Sample records for system weight volume

  1. Weight/volume ratios for Appalachian hardwoods

    Treesearch

    Floyd G. Timson

    1975-01-01

    Weight/volume relationships are presented in both English and metric systems for 15 commercial species of Appalachian hardwoods. Two ratios are presented: weight of wood volume alone, and weight of wood plus bark.

  2. Program Manual for Producing Weight Scaling Conversion Tables

    Treesearch

    Gary L. Tyre; Clyde A. Fasick; Frank M. Riley; Frank O. Lege

    1973-01-01

    Three computer programs are presented which can be applied by individual firms to establish a weight-scaling information system, The first generates volume estimates from truckload weights for any combination of veneer, sawmill, and pulpwood volumes. The second provides quality-control information by tabulating differences between estimated volumes and observed check-...

  3. Research on Volume Measurement System of Weights with Hydrostatic Technique

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Ren, Xiaoping; Yao, Hong; Cai, Changqing; Zhang, Yue; Zhong, Ruilin; Ding, Jing'an

    According to Annex B.7.4 of OIML R111-1, equipment for measuring volume of weights mass ranging from 1 kg to 20 kg including three methods of hydrostatic comparison is described. The equipment consists of a robot arm for transferring weights, a liquid bath, a mass comparator with 26.1 kg of maximum capacity and 1 mg of readability, glass housing, two weight exchangers including in air and in liquid, two weight holders including in air and in liquid, and a controller. The equipment will enable to perform automatically volume measurements.

  4. Short communication: Measuring feed volume and weight by machine vision.

    PubMed

    Shelley, A N; Lau, D L; Stone, A E; Bewley, J M

    2016-01-01

    Individual dairy cow feed intake is closely related to the health and productive output of each cow, with healthy cows generally eating more feed than unhealthy cows. Incorporating the use of an automated system to monitor feed consumption for each cow may be beneficial for dairy farm management. This study examined the use of an inexpensive 3-dimensional video camera to measure feed volume, from which we derived feed weight. Proof-of-concept testing was conducted to determine the effectiveness and capability of the machine vision feed-scanning system and its possible use in feed intake monitoring. Such systems are ideal because they do not impede the workflow of the farm or interrupt feeding behavior. This is an improvement over existing systems that are labor and cost intensive. Our conducted experiments involve measuring feed volume at known weights, up to 22.68 kg, with the resulting volume and weight values analyzed by means of linear and quadratic least squares t-test regression analysis. The effects of feed positioning in the bin and near-range sensor limitations were also examined. The results showed that an estimation of feed weight from 3-dimensional scan of volume measurements could be made to within 0.5 kg of the physically measured feed weight using a digital scale. Future efforts will focus on extending this work to active bunks with multiple cows eating throughout the day and testing total mixed rations of varied composition. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Space Transportatioin System (STS) propellant scavenging system study. Volume 3: Cost and work breakdown structure-dictionary

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Fundamentally, the volumes of the oxidizer and fuel propellant scavenged from the orbiter and external tank determine the size and weight of the scavenging system. The optimization of system dimensions and weights is stimulated by the requirement to minimize the use of partial length of the orbiter payload bay. Thus, the cost estimates begin with weights established for the optimum design. Both the design, development, test, and evaluation and theoretical first unit hardware production costs are estimated from parametric cost weight scaling relations for four subsystems. For cryogenic propellants, the widely differing characteristics of the oxidizer and the fuel lead to two separate tank subsystems, in addition to the electrical and instrumentation subsystems. Hardwares costs also involve quantity, as an independent variable, since the number of production scavenging systems is not firm. For storable propellants, since the tankage volume of the oxidizer and fuel are equal, the hardware production costs for developing these systems are lower than for cryogenic propellants.

