Astrophysics Data System (ADS)

    Pringle, David L.

    1998-08-01

    Science Media: San Diego, 1997. 1-10 copies, 99 each; 11-20 copies, 69 each; 21+ copies, $49 each. (Note: CD operates with both Mac and PC.) Spectrophotometry is an interactive CD-ROM which introduces the basics of UV-visible spectrophotometry with some mention of infrared and other forms of spectrophotometry. A Macintosh System 7.5 or higher, CPU 68040 or Power PC processor, 6 megabytes of free RAM, 2.6 megabytes of free disk space, and 4X CD-ROM or faster are required.

  11. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position

    PubMed Central

    Cho, Kang Hee; Lee, Hyunkeun

    2016-01-01

    Objective To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. Methods One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. Results There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. Conclusion To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint. PMID:27152277

  12. An in vivo comparison study in goats for a novel motion-preserving cervical joint system

    PubMed Central

    Qin, Jie; Zhao, Chenguang; Wang, Dong; Zhao, Bo; Dong, Jun; Li, Haopeng; Sang, Rongxia; Wang, Shuang; Fu, Jiao; Kong, Rangrang

    2017-01-01

    Cervical degenerative disease is one of the most common spinal disorders worldwide, especially in older people. Anterior cervical corpectomy and fusion (ACCF) is a useful method for the surgical treatment of multi-level cervical degenerative disease. Anterior cervical disc replacement (ACDR) is considered as an alternative surgical method. However, both methods have drawbacks, particularly the neck motion decrease observed after arthrodesis, and arthroplasty should only be performed on patients presenting with cervical disc disease but without any vertebral body disease. Therefore, we designed a non-fusion cervical joint system, namely an artificial cervical vertebra and intervertebral complex (ACVC), to provide a novel treatment for multi-level cervical degenerative disease. To enhance the long-term stability of ACVC, we applied a hydroxyapatite (HA) biocoating on the surface of the artificial joint. Thirty-two goats were randomly divided into four groups: a sham control group, an ACVC group, an ACVC-HA group, and an ACCF group (titanium and plate fixation group). We performed the prosthesis implantation in our previously established goat model. We compared the clinical, radiological, biomechanical, and histological outcomes among these four different groups for 24 weeks post surgery. The goats successfully tolerated the entire experimental procedure. The kinematics data for the ACVC and ACVC-HA groups were similar. The range of motion (ROM) in adjacent level increased after ACCF but was not altered after ACVC or ACVC-HA implantation. Compared with the control group, no significant difference was found in ROM and neutral zone (NZ) in flexion-extension or lateral bending for the ACVC and ACVC-HA groups, whereas the ROM and NZ in rotation were significantly greater. Compared with the ACCF group, the ROM and NZ significantly increased in all directions. Overall, stiffness was significantly decreased in the ACVC and ACVC-HA groups compared with the control group and the ACCF group. Similar results were found after a fatigue test of 5,000 repetitions of axial rotation. The histological results showed more new bone formation and better bone implant contact in the ACVC-HA group than the ACVC group. Goat is an excellent animal model for cervical spine biomechanical study. Compared with the intact state and the ACCF group, ACVC could provide immediate stability and preserve segmental movement after discectomy and corpectomy. Besides, HA biocoating provide a better bone ingrowth, which is essential for long-term stability. In conclusion, ACVC-HA brings new insight to treat cervical degenerative disease. PMID:28582418

  13. In vitro-analysis of kinematics and intradiscal pressures in cervical arthroplasty versus fusion--A biomechanical study in a sheep model with two semi-constrained prosthesis.

    PubMed

    Daentzer, Dorothea; Welke, Bastian; Hurschler, Christof; Husmann, Nathalie; Jansen, Christina; Flamme, Christian Heinrich; Richter, Berna Ida

    2015-03-24

    As an alternative technique to arthrodesis of the cervical spine, total disc replacement (TDR) has increasingly been used with the aim of restoration of the physiological function of the treated and adjacent motions segments. The purpose of this experimental study was to analyze the kinematics of the target level as well as of the adjacent segments, and to measure the pressures in the proximal and distal disc after arthrodesis as well as after arthroplasty with two different semi-constrained types of prosthesis. Twelve cadaveric ovine cervical spines underwent polysegmental (C2-5) multidirectional flexibility testing with a sensor-guided industrial serial robot. Additionally, pressures were recorded in the proximal and distal disc. The following three conditions were tested: (1) intact specimen, (2) single-level arthrodesis C3/4, (3) single-level TDR C3/4 using the Discover® in the first six specimens and the activ® C in the other six cadavers. Statistical analysis was performed for the total range of motion (ROM), the intervertebral ROM (iROM) and the intradiscal pressures (IDP) to compare both the three different conditions as well as the two disc prosthesis among each other. The relative iROM in the target level was always lowered after fusion in the three directions of motion. In almost all cases, the relative iROM of the adjacent segments was almost always higher compared to the physiologic condition. After arthroplasty, we found increased relative iROM in the treated level in comparison to intact state in almost all cases, with relative iROM in the adjacent segments observed to be lower in almost all situations. The IDP in both adjacent discs always increased in flexion and extension after arthrodesis. In all but five cases, the IDP in each of the adjacent level was decreased below the values of the intact specimens after TDR. Overall, in none of the analyzed parameters were statistically significantly differences between both types of prostheses investigated. The results of this biomechanical study indicate that single-level implantation of semi-constrained TDR lead to a certain hypermobility in the treated segments with lowering the ROM in the adjacent levels in almost all situations.

  14. When the Chips Are Down.

    ERIC Educational Resources Information Center

    Ashton, Ray

    1995-01-01

    Strips away advertising hyperbole to explain multimedia CD-ROM technology and its place in today's classrooms. Only the newest computers are adequate for multimedia CD-ROM; only 10% of all computers in schools have CD-ROM drives attached. CD-ROM drives' performance varies, installation hassles abound, and the "edutainment" market directs…

  15. Questions to Answer before You Branch out on a CD-ROM Network.

    ERIC Educational Resources Information Center

    Simpson, Carol Mann

    1992-01-01

    Examines issues that librarians must address when purchasing databases on CD-ROM for networking. Highlights include network licenses; costs; restrictions on network rights; ownership of CD-ROMs; hardware requirements; fees for upgrading software; CD-ROM servers; pricing options; training materials; and disk drives. (LRW)

  16. Networking the Light Fantastic--CD-ROMs on LANs.

    ERIC Educational Resources Information Center

    Kittle, Paul W.

    1992-01-01

    Describes the development of a local area network (LAN) at Loma Linda University that allows remote access for both IBM and Macintosh microcomputers to CD-ROMs. Topics discussed include types of networks; fiber optic technology; networking CD-ROM drives; remote access; modems; CD-ROM databases; memory management; interface software; and future…

  17. Surface wind mixing in the Regional Ocean Modeling System (ROMS)

    NASA Astrophysics Data System (ADS)

    Robertson, Robin; Hartlipp, Paul

    2017-12-01

    Mixing at the ocean surface is key for atmosphere-ocean interactions and the distribution of heat, energy, and gases in the upper ocean. Winds are the primary force for surface mixing. To properly simulate upper ocean dynamics and the flux of these quantities within the upper ocean, models must reproduce mixing in the upper ocean. To evaluate the performance of the Regional Ocean Modeling System (ROMS) in replicating the surface mixing, the results of four different vertical mixing parameterizations were compared against observations, using the surface mixed layer depth, the temperature fields, and observed diffusivities for comparisons. The vertical mixing parameterizations investigated were Mellor- Yamada 2.5 level turbulent closure (MY), Large- McWilliams- Doney Kpp (LMD), Nakanishi- Niino (NN), and the generic length scale (GLS) schemes. This was done for one temperate site in deep water in the Eastern Pacific and three shallow water sites in the Baltic Sea. The model reproduced the surface mixed layer depth reasonably well for all sites; however, the temperature fields were reproduced well for the deep site, but not for the shallow Baltic Sea sites. In the Baltic Sea, the models overmixed the water column after a few days. Vertical temperature diffusivities were higher than those observed and did not show the temporal fluctuations present in the observations. The best performance was by NN and MY; however, MY became unstable in two of the shallow simulations with high winds. The performance of GLS nearly as good as NN and MY. LMD had the poorest performance as it generated temperature diffusivities that were too high and induced too much mixing. Further observational comparisons are needed to evaluate the effects of different stratification and wind conditions and the limitations on the vertical mixing parameterizations.

  18. Local Wind Influence on Freshwater Plume Behavior: Application to the Catalan Shelf.

    NASA Astrophysics Data System (ADS)

    Liste, Maria; Grifoll, Manel; Monbaliu, Jaak; Keupers, Ingrid; Komijani, Homayoon

    2013-04-01

    Introduction Freshwater fluxes are not always considered, and often their 3D character is neglected. The "distributed" continental run-off is seldom taken into consideration. The main aim of the EU-FP7 Field_Ac project (www.field_ac.eu), was to improve operational service for coastal areas and to generate added value for shelf and regional scale predictions including land discharge as a boundary condition. In this paper the dispersal of a fresh water plume in a small part of the Catalan Coast (NW Mediterranean Sea) caused by a flash flood event in March 2011 is presented in response to the local wind forcing. Observations and modeling results are shown for a short period but with a large impact on the receiving coastal waters. Methodology and aim For the coastal circulation model, version 3.0 of the Regional Ocean Modeling System [ROMS, Shchepetkin and McWilliams, 2005] has been chosen. ROMS solves the 3-D Reynolds-Averaged Navier-Stokes equations in sigma coordinates. The code design is modular, so that different choices for advection and mixing, for example, may be applied by simply modifying preprocessor flags. Nested increasing-resolution models have been implemented in order to reproduce with sufficient spatial resolution the coastal circulation and the river plume evolution in a small portion of the Catalan coastal area. The boundary conditions for the largest domain model are obtained from the MyOcean products. River and urban run-off are estimated based on measured or predicted rainfall in the contributing catchments areas. Conceptual models based on a reservoir-type schematization of the river and sewer network have been set up to allow for fast prediction of the different point source boundary conditions [Keupers et al., 2011]. Model output data are compared to in situ data from dedicated campaigns during the Field_AC Project and to data from operational buoys in the Catalan coastal area. Results Wind forcing leads to freshwater spreading. As expected, wind speed and direction and the magnitude of the fresh water discharge affect substantially the plume behavior. This case study illustrates clearly the need to consider both the wind forcing and the fresh water discharge as part of a single system. References Field_AC project (www.field_ac.eu), EU- FP7-SPACE-2009-1-242284. Keupers, I., Willems, P., Fernandez Sainz, J., Bricheno, L., Wolf, J., Polton, J., Howarth, J., Carniel, S., Staneva, J. (2011). Methodology (including best practice guidelines) on how to identify and incorporate 'concentrated' and 'distributed' run-off in pre-operational forecasts, based on the input and requirements from our users. FIELD_AC project, D3.1, 90 pp. MyOcean products (http://www.myocean.eu/). Shchepetkin and McWilliams, 2005. The Regional Ocean Modeling System (ROMS): A split-explicit, free-surface, topography-following coordinates ocean model. Ocean Modelling. Vol. 9 pp. 347-404.

  19. Dry wind tunnel system

    NASA Technical Reports Server (NTRS)

    Chen, Ping-Chih (Inventor)

    2013-01-01

    This invention is a ground flutter testing system without a wind tunnel, called Dry Wind Tunnel (DWT) System. The DWT system consists of a Ground Vibration Test (GVT) hardware system, a multiple input multiple output (MIMO) force controller software, and a real-time unsteady aerodynamic force generation software, that is developed from an aerodynamic reduced order model (ROM). The ground flutter test using the DWT System operates on a real structural model, therefore no scaled-down structural model, which is required by the conventional wind tunnel flutter test, is involved. Furthermore, the impact of the structural nonlinearities on the aeroelastic stability can be included automatically. Moreover, the aeroservoelastic characteristics of the aircraft can be easily measured by simply including the flight control system in-the-loop. In addition, the unsteady aerodynamics generated computationally is interference-free from the wind tunnel walls. Finally, the DWT System can be conveniently and inexpensively carried out as a post GVT test with the same hardware, only with some possible rearrangement of the shakers and the inclusion of additional sensors.

  20. Software Framework for Advanced Power Plant Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Widmann; Sorin Munteanu; Aseem Jain

    2010-08-01

    This report summarizes the work accomplished during the Phase II development effort of the Advanced Process Engineering Co-Simulator (APECS). The objective of the project is to develop the tools to efficiently combine high-fidelity computational fluid dynamics (CFD) models with process modeling software. During the course of the project, a robust integration controller was developed that can be used in any CAPE-OPEN compliant process modeling environment. The controller mediates the exchange of information between the process modeling software and the CFD software. Several approaches to reducing the time disparity between CFD simulations and process modeling have been investigated and implemented. Thesemore » include enabling the CFD models to be run on a remote cluster and enabling multiple CFD models to be run simultaneously. Furthermore, computationally fast reduced-order models (ROMs) have been developed that can be 'trained' using the results from CFD simulations and then used directly within flowsheets. Unit operation models (both CFD and ROMs) can be uploaded to a model database and shared between multiple users.« less

  1. A heterozygous putative null mutation in ROM1 without a mutation in peripherin/RDS in a family with retinitis pigmentosa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakuma, Hitoshi; Inana, G.; Murakami, Akira

    1995-05-20

    ROM1 is a 351-amino-acid, 37-kDa outer segment membrane protein of rod photoreceptors. ROM1 is related to peripherin/RDS, another outer segment membrane protein found in both rods and cones. The precise function of ROM1 or peripherin/RDS is not known, but they have been suggested to play important roles in the function and/or structure of the rod photoreceptor outer segment disks. A recent report implicated ROM1 in disease by suggesting that RP can be caused by a heterozygous null mutation in ROM1 but only in combination with another heterozygous mutation in peripherin/RDS. Screening of the ROM1 gene using polymerase chain reaction amplification,more » denaturing gradient gel electrophoresis, and direct DNA sequencing identified the same heterozygous putative null mutation in a family with RP.« less

  2. Publication of science data on CD-ROM: A guide and example

    NASA Technical Reports Server (NTRS)

    Angelici, Gary; Skiles, J. W.

    1993-01-01

    CD-ROM (Compact Disk-Read Only Memory) is becoming the standard media not only in audio recording, but also in the publication of data and information accessible on many computer platforms. Little has been written about the complicated process involved in creating easy-to-use, high quality, and useful CD-ROM's containing scientific data. This document is a manual designed to aid those who are responsible for the publication of scientific data on CD-ROM. All aspects and steps of the procedure are covered, from feasibility assessment through disk design, data preparation, disc mastering, and CD-ROM distribution. General advice and actual examples are based on lessons learned from the publication of scientific data for an interdisciplinary field experiment. Appendices include actual files from a CD-ROM, a purchase request for CD-ROM mastering services, and the disk art for the first disk published for the project.

  3. BOREAS RSS-14 Level-2 GOES-7 Shortwave and Longwave Radiation Images

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Gu, Jiujing; Smith, Eric A.

    2000-01-01

    The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. This data set contains images of shortwave and longwave radiation at the surface and top of the atmosphere derived from collected GOES-7 data. The data cover the time period of 05-Feb-1994 to 20-Sep-1994. The images missing from the temporal series were zero-filled to create a consistent sequence of files. The data are stored in binary image format files. Due to the large size of the images, the level-1a GOES-7 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1a GOES-7 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).

  4. Spatio-temporal pattern clustering for skill assessment of the Korea Operational Oceanographic System

    NASA Astrophysics Data System (ADS)

    Kim, J.; Park, K.

    2016-12-01

    In order to evaluate the performance of operational forecast models in the Korea operational oceanographic system (KOOS) which has been developed by Korea Institute of Ocean Science and Technology (KIOST), a skill assessment (SA) tool has developed and provided multiple skill metrics including not only correlation and error skills by comparing predictions and observation but also pattern clustering with numerical models, satellite, and observation. The KOOS has produced 72 hours forecast information on atmospheric and hydrodynamic forecast variables of wind, pressure, current, tide, wave, temperature, and salinity at every 12 hours per day produced by operating numerical models such as WRF, ROMS, MOM5, WW-III, and SWAN and the SA has conducted to evaluate the forecasts. We have been operationally operated several kinds of numerical models such as WRF, ROMS, MOM5, MOHID, WW-III. Quantitative assessment of operational ocean forecast model is very important to provide accurate ocean forecast information not only to general public but also to support ocean-related problems. In this work, we propose a method of pattern clustering using machine learning method and GIS-based spatial analytics to evaluate spatial distribution of numerical models and spatial observation data such as satellite and HF radar. For the clustering, we use 10 or 15 years-long reanalysis data which was computed by the KOOS, ECMWF, and HYCOM to make best matching clusters which are classified physical meaning with time variation and then we compare it with forecast data. Moreover, for evaluating current, we develop extraction method of dominant flow and apply it to hydrodynamic models and HF radar's sea surface current data. By applying pattern clustering method, it allows more accurate and effective assessment of ocean forecast models' performance by comparing not only specific observation positions which are determined by observation stations but also spatio-temporal distribution of whole model areas. We believe that our proposed method will be very useful to examine and evaluate large amount of numerical modeling data as well as satellite data.

  5. Maternal and neonatal evaluation of derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential in the horse.

    PubMed

    Sgorbini, M; Bonelli, F; Marmorini, P; Biagi, G; Corazza, M; Pasquini, A

    2015-01-01

    The aim of the present work was to evaluate derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) in mares and foals to study perinatal oxidative status. A total of 60 animals were included in the present study. Maternal and foal venous blood samples were collected immediately after delivery along with a sample drawn from one of the umbilical arteries, and plasma samples were evaluated for lactatemia, d-ROMs, and BAP. The t test for unpaired data was applied between mares versus umbilical artery blood versus foals, both for d-ROMs and BAP. The Pearson test with two-tailed P value and a confidence interval of 95% was performed between d-ROMs and BAP and between d-ROMs and lactatemia, both for mares and foals. Finally, the t test for unpaired data was performed between fillies and colts. The t test showed differences between mares versus their own foals versus umbilical artery blood but not foals versus. umbilical artery blood, both for d-ROMs and BAP. A positive correlation was found both in mares and foals between BAP and d-ROMs and in mares between lactatemia and d-ROM. No differences in gender were found in BAP concentration. Our data are in line to previous studies performed in women and cattle.

  6. Evaluation of reactive oxygen metabolites in patients with non-small cell lung cancer after chemotherapy

    PubMed Central

    2014-01-01

    Background The aim of this study was to evaluate the level of reactive oxygen metabolites (ROMs) after chemotherapy in patients with non-small cell lung cancer (NSCLC) and its association with response to treatment. Methods Fifty-eight untreated NSCLC patients and twenty-three healthy subjects were selected for the study. Patients received two courses of platinum-based chemotherapy and were evaluated for oxidative stress and treatment response. As a marker of reactive oxygen species, ROMs levels were measured using the d-ROMs test. Results ROMs level (mean ± standard deviation) before chemotherapy in NSCLC patients (416 ± 135 U.CARR) was significantly elevated (p = 0.016) compared to normal healthy subjects (320 ± 59 U.CARR). Patients who responded to chemotherapy showed significantly decreased (p = 0.014) ROMs levels after chemotherapy, whereas patients who had stable disease or progressive disease showed no change in ROMs level (p = 0.387). Conclusions NSCLC patients had significantly elevated ROMs levels before chemotherapy compared with normal healthy subjects. Chemotherapy may suppress ROMs production in responders but not in non-responders. ROMs level may be a predictor of clinical outcome in patients receiving chemotherapy for NSCLC. PMID:25180083

  7. Gait analysis and functional outcome in patients after Lisfranc injury treatment.

    PubMed

    van Hoeve, S; Stollenwerck, G; Willems, P; Witlox, M A; Meijer, K; Poeze, M

    2017-07-18

    Lisfranc injuries involve any bony or ligamentous disruption of the tarsometatarsal joint. Outcome results after treatment are mainly evaluated using patient-reported outcome measures (PROM), physical examination and radiographic findings. Less is known about the kinematics during gait. Nineteen patients (19 feet) treated for Lisfranc injury were recruited. Patients with conservative treatment and surgical treatment consisting of open reduction and internal fixation (ORIF) or primary arthrodesis were included. PROM, radiographic findings and gait analysis using the Oxford Foot Model (OFM) were analysed. Results were compared with twenty-one healthy subjects (31 feet). Multivariable logistic regression was used to determine factors influencing outcome. Patients treated for Lisfranc injury had a significantly lower walking speed than healthy subjects (P<0.001). There was a significant difference between the two groups regarding the range of motion (ROM) in the sagittal plane (flexion-extension) in the midfoot during the push-off phase (p<0.001). The ROM in the sagittal plane was significantly correlated with the AOFAS midfoot score (r 2 =0.56, p=0.012), FADI (r 2 =0.47, p=0.043) and the SF-36-physical impairment score (r 2 =0.60, p=0.007) but not with radiographic parameters for quality of reduction. In a multivariable analysis, the best explanatory factors were ROM in the sagittal plane during the push-off phase (β=0.707, p=0.001), stability (β=0.423, p=0.028) and BMI (β=-0.727 p=<0.001). This prediction model explained 87% of patient satisfaction. This study showed that patients treated for Lisfranc injury had significantly lower walking speed and significantly lower flexion/extension in the midfoot than healthy subjects. The ROM in these patients was significantly correlated with PROM, but not with radiographic quality of reduction. Most important satisfaction predictors were BMI, ROM in the sagittal plane during the push-off phase and fracture stability. Copyright © 2017. Published by Elsevier Ltd.

  8. Oxidative stress biomarker monitoring in elite women volleyball athletes during a 6-week training period.

    PubMed

    Martinović, Jelena; Dopsaj, Violeta; Kotur-Stevuljević, Jelena; Dopsaj, Milivoj; Vujović, Ana; Stefanović, Aleksandra; Nešić, Goran

    2011-05-01

    The objectives of this study were to determine (a) if reactive oxygen metabolites (ROMs) are a reliable parameter for monitoring oxidative stress in athletes alone or in association with other parameters of oxidative stress and depending on whether antioxidant supplements are taken or not; (b) the level of oxidative stress in athletes before the competition season; and (c) if oxidative status could be improved in volleyball athletes. Sixteen women athletes (supplemented group) received an antioxidant cocktail containing vitamin E, vitamin C, zinc gluconate, and selenium as a dietary supplement during a 6-week training period, whereas 12 of them (control group) received no dietary supplement. Blood samples were taken before and after the training period. The following parameters were measured: ROMs, superoxide anion (O2⁻₂), malondialdehyde (MDA), advanced oxidation protein products (AOPP), lipid hydroperoxide (LOOH), biological antioxidative potential (BAP), paraoxonase activity toward paraoxon (POase) and diazoxon (DZOase), superoxide dismutase(SOD), total sulfydryl group concentration (SH groups), and lipid status. Reactive oxygen metabolites were taken as the dependent variable and MDA, O2⁻₂, AOPP, and LOOH as independent variables. In the group of athletes who have received supplementation, linear regression analysis revealed that the implemented model had a lower influence on dROMs (70.4 vs. 27.9%) after the training period. The general linear model showed significant differences between parameters before and after training/supplementation (Wilks' lambda = 0.074, F = 11.76, p < 0.01). At the partial level, significant increases in ROM levels (p <0.05, 95% confidence interval [CI]: 286-337), SOD activity (CI: 113-144), and BAP (CI: 2,388-2,580) (p < 0.01) were observed. The association between ROMs and other parameters of oxidative stress was reduced in athletes who received supplements. During the precompetition training period, treatment with dietary supplements prevented the depletion of antioxidative defense in volleyball athletes.

