Sample records for system significant differences

  1. The Impact of National Cultural Differences on Nurses' Acceptance of Hospital Information Systems.

    PubMed

    Lin, Hsien-Cheng

    2015-06-01

    This study aims to explore the influence of national cultural differences on nurses' perceptions of their acceptance of hospital information systems. This study uses the perspective of Technology Acceptance Model; national cultural differences in terms of masculinity/femininity, individualism/collectivism, power distance, and uncertainty avoidance are incorporated into the Technology Acceptance Model as moderators, whereas time orientation is a control variable on hospital information system acceptance. A quantitative research design was used in this study; 261 participants, US and Taiwan RNs, all had hospital information system experience. Data were collected from November 2013 to February 2014 and analyzed using a t test to compare the coefficients for each moderator. The results show that individualism/collectivism, power distance, and uncertainty avoidance all exhibit significant difference on hospital information system acceptance; however, both masculinity/femininity and time orientation factors did not show significance. This study verifies that national cultural differences have significant influence on nurses' behavioral intention to use hospital information systems. Therefore, hospital information system providers should emphasize the way in which to integrate different technological functions to meet the needs of nurses from various cultural backgrounds.

  2. Assessment of apical transportation caused by nickel-titanium rotary systems with full rotation and reciprocating movements using extracted teeth and resin blocks with simulated root canals: A comparative study.

    PubMed

    Alrahabi, M; Zafar, M S

    2018-06-01

    : We compared apical transportation in the WaveOne and ProTaper Next systems, which are rotary nickel-titanium systems with reciprocating and continuous rotation movements, respectively, using manual measurements obtained from resin blocks with simulated root canals and double digital radiographs of extracted teeth. : We used 30 resin blocks with simulated root canals and 30 extracted teeth for this study. The same endodontist performed root canal shaping using the WaveOne or ProTaper Next system. We assessed apical transportation by measuring the amounts (in mm) of material lost 1 mm from the apical foramen in the resin blocks and by using double digital radiography for the extracted teeth. Significant differences between groups were assessed using t-tests. P < 0.05 was considered statistically significant. : The amount of apical transportation differed significantly between the two systems when resin blocks were used for assessment (P < 0.05), but there were no significant differences when extracted teeth were used (P < 0.05). In the current study, there was no significant difference in apical transportation between natural teeth prepared using WaveOne and those prepared using ProTaper Next. However, significant differences were observed between the two systems with resin blocks. These findings indicate that the use of resin blocks is not an accurate method for apical transportation evaluation.

  3. Effect of production system and flock age on eggshell and egg internal quality measurements.

    PubMed

    Samiullah, Sami; Omar, Amal Saleh; Roberts, Juliet; Chousalkar, Kapil

    2017-01-01

    Egg quality was measured in eggs from different flocks that were reared together and then allocated to different production systems. Eggs were processed for measurements of eggshell and egg internal quality variables, scoring of ultrastructural mammillary layer features, completeness of cuticle cover, and protoporphyrin IX (PP IX) quantification. There was a significant main effect (P < 0.05) of production system on shell reflectivity, egg weight, and egg internal quality and significant effects of flock age on most measurements. The mammillary layer ultrastructural variables showed no clear relationship with production system and flock age. However, there was a significant interaction between production system and flock age for mammillary cap, early and late fusions. Cuticle cover ([Formula: see text]), was significantly higher in barn eggs (19.20), followed by free range (17.57), and cage eggs (15.99). Completeness of cuticle cover was significantly higher in eggs from the 44 week old flock than for 64 week and 73 week old flocks. For eggshells with cuticle intact, there was a significant main effect of both production system and flock age, and significant interaction between the two, for shell reflectivity, L*a*b* values and amount of PP IX. For PP IX, when this difference was calculated for the cuticle alone, there were no statistically significant differences. In 1 g of shell with and without cuticle, there was more PP IX in cage eggs (9.49 × 10 -8 , 7.90 × 10 -8  mM) followed by free range (8.24 × 10 -8 , 6.90 × 10 -8  mM), and barn eggs (8.64 × 10 -8 , 7.28 × 10 -8  mM). Similar trends were recorded for the amount of PP IX in 1 g of cuticle, but the difference was not statistically significant. The amount of PP IX decreased significantly with increasing flock age. Comparing the cage and barn production systems at 68 week of flock age, there was no difference for the amount of PP IX in shell with or without cuticle, or in the cuticle alone. Eggs from the cage production system were darker in color and contained more PP IX mainly within the calcareous part of the shell. For the barn production system, the completeness of cuticle cover was higher and egg weight generally lower. © 2016 Poultry Science Association Inc.

  4. Optical properties of current ceramics systems for laminate veneers.

    PubMed

    Bagis, Bora; Turgut, Sedanur

    2013-08-01

    Full-ceramic systems can be produced by different techniques (layering, heatpressing, CAD/CAM) and have various compositions with different crystalline contents that may affect the optical properties of laminate restorations. A total of 60 specimens were prepared from e.max Press, e.max CAD, Empress Esthetic, e.max Ceram, Inline, and ZirPress systems (A1 shade; diameter 10mm; thickness 0.5 ± 0.05mm). The L*, a*, and b* values, chroma and translucency (TP) of each system were recorded before and after ageing. The statistical analyses were performed by ANOVA, Tukey's tests and the paired sample t-test (p<0.05). The L* value of the shade guide was significantly different from those of the full-ceramic systems; however, there were no significant differences between the a* values of Ceram, Esthetic, Inline and Zirpress. There were significant differences between the b* values of the shade guide compared with the full-ceramics except for e.max Press. The L* values decreased, and the a* and b* values increased after the ageing process for all groups. There were no significant differences between the ΔE values of the ceramic systems (p>0.05). The TP values decreased, and the chroma value increased significantly after the ageing process (p>0.05). The chroma of the shade guide was found to be the highest. None of the full-ceramic systems was able to match the color of the shade guide. The chemical structures of the ceramic systems were more effective for determining the optical parameters than the fabrication techniques. Ageing caused full-ceramics to become more opaque, darker, reddish and yellowish. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Analytic versus systemic group therapy for women with a history of child sexual abuse: 1-year follow-up of a randomized controlled trial.

    PubMed

    Elkjaer, Henriette; Kristensen, Ellids; Mortensen, Erik L; Poulsen, Stig; Lau, Marianne

    2014-06-01

    This randomized prospective study examines durability of improvement in general symptomatology, psychosocial functioning and interpersonal problems, and compares the long-term efficacy of analytic and systemic group psychotherapy in women 1 year after completion of treatment for childhood sexual abuse. Women (n = 106) randomly assigned to analytic or systemic psychotherapy completed the Symptom Checklist-90-R, Global Assessment of Functioning, Global Life Quality, Registration Chart Questionnaire, and Flashback Registration at pre-treatment, post-treatment, and at a 1-year follow-up. Post-treatment gains were significant for both treatment modalities on all measures, but significantly larger after systemic therapy. Significant treatment response was maintained 1-year post-treatment, but different trajectories were observed: 1 year after treatment completion, improvements for analytic therapy were maintained, whereas they decreased after systemic therapy, resulting in no statistically significant difference in gains between the groups at the 1-year follow-up. Despite maintaining significant gains, more than half of the patients remained above cut-off for caseness concerning general symptomatology at post-treatment and at 1-year follow-up. The findings stress the importance of long-term follow-up data in effect studies. Different trajectories were associated with the two treatments, but improvement in the two treatment groups did not differ significantly at the 1-year follow-up. Implications of the difference in trajectories for treatment planning are discussed. Both analytic and systemic group therapy proved efficient in improving general symptomatology, psychosocial functioning, and interpersonal problems in women with a history of CSA and gains were maintained at a 1-year follow-up. Despite maintaining statistically significant gains at the 1-year follow-up, 54% of the patients remained above the cut-off for caseness with respect to general symptomatology, which may indicate a need for further treatment. Different pre-post follow-up treatment trajectories were observed between the two treatment modalities. Thus, while systemic group therapy showed a significantly better outcome immediately after termination, gains in the systemic treatment group decreased during follow-up, while gains were maintained during follow-up in analytic group therapy. © 2013 The British Psychological Society.

  6. Comparison of growth factor and platelet concentration from commercial platelet-rich plasma separation systems.

    PubMed

    Castillo, Tiffany N; Pouliot, Michael A; Kim, Hyeon Joo; Dragoo, Jason L

    2011-02-01

    Clinical studies claim that platelet-rich plasma (PRP) shortens recovery times because of its high concentration of growth factors that may enhance the tissue repair process. Most of these studies obtained PRP using different separation systems, and few analyzed the content of the PRP used as treatment. This study characterized the composition of single-donor PRP produced by 3 commercially available PRP separation systems. Controlled laboratory study. Five healthy humans donated 100 mL of blood, which was processed to produce PRP using 3 PRP concentration systems (MTF Cascade, Arteriocyte Magellan, Biomet GPS III). Platelet, white blood cell (WBC), red blood cell, and fibrinogen concentrations were analyzed by automated systems in a clinical laboratory, whereas ELISA determined the concentrations of platelet-derived growth factor αβ and ββ (PDGF-αβ, PDGF-ββ), transforming growth factor β1 (TGF-β1), and vascular endothelial growth factor (VEGF). There was no significant difference in mean PRP platelet, red blood cell, active TGF-β1, or fibrinogen concentrations among PRP separation systems. There was a significant difference in platelet capture efficiency. The highest platelet capture efficiency was obtained with Cascade, which was comparable with Magellan but significantly higher than GPS III. There was a significant difference among all systems in the concentrations of WBC, PDGF-αβ, PDGF-ββ, and VEGF. The Cascade system concentrated leukocyte-poor PRP, compared with leukocyte-rich PRP from the GPS III and Magellan systems. The GPS III and Magellan concentrate leukocyte-rich PRP, which results in increased concentrations of WBCs, PDGF-αβ, PDGF-ββ, and VEGF as compared with the leukocyte-poor PRP from Cascade. Overall, there was no significant difference among systems in the platelet concentration, red blood cell, active TGF-β1, or fibrinogen levels. Products from commercially available PRP separation systems produce differing concentrations of growth factors and WBCs. Further research is necessary to determine the clinical relevance of these findings.

  7. Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    PubMed

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-10-01

    Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes. A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales. Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures. The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment complaints with conventional dentures can possibly identify patient dissatisfaction with mandibular two-implant overdentures [corrected]. © 2010 Wiley Periodicals, Inc.

  8. Comparison of different finishing/polishing systems on surface roughness and gloss of resin composites.

    PubMed

    Antonson, Sibel A; Yazici, A Rüya; Kilinc, Evren; Antonson, Donald E; Hardigan, Patrick C

    2011-07-01

    The aim of this study was to compare four finishing/polishing systems (F/P) on surface roughness and gloss of different resin composites. A total of 40 disc samples (15 mm × 3 mm) were prepared from a nanofill - Filtek Supreme Plus (FS) and a micro-hybrid resin composite - Esthet-X (EX). Following 24h storage in 37°C water, the top surfaces of each sample were roughened using 120-grit sandpaper. Baseline measurements of surface roughness (Ra, μm) and gloss were recorded. Each composite group was divided into four F/P disk groups: Astropol[AP], Enhance/PoGo[EP], Sof-Lex[SL], and an experimental disk system, EXL-695[EXL] (n=5). The same operator finished/polished all samples. One sample from each group was evaluated under SEM. Another blinded-operator conducted postoperative measurements. Results were analysed by two-way ANOVA, two interactive MANOVA and Tukey's t-test (p<0.05). In surface roughness, the baseline of two composites differed significantly from each other whereas postoperatively there was no significance. The Sof-Lex F/P system provided the smoothest surface although there were no statistical significance differences between F/P systems (p>0.01). In gloss, FS composite with the EXL-695 system provided a significantly higher gloss (p<0.01). EX treated by Soflex revealed the least gloss (p<0.05). SEM images revealed comparable results for F/P systems but EX surfaces included more air pockets. Four different finishing/polishing systems provided comparable surface smoothness for both composites, whereas EXL with FS provided significantly higher gloss. SEM evaluations revealed that the EX surface contained more air pockets but F/P systems were compatible. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

    PubMed

    Mirzakouchaki, Behnam; Shirazi, Sajjad; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-02-01

    Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.

  10. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

    PubMed Central

    Mirzakouchaki, Behnam; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-01-01

    Background Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. Material and Methods 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. Results The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. Conclusions The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. PMID:26855704

  11. Seroprevalence of spotted fever group (SFG) rickettsiae infection in domestic ruminants in Khartoum State, Sudan.

    PubMed

    Eisawi, Nagwa M; Hassan, Dina A; Hussien, Mohammed O; Musa, Azza B; El Hussein, Abdel Rahim M

    2017-05-01

    Spotted fever group (SFG) rickettsiosis is caused by obligatory intracellular Gram-negative bacteria that belong to the genus Rickettsia . Ticks belonging to the family Ixodidae can act as vectors, reservoirs or amplifiers of SFG rickettsiae. This study was conducted to estimate the seroprevalence of SFG rickettsioses in cattle, sheep and goats from Khartoum State, Sudan. Blood samples were collected from a total of 600 animals (sheep, goats and cattle) from 32 different farms distributed in three locations in Khartoum State during the period January to December 2012. Sera were tested for antibodies against SFG rickettsiae using IFAT. The prevalence of seropositivity was 59.3% in sheep, 60.1% in goats and 64.4% in cattle. Season was significantly ( P <  0.05) associated with seroprevalence of SFG rickettsiae in cattle during winter. The SFG rickettsiae antibodies prevalence was significantly higher in female compared with male in sheep, but there were no significant differences between male and female in either cattle or goats. The prevalence was significantly higher in adult animals compared with young in both sheep and goats. With regard to management system, there was a significant difference in the prevalence in cattle raised in closed system compared with those raised in semi-intensive system. In contrast, there was significant difference in the seroprevalence of SFG in sheep where the prevalence was higher in the sheep raised in semi-intensive system compared with those raised in close system. There was no significant difference in the seroprevalence in goats with regard to management systems. The unexpected high prevalence of SFG rickettsia antibodies in domestic ruminants sera suggest that the veterinary and public health impact of these agents in Sudan need further evaluation especially in humans.

  12. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    PubMed

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  13. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.811). Similarly at L5/S1 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.981). At L4/L5 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.290). Similarly at L5/S1 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.523). As for radiation exposure, HELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  14. Alpha-synuclein levels in patients with multiple system atrophy: a meta-analysis.

    PubMed

    Yang, Fei; Li, Wan-Jun; Huang, Xu-Sheng

    2018-05-01

    This study evaluates the relationship between multiple system atrophy and α-synuclein levels in the cerebrospinal fluid, plasma and neural tissue. Literature search for relevant research articles was undertaken in electronic databases and study selection was based on a priori eligibility criteria. Random-effects meta-analyses of standardized mean differences in α-synuclein levels between multiple system atrophy patients and normal controls were conducted to obtain the overall and subgroup effect sizes. Meta-regression analyses were performed to evaluate the effect of age, gender and disease severity on standardized mean differences. Data were obtained from 11 studies involving 378 multiple system atrophy patients and 637 healthy controls (age: multiple system atrophy patients 64.14 [95% confidence interval 62.05, 66.23] years; controls 64.16 [60.06, 68.25] years; disease duration: 44.41 [26.44, 62.38] months). Cerebrospinal fluid α-synuclein levels were significantly lower in multiple system atrophy patients than in controls but in plasma and neural tissue, α-synuclein levels were significantly higher in multiple system atrophy patients (standardized mean difference: -0.99 [-1.65, -0.32]; p = 0.001). Percentage of male multiple system atrophy patients was significantly positively associated with the standardized mean differences of cerebrospinal fluid α-synuclein levels (p = 0.029) whereas the percentage of healthy males was not associated with the standardized mean differences of cerebrospinal fluid α-synuclein levels (p = 0.920). In multiple system atrophy patients, α-synuclein levels were significantly lower in the cerebrospinal fluid and were positively associated with the male gender.

  15. In Vitro Comparison of the Bond Strength between Ceramic Repair Systems and Ceramic Materials and Evaluation of the Wettability.

    PubMed

    Kocaağaoğlu, Hasan; Manav, Taha; Albayrak, Haydar

    2017-04-01

    When fracture of an all-ceramic restoration occurs, it can be necessary to repair without removing the restoration. Although there are many studies about the repair of metal-ceramic restorations, there are few about all-ceramic restorations. The aim of this study was to evaluate the shear bond strength between ceramic repair systems and esthetic core materials and to evaluate the wettability of all-ceramic core materials. Disk-like specimens (N = 90) made of three dental ceramic infrastructure materials (zirconia ceramic, alumina ceramic, glass ceramic) were polished with silicon carbide paper, prepared for bonding (abrasion with 30 μm diamond rotary cutting instrument). Thirty specimens of each infrastructure were obtained. Each infrastructure group was divided into three subgroups; they were bonded using 3 repair systems: Bisco Intraoral Repair Kit, Cimara & Cimara Zircon Repair System, and Clearfil Repair System. After 1200 thermocycles, shear bond strength was measured in a universal testing machine at a 0.5 mm/min crosshead speed. In addition, the contact angle values of the infrastructures after surface treatments were examined for wettability. Data were analyzed by using ANOVA and Tukey post hoc tests. Although there were no significant differences among the repair systems (p > 0.05) in the glass ceramic and zirconia groups, a significant difference was found among the repair systems in alumina infrastructure (p < 0.001). There were no statistically significant differences among the infrastructures (p > 0.05); however, a statistically significant difference was found among the repair systems (p < 0.05). No difference was found among the infrastructures and repair systems in terms of contact angle values. Cimara & Cimara Zircon Repair System had higher bond strength values than the other repair systems. Although no difference was found among the infrastructures and repair systems, contact wettability angle was decreased by surface treatments compared with polished surfaces. © 2015 by the American College of Prosthodontists.

  16. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

    PubMed Central

    Shokri, Abbas; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-01-01

    Purpose This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. Results In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes (P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results. PMID:29581947

  17. Intercollegiate Athletics in Canada and the United States: Differences in Access, Quality, and Funding

    ERIC Educational Resources Information Center

    Geiger, Natalie M.

    2013-01-01

    Despite the fact that both the Canadian and American intercollegiate athletic leagues are highly competitive, there are significant differences between the two intercollegiate athletic systems, which may produce different experiences for student-athletes enrolled in each system. The differences between the two systems are related to the…

  18. Quantitative evaluation of apically extruded debris with different single-file systems: Reciproc, F360 and OneShape versus Mtwo.

    PubMed

    Bürklein, S; Benten, S; Schäfer, E

    2014-05-01

    To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05). Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Comparison of heuristic and cognitive walkthrough usability evaluation methods for evaluating health information systems.

    PubMed

    Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes

    2017-04-01

    There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P  = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P  = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P  = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P  < .0001). The average severity of problems identified using CW was significantly higher than that of HE ( P  < .0001). This study showed that HE and CW do not differ significantly in terms of the number of usability problems identified, but they differ based on the severity of problems and the coverage of some usability attributes. The results suggest that CW would be the preferred method for evaluating systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  20. The systemizing quotient: an investigation of adults with Asperger syndrome or high-functioning autism, and normal sex differences.

    PubMed Central

    Baron-Cohen, Simon; Richler, Jennifer; Bisarya, Dheraj; Gurunathan, Nhishanth; Wheelwright, Sally

    2003-01-01

    Systemizing is the drive to analyse systems or construct systems. A recent model of psychological sex differences suggests that this is a major dimension in which the sexes differ, with males being more drawn to systemize than females. Currently, there are no self-report measures to assess this important dimension. A second major dimension of sex differences is empathizing (the drive to identify mental states and respond to these with an appropriate emotion). Previous studies find females score higher on empathy measures. We report a new self-report questionnaire, the Systemizing Quotient (SQ), for use with adults of normal intelligence. It contains 40 systemizing items and 20 control items. On each systemizing item, a person can score 2, 1 or 0, so the SQ has a maximum score of 80 and a minimum of zero. In Study 1, we measured the SQ of n = 278 adults (114 males, 164 females) from a general population, to test for predicted sex differences (male superiority) in systemizing. All subjects were also given the Empathy Quotient (EQ) to test if previous reports of female superiority would be replicated. In Study 2 we employed the SQ and the EQ with n = 47 adults (33 males, 14 females) with Asperger syndrome (AS) or high-functioning autism (HFA), who are predicted to be either normal or superior at systemizing, but impaired at empathizing. Their scores were compared with n = 47 matched adults from the general population in Study 1. In Study 1, as predicted, normal adult males scored significantly higher than females on the SQ and significantly lower on the EQ. In Study 2, again as predicted, adults with AS/HFA scored significantly higher on the SQ than matched controls, and significantly lower on the EQ than matched controls. The SQ reveals both a sex difference in systemizing in the general population and an unusually strong drive to systemize in AS/HFA. These results are discussed in relation to two linked theories: the 'empathizing-systemizing' (E-S) theory of sex differences and the extreme male brain (EMB) theory of autism. PMID:12639333

  1. Commercial Separation Systems Designed for Preparation of Platelet-Rich Plasma Yield Differences in Cellular Composition.

    PubMed

    Degen, Ryan M; Bernard, Johnathan A; Oliver, Kristin S; Dines, Joshua S

    2017-02-01

    The role of platelet-rich plasma (PRP) in the treatment of sport-related injuries is unclear, largely due to the heterogeneity of clinical results. This may relate to compositional differences in PRP from different separation systems. This study aims to compare the composition of PRP produced with five different commercially available systems, focusing on cellular concentrations and pH. Seven donors (41 ± 12 years) provided blood for PRP preparation using five systems (Arthrex Angel, Emcyte Genesis CS, Arteriocyte Magellan, Harvest SmartPrep, and Biomet GPS III). Post processing, cellular composition was measured including platelets (PLT), white blood cells (WBC), neutrophils (NE), and red blood cells (RBC), as well as pH. Platelet concentration and capture efficiency were similar between systems, except the Angel 7% preparation had a greater concentration than Genesis CS (2310 ± 524 vs. 1129 ± 264 k/μL). WBC concentration was variable between systems; however, significant differences were only found between the Angel 2% and GPS III preparations (11.0 ± 4.5, 27.3 ± 7.1 k/μL). NE concentration was significantly lower in the Angel 2% and 7% preparations compared with GPS III (0.6 ± 0.6 and 1.8 ± 1.3 k/μL vs. 9.4 ± 7.0 k/μL). RBC concentration was highest in SmartPrep (3.2 ± 0.6 M/μL) and Genesis CS systems (3.1 ± 0.6 M/μL) compared with all other systems (≤1.1 ± 1.2 M/μL). Finally, pH was significantly lower with the SmartPrep system (6.95 ± 0.06) compared with all others (≥7.26 ± 0.06). Aside from platelet concentration and capture efficiency, significant compositional differences were identified between preparation systems. Caution should be employed when interpreting clinical results of studies utilizing PRP, as the role of compositional differences and their effect on outcome are unknown. Further study is necessary to determine the clinical significance of these differences.

  2. Computer-Aided Diagnosis System for Alzheimer's Disease Using Different Discrete Transform Techniques.

    PubMed

    Dessouky, Mohamed M; Elrashidy, Mohamed A; Taha, Taha E; Abdelkader, Hatem M

    2016-05-01

    The different discrete transform techniques such as discrete cosine transform (DCT), discrete sine transform (DST), discrete wavelet transform (DWT), and mel-scale frequency cepstral coefficients (MFCCs) are powerful feature extraction techniques. This article presents a proposed computer-aided diagnosis (CAD) system for extracting the most effective and significant features of Alzheimer's disease (AD) using these different discrete transform techniques and MFCC techniques. Linear support vector machine has been used as a classifier in this article. Experimental results conclude that the proposed CAD system using MFCC technique for AD recognition has a great improvement for the system performance with small number of significant extracted features, as compared with the CAD system based on DCT, DST, DWT, and the hybrid combination methods of the different transform techniques. © The Author(s) 2015.

  3. Comparison of Precision between Optical and Electromagnetic Navigation Systems in Total Knee Arthroplasty

    PubMed Central

    Rhee, Seung Joon; Park, Shi Hwan; Cho, He Myung

    2014-01-01

    Purpose The purpose of this study is to compare and analyze the precision of optical and electromagnetic navigation systems in total knee arthroplasty (TKA). Materials and Methods We retrospectively reviewed 60 patients who underwent TKA using an optical navigation system and 60 patients who underwent TKA using an electromagnetic navigation system from June 2010 to March 2012. The mechanical axis that was measured on preoperative radiographs and by the intraoperative navigation systems were compared between the groups. The postoperative positions of the femoral and tibial components in the sagittal and coronal plane were assessed. Results The difference of the mechanical axis measured on the preoperative radiograph and by the intraoperative navigation systems was 0.6 degrees more varus in the electromagnetic navigation system group than in the optical navigation system group, but showed no statistically significant difference between the two groups (p>0.05). The positions of the femoral and tibial components in the sagittal and coronal planes on the postoperative radiographs also showed no statistically significant difference between the two groups (p>0.05). Conclusions In TKA, both optical and electromagnetic navigation systems showed high accuracy and reproducibility, and the measurements from the postoperative radiographs showed no significant difference between the two groups. PMID:25505703

  4. Microleakage of teeth restored with different adhesive dowel systems: an in vitro study.

    PubMed

    Sarı, Tuğrul; Özyesil, Atilla G

    2014-01-01

    Commercial fiber-reinforced dowel systems are marketed as having better adhesion and sealing ability than conventional metallic dowel systems. The aim of this in vitro study was to evaluate the microleakage of teeth restored with nine dowel systems. Ninety mandibular second premolar teeth were decoronated, and nine homogenous groups were composed of ten teeth each. Root canal and dowel space preparations were made, and eight fiber-reinforced composite dowel systems and one stainless steel dowel system were used to fabricate dowel restorations. Microleakage measurements of the restored teeth were made with a modified fluid filtration method, and data were collected. One sample Kolmogorov-Smirnov, one-way ANOVA, and Tukey-HSD tests were performed on the relative microleakage data of the groups. Microleakage values were reported relative to those for teeth with unfilled canals. The highest and lowest relative microleakage values were recorded for the metallic Parapost (7.06 × 10(-4) %) and fiber-reinforced Everstick (3.55 × 10(-4) %) groups, respectively. Significant differences in relative microleakage between the fiber-reinforced dowels and stainless steel dowels were observed. Significant differences among the fiber-reinforced dowel groups were observed as well. The sealing ability of all fiber-reinforced composite dowels is not better than that of stainless steel dowels, and there are significant differences among different fiber-reinforced dowel systems as well. Differences among commercial dowel systems must be taken into consideration when making a selection. © 2013 by the American College of Prosthodontists.

  5. White matter lesions and brain atrophy in systemic lupus erythematosus patients: correlation to cognitive dysfunction in a cohort of systemic lupus erythematosus patients using different definition models for neuropsychiatric systemic lupus erythematosus.

    PubMed

    Cannerfelt, B; Nystedt, J; Jönsen, A; Lätt, J; van Westen, D; Lilja, A; Bengtsson, A; Nilsson, P; Mårtensson, J; Sundgren, P C

    2018-06-01

    Aim The aim of this study was to evaluate the extent of white matter lesions, atrophy of the hippocampus and corpus callosum, and their correlation with cognitive dysfunction (CD), in patients diagnosed with systemic lupus erythematosus (SLE). Methods Seventy SLE patients and 25 healthy individuals (HIs) were included in the study. To evaluate the different SLE and neuropsychiatric SLE (NPSLE) definition schemes, patients were grouped both according to the American College of Rheumatology (ACR) definition, as well as the more stringent ACR-Systemic Lupus International Collaborating Clinics definition. Patients and HIs underwent a 3 Tesla brain MRI and a standardized neuropsychological test. MRI data were evaluated for number and volume of white matter lesions and atrophy of the hippocampus and corpus callosum. Differences between groups and subgroups were evaluated for significance. Number and volume of white matter lesions and atrophy of the hippocampus and corpus callosum were correlated to cognitive dysfunction. Results The total volume of white matter lesions was significantly larger in SLE patients compared to HIs ( p = 0.004). However, no significant differences were seen between the different SLE subgroups. Atrophy of the bilateral hippocampus was significantly more pronounced in patients with NPSLE compared to those with non-NPSLE (right: p = 0.010; left p = 0.023). Significant negative correlations between cognitive test scores on verbal memory and number and volume of white matter lesions were present. Conclusion SLE patients have a significantly larger volume of white matter lesions on MRI compared to HIs and the degree of white matter lesion volume correlates to cognitive dysfunction, specifically to verbal memory. No significant differences in the number or volume of white matter lesions were identified between subgroups of SLE patients regardless of the definition model used.

  6. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    PubMed

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  7. Asymptomatic corneal staining associated with the use of balafilcon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen.

    PubMed

    Jones, Lyndon; MacDougall, Nancy; Sorbara, L Gina

    2002-12-01

    To compare subjective symptoms and signs in a group of individuals who wear silicone-hydrogel lenses on a daily wear basis while they sequentially used two differing care regimens. Fifty adapted soft-lens wearers were fitted with a silicone-hydrogel lens material (PureVision, Bausch & Lomb). The lenses were worn on a daily wear basis for two consecutive 1-month periods, during which the subjects used either a Polyquad (polyquaternium-1) -based system or a polyaminopropyl biguanide (PHMB) -based system, using a double-masked, randomized, crossover experimental design. Significant levels of relatively asymptomatic corneal staining were observed when subjects used the PHMB-based system, with 37% of subjects demonstrating a level of staining consistent with a classical solution-based toxicity reaction. Only 2% of the subjects exhibited such staining when using the Polyquad-based system. These results were significantly different (p < 0.001). Significant symptoms were not correlated with the degree of staining, with no differences in lens comfort or overall preference being reported between the regimens (p = NS). The only statistically significant difference in symptoms related to minor differences in stinging after lens insertion being reported, with the Polyquad-based system demonstrating less stinging (p < 0.008). Practitioners who fit silicone-hydrogel contact lenses on a daily wear basis should be wary of the potential for certain PHMB-containing multipurpose care systems to invoke corneal staining. Switching to non-PHMB based regimens will eliminate this complication in most instances.

  8. Long-term effects of user preference-oriented recommendation method on the evolution of online system

    NASA Astrophysics Data System (ADS)

    Shi, Xiaoyu; Shang, Ming-Sheng; Luo, Xin; Khushnood, Abbas; Li, Jian

    2017-02-01

    As the explosion growth of Internet economy, recommender system has become an important technology to solve the problem of information overload. However, recommenders are not one-size-fits-all, different recommenders have different virtues, making them be suitable for different users. In this paper, we propose a novel personalized recommender based on user preferences, which allows multiple recommenders to exist in E-commerce system simultaneously. We find that output of a recommender to each user is quite different when using different recommenders, the recommendation accuracy can be significantly improved if each user is assigned with his/her optimal personalized recommender. Furthermore, different from previous works focusing on short-term effects on recommender, we also evaluate the long-term effect of the proposed method by modeling the evolution of mutual feedback between user and online system. Finally, compared with single recommender running on the online system, the proposed method can improve the accuracy of recommendation significantly and get better trade-offs between short- and long-term performances of recommendation.

  9. [Comparation on Haversian system between human and animal bones by imaging analysis].

    PubMed

    Lu, Hui-Ling; Zheng, Jing; Yao, Ya-Nan; Chen, Sen; Wang, Hui-Pin; Chen, Li-Xian; Guo, Jing-Yuan

    2006-04-01

    To explore the differences in Haversian system between human and animal bones through imaging analysis and morphology description. Thirty-five slices grinding from human being as well as dog, pig, cow and sheep bones were observed to compare their structure, then were analysed with the researchful microscope. Plexiform bone or oeston band was not found in human bones; There were significant differences in the shape, size, location, density of Haversian system, between human and animal bones. The amount of Haversian lamella and diameter of central canal in human were the biggest; Significant differences in the central canal diameter and total area percentage between human and animal bones were shown by imaging analysis. (1) Plexiform bone and osteon band could be the exclusive index in human bone; (2) There were significant differences in the structure of Haversian system between human and animal bones; (3) The percentage of central canals total area was valuable in species identification through imaging analysis.

  10. [Reliability of iWitness photogrammetry in maxillofacial application].

    PubMed

    Jiang, Chengcheng; Song, Qinggao; He, Wei; Chen, Shang; Hong, Tao

    2015-06-01

    This study aims to test the accuracy and precision of iWitness photogrammetry for measuring the facial tissues of mannequin head. Under ideal circumstances, the 3D landmark coordinates were repeatedly obtained from a mannequin head using iWitness photogrammetric system with different parameters, to examine the precision of this system. The differences between the 3D data and their true distance values of mannequin head were computed. Operator error of 3D system in non-zoom and zoom status were 0.20 mm and 0.09 mm, and the difference was significant (P 0.05). Image captured error of 3D system was 0.283 mm, and there was no significant difference compared with the same group of images (P>0.05). Error of 3D systen with recalibration was 0.251 mm, and the difference was not statistically significant compared with image captured error (P>0.05). Good congruence was observed between means derived from the 3D photos and direct anthropometry, with difference ranging from -0.4 mm to +0.4 mm. This study provides further evidence of the high reliability of iWitness photogrammetry for several craniofacial measurements, including landmarks and inter-landmark distances. The evaluated system can be recommended for the evaluation and documentation of the facial surface.

  11. Typologies in Comparative Vocational Education: Existing Models and a New Approach

    ERIC Educational Resources Information Center

    Pilz, Matthias

    2016-01-01

    The ways in which vocational education and training (VET) systems are structured vary significantly from country to country, both because different countries have different objectives for their VET systems and because VET is differently embedded within the education and labour market systems of any individual country. International research in…

  12. Apical extrusion of debris during the preparation of oval root canals: a comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file.

    PubMed

    Kfir, Anda; Moza-Levi, Rotem; Herteanu, Moran; Weissman, Amir; Wigler, Ronald

    2018-03-01

    The purpose of this study was to assess the amount of apically extruded debris during the preparation of oval canals with either a rotary file system supplemented by the XP-endo Finisher file or a full-sequence self-adjusting file (SAF) system. Sixty mandibular incisors were randomly assigned to two groups: group A: stage 1-glide path preparation with Pre-SAF instruments. Stage 2-cleaning and shaping with SAF. Group B: stage 1-glide path preparation with ProGlider file. Stage 2-cleaning and shaping with ProTaper Next system. Stage 3-Final cleaning with XP-endo Finisher file. The debris extruded during each of the stages was collected, and the debris weights were compared between the groups and between the stages within the groups using t tests with a significance level set at P < 0.05. The complete procedure for group B resulted in significantly more extruded debris compared to group A. There was no significant difference between the stages in group A, while there was a significant difference between stage 2 and stages 1 and 3 in group B, but no significant difference between stages 1 and 3. Both instrumentation protocols resulted in extruded debris. Rotary file followed by XP-endo Finisher file extruded significantly more debris than a full-sequence SAF system. Each stage, in either procedure, had its own contribution to the extrusion of debris. Final preparation with XP-endo Finisher file contributes to the total amount of extruded debris, but the clinical relevance of the relative difference in the amount of apically extruded debris remains unclear.

  13. Recent Clinical Characteristics of Labors Using Three Japanese Systems of Midwife-Led Primary Delivery Care

    PubMed Central

    Suzuki, Shunji

    2016-01-01

    Objective. The objective of this study was to describe the recent clinical characteristics of labor using 3 systems of Japanese midwife-led primary delivery care, as follows: (1) those intending to give birth at home managed by midwives who do not belong to our hospital, (2) those planning to give birth in our hospital managed by the same midwives, and (3) those planning to give birth managed by midwives who belong to our hospital. Methods. A retrospective cohort study was performed. Results. There were no significant differences in the obstetric or neonatal outcomes among the 3 groups. The rate of transfers during labor with the system involving midwives belonging to our hospital was higher than those with the other 2 systems. In addition, the timing of transfers in the system with the midwives belonging to our hospital was earlier than with the other 2 systems. Among the 3 groups, there were no significant differences in the rate of the main 2 indications for transfers: fetal heart rate abnormality and failure to progress. Conclusion. There were no significant differences in perinatal outcomes among the 3 systems; however, there were some differences in the status of transfers to obstetric shared care. PMID:27034827

  14. Relationships of nuclear, architectural and International Federation of Gynecology and Obstetrics grading systems in endometrial cancer.

    PubMed

    Toptaş, Tayfun; Peştereli, Elif; Bozkurt, Selen; Erdoğan, Gülgün; Şimşek, Tayup

    2018-03-01

    To examine correlations among nuclear, architectural, and International Federation of Gynecology and Obstetrics (FIGO) grading systems, and their relationships with lymph node (LN) involvement in endometrioid endometrial cancer. Histopathology slides of 135 consecutive patients were reviewed with respect to tumor grade and LN metastasis. Notable nuclear atypia was defined as grade 3 nuclei. FIGO grade was established by raising the architectural grade (AG) by one grade when the tumor was composed of cells with nuclear grade (NG) 3. Correlations between the grading systems were analyzed using Spearman's rank correlation coefficients, and relationships of grading systems with LN involvement were assessed using logistic regression analysis. Correlation analysis revealed a significant and strongly positive relationship between FIGO and architectural grading systems (r=0.885, p=0.001); however, correlations of nuclear grading with the architectural (r=0.535, p=0.165) and FIGO grading systems (r=0.589, p=0.082) were moderate and statistically non-significant. Twenty-five (18.5%) patients had LN metastasis. LN involvement rates differed significantly between tumors with AG 1 and those with AG 2, and tumors with FIGO grade 1 and those with FIGO grade 2. In contrast, although the difference in LN involvement rates failed to reach statistical significance between tumors with NG 1 and those with NG 2, it was significant between NG 2 and NG 3 (p=0.042). Although all three grading systems were associated with LN involvement in univariate analyses, an independent relationship could not be established after adjustment for other confounders in multivariate analysis. Nuclear grading is significantly correlated with neither architectural nor FIGO grading systems. The differences in LN involvement rates in the nuclear grading system reach significance only in the setting of tumor cells with NG 3; however, none of the grading systems was an independent predictor of LN involvement.

  15. Genetic bottlenecks during systemic movement of Cucumber mosaic virus vary in different host plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Akhtar; Roossinck, Marilyn J., E-mail: mroossinck@noble.or

    2010-09-01

    Genetic bottlenecks are stochastic events that narrow variation in a population. We compared bottlenecks during the systemic infection of Cucumber mosaic virus (CMV) in four host plants. We mechanically inoculated an artificial population of twelve CMV mutants to young leaves of tomato, pepper, Nicotiana benthamiana, and squash. The inoculated leaves and primary and secondary systemically infected leaves were sampled at 2, 10, and 15 days post-inoculation. All twelve mutants were detected in all of the inoculated leaves. The number of mutants recovered from the systemically infected leaves of all host species was reduced significantly, indicating bottlenecks in systemic movement. Themore » recovery frequencies of a few of the mutants were significantly different in each host probably due to host-specific selective forces. These results have implications for the differences in virus population variation that is seen in different host plants.« less

  16. Epidemiology of systemic lupus erythematosus: an update.

    PubMed

    Stojan, George; Petri, Michelle

    2018-03-01

    Systemic lupus erythematosus (SLE) is the prototypical systemic autoimmune disease with a significant disease burden across the world among different ethnic, racial, and age groups. The pathophysiological understanding of SLE is constantly evolving and with it, the need for a better definition of the disease itself, for understanding the risk among the different affected populations, and for identifying the factors responsible for the damage accrual through the years. More accurate estimates of incidence and prevalence of SLE among different ethnicities and minority groups not only in the USA, but also in Europe, Middle East, and Asia have provided new insights into the disease burden around the world. Despite advances in treatment, mortality among SLE patients remains high with significant ethnic and geographic variations. Sex, race, and ethnicity significantly affect SLE incidence, prevalence, and mortality.

  17. Metabolomic profiling and sensorial quality of 'Golden Delicious', 'Liberty', 'Santana', and 'Topaz' apples grown using organic and integrated production systems.

    PubMed

    Vanzo, Andreja; Jenko, Mojca; Vrhovsek, Urska; Stopar, Matej

    2013-07-03

    Apple quality was investigated in the scab-resistant 'Liberty', 'Santana', and 'Topaz' cultivars and the scab-susceptible 'Golden Delicious' cultivar. Trees subjected to the same crop load were cultivated using either an organic (ORG) or an integrated production (IP) system. Physicochemical properties, phenolic content, and sensorial quality of fruit from both systems were compared. There were no significant differences in fruit mass, starch, and total soluble solid content (the latter was higher in ORG 'Liberty') between ORG and IP fruit, whereas significantly higher flesh firmness was found in ORG fruit (except no difference in 'Golden Delicious'). Significantly higher total phenolic content in ORG fruit was found in 'Golden Delicious', whereas differences in other cultivars were not significant. Targeted metabolomic profiling of multiple classes of phenolics confirmed the impact of the production system on the 'Golden Delicious' phenolic profile as higher levels of 4-hydroxybenzoic acid, neo- and chlorogenic acids, phloridzin, procyanidin B2+B4, -3-O-glucoside and -3-O-galactoside of quercetin, kaempferol-3-O-rutinoside, and rutin being found in ORG fruit. The results obtained suggested that scab resistance influenced the phenolic biosynthesis in relation to the agricultural system. Sensorial evaluation indicated significantly better flavor (except for 'Topaz') and better appearance of IP fruit.

  18. Comparison of the root canal debridement ability of two single file systems with a conventional multiple rotary system in long oval-shaped root canals: In vitro study.

    PubMed

    Khoshbin, Elham; Shokri, Abbas; Donyavi, Zakieh; Shahriari, Shahriar; Salehimehr, Golsa; Farhadian, Maryam; Kavandi, Zeinab

    2017-08-01

    This study sought to compare the root canal debridement ability of Neolix, Reciproc and ProTaper rotary systems in long oval-shaped root canals. Eighty five extracted single-rooted human teeth with long oval-shaped single root canals were selected and divided into three experimental groups(n=25) and one control group (n= 10). Root canals were filled with Vitapex radiopaque contrast medium and prepared with Neolix, Reciproc or ProTaper systems. The control group only received irrigation. Digital radiographs were obtained at baseline and postoperatively and subjected to digital subtraction. The percentage of reduction in contrast medium was quantified at 0-5 mm and 5-10 mm distances from the apex. The data were analyzed using one-way ANOVA and t-test. The mean percentage of the contrast medium removed was not significantly different in the 0-5mm segment among the three groups ( P =0.6). In the 5-10mm segment a significant difference was found in this regard among the ProTaper and Reciproc groups ( P =0.02) and the highest mean percentage of contrast medium was removed by ProTaper. But, difference between ProTaper and Neolix as well as Neolix and Reciproc was not significant. In Neolix ( P =0.024) and Reciproc ( P =0.002) systems, the mean percentage of the contrast medium removed from the 0-5mm segment was significantly greater than that in 5-10mm segment; however, this difference was not significant in ProTaper group ( P =0.069). Neolix single-file system may be a suitable alternative to ProTaper multiple-file system in debridement of long oval shaped canals. Key words: Root Canal Preparation, Debridement, Root Canal Therapy.

  19. Investigating the state-of-the-art in whole-body MR-based attenuation correction: an intra-individual, inter-system, inventory study on three clinical PET/MR systems.

    PubMed

    Beyer, Thomas; Lassen, Martin L; Boellaard, Ronald; Delso, Gaspar; Yaqub, Maqsood; Sattler, Bernhard; Quick, Harald H

    2016-02-01

    We assess inter- and intra-subject variability of magnetic resonance (MR)-based attenuation maps (MRμMaps) of human subjects for state-of-the-art positron emission tomography (PET)/MR imaging systems. Four healthy male subjects underwent repeated MR imaging with a Siemens Biograph mMR, Philips Ingenuity TF and GE SIGNA PET/MR system using product-specific MR sequences and image processing algorithms for generating MRμMaps. Total lung volumes and mean attenuation values in nine thoracic reference regions were calculated. Linear regression was used for comparing lung volumes on MRμMaps. Intra- and inter-system variability was investigated using a mixed effects model. Intra-system variability was seen for the lung volume of some subjects, (p = 0.29). Mean attenuation values across subjects were significantly different (p < 0.001) due to different segmentations of the trachea. Differences in the attenuation values caused noticeable intra-individual and inter-system differences that translated into a subsequent bias of the corrected PET activity values, as verified by independent simulations. Significant differences of MRμMaps generated for the same subjects but different PET/MR systems resulted in differences in attenuation correction factors, particularly in the thorax. These differences currently limit the quantitative use of PET/MR in multi-center imaging studies.

  20. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial.

    PubMed

    Kalra, Pinky; Rao, Arathi; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-02-01

    Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis . Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words: Protaper, rotary, periapical extrusion.

  1. Physiological and subjective responses in the elderly when using floor heating and air conditioning systems.

    PubMed

    Hashiguchi, Nobuko; Tochihara, Yutaka; Ohnaka, Tadakatsu; Tsuchida, Chiaki; Otsuki, Tamio

    2004-11-01

    The purpose of this study was to investigate the effects of a floor heating and air conditioning system on thermal responses of the elderly. Eight elderly men and eight university students sat for 90 minutes in a chair under the following 3 conditions: air conditioning system (A), floor heating system (F) and no heating system (C). The air temperature of sitting head height for condition A was 25 degrees C, and the maximum difference in vertical air temperature was 4 degrees C. The air and floor temperature for condition F were 21 and 29 degrees C, respectively. The air temperature for condition C was 15 degrees C. There were no significant differences in rectal temperature and mean skin temperature between condition A and F. Systolic blood pressure of the elderly men in condition C significantly increased compared to those in condition A and F. No significant differences in systolic blood pressure between condition A and F were found. The percentage of subjects who felt comfortable under condition F was higher than that of those under condition A in both age groups, though the differences between condition F and A was not significant. Relationships between thermal comfort and peripheral (e.g., instep, calf, hand) skin temperature, and the relationship between thermal comfort and leg thermal sensation were significant for both age groups. However, the back and chest skin temperature and back thermal sensation for the elderly, in contrast to that for the young, was not significantly related to thermal comfort. These findings suggested that thermal responses and physiological strain using the floor heating system did not significantly differ from that using the air conditioning system, regardless of the subject age and despite the fact that the air temperature with the floor heating system was lower. An increase in BP for elderly was observed under the condition in which the air temperature was 15 degrees C, and it was suggested that it was necessary for the elderly people to heat the room somehow in winter. Moreover, it is particularly important for elderly people to avoid a decrease in peripheral skin temperature, and maintain awareness of the warmth of peripheral areas, such as the leg, in order to ensure thermal comfort.

  2. The enkephalinergic nervous system and its immunomodulation on the developing immune system during the ontogenesis of oyster Crassostrea gigas.

    PubMed

    Liu, Zhaoqun; Zhou, Zhi; Wang, Lingling; Song, Xiaorui; Chen, Hao; Wang, Weilin; Liu, Rui; Wang, Mengqiang; Wang, Hao; Song, Linsheng

    2015-08-01

    Enkephalinergic neuroendocrine-immune regulatory system is one of the most important neuroendocrine-immune systems in both vertebrates and invertebrates for its significant role in the immune regulation. In the present study, the early onset of enkephalinergic nervous system and its immunomodulation on the developing immune system during the ontogenesis of oyster Crassostrea gigas were investigated to illustrate the function of neural regulation on the innate immune system in oyster larvae. [Met(5)]-enkephalin (Met-ENK) was firstly observed on the marginal of the dorsal half of D-hinged larvae. Six immune-related molecules, including four PRRs (CgCTL-1, CgCTL-2, CgCTL-4, CgNatterin-3) and two immune effectors (CgTNF-1 and CgEcSOD) were detected in the early developmental stages of trochophore, D-hinged and umbo larvae of oyster. After incubated with [Met(5)]-enkephalin, the mRNA expression level of all the PRRs changed significantly (p < 0.05). In trochophore larvae, the expression level of CgNatterin-3 decreased dramatically (p < 0.05) at 6 h, and the expression level of CgCTL-4 was significantly down-regulated at 3 h and 6 h (p < 0.05), respectively. In D-hinged and umbo larvae, only CgCTL-1 was significantly down-regulated and the differences were significant at 3 h and 6 h (p < 0.05), while the expression level of CgCTL-2 and CgCTL-4 increased significantly at 3 h after treatment (p < 0.05). Moreover, the expression levels of immune effectors were up-regulated significantly at 3 h and 6 h in trochophore larvae (p < 0.05). The expression level of CgTNF-1 in both blank and experiment groups was up-regulated but there was no significant difference in D-hinged larvae stage. On the contrary, the expression level of CgEcSOD in D-hinged larvae decreased dramatically at 3 h and 6 h after [Met(5)]-enkephalin incubation (p < 0.05). In umbo larvae, the expression level of CgTNF-1 and CgEcSOD in the experiment group increased significantly at 6 h after [Met(5)]-enkephalin treatment (p < 0.05), while no significant difference was found in the blank group. In addition, the anti-bacterial activities of the total protein extract from trochophore, D-hinged and umbo larvae increased significantly (p < 0.05) at both 3 h and 6 h after [Met(5)]-enkephalin incubation compared to that in the blank group, and PO activities of both D-hinged and umbo larvae total protein extract increased significantly (p < 0.05) while no significant difference was observed in trochophore larvae. The PO activities of the total protein extract in all the experiment groups decreased after the treatment with [Met(5)]-enkephalin for 6 h, but no significant difference was observed when compared to the blank group. Furthermore, after incubation for 6 h, the concentration of both CgTNF-1 and CgIL17-5 increased dramatically compared to that in the blank group (p < 0.05). These results together indicated that the enkephalinergic nervous system of oyster was firstly appeared in D-hinged larvae, while the primitive immune defense system existed in the region of prototroch in trochophore larvae and developed maturely after D-hinged larvae. The developing immune system could be regulated by the neurotransmitter [Met(5)]-enkephalin released by the neuroendocrine system in oyster C. gigas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. The effect of acetazolamide on different ocular vascular beds.

    PubMed

    Haustein, Michael; Spoerl, Eberhard; Boehm, Andreas G

    2013-05-01

    To assess the effect of acetazolamide (AZ) on different ocular vascular beds. In a prospective study, 32 healthy volunteers (16 male, 16 female) with a mean age of 23.9 ± 3.3 years (20-39 years) were included. Before and after intravenous administration of 1,000 mg AZ (single dose), ocular microcirculation parameters were measured every 20 min for 2 h. Retinal vessel diameters (VD) were measured by the retina vessel analyzer, blood flow (BF) in the neuroretinal rim by the laser doppler flowmeter according to Riva, and the parapapillary retinal BF by the scanning laser Doppler flowmeter. Additionally, the Langham ocular blood flow system was used to determine the ocular pulse amplitude (OPA) and the pulsatile ocular blood flow (pOBF). The measurements were correlated with systemic blood pressure (BP), ocular perfusion pressure (OPP), capillary base excess parameters and serum AZ levels. Arterial and venous VD were significantly increased by about 4-5% each. Papillary BF increased significantly about 40%. Parapapillary retinal flow dropped significantly about 19% (120 min). OPA and pOBF showed no statistically significant changes. BP showed no significant changes, and OPP was significantly increased. There were no correlations with pH or systemic perfusion parameters. AZ leads to a dilatation of retinal VD, to an increase of BF in the optic nerve head, and to a decrease of parapapillary retinal BF. The different BF changes in different vascular beds might be due to different regulatory mechanisms, steal effects, or different distributions of the carbonic anhydrase.

  4. Housing system and laying hen strain impacts on egg microbiology.

    PubMed

    Jones, D R; Anderson, K E

    2013-08-01

    Alternative hen housing is becoming more commonplace in the egg market. However, a complete understanding of the implications for alternative housing systems on egg safety has not been achieved. The current study examines the impact of housing Hy-Line Brown, Hy-Line Silver Brown, and Barred Plymouth Rock hens in conventional cage, cage-free, and free range egg production systems on shell microbiology. Eggs were collected at 4 sampling periods. Egg shell emulsion pools were formed and enumerated for total aerobic organisms, Enterobacteriaceae, and yeast and mold counts. Hy-Line Brown and Hy-Line Silver Brown hens produced eggs with significantly (P < 0.05 and 0.001, respectively) different levels of aerobic organisms dependent on housing system. Eggs from conventional cages had significantly different (P < 0.05) levels of aerobic contamination in relation to hen strain with Hy-Line Silver Brown having the greatest (4.57 log cfu/mL). Hy-Line Brown and Barred Plymouth Rock hens produced eggs with significantly different (P < 0.01) levels of Enterobacteriaceae among housing systems with conventional caged eggs having the lowest level of contamination for the hen strains. There were no differences within each strain among housing systems for yeast and mold contamination. The study shows that hen strain has an effect on egg microbial levels for various housing systems, and egg safety should be considered when making hen strain selections for each housing system.

  5. Multivariate analysis of meat production traits in Murciano-Granadina goat kids.

    PubMed

    Zurita-Herrera, P; Delgado, J V; Argüello, A; Camacho, M E

    2011-07-01

    Growth, carcass quality, and meat quality data from Murciano-Granadina kids (n=61) raised under three different systems were collected. Canonical discriminatory analysis and cluster analysis of the entire meat production process and its stages were performed using the rearing systems as grouping criteria. All comparisons resulted in significant differences and indicated the existence of three products with different quality characteristics as a result of the three rearing systems. Differences among groups were greater when comparing carcass and meat qualities as compared with growth differences. The paired analyses of canonical correlations among groups of variables integrated in growth, carcass and meat quality, resulted in all being statistically significant, pointing out the canonical correlation coefficient between carcass quality and meat quality. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Infectious bursal disease: seroprevalence and associated risk factors in major poultry rearing areas of Ethiopia.

    PubMed

    Jenbreie, Shiferaw; Ayelet, Gelagay; Gelaye, Esayas; Kebede, Fekadu; Lynch, Stacey E; Negussie, Haileleul

    2013-01-01

    The study was conducted in eight districts of Ethiopia with the objectives of determining the seroprevalence and associated risk factors of infectious bursal disease (IBD). From the total of 2,597 chicken serum samples examined using ELISA, 83.1 % were found positive. The highest seroprevalence was found at Mekele (90.3 %) while the lowest was recorded at Gondar district (69.8 %). These differences among the study areas were statistically significant (p < 0.05). Highest seroprevalence was found in crossbreed of chicken (91.4 %) while the lowest was recorded in indigenous breed of chicken (81.4 %). This difference was statistically significant (p < 0.05) among the three breeds of chickens, but sex was not statistically significant (p > 0.05). The seroprevalence of the disease was found high in young (≤ 8 weeks) age group (86.6 %) while the lowest prevalence was recorded in adults (>8 weeks) (72 %). This is also statistically significant (p < 0.05) between young and adult age groups. The prevalence of IBD in different production system indicated that higher seroprevalence was recorded in intensive production system (85.9 %) while the lowest was recorded in extensive production system (81.6 %). This difference is also statistically significant (p < 0.05).

  7. Affective reactions differ between Chinese and American healthy young adults: a cross-cultural study using the international affective picture system.

    PubMed

    Huang, Jinwen; Xu, Dongrong; Peterson, Bradley S; Hu, Jianbo; Cao, Linfeng; Wei, Ning; Zhang, Yingran; Xu, Weijuan; Xu, Yi; Hu, Shaohua

    2015-03-27

    Several cross-cultural studies have suggested that emotions are influenced by the cultural background. Emotional reactions to International Affective Picture System (IAPS) images were compared between Chinese and American young adults. 120 Chinese undergraduates (53 females, 67 males; aged 18-25 years) were enrolled at Zhejiang University, China, and the valence and arousal components of their emotional responses to IAPS images were rated using the Self-Assessment Manikin (SAM) system. Then, valence and arousal scores were compared to those of 100 American undergraduates (50 females, 50 males) of the same age group, enrolled at Florida University and surveyed by Prof. PJ Lang in 2001. Valence scores assigned to 259/816 (31.74%) pictures differed significantly between Chinese and American female participants, while those assigned to 165/816 (20.22%) pictures differed significantly between Chinese and American males (P < 6 × 10(-5)). Of the 816 pictures, the arousal scores assigned to 101/816 (12.38%) pictures differed significantly between Chinese and American female participants; these scores significantly differed in 130/816 (15.93%) pictures between Chinese and American males (P < 6 × 10(-5)). Valence scores for pictures in the Erotic category differed significantly between Chinese and American females (P < 6 × 10(-5)). There were no significant differences in valence scores for the remaining eight categories studied between participants from the two countries, whether female or male. The IAPS norms require a modification for their appropriate application in Asian cultures.

  8. Histomorphometry and bone mechanical property evolution around different implant systems at early healing stages: an experimental study in dogs.

    PubMed

    Jimbo, Ryo; Anchieta, Rodolfo; Baldassarri, Marta; Granato, Rodrigo; Marin, Charles; Teixeira, Hellen S; Tovar, Nick; Vandeweghe, Stefan; Janal, Malvin N; Coelho, Paulo G

    2013-12-01

    Commercial implants differ at macro-, micro-, and nanolevels, which makes it difficult to distinguish their effect on osseointegration. The aim of this study was to evaluate the early integration of 5 commercially available implants (Astra OsseoSpeed, Straumann SLA, Intra-Lock Blossom Ossean, Nobel Active, and OsseoFix) by histomorphometry and nanoindentation. Implants were installed in the tibiae of 18 beagle dogs. Samples were retrieved at 1, 3, and 6 weeks (n = 6 for each time point) and were histologically and nanomechanically evaluated. The results presented that both time (P < 0.01) and implant system and time interaction (P < 0.02) significantly affected the bone-to-implant contact (BIC). At 1 week, the different groups presented statistically different outcomes. No significant changes in BIC were noted thereafter. There were no significant differences in rank elastic modulus (E) or in rank hardness (H) for time (E: P > 0.80; H: P > 0.75) or implant system (E: P > 0.90; H: P > 0.85). The effect of different implant designs on osseointegration was evident especially at early stages of bone healing.

  9. Color Analysis of Periimplant Soft Tissues Focusing on Implant System: A Case Series.

    PubMed

    Varoni, Elena M; Moltrasio, Giuseppe; Gargano, Marco; Ludwig, Nicola; Lodi, Giovanni; Scaringi, Riccardo

    2017-04-01

    To assess the impact of implant system on color harmonization of periimplant mucosa. In this case series, color of periimplant mucosa was compared with color of natural tooth gingiva. Seventeen intercanine implants were analyzed (11 bone level [BL], 6 tissue level [TL] implants). Colorimetric data, at 2, 4, and 6 mm from gingival margin, were collected through fiber optics reflectance spectroscopy, and color differences calculated as ΔE. Dentists, dental students, and lay people, in blind, performed an additional visual color analysis on clinical images. Independently from implant system, the color of periimplant mucosa was significantly different from gingiva (ΔE = 8.2 ± 0.7), resulting darker at L* comparison (P ≤ 0.05). TL periimplant mucosa showed higher ΔE than BL (9.0 ± 1.0 vs 6.6 ± 0.8, respectively; P ≤ 0.05). Observers correctly identified where the implant was placed in about half of the cases, with no significant difference between implant systems. Within the limitations of this study, the color of periimplant soft tissues appears different from gingiva, at spectroscopic analysis. Color discrepancy results higher in the presence of TL implants than in BL implants, although the difference may not be clinically significant.

  10. Displacement comparison of CAD-CAM titanium and zirconia abutments to implants with different conical connections.

    PubMed

    Yilmaz, Burak; Hashemzadeh, Shervin; Seidt, Jeremy D; Clelland, Nancy L

    2018-04-01

    To compare the displacements of CAD-CAM zirconia and titanium abutments into different internal connection systems after torquing. OsseoSpeed EV and OsseoSpeed TX implants (n=10) were placed in resin blocks. Zirconia and titanium abutments (n=5) were first hand tightened and then tightened to the recommended torque (20Ncm for TX and 25Ncm for EV). Displacements of abutments between screw tightening by hand and torque driver was measured using three-dimensional digital image correlation (3D DIC) technique. Displacements were measured in U (front/back), V (into/outward), W (right/left) directions and 3-dimensionally (3D). ANOVA with restricted maximum likelihood estimation method was used to analyze the data. Bonferroni-corrected t tests was used to determine the statistical differences (α=0.05). 3D displacement of zirconia and titanium abutments was significantly greater in OsseoSpeed EV implant (P<0.001). Displacement of zirconia and titanium abutments was not significantly different within implant systems, 3D (P≥0.386) and in each direction (P≥0.382). In U and V directions, zirconia and titanium abutments displaced significantly more towards negative in OsseoSpeed EV implant (P<0.019). Within the OsseoSpeed TX system, abutments displaced significantly more in V direction compared to the U and W (P≤0.005), and within the Osseospeed EV system, abutment displacements were significantly different amongst directions and displacements in V were the greatest (P<0.001). Abutments displaced more in the implant that required higher torque values to tighten the abutment. The amount of displacement in both systems was clinically small. Abutment material did not affect the magnitude of displacement. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. The dependency of expiratory airway collapse on pump system and flow rate in liquid ventilated rabbits.

    PubMed

    Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B

    2003-05-30

    To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.

  12. Comparison of university and private-practice orthodontic treatment outcomes with the American Board of Orthodontics objective grading system.

    PubMed

    Cook, Devon R; Harris, Edward F; Vaden, James L

    2005-06-01

    Treatment outcomes and duration of treatment for patients treated in university graduate orthodontic programs and private orthodontic practices were assessed and compared with the ABO objective grading system. The treatment records of 139 randomly selected adolescents who had received comprehensive orthodontic treatment were examined. Seventy-seven subjects had been treated in 3 postgraduate orthodontic clinics, and 62 had been treated in 3 private orthodontic practices. Pretreatment, all subjects had Class II Division 1 malocclusions and ANB angles equal to or greater than 4 degrees . All patients were treated with premolar extractions. Posttreatment dental casts were measured and scored with the ABO objective grading system. No significant differences were found between the groups in the alignment, buccolingual inclination, and overjet components. Patients treated in private practice had significantly lower scores for marginal ridge height and occlusal relationship. Patients treated in the university programs had significantly lower scores for occlusal contact and interproximal contact components. There was no significant difference in the overall score, thus no significant difference in the overall quality of orthodontic treatment outcome between patients treated in university programs and private practices. However, the university group had a significantly larger sample variance for the overall score. There was no significant difference in the duration of the treatment between patients treated in a university setting and in a private practice.

  13. Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path Techniques.

    PubMed

    de Carvalho, Guilherme Moreira; Sponchiado Junior, Emílio Carlos; Garrido, Angela Delfina Bittencourt; Lia, Raphael Carlos Comelli; Garcia, Lucas da Fonseca Roberti; Marques, André Augusto Franco

    2015-12-01

    The aim of this study was to evaluate the apical transportation, the centering ability, and the cleaning effectiveness of a reciprocating single-file system associated to different glide path techniques. The mesial root canals of 52 mandibular molars were randomly distributed into 4 groups (n = 13) according to the different glide path techniques used before biomechanical preparation with Reciproc System (RS): KF/RS (sizes 10 and 15 K-files), NGP/RS (no glide path, only reciprocating system), PF/RS (sizes 13, 16, and 19 PathFile instruments), and NP (no preparation). Cone-beam computed tomography analysis was performed before and after instrumentation for apical third images acquisition. Apical transportation and its direction were evaluated by using the formula D = (X1 - X2) - (Y1 - Y2), and the centering ability was analyzed by the formula CC = (X1 - X2/Y1 - Y2 or Y1 - Y2/X1 - X2). The samples were submitted to histologic processing and analyzed under a digital microscope for debris quantification. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test, P < .05). All groups had similar apical transportation values, with no significant difference among them (P > .05). Groups had a tendency toward transportation in the mesial direction. No technique had perfect centering ability (=1.0), with no significant difference among them. KF/RS had larger amount of debris, with statistically significant difference in comparison with NGP/RS (P > .05). The different glide path techniques promoted minimal apical transportation, and the reciprocating single-file system tested remained relatively centralized within the root canal. Also, the different techniques interfered in the cleaning effectiveness of the reciprocating system. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of Vasopressin for Septic Shock in Patients on Chronic Renin-Angiotensin-Aldosterone System Inhibitors.

    PubMed

    Erwin, Beth L; Denaburg, Michael A; Barker, Andrew B; McArdle, Philip J; Windham, Samuel T; Morgan, Charity J

    2017-12-01

    To compare the hemodynamic response in septic shock patients receiving vasopressin who were on chronic renin-angiotensin-aldosterone system inhibitor therapy with those who were not. Single-center, retrospective cohort study. Medical and surgical ICUs at a 1,100-bed academic medical center. Medical and surgical ICU patients with septic shock who received vasopressin infusion added to at least one concomitant vasopressor agent between January 2014 and December 2015, then divided into two cohorts: 1) patients who were on chronic renin-angiotensin-aldosterone system inhibitor therapy as outpatients and 2) patients who were not on chronic renin-angiotensin-aldosterone system inhibitor therapy as outpatients. None. Mean arterial pressure at 6 hours was 72.2 mm Hg in the renin-angiotensin-aldosterone system inhibitor group versus 69.7 mm Hg in the non-renin-angiotensin-aldosterone system inhibitor group (p = 0.298). There was no difference in mean arterial pressure at 1, 24, or 48 hours between groups. Total concomitant vasopressor requirements, based on norepinephrine equivalents excluding vasopressin, were significantly lower at 24 hours in the renin-angiotensin-aldosterone system inhibitor group versus the non-renin-angiotensin-aldosterone system inhibitor group (10.7 vs 18.1 µg/min, respectively; p = 0.007), but no significant differences were seen at the other time points assessed. There were no significant differences in ICU or hospital length of stay or mortality. There was no significant difference in the primary outcome of 6-hour mean arterial pressure in septic shock patients receiving vasopressin who were on chronic renin-angiotensin-aldosterone system inhibitor therapy versus those receiving vasopressin who were not on chronic renin-angiotensin-aldosterone system inhibitor therapy. Renin-angiotensin-aldosterone system inhibitor patients had lower total concomitant vasopressor requirements at 24 hours compared with non-renin-angiotensin-aldosterone system inhibitor patients.

  15. Comparison of Free-Beam- and Fiber-Type CO2 Laser Delivery Systems in Stapes Surgery.

    PubMed

    Chang, Mun Young; Choi, Hyun Seok; Lee, Sang-Youp; Koo, Ja-Won

    2017-07-01

    A free-beam-type CO 2 laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO 2 laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO 2 lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. The mean operating time was significantly ( p =0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly ( p =0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly ( p =0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. Operating times were significantly shorter using the fiber-type CO 2 laser, while hearing outcomes did not differ significantly between the two groups.

  16. Accuracy and time requirements of a bar-code inventory system for medical supplies.

    PubMed

    Hanson, L B; Weinswig, M H; De Muth, J E

    1988-02-01

    The effects of implementing a bar-code system for issuing medical supplies to nursing units at a university teaching hospital were evaluated. Data on the time required to issue medical supplies to three nursing units at a 480-bed, tertiary-care teaching hospital were collected (1) before the bar-code system was implemented (i.e., when the manual system was in use), (2) one month after implementation, and (3) four months after implementation. At the same times, the accuracy of the central supply perpetual inventory was monitored using 15 selected items. One-way analysis of variance tests were done to determine any significant differences between the bar-code and manual systems. Using the bar-code system took longer than using the manual system because of a significant difference in the time required for order entry into the computer. Multiple-use requirements of the central supply computer system made entering bar-code data a much slower process. There was, however, a significant improvement in the accuracy of the perpetual inventory. Using the bar-code system for issuing medical supplies to the nursing units takes longer than using the manual system. However, the accuracy of the perpetual inventory was significantly improved with the implementation of the bar-code system.

  17. Revision rates after knee replacement. Cumulative results from worldwide clinical studies versus joint registers.

    PubMed

    Pabinger, C; Berghold, A; Boehler, N; Labek, G

    2013-02-01

    To assess revision rates after knee arthroplasty by comparing the cumulative results from worldwide clinical studies and arthroplasty registers. We hypothesised that the revision rate of all clinical studies of a given implant and register data would not differ significantly. A systematic review of clinical studies in indexed peer-reviewed journals was performed followed by internal and external validation. Parameters for measurement of revision were applied (Revision for any reason, Revisions per 100 observed component years). Register data served as control group. Thirty-six knee arthroplasty systems were identified to meet the inclusion criteria: 21 total knee arthroplasty (TKA) systems, 14 unicondylar knee arthroplasty (UKA) systems, one patello-femoral implant system. For 13 systems (36%), no published study was available that contained revision data. For 17 implants (47%), publications were available dealing with radiographic, surgical or technical details, but power was too weak to compare revision rates at a significant level. Six implant systems (17%) had a significant number of revisions published and were finally analysed. In general, developers report better results than independent users. Studies from developers represent an overproportional share of all observed component years. Register data report overall 10-year revision rates of TKA of 6.2% (range: 4.9-7.8%), rates for UKA are 16.5% (range: 9.7-19.6%). Revision rates of all clinical studies of a given implant do not differ significantly from register data. However, significant differences were found between the revision rates published by developers and register data. Therefore the different data need to be interpreted in the context of the source of the information. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Shaping ability of single-file reciprocating and heat-treated multifile rotary systems: a micro-CT study.

    PubMed

    Marceliano-Alves, M F V; Sousa-Neto, M D; Fidel, S R; Steier, L; Robinson, J P; Pécora, J D; Versiani, M A

    2015-12-01

    To investigate changes in three-dimensional geometry, in various cross-sectional morphological parameters and in the centring ability of root canals prepared with different preparation systems using microcomputed tomographic imaging technology. Sixty-four mesial canals of mandibular molars were matched based on similar morphological dimensions using micro-CT evaluation and assigned to four experimental groups (n = 16), according to the canal preparation technique: Reciproc, WaveOne, Twisted File and HyFlex CM systems. Changes in several 2D (area, perimeter, form factor, roundness, minor and major diameter) and 3D [volume, surface area, structure model index (SMI)] morphological parameters, as well as canal transportation, were compared with preoperative values using Kruskal-Wallis and anovapost hoc Tukey's tests with the significance level set at 5%. Preparation significantly increased all tested parameters in the experimental groups. No significant differences were observed between groups regarding changes in volume, surface area, SMI, form factor and roundness of the root canal after preparation (P > 0.05). In the apical third, the Reciproc group had significantly greater changes in canal area, perimeter, major and minor diameters than the other groups (P < 0.05). Overall, the Twisted File and HyFlex CM systems were associated with significantly less transportation than the reciprocating instruments, Reciproc and WaveOne (P < 0.05). Shaping procedures led to the enlargement of the root canal space with no evidence of significant preparation errors. Changes in 3D parameters were not different between groups whilst, in the apical third, Reciproc was associated with significantly greater changes in several 2D parameters compared to the other groups. Twisted File and HyFlex CM systems were able to maintain the original canal anatomy with less canal transportation than Reciproc and WaveOne; however, these differences are unlikely to be of clinical significance. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns.

    PubMed

    Sulaiman, F; Chai, J; Jameson, L M; Wozniak, W T

    1997-01-01

    The in vitro marginal fit of three all-ceramic crown systems (In-Ceram, Procera, and IPS Empress) was compared. All crown systems were significantly different from each other at P = 0.05. In-Ceram exhibited the greatest marginal discrepancy (161 microns), followed by Procera (83 microns), and IPS Empress (63 microns). There were no significant differences among the various stages of the crown fabrication: core fabrication, porcelain veneering, and glazing. The facial and lingual margins exhibited significantly larger marginal discrepancies than the mesial and distal margins.

  20. Evaluation of 4 Different Irrigating Systems for Apical Extrusion of Sodium Hypochlorite.

    PubMed

    Yost, Ross A; Bergeron, Brian E; Kirkpatrick, Timothy C; Roberts, Mark D; Roberts, Howard W; Himel, Van T; Sabey, Kent A

    2015-09-01

    The aim of this study was to evaluate NaOCl apical extrusion by using negative apical pressure (EndoVac), sonic agitation (EndoActivator), side-vented needle (Max-i-Probe), and photon induced photoacoustic streaming (PIPS 10 mJ and PIPS 20 mJ) laser irrigation in an in vitro gel model. Extracted mandibular and maxillary central incisors (n = 18) were prepared to size 35/.04 and 55/.04, respectively. Teeth were mounted in transparent containers with clear acrylic and suspended in a color-changing pH-sensitive gel, creating a closed system. By using a crossover design, each tooth was sequentially irrigated by using 6% NaOCl with each device following manufacturers' recommendations. Each tooth served as its own control. Pre-irrigation and post-irrigation buccal and proximal view photographs served to measure the longest distance of extrusion and were analyzed with ImageJ software. Mean results were analyzed by using Kruskal-Wallis and Dunn post hoc test (P < .05). There were no significant differences between EndoVac, EndoActivator, and the passive extrusion groups. The EndoVac and EndoActivator groups produced significantly less extrusion than PIPS irrigation. Max-i-Probe extrusion results were more variable than those of EndoActivator but had no significant difference. Across all irrigation systems, there were no significant differences with respect to apical preparation size. Under the in vitro conditions of this study, no difference was found between the 10 mJ and 20 mJ PIPS laser groups. EndoVac demonstrated significantly less potential for apical extrusion than PIPS and Max-i-Probe, whereas apical preparation size did not significantly affect extrusion of irrigant. The potential for apical extrusion of endodontic irrigants should be a consideration when selecting a system for final irrigation. Published by Elsevier Inc.

  1. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

    PubMed Central

    Kalra, Pinky; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-01-01

    Background Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. Aim The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Design Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Statistical analysis Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Results Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Conclusions Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words:Protaper, rotary, periapical extrusion. PMID:28210445

  2. Exploring Gender Differences in SMS-Based Mobile Library Search System Adoption

    ERIC Educational Resources Information Center

    Goh, Tiong-Thye

    2011-01-01

    This paper investigates differences in how male and female students perceived a short message service (SMS) library catalog search service when adopting it. Based on a sample of 90 students, the results suggest that there are significant differences in perceived usefulness and intention to use but no significant differences in self-efficacy and…

  3. In vivo efficacy of three different endodontic irrigation systems for irrigant delivery to working length of mesial canals of mandibular molars.

    PubMed

    Munoz, Hugo Roberto; Camacho-Cuadra, Karla

    2012-04-01

    Many in vitro studies have debated over the ability of different irrigant delivery and/or agitation systems to reach the apical third of curved root canals; however, little is known about irrigant penetration in vivo. Therefore, the purpose of this study was to compare the efficacy of the conventional endodontic irrigation needle, passive ultrasonic irrigation (PUI), and a negative pressure system for irrigant delivery to working length (WL) of mesial canals of mandibular molars. Thirty mesial canals of 30 vital mandibular first or second molars were randomly assigned into 3 groups (n = 10): (1) Monoject syringe with 27-gauge needle; (2) PUI with IrriSafe tip; and (3) EndoVac system. All canals were treated following the same preparation protocol to size 35/0.04 by using 5.25% NaOCl as irrigant during preparation procedure. Before obturation, canals were irrigated with 1 mL of a radiopaque solution by using the assigned irrigation system, and a digital radiograph was taken by using a parallel technique. With the aid of image editing software the distance between WL and maximum irrigant penetration was measured. Mean distances for Monoject, PUI, and EndoVac groups were 1.51 mm, 0.21 mm, and 0.42 mm, respectively. Analysis of variance test showed statistically significant differences between groups (P < .001). Tukey honestly significant difference test showed statistically significant differences between the Monoject group and the other 2 groups (P < .001) but no significant differences between PUI and EndoVac groups (P = .06). PUI and EndoVac are more effective than the conventional endodontic needle in delivering irrigant to WL of root canals. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Comparison of the AJCC, MSTS, and Modified Spanier Systems for Clinical and Pathologic Staging of Osteosarcoma.