  6. Ground Vehicle System Integration (GVSI) and Design Optimization Model.

    DTIC Science & Technology

    1996-07-30

    number of stowed kills Same basic load lasts longer range Gun/ammo parameters impact system weight, under - armor volume requirements Round volume...internal volume is reduced, the model assumes that the crew’s ability to operate while under armor will be impaired. If the size of a vehicle crew is...changing swept volume will alter under armor volume requirements for the total system; if system volume is fixed, changing swept volume will

  7. Automotive Manufacturing Assessment System : Volume 3. Materials - Weight Analysis.

    DOT National Transportation Integrated Search

    1979-11-01

    Volume III is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of ...

  8. Advanced Extravehicular Protective Systems (AEPS) study

    NASA Technical Reports Server (NTRS)

    Williams, J. L.; Copeland, R. J.; Webbon, B. W.

    1971-01-01

    A description is given of life support subsystem concepts for advanced extravehicular protective systems (AEPS) intended for use on future orbital, lunar surface, and Mars surface missions in the late 1970's and 1980's. Primary interest was centered around the thermal control and carbon dioxide control subsystems because they offer the greatest potential for total weight savings. Emphasis was placed on the generation of regenerable subsystem concepts; however, partially regenerable and expendable concepts were also considered. Previously conceived and developed subsystem concepts were included in the study. Concepts were evaluated on the basis of subsystem weight and volume, and subsystem contribution to parent vehicle weight and volume, which included spares, regeneration equipment, expendables, expandables storage penalty, power penalty, and process heating or cooling penalty. Results are presented showing total weight and volume penalty as a function of total mission extravehicular activity (EVA) hours, and showing EVA weight and volume as a function of EVA duration. Subsystem concepts are recommended for each life support function, and secondary concepts which should be developed are also identified.

  9. A Compatible Stem Taper-Volume-Weight System For Intensively Managed Fast Growing Loblolly Pine

    Treesearch

    Yugia Zhang; Bruce E. Borders; Robert L Bailey

    2002-01-01

    eometry-oriented methodology yielded a compatible taper-volume-weight system of models whose parameters were estimated using data from intensively managed loblolly pine (Pinus taeda L.) plantations in the lower coastal plain of Georgia. Data analysis showed that fertilization has significantly reduced taper (inside and outside bark) on the upper...

  10. Ballast system for maintaining constant pressure in a glove box

    NASA Technical Reports Server (NTRS)

    Shlichta, Paul J. (Inventor)

    1989-01-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  11. Ballast system for maintaining constant pressure in a glove box

    NASA Astrophysics Data System (ADS)

    Shlichta, Paul J.

    1989-09-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  12. Ballast system for maintaining constant pressure in a glove box

    NASA Technical Reports Server (NTRS)

    Shlichta, Paul J. (Inventor)

    1990-01-01

    A ballast system for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  13. Optimal trajectories for hypersonic launch vehicles

    NASA Technical Reports Server (NTRS)

    Ardema, Mark D.; Bowles, Jeffrey V.; Whittaker, Thomas

    1994-01-01

    In this paper, we derive a near-optimal guidance law for the ascent trajectory from earth surface to earth orbit of a hypersonic, dual-mode propulsion, lifting vehicle. Of interest are both the optical flight path and the optimal operation of the propulsion system. The guidance law is developed from the energy-state approximation of the equations of motion. Because liquid hydrogen fueled hypersonic aircraft are volume sensitive, as well as weight sensitive, the cost functional is a weighted sum of fuel mass and volume; the weighting factor is chosen to minimize gross take-off weight for a given payload mass and volume in orbit.

  14. Multifunctional Inflatable Structure Being Developed for the PowerSphere Concept

    NASA Technical Reports Server (NTRS)

    Peterson, Todd T.

    2003-01-01

    The continuing development of microsatellites and nanosatellites for low Earth orbits requires the collection of sufficient power for instruments onboard a low-weight, low-volume spacecraft. Because the overall surface area of a microsatellite or nanosatellite is small, body-mounted solar cells cannot provide enough power. The deployment of traditional, rigid, solar arrays necessitates larger satellite volumes and weights, and also requires extra apparatus for pointing. One solution to this power choke problem is the deployment of a spherical, inflatable power system. This power system, termed the "PowerSphere," has several advantages, including a high collection area, low weight and stowage volume, and the elimination of solar array pointing mechanisms.