  9. Significance of measuring oxidative stress in lifestyle-related diseases from the viewpoint of correlation between d-ROMs and BAP in Japanese subjects.

    PubMed

    Fukui, Toshiki; Yamauchi, Kazuhiro; Maruyama, Mie; Yasuda, Tadashi; Kohno, Masakazu; Abe, Youichi

    2011-09-01

    In recent years, oxidative stress has been postulated to be an important factor in the pathogenesis and development of lifestyle-related diseases. In this study, we investigated the association between the derivatives of reactive oxygen metabolites (d-ROMs), as an index of products of reactive oxygen species (ROS), and biological antioxidant potential (BAP), as an index of antioxidant potential. We also investigated the associations between d-ROMs or BAP and the risk factors for lifestyle-related diseases or metabolic syndrome-associated factors to evaluate their usefulness in preventive medicine. There were 442 subjects who underwent health checkup examination in our facilities. In addition to standard medical checkup items, we analyzed d-ROMs, BAP, brachial-ankle pulse wave velocity, high-sensitivity C-reactive protein level and visceral fat area (VFA) visualized on a computed tomography scan. The mean d-ROM value in females was significantly higher than that in males. There was a positive correlation between the d-ROM and VFA levels. On correlation analysis, there was a negative correlation between the d-ROM and creatinine levels. As factors that influence d-ROMs, the level of VFA was selected, suggesting the significance of oxidative stress measurement with d-ROMs. In addition, there was a positive correlation between d-ROMs and BAP values. Further research is required to resolve whether increased production of ROS or the antioxidant potential that can compensate for such an increase of ROS is more important in vivo.

  10. Collected Data of The Boreal Ecosystem and Atmosphere Study (BOREAS)

    NASA Technical Reports Server (NTRS)

    Newcomer, J. (Editor); Landis, D. (Editor); Conrad, S. (Editor); Curd, S. (Editor); Huemmrich, K. (Editor); Knapp, D. (Editor); Morrell, A. (Editor); Nickerson, J. (Editor); Papagno, A. (Editor); Rinker, D. (Editor)

    2000-01-01

    The Boreal Ecosystem-Atmosphere Study (BOREAS) was a large-scale international interdisciplinary climate-ecosystem interaction experiment in the northern boreal forests of Canada. Its goal was to improve our understanding of the boreal forests -- how they interact with the atmosphere, how much CO2 they can store, and how climate change will affect them. BOREAS wanted to learn to use satellite data to monitor the forests, and to improve computer simulation and weather models so scientists can anticipate the effects of global change. This BOREAS CD-ROM set is a set of 12 CD-ROMs containing the finalized point data sets and compressed image data from the BOREAS Project. All point data are stored in ASCII text files, and all image and GIS products are stored as binary images, compressed using GZip. Additional descriptions of the various data sets on this CD-ROM are available in other documents in the BOREAS series.

  11. Increased treatment durations lead to greater improvements in non-weight bearing dorsiflexion range of motion for asymptomatic individuals immediately following an anteroposterior grade IV mobilisation of the talus.

    PubMed

    Holland, Christopher James; Campbell, Kevin; Hutt, Kim

    2015-08-01

    Manual therapy aims to minimise pain and restore joint mobility and function. Joint mobilisations are integral to these techniques, with anteroposterior (AP) talocrural joint mobilisations purported to increase dorsiflexion range of motion (DF-ROM). This study aimed to determine whether different treatment durations of single grade IV anteroposterior talocrural joint mobilisations elicit statistically significant differences in DF-ROM. Sixteen asymptomatic male football players (age = 27.1 ± 5.3 years) participated in the study. Non-weight bearing (NWB) and weight bearing (WB) DF-ROM was measured before and after 4 randomised treatment conditions: control treatment, 30 s, 1 min, 2 min. NWB DF-ROM was measured using a universal goniometer, and WB DF-ROM using the weight-bearing lunge test. A within-subjects design was employed so that all participants received each of the treatment conditions. A 4 × 4 balanced Latin square design and 1 week interval between sessions reduced any residual effects. Two-way repeated measures ANOVA revealed a significant improvement in DF-ROM following all AP mobilisation treatments (p < 0.001). The within subjects contrasts showed that increases in treatment duration was associated with statistically significant improvements in DF-ROM (NWB DF-ROM control = 0.01%, 30 s = 14.2%, 1 min = 21.6%, 2 min = 32.8%; WB DF-ROM control = 0.01%, 30 s = 5.0%, 1 min = 7.6%, 2 min = 10.9%; p < 0.05). However, WB DF-ROM improvements were below the minimal detectable change scores needed to conclude that improvements were not a consequence of measurement error. This research shows that single session mobilisations can elicit NWB DF-ROM improvements in asymptomatic individuals in the absence of pain, whilst increases in treatment duration confer greater improvements in NWB DF-ROM within this population. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Risk factors for chronic and recurrent otitis media-a meta-analysis.

    PubMed

    Zhang, Yan; Xu, Min; Zhang, Jin; Zeng, Lingxia; Wang, Yanfei; Zheng, Qing Yin

    2014-01-01

    Risk factors associated with chronic otitis media (COM) and recurrent otitis media (ROM) have been investigated in previous studies. The objective of this study was to integrate the findings and determine the possible risk factors for COM/ROM based on our meta-analysis. A comprehensive search of electronic bibliographic databases (PubMed, Embase, CNKI and Wanfang database) from 1964 to Dec 2012, as well as a manual search of references of articles, was performed. A total of 2971 articles were searched, and 198 full-text articles were assessed for eligibility; 24 studies were eligible for this meta-analysis. Regarding risk factors for COM/ROM, there were two to nine different studies from which the odds ratios (ORs) could be pooled. The presence of allergy or atopy increased the risk of COM/ROM (OR, 1.36; 95% CI, 1.13-1.64; P = 0.001). An upper respiratory tract infection (URTI) significantly increased the risk of COM/ROM (OR, 6.59; 95% CI, 3.13-13.89; P<0.00001). Snoring appeared to be a significant risk factor for COM/ROM (OR, 1.96; 95% CI, 1.78-2.16; P<0.00001). A patient history of acute otitis media (AOM)/ROM increased the risk of COM/ROM (OR, 11.13; 95% CI, 1.06-116.44; P = 0.04). Passive smoke significantly increased the risk of COM/ROM (OR, 1.39; 95% CI, 1.02-1.89 P = 0.04). Low social status appeared to be a risk factor for COM/ROM (OR, 3.82; 95% CI, 1.11-13.15; P = 0.03). Our meta-analysis identified reliable conclusions that allergy/atopy, URTI, snoring, previous history of AOM/ROM, Second-hand smoke and low social status are important risk factors for COM/ROM. Other unidentified risk factors need to be identified in further studies with critical criteria.

  13. Risk Factors for Chronic and Recurrent Otitis Media–A Meta-Analysis

    PubMed Central

    Zhang, Yan; Xu, Min; Zhang, Jin; Zeng, Lingxia; Wang, Yanfei; Zheng, Qing Yin

    2014-01-01

    Risk factors associated with chronic otitis media (COM) and recurrent otitis media (ROM) have been investigated in previous studies. The objective of this study was to integrate the findings and determine the possible risk factors for COM/ROM based on our meta-analysis. A comprehensive search of electronic bibliographic databases (PubMed, Embase, CNKI and Wanfang database) from 1964 to Dec 2012, as well as a manual search of references of articles, was performed. A total of 2971 articles were searched, and 198 full-text articles were assessed for eligibility; 24 studies were eligible for this meta-analysis. Regarding risk factors for COM/ROM, there were two to nine different studies from which the odds ratios (ORs) could be pooled. The presence of allergy or atopy increased the risk of COM/ROM (OR, 1.36; 95% CI, 1.13–1.64; P = 0.001). An upper respiratory tract infection (URTI) significantly increased the risk of COM/ROM (OR, 6.59; 95% CI, 3.13–13.89; P<0.00001). Snoring appeared to be a significant risk factor for COM/ROM (OR, 1.96; 95% CI, 1.78–2.16; P<0.00001). A patient history of acute otitis media (AOM)/ROM increased the risk of COM/ROM (OR, 11.13; 95% CI, 1.06–116.44; P = 0.04). Passive smoke significantly increased the risk of COM/ROM (OR, 1.39; 95% CI, 1.02–1.89 P = 0.04). Low social status appeared to be a risk factor for COM/ROM (OR, 3.82; 95% CI, 1.11–13.15; P = 0.03). Our meta-analysis identified reliable conclusions that allergy/atopy, URTI, snoring, previous history of AOM/ROM, Second-hand smoke and low social status are important risk factors for COM/ROM. Other unidentified risk factors need to be identified in further studies with critical criteria. PMID:24466073

  14. Effect of shoulder taping on maximum shoulder external and internal rotation range in uninjured and previously injured overhead athletes during a seated throw.

    PubMed

    McConnell, Jenny; Donnelly, Cyril; Hamner, Samuel; Dunne, James; Besier, Thor

    2011-09-01

    The purpose of our study was to investigate whether shoulder taping affects shoulder kinematics in injured and previously injured overhead athletes during a seated throw. Twenty-six overhead college athletes threw a handball three times with and without tape, while seated on a chair. An 8-camera Vicon Motion Capture system recorded markers placed on the upper limb and trunk during each of the throwing conditions. Scaled musculoskeletal models of the upper limb were created using OpenSim and inverse kinematics used to obtain relevant joint angles. Shoulder taping had no main effect on external (ER) and internal (IR) rotation range (ROM) of the shoulder, but a significant interaction effect was found (p = 0.003 and 0.02, respectively), depending on previous injury status, whereby both the ER and IR ROM of the shoulder in the group of previously injured athletes decreased when taped (143-138° and 54-51°, respectively), but increased in the group who had never been injured (131-135° and 42-44°, respectively). Maximum abduction range and ball velocity were not affected by the application of shoulder taping, regardless of previous injury status. Thus, application of shoulder taping has a differential effect on maximum shoulder ER and IR ROM during throwing depending on previous injury status. These findings have implications for returning athletes to sport after injury and for screening athletes at risk of injury. Copyright © 2011 Orthopaedic Research Society.

  15. Altered Knee and Ankle Kinematics During Squatting in Those With Limited Weight-Bearing–Lunge Ankle-Dorsiflexion Range of Motion

    PubMed Central

    Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.

    2014-01-01

    Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury. PMID:25144599

  16. Altered knee and ankle kinematics during squatting in those with limited weight-bearing-lunge ankle-dorsiflexion range of motion.

    PubMed

    Dill, Karli E; Begalle, Rebecca L; Frank, Barnett S; Zinder, Steven M; Padua, Darin A

    2014-01-01

    Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Cross-sectional study. Sports medicine research laboratory. Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury.

  17. Cyberinfrastructure for Atmospheric Discovery

    NASA Astrophysics Data System (ADS)

    Wilhelmson, R.; Moore, C. W.

    2004-12-01

    Each year across the United States, floods, tornadoes, hail, strong winds, lightning, hurricanes, and winter storms cause hundreds of deaths, routinely disrupt transportation and commerce, and result in billions of dollars in annual economic losses . MEAD and LEAD are two recent efforts aimed at developing the cyberinfrastructure for studying and forecasting these events through collection, integration, and analysis of observational data coupled with numerical simulation, data mining, and visualization. MEAD (Modeling Environment for Atmospheric Discovery) has been funded for two years as an NCSA (National Center for Supercomputing Applications) Alliance Expedition. The goal of this expedition has been the development/adaptation of cyberinfrastructure that will enable research simulations, datamining, machine learning and visualization of hurricanes and storms utilizing the high performance computing environments including the TeraGrid. Portal grid and web infrastructure are being tested that will enable launching of hundreds of individual WRF (Weather Research and Forecasting) simulations. In a similar way, multiple Regional Ocean Modeling System (ROMS) or WRF/ROMS simulations can be carried out. Metadata and the resulting large volumes of data will then be made available for further study and for educational purposes using analysis, mining, and visualization services. Initial coupling of the ROMS and WRF codes has been completed and parallel I/O is being implemented for these models. Management of these activities (services) are being enabled through Grid workflow technologies (e.g. OGCE). LEAD (Linked Environments for Atmospheric Discovery) is a recently funded 5-year, large NSF ITR grant that involves 9 institutions who are developing a comprehensive national cyberinfrastructure in mesoscale meteorology, particularly one that can interoperate with others being developed. LEAD is addressing the fundamental information technology (IT) research challenges needed to create an integrated, scalable for identifying, accessing, preparing, assimilating, predicting, managing, analyzing, mining, and visualizing a broad array of meteorological data and model output, independent of format and physical location. A transforming element of LEAD is Workflow Orchestration for On-Demand, Real-Time, Dynamically-Adaptive Systems (WOORDS), which allows the use of analysis tools, forecast models, and data repositories as dynamically adaptive, on-demand, Grid-enabled systems that can a) change configuration rapidly and automatically in response to weather; b) continually be steered by new data; c) respond to decision-driven inputs from users; d) initiate other processes automatically; and e) steer remote observing technologies to optimize data collection for the problem at hand. Although LEAD efforts are primiarly directed at mesoscale meteorology, the IT services being developed has general applicability to other geoscience and environmental science. Integration of traditional and new data sources is a crucial component in LEAD for data analysis and assimilation, for integration of (ensemble mining) of data from sets of simulations, and for comparing results to observational data. As part of the integration effort, LEAD is creating a myLEAD metadata catalog service: a personal metacatalog that extends the Globus MCS system and is built on top of the OGSA-DAI system developed at the National e-Science Center in Edinburgh, Scotland.

  18. RehabGesture: An Alternative Tool for Measuring Human Movement.

    PubMed

    Brandão, Alexandre F; Dias, Diego R C; Castellano, Gabriela; Parizotto, Nivaldo A; Trevelin, Luis Carlos

    2016-07-01

    Systems for range of motion (ROM) measurement such as OptoTrak, Motion Capture, Motion Analysis, Vicon, and Visual 3D are so expensive that they become impracticable in public health systems and even in private rehabilitation clinics. Telerehabilitation is a branch within telemedicine intended to offer ways to increase motor and/or cognitive stimuli, aimed at faster and more effective recovery of given disabilities, and to measure kinematic data such as the improvement in ROM. In the development of the RehabGesture tool, we used the gesture recognition sensor Kinect(®) (Microsoft, Redmond, WA) and the concepts of Natural User Interface and Open Natural Interaction. RehabGesture can measure and record the ROM during rehabilitation sessions while the user interacts with the virtual reality environment. The software allows the measurement of the ROM (in the coronal plane) from 0° extension to 145° flexion of the elbow joint, as well as from 0° adduction to 180° abduction of the glenohumeral (shoulder) joint, leaving the standing position. The proposed tool has application in the fields of training and physical evaluation of professional and amateur athletes in clubs and gyms and may have application in rehabilitation and physiotherapy clinics for patients with compromised motor abilities. RehabGesture represents a low-cost solution to measure the movement of the upper limbs, as well as to stimulate the process of teaching and learning in disciplines related to the study of human movement, such as kinesiology.

  19. Disability and Fatigue Can Be Objectively Measured in Multiple Sclerosis

    PubMed Central

    Motta, Caterina; Palermo, Eduardo; Studer, Valeria; Germanotta, Marco; Germani, Giorgio; Centonze, Diego; Cappa, Paolo

    2016-01-01

    Background The available clinical outcome measures of disability in multiple sclerosis are not adequately responsive or sensitive. Objective To investigate the feasibility of inertial sensor-based gait analysis in multiple sclerosis. Methods A cross-sectional study of 80 multiple sclerosis patients and 50 healthy controls was performed. Lower-limb kinematics was evaluated by using a commercially available magnetic inertial measurement unit system. Mean and standard deviation of range of motion (mROM, sROM) for each joint of lower limbs were calculated in one minute walking test. A motor performance index (E) defined as the sum of sROMs was proposed. Results We established two novel observer-independent measures of disability. Hip mROM was extremely sensitive in measuring lower limb motor impairment, being correlated with muscle strength and also altered in patients without clinically detectable disability. On the other hand, E index discriminated patients according to disability, being altered only in patients with moderate and severe disability, regardless of walking speed. It was strongly correlated with fatigue and patient-perceived health status. Conclusions Inertial sensor-based gait analysis is feasible and can detect clinical and subclinical disability in multiple sclerosis. PMID:26863109

  20. A reduced order model to analytically infer atmospheric CO2 concentration from stomatal and climate data

    NASA Astrophysics Data System (ADS)

    Konrad, Wilfried; Katul, Gabriel; Roth-Nebelsick, Anita; Grein, Michaela

    2017-06-01

    To address questions related to the acceleration or deceleration of the global hydrological cycle or links between the carbon and water cycles over land, reliable data for past climatic conditions based on proxies are required. In particular, the reconstruction of palaeoatmospheric CO2 content (Ca) is needed to assist the separation of natural from anthropogenic Ca variability and to explore phase relations between Ca and air temperature Ta time series. Both Ta and Ca are needed to fingerprint anthropogenic signatures in vapor pressure deficit, a major driver used to explain acceleration or deceleration phases in the global hydrological cycle. Current approaches to Ca reconstruction rely on a robust inverse correlation between measured stomatal density in leaves (ν) of many plant taxa and Ca. There are two methods that exploit this correlation: The first uses calibration curves obtained from extant species assumed to represent the fossil taxa, thereby restricting the suitable taxa to those existing today. The second is a hybrid eco-hydrological/physiological approach that determines Ca with the aid of systems of equations based on quasi-instantaneous leaf-gas exchange theories and fossil stomatal data collected along with other measured leaf anatomical traits and parameters. In this contribution, a reduced order model (ROM) is proposed that derives Ca from a single equation incorporating the aforementioned stomatal data, basic climate (e.g. temperature), estimated biochemical parameters of assimilation and isotope data. The usage of the ROM is then illustrated by applying it to isotopic and anatomical measurements from three extant species. The ROM derivation is based on a balance between the biochemical demand and atmospheric supply of CO2 that leads to an explicit expression linking stomatal conductance to internal CO2 concentration (Ci) and Ca. The resulting expression of stomatal conductance from the carbon economy of the leaf is then equated to another expression derived from water vapor gas diffusion that includes anatomical traits. When combined with isotopic measurements for long-term Ci/Ca, Ca can be analytically determined and is interpreted as the time-averaged Ca that existed over the life-span of the leaf. Key advantages of the proposed ROM are: 1) the usage of isotopic data provides constraints on the reconstructed atmospheric CO2 concentration from ν, 2) the analytical form of this approach permits direct links between parameter uncertainties and reconstructed Ca, and 3) the time-scale mismatch between the application of instantaneous leaf-gas exchange expressions constrained with longer-term isotopic data is reconciled through averaging rules and sensitivity analysis. The latter point was rarely considered in prior reconstruction studies that combined models of leaf-gas exchange and isotopic data to reconstruct Ca from ν. The proposed ROM is not without its limitations given the need to a priori assume a parameter related to the control on photosynthetic rate. The work here further explores immanent constraints for the aforementioned photosynthetic parameter.

  1. Finite element analysis of moment-rotation relationships for human cervical spine.

    PubMed

    Zhang, Qing Hang; Teo, Ee Chon; Ng, Hong Wan; Lee, Vee Sin

    2006-01-01

    A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending with the inferior surface of the C7 vertebral body fully constrained were analysed. The predicted range of motion (ROM) for each motion segment were computed and compared with published experimental data. The model predicted the nonlinear moment-rotation relationship of human cervical spine. Under the same loading magnitude, the model predicted the largest rotation in extension, followed by flexion and axial rotation, and least ROM in lateral bending. The upper cervical spines are more flexible than the lower cervical levels. The motions of the two uppermost motion segments account for half (or even higher) of the whole cervical spine motion under rotational loadings. The differences in the ROMs among the lower cervical spines (C3-C7) were relatively small. The FE predicted segmental motions effectively reflect the behavior of human cervical spine and were in agreement with the experimental data. The C0-C7 FE model offers potentials for biomedical and injury studies.

  2. Integrating CD-ROM with Printed and Online Services: A Silver Platter End-User Perspective.

    ERIC Educational Resources Information Center

    Bezanson, Deborah

    1987-01-01

    Discusses the George Washington University Library's experiences as a test site for Silver Platter/Psychlit. Advantages of the CD-ROM concept, including visibility, accessibility, costs, and sophistication, are noted; crucial issues in deciding whether to acquire a CD-ROM product are considered; and CD-ROM is described as a means for integrating…

  3. Census, CD-ROM, and You! New Horizons for Microcomputer Users of Census Bureau Data.

    ERIC Educational Resources Information Center

    Bureau of the Census (DOC), Washington, DC. Data User Services Div.

    This introductory guide to Census Bureau data that is currently available to microcomputer users on compact disc (CD-ROM) begins by explaining the types of information available, how CD-ROM works, and the hardware and software required to access the databases using a microcomputer. Descriptions of data currently available on CD-ROM include…

  4. 47 CFR 61.22 - Composition of tariffs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .../2 inch (8.89 cm) diskette, or a 5 inch CD-ROM, formatted in an IBM-compatible form using either Word... tariff. The diskette or CD-ROM must be submitted in “read only” mode. The diskette or CD-ROM must be... multiple diskettes or CD-ROMs are submitted, the issuing carrier shall clearly label each diskette in the...

  5. CD-ROM Multimodal Affordances: Classroom Interaction Perspectives in the Malaysian English Literacy Hour

    ERIC Educational Resources Information Center

    Gardner, Sheena; Yaacob, Aizan

    2009-01-01

    CD-ROM affordances are explored in this article through participation in classroom interaction. CD-ROMs for shared reading of animated stories and language work were introduced to all Malaysian primary schools in 2003 for the Year 1 English Literacy Hour. We present classroom interaction extracts that show how the same CD-ROMs offer different…

  6. Oxidative stress, d-ROMs test, and ceruloplasmin.

    PubMed

    Colombini, Francesco; Carratelli, Mauro; Alberti, Angelo

    2016-01-01

    Human serum samples were evaluated for oxidative stress with the d-ROMs test. The ceruloplasmin (CP) and copper contents of the samples was independently measured and compared to those calculated on the basis of the d-ROMs test results for pure CP solutions. The d-ROMs readings did not show any significant correlation with either the CP or copper contents of the samples. Critical interference of CP on the d-ROMs test was therefore excluded and the usefulness of the test in the evaluation of global oxidative status of a biological sample could be reassessed.