    PubMed

    Cates, Justin M M

    2017-03-01

    The prognostic performance of the 2 most commonly used staging systems for skeletal sarcoma (the American Joint Committee on Cancer [AJCC] and Musculoskeletal Tumor Society [MSTS] systems) have never been compared analytically. Another staging system originally proposed by Spanier has not yet been validated. Given the recent release of the 8th edition of the AJCC Cancer Staging Manual, this study was designed to directly compare these anatomic staging systems in a series of 153 high-grade, intramedullary osteosarcomas. Kaplan-Meier curves were plotted and pairwise comparisons between each stage category were performed. Predictive accuracy of each staging system for determining 5-year disease-free survival was evaluated by comparing areas under receiver-operating characteristic curves generated from logistic regression analysis. Multiple concordance indices were calculated using bootstrapping methods (200 replications). ρk and R were estimated as measures of the variation in survival outcomes explained by the regression models. The AJCC, MSTS, and a modified version of the Spanier staging systems showed similar discriminatory abilities and no significant differences in the levels of contrast between different tumor stages across staging systems. Addition of T-category information from each staging system contributed significant prognostic information compared with a Cox proportional hazard regression model consisting only of the presence or absence of metastatic disease as a measure of disease extent. Concordance indices and predictive accuracy for 5-year disease-free survival were not significantly different among the different staging systems either. Similar findings were observed after accounting for other important prognostic variables. Additional studies are necessary to determine performance parameters of each staging system for other types of skeletal sarcoma. Prognostic performance of osteosarcoma staging systems would also be improved by incorporating nonanatomic prognostic variables into staging algorithms.

  5. Evaluation of heart rhythm variability and arrhythmia in children with systemic and localized scleroderma.

    PubMed

    Wozniak, Jacek; Dabrowski, Rafal; Luczak, Dariusz; Kwiatkowska, Malgorzata; Musiej-Nowakowska, Elzbieta; Kowalik, Ilona; Szwed, Hanna

    2009-01-01

    To evaluate possible disturbances in autonomic regulation and cardiac arrhythmias in children with localized and systemic scleroderma. There were 40 children included in the study: 20 with systemic and 20 with localized scleroderma. The control group comprised 20 healthy children. In 24-hour Holter recording, the average rate of sinus rhythm was significantly higher in the groups with systemic and localized scleroderma than in the control group, but there was no significant difference between them. The variability of heart rhythm in both groups was significantly decreased. In the group with systemic scleroderma, single supraventricular ectopic beats were observed in 20% and runs were seen in 40% of patients. In the group with localized scleroderma, supraventricular single ectopic beats occurred in 35% of patients and runs in 45% of those studied. Ventricular arrhythmia occurred in 2 children with systemic scleroderma, but in 1 child, it was complex. The most frequent cardiac arrhythmias in both types of scleroderma in children were of supraventricular origin, whereas ventricular arrhythmias did not occur very often. There were no significant differences in autonomic disturbances manifesting as a higher heart rate and decreased heart rate variability between localized and systemic scleroderma.

  6. Suitability of DCPs with screw locking elements to allow sufficient interfragmentary motion to promote secondary bone healing of osteoporotic fractures.

    PubMed

    Cuadrado, A; Yánez, A; Carta, J A; Garcés, G

    2013-06-01

    This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1, used for comparison purposes, represents a system comprised of a Locking Compression Plate (LCP) and eight locking screws. Groups 2 and 3 represent a system comprised of a DCP plate with eight cortical screws and two SLEs placed on the screws furthest from (group 2) and nearest to (group 3) the fracture. Group 4 represents the system comprised of a DCP plate with SLEs placed on all eight cortical screws. Cyclic compression tests of up to 10,000 load cycles were performed in order to determine the parameters of interest, namely the stiffnesses and the interfragmentary motion of the various configurations under consideration. Tukey's multiple comparison test was used to analyse the existence or otherwise of significant differences between the means of the groups. At 10,000 cycles, interfragmentary motion at the far cortex for group 2 was 0.60±0.04 mm and for group 3 0.59±0.03 mm (there being no significant differences: p=0.995). The mean interfragmentary motion at the far cortex of the LCP construct was 70% less than that of the two groups with 2SLEs (there being significant differences: p=1.1×10(-8)). In the case of group 4 this figure was 45% less than in groups 2 and 3 (there being significant differences: p=5.6×10(-6)). At 10,000 cycles, interfragmentary motion at the near cortex for group 2 was 0.24±0.06 mm and for group 3 0.24±0.03 mm (there being no significant differences: p=1.000). The mean interfragmentary motion at the near cortex of the LCP construct was 70.8% less than that of the two groups with 2SLEs (there being significant differences: p=0.011). In the case of group 4 this figure was 66.7% less than in groups 2 and 3 (there being significant differences: p=0.016). The mean stiffness at 10,000 cycles was 960±110 N mm(-1) for group 2 and 969±53 N mm(-1) for group 3 (there being no significant differences: p=1.000). For group 1 (the LCP construct) the mean stiffness at 10,000 cycles was 3144±446 N mm(-1), 3.25 times higher than that of groups 2 and 3 (there being significant differences: p=0.00002), and 1.6 times higher than that of the DCP+8SLEs construct (1944±408 N mm(-1), there being significant differences: p=0.007). It is concluded that using the DCP+2SLEs construct sufficient interfragmentary motion is ensured to promote secondary bone healing. However, if too many SLEs are used the result may be, as with the LCP, an excessively rigid system for callus formation. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Assessment Using AutoCAD Software of the Preparation of Dentin Walls in Root Canals Produced by 4 Different Endodontic Instrument Systems

    PubMed Central

    Cabanillas, Cristina; Monterde, Manuel; Pallarés, Antonio; Aranda, Susana; Montes, Raquel

    2015-01-01

    Objectives. To compare the effectiveness of four instrument systems for preparing oval root canals: manual instrumentation (Step-Back technique), ProTaper Universal, ProTaper Next, and Wave One. Material and Methods. For the purpose of this assessment, 60 teeth extracted for orthodontic or periodontal reasons, specifically canines and premolars with full coronal and root anatomy, were used and 15 samples were assigned to each group. The section of the canals was compared before and after instrumenting and the section of untouched canal wall was measured using AutoCAD software. The data was analysed by means of Shapiro-Wilk, ANOVA, and Kruskal-Wallis tests. Results. In the apical third, 100% of the canals were prepared with all the systems. In the middle third, a p value of 0.5989 in the Kruskal-Wallis test was obtained, which indicates no significant difference between the groups. At the coronal third level, the results obtained revealed that Wave One had a significantly lower mean average than the rest (p < 0.05). Conclusions. There are no differences between the various root canal instrument systems in the apical and middle thirds. At the coronal third level, Wave One system showed performance significantly worse than the rest, among which there were no differences. PMID:26664361

  8. Assessment Using AutoCAD Software of the Preparation of Dentin Walls in Root Canals Produced by 4 Different Endodontic Instrument Systems.

    PubMed

    Cabanillas, Cristina; Monterde, Manuel; Pallarés, Antonio; Aranda, Susana; Montes, Raquel

    2015-01-01

    Objectives. To compare the effectiveness of four instrument systems for preparing oval root canals: manual instrumentation (Step-Back technique), ProTaper Universal, ProTaper Next, and Wave One. Material and Methods. For the purpose of this assessment, 60 teeth extracted for orthodontic or periodontal reasons, specifically canines and premolars with full coronal and root anatomy, were used and 15 samples were assigned to each group. The section of the canals was compared before and after instrumenting and the section of untouched canal wall was measured using AutoCAD software. The data was analysed by means of Shapiro-Wilk, ANOVA, and Kruskal-Wallis tests. Results. In the apical third, 100% of the canals were prepared with all the systems. In the middle third, a p value of 0.5989 in the Kruskal-Wallis test was obtained, which indicates no significant difference between the groups. At the coronal third level, the results obtained revealed that Wave One had a significantly lower mean average than the rest (p < 0.05). Conclusions. There are no differences between the various root canal instrument systems in the apical and middle thirds. At the coronal third level, Wave One system showed performance significantly worse than the rest, among which there were no differences.

  9. Carcass and meat quality in light lambs from different fat classes in the EU carcass classification system.

    PubMed

    Sañudo, C; Alfonso, M; Sánchez, A; Delfa, R; Teixeira, A

    2000-09-01

    Ninety commercial lamb carcasses were analysed according to the four different fat classes in the light lamb European classification system. Shoulder fat increased 3%, muscle decreased 2% and bone decreased 1% for each class increase. No significant differences were found among fat classes regarding pH, WHC, cooking losses, juiciness, myoglobin content, meat colour measured immediately after cutting (L*, a*, b*), odour intensity or flavour quality. Some differences were found in colour evolution through ageing. Shear force decreased and tenderness and flavour intensity increased with fat class but this effect was only significant in the leanest animals.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friese, Ryan; Khemka, Bhavesh; Maciejewski, Anthony A

    Rising costs of energy consumption and an ongoing effort for increases in computing performance are leading to a significant need for energy-efficient computing. Before systems such as supercomputers, servers, and datacenters can begin operating in an energy-efficient manner, the energy consumption and performance characteristics of the system must be analyzed. In this paper, we provide an analysis framework that will allow a system administrator to investigate the tradeoffs between system energy consumption and utility earned by a system (as a measure of system performance). We model these trade-offs as a bi-objective resource allocation problem. We use a popular multi-objective geneticmore » algorithm to construct Pareto fronts to illustrate how different resource allocations can cause a system to consume significantly different amounts of energy and earn different amounts of utility. We demonstrate our analysis framework using real data collected from online benchmarks, and further provide a method to create larger data sets that exhibit similar heterogeneity characteristics to real data sets. This analysis framework can provide system administrators with insight to make intelligent scheduling decisions based on the energy and utility needs of their systems.« less

  11. The effect of three culture methods on intensive culture system of pacific white shrimp ( Litopenaeus vannamei)

    NASA Astrophysics Data System (ADS)

    Ma, Zhen; Wan, Rong; Song, Xiefa; Gao, Lei

    2013-09-01

    Different culture methods may affect the intensive culture system of Pacific white shrimp ( Litopenaeus vannamei) regarding water quality and growth and economic performance. This study evaluated the potential effects of three culture methods through cultivation of juvenile shrimps under consistent tank management conditions for 84 d. The three methods involved shrimp cultivation in different tanks, i.e., outdoor tanks with cement bottom (mode-C), greenhouse tanks with cement bottom (mode-G) and outdoor tanks with mud-substrate (mode-M). Results showed that water temperature was significantly higher in mode-G than that in mode-C ( P < 0.05). In contrast to the other two treatments, mode-M had stable pH after 50 d cultivation of shrimps. In the mid-late period, the average concentrations of TAN, NO2-N, DIP and COD were significantly lower in mode-M and mode-G compared with those in mode-C ( P < 0.05). Despite lack of differences in the final shrimp weight among different treatments ( P > 0.05), mode-M had significantly higher shrimp yield, survival rate and feed conversion rate ( P < 0.05) than other modes. There were significant differences in revenue and net return among different treatments ( P < 0.05). These demonstrated that the treatments of mode-G and mode-M were conductive to the intensive culture system of L. vannamei.

  12. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    PubMed

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  13. A comparison of MRI and CT imaging clarity of titanium alloy and titanium alloy with cobalt-chromium-alloy pedicle screw and rod implants in the lumbar spine.

    PubMed

    Trammell, Terry R; Flint, Kathy; Ramsey, Curtis J

    2012-08-15

    Magnetic resonance imaging (MRI) and computed tomography (CT) imaging are important postoperative diagnostic and evaluation tools, particularly in patients who have undergone spinal fusions. Advancements in materials and imaging techniques have lessened artifact and improved overall imaging results. Systems that combine titanium alloy and cobalt-chromium components have been introduced to reduce implant profile while maintaining strength. The objective of this study was to determine if there were any differences in the clarity of imaging between two types of implant materials in a lumbar spine construct model. One of two lumbar spine stabilization implant systems, titanium alloy (titanium) or titanium alloy with cobalt-chromium alloy (titanium-cobalt), was placed to simulate a four-level fusion construct in two human cadaveric spine segments, followed by MRI and CT imaging. The implant systems were then removed from each cadaver and implanted in the other cadaver. Nine physician graders from three subspecialties scored the images using a 5-point scale, with higher imaging scores indicating greater clarity of the region of interest. Physician-rated scores were compared across systems and between physician groups. There were no significant differences in the overall mean total scores on the basis of construct material. Overall mean scores were 18.16 for titanium and 17.45 for titanium-cobalt (p = 0.275). Among images of the titanium-cobalt constructs, no significant differences in mean scores were found between specimens with use of MRI (p = 0.883) or with use of CT only (p = 0.274). Among images of the titanium system, a slightly significant difference was found between specimens with use of MRI (p = 0.044) but not with CT imaging (p = 0.837). Overall image clarity scores were not significantly different between titanium and titanium-cobalt implant systems in the lumbar spine. Observation of pertinent anatomy in the regions of interest was not degraded by the presence of either system.

  14. Comparative Evaluation of Recombinant Protein Production in Different Biofactories: The Green Perspective

    PubMed Central

    Capaldi, Stefano

    2014-01-01

    In recent years, the production of recombinant pharmaceutical proteins in heterologous systems has increased significantly. Most applications involve complex proteins and glycoproteins that are difficult to produce, thus promoting the development and improvement of a wide range of production platforms. No individual system is optimal for the production of all recombinant proteins, so the diversity of platforms based on plants offers a significant advantage. Here, we discuss the production of four recombinant pharmaceutical proteins using different platforms, highlighting from these examples the unique advantages of plant-based systems over traditional fermenter-based expression platforms. PMID:24745008

  15. A web-based appointment system to reduce waiting for outpatients: a retrospective study.

    PubMed

    Cao, Wenjun; Wan, Yi; Tu, Haibo; Shang, Fujun; Liu, Danhong; Tan, Zhijun; Sun, Caihong; Ye, Qing; Xu, Yongyong

    2011-11-22

    Long waiting times for registration to see a doctor is problematic in China, especially in tertiary hospitals. To address this issue, a web-based appointment system was developed for the Xijing hospital. The aim of this study was to investigate the efficacy of the web-based appointment system in the registration service for outpatients. Data from the web-based appointment system in Xijing hospital from January to December 2010 were collected using a stratified random sampling method, from which participants were randomly selected for a telephone interview asking for detailed information on using the system. Patients who registered through registration windows were randomly selected as a comparison group, and completed a questionnaire on-site. A total of 5641 patients using the online booking service were available for data analysis. Of them, 500 were randomly selected, and 369 (73.8%) completed a telephone interview. Of the 500 patients using the usual queuing method who were randomly selected for inclusion in the study, responses were obtained from 463, a response rate of 92.6%. Between the two registration methods, there were significant differences in age, degree of satisfaction, and total waiting time (P<0.001). However, gender, urban residence, and valid waiting time showed no significant differences (P>0.05). Being ignorant of online registration, not trusting the internet, and a lack of ability to use a computer were three main reasons given for not using the web-based appointment system. The overall proportion of non-attendance was 14.4% for those using the web-based appointment system, and the non-attendance rate was significantly different among different hospital departments, day of the week, and time of the day (P<0.001). Compared to the usual queuing method, the web-based appointment system could significantly increase patient's satisfaction with registration and reduce total waiting time effectively. However, further improvements are needed for broad use of the system.

  16. Apically extruded debris with three contemporary Ni-Ti instrumentation systems: an ex vivo comparative study.

    PubMed

    Logani, Ajay; Shah, Naseem

    2008-01-01

    To comparatively evaluate the amount of apically extruded debris when ProTaper hand, ProTaper rotary and ProFile systems were used for the instrumentation of root canals. Thirty minimally curved, mature, human mandibular premolars with single canals were randomly divided into three groups of ten teeth each. Each group was instrumented using one of the three instrumentation systems: ProTaper hand, ProTaper rotary and ProFile. Five milliliters of sterile water were used as an irrigant. Debris extruded was collected in preweighed polyethylene vials and the extruded irrigant was evaporated. The weight of the dry extruded debris was established by comparing the pre- and postinstrumentation weight of polyethylene vials for each group. The Kruskal-Wallis nonparametric test and Mann-Whitney U test were applied to determine if significant differences existed among the groups ( P< 0.05). All instruments tested produced a measurable amount of debris. No statistically significant difference was observed between ProTaper hand and ProFile system ( P > 0.05). Although ProTaper rotary extruded a relatively higher amount of debris, no statistically significant difference was observed between this type and the ProTaper hand instruments ( P > 0.05). The ProTaper rotary extruded significantly more amount of debris compared to the ProFile system ( P< 0.05). Within the limitations of this study, it can be concluded that all instruments tested produced apical extrusion of debris. The ProTaper rotary extruded a significantly higher amount of debris than the ProFile.

  17. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Double-arm-bar Suturing System (with video).

    PubMed

    Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu

    2014-02-01

    Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.

  18. Characterizing the phytoplankton soup: pump and plumbing effects on the particle assemblage in underway optical seawater systems.

    PubMed

    Cetinić, Ivona; Poulton, Nicole; Slade, Wayne H

    2016-09-05

    Many optical and biogeochemical data sets, crucial for algorithm development and satellite data validation, are collected using underway seawater systems over the course of research cruises. Phytoplankton and particle size distribution (PSD) in the ocean is a key measurement, required in oceanographic research and ocean optics. Using a data set collected in the North Atlantic, spanning different oceanic water types, we outline the differences observed in concurrent samples collected from two different flow-through systems: a permanently plumbed science seawater supply with an impeller pump, and an independent system with shorter, clean tubing runs and a diaphragm pump. We observed an average of 40% decrease in phytoplankton counts, and significant changes to the PSD in 10-45 µm range, when comparing impeller and diaphragm pump systems. Change in PSD seems to be more dependent on the type of the phytoplankton, than the size, with photosynthetic ciliates displaying the largest decreases in cell counts (78%). Comparison of chlorophyll concentrations across the two systems demonstrated lower sensitivity to sampling system type. Observed changes in several measured biogeochemical parameters (associated with phytoplankton size distribution) using the two sampling systems, should be used as a guide towards building best practices when it comes to the deployment of flow-through systems in the field for examining optics and biogeochemistry. Using optical models, we evaluated potential impact of the observed change in measured phytoplankton size spectra onto scattering measurements, resulting in significant differences between modeled optical properties across systems (~40%). Researchers should be aware of the methods used with previously collected data sets, and take into consideration the potentially significant and highly variable ecosystem-dependent biases in designing field studies in the future.

  19. [Immunogenetic characteristics of the population of the Transcarpathian region of the UkrSSR ABO system erythrocyte antigen findings].

    PubMed

    Levaniuk, V F

    1977-01-01

    The phenotypes with their respective alleles frequencies of the ABO system were studied in 33 230 individuals of 9 ethnic groups of the Transcarpathian Region population. Statistically significant differences in allele frequencies were found in Gypsies, Germans and Slovaks as compared to those in the main Ukrainian population. There are significant differences between Hungarians and Gypsies of the Transcarpathian Region and analogous populations beyond the region. Absence of a reliable difference between gene pools of the Slav groups of the population and of Hungarians may point to the local origin of the later.

  20. Poultry farm hygiene: microbiological quality assessment of drinking water used in layer chickens managed under the battery cage and deep litter systems at three poultry farms in southwestern Nigeria.

    PubMed

    Folorunso, O R; Kayode, Sule; Onibon, V O

    2014-01-01

    Water troughs from deep litter and caged chicken water troughs (drinkers) fixed to each of the different 3-tier cages containing layer chickens in Farms A, B and C were subjected to a 7-day study which involved the monitoring of poultry farm hygiene. Drinkers were washed before filling with water on Day 1. For Days 3, 5 and 7 water was served without prior washing. The occurrence and characterization of the bacteria isolates were investigated and data obtained were analyzed and compared. For the bacterial count on Day 1, for layer chickens on cage system, no significant differences (p > 0.05) among the farms and between the farms tier interactions. On Day 3, no significant difference (p > 0.05) among the parameters. On Day 5, there was significant difference (p<0.05) among the farms and on Day 7, there was high significant difference (p < 0.01) among the farms. On Days 5 and 7, there were no significant differences (p>0.05) among the tiers nor between the interactions of the farms and tiers. The bacterial count in water troughs of layer chickens in deep litter system, on Day 1, had no significant differences (p > 0.05) between the farms, water troughs and their interactions. On Day 3, no significant difference (p > 0.05) among the parameters. On Days 5 and 7, there were significant difference (p<0.05) and a high significant difference (p < 0.01) between the farms respectively. On Days 5 and 7, no significant differences between the water troughs and between the interaction of the farms and the water troughs. Farm A isolates contained Staphylococcus aureus, Proteus vulgaris, Streptococcus faecalis, Escherichia coli, Staphylococcus epidermis, Klebsiella sp., Salmonella sp., Bacillus subtilis, Lactobacillus salivarius and Corynebacterium sp. Farm B had Staphylococcus aureus, S. epidermis, Bacillus subtilis, Corynebacterium sp., Escherichia coli, Streptococcus faecalis and Klebsiella sp. while for Farm C, apart from the prevalent bacteria isolates obtained in Farms A and B, additional 2 bacterial isolates, Lactobacillus salivarius and Pseudomonas aeuriginosa were found. In conclusion, water troughs when cleaned on daily basis carry minimum bacterial load. Those left for 3, 5 and 7 days uncleaned had progressively high bacterial loads, suggesting that the flock of birds and the consumers of the eggs and meat from the chickens are at risk of bacterial infection unless strict farm hygiene is ensured through regular monitoring.

  1. Fat embolus in femur fractures: a comparison of two reaming systems.

    PubMed

    Volgas, David A; Burch, Tommy; Stannard, James P; Ellis, Truitt; Bilotta, Jessica; Alonso, Jorge E

    2010-11-01

    To measure the amount of fat presented to the right heart during reaming and nail placement using two different reamer systems. Prospective, randomized clinical trial. University-based Level I Trauma Center. 20 patients with femur fractures. Patients with femur fractures were treated with intramedullary nailing using either reamer-irrigator-aspirator or a conventional reamer. four-chamber trans-esophageal echocardiogram was used to quantify the amount of fat presented to the right atrium. There were 2 female and 18 male patients enrolled, 10 in each group. There was no significant difference (p = 0.10) between reaming systems on the opening reamer, which was expected since both trial limbs used the same opening reamer. However, during the first pass of the reamer, the RIA showed a nearly-significant decrease in the volume of fat in the right atrium (p = 0.06). During passage of the nail, there was a significant difference with Group B having less fat embolus than Group A (p = 0.01). The power of this study is 0.81. The mean ISS was not significantly different between the two groups, nor was the sex, age or race. There was one death from cardiac complications in a patient who showed no fat during any phase of the procedure. This patient had significant mitral and aortic regurgitation pre-operatively. There was one patient with clinical fat embolism syndrome and one patient with a nonunion. There is a statistically significant difference in the amount of fat presented to the lungs using a RIA versus conventional reamer. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopy.

    PubMed

    Launders, J H; McArdle, S; Workman, A; Cowen, A R

    1995-01-01

    The significance of varying the viewing conditions that may affect the perceived threshold contrast of X-ray television fluoroscopy systems has been investigated. Factors investigated include the ambient room lighting and the viewing distance. The purpose of this study is to find the optimum viewing protocol with which to measure the threshold detection index. This is a particular problem when trying to compare the image quality of television fluoroscopy systems in different input field sizes. The results show that the viewing distance makes a significant difference to the perceived threshold contrast, whereas the ambient light conditions make no significant difference. Experienced observers were found to be capable of finding the optimum viewing distance for detecting details of each size, in effect using a flexible viewing distance. This allows the results from different field sizes to be normalized to account for both the magnification and the entrance air kerma rate differences, which in turn allow for a direct comparison of performance in different field sizes.

  3. CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems.

    PubMed

    Harandi, Azade; Mohammadpour Maleki, Fatemeh; Moudi, Ehsan; Ehsani, Maryam; Khafri, Soraya

    2017-01-01

    The aim of this study was to compare the dentine removing efficacy of Gates-Glidden drills with hand files, ProTaper and OneShape single-instrument system using cone-beam computed tomography (CBCT). A total of 39 extracted bifurcated maxillary first premolars were divided into 3 groups ( n =13) and were prepared using either Gates-Glidden drills and hand instruments, ProTaper and OneShape systems. Pre- and post-instrumentation CBCT images were obtained. The dentin thickness of canals was measured at furcation, and 1 and 2 mm from the furcation area in buccal, palatal, mesial and distal walls. Data were analyzed using one-way ANOVA test. Tukey's post hoc tests were used for two-by-two comparisons. Gates-Glidden drills with hand files removed significantly more ( P <0.001) dentine than the engine-driven systems in all canal walls (buccal, palatal, mesial and distal). There were no significant differences between OneShape and ProTaper rotary systems ( P >0.05). The total cervical dentine removal during canal instrumentation was significantly less with engine-driven file systems compared to Gates-Glidden drills. There were no significant differences between residual dentine thicknesses left between the various canal walls.

  4. IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

    PubMed Central

    Carrasco, Thaise Graciele; Carrasco-Guerisoli, Laise Daniela; Fröner, Izabel Cristina

    2008-01-01

    This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)-laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66°C). The LED unit produced the lowest temperature increase (0.29±0.13°C); but there was no significant difference between LED unit and LED-laser system (0.35±0.15°C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64°C), and LED-laser system the lowest (0.33±0.12°C); however, there was no difference between LED-laser system and LED unit (0.44±0.11°C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health. PMID:19089234

  5. Comparison of petroleum generation kinetics by isothermal hydrous and nonisothermal open-system pyrolysis

    USGS Publications Warehouse

    Lewan, M.D.; Ruble, T.E.

    2002-01-01

    This study compares kinetic parameters determined by open-system pyrolysis and hydrous pyrolysis using aliquots of source rocks containing different kerogen types. Kinetic parameters derived from these two pyrolysis methods not only differ in the conditions employed and products generated, but also in the derivation of the kinetic parameters (i.e., isothermal linear regression and non-isothermal nonlinear regression). Results of this comparative study show that there is no correlation between kinetic parameters derived from hydrous pyrolysis and open-system pyrolysis. Hydrous-pyrolysis kinetic parameters determine narrow oil windows that occur over a wide range of temperatures and depths depending in part on the organic-sulfur content of the original kerogen. Conversely, open-system kinetic parameters determine broad oil windows that show no significant differences with kerogen types or their organic-sulfur contents. Comparisons of the kinetic parameters in a hypothetical thermal-burial history (2.5 ??C/my) show open-system kinetic parameters significantly underestimate the extent and timing of oil generation for Type-US kerogen and significantly overestimate the extent and timing of petroleum formation for Type-I kerogen compared to hydrous pyrolysis kinetic parameters. These hypothetical differences determined by the kinetic parameters are supported by natural thermal-burial histories for the Naokelekan source rock (Type-IIS kerogen) in the Zagros basin of Iraq and for the Green River Formation (Type-I kerogen) in the Uinta basin of Utah. Differences in extent and timing of oil generation determined by open-system pyrolysis and hydrous pyrolysis can be attributed to the former not adequately simulating natural oil generation conditions, products, and mechanisms.

  6. How is Family Centered Care Perceived by Healthcare Providers from Different Countries? An International Comparison Study.

    PubMed

    Feeg, Veronica D; Paraszczuk, Ann Marie; Çavuşoğlu, Hicran; Shields, Linda; Pars, Hatice; Al Mamun, Abdullah

    2016-01-01

    Family-centered care (FCC) is a healthcare delivery model in which planning care for a child incorporates the entire family. The purpose of this study was to describe and compare how healthcare providers from three countries with varied cultural and healthcare systems perceive the concept FCC by measuring attitudes, and to psychometrically identify a measure that would reflect "family-centeredness." The Working with Families questionnaire, translated when appropriate, was used to capture participants' perceptions of caring for hospitalized children and their parents from pediatric healthcare providers in the United States, Australia and Turkey (n=476). The results indicated significantly more positive attitudes reported for working with children than parents for all countries and individual score differences across countries: the U.S. and Turkey child scores were significantly higher than Australia, whereas the U.S. and Australia parent scores were both significantly higher than Turkey. Perceptions of working with families were different for nurses from the three countries that call for a clearer understanding about perceptions in relation to delivery systems. Further analyses revealed FCS scores to be significantly different between nurses and physicians and significantly correlated with age, number of children and education. The results of this study add to our understanding of influences on practice from different countries and healthcare systems. The FCS score may be useful to determine baseline beliefs and ascertain effectiveness of interventions designed to improve FCC implementation. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effects of rearview cameras and rear parking sensors on police-reported backing crashes.

    PubMed

    Cicchino, Jessica B

    2017-11-17

    The objective of this study was to examine the effectiveness of rearview cameras, rear parking sensors, and both systems combined in preventing police-reported backing crashes. Negative binomial regression was used to compare rates of police-reported backing crash involvements per insured vehicle year in 22 U.S. states during 2009-2014 between passenger vehicle models with backing technologies and the same vehicle models where the optional systems were not purchased, controlling for other factors affecting crash risk. Rearview cameras were examined from four automakers, rear parking sensors from 2 automakers, and both systems combined from a single automaker. Rearview cameras reduced backing crash involvement rates by 17%. Reductions were larger for drivers 70 and older (36%) than for drivers younger than 70 (16%); however, estimates for older and younger drivers did not differ significantly from one another. The Buick Lucerne's rear parking sensor system reduced backing crash involvement rates significantly by 34%, but the reduction for Mercedes-Benz vehicles fit with a sensor system was small and not statistically significant. When averaged between the 2 automakers, effects were significantly larger for drivers 70 and older (38% reduction) than for drivers younger than 70 (1% increase); effects were significant for older but not younger drivers. Backing crash involvement rates were 13% lower among Mercedes-Benz vehicles with a rearview camera and parking sensors than among vehicles without, but this finding was not significant. Rearview cameras are effective in preventing police-reported backing crashes. Effects of rear parking sensors are less straightforward; it is unclear whether the Buick Lucerne system's benefits are due to the older age of its drivers, characteristics of the vehicle or system, or a combination. Systems may be especially beneficial to older drivers who might have limitations that make backing challenging. Although effect estimates did not differ significantly between older and younger drivers for both system types, the magnitude of the differences was large and the pattern of results was consistent across 6 of the 7 systems examined. When rear visibility systems become required equipment on new passenger vehicles in 2018, rearview cameras can be expected to prevent 1 in 6 backing crashes reported to police that involve equipped vehicles.

  8. Birth order in small multihospital systems.

    PubMed

    Luke, R D; Ozcan, Y A; Begun, J W

    1990-06-01

    The strategic behaviors of small multihospital systems have received little attention in the literature despite the fact that small systems are the predominant scale among multihospital systems. This study examines one important aspect of small-system strategic behaviors: the birth-order or evolutionary patterns of hospital acquisition. The evolutionary patterns of acquisition are compared across three strategic model types studied elsewhere: local market, investment, and historical. Using data obtained from a variety of sources, local market model systems are found, in the sequence of acquisition, to be significantly different from the other two model types in terms of relative distances of acquisitions from the initiating or parent hospital, the sizes of acquisition hospitals, the complexity of those hospitals, and the likelihood that the acquisitions are located in rural areas. Differences between parents and acquisitions are also significant, as hypothesized, for the market model system types, although they are not generally significant for the other two model types. The findings suggest that the market model represents an important strategic form that may have important implications for the restructuring of hospital markets.

  9. [Interventional effects of different management programs on the outcomes of stable chronic obstructive pulmonary disease patients].

    PubMed

    Zhang, Rong-bao; Tan, Xing-yu; He, Quan-ying; Chen, Qing; Gai, Jun; Wei, Jing-an; Wang, Yan

    2012-11-27

    To evaluate the interventional effects of different management programs on the outcomes of stable chronic obstructive pulmonary disease (COPD) patients. Systemic education, follow-up and control groups were divided according to the frequency of follow-ups and the profile of participating in education. A total of 157 patients were enrolled into the COPD database from May 2002 to May 2010. They were interviewed face-to-face at our department. The investigation contained general conditions, the frequency of acute exacerbations (AE) the previous year, COPD Assessment Test (CAT), Modified British Medical Research Council Dyspnea Scale (mMRC) and spirometric classification. A combined assessment was conducted. The frequency of AE and rate of AE < once the previous year in systemic education group was 0.9 ± 1.1 and 71.2%, 1.0 ± 0.8 and 68.6% in follow-up group and 1.4 ± 1.1 and 44.4% in control group. And the frequency of AE in systemic education and follow-up groups was significantly less than that in control group (P < 0.05). Rate of AE < once in systemic education and follow-up groups was significantly higher than that in control group (P < 0.01). CAT and rate of CAT ≤ 20 in systemic education, follow-up and control groups were 10.0 ± 5.0 and 96.2%, 11.1 ± 6.0 and 88.2%, 15.3 ± 6.8 and 64.8% respectively. CAT in systemic education and follow-up groups was significantly lower than that in control group (P < 0.01). Rate of CAT ≤ 20 in systemic education and follow-up groups was significantly higher than that in control group (P < 0.01). mMRC in systemic education, follow-up and control groups was 1.5 ± 0.8, 1.6 ± 0.9 and 2.1 ± 1.0 respectively. mMRC in systemic education and follow-up groups was significantly lower than that in control group (P < 0.05). Combined assessment showed that no significant difference existed in Types A and B among three groups (P > 0.05). Type C in the systemic education group was significantly higher than that of the control (P < 0.05). Type D in the systemic education and follow-up groups was significantly lower than that of the control (P < 0.01). Long-term systemic education and follow-up management program can reduce the frequency of AE of COPD effectively and improve the health status of COPD patients.

  10. Assessment of Natural Ventilation System for a Typical Residential House in Poland

    NASA Astrophysics Data System (ADS)

    Antczak-Jarząbska, Romana; Krzaczek, Marek

    2016-09-01

    The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.

  11. Numerical simulation of volume-controlled mechanical ventilated respiratory system with 2 different lungs.

    PubMed

    Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas

    2017-09-01

    Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93

    PubMed Central

    Muhogora, Wilbroad; Padovani, Renato; Bonutti, Faustino; Msaki, Peter; Kazema, R.

    2011-01-01

    The performances of three clinical computed radiography (CR) systems, (Agfa CR 75 (with CRMD 4.0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates)) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers’ characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly. PMID:21897559

  13. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93.

    PubMed

    Muhogora, Wilbroad; Padovani, Renato; Bonutti, Faustino; Msaki, Peter; Kazema, R

    2011-07-01

    The performances of three clinical computed radiography (CR) systems, (Agfa CR 75 (with CRMD 4.0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates)) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly.

  14. Drug delivery systems and materials for wound healing applications.

    PubMed

    Saghazadeh, Saghi; Rinoldi, Chiara; Schot, Maik; Kashaf, Sara Saheb; Sharifi, Fatemeh; Jalilian, Elmira; Nuutila, Kristo; Giatsidis, Giorgio; Mostafalu, Pooria; Derakhshandeh, Hossein; Yue, Kan; Swieszkowski, Wojciech; Memic, Adnan; Tamayol, Ali; Khademhosseini, Ali

    2018-04-05

    Chronic, non-healing wounds place a significant burden on patients and healthcare systems, resulting in impaired mobility, limb amputation, or even death. Chronic wounds result from a disruption in the highly orchestrated cascade of events involved in wound closure. Significant advances in our understanding of the pathophysiology of chronic wounds have resulted in the development of drugs designed to target different aspects of the impaired processes. However, the hostility of the wound environment rich in degradative enzymes and its elevated pH, combined with differences in the time scales of different physiological processes involved in tissue regeneration require the use of effective drug delivery systems. In this review, we will first discuss the pathophysiology of chronic wounds and then the materials used for engineering drug delivery systems. Different passive and active drug delivery systems used in wound care will be reviewed. In addition, the architecture of the delivery platform and its ability to modulate drug delivery are discussed. Emerging technologies and the opportunities for engineering more effective wound care devices are also highlighted. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Comparative evaluation of the accuracy of linear measurements between cone beam computed tomography and 3D microtomography.

    PubMed

    Mangione, Francesca; Meleo, Deborah; Talocco, Marco; Pecci, Raffaella; Pacifici, Luciano; Bedini, Rossella

    2013-01-01

    The aim of this study was to evaluate the influence of artifacts on the accuracy of linear measurements estimated with a common cone beam computed tomography (CBCT) system used in dental clinical practice, by comparing it with microCT system as standard reference. Ten bovine bone cylindrical samples containing one implant each, able to provide both points of reference and image quality degradation, have been scanned by CBCT and microCT systems. Thanks to the software of the two systems, for each cylindrical sample, two diameters taken at different levels, by using implants different points as references, have been measured. Results have been analyzed by ANOVA and a significant statistically difference has been found. Due to the obtained results, in this work it is possible to say that the measurements made with the two different instruments are still not statistically comparable, although in some samples were obtained similar performances and therefore not statistically significant. With the improvement of the hardware and software of CBCT systems, in the near future the two instruments will be able to provide similar performances.

  16. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    PubMed

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  17. Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose.

    PubMed

    Schernthaner, Ruediger E; Haroun, Reham R; Nguyen, Sonny; Duran, Rafael; Sohn, Jae Ho; Sahu, Sonia; Chapiro, Julius; Zhao, Yan; Radaelli, Alessandro; van der Bom, Imramsjah M; Mauti, Maria; Hong, Kelvin; Geschwind, Jean-François H; Lin, MingDe

    2018-03-01

    To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm 2 vs. 1.62 Gy and 526.8 Gy*cm 2 , p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm 2 , p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm 2 , p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

  18. An In vitro Comparison and Evaluation of Sealing Ability of Newly Introduced C-point System, Cold Lateral Condensation, and Thermoplasticized Gutta-Percha Obturating Technique: A Dye Extraction Study.

    PubMed

    Sinhal, Tapati Manohar; Shah, Ruchi Rani Purvesh; Jais, Pratik Subhas; Shah, Nimisha Chinmay; Hadwani, Krupali Dhirubhai; Rothe, Tushar; Sinhal, Neha Nilesh

    2018-01-01

    The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Sixty extracted maxillary central incisors were decoronated below the cementoenamel junction. Working length was established, and biomechanical preparation was done using K3 rotary files with standard irrigation protocol. Teeth were divided into three groups according to the obturation protocol; Group I-Cold lateral condensation, Group II-Thermoplasticized gutta-percha, and Group III-C-Point obturating system. After obturation all samples were subjected to microleakage assessment using dye extraction method. Obtained scores will be statistical analyzed using ANOVA test and post hoc Tukey's test. One-way analysis of variance revealed that there is significant difference among the three groups with P value (0.000 < 0.05). Tukey's HSD post hoc tests for multiple comparisons test shows that the Group II and III perform significantly better than Group I. Group III performs better than Group II with no significant difference. All the obturating technique showed some degree of microleakage. Root canals filled with C-point system showed least microleakage followed by thermoplasticized obturating technique with no significant difference among them. C-point obturation system could be an alternative to the cold lateral condensation technique.

  19. Adapting an Agent-Based Model of Socio-Technical Systems to Analyze Security Failures

    DTIC Science & Technology

    2016-10-17

    total number of non-blackouts differed from the total number in the baseline data to a statistically significant extent with a p- valueɘ.0003...the total number of non-blackouts differed from the total number in the baseline data to a statistically significant extent with a p-valueɘ.0003...I. Nikolic, and Z. Lukszo, Eds., Agent-based modelling of socio-technical systems. Springer Science & Business Media, 2013, vol. 9. [12] A. P. Shaw

  20. The private healtcare systems in europe. What can we learn from Russia?

    PubMed

    Akulin, Igor M; Chesnokova, Ekaterina A; Genovese2, Umberto; Amato, Simona; Ragazzoni, Massimo Gabriele

    2014-01-01

    The European healthcare system is characterized by different kinds of funding: public, insurance-based, and mixed. In Italy, the prolonged economic crisis and the need for a cost reduction in the public administrations make necessary a cut in expenditure, which has a significant impact also on the funding of the healthcare system. The comparison of different European healthcare systems may offer useful insights for a better definition of the European and / or national healthcare provision strategies, which would be economically and financially sustainable but also capable to protect the population health. In this regard, it is worth to analyze the Russian healthcare system, which in the last years has undergone significant changes in its structure and in the way healthcare services are supplied. The peculiarity of the Russian healthcare system, which is quite different from the European standards for both professional requirements and theoretical knowledge, makes Russia an absolutely interesting partner for a future joint venture research. This paper describes the Russian national healthcare system highlights the differences in the demographic and socio-economic structures relatively to the Italian model. The paper supports a reflection on the sustainability of the health care systems and on the organizational forms that would guarantee the supply of better healthcare services in terms of quality, appropriateness and safety, compatibly with its economic sustainability.

  1. Efficiency of Different Endodontic Irrigation and Activation Systems in Removal of the Smear Layer: A Scanning Electron Microscopy Study.

    PubMed

    Karade, Priyatam; Chopade, Rutuja; Patil, Suvarna; Hoshing, Upendra; Rao, Madhukar; Rane, Neha; Chopade, Aditi; Kulkarni, Anish

    2017-01-01

    This in vitro study was designed to evaluate and compare different endodontic irrigation and activation systems for removal of the intracanal smear layer. Forty recently extracted, non-carious human intact single rooted premolars were selected and divided into five groups ( n =10) according to the root canal irrigation systems; syringe and needle irrigation (CTR), sonic irrigation, passive ultrasonic irrigation (PUI) and EndoVac irrigation system. All groups were prepared to #40 apical size with K-files. Each sample was subjected to final irrigation by using four different irrigation/activation systems. After splitting the samples, one half of each root was selected for examination under scanning electron microscope (SEM). The irrigation systems were compared using the Fisher's exact test with the level of significance set at 0.05. The four groups did not differ from each other in the coronal and mid-root parts of the canal. In the apical part of the canal none of the methods could completely remove all the smear layer but EndoVac system showed significantly better removal of smear layer and debris than the other methods. Within the limitations of the present study, the EndoVac system cleaned the apical part of the canal more efficiently than sonic, ultrasonic and syringe and needle irrigation.

  2. Comparison of in vitro systems of protein digestion using either mammal or fish proteolytic enzymes.

    PubMed

    Moyano, F J; Savoie, L

    2001-02-01

    Hydrolysis of three different proteins by either crude fish digestive extracts or purified mammal proteases was assayed using two different in vitro systems. The closed system was a modification of the pH-stat method including a previous acid digestion. The open system used a digestion cell containing a semi-permeable membrane which allowed continuous separation of the final products of hydrolysis with a molecular cut-off of 1000 Da. Assays in both systems resulted a similar arrangement of the tested proteins in relation to their ability to be hydrolyzed, with casein>fish meal> or =soybean meal. With the exception of casein, no significant differences were found between results produced by any of the enzyme sources using the closed system. In constrast, significantly higher hydrolysis of all proteins was produced by mammal enzymes under conditions operating in the open system. Differences in the rate of release of amino acids measured in this latter system were related both to the type of protein and the origin of the enzymes. When using purified mammal enzymes, release of lysine or phenylalanine from casein and soybean was high, but low from fishmeal. Isoleucine and valine present in fishmeal were preferentially hydrolyzed by commercial enzymes, but glycine and proline by fish enzymes.

  3. A comparative study of the accuracy between plastic and metal impression transfer copings for implant restorations.

    PubMed

    Fernandez, Monica A; Paez de Mendoza, Carmen Y; Platt, Jeffrey A; Levon, John A; Hovijitra, Suteera T; Nimmo, Arthur

    2013-07-01

    A precise transfer of the position and orientation of the antirotational mechanism of an implant to the working cast is particularly important to achieve optimal fit of the final restoration. This study evaluated and compared the accuracy of metal and plastic impression copings for use in a full-arch mandibular edentulous simulation with four implants. Metal and plastic impression transfer copings for two implant systems, Nobel Biocare™ Replace and Straumann SynOcta®, were assessed on a laboratory model to simulate clinical practice. The accuracy of producing stone casts using these plastic and metal impression transfer copings was measured against a standard prosthetic framework consisting of a cast gold bar. A total of 20 casts from the four combinations were obtained. The fit of the framework on the cast was tested by a noncontact surface profilometer, the Proscan 3D 2000 A, using the one-screw test. The effects of implant/system and impression/coping material on gap measurements were analyzed using repeated measures ANOVA. The findings of this in vitro study were as follows: plastic copings demonstrated significantly larger average gaps than metal for Straumann (p = 0.001). Plastic and metal copings were not significantly different for Nobel (p = 0.302). Nobel had significantly larger average gaps than Straumann for metal copings (p = 0.003). Nobel had marginally smaller average gaps than Straumann (p = 0.096) for plastic copings. The system-by-screw location interaction was significant as well (p < 0.001), indicating significant differences among the four screw locations, but the location differences were not the same for the two systems. A rank transformation of the data was necessary due to the nonnormal distribution of the gap measurements. No adjustments were made for multiple comparisons. The metal impression copings were more accurate than plastic copings when using the Straumann system, and there was no difference between metal and plastic copings for the Nobel Replace system. The system-by-screw location was not conclusive, showing no correlation within each system. © 2013 by the American College of Prosthodontists.

  4. Differences in physical activity prevalence and trends from 3 U.S. surveillance systems: NHIS, NHANES, and BRFSS.

    PubMed

    Carlson, Susan A; Densmore, Dianna; Fulton, Janet E; Yore, Michelle M; Kohl, Harold W

    2009-01-01

    Three U.S. surveillance systems-National Health Interview Survey (NHIS), National Health and Nutrition Examination Survey (NHANES), and Behavioral Risk Factor Surveillance System (BRFSS)--estimate physical activity prevalence. Survey differences were examined qualitatively. Prevalence estimates by sex, age, and race/ethnicity were assessed for comparable survey periods. Trends were examined from NHIS 1998 to 2007, NHANES 1999 to 2006, and BRFSS 2001 to 2007. Age-adjusted prevalence estimates appeared most similar for NHIS 2005 (physically active: 30.2%, inactive: 40.7%) and NHANES 2005 to 2006 (physically active: 33.5%, inactive: 32.4%). In BRFSS 2005, prevalence of being physically active was 48.3% and inactive was 13.9%. Across all systems, men were more likely to be active than women; non-Hispanic whites were most likely to be active; as age increased, overall prevalence of being active decreased. Prevalence of being active exhibited a significant increasing trend only in BRFSS 2001 to 2007 (P < .001), while prevalence of being inactive decreased significantly in NHANES 1999 to 2006 (P < .001) and BRFSS 2001 to 2007 (P < .001). Different ways of assessing physical activity in surveillance systems result in different prevalence estimates. Before comparing estimates from different systems, all aspects of data collection and data analysis should be examined to determine if comparisons are appropriate.

  5. Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.

    PubMed

    Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı

    2016-11-23

    To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.

  6. Should I Stay or Should I Go? A Comparison Study of Intention to Leave among Public Child Welfare Systems with High and Low Turnover Rates

    ERIC Educational Resources Information Center

    Strolin-Goltzman, Jessica

    2008-01-01

    This comparison study analyzes the commonalties, similarities, and differences on supervisory and organizational factors between a group of high turnover systems and a group of low turnover systems. Significant differences on organizational factors, but not on supervisory factors, emerged from the statistical analysis. Additionally, this study…

  7. Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

    PubMed

    Renne, Walter; Wolf, Bethany; Kessler, Raymond; McPherson, Karen; Mennito, Anthony S

    2015-01-01

    This study evaluated the marginal gap of crowns fabricated using two new chairside computer-aided design/computer-aided manufacturing systems on preparations completed by clinicians with varying levels of expertise to identify whether common preparation errors affect marginal fit. The null hypothesis is that there is no difference in the mean marginal gaps of restorations of varying qualities and no difference in the mean marginal gap size between restorations fabricated using the PlanScan (D4D, Richardson, TX, USA) and the CEREC Omnicam (Sirona, Bensheim, Germany). The fit of 80 lithium disilicate crowns fabricated with the E4D PlanScan or CEREC Omnicam systems on preparations of varying quality were examined for marginal fit by using the replica technique. These same preparations were then visually examined against common criteria for anterior all-ceramic restorations and placed in one of four categories: excellent, good, fair, and poor. Linear mixed modeling was used to evaluate associations between marginal gap, tooth preparation rating, and fabrication machine. The fit was not significantly different between both systems across all qualities of preparation. The average fit was 104 μm for poor-quality preparations, 87.6 μm for fair preparations, 67.2 μm for good preparations, and 36.6 μm for excellent preparations. The null hypothesis is rejected. It can be concluded that preparation quality has a significant impact on marginal gap regardless of which system is used. However, no significant difference was found when comparing the systems to each other. Within the limitations of this in vitro study, it can be concluded that crown preparation quality has a significant effect on marginal gap of the restoration when the clinician uses either CEREC Omnicam or E4D PlansScan. © 2015 Wiley Periodicals, Inc.

  8. Effect of Different Surface Treatments on Repair Micro-shear Bond Strength of Silica- and Zirconia-filled Composite Resins

    PubMed Central

    Joulaei, Mohammad; Bahari, Mahmoud; Ahmadi, Anahid; Savadi Oskoee, Siavash

    2012-01-01

    Background and aims Effect of surface treatments on repair bond strength of aged composite resins might be different due to their dissimilar fillers. The aim was to evaluate the effect of different surface treatments on repair micro-shear bond strength (µSBS) of silica- (Spectrum TPH) and zirconia-filled (Filtek Z250) composite resins. Materials and methods Twenty-seven composite resin blocks were made from each type of composite resin: Z250 and Spectrum TPH. After aging, blocks of each type were randomly divided into three groups according to surface treatments: alloy primer, silane, and only surface roughening. Subsequently, each group was further subdivided into 3 subgroups based on the adhesive system used: Single Bond, Clearfil SE Bond, and Margin Bond. Four composite resin columns were added on each block. After thermocycling, µSBStest were done at cross head speed of 0.5 mm/min. Data was analysed using multifactor ANOVA, one-way ANOVA and a post-hoc Bonferroni tests (α = 0.05). Results Analysis of data showed that the effect of composite resin type was not significant (p > 0.05), but the effects of the type of surface treatment (p = 0.01) and the type of adhesive system (p = 0.01) were significant on repair µSBS. In addition, the cumulative effect of the composite type-surface treatment and the composite type with the type of adhesive system were not statistically significant (p > 0.05). However, the cumulative effects of the adhesive system-surface treatment (p = 0.03) and the composite type-the adhesive system-surface treatments (p = 0.002) were significant. Conclusion Although repair µSBS values of both silica- and zirconia-filled composite resins were similar, use of different combinations of surface treatments and adhesive systems affected their repair µSBS differently. PMID:23277859

  9. Phenotypic heterogeneity in the endothelium of the human vortex vein system.

    PubMed

    Yu, Paula K; Tan, Priscilla E Z; Cringle, Stephen J; McAllister, Ian L; Yu, Dao-Yi

    2013-10-01

    The vortex vein system is the drainage pathway for the choroidal circulation and serves an important function in the effective drainage of the exceptionally high blood flow from the choroidal circulation. As there are only 4-6 vortex veins, a large volume of blood must be drained from many choroidal veins into each individual vortex vein. The vortex vein system must also cope with passing through tissues of different rigidity and significant pressure gradient as it transverses from the intrao-cular to the extra-ocular compartments. However, little is known about how the vortex vein system works under such complex situations in both physiological and pathological condition. Endothelial cells play a vital role in other vascular systems, but they have not been studied in detail in the vortex vein system. The purpose of this study is to characterise the intracellular structures and morphology in both the intra-and extra-ocular regions of the human vortex vein system. We hypothesise the presence of endothelial phenotypic heterogeneity through the vortex vein system. The inferior temporal vortex vein system from human donor eyes were obtained and studied histologically using confocal microscopy. The f-actin cytoskeleton and nuclei were labelled using Alexa Fluor conjugated Phalloidin and YO-PRO-1. Eight regions of the vortex vein system were examined with the venous endothelium studied in detail with quantitative data obtained for endothelial cell and nuclei size and shape. Significant endothelial phenotypic heterogeneity was found throughout the vortex vein system with the most obvious differences observed between the ampulla and its downstream regions. Variation in the distribution pattern of smooth muscle cells, in particular the absence of smooth muscle cells around the ampulla, was noted. Our results suggest the presence of significantly different haemodynamic forces in different regions of the vortex vein system and indicate that the vortex vein system may play important roles in regulation of the choroidal circulation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    PubMed

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient satisfaction compared with conventional maxillary dentures. © 2011 Wiley Periodicals, Inc.

  11. Effects of systemic and non-systemic stresses on the thermal characteristics of corn

    NASA Technical Reports Server (NTRS)

    Kumar, R.; Silva, L. F.; Baer, M. E.

    1978-01-01

    Experiments were conducted on corn plants using a calibrated spectroradiometer under field conditions in the indium antimonide channel (InSb, 2.8 to 5.6 mm) and the mercury cadmium telluride channel (HgCdTe, 7 to 14 mm). A ground cover experiment, an experiment on nonsystemic corn plants, and an experiment on systemic-stressed corn plants were included. The average spectral radiance temperature of corn plant populations was found (1) to be statistically significantly different for four healthy corn plant populations, (2) to increase with increased blight severity, and (3) to be statistically significantly different for varying rates of nitrogen applications.

  12. Addressing An Audience: A Study of Expert-Novice Differences in Writing. Technical Report No. 3.

    ERIC Educational Resources Information Center

    Atlas, Marshall A.

    To investigate differences in the writing processes of novice and expert writers, a test of writing skills was developed that required subjects to write a business letter in defense of a particular system of public transportation in response to a letter objecting to that system. In the first of three experiments, significant differences were found…

  13. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    PubMed

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p < 0.0001). After removing the duplicates, the difference between the number of unique usability problems identified by the checklist method (n = 100) and usual method (n = 44) was significant (p < 0.0001). Differences between the mean severity of the real usability problems (1.83) and those identified by only one of the methods (usual = 2.05, checklist = 1.74) were significant (p = 0.001). This study revealed the potential of the two HE methods for identifying usability problems of health information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. T-2 mycotoxin treatment of newborn rat pups does not significantly affect nervous system functions in adulthood.

    PubMed

    Varró, Petra; Béldi, Melinda; Kovács, Melinda; Világi, Ildikó

    2018-03-01

    T-2 toxin is primarily produced by Fusarium sp. abundant under temperate climatic conditions. Its main harmful effect is the inhibition of protein synthesis. Causing oxidative stress, it also promotes lipid peroxidation and changes plasma membrane phospholipid composition; this may lead to nervous system alterations. The aim of the present study was to examine whether a single dose of T-2 toxin administered at newborn age has any long-lasting effects on nervous system functions. Rat pups were treated on the first postnatal day with a single intraperitoneal dose of T-2 toxin (0.2 mg/bwkg). Body weight of treated pups was lower during the second and third week of life, compared to littermates; later, weight gain was recovered. At young adulthood, behavior was tested in the open field, and no difference was observed between treated and control rats. Field potential recordings from somatosensory cortex and hippocampus slices did not reveal any significant difference in neuronal network functions. In case of neocortical field EPSP, the shape was slightly different in treated pups. Long-term synaptic plasticity was also comparable in both groups. Seizure susceptibility of the slices was not different, either. In conclusion, T-2 toxin did not significantly affect basic nervous system functions at this dose.

  15. Analysis of Natural Buffer Systems and the Impact of Acid Rain

    ERIC Educational Resources Information Center

    Powers, David C.; Yoder, Claude H.; Higgs, Andrew T.; Obley, Matt L.; Hess, Kenneth R.; Leber, Phyllis A.

    2005-01-01

    The environmental significance of acid rain on water systems of different buffer capacities is discussed. The most prevalent natural buffer system is created by the equilibrium between carbonate ions and carbon dioxide.

  16. In vitro comparison in a manikin model: increasing apical enlargement with K3 and K3XF rotary instruments.

    PubMed

    Olivieri, Juan Gonzalo; Stöber, Eva; García Font, Marc; González, Jose Antonio; Bragado, Pablo; Roig, Miguel; Duran-Sindreu, Fernando

    2014-09-01

    The aim of the study was to compare the K3 and K3XF systems (SybronEndo, Glendora, CA) after 1 and 2 uses by evaluating apical transportation, working length loss, and working time in a manikin model. Mesial canals of 40 extracted first mandibular molars were instrumented. Radiographs taken after instrumentation with #25, #30, #35, and #40 files were superimposed on the preoperative image in both mesiodistal and buccolingual angulations. AutoCAD (Autodesk Inc, San Rafael, CA) was used to measure working length loss and apical transportation at 0, 0.5, and 1 mm from the working length (WL). The working time was measured. Group comparison was analyzed using post hoc Tukey honestly significant difference tests (P < .05). No significant differences were found in apical transportation, working length loss between K3 and K3XF systems, or between the number of uses. Significant differences were found when canal enlargement was performed to a #35-40 (P < .05). K3 instrumentation performed significantly faster (29.6 ± 15.4) than with the K3XF system (40.2 ± 17.7) (P < .05). No differences were observed in working time when comparing the number of uses. K3 and R-phase K3XF rotary systems shaped curved root canals safely with minimal apical transportation, even up to a 40/04 file. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Prognostic value of computed tomography classification systems for intra-articular calcaneus fractures.

    PubMed

    Swords, Michael P; Alton, Timothy B; Holt, Sarah; Sangeorzan, Bruce J; Shank, John R; Benirschke, Stephen K

    2014-10-01

    There are several published computed tomography (CT) classification systems for calcaneus fractures, each validated by a different standard. The goal of this study was to measure which system would best predict clinical outcomes as measured by a widely used and validated musculoskeletal health status questionnaire. Forty-nine patients with isolated intra-articular joint depression calcaneus fractures more than 2 years after treatment were identified. All had preoperative CT studies and were treated with open reduction and plate fixation using a lateral extensile approach. Four different blinded reviewers classified injuries according to the CT classification systems of Crosby and Fitzgibbons, Eastwood, and Sanders. Functional outcomes evaluated with a Musculoskeletal Functional Assessment (MFA). The mean follow-up was 4.3 years. The mean MFA score was 15.7 (SD = 11.6), which is not significantly different from published values for midfoot injuries, hindfoot injuries, or both, 1 year after injury (mean = 22.1, SD = 18.4). The classification systems of Crosby and Fitzgibbons, Eastwood, and Sanders, the number of fragments of the posterior facet, and payer status were not significantly associated with outcome as determined by the MFA. The Sanders classification trended toward significance. Anterior process comminution and surgeon's overall impression of severity were significantly associated with functional outcome. The amount of anterior process comminution was an important determinant of functional outcome with increasing anterior process comminution significantly associated with worsened functional outcome (P = .04). In addition, the surgeon's overall impression of severity of injury was predictive of functional outcome (P = .02), as determined by MFA. Level III, comparative series. © The Author(s) 2014.

  18. Skin condition and its relationship to systemic inflammation in chronic obstructive pulmonary disease.

    PubMed

    Majewski, Sebastian; Pietrzak, Anna; Tworek, Damian; Szewczyk, Karolina; Kumor-Kisielewska, Anna; Kurmanowska, Zofia; Górski, Paweł; Zalewska-Janowska, Anna; Piotrowski, Wojciech Jerzy

    2017-01-01

    The systemic (extrapulmonary) effects and comorbidities of chronic obstructive pulmonary disease (COPD) contribute substantially to its burden. The supposed link between COPD and its systemic effects on distal organs could be due to the low-grade systemic inflammation. The aim of this study was to investigate whether the systemic inflammation may influence the skin condition in COPD patients. Forty patients with confirmed diagnosis of COPD and a control group consisting of 30 healthy smokers and 20 healthy never-smokers were studied. Transepidermal water loss, stratum corneum hydration, skin sebum content, melanin index, erythema index, and skin temperature were measured with worldwide-acknowledged biophysical measuring methods at the volar forearm of all participants using a multifunctional skin physiology monitor. Biomarkers of systemic inflammation, including high-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), and tumor necrosis factor α (TNF-α), were measured in serum using commercially available enzyme-linked immunosorbent assays. There were significant differences between COPD patients and healthy never-smokers in skin temperature, melanin index, sebum content, and hydration level ( P <0.05), but not for transepidermal water loss and erythema index. No significant difference was noted between COPD patients and smokers in any of the biophysical properties of the skin measured. The mean levels of hsCRP and IL-6 in serum were significantly higher in COPD patients and healthy smokers in comparison with healthy never-smokers. There were significant correlations between skin temperature and serum hsCRP ( R =0.40; P =0.02) as well as skin temperature and serum IL-6 ( R =0.49; P =0.005) in smokers. Stratum corneum hydration correlated significantly with serum TNF-α ( R =0.37; P =0.01) in COPD patients. Differences noted in several skin biophysical properties and biomarkers of systemic inflammation between COPD patients, smokers, and healthy never-smokers may suggest a possible link between smoking-driven, low-grade systemic inflammation, and the overall skin condition.

  19. Hospitalization costs of severe bacterial pneumonia in children: comparative analysis considering different costing methods

    PubMed Central

    Nunes, Sheila Elke Araujo; Minamisava, Ruth; Vieira, Maria Aparecida da Silva; Itria, Alexander; Pessoa, Vicente Porfirio; de Andrade, Ana Lúcia Sampaio Sgambatti; Toscano, Cristiana Maria

    2017-01-01

    ABSTRACT Objective To determine and compare hospitalization costs of bacterial community-acquired pneumonia cases via different costing methods under the Brazilian Public Unified Health System perspective. Methods Cost-of-illness study based on primary data collected from a sample of 59 children aged between 28 days and 35 months and hospitalized due to bacterial pneumonia. Direct medical and non-medical costs were considered and three costing methods employed: micro-costing based on medical record review, micro-costing based on therapeutic guidelines and gross-costing based on the Brazilian Public Unified Health System reimbursement rates. Costs estimates obtained via different methods were compared using the Friedman test. Results Cost estimates of inpatient cases of severe pneumonia amounted to R$ 780,70/$Int. 858.7 (medical record review), R$ 641,90/$Int. 706.90 (therapeutic guidelines) and R$ 594,80/$Int. 654.28 (Brazilian Public Unified Health System reimbursement rates). Costs estimated via micro-costing (medical record review or therapeutic guidelines) did not differ significantly (p=0.405), while estimates based on reimbursement rates were significantly lower compared to estimates based on therapeutic guidelines (p<0.001) or record review (p=0.006). Conclusion Brazilian Public Unified Health System costs estimated via different costing methods differ significantly, with gross-costing yielding lower cost estimates. Given costs estimated by different micro-costing methods are similar and costing methods based on therapeutic guidelines are easier to apply and less expensive, this method may be a valuable alternative for estimation of hospitalization costs of bacterial community-acquired pneumonia in children. PMID:28767921

  20. Effect of nanotechnology in self-etch bonding systems on the shear bond strength of stainless steel orthodontic brackets

    PubMed Central

    Hammad, Shaza M.; El-Wassefy, Noha; Maher, Ahmed; Fawakerji, Shafik M.

    2017-01-01

    ABSTRACT Objective: To evaluate the effect of silica dioxide (SiO2) nanofillers in different bonding systems on shear bond strength (SBS) and mode of failure of orthodontic brackets at two experimental times. Methods: Ninety-six intact premolars were divided into four groups: A) Conventional acid-etch and primer Transbond XT; B) Transbond Plus self-etch primer; and two self-etch bonding systems reinforced with silica dioxide nanofiller at different concentrations: C) Futurabond DC at 1%; D) Optibond All-in-One at 7%. Each group was allocated into two subgroups (n = 12) according to experimental time (12 and 24 hours). SBS test was performed using a universal testing machine. ARI scores were determined under a stereomicroscope. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to determine the size and distribution of nanofillers. One-way ANOVA was used to compare SBS followed by the post-hoc Tukey test. The chi-square test was used to evaluate ARI scores. Results: Mean SBS of Futurabond DC and Optibond All-in-One were significantly lower than conventional system, and there were no significant differences between means SBS obtained with all self-etch bonding systems used in the study. Lower ARI scores were found for Futurabond DC and Optibond All-in-One. There was no significant difference of SBS and ARI obtained at either time points for all bonding systems. Relative homogeneous distribution of the fillers was observed with the bonding systems. Conclusion: Two nanofilled systems revealed the lowest bond strengths, but still clinically acceptable and less adhesive was left on enamel. It is advisable not to load the brackets immediately to the maximum. PMID:28444018

  1. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies.

    PubMed

    Bastos, Laura Alves; Sousa, Ana Beatriz Silva; Drubi-Filho, Brahim; Panzeri Pires-de-Souza, Fernanda de Carvalho; Garcia, Lucas da Fonseca Roberti

    2015-02-01

    The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Preetching/Silorane and Methacrylate groups. Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

  2. Evaluation of the learning environment of urology residency training using the postgraduate hospital educational environment measure inventory.

    PubMed

    Binsaleh, Saleh; Babaeer, Abdulrahman; Alkhayal, Abdullah; Madbouly, Khaled

    2015-01-01

    The educational environment plays a crucial role in the learning process. We aimed to evaluate the educational-environment perceptions of Saudi urology residents using the postgraduate hospital educational environment measure (PHEEM) inventory, and to investigate associations of their perception with stages of residency program, regions of Saudi Arabia, and main sectors of the health care system. We used PHEEM to measure the educational environment of Saudi urology residents. Respondents' perception was compared regarding different levels of residency training, regions of Saudi Arabia, and sectors of the health care system. Internal reliability of the inventory was assessed using Cronbach's alpha coefficient. Out of 72 registered residents, 38 (53%) completed the questionnaire. The residents did not perceive their environment positively (77.7±16.5). No significant differences in perception were found among residents of different program stages or Saudi regions. Residents from different health care sectors differed significantly regarding the total PHEEM score (P=0.024) and the teaching subscale (P=0.017). The inventory showed a high internal consistency with Cronbach's alpha of 0.892. Saudi urology residents perceived the educational environment as less than satisfactory. Perception of the educational environment did not change significantly among different stages of the program or different regions of Saudi Arabia. However, some sectors of the health care system are doing better than others.

  3. Clinical evaluation of long-term users of two contact lens care preservative systems.

    PubMed

    Young, Graeme; Keir, Nancy; Hunt, Chris; Woods, Craig A

    2009-03-01

    To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye. Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits. Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having "good" or "excellent" wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments. Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

  4. Apical extrusion of debris in flat-oval root canals after using different instrumentation systems.

    PubMed

    Kirchhoff, Alison Luís; Fariniuk, Luiz Fernando; Mello, Isabel

    2015-02-01

    The purpose of this study was to evaluate the amount of apically extruded debris in flat-oval root canal systems during cleaning and shaping with different instrumentation systems. Seventy-two mandibular incisors were randomly assigned to 4 groups (n = 18) according to the instrumentation system to be used: the ProTaper Next rotary system (PTN; Dentsply Tulsa Dental, Tulsa, OK), the WaveOne reciprocating system (WO, Dentsply Tulsa Dental), the Twisted File Adaptive (TFA; SybronEndo, Orange, CA) rotary/reciprocating system, and the Self-Adjusting File (SAF) system (ReDent-Nova, Ra'anana, Israel). Debris extruded during the instrumentation was collected and dried in preweighed Eppendorf tubes. Three consecutive weights were obtained for each tube, and the average was calculated. The data were analyzed using the t test and analysis of variance (Games-Howell test). The SAF produced significantly more debris compared with the other systems (P < .05). No significant difference was noted amongst the PTN, WO, and TFA (P > .05). Regardless of the instrumentation system used, apical extrusion of debris was exhibited at some level, regardless of the instrumentation system used. The SAF was associated with the highest amount of debris extrusion compared with PTN, WO, and TFA. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Composite bonding to stainless steel crowns using a new universal bonding and single-bottle systems.

    PubMed

    Hattan, Mohammad Ali; Pani, Sharat Chandra; Alomari, Mohammad

    2013-01-01

    Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80) stainless steel crowns (SSCs) were divided into four groups (20 each). Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group), Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany), and Group C and Group D using two different brands of single-bottle adhesive systems. Shear bond strengths were calculated and the types of failure also were recorded. Results. The shear strength of Group B was significantly greater than that of other groups. No significant differences were found between the shear bond strengths of Groups C and D. The control group had significantly lower shear bond strength (P < 0.05) to composite than the groups that utilized bonding agents. Conclusion. Composites bonding to stainless steel crowns using the new universal bonding agent (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany) show significantly greater shear bond strengths and fewer adhesive failures when compared to traditional single-bottle systems.

  6. [Comparison of clinical effects between anterior cervical Zero-incision fusion system and traditional nail plate system in the treatment of cervical spondylotic myelopathy].

    PubMed

    Chang, Bu-Qing; Feng, Hu; Yu, Chao-Jiang; Huang, Kai; Gao, Xiao; Tang, Hao; Jiang, Yun-Chang

    2017-05-25

    To compare the short-term efficacy of anterior cervical discectomy and fusion(ACDF) with traditional nail plate system and Zero-profile device in the treatment of cervical spondylotic myelopathy(CSM). The clinical data of 45 patients with CSM treated from July 2014 to August 2015 was retrospectively analyzed. There were 23 males and 22 females with an average age of 53.7 years old(range, 32 to 71 years old). The course of disease was 5 months to 2 years. All the patients were treated with ACDF with 24 cases by traditional nail plate system fixation(group A) and 21 cases by Zero-P system fixation(group B). Operation time and intraoperative bleeding were compared between two groups. Neurological function and cervical pain were evaluated by Japanese Orthopaedic Association scores (JOA) and visual analogue scale (VAS), respectively. Cervical curvature(Cobb angle) change and intervertebral fusion were evaluated by X-rays and CT. And associated complications were analyzed in two groups. All the patients were followed up for 12 to 16 months with an average of 14 months. Operation time of group A and B was(87.6±23.2) min and (62.7±17.3) min respectively, and the difference was significant between two groups; and intraoperative bleeding was (80.2±36.8) ml and (78.4±29.6) ml respectively, and the difference was not significant. At final follow-up, JOA and VAS of all patients were obvious improved, but there was no significant difference between two groups. Preoperative Cobb angle in group A and B was (8.7±4.3) ° and (8.6±4.2) ° respectively, and the difference was significant. The Cobb angle at final follow-up was (14.5±6.4) ° and (17.4±8.6) ° respectively, and the difference between two groups was significant. The incidence of dysphagia in group A and B were 29.17% and 9.52% respectively, and there was significant difference between two groups. All intervertebral spaces got fusion at final follow-up. No tracheo-asophageal injury and recurrent laryngeal nerve damage or other complications were found. No fusional migration, subsidence, loosening, breakage, etc. were found. The clinical comparison of Zero-P interbody fixation system and cervical plate internal fixation for the treatment of cervical spondylosis was quite fair, but Zero-P showed a better therapeutic effect with improvement of life quality.

  7. Shear bond strength of one-step self-etch adhesives: pH influence

    PubMed Central

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2015-01-01

    Background: The aim of this study was to compare the shear bond strength of four one-step self-etch adhesives with different pH values to enamel and dentin. Materials and Methods: In this in vitro study, 200 bovine permanent mandibular incisors were used. Four one-step self-etch adhesives with different pH values were tested both on enamel and on dentin: Adper™ Easy Bond Self-Etch Adhesive (pH = 0.8-1), Futurabond NR (pH=2), G-aenial Bond (pH = 1.5), Clearfil S3 Bond (pH = 2.7). After adhesive systems application, a nanohybrid composite resin was inserted into the bonded surface. The specimens were placed in a universal testing machine. The shear bond strength was performed at a cross-head speed of 1 mm/min until the sample rupture. The shear bond strength values (MPa) of the different groups were compared with analysis of variance after that Kolmogorov and Smirnov tests were applied to assess normality of distributions. P < 0.05 was considered as significant. Results: In enamel shear bond strength, the highest shear bond strength values were reported with Futurabond NR (P < 0.01); however, no significant differences were found with Clearfil S3 Bond. The others adhesive systems showed lower shear bond strength values with significant differences between them (P < 0.05). When comparing the dentin shear bond strength, the lowest shear bond strength values were reported with Clearfil S3 Bond (P < 0.05), while there were no significant differences among the other three products (P > 0.05). Conclusion: The pH values of adhesive systems did not influence significantly their shear bond strength to enamel or dentin. PMID:26005459

  8. Differences in net global warming potential and greenhouse gas intensity between major rice-based cropping systems in China.

    PubMed

    Xiong, Zhengqin; Liu, Yinglie; Wu, Zhen; Zhang, Xiaolin; Liu, Pingli; Huang, Taiqing

    2015-12-02

    Double rice (DR) and upland crop-single rice (UR) systems are the major rice-based cropping systems in China, yet differences in net global warming potential (NGWP) and greenhouse gas intensity (GHGI) between the two systems are poorly documented. Accordingly, a 3-year field experiment was conducted to simultaneously measure methane (CH4) and nitrous oxide (N2O) emissions and changes in soil organic carbon (SOC) in oil rape-rice-rice and wheat-rice (representing DR and UR, respectively) systems with straw incorporation (0, 3 and 6 t/ha) during the rice-growing seasons. Compared with the UR system, the annual CH4, N2O, grain yield and NGWP were significantly increased in the DR system, though little effect on SOC sequestration or GHGI was observed without straw incorporation. Straw incorporation increased CH4 emission and SOC sequestration but had no significant effect on N2O emission in both systems. Averaged over the three study years, straw incorporation had no significant effect on NGWP and GHGI in the UR system, whereas these parameters were greatly increased in the DR system, i.e., by 108% (3 t/ha) and 180% (6 t/ha) for NGWP and 103% (3 t/ha) and 168% (6 t/ha) for GHGI.