  15. 2007 Joint Service Power Expo Held in San Diego, California on April 24-26, 2007. Volume 4: Thursday Presentations

    DTIC Science & Technology

    2007-04-26

    Marc Gietter (#4929) Fuel reduction solutions for deployment of mobile electric power systems - Oerlikon Contraves , Philippe Bisaillon Eng. MEM...9,675 Whr/kg Global Commodity 8 e50 • 50 Watt Continuous Power • 12V • 100 Watt peak power • System Specifications • Dry system weight , less than 2.25...System Dry Weight 2.25kg Volume 4.5 Net System Efficiency 17% Specifications Specific Energy 3 Day Mission W-hr/kg 775 10 Day Mission W-hr/kg 1200 Goal

  16. A Water Vapor Differential Absorption LIDAR Design for Unpiloted Aerial Vehicles

    NASA Technical Reports Server (NTRS)

    DeYoung, Russell J.; Mead, Patricia F.

    2004-01-01

    This system study proposes the deployment of a water vapor Differential Absorption LIDAR (DIAL) system on an Altair unmanned aerial vehicle (UAV) platform. The Altair offers improved payload weight and volume performance, and longer total flight time as compared to other commercial UAV's. This study has generated a preliminary design for an Altair based water vapor DIAL system. The design includes a proposed DIAL schematic, a review of mechanical challenges such as temperature and humidity stresses on UAV deployed DIAL systems, an assessment of the available capacity for additional instrumentation (based on the proposed design), and an overview of possible weight and volume improvements associated with the use of customized electronic and computer hardware, and through the integration of advanced fiber-optic and laser products. The results of the study show that less than 17% of the available weight, less than 19% of the volume capacity, and approximately 11% of the electrical capacity is utilized by the proposed water vapor DIAL system on the Altair UAV.

  17. Near-Optimal Operation of Dual-Fuel Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Ardema, M. D.; Chou, H. C.; Bowles, J. V.

    1996-01-01

    A near-optimal guidance law for the ascent trajectory from earth surface to earth orbit of a fully reusable single-stage-to-orbit pure rocket launch vehicle is derived. Of interest are both the optimal operation of the propulsion system and the optimal flight path. A methodology is developed to investigate the optimal throttle switching of dual-fuel engines. The method is based on selecting propulsion system modes and parameters that maximize a certain performance function. This function is derived from consideration of the energy-state model of the aircraft equations of motion. Because the density of liquid hydrogen is relatively low, the sensitivity of perturbations in volume need to be taken into consideration as well as weight sensitivity. The cost functional is a weighted sum of fuel mass and volume; the weighting factor is chosen to minimize vehicle empty weight for a given payload mass and volume in orbit.

  18. Novel Liquid Sorbent C02 Removal System for Microgravity Applications

    NASA Technical Reports Server (NTRS)

    Rogers, Tanya; Westover, Shayne; Graf, John

    2017-01-01

    Removing Carbon Dioxide (CO2) from a spacecraft environment for deep space exploration requires a robust system that is low in weight, power, and volume. Current state-of-the-art microgravity compatible CO2 removal systems, such as the carbon dioxide removal assembly (CDRA), utilize solid sorbents that demand high power usage due to high desorption temperatures and a large volume to accommodate for their comparatively low capacity for CO2. Additionally, solid sorbent systems contain several mechanical components that significantly reduce reliability and contribute to a large overall mass. A liquid sorbent based system has been evaluated as an alternative is proposed to consume 65% less power, weight, and volume than solid based CO2 scrubbers. This paper presents the design of a liquid sorbent CO2 removal system for microgravity applications.