  7. Electronic Document Supply Systems.

    ERIC Educational Resources Information Center

    Cawkell, A. E.

    1991-01-01

    Describes electronic document delivery systems used by libraries and document image processing systems used for business purposes. Topics discussed include technical specifications; analogue read-only laser videodiscs; compact discs and CD-ROM; WORM; facsimile; ADONIS (Article Delivery over Network Information System); DOCDEL; and systems at the…

  8. Hybrid Surgery Combined with Dynamic Stabilization System and Fusion for the Multilevel Degenerative Disease of the Lumbosacral Spine.

    PubMed

    Lee, Soo Eon; Jahng, Tae-Ahn; Kim, Hyun Jib

    2015-01-01

    As motion-preserving technique has been developed, the concept of hybrid surgery involves simultaneous application of two different kinds of devices, dynamic stabilization system and fusion technique. In the present study, the application of hybrid surgery for lumbosacral degenerative disease involving two-segments and its long-term outcome were investigated. Fifteen patients with hybrid surgery (Hybrid group) and 10 patients with two-segment fusion (Fusion group) were retrospectively compared. Preoperative grade for disc degeneration was not different between the two groups, and the most common operated segment had the most degenerated disc grade in both groups; L4-5 and L5-S1 in the Hybrid group, and L3-4 and L4-5 in Fusion group. Over 48 months of follow-up, lumbar lordosis and range of motion (ROM) at the T12-S1 global segment were preserved in the Hybrid group, and the segmental ROM at the dynamic stabilized segment maintained at final follow-up. The Fusion group had a significantly decreased global ROM and a decreased segmental ROM with larger angles compared to the Hybrid group. Defining a 2-mm decrease in posterior disc height (PDH) as radiologic adjacent segment pathology (ASP), these changes were observed in 6 and 7 patients in the Hybrid and Fusion group, respectively. However, the last PDH at the above adjacent segment had statistically higher value in Hybrid group. Pain score for back and legs was much reduced in both groups. Functional outcome measured by Oswestry disability index (ODI), however, had better improvement in Hybrid group. Hybrid surgery, combined dynamic stabilization system and fusion, can be effective surgical treatment for multilevel degenerative lumbosacral spinal disease, maintaining lumbar motion and delaying disc degeneration.

  9. Hybrid Surgery Combined with Dynamic Stabilization System and Fusion for the Multilevel Degenerative Disease of the Lumbosacral Spine

    PubMed Central

    Lee, Soo Eon; Kim, Hyun Jib

    2015-01-01

    Background As motion-preserving technique has been developed, the concept of hybrid surgery involves simultaneous application of two different kinds of devices, dynamic stabilization system and fusion technique. In the present study, the application of hybrid surgery for lumbosacral degenerative disease involving two-segments and its long-term outcome were investigated. Methods Fifteen patients with hybrid surgery (Hybrid group) and 10 patients with two-segment fusion (Fusion group) were retrospectively compared. Results Preoperative grade for disc degeneration was not different between the two groups, and the most common operated segment had the most degenerated disc grade in both groups; L4-5 and L5-S1 in the Hybrid group, and L3-4 and L4-5 in Fusion group. Over 48 months of follow-up, lumbar lordosis and range of motion (ROM) at the T12-S1 global segment were preserved in the Hybrid group, and the segmental ROM at the dynamic stabilized segment maintained at final follow-up. The Fusion group had a significantly decreased global ROM and a decreased segmental ROM with larger angles compared to the Hybrid group. Defining a 2-mm decrease in posterior disc height (PDH) as radiologic adjacent segment pathology (ASP), these changes were observed in 6 and 7 patients in the Hybrid and Fusion group, respectively. However, the last PDH at the above adjacent segment had statistically higher value in Hybrid group. Pain score for back and legs was much reduced in both groups. Functional outcome measured by Oswestry disability index (ODI), however, had better improvement in Hybrid group. Conclusion Hybrid surgery, combined dynamic stabilization system and fusion, can be effective surgical treatment for multilevel degenerative lumbosacral spinal disease, maintaining lumbar motion and delaying disc degeneration. PMID:26484008

  10. Technical Report Series on the Boreal Ecosystem-Atmosphere Study (BOREAS) RSS-19 1994 CASI At-Sensor Radiance and Reflectance Images

    NASA Technical Reports Server (NTRS)

    Miller, John; Freemantle, Jim; Nickeson, Jaime (Editor); Hall, Forrest G. (Editor); Smith, David E. (Technical Monitor)

    2000-01-01

    The Remote Sensing Science (RSS)-19 team collected Compact Airborne Spectrographic Imager (CASI) images from the Chieftain Navaho aircraft in order to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. CASI was deployed as a site-specific optical sensor during Boreal Ecosystem-Atmosphere Study (BOREAS) field campaigns. Image data were collected with CASI on 36 days during five field campaigns between February and September 1994, primarily at flux tower sites located at study sites near Thompson, Manitoba, and Prince Albert, Saskatchewan. A variety of CASI data collection strategies were used to meet the following scientific objectives: 1) canopy bidirectional reflectance, 2) canopy biochemistry, 3) spatial variability, and 4) estimates of up and downwelling Photosynthetically Active Radiation (PAR) and spectral albedo, as well as changes along transects across lakes and transects the Northern Study Area (NSA) and Southern Study Area (SSA). The images are stored as binary image files. A subset of the 1994 CASI acquisitions have been compressed and included on the BOREAS CD-ROM set. This subset includes three images for the NSA-OBS (Old Black Spruce) site on 06 Jun 94, 08 Aug 94, and 06 Sep 94, one image for the SSA-OBS site on 24 Jul 94; and one image for the NSA-Fen site on 08 Aug 94. The CASI imagery on the BOREAS CD-ROMs have been compressed using the Gzip program. The rest of the 1994 BOREAS CASI archive are not contained on the BOREAS CD-ROM set. Inventory listing files are supplied on the CD-ROM to inform users of the data that were collected. The RSS-19 1994 CASI images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

  11. The influence of variable range of motion training on neuromuscular performance and control of external loads.

    PubMed

    Clark, Ross A; Humphries, Brendan; Hohmann, Erik; Bryant, Adam L

    2011-03-01

    Resistance training programs that emphasize high force production in different regions of the range of motion (ROM) may provide performance benefits. This study examined whether variable ROM (VROM) training, which consists of partial ROM training with countermovements performed in a different phase of the ROM for each set, results in improved functional performance. Twenty-two athletes (age 22.7 ± 2.4 years, height 1.81 ± 0.07 m, and body mass 94.6 ± 14.5 kg) with extensive resistance training backgrounds performed either a VROM or full ROM control (CON) 5-week, concentric work-matched training program. The participants were assigned to a group based on stratified randomization incorporating their strength levels and performance gains in preceding training microcycles. Testing consisted of assessing the force-ROM relationship during isokinetic and isometric bench press and ballistic bench throws, with normalized electromyography amplitude assessed during the isometric tests. Repeated-measure analyses of variance revealed that the VROM intervention significantly (p < 0.05) increased both full ROM bench throw displacement (+15.5%) and half ROM bench throw peak force (+15.7%), in addition to isokinetic peak force in the terminal ROM (13.5% increase). No significant differences were observed in the CON group or between groups for any other outcome measures. Analysis of the force-ROM relationship revealed that that the VROM intervention enhanced performance at shorter muscle lengths. These findings suggest that VROM training improves terminal and midrange performance gains, resulting in the athlete possessing an improved ability to control external loading and produce dynamic force.

  12. Estaurine Freshwater Entrainment By Oyster Reefs: Quantifying A Keystone Ecosystem Service

    NASA Astrophysics Data System (ADS)

    Kaplan, D. A.; Olabarrieta, M.; Frederick, P.; Valle-Levinson, A.; Seavey, J.

    2014-12-01

    Oyster reefs have been shown to provide myriad critical ecosystem services, however their role in directing flow and currents during non-storm conditions has been largely neglected. In many regions, oyster reefs form as linear structures perpendicular to the coast and across the path of streams and rivers, potentially entraining large volumes of freshwater flow and altering nearshore mixing. We hypothesize that these reefs have the potential to influence salinity over large areas, providing a "keystone" ecosystem service by supporting multiple estuarine functions. Here we present results from a field and modeling study to quantify the effects of reef extent and elevation on estuarine salinities under varying river discharge. We found salinity differences ranging from 2 to 16 g/kg between inshore and offshore sides of degraded oyster reefs in the Suwannee Sound (FL, USA), supporting the role of reefs as local-scale freshwater dams. Moreover, differences between inshore and offshore salinities were correlated with flow, with the most marked differences during periods of low flow. Hydrodynamic modeling using the 3-D Regional Ocean Modeling System (ROMS) suggests that the currently degraded reef system entrained greater volumes of freshwater in the past, buffering the landward advance of high salinities, particularly during low flow events related to droughts. Using ROMS, we also modeled a variety of hypothetical oyster bar morphology scenarios (historical, current, and "restored") to understand how changes in reef structure (elevation, extent, and completeness) impact estuarine mixing and near-shore salinities. Taken together, these results serve to: 1) elucidate a poorly documented ecosystem service of oyster reefs; 2) provide an estimate of the magnitude and sptial extent of the freshwater entrainment effect; and 3) offer quantitative information to managers and restoration specialists interested in restoring oyster habitat.

  13. National geochemical data base; PLUTO geochemical data base for the United States

    USGS Publications Warehouse

    Baedecker, Philip A.; Grossman, Jeffrey N.; Buttleman, Kim P.

    1998-01-01

    The PLUTO CD-ROM data base contains inorganic geothermal data obtained by the analytical laboratories of the Geologic Division of the U.S. Geological Survey (USGS) for the United States, including Hawaii and Alaska, in support of USGS program activities requiring chemical data. This CD-ROM was produced in accordance with the ISO 9660 standard and can be accessed by any computer system that has the appropriate software to read the ISO 9660 discs; however, the disc is intended for use in a DOS environment.

  14. Educational use of World Wide Web pages on CD-ROM.

    PubMed

    Engel, Thomas P; Smith, Michael

    2002-01-01

    The World Wide Web is increasingly important for medical education. Internet served pages may also be used on a local hard disk or CD-ROM without a network or server. This allows authors to reuse existing content and provide access to users without a network connection. CD-ROM offers several advantages over network delivery of Web pages for several applications. However, creating Web pages for CD-ROM requires careful planning. Issues include file names, relative links, directory names, default pages, server created content, image maps, other file types and embedded programming. With care, it is possible to create server based pages that can be copied directly to CD-ROM. In addition, Web pages on CD-ROM may reference Internet served pages to provide the best features of both methods.

  15. Posterior Cruciate Ligament Retention versus Posterior Stabilization for Total Knee Arthroplasty: A Meta-Analysis.

    PubMed

    Jiang, Chao; Liu, Zhenlei; Wang, Ying; Bian, Yanyan; Feng, Bin; Weng, Xisheng

    2016-01-01

    Although being debated for many years, the superiority of posterior cruciate-retaining (CR) total knee arthroplasty (TKA) and posterior-stabilized (PS) TKA remains controversial. We compare the knee scores, post-operative knee range of motion (ROM), radiological outcomes about knee kinematic and complications between CR TKA and PS TKA. Literature published up to August 2015 was searched in PubMed, Embase and Cochrane databases, and meta-analysis was performed using the software, Review Manager version 5.3. Totally 14 random control trials (RCTs) on this topic were included for the analysis, which showed that PS and CR TKA had no significant difference in Knee Society knee Score (KSS), pain score (KSPS), Hospital for Special Surgery score (HSS), kinematic characteristics including postoperative component alignment, tibial posterior slope and joint line, and complication rate. However, PS TKA is superior to CR TKA regarding post-operative knee range of motion (ROM) [Random Effect model (RE), Mean Difference (MD) = -7.07, 95% Confidential Interval (CI) -10.50 to -3.65, p<0.0001], improvement of ROM (Fixed Effect model (FE), MD = -5.66, 95% CI -10.79 to -0.53, p = 0.03) and femoral-tibial angle [FE, MD = 0.85, 95% CI 0.46 to 1.25, p<0.0001]. There are no clinically relevant differences between CR and PS TKA in terms of clinical, functional, radiological outcome, and complications, while PS TKA is superior to CR TKA in respects of ROM, while whether this superiority matters or not in clinical practice still needs further investigation and longer follow-up.

  16. Biomechanical Analysis of Porous Additive Manufactured Cages for Lateral Lumbar Interbody Fusion: A Finite Element Analysis.

    PubMed

    Zhang, Zhenjun; Li, Hui; Fogel, Guy R; Liao, Zhenhua; Li, Yang; Liu, Weiqiang

    2018-03-01

    A porous additive manufactured (AM) cage may provide stability similar to that of traditional solid cages and may be beneficial to bone ingrowth. The biomechanical influence of various porous cages on stability, subsidence, stresses in cage, and facet contact force has not been fully described. The purpose of this study was to verify biomechanical effects of porous AM cages. The surgical finite element models with various cages were constructed. The partially porous titanium (PPT) cages and fully porous titanium (FPT) cages were applied. The mechanical parameters of porous materials were obtained by mechanical test. Then the porous AM cages were compared with solid titanium (TI) cage and solid polyetheretherketone (PEEK) cage. The 4 motion modes were simulated. Range of motion (ROM), cage stress, end plate stress, and facet joint force (FJF) were compared. For all the surgical models, ROM decreased by >90%. Compared with TI and PPT cages, PEEK and FPT cages substantially reduced the maximum stresses in cage and end plate in all motion modes. Compared with PEEK cages, the stresses in cage and end plate for FPT cages decreased, whereas the ROM increased. Comparing FPT cages, the stresses in cage and end plate decreased with increasing porosity, whereas ROM increased with increasing porosity. After interbody fusion, FJF was substantially reduced in all motion modes except for flexion. Fully porous cages may offer an alternative to solid PEEK cages in lateral lumbar interbody fusion. However, it may be prudent to further increase the porosity of the cage. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Technology Applications Group Multimedia CD-ROM Project

    NASA Technical Reports Server (NTRS)

    McRacken, Kristi D.

    1995-01-01

    To produce a multimedia CD-ROM for the Technology Applications Group which would present the Technology Opportunity Showcase (TOPS) exhibits and Small Business Innovative Research (SBIR) projects to interested companies. The CD-ROM format is being used and developed especially for those companies who do not have Internet access, and cannot directly visit Langley through the World Wide Web. The CD-ROM will include text, pictures, sound, and movies. The information for the CD-ROM will be stored in a database from which the users can query and browse the information, and future CD's can be maintained and updated.

  18. The association between menarche, intensity of training and passive joint ROM in young pre-professional female dancers: A longitudinal follow-up study.

    PubMed

    Nili, Steinberg; Shay, Tenenbaum; Myriam, Stern; Aviva, Zeev; Itzhak, Siev-Ner

    2018-05-05

    To determine the association between the status of menarche (yes/no), the intensity of training and the potential to improve passive joint range of motion (ROM) over a 12-month period of dance training. Prospective cohort study. Dance studio. Fifty-nine female dancers aged 12.8 ± 0.5. The dancers were asked about their dance intensity and screened for anthropometric parameters and passive joint ROM in Grades 7 and 8. Along the 12 months of dance training, we found significantly increased ankle-foot en-pointe, hip abduction, and hip external rotation (ER); significantly decreased hip internal rotation (IR); and significant increased hip ER:IR ratio. In Grade 7, 26 dancers (44.1%) reached menarche (Yes menarche); in Grade 8 an additional 23 dancers (39.0%) reached menarche (No/Yes menarche); and 10 dancers (16.9%) had not reached menarche (No menarche). MANOVA (mixed models) with repeated measures to compare joint ROM between the three menarche groups (Yes; No/Yes; No), with h/week dance practice as a co-variant, showed that hip ER, ankle-foot en-pointe, and ER:IR were significantly correlated with h/week in all three menarche groups. Most passive joint ROM can be improved over 12 months of dancing around the age onset of menarche. H/week of dance practice is a main factor contributing to improved hip ER, ankle-foot en-pointe and ER/IR ratio. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Brief communication: Hip joint mobility in free-ranging rhesus macaques

    PubMed Central

    Hammond, Ashley S.; Johnson, Victoria P.; Higham, James P.

    2016-01-01

    Objectives We aimed to test for differences in hip joint range of motion (ROM) between captive and free-ranging rhesus macaques (Macaca mulatta), particularly for hip joint abduction, which previous studies of captive macaques have found to be lower than predicted. Materials and Methods Hip ROM was assessed following standard joint measurement methodology in anesthetized adult free-ranging rhesus macaques (n=39) from Cayo Santiago, and compared to published ROM data from captive rhesus macaques (n=16) (Hammond 2014a, American Journal of Physical Anthropology). Significant differences between populations were detected using one-way analysis of variance (p<0.05). Results In a sample of pooled sexes and ages, free-ranging macaques are capable of increased hip abduction, flexion, and internal rotation compared to captive individuals. These differences in joint excursion resulted in free-ranging individuals having significantly increased ROM for hip adduction-abduction, rotation, flexion-extension, and the distance spanned by the knee during hip abduction. When looking at data for a smaller sample of age-matched males, fewer ROM differences are significant, but free-ranging males have significantly increased hip abduction, internal rotation, range of flexion-extension, and distance spanned by the knee during hip abduction compared to captive males of similar age. Discussion Our results suggest that a spatially restrictive environment results in decreased hip mobility in cage-confined animals and ultimately limits the potential limb postures in captive macaques. These results have implications for selection of animal samples in model validation studies, as well as laboratory animal husbandry practices. PMID:27731892

  20. Reduction in the exchange of coastal dissolved organic matter and microgels by inputs of extra riverine organic matter.

    PubMed

    Shiu, Ruei-Feng; Lee, Chon-Lin; Chin, Wei-Chun

    2017-12-15

    Rivers drive large amounts of terrestrial and riverine organic matter into oceans. These organic materials may alter the self-assembly of marine dissolved organic matter (DOM) polymers into microgels and can even affect the behavior of existing natural microgels. We used Suwannee River humic acid, fulvic acid, and natural organic matter as a model of riverine organic matter (ROM) to investigate the impacts of ROM input on DOM polymer and microgel conversion. Our results indicated that the release of extra ROM, even at low concentrations (0.1-10 mg L -1 ), into the marine organic matter pool decreased the size of self-assembled DOM polymers (from 4-5 μm to < 1 μm) and dispersed the existing natural microgels into smaller particles (from 4-5 μm to 2-3 μm). The particle size of the microgel phase was also less sensitive than that of the DOM polymers to external changes (addition of ROM). This size reduction in DOM aggregation and existing microgels may be closely tied to the surface chemistry of the organic matter, such as negative surface charge stabilization and Ca 2+ cross-linking bridges. These findings reveal that ROM inputs may therefore impede the self-assembly of DOM polymers into particulate organic matter and reduce the sedimentation flux of organic carbon and other elements from surface water to the deep ocean, thereby disturbing the biological pump, the downward transportation of nutrients, and the marine organic carbon cycle. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Feedback Control of Unsteady Flow and Vortex-Induced Vibration

    NASA Astrophysics Data System (ADS)

    Jaiman, Rajeev; Yao, Weigang

    2017-11-01

    We present an active feedback blowing and suction (AFBS) procedure via model reduction for unsteady wake flow and the vortex-induced vibration (VIV) of circular cylinders. The reduced-order model (ROM) for the AFBS procedure is developed by the eigensystem realization (ERA) algorithm, which provides a low-order representation of the unsteady flow dynamics in the neighbourhood of the equilibrium steady state. The actuation is considered via vertical suction and blowing jet at the porous surface of a circular cylinder with a body mounted force sensor. The resulting controller designed by linear low-order approximation is able to suppress the nonlinear saturated state. A systematic linear ROM-based stability analysis is performed to understand the eigenvalue distributions of elastically mounted circular cylinders. The results from the ROM analysis are consistent with those obtained from full nonlinear fluid-structure interaction simulations. A sensitivity study on the number of suction/blowing actuators, the angular arrangement of actuators, and the combined versus independent control architectures has been performed. Overall, the proposed control is found to be effective in suppressing the vortex street and the VIV for a range of reduced velocities and mass ratios.

  2. Dynamic response characteristics of dual flow-path integrally bladed rotors

    NASA Astrophysics Data System (ADS)

    Beck, Joseph A.; Brown, Jeffrey M.; Scott-Emuakpor, Onome E.; Cross, Charles J.; Slater, Joseph C.

    2015-02-01

    New turbine engine designs requiring secondary flow compression often look to dual flow-path integrally bladed rotors (DFIBRs) since these stages have the ability to perform work on the secondary, or bypassed, flow-field. While analogous to traditional integrally bladed rotor stages, DFIBR designs have many differences that result in unique dynamic response characteristics that must be understood to avoid fatigue. This work investigates these characteristics using reduced-order models (ROMs) that incorporate mistuning through perturbations to blade frequencies. This work provides an alternative to computationally intensive geometric-mistuning approaches for DFIBRs by utilizing tuned blade mode reductions and substructure coupling in cyclic coordinates. Free and forced response results are compared to full finite element model (FEM) solutions to determine if any errors are related to the reduced-order model formulation reduction methods. It is shown that DFIBRs have many more frequency veering regions than their single flow-path integrally blade rotor (IBR) counterparts. Modal families are shown to transition between system, inner-blade, and outer-blade motion. Furthermore, findings illustrate that while mode localization of traditional IBRs is limited to a single or small subset of blades, DFIBRs can have modal energy localized to either an inner- or outer-blade set resulting in many blades responding above tuned levels. Lastly, ROM forced response predictions compare well to full FEM predictions for the two test cases shown.

  3. Fast prediction and evaluation of eccentric inspirals using reduced-order models

    NASA Astrophysics Data System (ADS)

    Barta, Dániel; Vasúth, Mátyás

    2018-06-01

    A large number of theoretically predicted waveforms are required by matched-filtering searches for the gravitational-wave signals produced by compact binary coalescence. In order to substantially alleviate the computational burden in gravitational-wave searches and parameter estimation without degrading the signal detectability, we propose a novel reduced-order-model (ROM) approach with applications to adiabatic 3PN-accurate inspiral waveforms of nonspinning sources that evolve on either highly or slightly eccentric orbits. We provide a singular-value decomposition-based reduced-basis method in the frequency domain to generate reduced-order approximations of any gravitational waves with acceptable accuracy and precision within the parameter range of the model. We construct efficient reduced bases comprised of a relatively small number of the most relevant waveforms over three-dimensional parameter-space covered by the template bank (total mass 2.15 M⊙≤M ≤215 M⊙ , mass ratio 0.01 ≤q ≤1 , and initial orbital eccentricity 0 ≤e0≤0.95 ). The ROM is designed to predict signals in the frequency band from 10 Hz to 2 kHz for aLIGO and aVirgo design sensitivity. Beside moderating the data reduction, finer sampling of fiducial templates improves the accuracy of surrogates. Considerable increase in the speedup from several hundreds to thousands can be achieved by evaluating surrogates for low-mass systems especially when combined with high-eccentricity.