  9. Differences in net global warming potential and greenhouse gas intensity between major rice-based cropping systems in China

    PubMed Central

    Xiong, Zhengqin; Liu, Yinglie; Wu, Zhen; Zhang, Xiaolin; Liu, Pingli; Huang, Taiqing

    2015-01-01

    Double rice (DR) and upland crop-single rice (UR) systems are the major rice-based cropping systems in China, yet differences in net global warming potential (NGWP) and greenhouse gas intensity (GHGI) between the two systems are poorly documented. Accordingly, a 3-year field experiment was conducted to simultaneously measure methane (CH4) and nitrous oxide (N2O) emissions and changes in soil organic carbon (SOC) in oil rape-rice-rice and wheat-rice (representing DR and UR, respectively) systems with straw incorporation (0, 3 and 6 t/ha) during the rice-growing seasons. Compared with the UR system, the annual CH4, N2O, grain yield and NGWP were significantly increased in the DR system, though little effect on SOC sequestration or GHGI was observed without straw incorporation. Straw incorporation increased CH4 emission and SOC sequestration but had no significant effect on N2O emission in both systems. Averaged over the three study years, straw incorporation had no significant effect on NGWP and GHGI in the UR system, whereas these parameters were greatly increased in the DR system, i.e., by 108% (3 t/ha) and 180% (6 t/ha) for NGWP and 103% (3 t/ha) and 168% (6 t/ha) for GHGI. PMID:26626733

  10. Differences in net global warming potential and greenhouse gas intensity between major rice-based cropping systems in China

    NASA Astrophysics Data System (ADS)

    Xiong, Zhengqin; Liu, Yinglie; Wu, Zhen; Zhang, Xiaolin; Liu, Pingli; Huang, Taiqing

    2015-12-01

    Double rice (DR) and upland crop-single rice (UR) systems are the major rice-based cropping systems in China, yet differences in net global warming potential (NGWP) and greenhouse gas intensity (GHGI) between the two systems are poorly documented. Accordingly, a 3-year field experiment was conducted to simultaneously measure methane (CH4) and nitrous oxide (N2O) emissions and changes in soil organic carbon (SOC) in oil rape-rice-rice and wheat-rice (representing DR and UR, respectively) systems with straw incorporation (0, 3 and 6 t/ha) during the rice-growing seasons. Compared with the UR system, the annual CH4, N2O, grain yield and NGWP were significantly increased in the DR system, though little effect on SOC sequestration or GHGI was observed without straw incorporation. Straw incorporation increased CH4 emission and SOC sequestration but had no significant effect on N2O emission in both systems. Averaged over the three study years, straw incorporation had no significant effect on NGWP and GHGI in the UR system, whereas these parameters were greatly increased in the DR system, i.e., by 108% (3 t/ha) and 180% (6 t/ha) for NGWP and 103% (3 t/ha) and 168% (6 t/ha) for GHGI.

  11. Results from field tests of the one-dimensional Time-Encoded Imaging System.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marleau, Peter; Brennan, James S.; Brubaker, Erik

    2014-09-01

    A series of field experiments were undertaken to evaluate the performance of the one dimensional time encoded imaging system. The significant detection of a Cf252 fission radiation source was demonstrated at a stand-off of 100 meters. Extrapolations to different quantities of plutonium equivalent at different distances are made. Hardware modifications to the system for follow on work are suggested.

  12. Comparing Cultural Differences in Two Quality Measures in Chinese Kindergartens: The Early Childhood Environment Rating Scale-Revised and the Kindergarten Quality Rating System

    ERIC Educational Resources Information Center

    Hu, Bi Ying

    2015-01-01

    This study examined the degrees of congruence between two early childhood evaluation systems on various quality concepts: the Early Childhood Environment Rating Scale-Revised (ECERS-R) and Zhejiang's Kindergarten Quality Rating System (KQRS). Analysis of variance and post hoc least significant difference tests were employed to show the extent to…

  13. Sexual dimorphism in immune function changes during the annual cycle in house sparrows

    NASA Astrophysics Data System (ADS)

    Pap, Péter László; Czirják, Gábor Árpád; Vágási, Csongor István; Barta, Zoltán; Hasselquist, Dennis

    2010-10-01

    Difference between sexes in parasitism is a common phenomenon among birds, which may be related to differences between males and females in their investment into immune functions or as a consequence of differential exposure to parasites. Because life-history strategies change sex specifically during the annual cycle, immunological responses of the host aiming to reduce the impact of parasites may be sexually dimorphic. Despite the great complexity of the immune system, studies on immunoecology generally characterise the immune status through a few variables, often overlooking potentially important seasonal and gender effects. However, because of the differences in physiological and defence mechanisms among different arms of the immune system, we expect divergent responses of immune components to environmental seasonality. In male and female house sparrows ( Passer domesticus), we measured the major components of the immune system (innate, acquired, cellular and humoral) during four important life-history stages across the year: (1) mating, (2) breeding, (3) moulting and (4) during the winter capture and also following introduction to captivity in aviary. Different individuals were sampled from the same population during the four life cycle stages. We found that three out of eight immune variables showed a significant life cycle stage × sex interaction. The difference in immune response between the sexes was significant in five immune variables during the mating stage, when females had consistently stronger immune function than males, while variables varied generally non-significantly with sex during the remaining three life cycle stages. Our results show that the immune system is highly variable between life cycle stages and sexes, highlighting the potential fine tuning of the immune system to specific physiological states and environmental conditions.

  14. Kinematid Parameters of Corrective Postural Responses Differ between Upper and Lower Body Perturbations

    NASA Technical Reports Server (NTRS)

    Sayenko, G.

    2004-01-01

    Balance control is disrupted following prolonged microgravity exposure, and to better understand this, both upper and lower body perturbations have been used to study postural control in space flight crewmembers. However, differences between several postural response indicators observed using the two techniques suggest that different sensory systems may be involved in organizing responses to these different perturbation approaches. The present study sought to compare differences in parameters of corrective postural responses between upper body perturbations (pushes to the chest) and forward translations of the support surface. Nine subjects participated in this study. Forward translations were performed using a NeuroCom EquiTest(TM) CDP system, which was synchronized with a Northern Digital OptoTrak motion tracking system (3 subjects). Chest pushes were applied using a hand-held force transducer device and were performed using a stabilometric system (6 subjects). Analysis of EMG has shown that: i) the earliest response of the leg muscles was registered significantly later during forward translation of the support surface than during chest pushes, and ii) there was a tendency for the different order of leg muscles activation during the translation tests. Analysis of the kinematic data showed a significant difference in the subject's body segments inclinations during corrective postural responses to upper and lower body perturbations. It appears that upper body perturbations likely engage the vestibular system more rapidly, while lower body perturbations likely engage somatosensory systems more rapidly. These differences must be taken into account when choosing the type of perturbation for testing postural function.

  15. COMPARISON OF RECENTLY USED PHACOEMULSIFICATION SYSTEMS USING A HEALTH TECHNOLOGY ASSESSMENT METHOD.

    PubMed

    Huang, Jiannan; Wang, Qi; Zhao, Caimin; Ying, Xiaohua; Zou, Haidong

    2017-01-01

    To compare the recently used phacoemulsification systems using a health technology assessment (HTA) model. A self-administered questionnaire, which included questions to gauge on the opinions of the recently used phacoemulsification systems, was distributed to the chief cataract surgeons in the departments of ophthalmology of eighteen tertiary hospitals in Shanghai, China. A series of senile cataract patients undergoing phacoemulsification surgery were enrolled in the study. The surgical results and the average costs related to their surgeries were all recorded and compared for the recently used phacoemulsification systems. The four phacoemulsification systems currently used in Shanghai are the Infiniti Vision, Centurion Vision, WhiteStar Signature, and Stellaris Vision Enhancement systems. All of the doctors confirmed that the systems they used would help cataract patients recover vision. A total of 150 cataract patients who underwent phacoemulsification surgery were enrolled in the present study. A significant difference was found among the four groups in cumulative dissipated energy, with the lowest value found in the Centurion group. No serious complications were observed and a positive trend in visual acuity was found in all four groups after cataract surgery. The highest total cost of surgery was associated with procedures conducted using the Centurion Vision system, and significant differences between systems were mainly because of the cost of the consumables used in the different surgeries. This HTA comparison of four recently used phacoemulsification systems found that each of system offers a satisfactory vision recovery outcome, but differs in surgical efficacy and costs.

  16. Micro-computed tomography evaluation of the preparation of mesiobuccal root canals in maxillary first molars with Hyflex CM, Twisted Files, and K3 instruments.

    PubMed

    Zhao, Dan; Shen, Ya; Peng, Bin; Haapasalo, Markus

    2013-03-01

    The aim of this study was to describe the canal shaping properties of Hyflex CM, Twisted Files (TF), and K3 rotary nickel-titanium files by using micro-computed tomography in maxillary first molars. A total of 36 mesiobuccal root canals of maxillary first molars were prepared with Hyflex CM, TF, or K3 system. Micro-computed tomography was used to scan the specimens before and after instrumentation. The volume of untreated canal, volume of dentin removed after preparation, amount of uninstrumented area, and the transportation for the coronal, middle, and apical thirds of canals were measured. Instrumentation of canals increased their volume and surface area. TF group showed the greatest amount of volumetric dentin removal (P < .05), whereas no significant difference was found in Hyflex CM and K3 groups. There were no significant differences among instrument types concerning uninstrumented area. The TF system produced significantly less transportation than the K3 system in the apical third of canals. No significant difference was found between TF and Hyflex CM instruments relating to apical transportation. In vitro, Hyflex and TF instruments shaped curved root canals in maxillary first molar without significant shaping errors. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  17. CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems

    PubMed Central

    Harandi, Azade; Mohammadpour Maleki, Fatemeh; Moudi, Ehsan; Ehsani, Maryam; Khafri, Soraya

    2017-01-01

    Introduction: The aim of this study was to compare the dentine removing efficacy of Gates-Glidden drills with hand files, ProTaper and OneShape single-instrument system using cone-beam computed tomography (CBCT). Methods and Materials: A total of 39 extracted bifurcated maxillary first premolars were divided into 3 groups (n=13) and were prepared using either Gates-Glidden drills and hand instruments, ProTaper and OneShape systems. Pre- and post-instrumentation CBCT images were obtained. The dentin thickness of canals was measured at furcation, and 1 and 2 mm from the furcation area in buccal, palatal, mesial and distal walls. Data were analyzed using one-way ANOVA test. Tukey’s post hoc tests were used for two-by-two comparisons. Results: Gates-Glidden drills with hand files removed significantly more (P<0.001) dentine than the engine-driven systems in all canal walls (buccal, palatal, mesial and distal). There were no significant differences between OneShape and ProTaper rotary systems (P>0.05). Conclusion: The total cervical dentine removal during canal instrumentation was significantly less with engine-driven file systems compared to Gates-Glidden drills. There were no significant differences between residual dentine thicknesses left between the various canal walls. PMID:28179920

  18. What can paper-based clinical information systems tell us about the design of computerized clinical information systems (CIS) in the ICU?

    PubMed

    Miller, A; Pilcher, D; Mercaldo, N; Leong, T; Scheinkestel, C; Schildcrout, J

    2010-08-01

    Screen designs in computerized clinical information systems (CIS) have been modeled on their paper predecessors. However, limited understanding about how paper forms support clinical work means that we risk repeating old mistakes and creating new opportunities for error and inefficiency as illustrated by problems associated with computerized provider order entry systems. This study was designed to elucidate principles underlying a successful ICU paper-based CIS. The research was guided by two exploratory hypotheses: (1) paper-based artefacts (charts, notes, equipment, order forms) are used differently by nurses, doctors and other healthcare professionals in different (formal and informal) conversation contexts and (2) different artefacts support different decision processes that are distributed across role-based conversations. All conversations undertaken at the bedsides of five patients were recorded with any supporting artefacts for five days per patient. Data was coded according to conversational role-holders, clinical decision process, conversational context and artefacts. 2133 data points were analyzed using Poisson logistic regression analyses. Results show significant interactions between artefacts used during different professional conversations in different contexts (chi(2)((df=16))=55.8, p<0.0001). The interaction between artefacts used during different professional conversations for different clinical decision processes was not statistically significant although all two-way interactions were statistically significant. Paper-based CIS have evolved to support complex interdisciplinary decision processes. The translation of two design principles - support interdisciplinary perspectives and integrate decision processes - from paper to computerized CIS may minimize the risks associated with computerization. 2010 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  19. Randomized controlled trial comparing embryo culture in two incubator systems: G185 K-System versus EmbryoScope.

    PubMed

    Barberet, Julie; Chammas, Jérémy; Bruno, Céline; Valot, Elodie; Vuillemin, Clarisse; Jonval, Lysiane; Choux, Cécile; Sagot, Paul; Soudry, Agnès; Fauque, Patricia

    2018-02-01

    To study whether the closed culture system, as compared with a benchtop incubator with similar culture conditions, has a positive impact on intracytoplasmic sperm injection (ICSI) outcomes. Randomized controlled trial. University hospital. A total of 386 patients undergoing ICSI cycles with at least six mature oocytes were randomized. Of these patients, 195 were assigned to the group with culture in a time-lapse imaging (TLI) system (EmbryoScope) and 191 to the group with culture in the G185 K-System (G185). Rate of implantation (primary endpoint) and embryo morphology grade. No significant differences were found in the implantation rates. The proportion of high-grade embryos on day 2 was significantly higher in the TLI group compared with the G185 group (40.4% vs. 35.2%). The impact of the incubator on embryo morphology remained significant in multivariate analysis, which took into account the woman's age, the rank of attempt, and the smoking status (TLI vs. G185: odds ratio = 1.27; 95% confidence interval, [1.04-1.55]). No difference was found in the mean number of frozen embryos, even though the total proportion of frozen embryos was significantly higher in the TLI group than in the G185 group (29.5% vs. 24.8%). No difference in implantation rate was found between the two incubators for fresh cycles. It remains to be determined whether the observed differences in embryo morphology and the total number of embryos cryopreserved would translate into higher cumulative outcomes with subsequent frozen embryo transfers. NCT02722252. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  20. Involvement of serotonin system in bullimia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marazziti, D.; Macchi, E.; Rotondo, A.

    1988-01-01

    Platelet /sup 3/H-imipramine binding was investigated in 8 patients affected by bulimia according to DSM III criteria, and in 7 health volunteers. The Bmax /+ -/SD (fmol/mg protein) was 356 /+ -/ 53 in patients, and 1144 /+ -/ 134 in controls. The Kd /+ -/ SD (nM) was 1.35 /+ -/ 0.44 in patients, and 1.90 /+ -/ 0.72 in controls. There was a significant difference in Bmax values in the two groups, whereas no significant difference was observed in Kd values. This study suggests the possible involvement of the indoleamine system in bullimia.

  1. Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems.

    PubMed

    Alsabeeha, Nabeel H M; Payne, Alan G T; De Silva, Rohana K; Thomson, W Murray

    2011-03-01

    To determine surgical and prosthodontic outcomes of mandibular single-implant overdentures, opposing complete maxillary dentures, using a wide diameter implant and large ball attachment system compared with different regular diameter implants with standard attachment systems. Thirty-six edentulous participants (mean age 68 years, SD 9.2) were randomly assigned into three treatment groups (n=12). A single implant was placed in the mandibular midline of participants to support an overdenture using a 6-week loading protocol. The control group received Southern regular implants and standard ball attachments. One group received Southern 8-mm-wide implants and large ball attachments. Another group received Neoss regular implants and Locator attachments. Parametric and non-parametric tests of a statistical software package (SPSS) were used to determine between groups differences in marginal bone loss, implant stability, implant, and prosthodontic success (P<0.05). Implant success after 1 year was 75% for Southern regular implant (control) group; and 100% for the Southern wide and Neoss regular implant groups (P=0.038). Mean marginal bone loss at 1 year was 0.19 mm (SD 0.39) without significant differences observed. Implant stability quotient (ISQ) at baseline was significantly lower for the Southern regular (control) group than the other two groups (P=0.001; P=0.009). At 1 year, no significant difference in implant stability was observed (mean ISQ 74.6, SD 6.1). The change in implant stability from baseline to 1 year was significant for the control group (P=0.025). Prosthodontic success was comparable between the groups but the maintenance (41 events overall, mean 1.2) was greater for the Locator and the standard ball attachments. Mandibular single-implant overdentures are a successful treatment option for older edentulous adults with early loading protocol using implants of different diameters and with different attachment systems. © 2010 John Wiley & Sons A/S.

  2. Biologic and Conventional Systemic Therapies Show Similar Safety and Efficacy in Elderly and Adult Patients With Moderate to Severe Psoriasis.

    PubMed

    Garber, Caren; Plotnikova, Natalia; Au, Shiu-chung; Sorensen, Eric P; Gottlieb, Alice

    2015-08-01

    Despite the aging population, few studies have documented the treatment of geriatric psoriasis. The purpose of this study is to compare the efficacy, safety, and prescribing patterns of biologics and conventional systemic medications in elderly versus adult psoriasis. All patient visits coded for psoriasis or psoriatic arthritis (ICD-9 696.1 or 696.0) at the Tufts Medical Center General Dermatology Clinic from January 1, 2008, to March 1, 2015 were included in this retrospective cohort study. The outcome measure used was the validated simple-measure for assessing psoriasis activity (S-MAPA), the product of the physician's global assessment and the body surface area. 194 patients who underwent 278 treatment courses were included in the study. 48 patients were included in the elderly cohort (≥ 65 years old) and 146 in the adult cohort (18-64 years old). There was no significant difference in S-MAPA improvement at 12 weeks between the two cohorts when treated with biologics (42.92% improvement in adults, 48.77% in elderly; P=0.498) or conventional systemics (43.96% and 51.82%, respectively; P=0.448). Within the elderly cohort, there was no significant difference in efficacy of biologics versus conventional systemics at any time point. Topical prescription rates were significantly higher in the elderly cohort ( P=0.004) while biologic prescription rates were significantly lower ( P=0.014) despite the same baseline S-MAPA in both age groups. For both biologics and conventional systemics, there was no statistically significant intergroup difference in the rate of adverse events ( P=0.322 for biologics; P=0.581 for conventional systemics) or infection ( P=0.753 for biologics; P=0.828 for conventional systemics). Within the elderly cohort, there was a higher rate of adverse events with conventional systemic treatment than with biologic treatment ( P=0.033). This study provides preliminary evidence to suggest that biologic and conventional systemic therapies are similarly safe and effective in the elderly and non-elderly cohorts. Within the elderly population, biologics may be a safer option than conventional systemic agents.

  3. The effect of two different Individually Ventilated Cage systems on anxiety-related behaviour and welfare in two strains of laboratory mouse.

    PubMed

    Burman, O; Buccarello, L; Redaelli, V; Cervo, L

    2014-01-30

    The environment in which a laboratory animal is housed can significantly influence its behaviour and welfare, acting as a potential confounding factor for those studies in which it is utilised. This study investigated the impact of two Individually Ventilated Cage (IVC) housing systems on anxiety-related behaviour and welfare indicators in two common strains of laboratory mice. Subjects were juvenile female C57BL/6J and BALB/c mice (N=128) housed in groups of four in two different IVC systems for 7weeks. System One had air delivery at the cage 'cover' level at 75 ACH (Air Changes/Hour) and System Two had air delivery at the 'animal' level at 50 ACH. Mice were assessed twice a week (e.g. bodyweight) or at the end of the study (e.g. anxiety tests). Our results showed significant differences in anxiety-related behaviour between strains and housing systems. Mice in System Two, regardless of strain, defecated more in the Elevated Plus Maze (EPM), spent less time in the open arms of the EPM, and less time in the central zone of the Open Field (OF). Strain differences in anxiety-like behaviour were seen in the increased defecation by BALB/c mice in the OF and EPM and less time spent in the open arms of the EPM compared to C57BL/6J mice. These results suggest that different IVC housing systems can influence mouse behaviour in different ways, with mice of both strains studied exhibiting more anxiety-related behaviour when housed in System Two (air entry at the 'animal' level at 50 ACH), which could impact upon experimental data. © 2013. Published by Elsevier Inc. All rights reserved.

  4. Consecutive Non-Significant Segments — Joinpoint Help System 4.4.0.0

    Cancer.gov

    Sometimes, the APC for one segment is significantly different from zero, but when an extra joinpoint in the segment is determined by the Joinpoint software, neither APCs for the two consecutive segments are significant. Why?

  5. Gait Biomechanics of Individuals with Transtibial Amputation: Effect of Suspension System

    PubMed Central

    Eshraghi, Arezoo; Abu Osman, Noor Azuan; Karimi, Mohammad; Gholizadeh, Hossein; Soodmand, Ehsan; Abas, Wan Abu Bakar Wan

    2014-01-01

    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial Registration Iranian Registry of Clinical Trials IRCT2013061813706N1. PMID:24865351

  6. Reassessing the NTCTCS Staging Systems for Differentiated Thyroid Cancer, Including Age at Diagnosis

    PubMed Central

    McLeod, Donald S.A.; Jonklaas, Jacqueline; Brierley, James D.; Ain, Kenneth B.; Cooper, David S.; Fein, Henry G.; Haugen, Bryan R.; Ladenson, Paul W.; Magner, James; Ross, Douglas S.; Skarulis, Monica C.; Steward, David L.; Xing, Mingzhao; Litofsky, Danielle R.; Maxon, Harry R.

    2015-01-01

    Background: Thyroid cancer is unique for having age as a staging variable. Recently, the commonly used age cut-point of 45 years has been questioned. Objective: This study assessed alternate staging systems on the outcome of overall survival, and compared these with current National Thyroid Cancer Treatment Cooperative Study (NTCTCS) staging systems for papillary and follicular thyroid cancer. Methods: A total of 4721 patients with differentiated thyroid cancer were assessed. Five potential alternate staging systems were generated at age cut-points in five-year increments from 35 to 70 years, and tested for model discrimination (Harrell's C-statistic) and calibration (R2). The best five models for papillary and follicular cancer were further tested with bootstrap resampling and significance testing for discrimination. Results: The best five alternate papillary cancer systems had age cut-points of 45–50 years, with the highest scoring model using 50 years. No significant difference in C-statistic was found between the best alternate and current NTCTCS systems (p = 0.200). The best five alternate follicular cancer systems had age cut-points of 50–55 years, with the highest scoring model using 50 years. All five best alternate staging systems performed better compared with the current system (p = 0.003–0.035). There was no significant difference in discrimination between the best alternate system (cut-point age 50 years) and the best system of cut-point age 45 years (p = 0.197). Conclusions: No alternate papillary cancer systems assessed were significantly better than the current system. New alternate staging systems for follicular cancer appear to be better than the current NTCTCS system, although they require external validation. PMID:26203804

  7. [The influences of geroprotectors on age-related changes of antioxidant system in rats liver under different light condition].

    PubMed

    Il'ina, T N; Vinogradova, I A; Iliukha, V A; Khizhkin, E A; Anisimov, V N; Khavinson, V Kh

    2008-01-01

    The influences of different light condition, melatonin and epithalon on liver antioxidant system in 6-, 12-, 18- and 24-month-old rats of both sexes were studied. The activities of antioxidant enzymes as well as concentration of tocopherol demonstrate high stability. The maximal number of significant changes in antioxidant system parameters was found under continuous light exposure. Light condition, sex and preparation modulated age-related changes of antioxidant system.

  8. Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

    PubMed

    da Frota, Matheus F; Espir, Camila G; Berbert, Fábio L C V; Marques, André A F; Sponchiado-Junior, Emílio C; Tanomaru-Filho, Mario; Garcia, Lucas F R; Bonetti-Filho, Idomeo

    2014-12-01

    As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

  9. Market Orientation in Universities: A Comparative Study of Two National Higher Education Systems

    ERIC Educational Resources Information Center

    Hemsley-Brown, Jane; Oplatka, Izhar

    2010-01-01

    Purpose: The paper's purpose is to test: whether there are significant differences between England and Israel, in terms of perceptions of market orientation (MO) in higher education (HE); which MO dimensions (student, competition, intra-functional) indicate more positive attitudes and whether the differences are significant; and the reliability of…

  10. Sulawesi cacao (Theobroma cacao, l.) performances under two different agricultural system in east coast of Central Sulawesi

    NASA Astrophysics Data System (ADS)

    Muslimin; Wijayanti, W.; Anshary, A.; Basri, Z.; Cruz, A. F.; Suwastika, I. N.; Shiina, T.

    2018-04-01

    Cacao (Theobroma cacao L.) is one major agricultural commodity from central Sulawesi, which is significantly affected by a range of pest and diseases including Cacao Pod Borer (CPB), Pod Rod Diseases (PRD), and Vascular Streak Dieback (VSD). Intensive and extensive approaches, including introduction of various new superior cultivars/clones, and development of eco-friendly agricultural system were implemented in order to overtake that problem. Here, we observed the performance of three different clones (namely: Sulawesi 1, MCC01, and Tadulako-1) in two different locations (Parigi and Poso-which located along east coast of central Sulawesi province), and under two different Agricultural management system (echo-friendly-intensive and Non-Intensive). All clones tested showed their well-adapted and suitable to local conditions. The performance of each clone can be improved by intensive management system. Based on all observed parameters (number of wet bean per pot, bean count, fat and shell percentage, and percentage of infection) it convincingly showed that intensive management system was working well in improving the quality and quantity of cacao beans production, and it fit to commercial requirements. The highest rate of infection was by Phytophthora, and no significant differences on the overall performances. Clones of Sulawesi-1 and MCC01 most likely was better than Tadulako-1.

  11. Illness intrusiveness explains race-related quality-of-life differences among women with systemic lupus erythematosus.

    PubMed

    Devins, G M; Edworthy, S M

    2000-01-01

    Our objective was to investigate whether quality of life in systemic lupus erythematosus (SLE) differs across ethnoracial groups and to identify factors that may explain race-related differences. Self-administered questionnaire data from 335 White, 40 Black, and 30 Asian women with SLE were obtained from a multi-center database. Measures assessed illness intrusiveness, psychological well-being, depressive symptoms, musculoskeletal pain, and learned helplessness. Extent of SLE disease activity was indexed by self-reported functional-system involvement. Educational attainment was indicated by number of years in school. Principal-components analysis reduced the four psychosocial measures to a single factor score. This represented psychosocial well-being In path analysis. Psychosocial well-being differed significantly across the three groups, with Whites reporting the highest, and Blacks the lowest, levels. Path analysis indicated that illness intrusiveness accounted for this race-related difference. Although disease activity was significantly associated with psychosocial well-being, it did not differ across ethnoracial groups. Illness intrusiveness and educational attainment emerged as independent mediators of the race-related difference in psychosocial well-being. We conclude that race-related quality-of-life differences exist among women with SLE and are mediated independently by illness intrusiveness and educational attainment.

  12. Metric Selection for Evaluation of Human Supervisory Control Systems

    DTIC Science & Technology

    2009-12-01

    finding a significant effect when there is none becomes more likely. The inflation of type I error due to multiple dependent variables can be handled...with multivariate analysis techniques, such as Multivariate Analysis of Variance (MANOVA) (Johnson & Wichern, 2002). However, it should be noted that...the few significant differences among many insignificant ones. The best way to avoid failure to identify significant differences is to design an

  13. Sex-related differences in striatal dopaminergic system after traumatic brain injury.

    PubMed

    Xu, Xiupeng; Cao, Shengwu; Chao, Honglu; Liu, Yinlong; Ji, Jing

    2016-06-01

    Several studies have demonstrated alterations in the dopamine (DA) system after traumatic brain injury (TBI). Additionally, the existence of significant sex-related differences in the dopaminergic system has long been recognized. Accordingly, the purpose of the present study was to investigate whether TBI would differentially alter, in female and male mice, the expression and the function of the striatal vesicular monoamine transporter-2 (VMAT-2), an important DA transporter. After controlled cortical impact (CCI) injury, female mice showed significantly lower striatal DA concentrations and K(+)-evoked DA output. By contrast, no significant sex-related differences were observed in the mRNA and protein levels of striatal dopamine transporter (DAT) and VMAT-2 and the methamphetamine (MA)-evoked DA output. These results demonstrated clear sex-related differences in striatal VMAT-2 function in response to TBI and suggested that female mice may be more sensitive to the TBI-induced inhibition of the VMAT-2 function, as indicated by the greater degree of deficits observed when the VMAT-2 DA-storage function was inhibited by TBI. Moreover, the TBI-induced suppression of locomotion was more pronounced than female mice. Such findings highlight the need for sex-specific considerations when examining differences among brain injury conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Effectiveness of a Case-Based System in Lesson Planning

    ERIC Educational Resources Information Center

    Saad, A.; Chung, P. W. H.; Dawson, C. W.

    2014-01-01

    Lesson planning imposes a significant burden on teachers as they need to prepare different lesson plans for different classes according to various constraints. SmartLP, a case-based lesson planning system, has been implemented as a means of assisting teachers in constructing quality lesson plans more quickly. SmartLP enables teachers to retrieve…

  15. Electroacoustic Performance of Direct-Input Hearing Aids with FM Amplification Systems.

    ERIC Educational Resources Information Center

    Thibodeau, Linda M.

    1990-01-01

    The electroacoustic performance of 18 direct-input and two inductive-coupling hearing aids was compared when operating with two different frequency modulation (FM) systems. The most significant differences occurred in full-on gain, equivalent-input noise, and frequency response, as opposed to high frequency average saturation sound pressure level…

  16. Comparison of Asian Aquaculture Products by Use of Statistically Supported Life Cycle Assessment.

    PubMed

    Henriksson, Patrik J G; Rico, Andreu; Zhang, Wenbo; Ahmad-Al-Nahid, Sk; Newton, Richard; Phan, Lam T; Zhang, Zongfeng; Jaithiang, Jintana; Dao, Hai M; Phu, Tran M; Little, David C; Murray, Francis J; Satapornvanit, Kriengkrai; Liu, Liping; Liu, Qigen; Haque, M Mahfujul; Kruijssen, Froukje; de Snoo, Geert R; Heijungs, Reinout; van Bodegom, Peter M; Guinée, Jeroen B

    2015-12-15

    We investigated aquaculture production of Asian tiger shrimp, whiteleg shrimp, giant river prawn, tilapia, and pangasius catfish in Bangladesh, China, Thailand, and Vietnam by using life cycle assessments (LCAs), with the purpose of evaluating the comparative eco-efficiency of producing different aquatic food products. Our starting hypothesis was that different production systems are associated with significantly different environmental impacts, as the production of these aquatic species differs in intensity and management practices. In order to test this hypothesis, we estimated each system's global warming, eutrophication, and freshwater ecotoxicity impacts. The contribution to these impacts and the overall dispersions relative to results were propagated by Monte Carlo simulations and dependent sampling. Paired testing showed significant (p < 0.05) differences between the median impacts of most production systems in the intraspecies comparisons, even after a Bonferroni correction. For the full distributions instead of only the median, only for Asian tiger shrimp did more than 95% of the propagated Monte Carlo results favor certain farming systems. The major environmental hot-spots driving the differences in environmental performance among systems were fishmeal from mixed fisheries for global warming, pond runoff and sediment discards for eutrophication, and agricultural pesticides, metals, benzalkonium chloride, and other chlorine-releasing compounds for freshwater ecotoxicity. The Asian aquaculture industry should therefore strive toward farming systems relying upon pelleted species-specific feeds, where the fishmeal inclusion is limited and sourced sustainably. Also, excessive nutrients should be recycled in integrated organic agriculture together with efficient aeration solutions powered by renewable energy sources.

  17. Maxillary arch width and buccal corridor changes with Damon and conventional brackets: A retrospective analysis.

    PubMed

    Shook, Corey; Kim, Sohyon Michelle; Burnheimer, John

    2016-07-01

    To evaluate the effect of Damon self-ligating and conventional bracket systems on buccal corridor widths and areas. A retrospective sample of consecutively treated patients using either conventional (CG, n  =  45) or Damon self-ligating (SL, n  =  39) brackets was analyzed to determine any differences in buccal corridor widths and areas both within and between groups. Pretreatment and posttreatment frontal photographs were transferred to Photoshop CC, standardized using intercanthal width, and linear and area measurements were performed with tools in Photoshop CC. Ratios were then calculated for statistical analysis. Relationships between arch widths and buccal corridors were also examined. There were no significant differences in the posttreatment intercanine or intermolar widths either within or between the CG and SL groups. There were no significant differences in any buccal corridor width or area measurement either within or between the CG and SL groups. There were strong correlations with the intercanine width and the corresponding buccal corridor smile width measurements. There was an inverse correlation with the buccal corridor area in relation to the canine and the total smile width. It is likely that posttreatment increases in arch width can be seen in patients treated with either a conventional bracket system or the Damon system. It is highly unlikely that there is any significant difference in buccal corridor width or area in patients treated with the Damon self-ligating system or a conventional bracket system.

  18. Adenosine transport systems on dissociated brain cells from mouse, guinea-pig, and rat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, M.E.; Geiger, J.D.

    1990-09-01

    The kinetics and sodium dependence of adenosine transport were determined using an inhibitor-stop method on dissociated cell body preparations obtained from mouse, guinea-pig and rat brain. Transport affinity (KT) values for the high affinity adenosine transport systems KT(H) were significantly different between these three species; mean +/- SEM values were 0.34 +/- 0.1 in mouse, 0.9 +/- 0.2 in rat, and 1.5 +/- 0.5 microM in guinea-pig. The KT values for the low affinity transport system KT(L) were not different between the three species. Brain cells from rat displayed a significantly greater maximal capacity to accumulate (3H)adenosine (Vmax) than didmore » mouse or guinea-pig for the high affinity system, or than did mouse for the low affinity system. When sodium chloride was replaced in the transport medium with choline chloride, the KT(H) values for guinea-pig and rat were both increased by approximately 100%; only in rat did the change reach statistical significance. The sodium-dependence of adenosine transport in mouse brain was clearly absent. The differences between KT(H) values in mouse and those in guinea-pig or rat were accentuated in the absence of sodium. The differences in kinetic values, ionic requirements, and pharmacological characteristics between adenosine transporters in CNS tissues of mouse, guinea-pig and rat may help account for some of the variability noted among species in terms of their physiological responses to adenosine.« less

  19. Racial differences in the mental health needs and service utilization of youth in the juvenile justice system.

    PubMed

    Rawal, Purva; Romansky, Jill; Jenuwine, Michael; Lyons, John S

    2004-01-01

    Mental health placement rates by the juvenile justice system differ by race. However, it is unknown whether mental health needs differ by race. This study attempted to investigate potential differences in mental health needs and service utilization among Caucasian, African American, and Hispanic juvenile justice involved youth. A stratified random sample of 473 youth petitioned, adjudicated, and incarcerated from 1995-1996 was examined using a standard chart review protocol and the Childhood Severity of Psychiatric Illness measure for mental health needs. Significant and unique mental health needs were demonstrated for all racial groups. African American youth demonstrated the greatest level of needs. Minority status indicated significantly lower rates of mental health service utilization. Minority youth in the juvenile justice system are most at risk for underserved mental health needs. Based on the current data, it can be inferred that the first contact with the state's child and adolescent serving system, which includes the juvenile justice and mental health sectors, appears to be through the juvenile justice sector for many minority youth with delinquency problems.

  20. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    PubMed

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth.

  1. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

    PubMed

    Juntavee, Niwut; Sirisathit, Issarawas

    2018-01-01

    This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p <0.05). Tukey's HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration ( p <0.05). Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.

  2. DSM-5 AND ICD-11 DEFINITIONS OF POSTTRAUMATIC STRESS DISORDER: INVESTIGATING “NARROW” AND “BROAD” APPROACHES

    PubMed Central

    Stein, Dan J.; McLaughlin, Katie A.; Koenen, Karestan C.; Atwoli, Lukoye; Friedman, Matthew J.; Hill, Eric D.; Maercker, Andreas; Petukhova, Maria; Shahly, Victoria; van Ommeren, Mark; Alonso, Jordi; Borges, Guilherme; de Girolamo, Giovanni; de Jonge, Peter; Demyttenaere, Koen; Florescu, Silvia; Karam, Elie G.; Kawakami, Norito; Matschinger, Herbert; Okoliyski, Michail; Posada-Villa, Jose; Scott, Kate M.; Viana, Maria Carmen; Kessler, Ronald C.

    2014-01-01

    Background The development of the Diagnostic and Statistical Manual of Mental Disorders 5th edition (DSM-5) and ICD-11 has led to reconsideration of diagnostic criteria for posttraumatic stress disorder (PTSD). The World Mental Health (WMH) Surveys allow investigation of the implications of the changing criteria compared to DSM-IV and ICD-10. Methods WMH Surveys in 13 countries asked respondents to enumerate all their lifetime traumatic events (TEs) and randomly selected one TE per respondent for PTSD assessment. DSMIV and ICD-10 PTSD were assessed for the 23,936 respondents who reported lifetime TEs in these surveys with the fully structured Composite International Diagnostic Interview (CIDI). DSM-5 and proposed ICD-11 criteria were approximated. Associations of the different criteria sets with indicators of clinical severity (distress-impairment, suicidality, comorbid fear-distress disorders, PTSD symptom duration) were examined to investigate the implications of using the different systems. Results A total of 5.6% of respondents met criteria for “broadly defined” PTSD (i.e., full criteria in at least one diagnostic system), with prevalence ranging from 3.0% with DSM-5 to 4.4% with ICD-10. Only one-third of broadly defined cases met criteria in all four systems and another one third in only one system (narrowly defined cases). Between-system differences in indicators of clinical severity suggest that ICD-10 criteria are least strict and DSM-IV criteria most strict. The more striking result, though, is that significantly elevated indicators of clinical significance were found even for narrowly defined cases for each of the four diagnostic systems. Conclusions These results argue for a broad definition of PTSD defined by any one of the different systems to capture all clinically significant cases of PTSD in future studies. PMID:24894802

  3. Influence of the quality of intraoperative fluoroscopic images on the spatial positioning accuracy of a CAOS system.

    PubMed

    Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo

    2018-06-01

    Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Magnetic Flux Density of Different Types of New Generation Magnetic Attachment Systems.

    PubMed

    Akin, Hakan

    2015-07-01

    The purpose of this study was to analyze the static magnetic flux density of different types of new generation laser-welded magnetic attachments in the single position and the attractive position and to determine the effect of different corrosive environments on magnetic flux density. Magnetic flux densities of four magnetic attachment systems (Hyper slim, Hicorex slim, Dyna, and Steco) were measured with a gaussmeter. Then magnetic attachment systems were immersed in two different media, namely 1% lactic acid solution (pH 2.3), and 0.9% NaCl solution (pH 7.3). Magnetic flux densities of the attachment systems were measured with a gaussmeter after immersion to compare with measurements before immersion (α = 0.05). The data were statistically evaluated with one-way ANOVA, paired-samples t-test, and post hoc Tukey-Kramer multiple comparisons tests (α = 0.05). The highest magnetic flux density was found in Dyna magnets for both single and attractive positions. In addition, after the magnets were in the corrosive environments for 2 weeks, they had a significant decrease in magnetic flux density (p < 0.05). No significant differences were found between corrosive environments (p > 0.05). The leakage flux of all the magnetic attachments did not exceed the WHO's guideline of 40 mT. The magnets exhibited a significant decrease in magnetic flux density after aging in corrosive environments including lactic acid and NaCl. © 2014 by the American College of Prosthodontists.

  5. Performance-Based Contracting Within a State Substance Abuse Treatment System: A Preliminary Exploration of Differences in Client Access and Client Outcomes

    PubMed Central

    Brucker, Debra L.; Stewart, Maureen

    2013-01-01

    To explore whether the implementation of performance-based contracting (PBC) within the State of Maine’s substance abuse treatment system resulted in improved performance, one descriptive and two empirical analyses were conducted. The first analysis examined utilization and payment structure. The second study was designed to examine whether timeliness of access to outpatient (OP) and intensive outpatient (IOP) substance abuse assessments and treatment, measures that only became available after the implementation of PBC, differed between PBC and non-PBC agencies in the year following implementation of PBC. Using treatment admission records from the state treatment data system (N=9,128), logistic regression models run using generalized equation estimation techniques found no significant difference between PBC agencies and other agencies on timeliness of access to assessments or treatment, for both OP and IOP services. The third analysis, conducted using discharge data from the years prior to and after the implementation of performance-based contracting (N=6,740) for those agencies that became a part of the performance-based contracting system, was designed to assess differences in level of participation, retention, and completion of treatment. Regression models suggest that performance on OP client engagement and retention measures was significantly poorer the year after the implementation of PBC, but that temporal rather than a PBC effects were more significant. No differences were found between years for IOP level of participation or completion of treatment measures. PMID:21249461

  6. Meta-analysis of Specific Music Therapy Measures and Their Implications for the Health Care System.

    PubMed

    Llovet, Aliza K

    The purpose of the activity reported in this article was to conduct an exhaustive search of the Journal of Music Therapy, filter the articles on the desired parameters, and organize data for analysis and interpretation. Specifically, the researcher studied whether (a) there was a significant difference in physiological measures, (b) there was a significant difference in quality of life, (c) there was a significant difference in satisfaction levels, (d) there was a significant difference in pain reduction, (e) there was a significant difference in procedural length, (f) there was a significant difference in length of stay, and (g) whether the overall effect size and 95% confidence level support the recommendation of music therapy in the health care setting. Twenty-four studies met criteria for inclusion in the systematic review. Results revealed an overall effect size of d = 0.61. However, results of the 95% confidence interval included 0, which suggests that there may not be a statistically significant difference in the health care setting on desired measures. Further results and implications are discussed within the article.

  7. Bacterial endotoxin adhesion to different types of orthodontic adhesives

    PubMed Central

    ROMUALDO, Priscilla Coutinho; GUERRA, Thaís Rodrigues; ROMANO, Fábio Lourenço; da SILVA, Raquel Assed Bezerra; BRANDÃO, Izaíra Tincani; SILVA, Célio Lopes; da SILVA, Lea Assed Bezerra; NELSON-FILHO, Paulo

    2017-01-01

    Abstract Bacterial endotoxin (LPS) adhesion to orthodontic brackets is a known contributing factor to inflammation of the adjacent gingival tissues. Objective The aim of this study was to assess whether LPS adheres to orthodontic adhesive systems, comparing two commercial brands. Material and Methods Forty specimens were fabricated from Transbond XT and Light Bond composite and bonding agent components (n=10/component), then contaminated by immersion in a bacterial endotoxin solution. Contaminated and non-contaminated acrylic resin samples were used as positive and negative control groups, respectively. LPS quantification was performed by the Limulus Amebocyte Lysate QCL-1000™ test. Data obtained were scored and subjected to the Chi-square test using a significance level of 5%. Results There was endotoxin adhesion to all materials (p<0.05). No statistically significant difference was found between composites/bonding agents and acrylic resin (p>0.05). There was no significant difference (p>0.05) among commercial brands. Affinity of endotoxin was significantly greater for the bonding agents (p=0.0025). Conclusions LPS adhered to both orthodontic adhesive systems. Regardless of the brand, the endotoxin had higher affinity for the bonding agents than for the composites. There is no previous study assessing the affinity of LPS for orthodontic adhesive systems. This study revealed that LPS adheres to orthodontic adhesive systems. Therefore, additional care is recommended to orthodontic applications of these materials. PMID:28877283

  8. Assessment of an automated capillary system for Plasmodium vivax microsatellite genotyping.

    PubMed

    Manrique, Paulo; Hoshi, Mari; Fasabi, Manuel; Nolasco, Oscar; Yori, Pablo; Calderón, Martiza; Gilman, Robert H; Kosek, Margaret N; Vinetz, Joseph M; Gamboa, Dionicia

    2015-08-21

    Several platforms have been used to generate the primary data for microsatellite analysis of malaria parasite genotypes. Each has relative advantages but share a limitation of being time- and cost-intensive. A commercially available automated capillary gel cartridge system was assessed in the microsatellite analysis of Plasmodium vivax diversity in the Peruvian Amazon. The reproducibility and accuracy of a commercially-available automated capillary system, QIAxcel, was assessed using a sequenced PCR product of 227 base pairs. This product was measured 42 times, then 27 P. vivax samples from Peruvian Amazon subjects were analyzed with this instrument using five informative microsatellites. Results from the QIAxcel system were compared with a Sanger-type sequencing machine, the ABI PRISM(®) 3100 Genetic Analyzer. Significant differences were seen between the sequenced amplicons and the results from the QIAxcel instrument. Different runs, plates and cartridges yielded significantly different results. Additionally, allele size decreased with each run by 0.045, or 1 bp, every three plates. QIAxcel and ABI PRISM systems differed in giving different values than those obtained by ABI PRISM, and too many (i.e. inaccurate) alleles per locus were also seen with the automated instrument. While P. vivax diversity could generally be estimated using an automated capillary gel cartridge system, the data demonstrate that this system is not sufficiently precise for reliably identifying parasite strains via microsatellite analysis. This conclusion reached after systematic analysis was due both to inadequate precision and poor reproducibility in measuring PCR product size.

  9. Comparison of Rai and Binet Classifications in Chronic Lymphocytic Leukemia.

    PubMed

    Zengin, N; Kars, A; Kansu, E; Özdemir, O; Barişta, İ; Güllü, İ; Güler, N; Özişik, Y; Dündar, S; Firat, D

    1997-01-01

    Staging systems are essential for understanding disease, in predicting the outcome, and therapeutic decision making in any tumor as well as chronic lymphocytic leukemia (CLL). In this study, we compared the clinical correlation of the Rai and Binet classification systems in 133 CLL patients. The distribution of 133 patients according to the Rai system was as follows, stage 0:17, I:13, II:45, III:30, IV:28, and in the Binet system stage A:35, B:40, C:58 patients. Median survival of patients according to the Rai staging system was >67.0, >91.0, 63.8, 20.9 and 9.8 months, and >91.0, 63.4, 16.0 months according to Binet, respectively. Although no difference was found between Rai stages 0, I, II (p > 0.05) in terms of median survival, the difference between these stages and stages III and IV was statistically significant (p < 0.05). In the Binet staging system statistically significant survival difference was found between all stages (p < 0.05). We concluded that although both systems are comparable in terms of staging and predicting the outcome of patients with CLL, the Rai staging system appears to have an advantage over the Binet system by defining a subset of patients with excellent prognosis (stage 0) which is included within stage A of the latter.

  10. Evaluation of the Accuracy and Related Factors of the Mechanical Torque-Limiting Device for Dental Implants

    PubMed Central

    Kazemi, Mahmood; Rohanian, Ahmad; Monzavi, Abbas; Nazari, Mohammad Sadegh

    2013-01-01

    Objective: Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style and two types of spring-style MTLDs at baseline, following fatigue conditions and sterilization processes were determined. Materials and Methods: Five unused MTLDs were selected from each of Straumann (ITI), Astra TECH and CWM systems. To measure the output of each MTLD, a digital torque gauge with a 3-jaw chuck was used to hold the driver. Force was applied to the MTLDs until either the friction styles released at a pre-calibrated torque value or the spring styles flexed to a pre-calibrated limit (target torque value). The peak torque value was recorded and the procedure was repeated 5 times for each MTLD. Then MTLDs were subjected to fatigue conditions at 500 and 1000 times and steam sterilization processes at 50 and 100 times and the peak torque value was recorded again at each stage. Results: Adjusted difference between measured torque values and target torque values differed significantly between stages for all 3 systems. Adjusted difference did not differ significantly between systems at all stages, but differed significantly between two different styles at baseline and 500 times fatigue stages. Conclusion: Straumann (ITI) devices differed minimally from target torque values at all stages. MTLDs with Spring-style were significantly more accurate than Friction-style device in achieving their target torque values at baseline and 500 times fatigue. PMID:23724209

  11. Effect of Casein Phosphopeptide-amorphous Calcium Phosphate Treatment on Microtensile Bond Strength to Carious Affected Dentin Using Two Adhesive Strategies

    PubMed Central

    Bahari, Mahmoud; Savadi Oskoee, Siavash; Kimyai, Soodabeh; Pouralibaba, Firoz; Farhadi, Farrokh; Norouzi, Marouf

    2014-01-01

    Background and aims. The aim was to evaluate the effect of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) on microtensile bond strength (μTBS) to carious affected dentin (CAD) using etch-and-rinse and self-etch adhesive systems. Materials and methods. The occlusal surface of 32 human molars with moderate occlusal caries was removed. Infected dentin was removed until reaching CAD and the teeth were randomly divided into two groups based on the Single Bond (SB) and Clearfil SE Bond (CSE) adhesive systems. Before composite resin bonding, each group was subdivided into three subgroups of ND, CAD and CPP-ACP-treated CAD (CAD-CPP) based on the dentin substrate. After dissecting samples to l-mm-thick cross-sections (each subgroup: n = 13), μTBS was measured at a strain rate of 0.5 mm/min. Data was analyzed using two-way ANOVA, independent samples t-test and post-hoc Tukey tests (α=0.05). Results. Bond strength of both adhesive systems to ND was significantly higher than that to CAD (P <0.001) and CAD/CPP (P < 0.001). There were no significant differences between the μTBS of SB to CAD and CAD-CPP (P > 0.05).μTBS of CSE to CAD-CPP was higher than that to CAD; however, the difference was not significant (P > 0.05). Significant differences were found between SB and CSE systems only with CAD substrate (P < 0.001). Conclusion. Regardless of the adhesive system used, surface treatment of CAD with CPP-ACP did not have a significant effect on bond strength. However, bond strength to CAD was higher with SB rather than with CSE. PMID:25346832

  12. Assessment of rock musician's efferent system functioning using contralateral suppression of otoacoustic emissions.

    PubMed

    Kumar, Prawin; Grover, Vibhu; Publius A, Sam; Sanju, Himanshu Kumar; Sinha, Sachchidanand

    2016-12-01

    Contralateral suppression of oto acoustic emission (OAE) is referred as activation of efferent system. Previous literature mentioned about the importance of contralateral suppression of OAEs as a tool to assess efferent system in different groups of population. There is dearth of literature to explore the efferent system function in experienced musicians exposed to rock music using TEOAEs and DPOAEs. Two groups of participant (14 rock musicians and 14 non-musicians) in the age range of 18-25 years were involved in the study. Contralateral suppression of TEOAEs and DPOAEs were measured using ILO (Version 6) in both groups. Descriptive statistics showed higher suppression of TEOAEs and DPOAEs in rock-musicians at most of the frequencies in comparison to non-musicians. For DPOAE measures, Mann Whitney U test results revealed significantly greater DPOAE suppression only at 1 kHz and 3 kHz in rock-musicians compared to non-musicians. For within group comparison, Kruskal Wallis test results revealed there were significant difference observed across most of the frequencies i.e. at 1 kHz, 3 kHz and 6 kHz. For TEOAE measures, Mann Whitney U test results revealed that only at 2 kHz, TEOAE suppression in rock-musician was significantly greater compared to non-musicians. Similarly, Kuskal Wallis test results revealed that within group there were no significant differences observed for most of the frequencies except 2 kHz. Based on the above finding, present study concludes that rock musicians are having better efferent system compared to non-musicians. No suppression effect at few frequencies probably indicates more vulnerability at those frequencies. Contralateral suppression of DPOAE shows more significant finding in comparison to contralateral suppression of TEOAEs in present study.

  13. Study on small ruminant lungworms in northeastern Ethiopia.

    PubMed

    Alemu, Sefinew; Leykun, Esayas Gelaye; Ayelet, Gelagay; Zeleke, Aschalew

    2006-12-20

    A cross-sectional study of lungworm infection was carried out with the aim of determining the prevalence of lungworm infection of small ruminants and identifying the species of the respiratory helminthes circulating in six districts of northeastern Ethiopia: Debresina, Legambo, Habru, Kalu, Chaffa-Dawi and Artumana-Fersejelle. Faecal and postmortem examination were conducted from 1162 and 104 animals, respectively. An overall infection rate of 53.6% and 66.3% was found by faecal and postmortem examinations, respectively. Significant difference (p<0.05) was found between areas of different altitude with an infection rate of 30.4%, 32.5% and 71.3% at low, medium and high altitude areas, respectively. Prevalence on the different months was insignificant (p>0.05). The prevalence of Dictyocaulus filaria and Muellerius capillaris infection showed a significant difference (p<0.05) between young, adult and old age groups. The prevalence of D. filaria decreases and that of M. capillaris increase with increasing age of the animal. Animals under relatively good management system have been found less affected with significant difference (p>0.05) than their counterparts at relatively poor management system. The infection rate between male and female animals showed significant difference (p<0.05) with prevalence rate of 44.4% and 59.3%, respectively. A significant difference between sheep and goats was also noted with infection rate of 24.4% and 50.7%, respectively. Monthly worm burden of D. filaria infection showed significant difference (p>0.05) while it was insignificant in case of M. capillaris. Due to its impact on production, emphasis should be given for the control and prevention of lungworm infection in highland areas.

  14. Enhanced top soil carbon stocks under organic farming.

    PubMed

    Gattinger, Andreas; Muller, Adrian; Haeni, Matthias; Skinner, Colin; Fliessbach, Andreas; Buchmann, Nina; Mäder, Paul; Stolze, Matthias; Smith, Pete; Scialabba, Nadia El-Hage; Niggli, Urs

    2012-10-30

    It has been suggested that conversion to organic farming contributes to soil carbon sequestration, but until now a comprehensive quantitative assessment has been lacking. Therefore, datasets from 74 studies from pairwise comparisons of organic vs. nonorganic farming systems were subjected to metaanalysis to identify differences in soil organic carbon (SOC). We found significant differences and higher values for organically farmed soils of 0.18 ± 0.06% points (mean ± 95% confidence interval) for SOC concentrations, 3.50 ± 1.08 Mg C ha(-1) for stocks, and 0.45 ± 0.21 Mg C ha(-1) y(-1) for sequestration rates compared with nonorganic management. Metaregression did not deliver clear results on drivers, but differences in external C inputs and crop rotations seemed important. Restricting the analysis to zero net input organic systems and retaining only the datasets with highest data quality (measured soil bulk densities and external C and N inputs), the mean difference in SOC stocks between the farming systems was still significant (1.98 ± 1.50 Mg C ha(-1)), whereas the difference in sequestration rates became insignificant (0.07 ± 0.08 Mg C ha(-1) y(-1)). Analyzing zero net input systems for all data without this quality requirement revealed significant, positive differences in SOC concentrations and stocks (0.13 ± 0.09% points and 2.16 ± 1.65 Mg C ha(-1), respectively) and insignificant differences for sequestration rates (0.27 ± 0.37 Mg C ha(-1) y(-1)). The data mainly cover top soil and temperate zones, whereas only few data from tropical regions and subsoil horizons exist. Summarizing, this study shows that organic farming has the potential to accumulate soil carbon.

  15. Enhanced top soil carbon stocks under organic farming

    PubMed Central

    Gattinger, Andreas; Muller, Adrian; Haeni, Matthias; Skinner, Colin; Fliessbach, Andreas; Buchmann, Nina; Mäder, Paul; Stolze, Matthias; Smith, Pete; Scialabba, Nadia El-Hage; Niggli, Urs

    2012-01-01

    It has been suggested that conversion to organic farming contributes to soil carbon sequestration, but until now a comprehensive quantitative assessment has been lacking. Therefore, datasets from 74 studies from pairwise comparisons of organic vs. nonorganic farming systems were subjected to metaanalysis to identify differences in soil organic carbon (SOC). We found significant differences and higher values for organically farmed soils of 0.18 ± 0.06% points (mean ± 95% confidence interval) for SOC concentrations, 3.50 ± 1.08 Mg C ha−1 for stocks, and 0.45 ± 0.21 Mg C ha−1 y−1 for sequestration rates compared with nonorganic management. Metaregression did not deliver clear results on drivers, but differences in external C inputs and crop rotations seemed important. Restricting the analysis to zero net input organic systems and retaining only the datasets with highest data quality (measured soil bulk densities and external C and N inputs), the mean difference in SOC stocks between the farming systems was still significant (1.98 ± 1.50 Mg C ha−1), whereas the difference in sequestration rates became insignificant (0.07 ± 0.08 Mg C ha−1 y−1). Analyzing zero net input systems for all data without this quality requirement revealed significant, positive differences in SOC concentrations and stocks (0.13 ± 0.09% points and 2.16 ± 1.65 Mg C ha−1, respectively) and insignificant differences for sequestration rates (0.27 ± 0.37 Mg C ha−1 y−1). The data mainly cover top soil and temperate zones, whereas only few data from tropical regions and subsoil horizons exist. Summarizing, this study shows that organic farming has the potential to accumulate soil carbon. PMID:23071312

  16. Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems.

    PubMed

    Bacher, Klaus; Smeets, Peter; Vereecken, Ludo; De Hauwere, An; Duyck, Philippe; De Man, Robert; Verstraete, Koenraad; Thierens, Hubert

    2006-09-01

    The aim of this study was to compare the image quality and radiation dose in chest imaging using an amorphous silicon flat-panel detector system and an amorphous selenium flat-panel detector system. In addition, the low-contrast performance of both systems with standard and low radiation doses was compared. In two groups of 100 patients each, digital chest radiographs were acquired with either an amorphous silicon or an amorphous selenium flat-panel system. The effective dose of the examination was measured using thermoluminescent dosimeters placed in an anthropomorphic Rando phantom. The image quality of the digital chest radiographs was assessed by five experienced radiologists using the European Guidelines on Quality Criteria for Diagnostic Radiographic Images. In addition, a contrast-detail phantom study was set up to assess the low-contrast performance of both systems at different radiation dose levels. Differences between the two groups were tested for significance using the two-tailed Mann-Whitney test. The amorphous silicon flat-panel system allowed an important and significant reduction in effective dose in comparison with the amorphous selenium flat-panel system (p < 0.0001) for both the posteroanterior and lateral views. In addition, clinical image quality analysis showed that the dose reduction was not detrimental to image quality. Compared with the amorphous selenium flat-panel detector system, the amorphous silicon flat-panel detector system performed significantly better in the low-contrast phantom study, with phantom entrance dose values of up to 135 muGy. Chest radiographs can be acquired with a significantly lower patient radiation dose using an amorphous silicon flat-panel system than using an amorphous selenium flat-panel system, thereby producing images that are equal or even superior in quality to those of the amorphous selenium flat-panel detector system.

  17. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

    PubMed

    Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T

    2008-10-01

    To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.

  18. Color stability of nanocomposites polished with one-step systems.

    PubMed

    Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin

    2008-01-01

    This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.

  19. Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems

    PubMed Central

    2014-01-01

    Background The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion levels and whether there is a difference in the functional outcomes between the systems. Methods In a cross-sectional cohort study, three different metal-on-metal total hip systems were assessed: two monoblock heads, the Durom socket (Zimmer, Warsaw, IN, USA) and the Birmingham socket (Smith and Nephew, Memphis, TN, USA), and one modular metal-on-metal total hip system (Pinnacle, Depuy Orthopedics, Warsaw, IN, USA). Fifty-four patients were recruited, with a mean age of 59.7 years and a mean follow-up time of 41 months (12 to 60). Patients were evaluated clinically, radiologically and biochemically. Statistical analysis was performed on all collected data to assess any differences between the three groups in terms of overall blood metal ion levels and also to identify whether there was any other factor within the group demographics and outcomes that could influence the mean levels of Co and Cr. Results Although the functional outcome scores were similar in all three groups, the blood metal ion levels in the larger monoblock large heads (Durom, Birmingham sockets) were significantly raised compared with those of the Pinnacle group. In addition, the metal ion levels were not found to have a statistically significant relationship to the anteversion or abduction angles as measured on the radiographs. Conclusions When considering a MOM THR, the use of a monoblock large-head system leads to higher elevations in whole blood metal ions and offers no advantage over a smaller head modular system. PMID:24472283

  20. Environmental performances of Sardinian dairy sheep production systems at different input levels.

    PubMed

    Vagnoni, E; Franca, A; Breedveld, L; Porqueddu, C; Ferrara, R; Duce, P

    2015-01-01

    Although sheep milk production is a significant sector for the European Mediterranean countries, it shows serious competitiveness gaps. Minimizing the ecological impacts of dairy sheep farming systems could represent a key factor for farmers to bridging the gaps in competitiveness of such systems and also obtaining public incentives. However, scarce is the knowledge about the environmental performance of Mediterranean dairy sheep farms. The main objectives of this paper were (i) to compare the environmental impacts of sheep milk production from three dairy farms in Sardinia (Italy), characterized by different input levels, and (ii) to identify the hotspots for improving the environmental performances of each farm, by using a Life Cycle Assessment (LCA) approach. The LCA was conducted using two different assessment methods: Carbon Footprint-IPCC and ReCiPe end-point. The analysis, conducted "from cradle to gate", was based on the functional unit 1 kg of Fat and Protein Corrected Milk (FPCM). The observed trends of the environmental performances of the studied farming systems were similar for both evaluation methods. The GHG emissions revealed a little range of variation (from 2.0 to 2.3 kg CO2-eq per kg of FPCM) with differences between farming systems being not significant. The ReCiPe end-point analysis showed a larger range of values and environmental performances of the low-input farm were significantly different compared to the medium- and high-input farms. In general, enteric methane emissions, field operations, electricity and production of agricultural machineries were the most relevant processes in determining the overall environmental performances of farms. Future research will be dedicated to (i) explore and better define the environmental implications of the land use impact category in the Mediterranean sheep farming systems, and (ii) contribute to revising and improving the existing LCA dataset for Mediterranean farming systems. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Reciproc versus Twisted file for root canal filling removal: assessment of apically extruded debris.

    PubMed

    Altunbas, Demet; Kutuk, Betul; Toyoglu, Mustafa; Kutlu, Gizem; Kustarci, Alper; Er, Kursat

    2016-01-01

    The aim of this study was to evaluate the amount of apically extruded debris during endodontic retreatment with different file systems. Sixty extracted human mandibular premolar teeth were used in this study. Root canals of the teeth were instrumented and filled before being randomly assigned to three groups. Guttapercha was removed using the Reciproc system, the Twisted File system (TF), and Hedström-files (H-file). Apically extruded debris was collected and dried in pre-weighed Eppendorf tubes. The amount of extruded debris was assessed with an electronic balance. Data were statistically analyzed using one-way ANOVA, Kruskal-Wallis, and Mann-Whitney U tests. The Reciproc and TF systems extruded significantly less debris than the H-file (p<0.05). However, no significant difference was found between the Reciproc and TF systems. All tested file systems caused apical extrusion of debris. Both the rotary file (TF) and the reciprocating single-file (Reciproc) systems were associated with less apical extrusion compared with the H-file.

  2. More challenges since Wikipedia: the effects of exposure to internet information about the Rorschach on selected comprehensive system variables.

    PubMed

    Schultz, Douglas S; Brabender, Virginia M

    2013-01-01

    To determine the effects of reading the Wikipedia article on the Rorschach on Comprehensive System variables, participants in this study (recruited from parent-teacher associations, online message boards, and graduate schools; N = 50) were provided with either a copy of the Wikipedia article on the Rorschach (from April 2010) or an irrelevant article, then administered the Rorschach and instructed to "fake good." Monetary incentives were used to increase motivation to dissimulate. Initial results indicated that participants given the Wikipedia article produced a lower number of responses (R) and had higher scores on Populars, X+%, XA%, and WDA% as compared to controls. However, post-hoc analyses revealed that when the influence of Populars was controlled, significant differences for X+%, XA%, and WDA% disappeared. No significant differences were found for Form%, Zf, Blends, or PER, although post-hoc analyses controlling for differences in R revealed a significant difference between groups on Zf%. Limitations of the study and implications for clinical and forensic practice are discussed.

  3. Evaluating the usability of speech recognition to create clinical documentation using a commercial electronic health record.

    PubMed

    Hodgson, Tobias; Magrabi, Farah; Coiera, Enrico

    2018-05-01

    To conduct a usability study exploring the value of using speech recognition (SR) for clinical documentation tasks within an electronic health record (EHR) system. Thirty-five emergency department clinicians completed a system usability scale (SUS) questionnaire. The study was undertaken after participants undertook randomly allocated clinical documentation tasks using keyboard and mouse (KBM) or SR. SUS scores were analyzed and the results with KBM were compared to SR results. Significant difference in SUS scores between EHR system use with and without SR were observed (KBM 67, SR 61; P = 0.045; CI, 0.1 to 12.0). Nineteen of 35 participants scored higher for EHR with KBM, 11 higher for EHR with SR and 5 gave the same score for both. Factor analysis showed no significant difference in scores for the sub-element of usability (EHR with KBM 65, EHR with SR 62; P = 0.255; CI, -2.6 to 9.5). Scores for the sub-element of learnability were significantly different (KBM 72, SR 55; P < 0.001; CI, 9.8 to 23.5). A significant correlation was found between the perceived usability of the two system configurations (EHR with KBM or SR) and the efficiency of documentation (time to document) (P = 0.002; CI, 10.5 to -0.1) but not with safety (number of errors) (P = 0.90; CI, -2.3 to 2.6). SR was associated with significantly reduced overall usability scores, even though it is often positioned as ease of use technology. SR was perceived to impose larger costs in terms of learnability via training and support requirements for EHR based documentation when compared to using KBM. Lower usability scores were significantly associated with longer documentation times. The usability of EHR systems with any input modality is an area that requires continued development. The addition of an SR component to an EHR system may cause a significant reduction in terms of perceived usability by clinicians. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

    PubMed Central

    Bastos, Laura Alves; Sousa, Ana Beatriz Silva; Drubi-Filho, Brahim; Panzeri Pires-de-Souza, Fernanda de Carvalho

    2015-01-01

    Objectives The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Results Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Preetching/Silorane and Methacrylate groups. Conclusions Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin. PMID:25671209

  5. How and why do countries differ in their governance and financing-related administrative expenditure in health care? An analysis of OECD countries by health care system typology.

    PubMed

    Hagenaars, Luc L; Klazinga, Niek S; Mueller, Michael; Morgan, David J; Jeurissen, Patrick P T

    2018-01-01

    Administration is vital for health care. Its importance may increase as health care systems become more complex, but academic attention has remained minimal. We investigated trends in administrative expenditure across OECD countries, cross-country spending differences, spending differences between health care system typologies, and differences in the scale and scope of administrative functions across typologies. We used OECD data, which include health system governance and financing-related administrative activities by regulators, governance bodies, and insurers (macrolevel), but exclude administrative expenditure by health care providers (mesolevel and microlevel). We find that governance and financing-related administrative spending at the macrolevel has remained stable over the last decade at slightly over 3% of total health spending. Cross-country differences range from 1.3% of health spending in Iceland to 8.3% in the United States. Voluntary private health insurance bears much higher administrative costs than compulsory schemes in all countries. Among compulsory schemes, multiple payers exhibit significantly higher administrative spending than single payers. Among single-payer schemes, those where entitlements are based on residency have significantly lower administrative spending than those with single social health insurance, albeit with a small difference. These differences can partially be explained because multi-payer and voluntary private health insurance schemes require additional administrative functions and enjoy less economies of scale. Studies in hospitals and primary care indicate similar differences in administrative costs across health system typologies at the mesolevel and microlevel of health care delivery, which warrants more research on total administrative costs at all the levels of health systems. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer

    NASA Astrophysics Data System (ADS)

    Yang, J.; Li, J.; Chen, L.; Price, R.; McNeeley, S.; Qin, L.; Wang, L.; Xiong, W.; Ma, C.-M.

    2005-03-01

    The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (Dmin), the dose received by 98% of the target volume (D98), dose at the isocentre (Diso), mean target dose (Dmean) and the maximum critical structure dose (Dmax) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.

  7. Overview of the health care system in Hong Kong and its referential significance to mainland China.

    PubMed

    Kong, Xiangyi; Yang, Yi; Gao, Jun; Guan, Jian; Liu, Yang; Wang, Renzhi; Xing, Bing; Li, Yongning; Ma, Wenbin

    2015-10-01

    Hong Kong's health system was established within the framework of a perfect market-oriented economic matrix, where there are wide-ranging social security and medical service systems. There are many differences in the economic foundations, social systems, and ideologies between Hong Kong and mainland China, therefore, it would probably be entirely impossible to copy Hong Kong's health care system mode. However, under the framework of one country, two systems, the referential significance of relevant concepts of Hong Kong's medical service system to mainland China cannot be ignored, and merits further study. Copyright © 2015. Published by Elsevier Taiwan.

  8. Characterisation of a hybrid, fuel-cell-based propulsion system for small unmanned aircraft

    NASA Astrophysics Data System (ADS)

    Verstraete, D.; Lehmkuehler, K.; Gong, A.; Harvey, J. R.; Brian, G.; Palmer, J. L.

    2014-03-01

    Advanced hybrid powerplants combining a fuel cell and battery can enable significantly higher endurance for small, electrically powered unmanned aircraft systems, compared with batteries alone. However, detailed investigations of the static and dynamic performance of such systems are required to address integration challenges. This article describes a series of tests used to characterise the Horizon Energy Systems' AeroStack hybrid, fuel-cell-based powertrain. The results demonstrate that a significant difference can exist between the dynamic performance of the fuel-cell system and its static polarisation curve, confirming the need for detailed measurements. The results also confirm that the AeroStack's lithium-polymer battery plays a crucial role in its response to dynamic load changes and protects the fuel cell from membrane dehydration and fuel starvation. At low static loads, the AeroStack fuel cell recharges the battery with currents up to 1 A, which leads to further differences with the polarisation curve.

  9. Concentration of benzoxazinoids in roots of field-grown wheat (Triticum aestivum L.) varieties.

    PubMed

    Stochmal, Anna; Kus, Jan; Martyniuk, Stefan; Oleszek, Wieslaw

    2006-02-22

    Benzoxazinones are naturally occurring secondary metabolites of some Gramineae plants, responsible for their resistance to some pathogenic fungi and for their allelopathic action. Six varieties of winter wheat grown in fields under organic or conventional systems and 11 old accessions were tested for two consecutive seasons and three plant development stages for the concentration in their roots of cyclic hydroxamic acids and their degradation products. This is the first report of six benzoxazinones analyzed in plants grown in the field. An analytical technique employing LC-DAD was used for determination. It was shown that 2,4-dihydroxy-7-methoxy-1,4-benzoxazin-3-one, its degradation product 6-methoxybenzoxazolin-2-one, and the lactam 2-hydroxy-7-methoxy-1,4-benzoxazin-2-one were predominant compounds in all tested samples. Their concentrations significantly differed with plant development stage and season, but no significant differences were found between varieties and between plant cultivation systems. The concentrations of 2,4-dihydroxy-1,4-benzoxazin-3-one (DIBOA) and its degradation product benzoxazolin-2-one (BOA) were much lower, ranging from 60 to 430 mg/kg of dry matter, depending on accession, stage of development, and season. There was no significant difference found between plants grown in different cultivation systems, but there were significant differences between old and new varieties; concentrations of DIBOA and its derivatives were significantly lower in old accessions. It was concluded that the concentrations of DIBOA and BOA, which are precursors of highly fungicidal 2-aminophenol, 2-amino-3H-phenoxazin-3-one, and 2-acetylamino-3H-phenoxazin-3-one, are theoretically high enough to protect plants against some soilborne pathogens.

  10. A Systemic Integration of Technology for New-Paradigm Education

    ERIC Educational Resources Information Center

    Watson, William R.; Watson, Sunnie Lee; Reigeluth, Charles M.

    2012-01-01

    Educational reform efforts have failed to create widespread improvement. The authors argue that rather than trying to improve the existing system of education, a new learner-centered paradigm is needed that supports individualized learning. Such a significantly different system of education will require the systemic application of technology to…

  11. Robot-assisted walking with the Lokomat: the influence of different levels of guidance force on thorax and pelvis kinematics.

    PubMed

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Clijsen, Ron; Beckwée, David; Kerckhofs, Eric

    2015-03-01

    Little attention has been devoted to the thorax and pelvis movements during gait. The aim of this study is to compare differences in the thorax and pelvis kinematics during unassisted walking on a treadmill and during walking with robot assistance (Lokomat-system (Hocoma, Volketswil, Switzerland)). 18 healthy persons walked on a treadmill with and without the Lokomat system at 2kmph. Three different conditions of guidance force (30%, 60% and 100%) were used during robot-assisted treadmill walking (30% body weight support). The maximal movement amplitudes of the thorax and pelvis were measured (Polhemus Liberty™ (Polhemus, Colchester, Vermont, USA) (240/16)). A repeated measurement ANOVA was conducted. Robot-assisted treadmill walking with different levels of guidance force showed significantly smaller maximal movement amplitudes for thorax and pelvis, compared to treadmill walking. Only the antero-posterior tilting of the pelvis was significantly increased during robot-assisted treadmill walking compared to treadmill walking. No significant changes of kinematic parameters were found between the different levels of guidance force. With regard to the thorax and pelvis movements, robot-assisted treadmill walking is significantly different compared to treadmill walking. It can be concluded that when using robot assistance, the thorax is stimulated in a different way than during walking without robot assistance, influencing the balance training during gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Immunoglobulin M monoclonal gammopathies of undetermined significance and indolent Waldenstrom's macroglobulinemia recognize the same determinants of evolution into symptomatic lymphoid disorders: proposal for a common prognostic scoring system.

    PubMed

    Baldini, Luca; Goldaniga, Maria; Guffanti, Andrea; Broglia, Chiara; Cortelazzo, Sergio; Rossi, Andrea; Morra, Enrica; Colombi, Mariangela; Callea, Vincenzo; Pogliani, Enrico; Ilariucci, Fiorella; Luminari, Stefano; Morel, Pierre; Merlini, Giampaolo; Gobbi, Paolo

    2005-07-20

    To evaluate the clinicohematologic variables at diagnosis that are prognostically related to neoplastic progression in patients with immunoglobulin M (IgM) monoclonal gammopathies of undetermined significance (MGUS), and indolent Waldenström's macroglobulinemia (IWM), and propose a scoring system to identify subsets of patients at different risk. We evaluated 217 patients with IgM MGUS and 201 with IWM (male-female ratio, 131:86 and 117:84; mean age, 63.7 and 63.6 years, respectively) diagnosed on the basis of serum monoclonal component (MC) levels and bone marrow lymphoplasmacytic infiltration degree. The variables selected by univariate analyses were multivariately investigated; on the basis of their individual relative hazards, a scoring system was devised to identify subsets of patients at different risk of evolution. After a median follow-up of 56.1 and 60.2 months, 15 of 217 MGUS and 45 of 201 IWM patients, respectively, required chemotherapy for symptomatic WM (13 and 36), non-Hodgkin's lymphoma (2 and 6) and amyloidosis (0 and 3). The median time to evolution (TTE) was not reached for MGUS and was 141.5 months for IWM. The variables adversely related to evolution were qualitatively the same in both groups: MC levels, Hb concentrations and sex. A scoring system based on these parameters identified three risk groups with highly significant differences in TTE in both groups (P < .0001). MGUS and IWM identify disease entities with different propensities for symptomatic neoplastic evolution. As both have the same prognostic determinants of progression, we propose a practical scoring system that, identifying different risks of malignant evolution, may allow an individualized clinical approach.

  13. Comparison of Chemical Binding to Recombinant Fathead minnow and Human Estrogen Receptor alpha (ERα) in Whole Cell and Cell-Free Assay Systems.

    EPA Science Inventory

    Our objectives were to assess whether binding of chemicals differs significantly between recombinant estrogen receptors from fathead minnow (fhERα) and human (hERα) and to evaluate the performance of these receptors using two different in vitro assay systems: a COS whole cell bin...

  14. Energy cost of riding bicycles with shock absorption systems on a flat surface.

    PubMed

    Nielens, H; Lejeune, T M

    2001-08-01

    Bike shock absorption systems reduce the energy variation induced by terrain irregularities, leading to a greater comfort. However, they may also induce an increase in energy expenditure for the rider. More specifically, cross-country racers claim that rear shock absorption systems generate significant energy loss. The energy losses caused by such systems may be divided in terrain-induced or rider-induced. This study aims at evaluating the rider-induced energy loss of modern suspended bicycles riding on a flat surface. Twelve experienced competitive racers underwent three multistage gradational tests (50 to 250 W) on a cross-country bicycle mounted on an electromagnetically braked cycle ergometer. Three different tests were performed on a fully suspended bike, front suspended and non-suspended bicycle, respectively. The suspension mode has no significant effect on VO2. The relative difference of VO2 between the front-suspended or full-suspended bike and the rigid bike reaches a non significant maximum of only 3%. The claims of many competitors who still prefer front shock absorption systems could be related to a possible significant energy loss that could be present at powers superior to 250 W or when they stand on the pedals. It could also be generated by terrain-induced energy loss.

  15. Effect of simulated weightlessness on the immune system in rats

    NASA Technical Reports Server (NTRS)

    Caren, L. D.; Mandel, A. D.; Nunes, J. A.