  19. The role of haptic versus visual volume cues in the size-weight illusion.

    PubMed

    Ellis, R R; Lederman, S J

    1993-03-01

    Three experiments establish the size-weight illusion as a primarily haptic phenomenon, despite its having been more traditionally considered an example of vision influencing haptic processing. Experiment 1 documents, across a broad range of stimulus weights and volumes, the existence of a purely haptic size-weight illusion, equal in strength to the traditional illusion. Experiment 2 demonstrates that haptic volume cues are both sufficient and necessary for a full-strength illusion. In contrast, visual volume cues are merely sufficient, and produce a relatively weaker effect. Experiment 3 establishes that congenitally blind subjects experience an effect as powerful as that of blindfolded sighted observers, thus demonstrating that visual imagery is also unnecessary for a robust size-weight illusion. The results are discussed in terms of their implications for both sensory and cognitive theories of the size-weight illusion. Applications of this work to a human factors design and to sensor-based systems for robotic manipulation are also briefly considered.

  20. Consequences of increasing convection onto patient care and protein removal in hemodialysis

    PubMed Central

    Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Le Quintrec, Moglie

    2017-01-01

    Introduction Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Methods Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. Results TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Conclusions Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin. PMID:28166268

  1. Consequences of increasing convection onto patient care and protein removal in hemodialysis.

    PubMed

    Gayrard, Nathalie; Ficheux, Alain; Duranton, Flore; Guzman, Caroline; Szwarc, Ilan; Vetromile, Fernando; Cazevieille, Chantal; Brunet, Philippe; Servel, Marie-Françoise; Argilés, Àngel; Le Quintrec, Moglie

    2017-01-01

    Recent randomised controlled trials suggest that on-line hemodiafiltration (OL-HDF) improves survival, provided that it reaches high convective volumes. However, there is scant information on the feasibility and the consequences of modifying convection volumes in clinics. Twelve stable dialysis patients were treated with high-flux 1.8 m2 polysulphone dialyzers and 4 levels of convection flows (QUF) based on GKD-UF monitoring of the system, for 1 week each. The consequences on dialysis delivery (transmembrane pressure (TMP), number of alarms, % of achieved prescribed convection) and efficacy (mass removal of low and high molecular weight compounds) were analysed. TMP increased exponentially with QUF (p<0.001 for N >56,000 monitoring values). Beyond 21 L/session, this resulted into frequent TMP alarms requiring nursing staff interventions (mean ± SEM: 10.3 ± 2.2 alarms per session, p<0.001 compared to lower convection volumes). Optimal convection volumes as assessed by GKD-UF-max were 20.6 ± 0.4 L/session, whilst 4 supplementary litres were obtained in the maximum situation (24.5 ± 0.6 L/session) but the proportion of sessions achieving the prescribed convection volume decreased from 94% to only 33% (p<0.001). Convection increased high molecular weight compound removal and shifted the membrane cut-off towards the higher molecular weight range. Reaching high convection volumes as recommended by the recent RCTs (> 20L) is feasible by setting an HDF system at its optimal conditions based upon the GKD-UF monitoring. Prescribing higher convection volumes resulted in instability of the system, provoked alarms, was bothersome for the nursing staff and the patients, rarely achieved the prescribed convection volumes and increased removal of high molecular weight compounds, notably albumin.

  2. Growth and Yield Predictions for Thinned Stands of Even-aged Natural Longleaf Pine

    Treesearch

    Robert M. Farrar

    1979-01-01

    This paper presents a system of equations and resulting tables that can predict stand volumes for thinned natural longleaf pine. The system can predict current and future total stand volume in cubic feet and merchantable stand volume in cubic feet, cords, and board feet. The system also provides for estimating dry-weight production of wood. The system uses input data...

  3. A Strategic Plan for the Crusader Howitzer

    DTIC Science & Technology

    2001-12-01

    of the system was its “volume under armor ,” which describes the actual size of the vehicle and hence its weight (DoD, December 2000, pg. 13). By...reducing the Crusader’s volume under armor , the designers would be able to dramatically reduce the system’s overall weight. This became one of the

  4. Volume dependent quasiparticle spectral weight in NiS2-xSex system

    NASA Astrophysics Data System (ADS)

    Marini, C.; Perucchi, A.; Dore, P.; Topwal, D.; Sarma, D. D.; Lupi, S.; Postorino, P.