  4. Kino'jib'alil ri Qati't Qamam--El Pensamiento de Nuestros Abuelos (Our Grandparents' Thinking). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. Groups of students from each of the four teacher training schools re-enacted various Mayan traditions and documented them in this multimedia CD-ROM. The following presentations are included on the CD-ROM: Uxe'al nutinamit…

  5. Evaluation and application of the ROMS 1-way embedding procedure to the central california upwelling system

    NASA Astrophysics Data System (ADS)

    Penven, Pierrick; Debreu, Laurent; Marchesiello, Patrick; McWilliams, James C.

    What most clearly distinguishes near-shore and off-shore currents is their dominant spatial scale, O (1-30) km near-shore and O (30-1000) km off-shore. In practice, these phenomena are usually both measured and modeled with separate methods. In particular, it is infeasible for any regular computational grid to be large enough to simultaneously resolve well both types of currents. In order to obtain local solutions at high resolution while preserving the regional-scale circulation at an affordable computational cost, a 1-way grid embedding capability has been integrated into the Regional Oceanic Modeling System (ROMS). It takes advantage of the AGRIF (Adaptive Grid Refinement in Fortran) Fortran 90 package based on the use of pointers. After a first evaluation in a baroclinic vortex test case, the embedding procedure has been applied to a domain that covers the central upwelling region off California, around Monterey Bay, embedded in a domain that spans the continental U.S. Pacific Coast. Long-term simulations (10 years) have been conducted to obtain mean-seasonal statistical equilibria. The final solution shows few discontinuities at the parent-child domain boundary and a valid representation of the local upwelling structure, at a CPU cost only slightly greater than for the inner region alone. The solution is assessed by comparison with solutions for the whole US Pacific Coast at both low and high resolutions and to solutions for only the inner region at high resolution with mean-seasonal boundary conditions.

  6. Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.

    PubMed

    Weber, Markus; Woerner, Michael; Craiovan, Benjamin; Voellner, Florian; Worlicek, Michael; Springorum, Hans-Robert; Grifka, Joachim; Renkawitz, Tobias

    2016-12-01

    In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.

  7. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers

    PubMed Central

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-01-01

    Context: Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. Objective: To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Design: Cross-sectional study. Setting: University laboratory. Participants: Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m2). Main Outcome Measure(s): Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. Results: External-rotation ROM was greater (t38 = 4.92, P < .001), but IR ROM (t38 = −8.61, P < .001) and total ROM (t38 = −3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t38 = 2.89, P = .006) and eccentric external-rotator (t38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t38 = −3.60, P < .001). Conclusions: Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries. PMID:27813683

  8. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers.

    PubMed

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-09-01

    Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Cross-sectional study. University laboratory. Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m 2 ). Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. External-rotation ROM was greater (t 38 = 4.92, P < .001), but IR ROM (t 38 = -8.61, P < .001) and total ROM (t 38 = -3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t 38 = 2.89, P = .006) and eccentric external-rotator (t 38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t 38 = -3.60, P < .001). Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries.

  9. Impact of straight, unconnected, radially-oriented, and tapered mesopores on column efficiency: A theoretical investigation.

    PubMed

    Gritti, Fabrice

    2017-02-17

    Superficially porous particles (SPPs) can be prepared from a pseudomorphic transformation (PMT) which produces straight, unconnected, and radially-oriented mesopores (ROMs). ROMs can be either both ends open in fully porous particles (FPPs) or one-end-closed in SPPs. The impact of ROMs on the longitudinal diffusion (B/u), solid-liquid mass transfer resistance (C s u), and on the eddy dispersion (A(u)) height equivalent to a theoretical plate (HETP) of 3D randomly packed columns was investigated based on theoretical viewpoints. Torquato's theory of effective diffusion in packed beds (B term), Giddings' coupling theory of eddy dispersion (A term), and Giddings' generalized nonequilibrium theory (C s term) are applied to make predictions. First, it is found that the A term is nearly independent on the internal structure of the particle. Secondly, in the absence of flow, infinitely narrow and both ends open (no constriction effect) ROMs induce an internal hindrance factor of 23 regarding diffusion along the axial direction. Experimental data reveal that one-end-closed and 80Å wide ROMs in SPPs lead to a measurable internal hindrance factor of 27 regarding diffusion in the porous shell. Thirdly, above the optimum speed, the C s coefficient is dependent on the geometry (cylinders, cones, etc.) of the ROMs: when ROMs are conical in SPPs, C s is expected to decrease by 80% with respect to cylindrical ROMs. From an application perspective, PMT-SPPs prepared with narrow ROMs are well suited for the analysis of small molecules at or below optimum speed (lowest B term) while PMT-SPPs made of wide and conical ROMs are ideal for the analysis of large molecules above optimum speed (smallest C s term). Copyright © 2017. Published by Elsevier B.V.

  10. Relations between serum reactive oxygen metabolites (ROMs) and various inflammatory and metabolic parameters in a Japanese population.

    PubMed

    Hirose, Hiroshi; Kawabe, Hiroshi; Komiya, Naoko; Saito, Ikuo

    2009-04-01

    Both oxidative stress and inflammation are known to play roles in the pathogenesis of cardiovascular disease. We investigated the relations between reactive oxygen metabolites (ROMs) and various inflammatory and metabolic parameters in a Japanese population. We analyzed 48 male and 69 female subjects, aged 25 to 65 years, who underwent an annual health checkup in our university. Serum ROM level was assayed using a free radical elective evaluator. We also measured serum concentrations of high-sensitivity C-reactive protein (hsCRP), insulin, and high molecular weight (HMW) adiponectin. Although the serum ROM level in females (347+/-83 Carr U) was slightly higher than in males (333+/-53 Carr U), this was not statistically significant. In the 48 male subjects, the ROM level negatively correlated with age (r=-0.344, p=0.0161), and positively correlated with the hsCRP level (r=0.306, p=0.0338). In the 69 female subjects, the ROM level negatively correlated with serum creatinine (r=-0.293, p=0.0141), and positively correlated with insulin (r=0.278, p=0.0202), the insulin resistance index (r=0.286, p=0.0170) and hsCRP levels (r=0.487, p<0.0001). Stepwise multiple regression analysis revealed that serum hsCRP, creatinine, and age were independently correlated with the serum ROMs level (R2=0.365; F value highest for hsCRP). When the study subjects were divided into tertiles according to the ROM level, serum hsCRP was significantly different among the three groups: its level was highest in the highest tertile of ROMs (p<0.001). These results suggest that the serum ROM level is closely associated with serum hsCRP in Japanese adult subjects.

  11. New Products.

    ERIC Educational Resources Information Center

    TechTrends, 1992

    1992-01-01

    Reviews new educational technology products, including a microcomputer-based tutoring system, laser barcode reader, video/data projectors, CD-ROM for notebook computers, a system to increase a printer's power, data cartridge storage shell, knowledge-based decision tool, video illustrator, interactive videodiscs, surge protectors, scanner system,…

  12. Evaluation of constipation in older adults: radioopaque markers (ROMs) versus wireless motility capsule (WMC).

    PubMed

    Rao, S S C; Coss-Adame, E; Valestin, J; Mysore, K

    2012-01-01

    There is scarce information regarding assessment of constipation in older subjects. We examined regional and whole-gut transit time (WGTT) with wireless motility capsule (WMC) and compared this with radioopaque markers (ROM) transit. 39 constipated and 11 healthy older subjects (≥ 65 years) ingested a ROM capsule and WMC, wore a data receiver and kept stool diaries for 5 days. WMC recordings were analyzed for colonic transit time (CTT), WGTT and gastric emptying time (GET). Radiographs obtained on day 5 assessed ROM transit. Results for each device were compared. The CTT (p = <0.0001), WGTT (p = <0.001) and GET (p = <0.04) as measured by WMC were all slower in constipated subjects compared to healthy subjects. ROM colonic transit was also slower (p = <0.007) in constipated compared to healthy subjects. The diagnostic utility for identifying subjects with constipation as assessed by receiver operating characteristics were similar; 0.85 (WMC) versus 0.73 (ROM). Device agreement for slow colonic transit was 88% with good correlation between WMC and ROM (CTT r=0.718, p=0.0001, WGTT r=0.693, p=0.0001). Slow transit constipation was identified in 28% with ROM and 32% with WMC. No adverse events were recorded. WMC is a safe and useful device that provides objective diagnosis of delayed colonic and whole gut transit in older constipated adults. It is a radiation-free, physiologic and ambulatory technique that provides additional diagnostic information than ROM. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Long saphenous vein stripping reduces local level of reactive oxygen metabolites in patients with varicose disease of the lower limbs.

    PubMed

    Flore, Roberto; Santoliquido, Angelo; Antonio, Dal Lago; Pola, Enrico; Flex, Andrea; Pola, Roberto; Muzi, Marco Gallinella; Farinon, Attilio; Rulli, Francesco; Gaetani, Eleonora; Tondi, Paolo; Gerardino, Laura; Gasbarrini, Antonio

    2003-04-01

    Long saphenous vein (LSV) stripping is the most common surgical procedure in patients affected by varicose disease of the lower limbs. Reactive oxygen metabolites (ROM) generation plays a crucial role in chronic venous insufficiency (CVI). The aim of this study was to investigate whether ROM generation is increased in patients affected by varicose disease versus healthy controls and whether LSV stripping has a positive effect on the local production of ROM. The local production of ROM was assessed measuring hydroperoxides in the blood collected from the leg of 30 patients consecutively undergoing LSV stripping and 30 controls. In both the patient group and the control group, the test was repeated 30 days later. We found that ROM levels before surgery are higher in varicose vein patients than in controls ( p <.0001) and that ROM are significantly reduced 30 days after LSV stripping ( p <.0001). At that time point, no significant differences between patients and controls was found. We also found that sex and age do not affect ROM concentration in patients and controls, either before or after surgery. In conclusion, our data indicate that CVI is characterized by significant oxidative stress and that LSV stripping is able to normalize local production of ROM in patients with varicose disease of the lower limbs. We suggest that measurement of ROM might be useful to test the positive effects of LSV stripping in these patients.

  14. The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: an in vitro cadaveric study.

    PubMed

    Clavenna, Andrew L; Beutler, William J; Gudipally, Manasa; Moldavsky, Mark; Khalil, Saif

    2012-02-01

    Anterior cervical plating increases stability and hence improves fusion rates to treat cervical spine pathologies, which are often symptomatic at multiple levels. However, plating is not without complications, such as dysphagia, injury to neural elements, and plate breakage. The biomechanics of a spacer with integrated plate system combined with posterior instrumentation (PI), in two-level and three-level surgical models, has not yet been investigated. The purpose of the study was to biomechanically evaluate the multidirectional rigidity of spacer with integrated plate (SIP) at multiple levels as comparable to traditional spacers and plating. An in vitro cervical cadaveric model. Eight fresh human cervical (C2-C7) cadaver spines were tested under pure moments of ±1.5 Nm on spine simulator test frame. Each spine was tested in intact condition, with only anterior fixation and with both anterior and PI. Range of motion (ROM) was measured using Optotrak Certus (NDI, Inc., Waterloo, Ontario, Canada) motion analysis system in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) at the instrumented levels (C3-C6). Repeated-measures analysis of variance was used for statistical analysis. All the surgical constructs showed significant reduction in motion compared with intact condition. In two-level fusion, SIP (C4-C6) construct significantly reduced ROM by 66.5%, 65.4%, and 60.3% when compared with intact in FE, LB, and AR, respectively. In three-level fusion, SIP (C3-C6) construct significantly reduced ROM by 65.8%, 66%, and 49.6% when compared with intact in FE, LB, and AR, respectively. Posterior instrumentation showed significant stability only in three-level fusion when compared with their respective anterior constructs. In both two-level and three-level fusion, SIP showed comparable stability to traditional spacer and plate constructs in all loading modes. The anatomically profiled spacer with integrated plate allows treatment of cervical disorders with fewer steps and less impact to cervical structures. In this biomechanical study, spacer with integrated plate construct showed comparable stability to traditional spacer and plate for two-level and three-level fusion. Posterior instrumentation showed significant effect only in three-level fusion. Clinical data are required for further validation of using spacer with integrated plate at multiple levels. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. [Sociodemographic and health conditions of the Romá population in Milan].

    PubMed

    Colombo, Cinzia; Galli, Andrea; Pero, Margherita; Giani, Riccardo; Jucker, Simonetta; Oreste, Pierluigi; Giommarini, Claudia; Aiolfi, Ernestina; Judica, Elda

    2011-01-01

    To analyze the socioeconomic and health status of rom a people mainly living in not authorized settlements in Milan. Evaluation of socioeconomic and healthcare data collected by the mobile unit of Naga, a voluntary association based in Milan, during two years of activity (2009-2010). Healthcare data have been classified using an operational classification. Settlements located in Milan where rom a people live. 1 142 rom a people living in 14 settlements of Milan (only one authorized) were visited.Mean schooling years were 4.9. The mean number of children per family was 2.8. Of 803 people older than 13 years, 129 had an occupation (16%). 56%of subjetcs older than 12 years were smokers (53% females vs. 59%males); among smokers, 17%were heavy smokers (12%females vs 22% males). The most frequently reported diseases were: respiratory diseases (21%of total diagnoses), disorders of the orthopedic-rheumatologic-traumatology area (13%), gastroenterological diseases (10%) and dental problems (8%). Most residents had no healthcare coverage (94%). Almost all settlements (except the authorized one) had no sanitary facilities, no garbage collection system and were definitely overcrowded. Mild diseases were the most commonly found pathologies, with few chronic diseases reported probably due to difficulties in investigating more complex diseases in the study setting,and to the impossibility to follow the patients over time. Furthermore, the access to healthcare services for diagnostic tests and specialist visits is very very difficult for these patients. Poor living conditions, low educational level, low employment rate, barriers in the access to healthcare services are all risks factors for the health status of rom a people.

  16. Differences in active range of motion measurements in the upper extremity of patients with writer's cramp compared with healthy controls.

    PubMed

    Srivanitchapoom, Prachaya; Shamim, Ejaz A; Diomi, Pierre; Hattori, Takaaki; Pandey, Sanjay; Vorbach, Sherry; Park, Jung E; Wu, Tianxia; Auh, Sungyoung; Hallett, Mark

    Exploratory case-control study. Writer's cramp (WC) is a type of focal hand dystonia. The central nervous system plays a role in its pathophysiology, but abnormalities in the affected musculoskeletal components may also be relevant. We compared the active range of motion (ROM) in patients with WC and healthy volunteers (HVs) and correlated the findings with disease duration and severity. Affected limb joints were measured with goniometers. Patients were assessed at least 3 months after their last botulinum toxin (botulinum neurotoxin) injection, and strength was clinically normal. t tests were used to compare the ROMs of WC with matched HVs. The Spearman correlation coefficient assessed the relationship of active ROMs to the disease duration and handwriting subscore of the Dystonia Disability Scale. ROMs of D1 metacarpophalangeal (MCP) joint extension as well as D2 and D5 MCP flexion were significantly smaller in WC, and distal interphalangeal joint extension in D3 and D5 was significantly greater compared with HVs. There were negative correlations between D2 MCP flexion and disease duration and with Dystonia Disability Scale. Abnormalities in ROMs in WC were found. Severity and disease duration correlated with reduced D2 MCP flexion. This may be related to intrinsic biomechanical abnormalities, co-contraction of muscles, or a combination of subclinical weakness and atrophy from repeated botulinum neurotoxin injections. Hand biomechanical properties should not be ignored in the pathophysiology of WC. 2c. Copyright © 2016 Hanley & Belfus. All rights reserved.

  17. Improvements in hip flexibility do not transfer to mobility in functional movement patterns.

    PubMed

    Moreside, Janice M; McGill, Stuart M

    2013-10-01

    The purpose of this study was to analyze the transference of increased passive hip range of motion (ROM) and core endurance to functional movement. Twenty-four healthy young men with limited hip mobility were randomly assigned to 4 intervention groups: group 1, stretching; group 2, stretching plus hip/spine disassociation exercises; group 3, core endurance; and group 4, control. Previous work has documented the large increase in passive ROM and core endurance that was attained over the 6-week interventions, but whether these changes transferred to functional activities was unclear. Four dynamic activities were analyzed before and after the 6-week interventions: active standing hip extension, lunge, a standing twist/reach maneuver, and exercising on an elliptical trainer. A Vicon motion capture system collected body segment kinematics, with hip and lumbar spine angles subsequently calculated in Visual 3D. Repeated measures analyses of variance determined group effects on various hip and spine angles, with paired t-tests on specific pre/post pairs. Despite the large increases in passive hip ROM, there was no evidence of increased hip ROM used during functional movement testing. Similarly, the only significant change in lumbar motion was a reduction in lumbar rotation during the active hip extension maneuver (p < 0.05). These results indicate that changes in passive ROM or core endurance do not automatically transfer to changes in functional movement patterns. This implies that training and rehabilitation programs may benefit from an additional focus on 'grooving' new motor patterns if newfound movement range is to be used.

  18. Symmetrical kinematics does not imply symmetrical kinetics in people with transtibial amputation using cycling model.

    PubMed

    Childers, W Lee; Kogler, Géza F

    2014-01-01

    People with amputation move asymmetrically with regard to kinematics (joint angles) and kinetics (joint forces and moments). Clinicians have traditionally sought to minimize kinematic asymmetries, assuming kinetic asymmetries would also be minimized. A cycling model evaluated locomotor asymmetries. Eight individuals with unilateral transtibial amputation pedaled with 172 mm-length crank arms on both sides (control condition) and with the crank arm length shortened to 162 mm on the amputated side (CRANK condition). Pedaling kinetics and limb kinematics were recorded. Joint kinetics, joint angles (mean and range of motion [ROM]), and pedaling asymmetries were calculated from force pedals and with a motion capture system. A one-way analysis of variance with tukey post hoc compared kinetics and kinematics across limbs. Statistical significance was set to p

  19. A Correlative Study of CD-ROM Picture Books in Classrooms and School Children's Formation of Descriptive Concepts

    ERIC Educational Resources Information Center

    Lu, Chow-Chin; Chen, Yueh-Yun; Chen, Chen-Wei

    2011-01-01

    The central focus of this study was the development, use and evaluation of CD-ROM picture books in elementary school science teaching. Three CD-ROM picture books based on the Campus Insects unit from the new elementary school science curriculum in Taiwan were developed. A quasi-experimental method was used to compare the use of the CD-ROMs and…

  20. The effects of a human patient simulator vs. a CD-ROM on performance.

    PubMed

    Johnson, Don; Corrigan, Theresa; Gulickson, Gary; Holshouser, Elizabeth; Johnson, Sabine

    2012-10-01

    Military health care personnel need to have skills relative to caring for patients on the battlefield. No studies have compared the two teaching strategies of using the human patient simulator (HPS) and a CD-ROM in caring for combat injuries. The objective of this study was to determine if there were statistically significant differences in HPS and CD-ROM educational strategies relative to caring for patients who have trauma. A pretest/post-test prospective experimental design was used. Anesthesia students were randomly assigned to one of three groups: HPS, CD-ROM, or a control group. A valid and reliable instrument, Combat Performance, was used to evaluate the participant's ability to give care to trauma patients. A repeated analysis of variance and a least significant difference post hoc test were used to analyze the data. The HPS group performed better than the CD-ROM and control groups relative to performance (p = 0.001). There was no difference between the CD-ROM and control group (p = 0.171). We speculate that the HPS group performed better than the CD-ROM group because of the realism. In this study, the HPS method of instruction was a more effective method of teaching than the CD-ROM approach.

  1. Influence of Playing a Prolonged Tennis Match on Shoulder Internal Range of Motion.

    PubMed

    Martin, Caroline; Kulpa, Richard; Ezanno, Felix; Delamarche, Paul; Bideau, Benoit

    2016-08-01

    Shoulder range of motion (ROM) deficits have been identified as an injury risk factor among tennis players. It is well known that shoulder internal rotation deficit increases with age and years of play, but there is a lack of knowledge regarding the influence of a prolonged tennis match on shoulder ROM. To examine changes in shoulder ROM during a prolonged tennis match. Descriptive laboratory study. Shoulder passive internal and external rotation ROM were measured on 8 male tennis players before, every 30 minutes during, and just after a 3-hour tennis match. Total ROM was calculated as the combination of shoulder internal and external rotations. Ball velocity on the serve was measured with a radar gun before, at midmatch, and just after the match. Decreases in shoulder internal rotation (-20.8°; P = .005), total ROM (-24.6°; P = .001), and serve velocity (-1.8 m/s; P = .002) were observed at the end of the match. No statistically significant difference was observed for shoulder external rotation after the match (P = .460). Passive shoulder internal rotation and total ROM are significantly decreased during a 3-hour tennis match. The results show that a prolonged tennis match play can modify values of shoulder ROM. © 2016 The Author(s).

  2. Development of a three-dimensional, regional, coupled wave, current, and sediment-transport model

    USGS Publications Warehouse

    Warner, J.C.; Sherwood, C.R.; Signell, R.P.; Harris, C.K.; Arango, H.G.

    2008-01-01

    We are developing a three-dimensional numerical model that implements algorithms for sediment transport and evolution of bottom morphology in the coastal-circulation model Regional Ocean Modeling System (ROMS v3.0), and provides a two-way link between ROMS and the wave model Simulating Waves in the Nearshore (SWAN) via the Model-Coupling Toolkit. The coupled model is applicable for fluvial, estuarine, shelf, and nearshore (surfzone) environments. Three-dimensional radiation-stress terms have been included in the momentum equations, along with effects of a surface wave roller model. The sediment-transport algorithms are implemented for an unlimited number of user-defined non-cohesive sediment classes. Each class has attributes of grain diameter, density, settling velocity, critical stress threshold for erosion, and erodibility constant. Suspended-sediment transport in the water column is computed with the same advection-diffusion algorithm used for all passive tracers and an additional algorithm for vertical settling that is not limited by the CFL criterion. Erosion and deposition are based on flux formulations. A multi-level bed framework tracks the distribution of every size class in each layer and stores bulk properties including layer thickness, porosity, and mass, allowing computation of bed morphology and stratigraphy. Also tracked are bed-surface properties including active-layer thickness, ripple geometry, and bed roughness. Bedload transport is calculated for mobile sediment classes in the top layer. Bottom-boundary layer submodels parameterize wave-current interactions that enhance bottom stresses and thereby facilitate sediment transport and increase bottom drag, creating a feedback to the circulation. The model is demonstrated in a series of simple test cases and a realistic application in Massachusetts Bay. 