    1980-01-01

    Rats suspended in a model system designed to simulate many aspects of weightlessness were immunized with sheep red blood cells. Parameters measured on these and control rats included titers of anti-sheep red blood cell antibodies, serum immunoglobulin levels, spleen and thymus weights, hematocrits, and leukocyte differential counts on peripheral blood. No significant differences were found between test and weight-bearing, harnessed controls; however, the thymuses of animals in both these groups were significantly smaller than untreated cage controls. The lack of an effect of simulated weightlessness on the immune system is an interesting result, and its significance is discussed.

  16. Present status of metrology of electro-optical surveillance systems

    NASA Astrophysics Data System (ADS)

    Chrzanowski, K.

    2017-10-01

    There has been a significant progress in equipment for testing electro-optical surveillance systems over the last decade. Modern test systems are increasingly computerized, employ advanced image processing and offer software support in measurement process. However, one great challenge, in form of relative low accuracy, still remains not solved. It is quite common that different test stations, when testing the same device, produce different results. It can even happen that two testing teams, while working on the same test station, with the same tested device, produce different results. Rapid growth of electro-optical technology, poor standardization, limited metrology infrastructure, subjective nature of some measurements, fundamental limitations from laws of physics, tendering rules and advances in artificial intelligence are major factors responsible for such situation. Regardless, next decade should bring significant improvements, since improvement in measurement accuracy is needed to sustain fast growth of electro-optical surveillance technology.

  17. Review: Intracardiac intracellular angiotensin system in diabetes

    PubMed Central

    Kumar, Rajesh; Yong, Qian Chen; Thomas, Candice M.

    2012-01-01

    The renin-angiotensin system (RAS) has mainly been categorized as a circulating and a local tissue RAS. A new component of the local system, known as the intracellular RAS, has recently been described. The intracellular RAS is defined as synthesis and action of ANG II intracellularly. This RAS appears to differ from the circulating and the local RAS, in terms of components and the mechanism of action. These differences may alter treatment strategies that target the RAS in several pathological conditions. Recent work from our laboratory has demonstrated significant upregulation of the cardiac, intracellular RAS in diabetes, which is associated with cardiac dysfunction. Here, we have reviewed evidence supporting an intracellular RAS in different cell types, ANG II's actions in cardiac cells, and its mechanism of action, focusing on the intracellular cardiac RAS in diabetes. We have discussed the significance of an intracellular RAS in cardiac pathophysiology and implications for potential therapies. PMID:22170614

  18. Vibrations Generated by Several Nickel-titanium Endodontic File Systems during Canal Shaping in an Ex Vivo Model.

    PubMed

    Choi, Dong-Min; Kim, Jin-Woo; Park, Se-Hee; Cho, Kyung-Mo; Kwak, Sang Won; Kim, Hyeon-Cheol

    2017-07-01

    This study aimed to compare the vibration generated by several nickel-titanium (NiTi) file systems and transmitted to teeth under 2 different motions (continuous rotation motion and reciprocating motion). Sixty J-shaped resin blocks (Endo Training Bloc-J; Dentsply Maillefer, Ballaigues, Switzerland) were trimmed to a root-shaped form and divided into 2 groups according to the types of electric motors: WaveOne motor (WOM, Dentsply Maillefer) and X-Smart Plus motor (XSM, Dentsply Maillefer). Each group was further subdivided into 3 subgroups (n = 10 each) according to the designated file systems: ProTaper Next (PTN, Dentsply Maillefer), ProTaper Universal (PTU, Dentsply Maillefer), and WaveOne (WOP, Dentsply Maillefer) systems. Vibration was measured during the pecking motion using an accelerometer attached to a predetermined consistent position. The average vibration values were subjected to 2-way analysis of variance as well as the t test and Duncan test for post hoc comparison at the 95% confidence interval. Both motor types and instrument types produced significantly different ranges of average vibrations. Regardless of the instrument types, the WOM group generated greater vibration than the XSM group (P < .05). Although PTN and PTU did not show significant differences, the WOP group showed significantly greater vibration than the other groups regardless of motor types (P < .05). Under the limitations of this study design, the reciprocating NiTi file system may generate greater vibration than the continuous rotation NiTi file systems. The motor type also has a significant effect to amplify the vibrations. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Atrial Fibrillation Ablation Guided by a Novel Nonfluoroscopic Navigation System.

    PubMed

    Ballesteros, Gabriel; Ramos, Pablo; Neglia, Renzo; Menéndez, Diego; García-Bolao, Ignacio

    2017-09-01

    Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures. This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity). The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications. The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Depth of Etch Comparison Between Self-limiting and Traditional Etchant Systems

    DTIC Science & Technology

    2016-06-18

    two different etchants (Ultradent’s Opal Etch 35%, a self-limiting phosphoric acid, or 34% Tooth Conditioning Gel by Dentsply) at varied time... Opal versus Dentsply and there was also a significant difference between etch time. There is no significant difference between the interaction of...etch material and etch time. Conclusion: The depth of etch of Opal etchant was consistently less than Dentsply etchant but continued to etch and

  1. An Evaluation of Color Sets for CRT Displays

    DTIC Science & Technology

    1985-12-31

    color sets covered a wide range in color difference values (AE* in CIELUV , 1976). Performance with some color sets was significantly better than that...difference value, AE*. This value, Part of the 1976 CIELUV system, is an estimate of the perceptual color difference between any two colors of known...1:* in CIELUV , 1976). Performance with some color sets was significantly better than that with others on a task where color discrimination was

  2. Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: A CBCT and dental cast study

    PubMed Central

    de Almeida, Marcio Rodrigues; Futagami, Cristina; Conti, Ana Cláudia de Castro Ferreira; Oltramari-Navarro, Paula Vanessa Pedron; Navarro, Ricardo de Lima

    2015-01-01

    OBJECTIVE: The aim of the present study was to compare dentoalveolar changes in mandibular arch, regarding transversal measures and buccal bone thickness, in patients undergoing the initial phase of orthodontic treatment with self-ligating or conventional bracket systems. METHODS: A sample of 25 patients requiring orthodontic treatment was assessed based on the bracket type. Group 1 comprised 13 patients bonded with 0.022-in self-ligating brackets (SLB). Group 2 included 12 patients bonded with 0.022-in conventional brackets (CLB). Cone-beam computed tomography (CBCT) scans and a 3D program (Dolphin) assessed changes in transversal width of buccal bone (TWBB) and buccal bone thickness (BBT) before (T1) and 7 months after treatment onset (T2). Measurements on dental casts were performed using a digital caliper. Differences between and within groups were analyzed by Student's t-test; Pearson correlation coefficient was also calculated. RESULTS: Significant mandibular expansion was observed for both groups; however, no significant differences were found between groups. There was significant decrease in mandibular buccal bone thickness and transversal width of buccal bone in both groups. There was no significant correlation between buccal bone thickness and dental arch expansion. CONCLUSIONS: There were no significant differences between self-ligating brackets and conventional brackets systems regarding mandibular arch expansion and changes in buccal bone thickness or transversal width of buccal bone. PMID:26154456

  3. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  4. The impact of peasant and industrialized agricultural systems on high productive loess soils in Central Europe

    NASA Astrophysics Data System (ADS)

    Schneider, Christian; Heinrich, Jürgen

    2017-04-01

    The study analyzes the impact of a peasant and an industrialized agricultural land use system on soil degradation in two loess landscapes. The comparative method aims to test the hypothesis that different agricultural systems cause distinct differences in soil properties that can be documented by geo-chemical soil analysis. The two loess landscapes under investigation show great similarities in natural geo-ecological properties. Nevertheless, the land use system makes a significant difference in both research areas. The Polish Proszowice Plateau is characterized by traditional small-scale peasant agriculture. Small plots and fragmented ownership make it difficult to conjointly manage soil erosion. However, the Middle Saxonian Loess Region in Germany represents loess landscapes whose ecological functions were shaped by land consolidation measures resulting in the large-scale, high-input farming system. To identify representative small catchments for soil sampling relief heterogeneity analyses and a cluster analysis were performed to bridge scales between the landscape and the sub-catchment level. Geo-physical and geo-chemical laboratory techniques were used to analyze major soil properties. A total number of 346 sites were sampled and analyzed for geo-ecological, geomorphological, and pedological features. The results show distinct differences in soil properties between the two loess landscapes strongly influenced by agricultural use. However, despite big differences in agricultural management great similarities can also be found especially for mean soil organic carbon contents and plant nutrient values. At the same time, the greater variability of the soil mosaic is depicted by a higher variance of almost all soil properties common to traditional land use systems. Topsoils on arable land at the Proszowice Plateau also show a wider C/N ratio. Therefore, the soils there are less prone to degradation through mineralization of humic substances. The wider ratio is mainly caused by lower inputs of N-fertilizers, at least since 1990. At the same time, soil cultivation techniques and atmospheric deposits are not likely to make a significant difference. The topsoil horizons on arable lands at the Proszowice Plateau do not show significant differences in plant available nutrients like phosphorus, despite much lower P-inputs through mineral fertilizers since 1990. This is because of the high P-sorption capacity of the loess soils. Therefore, a long legacy effect of previous comparatively high mineral P-inputs between the 1960s and 80s can be observed. A similar effect occurs in the Middle Saxonian Loess Region. In contrast to the assumption of many scholars small-scale farming at the Proszowice Plateau has not lead to an under-supply of plant nutrients. The study has shown that significant differences in major soil properties can be observed because of different fertilizer inputs and partly because of different cultivation techniques. Also the traditional system increases soil heterogeneity. Contrary to expectations the study has shown that the small-scale peasant farming system resulted in similar mean soil organic carbon and phosphorus contents like the industrialized high-input farming system. A further study could include investigations of the effects of soil amendments like herbicides and pesticide on soil degradation.

  5. A comparison study of different facial soft tissue analysis methods.

    PubMed

    Kook, Min-Suk; Jung, Seunggon; Park, Hong-Ju; Oh, Hee-Kyun; Ryu, Sun-Youl; Cho, Jin-Hyoung; Lee, Jae-Seo; Yoon, Suk-Ja; Kim, Min-Soo; Shin, Hyo-Keun

    2014-07-01

    The purpose of this study was to evaluate several different facial soft tissue measurement methods. After marking 15 landmarks in the facial area of 12 mannequin heads of different sizes and shapes, facial soft tissue measurements were performed by the following 5 methods: Direct anthropometry, Digitizer, 3D CT, 3D scanner, and DI3D system. With these measurement methods, 10 measurement values representing the facial width, height, and depth were determined twice with a one week interval by one examiner. These data were analyzed with the SPSS program. The position created based on multi-dimensional scaling showed that direct anthropometry, 3D CT, digitizer, 3D scanner demonstrated relatively similar values, while the DI3D system showed slightly different values. All 5 methods demonstrated good accuracy and had a high coefficient of reliability (>0.92) and a low technical error (<0.9 mm). The measured value of the distance between the right and left medial canthus obtained by using the DI3D system was statistically significantly different from that obtained by using the digital caliper, digitizer and laser scanner (p < 0.05), but the other measured values were not significantly different. On evaluating the reproducibility of measurement methods, two measurement values (Ls-Li, G-Pg) obtained by using direct anthropometry, one measurement value (N'-Prn) obtained by using the digitizer, and four measurement values (EnRt-EnLt, AlaRt-AlaLt, ChRt-ChLt, Sn-Pg) obtained by using the DI3D system, were statistically significantly different. However, the mean measurement error in every measurement method was low (<0.7 mm). All measurement values obtained by using the 3D CT and 3D scanner did not show any statistically significant difference. The results of this study show that all 3D facial soft tissue analysis methods demonstrate favorable accuracy and reproducibility, and hence they can be used in clinical practice and research studies. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Effects of implant system, impression technique, and impression material on accuracy of the working cast.

    PubMed

    Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd

    2013-01-01

    This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.

  7. The Effect of Canal Preparation with Four Different Rotary Systems on Formation of Dentinal Cracks: An In Vitro Evaluation.

    PubMed

    Khoshbin, Elham; Donyavi, Zakiyeh; Abbasi Atibeh, Erfan; Roshanaei, Ghodratollah; Amani, Faranak

    2018-01-01

    Endodontic rotary systems may result in dentinal cracks. They may propagate to vertical root fracture that compromises the outcome of endodontic treatment. This study aimed to compare Neolix and Reciproc (single-file systems), Mtwo and ProTaper (conventional rotary systems) in terms of dentinal crack formation in root canal walls. This in vitro study was conducted on 110 extracted human single-rooted teeth. The teeth were randomly divided into four experimental groups ( n =25) for root canal preparation with Neolix, Reciproc, Mtwo and ProTaper systems and two control groups ( n =5). The first control group underwent root canal instrumentation with hand files while the second control group received no preparation and was only irrigated. After instrumentation, root canals were horizontally sectioned at 3, 6 and 9 mm from the apex and inspected under a stereomicroscope under 12× magnification for detection of cracks. The data were analyzed using Chi-square, GEE test and Bonferroni tests ( P <0.05). No crack was found in the control groups. All rotary systems caused dentinal cracks. ProTaper, Reciproc, Mtwo and Neolix caused cracks in 92%, 80%, 68% and 48% of samples. ProTaper caused significantly more cracks than Neolix and Mtwo ( P <0.05). No significant differences were noted between other groups ( P >0.05). All rotary systems cause dentinal cracks and it is significantly different in apical, middle and coronal third of the root. Neolix appears to be a suitable alternative to other rotary systems since use of this single-file system saves time and cost and minimizes trauma to dentinal walls.

  8. The Effect of Canal Preparation with Four Different Rotary Systems on Formation of Dentinal Cracks: An In Vitro Evaluation

    PubMed Central

    Khoshbin, Elham; Donyavi, Zakiyeh; Abbasi Atibeh, Erfan; Roshanaei, Ghodratollah; Amani, Faranak

    2018-01-01

    Introduction: Endodontic rotary systems may result in dentinal cracks. They may propagate to vertical root fracture that compromises the outcome of endodontic treatment. This study aimed to compare Neolix and Reciproc (single-file systems), Mtwo and ProTaper (conventional rotary systems) in terms of dentinal crack formation in root canal walls. Methods and Materials: This in vitro study was conducted on 110 extracted human single-rooted teeth. The teeth were randomly divided into four experimental groups (n=25) for root canal preparation with Neolix, Reciproc, Mtwo and ProTaper systems and two control groups (n=5). The first control group underwent root canal instrumentation with hand files while the second control group received no preparation and was only irrigated. After instrumentation, root canals were horizontally sectioned at 3, 6 and 9 mm from the apex and inspected under a stereomicroscope under 12× magnification for detection of cracks. The data were analyzed using Chi-square, GEE test and Bonferroni tests (P<0.05). Results: No crack was found in the control groups. All rotary systems caused dentinal cracks. ProTaper, Reciproc, Mtwo and Neolix caused cracks in 92%, 80%, 68% and 48% of samples. ProTaper caused significantly more cracks than Neolix and Mtwo (P<0.05). No significant differences were noted between other groups (P>0.05). Conclusion: All rotary systems cause dentinal cracks and it is significantly different in apical, middle and coronal third of the root. Neolix appears to be a suitable alternative to other rotary systems since use of this single-file system saves time and cost and minimizes trauma to dentinal walls. PMID:29707009

  9. Comparison of rankings for lean meat based on results from a CT scanner and a video image analysis system.

    PubMed

    Jay, N P; van de Ven, R J; Hopkins, D L

    2014-10-01

    Coopworth cross lambs born over three years were examined in this study. Differences between two machines; a computer tomography (CT) scanner and a VIAScan® system for the estimation of carcase lean weight in lamb carcases was examined. The CT scanner provided a significantly higher estimate of carcase lean. The rank correlation (0.84) between the CT scanner and the VIAScan® system for the prediction of carcase lean was significant, but there was a different ranking for carcase lean depending on which machine was used. This has important ramifications for the use of VIAScan® data in the New Zealand Sheep Improvement Ltd genetic programme. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Effect of ultrasonic, sonic and rotating-oscillating powered toothbrushing systems on surface roughness and wear of white spot lesions and sound enamel: An in vitro study.

    PubMed

    Hernandé-Gatón, Patrícia; Palma-Dibb, Regina Guenka; Silva, Léa Assed Bezerra da; Faraoni, Juliana Jendiroba; de Queiroz, Alexandra Mussolino; Lucisano, Marília Pacífico; Silva, Raquel Assed Bezerra da; Nelson Filho, Paulo

    2018-04-01

    To evaluate the effect of ultrasonic, sonic and rotating-oscillating powered toothbrushing systems on surface roughness and wear of white spot lesions and sound enamel. 40 tooth segments obtained from third molar crowns had the enamel surface divided into thirds, one of which was not subjected to toothbrushing. In the other two thirds, sound enamel and enamel with artificially induced white spot lesions were randomly assigned to four groups (n=10) : UT: ultrasonic toothbrush (Emmi-dental); ST1: sonic toothbrush (Colgate ProClinical Omron); ST2: sonic toothbrush (Sonicare Philips); and ROT: rotating-oscillating toothbrush (control) (Oral-B Professional Care Triumph 5000 with SmartGuide). The specimens were analyzed by confocal laser microscopy for surface roughness and wear. Data were analyzed statistically by paired t-tests, Kruskal-Wallis, two-way ANOVA and Tukey's post-test (α= 0.05). The different powered toothbrushing systems did not cause a significant increase in the surface roughness of sound enamel (P> 0.05). In the ROT group, the roughness of white spot lesion surface increased significantly after toothbrushing and differed from the UT group (P< 0.05). In the ROT group, brushing promoted a significantly greater wear of white spot lesion compared with sound enamel, and this group differed significantly from the ST1 group (P< 0.05). None of the powered toothbrushing systems (ultrasonic, sonic and rotating-oscillating) caused significant alterations on sound dental enamel. However, conventional rotating-oscillating toothbrushing on enamel with white spot lesion increased surface roughness and wear. None of the powered toothbrushing systems (ultrasonic, sonic and rotating-oscillating) tested caused significant alterations on sound dental enamel. However, conventional rotating-oscillating toothbrushing on enamel with white spot lesion increased surface roughness and wear. Copyright©American Journal of Dentistry.

  11. Overview of the Altair Lunar Lander Thermal Control System Design

    NASA Technical Reports Server (NTRS)

    Stephan, Ryan A.

    2010-01-01

    NASA's Constellation Program has been developed to successfully return humans to the Lunar surface by 2020. The Constellation Program includes several different project offices including Altair, which is the next generation Lunar Lander. The planned Altair missions are very different than the Lunar missions accomplished during the Apollo era. These differences have resulted in a significantly different thermal control system architecture. The current paper will summarize the Altair mission architecture and the various operational phases. In addition, the derived thermal requirements will be presented. The paper will conclude with a brief description of the thermal control system designed to meet these unique and challenging thermal requirements.

  12. A Retrospective Survival Analysis of Anatomic and Prognostic Stage Group Based on the American Joint Committee on Cancer 8th Edition Cancer Staging Manual in Luminal B Human Epidermal Growth Factor Receptor 2-negative Breast Cancer.

    PubMed

    Xu, Ling; Li, Jiang-Hong; Ye, Jing-Ming; Duan, Xue-Ning; Cheng, Yuan-Jia; Xin, Ling; Liu, Qian; Zhou, Bin; Liu, Yin-Hua

    2017-08-20

    Current understanding of tumor biology suggests that breast cancer is a group of diseases with different intrinsic molecular subtypes. Anatomic staging system alone is insufficient to provide future outcome information. The American Joint Committee on Cancer (AJCC) expert panel updated the 8th edition of the staging manual with prognostic stage groups by incorporating biomarkers into the anatomic stage groups. In this study, we retrospectively analyzed the data from our center in China using the anatomic and prognostic staging system based on the AJCC 8th edition staging manual. We reviewed the data from January 2008 to December 2014 for cases with Luminal B Human Epidermal Growth Factor Receptor 2 (HER2)-negative breast cancer in our center. All cases were restaged using the AJCC 8th edition anatomic and prognostic staging system. The Kaplan-Meier method and log-rank test were used to compare the survival differences between different subgroups. SPSS software version 19.0 (IBM Corp., Armonk, NY, USA) was used for the statistical analyses. This study consisted of 796 patients with Luminal B HER-negative breast cancer. The 5-year disease-free survival (DFS) of 769 Stage I-III patients was 89.7%, and the 5-year overall survival (OS) of all 796 patients was 91.7%. Both 5-year DFS and 5-year OS were significantly different in the different anatomic and prognostic stage groups. There were 372 cases (46.7%) assigned to a different group. The prognostic Stage II and III patients restaged from anatomic Stage III had significant differences in 5-year DFS (χ2 = 11.319, P= 0.001) and 5-year OS (χ2 = 5.225, P= 0.022). In addition, cases restaged as prognostic Stage I, II, or III from the anatomic Stage II group had statistically significant differences in 5-year DFS (χ2 = 6.510, P= 0.039) but no significant differences in 5-year OS (χ2 = 5.087, P= 0.079). However, the restaged prognostic Stage I and II cases from anatomic Stage I had no statistically significant differences in either 5-year DFS (χ2 = 0.440, P= 0.507) or 5-year OS (χ2 = 1.530, P= 0.216). The prognostic staging system proposed in the AJCC 8th edition refines the anatomic stage group in Luminal B HER2-negative breast cancer and will lead to a more personalized approach to breast cancer treatment.

  13. A comparison of outcomes according to different diagnostic systems for delirium (DSM-5, DSM-IV, CAM, and DRS-R98).

    PubMed

    Adamis, Dimitrios; Meagher, David; Rooney, Siobhan; Mulligan, Owen; McCarthy, Geraldine

    2018-04-01

    ABSTRACTStudies indicate that DSM-5 criteria for delirium are relatively restrictive, and identify different cases of delirium compared with previous systems. We evaluate four outcomes of delirium (mortality, length of hospital stay, institutionalization, and cognitive improvement) in relation to delirium defined by different DSM classification systems.Prospective, longitudinal study of patients aged 70+ admitted to medical wards of a general hospital. Participants were assessed up to a maximum of four times during two weeks, using DSM-5 and DSM-IV criteria, DRS-R98 and CAM scales as proxies for DSM III-R and DSM III.Of the 200 assessed patients (mean age 81.1, SD = 6.5; and 50% female) during hospitalization, delirium was identified in 41 (20.5%) using DSM-5, 45 (22.5%) according to DSM-IV, 46 (23%) with CAM positive, and 37 (18.5%) with DRS-R98 severity score >15. Mortality was significantly associated with delirium according to any classification system, but those identified with DSM-5 were at greater risk. Length of stay was significantly longer for those with DSM-IV delirium. Discharge to a care home was associated only with DRS-R98 defined delirium. Cognitive improvement was only associated with CAM and DSM-IV. Different classification systems for delirium identify populations with different outcomes.

  14. [Neuroendocrine neoplasm of digestive system with different grades: a clinicopathologic and prognostic study].

    PubMed

    Zhang, Ming-hui; Liu, Yan-hui; Luo, Xin-lan; Lin, Xing-tao; Zhuang, Heng-guo

    2012-07-01

    To study the clinicopathologic and prognostic features of neuroendocrine neoplasm of digestive system with different grades. The clinicopathologic features of 139 cases of neuroendocrine neoplasm occurring in digestive system were retrospectively reviewed and graded according to the 2010 World Health Organization classification of tumours of the digestive system. Immunohistochemical study for synaptophysin, chromogranin A and Ki-67 was carried out. The follow-up and survival data were analysed using Kaplan-Meier method. Prognostic factors were tested by Log-rank testing and independent risk factors were analysed using Cox regression model. Amongst the 139 cases studied, there were 88 cases (63.3%) of grade 1 tumors, 9 cases (6.5%) of grade 2 tumors and 42 cases (30.2%) of grade 3 tumors. There was diffusely positive staining for synaptophysin and chromogranin A in most of the grade 1 and grade 2 tumors. The staining in grade 3 tumors however was focal (P < 0.05). The differences in tumor size, depth of invasion, presence of tumor emboli, perineural permeation, nodal involvement, distant metastasis and survival rate amongst the three groups was statistically significant (P < 0.05). There is significant difference in the clinicopathologic and prognostic features of neuroendocrine neoplasm of digestive system with different grades. It is considered as an independent prognostic factor and represents a useful tool for prognostic evaluation of such tumors, both in clinical practice and research.

  15. Three-Dimensional Accuracy of Digital Static Interocclusal Registration by Three Intraoral Scanner Systems.

    PubMed

    Wong, Kuan Yee; Esguerra, Roxanna Jean; Chia, Vanessa Ai Ping; Tan, Ying Han; Tan, Keson Beng Choon

    2018-02-01

    Prior studies have defined the accuracy of intraoral scanner (IOS) systems but the accuracy of the digital static interocclusal registration function of these systems has not been reported. This study compared the three-dimensional (3D) accuracy of the digital static interocclusal registration of 3 IOS systems using the buccal bite scan function. Three IOS systems compared were 3M TM True Definition Scanner (TDS), TRIOS Color (TRC), and CEREC AC with CEREC Omnicam (CER). Using each scanner, 7 scans (n = 7) of the mounted and articulated SLA master models were obtained. The measurement targets (SiN reference spheres and implant abutment analogs) were in the opposing models at the right (R), central (C), and left (L) regions; abutments #26 and #36, respectively. A coordinate measuring machine with metrology software compared the physical and virtual targets to derive the global 3D linear distortion between the centroids of the respective target reference spheres and abutment analogs (dR R , dR C , dR L , and dR M ) and 2D distances between the pierce points of the abutment analogs (dX M , dY M , dZ M ), with 3 measurement repetitions for each scan. Mean 3D distortion ranged from -471.9 to 31.7 μm for dR R , -579.0 to -87.0 μm for dR C , -381.5 to 69.4 μm for dR L , and -184.9 to -23.1 μm for dR M . Mean 2D distortion ranged from -225.9 to 0.8 μm for dX M , -130.6 to -126.1 μm for dY M , and -34.3 to 26.3 μm for dZ M . Significant differences were found for interarch distortions across the three systems. For dR R and dR L , all three test groups were significantly different, whereas for dR C , the TDS was significantly different from the TRC and CER. For 2D distortion, significant differences were found for dX M only. Interarch and global interocclusal distortions for the three IOS systems were significantly different. TRC performed overall the best and TDS was the worst. The interarch (dR R , dR C , dR L ) and interocclusal (dX M ) distortions observed will affect the magnitude of occlusal contacts of restorations clinically. The final restoration may be either hyperoccluded or infraoccluded, requiring compensations during the CAD design stage or clinical adjustments at issue. © 2017 by the American College of Prosthodontists.

  16. Effects of different root canal obturation techniques on bacterial penetration.

    PubMed

    Yücel, Ali Cağin; Ciftçi, Alper

    2006-10-01

    The aim of this study was to compare bacterial penetration following obturation with 5 different techniques. This study was performed on 120 teeth including negative control (n = 10), positive control (n = 10), and experimental groups (n = 100). One hundred teeth were randomly divided into 5 groups of 20 teeth each and obturated with System B (Sb), Lateral Compaction (Lc), Thermafil (T), Single ProTaper Gutta-percha (P), and laterally compacted ProTaper Gutta-percha (PLc). Enterococcus faecalis was used for determination of the bacterial penetration. Evaluation was carried out for 60 days. At 30 days, the chi2 test showed that the slowest penetration was observed in Group Sb and Group PLc, which were not significantly different from each other. The fastest penetration in the all experimental groups was observed in Group T and Group P, which were not significantly different from one another. Also, there was no statistically significance difference (P > .05) among all groups at 60 days. It may be concluded that under the conditions of this study System B and laterally compacted ProTaper Gutta-percha prevent bacterial penetration of the root canal at 30 days. Furthermore, there was no difference among obturation techniques at 60 days.

  17. A Comparative Study of Shaping Ability of four Rotary Systems.

    PubMed

    Rubio, Jorge; Zarzosa, José Ignacio; Pallarés, Antonio

    2015-12-01

    This study compared the cutting area, instrumentation time, root canal anatomy preservation and non-instrumented areas obtained by F360(®), Mtwo(®), RaCe(®) and Hyflex(®) files with ISO size 35. 120 teeth with a single straight root and root canal were divided into 4 groups. Working length was calculated by using X-rays. The teeth were sectioned with a handpiece and a diamond disc, and the sections were observed with Nikon SMZ-2T stereoscopic microscope and an Intralux 4000-1 light source. The groups were adjusted with a preoperative analysis with AutoCAD. The teeth were reconstructed by a #10 K-File and epoxy glue. Each group was instrumented with one of the four file systems. The instrumentation time was calculated with a 1/100 second chronometer. The area of the thirds and root canal anatomy preservation were analyzed with AutoCAD 2013 and the non-instrumented areas with AutoCAD 2013 and SMZ-2T stereoscopic microscope. The statistical analysis was made with Levene's Test, ANOVA, Bonferroni Test and Pearson´s Chi-square. Equal variances were shown by Levene's Test (P > 0.05). ANOVA (P > 0.05) showed the absence of significant differences. There were significant differences in the instrumentation time (P < 0.05). For root canal anatomy preservation and non-instrumented areas, there were no significant differences between all systems (P > 0.05). The 4 different rotary systems produced similar cutting area, root canal anatomy preservation and non-instrumented areas. Regarding instrumentation time, F360(®) was the fastest system statistically.

  18. A Comparative Study of Shaping Ability of four Rotary Systems

    PubMed Central

    Zarzosa, José Ignacio; Pallarés, Antonio

    2015-01-01

    Purpose This study compared the cutting area, instrumentation time, root canal anatomy preservation and non-instrumented areas obtained by F360®, Mtwo®, RaCe® and Hyflex® files with ISO size 35. Material and Methods 120 teeth with a single straight root and root canal were divided into 4 groups. Working length was calculated by using X-rays. The teeth were sectioned with a handpiece and a diamond disc, and the sections were observed with Nikon SMZ-2T stereoscopic microscope and an Intralux 4000-1 light source. The groups were adjusted with a preoperative analysis with AutoCAD. The teeth were reconstructed by a #10 K-File and epoxy glue. Each group was instrumented with one of the four file systems. The instrumentation time was calculated with a 1/100 second chronometer. The area of the thirds and root canal anatomy preservation were analyzed with AutoCAD 2013 and the non-instrumented areas with AutoCAD 2013 and SMZ-2T stereoscopic microscope. The statistical analysis was made with Levene’s Test, ANOVA, Bonferroni Test and Pearson´s Chi-square. Results Equal variances were shown by Levene’s Test (P > 0.05). ANOVA (P > 0.05) showed the absence of significant differences. There were significant differences in the instrumentation time (P < 0.05). For root canal anatomy preservation and non-instrumented areas, there were no significant differences between all systems (P > 0.05). Conclusions The 4 different rotary systems produced similar cutting area, root canal anatomy preservation and non-instrumented areas. Regarding instrumentation time, F360® was the fastest system statistically. PMID:27688412

  19. An analysis of student performance benchmarks in dental hygiene via distance education.

    PubMed

    Olmsted, Jodi L

    2010-01-01

    Three graduate programs, 35 undergraduate programs and 12 dental hygiene degree completion programs in the United States use varying forms of Distance Learning (DL). Relying heavily on DL leaves an unanswered question: Is learner performance on standard benchmark assessments impacted when using technology as a delivery system? A 10 year, longitudinal examination looked for student performance differences in a Distance Education (DE) dental hygiene program. The purpose of this research was to determine if there was a difference in performance between learners taught in a traditional classroom as compared to their counterparts taking classes through an alternative delivery system. A longitudinal, ex post facto design was used. Two hundred and sixty-six subject records were examined. Seventy-seven individuals (29%) were lost through attrition over 10 years. One hundred and eighty-nine records were used as the study sample, 117 individuals were located face-to-face and 72 were at a distance. Independent variables included time and location, while the dependent variables included course grades, grade point average (GPA) and the National Board of Dental Hygiene Examination (NBDHE). Three research questions were asked: Were there statistically significant differences in learner performance on the National Board of Dental Hygiene Examination (NBDHE)? Were there statistically significant differences in learner performance when considering GPAs? Did statistically significant differences in performance exist relating to individual course grades? T-tests were used for data analysis in answering the research questions. From a cumulative perspective, no statistically significant differences were apparent for the NBDHE and GPAs or for individual courses. Interactive Television (ITV), the synchronous DL system examined, was considered effective for delivering education to learners if similar performance outcomes were the evaluation criteria.

  20. In vitro comparison of an Er:YAG laser-activated bleaching system with different light-activated bleaching systems for color change, surface roughness, and enamel bond strength.

    PubMed

    Ergin, Esra; Ruya Yazici, A; Kalender, Bercem; Usumez, Aslihan; Ertan, Atilla; Gorucu, Jale; Sari, Tugrul

    2018-06-02

    To compare an Er:YAG laser-activated bleaching system with different light-activated in-office bleaching systems for color change, surface roughness, and post-bleaching enamel bond strength. 51 enamel slabs were prepared from the sound buccal enamel of extracted bovine teeth. The teeth were randomly divided into three groups according to different light-activated office bleaching systems (n = 17): diode laser (Epic, Biolase) (940 nm, 7 W, continuous mode), Er:YAG laser (LightWalker, Fotona) (2940 nm, 50 mJ, 10 Hz, 1000 μs), and LED (Radii Plus) (440-480 nm, 1500 mW/cm 2 ). All systems were used with their compatible bleaching agents according to manufacturers' recommendations. The tooth color and surface roughness (Ra) were assessed at baseline and after bleaching using a spectrophotometer and a surface profilometer, respectively. The color change was determined by the CIE L*a*b* system (ΔE, ΔL*, Δa*, Δb*). Kruskal-Wallis test was used for color change whereas Kruskal-Wallis and Wilcoxon tests were used to analyze the roughness data. For shear bond strength test (SBS), composite cylinders were bonded on bleached enamel samples 14 days after bleaching procedures and stored in water (37 °C). Specimens were then debonded with a universal testing machine at 1 mm/min and data were analyzed by using Kruskal-Wallis test. All the tested bleaching systems were effective on color change (ΔE > 3.3) and produced similar color change (p > 0.05). There were no significant differences among the Ra values of the groups neither at baseline nor after bleaching (p > 0.05). However, comparing the baseline and after bleaching Ra values, a significant increase was observed for all tested groups (p < 0.05). Significant differences were also found among all systems for SBS (p < 0.05). The highest values were obtained in Er:YAG group, whereas the LED group revealed the lowest values (p < 0.05). All tested bleaching systems were effective on tooth whitening, whereas they all led to an increase on surface roughness. Although the current Er:YAG laser-activated bleaching system did not differ from other tested bleaching systems according to color change and surface roughness, it appears to provide better results in terms of SBS.

  1. Automatic Condensation of Electronic Publications by Sentence Selection.

    ERIC Educational Resources Information Center

    Brandow, Ronald; And Others

    1995-01-01

    Describes a system that performs automatic summaries of news from a large commercial news service encompassing 41 different publications. This system was compared to a system that used only the lead sentences of the texts. Lead-based summaries significantly outperformed the sentence-selection summaries. (AEF)

  2. Comparing Aedes vigilax Eggshell Densities in Saltmarsh and Mangrove Systems with Implications for Management.

    PubMed

    Dale, Pat; Knight, Jon; Griffin, Lachlan

    2014-12-12

    Aedes vigilax (Skuse), a nuisance and disease vector, is prolific in intertidal wetlands in Australia. Aedine mosquitoes oviposit directly onto substrate. The eggshells are relatively stable spatially and temporally, providing an estimate of mosquito larval production. The aims of the research were to compare, at a general level, oviposition in mangroves and saltmarshes, and to compare oviposition between different habitats within mangroves and saltmarshes. The results indicated that there were no significant differences between production in mangrove and saltmarsh overall. However, within each system there were significant differences between habitat classes, with mangrove hummocks being the most productive. All classes, except for fringing mangrove forests, produced sufficient densities of eggshells (>0.05/cc) to warrant concern. While mosquito production in mangroves is known, the significantly higher production rates in the mangrove hummock habitats had not been demonstrated. This warrants improved management strategies that both specifically target these parts of mangrove systems and, secondly, addresses the longer-term potential for mangrove hummock habitats developing in the future; such as, in response to sea level rise and mangrove encroachment into saltmarsh. A strategy to increase tidal flushing within the systems would improve water quality and mitigate adverse impacts while providing a source reduction outcome.

  3. Coordinate alignment of combined measurement systems using a modified common points method

    NASA Astrophysics Data System (ADS)

    Zhao, G.; Zhang, P.; Xiao, W.

    2018-03-01

    The co-ordinate metrology has been extensively researched for its outstanding advantages in measurement range and accuracy. The alignment of different measurement systems is usually achieved by integrating local coordinates via common points before measurement. The alignment errors would accumulate and significantly reduce the global accuracy, thus need to be minimized. In this thesis, a modified common points method (MCPM) is proposed to combine different traceable system errors of the cooperating machines, and optimize the global accuracy by introducing mutual geometric constraints. The geometric constraints, obtained by measuring the common points in individual local coordinate systems, provide the possibility to reduce the local measuring uncertainty whereby enhance the global measuring certainty. A simulation system is developed in Matlab to analyze the feature of MCPM using the Monto-Carlo method. An exemplary setup is constructed to verify the feasibility and efficiency of the proposed method associated with laser tracker and indoor iGPS systems. Experimental results show that MCPM could significantly improve the alignment accuracy.

  4. Comparative evaluation of canal transportation, centering ability, and remaining dentin thickness between WaveOne and ProTaper rotary by using cone beam computed tomography: An in vitro study

    PubMed Central

    Jain, Aditi; Asrani, Hemant; Singhal, Abhinav Chand; Bhatia, Taranjeet Kaur; Sharma, Vaibhav; Jaiswal, Pragya

    2016-01-01

    Aims: To compare the canal transportation, centering ability, and remaining dentin thickness of WaveOne and ProTaper systems using cone beam computed tomography. Subjects and Methods: Forty extracted human single-rooted premolars were used in the present study. Preinstrumentation scanning of all teeth was taken; canal curvatures were calculated, and the samples were randomly divided into two groups, with twenty samples in each group; one group was instrumented with WaveOne system and the other group with ProTaper rotary system. Postinstrumentation scans were performed, and the two scans were compared to determine canal transportation, centering ability, and remaining dentin thickness at 3 mm, 6 mm, and 9 mm from the root apex. Statistical Analysis Used: Student's unpaired t-test. Results: Using Student's unpaired t-test, results were as follows: for canal transportation, Group 1 showed significant difference at 3 mm and 6 mm and insignificant difference at 9 mm while Group 2 showed insignificant difference in all the three regions. For centering ability and remaining dentin thickness, Group 1 showed insignificant difference at 3 mm and 9 mm while significant difference at 6 mm was obtained. When comparison of remaining dentin thickness was done at three levels using two groups WaveOne and ProTaper, there was no significant difference between two groups. Conclusions: (1) WaveOne single reciprocation file system respected better canal anatomy better than ProTaper. (2) Individually, centering ability of WaveOne was better at 3 mm, 6 mm, and 9 mm levels. (3) However, ProTaper individually was better centered at 3 mm (apical third) and 9 mm (coronal 3rd) levels than 6 mm level (middle third). PMID:27656063

  5. Effect of different polishing systems and drinks on the color stability of resin composite.

    PubMed

    Berber, Asll; Cakir, Filiz Yalcin; Baseren, Meserret; Gurgan, Sevil

    2013-07-01

    The purpose of this study was to evaluate the color stability of resin composit using different finishing systems and drinks. Composit disks (5 mm diameter, 2 mm thickness) were prepared for each nanofilled composite using a brass mold. The specimens were divided into 5 finishing system groups Mylar strip (Mylar, DuPont, Wilmington, Del., USA), Soft Lex (3M(™) ESPE(™) St. Paul, MN, USA), Enhance (Dentsply-DeTrey GmbHD Konstanz, Germany), Hiluster (KerrHawe, Bioggio, Switzerland), Opti Disc (KerrHawe, Bioggio, Switzerland) and each group was divided into 10 subgroups (n = 10) and stored for 24 hours at 37°C in different drinks water coffee, coffee with sugar, tea, tea with sugar, diet coke, coke, light sour cherry juice or sour cherry juice. Color of all specimens was measured before and after exposure with a spectrophotometer using CIE L*a*b* relative, and color changes (ΔE*) were then calculated. The data were analyzed with a twoway analysis of variance (ANOVA), and mean values were compared by the Tukey HSD test (p = 0.05). For the drinks, the lowest ΔE* values were observed in the water and highest ΔE* values were observed in sour cherry juice. When drinks with and without sugar were compared, all groups with sugar demonstrated a higher color difference than without sugar. For the different finishing systems, Mylar strip group demonstrated significantly highest color change; Enhance groups demonstrated significantly lowest color change. Finishing treatments and storage solutions significantly affect the color stability of resin composite. The presence of sugar in drinks increased the color difference compared to drinks without composit. Polishing techniques and drinking drinks with sugar may affect the color of esthetic restorations.

  6. Effects of acid etching and adhesive treatments on host-derived cysteine cathepsin activity in dentin.

    PubMed

    Zhang, Wenhao; Yang, Weixiang; Wu, Shuyi; Zheng, Kaibin; Liao, Weili; Chen, Boli; Yao, Ke; Liang, Guobin; Li, Yan

    2014-10-01

    To analyze the effects of different processes during bonding on endogenous cysteine cathepsin activity in dentin. Dentin powder, prepared from extracted human third molars, was divided into 10 groups. Two lots of dentin powder were used to detect the effects of the procedure of protein extraction on endogenous cathepsin activity. The others were used to study effects of different acid-etching or adhesive treatments on enzyme activity. Concentrations of 37% phosphoric acid or 10% phosphoric acid, two etch-and-rinse adhesive systems, and two self-etching adhesive systems were used as dentin powder treatments. The untreated mineralized dentin powder was set as the control. After treatment, the proteins of each group were extracted. The total cathepsin activity in the extracts of each group was monitored with a fluorescence reader. In the control group, there were no significant differences in cathepsin activity between the protein extract before EDTA treatment and the protein extract after EDTA treatment (p > 0.05). The cathepsin activities of the three different extracts in the 37% phosphoric acid-treated group were different from each other (p < 0.05). The two acid-etching groups and two etch-and-rinse groups showed significant enzyme activity reduction vs the control group (p < 0.05). There were no significant differences between those four groups (p > 0.05). Treating the dentin powder with any of the two self-etching adhesives resulted in an increase in cathepsin activity (p < 0.05). The activity of cysteine cathepsins can be detected in dentin powder. Treatment with EDTA during protein extraction exerted an influence on cathepsin activity. Acid etching or etch-and-rinse adhesive systems may reduce the activity of endogenous cathepsins in dentin. Self-etching adhesive systems may increase the enzyme activity.

  7. Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart.

    PubMed

    Wang, Yu; Cao, Hai-yan; Xie, Ming-xing; He, Lin; Han, Wei; Hong, Liu; Peng, Yuan; Hu, Yun-fei; Song, Ben-cai; Wang, Jing; Wang, Bin; Deng, Cheng

    2016-04-01

    To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.

  8. The ILLIAC IV memory system: Current status and future possibilities

    NASA Technical Reports Server (NTRS)

    Stevenson, D. K.

    1978-01-01

    The future needs of researchers who will use the Illiac were examined and the requirements they will place on the memory system were evaluated. Various alternatives to replacing critical memory components were considered with regard to cost, risk, system impact, software requirements, and implementation schedules. The current system, its performance and status, and the limitations it places on possible enhancements are discussed as well as the planned enhancements to the Illiac processor. After a brief technology survey, different implementations are presented for each system memory component. Three different memory systems are proposed to meet the identified needs of the Illiac user community. These three alternatives differ considerably with respect to storage capacity and accessing capabilities, but they all offer significant improvements over the current system. The proposed systems and their relative merits are analyzed.

  9. Modulating the Release Kinetics of Paclitaxel from Membrane-Covered Stents Using Different Loading Strategies

    PubMed Central

    Sydow-Plum, Georg; Haidar, Ziyad S.; Merhi, Yahye; Tabrizian, Maryam

    2008-01-01

    Membrane-covered Express2TM Monorail® stents composed of chitosan (CH) blended with polyethylene oxide (PEO) in 70:30% wt (CH-PEO) were coated with a monolayer of hyaluronic acid (HA). This significantly improved the resistance to platelet adhesion and demonstrated excellent mechanical properties, resisting the harsh conditions during stent crimping and subsequent inflation. CH-PEO/HA membrane was then combined with a paclitaxel (Pac) delivery system via three different approaches for comparison of release profiles of Pac. The activity of Pac in these systems was confirmed since its presence in the membrane significantly decreased cell viability of U937 macrophages. Presented results are promising for applications requiring different release patterns of hydrophobic drugs.

  10. Sports injuries in women: sex- and gender-based differences in etiology and prevention.

    PubMed

    Templeton, Kimberly J; Hame, Sharon L; Hannafin, Jo A; Griffin, Letha Y; Tosi, Laura L; Shields, Naomi N

    2008-01-01

    There has been a significant increase in the participation of women in sports at all levels, especially after the enactment of the Title IX Education Amendment in 1972. This increased participation at all levels has resulted in more women sustaining sports injuries. Data on sex- and gender-based differences in all organ systems, including the musculoskeletal system, are beign gathered. It is important to review some of the areas of sex- and gender-based differences in sports injuries for which there is significant research, such as osteoporosis, the female athlete triad, and anterior cruciate ligament injuries. It is also necessary to examine those areas in which more information is needed, such as injuries to the shoulder, foot, and ankle.

  11. Reduction effect of bacterial counts by preoperative saline lavage of the stomach in performing laparoscopic and endoscopic cooperative surgery.

    PubMed

    Mori, Hirohito; Kobara, Hideki; Tsushimi, Takaaki; Fujihara, Shintaro; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Tani, Joji; Miyoshi, Hisaaki; Morishita, Asahiro; Masaki, Tsutomu

    2014-11-14

    To investigate the effects of gastric lavage with 2000 mL of saline in laparoscopic and endoscopic cooperative surgery. Twenty two patients who were diagnosed with a gastric gastrointestinal stromal tumor were enrolled. In former term, irrigations of the stomach were conducted whenever it was necessary, not systematically (Non systemic lavage group). In latter term, the stomach was thoroughly cleaned with 2000 mL of saline using an endoscope with a water jet, and Duodenal balloon occlusion was conducted to prevent refluxed bile and pancreatic juice (Systemic lavage+balloon occlusion group). The gastric wall was sprayed with 20 mL of distilled water, and 20 mL of gastric juice was collected in a sterile tube and submitted for culture. 20 mL of ascites was also collected from the laparoscopic ports and submitted for culture. We compared WBC, CRP, BT between two groups, and verify the reduction effect of bacterial counts in Systemic lavage+balloon occlusion group. WBC count before, 1 d after, and 3 d after laparoscopic and endoscopic cooperative surgery (LECS) were 5060 (95%CI: 4250-9640), 12140 (6050-14110), and 6910 (5320-12520) in Non systemic lavage group, 4400 (3660-7620), 8910 (6480-10980), and 5950 (4840-7860) in Systemic lavage+balloon occlusion group. Significant differences between two groups at the day after LECS (P = 0.029) and the 3 d after LECS (P = 0.042). CRP levels in Non systemic lavage group and in Systemic lavage+balloon occlusion group were significantly different at the day after LECS (P = 0.005) and the 3 d after LECS (P = 0.028). BTs (°C) in Non systemic lavage group and in Systemic lavage+balloon occlusion group were also significantly different at the day after LECS (P = 0.004) and the 3 d after LECS (P = 0.006). In a logarithmic comparison, bacterial load before gastric lavage, after lavage, and ascites culture were 6.08 (95%CI: 4.04-6.97), 0.48 (0-0.85), and 0.21 (0-0.56). The bacterial counts before and after gastric lavage were significantly suppressed (P = 0.007), but no significant difference between gastric juice culture after lavage and ascites (P = 0.154). Pre-LECS lavage with 2000 mL of saline exhibited a bacteria-reducing effect equivalent to disinfectants and obtained favorable results in terms of clinical symptoms and data.

  12. Ruggedness/robustness evaluation and system suitability test on United States Pharmacopoeia XXVI assay ginsenosides in Asian and American ginseng by high-performance liquid chromatography.

    PubMed

    Li, Yong-Guo; Chen, Ming; Chou, Gui-Xin; Wang, Zheng-Tao; Hu, Zhi-Bi

    2004-09-03

    The work of the ruggedness/robustness evaluation and system suitability tests was oriented to profound understand the practicability of using assay methods issued by United States Pharmacopoeia (USP XXVI and XXVII) for ginsenosides in Asian ginseng and American ginseng. The items chosen for the method validation included quantitative related items such as recovery of Rg(1) and Rb(1), respectively, and qualitative related items such as resolution, theoretical plate number, relative retention time of two critical-band-pairs, Rg(1)/Re and Rb(1) with its neighboring peak, respectively. Totally, 16 column types were used for comparison of different vendors, different packing materials, different size, etc. and five sets of LC systems and two laboratories were involved in comparing the data of both quantitative and qualitative items. The results showed that different packing materials of columns used might significantly alters separation. The column packing material Hypersil afforded the preferable separating for the ginsenosides. No significant difference was observed from the different instrumentations and inter-laboratories. Our results suggest a modification of the system suitability test as given in USP26-NF21 and the latest version of USP27-NF22, which was not suitable for most systems. Using resolutions of Rg(1)/Re and Rb(1) with its neighboring peak as critical parameters for the ginsenosides assay and omitting the relative retention time of both Rg(1)/Re and Rb(1) with its neighboring peak is our suggestion for a more reasonable, yet practicable system suitability. Six typical chromatograms gain from different columns were figured out as well.

  13. Regional differences in endothelial cell cytoskeleton, junctional proteins and phosphorylated tyrosine labeling in the porcine vortex vein system.

    PubMed

    Tan, Priscilla Ern Zhi; Yu, Paula K; Yang, Hongfang; Cringle, Stephen J; Yu, Dao-Yi

    2018-07-01

    We previously demonstrated endothelial phenotype heterogeneity in the vortex vein system. This study is to further determine whether regional differences are present in the cytoskeleton, junctional proteins and phosphorylated tyrosine labeling within the system. The vortex vein system of twenty porcine eyes was perfused with labels for f-actin, claudin-5, VE-Cadherin, phosphorylated tyrosine and nucleic acid. The endothelial cells of eight different regions (choroidal veins, pre-ampulla, anterior ampulla, mid-ampulla, posterior ampulla, post-ampulla, intra-scleral canal and the extra-ocular vortex vein) were studied using confocal microscopy. There were regional differences in the endothelial cell structures. Cytoskeleton labeling was relatively even in intensity throughout Regions 1 to 6. Overall VE-Cadherin had a non-uniform distribution and thicker width endothelial cell border staining than claudin-5. Progressing downstream there was an increased variation in thickness of VE-cadherin labeling. There was an overlap in phosphorylated tyrosine and VE-Cadherin labeling in the post-ampulla, intra-scleral canal and extra-ocular vortex vein. Intramural cells were observed that were immune-positive for VE-Cadherin and phosphorylated tyrosine. There were significant differences in the number of intramural cells in different regions. Significant regional differences with endothelial cell labeling of cytoskeleton, junction proteins, and phosphorylated tyrosine were found within the vortex vein system. These findings support existing data on endothelial cell phenotype heterogeneity, and may aid in the knowledge of venous pathologies by understanding regions of vulnerability to endothelial damage within the vortex vein system. It could be valuable to further investigate and characterize the VE-cadherin and phosphotyrosine immune-positive intramural cells. Copyright © 2018. Published by Elsevier Ltd.

  14. Differences between Subjective Balanced Occlusion and Measurements Reported With T-Scan III

    PubMed Central

    Lila-Krasniqi, Zana; Shala, Kujtim; Krasniqi, Teuta Pustina; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda; Dragusha, Arlinda Tmava; Guguvcevski, Ljuben

    2017-01-01

    BACKGROUND: The aetiology of Temporomandibular disorder is multifactorial, and numerous studies have addressed that occlusion may be of great importance in the pathogenesis of Temporomandibular disorder. AIM: The aim of this study is to determine if any direct relationship exists between balanced occlusion and Temporomandibular disorder and to evaluate the differences between subjective balanced occlusion and measurements reported with T-scan III electronic system. MATERIAL AND METHODS: A total of 54 subjects were divided into three groups, selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analysed with electronic system T-scan III. In the I study group were participants with fixed dentures with prosthetic ceramic restorations. In the II study group were symptomatic participants with TMD. In the third control group were healthy participants with full arch dentition that completed a subjective questionnaire that documented the absence of jaw pain, joint noise, locking and subjects without a history of TMD. The occlusal balance was reported subjectively through Fonseca questionnaire and compared with occlusion analysed with electronic system T-scan III. RESULTS: For attributive data were used percentage of the structure. Differences in P < 0.05 were considered significant. After distributing attributive data of occlusal balance subjectively reported and compared with measurements analysed with electronic system T-scan III were found significant difference P < 0.001 in all three groups. CONCLUSION: In our study, it was concluded that there were statistically significant differences of balanced occlusion in all three groups. Also it was concluded that subjective data are not exact with measurements reported with electronic device T-scan III. PMID:28932311

  15. [Comparison of paired box genes 8 and 2 expression in epithelium tissues and the related tumors].

    PubMed

    Song, Y; Huang, X; Shen, G H; Liu, X Y; Zhang, X

    2017-06-23

    Objective: To explore the expressional differences between paired box genes 2(Pax2) and 8 (Pax8) protein in different kinds of epitheliums and tumors, and to investigate the clinicopathologic significance. Methods: Expression levels of Pax2 and Pax8 protein were detected in 75 cases of different human epithelium tissues and 255 cases of different tumors on tissue microarray by immunohistochemistry. Results: Pax2 and Pax8 selectively expressed in different tissues. The positive rates of Pax8 protein expressed in the normal epithelium of the thyroid, urinary system and female reproductive system were 100% (2/2), 60.0% (3/5) and 76.9% (10/13), respectively. The positive rates of Pax2 expressed in the epithelium tissues of urinary system and the female reproductive system were 40.0% (2/5) and 38.5% (5/13) respectively. However, the expression of Pax2 protein was not detected in the normal thyroid epithelium. The positive rate of Pax8 protein expressing in the epithelium of reproductive system was significantly higher than that of Pax2 protein ( P <0.05). The tumors derived from different tissues also expressed different levels of protein Pax2 and Pax8. The positive rates of Pax8 in renal cell carcinoma, thyroid carcinoma and endometrial adenocarcinoma were 65.2% (15/23), 66.7% (10/15) and 80.0% (4/5), respectively. The positive rates of Pax2 in renal cell carcinoma, thyroid carcinoma and endometrial adenocarcinoma were 34.8% (8/23), 13.3% (2/15) and 20.0% (1/5), respectively. The positive rates of Pax8 protein expressed in renal cell carcinoma, thyroid carcinoma and endometrial adenocarcinoma were significantly higher than those of Pax2 protein ( P <0.05). The positive rates of Pax8 in ovarian serous carcinoma, endometrial carcinoma and clear cell carcinoma were 92.9% (26/28), 81.8% (9/11) and 82.4% (14/17), respectively. The positive rates of Pax2 in ovarian serous carcinoma, endometrial carcinoma and clear cell carcinoma were 28.6% (8/28), 9.1% (1/11) and 17.6% (3/17), respectively. The positive rates of Pax8 protein expressed in ovarian serous carcinoma, endometrial carcinoma and clear cell carcinomawere significantly higher than those of Pax2 protein ( P <0.05). Conclusions: Pax2 and Pax8 are specifically expressed in female reproductive system and uritany system. However, the positive expression of Pax8 is superior to that of Pax2. The combined expression of Pax8 and Pax2 can be used in the differential diagnosis of epithelial tumors derived from different origins.

  16. The earnings and employment losses before entering the disability system.

    PubMed

    Cervini-Pla, Maria; Vall Castelló, Judit

    2018-02-17

    Although a number of papers in the literature have shown the employment and wage differences between individuals receiving disability benefits and non-disabled individuals, not much is known about the potential employment and wage losses that disabled individuals suffer before being officially accepted into the disability insurance system (DI). Therefore, in this paper we compare individuals that enter into the DI system due to a progressive deterioration in the health status (ordinary illness) to similar non-disabled individuals. Our aim is to identify the differences in employment and wages between these two groups before disabled individuals are officially accepted into the DI system. We combine matching models and difference-in-difference and we find that the wage (employment) growth patterns of both groups of workers become significantly different three (five) years before entering the DI system. More specifically, our estimates suggest that 1 year before entering the system, there is a difference of 79 Euros/month in the wages of the two groups (8.3% of average wage) as well as a 7.8% point difference in employment probabilities.

  17. Microbial community and removal of nitrogen via the addition of a carrier in a pilot-scale duckweed-based wastewater treatment system.

    PubMed

    Zhao, Yonggui; Fang, Yang; Jin, Yanling; Huang, Jun; Ma, Xinrong; He, Kaize; He, Zhiming; Wang, Feng; Zhao, Hai

    2015-03-01

    Carriers were added to a pilot-scale duckweed-based (Lemna japonica 0223) wastewater treatment system to immobilize and enhance microorganisms. This system and another parallel duckweed system without carriers were operated for 1.5 years. The results indicated the addition of the carrier did not significantly affect the growth and composition of duckweed, the recovery of total nitrogen (TN), total phosphorus (TP) and CO2 or the removal of TP. However, it significantly improved the removal efficiency of TN and NH4(+)-N (by 19.97% and 15.02%, respectively). The use of 454 pyrosequencing revealed large differences of the microbial communities between the different components within a system and similarities within the same components between the two systems. The carrier biofilm had the highest bacterial diversity and relative abundance of nitrifying bacteria (3%) and denitrifying bacteria (24% of Rhodocyclaceae), which improved nitrogen removal of the system. An efficient N-removal duckweed system with enhanced microorganisms was established. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Performance of Radiant Heating Systems of Low-Energy Buildings

    NASA Astrophysics Data System (ADS)

    Sarbu, Ioan; Mirza, Matei; Crasmareanu, Emanuel

    2017-10-01

    After the introduction of plastic piping, the application of water-based radiant heating with pipes embedded in room surfaces (i.e., floors, walls, and ceilings), has significantly increased worldwide. Additionally, interest and growth in radiant heating and cooling systems have increased in recent years because they have been demonstrated to be energy efficient in comparison to all-air distribution systems. This paper briefly describes the heat distribution systems in buildings, focusing on the radiant panels (floor, wall, ceiling, and floor-ceiling). Main objective of this study is the performance investigation of different types of low-temperature heating systems with different methods. Additionally, a comparative analysis of the energy, environmental, and economic performances of floor, wall, ceiling, and floor-ceiling heating using numerical simulation with Transient Systems Simulation (TRNSYS) software is performed. This study showed that the floor-ceiling heating system has the best performance in terms of the lowest energy consumption, operation cost, CO2 emission, and the nominal boiler power. The comparison of the room operative air temperatures and the set-point operative air temperature indicates also that all radiant panel systems provide satisfactory results without significant deviations.

  19. Enamel Wetness Effects on Microshear Bond Strength of Different Bonding Agents (Adhesive Systems): An in vitro Comparative Evaluation Study.

    PubMed

    Kulkarni, Girish; Mishra, Vinay K

    2016-05-01

    The purpose of this study was to compare the effect of enamel wetness on microshear bond strength using different adhesive systems. To evaluate microshear bond strength of three bonding agents on dry enamel; to evaluate microshear bond strength of three bonding agents on wet enamel; and to compare microshear bond strength of three different bonding agents on dry and wet enamel. Sixty extracted noncarious human premolars were selected for this study. Flat enamel surfaces of approximately 3 mm were obtained by grinding the buccal surfaces of premolars with water-cooled diamond disks. This study evaluated one etch-and-rinse adhesive system (Single Bond 2) and two self-etching adhesive systems (Clearfil SE Bond and Xeno-V). The specimens were divided into two groups (n = 30). Group I (dry) was air-dried for 30 seconds and in group II (wet) surfaces were blotted with absorbent paper to remove excess water. These groups were further divided into six subgroups (n = 10) according to the adhesives used. The resin composite, Filtek Z 250, was bonded to flat enamel surfaces that had been treated with one of the adhesives, following the manufacturer's instructions. After being stored in water at 37°C for 24 hours, bonded specimens were stressed in universal testing machine (Fig. 3) at a crosshead speed of 1 mm/min. The data were evaluated with one-way and two-way analysis of variance (ANOVA), t-test, and Tukey's Multiple Post hoc tests (a = 0.05). The two-way ANOVA and Tukey's Multiple Post hoc tests showed significant differences among adhesive systems, but wetness did not influence microshear bond strength (p = 0.1762). The one-way ANOVA and t-test showed that the all-in-one adhesive (Xeno-V) was the only material influenced by the presence of water on the enamel surface. Xeno-V showed significantly higher microshear bond strength when the enamel was kept wet. Single Bond 2 adhesive showed significantly higher microshear bond strength as compared with Xeno-V adhesive but no significant difference when compared with Clearfil SE Bond adhesive in dry enamel. Single Bond 2 adhesive showed no significant difference in microshear bond strength as compared with self-etching adhesive systems (Clearfil SE Bond and Xeno-V), when the enamel was kept wet. From the findings of the results, it was concluded that self-etching adhesives were not negatively affected by the presence of water on the enamel surface. The all-in-one adhesive showed different behavior depending on whether the enamel surface was dry or wet. So the enamel surface should not be desiccated, when self-etching adhesives are used.

  20. Effect of culturing conditions on the expression of key enzymes in the proteolytic system of Lactobacillus bulgaricus *

    PubMed Central

    Hou, Jun-cai; Liu, Fei; Ren, Da-xi; Han, Wei-wei; Du, Yue-ou

    2015-01-01

    The proteolytic system of Lactobacillus bulgaricus breaks down milk proteins into peptides and amino acids, which are essential for the growth of the bacteria. The aim of this study was to determine the expressions of seven key genes in the proteolytic system under different culturing conditions (different phases, initial pH values, temperatures, and nitrogen sources) using real-time polymerase chain reaction (RT-PCR). The transcriptions of the seven genes were reduced by 30-fold on average in the stationary phase compared with the exponential growth phase. The transcriptions of the seven genes were reduced by 62.5-, 15.0-, and 59.0-fold in the strains KLDS 08006, KLDS 08007, and KLDS 08012, respectively, indicating that the expressions of the seven genes were significantly different among strains. In addition, the expressions of the seven genes were repressed in the MRS medium containing casein peptone. The effect of peptone supply on PepX transcription was the weakest compared with the other six genes, and the impact on OppD transcription was the strongest. Moreover, the expressions of the seven genes were significantly different among different strains (P<0.05). All these results indicated that the culturing conditions affected the expression of the proteolytic system genes in Lactobacillus bulgaricus at the transcription level. PMID:25845365

  1. Effects of acute hypoxia on heart rate variability, sample entropy and cardiorespiratory phase synchronization.

    PubMed

    Zhang, Da; She, Jin; Zhang, Zhengbo; Yu, Mengsun

    2014-06-11

    Investigating the responses of autonomic nervous system (ANS) in hypoxia may provide some knowledge about the mechanism of neural control and rhythmic adjustment. The integrated cardiac and respiratory system display complicated dynamics that are affected by intrinsic feedback mechanisms controlling their interaction. To probe how the cardiac and respiratory system adjust their rhythms in different simulated altitudes, we studied heart rate variability (HRV) in frequency domain, the complexity of heartbeat series and cardiorespiratory phase synchronization (CRPS) between heartbeat intervals and respiratory cycles. In this study, twelve male subjects were exposed to simulated altitude of sea level, 3000 m and 4000 m in a hypobaric chamber. HRV was assessed by power spectral analysis. The complexity of heartbeat series was quantified by sample entropy (SampEn). CRPS was determined by cardiorespiratory synchrogram. The power spectral HRV indices at all frequency bands depressed according to the increase of altitude. The SampEn of heartbeat series increased significantly with the altitude (P < 0.01). The duration of CRPS epochs at 3000 m was not significantly different from that at sea level. However, it was significantly longer at 4000 m (P < 0.01). Our results suggest the phenomenon of CRPS exists in normal subjects when they expose to acute hypoxia. Further, the autonomic regulation has a significantly stronger influence on CRPS in acute hypoxia. The changes of CRPS and HRV parameters revealed the different regulatory mechanisms of the cardiac and respiratory system at high altitude.

  2. In vitro marginal fit of three all-ceramic crown systems.

    PubMed

    Yeo, In-Sung; Yang, Jae-Ho; Lee, Jai-Bong

    2003-11-01

    Studies on marginal discrepancies of single restorations using various systems and materials have resulted in statistical inferences that are ambiguous because of small sample sizes and limited numbers of measurements per specimen. The purpose of this study was to compare the marginal adaptation of single anterior restorations made using different systems. The in vitro marginal discrepancies of 3 different all-ceramic crown systems (Celay In-Ceram, conventional In-Ceram, and IPS Empress 2 layering technique), and a control group of metal ceramic restorations were evaluated and compared by measuring the gap dimension between the crowns and the prepared tooth at the marginal opening. The crowns were made for 1 extracted maxillary central incisor prepared with a 1-mm shoulder margin and 6-degree tapered walls by milling. Thirty crowns per system were fabricated. Crown measurements were recorded with an optical microscope, with an accuracy of +/-0.1 microm, at 50 points spaced approximately 400 microm along the circumferential margin. The criterion of 120 microm was used as the maximum clinically acceptable marginal gap. Mean gap dimensions and standard deviations were calculated for marginal opening. The data were analyzed with a 1-way analysis of variance (alpha=.05). Mean gap dimensions and standard deviations at the marginal opening for the incisor crowns were 87 +/- 34 microm for control, 83 +/- 33 microm for Celay In-Ceram, 112 +/- 55 microm for conventional In-Ceram, and 46 +/- 16 microm for the IPS Empress 2 layering technique. Significant differences were found among the crown groups (P<.05). Compared with the control group, the IPS Empress 2 group had significantly smaller marginal discrepancies (P<.05), and the conventional In-Ceram group exhibited significantly greater marginal discrepancies (P<.05). There was no significant difference between the Celay In-Ceram and the control group. Within the limitations of this study, the marginal discrepancies were all within the clinically acceptable standard set at 120 microm. However, the IPS Empress 2 system showed the smallest and most homogeneous gap dimension, whereas the conventional In-Ceram system presented the largest and more variable gap dimension compared with the metal ceramic (control) restoration.

  3. Analysis of vertical marginal discrepancy in feldspathic porcelain crowns manufactured with different CAD/CAM systems: Closed and open.

    PubMed

    Kricheldorf, Fabio; Bueno, Cleuber Rodrigo de Souza; Amaral, Wilson da Silva; Junior, Joel Ferreira Santiago; Filho, Hugo Nary

    2018-01-01

    The objective of this study is to compare the marginal adaptation of feldspathic porcelain crowns using two computer-aided design/computer-aided manufacturing systems, one of them is open and the other is closed. Twenty identical titanium abutments were divided into two groups: open system (OS), where ceramic crowns were created using varied equipment and software, and closed system (CS), where ceramic crowns were created using the CEREC system. Through optical microscopy analysis, we assess the marginal adaptation of the prosthetic interfaces. The data were subjected to the distribution of normality and variance. The t -test was used for the analysis of the comparison factor between the groups, and the one-way ANOVA was used to compare the variance of crown analysis regions within the group. A significance level of 5% was considered for the analyses. There was a significant difference between the systems ( P = 0.007), with the CS group having the higher mean (23.75 μm ± 3.05) of marginal discrepancy when compared to the open group (17.94 μm ± 4.77). Furthermore, there were no differences in marginal discrepancy between the different points between the groups ( P ≥ 0.05). The studied groups presented results within the requirements set out in the literature. However, the OS used presented better results in marginal adaptation.

  4. [Evaluation of the appropriateness of hospital admissions using the iso-gravity classification systems APR-DRG and Disease Staging and the Italian version of Appropriateness Evaluation Protocol (AEP)].

    PubMed

    D'Andrea, G; Capalbo, G; Volpe, M; Marchetti, M; Vicentini, F; Capelli, G; Cambieri, A; Cicchetti, A; Ricciardi, G; Catananti, C

    2006-01-01

    Our main purpose was to evaluate the organizational appropriateness of admissions made in a university hospital, by comparing two iso-gravity classification systems, APR-DRG and Disease Staging, with the Italian version of AEP (PRUO). Our analysis focused on admissions made in 2001, related to specific Diagnosis Related Groups (DRGs), which, according an Italian Law, would be considered at high risk of inappropriateness, if treated as ordinary admissions. The results obtained by using the 2 classification systems did not show statistically significant differences with respect to the total number of admissions. On the other hand, some DRGs showed statistically significant differences due to different algorithms of attribution of the severity levels used by the two systems. For almost all of the DRGs studied, the AEP-based analysis of a sample of medical records showed an higher number of inappropriate admissions in comparison with the number expected by iso-gravity classification methods. The difference is possibly due to the percentage limits of tolerability fixed by the Law for each DRG. Therefore, the authors suggest an integrated use of the two methods to evaluate organizational appropriateness of hospital admissions.

  5. Do Online Information Retrieval Systems Help Experienced Clinicians Answer Clinical Questions?

    PubMed Central

    Westbrook, Johanna I.; Coiera, Enrico W.; Gosling, A. Sophie

    2005-01-01

    Objective: To assess the impact of clinicians' use of an online information retrieval system on their performance in answering clinical questions. Design: Pre-/post-intervention experimental design. Measurements: In a computer laboratory, 75 clinicians (26 hospital-based doctors, 18 family practitioners, and 31 clinical nurse consultants) provided 600 answers to eight clinical scenarios before and after the use of an online information retrieval system. We examined the proportion of correct answers pre- and post-intervention, direction of change in answers, and differences between professional groups. Results: System use resulted in a 21% improvement in clinicians' answers, from 29% (95% confidence interval [CI] 25.4–32.6) correct pre- to 50% (95% CI 46.0–54.0) post-system use. In 33% (95% CI 29.1–36.9) answers were changed from incorrect to correct. In 21% (95% CI 17.1–23.9) correct pre-test answers were supported by evidence found using the system, and in 7% (95% CI 4.9–9.1) correct pre-test answers were changed incorrectly. For 40% (35.4–43.6) of scenarios, incorrect pre-test answers were not rectified following system use. Despite significant differences in professional groups' pre-test scores [family practitioners: 41% (95% CI 33.0–49.0), hospital doctors: 35% (95% CI 28.5–41.2), and clinical nurse consultants: 17% (95% CI 12.3–21.7; χ2 = 29.0, df = 2, p < 0.01)], there was no difference in post-test scores. (χ2 = 2.6, df = 2, p = 0.73). Conclusions: The use of an online information retrieval system was associated with a significant improvement in the quality of answers provided by clinicians to typical clinical problems. In a small proportion of cases, use of the system produced errors. While there was variation in the performance of clinical groups when answering questions unaided, performance did not differ significantly following system use. Online information retrieval systems can be an effective tool in improving the accuracy of clinicians' answers to clinical questions. PMID:15684126

  6. A new coordinate system for rodent brain and variability in the brain weights and dimensions of different ages in the naked mole-rat.

    PubMed

    Xiao, Jun

    2007-05-15

    Traditionally, the skull landmarks, i.e., bregma, lambda, and the interaural line, are the origins of the coordinate system for almost all rodent brain atlases. The disadvantages of using a skull landmark as an origin are: (i) there are differences among individuals in the alignment between the skull and the brain; (ii) the shapes of sutures, on which a skull landmark is determined, are different for different animals; (iii) the skull landmark is not clear for some animals. Recently, the extreme point of the entire brain (the tip of the olfactory bulb) has also been used as the origin for an atlas coordinate system. The accuracy of stereotaxically locating a brain structure depends on the relative distance between the structure and the reference point of the coordinate. The disadvantages of using the brain extreme as an origin are that it is located far from most brain structures and is not readily exposed during most in vivo procedures. To overcome these disadvantages, this paper introduces a new coordinate system for the brain of the naked mole-rat. The origin of this new coordinate system is a landmark directly on the brain: the intersection point of the posterior edges of the two cerebral hemispheres. This new coordinate system is readily applicable to other rodent species and is statistically better than using bragma and lambda as reference points. It is found that the body weight of old naked mole-rats is significantly bigger than that of young animals. However, the old naked mole-rat brain is not significantly heavier than that of young animal. Both brain weight and brain length vary little among animals of different weights. The disadvantages of current definition of "significant" are briefly discussed and a new expression that describes more objectively the result of statistical test is brought up and used.

  7. Effects of Different Lifting Cadences on Ground Reaction Forces during the Squat Exercise

    NASA Technical Reports Server (NTRS)

    Bentley, Jason R.; Amonette, William E.; Hagan, R. Donald

    2008-01-01

    The purpose of this investigation was to determine the effect of different cadences on the ground reaction force (GRF(sub R)) during the squat exercise. It is known that squats performed with greater acceleration will produce greater inertial forces; however, it is not well understood how different squat cadences affect GRF(sub R). It was hypothesized that faster squat cadences will result in greater peak GRF(sub R). METHODS: Six male subjects (30.8+/-4.4 y, 179.5+/-8.9 cm, 88.8+/-13.3 kg) with previous squat experience performed three sets of three squats using three different cadences (FC = 1 sec descent/1 sec ascent; MC = 3 sec descent/1 sec ascent; SC = 4 sec descent/2 sec ascent) with barbell mass equal to body mass. Ground reaction force was used to calculate inertial force trajectories of the body plus barbell (FI(sub system)). Forces were normalized to body mass. RESULTS: Peak GRF(sub R) and peak FI(sub system) were significantly higher in FC squats compared to MC (p=0.0002) and SC (p=0.0002). Range of GRF(sub R) and FI(sub system) were also significantly higher in FC compared to MC (p<0.05), and MC were significantly higher than SC (p<0.05). DISCUSSION: Faster squat cadences result in significantly greater peak GRF(sub R) due to the inertia of the system. GRF(sub R) was more dependent upon decent cadence than on ascent cadence. PRACTICAL APPLICATION: This study demonstrates that faster squat cadences produce greater ground reaction forces. Therefore, the use of faster squat cadences might enhance strength and power adaptations to long-term resistance exercise training. Key Words: velocity, weight training, resistive exercise

  8. Comparison between sequentional treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism.

    PubMed

    Nilforoushzadeh, Mohammad Ali; Naieni, Farahnaz Fatemi; Siadat, Amir Hossein; Rad, Leila

    2011-11-01

    Laser systems that are commonly used for the treatment of hirsutism include the ruby laser (694 nm), the diode laser (800 nm), the alexandrite laser (755 nm) and the Nd:YAG laser (1084 nm). The diode laser and alexandrite laser are considered effective in treatment of hirsutism in dark-skinned patients. The response of hairs to these laser systems is variable and not complete. In this study, we compared the efficacy of these two laser systems for permanent hair removal. This was a randomized, controlled clinical trial that was performed with women of the age range 15-45 years old. After obtaining informed consent, the samples were randomized into two groups using random allocation software. The first group was treated with alexandrite laser alone (four sessions, two months apart). The second group was treated sequentially with diode laser for the first two sessions and alexandrite laser for the next two sessions. Overall, 111 patients (57 patients in the alexandrite laser group and 54 patients in the sequential diode-alexandrite laser group) were evaluated. There was no significant difference regarding mean of hair reduction between the two groups during the courses of treatment. Except for the first session, there was no significant difference regarding percent of patient satisfaction between the two groups (P value >0.05). Comparison between the two groups showed no significant difference one month, three months and six months after the last treatment (P value >0.05). Regarding the results of our study, there is no significant difference between sequential treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism. We suggest that in further studies, the efficacy of sequential treatment with other laser systems is evaluated against single treatment methods.