    2012-05-01

    We discuss the evolution of Infrared reflectivity at room temperature under various pressures (P) and Se alloying concentration in the strongly correlated NiS2-xSex pyrite. Measurements gave a complete picture of the optical response of the system on approaching the P-induced and Se-induced metallic state. A peculiar non-monotonic (V-shaped) volume dependence was found for the quasiparticle spectral weight of both pure and Se-doped compounds.

  5. Improved scaling laws for stage inert mass of space propulsion systems. Volume 2: System modeling and weight data

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Technical models and analytical approaches used to develop the weight data for vehicle system concepts using advanced technology are reported. Weight data are supplied for the following major system elements: engine, pressurization, propellant containers, structural shells and secondary structure, and environmental protection shields for the meteoroid and thermal design requirements. Scaling laws, improved and a simplified set, are developed from the system weight data. The laws consider the implications of the major design parameters and mission requirements on the stage inert mass.

  6. Spatial feature analysis of a cosmic-ray sensor for measuring the soil water content: Comparison of four weighting methods

    NASA Astrophysics Data System (ADS)

    Cai, Jingya; Pang, Zhiguo; Fu, Jun'e.

    2018-04-01

    To quantitatively analyze the spatial features of a cosmic-ray sensor (CRS) (i.e., the measurement support volume of the CRS and the weight of the in situ point-scale soil water content (SWC) in terms of the regionally averaged SWC derived from the CRS) in measuring the SWC, cooperative observations based on CRS, oven drying and frequency domain reflectometry (FDR) methods are performed at the point and regional scales in a desert steppe area of the Inner Mongolia Autonomous Region. This region is flat with sparse vegetation cover consisting of only grass, thereby minimizing the effects of terrain and vegetation. Considering the two possibilities of the measurement support volume of the CRS, the results of four weighting methods are compared with the SWC monitored by FDR within an appropriate measurement support volume. The weighted average calculated using the neutron intensity-based weighting method (Ni weighting method) best fits the regionally averaged SWC measured by the CRS. Therefore, we conclude that the gyroscopic support volume and the weights determined by the Ni weighting method are the closest to the actual spatial features of the CRS when measuring the SWC. Based on these findings, a scale transformation model of the SWC from the point scale to the scale of the CRS measurement support volume is established. In addition, the spatial features simulated using the Ni weighting method are visualized by developing a software system.

  7. Crew appliance concepts. Volume 1, appendix A: Bibliography. [manned space shuttle orbiter environmental control and life support systems

    NASA Technical Reports Server (NTRS)

    Proctor, B. W.; Reysa, R. P.; Russell, D. J.

    1975-01-01

    A review of crew appliance related literature was made to provide background engineering information for development of conceptual appliance systems for the shuttle orbiter and the modular space station. From this review, a file containing abstracts of 299 appliance-related documents coded according to subject was developed along with a computerized bibliography of 682 references. Trade studies were conducted using information from these references to determine the optimum concepts to satisfy the shuttle and space station mission requirements. An appliance system was devised for each vehicle which has minimum impact to the respective environmental control system with the smallest possible weight, volume, and electrical penalty. Engineering parameters for each appliance concept considered are presented along with the total thermal and electrical loads and weight and volume penalties for each of the optimized appliance systems.