  3. Development of a General Conceptual-numerical Model to Simulate the Fate and Subsurface Transport of Explosives, and the Moisture and Temperature Signatures Around Land Mines

    DTIC Science & Technology

    2008-12-01

    Šimůnek, J. W. Hopmans, and A. Tuli , Numerical evaluation of the heat pulse probe for simultaneous estimation of water fluxes and soil hydraulic and...America annual meeting, Agronomy Abstracts, published on a CD-ROM as abstract 132-2, ASA, Madison, 2006. Saito, H., J. Šimunek, A. Tuli and J. W...Abstracts, published on a CD-ROM as abstract 183-8, ASA, Madison, 2007. Tuli , A., T. Kamai, H. Saito, J. Hopmans, and J. Šimunek, Experimental and

  4. Atmosphere-ocean feedbacks in a coastal upwelling system

    NASA Astrophysics Data System (ADS)

    Alves, J. M. R.; Peliz, A.; Caldeira, R. M. A.; Miranda, P. M. A.

    2018-03-01

    The COAWST (Coupled Ocean-Atmosphere-Wave-Sediment Transport) modelling system is used in different configurations to simulate the Iberian upwelling during the 2012 summer, aiming to assess the atmosphere-ocean feedbacks in the upwelling dynamics. When model results are compared with satellite measurements and in-situ data, two-way coupling is found to have a moderate impact in data-model statistics. A significant reinforcement of atmosphere-ocean coupling coefficients is, however, observed in the two-way coupled run, and in the WRF and ROMS runs forced by previously simulated SST and wind fields, respectively. The increasing in the coupling coefficient is associated with slight, but potentially important changes in the low-level coastal jet in the atmospheric marine boundary layer. While these results do not imply the need for fully coupled simulations in many applications, they show that in seasonal numerical studies such simulations do not degrade the overall model performance, and contribute to produce better dynamical fields.

  5. Using wind setdown and storm surge on Lake Erie to calibrate the air-sea drag coefficient.

    PubMed

    Drews, Carl

    2013-01-01

    The air-sea drag coefficient controls the transfer of momentum from wind to water. In modeling storm surge, this coefficient is a crucial parameter for estimating the surge height. This study uses two strong wind events on Lake Erie to calibrate the drag coefficient using the Coupled Ocean Atmosphere Wave Sediment Transport (COAWST) modeling system and the the Regional Ocean Modeling System (ROMS). Simulated waves are generated on the lake with Simulating WAves Nearshore (SWAN). Wind setdown provides the opportunity to eliminate wave setup as a contributing factor, since waves are minimal at the upwind shore. The study finds that model results significantly underestimate wind setdown and storm surge when a typical open-ocean formulation without waves is used for the drag coefficient. The contribution of waves to wind setdown and storm surge is 34.7%. Scattered lake ice also increases the effective drag coefficient by a factor of 1.1.

  6. Eating increases oxidative damage in a reptile.

    PubMed

    Butler, Michael W; Lutz, Thomas J; Fokidis, H Bobby; Stahlschmidt, Zachary R

    2016-07-01

    While eating has substantial benefits in terms of both nutrient and energy acquisition, there are physiological costs associated with digesting and metabolizing a meal. Frequently, these costs have been documented in the context of energy expenditure while other physiological costs have been relatively unexplored. Here, we tested whether the seemingly innocuous act of eating affects either systemic pro-oxidant (reactive oxygen metabolite, ROM) levels or antioxidant capacity of corn snakes (Pantherophis guttatus) by collecting plasma during absorptive (peak increase in metabolic rate due to digestion of a meal) and non-absorptive (baseline) states. When individuals were digesting a meal, there was a minimal increase in antioxidant capacity relative to baseline (4%), but a substantial increase in ROMs (nearly 155%), even when controlling for circulating nutrient levels. We report an oxidative cost of eating that is much greater than that due to long distance flight or mounting an immune response in other taxa. This result demonstrates the importance of investigating non-energetic costs associated with meal processing, and it begs future work to identify the mechanism(s) driving this increase in ROM levels. Because energetic costs associated with eating are taxonomically widespread, identifying the taxonomic breadth of eating-induced ROM increases may provide insights into the interplay between oxidative damage and life history theory. © 2016. Published by The Company of Biologists Ltd.

  7. Effects of Wheelchair Seat-height Settings on Alternating Lower Limb Propulsion With Both Legs.

    PubMed

    Murata, Tomoyuki; Asami, Toyoko; Matsuo, Kiyomi; Kubo, Atsuko; Okigawa, Etsumi

    2014-01-01

    This study investigated the effects of seat-height settings of wheelchairs with alternating propulsion with both legs. Seven healthy individuals with no orthopedic disease participated. Flexion angles at initial contact (FA-IC) of each joint, range of motion during propulsion period (ROM-PP), and ground reaction force (GRF) were measured using a three dimensional motion capture system and force plates, and compared with different seat-height settings. Statistically significant relationships were found between seat-height and speed, stride length, knee FA-IC, ankle FA-IC, hip ROM-PP, vertical ground reaction force (VGRF), and anterior posterior ground reaction force (APGRF). Speed, hip ROM-PP, VGRF and APGRF increased as the seat-height was lowered. This effect diminished when the seat-height was set below -40 mm. VGRF increased as the seat-height was lowered. The results suggest that the seat-height effect can be attributed to hip ROM-PP; therefore, optimal foot propulsion cannot be achieved when the seat height is set either too high or too low. Efficient foot propulsion of the wheelchair can be achieved by setting the seat height to lower leg length according to a combination of physical characteristics, such as the user's physical functions, leg muscles, and range of motion.

  8. The influence of water depth on kinematic and spatiotemporal gait parameters during aquatic treadmill walking.

    PubMed

    Jung, Taeyou; Kim, Yumi; Lim, Hyosok; Vrongistinos, Konstantinos

    2018-01-16

    The purpose of this study was to investigate kinematic and spatiotemporal variables of aquatic treadmill walking at three different water depths. A total of 15 healthy individuals completed three two-minute walking trials at three different water depths. The aquatic treadmill walking was conducted at waist-depth, chest-depth and neck-depth, while a customised 3-D underwater motion analysis system captured their walking. Each participant's self-selected walking speed at the waist level was used as a reference speed, which was applied to the remaining two test conditions. A repeated measures ANOVA showed statistically significant differences among the three walking conditions in stride length, cadence, peak hip extension, hip range of motion (ROM), peak ankle plantar flexion and ankle ROM (All p values < 0.05). The participants walked with increased stride length and decreased cadence during neck level as compared to waist and chest level. They also showed increased ankle ROM and decreased hip ROM as the water depth rose from waist and chest to the neck level. However, our study found no significant difference between waist and chest level water in all variables. Hydrodynamics, such as buoyancy and drag force, in response to changes in water depths, can affect gait patterns during aquatic treadmill walking.

  9. The direct analysis of drug distribution of rotigotine-loaded microspheres from tissue sections by LESA coupled with tandem mass spectrometry.

    PubMed

    Xu, Li-Xiao; Wang, Tian-Tian; Geng, Yin-Yin; Wang, Wen-Yan; Li, Yin; Duan, Xiao-Kun; Xu, Bin; Liu, Charles C; Liu, Wan-Hui

    2017-09-01

    The direct analysis of drug distribution of rotigotine-loaded microspheres (RoMS) from tissue sections by liquid extraction surface analysis (LESA) coupled with tandem mass spectrometry (MS/MS) was demonstrated. The RoMS distribution in rat tissues assessed by the ambient LESA-MS/MS approach without extensive or tedious sample pretreatment was compared with that obtained by a conventional liquid chromatography tandem mass spectrometry (LC-MS/MS) method in which organ excision and subsequent solvent extraction were commonly employed before analysis. Results obtained from the two were well correlated for a majority of the organs, such as muscle, liver, stomach, and hippocampus. The distribution of RoMS in the brain, however, was found to be mainly focused in the hippocampus and striatum regions as shown by the LESA-imaged profiles. The LESA approach we developed is sensitive enough, with an estimated LLOQ at 0.05 ng/mL of rotigotine in brain tissue, and information-rich with minimal sample preparation, suitable, and promising in assisting the development of new drug delivery systems for controlled drug release and protection. Graphical abstract Workflow for the LESA-MS/MS imaging of brain tissue section after intramuscular RoMS administration.

  10. Public census data on CD-ROM at Lawrence Berkeley Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrill, D.W.

    The Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socio-economic and geographic data files which are available to CEDR and PAREP collaborators via LBL`s computing network. At this time 70 CD-ROM diskettes (approximately 36 gigabytes) are on line via the Unix file server cedrcd. lbl. gov. Most of the files are from the US Bureau of the Census, and most pertain to the 1990 Census of Population and Housing. All the CD-ROM diskettes contain documentation in the formmore » of ASCII text files. Printed documentation for most files is available for inspection at University of California Data and Technical Assistance (UC DATA), or the UC Documents Library. Many of the CD-ROM diskettes distributed by the Census Bureau contain software for PC compatible computers, for easily accessing the data. Shared access to the data is maintained through a collaboration among the CEDR and PAREP projects at LBL, and UC DATA, and the UC Documents Library. Via the Sun Network File System (NFS), these data can be exported to Internet computers for direct access by the user`s application program(s).« less

  11. Public census data on CD-ROM at Lawrence Berkeley Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrill, D.W.

    The Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socio-economic and geographic data files which are available to CEDR and PAREP collaborators via LBL's computing network. At this time 70 CD-ROM diskettes (approximately 36 gigabytes) are on line via the Unix file server cedrcd. lbl. gov. Most of the files are from the US Bureau of the Census, and most pertain to the 1990 Census of Population and Housing. All the CD-ROM diskettes contain documentation in the formmore » of ASCII text files. Printed documentation for most files is available for inspection at University of California Data and Technical Assistance (UC DATA), or the UC Documents Library. Many of the CD-ROM diskettes distributed by the Census Bureau contain software for PC compatible computers, for easily accessing the data. Shared access to the data is maintained through a collaboration among the CEDR and PAREP projects at LBL, and UC DATA, and the UC Documents Library. Via the Sun Network File System (NFS), these data can be exported to Internet computers for direct access by the user's application program(s).« less

  12. BOREAS RSS-14 Level-1 GOES-8 Visible, IR and Water Vapor Images

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Faysash, David; Cooper, Harry J.; Smith, Eric A.; Newcomer, Jeffrey A.

    2000-01-01

    The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. The level-1 BOREAS GOES-8 images are raw data values collected by RSS-14 personnel at FSU and delivered to BORIS. The data cover 14-Jul-1995 to 21-Sep-1995 and 01-Jan-1996 to 03-Oct-1996. The data start out containing three 8-bit spectral bands and end up containing five 10-bit spectral bands. No major problems with the data have been identified. The data are contained in binary image format files. Due to the large size of the images, the level-1 GOES-8 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1 GOES-8 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).

  13. BOREAS RSS-14 Level 1a GOES-7 Visible, IR, and Water Vapor Images

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Newcomer, Jeffrey A.; Faysash, David; Cooper, Harry J.; Smith, Eric A.

    2000-01-01

    The BOREAS RSS-14 team collected and processed GOES-7 and -8 images of the BOREAS region as part of its effort to characterize the incoming, reflected, and emitted radiation at regional scales. The level-1a BOREAS GOES-7 image data were collected by RSS-14 personnel at FSU and processed to level-1a products by BORIS personnel. The data cover the period of 01-Jan-1994 through 08-Jul-1995 with partial to complete coverage on the majority of the days. The data include three bands with eightbit pixel values. No major problems with the data have been identified. Due to the large size of the images, the level-1a GOES-7 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1a GOES-7 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).

  14. BOREAS RSS-14 Level-1 GOES-7 Visible, IR and Water Vapor Images

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Faysash, David; Cooper, Harry J.; Smith, Eric A.; Newcomer, Jeffrey A.

    2000-01-01

    The BOREAS RSS-14 team collected and processed GOES-7 and -8 images of the BOREAS region as part of its effort to characterize the incoming, reflected, and emitted radiation at regional scales. The level-1 BOREAS GOES-7 image data were collected by RSS-14 personnel at FSU and delivered to BORIS. The data cover the period of 01-Jan-1994 through 08-Jul-1995, with partial to complete coverage on the majority of the days. The data include three bands with eight-bit pixel values. No major problems with the data have been identified. Due to the large size of the images, the level-1 GOES-7 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1 GOES-7 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).

  15. Measurement of body joint angles for physical therapy based on mean shift tracking using two low cost Kinect images.

    PubMed

    Chen, Y C; Lee, H J; Lin, K H

    2015-08-01

    Range of motion (ROM) is commonly used to assess a patient's joint function in physical therapy. Because motion capture systems are generally very expensive, physical therapists mostly use simple rulers to measure patients' joint angles in clinical diagnosis, which will suffer from low accuracy, low reliability, and subjective. In this study we used color and depth image feature from two sets of low-cost Microsoft Kinect to reconstruct 3D joint positions, and then calculate moveable joint angles to assess the ROM. A Gaussian background model is first used to segment the human body from the depth images. The 3D coordinates of the joints are reconstructed from both color and depth images. To track the location of joints throughout the sequence more precisely, we adopt the mean shift algorithm to find out the center of voxels upon the joints. The two sets of Kinect are placed three meters away from each other and facing to the subject. The joint moveable angles and the motion data are calculated from the position of joints frame by frame. To verify the results of our system, we take the results from a motion capture system called VICON as golden standard. Our 150 test results showed that the deviation of joint moveable angles between those obtained by VICON and our system is about 4 to 8 degree in six different upper limb exercises, which are acceptable in clinical environment.

  16. Age and sex differences in ranges of motion and motion patterns.

    PubMed

    Hwang, Jaejin; Jung, Myung-Chul

    2015-01-01

    This study investigated the effects of age and sex on joint ranges of motion (ROMs) and motion patterns. Forty participants performed 18 motions using eight body segments at self-selected speeds. Older subjects showed smaller ROMs than younger subjects for 11 motions; the greatest difference in ROM was 44.9% for eversion/inversion of the foot. Older subjects also required more time than younger subjects to approach the peak angular velocity for six motions. In contrast, sex significantly affected ROMs but not motion patterns. Male subjects exhibited smaller ROMs than female subjects for four motions; the greatest sex-dependent difference in ROM was 29.7% for ulnar/radial deviation of the hand. The age and sex effects depended on the specific segments used and motions performed, possibly because of differences in anatomical structures and frequencies of use of the joints in habitual physical activities between the groups.

  17. Development and Evaluation of a Multimedia CD-ROM for Exercise During Pregnancy and Postpartum

    PubMed Central

    Hausenblas, Heather A.; Brewer, Britton W.; Van Raalte, Judy L.; Cook, Brian; Downs, Danielle Symons; Weis, Carol Ann; Nigg, Claudio; Cruz, Amelia

    2008-01-01

    Objective To meet the need for an interactive product on exercise during pregnancy and postpartum, we developed and evaluated a personally-tailored multimedia CD-ROM. Methods Pregnant and postpartum women, who were randomly assigned to either the experimental group (PregXercise™ CD-ROM) or the control group (CD-ROM with neutral content), navigated through the CD-ROM for 1 hour. Main outcomes were exercise self-efficacy and knowledge. Results In analyses of covariance, compared with the control group, the experimental group had significant increases in self-efficacy and knowledge. Conclusion The multimedia CD-ROM delivering information about exercise motivation, guidelines, and prescription was effective in improving exercise self-efficacy and knowledge. Practice Implications Our preliminary results illustrate that healthcare professionals and researchers may use interactive multimedia for improving exercise behavior and related outcomes with pregnant and postpartum women. PMID:18068940

  18. Minutes of the CD-ROM Workshop

    NASA Technical Reports Server (NTRS)

    King, Joseph H.; Grayzeck, Edwin J.

    1989-01-01

    The workshop described in this document had two goals: (1) to establish guidelines for the CD-ROM as a tool to distribute datasets; and (2) to evaluate current scientific CD-ROM projects as an archive. Workshop attendees were urged to coordinate with European groups to develop CD-ROM, which is already available at low cost in the U.S., as a distribution medium for astronomical datasets. It was noted that NASA has made the CD Publisher at the National Space Science Data Center (NSSDC) available to the scientific community when the Publisher is not needed for NASA work. NSSDC's goal is to provide the Publisher's user with the hardware and software tools needed to design a user's dataset for distribution. This includes producing a master CD and copies. The prerequisite premastering process is described, as well as guidelines for CD-ROM construction. The production of discs was evaluated. CD-ROM projects, guidelines, and problems of the technology were discussed.

  19. Conversion of IVA Human Computer Model to EVA Use and Evaluation and Comparison of the Result to Existing EVA Models

    NASA Technical Reports Server (NTRS)

    Hamilton, George S.; Williams, Jermaine C.

    1998-01-01

    This paper describes the methods, rationale, and comparative results of the conversion of an intravehicular (IVA) 3D human computer model (HCM) to extravehicular (EVA) use and compares the converted model to an existing model on another computer platform. The task of accurately modeling a spacesuited human figure in software is daunting: the suit restricts the human's joint range of motion (ROM) and does not have joints collocated with human joints. The modeling of the variety of materials needed to construct a space suit (e. g. metal bearings, rigid fiberglass torso, flexible cloth limbs and rubber coated gloves) attached to a human figure is currently out of reach of desktop computer hardware and software. Therefore a simplified approach was taken. The HCM's body parts were enlarged and the joint ROM was restricted to match the existing spacesuit model. This basic approach could be used to model other restrictive environments in industry such as chemical or fire protective clothing. In summary, the approach provides a moderate fidelity, usable tool which will run on current notebook computers.

  20. Effects of seasonal variability in across- and alongshore transport of anchoveta ( Engraulis ringens) larvae on model-based pre-recruitment indices off central Chile

    NASA Astrophysics Data System (ADS)

    Parada, Carolina; Colas, Francois; Soto-Mendoza, Samuel; Castro, Leonardo

    2012-01-01

    An individual-based model (IBM) of anchoveta ( Engraulis ringens) larvae was coupled to a climatological hydrodynamic (Regional Oceanic Modeling System, ROMS) model for central-southern Chile to answer the question as to whether or not across- and alongshore transport off central-southern Chile enhances retention in the spawning areas during the winter and summer reproductive periods, using model-based pre-recruitment indices (simulated transport success to nursery areas). The hydrodynamic model validation showed that ROMS captures the mean Seas Surface Temperature and Eddie Kinetic Energy observed in satellite-based data over the entire region. The IBM was used to simulate the transport of eggs and larvae from spawning zones in central Chile (Constitución, Dichato, Gulf of Arauco and Lebu-Corral) to historical nursery areas (HRZ, region between 35°S and 37°S). Model results corroborated HRZ as the most successful pre-recruitment zone (particles originated in the Dichato and Gulf of Arauco spawning areas), as well as identifying Lebu-Corral as a zone of high retention with a high associated pre-recruitment index (particles originated in the Lebu-Corral spawning zone). The highest pre-recruitment values were mainly found in winter. The Constitución and Dichato spawning zones displayed a typical summer upwelling velocity pattern, while the Gulf of Arauco in summertime showed strong offshore and alongshore velocity components. The Lebu-Corral region in winter presented important near-surface cross-shore transport towards the coast (associated with downwelling events), this might be one of the major mechanisms leading to high retention levels and a high pre-recruitment index for Lebu-Corral spawning zone. The limitations of the modeling approach are discussed and put into perspective for future work.

  1. Improving in the fasting, but not the postprandial, glucose level is associated with reduction of plasma d-ROMs level in patients with type 2 diabetes.

    PubMed

    Ohara, Makoto; Watanabe, Kentaro; Suzuki, Tatsuya; Sekimizu, Ken-ichi; Motoyama, Masayuki; Ishii, Kazuhito; Sawai, Keisuke; Nakano, Hiroshi; Oba, Kenzo; Mizuno, Kyoichi

    2013-01-01

    This study aimed to evaluate the relationship between improvement of glucose metabolism and plasma levels of diacron-reactive oxygen metabolites (d-ROMs) in patients with type 2 diabetes. As the first daily profile, the plasma levels of glucose and d-ROMs were determined on admission. Then, after treatment to lower plasma glucose levels, the second daily profile of these levels was evaluated. Fasting plasma glucose (FPG), the total area under the curve (AUC) of the daily plasma glucose profile (AUCDP), the AUC of the postprandial plasma glucose levels (AUCPP), the AUC of the daily plasma d-ROMs profile (AUCd-ROMs), the coefficient of variation (CV) of plasma glucose (CVPG), and the mean amplitude of glycemic excursions (MAGE) were calculated. The relationship between the improvement of glucose metabolism and that of oxidative stress in patients with type 2 diabetes was evaluated. The second determinations of FPG, AUCDP, AUCPP, MAGE, and AUCd-ROMs were significantly lower than those of the first determinations, but no significant difference was observed in CVPG. Linear regression analysis demonstrated significant associations between the changes in AUCd-ROMs and the changes in both FPG and AUCDP, whereas no significant association was observed between the change in AUCd-ROMs and the change in AUCPP, CVPG, or MAGE. This study has demonstrated that improvement of the FPG level, but not of the postprandial glucose level, is associated with a reduction of the plasma level of d-ROMs in patients with type 2 diabetes.

  2. CD-ROMs review 1995-1997: a multicentre pilot trial.

    PubMed

    Grey-Lloyd, J

    1998-03-01

    This article describes an evaluation of CD-ROMs carried out at four NHS Trust Libraries in Wales. It covers interactive CD-ROMs which take the form of either computer assisted learning programs, encyclopaedia or well-known text books.

  3. Mechanisms of Shoulder Range of Motion Deficits in Asymptomatic Baseball Players.

    PubMed

    Bailey, Lane B; Shanley, Ellen; Hawkins, Richard; Beattie, Paul F; Fritz, Stacy; Kwartowitz, David; Thigpen, Charles A

    2015-11-01

    Shoulder range of motion (ROM) deficits have been identified as injury risk factors among baseball athletes. Despite the knowledge surrounding these risk factors, there is a lack of consensus regarding the specific tissues responsible for these deficits in ROM. The purpose of this study was to elucidate the primary mechanisms of posterior shoulder tightness (capsular, musculotendinous, bony) by examining the tissue responses that occur with the application of an acute intervention in baseball players with ROM deficits. The hypothesis was that posterior rotator cuff stiffness, not glenohumeral joint mobility, would be primarily responsible for ROM gains observed within an acute treatment setting. Controlled laboratory study. Through use of ultrasound elastography, electromagnetic motion analysis, and ultrasound imaging, posterior rotator cuff stiffness, glenohumeral joint translation, and humeral torsion were examined in 60 asymptomatic baseball players (age, mean ± SD, 19 ± 2 years) with shoulder ROM deficits. Tissue mechanisms were examined concurrently, with the ROM gains elicited by an acute application of instrument-assisted soft tissue mobilization plus self-stretching (n = 30) versus self-stretching only (n = 30). Separate 3-way analyses of variance (group × arm × time) and linear regression analyses were used to determine the treatment effects and relationships between tissue mechanisms and ROM gains. ROM gains were associated with decreases in rotator cuff stiffness (internal rotation: r = 0.35, P = .034; horizontal adduction: r = 0.44, P = .008) and increased humeral retrotorsion (internal rotation: r = -0.35, P = .034), not joint translation (P > .05). Players receiving instrument-assisted soft tissue mobilization plus stretching displayed greater shoulder ROM gains (internal rotation, +5° ± 2° [P = .010]; total arc of motion, +8° ± 6° [P = .010]; horizontal adduction, +7° ± 2° [P = .004]; and decreased posterior rotator cuff stiffness, -0.2 ± 0.3 kPa [P = .050]) compared with players receiving self-stretching alone. Decreases in rotator cuff stiffness were associated with acute ROM gains in baseball players. The study results show that changes in rotator cuff stiffness, not glenohumeral joint mobility or humeral torsion, are most likely associated with the ROM deficits observed in adolescent baseball players. Reducing rotator cuff stiffness may be beneficial in improving the ROM deficits associated with injury risk in overhead athletes. © 2015 The Author(s).