  9. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study.

    PubMed

    Agarwal, Rolly S; Agarwal, Jatin; Jain, Pradeep; Chandra, Anil

    2015-05-01

    The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.

  10. 64 slice MDCT generally underestimates coronary calcium scores as compared to EBT: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greuter, M. J. W.; Dijkstra, H.; Groen, J. M.

    The objective of our study was the determination of the influence of the sequential and spiral acquisition modes on the concordance and deviation of the calcium score on 64-slice multi-detector computed tomography (MDCT) scanners in comparison to electron beam tomography (EBT) as the gold standard. Our methods and materials were an anthropomorphic cardio CT phantom with different calcium inserts scanned in sequential and spiral acquisition modes on three identical 64-slice MDCT scanners of manufacturer A and on three identical 64-slice MDCT scanners of manufacturer B and on an EBT system. Every scan was repeated 30 times with and 15 timesmore » without a small random variation in the phantom position for both sequential and spiral modes. Significant differences were observed between EBT and 64-slice MDCT data for all inserts, both acquisition modes, and both manufacturers of MDCT systems. High regression coefficients (0.90-0.98) were found between the EBT and 64-slice MDCT data for both scoring methods and both systems with high correlation coefficients (R{sup 2}>0.94). System A showed more significant differences between spiral and sequential mode than system B. Almost no differences were observed in scanners of the same manufacturer for the Agatston score and no differences for the Volume score. The deviations of the Agatston and Volume scores showed regression dependencies approximately equal to the square root of the absolute score. The Agatston and Volume scores obtained with 64-slice MDCT imaging are highly correlated with EBT-obtained scores but are significantly underestimated (-10% to -2%) for both sequential and spiral acquisition modes. System B is more independent of acquisition mode to calcium score than system A. The Volume score shows no intramanufacturer dependency and its use is advocated versus the Agatston score. Using the same cut points for MDCT-based calcium scores as for EBT-based calcium scores can result in classifying individuals into a too low risk category. System information and scanprotocol is therefore needed for every calcium score procedure to ensure a correct clinical interpretation of the obtained calcium score results.« less

  11. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    PubMed

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: <45, ~70, and ≥150 mmHg. For each system, five consecutive measurements on each sample aliquot were performed using the same test strip lot. Relative differences between the mean BG results at pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 <45 and ≥150 mmHg were calculated. For all tested GOx systems, mean relative differences in the BG measurement results were between 6.1% and 22.6% at pO2 <45 mmHg and between -7.9% and -14.9% at pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p < .0001). The GDH system showed mean relative differences of -1.0% and -0.4% at pO2 values <45 and ≥150 mmHg, respectively, which were not significant. These data suggest that capillary blood pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. © 2013 Diabetes Technology Society.

  12. Comparison of the compressive strength of 3 different implant design systems.

    PubMed

    Pedroza, Jose E; Torrealba, Ysidora; Elias, Augusto; Psoter, Walter

    2007-01-01

    The aims of this study were twofold: to compare the static compressive strength at the implant-abutment interface of 3 design systems and to describe the implant abutment connection failure mode. A stainless steel holding device was designed to align the implants at 30 degrees with respect to the y-axis. Sixty-nine specimens were used, 23 for each system. A computer-controlled universal testing machine (MTS 810) applied static compression loading by a unidirectional vertical piston until failure. Specimens were evaluated macroscopically for longitudinal displacement, abutment looseness, and screw and implant fracture. Data were analyzed by analysis of variance (ANOVA). The mean compressive strength for the Unipost system was 392.5 psi (SD +/-40.9), for the Spline system 342.8 psi (SD+/-25.8), and for the Screw-Vent system 269.1 psi (SD+/-30.7). The Unipost implant-abutment connection demonstrated a statistically significant superior mechanical stability (P < or = .009) compared with the Spline implant system. The Spline implant system showed a statistically significant higher compressive strength than the Screw-Vent implant system (P < or =.009). Regarding failure mode, the Unipost system consistently broke at the same site, while the other systems failed at different points of the connection. The Unipost system demonstrated excellent fracture resistance to compressive forces; this resistance may be attributed primarily to the diameter of the abutment screw and the 2.5 mm counter bore, representing the same and a unique piece of the implant. The Unipost implant system demonstrated a statistically significant superior compressive strength value compared with the Spline and Screw-Vent systems, at a 30 degrees angulation.

  13. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    PubMed

    Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael

    2015-01-01

    MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were significant differences in experimental procedure times but not in the number of successful biopsies.

  14. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    PubMed

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell

    2011-05-01

    To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading accuracy in the presence of wireless electromagnetic transponders inside a phantom. A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with/without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with/without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit. Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%. The phantom study indicated that the Calypso System's localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems.

  15. Effect of Different Solar Radiation Data Sources on the Variation of Techno-Economic Feasibility of PV Power System

    NASA Astrophysics Data System (ADS)

    Alghoul, M. A.; Ali, Amer; Kannanaikal, F. V.; Amin, N.; Aljaafar, A. A.; Kadhim, Mohammed; Sopian, K.

    2017-11-01

    The aim of this study is to evaluate the variation in techno-economic feasibility of PV power system under different data sources of solar radiation. HOMER simulation tool is used to predict the techno-economic feasibility parameters of PV power system in Baghdad city, Iraq located at (33.3128° N, 44.3615° E) as a case study. Four data sources of solar radiation, different annual capacity shortages percentage (0, 2.5, 5, and 7.5), and wide range of daily load profile (10-100 kWh/day) are implemented. The analyzed parameters of the techno-economic feasibility are COE (/kWh), PV array power capacity (kW), PV electrical production (kWh/year), No. of batteries and battery lifetime (year). The main results of the study revealed the followings: (1) solar radiation from different data sources caused observed to significant variation in the values of the techno-economic feasibility parameters; therefore, careful attention must be paid to ensure the use of an accurate solar input data; (2) Average solar radiation from different data sources can be recommended as a reasonable input data; (3) it is observed that as the size and of PV power system increases, the effect of different data sources of solar radiation increases and causes significant variation in the values of the techno-economic feasibility parameters.

  16. A risk based approach for SSTO/TSTO comparisons

    NASA Astrophysics Data System (ADS)

    Greenberg, Joel S.

    1996-03-01

    An approach has been developed for performing early comparisons of transportation architectures explicitly taking into account quantitative measures of uncertainty and resulting risk. Risk considerations are necessary since the transportation systems are likely to have significantly different levels of risk, both because of differing degrees of freedom in achieving desired performance levels and their different states of development and utilization. The approach considers the uncertainty of achievement of technology goals, effect that the achieved technology level will have on transportation system performance and the relationship between system performance/capability and the ability to accommodate variations in payload mass. The consequences of system performance are developed in terms of nonrecurring, recurring, and the present value of transportation system life cycle costs.

  17. Evaluation of urology residents' perception of surgical theater educational environment.

    PubMed

    Binsaleh, Saleh; Babaeer, Abdulrahman; Rabah, Danny; Madbouly, Khaled

    2015-01-01

    To evaluate surgical theater learning environment perception in urology residents in Saudi Arabia and to investigate association of learning environment perception and stages of residency program, sectors of health care system, and regions of Saudi Arabia. A cross-sectional survey using the surgical theater educational environment measure (STEEM) inventory. The STEEM inventory was used to measure theater learning environment perception of urology residents in Saudi Arabia. Respondents' perception was compared regarding different residency stages, sectors of the health care system, and regions of Saudi Arabia. Internal reliability of the inventory was assessed using the Cronbach α coefficient. Correlation analysis was done using the Spearman ρ coefficient. Of 72 registered residents, 33 (45.8%) completed the questionnaire. The residents perceived their environment less than acceptable (135.9 ± 16.7, 67.95%). No significant differences in perception were found among residents of different program stages, different sectors of health care system, or different regions in Saudi Arabia. Residents from the eastern region perceived the training and teaching domain better (p = 0.025). The inventory showed a high internal consistency with a Cronbach α of 0.862. STEEM survey is an applicable and reliable instrument for assessing the learning environment and training skills of urology residency program in Saudi Arabia. Urology residents in Saudi Arabia perceived the theater learning environment as less than ideal. The perceptions of theater learning environment did not change significantly among different stages of the program, different sectors of health care system, or different training regions of Saudi Arabia assuring the uniformity of urology training all over Saudi Arabia. The training programs should address significant concerns and pay close attention to areas in surgical theater educational environment, which need development and enhancement, mainly planned fashion of training, supportive supervision and hospital environment, and proper coverage and management of workloads. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Arginase distribution in tissues of domestic animals.

    PubMed

    Aminlari, M; Vaseghi, T

    1992-10-01

    1. A new colorimetric method was used for determination of arginase in different tissues of some domestic animals. 2. In all species studied liver was the richest source of arginase. 3. Significant differences were observed in the specific activity of arginase in livers from different species. 4. In all species, besides liver, kidney and brain also contained significant levels of arginase. 5. In the dog, in addition to the three organs mentioned above, lung, heart, spleen and skeletal muscle showed some arginase activity. 6. In sheep and cattle significant arginase activity was observed in the rumen. No differences were observed between epithelial and muscular layers of different parts of digestive system in all species studied. 7. These results are discussed in terms of the possible role of arginase in different tissues of animals.

  19. Chiral Pesticide Pharmacokinetics: A Range of Values

    EPA Science Inventory

    Approximately 30% of pesticides are chiral and used as mixtures of two or more stereoisomers. In biological systems, these stereoisomers can exhibit significantly different pharmacokinetics (absorption, distribution, metabolism, and elimination). In spite of these differences, th...

  20. Evaluating Three Dimensions of Environmental Knowledge and Their Impact on Behaviour

    NASA Astrophysics Data System (ADS)

    Braun, Tina; Dierkes, Paul

    2017-09-01

    This research evaluates the development of three environmental knowledge dimensions of secondary school students after participation in a singular 1-day outdoor education programme. Applying a cross-national approach, system, action-related and effectiveness knowledge levels of students educated in Germany and Singapore were assessed before and after intervention participation. Correlations between single knowledge dimensions and behaviour changes due to the environmental education intervention were examined. The authors applied a pre-, post- and retention test design and developed a unique multiple-choice instrument. Results indicate significant baseline differences in the prevalence of the different knowledge dimensions between subgroups. Both intervention subsamples showed a low presence of all baseline knowledge dimensions. Action-related knowledge levels were higher than those of system and effectiveness knowledge. Subsample-specific differences in performed pro-environmental behaviour were also significant. Both experimental groups showed significant immediate and sustained knowledge increases in the three dimensions after programme participation. Neither of the two control cohorts showed any significant increase in any knowledge dimension. Effectiveness knowledge improved most. The amount of demonstrated environmental actions increased significantly in both intervention groups. Both control cohorts did not show shifts in environmental behaviour. Yet, only weak correlations between any knowledge dimension and behaviour could be found.

  1. Effect of train type on annoyance and acoustic features of the rolling noise.

    PubMed

    Kasess, Christian H; Noll, Anton; Majdak, Piotr; Waubke, Holger

    2013-08-01

    This study investigated the annoyance associated with the rolling noise of different railway stock. Passbys of nine train types (passenger and freight trains) equipped with different braking systems were recorded. Acoustic features showed a clear distinction of the braking system with the A-weighted energy equivalent sound level (LAeq) showing a difference in the range of 10 dB between cast-iron braked trains and trains with disk or K-block brakes. Further, annoyance was evaluated in a psychoacoustic experiment where listeners rated the relative annoyance of the rolling noise for the different train types. Stimuli with and without the original LAeq differences were tested. For the original LAeq differences, the braking system significantly affected the annoyance with cast-iron brakes being most annoying, most likely as a consequence of the increased wheel roughness causing an increased LAeq. Contribution of the acoustic features to the annoyance was investigated revealing that the LAeq explained up to 94% of the variance. For the stimuli without differences in the LAeq, cast-iron braked train types were significantly less annoying and the spectral features explained up to 60% of the variance in the annoyance. The effect of these spectral features on the annoyance of the rolling noise is discussed.

  2. Comparison of Three Commercial Systems for Identification of Yeasts Commonly Isolated in the Clinical Microbiology Laboratory

    PubMed Central

    Wadlin, Jill K.; Hanko, Gayle; Stewart, Rebecca; Pape, John; Nachamkin, Irving

    1999-01-01

    We evaluated three commercial systems (RapID Yeast Plus System; Innovative Diagnostic Systems, Norcross, Ga.; API 20C Aux; bioMerieux-Vitek, Hazelwood, Mo.; and Vitek Yeast Biochemical Card, bioMerieux-Vitek) against an auxinographic and microscopic morphologic reference method for the ability to identify yeasts commonly isolated in our clinical microbiology laboratory. Two-hundred one yeast isolates were compared in the study. The RapID Yeast Plus System was significantly better than either API 20C Aux (193 versus 167 correct identifications; P < 0.0001) or the Vitek Yeast Biochemical Card (193 versus 173 correct identifications; P = 0.003) for obtaining correct identifications to the species level without additional testing. There was no significant difference between results obtained with API 20C Aux and the Vitek Yeast Biochemical Card system (P = 0.39). The API 20C Aux system did not correctly identify any of the Candida krusei isolates (n = 23) without supplemental testing and accounted for the major differences between the API 20C Aux and RapID Yeast Plus systems. Overall, the RapID Yeast Plus System was easy to use and is a good system for the routine identification of clinically relevant yeasts. PMID:10325356

  3. Does systemic steroid deficiency affect inner ear functions?

    PubMed

    Dogan, Remzi; Merıc, Ayşenur; Gedık, Ozge; Tugrul, Selahattin; Eren, Sabri Baki; Ozturan, Orhan

    2015-01-01

    Today corticosteroids are employed for the treatment of various inner ear disorders. In this study we have investigated probable changes in hearing functions resulting from a deficiency of systemic steroid secretions. Twenty four healthy female rats were used in our study, allocated into three groups (medical adrenalectomy, medical adrenalectomy+dexamethasone, no treatment). Audiological evaluations were conducted at the beginning of the study and on days 7, 14 and 21. Blood samples were taken at the beginning and at the end of the study and blood corticosterone levels were determined. While there were no significant differences between the basal, 7th, 14th and 21st day DPOAE values of group 1, their ABR threshold values showed significant increases. In group 2, there were no significant differences between the basal, 7th, 14th and 21st day DPOAE values. ABR thresholds of group 2 showed significant increases on days 7 and 14 as compared to their basal values, but there were no significant differences between the 21st day and basal ABR threshold values. There were no significant differences between the basal cortisol levels of the three groups. The mean cortisol level of group 1 on day 21 was found to be significantly lower than those of groups 2 and 3. The results of the study demonstrated that there were no significant changes in DPOAE values with the cessation of cortisol secretion, while there was a progressive increase in ABR thresholds, which could be overcome with cortisone replacement. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Effects of Different Tillage and Straw Return on Soil Organic Carbon in a Rice-Wheat Rotation System

    PubMed Central

    Zhu, Liqun; Hu, Naijuan; Yang, Minfang; Zhan, Xinhua; Zhang, Zhengwen

    2014-01-01

    Soil management practices, such as tillage method or straw return, could alter soil organic carbon (C) contents. However, the effects of tillage method or straw return on soil organic C (SOC) have showed inconsistent results in different soil/climate/cropping systems. The Yangtze River Delta of China is the main production region of rice and wheat, and rice-wheat rotation is the most important cropping system in this region. However, few studies in this region have been conducted to assess the effects of different tillage methods combined with straw return on soil labile C fractions in the rice-wheat rotation system. In this study, a field experiment was used to evaluate the effects of different tillage methods, straw return and their interaction on soil total organic C (TOC) and labile organic C fractions at three soil depths (0–7, 7–14 and 14–21 cm) for a rice-wheat rotation in Yangzhong of the Yangtze River Delta of China. Soil TOC, easily oxidizable C (EOC), dissolved organic C (DOC) and microbial biomass C (MBC) contents were measured in this study. Soil TOC and labile organic C fractions contents were significantly affected by straw returns, and were higher under straw return treatments than non-straw return at three depths. At 0–7 cm depth, soil MBC was significantly higher under plowing tillage than rotary tillage, but EOC was just opposite. Rotary tillage had significantly higher soil TOC than plowing tillage at 7–14 cm depth. However, at 14–21 cm depth, TOC, DOC and MBC were significantly higher under plowing tillage than rotary tillage except for EOC. Consequently, under short-term condition, rice and wheat straw both return in rice-wheat rotation system could increase SOC content and improve soil quality in the Yangtze River Delta. PMID:24586434

  5. Validity of two alternative systems for measuring vertical jump height.

    PubMed

    Leard, John S; Cirillo, Melissa A; Katsnelson, Eugene; Kimiatek, Deena A; Miller, Tim W; Trebincevic, Kenan; Garbalosa, Juan C

    2007-11-01

    Vertical jump height is frequently used by coaches, health care professionals, and strength and conditioning professionals to objectively measure function. The purpose of this study is to determine the concurrent validity of the jump and reach method (Vertec) and the contact mat method (Just Jump) in assessing vertical jump height when compared with the criterion reference 3-camera motion analysis system. Thirty-nine college students, 25 females and 14 males between the ages of 18 and 25 (mean age 20.65 years), were instructed to perform the countermovement jump. Reflective markers were placed at the base of the individual's sacrum for the 3-camera motion analysis system to measure vertical jump height. The subject was then instructed to stand on the Just Jump mat beneath the Vertec and perform the jump. Measurements were recorded from each of the 3 systems simultaneously for each jump. The Pearson r statistic between the video and the jump and reach (Vertec) was 0.906. The Pearson r between the video and contact mat (Just Jump) was 0.967. Both correlations were significant at the 0.01 level. Analysis of variance showed a significant difference among the 3 means F(2,235) = 5.51, p < 0.05. The post hoc analysis showed a significant difference between the criterion reference (M = 0.4369 m) and the Vertec (M = 0.3937 m, p = 0.005) but not between the criterion reference and the Just Jump system (M = 0.4420 m, p = 0.972). The Just Jump method of measuring vertical jump height is a valid measure when compared with the 3-camera system. The Vertec was found to have a high correlation with the criterion reference, but the mean differed significantly. This study indicates that a higher degree of confidence is warranted when comparing Just Jump results with a 3-camera system study.

  6. Neurokinin-1 receptor: functional significance in the immune system in reference to selected infections and inflammation

    PubMed Central

    Douglas, Steven D.; Leeman, Susan E.

    2010-01-01

    The G-protein coupled receptor (GPCR), Neurokinin-1 Receptor (NK1R), and its preferred ligand, substance P (SP), are reviewed in relationship to the immune system and selected infections. NK1R and substance P are ubiquitous throughout the animal kingdom. This important pathway has unique functions in numerous cells and tissues. The interaction of SP with its preferred receptor, NK1R, leads to the activation of nuclear factor-kappa-b (NF-κb) and proinflammatory cytokines. NK1R has two isoforms, both a full-length and a truncated form. These isoforms have different functional significances and differ in cell signaling capability. The proinflammatory signals modulated by substance P are important in bacterial, viral, fungal, and parasitic diseases, as well as in immune system function. The SP-NK1R system is a major Class 1, rhodopsin-like GPCR ligand-receptor interaction. PMID:21091716

  7. Environmental Immunology: Lessons learned from exposure to a select panel of immunotoxicants

    PubMed Central

    Kreitinger, Joanna M.; Beamer, Celine A.; Shepherd, David M.

    2016-01-01

    Exposure to environmental contaminants can produce profound effects on the immune system. Many different classes of xenobiotics can significantly suppress or enhance immune responsiveness depending on the levels (i.e. dose) and context (i.e. timing, route) of exposure. While defining the effects that toxicants can have on the immune system is a valuable component to improving public health, environmental immunology has greatly enhanced our understanding of how the immune system functions and explore new immunotherapies. This Brief Review focuses on three different examples of how immunotoxicology has benefitted the field of immunology, presenting information on (A) the aryl hydrocarbon receptor (AhR) signaling pathway, (B) the immunomodulatory effects of nanomaterials, and (C) the impact of xenobiotic exposure on the developing immune system. Collectively, contributions from immunotoxicology have significantly enhanced public health and spurred seminal advances in both basic and applied immunology. PMID:27044635

  8. The system evaluation for report writing skills of summary by HGA-SVM with Ontology: Medical case study in problem based learning

    NASA Astrophysics Data System (ADS)

    Yenaeng, Sasikanchana; Saelee, Somkid; Samai, Wirachai

    2018-01-01

    The system evaluation for report writing skills of summary by Hybrid Genetic Algorithm-Support Vector Machines (HGA-SVM) with Ontology of Medical Case Study in Problem Based Learning (PBL) is a system was developed as a guideline of scoring for the facilitators or medical teacher. The essay answers come from medical student of medical education courses in the nervous system motion and Behavior I and II subject, a third year medical student 20 groups of 9-10 people, the Faculty of Medicine in Prince of Songkla University (PSU). The audit committee have the opinion that the ratings of individual facilitators are inadequate, this system to solve such problems. In this paper proposes a development of the system evaluation for report writing skills of summary by HGA-SVM with Ontology of medical case study in PBL which the mean scores of machine learning score and humans (facilitators) score were not different at the significantly level .05 all 3 essay parts contain problem essay part, hypothesis essay part and learning objective essay part. The result show that, the average score all 3 essay parts that were not significantly different from the rate at the level of significance .05.

  9. Local Inflammation in Fracture Hematoma: Results from a Combined Trauma Model in Pigs

    PubMed Central

    Horst, K.; Eschbach, D.; Pfeifer, R.; Hübenthal, S.; Sassen, M.; Steinfeldt, T.; Wulf, H.; Ruchholtz, S.; Pape, H. C.; Hildebrand, F.

    2015-01-01

    Background. Previous studies showed significant interaction between the local and systemic inflammatory response after severe trauma in small animal models. The purpose of this study was to establish a new combined trauma model in pigs to investigate fracture-associated local inflammation and gain information about the early inflammatory stages after polytrauma. Material and Methods. Combined trauma consisted of tibial fracture, lung contusion, liver laceration, and controlled hemorrhage. Animals were mechanically ventilated and under ICU-monitoring for 48 h. Blood and fracture hematoma samples were collected during the time course of the study. Local and systemic levels of serum cytokines and diverse alarmins were measured by ELISA kit. Results. A statistical significant difference in the systemic serum values of IL-6 and HMGB1 was observed when compared to the sham. Moreover, there was a statistical significant difference in the serum values of the fracture hematoma of IL-6, IL-8, IL-10, and HMGB1 when compared to the systemic inflammatory response. However a decrease of local proinflammatory concentrations was observed while anti-inflammatory mediators increased. Conclusion. Our data showed a time-dependent activation of the local and systemic inflammatory response. Indeed it is the first study focusing on the local and systemic inflammatory response to multiple-trauma in a large animal model. PMID:25694748

  10. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration

    PubMed Central

    Sirisathit, Issarawas

    2018-01-01

    Objective This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. Materials and methods A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05). Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05). Conclusion Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration. PMID:29497334

  11. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth

    PubMed Central

    Govindaraju, Lavanya; Subramanian, EMG

    2017-01-01

    Introduction Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth. PMID:29207834

  12. Comparison of apical and coronal extrusions using reciprocating and rotary instrumentation systems.

    PubMed

    Lu, Yan; Chen, Min; Qiao, Feng; Wu, Ligeng

    2015-08-07

    The aim of this study was to compare the apical and coronal extrusions by using two reciprocating and two rotary instrumentation systems. Eighty extracted human single-rooted anterior teeth were randomly assigned to four groups. Four different root canal instrumentation systems were used according to the manufacturers instructions, including two reciprocating single-file systems, Reciproc and WaveOne, and two full-sequence rotary BLX and ProTaper instruments. Debris collected from the coronal by the instruments and apical extrusions were quantified respectively. After drying the collections, the mean weight of debris collected from apical and coronal extrusions was assessed using an electronic balance and analyzed using the Kruskal-Wallis H and Mann-Whitney U tests. Statistically significant differences in the apical extrusion were observed among the four groups. Reciproc and WaveOne instruments produced significantly less debris than BLX and ProTaper instruments (P < 0.05). All of the systems produced apical extrusion of debris. However, reciprocating single-file systems produced less apical extrusion than full-sequence rotary systems. No relationship was observed between apical and coronal extrusions.

  13. A comparative analysis of user preference-based and existing knowledge management systems attributes in the aerospace industry

    NASA Astrophysics Data System (ADS)

    Varghese, Nishad G.

    Knowledge management (KM) exists in various forms throughout organizations. Process documentation, training courses, and experience sharing are examples of KM activities performed daily. The goal of KM systems (KMS) is to provide a tool set which serves to standardize the creation, sharing, and acquisition of business critical information. Existing literature provides numerous examples of targeted evaluations of KMS, focusing on specific system attributes. This research serves to bridge the targeted evaluations with an industry-specific, holistic approach. The user preferences of aerospace employees in engineering and engineering-related fields were compared to profiles of existing aerospace KMS based on three attribute categories: technical features, system administration, and user experience. The results indicated there is a statistically significant difference between aerospace user preferences and existing profiles in the user experience attribute category, but no statistically significant difference in the technical features and system administration attribute categories. Additional analysis indicated in-house developed systems exhibit higher technical features and user experience ratings than commercial-off-the-self (COTS) systems.

  14. Assessment of Two Different Drinking Water Treatment Plants for the Removal of Free-living Amoebae, Egypt.

    PubMed

    Al-Herrawy, Ahmad Z; Gad, Mahmoud A

    2017-01-01

    The aim of this study was to compare between slow and rapid sand filters for the removal of free-living amoebae during drinking water treatment production. Overall, 48 water samples were collected from two drinking water treatment plants having two different filtration systems (slow and rapid sand filters) and from inlet and outlet of each plant. Water samples were collected from Fayoum Drinking Water and Wastewater Holding Company, Egypt, during the year 2015. They were processed for detection of FLAs using non-nutrient agar (NNA). The isolates of FLAs were microscopically identified to the genus level based on the morphologic criteria and molecularly confirmed by the aid of PCR using genus-specific primers. The percentage of removal for FLAs through different treatment processes reached its highest rate in the station using slow sand filters (83%), while the removal by rapid sand filter system was 71.4%. Statistically, there was no significant difference ( P =0.55) for the removal of FLAs between the two different drinking water treatment systems. Statistically, seasons had no significant effect on the prevalence of FLAs in the two different drinking water treatment plants. Morphological identification of the isolated FLAs showed the presence of 3 genera namely Acanthamoeba , Naegleria , and Vermamoeba ( Hartmannella ) confirmed by PCR. The appearance of FLAs especially pathogenic amoebae in completely treated drinking water may cause potential health threat although there is no statistical difference between the two examined drinking water filtration systems.

  15. 40 CFR 1042.836 - Marine certification of locomotive remanufacturing systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ENGINES AND VESSELS Special Provisions for Remanufactured Marine Engines § 1042.836 Marine certification... of your intent to use your remanufacturing system for marine engines. Include a list of marine engine models for which your system may be used. (2) If there are significant differences in how your...

  16. 40 CFR 1042.836 - Marine certification of locomotive remanufacturing systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENGINES AND VESSELS Special Provisions for Remanufactured Marine Engines § 1042.836 Marine certification... of your intent to use your remanufacturing system for marine engines. Include a list of marine engine models for which your system may be used. (2) If there are significant differences in how your...

  17. 40 CFR 1042.836 - Marine certification of locomotive remanufacturing systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENGINES AND VESSELS Special Provisions for Remanufactured Marine Engines § 1042.836 Marine certification... of your intent to use your remanufacturing system for marine engines. Include a list of marine engine models for which your system may be used. (2) If there are significant differences in how your...

  18. 40 CFR 1042.836 - Marine certification of locomotive remanufacturing systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ENGINES AND VESSELS Special Provisions for Remanufactured Marine Engines § 1042.836 Marine certification... of your intent to use your remanufacturing system for marine engines. Include a list of marine engine models for which your system may be used. (2) If there are significant differences in how your...

  19. 40 CFR 1042.836 - Marine certification of locomotive remanufacturing systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENGINES AND VESSELS Special Provisions for Remanufactured Marine Engines § 1042.836 Marine certification... of your intent to use your remanufacturing system for marine engines. Include a list of marine engine models for which your system may be used. (2) If there are significant differences in how your...

  20. The impact of system level factors on treatment timeliness: utilizing the Toyota Production System to implement direct intake scheduling in a semi-rural community mental health clinic.

    PubMed

    Weaver, Addie; Greeno, Catherine G; Goughler, Donald H; Yarzebinski, Kathleen; Zimmerman, Tina; Anderson, Carol

    2013-07-01

    This study examined the effect of using the Toyota Production System (TPS) to change intake procedures on treatment timeliness within a semi-rural community mental health clinic. One hundred randomly selected cases opened the year before the change and 100 randomly selected cases opened the year after the change were reviewed. An analysis of covariance demonstrated that changing intake procedures significantly decreased the number of days consumers waited for appointments (F(1,160) = 4.9; p = .03) from an average of 11 to 8 days. The pattern of difference on treatment timeliness was significantly different between adult and child programs (F(1,160) = 4.2; p = .04), with children waiting an average of 4 days longer than adults for appointments. Findings suggest that small system level changes may elicit important changes and that TPS offers a valuable model to improve processes within community mental health settings. Results also indicate that different factors drive adult and children's treatment timeliness.

  1. A review on optical actuators for microfluidic systems

    NASA Astrophysics Data System (ADS)

    Yang, Tie; Chen, Yue; Minzioni, Paolo

    2017-12-01

    During the last few decades microfluidic systems have become more and more popular and their relevance in different fields is continually growing. In fact, the use of microchannels allows a significant reduction of the required sample-volume and opens the way to a completely new set of possible investigations, including the study of the properties of cells, the development of new cells’ separation techniques and the analysis of single-cell proteins. One of the main differences between microscopic and macroscopic systems is obviously dictated by the need for suitable actuation mechanisms, which should allow precise control of microscopic fluid volumes and of micro-samples inside the fluid. Even if both syringe-pump and pneumatic-pump technologies significantly evolved and they currently enable sub-μL samples control, completely new approaches were recently developed for the manipulation of samples inside the microchannel. This review is dedicated to describing different kinds of optical actuators that can be applied in microfluidic systems for sample manipulation as well as for pumping. The basic principles underlying the optical actuation mechanisms will be described first, and then several experimental demonstrations will be reviewed and compared.

  2. The Impact of System Level Factors on Treatment Timeliness: Utilizing the Toyota Production System to Implement Direct Intake Scheduling in a Semi-Rural Community Mental Health Clinic

    PubMed Central

    Weaver, A.; Greeno, C.G.; Goughler, D.H.; Yarzebinski, K.; Zimmerman, T.; Anderson, C.

    2013-01-01

    This study examined the effect of using the Toyota Production System (TPS) to change intake procedures on treatment timeliness within a semi-rural community mental health clinic. One hundred randomly selected cases opened the year before the change and one hundred randomly selected cases opened the year after the change were reviewed. An analysis of covariance (ANCOVA) demonstrated that changing intake procedures significantly decreased the number of days consumers waited for appointments (F(1,160)=4.9; p=.03) from an average of 11 days to 8 days. The pattern of difference on treatment timeliness was significantly different between adult and child programs (F(1,160)=4.2; p=.04), with children waiting an average of 4 days longer than adults for appointments. Findings suggest that small system level changes may elicit important changes and that TPS offers a valuable model to improve processes within community mental health settings. Results also indicate that different factors drive adult and children’s treatment timeliness. PMID:23576137

  3. Dependence of palmar sweating response and central nervous system activity on the frequency of whole-body vibration.

    PubMed

    Ando, Hideo; Noguchi, Ryo

    2003-06-01

    This study was carried out to determine the effects of the frequency of whole-body vibration on palmar sweating response and the activity of the central sympathetic nervous system. Palmar sweating volume was measured on the right palm of six healthy men before and during 3 minutes of exposure to sinusoidal whole-body vibration at three different frequencies (16, 31.5, and 63 Hz). The whole-body vibration had a frequency-weighted, root mean square (rms) acceleration magnitude of 2.0 m/s2. As the index of the activated central sympathetic nervous system, saliva level of 3-methoxy-4-hydroxyphenylglycol (MHPG) was analyzed before and immediately after each vibration exposure. Each vibration frequency induced a palmar sweating response, that of 31.5 Hz being the largest. However, no significant difference was found between the three vibration conditions. Saliva MHPG increased in all the vibration exposures, and the largest change was observed at 31.5 Hz, the difference being significant. Acute exposure to whole-body vibration induced a palmar sweating response and activated the central sympathetic nervous system. The effects on the central nervous system were found to be dependent on the frequency of the vibration.

  4. DBP formation in hot and cold water across a simulated distribution system: effect of incubation time, heating time, pH, chlorine dose, and incubation temperature.

    PubMed

    Liu, Boning; Reckhow, David A

    2013-10-15

    This paper demonstrates that disinfection byproducts (DBP) concentration profiles in heated water were quite different from the DBP concentrations in the cold tap water. Chloroform concentrations in the heated water remained constant or even decreased slightly with increasing distribution system water age. The amount of dichloroacetic acid (DCAA) was much higher in the heated water than in the cold water; however, the maximum levels in heated water with different distribution system water ages did not differ substantially. The levels of trichloroacetic acid (TCAA) in the heated water were similar to the TCAA levels in the tap water, and a slight reduction was observed after the tap water was heated for 24 h. Regardless of water age, significant reductions of nonregulated DBPs were observed after the tap water was heated for 24 h. For tap water with lower water ages, there were significant increases in dichloroacetonitrile (DCAN), chloropicrin (CP), and 1,1-dichloropropane (1,1-DCP) after a short period of heating. Heating of the tap water with low pH led to a more significant increase of chloroform and a more significant short-term increase of DCAN. High pH accelerated the loss of the nonregulated DBPs in the heated water. The results indicated that as the chlorine doses increased, levels of chloroform and DCAA in the heated water increased significantly. However, for TCAA, the thermally induced increase in concentration was only notable for the chlorinated water with very high chlorine dose. Finally, heating may lead to higher DBP concentrations in chlorinated water with lower distribution system temperatures.

  5. Visual/motion cue mismatch in a coordinated roll maneuver

    NASA Technical Reports Server (NTRS)

    Shirachi, D. K.; Shirley, R. S.

    1981-01-01

    The effects of bandwidth differences between visual and motion cueing systems on pilot performance for a coordinated roll task were investigated. Visual and motion cue configurations which were acceptable and the effects of reduced motion cue scaling on pilot performance were studied to determine the scale reduction threshold for which pilot performance was significantly different from full scale pilot performance. It is concluded that: (1) the presence or absence of high frequency error information in the visual and/or motion display systems significantly affects pilot performance; and (2) the attenuation of motion scaling while maintaining other display dynamic characteristics constant, affects pilot performance.

  6. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  7. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  8. Influence of an oxygen-inhibited layer on enamel bonding of dental adhesive systems: surface free-energy perspectives.

    PubMed

    Ueta, Hirofumi; Tsujimoto, Akimasa; Barkmeier, Wayne W; Oouchi, Hajime; Sai, Keiichi; Takamizawa, Toshiki; Latta, Mark A; Miyazaki, Masashi

    2016-02-01

    The influence of an oxygen-inhibited layer (OIL) on the shear bond strength (SBS) to enamel and surface free-energy (SFE) of adhesive systems was investigated. The adhesive systems tested were Scotchbond Multipurpose (SM), Clearfil SE Bond (CS), and Scotchbond Universal (SU). Resin composite was bonded to bovine enamel surfaces to determine the SBS, with and without an OIL, of adhesives. The SFE of cured adhesives with and without an OIL were determined by measuring the contact angles of three test liquids. There were no significant differences in the mean SBS of SM and CS specimens with or without an OIL; however, the mean SBS of SU specimens with an OIL was significantly higher than that of SU specimens without an OIL. For all three systems, the mean total SFE (γS), polarity force (γSp), and hydrogen bonding force (γSh) values of cured adhesives with an OIL were significantly higher than those of cured adhesives without an OIL. The results of this study indicate that the presence of an OIL promotes higher SBS of a single-step self-etch adhesive system, but not of a three-step or a two-step self-etch primer system. The SFE values of cured adhesives with an OIL were significantly higher than those without an OIL. The SFE characteristics of the OIL of adhesives differed depending on the type of adhesive. © 2015 Eur J Oral Sci.

  9. Association of periodontal disease with systemic health indices in dogs and the systemic response to treatment of periodontal disease.

    PubMed

    Rawlinson, Jennifer E; Goldstein, Richard E; Reiter, Alexander M; Attwater, Daniel Z; Harvey, Colin E

    2011-03-01

    To determine whether severity of periodontal disease (PD) was associated with systemic health indices in dogs and whether treatment of PD altered systemic health indices. Prospective cohort study. 38 dogs. Healthy dogs with clinical signs of PD were included in the study. Physical examination, serum biochemical analysis, a CBC, urine evaluation, measurement of serum C-reactive protein (CRP) concentration, and a microalbuminuria test were performed prior to treatment of PD. All tooth roots were scored for gingivitis and attachment loss, and appropriate treatment of PD was performed. Laboratory data were obtained 4 weeks after treatment. The Spearman rank correlation and Wilcoxon signed rank test were used for statistical analysis. Analyses of the correlation of several variables with attachment loss or gingivitis or of differences before and after treatment revealed significant results for several variables. After applying Bonferroni corrections for family-wise error rate, significant rank correlations were found between attachment loss and platelet number (r = 0.54), creatinine concentration (r = -0.49), and the within-dog difference in CRP concentrations before and after treatment (r = 0.40). The BUN concentration was significantly higher after treatment than before treatment. Increasing severity of attachment loss was associated with changes in systemic inflammatory variables and renal indices. A decrease in CRP concentration after treatment was correlated with the severity of PD. The BUN concentration increased significantly after treatment of PD. There is a need for continued research into the systemic impact of PD.

  10. Comparison of respiratory system impedance in asthma and COPD: A prospective observational study.

    PubMed

    Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi

    2018-05-01

    A single assessment of within-breath variations of respiratory system reactance (Xrs) at 5 Hz (ΔX5) measured by the forced oscillation technique (FOT) has been reported to be useful for the detection of pathophysiological changes in chronic obstructive pulmonary disease (COPD) and asthma. We examined longitudinal changes in respiratory system resistance (Rrs) and Xrs during tidal breathing between stable asthma and COPD patients in order to clarify the features of changes of respiratory system impedance and airflow limitation for these conditions. Between April 2013 and September 2013, outpatients with a COPD or asthma diagnosis were recruited. We examined forced expiratory volume in 1 s (FEV 1 ) and FOT every 6 months until September 2015. Annual changes were estimated from the linear regression curve slope. We included 57 and 93 subjects with COPD and asthma, respectively. The median follow-up period was 26 months (range: 24-29 months). Within-breath analysis showed that the difference between mean Rrs at 5 Hz and 20 Hz was significantly lower, and ΔX5 more negative, in COPD than in asthma patients. With regard to annual changes, only ΔX5 was significantly different, more negative, in COPD than in asthma patients. Comparing between COPD subjects of Global Initiative Chronic Obstructive Lung Disease (GOLD) stage I/II and those with asthma, there were no significant differences in respiratory system impedance at enrolment, while annual change in ΔX5 was significantly more negative in mild COPD than in asthma patients. ΔX5 may be useful for long-term assessment of airflow limitation in COPD. © 2018 Asian Pacific Society of Respirology.

  11. Evaluation of feed and feeding regime on growth performance, flesh quality and fecal viscosity of Atlantic salmon ( Salmo salar L.) in recirculating aquaculture systems

    NASA Astrophysics Data System (ADS)

    Sun, Guoxiang; Liu, Ying; Li, Yong; Li, Xian; Wang, Shunkui

    2015-10-01

    The effects of different feeds and feeding regimes on growth performance, flesh quality and fecal viscosity of Atlantic salmon ( Salmo salar L.) in recirculating aquaculture systems (RAS) were investigated. Fish (initial body weight of 1677 g ± 157 g) were fed with four commercial feeds (Nosan salmon-NS, Aller gold-AG, Skretting salmon-SS and Han ye-HY) in two feeding regimes (80% and 100% satiation) for 78 d. The results showed that salmon specific growth ratio (SGR) and weight gain ratio (WGR) were significantly affected by feed type and feeding regime ( P < 0.05). Feed conversion ratio (FCR) varied between 0.93 and 3.40, which was significantly affected by feed type ( P < 0.05), and slightly improved with increased satiation degree. The activities of digestive enzymes including protease, lipase and amylase were also significantly affected by feed type and feeding regime ( P < 0.05), increasing with satiation degree. Flesh qualities for vitamin E, hydroxyproline (HYP), liquid loss and muscle pH among all groups showed significant differences ( P < 0.05), ranging from 26.67 to 29.67, while no obvious difference was found in flesh color. Fecal viscosity for different treatments showed no significant difference, though improvement was found in 100% satiation group. From present experiment, it was concluded that both feed type and feeding regime can affect the important quality attributes of Atlantic salmon.

  12. Differences in glance behavior between drivers using a rearview camera, parking sensor system, both technologies, or no technology during low-speed parking maneuvers.

    PubMed

    Kidd, David G; McCartt, Anne T

    2016-02-01

    This study characterized the use of various fields of view during low-speed parking maneuvers by drivers with a rearview camera, a sensor system, a camera and sensor system combined, or neither technology. Participants performed four different low-speed parking maneuvers five times. Glances to different fields of view the second time through the four maneuvers were coded along with the glance locations at the onset of the audible warning from the sensor system and immediately after the warning for participants in the sensor and camera-plus-sensor conditions. Overall, the results suggest that information from cameras and/or sensor systems is used in place of mirrors and shoulder glances. Participants with a camera, sensor system, or both technologies looked over their shoulders significantly less than participants without technology. Participants with cameras (camera and camera-plus-sensor conditions) used their mirrors significantly less compared with participants without cameras (no-technology and sensor conditions). Participants in the camera-plus-sensor condition looked at the center console/camera display for a smaller percentage of the time during the low-speed maneuvers than participants in the camera condition and glanced more frequently to the center console/camera display immediately after the warning from the sensor system compared with the frequency of glances to this location at warning onset. Although this increase was not statistically significant, the pattern suggests that participants in the camera-plus-sensor condition may have used the warning as a cue to look at the camera display. The observed differences in glance behavior between study groups were illustrated by relating it to the visibility of a 12-15-month-old child-size object. These findings provide evidence that drivers adapt their glance behavior during low-speed parking maneuvers following extended use of rearview cameras and parking sensors, and suggest that other technologies which augment the driving task may do the same. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Gender differences in undergraduate medicine in Galway: a tale of two curricula.

    PubMed

    McVeigh, T P; Dunne, F P

    2014-03-01

    Medical teaching in the National University of Ireland Galway (NUIG) has undergone a shift from subject- to system-based learning. Our aims were to examine differences between genders in academic performance in medicine across two different curricula. Results of each student graduating between 2007 and 2012 for each subject undertaken over the medical degree were obtained from the Medical School. Data were collected with respect to gender, nationality and mode of entry, and analysis completed using SPSS. The cohort included 360 females and 249 males. 396 students read from a subject-based curriculum and 213 a system-based course. Females outperformed males in 19/24 (79 %) subjects in the subject-based curriculum, and in 9/38 (24 %) in the system-based course. Males were more likely to fail and less likely to achieve an honours degree. Multivariate analysis showed nationality and gender to be significant predictive factors. Females outperformed males overall. Differences were most pronounced in a subject-based curriculum. Nationality and gender were found to be significant factors in determining overall results.

  14. The influence of percutaneous nephrolithotomy on human systemic stress response, SIRS and renal function.

    PubMed

    Shen, Pengfei; Wei, Wuran; Yang, Xiaochun; Zeng, Hao; Li, Xiong; Yang, Jie; Wang, Jia; Huang, Jiaoti

    2010-10-01

    The objective of this study is to investigate the influences of percutaneous nephrolithotomy (PNL) and open surgery nephrolithotomy on the systemic stress response, SIRS and renal function. Forty patients with kidney calculi were enrolled in the study. Twenty cases were randomized to the PNL group and the other twenty cases to the open surgery group. Levels of C-reactive protein (CRP), interleukin-6(IL-6), β(2)-microglobulin (β(2)-MG), respiration rate, heart rate, body temperature and white blood cell counts were examined. CRP and IL-6 were measured in all patients pre-operatively and on post-operative days 1, 3 and 6, respectively. There was significant difference in their pre- and post-operation levels (P < 0.05), with the peak of CRP and IL-6 observed at post-operative days 3 and 1, respectively. There was significant difference in both CRP and IL-6 between the two groups (P < 0.05). At post-operative day 1, there were 5 cases of SIRS in PNL group and 12 cases in open surgery group; there was significant difference between the two groups (P < 0.05). Serum β(2)-MG levels were measured as the same time as CRP and no significant changes were observed within or between the groups (P > 0.05). Urine β(2)-MG levels were also measured. There was significant difference between pre- and the first day post-PNL (P < 0.05); there was no significant difference between pre- and the third and sixth day post-PNL (P > 0.05). There was significant difference between pre- and first and third day post-open surgery (P < 0.05); but there was no significant difference between pre- and the sixth day post-open surgery (P > 0.05). There was significant difference between two groups at the first, third and sixth days (P < 0.05). The systemic stress response is activated both in PNL group and open surgery group to some extent. The degree of stress response of PNL is lower than that of open surgery, proving the advantages of PNL with reference to serum immunology. There were cases in both the groups with SIRS, but the degree of SIRS in PNL group was lesser than the other group. Both the groups have no obvious effect on glomerular filtration function after operation and have effect on renal tubular reabsorption in the early stage after operation; but the recovery of the PNL group is faster than the open surgery group. It is thus shown that PNL is much safer and more feasible and has lesser effect on renal function.

  15. Activation of the mesocortical dopamine system by feeding: lack of a selective response to stress.

    PubMed

    Taber, M T; Fibiger, H C

    1997-03-01

    There is wide agreement that catecholamine systems in the prefrontal cortex are activated by stressful stimuli. To date, however, the extent to which other stimuli can increase the activity of these systems has received little attention. In the present study, the effects of tail pinch stress and feeding on dopamine and noradrenaline release in the prefrontal cortex of rats were examined using in vivo brain microdialysis. Both stimuli increased dopamine release, with peak effects reaching 212% above baseline for tail pinch and 165% above baseline for feeding. The effects of the two stimuli on peak dopamine release were not significantly different. Both stimuli also significantly increased noradrenaline release, with peak effects reaching 128% above baseline for tail pinch and 98% above baseline for feeding. The effects of the two stimuli on peak noradrenaline release were not significantly different. These results indicate that activation of catecholaminergic afferents to the prefrontal cortex is not specific to stress, but also occurs in response to non-stressors with positive motivational valence.

  16. Are Epiphytic Microbial Communities in the Carposphere of Ripening Grape Clusters (Vitis vinifera L.) Different between Conventional, Organic, and Biodynamic Grapes?

    PubMed

    Kecskeméti, Elizabeth; Berkelmann-Löhnertz, Beate; Reineke, Annette

    2016-01-01

    Using barcoded pyrosequencing fungal and bacterial communities associated with grape berry clusters (Vitis vinifera L.) obtained from conventional, organic and biodynamic vineyard plots were investigated in two subsequent years at different stages during berry ripening. The four most abundant operational taxonomic units (OTUs) based on fungal ITS data were Botrytis cinerea, Cladosporium spp., Aureobasidium pullulans and Alternaria alternata which represented 57% and 47% of the total reads in 2010 and 2011, respectively. Members of the genera Sphingomonas, Gluconobacter, Pseudomonas, Erwinia, and Massilia constituted 67% of the total number of bacterial 16S DNA reads in 2010 samples and 78% in 2011 samples. Viticultural management system had no significant effect on abundance of fungi or bacteria in both years and at all three sampling dates. Exceptions were A. alternata and Pseudomonas spp. which were more abundant in the carposphere of conventional compared to biodynamic berries, as well as Sphingomonas spp. which was significantly less abundant on conventional compared to organic berries at an early ripening stage in 2011. In general, there were no significant differences in fungal and bacterial diversity indices or richness evident between management systems. No distinct fungal or bacterial communities were associated with the different maturation stages or management systems, respectively. An exception was the last stage of berry maturation in 2011, where the Simpson diversity index was significantly higher for fungal communities on biodynamic compared to conventional grapes. Our study highlights the existence of complex and dynamic microbial communities in the grape cluster carposphere including both phytopathogenic and potentially antagonistic microorganisms that can have a significant impact on grape production. Such knowledge is particularly relevant for development, selection and application of effective control measures against economically important pathogens present in the grape carposphere.

  17. Pediatric normative data for the KayPENTAX phonatory aerodynamic system model 6600.

    PubMed

    Weinrich, Barbara; Brehm, Susan Baker; Knudsen, Courtney; McBride, Stephanie; Hughes, Michael

    2013-01-01

    The objectives of this study were to (1) establish a preliminary pediatric normative database for the KayPENTAX Phonatory Aerodynamic System (PAS) Model 6600 (KayPENTAX Corp, Montvale, NJ) and (2) identify whether the data obtained were age- and/or gender-dependent. Prospective data collection across groups. A sample of 60 children (30 females and 30 males) with normal voices was divided into three age groups (6.0-9.11, 10.0-13.11, 14.0-17.11 years) with equal distribution of males and females within each group. Five PAS protocols (vital capacity, maximum sustained phonation, comfortable sustained phonation, variation in sound pressure level, voicing efficiency) were used to collect 45 phonatory aerodynamic measures. Measurements for the 45 PAS parameters examined revealed 13 parameters to have a difference that was statistically significant by age and/or gender. There was a significant age×gender interaction for mean pitch in the four protocols that reported this measure. Males in the oldest group had significantly lower mean pitch values than the middle and young groups. Statistically significant main effect differences were noted for seven parameters across three age groups (expiratory volume, expiratory airflow duration, phonation time, pitch range (in 2 protocols), aerodynamic resistance, acoustic ohms). Significant main effect differences for genders (males > females) were found for expiratory volume and peak expiratory airflow. The age- and gender-related differences found for some parameters within each of the five protocols are important for the interpretation of data obtained from PAS. These results could be explained by developmental changes that occur in the male and female respiratory and laryngeal systems. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  18. Are Epiphytic Microbial Communities in the Carposphere of Ripening Grape Clusters (Vitis vinifera L.) Different between Conventional, Organic, and Biodynamic Grapes?

    PubMed Central

    Kecskeméti, Elizabeth; Berkelmann-Löhnertz, Beate; Reineke, Annette

    2016-01-01

    Using barcoded pyrosequencing fungal and bacterial communities associated with grape berry clusters (Vitis vinifera L.) obtained from conventional, organic and biodynamic vineyard plots were investigated in two subsequent years at different stages during berry ripening. The four most abundant operational taxonomic units (OTUs) based on fungal ITS data were Botrytis cinerea, Cladosporium spp., Aureobasidium pullulans and Alternaria alternata which represented 57% and 47% of the total reads in 2010 and 2011, respectively. Members of the genera Sphingomonas, Gluconobacter, Pseudomonas, Erwinia, and Massilia constituted 67% of the total number of bacterial 16S DNA reads in 2010 samples and 78% in 2011 samples. Viticultural management system had no significant effect on abundance of fungi or bacteria in both years and at all three sampling dates. Exceptions were A. alternata and Pseudomonas spp. which were more abundant in the carposphere of conventional compared to biodynamic berries, as well as Sphingomonas spp. which was significantly less abundant on conventional compared to organic berries at an early ripening stage in 2011. In general, there were no significant differences in fungal and bacterial diversity indices or richness evident between management systems. No distinct fungal or bacterial communities were associated with the different maturation stages or management systems, respectively. An exception was the last stage of berry maturation in 2011, where the Simpson diversity index was significantly higher for fungal communities on biodynamic compared to conventional grapes. Our study highlights the existence of complex and dynamic microbial communities in the grape cluster carposphere including both phytopathogenic and potentially antagonistic microorganisms that can have a significant impact on grape production. Such knowledge is particularly relevant for development, selection and application of effective control measures against economically important pathogens present in the grape carposphere. PMID:27500633

  19. Development of a 3D ultrasound system to investigate post-hemorrhagic hydrocephalus in pre-term neonates

    NASA Astrophysics Data System (ADS)

    Kishimoto, J.; Lee, D.; St. Lawrence, K.; Romano, W.; Fenster, A.; de Ribaupierre, S.

    2013-03-01

    Clinical intracranial ultrasound (US) is performed as a standard of care on neonates at risk of intraventricular hemorrhaging (IVH) and is also used after a diagnosis to monitor for potential ventricular dilation. However, it is difficult to estimate the volume of ventricles with 2D US due to their irregular shape. We developed a 3D US system to be used as an adjunct to a clinical system to investigate volumetric changes in the ventricles of neonates with IVH. Our system has been found have an error of within 1% of actual distance measurements in all three directions and volume measurements of manually segmented volumes from phantoms were not statistically significantly different from the actual values (p>0.3). Interobserver volume measurements of the lateral ventricles in a patient with grade III IVH found no significant differences between measurements. There is the potential to use this system in IVH patients to monitor the progression of ventriculomegaly over time.

  20. Effects of 17β-estradiol on emissions of greenhouse gases in simulative natural water body.

    PubMed

    Ruan, Aidong; Zhao, Ying; Liu, Chenxiao; Zong, Fengjiao; Yu, Zhongbo

    2015-05-01

    Environmental estrogens are widely spread across the world and are increasingly thought of as serious contaminators. The present study looks at the influence of different concentrations of 17β-estradiol on greenhouse gas emissions (CO2 , CH4 , and N2 O) in simulated systems to explore the relationship between environmental estrogen-pollution and greenhouse gas emissions in natural water bodies. The present study finds that 17β-estradiol pollution in simulated systems has significant promoting effects on the emissions of CH4 and CO2 , although no significant effects on N2 O emissions. The present study indicates that 17β-estradiol has different effects on the different elements cycles; the mechanism of microbial ecology is under review. © 2015 SETAC.

  1. Tissue Penetration of Antifungal Agents

    PubMed Central

    Felton, Timothy; Troke, Peter F.

    2014-01-01

    SUMMARY Understanding the tissue penetration of systemically administered antifungal agents is critical for a proper appreciation of their antifungal efficacy in animals and humans. Both the time course of an antifungal drug and its absolute concentrations within tissues may differ significantly from those observed in the bloodstream. In addition, tissue concentrations must also be interpreted within the context of the pathogenesis of the various invasive fungal infections, which differ significantly. There are major technical obstacles to the estimation of concentrations of antifungal agents in various tissue subcompartments, yet these agents, even those within the same class, may exhibit markedly different tissue distributions. This review explores these issues and provides a summary of tissue concentrations of 11 currently licensed systemic antifungal agents. It also explores the therapeutic implications of their distribution at various sites of infection. PMID:24396137

  2. Radiologic findings in late-onset systemic lupus erythematosus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braunstein, E.M.; Weissman, B.N.; Sosman, J.L.

    1983-03-01

    Systemic lupus erythematosus in the elderly has a different clinical and serologic course from that in young patients. Radiographic findings in patients in whom the diagnosis was made after age 50 were compared with findings in younger patients to see if the radiologic patterns are also different. The only significant radiographic difference between the two groups was that the older group had a greater incidence of soft-tissue swelling of the hands and wrists (p < 0.001). There was no significant difference in osteopenia, erosion, soft-tissue calcification, alignment abnormalities, or intrathoracic findings. Of 24 patients over age 50, two developed lymphomamore » and another developed multiple myeloma. The data agree with clinical observations that there is a higher incidence of arthritis in late-onset lupus, but clinical findings of increased incidence of pleuropericardial disease are not confirmed radiographically. The coincidence of hematologic malignancy with late-onset lupus in this series is noteworthy.« less

  3. Predicting Operator Execution Times Using CogTool

    NASA Technical Reports Server (NTRS)

    Santiago-Espada, Yamira; Latorella, Kara A.

    2013-01-01

    Researchers and developers of NextGen systems can use predictive human performance modeling tools as an initial approach to obtain skilled user performance times analytically, before system testing with users. This paper describes the CogTool models for a two pilot crew executing two different types of a datalink clearance acceptance tasks, and on two different simulation platforms. The CogTool time estimates for accepting and executing Required Time of Arrival and Interval Management clearances were compared to empirical data observed in video tapes and registered in simulation files. Results indicate no statistically significant difference between empirical data and the CogTool predictions. A population comparison test found no significant differences between the CogTool estimates and the empirical execution times for any of the four test conditions. We discuss modeling caveats and considerations for applying CogTool to crew performance modeling in advanced cockpit environments.

  4. Does terrestrial epidemiology apply to marine systems?

    USGS Publications Warehouse

    McCallum, Hamish I.; Kuris, Armand M.; Harvell, C. Drew; Lafferty, Kevin D.; Smith, Garriet W.; Porter, James

    2004-01-01

    Most of epidemiological theory has been developed for terrestrial systems, but the significance of disease in the ocean is now being recognized. However, the extent to which terrestrial epidemiology can be directly transferred to marine systems is uncertain. Many broad types of disease-causing organism occur both on land and in the sea, and it is clear that some emergent disease problems in marine environments are caused by pathogens moving from terrestrial to marine systems. However, marine systems are qualitatively different from terrestrial environments, and these differences affect the application of modelling and management approaches that have been developed for terrestrial systems. Phyla and body plans are more diverse in marine environments and marine organisms have different life histories and probably different disease transmission modes than many of their terrestrial counterparts. Marine populations are typically more open than terrestrial ones, with the potential for long-distance dispersal of larvae. Potentially, this might enable unusually rapid propagation of epidemics in marine systems, and there are several examples of this. Taken together, these differences will require the development of new approaches to modelling and control of infectious disease in the ocean.

  5. [Hepatotoxicity of emodin based on UGT1A1 enzyme-mediated bilirubin in liver microsomes].

    PubMed

    Wang, Qi; Dai, Zhong; Zhang, Yu-Jie; Ma, Shuang-Cheng

    2016-12-01

    To study the hepatotoxicity of emodin based on bilirubin metabolism mediated by glucuronidation of UGT1A1 enzyme. In this study, three different incubation systems were established by using RLM, HLM, and rUGT1A1, with bilirubin as the substrate. Different concentrations of bilirubin and emodin were added in the incubation systems. The double reciprocal Michaelis equation was drawn based on the total amount of bilirubin glucuronidation. The apparent inhibition constant Ki was then calculated with the slope curve to predict the hepatotoxicity. The results indicated that emodin had a significant inhibition to the UGT1A1 enzyme in all of the three systems, with Ki=5.400±0.956(P<0.05) in HLM system, Ki =10.020±0.611(P<0.05) in RLM system, Ki=4.850±0.528(P<0.05) in rUGT1A1 system. Meanwhile, emodin had no significant difference between rat and human in terms of inhibition of UGT1A1 enzyme. Emodin had a potential risk of the hepatotoxicity by inhibiting the UGT1A1 enzyme activity. And the method established in this study provides a new thought and new method to evaluate hepatotoxicity and safety of traditional Chinese medicines. Copyright© by the Chinese Pharmaceutical Association.

  6. Multi-modal demands of a smartphone used to place calls and enter addresses during highway driving relative to two embedded systems.

    PubMed

    Reimer, Bryan; Mehler, Bruce; Reagan, Ian; Kidd, David; Dobres, Jonathan

    2016-12-01

    There is limited research on trade-offs in demand between manual and voice interfaces of embedded and portable technologies. Mehler et al. identified differences in driving performance, visual engagement and workload between two contrasting embedded vehicle system designs (Chevrolet MyLink and Volvo Sensus). The current study extends this work by comparing these embedded systems with a smartphone (Samsung Galaxy S4). None of the voice interfaces eliminated visual demand. Relative to placing calls manually, both embedded voice interfaces resulted in less eyes-off-road time than the smartphone. Errors were most frequent when calling contacts using the smartphone. The smartphone and MyLink allowed addresses to be entered using compound voice commands resulting in shorter eyes-off-road time compared with the menu-based Sensus but with many more errors. Driving performance and physiological measures indicated increased demand when performing secondary tasks relative to 'just driving', but were not significantly different between the smartphone and embedded systems. Practitioner Summary: The findings show that embedded system and portable device voice interfaces place fewer visual demands on the driver than manual interfaces, but they also underscore how differences in system designs can significantly affect not only the demands placed on drivers, but also the successful completion of tasks.

  7. Metabolite profiling on wheat grain to enable a distinction of samples from organic and conventional farming systems.

    PubMed

    Bonte, Anja; Neuweger, Heiko; Goesmann, Alexander; Thonar, Cécile; Mäder, Paul; Langenkämper, Georg; Niehaus, Karsten

    2014-10-01

    Identification of biomarkers capable of distinguishing organic and conventional products would be highly welcome to improve the strength of food quality assurance. Metabolite profiling was used for biomarker search in organic and conventional wheat grain (Triticum aestivum L.) of 11 different old and new bread wheat cultivars grown in the DOK system comparison trial. Metabolites were extracted using methanol and analysed by gas chromatography-mass spectrometry. Altogether 48 metabolites and 245 non-identified metabolites (TAGs) were detected in the cultivar Runal. Principal component analysis showed a sample clustering according to farming systems and significant differences in peak areas between the farming systems for 10 Runal metabolites. Results obtained from all 11 cultivars indicated a greater influence of the cultivar than the farming system on metabolite concentrations. Nevertheless, a t-test on data of all cultivars still detected 5 metabolites and 11 TAGs with significant differences between the farming systems. Based on individual cultivars, metabolite profiling showed promising results for the categorization of organic and conventional wheat. Further investigations are necessary with wheat from more growing seasons and locations before definite conclusions can be drawn concerning the feasibility to evolve a combined set of biomarkers for organically grown wheat using metabolite profiles. © 2014 Society of Chemical Industry.

  8. Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

    PubMed

    De-Deus, Gustavo; Neves, Aline; Silva, Emmanuel João; Mendonça, Thais Accorsi; Lourenço, Caroline; Calixto, Camila; Lima, Edson Jorge Moreira

    2015-03-01

    This study aims to evaluate the apical extrusion of debris by the two reciprocating single-file systems: WaveOne and Reciproc. Conventional multi-file rotary system was used as a reference for comparison. The hypotheses tested were (i) the reciprocating single-file systems extrude more than conventional multi-file rotary system and (ii) the reciprocating single-file systems extrude similar amounts of dentin debris. After solid selection criteria, 80 mesial roots of lower molars were included in the present study. The use of four different instrumentation techniques resulted in four groups (n = 20): G1 (hand-file technique), G2 (ProTaper), G3 (WaveOne), and G4 (Reciproc). The apparatus used to evaluate the collection of apically extruded debris was typical double-chamber collector. Statistical analysis was performed for multiple comparisons. No significant difference was found in the amount of the debris extruded between the two reciprocating systems. In contrast, conventional multi-file rotary system group extruded significantly more debris than both reciprocating groups. Hand instrumentation group extruded significantly more debris than all other groups. The present results yielded favorable input for both reciprocation single-file systems, inasmuch as they showed an improved control of apically extruded debris. Apical extrusion of debris has been studied extensively because of its clinical relevance, particularly since it may cause flare-ups, originated by the introduction of bacteria, pulpal tissue, and irrigating solutions into the periapical tissues.

  9. Shear Bond Strengths and Morphological Evaluation of Filled and Unfilled Adhesive Interfaces to Enamel and Dentine

    PubMed Central

    Mortazavi, Vajihesadat; Fathi, Mohammadhosein; Ataei, Ebrahim; Khodaeian, Niloufar; Askari, Navid

    2012-01-01

    In this laboratory study shear bond strengths of three filled and one unfilled adhesive systems to enamel and dentine were compared. Forty-eight extracted intact noncarious human mandibular molars were randomly assigned to two groups of 24 one for bonding to enamel and the other for bonding to dentine. Buccal and lingual surfaces of each tooth were randomly assigned for application of each one of filled (Prime & Bond NT (PBNT), Optibond Solo Plus (OBSP), and Clearfil SE Bond (CSEB)) and unfilled (Single Bond (SB)) adhesive systems (n = 12). A universal resin composite was placed into the translucent plastic cylinders (3 mm in diameter and 2 mm in length) and seated against the enamel and dentine surfaces and polymerized for 40 seconds. Shear bond strength was determined using a universal testing machine, and the results were statistically analyzed using two-way ANOVA, one-way ANOVA, t-test, and Tukey HSD post hoc test with a 5% level of significance.There were no statistically significant differences in bond strength between the adhesive systems in enamel, but CSEB and SB exhibited significantly higher and lower bond strength to dentine, respectively, than the other tested adhesive systems while there were no statistically significant differences between PBNT and OBSP. PMID:23209471

  10. Effects of diabetes mellitus and systemic arterial hypertension on elderly patients' hearing.

    PubMed

    Rolim, Laurie Penha; Samelli, Alessandra Giannella; Moreira, Renata Rodrigues; Matas, Carla Gentile; Santos, Itamar de Souza; Bensenor, Isabela Martins; Lotufo, Paulo Andrade

    2017-09-21

    Chronic diseases can act as an accelerating factor in the auditory system degeneration. Studies on the association between presbycusis and diabetes mellitus and systemic arterial hypertension have shown controversial conclusions. To compare the initial audiometry (A1) with a subsequent audiometry (A2) performed after a 3 to 4-year interval in a population of elderly patients with diabetes mellitus and/or systemic arterial hypertension, to verify whether hearing loss in these groups is more accelerated when compared to controls without these clinical conditions. 100 elderly individuals participated in this study. For the auditory threshold assessment, a previous complete audiological evaluation (A1) and a new audiological evaluation (A2) performed 3-4 years after the first one was utilized. The participants were divided into four groups: 20 individuals in the diabetes mellitus group, 20 individuals in the systemic arterial hypertension group, 20 individuals in the diabetes mellitus/systemic arterial hypertension group and 40 individuals in the control group, matching them with each study group, according to age and gender. ANOVA and Kruskal-Wallis statistical tests were used, with a significance level set at 0.05. When comparing the mean annual increase in the auditory thresholds of the A1 with the A2 assessment, considering each study group and its respective control, it can be observed that there was no statistically significant difference for any of the frequencies for the diabetes mellitus group; for the systemic arterial hypertension group, significant differences were observed after 4kHz. For the diabetes mellitus and systemic arterial hypertension group, significant differences were observed at the frequencies of 500, 2kHz, 3kHz and 8kHz. It was observed that the systemic arterial hypertension group showed the greatest decrease in auditory thresholds in the studied segment when compared to the other groups, suggesting that among the three studied conditions, hypertension seems to have the greatest influence on hearing. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  11. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

    PubMed

    Bürklein, Sebastian; Schäfer, Edgar

    2012-06-01

    The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-file systems Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and the 2 full-sequence rotary Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments. Bidistilled water was used as irrigant. The apically extruded debris was collected in preweighted glass vials using the Myers and Montgomery method. After drying, the mean weight of debris was assessed with a microbalance and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. The reciprocating files produced significantly more debris compared with both rotary systems (P < .05). Although no statistically significant difference was obtained between the 2 rotary instruments (P > .05), the reciprocating single-file system Reciproc produced significantly more debris compared with all other instruments (P < .05). Instrumentation was significantly faster using Reciproc than with all other instrument (P < .05). Under the condition of this study, all systems caused apical debris extrusion. Full-sequence rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Effect of regional and systemic fluorinated pyrimidine chemotherapy on quality of life in colorectal liver metastasis patients.

    PubMed

    Earlam, S; Glover, C; Davies, M; Fordy, C; Allen-Mersh, T G

    1997-05-01

    Since systemic and regional (HAI) fluorinated pyrimidine chemotherapies offer similar survival benefit in treatment of colorectal liver metastases (CLM), we sought to identify their impact on quality of life (QoL), which might be a useful indicator of treatment preference. We compared QoL in 135 CLM patients managed by symptom control (n = 49 patients), systemic fluorouracil (5FU)/folinic acid (n = 35), or hepatic arterial floxuridine (FUDR) (n = 51). Full blood count and liver function tests, World Health Organization (WHO) toxicity criteria, and QoL (Rotterdam Symptom Checklist [RSC], the Sickness Impact Profile [SIP], and the Hospital Anxiety and Depression scale [HAD]) were measured monthly in all patients. The HAD anxiety score was significantly increased in symptom control compared with chemotherapy patients 1 month after randomization. There was a significant increase in RSC physical score (repeated measures, P = .05), and in scores for sore mouth (P < .01), dry mouth (P < .01), and tingling hands and feet (P < .01) in systemic chemotherapy compared with symptom control patients. Significant QoL differences (repeated measures and Mann-Whitney U [MWU]) between HAI and symptom control patients were not detected. Systemic chemotherapy patients lived for significantly longer (log-rank test, P < or = .0001) with abnormal HAD anxiety, RSC psychosocial, or RSC sore mouth scores compared with HAI patients, but there were no overall survival differences. Randomization to symptom control only was associated with increased anxiety. QoL with systemic chemotherapy was impaired by side effects. HAI was associated with similar survival to systemic chemotherapy but with better sustained QoL.

  13. Insect Venom Immunotherapy: Analysis of the Safety and Tolerance of 3 Buildup Protocols Frequently Used in Spain.

    PubMed

    Gutiérrez Fernández, D; Moreno-Ancillo, A; Fernández Meléndez, S; Domínguez-Noche, C; Gálvez Ruiz, P; Alfaya Arias, T; Carballada González, F; Alonso Llamazares, A; Marques Amat, L; Vega Castro, A; Antolín Amérigo, D; Cruz Granados, S; Ruiz León, B; Sánchez Morillas, L; Fernández Sánchez, J; Soriano Gomis, V; Borja Segade, J; Dalmau Duch, G; Guspi Bori, R; Miranda Páez, A

    2016-01-01

    Hymenoptera venom immunotherapy (VIT) is an effective treatment but not one devoid of risk, as both local and systemic adverse reactions may occur, especially in the initial phases. We compared the tolerance to 3 VIT buildup protocols and analyzed risk factors associated with adverse reactions during this phase. We enrolled 165 patients divided into 3 groups based on the buildup protocol used (3, 4, and 9 weeks). The severity of systemic reactions was evaluated according to the World Allergy Organization model. Results were analyzed using exploratory descriptive statistics, and variables were compared using analysis of variance. Adverse reactions were recorded in 53 patients (32%) (43 local and 10 systemic). Local reactions were immediate in 27 patients (63%) and delayed in 16 (37%). The severity of the local reaction was slight/moderate in 15 patients and severe in 13. Systemic reactions were grade 1-2. No significant association was found between the treatment modality and the onset of local or systemic adverse reactions or the type of local reaction. We only found a statistically significant association between severity of the local reaction and female gender. As for the risk factors associated with systemic reactions during the buildup phase, we found no significant differences in values depending on the protocol used or the insect responsible. The buildup protocols compared proved to be safe and did not differ significantly from one another. In the population studied, patients undergoing the 9-week schedule presented no systemic reactions. Therefore, this protocol can be considered the safest approach.

  14. Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters.

    PubMed

    Giménez, Beatriz; Pradíes, Guillermo; Martínez-Rus, Francisco; Özcan, Mutlu

    2015-01-01

    To evaluate the accuracy of two digital impression systems based on the same technology but different postprocessing correction modes of customized software, with consideration of several clinical parameters. A maxillary master model with six implants located in the second molar, second premolar, and lateral incisor positions was fitted with six cylindrical scan bodies. Scan bodies were placed at different angulations or depths apical to the gingiva. Two experienced and two inexperienced operators performed scans with either 3D Progress (MHT) or ZFX Intrascan (Zimmer Dental). Five different distances between implants (scan bodies) were measured, yielding five data points per impression and 100 per impression system. Measurements made with a high-accuracy three-dimensional coordinate measuring machine (CMM) of the master model acted as the true values. The values obtained from the digital impressions were subtracted from the CMM values to identify the deviations. The differences between experienced and inexperienced operators and implant angulation and depth were compared statistically. Experience of the operator, implant angulation, and implant depth were not associated with significant differences in deviation from the true values with both 3D Progress and ZFX Intrascan. Accuracy in the first scanned quadrant was significantly better with 3D Progress, but ZFX Intrascan presented better accuracy in the full arch. Neither of the two systems tested would be suitable for digital impression of multiple-implant prostheses. Because of the errors, further development of both systems is required.

  15. A Reflection on the Fate of Chiral 1,2,4-Triazole Fungicides in Biological Systems

    EPA Science Inventory

    In biological systems, stereoisomers of chiral compounds can exhibit significantly different pharmacokinetics (absorption, distribution, metabolism, and elimination) and pharmacodynamics (physiological effects). Pharmacokinetic processes (i.e., what the body does to the chemical)...

  16. Canal Aberration Assessment in Simulated Root Canals: a Comparative Study

    PubMed Central

    Jakupovic, Selma; Konjhodzic, Alma; Brankovic, Lajla Hasic; Korac, Samra; Tahmiscija, Irmina; Dzankovic, Aida; Glamoc, Alma Gavranovic

    2017-01-01

    Aim: The aim of this study was to compare time of preparation and canal aberrations in a simulated root canals after using three different rotary systems: Endostar E5, Endostar E3 and T One File Gold. Materials and Methods: A total of 90 endodontic training blocks were used in this study and divided into three groups consisting of 30 each (n = 30). Blocks processing was performed by thirty dentists without any prior experience in rotary instrumentation techniques. In the first group blocks were prepared using Endostar E5, in second one with Endostar E3 and in third one with T One File Gold system. The preparation time was measured. The postoperative image of each block was taken by stereomicroscope and canal aberrations (ledge and instrument fracture) was recorded. Statistical analysis was done by SPSS software. Results: Instrumentation with T One File Gold system is significantly faster compared to instrumentation with Endostar E5 and Endostar E3 systems (p <0.05). There are no statistically significant differences in the type and number of procedural errors between Endostar E5, Endostar E3 and T One File Gold systems when the operators have no previous experience in rotary instrumentation techniques. Conclusion: Under the conditions of this study, the incidence of examined canal aberrations were similar for all tested systems. The preparation time was significantly shorter with single file system. PMID:28974834

  17. Bacterial contamination along implant-abutment interface in external and internal-hex dental implants

    PubMed Central

    de Oliveira, Greison Rabelo; Olate, Sergio; Pozzer, Leandro; Cavalieri-Pereira, Lucas; Rodrigues-Chessa, Jaime G; Albergaría-Barbosa, José Ricardo

    2014-01-01

    The aim of this research was to evaluate bacterial contamination along the implant-abutment interface in relation to the size of the interface. 80 brand name implants were used, 40 internal-hex and 40 external-hex. The implants were handled in a sterile atmosphere inside a box, where they were inoculated with 0.3 μl of the Streptococcus sanguis ATCC10556 bacterium in the interior and the abutment was immediately installed with a torque of 30 Ncm for the external-hex and 20 Ncm for the internal-hex; the system was included in an Eppendorf control for 30 seconds and then placed in an Eppendorf control for 30 days. The implants were removed and assessed under a scanning electron microscope while the Eppendorf controls were bred in blood agar to analyze the colonies formed. The data were analyzed using the Chi-squared, Kruskal-Wallis and Mann-Whitney tests, considering a value of p<0.05 to obtain statistical significance. Five implants were excluded due to probable external contamination. Microspaces of up to 86.8 μm were observed in the external-hex implants and up to 53.9 μm in the internal-hex implants with no significant differences between the different systems being observed (p>0.05). The contamination observed was produced mainly in the external-hex implants and statistically significant differences were observed between the different hex systems from the same company. No significant differences were observed between interface size and bacterial contamination. Within our limitations, there was no relation between the size of the implant-abutment interface and bacterial contamination with Streptococcus sanguis ATCC10556. PMID:24753751

  18. Effects of aquaculture production noise on hearing, growth, and disease resistance of rainbow trout Oncorhynchus mykiss

    USGS Publications Warehouse

    Wysocki, L.E.; Davidson, J. W.; Smith, M.E.; Frankel, A.S.; Ellison, W.T.; Mazik, P.M.; Popper, A.N.; Bebak, J.