  8. Comparison of waste composition in a continuing-care retirement community.

    PubMed

    Kim, T; Shanklin, C W; Su, A Y; Hackes, B L; Ferris, D

    1997-04-01

    To determine the composition of wastes generated in a continuing-care retirement community (CCRC) and to analyze the effects of source-reduction activities and meal delivery system change on the amount of waste generated in the facility. A waste stream analysis was conducted at the same CCRC during spring 1994 (period 1: baseline), spring 1995 (period 2: source reduction intervention), and fall 1995 (period 3: service delivery intervention). Weight, volume, and collapsed volume were determined for food and packaging wastes. Tray service and wait staff service are provided to 70 residents in a health care unit, and family-style service is an optional service available to 130 residents in the independent-living units. A mean of 229 meals are served per day. Intervention included the implementation of source-reduction activities and a change in a service-delivery system in periods 2 and 3, respectively. Descriptive statistics were used to determine the composition of waste. Analysis of variance and a multiple comparison method (least significant difference) were used to compare mean weight and volume of waste generated in period 1 with data collected during periods 2 and 3. Mean waste generated per meal by weight and volume ranged from 0.93 to 1.00 lb and 1.44 to 1.65 gal, respectively. Significantly less production waste by weight (0.18 lb/meal) and volume (0.12 gal/meal) was generated in period 2 than in period 1 (0.32 lb/meal and 0.16 gal/meal, respectively). Significantly less service waste by weight (0.31 lb/meal) and volume (0.05 gal/meal) was discarded in period 3 than in period 1 (0.37 lb/meal and 0.15 gal/meal, respectively). Significantly less total waste and plastic by weight was disposed of after the interventions. The study conclusions indicated that implementing source-reduction practices and changing the meal-delivery system affected the composition of waste generated. Knowledge of waste stream composition can help other foodservice professionals and consulting dietitians identify waste-reduction activities and recycling opportunities. The quantity and type of waste generated should be considered when operational decisions are made relative to market form of food, menu choices, service-delivery systems, and production forecast and controls.

  9. Biennial Guidance Test Symposium (15th) Held in Holloman Air Force Base, New Mexico on 24-26 September 1991. Volume 1

    DTIC Science & Technology

    1991-09-01

    for loss , damage, or injury resulting from manufacture or use for any purpose of any product, article, system, or material involving reliance upon any...technologies but fit within an envelope of 10 pounds total weight , 20 watus of power, 100 cubic inches of volume, and a DARPA initiated the GPS Guidance...smaller volume and9 M I " 9•r @ •) 100 9 70• too lower weight constraints should also expand the _________- -number of future vehicles for GOP use. The

  10. Optimal trajectories for hypersonic launch vehicles

    NASA Technical Reports Server (NTRS)

    Ardema, Mark D.; Bowles, Jeffrey V.; Whittaker, Thomas

    1992-01-01

    In this paper, we derive a near-optimal guidance law for the ascent trajectory from Earth surface to Earth orbit of a hypersonic, dual-mode propulsion, lifting vehicle. Of interest are both the optimal flight path and the optimal operation of the propulsion system. The guidance law is developed from the energy-state approximation of the equations of motion. The performance objective is a weighted sum of fuel mass and volume, with the weighting factor selected to give minimum gross take-off weight for a specific payload mass and volume.

  11. Construction of a Chemical Sensor/Instrumentation Package Using Fiber Optic and Miniaturization Technology

    NASA Technical Reports Server (NTRS)

    Newton, R. L.

    1999-01-01

    The objective of this research was to construct a chemical sensor/instrumentation package that was smaller in weight and volume than conventional instrumentation. This reduction in weight and volume is needed to assist in further reducing the cost of launching payloads into space. To accomplish this, fiber optic sensors, miniaturized spectrometers, and wireless modems were employed. The system was evaluated using iodine as a calibration analyte.

  12. Volume comparison of radiofrequency ablation at 3- and 5-cm target volumes for four different radiofrequency generators: MR volumetry in an open 1-T MRI system versus macroscopic measurement.

    PubMed

    Rathke, Hendrik; Hamm, Bernd; Guettler, Felix; Lohneis, Philipp; Stroux, Andrea; Suttmeyer, Britta; Jonczyk, Martin; Teichgräber, Ulf; de Bucourt, Maximilian