  4. Pronation-Supination Motion Is Altered in a Rat Model of Post-Traumatic Elbow Contracture.

    PubMed

    Dunham, Chelsey L; Castile, Ryan M; Chamberlain, Aaron M; Galatz, Leesa M; Lake, Spencer P

    2017-07-01

    The elbow joint is highly susceptible to joint contracture, and treating elbow contracture is a challenging clinical problem. Previously, we established an animal model to study elbow contracture that exhibited features similar to the human condition including persistent decreased range of motion (ROM) in flexion-extension and increased capsule thickness/adhesions. The objective of this study was to mechanically quantify pronation-supination in different injury models to determine if significant differences compared to control or contralateral persist long-term in our animal elbow contracture model. After surgically inducing soft tissue damage in the elbow, Injury I (anterior capsulotomy) and Injury II (anterior capsulotomy with lateral collateral ligament transection), limbs were immobilized for 6 weeks (immobilization (IM)). Animals were evaluated after the IM period or following an additional 6 weeks of free mobilization (FM). Total ROM for pronation-supination was significantly decreased compared to the uninjured contralateral limb for both IM and FM, although not different from control limbs. Specifically, for both IM and FM, total ROM for Injury I and Injury II was significantly decreased by ∼20% compared to contralateral. Correlations of measurements from flexion-extension and pronation-supination divulged that FM did not affect these motions in the same way, demonstrating that joint motions need to be studied/treated separately. Overall, injured limbs exhibited persistent motion loss in pronation-supination when comparing side-to-side differences, similar to human post-traumatic joint contracture. Future work will use this animal model to study how elbow periarticular soft tissues contribute to contracture.

  5. Centralization of symptoms and lumbar range of motion in patients with low back pain.

    PubMed

    Bybee, Ronald F; Olsen, Denise L; Cantu-Boncser, Gloria; Allen, Heather Condie; Byars, Allyn

    2009-05-01

    This quasi-experimental repeated measures study examined the relationship between centralization of symptoms and lumbar flexion and extension range of motion (ROM) in patients with low back pain. Rapid and lasting changes in lumbar ROM have been noted with centralization of symptoms. However, no study has objectively measured the changes in lumbar ROM occurring with centralization. Forty-two adult subjects (mean age, 45.68 years; SD=15.76 years) with low back pain and associated lower extremity symptoms were followed by McKenzie trained physical therapists. Subjects' lumbar ROM was measured at the beginning and end of each patient visit by using double inclinometers, and pain location was documented. Subjects were grouped as 1) centralized, 2) centralizing, or 3) noncentralized for comparisons of symptom and ROM changes. Data were analyzed by using multivariate analysis of variance and one-way analysis of variance. Significance was set at 0.05. A significant difference was found between initial and final mean extension ROM in the centralized and centralizing groups (p=0.003). No significant difference was found in the noncentralized group (p<0.05). Subjects (n=23) who demonstrated a change in pain location during the initial visit also showed a significant (p<0.001) change in extension ROM, whereas patients with no change in pain location (n=19) did not (p=0.848). Lumbar extension ROM increased as centralization occurred.

  6. Self-Myofascial Release: No Improvement of Functional Outcomes in 'Tight' Hamstrings.

    PubMed

    Morton, Robert W; Oikawa, Sara Y; Phillips, Stuart M; Devries, Michaela C; Mitchell, Cameron J

    2016-07-01

    Self-myofascial release (SMR) is a common exercise and therapeutic modality shown to induce acute improvements in joint range of motion (ROM) and recovery; however, no long-term studies have been conducted. Static stretching (SS) is the most common method used to increase joint ROM and decrease muscle stiffness. It was hypothesized that SMR paired with SS (SMR+SS) compared with SS alone over a 4-wk intervention would yield greater improvement in knee-extension ROM and hamstring stiffness. 19 men (22 ± 3 y) with bilateral reduced hamstring ROM had each of their legs randomly assigned to either an SMR+SS or an SS-only group. The intervention consisted of 4 repetitions of SS each for 45 s or the identical amount of SS preceded by 4 repetitions of SMR each for 60 s and was performed on the respective leg twice daily for 4 wk. Passive ROM, hamstring stiffness, rate of torque development (RTD), and maximum voluntary contraction (MVC) were assessed pre- and postintervention. Passive ROM (P < .001), RTD, and MVC (P < .05) all increased after the intervention. Hamstring stiffness toward end-ROM was reduced postintervention (P = .02). There were no differences between the intervention groups for any variable. The addition of SMR to SS did not enhance the efficacy of SS alone. SS increases joint ROM through a combination of decreased muscle stiffness and increased stretch tolerance.

  7. Exploring the Potential Impact of Greenland Meltwater on Stratification, Photosynthetically Active Radiation, and Primary Production in the Labrador Sea

    NASA Astrophysics Data System (ADS)

    Oliver, Hilde; Luo, Hao; Castelao, Renato M.; van Dijken, Gert L.; Mattingly, Kyle S.; Rosen, Joshua J.; Mote, Thomas L.; Arrigo, Kevin R.; Rennermalm, Åsa K.; Tedesco, Marco; Yager, Patricia L.

    2018-04-01

    In July 2012, the surface of the Greenland Ice Sheet (GrIS) melted to an extent unprecedented over the last 100 years; we questioned the potential for such an extreme melt event to impact marine phytoplankton offshore. We hypothesized that stratification from meltwater could reduce light limitation for phytoplankton, and used a suite of numerical models to quantify the impact for 2003-2012. Because much of the 2012 meltwater discharged from southern Greenland, our study focused on the southwestern and southeastern coasts of Greenland, and the Labrador Sea. A 1-D phytoplankton model used output from a Regional Ocean Modeling System (ROMS) coupled with a Regional Climate Model and a hydrological model of meltwater from runoff sources on the ice sheet, peripheral glaciers, and tundra. ROMS was run with and without meltwater to test the sensitivity of phytoplankton photosynthetic rates to the meltwater input. With meltwater, the pycnocline was shallower during late summer and early fall and thus light limitation on photosynthesis was reduced. Averaged over all years, added meltwater had the potential to increase gross primary production by 3-12% in the summer (July-August), and 13-60% in the fall (September-October). This meltwater effect was amplified when light was more limiting, and thus was greatest in the fall, under cloudier conditions, with higher self-shading, and with more light-sensitive phytoplankton groups. As the GrIS melt is projected to increase, late summer primary production in this region has the potential to increase as well, which could constitute an important biosphere response to high-latitude climate change.

  8. Lumbar intervertebral disc allograft transplantation: long-term mobility and impact on the adjacent segments.

    PubMed

    Huang, Yong-Can; Xiao, Jun; Lu, William W; Leung, Victor Y L; Hu, Yong; Luk, Keith D K

    2017-03-01

    Fresh-frozen intervertebral disc (IVD) allograft transplantation has been successfully performed in the human cervical spine. Whether this non-fusion technology could truly decrease adjacent segment disease is still unknown. This study evaluated the long-term mobility of the IVD-transplanted segment and the impact on the adjacent spinal segments in a goat model. Twelve goats were used. IVD allograft transplantation was performed at lumbar L4/L5 in 5 goats; the other 7 goats were used as the untreated control (5) and for the supply of allografts (2). Post-operation lateral radiographs of the lumbar spine in the neutral, full-flexion and full-extension positions were taken at 1, 3, 6, 9 and 12 months. Disc height (DH) of the allograft and the adjacent levels was calculated and range of motion (ROM) was measured using the Cobb's method. The anatomy of the adjacent discs was observed histologically. DH of the transplanted segment was decreased significantly after 3 months but no further reduction was recorded until the final follow-up. No obvious alteration was seen in the ROM of the transplanted segment at different time points with the ROM at 12 months being comparable to that of the untreated control. The DH and ROM in the adjacent segments were well maintained during the whole observation period. At post-operative 12 months, the ROM of the adjacent levels was similar to that of the untreated control and the anatomical morphology was well preserved. Lumbar IVD allograft transplantation in goats could restore the segmental mobility and did not negatively affect the adjacent segments after 12 months.

  9. Protection of MPTP-induced neuroinflammation and neurodegeneration by rotigotine-loaded microspheres.

    PubMed

    Yu, Xin; Yao, Jun-Yi; He, Jie; Tian, Jing-Wei

    2015-03-01

    The aim of the study is to evaluate the neuroprotective effects of continuous dopaminergic stimulation (CDS) by rotigotine-loaded microspheres (RoMS) in a mouse model of MPTP-induced Parkinson's disease (PD) and to elucidate the potential mechanism underlying these effects. Male C57BL/6 mice were treated either intramuscularly once with RoMS or twice daily for two weeks with rotigotine, and from the 9th day, MPTP (30 mg/kg, i.p.) was injected for the last 5 days. Following treatment, Parkinsonism scores were calculated and oxidative stress-related indicators in the striatum were performed. Neuroinflammatory cytokines, such as tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), and interleukin-6 (IL-6) were detected in the striatum. Expression of apoptosis-related proteins B-cell leukemia/lymphoma 2 (Bcl-2) and Bcl-2-associated X protein (BAX) was measured in the striatum by Western blot. Nigral tyrosine hydroxylase (TH)-positive neurons and microglial cell markers, i.e., ionized calcium binding adaptor molecule-1 (Iba-1) and neuronal synaptosomes, were quantified to assess the neuroprotective efficacy of RoMS. The administration of rotigotine significantly improved the Parkinsonism score, protected dopaminergic neurons with antioxidants, reduced microglial cell activation and the release of neuroinflammatory cytokines, and balanced the expression of Bcl-2 and Bax in MPTP-treated mice. Interestingly, the neuroprotective properties of rotigotine were remarkably amplified by CDS treatment with RoMS. These results suggest that CDS therapy can play a neuroprotective role in an MPTP mouse model. Neuroprotective disease-modifying therapy may have the potential benefits of early treatment by normalizing compensatory mechanisms and may also help to delay dyskinesia in the later stages of PD. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Optimal allocation of bulk water supplies to competing use sectors based on economic criterion - An application to the Chao Phraya River Basin, Thailand

    NASA Astrophysics Data System (ADS)

    Divakar, L.; Babel, M. S.; Perret, S. R.; Gupta, A. Das

    2011-04-01

    SummaryThe study develops a model for optimal bulk allocations of limited available water based on an economic criterion to competing use sectors such as agriculture, domestic, industry and hydropower. The model comprises a reservoir operation module (ROM) and a water allocation module (WAM). ROM determines the amount of water available for allocation, which is used as an input to WAM with an objective function to maximize the net economic benefits of bulk allocations to different use sectors. The total net benefit functions for agriculture and hydropower sectors and the marginal net benefit from domestic and industrial sectors are established and are categorically taken as fixed in the present study. The developed model is applied to the Chao Phraya basin in Thailand. The case study results indicate that the WAM can improve net economic returns compared to the current water allocation practices.

  11. A Comparative Survey of Multimedia CD-ROM Encyclopedias.

    ERIC Educational Resources Information Center

    Clements, Jim; Nicholls, Paul

    1995-01-01

    Provides historical background information about multimedia CD-ROM encyclopedias and evaluates 11 recent releases. Discusses access to information, costs, content, technological developments. Rates the text, multimedia, and user interface. A sidebar provides a 10-year chronology of CD-ROM encyclopedias. (AEF)

  12. Diabetes Care in Republic of Macedonia: Challenges and Opportunities.

    PubMed

    Smokovski, Ivica; Milenkovic, Tatjana; Trapp, Caroline; Mitov, Aleksandar

    2015-01-01

    The Republic of Macedonia (RoM) has experienced a rapid rise in the prevalence of type 2 diabetes (T2D) over the past 2 decades, a period characterized by significant social, political, and economic change. RoM now has one of the highest rates of diabetes in Europe. To explore the modifiable conditions that may underlie and exacerbate the T2D epidemic; describe the state of diabetes care; and consider improved mechanisms for prevention and treatment, including research priorities, in RoM. Methods included data mining from reliable sources and collaboration of authors to consider and describe applications of research from outside RoM and to identify evidence-based strategies to reduce the burden of T2D in RoM. In 2014, the national prevalence of diabetes was 11.44% of the population (20-79 years) of RoM. Per capita caloric intake has increased significantly over the past 2 decades, with the majority of these calories coming from sugar, pork, chicken, beef, and sunflower oil. Excess calories, in the form of nutrient-deficient foods, animal products, and added oils promote insulin resistance and T2D. Tobacco use and lack of physical activity also contribute to the diabetes epidemic. Insulin, especially insulin analogues, are widely available and used to manage diabetes, often over other interventions that are more appropriate for patients with T2D, and more frequently than in other more developed countries, resulting in higher and unsustainable related costs. A new National eHealth System allows for better identification and monitoring of citizens with diabetes. However, the rapidly growing expense of insulin in the past has been unsustainable. The potential exists for a stronger role for lifestyle interventions in prevention and treatment of T2D. Significant changes in dietary patterns parallel the rise in diabetes prevalence and are likely a leading cause of diabetes and its complications. Research in RoM is needed to determine the impact and acceptability of dietary interventions for prevention and treatment of T2D, as a first step toward reduction of diabetes prevalence and its complications and controlling spiraling health care costs. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Performances of 27 MEDLINE systems tested by searches with clinical questions.

    PubMed Central

    Haynes, R B; Walker, C J; McKibbon, K A; Johnston, M E; Willan, A R

    1994-01-01

    OBJECTIVE: To compare the performances of online and compact-disc (CD-ROM) versions of the National Library of Medicine's (NLM) MEDLINE database. DESIGN: Analytic survey. INTERVENTION: Clinical questions were drawn from 18 searches originally conducted spontaneously by clinicians from wards and clinics who had used Grateful Med Version 4.0. Clinicians' search strategies were translated to meet the specific requirements of 13 online and 14 CD-ROM MEDLINE systems. A senior librarian and vendors' representatives constructed independent searches from the clinicians' questions. The librarian and clinician searches were run through each system, in command mode for the librarian and menu mode for clinicians, when available. Vendor searches were run through the vendors' own systems only. MAIN MEASUREMENTS: Numbers of relevant and irrelevant citations retrieved, cost (for online systems only), and time. RESULTS: Systems varied substantially for all searches, and for librarian and clinician searches separately, with respect to the numbers of relevant and irrelevant citations retrieved (p < 0.001 for both) and the cost per relevant citation (p = 0.012), but not with respect to the time per search. Based on combined rankings for the highest number of relevant and the lowest number of irrelevant citations retrieved, the SilverPlatter CD-ROM MEDLINE clinical journal subset performed best for librarian searches, while the PaperChase online system worked best for clinician searches. For cost per relevant citation retrieved, Dialog's Knowledge Index performed best for both librarian and clinician searches. CONCLUSIONS: There were substantial differences in the performances of competing MEDLINE systems, and performance was affected by search strategy, which was conceived by a librarian or by clinicians. PMID:7719810

  14. Longitudinal Changes in Hip Strength and Range of Motion in Female Youth Soccer Players: Implications for ACL Injury, A Pilot Study.

    PubMed

    Nguyen, Anh-Dung; Zuk, Emma F; Baellow, Andrea L; Pfile, Kate R; DiStefano, Lindsay J; Boling, Michelle C

    2017-09-01

    Risk of anterior cruciate ligament (ACL) injuries in young female athletes increases with age, appearing to peak during maturation. Changes in hip muscle strength and range of motion (ROM) during this time may contribute to altered dynamic movement patterns that are known to increase risk of ACL injuries. Understanding the longitudinal changes in hip strength and ROM is needed to develop appropriate interventions to reduce the risk of ACL injuries. To examine the longitudinal changes in hip strength and ROM in female youth soccer players. Longitudinal descriptive study. Field setting. 14 female youth soccer athletes (14.1 ± 1.1 y, 165.8 ± 5.3 cm, 57.5 ± 9.9 kg) volunteered as part of a multiyear risk factor screening project. Clinical measures of hip strength and ROM were collected annually over 3 consecutive years. Passive hip internal rotation (IR), external rotation (ER), abduction (ABD), and adduction (ADD) ROM were measured with a digital inclinometer. Isometric hip ABD and extension (EXT) strength were evaluated using a hand-held dynamometer. Separate repeated-measures ANOVAs compared hip strength and ROM values across 3 consecutive years (P < .05). As youth female soccer players increased in age, there were no changes in normalized hip ABD (P = .830) or EXT strength (P = .062) across 3 consecutive years. Longitudinal changes in hip ROM were observed with increases in hip IR (P = .001) and ABD (P < .001), while hip ADD (P = .009) and ER (P < .001) decreased. Anatomical changes at the hip occur as youth female soccer players increase in age. While there are no changes in hip strength, there is an increase in hip IR and ABD ROM with a concomitant decrease in hip ER and ADD ROM. The resulting asymmetries in hip ROM may decrease the activation and force producing capabilities of the hip muscles during dynamic activities, contributing to altered lower extremity mechanics known to increase the risk of ACL injuries.

  15. Development of less invasive neuromuscular electrical stimulation model for motor therapy in rodents

    PubMed Central

    Kanchiku, Tsukasa; Kato, Yoshihiko; Suzuki, Hidenori; Imajo, Yasuaki; Yoshida, Yuichiro; Moriya, Atsushi; Taguchi, Toshihiko; Jung, Ranu

    2012-01-01

    Background Combination therapy is essential for functional repairs of the spinal cord. Rehabilitative therapy can be considered as the key for reorganizing the nervous system after spinal cord regeneration therapy. Functional electrical stimulation has been used as a neuroprosthesis in quadriplegia and can be used for providing rehabilitative therapy to tap the capability for central nervous system reorganization after spinal cord regeneration therapy. Objective To develop a less invasive muscular electrical stimulation model capable of being combined with spinal cord regeneration therapy especially for motor therapy in the acute stage after spinal cord injury. Methods The tibialis anterior and gastrocnemius motor points were identified in intact anesthetized adult female Fischer rats, and stimulation needle electrodes were percutaneously inserted into these points. Threshold currents for visual twitches were obtained upon stimulation using pulses of 75 or 8 kHz for 200 ms. Biphasic pulse widths of 20, 40, 80, 100, 300, and 500 µs per phase were used to determine strength–duration curves. Using these parameters and previously obtained locomotor electromyogram data, stimulations were performed on bilateral joint muscle pairs to produce reciprocal flexion/extension movements of the ankle for 15 minutes while three-dimensional joint kinematics were assessed. Results Rhythmic muscular electrical stimulation with needle electrodes was successfully done, but decreased range of motion (ROM) over time. High-frequency and high-amplitude stimulation was also shown to be effective in alleviating decreases in ROM due to muscle fatigue. Conclusions This model will be useful for investigating the ability of rhythmic muscular electrical stimulation therapy to promote motor recovery, in addition to the efficacy of combining treatments with spinal cord regeneration therapy after spinal cord injuries. PMID:22507026

  16. Simulation of Lake Victoria Circulation Patterns Using the Regional Ocean Modeling System (ROMS).

    PubMed

    Nyamweya, Chrispine; Desjardins, Christopher; Sigurdsson, Sven; Tomasson, Tumi; Taabu-Munyaho, Anthony; Sitoki, Lewis; Stefansson, Gunnar

    2016-01-01

    Lake Victoria provides important ecosystem services including transport, water for domestic and industrial uses and fisheries to about 33 million inhabitants in three East African countries. The lake plays an important role in modulating regional climate. Its thermodynamics and hydrodynamics are also influenced by prevailing climatic and weather conditions on diel, seasonal and annual scales. However, information on water temperature and circulation in the lake is limited in space and time. We use a Regional Oceanographic Model System (ROMS) to simulate these processes from 1st January 2000 to 31st December 2014. The model is based on real bathymetry, river runoff and atmospheric forcing data using the bulk flux algorithm. Simulations show that the water column exhibits annual cycles of thermo-stratification (September-May) and mixing (June-August). Surface water currents take different patterns ranging from a lake-wide northward flow to gyres that vary in size and number. An under flow exists that leads to the formation of upwelling and downwelling regions. Current velocities are highest at the center of the lake and on the western inshore waters indicating enhanced water circulation in those areas. However, there is little exchange of water between the major gulfs (especially Nyanza) and the open lake, a factor that could be responsible for the different water quality reported in those regions. Findings of the present study enhance understanding of the physical processes (temperature and currents) that have an effect on diel, seasonal, and annual variations in stratification, vertical mixing, inshore-offshore exchanges and fluxes of nutrients that ultimately influence the biotic distribution and trophic structure. For instance information on areas/timing of upwelling and vertical mixing obtained from this study will help predict locations/seasons of high primary production and ultimately fisheries productivity in Lake Victoria.

  17. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Miyazaki, Kazuhide; Nishimura, Masayoshi

    Nippon Telegraph & Telephone Corporation (NTT) was the first company in the world to record the entire business classified Tokyo telephone directory containing more than 1,100,000 entries on CD-ROM. NTT's telephone directory on CD-ROM contains the business classification, the names, addresses and telephon numbers of more than 1,100,000 companies located in Tokyo’s 23 wards and surrounding towns. This report about NTT’s telephone directory on CD-ROM was written about the reason of development, outline, and the point at issue.