    2007-01-01

    Intensive aquaculture production often utilizes equipment (e.g., aerators, air and water pumps, harvesters, blowers, filtration systems, and maintenance machinery) that increases noise levels in fish culture tanks. Consequently, chronic exposure to elevated noise levels in tanks could negatively impact cultured species. Possible effects include impairment of the auditory system, increased stress, and reduced growth rates. The objective of this study was to evaluate the long-term effects of sound exposure on the hearing sensitivity, growth, and survival of cultured rainbow trout (Oncorhynchus mykiss). Two cohorts of rainbow trout were cultured for 8??months in replicated tanks consisting of three sound treatments: 115, 130, or 150 decibels referenced at 1 micropascal (dB re 1????Pa root mean square [RMS]) levels. Auditory evoked potential (AEP) recordings revealed no significant differences in hearing thresholds resulting from exposure to increased ambient sound levels. Although there was no evident noise-induced hearing loss, there were significant differences in hearing thresholds between the two fish cohorts examined. No statistical effect of sound treatment was found for growth rate and mortality within each fish cohort. There was no significant difference in mortality between sound treatments when fish were exposed to the pathogen Yersinia ruckeri, but there was significantly different mortality between cohorts. This study indicated that rainbow trout hearing sensitivity, growth, survival, stress, and disease susceptibility were not negatively impacted by noise levels common to recirculating aquaculture systems. These findings should not be generalized to all cultured fish species, however, because many species, including catfish and cyprinids, have much greater hearing sensitivity than rainbow trout and could be affected differently by noise. ?? 2007 Elsevier B.V. All rights reserved.

  19. Marginal and Internal Adaptation of Zirconia Crowns: A Comparative Study of Assessment Methods.

    PubMed

    Cunali, Rafael Schlögel; Saab, Rafaella Caramori; Correr, Gisele Maria; Cunha, Leonardo Fernandes da; Ornaghi, Bárbara Pick; Ritter, André V; Gonzaga, Carla Castiglia

    2017-01-01

    Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (a=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.

  20. The Effect of Artificial Aging on The Bond Strength of Heat-activated Acrylic Resin to Surface-treated Nickel-chromium-beryllium Alloy.

    PubMed

    Al Jabbari, Youssef S; Zinelis, Spiros; Al Taweel, Sara M; Nagy, William W

    2016-01-01

    The debonding load of heat-activated polymethylmethacrylate (PMMA) denture base resin material to a nickel-chromium-beryllium (Ni-Cr-Be) alloy conditioned by three different surface treatments and utilizing two different commercial bonding systems was investigated. Denture resin (Lucitone-199) was bonded to Ni-Cr-Be alloy specimens treated with Metal Primer II, the Rocatec system with opaquer and the Rocatec system without opaquer. Denture base resin specimens bonded to non-treated sandblasted Ni-Cr-Be alloy were used as controls. Twenty samples for each treatment condition (80 specimens) were tested. The 80 specimens were divided into two categories, thermocycled and non-thermocycled, containing four groups of ten specimens each. The non-thermocycled specimens were tested after 48 hours' storage in room temperature water. The thermocycled specimens were tested after 2,000 cycles in 4°C and 55°C water baths. The debonding load was calculated in Newtons (N), and collected data were subjected by non parametric test Kruskal-Wallis One Way Analysis of Variance on Ranks and Dunn's post hoc test at the α = 0.05. The Metal Primer II and Rocatec system without opaquer groups produced significantly higher bond strengths (119.9 and 67.6 N), respectively, than did the sandblasted and Rocatec system with opaquer groups, where the bond strengths were 2.6 N and 0 N, respectively. The Metal Primer II was significantly different from all other groups (P<0.05). The bond strengths of all groups were significantly decreased (P<0.05) after thermocycling. Although thermocycling had a detrimental effect on the debonding load of all surface treatments tested, the Metal Primer II system provided higher values among all bonding systems tested, before and after thermocycling.

  1. Movement control during aspiration with different injection systems via video monitoring-an in vitro model.

    PubMed

    Kämmerer, P W; Schneider, D; Pacyna, A A; Daubländer, M

    2017-01-01

    The aim of the present study was an evaluation of movement during double aspiration by different manual syringes and one computer-controlled local anesthesia delivery system (C-CLAD). With five different devices (two disposable syringes (2, 5 ml), two aspirating syringes (active, passive), one C-CLAD), simulation of double aspiration in a phantom model was conducted. Two experienced and two inexperienced test persons carried out double aspiration with the injection systems at the right and left phantom mandibles in three different inclination angles (n = 24 × 5 × 2 for each system). 3D divergences of the needle between aspiration procedures (mm) were measured with two video cameras. An average movement for the 2-ml disposal syringe of 2.85 mm (SD 1.63), for the 5 ml syringe of 2.36 mm (SD 0.86), for the active-aspirating syringe of 2.45 mm (SD 0.9), for the passive-aspirating syringe of 2.01 mm (SD 0.7), and for the C-CLAD, an average movement of 0.91 mm (SD 0.63) was seen. The movement was significantly less for the C-CLAD compared to the other systems (p < 0.001). The movement of the needle in the soft tissue was significantly less for the C-CLAD compared to the other systems (p < 0.001). A difference in involuntary movement of the syringe could be seen in comparison between manual and C-CLAD systems. Launching the aspiration by a foot pedal in computer-assisted anesthesia leads to a minor movement. To solve the problem of movement during aspiration with possibly increased false-negative results, a C-CLAD seems to be favorable.

  2. Danger zone analysis using cone beam computed tomography after apical enlargement with K3 and K3XF in a manikin model

    PubMed Central

    Olivier, Juan-Gonzalo; García-Font, Marc; Gonzalez-Sanchez, Jose-Antonio; Roig-Cayon, Miguel

    2016-01-01

    Background The objective of the study was to evaluate and compare how apical enlargement with K3 and K3XF nickel-titanium (NiTi) rotary instruments reduces the root thickness in the danger zone and affects canal transportation and centering ability in mandibular molar mesial canals in a manikin extracted tooth model. Material and Methods Seventy-two mesial root canals of first mandibular molars were instrumented. Initial and post-instrumentation Cone Beam Computed Tomography scans were performed after root canal preparation up to size 25, 30, 35 and 40 files. Canal transportation, canal centering and remaining root dentin thickness toward the danger zone were calculated in sections 1, 2 and 3 mm under the furcation level. Data were analyzed using non-parametric Kruskal-Wallis analysis of variance at a significance level of P < 0.05. Results K3 instruments removed more dentin toward the danger zone compared with K3XF instruments (P< .05) and significant differences in dentin thickness were found when canal enlargement was performed to a #35-40 with both systems (P< 0.05). No significant differences in canal transportation and centering ability were found between systems, except when canal enlargement was performed to a #40 (P = 0,0136). No differences were observed when comparing the number of uses in both systems (P> 0.05). Conclusions Under the conditions of this study K3 removed a significant amount of dentin at the furcation level compared with the R-Phase K3XF rotary system in curved root canals. Enlargement to a 35-40/04 file removed significantly more dentin with both systems. Key words:K3, K3XF, R-phase, center ability, canal transportation, dentin thickness, increased apical enlargement, danger zone, dentin thickness. PMID:27703602

  3. Systemic lupus erythematosus patients in the low-latitude plateau of China: altitudinal influences.

    PubMed

    Qian, G; Ran, X; Zhou, C X; Deng, D Q; Zhang, P L; Guo, Y; Luo, J H; Zhou, X H; Xie, H; Cai, M

    2014-12-01

    The current study was to investigate the features of hospitalized patients with systemic lupus erythematosus (SLE) at different altitudes. The correlation between SLE activity and altitudinal variations was also explored. Medical records of 1029 patients were retrospectively reviewed. Activity of SLE in each organ system was recorded using the Systemic Lupus Erythematosus Disease Activity Index (SLEDAI). There was no significant correlation between SLE activity and altitudes (r = 0.003, p = 0.159). Age at onset for SLE patients at high altitudes was significantly younger than that at low and moderate altitudes (p = 0.022 and p = 0.004, respectively). Age at SLE admission at low altitudes was significant older than those at moderate and high altitudes (p = 0.011 and p < 0.001, respectively). Patients at high altitudes had shorter duration from disease onset to admission than those at moderate altitudes (p = 0.009). Incidence of Sm antibodies-positive for resident patients at high altitudes was 36.4%, which were higher than that at moderate altitudes (p = 0.003). We found increasing trends of CNS activity in active patients; immunological and renal activities in inactive patients were correlated with elevated altitudes (p = 0.024, p = 0.004, p = 0.005), while arthritis scores in active patients showed the tendency of decreasing with the rise of elevation (p = 0.002). Hemoglobin level, red blood cell and platelet counts at high altitudes were significantly lower than those at low altitudes (p < 0.05, respectively). There was no significant difference in hemoglobin level between moderate- and low-altitude groups (p > 0.05). No significant difference in platelet counts between moderate- and high-altitude groups was observed (p > 0.05). Our findings suggest that some clinical features, laboratory tests and activity of main organs in SLE are influenced by altitudes. Furthermore, organ activities of active and inactive SLE patients have different patterns of altitudinal variations. These distinctive variations likely reveal that peculiar environmental factors at high altitudes can affect the development of SLE. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Sealing ability and bond strength of four contemporary adhesives to enamel and to dentine.

    PubMed

    Atash, R; Vanden Abbeele, A

    2005-12-01

    To compare the shear bond strength and microleakage of four adhesive systems to the enamel and dentine of primary bovine teeth. 120 bovine primary mandibular incisors were collected and stored in an aqueous 1% chloramine solution at room temperature for no longer than 3 months after extraction (80 for shear bond testing and 40 for microleakage evaluation). The adhesives tested were Clearfil SE bond (SE), Adper Prompt L Pop (LP), Xeno III (XE), and Prime and Bond NT (PB). For shear bond strength testing the specimens were wet ground to 600 grit SiC paper to expose a flat enamel or dentine surface. After bonding and restoration with Dyract AP (DAP), the teeth were subjected to shear stress using a universal testing machine. For microleakage evaluation, facial class V cavities were prepared half in enamel and half in cementum. All cavities were restored with DAP. After thermocycling and immersion in 2% methylene blue, the dye penetration was evaluated under a stereomicroscope. All data were analysed by Chi-square tests or Fisher's tests when adapted in order to determine the significant differences between groups. Results were considered as significant for p < 0.05. Results were analysed with an ANOVA test and a Bonferroni's multiple comparison. The level of significance was p < 0.05. Shear bond strength values (MPa,) ranged from: on enamel 11.06 to 5.34, in decreasing order SE, LP, XE and PB and on dentine 10.47 to 4.74, in decreasing order SE, XE, LP and PB. Differences in bond strengths between the four systems on enamel and dentine were all statistically significant, excepted for XE vs LP (shear bond at dentine). No significant differences were recorded in the microleakage degree between the four adhesive systems on enamel and on dentine (p > 0.0.5). The highest shear bond strength was achieved by Clearfil SE bond and the lowest by Prime and Bond NT. There was no significant difference concerning the sealing ability of the four adhesive systems.

  5. Sex differences of gray matter morphology in cortico-limbic-striatal neural system in major depressive disorder.

    PubMed

    Kong, Lingtao; Chen, Kaiyuan; Womer, Fay; Jiang, Wenyan; Luo, Xingguang; Driesen, Naomi; Liu, Jie; Blumberg, Hilary; Tang, Yanqing; Xu, Ke; Wang, Fei

    2013-06-01

    Sex differences are observed in both epidemiological and clinical aspects of major depressive disorder (MDD). The cortico-limbic-striatal neural system, including the prefrontal cortex, amygdala, hippocampus, and striatum, have shown sexually dimorphic morphological features and have been implicated in the dysfunctional regulation of mood and emotion in MDD. In this study, we utilized a whole-brain, voxel-based approach to examine sex differences in the regional distribution of gray matter (GM) morphological abnormalities in medication-naïve participants with MDD. Participants included 29 medication-naïve individuals with MDD (16 females and 13 males) and 33 healthy controls (HC) (17 females and 16 males). Gray matter morphology of the cortico-limbic-striatal neural system was examined using voxel-based morphometry analyzes of high-resolution structural magnetic resonance imaging scans. The main effect of diagnosis and interaction effect of diagnosis by sex on GM morphology were statistically significant (p < 0.05, corrected) in the left ventral prefrontal cortex, right amygdala, right hippocampus and bilateral caudate when comparing the MDD and HC groups. Posthoc analyzes showed that females with MDD had significant GM decreases in limbic regions (p < 0.05, corrected), compared to female HC; while males with MDD demonstrated significant GM reduction in striatal regions, (p < 0.05, corrected), compared to HC males. The observed sex-related patterns of abnormalities within the cortico-limbic-strial neural system, such as predominant prefrontal-limbic abnormalities in MDD females vs. predominant prefrontal-striatal abnormalities in MDD males, suggest differences in neural circuitry that may mediate sex differences in the clinical presentation of MDD and potential targets for sex-differentiated treatment of the disorder. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.

    PubMed

    Quek, H C; Tan, Keson B; Nicholls, Jack I

    2008-01-01

    Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level recommended by the manufacturer.

  7. Improving esthetic results in benign parotid surgery: statistical evaluation of facelift approach, sternocleidomastoid flap, and superficial musculoaponeurotic system flap application.

    PubMed

    Bianchi, Bernardo; Ferri, Andrea; Ferrari, Silvano; Copelli, Chiara; Sesenna, Enrico

    2011-04-01

    The purpose of this article was to analyze the efficacy of facelift incision, sternocleidomastoid muscle flap, and superficial musculoaponeurotic system flap for improving the esthetic results in patients undergoing partial parotidectomy for benign parotid tumor resection. The usefulness of partial parotidectomy is discussed, and a statistical evaluation of the esthetic results was performed. From January 1, 1996, to January 1, 2007, 274 patients treated for benign parotid tumors were studied. Of these, 172 underwent partial parotidectomy. The 172 patients were divided into 4 groups: partial parotidectomy with classic or modified Blair incision without reconstruction (group 1), partial parotidectomy with facelift incision and without reconstruction (group 2), partial parotidectomy with facelift incision associated with sternocleidomastoid muscle flap (group 3), and partial parotidectomy with facelift incision associated with superficial musculoaponeurotic system flap (group 4). Patients were considered, after a follow-up of at least 18 months, for functional and esthetic evaluation. The functional outcome was assessed considering the facial nerve function, Frey syndrome, and recurrence. The esthetic evaluation was performed by inviting the patients and a blind panel of 1 surgeon and 2 secretaries of the department to give a score of 1 to 10 to assess the final cosmetic outcome. The statistical analysis was finally performed using the Mann-Whitney U test for nonparametric data to compare the different group results. P less than .05 was considered significant. No recurrence developed in any of the 4 groups or in any of the 274 patients during the follow-up period. The statistical analysis, comparing group 1 and the other groups, revealed a highly significant statistical difference (P < .0001) for all groups. Also, when group 2 was compared with groups 3 and 4, the difference was highly significantly different statistically (P = .0018 for group 3 and P = .0005 for group 4). Finally, when groups 3 and 4 were compared, the difference was not statistically significant (P = .3467). Partial parotidectomy is the real key point for improving esthetic results in benign parotid surgery. The evaluation of functional complications and the recurrence rate in this series of patients has confirmed that this technique can be safely used for parotid benign tumor resection. The use of a facelift incision alone led to a high statistically significant improvement in the esthetic outcome. When the facelift incision was used with reconstructive techniques, such as the sternocleidomastoid muscle flap or the superficial musculoaponeurotic system flap, the esthetic results improved further. Finally, no statistically significant difference resulted comparing the use of the superficial musculoaponeurotic system and the sternocleidomastoid muscle flap. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. The 8th edition of the American Joint Committee on Cancer tumor-node-metastasis staging system for gastric cancer is superior to the 7th edition: results from a Chinese mono-institutional study of 1663 patients.

    PubMed

    Ji, Xin; Bu, Zhao-De; Yan, Yan; Li, Zi-Yu; Wu, Ai-Wen; Zhang, Lian-Hai; Zhang, Ji; Wu, Xiao-Jiang; Zong, Xiang-Long; Li, Shuang-Xi; Shan, Fei; Jia, Zi-Yu; Ji, Jia-Fu

    2017-11-22

    We investigated the superiority of the 8th edition of the tumor-node-metastasis (TNM) system for patients in China with gastric cancer. The survival outcomes of 1663 patients with gastric cancer undergoing radical resection were analyzed. In the 8th edition system, homogeneous 5-year survival rates among different pathological TNM (pTNM) categories belonging to the same stage were observed. However, in the 7th edition system, the differences of 5-year survival rate among pTNM categories belonging to the same stage were observed in stages IIB (P = 0.010), IIIB (P = 0.004), and IIIC (P < 0.001). For patients in the pT1-3 (P < 0.001) and pT4a (P < 0.001) categories, there were significant differences in survival between patients in the pN3a and pN3b categories. Furthermore, partial cases (pT4bN0M0/T4aN2M0) of stage IIIB were downstaged to stage IIIA in the 8th edition system, and the 5-year survival rate of these patients was significantly better than that of patients in stage IIIB in the 8th edition system. Similarly, the 5-year survival rate of patients in p4bN2M0/T4aN3aM0 downstaged from stage IIIC to IIIB was significantly better than that of patients in stage IIIC. Compared with the 7th edition system, the 8th edition system had a higher likelihood ratio and linear trend chi-squared score and a smaller Akaike information criteria value. The 8th edition system is superior to the 7th edition system in terms of homogeneity, discriminatory ability, and monotonicity of gradients for Chinese patients with gastric cancer.

  9. On creating macroscopically identical granular systems with different numbers of particles

    NASA Astrophysics Data System (ADS)

    van der Meer, Devaraj; Rivas, Nicolas

    2015-11-01

    One of the fundamental differences between granular and molecular hydrodynamics is the enormous difference in the total number of constituents. The small number of particles implies that the role of fluctuations in granular dynamics is of paramount importance. To obtain more insight in these fluctuations, we investigate to what extent it is possible to create identical granular hydrodynamic states with different number of particles. A definition is given of macroscopically equivalent systems, and the dependency of the conservation equations on the particle size is studied. We show that, in certain cases, and by appropriately scaling the microscopic variables, we are able to compare systems with significantly different number of particles that present the same macroscopic phenomenology. We apply these scalings in simulations of a vertically vibrated system, namely the density inverted granular Leidenfrost state and its transition to a buoyancy-driven convective state.

  10. Is Student Performance on the Information Systems Analyst Certification Exam Affected by Form of Delivery of Information Systems Coursework?

    ERIC Educational Resources Information Center

    Haga, Wayne; Moreno, Abel; Segall, Mark

    2012-01-01

    In this paper, we compare the performance of Computer Information Systems (CIS) majors on the Information Systems Analyst (ISA) Certification Exam. The impact that the form of delivery of information systems coursework may have on the exam score is studied. Using a sample that spans three years, we test for significant differences between scores…

  11. Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi systems.

    PubMed

    Benetz, B A; Diaconu, E; Bowlin, S J; Oak, S S; Laing, R A; Lass, J H

    1999-01-01

    Compare corneal endothelial image analysis by Konan SP8000 and Bio-Optics Bambi image-analysis systems. Corneal endothelial images from 98 individuals (191 eyes), ranging in age from 4 to 87 years, with a normal slit-lamp examination and no history of ocular trauma, intraocular surgery, or intraocular inflammation were obtained by the Konan SP8000 noncontact specular microscope. One observer analyzed these images by using the Konan system and a second observer by using the Bio-Optics Bambi system. Three methods of analyses were used: a fixed-frame method to obtain cell density (for both Konan and Bio-Optics Bambi) and a "dot" (Konan) or "corners" (Bio-Optics Bambi) method to determine morphometric parameters. The cell density determined by the Konan fixed-frame method was significantly higher (157 cells/mm2) than the Bio-Optics Bambi fixed-frame method determination (p<0.0001). However, the difference in cell density, although still statistically significant, was smaller and reversed comparing the Konan fixed-frame method with both Konan dot and Bio-Optics Bambi comers method (-74 cells/mm2, p<0.0001; -55 cells/mm2, p<0.0001, respectively). Small but statistically significant morphometric analyses differences between Konan and Bio-Optics Bambi were seen: cell density, +19 cells/mm2 (p = 0.03); cell area, -3.0 microm2 (p = 0.008); and coefficient of variation, +1.0 (p = 0.003). There was no statistically significant difference between these two methods in the percentage of six-sided cells detected (p = 0.55). Cell densities measured by the Konan fixed-frame method were comparable with Konan and Bio-Optics Bambi's morphometric analysis, but not with the Bio-Optics Bambi fixed-frame method. The two morphometric analyses were comparable with minimal or no differences for the parameters that were studied. The Konan SP8000 endothelial image-analysis system may be useful for large-scale clinical trials determining cell loss; its noncontact system has many clinical benefits (including patient comfort, safety, ease of use, and short procedure time) and provides reliable cell-density calculations.

  12. Effects of fermented milk treatment on microbial population and metabolomic outcomes in a three-stage semi-continuous culture system.

    PubMed

    Cha, Kwang Hyun; Lee, Eun Ha; Yoon, Hyo Shin; Lee, Jae Ho; Kim, Joo Yun; Kang, Kyungsu; Park, Jin-Soo; Jin, Jong Beom; Ko, GwangPyo; Pan, Cheol-Ho

    2018-10-15

    We investigated the impact of a fermented milk product on gut microbiota and their metabolism in 3 different conditions of the colon with a systemic viewpoint. An in vitro semi-continuous anaerobic cultivation was used to assess the colon compartment-specific influence of fermented milk, followed by a multiomics approach combining 16S rDNA amplicon sequencing and nuclear magnetic resonance (NMR) spectroscopy. The microbiome profiling and metabolomic features were significantly different across three colon compartments and after fermented milk treatment. Integrative correlation analysis indicated that the alteration of butyrate-producing microbiota (Veillonella, Roseburia, Lachnospira, and Coprococcus) and some primary metabolites (butyrate, ethanol, lactate, and isobutyrate) in the treatment group had a strong association with the fermented milk microorganisms. Our findings suggested that fermented milk treatment significantly affected microbial population in an in vitro cultivation system as well as the colonic metabolome in different ways in each of colon compartment. Copyright © 2018. Published by Elsevier Ltd.

  13. What is adapted in face adaptation? The neural representations of expression in the human visual system.

    PubMed

    Fox, Christopher J; Barton, Jason J S

    2007-01-05

    The neural representation of facial expression within the human visual system is not well defined. Using an adaptation paradigm, we examined aftereffects on expression perception produced by various stimuli. Adapting to a face, which was used to create morphs between two expressions, substantially biased expression perception within the morphed faces away from the adapting expression. This adaptation was not based on low-level image properties, as a different image of the same person displaying that expression produced equally robust aftereffects. Smaller but significant aftereffects were generated by images of different individuals, irrespective of gender. Non-face visual, auditory, or verbal representations of emotion did not generate significant aftereffects. These results suggest that adaptation affects at least two neural representations of expression: one specific to the individual (not the image), and one that represents expression across different facial identities. The identity-independent aftereffect suggests the existence of a 'visual semantic' for facial expression in the human visual system.

  14. Analysis and experimental study of wireless power transfer with HTS coil and copper coil as the intermediate resonators system

    NASA Astrophysics Data System (ADS)

    Wang, Xiufang; Nie, Xinyi; Liang, Yilang; Lu, Falong; Yan, Zhongming; Wang, Yu

    2017-01-01

    Intermediate resonator (repeater) between transmitter and receiver can significantly increase the distance of wireless power transfer (WPT) and the efficiency of wireless power transfer. The wireless power transfer via strongly coupled magnetic resonances with an high temperature superconducting (HTS) coil and copper coil as intermediate resonators was presented in this paper. The electromagnetic experiment system under different conditions with different repeating coils were simulated by finite element software. The spatial distribution patterns of magnetic induction intensity at different distances were plotted. In this paper, we examined transfer characteristics with HTS repeating coil and copper repeating coil at 77 K and 300 K, respectively. Simulation and experimental results show that HTS and copper repeating coil can effectively enhance the space magnetic induction intensity, which has significant effect on improving the transmission efficiency and lengthening transmission distance. We found that the efficiency and the distance of wireless power transfer system with an HTS coil as repeater is much higher by using of copper coil as repeater.

  15. Bacterial composition in a metropolitan drinking water distribution system utilizing different source waters.

    PubMed

    Gomez-Alvarez, Vicente; Humrighouse, Ben W; Revetta, Randy P; Santo Domingo, Jorge W

    2015-03-01

    We investigated the bacterial composition of water samples from two service areas within a drinking water distribution system (DWDS), each associated with a different primary source of water (groundwater, GW; surface water, SW) and different treatment process. Community analysis based on 16S rRNA gene clone libraries indicated that Actinobacteria (Mycobacterium spp.) and α-Proteobacteria represented nearly 43 and 38% of the total sequences, respectively. Sequences closely related to Legionella, Pseudomonas, and Vibrio spp. were also identified. In spite of the high number of sequences (71%) shared in both areas, multivariable analysis revealed significant differences between the GW and SW areas. While the dominant phylotypes where not significantly contributing in the ordination of samples, the populations associated with the core of phylotypes (1-10% in each sample) significantly contributed to the differences between both service areas. Diversity indices indicate that the microbial community inhabiting the SW area is more diverse and contains more distantly related species coexisting with local assemblages as compared with the GW area. The bacterial community structure of SW and GW service areas were dissimilar, suggesting that their respective source water and/or water quality parameters shaped by the treatment processes may contribute to the differences in community structure observed.

  16. Bilateral Symmetry before and Six Months after Aberration-Free™ Correction with the SCHWIND AMARIS TotalTech Laser: Clinical Outcomes

    PubMed Central

    Arbelaez, Maria Clara; Vidal, Camila; Arba-Mosquera, Samuel

    2010-01-01

    Purpose To compare the preoperative and postoperative bilateral symmetry between OD and OS eyes that have undergone femto-LASIK using the Ziemer LDV femtosecond laser system, the SCHWIND AMARIS Excimer Laser and the Aberrationfree™ profiles implemented in the SCHWIND Custom Ablation Manager software. Methods A total of 25 LASIK patients were bilaterally evaluated at the six-month follow-up visit. In all cases standard examinations, pre- and postoperative analysis with corneal wavefront topography (OPTIKON Scout) were performed. Aberration-free™ aspheric treatments were devised using the Custom Ablation Manager software and ablations were performed by means of the SCHWIND AMARIS flying-spot excimer laser system (both SCHWIND eyetech- solutions). In all cases LASIK flaps were created using an LDV femtosecond laser (Ziemer Group). The OD/OS bilateral symmetry was evaluated in terms of corneal wavefront aberration. Results Preoperatively, 11 Zernike terms showed significant bilateral (OS-vs.-OD) symmetry, and only 6 Zernike terms were significantly different. Overall, 23 out of the 25 patients showed significant bilateral symmetry, and only 2 out of 25 patients showed significant differences. None of the aberration metrics changed from pre- to postoperative values by a clinically relevant amount. At the 6-month postoperative visit, 12 Zernike terms showed significant symmetry, and 8 terms were significantly different. Overall, 22 out of 25 patients showed significant bilateral symmetry (OS vs. OD), and only 3 out of 25 patients showed significant differences. Also, this postoperative examination revealed that 6 Zernike terms lost significant OS-vs.-OD symmetry, but 4 Zernike terms gained significant symmetry. Finally, 4 patients lost significant bilaterality, and 2 patients gained significant bilaterality: bilateral symmetry between eyes was better maintained in those patients with a clear preoperative bilateral symmetry. Conclusions Aberration-Free Treatments with the SCHWIND AMARIS did not induce clinically significant aberrations, maintained the global OD-vs.-OS bilateral symmetry, as well as the bilateral symmetry between corresponding Zernike terms (which influences binocular summation).

  17. Transient Classifier Systems and Man-Machine Interface Research.

    DTIC Science & Technology

    1987-08-31

    different timbre from two different resonant sources, i.e., like a violin and oboe emitting nearly the same fundamental mode fre- quency, but each with its...the subjects by examing both hits and misses for signal and noise stimuli. A pairwise com- parison of the means resulted in significant differences (at

  18. Two Different Percutaneous Bone-Anchored Hearing Aid Abutment Systems: Comparative Clinical Study.

    PubMed

    Polat, Beldan; İşeri, Mete; Orhan, Kadir Serkan; Yılmazer, Ayça Başkadem; Enver, Necati; Ceylan, Didem; Kara, Ahmet; Güldiken, Yahya; Çomoğlu, Şenol

    2016-04-01

    To compare two different percutaneous bone-anchored hearing aid (BAHA) abutment systems regarding operation time, scar healing, quality of life, implant stability, audiologic results, and complications. The study involves a prospective multi-center clinical evaluation. Thirty-two consecutive patients who had undergone BAHA surgery from January 2011 to January 2013 in two tertiary centers were included in the study. The Glasgow Inventory Benefit Score was used to assess the patients at least 6 months after surgery. The operation time and complications were recorded. Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Holger's classification was used to evaluate skin reactions. The mean length of the operation was 39.2±4 min for standard abutment and 18.3±5.7 min for hydroxyapatite-coated abutment. ISQ scores were significantly better for standard abutment in all tests. The mean total Glasgow Inventory Benefit Score was 39.3±19 for the standard abutment and 46.3±24.5 for the hydroxyapatite-coated abutment groups, but there was no statistical significance between the two groups. There was no difference in audiological improvement between the two groups after surgery. Hydroxyapatite-coated abutment provided a shorter operation time that was significantly different from standard abutment. There were no significant differences between standard abutment and hydroxyapatite-coated abutment regarding audiologic improvement, quality of life, loading time, and complications.

  19. Transmittance of MCF-7 breast tumor cell line through visible and near infrared spectrum

    NASA Astrophysics Data System (ADS)

    Tabakoǧlu, H. Ã.-zgür

    2016-03-01

    In this study, light transmittance of MCF-7 tumor cells from 450 nm to 1100 nm has been measured in their growing medium and evaluated. Transmittance differences have been tried to be put forward in cancer cell line on visible (VIS) and near infrared (NIR) spectrum as well as in between different numbers of cells in medium. An absorption-reflection spectrophotometer was used in the experiments. System has a tungsten light source, optical chopper, a monochromator, sample chamber, silicon detectors, lock-in amplifier and computer. System was controlled by software in order to adjust scan range, scan steps and grating configuration. Cells were grown in medium, and measurements were taken from cells while they were in 5 ml medium. According to our findings, there are significant differences between VIS and NIR regions for the same number of cells. There were found no statistical difference among different numbers of cells. Increasing number of cells has not affected the transmittance. Transmittance of medium is not significantly different from different concentration of cells.

  20. Three-dimensional accuracy of plastic transfer impression copings for three implant systems.

    PubMed

    Teo, Juin Wei; Tan, Keson B; Nicholls, Jack I; Wong, Keng Mun; Uy, Joanne

    2014-01-01

    The purpose of this study was to compare the three-dimensional accuracy of indirect plastic impression copings and direct implant-level impression copings from three implant systems (Nobel Biocare [NB], Biomet 3i [3i], and Straumann [STR]) at three interimplant buccolingual angulations (0, 8, and 15 degrees). Two-implant master models were used to simulate a three-unit implant fixed partial denture. Test models were made from Impregum impressions using direct implant-level impression copings (DR). Abutments were then connected to the master models for impressions using the plastic impression copings (INDR) at three different angulations for a total of 18 test groups (n = 5 in each group). A coordinate measuring machine was used to measure linear distortions, three-dimensional (3D) distortions, angular distortions, and absolute angular distortions between the master and test models. Three-way analysis of variance showed that the implant system had a significant effect on 3D distortions and absolute angular distortions in the x- and y-axes. Interimplant angulation had a significant effect on 3D distortions and absolute angular distortions in the y-axis. Impression technique had a significant effect on absolute angular distortions in the y-axis. With DR, the NB and 3i systems were not significantly different. With INDR, 3i appeared to have less distortion than the other systems. Interimplant angulations did not significantly affect the accuracy of NBDR, 3iINDR, and STRINDR. The accuracy of INDR and DR was comparable at all interimplant angulations for 3i and STR. For NB, INDR was comparable to DR at 0 and 8 degrees but was less accurate at 15 degrees. Three-dimensional accuracy of implant impressions varied with implant system, interimplant angulation, and impression technique.

  1. The effectiveness of four-cavity treatment systems in sealing amalgam restorations.

    PubMed

    Morrow, Leean A; Wilson, Nairn H F

    2002-01-01

    Amalgam does not bond to tooth tissue; therefore, restorations using such material are prone to leakage despite the deposition of corrosion products. This study evaluated the effectiveness of four cavity treatment systems placed in vivo in sealing restorations of amalgam. Four cavity treatment systems were investigated in this study: Cervitec, Gluma One Bond, Panavia 21 and Copaliner Dentin Varnish and Sealant. No cavity treatment was placed in an additional group to serve as a control. The teeth were extracted within 15 minutes of restoration placement. The specimens were thermocycled (5-55 +/- 2 degrees C, 500 cycles), immersed in a dye solution, sectioned and scored for leakage. Scanning electron microscopy also examined features of the tooth/restoration interfaces. There were statistically significant differences among the groups regarding leakage scores (p = 0.00). None of the materials tested consistently prevented leakage; however, use of Copaliner Dentin Varnish and Sealant resulted in less overall, occlusal and cervical microleakage than any other systems tested. Significantly more leakage was observed in relation to the cervical portions of the cavities (p = 0.00). No significant differences were identified between the leakage scores obtained for the buccal and palatal (lingual) cavities and the different tooth types (p = 0.52 and 0.83, respectively). A level of significance of 0.05 was selected in all cases. The benefits of the materials tested in this study need to be evaluated using robust, long-term clinical studies. Further work should continue to develop laboratory tests that predict the behavior and performance of cavity sealants in clinical service.

  2. [Assessment of cardiovascular risk in population groups. Comparison of Score system and Framingham in hypertensive patients].

    PubMed

    Cosín Aguilar, J; Hernándiz Martínez, A; Rodríguez Padial, L; Zamorano Gómez, J L; Arístegui Urrestarazu, R; Armada Peláez, B; Aguilar Llopis, A; Masramon Morell, X

    2006-04-01

    Calculation of cardiovascular risk in populations allows for developing and assessing of intervention programs and adapting health resources. While the Framingham System has been used in the past, a group of European researchers have proposed a different method called the Score project. The purpose of this paper is to compare the value of both methods for assessing cardiovascular risk. In 6,775 evaluable hypertensive patients distributed over the 17 Spanish autonomous communities (ACs), the 10-year risk of experiencing a coronary event (CR) was calculated using the Framingham equation, while risk of coronary death (RCD) and vascular death (RVD) was calculated using the Score project system, both at baseline and after one year of blood pressure control with amlodipine at the required dose. A comparison was made of the capacity to detect risk differences by both methods between populations with known different risks, and in the same population as a result of blood pressure control. Both the Score and the Framingham systems detected the significant decrease in both CR and RCD or RVD at one year of application of the CORONARIA study protocol. Risk decrease measured by any of the two methods was significant (p < 0.05) overall, by genders, and by ACs. However, the Score System, unlike the Framingham system, could not detect the reported differences in the mortality risk for coronary and vascular disease between the ACs of the North and the South-East parts of Spain.

  3. Grayscale image segmentation for real-time traffic sign recognition: the hardware point of view

    NASA Astrophysics Data System (ADS)

    Cao, Tam P.; Deng, Guang; Elton, Darrell

    2009-02-01

    In this paper, we study several grayscale-based image segmentation methods for real-time road sign recognition applications on an FPGA hardware platform. The performance of different image segmentation algorithms in different lighting conditions are initially compared using PC simulation. Based on these results and analysis, suitable algorithms are implemented and tested on a real-time FPGA speed sign detection system. Experimental results show that the system using segmented images uses significantly less hardware resources on an FPGA while maintaining comparable system's performance. The system is capable of processing 60 live video frames per second.

  4. Testing Nelder-Mead based repulsion algorithms for multiple roots of nonlinear systems via a two-level factorial design of experiments.

    PubMed

    Ramadas, Gisela C V; Rocha, Ana Maria A C; Fernandes, Edite M G P

    2015-01-01

    This paper addresses the challenging task of computing multiple roots of a system of nonlinear equations. A repulsion algorithm that invokes the Nelder-Mead (N-M) local search method and uses a penalty-type merit function based on the error function, known as 'erf', is presented. In the N-M algorithm context, different strategies are proposed to enhance the quality of the solutions and improve the overall efficiency. The main goal of this paper is to use a two-level factorial design of experiments to analyze the statistical significance of the observed differences in selected performance criteria produced when testing different strategies in the N-M based repulsion algorithm. The main goal of this paper is to use a two-level factorial design of experiments to analyze the statistical significance of the observed differences in selected performance criteria produced when testing different strategies in the N-M based repulsion algorithm.

  5. Well Clear: General Aviation and Commercial Pilots' Perceptioin of Unmanned Aerial Vehicles in the National Airspace System

    NASA Technical Reports Server (NTRS)

    Ott, Joseph

    2015-01-01

    This research explored how different pilots perceived the concept of the Well Clear Boundary (WCB) and observed if that boundary changed when dealing with manned versus unmanned aircraft systems (UAS), and the effects of other variables. Pilots' WCB perceptions were collected objectively through simulator recordings and subjectively through questionnaires. Objectively, significant differences were found in WCB perception between two pilot types (general aviation [GA], and Airline Transport Pilots [ATPs]), and significant WCB differences were evident when comparing two intruder types (manned versus unmanned aircraft). Differences were dependent on other manipulated variables (intruder approach angle, ownship speed, and background traffic levels). Subjectively, there were differences in WCB perception across pilot types; GA pilots trusted UAS aircraft higher than the more experienced ATPs. Conclusions indicate pilots' WCB mental models are more easily perceived as time-based boundaries in front of ownship, and more easily perceived as distance-based boundaries to the rear of ownship.

  6. Effect of varying core thicknesses and artificial aging on the color difference of different all-ceramic materials.

    PubMed

    Dikicier, Sibel; Ayyildiz, Simel; Ozen, Julide; Sipahi, Cumhur

    2014-11-01

    Clinicians should reserve all-ceramics with high translucency for clinical applications in which high-level esthetics are required. Furthermore, it is unclear whether a correlation exists between core thickness and color change. The aim of this study was to examine the effects of different core thicknesses and artificial aging on the color stability of three all-ceramic systems. Ninety disc-shaped cores with different thicknesses (0.5 mm, 0.8 mm and 1.0 mm) were prepared from three all-ceramic systems, In-Ceram Alumina (IC), IPS e.max Press (EM) and Katana (K). The colors of the samples were measured with a spectrophotometer and the color parameters (L*, a*, b*, ΔE) were calculated according to the CIE L*a*b* (Commission Internationale de L'Eclairage) color system before and after aging. The effects of aging on color parameters were statistically significant (p < 0.001), regardless of core thickness. For all systems, the CIE a* values increased as the thickness of the core increased. Conversely, such increases in core porcelain thickness were correlated with decreasing CIE L* and b* values. Core thickness had a statistically significant effect on color change among the groups. Different core thicknesses (from 1.0-0.5 mm) and artificial aging affected color stability of the all-ceramic materials tested.

  7. Extensibility of the fission surface power (FSP) system from the moon to Mars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poston, David Irvin

    2011-01-28

    Fission reactors have great near-term potential to power human and robotic missions/outposts on the surface of the Moon and Mars (and potentially other planets, moons, and asteroids). The ability to provide a power-rich environment that is independent of solar intensity, nights, dust storms, etc., is of significant (perhaps enabling) importance to the further expansion of humans into our solar system. NASA's Reference Fission Surface Power (FSP) System is a 40 kWe system that has been primarily designed for lunar applications. This paper examines the extensibility of the FSP design and technology for potential missions on Mars. Possible impacts include themore » effects of changes in heat sink, gravity, day-night cycles, mission transit time, communication delay, and the chemistry of the regolith and atmosphere. One of the biggest impacts might be differences in the potential utilization of in-situ materials for shielding. Another major factor is that different missions will likely require different performance requirements, e.g. power, lifetime and mass. This paper concludes that the environmental differences between potential mission locations will not require significant changes in design and technologies, unless performance requirements for a specific mission are substantially different than those adopted for the FSP The primary basis for this conclusion is that the FSP has been designed with robust materials and design margins.« less

  8. Interruption as a test of the user-computer interface

    NASA Technical Reports Server (NTRS)

    Kreifeldt, J. G.; Mccarthy, M. E.

    1981-01-01

    In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.

  9. Interconnecting heterogeneous database management systems

    NASA Technical Reports Server (NTRS)

    Gligor, V. D.; Luckenbaugh, G. L.

    1984-01-01

    It is pointed out that there is still a great need for the development of improved communication between remote, heterogeneous database management systems (DBMS). Problems regarding the effective communication between distributed DBMSs are primarily related to significant differences between local data managers, local data models and representations, and local transaction managers. A system of interconnected DBMSs which exhibit such differences is called a network of distributed, heterogeneous DBMSs. In order to achieve effective interconnection of remote, heterogeneous DBMSs, the users must have uniform, integrated access to the different DBMs. The present investigation is mainly concerned with an analysis of the existing approaches to interconnecting heterogeneous DBMSs, taking into account four experimental DBMS projects.

  10. Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

    PubMed

    Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian

    2017-11-01

    The purpose of this in vitro study was to compare the precision of fit of frameworks milled from semi-sintered regular zirconia and high-translucent (HT) zirconia blanks, fabricated with two different CAD/CAM systems. Three-unit, posterior fixed dental prostheses (FDP) frameworks were fabricated for standardized dies (n = 11) with two different laboratory computer-aided design (CAD)/computer-aided manufacturing (CAM) systems (Cercon/Ceramill). The replica technique was used to evaluate the marginal and internal fit under an optical microscope. Evaluation of the data was performed according to prior studies at a level of significance of 5%. The systems showed a statistically significant influence on the internal fit of the frameworks (p ≤ 0.001) and on the marginal fit (p < 0.001). The type of material showed no influence on the marginal fit for the Cercon system (p = 0.636) and on the marginal fit (p = 0.064) and the internal fit (p = 0.316) for the Ceramill system, while regular zirconia from Cercon showed higher internal values than HT zirconia (p = 0.016). Both investigated systems showed clinically acceptable values within the limitations of this in vitro study. However, one showed less internal accuracy when regular zirconia was used.

  11. Differences between centric relation and maximum intercuspation as possible cause for development of temporomandibular disorder analyzed with T-scan III

    PubMed Central

    Lila-Krasniqi, Zana D.; Shala, Kujtim Sh.; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Dula, Linda J.; Guguvčevski, Ljuben

    2015-01-01

    Objective: To compare subjects from the group with fixed dentures, the group who present temporomandibular disorders (TMDs) and a control group considering centric relation (CR) and maximum intercuspation (MIC)/habitual occlusion (Hab. Occl.) and to analyze the related variables also compared and analyzed with electronic system T-scan III. Materials and Methods: A total of 54 subjects were divided into three groups; 17 subjects with fixed dentures, 14 with TMD and 23 controls-selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analyzed with electronic system T-scan III. Occlusal force, presented by percentage (automatically by the T-scan electronic system) was analyzed in CR and in MIC. Results: Data were presented as mean ± standard deviation and differences in P < 0.05 were considered significant. After measurements of the differences between CR and MIC in the three groups were noticed varieties but the P > 0.05 it was not significant in all three groups. Conclusion: In our study, it was concluded that there are not statistically significant differences between CR and MIC in the group of individuals without any symptom or sign of TMD although there are noticed in the group with TMD and fixed dentures disharmonic relation between the arches with overload of the occlusal force on the one side. PMID:26929698

  12. Discrimination of time-dependent inflow properties with a cooperative dynamical system.

    PubMed

    Ueno, Hiroshi; Tsuruyama, Tatsuaki; Nowakowski, Bogdan; Górecki, Jerzy; Yoshikawa, Kenichi

    2015-10-01

    Many physical, chemical, and biological systems exhibit a cooperative or sigmoidal response with respect to the input. In biochemistry, such behavior is called an allosteric effect. Here, we demonstrate that a system with such properties can be used to discriminate the amplitude or frequency of an external periodic perturbation. Numerical simulations performed for a model sigmoidal kinetics illustrate that there exists a narrow range of frequencies and amplitudes within which the system evolves toward significantly different states. Therefore, observation of system evolution should provide information about the characteristics of the perturbation. The discrimination properties for periodic perturbation are generic. They can be observed in various dynamical systems and for different types of periodic perturbation.

  13. Amniotic fluid RNA gene expression profiling provides insights into the phenotype of Turner syndrome.

    PubMed

    Massingham, Lauren J; Johnson, Kirby L; Scholl, Thomas M; Slonim, Donna K; Wick, Heather C; Bianchi, Diana W

    2014-09-01

    Turner syndrome is a sex chromosome aneuploidy with characteristic malformations. Amniotic fluid, a complex biological material, could contribute to the understanding of Turner syndrome pathogenesis. In this pilot study, global gene expression analysis of cell-free RNA in amniotic fluid supernatant was utilized to identify specific genes/organ systems that may play a role in Turner syndrome pathophysiology. Cell-free RNA from amniotic fluid of five mid-trimester Turner syndrome fetuses and five euploid female fetuses matched for gestational age was extracted, amplified, and hybridized onto Affymetrix(®) U133 Plus 2.0 arrays. Significantly differentially regulated genes were identified using paired t tests. Biological interpretation was performed using Ingenuity Pathway Analysis and BioGPS gene expression atlas. There were 470 statistically significantly differentially expressed genes identified. They were widely distributed across the genome. XIST was significantly down-regulated (p < 0.0001); SHOX was not differentially expressed. One of the most highly represented organ systems was the hematologic/immune system, distinguishing the Turner syndrome transcriptome from other aneuploidies we previously studied. Manual curation of the differentially expressed gene list identified genes of possible pathologic significance, including NFATC3, IGFBP5, and LDLR. Transcriptomic differences in the amniotic fluid of Turner syndrome fetuses are due to genome-wide dysregulation. The hematologic/immune system differences may play a role in early-onset autoimmune dysfunction. Other genes identified with possible pathologic significance are associated with cardiac and skeletal systems, which are known to be affected in females with Turner syndrome. The discovery-driven approach described here may be useful in elucidating novel mechanisms of disease in Turner syndrome.

  14. The Operating System Jungle: Finding a Common Path Keeps Getting More Difficult.

    ERIC Educational Resources Information Center

    Pournelle, Jerry

    1984-01-01

    Describes the computer field before the advent of CP/M (Control Program for Microcomputers), an operating system which facilitated compatibility between different computers. CP/M's functions and flaws and the advent of Apple DOS and UCSD Pascal, two additional widely used operating systems, and the significance of their development are also…

  15. Significance of a Recurring Function in Energy Transfer

    ERIC Educational Resources Information Center

    Mishra, Subodha

    2017-01-01

    The appearance of a unique function in the energy transfer from one system to the other in different physical situations such as electrical, mechanical, optical, and quantum mechanical processes is established in this work. Though the laws governing the energy transformation and its transfer from system to system are well known, here we notice a…

  16. Causes of mortality in laying hens in different housing systems in 2001 to 2004

    PubMed Central

    Fossum, Oddvar; Jansson, Désirée S; Etterlin, Pernille Engelsen; Vågsholm, Ivar

    2009-01-01

    Background The husbandry systems for laying hens were changed in Sweden during the years 2001 – 2004, and an increase in the number of submissions for necropsy from laying hen farms was noted. Hence, this study was initiated to compare causes of mortality in different housing systems for commercial laying hens during this change. Methods Based on results from routine necropsies of 914 laying hens performed at the National Veterinary Institute (SVA) in Uppsala, Sweden between 2001 and 2004, a retrospective study on the occurrence of diseases and cannibalism, i.e., pecking leading to mortality, in different housing systems was carried out. Using the number of disease outbreaks in caged flocks as the baseline, the expected number of flocks with a certain category of disease in the other housing systems was estimated having regard to the total number of birds in the population. Whether the actual number of flocks significantly exceeded the expected number was determined using a Poisson distribution for the variance of the baseline number, a continuity correction and the exact value for the Poisson distribution function in Excel 2000. Results Common causes of mortality in necropsied laying hens included colibacillosis, erysipelas, coccidiosis, red mite infestation, lymphoid leukosis and cannibalism. Less common diagnoses were Newcastle Disease, pasteurellosis and botulism. Considering the size of the populations in the different housing systems, a larger proportion of laying hens than expected was submitted for necropsy from litter-based systems and free range production compared to hens in cages (P < 0.001). The study showed a significantly higher occurrence of bacterial and parasitic diseases and cannibalism in laying hens kept in litter-based housing systems and free-range systems than in hens kept in cages (P < 0.001). The occurrence of viral diseases was significantly higher in indoor litter-based housing systems than in cages (P < 0.001). Conclusion The results of the present study indicated that during 2001–2004 laying hens housed in litter-based housing systems, with or without access to outdoor areas, were at higher risk of infectious diseases and cannibalistic behaviour compared to laying hens in cages. Future research should focus on finding suitable prophylactic measures, including efficient biosecurity routines, to reduce the risk of infectious diseases and cannibalism in litter-based housing systems for laying hens. PMID:19146656

  17. Overview of timing/synchronization for digital communications

    NASA Technical Reports Server (NTRS)

    Stover, H. A.

    1978-01-01

    Systems in general, and switched systems in particular, are explained. It pointed out some of the criteria that greatly influence timing/synchronization subsystem design for a military communications network but have little or no significance for civil systems. Timing techniques were evaluated in terms of fundamental features. Different combinations of these features covered most possibilities from which a synchronous timing system could be chosen.

  18. A Randomized, Investigator-Blinded Comparison of Two Topical Regimens in Fitzpatrick Skin Types III-VI With Moderate to Severe Facial Hyperpigmentation.

    PubMed

    Vanaman Wilson, Monique J; Jones, Isabela T; Bolton, Joanna; Larsen, Lisa; Wu, Douglas C; Goldman, Mitchel P

    2017-11-01

    Purpose: Though hydroquinone (HQ) remains the gold standard for treatment of hyperpigmentation, concerns about its safety have prompted the development of HQ-free topical skin lightening systems. To compare the efficacy and tolerability of a new HQ-free system and a popular HQ-based system for the improvement of facial hyperpigmentation and photoaging in darker skin types. This investigator-blinded trial randomized 30 subjects of Fitzpatrick skin types III to VI with moderate to severe hyperpigmentation to a new 7-product HQ-free system or a 7-product HQ-based system for 12 weeks. At 4, 8, and 12 week follow-up visits, a blinded investigator assessed efficacy and tolerability using standardized scales. Subjects also performed a self-assessment at each visit. Both the HQ-free and HQ-based systems produced significant improvements in Overall Hyperpigmentation that were sustained through week 12 (P=0.008, 0.0003). The HQ-based system demonstrated better improvement in overall hyperpigmentation at weeks 4, 8, 12 (P=0.01, 0.001, 0.003, respectively). Mottled Pigmentation Area Severity Index (MoPASI) scores improved with both systems (P=0.02, 0.01), with no statistically significant differences between the two treatment groups. Subject-rated hyperpigmentation was not different between groups. Subjects reported significantly more discomfort with the HQ-free system at week 8 (P=0.02); otherwise, measures of irritation were the same between groups. All irritation was described as mild to moderate. At week 12, 100% of subjects in the HQ-free group and 92.3% of subjects in the HQ-based group were satisfied with their outcome. Both a new HQ-free skincare system and a widely-available HQ-based system improved hyperpigmentation in Fitzpatrick skin types III to VI. Though the HQ-based system produced greater improvement in hyperpigmentation when compared to the HQ-free system, there was no difference in MoPASI scores between the treatment groups. Subjects were satisfied with both treatments and reported only mild to moderate irritation using either system.

    J Drugs Dermatol. 2017;16(11):1127-1132.

    .

  19. Serological Prevalence of Enteropathogenic Yersinia spp. in Pigs and Wild Boars from Different Production Systems in the Moravian Region, Czech Republic.

    PubMed

    Lorencova, Alena; Babak, Vladimir; Lamka, Jiri

    2016-05-01

    Human yersiniosis caused by pathogenic Yersinia spp. is one of the most common reported zoonoses in the European Union and pigs are considered as the major reservoir of these bacteria. Serological testing represents a suitable method to obtain information about the prevalence of enteropathogenic Yersinia spp. in food animals. The prevalence of antibodies against enteropathogenic Yersinia spp. was studied in 319 slaughtered pigs and 135 wild boars from different production systems in the Moravian region (Czech Republic) using a commercially available ELISA test (an apparent prevalence). The seroprevalence was significantly associated with the type of breeding system, with the lowest seroprevalence being observed in household-raised pigs (13/29, 44.8%). No significant difference between the prevalence of anti-Yersinia antibodies in conventional (146/180, 81.1%) and organic pigs (92/110, 83.6%) was found. Antibodies were found in 65.9% (89/135) of wild boars without a significant difference between adult (23/41, 56.1%) and young (66/94, 70.2%) animals. Seropositivity was significantly higher in domestic (251/319, 78.7% in total) compared to feral pigs. A Bayesian approach taking into account the sensitivity and specificity of the ELISA test was used to estimate the true prevalence of anti-Yersinia antibodies in pigs and wild boars. According to our results, domestic pigs and wild boars proved to be an important reservoir of enteropathogenic Yersinia in the Czech Republic. Attention should be paid to good hygienic practice during slaughtering and handling of meat to prevent meat contamination and subsequently human infection.

  20. Rangeland degradation in savannas of South Africa: spatial patterns of soil and vegetation

    NASA Astrophysics Data System (ADS)

    Sandhage-Hofmann, Alexandra; Löffler, Jörg; du Preez, Chris; Kotzé, Elmarie; Weijers, Stef; Wundram, Dirk; Zacharias, Maximilan; Amelung, Wulf

    2017-04-01

    Extensive bush encroachment by Acacia mellifera and associated woody species at semi-arid and arid sites are the most notable forms of rangeland degradation in savannas of South Africa. Concerns are growing over the threat of suppression and loss of nutritious perennial grass species. Grazing and different rangeland management systems (communal and freehold) are considered to be of major importance for degradation, but the process of encroachment is not restricted to communal land. A vegetation change is mostly accompanied by changes in soil properties, where soils in savanna systems can profit from woody species due to litter fall, root distribution, shadow and animal resting time. Savannas are very heterogeneous systems with high spatial variation of patches with wood, herbaceous species and bare ground. We hypothesized that the spatial patterns of soil properties in South Africás rangelands are controlled by present or past vegetation, modulated by the tenure systems with higher rangeland degradation in communal areas. To test this, we sampled soils at communal and commercial land in the Kuruman area of South Africa with the following design: three farms per tenure system, 6 randomly chosen plots (100x100m) per farm, and 25 soil samples (0-10 cm) per plot, each in a 5x5m sampling area. At every sampling point, information of overlying vegetation was recorded (species or bare soil, canopy size, height). For each sampling area, if present, trees/ shrubs were sampled and their ages estimated through the counting of annual growth rings. For each plot, high resolution UAV aerial photos were taken to evaluate the extent of bush encroachment. Analyses involved main physical and chemical soil parameters and isotopic analyses. The results of a rough aerial image classification (grass, woody species, bare ground) revealed significant differences between the tenure systems with higher coverage of bare ground and shrubs at communal farms, and higher grass cover at commercial farms. The tenure systems had no differences in main texture classes of the soils, but significant differences in the composition of the sand fraction, with higher levels of fine sand and lower levels of coarse sand in communal farms. The chemical soil properties showed a high variability both within and between the farms, with much higher variability within communal than commercial farms. Additionally, concentrations of nitrogen, carbon, calcium and pH were significant higher in communal farms. Isotopic analyses in soils showed significant differences for 15N with higher levels in commercial farms. Different photosynthetic pathways are responsible for differences found in 13C values, with higher levels (-16-18‰) in C4-grassland and lower values (-22-26‰) in soils under Acacia (C3). We found relationships between soil properties and species or bare ground, where differences in texture likely interact with both, vegetation cover and soil properties.

  1. Effect of Gender on the Knowledge of Medicinal Plants: Systematic Review and Meta-Analysis

    PubMed Central

    Torres-Avilez, Wendy; de Medeiros, Patrícia Muniz

    2016-01-01

    Knowledge of medicinal plants is not only one of the main components in the structure of knowledge in local medical systems but also one of the most studied resources. This study uses a systematic review and meta-analysis of a compilation of ethnobiological studies with a medicinal plant component and the variable of gender to evaluate whether there is a gender-based pattern in medicinal plant knowledge on different scales (national, continental, and global). In this study, three types of meta-analysis are conducted on different scales. We detect no significant differences on the global level; women and men have the same rich knowledge. On the national and continental levels, significant differences are observed in both directions (significant for men and for women), and a lack of significant differences in the knowledge of the genders is also observed. This finding demonstrates that there is no gender-based pattern for knowledge on different scales. PMID:27795730

  2. Natural and artificial feeding management before weaning promote different rumen microbial colonization but not differences in gene expression levels at the rumen epithelium of newborn goats

    PubMed Central

    Abecia, Leticia; Jiménez, Elisabeth; Martínez-Fernandez, Gonzalo; Martín-García, A. Ignacio; Ramos-Morales, Eva; Pinloche, Eric; Denman, Stuart E.; Newbold, C. Jamie

    2017-01-01

    The aim of this work was to evaluate the effect of feeding management during the first month of life (natural with the mother, NAT, or artificial with milk replacer, ART) on the rumen microbial colonization and the host innate immune response. Thirty pregnant goats carrying two fetuses were used. At birth one kid was taken immediately away from the doe and fed milk replacer (ART) while the other remained with the mother (NAT). Kids from groups received colostrum during first 2 days of life. Groups of four kids (from ART and NAT experimental groups) were slaughtered at 1, 3, 7, 14, 21 and 28 days of life. On the sampling day, after slaughtering, the rumen content was sampled and epithelial rumen tissue was collected. Pyrosequencing analyses of the bacterial community structure on samples collected at 3, 7, 14 and 28 days showed that both systems promoted significantly different colonization patterns (P = 0.001). Diversity indices increased with age and were higher in NAT feeding system. Lower mRNA abundance was detected in TLR2, TLR8 and TLR10 in days 3 and 5 compared to the other days (7, 14, 21 and 28). Only TLR5 showed a significantly different level of expression according to the feeding system, presenting higher mRNA abundances in ART kids. PGLYRP1 showed significantly higher abundance levels in days 3, 5 and 7, and then experienced a decline independently of the feeding system. These observations confirmed a highly diverse microbial colonisation from the first day of life in the undeveloped rumen, and show that the colonization pattern substantially differs between pre-ruminants reared under natural or artificial milk feeding systems. However, the rumen epithelial immune development does not differentially respond to distinct microbial colonization patterns. PMID:28813529

  3. Natural and artificial feeding management before weaning promote different rumen microbial colonization but not differences in gene expression levels at the rumen epithelium of newborn goats.

    PubMed

    Abecia, Leticia; Jiménez, Elisabeth; Martínez-Fernandez, Gonzalo; Martín-García, A Ignacio; Ramos-Morales, Eva; Pinloche, Eric; Denman, Stuart E; Newbold, C Jamie; Yáñez-Ruiz, David R

    2017-01-01

    The aim of this work was to evaluate the effect of feeding management during the first month of life (natural with the mother, NAT, or artificial with milk replacer, ART) on the rumen microbial colonization and the host innate immune response. Thirty pregnant goats carrying two fetuses were used. At birth one kid was taken immediately away from the doe and fed milk replacer (ART) while the other remained with the mother (NAT). Kids from groups received colostrum during first 2 days of life. Groups of four kids (from ART and NAT experimental groups) were slaughtered at 1, 3, 7, 14, 21 and 28 days of life. On the sampling day, after slaughtering, the rumen content was sampled and epithelial rumen tissue was collected. Pyrosequencing analyses of the bacterial community structure on samples collected at 3, 7, 14 and 28 days showed that both systems promoted significantly different colonization patterns (P = 0.001). Diversity indices increased with age and were higher in NAT feeding system. Lower mRNA abundance was detected in TLR2, TLR8 and TLR10 in days 3 and 5 compared to the other days (7, 14, 21 and 28). Only TLR5 showed a significantly different level of expression according to the feeding system, presenting higher mRNA abundances in ART kids. PGLYRP1 showed significantly higher abundance levels in days 3, 5 and 7, and then experienced a decline independently of the feeding system. These observations confirmed a highly diverse microbial colonisation from the first day of life in the undeveloped rumen, and show that the colonization pattern substantially differs between pre-ruminants reared under natural or artificial milk feeding systems. However, the rumen epithelial immune development does not differentially respond to distinct microbial colonization patterns.

  4. From Smart Metering to Smart Grid

    NASA Astrophysics Data System (ADS)

    Kukuča, Peter; Chrapčiak, Igor

    2016-06-01

    The paper deals with evaluation of measurements in electrical distribution systems aimed at better use of data provided by Smart Metering systems. The influence of individual components of apparent power on the power loss is calculated and results of measurements under real conditions are presented. The significance of difference between the traditional and the complex evaluation of the electricity consumption efficiency by means of different definitions of the power factor is illustrated.

  5. [Distribution of sediment iron of the ditch system in Sanjiang Plain, northeast China].

    PubMed

    Zou, Yuan-Chun; Lü, Xian-Guo; Jiang, Ming; Xi, Min

    2009-03-15

    The iron distribution of the multi-level ditch system (hair canal-field canal-lateral canal-branch canal-main canal) was studied through total iron determination of the sediments (0-60 cm). The results showed that the mean concentration was (3.02 +/- 0.10) x 10(4) mg x kg(-1). Extremely significant difference was obseved between different ditch level (F = 6.261, p < 0.001), and the highest and the lowest concentration were present in the farmland lateral canal (3.71 x 10(4) mg x kg(-1)) and wetland canal (2.43 x 10(4) mg x kg(-1)), respectively. The difference of different sediment layers was not significant (F = 0.093, p = 0.693), while the iron concentrations of 0-10 cm and 10-20 cm sediments were 51.96% and 62.22% higher than that of the natural wetland soil nearby, respectively. Iron can transfer with the runoff in a certain extent, but it was not cumulated along the ditch system with the largest cumulation location at the third level. The runoff containing iron decreased gradully because of the wetland protection and climate change nowadays. The horizontal transfer of iron along the ditch system indicated the timing and intensity of iron loss in the past since the canals were dredged.

  6. Designing and Constructing an Optical Monitoring System of Blood Supply to Tissues under Pressure.

    PubMed

    Hadi, Akbari; Amin, Younessi Heravi Mohammad

    2012-04-01

    Reduced blood flow due to obstruction is in most cases a primary factor in pressure ulcer formation and creation of bedsores. The aim of this study is to design and manufacture a care system for tissue under pressure, based on variations in blood flow at different depths of tissue. In the manufacture of the system two infrared light transmitters and receivers were located between 5 and 10 mm depth to measure the flow of blood at different in the under- pressure heel tissue. In addition, blood flow was evaluated in an unloaded and loaded condition, with 30 mmHg and 60.0 mmHg. A total of 15 people participated with a mean age of 50. Of these 15; 9 (60%) were men and 6 (40%) were women. Primary measurement results showed different individual differences in variation of blood flow in the tissue. To study signal amplitude changes significantly influenced by external pressure the PPG, P-value was measured. It was noted that there were significant changes in PPG signal amplitude during loading both pressures of 30 and 60 mmHg. Further development of this system would be possible with the use of a more flexible probe and by using a stronger optical receiver and transmitter to access more depth.

  7. Impact of audio narrated animation on students' understanding and learning environment based on gender

    NASA Astrophysics Data System (ADS)

    Nasrudin, Ajeng Ratih; Setiawan, Wawan; Sanjaya, Yayan

    2017-05-01

    This study is titled the impact of audio narrated animation on students' understanding in learning humanrespiratory system based on gender. This study was conducted in eight grade of junior high school. This study aims to investigate the difference of students' understanding and learning environment at boys and girls classes in learning human respiratory system using audio narrated animation. Research method that is used is quasy experiment with matching pre-test post-test comparison group design. The procedures of study are: (1) preliminary study and learning habituation using audio narrated animation; (2) implementation of learning using audio narrated animation and taking data; (3) analysis and discussion. The result of analysis shows that there is significant difference on students' understanding and learning environment at boys and girls classes in learning human respiratory system using audio narrated animation, both in general and specifically in achieving learning indicators. The discussion related to the impact of audio narrated animation, gender characteristics, and constructivist learning environment. It can be concluded that there is significant difference of students' understanding at boys and girls classes in learning human respiratory system using audio narrated animation. Additionally, based on interpretation of students' respond, there is the difference increment of agreement level in learning environment.

  8. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

    PubMed Central

    Geerts, Sabine; Bolette, Amandine; Seidel, Laurence; Guéders, Audrey

    2012-01-01

    Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Multipurpose (SBMP), a 3-step Etch and Rinse adhesive, Adper Scotchbond 1 XT (SB1), a 2-step Etch and Rinse adhesive, AdheSE One (ADSE-1), a 1-step Self-Etch adhesive, and AdheSE (ADSE), a 2-step Self-Etch adhesive. Teeth were thermocycled and immersed in 50% silver nitrate solution. When both interfaces were considered, SBMP has exhibited significantly less microleakage than other adhesive systems (resp., for SB1, ADSE-1 and ADSE, P = 0.0007, P < 0.0001 and P < 0.0001). When enamel and dentin interfaces were evaluated separately, (1) for the Self-Etch adhesives, microleakage was found greater at enamel than at dentin interfaces (for ADSE, P = 0.024 and for ADSE-1, P < 0.0001); (2) for the Etch and Rinse adhesive systems, there was no significant difference between enamel and dentin interfaces; (3) SBMP was found significantly better than other adhesives both at enamel and dentin interfaces. In our experiment Etch and Rinse adhesives remain better than Self-Etch adhesives at enamel interface. In addition, there was no statistical difference between 1-step (ADSE-1) and 2-step (ADSE) Self-Etch adhesives. PMID:22675358

  9. Comparison of lancing devices for self-monitoring of blood glucose regarding lancing pain.

    PubMed

    Kocher, Serge; Tshiananga, J K Tshiang; Koubek, Richard

    2009-09-01

    Self-monitoring of blood glucose empowers diabetes patients to effectively control their blood glucose (BG) levels. A potential barrier to frequent BG controls is lancing pain, intrinsically linked to pricking the finger several times a day. In this study, we compared different state-of-the-art lancing devices from leading manufacturers regarding lancing pain, and we intended to identify lancing devices that are less painful. First, 165 subjects compared 6 different BG monitoring systems-consisting of a lancing device and a BG meter-at home for 36 days and at least 3 BG tests per day. Second, the subjects directly compared 6 different lancing devices-independent from a BG meter-in a laboratory setting. The test results were collected in questionnaires, and lancing pain was rated on a numerical rating scale. One hundred fifty-seven subjects were included in the analysis. Accu-Chek BG monitoring systems were significantly (p < or = .006) preferred to competitor BG monitoring systems and were rated by >50% of the subjects as "less painful" than competitor BG monitoring systems. Accu-Chek lancing devices were significantly (p < .001) preferred to competitor lancing devices and were rated by >60% of the subjects as "less painful" than competitor lancing devices. We found significant differences in lancing pain between lancing devices. Diabetes patients clearly preferred lancing devices that cause less lancing pain. In order to improve patient compliance with respect to an adequate glycemic control, the medical staff should preferentially prescribe lancing devices that cause less lancing pain. 2009 Diabetes Technology Society.

  10. A comparison of artificial turf.

    PubMed

    Naunheim, Rosanne; Parrott, Heather; Standeven, John

    2004-12-01

    In an attempt to decrease injuries, newer forms of artificial turf have been marketed. The purpose of this study was to determine whether a new shredded rubber-based turf improves impact attenuation. An instrumented computerized impact recording device (IRD, Techmark, Lansing, MI) was dropped 20 times from a height of 48 inches onto five types of turf used by a professional football team. Duncan's multiple range test shows that the new rubber-based field and the older foam field are not significantly different. There were significant differences, however, between sites on the shredded rubber-based field. The change from a foam-based system to a shredded rubber-based system had no effect on impact attenuation overall. However, areas in the shredded rubber-based field were significantly compacted, causing some sites to be much harder than the foam-based surface it replaced.

  11. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    PubMed

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  12. Evaluation of the effect scan pattern has on the trueness and precision of six intraoral digital impression systems.

    PubMed

    Mennito, Anthony S; Evans, Zachary P; Lauer, Abigail W; Patel, Ravi B; Ludlow, Mark E; Renne, Walter G

    2018-03-01

    Clinicians have been slow to adopt digital impression technologies due possibly to perceived technique sensitivities involved in data acquisition. This research has two aims: determine whether scan pattern and sequence affects the accuracy of the three-dimensional (3D) model created from this digital impression and to compare the 5 imaging systems with regards to their scanning accuracy for sextant impressions. Six digital intraoral impression systems were used to scan a typodont sextant with optical properties similar to natural teeth. The impressions were taken using five different scan patterns and the resulting digital models were overlayed on a master digital model to determine the accuracy of each scanner performing each scan pattern. Furthermore, regardless of scan pattern, each digital impression system was evaluated for accuracy to the other systems in this same manner. No differences of significance were noted in the accuracy of 3D models created using six distinct scan patterns with one exception involving the CEREC Omnicam. Planmeca Planscan was determined to be the truest scanner while 3Shape Trios was determined to be the most precise for sextant impression making. Scan pattern does not significantly affect the accuracy of the resulting digital model for sextant scanning. Companies who make digital impression systems often recommend a scan pattern specific for their system. However, every clinical scanning scenario is different and may require a different approach. Knowing how important scan pattern is with regards to accuracy would be helpful for guiding a growing number of practitioners who are utilizing this technology. © 2018 Wiley Periodicals, Inc.

  13. Entomofauna Associated with Agroforestry Systems of Timber Species and Cacao in the Southern Region of the Maracaibo Lake Basin (Mérida, Venezuela).

    PubMed

    Mazón, Marina; Sánchez-Angarita, Daniel; Díaz, Francisco A; Gutiérrez, Néstor; Jaimez, Ramón

    2018-04-20

    Agroforestry systems are environment-friendly production systems which help to preserve biodiversity while providing people with a way of earning a living. Cacao is a historically important crop in Venezuela that traditionally has been produced in agroforestry systems. However, few studies have evaluated how different trees used in those systems affect the dynamics and abundance of insects. The present study evaluated the entomofauna assemblages associated with different combinations of four timber-yielding trees and four Criollo cacao cultivars established in a lowland tropical ecosystem in Venezuela. A randomized block design with two replicates was used, each block having 16 plots which included all 16 possible combinations of four native timber trees ( Cordia thaisiana , Cedrela odorata , Swietenia macrophylla , and Tabebuia rosea ) and four Criollo cacao cultivars (Porcelana, Guasare, Lobatera and Criollo Merideño). Insects were collected with yellow pan traps and sorted to order. Coleoptera and parasitoid Hymenoptera were determined to the family level. In total, 49,538 individuals of seven orders were collected, with Hymenoptera, Diptera, and Hemiptera being the most abundant, although only Lepidoptera and Coleoptera abundances were significantly influenced by the timber tree species. Twenty-three families of parasitoid Hymenoptera and 26 of Coleoptera were found. Significant differences in insects’ assemblages were found both in parasitoid Hymenoptera and Coleoptera families associated to every shade tree, with the families Eulophidae and Lycidae being indicators for Cordia , and Chalcididae for Swietenia . The entomofauna relationship with the cacao cultivar was barely significant, although Scydmaenidae and Scarabaeidae were indicators for Lobatera and Merideño, respectively. No significant effects were found for interaction with cacao cultivars and native trees. We concluded that the particular insect assemblages found in Cedrela odorata and Cordia thaisiana , together with their high growing rates, make these two species an optimal choice for cacao agroforestry systems.

  14. Significance of Age in Japanese Patients Receiving Sunitinib as First-line Systemic Therapy for Metastatic Renal Cell Carcinoma: Comparative Assessment of Efficacy and Safety between Patients Aged <75 and ≥75 Years.

    PubMed

    Miyake, Hideaki; Aki, Ryota; Matsushita, Yuto; Tamura, Keita; Motoyama, Daisuke; Ito, Toshiki; Sugiyama, Takayuki; Otsuka, Atsushi

    2018-06-01

    To date, it has not been well characterized whether sunitinib is effective in elderly patients with metastatic renal cell carcinoma (mRCC). The objective of this study was to investigate the impact of age on clinical outcomes of mRCC patients receiving sunitinib. The efficacy and safety of first-line sunitinib in 154 consecutive mRCC patients were retrospectively compared between patients aged <75 (n=125) and ≥75 (n=29) years. There were no significant differences in the major clinicopathological characteristics between younger and older patients; however, the reduction of the initial dose of sunitinib was significantly more frequent in older than younger patients. No significant difference in response rate, clinical benefit rate or proportion of patients going on to receive second-line therapy was noted between these two groups. Furthermore, there was no significant difference in progression-free survival (PFS) or overall survival (OS) between the two groups, and no significant impact of age on PFS or OS was documented by the Cox proportional hazards regression analyses. Of several adverse events, only anemia and fatigue were significantly more frequently observed in older than younger patients. Although there was no significant difference in the incidence of dose reduction or discontinuation of sunitinib between the two groups, the interruption of sunitinib was more frequently required in older than younger patients. These findings suggest that advanced age alone should not be regarded as a contraindication to the introduction of sunitinib as first-line systemic therapy for mRCC patients. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  15. Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems.