    2015-12-01

    In a patient, it is usually not macroscopically possible to estimate the non-viable volume induced by radiofrequency ablation (RFA) after the procedure. The purpose of this study was to use an ex vivo bovine liver model to perform magnetic resonance (MR) volumetry of the visible tissue signal change induced by RFA and to correlate the MR measurement with the actual macroscopic volume measured in the dissected specimens. Sixty-four liver specimens cut from 16 bovine livers were ablated under constant simulated, close physiological conditions with target volumes set to 14.14 ml (3-cm lesion) and 65.45 ml (5-cm lesion). Four commercially available radiofrequency (RF) systems were tested (n=16 for each system; n=8 for 3 cm and n=8 for 5 cm). A T1-weighted turbo spin echo (TSE) sequence with inversion recovery and a proton-density (PD)-weighted TSE sequence were acquired in a 1.0-T open magnetic resonance imaging (MRI) system. After manual dissection, actual macroscopic ablation diameters were measured and volumes calculated. MR volumetry was performed using a semiautomatic software tool. To validate the correctness and feasibility of the volume formula in macroscopic measurements, MR multiplanar reformation diameter measurements with subsequent volume calculation and semiautomatic MR volumes were correlated. Semiautomatic MR volumetry yielded smaller volumes than manual measurement after dissection, irrespective of RF system used, target lesion size, and MR sequence. For the 3-cm lesion, only 43.3% (T1) and 41.5% (PD) of the entire necrosis are detectable. For the 5-cm lesion, only 40.8% (T1) and 37.2% (PD) are visualized in MRI directly after intervention. The correlation between semiautomatic MR volumes and calculated MR volumes was 0.888 for the T1-weighted sequence and 0.875 for the PD sequence. After correlation of semiautomatic MR volumes and calculated MR volumes, it seems reasonable to use the respective volume formula for macroscopic volume calculation. Hyperacute MRI after ex vivo intervention may result in the underestimation of the real expansion of the produced necrosis zone. This must be kept in mind when using MRI for validating ablation success directly after RFA. One reason for the discrepancy between macroscopic and MRI appearance immediately after RFA may be that the transitional zone shows no or only partially visible MR signal change.

  13. System and method of forming nanostructured ferritic alloy

    DOEpatents

    Dial, Laura Cerully; DiDomizio, Richard; Alinger, Matthew Joseph; Huang, Shenyan

    2016-07-26

    A system for mechanical milling and a method of mechanical milling are disclosed. The system includes a container, a feedstock, and milling media. The container encloses a processing volume. The feedstock and the milling media are disposed in the processing volume of the container. The feedstock includes metal or alloy powder and a ceramic compound. The feedstock is mechanically milled in the processing volume using metallic milling media that includes a surface portion that has a carbon content less than about 0.4 weight percent.

  14. Satellite voice broadcast. Volume 2: System study

    NASA Technical Reports Server (NTRS)

    Bachtell, E. E.; Bettadapur, S. S.; Coyner, J. V.; Farrell, C. E.

    1985-01-01

    The Technical Volume of the Satellite Broadcast System Study is presented. Designs are synthesized for direct sound broadcast satellite systems for HF-, VHF-, L-, and Ku-bands. Methods are developed and used to predict satellite weight, volume, and RF performance for the various concepts considered. Cost and schedule risk assessments are performed to predict time and cost required to implement selected concepts. Technology assessments and tradeoffs are made to identify critical enabling technologies that require development to bring technical risk to acceptable levels for full scale development.

  15. Fully automated system for the quantification of human osteoarthritic knee joint effusion volume using magnetic resonance imaging.

    PubMed

    Li, Wei; Abram, François; Pelletier, Jean-Pierre; Raynauld, Jean-Pierre; Dorais, Marc; d'Anjou, Marc-André; Martel-Pelletier, Johanne