  18. A Dynamic Response Regulator Protein Modulates G-Protein–Dependent Polarity in the Bacterium Myxococcus xanthus

    PubMed Central

    Zhang, Yong; Guzzo, Mathilde; Ducret, Adrien; Li, Yue-Zhong; Mignot, Tâm

    2012-01-01

    Migrating cells employ sophisticated signal transduction systems to respond to their environment and polarize towards attractant sources. Bacterial cells also regulate their polarity dynamically to reverse their direction of movement. In Myxococcus xanthus, a GTP-bound Ras-like G-protein, MglA, activates the motility machineries at the leading cell pole. Reversals are provoked by pole-to-pole switching of MglA, which is under the control of a chemosensory-like signal transduction cascade (Frz). It was previously known that the asymmetric localization of MglA at one cell pole is regulated by MglB, a GTPase Activating Protein (GAP). In this process, MglB specifically localizes at the opposite lagging cell pole and blocks MglA localization at that pole. However, how MglA is targeted to the leading pole and how Frz activity switches the localizations of MglA and MglB synchronously remained unknown. Here, we show that MglA requires RomR, a previously known response regulator protein, to localize to the leading cell pole efficiently. Specifically, RomR-MglA and RomR-MglB complexes are formed and act complementarily to establish the polarity axis, segregating MglA and MglB to opposite cell poles. Finally, we present evidence that Frz signaling may regulate MglA localization through RomR, suggesting that RomR constitutes a link between the Frz-signaling and MglAB polarity modules. Thus, in Myxococcus xanthus, a response regulator protein governs the localization of a small G-protein, adding further insight to the polarization mechanism and suggesting that motility regulation evolved by recruiting and combining existing signaling modules of diverse origins. PMID:22916026

  19. Cervical motion assessment using virtual reality.

    PubMed

    Sarig-Bahat, Hilla; Weiss, Patrice L; Laufer, Yocheved

    2009-05-01

    Repeated measures of cervical motion in asymptomatic subjects. To introduce a virtual reality (VR)-based assessment of cervical range of motion (ROM); to establish inter and intratester reliability of the VR-based assessment in comparison with conventional assessment in asymptomatic individuals; and to evaluate the effect of a single VR session on cervical ROM. Cervical ROM and clinical issues related to neck pain is frequently studied. A wide variety of methods is available for evaluation of cervical motion. To date, most methods rely on voluntary responses to an assessor's instructions. However, in day-to-day life, head movement is generally an involuntary response to multiple stimuli. Therefore, there is a need for a more functional assessment method, using sensory stimuli to elicit spontaneous neck motion. VR attributes may provide a methodology for achieving this goal. A novel method was developed for cervical motion assessment utilizing an electromagnetic tracking system and a VR game scenario displayed via a head mounted device. Thirty asymptomatic participants were assessed by both conventional and VR-based methods. Inter and intratester repeatability analyses were performed. The effect of a single VR session on ROM was evaluated. Both assessments showed non-biased results between tests and between testers (P > 0.1). Full-cycle repeatability coefficients ranged between 15.0 degrees and 29.2 degrees with smaller values for rotation and for the VR assessment. A single VR session significantly increased ROM, with largest effect found in the rotation direction. Inter and intratester reliability was supported for both the VR-based and the conventional methods. Results suggest better repeatability for the VR method, with rotation being more precise than flexion/extension. A single VR session was found to be effective in increasing cervical motion, possibly due to its motivating effect.

  20. Three-dimensional movements of the pelvis and the lumbar intervertebral joints in walking and trotting dogs.

    PubMed

    Wachs, K; Fischer, M S; Schilling, N

    2016-04-01

    Current knowledge of the physiological range of motion (ROM) in the canine axial system during locomotion is relatively limited. This is particularly problematic because dogs with back-related dysfunction frequently present for routine consultations. To collect detailed kinematic information and describe the three-dimensional motions of the pelvis and the lumbar spine (i.e. intervertebral joints S1/L7-L2/L1), we recorded ventro-dorsal and latero-lateral X-ray videos of three walking and trotting dogs and reconstructed their pelvic and intervertebral motions using X-ray reconstruction of moving morphology and scientific rotoscoping. Pelvic roll displayed a monophasic motion pattern and the largest ROM with on average 13° and 11° during walking and trotting, respectively. Pelvic yaw had the smallest ROM with on average 5° (walk) and 6° (trot). A biphasic pattern was observed for pelvic pitch with a mean ROM of 8°. At both gaits, the greatest intervertebral motions occurred either in S1/L7 or L7/L6. The intervertebral motions were mono- or biphasic in the horizontal and the transverse body planes and biphasic in the sagittal plane. Cranial to L6/5, the ROM tended to decrease from 3° to <1.5° in all three planes. Our results confirm that pelvic displacement and intervertebral joint movements are tightly linked with pelvic limb action at symmetrical gaits. The overall small movements, particularly cranial to L5, are consistent with the epaxial musculature globally stabilising the spine against the external and internal limb forces acting on the pelvis and the trunk during walking and trotting. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. The Application of a Modified d-ROMs Test for Measurement of Oxidative Stress and Oxidized High-Density Lipoprotein

    PubMed Central

    Ito, Fumiaki; Ito, Tomoyuki; Suzuki, Chinatsu; Yahata, Tomoyo; Ikeda, Kazuyuki; Hamaoka, Kenji

    2017-01-01

    Reactive oxygen species (ROS) are involved in the initiation and progression of atherosclerosis. ROS-derived hydroperoxides, as an indicator of ROS production, have been measured by using the diacron reactive oxygen metabolites (d-ROMs) test, which requires iron-containing transferrin in the reaction mixture. In this study we developed a modified d-ROMs test, termed the Fe-ROMs test, where iron ions were exogenously added to the reaction mixture. This modification is expected to exclude the assay variation that comes from different blood iron levels in individuals. In addition, this Fe-ROMs test was helpful for determining the class of plasma lipoproteins that are hydroperoxidized. Low-density lipoprotein/very low-density lipoprotein (LDL/VLDL) and high-density lipoprotein (HDL) were purified by use of an LDL/VLDL purification kit and the dextran sulfate-Mg2+ precipitation method, respectively; their hydroperoxide contents were assessed by performing the Fe-ROMs test. The majority of the hydroperoxides were detected only in the HDL fraction, not in the LDL/VLDL. Further detailed analysis of HDLs by size-exclusion high-performance liquid chromatography revealed that the hydroperoxide-containing molecules were small-sized HDLs. Because HDL was shown to be the principal vehicle for the plasma hydroperoxides, this Fe-ROMs test is a beneficial method for the assessment of oxidized-HDL levels. Indeed, Fe-ROMs levels were strongly associated with the levels of oxidized HDL, which were determined by performing the malondialdehyde-modified HDL enzyme immunoassay. In conclusion, the Fe-ROMs test using plasma itself or the HDL fraction after dextran sulfate-Mg2+ precipitation is useful to assess the functionality of HDL, because the oxidation of HDL impairs its antiatherogenic capacity. PMID:28230785

  2. The Application of a Modified d-ROMs Test for Measurement of Oxidative Stress and Oxidized High-Density Lipoprotein.

    PubMed

    Ito, Fumiaki; Ito, Tomoyuki; Suzuki, Chinatsu; Yahata, Tomoyo; Ikeda, Kazuyuki; Hamaoka, Kenji

    2017-02-21

    Reactive oxygen species (ROS) are involved in the initiation and progression of atherosclerosis. ROS-derived hydroperoxides, as an indicator of ROS production, have been measured by using the diacron reactive oxygen metabolites (d-ROMs) test, which requires iron-containing transferrin in the reaction mixture. In this study we developed a modified d-ROMs test, termed the Fe-ROMs test, where iron ions were exogenously added to the reaction mixture. This modification is expected to exclude the assay variation that comes from different blood iron levels in individuals. In addition, this Fe-ROMs test was helpful for determining the class of plasma lipoproteins that are hydroperoxidized. Low-density lipoprotein/very low-density lipoprotein (LDL/VLDL) and high-density lipoprotein (HDL) were purified by use of an LDL/VLDL purification kit and the dextran sulfate-Mg 2+ precipitation method, respectively; their hydroperoxide contents were assessed by performing the Fe-ROMs test. The majority of the hydroperoxides were detected only in the HDL fraction, not in the LDL/VLDL. Further detailed analysis of HDLs by size-exclusion high-performance liquid chromatography revealed that the hydroperoxide-containing molecules were small-sized HDLs. Because HDL was shown to be the principal vehicle for the plasma hydroperoxides, this Fe-ROMs test is a beneficial method for the assessment of oxidized-HDL levels. Indeed, Fe-ROMs levels were strongly associated with the levels of oxidized HDL, which were determined by performing the malondialdehyde-modified HDL enzyme immunoassay. In conclusion, the Fe-ROMs test using plasma itself or the HDL fraction after dextran sulfate-Mg 2+ precipitation is useful to assess the functionality of HDL, because the oxidation of HDL impairs its antiatherogenic capacity.

  3. Higher Serum Uric Acid May Contribute to Cerebral Infarction in Patients with Type 2 Diabetes Mellitus: a Meta-Analysis.

    PubMed

    Du, Lei; Ma, Jianhua; Zhang, Xiaoning

    2017-01-01

    Higher levels of serum uric acid tend to increase the diabetes-related complications. We performed a meta-analysis to investigate whether the higher serum uric acid levels were associated with cerebral infarction in type 2 diabetes patients. We searched for relevant studies in the PubMed, Embase, China National Knowledge Infrastructure, China BioMedicine, and VIP database until August 2015. All observational studies comparing serum uric acid levels in type 2 diabetic patients with and without cerebral infarction were included. We calculated the ratio of means (RoM) of serum uric acid by mean cerebral infarction /mean diabetic control from the individual studies and then pooled RoM and its 95 % confidence intervals (CI). A total of 23 eligible studies were identified. Pooled estimates indicated that type 2 diabetes patients with cerebral infarction were associated with 29 % (RoM 1.29; 95 % CI 1.26-1.31) higher serum uric acid levels than those without cerebral infarction in a random effect model. Subgroup analyses based on gender indicated that RoM was 1.23 (95 % CI 1.09-1.38) for men and 1.12 (95 % CI 0.98-1.27) for women. This meta-analysis suggests that higher serum uric acid levels may contribute to cerebral infarction in patients with type 2 diabetes.

  4. Database Access Systems.

    ERIC Educational Resources Information Center

    Dalrymple, Prudence W.; Roderer, Nancy K.

    1994-01-01

    Highlights the changes that have occurred from 1987-93 in database access systems. Topics addressed include types of databases, including CD-ROMs; enduser interface; database selection; database access management, including library instruction and use of primary literature; economic issues; database users; the search process; and improving…

  5. Networking CD-ROMs: A Tutorial Introduction.

    ERIC Educational Resources Information Center

    Perone, Karen

    1996-01-01

    Provides an introduction to CD-ROM networking. Highlights include LAN (local area network) architectures for CD-ROM networks, peer-to-peer networks, shared file and dedicated file servers, commercial software/vendor solutions, problems, multiple hardware platforms, and multimedia. Six figures illustrate network architectures and a sidebar contains…

  6. NASA space and Earth science data on CD-ROM

    NASA Technical Reports Server (NTRS)

    Towheed, Syed S.

    1993-01-01

    The National Space Science Data Center (NSSDC) is very interested in facilitating the widest possible use of the scientific data acquired through NASA spaceflight missions. Therefore, NSSDC has participated with projects and data management elements throughout the NASA science environment in the creation, archiving, and dissemination of data using Compact Disk-Read Only Memory (CD-ROM). This CD-ROM technology has the potential to enable the dissemination of very large data volumes at very low prices to a great many researchers, students and their teachers, and others. This catalog identifies and describes the scientific CD-ROM's now available from NSSDC including the following data sets: Einstein Observatory CD-ROM, Galileo Cruise Imaging on CD-ROM, International Halley Watch, IRAS Sky Survey Atlas, Infrared Thermal Mapper (IRTM), Magellan (MIDR), Magellan (ARCDR's), Magellan (GxDR's), Mars Digital Image Map (MDIM), Outer Planets Fields & Particles Data, Pre-Magellan, Selected Astronomical Catalogs, TOMS Gridded Ozone Data, TOMS Ozone Image Data, TOMS Update, Viking Orbiter Images of Mars, and Voyager Image.

  7. Amount of torque and duration of stretching affects correction of knee contracture in a rat model of spinal cord injury.

    PubMed

    Moriyama, Hideki; Tobimatsu, Yoshiko; Ozawa, Junya; Kito, Nobuhiro; Tanaka, Ryo

    2013-11-01

    Joint contractures are a common complication of many neurologic conditions, and stretching often is advocated to prevent and treat these contractures. However, the magnitude and duration of the stretching done in practice usually are guided by subjective clinical impressions. Using an established T8 spinal cord injury rat model of knee contracture, we sought to determine what combination of static or intermittent stretching, varied by magnitude (high or low) and duration (long or short), leads to the best (1) improvement in the limitation in ROM; (2) restoration of the muscular and articular factors leading to contractures; and (3) prevention and treatment of contracture-associated histologic alterations of joint capsule and articular cartilage. Using a rat animal model, the spinal cord was transected completely at the level of T8. The rats were randomly assigned to seven treatment groups (n = 4 per group), which were composed of static or intermittent stretching in combination with different amounts of applied torque magnitude and duration. We assessed the effect of stretching by measuring the ROM and evaluating the histologic alteration of the capsule and cartilage. Contractures improved in all treated groups except for the low-torque and short-duration static stretching conditions. High-torque stretching was effective against shortening of the synovial membrane and adhesions in the posterosuperior regions. Collagen Type II and VEGF in the cartilage were increased by stretching. High-torque and long-duration static stretching led to greater restoration of ROM than the other torque and duration treatment groups. Stretching was more effective in improving articular components of contractures compared with the muscular components. Stretching in this rat model prevented shortening and adhesion of the joint capsule, and affected biochemical composition, but did not change morphologic features of the cartilage. This animal study tends to support the ideas that static stretching can influence joint ROM and histologic qualities of joint tissues, and that the way stretching is performed influences its efficacy. However, further studies are warranted to determine if our findings are clinically applicable.

  8. Evaluation of two CD-ROMs from a series on cell biology.

    PubMed

    Sander, Uwe; Kerlen, Gertraude; Steinke, Mattias; Huk, Thomas; Floto, Christian

    2003-01-01

    Two CD-ROMs from a series dealing with various major aspects of cell biology are evaluated in this paper using quantitative and qualitative approaches. The findings delimit similarities and differences of the two CD-ROMs and shed light on how the programs could be used in the learning process and how they should not be. The overall impression, as well as the graphical and technical features, received a predominantly good rating. The defined target groups were reached (e.g., students in secondary schools), different learning approaches were supported (e.g., discovery and autonomous learning), the CD-ROMs' usability was assessed as being easy and intuitive, and the majority of the evaluators were satisfied with the level of interactivity. Navigational problems encountered in CD-ROM 1 were overcome by a successful implementation of new navigational functions in CD-ROM 2. Most students found the CD-ROM to be a suitable complement to, or an extension of, their lessons. We conclude that many, but not all of the requirements for the various stages of the learning process could be satisfied with the existing CD-ROMs. The requirements not met are discussed to obtain insights that could help to improve the production of multimedia learning material. The use of quantitative and qualitative approaches in the evaluation of learning modules is discussed, as the study began by collecting and analyzing anecdotal reviews and was then extended to include a qualitative evaluation.

  9. White Blood Cells, Neutrophils, and Reactive Oxygen Metabolites among Asymptomatic Subjects.

    PubMed

    Kotani, Kazuhiko; Sakane, Naoki

    2012-06-01

    Chronic inflammation and oxidative stress are associated with health and the disease status. The objective of the present study was to investigate the association among white blood cell (WBC) counts, neutrophil counts as a WBC subpopulation, and diacron reactive oxygen metabolites (d-ROMs) levels in an asymptomatic population. The clinical data, including general cardiovascular risk variables and high-sensitivity C-reactive protein (hs-CRP), were collected from 100 female subjects (mean age, 62 years) in outpatient clinics. The correlation of the d-ROMs with hs-CRP, WBC, and neutrophil counts was examined. The mean/median levels were WBC counts 5.9 × 10(9)/L, neutrophil counts 3.6 × 10(9)/L, hs-CRP 0.06 mg/dL, and d-ROMs 359 CURR U. A simple correlation analysis showed a significant positive correlation of the d-ROMs with the WBC counts, neutrophil counts, or hs-CRP levels. The correlation between d-ROMs and neutrophil counts (β = 0.22, P < 0.05), as well as that between d-ROMs and hs-CRP (β = 0.28, P < 0.01), remained significant and independent in a multiple linear regression analysis adjusted for other variables. A multiple linear regression analysis showed that WBC counts had only a positive correlation tendency to the d-ROMs. Neutrophils may be slightly but more involved in the oxidative stress status, as assessed by d-ROMs, in comparison to the overall WBC. Further studies are needed to clarify the biologic mechanism(s) of the observed relationship.

  10. Evaluation of Two CD-ROMs from a Series on Cell Biology

    PubMed Central

    Sander, Uwe; Kerlen, Gertraude; Steinke, Mattias; Huk, Thomas; Floto, Christian

    2003-01-01

    Two CD-ROMs from a series dealing with various major aspects of cell biology are evaluated in this paper using quantitative and qualitative approaches. The findings delimit similarities and differences of the two CD-ROMs and shed light on how the programs could be used in the learning process and how they should not be. The overall impression, as well as the graphical and technical features, received a predominantly good rating. The defined target groups were reached (e.g., students in secondary schools), different learning approaches were supported (e.g., discovery and autonomous learning), the CD-ROMs' usability was assessed as being easy and intuitive, and the majority of the evaluators were satisfied with the level of interactivity. Navigational problems encountered in CD-ROM 1 were overcome by a successful implementation of new navigational functions in CD-ROM 2. Most students found the CD-ROM to be a suitable complement to, or an extension of, their lessons. We conclude that many, but not all of the requirements for the various stages of the learning process could be satisfied with the existing CD-ROMs. The requirements not met are discussed to obtain insights that could help to improve the production of multimedia learning material. The use of quantitative and qualitative approaches in the evaluation of learning modules is discussed, as the study began by collecting and analyzing anecdotal reviews and was then extended to include a qualitative evaluation. PMID:14673491

  11. Advanced Computational Methods for Thermal Radiative Heat Transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tencer, John; Carlberg, Kevin Thomas; Larsen, Marvin E.

    2016-10-01

    Participating media radiation (PMR) in weapon safety calculations for abnormal thermal environments are too costly to do routinely. This cost may be s ubstantially reduced by applying reduced order modeling (ROM) techniques. The application of ROM to PMR is a new and unique approach for this class of problems. This approach was investigated by the authors and shown to provide significant reductions in the computational expense associated with typical PMR simulations. Once this technology is migrated into production heat transfer analysis codes this capability will enable the routine use of PMR heat transfer in higher - fidelity simulations of weaponmore » resp onse in fire environments.« less

  12. Fit to predict? Eco-informatics for predicting the catchability of a pelagic fish in near real time.

    PubMed

    Scales, Kylie L; Hazen, Elliott L; Maxwell, Sara M; Dewar, Heidi; Kohin, Suzanne; Jacox, Michael G; Edwards, Christopher A; Briscoe, Dana K; Crowder, Larry B; Lewison, Rebecca L; Bograd, Steven J

    2017-12-01

    The ocean is a dynamic environment inhabited by a diverse array of highly migratory species, many of which are under direct exploitation in targeted fisheries. The timescales of variability in the marine realm coupled with the extreme mobility of ocean-wandering species such as tuna and billfish complicates fisheries management. Developing eco-informatics solutions that allow for near real-time prediction of the distributions of highly mobile marine species is an important step towards the maturation of dynamic ocean management and ecological forecasting. Using 25 yr (1990-2014) of NOAA fisheries' observer data from the California drift gillnet fishery, we model relative probability of occurrence (presence-absence) and catchability (total catch per gillnet set) of broadbill swordfish Xiphias gladius in the California Current System. Using freely available environmental data sets and open source software, we explore the physical drivers of regional swordfish distribution. Comparing models built upon remotely sensed data sets with those built upon a data-assimilative configuration of the Regional Ocean Modelling System (ROMS), we explore trade-offs in model construction, and address how physical data can affect predictive performance and operational capacity. Swordfish catchability was found to be highest in deeper waters (>1,500 m) with surface temperatures in the 14-20°C range, isothermal layer depth (ILD) of 20-40 m, positive sea surface height (SSH) anomalies, and during the new moon (<20% lunar illumination). We observed a greater influence of mesoscale variability (SSH, wind speed, isothermal layer depth, eddy kinetic energy) in driving swordfish catchability (total catch) than was evident in predicting the relative probability of presence (presence-absence), confirming the utility of generating spatiotemporally dynamic predictions. Data-assimilative ROMS circumvent the limitations of satellite remote sensing in providing physical data fields for species distribution models (e.g., cloud cover, variable resolution, subsurface data), and facilitate broad-scale prediction of dynamic species distributions in near real time. © 2017 by the Ecological Society of America.

  13. Exploring CD-ROM Encyclopedias.

    ERIC Educational Resources Information Center

    Urrows, Henry; Urrows, Elizabeth

    1989-01-01

    Review of encyclopedias and other databases available on CD-ROM focuses on the International Encyclopedia of Education (IEE). Problems with software and hardware are described, perspectives from the computer industry are presented, the commercial potential of CD-ROMs is discussed, and a list of sources is provided. (six references) (LRW)

  14. Choosing a CD-ROM Encyclopedia: How to Critically Evaluate the Product.

    ERIC Educational Resources Information Center

    Dickinson, Gail

    1990-01-01

    Offers criteria for the critical evaluation of CD-ROM encyclopedias. Differences between CD-ROM and print encyclopedias are discussed; search strategies are explained; evaluation criteria are suggested, including help messages, screen format, indexing method, and graphics and print options; future considerations are suggested, including…

  15. CD-ROMs Proliferate--Part 2: Business/Science/Government CD-ROM Disks.

    ERIC Educational Resources Information Center

    Desmarais, Norman

    1989-01-01

    This second of a two-part article on CD-ROM products highlights applications relating to business, medicine, law, government, education, science, geography, linguistics, aviation, florists, and newsreel summaries. The names and addresses of 45 vendors connected with the optical publishing industry are listed. (LRW)

  16. Lumbar Spine Alignment in Six Common Postures: An ROM Analysis With Implications for Deformity Correction.

    PubMed

    Hey, Hwee Weng Dennis; Lau, Eugene Tze-Chun; Tan, Kimberly-Anne; Lim, Joel L; Choong, Denise; Lau, Leok-Lim; Liu, Ka-Po G; Wong, Hee-Kit

    2017-10-01

    A cross-sectional study of prospectively collected data. To compare lumbar spine alignment in six common postures, and estimate loss in range of motion (ROM) relative to standing. Ideal position for fusion of lumbar spine remains unknown. Although surgical fusion is necessary for deformity correction and symptom relief, the final position in which the vertebrae are immobilized should provide maximum residual function. Data were collected prospectively from 70 patients with low back pain recruited over a year. All subjects had x-rays performed in slump sitting, forward bending, supine, half squatting, standing, and backward bending postures. ROM quantified in terms of sagittal global and segmental Cobb angles was measured from L1 to S1. Loss of ROM relative to standing was calculated for each posture. Analysis of variance and unpaired t tests were used to identify differences in alignment between postures. Slump sitting gives the greatest lumbar flexion followed by forward bending, and supine postures (P < 0.001). Backward bending produces greater lumbar extension than standing (P = 0.035). Half-squatting and standing postures were not significantly different (P = 0.938). For all postures, L4-5 and L5-S1 segments remained in lordosis, with L4-5 having greater ROM than L5-S1. L1-2 turns kyphotic in lying supine, L2-3 at forward bending, and L3-4 at slump sitting in the form of a "kyphosing cascade." Should the entire lumbar spine be fused in standing position from L1-S1, there would likely be a mean loss of 47.6° of lumbar flexion and 5.9° of lumbar extension. The present study demonstrates the extent of flexibility required of the lumbar spine in assuming various postures. It also enables comparison of the differences in degree of motion occurring in the lumbar spine, both across postures and across segments. Significant loss in ROM, particularly flexion, is anticipated with fusion modeled after the lordotic standing lumbar spine. 2.