    PubMed

    Wirtzfeld, Lauren A; Ghoshal, Goutam; Rosado-Mendez, Ivan M; Nam, Kibo; Park, Yeonjoo; Pawlicki, Alexander D; Miller, Rita J; Simpson, Douglas G; Zagzebski, James A; Oelze, Michael L; Hall, Timothy J; O'Brien, William D

    2015-08-01

    Quantitative ultrasound estimates such as the frequency-dependent backscatter coefficient (BSC) have the potential to enhance noninvasive tissue characterization and to identify tumors better than traditional B-mode imaging. Thus, investigating system independence of BSC estimates from multiple imaging platforms is important for assessing their capabilities to detect tissue differences. Mouse and rat mammary tumor models, 4T1 and MAT, respectively, were used in a comparative experiment using 3 imaging systems (Siemens, Ultrasonix, and VisualSonics) with 5 different transducers covering a range of ultrasonic frequencies. Functional analysis of variance of the MAT and 4T1 BSC-versus-frequency curves revealed statistically significant differences between the two tumor types. Variations also were found among results from different transducers, attributable to frequency range effects. At 3 to 8 MHz, tumor BSC functions using different systems showed no differences between tumor type, but at 10 to 20 MHz, there were differences between 4T1 and MAT tumors. Fitting an average spline model to the combined BSC estimates (3-22 MHz) demonstrated that the BSC differences between tumors increased with increasing frequency, with the greatest separation above 15 MHz. Confining the analysis to larger tumors resulted in better discrimination over a wider bandwidth. Confining the comparison to higher ultrasonic frequencies or larger tumor sizes allowed for separation of BSC-versus-frequency curves from 4T1 and MAT tumors. These constraints ensure that a greater fraction of the backscattered signals originated from within the tumor, thus demonstrating that statistically significant tumor differences were detected. © 2015 by the American Institute of Ultrasound in Medicine.

  16. Heat exchangers for cardioplegia systems: in vitro study of four different concepts.

    PubMed

    Drummond, Mário; Novello, Waldyr Parorali; de Arruda, Antonio Celso Fonseca; Braile, Domingo Marcolino

    2003-05-01

    The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber, and bellows type. The evaluation was performed by in vitro tests of parameters such as heat transfer, pressure drop, and hemolysis tendency. The result has shown that all four systems tested were able to achieve the heat performance, and to offer low resistance to flow, and safety, as well as have low tendency to hemolysis. However, we can emphasize that the bellows type heat exchanger has a significant difference with regard to the other three types.

  17. Inhibition of demineralization around the enamel-dentin/restoration interface after dentin pretreatment with TiF4 and self-etching adhesive systems.

    PubMed

    Bridi, Enrico Coser; do Amaral, Flávia Lucisano Botelho; França, Fabiana Mantovani Gomes; Turssi, Cecilia Pedroso; Basting, Roberta Tarkany

    2016-05-01

    The objective of this study was to evaluate the inhibition of demineralization around enamel-dentin/restoration interface after dentin pretreatment with 2.5% titanium tetrafluoride (TiF4). Forty dental class V cavities at the cementoenamel junction were distributed into four groups (n = 10), according to the presence or absence of TiF4 and to the adhesive system (Clearfil SE Bond/CL and Adper EasyOne/AD), and restored with a resin composite. A dynamic pH cycling model was used to induce the development of artificial caries lesions. After sectioning the dental blocks, Knoop microhardness tests were performed at different depths (20, 40, and 60 μm from the occlusal margin of the restoration) and at different distances (100, 200, and 300 μm from the adhesive interface). Repeated measures three-way analysis of variance (ANOVA) and Tukey's test were used (α = 0.05). For enamel, there were no differences in the microhardness values for CL, AD, and TiF4-AD at depths, regardless of the distances. Considering each depth, there were no significant differences among treatments. For dentin, ANOVA showed no significant interaction among the independent variables treatment*distance*depth (p = 0.994), no significant interaction between treatment*depth (p = 0.722), no significant interaction between treatment*distance (p = 0.265), no significant interaction between depth*distance (p = 0.365), and no significant effect on treatment (p = 0.151), depth (p = 0.067), or distance (p = 0.251). Dentin pretreatment of the cavity walls with TiF4 before self-etching adhesive systems was not effective in inhibiting demineralization around the enamel-dentin/restoration interfaces. The mechanism of incorporating fluoride in enamel and dentin of the cavity walls to inhibit demineralization around restorations seems ineffective when using TiF4 as a dentin pretreatment.

  18. Release of nitrogen compounds to the extracellular medium by three strains of Saccharomyces cerevisiae during induced autolysis in a model wine system.

    PubMed

    Martínez-Rodriguez, A J; Carrascosa, A V; Polo, M C

    2001-08-15

    To detect differences among three strains of Saccharomyces cerevisiae used in the manufacture of sparkling wines and to study the changes in nitrogen compounds during autolysis, a model wine system was used. Significant differences were observed between the mean values of the autolytic capacity of the three strains. The amount of nitrogen (total, protein, peptide and amino) present in the autolysates and the concentration of most free amino acids was significantly affected by the strain. These findings suggest that the strain of yeast used in the manufacture of sparkling wines can play an important role in the aging process and can affect final composition.

  19. Evaluation of the Efficacy and Color Stability of Two Different At-Home Bleaching Systems on Teeth of Different Shades: A Randomized Controlled Clinical Trial.

    PubMed

    Aka, Betül; Celik, Esra Uzer

    2017-09-01

    This randomized controlled clinical trial compared the bleaching efficacy of two different at-home bleaching systems on teeth of different shades and their color stability after a 6-month follow-up. Ninety-two patients (777 teeth) were randomly divided into three groups: (a) negative control, (b) patients treated with a custom-made tray containing 10% carbamide peroxide (10% CP/PF) (Opalescence PF), and (c) patients treated with a pre-loaded tray containing 6% hydrogen peroxide (6% HP/Go) (Opalescence Go). Teeth in all groups were divided into three sub-groups according to the VITA Classic Shade Guide: light (A1-C1), medium dark (C2-B3), and dark (A3.5-C4). Bleaching systems were performed in accordance with manufacturers' instructions for 14 days. The color values were measured at the baseline, 10 days and 14 days of bleaching, 2 weeks, and 6 months after bleaching. Three-way ANOVA and Mann-Whitney U tests were used for statistical analysis (α = 0.05). Irrespective of original shade, both bleaching groups showed significantly higher ΔE* values than the control groups, and the ΔE* values were significantly higher in the 10% CP/PF groups than those in the 6% HP/Go groups (p < 0.05). In both bleaching systems, the dark teeth showed higher ΔE* values than the light teeth (p < 0.05). The ΔE* values decreased significantly only in the 10% CP/PF groups after 6 months (p < 0.05). Both bleaching agents produced a bleaching effect, but 10% CP/PF was more effective. A pre-loaded tray system may be used for dental bleaching, but it is still less effective than conventional a 10% carbamide peroxide system, irrespective of the initial shade. (J Esthet Restor Dent 29:325-338, 2017). © 2017 Wiley Periodicals, Inc.

  20. Juvenile hormone-dopamine systems for the promotion of flight activity in males of the large carpenter bee Xylocopa appendiculata.

    PubMed

    Sasaki, Ken; Nagao, Takashi

    2013-12-01

    The reproductive roles of dopamine and dopamine regulation systems are known in social hymenopterans, but the knowledge on the regulation systems in solitary species is still needed. To test the possibility that juvenile hormone (JH) and brain dopamine interact to trigger territorial flight behavior in males of a solitary bee species, the effects on biogenic amines of JH analog treatments and behavioral assays with dopamine injections in males of the large carpenter bee Xylocopa appendiculata were quantified. Brain dopamine levels were significantly higher in methoprene-treated males than in control males 4 days after treatment, but were not significantly different after 7 days. Brain octopamine and serotonin levels did not differ between methoprene-treated and control males at 4 and 7 days after treatment. Injection of dopamine caused significantly higher locomotor activities and a shorter duration for flight initiation in experimental versus control males. These results suggest that brain dopamine can be regulated by JH and enhances flight activities in males. The JH-dopamine system in males of this solitary bee species is similar to that of males of the highly eusocial honeybee Apis mellifera.

  1. Juvenile hormone-dopamine systems for the promotion of flight activity in males of the large carpenter bee Xylocopa appendiculata

    NASA Astrophysics Data System (ADS)

    Sasaki, Ken; Nagao, Takashi

    2013-12-01

    The reproductive roles of dopamine and dopamine regulation systems are known in social hymenopterans, but the knowledge on the regulation systems in solitary species is still needed. To test the possibility that juvenile hormone (JH) and brain dopamine interact to trigger territorial flight behavior in males of a solitary bee species, the effects on biogenic amines of JH analog treatments and behavioral assays with dopamine injections in males of the large carpenter bee Xylocopa appendiculata were quantified. Brain dopamine levels were significantly higher in methoprene-treated males than in control males 4 days after treatment, but were not significantly different after 7 days. Brain octopamine and serotonin levels did not differ between methoprene-treated and control males at 4 and 7 days after treatment. Injection of dopamine caused significantly higher locomotor activities and a shorter duration for flight initiation in experimental versus control males. These results suggest that brain dopamine can be regulated by JH and enhances flight activities in males. The JH-dopamine system in males of this solitary bee species is similar to that of males of the highly eusocial honeybee Apis mellifera.

  2. Platelet collection efficiencies of three different platelet-rich plasma preparation systems.

    PubMed

    Aydin, Fatma; Pancar Yuksel, Esra; Albayrak, Davut

    2015-06-01

    Different systems have been used for the preparation of platelet-rich plasma (PRP), but platelet collection efficiencies of these systems are not clear. To evaluate the platelet collection efficiencies of three different PRP preparation systems. Blood samples were obtained from the same 16 volunteers for each system. The samples were centrifuged and PRP was prepared by three systems. The ratio of the total number of platelets in PRP to the total number of platelets of the venous blood sample of the patient expressed in percentage was named as platelet collection efficiency and calculated for each system. Mean platelet collection efficiencies were 66.6 (min: 56.9, max: 76.9), 58.3 (min: 27.3, max: 102.8), 50.8 (min: 27.2, max: 73) for top and bottom bag system, system using citrated tube, and the system using tube with Ficoll and cell extraction kit, respectively. Statistically significant difference was found only between the platelet collection efficiencies of systems using the tube with ficoll and cell extraction kit and the top and bottom bag system (p = 0.002). All three systems could be used for PRP preparation, but top and bottom bag system offers a slight advantage over the system using Ficoll and cell extraction kit regarding the platelet collection efficiency.

  3. Does the usage of digital chest drainage systems reduce pleural inflammation and volume of pleural effusion following oncologic pulmonary resection?-A prospective randomized trial.

    PubMed

    De Waele, Michèle; Agzarian, John; Hanna, Waël C; Schieman, Colin; Finley, Christian J; Macri, Joseph; Schneider, Laura; Schnurr, Terri; Farrokhyar, Forough; Radford, Katherine; Nair, Parameswaran; Shargall, Yaron

    2017-06-01

    Prolonged air leak and high-volume pleural drainage are the most common causes for delays in chest tube removal following lung resection. While digital pleural drainage systems have been successfully used in the management of post-operative air leak, their effect on pleural drainage and inflammation has not been studied before. We hypothesized that digital drainage systems (as compared to traditional analog continuous suction), using intermittent balanced suction, are associated with decreased pleural inflammation and postoperative drainage volumes, thus leading to earlier chest tube removal. One hundred and three [103] patients were enrolled and randomized to either analog (n=50) or digital (n=53) drainage systems following oncologic lung resection. Chest tubes were removed according to standardized, pre-defined protocol. Inflammatory mediators [interleukin-1B (IL-1B), 6, 8, tumour necrosis factor-alpha (TNF-α)] in pleural fluid and serum were measured and analysed. The primary outcome of interest was the difference in total volume of postoperative fluid drainage. Secondary outcome measures included duration of chest tube in-situ, prolonged air-leak incidence, length of hospital stay and the correlation between pleural effusion formation, degree of inflammation and type of drainage system used. There was no significant difference in total amount of fluid drained or length of hospital stay between the two groups. A trend for shorter chest tube duration was found with the digital system when compared to the analog (P=0.055). Comparison of inflammatory mediator levels revealed no significant differences between digital and analog drainage systems. The incidence of prolonged post-operative air leak was significantly higher when using the analog system (9 versus 2 patients; P=0.025). Lobectomy was associated with longer chest tube duration (P=0.001) and increased fluid drainage when compared to sub-lobar resection (P<0.001), regardless of drainage system. Use of post-lung resection digital drainage does not appear to decrease pleural fluid formation, but is associated with decreased prolonged air leaks. Total pleural effusion volumes did not differ with the type of drainage system used. These findings support previously established benefits of the digital system in decreasing prolonged air leaks, but the advantages do not appear to extend to decreased pleural fluid formation.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanquist, Thomas F.; Mahy, Heidi A.; Morris, Fred A.

    Understanding the issues surrounding public acceptance of homeland security systems is important for balancing security needs and potential civil liberties infringements. A psychometric survey was used to measure attitudes regarding homeland security systems. Psychometric rating data were obtained from 182 respondents on psychological attributes associated with 12 distinct types of homeland security systems. An inverse relationship was observed for the overall rating attributes of acceptability and risk of civil liberties infringement. Principal components analysis yielded a two factor solution, with the rating scale loading pattern suggesting factors of Perceived Effectiveness and Perceived Intrusiveness. These factors also showed an inverse relationship.more » The 12 different homeland security systems showed significantly different scores on the rating scales and PCA factors, which were used to rank the systems in terms of overall acceptability. Difference scores for the rating scales and PCA factors were used to compute a single acceptability value reflecting the relative weight of risks and benefits. Of the 12 systems studied, airport screening, canine detectors and radiation monitoring at borders were found to be relatively acceptable, i.e., the perceived benefits for homeland security outweighed the perceived risks to civil liberties. Students rated several systems as more effective than professionals, but the overall pattern of results for both types of subjects was similar. The data suggest that risk perception research and the psychometric paradigm are useful approaches for quantifying attitudes regarding homeland security systems and policies, and can be used to anticipate potentially significant public acceptance issues.« less

  5. A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems.

    PubMed

    Shepherd, John A; Fan, Bo; Lu, Ying; Wu, Xiao P; Wacker, Wynn K; Ergun, David L; Levine, Michael A

    2012-10-01

    Dual-energy x-ray absorptiometry (DXA) is used to assess bone mineral density (BMD) and body composition, but measurements vary among instruments from different manufacturers. We sought to develop cross-calibration equations for whole-body bone density and composition derived using GE Healthcare Lunar and Hologic DXA systems. This multinational study recruited 199 adult and pediatric participants from a site in the US (n = 40, ages 6 through 16 years) and one in China (n = 159, ages 5 through 81 years). The mean age of the participants was 44.2 years. Each participant was scanned on both GE Healthcare Lunar and Hologic Discovery or Delphi DXA systems on the same day (US) or within 1 week (China) and all scans were centrally analyzed by a single technologist using GE Healthcare Lunar Encore version 14.0 and Hologic Apex version 3.0. Paired t-tests were used to test the results differences between the systems. Multiple regression and Deming regressions were used to derive the cross-conversion equations between the GE Healthcare Lunar and Hologic whole-body scans. Bone and soft tissue measures were highly correlated between the GE Healthcare Lunar and Hologic and systems, with r ranging from 0.96 percent fat [PFAT] to 0.98 (BMC). Significant differences were found between the two systems, with average absolute differences for PFAT, BMC, and BMD of 1.4%, 176.8 g and 0.013 g/cm(2) , respectively. After cross-calibration, no significant differences remained between GE Healthcare Lunar measured results and the results converted from Hologic. The equations we derived reduce differences between BMD and body composition as determined by GE Healthcare Lunar and Hologic systems and will facilitate combining study results in clinical or epidemiological studies. Copyright © 2012 American Society for Bone and Mineral Research.

  6. Enabling the Discovery of Recurring Anomalies in Aerospace System Problem Reports using High-Dimensional Clustering Techniques

    NASA Technical Reports Server (NTRS)

    Srivastava, Ashok, N.; Akella, Ram; Diev, Vesselin; Kumaresan, Sakthi Preethi; McIntosh, Dawn M.; Pontikakis, Emmanuel D.; Xu, Zuobing; Zhang, Yi

    2006-01-01

    This paper describes the results of a significant research and development effort conducted at NASA Ames Research Center to develop new text mining techniques to discover anomalies in free-text reports regarding system health and safety of two aerospace systems. We discuss two problems of significant importance in the aviation industry. The first problem is that of automatic anomaly discovery about an aerospace system through the analysis of tens of thousands of free-text problem reports that are written about the system. The second problem that we address is that of automatic discovery of recurring anomalies, i.e., anomalies that may be described m different ways by different authors, at varying times and under varying conditions, but that are truly about the same part of the system. The intent of recurring anomaly identification is to determine project or system weakness or high-risk issues. The discovery of recurring anomalies is a key goal in building safe, reliable, and cost-effective aerospace systems. We address the anomaly discovery problem on thousands of free-text reports using two strategies: (1) as an unsupervised learning problem where an algorithm takes free-text reports as input and automatically groups them into different bins, where each bin corresponds to a different unknown anomaly category; and (2) as a supervised learning problem where the algorithm classifies the free-text reports into one of a number of known anomaly categories. We then discuss the application of these methods to the problem of discovering recurring anomalies. In fact the special nature of recurring anomalies (very small cluster sizes) requires incorporating new methods and measures to enhance the original approach for anomaly detection. ?& pant 0-

  7. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography -An In Vitro Study.

    PubMed

    Dhingra, Annil; Ruhal, Nidhi; Miglani, Anjali

    2015-04-01

    Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (p<0.001, p =0.006, 0.004 & <0.001 respectively). There was significant difference between wave one and oneshape; oneshape and reciproc at 0mm, 1mm, 2mm & 7mm (p-values for waveone and Oneshape <0.001, 0.022, 0.011 & <0.001 resp. and for oneshape and reciproc < 0.001, p= 0.011, p=0.008 & <0.001). On assessing the transportation of the three file system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness.

  8. The online outpatient booking system 'Choose and Book' improves attendance rates at an audiology clinic: a comparative audit.

    PubMed

    Parmar, Vijal; Large, Ann; Madden, Colm; Das, Vijay

    2009-01-01

    The 'Choose and Book' system provides an online booking service which primary care professionals can book in real time or soon after a patient's consultation. It aims to offer patients choice and improve outpatient clinic attendance rates. An audit comparing attendance rates of new patients booked into the Audiological Medicine Clinic using the 'Choose and Book' system with that of those whose bookings were made through the traditional booking system. Data accrued between 1 April 2008 and 31 October 2008 were retrospectively analysed for new patient attendance at the department, and the age and sex of the patients, method of appointment booking used and attendance record were collected. Patients were grouped according to booking system used - 'Choose and Book' or the traditional system. The mean ages of the groups were compared by a t test. The standard error of the difference between proportions was used to compare the data from the two groups. A P value of < or = 0.05 was considered to be significant. 'Choose and Book' patients had a significantly better rate of attendance than traditional appointment patients, P < 0.01 (95% CI 4.3, 20.5%). There was no significant difference between the two groups in terms of sex, P > 0.1 (95% CI-3.0, 16.2%). The 'Choose and Book' patients, however, were significantly older than the traditional appointment patients, P < 0.001 (95% CI 4.35, 12.95%). This audit suggests that when primary care agents book outpatient clinic appointments online it improves outpatient attendance.

  9. An evaluation of the real-world safety effect of a lane change driver support system and characteristics of lane change crashes based on insurance claims data.

    PubMed

    Isaksson-Hellman, Irene; Lindman, Magdalena

    2018-02-28

    Lane changes, which frequently occur when vehicles travel on major roads, may contribute to critical situations that significantly affect the traffic flow and traffic safety. Thus, knowledge of lane change situations is important for infrastructure improvements as well as for driver support systems and automated driving development projects. The objectives of this study were to evaluate the crash avoidance performance of a lane change driver support system, the Blind Spot Information System (BLIS) in Volvo car models, and to describe the characteristics of lane change crashes by analyzing detailed information from insurance claim reports. An overall evaluation of the safety effect of BLIS was performed by analyzing crash rate differences in lane change situations for cars with and without the optionally mounted BLIS system based on a population of 380,000 insured vehicle years. Further, crashes in which the repair cost of the host vehicle exceeded approximately US$1,250 were selected and compared. Finally, the study examined different precrash factors and crash configurations, using in-depth insurance claims data from representative lane change crash cases including all severity levels in a population of more than 200,000 insured vehicle years. The technology did not significantly reduce the overall number of crashes when all types of lane change crashes and severity levels were considered, though a significant crash-reducing effect of 31% for BLIS cars was found when more severe crashes with a repair cost exceeding US$1,250 were analysed. Cars with the BLIS technology also have a 30% lower claim cost on average for reported lane change crashes, indicating reduced crash severity. When stratifying the data into specific situations, by collecting precrash information in a case-by-case study, the influence of BLIS was indicated to differ for the evaluated situations, although no significant results were found. For example, during general lane change maneuvers (i.e., not while exiting or entering highways or during weaving/merging situations) the crash rate was reduced by 14%, whereas in weaving/merging situations the crash rate increased. The insurance data analyzed provided useful information about real-world lane change crash characteristics by covering collisions in all crash severities and thus revealed information beyond what is available in, for example, data sets of police-reported crashes. This will guide further development of driver support systems. For crashes with repair cost exceeding US$1,250, a significant crash reduction was found, although the technology did not significantly reduce the total number of lane change crashes. An average lower insurance claim cost for cars equipped with the BLIS technology also indicated that the technology contributes to reduced crash severity even if crashes were not totally avoided. Stratifying the data into different lane change crash situations gave indications of the condition-specific performance of the system, even if the results were not statistically significant at the 95% level.

  10. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study

    PubMed Central

    Agarwal, Jatin; Jain, Pradeep; Chandra, Anil

    2015-01-01

    Background The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. Aim The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Materials and Methods Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20o to 35o were divided into three groups of 20 samples each: ProTaper PT (group I) – full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO – single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey’s honestly significant difference test. Results It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant Conclusion It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals. PMID:26155551

  11. STARS: The Space Transportation Architecture Risk System

    NASA Technical Reports Server (NTRS)

    Greenberg, Joel S.

    1997-01-01

    Because of the need to perform comparisons between transportation systems that are likely to have significantly different levels of risk, both because of differing degrees of freedom in achieving desired performance levels and their different states of development and utilization, an approach has been developed for performing early comparisons of transportation architectures explicitly taking into account quantitative measures of uncertainty and resulting risk. The approach considers the uncertainty associated with the achievement of technology goals, the effect that the achieved level of technology will have on transportation system performance and the relationship between transportation system performance/capability and the ability to accommodate variations in payload mass. The consequences of system performance are developed in terms of expected values and associated standard deviations of nonrecurring, recurring and the present value of transportation system life cycle cost. Typical results are presented to illustrate the application of the methodology.

  12. 77 FR 75259 - Joint Report: Differences in Accounting and Capital Standards Among the Federal Banking Agencies...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-19

    ... consistent with U.S. generally accepted accounting principles. There were no significant differences in...] FEDERAL RESERVE SYSTEM FEDERAL DEPOSIT INSURANCE CORPORATION Joint Report: Differences in Accounting and... submit an annual report to the Committee on Financial Services of the U.S. House of Representatives and...

  13. DIFFERENCES IN THE STRUCTURE AND FUNCTION OF FATHEAD MINNOW AND HUMAN ERA: IMPLICATIONS FOR IN VITRO TESTING OF ENDOCRINE DISRUPTING CHEMICALS

    EPA Science Inventory

    Mammalian receptors and assay systems are generally used for in vitro analysis of endocrine disrupting chemicals (EDC) with the assumption that minor differences in amino acid sequences among species do not translate into significant differences in receptor function. We have fou...

  14. Improving the Quality of E-Learning: Lessons from the eMM

    ERIC Educational Resources Information Center

    Marshall, S.

    2012-01-01

    The quality of e-learning can be defined in many different ways, reflecting different stakeholders and the complexity of the systems and processes used in higher education. These different conceptions of quality can be mutually contradictory and, while politically significant, may also be beyond the direct control or influence of institutional…

  15. New insights into differences in brain organization between Neanderthals and anatomically modern humans

    PubMed Central

    Pearce, Eiluned; Stringer, Chris; Dunbar, R. I. M.

    2013-01-01

    Previous research has identified morphological differences between the brains of Neanderthals and anatomically modern humans (AMHs). However, studies using endocasts or the cranium itself are limited to investigating external surface features and the overall size and shape of the brain. A complementary approach uses comparative primate data to estimate the size of internal brain areas. Previous attempts to do this have generally assumed that identical total brain volumes imply identical internal organization. Here, we argue that, in the case of Neanderthals and AMHs, differences in the size of the body and visual system imply differences in organization between the same-sized brains of these two taxa. We show that Neanderthals had significantly larger visual systems than contemporary AMHs (indexed by orbital volume) and that when this, along with their greater body mass, is taken into account, Neanderthals have significantly smaller adjusted endocranial capacities than contemporary AMHs. We discuss possible implications of differing brain organization in terms of social cognition, and consider these in the context of differing abilities to cope with fluctuating resources and cultural maintenance. PMID:23486442

  16. Prognostic Impact of the 6th and 7th American Joint Committee on Cancer TNM Staging Systems on Esophageal Cancer Patients Treated With Chemoradiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nomura, Motoo, E-mail: excell@hkg.odn.ne.jp; Department of Radiation Oncology, Aichi Cancer Center Hospital; Shitara, Kohei

    2012-02-01

    Purpose: The new 7th edition of the American Joint Committee on Cancer TNM staging system is based on pathologic data from esophageal cancers treated by surgery alone. There is no information available on evaluation of the new staging system with regard to prognosis of patients treated with chemoradiotherapy (CRT). The objective of this study was to evaluate the prognostic impact of the new staging system on esophageal cancer patients treated with CRT. Methods and Materials: A retrospective review was performed on 301 consecutive esophageal squamous cell carcinoma patients treated with CRT. Comparisons were made of the prognostic impacts of themore » 6th and 7th staging systems and the prognostic impacts of stage and prognostic groups, which were newly defined in the 7th edition. Results: There were significant differences between Stages I and III (p < 0.01) according to both editions. However, the 7th edition poorly distinguishes the prognoses of Stages III and IV (p = 0.36 by multivariate analysis) in comparison to the 6th edition (p = 0.08 by multivariate analysis), although these differences were not significant. For all patients, T, M, and gender were independent prognostic factors by multivariate analysis (p < 0.05). For the Stage I and II prognostic groups, survival curves showed a stepwise decrease with increase in stage, except for Stage IIA. However, there were no significant differences seen between each prognostic stage. Conclusions: Our study indicates there are several problems with the 7th TNM staging system regarding prognostic factors in patients undergoing CRT.« less

  17. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems.

    PubMed

    Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Cavenago, Bruno Cavalini; Amoroso-Silva, Pablo Andrés; Bernardes, Ricardo Affonso; Vasconcelos, Bruno Carvalho de; Duarte, Marco Antonio Hungaro

    2017-01-01

    This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn's tests. For the comparison of data between groups, the Mann-Whitney test was used. In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  18. Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health

    PubMed Central

    Hersek, Sinan; Töreyin, Hakan; Teague, Caitlin N.; Millard-Stafford, Mindy L.; Jeong, Hyeon-Ki; Bavare, Miheer M.; Wolkoff, Paul; Sawka, Michael N.; Inan, Omer T.

    2017-01-01

    Objective We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Methods Five separate experiments were performed to demonstrate the: (1) ability of the EBI system to assess knee injury and recovery; (2) inter-day variability of knee EBI measurements; (3) sensitivity of the system to small changes in interstitial fluid volume; (4) reducing the error of EBI measurements using acceleration signals; (5) use of the system with dry electrodes integrated to a wearable knee wrap. Results (1) The absolute difference in resistance (R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p<0.05); the absolute difference in R decreased significantly (p<0.05) in injured subjects following rehabilitation. (2) The average inter-day variability (standard deviation) of the absolute difference in knee R was 2.5Ω, and for X was, 1.2 Ω. (3) Local heating/cooling resulted in a significant decrease/increase in knee R (p<0.01). (4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. (5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated (r2 = 0.8 and 0.9, respectively). Conclusion This work demonstrates the use of wearable EBI measurements in monitoring knee joint health. Significance The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation. PMID:28026745

  19. Transforming the Morbidity and Mortality Conference to Promote Safety and Quality in a PICU.

    PubMed

    Cifra, Christina L; Bembea, Melania M; Fackler, James C; Miller, Marlene R

    2016-01-01

    Determine the effectiveness of a structured systems-oriented morbidity and mortality conference in improving the process of reviewing and responding to adverse events in a PICU. Prospective time series analysis before and after implementation of a systems-oriented morbidity and mortality conference. Single tertiary referral PICU in Baltimore, MD. Thirty-three patients discussed before and 31 patients after implementation of a systems-oriented morbidity and mortality conference over a total of 20 morbidity and mortality conferences, from April 2013 to March 2014. Systems-oriented morbidity and mortality conference incorporating elements of medical incident analysis. There was a significant increase in meeting attendance (mean, 12 vs 31 attendees per morbidity and mortality conference; p < 0.001) after the systems-oriented morbidity and mortality conference was instituted. There was no significant difference in the mean number of cases suggested (4.2 vs 4.6) or discussed (3.3 vs 3.1) per morbidity and mortality conference. There was also no significant difference in the mean number of adverse events identified per morbidity and mortality conference (3.4 vs 4.3). However, there was an increase in the proportion of cases discussed using a standard case review tool, but this did not reach statistical significance (27% vs 45%; p = 0.231). Nevertheless, we observed a significant increase in the mean number of quality improvement interventions suggested (2.4 vs 5.6; p < 0.001) and implemented (1.7 vs 4.4; p < 0.001) per morbidity and mortality conference. All adverse event categories identified had corresponding interventions suggested after the systems-oriented morbidity and mortality conference was instituted compared with before (80% vs 100%). Intervention-to-adverse event ratios per category were also higher (mean, 0.6 vs 1.5). A structured systems-oriented PICU morbidity and mortality conference incorporating elements of medical incident analysis improves the process of reviewing and responding to adverse events by significantly increasing quality improvement interventions suggested and implemented. Future work would involve testing locally adapted versions of the systems-oriented morbidity and mortality conference in multiple inpatient settings.

  20. Ultrasonographic diagnosis of early pregnancy in cattle using different ultrasound systems.

    PubMed

    Racewicz, Przemysław; Sickinger, Marlene; Włodarek, Jan; Jaśkowski, Jędrzej M

    2016-06-16

    To evaluate the efficiency of different ultrasound devices in achieving an early diagnosis of pregnancy in dairy herds. A total of 1976 Holstein Friesian cows and heifers were artificially inseminated (AI) according to the herd manager's regime. Pregnancy diagnostics were performed between day 26 and 35 after AI using six different types of ultrasound systems (linear vs. sector scanners). Manual rectal palpation between day 45 and 60 after AI was used as the gold standard for pregnancy diagnostics. Sensitivity (SENS), specificity (SPEC), positive (PPV) and negative predictive value (NPV) and diagnostic accuracy (ACC) of the diagnostic measures were determined. Average SENS was 82% (range 67.7-95.2%) with a mean SPEC of 73% (range 50.0-81.0%). ACC was 78.2% with a minimum of 64.6% and a maximum of 89.4%, depending on the ultrasound system. The PPV (ratio of the number of pregnant cows with a positive examination result to the number of cows actually pregnant) was 80.8% (range 59.1-88.1%), whereas the NPV (defined as the ratio of the number of cows correctly diagnosed negative to the number of cows actually open) was 74.4% (72.3-91.9%). Significant differences for these parameters were found depending on the ultrasound system used (p ≤ 0.01; Cramer's V. = 0.14). Regardless of the ultrasound device used, early pregnancy diagnostics between day 26 and 35 show a moderate diagnostic efficiency. Comparing the accuracy of the different devices, there may be a significant influence of type and technical parameters. Even though ultrasound systems with mechanical sector probes are not as convenient to use as systems with linear probes, according to this study, sector scanners are a reasonable alternative.

  1. Different computer-assisted sperm analysis (CASA) systems highly influence sperm motility parameters.

    PubMed

    Boryshpolets, S; Kowalski, R K; Dietrich, G J; Dzyuba, B; Ciereszko, A

    2013-10-15

    In this study, we examined different computer-assisted sperm analysis (CASA) systems (CRISMAS, Hobson Sperm Tracker, and Image J CASA) on the exact same video recordings to evaluate the differences in sperm motility parameters related to the specific CASA used. To cover a wide range of sperm motility parameters, we chose 12-second video recordings at 25 and 50 Hz frame rates after sperm motility activation using three taxonomically distinct fish species (sterlet: Acipenser ruthenus L.; common carp: Cyprinus carpio L.; and rainbow trout: Oncorhynchus mykiss Walbaum) that are characterized by essential differences in sperm behavior during motility. Systematically higher values of velocity and beat cross frequency (BCF) were observed in video recordings obtained at 50 Hz frame frequency compared with 25 Hz for all three systems. Motility parameters were affected by the CASA and species used for analyses. Image J and CRISMAS calculated higher curvilinear velocity (VCL) values for rainbow trout and common carp at 25 Hz frequency compared with the Hobson Sperm Tracker, whereas at 50 Hz, a significant difference was observed only for rainbow trout sperm recordings. No significant difference was observed between the CASA systems for sterlet sperm motility at 25 and 50 Hz. Additional analysis of 1-second segments taken at three time points (1, 6, and 12 seconds of the recording) revealed a dramatic decrease in common carp and rainbow trout sperm speed. The motility parameters of sterlet spermatozoa did not change significantly during the 12-second motility period and should be considered as a suitable model for longer motility analyses. Our results indicated that the CASA used can affect motility results even when the same motility recordings are used. These results could be critically altered by the recording quality, time of analysis, and frame rate of camera, and could result in erroneous conclusions. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Structure of force networks in tapped particulate systems of disks and pentagons. II. Persistence analysis.

    PubMed

    Kondic, L; Kramár, M; Pugnaloni, Luis A; Carlevaro, C Manuel; Mischaikow, K

    2016-06-01

    In the companion paper [Pugnaloni et al., Phys. Rev. E 93, 062902 (2016)10.1103/PhysRevE.93.062902], we use classical measures based on force probability density functions (PDFs), as well as Betti numbers (quantifying the number of components, related to force chains, and loops), to describe the force networks in tapped systems of disks and pentagons. In the present work, we focus on the use of persistence analysis, which allows us to describe these networks in much more detail. This approach allows us not only to describe but also to quantify the differences between the force networks in different realizations of a system, in different parts of the considered domain, or in different systems. We show that persistence analysis clearly distinguishes the systems that are very difficult or impossible to differentiate using other means. One important finding is that the differences in force networks between disks and pentagons are most apparent when loops are considered: the quantities describing properties of the loops may differ significantly even if other measures (properties of components, Betti numbers, force PDFs, or the stress tensor) do not distinguish clearly or at all the investigated systems.

  3. Effect of egg freshness on texture and baking characteristics of batter systems formulated using egg, flour and sugar.

    PubMed

    Xing, Liting; Niu, Fuge; Su, Yujie; Yang, Yanjun

    2016-04-01

    The aim of this work was to evaluate the effects of egg freshness on baking properties and final qualities in batter systems. Batters were made with eggs of different freshness, and the properties of batter systems were studied through rheological analysis, rapid viscosity analysis (RVA), differential scanning calorimetry (DSC), batter density and expansion rate during the baking and cooling processes. Moreover, the qualities of final baked systems were investigated, including specific volume and texture profile analysis (TPA). The flow behavior of batters showed that the consistency index (K) decreased as the Haugh unit (HU) value decreased, while the flow behavior index (n) increased. Both the storage modulus (G') and loss modulus (G″) determined by mechanical spectra at 20 °C decreased with decreasing HU. RVA and DSC determinations revealed that lower-HU samples had a lower viscosity in the baking process and a shorter time for starch gelatinization and egg protein denaturation. Observation of the batter density revealed an increasing change, which was reflected by a decrease in the specific volume of final models. TPA showed significant differences in hardness and chewiness, but no significant differences in springiness and cohesiveness were found. The egg freshness affected the properties of batter systems. © 2015 Society of Chemical Industry.

  4. Speech Understanding with a New Implant Technology: A Comparative Study with a New Nonskin Penetrating Baha System

    PubMed Central

    Caversaccio, Marco

    2014-01-01

    Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found. PMID:25140314

  5. The endogenous opioid system: a common substrate in drug addiction.

    PubMed

    Trigo, José Manuel; Martin-García, Elena; Berrendero, Fernando; Robledo, Patricia; Maldonado, Rafael

    2010-05-01

    Drug addiction is a chronic brain disorder leading to complex adaptive changes within the brain reward circuits that involve several neurotransmitters. One of the neurochemical systems that plays a pivotal role in different aspects of addiction is the endogenous opioid system (EOS). Opioid receptors and endogenous opioid peptides are largely distributed in the mesolimbic system and modulate dopaminergic activity within these reward circuits. Chronic exposure to the different prototypical drugs of abuse, including opioids, alcohol, nicotine, psychostimulants and cannabinoids has been reported to produce significant alterations within the EOS, which seem to play an important role in the development of the addictive process. In this review, we will describe the adaptive changes produced by different drugs of abuse on the EOS, and the current knowledge about the contribution of each component of this neurobiological system to their addictive properties.

  6. Cultural beliefs and teenage pregnancy.

    PubMed

    Horn, B

    1983-09-01

    The influence of cultural variables on teenage pregnancy is not clearly understood. In-depth interviews with 20 Native American Indian, 17 black and 18 white teenage women indicated intercultural differences in beliefs about: (1) prevention of pregnancy, (2) significance of becoming a mother at an early age and (3) kinds of support systems available to them within their social network. The implications of these differences for nursing care include recognition and acceptance of intercultural differences and support of a decision-making model of pregnancy prevention for teenagers that incorporates diverse belief systems.

  7. Y-MP floating point and Cholesky factorization

    NASA Technical Reports Server (NTRS)

    Carter, Russell

    1991-01-01

    The floating point arithmetics implemented in the Cray 2 and Cray Y-MP computer systems are nearly identical, but large scale computations performed on the two systems have exhibited significant differences in accuracy. The difference in accuracy is analyzed for Cholesky factorization algorithm, and it is found that the source of the difference is the subtract magnitude operation of the Cray Y-MP. The results from numerical experiments for a range of problem sizes are presented, and an efficient method for improving the accuracy of the factorization obtained on the Y-MP is presented.

  8. Morphological changes on development of Tenebrio molitor L. (Coleoptera: Tenebrionidae) in rearing room system, free air CO2 enrichment system and open roof ventilation system

    NASA Astrophysics Data System (ADS)

    Ramli, Nur Hasyimah; Yaakop, Salmah

    2018-04-01

    Tenebrio molitor known as darkling beetle is burrowing insects and can be found all over the world. Tenebrio molitor samples were put in Open Roof Ventilation System, Free Air CO2 Enrichment and Rearing Room system. The development of Tenebrio molitor adult parents (P) and first generation (F1) that more exposed to high level of CO2 were studied. As the results, parent and first generation (F1) of T. molitor shows that there are no significant effects of CO2 on their development. But, decreased development pattern showed between parent and F1 can be used to estimate that prolonged exposure of CO2 will change their development. The highest development of parent showed by OFVSP (0.1708±0.0013) mm, while the lowest showed by FACEP (0.1686±0.0013) mm. For F1, the highest development showed by OFVS F1 (0.1705±0.0015) mm, while RR F1 becomes the lowest (0.1649±0.0023) mm. No significant difference shown by ANOVA test. Unfortunately, the data cannot be used to prove that the development of parent and F1 were affected by CO2 because no significant difference recorded between them. Correlation coefficient analysis of OFVSP and OFVS F1 presented to support the results. It shows that the correlation coefficient among characters from parents and F1 are different. Further study should be done in future to increase our knowledge of the climate change on insects.

  9. [Effects of long-term fertilization on pH buffer system of sandy loam calcareous fluvor-aquic soil].

    PubMed

    Wang, Ji-Dong; Qi, Bing-Jie; Zhang, Yong-Chun; Zhang, Ai-Jun; Ning, Yun-Wang; Xu, Xian-Ju; Zhang, Hui; Ma, Hong-Bo

    2012-04-01

    Soil samples (0-80 cm) were collected from a 30-year fertilization experimental site in Xuzhou, Jiangsu Province of East China to study the variations of the pH, calcium carbonate and active calcium carbonate contents, and pH buffer capacity of sandy loam calcareous fluvor-aquic soil under different fertilization treatments. Thirty-year continuous application of different fertilizers accelerated the acidification of topsoil (0-20 cm), with the soil pH decreased by 0.41-0.70. Under different fertilization, the soil pH buffer capacity (pHBC) varied from 15.82 to 21.96 cmol x kg(-1). As compared with no fertilization, single N fertilization decreased the pHBC significantly, but N fertilization combined with organic fertilization could significantly increase the pHBC. The soil pHBC had significant positive correlations with soil calcium carbonate and active calcium carbonate contents, but less correlation with soil organic matter content and soil cation exchange capacity, suggesting that after a long-term fertilization, the sandy loam calcareous fluvor-aquic soil was still of an elementary calcium carbonate buffer system, and soil organic matter and cation exchange capacity contributed little to the buffer system. The soil calcium carbonate and active calcium carbonate contents were greater in 0-40 cm than in 40-80 cm soil layer. Comparing with soil calcium carbonate, soil active calcium carbonate was more sensitive to reflect the changes of soil physical and chemical properties, suggesting that the calcium carbonate buffer system could be further classified as soil active calcium carbonate buffer system.

  10. Solar- and wind-powered irrigation systems

    NASA Astrophysics Data System (ADS)

    Enochian, R. V.

    1982-02-01

    Five different direct solar and wind energy systems are technically feasible for powering irrigation pumps. However, with projected rates of fossil fuel costs, only two may produce significant unsubsidied energy for irrigation pumping before the turn of the century. These are photovoltaic systems with nonconcentrating collectors (providing that projected costs of manufacturing solar cells prove correct); and wind systems, especially in remote areas where adequate wind is available.

  11. Balance, Proprioception, and Gross Motor Development of Chinese Children Aged 3 to 6 Years.

    PubMed

    Jiang, Gui-Ping; Jiao, Xi-Bian; Wu, Sheng-Kou; Ji, Zhong-Qiu; Liu, Wei-Tong; Chen, Xi; Wang, Hui-Hui

    2018-01-01

    The authors' aim was to find the features of balance, proprioception, and gross motor development of Chinese children 3-6 years old and their correlations, provide theoretical support for promoting children's motor development, and enrich the world theoretical system of motor development. This study used a Tekscan foot pressure measurement instrument (Tekscan, Inc., Boston, MA), walking on a balance beam, Xsens 3-dimensional positional measuring system (Xsens Technologies, Enschede, the Netherlands), and Test of Gross Motor Development-2 to assess static balance, dynamic balance, knee proprioception, and levels of gross motor development (GMD) of 3- to 6-year-old children (n = 60) in Beijing. The results are as follows: children had significant age differences in static balance, dynamic balance, proprioception, and levels of GMD; children had significant gender differences in static balance, proprioception, and levels of GMD; children's static balance, dynamic balance, and proprioception had a very significant positive correlation with GMD (p < .01), but no significant correlation with body mass index.

  12. A genotoxic analysis of the hematopoietic system after mobile phone type radiation exposure in rats.

    PubMed

    Kumar, Gaurav; McIntosh, Robert L; Anderson, Vitas; McKenzie, Ray J; Wood, Andrew W

    2015-08-01

    In our earlier study we reported that 900 MHz continuous wave (CW) radiofrequency radiation (RFR) exposure (2 W/kg specific absorption rate [SAR]) had no significant effect on the hematopoietic system of rats. In this paper we extend the scope of the previous study by testing for possible effects at: (i) different SAR levels; (ii) both 900 and 1800 MHz, and; (iii) both CW and pulse modulated (PM) RFR. Excised long bones from rats were placed in medium and RFR exposed in (i) a Transverse Electromagnetic (TEM) cell or (ii) a waveguide. Finite-difference time-domain (FDTD) numerical analyses were used to estimate forward power needed to produce nominal SAR levels of 2/10 and 2.5/12.4 W/kg in the bone marrow. After exposure, the lymphoblasts were extracted and assayed for proliferation rate, and genotoxicity. Our data did not indicate any significant change in these end points for any combination of CW/PM exposure at 900/1800 MHz at SAR levels of nominally 2/10 W/kg or 2.5/12.4 W/kg. No significant changes were observed in the hematopoietic system of rats after the exposure of CW/PM wave 900 MHz/1800 MHz RF radiations at different SAR values.

  13. Culture medium composition affects the gene expression pattern and in vitro development potential of bovine somatic cell nuclear transfer (SCNT) embryos.

    PubMed

    Arias, María E; Ross, Pablo J; Felmer, Ricardo N

    2013-01-01

    Different culture systems have been studied that support development of somatic cell nuclear transfer (SCNT) embryos up to the blastocyst stage. However, the use of sequential and two-step culture systems has been less studied. The objective of the present study was to examine the developmental potential and quality of bovine SCNT embryos cultured in different two-step culture media based on KSOM, SOF and the macromolecules FBS and BSA (K-K/FBS, K-S/BSA and K-K/BSA, respectively). No differences were observed in the cleavage rate for any of the culture systems. However, there was a significant difference (P<0.01) in the rate of blastocyst development, with the K-K/ FBS culture system yielding a higher rate of blastocysts (28%) compared to other treatments (18 and 15%, for K-S/BSA and K-K/BSA, respectively). Although quality of embryos, as assessed by the total number of cells, was not different, the apoptosis index was significantly affected in the sequential culture system (K-S/BSA). Gene expression analysis showed alterations of DNMT1, IGF2, LIF, and PRDX6 genes in embryos cultured in K-S/FBS and of SOD2 in embryos cultured in K-K/BSA. In conclusion, we demonstrated that culture medium may affect not only the developmental potential of SCNT embryos but also, more importantly, the gene expression pattern and apoptotic index, presenting the possibility to manipulate the culture medium composition to modulate global gene expression and improve the overall efficiency of this technique.

  14. Shaping Ability of Single-file Systems with Different Movements: A Micro-computed Tomographic Study.

    PubMed

    Santa-Rosa, Joedy; de Sousa-Neto, Manoel Damião; Versiani, Marco Aurelio; Nevares, Giselle; Xavier, Felipe; Romeiro, Kaline; Cassimiro, Marcely; Leoni, Graziela Bianchi; de Menezes, Rebeca Ferraz; Albuquerque, Diana

    2016-01-01

    This study aimed to perform a rigorous sample standardization and also evaluate the preparation of mesiobuccal (MB) root canals of maxillary molars with severe curvatures using two single-file engine-driven systems (WaveOne with reciprocating motion and OneShape with rotary movement), using micro-computed tomography (micro-CT). Ten MB roots with single canals were included, uniformly distributed into two groups (n=5). The samples were prepared with a WaveOne or OneShape files. The shaping ability and amount of canal transportation were assessed by a comparison of the pre- and post-instrumentation micro-CT scans. The Kolmogorov-Smirnov and t-tests were used for statistical analysis. The level of significance was set at 0.05. Instrumentation of canals increased their surface area and volume. Canal transportation occurred in coronal, middle and apical thirds and no statistical difference was observed between the two systems (P>0.05). In apical third, significant differences were found between groups in canal roundness (in 3 mm level) and perimeter (in 3 and 4 mm levels) (P<0.05). The WaveOne and One Shape single-file systems were able to shape curved root canals, producing minor changes in the canal curvature.

  15. A Thermal Physiological Comparison of Two HazMat Protective Ensembles With and Without Active Convective Cooling

    NASA Technical Reports Server (NTRS)

    Williamson, Rebecca; Carbo, Jorge; Luna, Bernadette; Webbon, Bruce W.

    1998-01-01

    Wearing impermeable garments for hazardous materials clean up can often present a health and safety problem for the wearer. Even short duration clean up activities can produce heat stress injuries in hazardous materials workers. It was hypothesized that an internal cooling system might increase worker productivity and decrease likelihood of heat stress injuries in typical HazMat operations. Two HazMat protective ensembles were compared during treadmill exercise. The different ensembles were created using two different suits: a Trelleborg VPS suit representative of current HazMat suits and a prototype suit developed by NASA engineers. The two life support systems used were a current technology Interspiro Spirolite breathing apparatus and a liquid air breathing system that also provided convective cooling. Twelve local members of a HazMat team served as test subjects. They were fully instrumented to allow a complete physiological comparison of their thermal responses to the different ensembles. Results showed that cooling from the liquid air system significantly decreased thermal stress. The results of the subjective evaluations of new design features in the prototype suit were also highly favorable. Incorporation of these new design features could lead to significant operational advantages in the future.

  16. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System

    PubMed Central

    Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael

    2015-01-01

    Objectives MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Methods Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators – attending (AR) and resident radiologists (RR) as well as medical students (MS) – performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Results Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). Conclusions The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were significant differences in experimental procedure times but not in the number of successful biopsies. PMID:26222443

  17. Impact of physiological, physicochemical and biopharmaceutical factors in absorption and metabolism mechanisms on the drug oral bioavailability of rats and humans.

    PubMed

    Hurst, Susan; Loi, Cho-Ming; Brodfuehrer, Joanne; El-Kattan, Ayman

    2007-08-01

    The onset, intensity and duration of therapeutic response to a compound depend on the intrinsic pharmacological activity of the drug and pharmacokinetic factors related to its absorption, distribution, metabolism and elimination that are inherent to the biological system. The process of drug transfer from the site of administration to the systemic circulation and the interspecies factors that impact this process are the scope of this review. In general, the factors that influence oral drug bioavailability via absorption and metabolism can be divided into physicochemical/biopharmaceutical and physiological factors. Physicochemical and biopharmaceutical factors that influence permeability and solubility tend to be species independent. Although there are significant differences in the anatomy and physiology of the gastrointestinal tract, these are not associated with significant differences in the rate and extent of drug absorption between rats and humans. However, species differences in drug metabolism in rats and humans did result in significant species differences in bioavailability. Overall, this review provides a better understanding of the interplay between drug physicochemical/biopharmaceutical factors and species differences/similarities in the absorption and metabolism mechanisms that affect oral bioavailability in rats and humans. This will enable a more rational approach to perform projection of oral bioavailability in human using available rat in vivo data.

  18. Multicenter study of quantitative computed tomography analysis using a computer-aided three-dimensional system in patients with idiopathic pulmonary fibrosis.

    PubMed

    Iwasawa, Tae; Kanauchi, Tetsu; Hoshi, Toshiko; Ogura, Takashi; Baba, Tomohisa; Gotoh, Toshiyuki; Oba, Mari S

    2016-01-01

    To evaluate the feasibility of automated quantitative analysis with a three-dimensional (3D) computer-aided system (i.e., Gaussian histogram normalized correlation, GHNC) of computed tomography (CT) images from different scanners. Each institution's review board approved the research protocol. Informed patient consent was not required. The participants in this multicenter prospective study were 80 patients (65 men, 15 women) with idiopathic pulmonary fibrosis. Their mean age was 70.6 years. Computed tomography (CT) images were obtained by four different scanners set at different exposures. We measured the extent of fibrosis using GHNC, and used Pearson's correlation analysis, Bland-Altman plots, and kappa analysis to directly compare the GHNC results with manual scoring by radiologists. Multiple linear regression analysis was performed to determine the association between the CT data and forced vital capacity (FVC). For each scanner, the extent of fibrosis as determined by GHNC was significantly correlated with the radiologists' score. In multivariate analysis, the extent of fibrosis as determined by GHNC was significantly correlated with FVC (p < 0.001). There was no significant difference between the results obtained using different CT scanners. Gaussian histogram normalized correlation was feasible, irrespective of the type of CT scanner used.

  19. Ceramic materials for porcelain veneers: part II. Effect of material, shade, and thickness on translucency.

    PubMed

    Barizon, Karine T L; Bergeron, Cathia; Vargas, Marcos A; Qian, Fang; Cobb, Deborah S; Gratton, David G; Geraldeli, Saulo

    2014-10-01

    Information regarding the differences in translucency among new ceramic systems is lacking. The purpose of this study was to compare the relative translucency of the different types of ceramic systems indicated for porcelain veneers and to evaluate the effect of shade and thickness on translucency. Disk specimens 13 mm in diameter and 0.7-mm thick were fabricated for the following 9 materials (n=5): VITA VM9, IPS Empress Esthetic, VITA PM9, Vitablocks Mark II, Kavo Everest G-Blank, IPS Empress CAD, IPS e.max CAD, IPS e.maxPress, and Lava Zirconia. VITA VM9 served as the positive control and Lava as the negative control. The disks were fabricated with the shade that corresponds to A1. For IPS e.maxPress, additional disks were made with different shades (BL2, BL4, A1, B1, O1, O2, V1, V2, V3), thickness (0.3 mm), and translucencies (high translucency, low translucency). Color coordinates (CIE L∗ a∗ b∗) were measured with a tristimulus colorimeter. The translucency parameter was calculated from the color difference of the material on a black versus a white background. One-way ANOVA, the post hoc Tukey honestly significant difference, and the Ryan-Einot-Gabriel-Welsch multiple range tests were used to analyze the data (α=.05). Statistically significant differences in the translucency parameter were found among porcelains (P<.001) according to the following rank: VM9>PM9, Empress Esthetic>Empress CAD>Mark II, Everest, e.max CAD>e.max Press>Lava. Significant differences also were noted when different shades and thickness were compared (P<.001). Different ceramic systems designed for porcelain veneers present varying degrees of translucency. The thickness and shade of lithium disilicate ceramic affect its translucency. Shade affects translucency parameter less than thickness. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. [Main interspecific competition and land productivity of fruit-crop intercropping in Loess Region of West Shauxi].

    PubMed

    Yun, Lei; Bi, Hua-Xing; Tian, Xiao-Ling; Cui, Zhe-Wei; Zhou, Hui-Zi; Gao, Lu-Bo; Liu, Li-Xia

    2011-05-01

    Taking the four typical fruit-crop intercropping models, i.e., walnut-peanut, walnut-soybean, apple-peanut, and apple-soybean, in the Loess Region of western Shanxi Province as the objects, this paper analyzed the crop (peanut and soybean) photosynthetic active radiation (PAR), net photosynthetic rate (P(n)), yield, and soil moisture content. Comparing with crop monoculture, fruit-crop intercropping decreased the crop PAR and P(n). The smaller the distance from tree rows, the smaller the crop PAR and P(n). There was a significantly positive correlation between the P(n) and crop yield, suggesting that illumination was one of the key factors affecting crop yield. From the whole trend, the 0-100 cm soil moisture content had no significant differences between walnut-crop intercropping systems and corresponding monoculture cropping systems, but had significant differences between apple-crop intercropping systems and corresponding monoculture cropping systems, indicating that the competition for soil moisture was more intense in apple-crop intercropping systems than in walnut-crop intercropping systems. Comparing with monoculture, fruit-crop intercropping increased the land use efficiency and economic benefit averagely by 70% and 14%, respectively, and walnut-crop intercropping was much better than apple-crop intercropping. To increase the crop yield in fruit-crop intercropping systems, the following strategies should be taken: strengthening the management of irrigation and fertilization, increasing the distances or setting root barriers between crop and tree rows, regularly and properly pruning, and planting shade-tolerant crops in intercropping.

  1. The relationship between race, cigarette smoking and carotid intimal medial thickness in systemic lupus erythematosus.

    PubMed

    Scalzi, L V; Bhatt, S; Gilkeson, R C; Shaffer, M L

    2009-12-01

    Racial differences are known to account for a higher incidence of systemic lupus erythematosus (SLE), as well as increased disease severity and mortality. The purpose of this study was to determine whether there are any race-specific risk factors that affect measures of subclinical atherosclerosis in SLE patients. Traditional and SLE-related cardiovascular disease (CVD) risk factors were assessed in 106 female SLE patients. Carotid medial intimal medial thickness (mIMT) and coronary artery calcification (CAC) were measured on all subjects. Differences were evaluated between races for all clinical, serologic, and CVD risk factors and the racial interactions with all covariables. Outcomes included mIMT and CAC. There were no significant differences between races with regard to mIMT or CAC. Significant covariables in the final model for mIMT included age, triglycerides, glucose, and race-age and race-smoking interactions. A prediction model with fixed significant covariables demonstrated that Black subjects with a smoking history had a significantly higher mIMT than Blacks who had never smoked, an effect not seen in Whites. There were no differences between having CAC or with the CAC scores between the races. In the final model for CAC, age and SLE disease duration were significant covariables impacting CAC. When controlling for other significant CVD covariables and interactions, Black women, but not White, with SLE with a history of smoking have higher mIMT measurements than those who have never smoked. This is the first report documenting the race-specific effect of smoking on subclinical measures of CVD in SLE.

  2. Multi-modal demands of a smartphone used to place calls and enter addresses during highway driving relative to two embedded systems

    PubMed Central

    Reimer, Bryan; Mehler, Bruce; Reagan, Ian; Kidd, David; Dobres, Jonathan

    2016-01-01

    Abstract There is limited research on trade-offs in demand between manual and voice interfaces of embedded and portable technologies. Mehler et al. identified differences in driving performance, visual engagement and workload between two contrasting embedded vehicle system designs (Chevrolet MyLink and Volvo Sensus). The current study extends this work by comparing these embedded systems with a smartphone (Samsung Galaxy S4). None of the voice interfaces eliminated visual demand. Relative to placing calls manually, both embedded voice interfaces resulted in less eyes-off-road time than the smartphone. Errors were most frequent when calling contacts using the smartphone. The smartphone and MyLink allowed addresses to be entered using compound voice commands resulting in shorter eyes-off-road time compared with the menu-based Sensus but with many more errors. Driving performance and physiological measures indicated increased demand when performing secondary tasks relative to ‘just driving’, but were not significantly different between the smartphone and embedded systems. Practitioner Summary: The findings show that embedded system and portable device voice interfaces place fewer visual demands on the driver than manual interfaces, but they also underscore how differences in system designs can significantly affect not only the demands placed on drivers, but also the successful completion of tasks. PMID:27110964

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berrada, K., E-mail: kberrada@ictp.it; The Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Miramare-Trieste; Ooi, C. H. Raymond

    Robustness of the geometric phase (GP) with respect to different noise effects is a basic condition for an effective quantum computation. Here, we propose a useful quantum system with real physical parameters by studying the GP of a pair of Stokes and anti-Stokes photons, involving Raman emission processes with and without photonic band gap (PBG) effect. We show that the properties of GP are very sensitive to the change of the Rabi frequency and time, exhibiting collapse phenomenon as the time becomes significantly large. The system allows us to obtain a state which remains with zero GP for longer times.more » This result plays a significant role to enhance the stabilization and control of the system dynamics. Finally, we investigate the nonlocal correlation (entanglement) between the pair photons by taking into account the effect of different parameters. An interesting correlation between the GP and entanglement is observed showing that the PBG stabilizes the fluctuations in the system and makes the entanglement more robust against the change of time and frequency.« less

  4. The evolution of locomotor rhythmicity in tetrapods.

    PubMed

    Ross, Callum F; Blob, Richard W; Carrier, David R; Daley, Monica A; Deban, Stephen M; Demes, Brigitte; Gripper, Janaya L; Iriarte-Diaz, Jose; Kilbourne, Brandon M; Landberg, Tobias; Polk, John D; Schilling, Nadja; Vanhooydonck, Bieke

    2013-04-01

    Differences in rhythmicity (relative variance in cycle period) among mammal, fish, and lizard feeding systems have been hypothesized to be associated with differences in their sensorimotor control systems. We tested this hypothesis by examining whether the locomotion of tachymetabolic tetrapods (birds and mammals) is more rhythmic than that of bradymetabolic tetrapods (lizards, alligators, turtles, salamanders). Species averages of intraindividual coefficients of variation in cycle period were compared while controlling for gait and substrate. Variance in locomotor cycle periods is significantly lower in tachymetabolic than in bradymetabolic animals for datasets that include treadmill locomotion, non-treadmill locomotion, or both. When phylogenetic relationships are taken into account the pooled analyses remain significant, whereas the non-treadmill and the treadmill analyses become nonsignificant. The co-occurrence of relatively high rhythmicity in both feeding and locomotor systems of tachymetabolic tetrapods suggests that the anatomical substrate of rhythmicity is in the motor control system, not in the musculoskeletal components. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.

  5. Composting of high moisture content swine manure with corncob in a pilot-scale aerated static bin system.

    PubMed

    Zhu, Nengwu

    2006-10-01

    Pilot composting experiments of swine manure with corncob were conducted to evaluate the performance of the aerated static bin composting system. Effects of temperature control (60 and 70 degrees C) and moisture content (70% and 80%) were monitored on the composting by measuring physical and chemical indexes. The results showed that (1) the composting system could destroy pathogens, converted nitrogen from unstable ammonia to stable organic forms, and reduced the volume of waste; (2) significant difference of NH(4)(+)-N (P(12) = 0.074), and (NO(3)(-) + NO(2)(-))-N (P(12) = 0.085) was found between the temperature control treatments; (3) anaerobic reaction in the treatment with 80% moisture content resulted in significant difference of pH (P(23) = 0.006), total organic matter (P(23) = 0.003), and germination index (P(23) = 0.040) between 70% and 80%. Therefore, the optimum initial moisture content was less than 80% with the composting of swine manure and corncob by using the composting system.

  6. Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

    PubMed

    Carvalho, Maira de Souza; Junior, Emílio Carlos Sponchiado; Bitencourt Garrido, Angela Delfina; Roberti Garcia, Lucas da Fonseca; Franco Marques, André Augusto

    2015-01-01

    The aim of this study was to evaluate the cleaning effectiveness achieved with two reciprocating single-file systems in severely curved root canals: Reciproc and WaveOne. Twenty-five mesial roots of mandibular molars were randomly separated into two groups, according to the instrumentation system used. The negative control group consisted of five specimens that were not instrumented. The mesial canals (buccal and lingual) in Reciproc Group were instrumented with file R25 and the WaveOne group with the Primary file. The samples were submitted to histological processing and analyzed under a digital microscope. The WaveOne group presented a larger amount of debris than the Reciproc Group, however, without statistically significant difference (P > 0.05). A larger amount of debris in the control group was observed, with statistically significant difference to Reciproc and WaveOne groups (P < 0.05). The two reciprocating single-file instrumentation systems presented similar effectiveness for root canal cleaning.

  7. Discrete dynamical system modelling for gene regulatory networks of 5-hydroxymethylfurfural tolerance for ethanologenic yeast.

    PubMed

    Song, M; Ouyang, Z; Liu, Z L

    2009-05-01

    Composed of linear difference equations, a discrete dynamical system (DDS) model was designed to reconstruct transcriptional regulations in gene regulatory networks (GRNs) for ethanologenic yeast Saccharomyces cerevisiae in response to 5-hydroxymethylfurfural (HMF), a bioethanol conversion inhibitor. The modelling aims at identification of a system of linear difference equations to represent temporal interactions among significantly expressed genes. Power stability is imposed on a system model under the normal condition in the absence of the inhibitor. Non-uniform sampling, typical in a time-course experimental design, is addressed by a log-time domain interpolation. A statistically significant DDS model of the yeast GRN derived from time-course gene expression measurements by exposure to HMF, revealed several verified transcriptional regulation events. These events implicate Yap1 and Pdr3, transcription factors consistently known for their regulatory roles by other studies or postulated by independent sequence motif analysis, suggesting their involvement in yeast tolerance and detoxification of the inhibitor.

  8. Mechanical performance of encapsulated restorative glass-ionomer cements for use with Atraumatic Restorative Treatment (ART).

    PubMed

    Molina, Gustavo Fabián; Cabral, Ricardo Juan; Mazzola, Ignacio; Lascano, Laura Brain; Frencken, Jo E

    2013-01-01

    The Atraumatic Restorative Treatment (ART) approach was suggested to be a suitable method to treat enamel and dentine carious lesions in patients with disabilities. The use of a restorative glass-ionomer with optimal mechanical properties is, therefore, very important. To test the null-hypotheses that no difference in diametral tensile, compressive and flexural strengths exists between: (1) The EQUIA system and (2) The Chemfil Rock (encapsulated glass-ionomers; test materials) and the Fuji 9 Gold Label and the Ketac Molar Easymix (hand-mixed conventional glass-ionomers; control materials); (3) The EQUIA system and Chemfil Rock. Specimens for testing flexural (n = 240) and diametral tensile (n=80) strengths were prepared according to standardized specifications; the compressive strength (n=80) was measured using a tooth-model of a class II ART restoration. ANOVA and Tukey B tests were used to test for significant differences between dependent and independent variables. The EQUIA system and Chemfil Rock had significantly higher mean scores for all the three strength variables than the Fuji 9 Gold Label and Ketac Molar Easymix (α=0.05). The EQUIA system had significant higher mean scores for diametral tensile and flexural strengths than the Chemfil Rock (α=0.05). The two encapsulated high-viscosity glass-ionomers had significantly higher test values for diametral tensile, flexural and compressive strengths than the commonly used hand-mixed high-viscosity glass-ionomers.

  9. Effects of instrumentation time on microleakage of resin-modified glass ionomer cements.

    PubMed

    Yap, Adrian U J; Yeo, Egwin J C; Yap, W Y; Ong, Debbie S B; Tan, Jane W S

    2003-01-01

    This study investigated the effect of instrumentation time on the microleakage of resin-modified glass ionomer cements (RMGICs). Class V cavities were prepared on buccal and lingual/ palatal surfaces of 64 freshly extracted non-carious premolars. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]). The restored teeth were randomly divided into two groups of 32 teeth. Finishing/polishing was done immediately after light-polymerization in one group and was delayed for one week in the other group. The following finishing/polishing systems were evaluated: (a) Robot Carbides (RC); (b) SuperSnap (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each instrumentation time, material and finishing/polishing system combination was 8. Storage medium for both immediate and delayed instrumentation groups was distilled water at 37 degrees C during the hiatus period. The teeth were subsequently subjected to dye penetration testing (0.5% basic fushcin), sectioned and scored. Data were analyzed using Kruskal-Wallis and Mann-Whitney U tests at significance level 0.05. For PF, significant difference in enamel leakage was observed between immediate and delayed instrumentation with SS and CS. Significant differences in dentin leakage were also observed between the two instrumentation times for SS. For FT, significant differences in leakage between instrumentation times were observed only in dentin and with RC. Where significant differences in dye penetration scores existed, delayed finishing/polishing resulted in less microleakage.

  10. Cerebrospinal Fluid Cytokine Expression Profile in Multiple Sclerosis and Chronic Inflammatory Demyelinating Polyneuropathy.

    PubMed

    Bonin, Serena; Zanotta, Nunzia; Sartori, Arianna; Bratina, Alessio; Manganotti, Paolo; Trevisan, Giusto; Comar, Manola

    2018-02-01

    Cerebrospinal fluid (CSF) analysis in patients with particular neurologic disorders is a powerful tool to evaluate specific central nervous system inflammatory markers for diagnostic needs, because CSF represents the specific immune micro-environment to the central nervous system. CSF samples from 49 patients with multiple sclerosis (MS), chronic inflammatory demyelinating polyneuropathy (CIDP), and non-inflammatory neurologic disorders (NIND) as controls were submitted to protein expression profiles of 47 inflammatory biomarkers by multiplex Luminex bead assay to investigate possible differences in the inflammatory process for MS and CIDP. Our results showed differences in CSF cytokine levels in MS and CIDP; in particular, IL12 (p40) was significantly highly expressed in MS in comparison with CIDP and NIND, while SDF-1α and SCGF-β were significantly highly expressed in CIDP cohort when compared to MS and NIND. IL-9, IL-13, and IL-17 had higher expression levels in NIND if compared with the other groups. Our study showed that, despite some common pathogenic mechanisms, central and peripheral nervous system demyelinating diseases, such as MS and CIDP, differ in some specific inflammatory soluble proteins in CSF, underlining differences in the immune response involved in those autoimmune diseases.

  11. Reducing the standard deviation in multiple-assay experiments where the variation matters but the absolute value does not.

    PubMed

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A

    2013-01-01

    When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.

  12. Heart rate variability changes during stroop color and word test among genders.

    PubMed

    Satish, Priyanka; Muralikrishnan, Krishnan; Balasubramanian, Kabali; Shanmugapriya

    2015-01-01

    Stress is the reaction of the body to a change that requires physical, mental or emotional adjustments. Individual differences in stress reactivity are a potentially important risk factor for gender-specific health problems in men and women. The Autonomic regulation of the cardiovascular system is most commonly affected by stress and is assessed by means of short term heart rate variability (HRV).The present study was undertaken to investigate the difference in the cardiovascular Autonomic Nervous System response to mental stress between the genders using HRV as tool. We compared the mean RR interval, Blood pressure and indices of HRV during the StroopColor Word Test (SCWT).Twenty five male (Age 19.52±0.714, BMI 22.73±2 kg/m2) and twenty five female subjects (Age 19.80±0.65, BMI 22.39±1.9) performed SCWT for five minutes. Blood Pressure (SBP p<0.01, DBP p<0.042) & Mean HR (p<0.010) values showed statistically significant difference among the genders. HRV indices like LFms2 (p<0.051), HF nu (p<0.029) and LF/HF ratio (p<0.025, p<0.052) show statistically significant difference among the genders. The response by the cardiovascular system to a simple mental stressor exhibits difference among the genders.

  13. Micro-computed Tomography versus the Cross-sectioning Method to Evaluate Dentin Defects Induced by Different Mechanized Instrumentation Techniques.

    PubMed

    Stringheta, Carolina Pessoa; Pelegrine, Rina Andréa; Kato, Augusto Shoji; Freire, Laila Gonzales; Iglecias, Elaine Faga; Gavini, Giulio; Bueno, Carlos Eduardo da Silveira

    2017-12-01

    The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Culture of chicken embryo in interspecific surrogate egg white.

    PubMed

    Liu, C; Zu, J; Baskar, V; Wernery, U; Chang, I K

    2012-11-01

    The effect of interspecific egg white on the development of chicken embryos was investigated in a surrogate eggshell culture system. Egg yolks were separated from fertile White Leghorn chicken eggs and cultured in different egg whites from turkey (group TK), guineafowl (group GF), and duck (group DK), and chicken (group CK) was used as control. The viability of chicken embryos in groups CK, TK, GF, and DK after 3 d culture in system II was 98.3, 90.2, 96.1, and 91.1%. The whole contents (egg yolk and surrogate egg white) were further transferred into an eggshell from a 1.5 times heavier chicken egg with air space (system III), and incubated for further 16 d, before moving them to a hatcher. No significant difference between the 4 groups was found in their viabilities, which ranged between 72.9 and 81.3%, until 14 d postincubation (P > 0.05). After 21 d, the viability decreased to 60.4, 57.4, 50.0, and 27.7% in groups CK, TK, GF, and DK. The viability in group DK was significantly lower than in the other groups (P < 0.05). Weight loss in system III was approximately 12% in all the 4 groups without significant difference (P > 0.05). Hatchability of the chicken embryo was 60.4, 55.3, 47.9, and 19.1% in groups CK, TK, GF, and DK, respectively, and that in group DK was significantly lower than in the other groups (P < 0.05). There was no difference between the other groups (P > 0.05). These results show that chicken embryos can develop to hatch in duck, guineafowl, and turkey egg whites. However, the hatchability decreases according to the phylogenetic distance. The present study will provide a tool for manipulation of avian embryos and eventual conservation of endangered wild birds.

  15. Can parenting practices predict externalizing behavior problems among children with hearing impairment?

    PubMed

    Pino, María J; Castillo, Rosa A; Raya, Antonio; Herruzo, Javier

    2017-11-09

    To identify possible differences in the level of externalizing behavior problems among children with and without hearing impairment and determine whether any relationship exists between this type of problem and parenting practices. The Behavior Assessment System for Children was used to evaluate externalizing variables in a sample of 118 boys and girls divided into two matched groups: 59 with hearing disorders and 59 normal-hearing controls. Significant between-group differences were found in hyperactivity, behavioral problems, and externalizing problems, but not in aggression. Significant differences were also found in various aspects of parenting styles. A model for predicting externalizing behavior problems was constructed, achieving a predicted explained variance of 50%. Significant differences do exist between adaptation levels in children with and without hearing impairment. Parenting style also plays an important role.

  16. Cost analysis of robotic versus laparoscopic general surgery procedures.

    PubMed

    Higgins, Rana M; Frelich, Matthew J; Bosler, Matthew E; Gould, Jon C

    2017-01-01

    Robotic surgical systems have been used at a rapidly increasing rate in general surgery. Many of these procedures have been performed laparoscopically for years. In a surgical encounter, a significant portion of the total costs is associated with consumable supplies. Our hospital system has invested in a software program that can track the costs of consumable surgical supplies. We sought to determine the differences in cost of consumables with elective laparoscopic and robotic procedures for our health care organization. De-identified procedural cost and equipment utilization data were collected from the Surgical Profitability Compass Procedure Cost Manager System (The Advisory Board Company, Washington, DC) for our health care system for laparoscopic and robotic cholecystectomy, fundoplication, and inguinal hernia between the years 2013 and 2015. Outcomes were length of stay, case duration, and supply cost. Statistical analysis was performed using a t-test for continuous variables, and statistical significance was defined as p < 0.05. The total cost of consumable surgical supplies was significantly greater for all robotic procedures. Length of stay did not differ for fundoplication or cholecystectomy. Length of stay was greater for robotic inguinal hernia repair. Case duration was similar for cholecystectomy (84.3 robotic and 75.5 min laparoscopic, p = 0.08), but significantly longer for robotic fundoplication (197.2 robotic and 162.1 min laparoscopic, p = 0.01) and inguinal hernia repair (124.0 robotic and 84.4 min laparoscopic, p = ≪0.01). We found a significantly increased cost of general surgery procedures for our health care system when cases commonly performed laparoscopically are instead performed robotically. Our analysis is limited by the fact that we only included costs associated with consumable surgical supplies. The initial acquisition cost (over $1 million for robotic surgical system), depreciation, and service contract for the robotic and laparoscopic systems were not included in this analysis.

  17. Laying performance and egg quality of blue-shelled layers as affected by different housing systems.

    PubMed

    Wang, X L; Zheng, J X; Ning, Z H; Qu, L J; Xu, G Y; Yang, N

    2009-07-01

    Blue-shelled eggs are gaining popularity as the consumption demand diversifies in some countries. This study was carried out to investigate the laying performance and egg quality of the blue-shelled egg layers as well as the effects of different housing systems on egg production and quality traits. One thousand pullets from Dongxiang blue-shelled layers were divided into 2 even groups and kept in different housing systems (outdoor vs. cage). Daily laying performance was recorded from 20 to 60 wk of age. External and internal egg quality traits were examined at 26, 34, 42, and 50 wk. Yolk cholesterol concentration and whole egg cholesterol content were measured at 40 wk of age. Average laying rate from 20 to 60 wk for the cage (54.7%) was significantly higher than that of outdoor layers (39.3%). Among all of the egg quality traits, only eggshell color was affected by housing system. Interaction between housing system and layer age was found in egg weight, eggshell color, eggshell ratio, yolk color, and yolk weight. Meanwhile, cholesterol concentration in yolk was 8.64 +/- 0.40 mg/g in the outdoor eggs, which was significantly lower than that of eggs from the cage birds (10.32 +/- 0.48 mg/g; P < 0.05). Whole egg cholesterol content in the outdoor eggs (125.23 +/- 6.32 mg/egg) was also significantly lower than that of eggs from the caged layers (158.01 +/- 8.62 mg/egg). The results demonstrated that blue-shelled layers have lower productivity in the outdoor system than in the cage system. Blue-shelled layers have lower egg weight, larger yolk proportion, and lower cholesterol content compared with commercial layers. In a proper marketing system, lower productivity could be balanced by a higher price for the better quality of blue-shelled eggs.

  18. Job Involvement and Organizational Commitment of Employees of Prehospital Emergency Medical System.

    PubMed

    Rahati, Alireza; Sotudeh-Arani, Hossein; Adib-Hajbaghery, Mohsen; Rostami, Majid

    2015-12-01

    Several studies are available on organizational commitment of employees in different organizations. However, the organizational commitment and job involvement of the employees in the prehospital emergency medical system (PEMS) of Iran have largely been ignored. This study aimed to investigate the organizational commitment and job involvement of the employees of PEMS and the relationship between these two issues. This cross-sectional study was conducted on 160 employees of Kashan PEMS who were selected through a census method in 2014. A 3-part instrument was used in this study, including a demographic questionnaire, the Allen and Miller's organizational commitment inventory, and the Lodahl and Kejner's job involvement inventory. We used descriptive statistics, Spearman correlation coefficient, Kruskal-Wallis, Friedman, analysis of variance, and Tukey post hoc tests to analyze the data. The mean job involvement and organizational commitment scores were 61.78 ± 10.69 and 73.89 ± 13.58, respectively. The mean scores of job involvement and organizational commitment were significantly different in subjects with different work experiences (P = 0.043 and P = 0.012, respectively). However, no significant differences were observed between the mean scores of organizational commitment and job involvement in subjects with different fields of study, different levels of interest in the profession, and various educational levels. A direct significant correlation was found between the total scores of organizational commitment and job involvement of workers in Kashan PEMS (r = 0.910, P < 0.001). This study showed that the employees in the Kashan PEMS obtained half of the score of organizational commitment and about two-thirds of the job involvement score. Therefore, the higher level managers of the emergency medical system are advised to implement some strategies to increase the employees' job involvement and organizational commitment.

  19. Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT.

    PubMed

    Rödig, T; Reicherts, P; Konietschke, F; Dullin, C; Hahn, W; Hülsmann, M

    2014-10-01

    To compare the efficacy of reciprocating and rotary NiTi-instruments in removing filling material from curved root canals using micro-computed tomography. Sixty curved root canals were prepared and filled with gutta-percha and sealer. After determination of root canal curvatures and radii in two directions as well as volumes of filling material, the teeth were assigned to three comparable groups (n = 20). Retreatment was performed using Reciproc, ProTaper Universal Retreatment or Hedström files. Percentages of residual filling material and dentine removal were assessed using micro-CT imaging. Working time and procedural errors were recorded. Statistical analysis was performed by variance procedures. No significant differences amongst the three retreatment techniques concerning residual filling material were detected (P > 0.05). Hedström files removed significantly more dentine than ProTaper Universal Retreatment (P < 0.05), but the difference concerning dentine removal between both NiTi systems was not significant (P > 0.05). Reciproc and ProTaper Universal Retreatment were significantly faster than Hedström files (P = 0.0001). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected for Hedström files. Three perforations were recorded for ProTaper Universal Retreatment, and in both NiTi groups, one instrument fracture occured. Remnants of filling material were observed in all samples with no significant differences between the three techniques. Hedström files removed significantly more dentine than ProTaper Universal Retreatment, but no significant differences between both NiTi systems were detected. Procedural errors were observed with ProTaper Universal Retreatment and Reciproc. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  20. Output variability across animals and levels in a motor system

    PubMed Central

    Norris, Brian J; Günay, Cengiz; Kueh, Daniel

    2018-01-01

    Rhythmic behaviors vary across individuals. We investigated the sources of this output variability across a motor system, from the central pattern generator (CPG) to the motor plant. In the bilaterally symmetric leech heartbeat system, the CPG orchestrates two coordinations in the bilateral hearts with different intersegmental phase relations (Δϕ) and periodic side-to-side switches. Population variability is large. We show that the system is precise within a coordination, that differences in repetitions of a coordination contribute little to population output variability, but that differences between bilaterally homologous cells may contribute to some of this variability. Nevertheless, much output variability is likely associated with genetic and life history differences among individuals. Variability of Δϕ were coordination-specific: similar at all levels in one, but significantly lower for the motor pattern than the CPG pattern in the other. Mechanisms that transform CPG output to motor neurons may limit output variability in the motor pattern. PMID:29345614

  1. Choosing Your Poison: Optimizing Simulator Visual System Selection as a Function of Operational Tasks

    NASA Technical Reports Server (NTRS)

    Sweet, Barbara T.; Kaiser, Mary K.

    2013-01-01

    Although current technology simulator visual systems can achieve extremely realistic levels they do not completely replicate the experience of a pilot sitting in the cockpit, looking at the outside world. Some differences in experience are due to visual artifacts, or perceptual features that would not be present in a naturally viewed scene. Others are due to features that are missing from the simulated scene. In this paper, these differences will be defined and discussed. The significance of these differences will be examined as a function of several particular operational tasks. A framework to facilitate the choice of visual system characteristics based on operational task requirements will be proposed.

  2. Design and implementation of streaming media server cluster based on FFMpeg.

    PubMed

    Zhao, Hong; Zhou, Chun-long; Jin, Bao-zhao

    2015-01-01

    Poor performance and network congestion are commonly observed in the streaming media single server system. This paper proposes a scheme to construct a streaming media server cluster system based on FFMpeg. In this scheme, different users are distributed to different servers according to their locations and the balance among servers is maintained by the dynamic load-balancing algorithm based on active feedback. Furthermore, a service redirection algorithm is proposed to improve the transmission efficiency of streaming media data. The experiment results show that the server cluster system has significantly alleviated the network congestion and improved the performance in comparison with the single server system.

  3. Design and Implementation of Streaming Media Server Cluster Based on FFMpeg

    PubMed Central

    Zhao, Hong; Zhou, Chun-long; Jin, Bao-zhao

    2015-01-01

    Poor performance and network congestion are commonly observed in the streaming media single server system. This paper proposes a scheme to construct a streaming media server cluster system based on FFMpeg. In this scheme, different users are distributed to different servers according to their locations and the balance among servers is maintained by the dynamic load-balancing algorithm based on active feedback. Furthermore, a service redirection algorithm is proposed to improve the transmission efficiency of streaming media data. The experiment results show that the server cluster system has significantly alleviated the network congestion and improved the performance in comparison with the single server system. PMID:25734187

  4. Majorana modes in solid state systems and its dynamics

    NASA Astrophysics Data System (ADS)

    Zhang, Qi; Wu, Biao

    2018-04-01

    We review the properties of Majorana fermions in particle physics and point out that Majorana modes in solid state systems are significantly different. The key reason is the concept of anti-particle in solid state systems is different from its counterpart in particle physics. We define Majorana modes as the eigenstates of Majorana operators and find that they can exist both at edges and in the bulk. According to our definition, only one single Majorana mode can exist in a system no matter at edges or in the bulk. Kitaev's spinless p-wave superconductor is used to illustrate our results and the dynamical behavior of the Majorana modes.

  5. [In-situ measurement of background atmospheric HCFC-142b using GC-MS and GC-ECD method].

    PubMed

    Guo, Li-feng; Yao, Bo; Zhou, Ling-xi; Li, Pei-chang; Xu, Lin

    2013-05-01

    Custom-made GC-MS and GC-ECD in-situ measurement systems were established at the Shangdianzi GAW Regional station. From May 2010 to May 2011, the precisions for GC-MS and GC-ECD systems were 0.23% and 0.88%, respectively, and the HCFC-142b mole fraction during the observation period ranged from 21 x 10(-12) to 355 x 10(-12). The result of the independent-sample T test was P > 0.05, and there was no significant difference in HCFC-142b mole fraction measured by the two systems. The small difference of HCFC-142b mole fraction measured by GC-MS and GC-ECD might be associated with the different sampling time and precision of the two systems. A statistical filter of "robust local regression" was applied to separate HCFC-142b background and pollution data. The mean difference, median difference, 25 and 75 percent difference of background data measured by GC-MS and GC-ECD were all within the precisions. The pollution events captured by the two systems showed similar characters. Results from both systems showed a higher HCFC-142b level in summer and autumn than in winter. The pollution mole fraction of the two systems showed similar seasonal changes.

  6. Long-term effect of rice-based farming systems on soil health.

    PubMed

    Bihari, Priyanka; Nayak, A K; Gautam, Priyanka; Lal, B; Shahid, M; Raja, R; Tripathi, R; Bhattacharyya, P; Panda, B B; Mohanty, S; Rao, K S

    2015-05-01

    Integrated rice-fish culture, an age-old farming system, is a technology which could produce rice and fish sustainably at a time by optimizing scarce resource use through complementary use of land and water. An understanding of microbial processes is important for the management of farming systems as soil microbes are the living part of soil organic matter and play critical roles in soil C and N cycling and ecosystem functioning of farming system. Rice-based integrated farming system model for small and marginal farmers was established in 2001 at Central Rice Research Institute, Cuttack, Odisha. The different enterprises of farming system were rice-fish, fish-fingerlings, fruits, vegetables, rice-fish refuge, and agroforestry. This study was conducted with the objective to assess the soil physicochemical properties, microbial population, carbon and nitrogen fractions, soil enzymatic activity, and productivity of different enterprises. The effect of enterprises induced significant changes in the chemical composition and organic matter which in turn influenced the activities of enzymes (urease, acid, and alkaline phosphatase) involved in the C, N, and P cycles. The different enterprises of long-term rice-based farming system caused significant variations in nutrient content of soil, which was higher in rice-fish refuge followed by rice-fish enterprise. Highest microbial populations and enzymatic properties were recorded in rice-fish refuge system because of waterlogging and reduced condition prolonged in this system leading to less decomposition of organic matter. The maximum alkaline phosphatase, urease, and FDA were observed in rice-fish enterprise. However, highest acid phosphatase and dehydrogenase activity were obtained in vegetable enterprise and fish-fingerlings enterprise, respectively.

  7. Multiple access capacity trade-offs for a Ka-band personal access satellite system

    NASA Technical Reports Server (NTRS)

    Dessouky, Khaled; Motamedi, Masoud

    1990-01-01

    System capability is critical to the economic viability of a personal satellite communication system. Ka band has significant potential to support a high capacity multiple access system because of the availability of bandwidth. System design tradeoffs are performed and multiple access schemes are compared with the design goal of achieving the highest capacity and efficiency. Conclusions regarding the efficiency of the different schemes and the achievable capacities are given.

  8. Shaping ability of the conventional nickel-titanium and reciprocating nickel-titanium file systems: a comparative study using micro-computed tomography.

    PubMed

    Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo

    2014-08-01

    This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P < .05). In the scanning electron microscopic analysis, file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Antioxidant status and alpha1-antiproteinase activity in subarachnoid hemorrhage patients.

    PubMed

    Marzatico, F; Gaetani, P; Tartara, F; Bertorelli, L; Feletti, F; Adinolfi, D; Tancioni, F; Rodriguez y Baena, R

    1998-01-01

    The antiproteasic activity of alpha1-antitrypsin (alpha1-AT) is reduced in cases of subarachnoid hemorrhage from ruptured intracranial aneurysm and particularly in patients currently smoking; alpha1-AT is very sensitive to oxidant agents. About 50% of physiological anti-oxidant systemic capacity is represented by Vitamin A, E and C. Plasmatic amounts of alpha1-AT, alpha1-AT Collagenase Inhibitory Capacity (CIC) and levels of vitamin A, vitamin E and vitamin C were analyzed in 39 patients, 26 women and 13 men, operated for intracranial aneurysm; 11 patients with unruptured intracranial aneurysm were considered as controls while 28 patients were included within 12 hours from subarachnoid hemorrhage (SAH). Plasmatic levels of vitamin A and vitamin E were significantly lower (p=0.038 and p=0.0158) in patients suffering SAH than in controls, while no statistically significant differences were found in mean plasmatic vitamin C levels. Level of alpha1-AT was not statistically different in controls and in patients with SAH; however, the activity of alpha1-AT, evaluated as CIC, is significantly reduced in patients with SAH (p=0.019). We have observed that systemic plasmatic levels of vitamins did not significantly differ in relation to smoking habit. Vitamin A and E represent an important defensive system against free radicals reactions. Particularly, vitamin E acts as an antioxidant by scavenging free-radicals. A reduced anti-oxidant status might be related to the higher sensibility of alpha1-AT to oxidative reactions and the activity of alpha1-AT is dependent on the antioxidant capacity of liposoluble vitamins. We can speculate that an acute systemic oxidative stress condition might influence the rupture of intracranial aneurysms.

  10. Understanding Genetic Breast Cancer Risk: Processing Loci of the BRCA Gist Intelligent Tutoring System

    PubMed Central

    Wolfe, Christopher R.; Reyna, Valerie F.; Widmer, Colin L.; Cedillos-Whynott, Elizabeth M.; Brust-Renck, Priscila G; Weil, Audrey M.; Hu, Xiangen

    2016-01-01

    The BRCA Gist Intelligent Tutoring System helps women understand and make decisions about genetic testing for breast cancer risk. BRCA Gist is guided by Fuzzy-Trace Theory, (FTT) and built using AutoTutor Lite. It responds differently to participants depending on what they say. Seven tutorial dialogues requiring explanation and argumentation are guided by three FTT concepts: forming gist explanations in one’s own words, emphasizing decision-relevant information, and deliberating the consequences of decision alternatives. Participants were randomly assigned to BRCA Gist, a control, or impoverished BRCA Gist conditions removing gist explanation dialogues, argumentation dialogues, or FTT images. All BRCA Gist conditions performed significantly better than controls on knowledge, comprehension, and risk assessment. Significant differences in knowledge, comprehension, and fine-grained dialogue analyses demonstrate the efficacy of gist explanation dialogues. FTT images significantly increased knowledge. Providing more elements in arguments against testing correlated with increased knowledge and comprehension. PMID:28008216

  11. Understanding Genetic Breast Cancer Risk: Processing Loci of the BRCA Gist Intelligent Tutoring System.

    PubMed

    Wolfe, Christopher R; Reyna, Valerie F; Widmer, Colin L; Cedillos-Whynott, Elizabeth M; Brust-Renck, Priscila G; Weil, Audrey M; Hu, Xiangen

    2016-07-01

    The BRCA Gist Intelligent Tutoring System helps women understand and make decisions about genetic testing for breast cancer risk. BRCA Gist is guided by Fuzzy-Trace Theory, (FTT) and built using AutoTutor Lite. It responds differently to participants depending on what they say. Seven tutorial dialogues requiring explanation and argumentation are guided by three FTT concepts: forming gist explanations in one's own words, emphasizing decision-relevant information, and deliberating the consequences of decision alternatives. Participants were randomly assigned to BRCA Gist , a control, or impoverished BRCA Gist conditions removing gist explanation dialogues, argumentation dialogues, or FTT images. All BRCA Gist conditions performed significantly better than controls on knowledge, comprehension, and risk assessment. Significant differences in knowledge, comprehension, and fine-grained dialogue analyses demonstrate the efficacy of gist explanation dialogues. FTT images significantly increased knowledge. Providing more elements in arguments against testing correlated with increased knowledge and comprehension.

  12. Initial tension loss in cerclage cables.

    PubMed

    Ménard, Jérémie; Émard, Maxime; Canet, Fanny; Brailovski, Vladimir; Petit, Yvan; Laflamme, George Y

    2013-10-01

    Cerclage cables, frequently used in the management of fractures and osteotomies, are associated with a high failure rate and significant loosening during surgery. This study compared the capacity to maintain tension of different types of orthopaedic cable systems. Multifilament Cobalt-Chrome (CoCr) cables with four different crimp/clamp devices (DePuy, Stryker, Zimmer and Smith&Nephew) and one non-metallic Nylon (Ny) cable from Kinamed were instrumented with a load cell to measure tension during insertion. Significant tension loss was observed with crimping for all cables (P<0.05). Removing the tensioner led to an additional unexpected tension loss (CoCr-DePuy: 18%, CoCr-Stryker: 29%, CoCr-Smith&Nephew: 33%, Ny: 46%, and CoCr-Zimmer: 52%). The simple CoCr (DePuy) cable system outperformed the more sophisticated locking devices due to its significantly better ability to prevent tension loss. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. The use of computer-assisted image analysis in the evaluation of the effect of management systems on changes in the color, chemical composition and texture of m. longissimus dorsi in pigs.

    PubMed

    Zapotoczny, Piotr; Kozera, Wojciech; Karpiesiuk, Krzysztof; Pawłowski, Rodian

    2014-08-01

    The effect of management systems on selected physical properties and chemical composition of m. longissimus dorsi was studied in pigs. Muscle texture parameters were determined by computer-assisted image analysis, and the color of muscle samples was evaluated using a spectrophotometer. Highly significant correlations were observed between chemical composition and selected texture variables in the analyzed images. Chemical composition was not correlated with color or spectral distribution. Subject to the applied classification methods and groups of variables included in the classification model, the experimental groups were identified correctly in 35-95%. No significant differences in the chemical composition of m. longissimus dorsi were observed between experimental groups. Significant differences were noted in color lightness (L*) and redness (a*). Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. "Nonspecific" cholinesterase and acetylcholinesterase in rat tissues: molecular forms, structural and catalytic properties, and significance of the two enzyme systems.

    PubMed Central

    Vigny, M; Gisiger, V; Massoulié, J

    1978-01-01

    "Nonspecific" cholinesterase (acylcholine acylhydrolase; EC 3.1.1.8) from various rat tissues has been found to exist in several stable molecular forms that appear as exact counterparts of molecular forms of acetylcholinesterase (acetylcholine hydrolase; EC 3.1.1.7). The sedimentation pattern of cholinesterase was similar to that of acetylcholinesterase with a small but significant shift between the sedimentation coefficients of the corresponding forms. Extraction yields in different media also demonstrated a close parallelism between the two enzyme systems. Other properties, such as thermal stability and catalytic characteristics, indicated both differences and similarities. In spite of the structural resemblance implied by their physicochemical properties, cholinesterase did not crossreact with antibodies against acetylcholinesterase. The nature of the relationships revealed by these studies and their bearing on the physiological significance of cholinesterases are discussed. PMID:78492

  15. Pain perception and cardiovascular system response among athletes playing contact sports.

    PubMed

    Leźnicka, Katarzyna; Pawlak, Matthias; Białecka, Monika; Safranow, Krzysztof; Cięszczyk, Paweł

    2017-01-01

    The aim of this study was to determine whether the contact sports change the perception of pain as assessed by the cold pressor test (CPT), and if the test induces the same reaction of the cardiovascular system in contact athletes and non-athletes. The study involved 321 healthy men; 140 contact athletes and 181 students of the University of Szczecin (control). Pain threshold and pain tolerance were evaluated using CPT. Cardiovascular measurements were made during CPT. The contact athletes showed a much higher tolerance to pain than the control group (median time 120 vs. 94 s, respectively, p = 0.0002). The thresholds of pain in both groups did not differ significantly between the groups. Systolic blood pressure measured before and during the test in all three measurements was statistically significantly higher in athletes compared with the control group. Heart rate and diastolic blood pressure did not differ significantly between the studied groups.

  16. Simulator evaluation of the effects of reduced spoiler and thrust authority on a decoupled longitudinal control system during landings in wind shear

    NASA Technical Reports Server (NTRS)

    Miller, G. K., Jr.

    1981-01-01

    The effect of reduced control authority, both in symmetric spoiler travel and thrust level, on the effectiveness of a decoupled longitudinal control system was examined during the approach and landing of the NASA terminal configured vehicle (TCV) aft flight deck simulator in the presence of wind shear. The evaluation was conducted in a fixed-base simulator that represented the TCV aft cockpit. There were no statistically significant effects of reduced spoiler and thrust authority on pilot performance during approach and landing. Increased wind severity degraded approach and landing performance by an amount that was often significant. However, every attempted landing was completed safely regardless of the wind severity. There were statistically significant differences in performance between subjects, but the differences were generally restricted to the control wheel and control-column activity during the approach.

  17. Lymphatic microangiopathy of the skin in systemic sclerosis.

    PubMed

    Leu, A J; Gretener, S B; Enderlin, S; Brühlmann, P; Michel, B A; Kowal-Bielecka, O; Hoffmann, U; Franzeck, U K

    1999-03-01

    The cutaneous capillary lymphatic system in patients with systemic sclerosis was investigated using fluorescence microlymphography. The distal upper limbs of 16 healthy controls (mean age 62.3+/-13.1 yr) and 16 patients with systemic sclerosis (mean age 58.9+/-13.6 yr) were examined and the following parameters were evaluated: (a) single lymphatic capillaries; (b) lymphatic capillary network and cutaneous backflow; (c) extension of the stained lymphatics; (d) diameter of single lymphatic capillaries. At the finger level, lymphatic capillaries were lacking in five patients, while they were present in all controls (P < 0.05). Extension of the stained lymphatics was increased in 11 patients (8.1+/-6.0 mm) compared to the 16 healthy controls (2.0+/-1.2 mm) (P < 0.0001). Cutaneous backflow was observed in three patients (P < 0.05). At the hand level, lymphatic network extension was significantly different between patients (3.8+/-2.4 mm) and controls (1.2+/-0.8 mm) (P < 0.01); however, no significant differences were found at the forearm level. Lesional skin in patients with systemic sclerosis exhibits evidence of lymphatic microangiopathy.

  18. Subjective evaluation of two stereoscopic imaging systems exploiting visual attention to improve 3D quality of experience

    NASA Astrophysics Data System (ADS)

    Hanhart, Philippe; Ebrahimi, Touradj

    2014-03-01

    Crosstalk and vergence-accommodation rivalry negatively impact the quality of experience (QoE) provided by stereoscopic displays. However, exploiting visual attention and adapting the 3D rendering process on the fly can reduce these drawbacks. In this paper, we propose and evaluate two different approaches that exploit visual attention to improve 3D QoE on stereoscopic displays: an offline system, which uses a saliency map to predict gaze position, and an online system, which uses a remote eye tracking system to measure real time gaze positions. The gaze points were used in conjunction with the disparity map to extract the disparity of the object-of-interest. Horizontal image translation was performed to bring the fixated object on the screen plane. The user preference between standard 3D mode and the two proposed systems was evaluated through a subjective evaluation. Results show that exploiting visual attention significantly improves image quality and visual comfort, with a slight advantage for real time gaze determination. Depth quality is also improved, but the difference is not significant.

  19. Liquid Rocket Booster (LRB) for the Space Transportation System (STS) systems study. Appendix B: Liquid rocket booster acoustic and thermal environments

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The ascent thermal environment and propulsion acoustic sources for the Martin-Marietta Corporation designed Liquid Rocket Boosters (LRB) to be used with the Space Shuttle Orbiter and External Tank are described. Two designs were proposed: one using a pump-fed propulsion system and the other using a pressure-fed propulsion system. Both designs use LOX/RP-1 propellants, but differences in performance of the two propulsion systems produce significant differences in the proposed stage geometries, exhaust plumes, and resulting environments. The general characteristics of the two designs which are significant for environmental predictions are described. The methods of analysis and predictions for environments in acoustics, aerodynamic heating, and base heating (from exhaust plume effects) are also described. The acoustic section will compare the proposed exhaust plumes with the current SRB from the standpoint of acoustics and ignition overpressure. The sections on thermal environments will provide details of the LRB heating rates and indications of possible changes in the Orbiter and ET environments as a result of the change from SRBs to LRBs.

  20. Differential effects of MK-801 on cerebrocortical neuronal injury in C57BL/6J, NSA, and ICR mice.

    PubMed

    Brosnan-Watters, G; Ogimi, T; Ford, D; Tatekawa, L; Gilliam, D; Bilsky, E J; Nash, D

    2000-08-01

    1. Antagonists of the N-methyl-D-aspartate (NMDA) glutamate (Glu) receptor, including [(+)-5-methyl-10,11-dihydro-5H-dibenzo[a,d]cyclohepten-5,10-imine maleate], dizocilpine maleate (MK-801), injure pyramidal neurons in the posterior cingulate/retrosplenial (PC/RS) cortex when administered systemically to adult rats and mice. 2. These results have, to our knowledge, only been reported previously in Harlan Sprague Dawley albino rats and International Cancer Research (ICR) mice, an outbred albino strain. 3. Male Non-Swiss Albino (NSA) mice, an albino outbred strain, and male C57BL/6J (B6) mice, a pigmented inbred strain, were injected systemically with 1 mg/kg of MK-801 in the first experiment. This dose of MK-801 reliably produces cytoplasmic vacuoles in neurons in layers III and IV of the PC/RS cortex in 100% of ICR mice treated 4. There was a significant difference in the number of vacuolated neurons in B6 and NSA mice, as assessed by ANOVA. The NSA were not significantly different than previously examined ICR mice, but the B6 had fewer vacuolated neurons than either of the two outbred strains. 5. In the second experiment, male NSA, ICR, and B6 mice were injected systemically with a high dose, 10 mg/kg, of MK-801. This dose has been demonstrated to result in necrosis in the same population of neurons injured by lower doses of MK-801. 6. An ANOVA indicated that there was a significant difference among the three strains of mice, and a Fisher's protected t revealed that the B6 mice were significantly different from both the NSA and ICR, but that, with our test, those two strains were indistinguishable. 7. Male ICR, NSA, and B6 mice were tested in the holeboard food search task 5 hours after 1 mg/kg of MK-801. There were significant differences between the strains in performance both pre and posttreatment. The effect of the drug was not statistically significant. 8. These results suggest that there may be a genetically mediated difference in the reaction to NMDA receptor antagonists, a finding which may be important given the NMDA receptor hypofunction hypothesis for the etiology of schizophrenic symptoms.

  1. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    PubMed

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems

    PubMed Central

    H, Farhadpour; F, Sharafeddin; Sc, Akbarian; B, Azarian

    2016-01-01

    Statement of Problem: Hemostatic agents may affect the micro-leakage of different adhesive systems. Also, chlorhexidine has shown positive effects on micro-leakage. However, their interaction effect has not been reported yet. Objectives: To evaluate the effect of contamination with a hemostatic agent on micro-leakage of total- and self-etching adhesive systems and the effect of chlorhexidine application after the removal of the hemostatic agent. Materials and Methods: Standardized Class V cavity was prepared on each of the sixty caries free premolars at the cemento-enamel junction, with the occlusal margin located in enamel and the gingival margin in dentin. Then, the specimens were randomly divided into 6 groups (n = 10) according to hemostatic agent (H) contamination, chlorhexidine (CHX) application, and the type of adhesive systems (Adper Single Bond and Clearfil SE Bond) used. After filling the cavities with resin composite, the root apices were sealed with utility wax. Furthermore, all the surfaces, except for the restorations and 1mm from the margins, were covered with two layers of nail varnish. The teeth were immersed in a 0.5% basic fuschin dye for 24 hours, rinsed, blot-dried and sectioned longitudinally through the center of the restorations bucco- lingualy. The sections were examined using a stereomicroscope and the extension of dye penetration was analyzed according to a non-parametric scale from 0 to 3. Statistical analysis was performed using Kruskal-Wallis test and Mann-Whitney U-test. Results: While ASB group showed no micro-leakage in enamel, none of the groups showed complete elimination of micro-leakage from the dentin. Regarding micro-leakage at enamel, and dentin margins, there was no significant difference between groups 1 and 2, 1 and 3, and 2 and 3 (p > 0.05). A significantly lower micro-leakage at the enamel and dentin margins was observed in group 3, compared to group 6. No significant difference was observed between groups 4 and 5 in enamel (p = 0.35) and dentin (p = 0.34). Group 6 showed significantly higher micro-leakage, compared to group 4 and 5 (p < 0.05). Conclusions: Hemostatic agent contamination had no significant effect on micro-leakage of total- and self-etching adhesive systems. Application of chlorhexidine after the removal of hemostatic agent increased micro-leakage in self-etching adhesives but did not affect when total-etching was used. PMID:28959756

  3. The effects of system-justifying motives on endorsement of essentialist explanations for gender differences.

    PubMed

    Brescoll, Victoria L; Uhlmann, Eric Luis; Newman, George E

    2013-12-01

    People have a fundamental motive to view their social system as just, fair, and good and will engage in a number of strategies to rationalize the status quo (Jost & Banaji, 1994). We propose that one way in which individuals may "justify the system" is through endorsement of essentialist explanations, which attribute group differences to deep, essential causes. We suggest that system-justifying motives lead to greater endorsement of essentialist explanations because those explanations portray group differences as immutable. Study 1 employed an established system threat manipulation. We found that activating system-justifying motives increases both male and female participants' endorsement of essentialist explanations for gender differences and that this effect is mediated by beliefs in immutability. In Study 2, we used a goal contagion manipulation and found that both male and female participants primed with a system-justifying goal are significantly more likely to agree with essentialist explanations for gender differences. Study 3 demonstrated that providing an opportunity to explicitly reject a system threat (an alternative means of satisfying the goal to defend the system) attenuates system threat effects on endorsement of essentialist explanations, further suggesting that this process is motivated. Finally, Studies 4a and 4b dissociated the type of cause (biological vs. social) from whether group differences are portrayed as mutable versus immutable and found that system threat increases endorsement of immutable explanations, independent of the type of cause. PsycINFO Database Record (c) 2013 APA, all rights reserved

  4. Effect of the Stroop test performed in supine position on the heart rate variability in both genders.

    PubMed

    Vazan, Rastislav; Filcikova, Diana; Mravec, Boris

    2017-12-01

    The effect of Stroop test (ST)-induced stress on autonomic nervous system activity is often examined via measurement of heart rate variability (HRV). However, HRV may be significantly affected by interfering factors, including vocalization and inappropriate body position. Surprisingly, published studies ignore these issues, so the aim of our study was to test the innovative procedure for correct HRV measurement in individuals exposed to ST. Moreover, we examined possible gender differences in HRV and heart rate (HR) during ST. Healthy participants (21 men, 34 women) were placed in a supine position (no orthostatic activation) and then exposed to a 5 min relaxation period and a 5 min period of computerized ST (no vocalization). We found significant differences in HR and HRV parameters in both genders during ST when compared to relaxation (baseline) values. On the other hand, there were no significant differences in HR and HRV between males and females (except for a higher baseline HR in women). Also, reactivity to ST stress (difference between baseline and ST value) showed no gender differences. In conclusion, when performed in a supine position and without vocalization, the ST induces significant stress-related changes of HR and HRV in both genders, with no gender differences in the magnitude of reaction to ST stress. This experimental procedure can be used for correct examination of mental stress-related changes in the autonomic nervous system, and is particularly useful for examining mixed-gender experimental groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Seasonal differences in relationships between nitrate concentration and denitrification rates in ditch sediments vegetated with rice cutgrass (Leersia oryzoides)

    USDA-ARS?s Scientific Manuscript database

    Increased application of nitrogen (N) fertilizers in agricultural systems contributes to significant environmental impacts, including eutrophication of fresh and coastal waters. Rice cutgrass (Leersia oryzoides) can significantly enhance denitrification potential in agricultural ditch sediments and ...

  6. The relation between receptive grammar and procedural, declarative, and working memory in specific language impairment.

    PubMed

    Conti-Ramsden, Gina; Ullman, Michael T; Lum, Jarrad A G

    2015-01-01

    What memory systems underlie grammar in children, and do these differ between typically developing (TD) children and children with specific language impairment (SLI)? Whilst there is substantial evidence linking certain memory deficits to the language problems in children with SLI, few studies have investigated multiple memory systems simultaneously, examining not only possible memory deficits but also memory abilities that may play a compensatory role. This study examined the extent to which procedural, declarative, and working memory abilities predict receptive grammar in 45 primary school aged children with SLI (30 males, 15 females) and 46 TD children (30 males, 16 females), both on average 9;10 years of age. Regression analyses probed measures of all three memory systems simultaneously as potential predictors of receptive grammar. The model was significant, explaining 51.6% of the variance. There was a significant main effect of learning in procedural memory and a significant group × procedural learning interaction. Further investigation of the interaction revealed that procedural learning predicted grammar in TD but not in children with SLI. Indeed, procedural learning was the only predictor of grammar in TD. In contrast, only learning in declarative memory significantly predicted grammar in SLI. Thus, different memory systems are associated with receptive grammar abilities in children with SLI and their TD peers. This study is, to our knowledge, the first to demonstrate a significant group by memory system interaction in predicting grammar in children with SLI and their TD peers. In line with Ullman's Declarative/Procedural model of language and procedural deficit hypothesis of SLI, variability in understanding sentences of varying grammatical complexity appears to be associated with variability in procedural memory abilities in TD children, but with declarative memory, as an apparent compensatory mechanism, in children with SLI.

  7. Effects of Housing Systems on Behaviour, Performance and Welfare of Fast-growing Broilers

    PubMed Central

    Zhao, Zi-guang; Li, Jian-hong; Li, Xiang; Bao, Jun

    2014-01-01

    This experiment aimed to evaluate the effects of different housing systems on behavioral activities, welfare and meat quality of fast-growing broilers. Two hundred broilers were allocated into two housing systems: indoor housing vs indoor with outdoor access. Their general behavior (feeding, drinking, fighting, standing, lying, walking, investigating, dust-bathing and preening) was observed, and tonic immobility, fluctuating asymmetry of legs and wings were measured, and meat quality was analyzed. The results showed that the indoor-housed broilers with outdoor access had significant higher standing, walking, investigating, dust-bathing and preening than those indoor only. However, farming system was not found to significantly affect their feeding, drinking and fighting activities (p>0.05). The value of FA of tibia length of the broilers with outdoor access was significantly lower than that of the indoor-housed birds (1.57±1.30 vs 2.76±1.40, p<0.05), while no difference was found for the value of FA in tibia diameter and wing length (p>0.05). TI of the broilers with outdoor access was 165.5 that was significantly higher than that (147.2) of the indoor birds (p<0.05). However, death rate in the outdoor run groups was significantly higher than that of the indoor ones (2.0±0.81 vs 4.0±0.82, p<0.05). Meat quality was not affected by the two farming systems. It can be concluded that the results of this study may suggest that the indoor housing with outdoor access provides enriched environment for broilers and facilitates the expression of natural behaviors of the broilers but resulted in poorer performance and higher death rate. PMID:25049936

  8. Analysis of Resin-Dentin Interface Morphology and Bond Strength Evaluation of Core Materials for One Stage Post-Endodontic Restorations

    PubMed Central

    Bitter, Kerstin; Gläser, Christin; Neumann, Konrad; Blunck, Uwe; Frankenberger, Roland

    2014-01-01

    Purpose Restoration of endodontically treated teeth using fiber posts in a one-stage procedure gains more popularity and aims to create a secondary monoblock. Data of detailed analyses of so called “post-and-core-systems” with respect to morphological characteristics of the resin-dentin interface in combination with bond strength measurements of fiber posts luted with these materials are scarce. The present study aimed to analyze four different post-and-core-systems with two different adhesive approaches (self-etch and etch-and-rinse). Materials and Methods Human anterior teeth (n = 80) were endodontically treated and post space preparations and post placement were performed using the following systems: Rebilda Post/Rebilda DC/Futurabond DC (Voco) (RB), Luxapost/Luxacore Z/Luxabond Prebond and Luxabond A+B (DMG) (LC), X Post/Core X Flow/XP Bond and Self Cure Activator (Dentsply DeTrey) (CX), FRC Postec/MultiCore Flow/AdheSE DC (Ivoclar Vivadent) (MC). Adhesive systems and core materials of 10 specimens per group were labeled using fluorescent dyes and resin-dentin interfaces were analyzed using Confocal Laser Scanning Microscopy (CLSM). Bond strengths were evaluated using a push-out test. Data were analyzed using repeated measurement ANOVA and following post-hoc test. Results CLSM analyses revealed significant differences between groups with respect to the factors hybrid layer thickness (p<0.0005) and number of resin tags (p = 0.02; ANOVA). Bond strength was significantly affected by core material (p = 0.001), location inside the root canal (p<0.0005) and incorporation of fluorescent dyes (p = 0.036; ANOVA). CX [7.7 (4.4) MPa] demonstrated significantly lower bond strength compared to LC [14.2 (8.7) MPa] and RB [13.3 (3.7) MPa] (p<0.05; Tukey HSD) but did not differ significantly from MC [11.5 (3.5) MPa]. Conclusion It can be concluded that bond strengths inside the root canal were not affected by the adhesive approach of the post-and-core-system. All systems demonstrated homogenous hybrid layer formation and penetration into the dentinal tubules in spite of the complicating conditions for adhesion inside the root canal. PMID:24586248

  9. Burnout among workers in a pediatric health care system.

    PubMed

    Jacobs, Linda M; Nawaz, Muhammad K; Hood, Joyce L; Bae, Sejong

    2012-08-01

    Burnout among health care workers is recognized as an organizational risk contributing to absenteeism, presenteeism, excessive turnover, or illness, and may also manifest as decreased patient satisfaction. Pediatric health care may add stressors including worried parents of ill or dying children, child custody issues, child abuse, and workplace violence. The purpose of this study was to measure burnout among workers in a regional pediatric health care system and report whether burnout in a pediatric health care system is different from previously published data on human service workers. The Maslach Burnout Inventory-Human Services Survey (MBI-HSS) and the Copenhagen Burnout Inventory (CBI) were used to measure burnout. Pediatric health care workers expressed significantly less burnout as compared to published MBI-HSS scores and client-related CBI scores. Personal burnout CBI scores were not different, but work-related CBI scores were significantly higher than normative scores. Copyright 2012, SLACK Incorporated.

  10. SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merritt, Z; Dave, J; Eschelman, D

    Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-areamore » product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.« less

  11. Who chooses prepaid dental care? A baseline report of a prospective observational study.

    PubMed

    Andås, Charlotte Andrén; Hakeberg, Magnus

    2014-12-03

    An optional capitation prepayment system has been implemented in Swedish dental care, supplementary to the traditional fee-for-service scheme within the Public Dental Service. The implementation of a new system may have a variety of preferred and adverse effects, arguably dependent on the individual patient's attitudes, health beliefs and course of action.The aim of this study was to describe potential differences regarding socioeconomic and lifestyle factors, perceived oral health and attitudes towards oral health between patients in the two payment systems. Questionnaire data were consecutively collected from 13,719 patients, who regularly attended 20 strategically selected clinics within the PDS in Region Västra Götaland, before they were offered the choice between the traditional and the new payment system. Capitation patients were more often female and well educated. They had healthier habits, were more motivated to follow self-care advice, more often judged their oral health to be very good and considered oral health to be very significant for their wellbeing. The results were statistically significant and described a gradient. The more explicitly affirmative the answer, the more likely the patient was to choose the prepayment scheme. There appears to be a pattern of differences with respect to important individual views on oral health between patients choosing a capitation system or a fee-for-service system. These differences may be important when assessing outcomes in the new payment system and in public dental care.

  12. A study of the relationship between the study process, motivation resources, and motivation problems of nursing students in different educational systems.

    PubMed

    Yardimci, Figen; Bektaş, Murat; Özkütük, Nilay; Muslu, Gonca Karayağız; Gerçeker, Gülçin Özalp; Başbakkal, Zümrüt

    2017-01-01

    The study process is related to students' learning approaches and styles. Motivation resources and problems determine students' internal, external, and negative motivation. Analyzing the study process and motivation of students yields important indications about the nature of educational systems in higher education. This study aims to analyze the relationship between the study process, and motivation resources and problems with regard to nursing students in different educational systems in Turkey and to reveal their effects according to a set of variables. This is a descriptive, cross-sectional and correlational study. Traditional, integrated and problem-based learning (PBL) educational programs for nurses involving students from three nursing schools in Turkey. Nursing students (n=330). The data were collected using the Study Process Questionnaire (R-SPQ-2F) and the Motivation Resources and Problems (MRP) Scale. A statistically significant difference was found between the scores on the study process scale, and motivation resources and problems scale among the educational systems. This study determined that the mean scores of students in the PBL system on learning approaches, intrinsic motivation and negative motivation were higher. A positive significant correlation was found between the scales. The study process, and motivation resources and problems were found to be affected by the educational system. This study determined that the PBL educational system more effectively increases students' intrinsic motivation and helps them to acquire learning skills. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The Stroop Effect in Kana and Kanji Scripts in Native Japanese Speakers: An fMRI Study

    PubMed Central

    Coderre, Emily L.; Filippi, Christopher G.; Newhouse, Paul A.; Dumas, Julie A.

    2008-01-01

    Prior research has shown that the two writing systems of the Japanese orthography are processed differently: kana (syllabic symbols) are processed like other phonetic languages such as English, while kanji (a logographic writing system) are processed like other logographic languages like Chinese. Previous work done with the Stroop task in Japanese has shown that these differences in processing strategies create differences in Stroop effects. This study investigated the Stroop effect in kanji and kana using functional magnetic resonance imaging (fMRI) to examine the similarities and differences in brain processing between logographic and phonetic languages. Nine native Japanese speakers performed the Stroop task both in kana and kanji scripts during fMRI. Both scripts individually produced significant Stroop effects as measured by the behavioral reaction time data. The imaging data for both scripts showed brain activation in the anterior cingulate gyrus, an area involved in inhibiting automatic processing. Though behavioral data showed no significant differences between the Stroop effects in kana and kanji, there were differential areas of activation in fMRI found for each writing system. In fMRI, the Stroop task activated an area in the left inferior parietal lobule during the kana task and the left inferior frontal gyrus during the kanji task. The results of the present study suggest that the Stroop task in Japanese kana and kanji elicits differential activation in brain regions involved in conflict detection and resolution for syllabic and logographic writing systems. PMID:18325582

  14. Effects of NiTi rotary and reciprocating instruments on debris and smear layer scores: an SEM evaluation.

    PubMed

    Poggio, Claudio; Dagna, Alberto; Chiesa, Marco; Scribante, Andrea; Beltrami, Riccardo; Colombo, Marco

    2014-12-30

    The purpose of the present study was to investigate the cleaning efficacy of 2 different nickel-titanium (NiTi) rotary systems: a new single system Reciproc compared with the rotary full sequence Mtwo. The amount of debris and the morphology of smear layer were the parameters for the evaluation of the cleanliness of root canals. The null hypothesis of the study was that there would be no significant difference in debris scores and smear layer scores between the 2 systems. 
 Forty single-rooted freshly extracted teeth were selected and divided into 2 groups. For each group, all root canals were shaped with 2 different NiTi instruments (Mtwo and Reciproc) and irrigated with 5.25% NaOCl and 17% ethylenediaminetetraacetic acid (EDTA) solutions by 3 trained operators. Specimens were fractured longitudinally and prepared for scanning electron microscopy (SEM) analysis at a standard magnification of ×5,000. The presence/absence of smear layer and the presence/absence of debris at the coronal, middle and apical third of each canal were evaluated using two 5-step scales for scores. Numeric data were analyzed using the Kruskal-Wallis and Mann-Whitney U statistical tests, and significance was set at a P value <0.05. 
 This study revealed significant differences among the various groups. The Mtwo group presented significantly lower smear layer scores than the Reciproc group (P<0.01) in the middle and apical third of the canal. 
 Conventional continuous rotary NiTi instruments associated with 5.25% NaOCl and 17% EDTA solutions seem to be better for obtaining clean dentinal canal walls. Reciprocating instruments leave a higher quantity of smear layer which covers dentinal walls and dentinal tubules.

  15. Topological Organization of Functional Brain Networks in Healthy Children: Differences in Relation to Age, Sex, and Intelligence

    PubMed Central

    Wu, Kai; Taki, Yasuyuki; Sato, Kazunori; Hashizume, Hiroshi; Sassa, Yuko; Takeuchi, Hikaru; Thyreau, Benjamin; He, Yong; Evans, Alan C.; Li, Xiaobo; Kawashima, Ryuta; Fukuda, Hiroshi

    2013-01-01

    Recent studies have demonstrated developmental changes of functional brain networks derived from functional connectivity using graph theoretical analysis, which has been rapidly translated to studies of brain network organization. However, little is known about sex- and IQ-related differences in the topological organization of functional brain networks during development. In this study, resting-state fMRI (rs-fMRI) was used to map the functional brain networks in 51 healthy children. We then investigated the effects of age, sex, and IQ on economic small-world properties and regional nodal properties of the functional brain networks. At a global level of whole networks, we found significant age-related increases in the small-worldness and local efficiency, significant higher values of the global efficiency in boys compared with girls, and no significant IQ-related difference. Age-related increases in the regional nodal properties were found predominately in the frontal brain regions, whereas the parietal, temporal, and occipital brain regions showed age-related decreases. Significant sex-related differences in the regional nodal properties were found in various brain regions, primarily related to the default mode, language, and vision systems. Positive correlations between IQ and the regional nodal properties were found in several brain regions related to the attention system, whereas negative correlations were found in various brain regions primarily involved in the default mode, emotion, and language systems. Together, our findings of the network topology of the functional brain networks in healthy children and its relationship with age, sex, and IQ bring new insights into the understanding of brain maturation and cognitive development during childhood and adolescence. PMID:23390528

  16. Effects of a Novel Fish Transport System on the Health of Adult Fall Chinook Salmon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, David R.; Colotelo, Alison H.; Linley, Timothy J.

    Movement past hydroelectric dams and related in-river structures has important implications for habitat connectivity and population persistence in migratory fish. A major problem is that many of these structures lack effective fish passage facilities, which can fragment spawning and rearing areas and negatively impact recruitment. While traditional fish passage facilities (e.g., ladders, trap and haul) can effectively enable fish to pass over barriers, their capital or operational costs can be significant. We evaluated the utility of a novel transport device that utilizes a flexible tube with differential internal air pressure to pass fish around in-river barriers. Three treatments and amore » control group were tested. In two of the treatments, adult fall Chinook Salmon nearing maturation were transported through the device via two lengths of tube (12 or 77 m) and their injury, stress, and immune system responses and reproductive function were compared to a third treatment where fish were moved by a standard trap and haul method and also to a control group. We observed no significant differences among the treatment or control groups in post-treatment adult survival, injury or stress. Indicators of immune system response and reproductive readiness were also not significantly different among the four groups. Egg survival was significantly different among the groups, but the differences were highly variable within groups and not consistent with the duration of treatment or degree of handling. Taken together, the results suggest the device did not injure or alter normal physiological functioning of adult fall Chinook Salmon nearing maturation and may provide an effective method for transporting such fish around in-river barriers during their spawning migration. Keywords: Whooshh, transport, in-stream barriers, hydropower« less

  17. Topological organization of functional brain networks in healthy children: differences in relation to age, sex, and intelligence.

    PubMed

    Wu, Kai; Taki, Yasuyuki; Sato, Kazunori; Hashizume, Hiroshi; Sassa, Yuko; Takeuchi, Hikaru; Thyreau, Benjamin; He, Yong; Evans, Alan C; Li, Xiaobo; Kawashima, Ryuta; Fukuda, Hiroshi

    2013-01-01

    Recent studies have demonstrated developmental changes of functional brain networks derived from functional connectivity using graph theoretical analysis, which has been rapidly translated to studies of brain network organization. However, little is known about sex- and IQ-related differences in the topological organization of functional brain networks during development. In this study, resting-state fMRI (rs-fMRI) was used to map the functional brain networks in 51 healthy children. We then investigated the effects of age, sex, and IQ on economic small-world properties and regional nodal properties of the functional brain networks. At a global level of whole networks, we found significant age-related increases in the small-worldness and local efficiency, significant higher values of the global efficiency in boys compared with girls, and no significant IQ-related difference. Age-related increases in the regional nodal properties were found predominately in the frontal brain regions, whereas the parietal, temporal, and occipital brain regions showed age-related decreases. Significant sex-related differences in the regional nodal properties were found in various brain regions, primarily related to the default mode, language, and vision systems. Positive correlations between IQ and the regional nodal properties were found in several brain regions related to the attention system, whereas negative correlations were found in various brain regions primarily involved in the default mode, emotion, and language systems. Together, our findings of the network topology of the functional brain networks in healthy children and its relationship with age, sex, and IQ bring new insights into the understanding of brain maturation and cognitive development during childhood and adolescence.

  18. Electronic health record systems in ophthalmology: impact on clinical documentation.

    PubMed

    Sanders, David S; Lattin, Daniel J; Read-Brown, Sarah; Tu, Daniel C; Wilson, David J; Hwang, Thomas S; Morrison, John C; Yackel, Thomas R; Chiang, Michael F

    2013-09-01

    To evaluate quantitative and qualitative differences in documentation of the ophthalmic examination between paper and electronic health record (EHR) systems. Comparative case series. One hundred fifty consecutive pairs of matched paper and EHR notes, documented by 3 attending ophthalmologist providers. An academic ophthalmology department implemented an EHR system in 2006. Database queries were performed to identify cases in which the same problems were documented by the same provider on different dates, using paper versus EHR methods. This was done for 50 consecutive pairs of examinations in 3 different diseases: age-related macular degeneration (AMD), glaucoma, and pigmented choroidal lesions (PCLs). Quantitative measures were used to compare completeness of documenting the complete ophthalmologic examination, as well as disease-specific critical findings using paper versus an EHR system. Qualitative differences in paper versus EHR documentation were illustrated by selecting representative paired examples. (1) Documentation score, defined as the number of examination elements recorded for the slit-lamp examination, fundus examination, and complete ophthalmologic examination and for critical clinical findings for each disease. (2) Paired comparison of qualitative differences in paper versus EHR documentation. For all 3 diseases (AMD, glaucoma, PCL), the number of complete examination findings recorded was significantly lower with paper than the EHR system (P ≤ 0.004). Among the 3 individual examination sections (general, slit lamp, fundus) for the 3 diseases, 5 of the 9 possible combinations had significantly lower mean documentation scores with paper than EHR notes. For 2 of the 3 diseases, the number of critical clinical findings recorded was significantly lower using paper versus EHR notes (P ≤ 0.022). All (150/150) paper notes relied on graphical representations using annotated hand-drawn sketches, whereas no (0/150) EHR notes contained drawings. Instead, the EHR systems documented clinical findings using textual descriptions and interpretations. There were quantitative and qualitative differences in the nature of paper versus EHR documentation of ophthalmic findings in this study. The EHR notes included more complete documentation of examination elements using structured textual descriptions and interpretations, whereas paper notes used graphical representations of findings. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Mainstream and Non-Mainstream Communication Norms.

    ERIC Educational Resources Information Center

    Kochman, Thomas

    This document discusses significant differences between the cultural personalities and communication patterns of non-mainstream and mainstream groups in an effort to understand the nature and cause of conflict between groups. The author seeks to identify the "combustible" features of different communication systems, to demonstrate the systematic…

  20. Information Society and the Transformation of Organizations in Finland.

    ERIC Educational Resources Information Center

    Blom, Raimo; Melin, Harri

    2003-01-01

    Case studies of three Finnish companies (involved in manufacturing, Internet catalogs, and municipal government services) were used to investigate the nature of organizational change. Significant differences among organizational types were apparent in team formation, pay systems, recruitment, and forms of control. Organization differences reflect…

  1. Professional Diversity in Libraries.

    ERIC Educational Resources Information Center

    Kaufman, Paula T.

    1992-01-01

    Outlines issues of concern in the management of nonlibrarian professionals in research libraries, argued to be significantly different from the management of professional librarians. Differing professional value systems, conflicts and tension that can arise, and organizational teamwork are discussed with a focus on effective reward structures. (15…

  2. Use of a vision model to quantify the significance of factors effecting target conspicuity

    NASA Astrophysics Data System (ADS)

    Gilmore, M. A.; Jones, C. K.; Haynes, A. W.; Tolhurst, D. J.; To, M.; Troscianko, T.; Lovell, P. G.; Parraga, C. A.; Pickavance, K.

    2006-05-01

    When designing camouflage it is important to understand how the human visual system processes the information to discriminate the target from the background scene. A vision model has been developed to compare two images and detect differences in local contrast in each spatial frequency channel. Observer experiments are being undertaken to validate this vision model so that the model can be used to quantify the relative significance of different factors affecting target conspicuity. Synthetic imagery can be used to design improved camouflage systems. The vision model is being used to compare different synthetic images to understand what features in the image are important to reproduce accurately and to identify the optimum way to render synthetic imagery for camouflage effectiveness assessment. This paper will describe the vision model and summarise the results obtained from the initial validation tests. The paper will also show how the model is being used to compare different synthetic images and discuss future work plans.

  3. A Pilot Study of Gait Function in Farmworkers in Eastern North Carolina.

    PubMed

    Nguyen, Ha T; Kritchevsky, Stephen B; Foxworth, Judy L; Quandt, Sara A; Summers, Phillip; Walker, Francis O; Arcury, Thomas A

    2015-01-01

    Farmworkers endure many job-related hazards, including fall-related work injuries. Gait analysis may be useful in identifying potential fallers. The goal of this pilot study was to explore differences in gait between farmworkers and non-farmworkers. The sample included 16 farmworkers and 24 non-farmworkers. Gait variables were collected using the portable GAITRite system, a 16-foot computerized walkway. Generalized linear regression models were used to examine group differences. All models were adjusted for two established confounders, age and body mass index. There were no significant differences in stride length, step length, double support time, and base of support; but farmworkers had greater irregularity of stride length (P = .01) and step length (P = .08). Farmworkers performed significantly worse on gait velocity (P = .003) and cadence (P < .001) relative to non-farmworkers. We found differences in gait function between farmworkers and non-farmworkers. These findings suggest that measuring gait with a portable walkway system is feasible and informative in farmworkers and may possibly be of use in assessing fall risk.

  4. Comparison of standard (self-directed) versus intensive patient training for the human insulin inhalation powder (HIIP) delivery system in patients with type 2 diabetes: efficacy, safety, and training measures.

    PubMed

    Rosenstock, Julio; Nakano, Masako; Silverman, Bernard L; Sun, Bin; de la Peña, Amparo; Suri, Ajit; Muchmore, Douglas B

    2007-02-01

    The Lilly/Alkermes human insulin inhalation powder (HIIP) delivery system [AIR (a registered trademark of Alkermes, Inc., Cambridge, MA) Inhaled Insulin System] was designed to be easy to use. Training methods were compared in insulin-naive patients with type 2 diabetes. Patients (n = 102) were randomized to standard or intensive training. With standard training, patients learned how to use the HIIP delivery system by reading directions for use (DFU) and trying on their own. Intensive training included orientation to the HIIP delivery system with individual coaching and inspiratory flow rate training. Both groups received preprandial HIIP + metformin with or without a thiazolidinedione for 4 weeks. Overall 2-h postprandial blood glucose (PPBG) excursion was the primary measure. Noninferiority was defined as the upper limit of the two-sided 95% confidence interval of the mean difference between groups being 1.2 < or = mmol/L. Overall 2-h PPBG excursions (least squares mean +/- SE) at endpoint were -0.11 +/- 0.38 (standard training) and 0.23 +/- 0.36 (intensive training) mmol/L. The mean difference (standard minus intensive training) and two-sided 95% confidence interval were -0.35 (-1.02, 0.33) mmol/L. No statistically or clinically significant differences were observed between training methods in premeal, postmeal, or bedtime blood glucose values, HIIP doses at endpoint, or blood glucose values after a test meal. No discontinuations occurred because of difficulty of use or dislike of the HIIP system. DFU compliance was >90% in both training groups. There were no significant differences between training methods in safety measures. The HIIP delivery system is easy to use, and most patients can learn to use it by reading the DFU without assistance from health care professionals.

  5. A Risk Score Model for Evaluation and Management of Patients with Thyroid Nodules.

    PubMed

    Zhang, Yongwen; Meng, Fanrong; Hong, Lianqing; Chu, Lanfang

    2018-06-12

    The study is aimed to establish a simplified and practical tool for analyzing thyroid nodules. A novel risk score model was designed, risk factors including patient history, patient characteristics, physical examination, symptoms of compression, thyroid function, ultrasonography (US) of thyroid and cervical lymph nodes were evaluated and classified into high risk factors, intermediate risk factors, and low risk factors. A total of 243 thyroid nodules in 162 patients were assessed with risk score system and Thyroid Imaging-Reporting and Data System (TI-RADS). The diagnostic performance of risk score system and TI-RADS was compared. The accuracy in the diagnosis of thyroid nodules was 89.3% for risk score system, 74.9% for TI-RADS respectively. The specificity, accuracy and positive predictive value (PPV) of risk score system were significantly higher than the TI-RADS system (χ 2 =26.287, 17.151, 11.983; p <0.05), statistically significant differences were not observed in the sensitivity and negative predictive value (NPV) between the risk score system and TI-RADS (χ 2 =1.276, 0.290; p>0.05). The area under the curve (AUC) for risk score diagnosis system was 0.963, standard error 0.014, 95% confidence interval (CI)=0.934-0.991, the AUC for TI-RADS diagnosis system was 0.912 with standard error 0.021, 95% CI=0.871-0.953, the AUC for risk score system was significantly different from that of TI-RADS (Z=2.02; p <0.05). Risk score model is a reliable, simplified and cost-effective diagnostic tool used in diagnosis of thyroid cancer. The higher the score is, the higher the risk of malignancy will be. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Influence of sugarbeet tillage Systems on the rhizoctonia-bacterial root rot complex

    USDA-ARS?s Scientific Manuscript database

    The Rhizoctonia-bacterial root rot complex in sugarbeet caused by Rhizoctonia solani and Leuconostoc mesenteroides can cause significant yield losses. To investigate the impact of different tillage systems on this complex, field studies were conducted from 2009 to 2011. Split blocks with conventio...

  7. Influence of sugarbeet tillage systems on rhizoctonia-bacterial root rot complex

    USDA-ARS?s Scientific Manuscript database

    The Rhizoctonia-bacterial root rot complex on sugarbeet caused by Rhizoctonia solani and Leuconostoc mesenteroides can cause significant yield losses. To investigate the impact of different tillage systems on this complex, field studies were conducted from 2009 to 2011. Split blocks with conventio...

  8. Comparative Analysis of Linguists' Professional Training at British and Ukrainian Universities

    ERIC Educational Resources Information Center

    Komochkova, Olga

    2017-01-01

    We have performed comparative analysis on professional training of linguists at British and Ukrainian universities at administrative and managerial, legislative, organizational and pedagogical, systemic, conceptual, socioeconomic levels. As evidenced above, British and Ukrainian systems of professional training of linguists differ significantly,…

  9. 14C-labeled organic amendments: Characterization in different particle size fractions and humic acids in a long-term field experiment

    PubMed Central

    Tatzber, Michael; Stemmer, Michael; Spiegel, Heide; Katzlberger, Christian; Landstetter, Claudia; Haberhauer, Georg; Gerzabek, Martin H.

    2012-01-01

    Knowledge about the stabilization of organic matter input to soil is essential for understanding the influence of different agricultural practices on turnover characteristics in agricultural soil systems. In this study, soil samples from a long-term field experiment were separated into silt- and clay-sized particles. In 1967, 14C labeled farmyard manure was applied to three different cropping systems: crop rotation, monoculture and permanent bare fallow. Humic acids (HAs) were extracted from silt- and clay-sized fractions and characterized using photometry, mid-infrared and fluorescence spectroscopy. Remaining 14C was determined in size fractions as well as in their extracted HAs. Yields of carbon and remaining 14C in HAs from silt-sized particles and Corg in clay-sized particles decreased significantly in the order: crop rotation > monoculture ≫ bare fallow. Thus, crop rotation not only had the largest overall C-pool in the experiment, but it also best stabilized the added manure. Mid-infrared spectroscopy could distinguish between HAs from different particle size soil fractions. With spectroscopic methods significant differences between the cropping systems were detectable in fewer cases compared to quantitative results of HAs (yields, 14C, Corg and Nt). The trends, however, pointed towards increased humification of HAs from bare fallow systems compared to crop rotation and monoculture as well as of HAs from clay-sized particles compared to silt-sized particles. Our study clearly shows that the largest differences were observed between bare fallow on one hand and monoculture and crop rotation on the other. PMID:23482702

  10. Impaired or Not Impaired, That Is the Question: Navigating the Challenges Associated with Using Canadian Normative Data in a Comprehensive Test Battery That Contains American Tests

    PubMed Central

    Chevalier, Thérèse M.; Stewart, Garth; Nelson, Monty; McInerney, Robert J.; Brodie, Norman

    2016-01-01

    It has been well documented that IQ scores calculated using Canadian norms are generally 2–5 points lower than those calculated using American norms on the Wechsler IQ scales. However, recent findings have demonstrated that the difference may be significantly larger for individuals with certain demographic characteristics, and this has prompted discussion about the appropriateness of using the Canadian normative system with a clinical population in Canada. This study compared the interpretive effects of applying the American and Canadian normative systems in a clinical sample. We used a multivariate analysis of variance (ANOVA) to calculate differences between IQ and Index scores in a clinical sample, and mixed model ANOVAs to assess the pattern of differences across age and ability level. As expected, Full Scale IQ scores calculated using Canadian norms were systematically lower than those calculated using American norms, but differences were significantly larger for individuals classified as having extremely low or borderline intellectual functioning when compared with those who scored in the average range. Implications of clinically different conclusions for up to 52.8% of patients based on these discrepancies highlight a unique dilemma facing Canadian clinicians, and underscore the need for caution when choosing a normative system with which to interpret WAIS-IV results in the context of a neuropsychological test battery in Canada. Based on these findings, we offer guidelines for best practice for Canadian clinicians when interpreting data from neuropsychological test batteries that include different normative systems, and suggestions to assist with future test development. PMID:27246955

  11. 14C-labeled organic amendments: Characterization in different particle size fractions and humic acids in a long-term field experiment.

    PubMed

    Tatzber, Michael; Stemmer, Michael; Spiegel, Heide; Katzlberger, Christian; Landstetter, Claudia; Haberhauer, Georg; Gerzabek, Martin H

    2012-05-01

    Knowledge about the stabilization of organic matter input to soil is essential for understanding the influence of different agricultural practices on turnover characteristics in agricultural soil systems. In this study, soil samples from a long-term field experiment were separated into silt- and clay-sized particles. In 1967, 14 C labeled farmyard manure was applied to three different cropping systems: crop rotation, monoculture and permanent bare fallow. Humic acids (HAs) were extracted from silt- and clay-sized fractions and characterized using photometry, mid-infrared and fluorescence spectroscopy. Remaining 14 C was determined in size fractions as well as in their extracted HAs. Yields of carbon and remaining 14 C in HAs from silt-sized particles and C org in clay-sized particles decreased significantly in the order: crop rotation > monoculture ≫ bare fallow. Thus, crop rotation not only had the largest overall C-pool in the experiment, but it also best stabilized the added manure. Mid-infrared spectroscopy could distinguish between HAs from different particle size soil fractions. With spectroscopic methods significant differences between the cropping systems were detectable in fewer cases compared to quantitative results of HAs (yields, 14 C, C org and N t ). The trends, however, pointed towards increased humification of HAs from bare fallow systems compared to crop rotation and monoculture as well as of HAs from clay-sized particles compared to silt-sized particles. Our study clearly shows that the largest differences were observed between bare fallow on one hand and monoculture and crop rotation on the other.

  12. Health Conditions and Racial Differences Among Justice-Involved Adolescents, 2009 to 2014.

    PubMed

    Winkelman, Tyler N A; Frank, Joseph W; Binswanger, Ingrid A; Pinals, Debra A

    Providers can optimize care for high-risk adolescents by understanding the health risks among the 1 million US adolescents who interact with the justice system each year. We compared the prevalence of physical health, substance use, and mood disorders among adolescents with and without recent justice involvement and analyzed differences according to race/ethnicity. Cross-sectional analysis using the 2009 to 2014 National Survey on Drug Use and Health. Prevalence data were adjusted for sociodemographic differences between adolescents with and without justice involvement. Justice-involved adolescents had a history of past year arrest, parole/probation, or juvenile detention. Our sample consisted of adolescents aged 12 to 17 years with (n = 5149) and without (n = 97,976) past year justice involvement. In adjusted analyses, adolescents involved at any level of the justice system had a significantly higher prevalence of substance use disorders (P < .001), mood disorders (P < .001), and sexually transmitted infections (P < .01). Adolescents on parole/probation or in juvenile detention in the past year had a higher prevalence of asthma (P < .05) and hypertension (P < .05) compared with adolescents without justice involvement. Among justice-involved adolescents, African American adolescents were significantly less likely to have a substance use disorder (P < .001) or mood disorder (P < .01) compared with white or Hispanic adolescents, but had significantly higher prevalence of physical health disorders (P < .01). Adolescents involved at all levels of the justice system have high-risk health profiles compared with the general adolescent population, although these risks differ across racial/ethnic groups. Policymakers and health care providers should ensure access to coordinated, high-quality health care for adolescents involved at all levels of the justice system. Published by Elsevier Inc.

  13. Incision properties and thermal effects of CO2 lasers in soft tissue

    NASA Astrophysics Data System (ADS)

    Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.; Liaw, Lih-Huei L.; Berns, Michael W.

    1995-05-01

    Thermal and histological events resulting from soft tissue incision using CO2 lasers at 9.3 (mu) or 10.6 (mu) , fitted with a hollow wave guide or an articulated arm delivery system respectively, were investigated. In 9 fresh pigs' mandibles, standardized incisions 3 cm in length were made in the oral mucosa. Incisions were performed in the cw mode at 1 W, 4 W, and 12 W. Thermal events were measured in adjacent soft tissues using thermocouples. Incisions were dissected out, fixed, embedded in paraffin wax, sectioned and stained with Serius Red. The Students' t-test for paired data was used to compare zones of necrosis, zones of collagen damage and thermal events. No significant temperature rise was measured during irradiation at any timepoints or power settings (p < 0.05). Results were very similar for the two lasers with significantly different results obtained only at the 12 W setting (p < 0.05). Vertical incision depths and horizontal incision widths did not differ significantly (p < 0.0001) at 12 W and 4 W. Horizontal and vertical zones of necrosis did not differ significantly (p < 0.0001) either between the two lasers at 12 W and 4 W. Thus the thermal and histological events occurring during soft tissue incision were similar using these two lasers, despite the difference in wavelength and delivery system.

  14. A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible-A preliminary study.

    PubMed

    Makowiecki, Arkadiusz; Botzenhart, Ute; Seeliger, Julia; Heinemann, Friedhelm; Biocev, Peter; Dominiak, Marzena

    2017-07-01

    The objective of the present study was to compare the primary and secondary stability of tissue-level short dental titanium implants with polished necks and hydrophilic surfaces of two different designs and manufacturers. The first implant system used (SPI ® ELEMENT RC INICELL titanium implants, Thommen Medical AG, Grenchen, Switzerland), allowed functional loading 6 weeks after its placement, whereas the second implant system (RN SLActiv ® tissue-level titanium implants, Straumann GmbH, Fribourg, Germany), was loaded after 15 weeks. The degree of primary and secondary stability was determined using an Osstell ISQ measuring device. Marginal bone loss (MBL) was evaluated radiographically 12 and 24 weeks after implantation and the Wachtel's healing index as well as the patient's satisfaction with the treatment was registered on a VAS scale. The intergroup comparison revealed significant differences in terms of primary stability as well as differences in MBL 3 months after the procedure, but no significant differences could be found after 6 months and for secondary stability. The primary stability was significantly higher for Thommen ® compared to Straumann ® implants. Insertion of short dental implants with a hydrophilic conditioned surface significantly shortens patient treatment time. Copyright © 2017 Elsevier GmbH. All rights reserved.

  15. Characteristics of Low-Priced Solar Photovoltaic Systems in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemet, Gregory F.; O'Shaughnessy, Eric; Wiser, Ryan H.

    2016-01-01

    Despite impressive recent cost reductions, there is wide dispersion in the prices of installed solar photovoltaic (PV) systems. We identify the most important factors that make a system likely to be low priced (LP). Our sample consists of detailed characteristics for 42,611 small-scale (< 15 kW) PV systems installed in 15 U.S. states during 2013. Using four definitions of LP systems, we compare LP and non-LP systems and find statistically significant differences in nearly all factors explored, including competition, installer scale, markets, demographics, ownership, policy, and system components. Logit and probit model results robustly indicate that LP systems are associatedmore » with markets with few active installers; experienced installers; customer ownership; large systems; retrofits; and thin-film, low-efficiency, and Chinese modules. We also find significant differences across states, with LP systems much more likely to occur in some than in others. Our focus on the left tail of the price distribution provides implications for policy that are distinct from recent studies of mean prices. While those studies find that PV subsidies increase mean prices, we find that subsidies also generate LP systems. PV subsidies appear to simultaneously shift and broaden the price distribution. Much of this broadening occurs in a particular location, northern California, which is worthy of further investigation with new data.« less

  16. Biomechanical comparison of locked versus non-locked symphyseal plating of unstable pelvic ring injuries.

    PubMed

    Godinsky, R J; Vrabec, G A; Guseila, L M; Filipkowski, D E; Elias, J J

    2018-04-01

    Locked symphyseal plates are utilized to provide higher levels of construct stiffness than non-locked plates. The current biomechanical study was performed to compare stiffness at the pubic symphysis between locked and non-locked plating systems. Synthetic models were utilized to represent injury to the pelvis and symphyseal plating combined with a sacro-iliac screw. Seven models were evaluated with plates and locking screws, and seven were evaluated with non-locking screws. Single limb stance was simulated, with all models loaded for 1000 cycles with 350 N applied at the sacrum. Two pairs of markers crossing the symphysis were tracked with a video-based tracking system. A coordinate system was developed to quantify motion between the pairs in three directions: medial-lateral gap, anterior-posterior shear translation, and superior-inferior shear translation. Significant differences between the plating systems were identified with t tests (p < 0.05). Anterior-posterior shear translation varied significantly between the two plating systems. From cycles 100 to 1000, average shear translation for the non-locked and locked systems was ~0.7 and 0.3 mm, respectively, at the markers closest to the plate and 2.2 and 1.4 mm, respectively, at the markers further from the plate. Motion in the other two directions did not differ significantly between locked and non-locked models. Locked symphyseal plating systems can provide better stability than non-locked systems for anterior-posterior shear translation. More stability could potentially reduce the risk of failure of the plate or screws.

  17. Compare the efficacy of inhaled budesonide and systemic methylprednisolone on systemic inflammation of AECOPD.

    PubMed

    Sun, Xuejiao; He, Zhiyi; Zhang, Jianquan; Deng, Jingmin; Bai, Jing; Li, Meihua; Zhong, Xiaoning

    2015-04-01

    Corticosteroids have been shown to improve the outcome of acute exacerbation of chronic obstructive pulmonary disease (AECOPD). However, whether inhaled corticosteroids (IC) alone have similar effects with systemic corticosteroid (SCS) is still unclear. To compare the efficacy of inhaled budesonide and systemic methylprednisolone on systemic inflammation of AECOPD. 30 AECOPD patients were randomly divided into two group. Budesonide group (15 cases) were treated with inhaled budesonide (3 mg Bid); methylprednisolone group (15 cases) were treated with systemic methylprednisolone (methylprednisolone acetate injectable suspension 40 mg Qd for three days and then methylprednisolone tablets 8 mg Bid). Observe symptoms, lung function, blood gas analysis and adverse effects of the patients in two groups. Peripheral blood samples were collected before and after treatment for 1 day, 4 days and 7 days. Interleukin-8 (IL-8) and TNF-α levels were determined by an enzyme linked immunosorbent assay (ELISA). Hs-CRP levels were detected by automatic biochemical analyzer. Western blotting was used to determine histone deacetylase 2 (HDAC2) protein expression. Symptoms, pulmonary function and blood gas analysis were significantly improved after treatment in the two groups (P < 0.05) and no significant differences between the two groups (P > 0.05). There were no significant differences of IL-8, TNF-α and hs-CRP levels in the two groups (P > 0.05). Besides, the levels of HDAC2 protein expression before treatment were significantly lower comparing to that after treatment for 4 and 7 days. Incidence of adverse events (heart rate, blood pressure, glycemic, sleep condition, gastrointestinal symptoms) in budesonide group was lower than methylprednisolone group (P < 0.05). Inhaled budesonide and systemic methylprednisolone have the same effects on systemic inflammation of AECOPD. Inhaled corticosteroid alone could instead systemic corticosteroid in AECOPD treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Well clear: General aviation and commercial pilots' perception of unmanned aerial vehicles in the national airspace system

    NASA Astrophysics Data System (ADS)

    Ott, Joseph T.

    The purpose of this research was to determine how different pilot types perceived the subjective concept of the Well Clear Boundary (WCB) and to observe if that boundary changed when dealing with manned versus unmanned aircraft systems (UAS) as well as the effects of other variables. Pilots' perceptions of the WCB were collected objectively through simulator recordings and subjectively through questionnaires. Together, these metrics provided quantitative and qualitative data about pilot WCB perception. The objective results of this study showed significant differences in WCB perception between two different pilot types, as well as WCB significant differences when comparing two different intruder types (manned versus unmanned aircraft). These differences were dependent on other manipulated variables, including intruder approach angle, ownship speed, and background traffic levels. Subjectively, there were evident differences in WCB perception across pilot types; general aviation (GA) pilots appeared to trust UAS aircraft slightly more than did the more experienced Airline Transport Pilots (ATPs). Overall, it is concluded that pilots' mental models of the WCB are more easily perceived as time-based boundaries in front of ownship, while being more easily perceived as distance-based boundaries to the rear of ownship.

  19. Comparison of Two Different Ultrasound Devices Using Strain Elastography Technology in the Diagnosis of Breast Lesions Related to the Histologic Results.

    PubMed

    Farrokh, André; Schaefer, Fritz; Degenhardt, Friedrich; Maass, Nicolai

    2018-05-01

    This study was conducted to provide evidence that elastograms of two different devices and different manufacturers using the same technical approach provide the same diagnoses. A total of 110 breast lesions were prospectively analysed by two experts in ultrasound, using the strain elastography function from two different manufacturers (Hitachi HI-RTE, Hitachi Medical Systems, Wiesbaden, Germany; and Siemens eSie Touch, Siemens Medical Systems, Erlangen, Germany). Results were compared with the histopathologic results. Applying the Bowker test of symmetry, no statistically significant difference between the two elastography functions of these two devices was found (p = 0.120). The Cohen's kappa of k = 0.591 showed moderate strength of agreement between the two elastograms. The two examiners yielded moderate strength of agreement analysing the elastograms (Hitachi HI-RTE, k = 0.478; Siemens eSie Touch, k = 0.441). In conclusion, evidence is provided that elastograms of the same lesion generated by two different ultrasound devices equipped with a strain elastography function do not significantly differ. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  20. Biomechanical analysis of three tennis serve types using a markerless system.

    PubMed

    Abrams, Geoffrey D; Harris, Alex H S; Andriacchi, Thomas P; Safran, Marc R

    2014-02-01

    The tennis serve is commonly associated with musculoskeletal injury. Advanced players are able to hit multiple serve types with different types of spin. No investigation has characterised the kinematics of all three serve types for the upper extremity and back. Seven NCAA Division I male tennis players performed three successful flat, kick and slice serves. Serves were recorded using an eight camera markerless motion capture system. Laser scanning was utilised to accurately collect body dimensions and data were computed using inverse kinematic methods. There was no significant difference in maximum back extension angle for the flat, kick or slice serves. The kick serve had a higher force magnitude at the back than the flat and slice as well as larger posteriorly directed shoulder forces. The flat serve had significantly greater maximum shoulder internal rotation velocity versus the slice serve. Force and torque magnitudes at the elbow and wrist were not significantly different between the serves. The kick serve places higher physical demands on the back and shoulder while the slice serve demonstrated lower overall kinetic forces. This information may have injury prevention and rehabilitation implications.

Top