  17. Preconditioning of the background error covariance matrix in data assimilation for the Caspian Sea

    NASA Astrophysics Data System (ADS)

    Arcucci, Rossella; D'Amore, Luisa; Toumi, Ralf

    2017-06-01

    Data Assimilation (DA) is an uncertainty quantification technique used for improving numerical forecasted results by incorporating observed data into prediction models. As a crucial point into DA models is the ill conditioning of the covariance matrices involved, it is mandatory to introduce, in a DA software, preconditioning methods. Here we present first studies concerning the introduction of two different preconditioning methods in a DA software we are developing (we named S3DVAR) which implements a Scalable Three Dimensional Variational Data Assimilation model for assimilating sea surface temperature (SST) values collected into the Caspian Sea by using the Regional Ocean Modeling System (ROMS) with observations provided by the Group of High resolution sea surface temperature (GHRSST). We also present the algorithmic strategies we employ.

  18. Toward the S3DVAR data assimilation software for the Caspian Sea

    NASA Astrophysics Data System (ADS)

    Arcucci, Rossella; Celestino, Simone; Toumi, Ralf; Laccetti, Giuliano

    2017-07-01

    Data Assimilation (DA) is an uncertainty quantification technique used to incorporate observed data into a prediction model in order to improve numerical forecasted results. The forecasting model used for producing oceanographic prediction into the Caspian Sea is the Regional Ocean Modeling System (ROMS). Here we propose the computational issues we are facing in a DA software we are developing (we named S3DVAR) which implements a Scalable Three Dimensional Variational Data Assimilation model for assimilating sea surface temperature (SST) values collected into the Caspian Sea with observations provided by the Group of High resolution sea surface temperature (GHRSST). We present the algorithmic strategies we employ and the numerical issues on data collected in two of the months which present the most significant variability in water temperature: August and March.

  19. Implementation and validation of a current model system in the greatest sound in the North East Atlantic archipelago of the Faroe Islands

    NASA Astrophysics Data System (ADS)

    Vagsheyg Erenbjerg, Sissal; Albretsen, Jon; Asplin, Lars; Joensen, Erna; Sandvik, Anne; Simonsen, Knud; Kaas, Eigil

    2017-04-01

    The location of the Faroe Islands on the Greenland-Scotland ridge puts the oceanography on the boundary of deep water and shelf and fjord dynamics. This placement in close proximity of the deep ocean currents, important for heat transport towards the Arctic, makes the Faroe Islands higly exposed to climate change. Therefore it is important to understand the interaction of deep water oceanography and fjord dynamics in general, to be able to predict potential impact, due to changes in ocean parameters. The Faroe Islands consist of 18 islands. The topographic characteristics are typical for an ice sheet shaped land surface with long and slim islands, steep mountain sides divided by narrow and relatively deep fjords. This highly complex topography is greatly influenced by wind conditions. Sundalagið separates the two largest islands: Streymoy and Eysturoy and has three fjordarms and two main basins. The northern part (SUN) is 15km long and 100m-1.6km wide. The sound is bound to the north by a 9m deep sill. Towards the south by a narrowing of a 100 meter wide and around four meter deep sill, depending on tidal conditions. The southern part (SUS) is not as clearly constricted but contains three major basins with depths ranging from 70-100m (Hansen et al., 1990). We have implemented a nested model system using high resolution bathymetry in the fjords and the entire shelf as well as the open-source hydrodynamical model ROMS (Regional Ocean Modeling System, http://myroms.org). The Faroe Islands model applications are using triply, one way nested grids with 800 → 160 → 32 meter resolutions in the horizontal. This gives us the opportunity to both simulate the deep water oceanography applying 800m resolution as well as the dynamics in the shallow regions using finer resolution models. A particular interest in the area is the influence of the tidal regime. In SUN the tidal dynamics are quite limited due to the location of an amphidromeice point in the Nolsoy fjord (M2=10.4cm (www.dmi.dk)) whereas SUN is heavily dominated by tidal dynamics (M2=63.1cm). The general observation is a more pronounced stratification in SUN and higher vertical mixing in the water column in SUS (2016 CTD mesurements). Our ROMS simulations are run for the year 2013 (only part of the year for the 32m resolution) and forced with high-resolution atmospheric conditions (WRF-1km), large-scale ocean fields (ROMS 4km) of currents, hydrography and sea level (Lien et al., 2014), global tides (TPXO7.2) and climatological freshwater discharges including the main rivers. In this study we validate the model simulations using in-situ data coverage (ACDP) in the local area. A well-functioning dynamical model system is highly important for the Faroe Islands where aquaculture is by far the greatest industry. Linking this to a particle tracking module will further increase the understanding of climate impact in the Faroes in particular with regards to the changes for the biological cycle and mitigation of sea lice (a challenging parasite for the aquaculture) by temperature changes.

  20. Predicting long-term performance of engineered geologic carbon dioxide storage systems to inform decisions amidst uncertainty

    NASA Astrophysics Data System (ADS)

    Pawar, R.

    2016-12-01

    Risk assessment and risk management of engineered geologic CO2 storage systems is an area of active investigation. The potential geologic CO2 storage systems currently under consideration are inherently heterogeneous and have limited to no characterization data. Effective risk management decisions to ensure safe, long-term CO2 storage requires assessing and quantifying risks while taking into account the uncertainties in a storage site's characteristics. The key decisions are typically related to definition of area of review, effective monitoring strategy and monitoring duration, potential of leakage and associated impacts, etc. A quantitative methodology for predicting a sequestration site's long-term performance is critical for making key decisions necessary for successful deployment of commercial scale geologic storage projects where projects will require quantitative assessments of potential long-term liabilities. An integrated assessment modeling (IAM) paradigm which treats a geologic CO2 storage site as a system made up of various linked subsystems can be used to predict long-term performance. The subsystems include storage reservoir, seals, potential leakage pathways (such as wellbores, natural fractures/faults) and receptors (such as shallow groundwater aquifers). CO2 movement within each of the subsystems and resulting interactions are captured through reduced order models (ROMs). The ROMs capture the complex physical/chemical interactions resulting due to CO2 movement and interactions but are computationally extremely efficient. The computational efficiency allows for performing Monte Carlo simulations necessary for quantitative probabilistic risk assessment. We have used the IAM to predict long-term performance of geologic CO2 sequestration systems and to answer questions related to probability of leakage of CO2 through wellbores, impact of CO2/brine leakage into shallow aquifer, etc. Answers to such questions are critical in making key risk management decisions. A systematic uncertainty quantification approach can been used to understand how uncertain parameters associated with different subsystems (e.g., reservoir permeability, wellbore cement permeability, wellbore density, etc.) impact the overall site performance predictions.

  1. Story Games: Marrying Silicon, Celluloid, and CD-ROM.

    ERIC Educational Resources Information Center

    Gussin, Lawrence

    1994-01-01

    Reports on themes emphasized at the April 1994 Computer Game Developers Conference held in Santa Clara (California), including the exploding CD-ROM marketplace and the potential and challenge of using CD-ROM's multimedia capacity to build cinema-quality stories and characters into computer games. Strategies for introducing more complex plots are…

  2. NASA educational CD-ROMs: research and evaluation

    NASA Technical Reports Server (NTRS)

    Knudsen, R.

    2002-01-01

    Since the introduction of educational technology in the K-12 classroom, educators have been flooded with a seemingly endless flow of educational CD-ROMs. NASA has contributed to this new trend in educational technology by developing a wide range of some of the lastest, most high-tech CD-ROMs in the industry.

  3. CD-ROM: A New Light for the Blind and Visually Impaired.

    ERIC Educational Resources Information Center

    Mates, Barbara T.

    1990-01-01

    Describes ways of using CD-ROM technology for the benefit of blind and visually impaired library patrons. Science, reference, and American historical documents that can be converted to braille, large print, or voice output from CD-ROMs are described, and hardware, software, and staff considerations are discussed. (LRW)

  4. Are CD-ROM LANs a Thing of the Past?

    ERIC Educational Resources Information Center

    Mehta, Apurva

    1996-01-01

    Remote access to full-text and CD-ROM databases using the Internet has advantages over a CD-ROM local area network. Topics include speed, document delivery, multiple platforms, technical support, licensing, copyright, and access to graphics. Considerations of duplication of information, platform compatibility, print versus digital media, back…

  5. CD-ROM Integration Peaks Student Interest in Inquiry.

    ERIC Educational Resources Information Center

    O'Bannon, Blanche

    1997-01-01

    Discussion of learning processes examines past educational practices and considers how CD-ROM technology can impact teaching and learning. A lesson plan for elementary school science that uses a CD-ROM encyclopedia is presented that includes instructional goals, performance objectives, teaching and learning activities, and assessment methods.…

  6. Scaffolding or Distracting: CD-ROM Storybooks and Young Readers

    ERIC Educational Resources Information Center

    Pearman, Cathy J.; Chang, Ching-Wen

    2010-01-01

    CD-ROM storybooks, often referred to as electronic texts, e-books, and interactive stories, are learning tools with supplemental features such as automatic reading of text, sound effects, word pronunciations, and graphic animations which support the development of reading skills and comprehension in beginning readers. Some CD-ROM storybooks also…

  7. Annelids. A Multimedia CD-ROM. [CD-ROM].

    ERIC Educational Resources Information Center

    2001

    This CD-ROM is designed for classroom and individual use to teach and learn about annelids. Integrated animations, custom graphics, three-dimensional representations, photographs, and sound are featured for use in user-controlled activities. Interactive lessons are available to reinforce the subject material. Pre- and post-testing sections are…

  8. My Favorite Things Electronically Speaking, 1997 Edition.

    ERIC Educational Resources Information Center

    Glantz, Shelley

    1997-01-01

    Responding to an informal survey, 96 media specialists named favorite software, CD-ROMs, and online sites. This article lists automation packages, electronic encyclopedias, CD-ROMs, electronic magazine indexes, CD-ROM and online database services, electronic sources of current events, laser disks for grades 6-12, word processing programs for…

  9. Effectiveness of a Lab Manual Delivered on CD-ROM

    ERIC Educational Resources Information Center

    Brickman, Peggy; Ketter, Catherine A. Teare; Pereira, Monica

    2005-01-01

    Although electronic instructional media are becoming increasingly prevalent in science classrooms, their worth remains unproven. Here, student perceptions and performance using CD-ROM delivery of lab materials are assessed. Numerous learning barriers that produced lower lab grades for students using a CD-ROM lab manual in comparison to a print…

  10. Publication Of Oceanographic Data on CD-ROM

    NASA Technical Reports Server (NTRS)

    Hilland, Jeffrey E.; Smith, Elizabeth A.; Martin, Michael D.

    1992-01-01

    Large collections of oceanographic data and other large collections of data published on CD-ROM's in formats facilitating access and analysis. Involves four major steps: preprocessing, premastering, mastering, and verification. Large capacity, small size, commercial availability, long-life, and standard format of CD-ROM's offer advantages over computer-compatible magnetic tape.

  11. An Experimental Test of CD-ROM Aided Instruction in Transnational Management.

    ERIC Educational Resources Information Center

    Oviatt, Benjamin M.; Bansal, Ptraima; Houghton, Susan

    2000-01-01

    Twenty-seven graduate students used a CD-ROM program to study transnational management, while a control group (n=26) used traditional study methods. Use of the CD-ROM was not associated with better examination performance. Implications for increased investment in new classroom technology are drawn. (Author/DB)

  12. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Masuyama, Keiichi

    CD-ROM has rapidly evolved as a new information medium with large capacity, In the U.S. it is predicted that it will become two hundred billion yen market in three years, and thus CD-ROM is strategic target of database industry. Here in Japan the movement toward its commercialization has been active since this year. Shall CD-ROM bussiness ever conquer information market as an on-disk database or electronic publication? Referring to some cases of the applications in the U.S. the author views marketability and the future trend of this new optical disk medium.

  13. The Relation Between Stretching Typology and Stretching Duration: The Effects on Range of Motion.

    PubMed

    Thomas, Ewan; Bianco, Antonino; Paoli, Antonio; Palma, Antonio

    2018-04-01

    Different stretching strategies and protocols are widely used to improve flexibility or maintain health, acting on the muscle tendon-unit, in order to improve the range of motion (ROM) of the joints. This review aims to evaluate the current body of literature in order to understand the relation between stretching typology and ROM, and secondly to evaluate if a relation exists between stretching volume (either as a single training session, weekly training and weekly frequency) and ROM, after long-term stretching. Twenty-three articles were considered eligible and included in the quantitative synthesis. All stretching typologies showed ROM improvements over a long-term period, however the static protocols showed significant gains (p<0.05) when compared to the ballistic or PNF protocols. Time spent stretching per week seems fundamental to elicit range of movement improvements when stretches are applied for at least or more than 5 min, whereas the time spent stretching within a single session does not seem to have significant effects for ROM gains. Weekly frequency is positively associated to ROM. Evaluated data indicates that performing stretching at least 5 days a week for at least 5 min per week using static stretching may be beneficial to promote ROM improvements. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Reactive oxygen metabolites (ROMs) as an index of oxidative stress in obstructive sleep apnea patients.

    PubMed

    Christou, Kostas; Markoulis, Nikolaos; Moulas, Anargyros N; Pastaka, Chaido; Gourgoulianis, Kostantinos I

    2003-09-01

    Obstructive sleep apnea syndrome (OSA) is accompanied by oxygen desaturation and arousal from sleep. Free oxygen radicals are highly reactive molecules which could be produced by the OSA phenomenon of hypoxia/reoxygenation: cyclical alterations of arterial oxygen saturation with oxygen desaturation developing in response to apneas followed by resumption of oxygen saturation during hyperventilation. On the basis of these considerations, it was hypothesized that OSA may be linked to increased oxidative stress. Twenty-six participants gave an interview during which a physician asked them about their age, smoking habits, and symptoms such as excessive daytime sleepiness and snoring. Physical examination and polysomnography were performed during their hospitalization. Reactive oxygen metabolites (ROMs) were measured in blood samples by the diacron reactive oxygen metabolites (D-ROM) test. Twenty-one out of 26 subjects had an apnea/hypopnea index greater than 5 (OSA group). The measurement of free radicals was high in OSA patients. Furthermore, ROMs values in OSA patients were linearly correlated with the apnea/hypopnea index (R = 0.426; p = 0.042). The predictive value of a positive D-ROM test is 81%. ROMs were elevated in patients with OSA. When OSA was severe, similarly the value of ROMs in blood samples was enhanced, and the probable underlying mechanism for these events is the hypoxia/reoxygenation phenomenon.

  15. Influence of restricted vision and knee joint range of motion on gait properties during level walking and stair ascent and descent.

    PubMed

    Demura, Tomohiro; Demura, Shin-ich

    2011-01-01

    Because elderly individuals experience marked declines in various physical functions (e.g., vision, joint function) simultaneously, it is difficult to clarify the individual effects of these functional declines on walking. However, by imposing vision and joint function restrictions on young men, the effects of these functional declines on walking can be clarified. The authors aimed to determine the effect of restricted vision and range of motion (ROM) of the knee joint on gait properties while walking and ascending or descending stairs. Fifteen healthy young adults performed level walking and stair ascent and descent during control, vision restriction, and knee joint ROM restriction conditions. During level walking, walking speed and step width decreased, and double support time increased significantly with vision and knee joint ROM restrictions. Stance time, step width, and walking angle increased only with knee joint ROM restriction. Stance time, swing time, and double support time were significantly longer in level walking, stair descent, and stair ascent, in that order. The effects of vision and knee joint ROM restrictions were significantly larger than the control conditions. In conclusion, vision and knee joint ROM restrictions affect gait during level walking and stair ascent and descent. This effect is marked in stair ascent with knee joint ROM restriction.

  16. Effect of the Initial Vortex Size on Intensity Change in the WRF-ROMS Coupled Model

    NASA Astrophysics Data System (ADS)

    Zhao, Xiaohui; Chan, Johnny C. L.

    2017-12-01

    Numerous studies have demonstrated that the tropical cyclone (TC) induced sea surface temperature (SST) cooling strongly depends on the preexisting oceanic condition and TC characteristics. However, very few focused on the correlation of SST cooling and the subsequent intensity with TC size. Therefore, a series of idealized numerical experiments are conducted using the Weather Research Forecasting (WRF) model coupled with the Regional Ocean Model System (ROMS) model to understand how the vortex size is related to SST cooling and subsequent intensity changes of a stationary TC-like vortex. In the uncoupled experiments, the radius of maximum wind (RMW) and size (radius of gale-force wind (R17)) both depend on the initial size within the 72 h simulation. The initially small vortex is smaller than the medium and large vortices throughout its life cycle and is the weakest. In other words, thermodynamic processes do not contribute as much to the R17 change as the dynamic processes proposed (e.g., angular momentum transport) in previous studies. In the coupled experiments, the area-averaged SST cooling induced by medium and large TCs within the inner-core region is comparable due to the similar surface winds and thus mixing in the ocean. Although a stronger SST cooling averaged within a larger region outside the inner-core is induced by the larger TC, the intensity of the larger TC is more intense. This is because that the enthalpy flux in the inner-core region is higher in the larger TC than that in the medium and small TCs.

  17. Investigation of hypoxia off the Changjiang Estuary using a coupled model of ROMS-CoSiNE

    NASA Astrophysics Data System (ADS)

    Zhou, Feng; Chai, Fei; Huang, Daji; Xue, Huijie; Chen, Jianfang; Xiu, Peng; Xuan, Jiliang; Li, Jia; Zeng, Dingyong; Ni, Xiaobo; Wang, Kui

    2017-12-01

    The cause for large variability of hypoxia off the Changjiang Estuary has not been well understood partly due to various nutrient sources and complex physical-biological processes involved. The Regional Ocean Modeling Systems (ROMS) coupled with Carbon, Silicate and Nitrogen Ecosystem (CoSiNE) was used to investigate the 2006 hypoxia in the East China Sea, the largest hypoxia ever recorded. The model performance was evaluated comprehensively by comparing a suite of quantitative metrics, procedures and spatiotemporal patterns between the simulated results and observed data. The simulated results are generally consistent with the observations and are capable of reproducing the development of hypoxia and the observed vertical profiles of dissolved oxygen. Event-scale reduction of hypoxia occurred during the weakening of stratification in mid-July and mid-September, due to strong stirring caused by tropical storms or strong northerly wind. Change in wind direction altered the pathway of Changjiang Diluted Water and consequently caused variation in hypoxic location. Increase in river discharge led to an expansion of hypoxic water during the summer monsoon. Sensitivity analysis suggested that the hypoxia extent was affected by the change in nutrient concentration of the Changjiang as well as that of the Kuroshio. Sensitivity analysis also suggested the importance of sediment oxygen consumption to the size of the hypoxic zone. These results demonstrate that a prognostic 3D model is useful for investigating the highly variable hypoxia, with comprehensive considerations of multiple factors related to both physical and biological processes from the estuary to the shelf break of the East China Sea.

  18. Dynamical significance of tides over the Bay of Bengal

    NASA Astrophysics Data System (ADS)

    Bhagawati, Chirantan; Pandey, Suchita; Dandapat, Sumit; Chakraborty, Arun

    2018-06-01

    Tides play a significant role in the ocean surface circulations and vertical mixing thereby influencing the Sea Surface Temperatures (SST) as well. This, in turn, plays an important role in the global circulation when used as a lower boundary condition in a global atmospheric general circulation model. Therefore in the present study, the dynamics of tides over the Bay of Bengal (BoB) is investigated through numerical simulations using a high resolution (1/12°) Regional Ocean Modeling System (ROMS). Based on statistical analysis it is observed that incorporation of explicit tidal forcing improves the model performance in simulating the basin averaged monthly surface circulation features by 64% compared to the simulation without tides. The model simulates also Mixed Layer Depth (MLD) and SST realistically. The energy exchange between tidal oscillations and eddies leads to redistribution of surface kinetic energy density with a net decrease of 0.012 J m-3 in the western Bay and a net increase of 0.007 J m-3 in the eastern Bay. The tidal forcing also affects the potential energy anomaly and vertical mixing thereby leading to a fall in monthly MLD over the BoB. The mixing due to tides leads to a subsequent reduction in monthly SST and a corresponding reduction in surface heat exchange. These results from the numerical simulation using ROMS reveal that tides have a significant influence over the air-sea heat exchange which is the most important parameter for prediction of Tropical Cyclone frequency and its future variability over the BoB.

  19. Guide to listing references.

    DOT National Transportation Integrated Search

    2005-01-01

    The introduction of listing references. It introduces the reference of printed sources, CD-ROMs, websites, unpublished papers and program manuals, tapes, or other documentation for models. Meanwhile, it describes some examples to use Chicago Manual o...

  20. Analytical performances of d-ROMs test and BAP test in canine plasma. Definition of the normal range in healthy Labrador dogs.

    PubMed

    Pasquini, A; Luchetti, E; Marchetti, V; Cardini, G; Iorio, E L

    2008-02-01

    An high level of ROS (Reactive Oxygen Species), due to an increased production of oxidant species and/or a decreased efficacy of antioxidant system, can lead to oxidative stress, an emerging health risk factor involved in the aging and in many diseases, including inflammatory, infectious and degenerative disorders, either in humans or in animals. In the last years some assays panels have been developed to globally evaluate the oxidative balance by means of the concomitant assessment of ROS production and antioxidant system capability. In this report, the validation trials of d-ROMs (Reactive Oxygen Metabolites- derived compounds) and BAP (Biological Antioxidant Potential) tests in canine specie are described and also the specific referral ranges are calculated in a Labrador population. The results of linearity, precision and accuracy trials show that both tests exhibit good to excellent analytical performances. The possibility of measuring oxidative stress in vivo with simple, cheap and accurate tests, d-ROMs test and BAP test, provides for the veterinarians a very suitable tool to monitor oxidative stress and to correctly choice of eventual antioxidant supplementations in diseases proven related to oxidative stress in animals and particularly in dogs. Further studies will be useful to confirm this possibility.

Top