    2010-01-01

    Joint effusion is frequently associated with osteoarthritis (OA) flare-up and is an important marker of therapeutic response. This study aimed at developing and validating a fully automated system based on magnetic resonance imaging (MRI) for the quantification of joint effusion volume in knee OA patients. MRI examinations consisted of two axial sequences: a T2-weighted true fast imaging with steady-state precession and a T1-weighted gradient echo. An automated joint effusion volume quantification system using MRI was developed and validated (a) with calibrated phantoms (cylinder and sphere) and effusion from knee OA patients; (b) with assessment by manual quantification; and (c) by direct aspiration. Twenty-five knee OA patients with joint effusion were included in the study. The automated joint effusion volume quantification was developed as a four stage sequencing process: bone segmentation, filtering of unrelated structures, segmentation of joint effusion, and subvoxel volume calculation. Validation experiments revealed excellent coefficients of variation with the calibrated cylinder (1.4%) and sphere (0.8%) phantoms. Comparison of the OA knee joint effusion volume assessed by the developed automated system and by manual quantification was also excellent (r = 0.98; P < 0.0001), as was the comparison with direct aspiration (r = 0.88; P = 0.0008). The newly developed fully automated MRI-based system provided precise quantification of OA knee joint effusion volume with excellent correlation with data from phantoms, a manual system, and joint aspiration. Such an automated system will be instrumental in improving the reproducibility/reliability of the evaluation of this marker in clinical application.

  16. Weight and volume equations and tables for red maple in the Lake States.

    Treesearch

    Thomas R. Crow; G.G. Erdmann

    1983-01-01

    Weight and volume information based on regional sampling are provided for red maple in the Lake States. Both green weight and dry weight values are presented for biomass. Volume equations predict total stem volume, volume to 8-inch top, and volume to 4-inch top, inside and outside bark.

  17. Standard operating procedures for standardized mass rearing of the dengue and chikungunya vectors Aedes aegypti and Aedes albopictus (Diptera: Culicidae) - I - egg quantification.

    PubMed

    Zheng, Min-Lin; Zhang, Dong-Jing; Damiens, David D; Yamada, Hanano; Gilles, Jeremie R L

    2015-01-23

    Quantification of eggs prior to rearing the immature stages of mosquitoes is an essential step in establishing a standardized mass rearing system. To develop a simple and accurate method of egg quantification for Aedes aegypti and Aedes albopictus, the relationship between egg number and weight, as well as egg number and volume, were studied. Known quantities of eggs (1,000, 3,000, 6,000, 12,000, 15,000, 18,000, 21,000 and 27,000) were counted and subsequently their weight and volume were measured. Best-fit curves and regression equations were used to describe relationships between Aedes egg number and both weight and volume. Eighteen thousand Ae. aegypti eggs weighed 159.8 mg and had a volume of 277.4 μl, compared to measurements of 131.5 mg and 230.3 μl for Ae. albopictus. The eggs of Ae. aegypti were thus larger and heavier than those of Ae. albopictus. The use of weight and volume to quantify egg number was validated by counting volumes and weights of eggs expected to correspond to 3,000 and 18,000 eggs of each species; significant correlations were found in all cases except in the case of 3,000 Ae. albopictus eggs measured by volume. Methods for egg quantification were validated and shown to be a consistent and practical means to achieve uniform distribution of Aedes larvae between rearing trays, important for optimal mass rearing of the immature stages of Aedes mosquitoes.

  18. Distributed Control Architecture for Gas Turbine Engine. Chapter 4

    NASA Technical Reports Server (NTRS)

    Culley, Dennis; Garg, Sanjay

    2009-01-01

    The transformation of engine control systems from centralized to distributed architecture is both necessary and enabling for future aeropropulsion applications. The continued growth of adaptive control applications and the trend to smaller, light weight cores is a counter influence on the weight and volume of control system hardware. A distributed engine control system using high temperature electronics and open systems communications will reverse the growing trend of control system weight ratio to total engine weight and also be a major factor in decreasing overall cost of ownership for aeropropulsion systems. The implementation of distributed engine control is not without significant challenges. There are the needs for high temperature electronics, development of simple, robust communications, and power supply for the on-board electronics.

  19. Fully automated system for the quantification of human osteoarthritic knee joint effusion volume using magnetic resonance imaging

    PubMed Central

    2010-01-01

    Introduction Joint effusion is frequently associated with osteoarthritis (OA) flare-up and is an important marker of therapeutic response. This study aimed at developing and validating a fully automated system based on magnetic resonance imaging (MRI) for the quantification of joint effusion volume in knee OA patients. Methods MRI examinations consisted of two axial sequences: a T2-weighted true fast imaging with steady-state precession and a T1-weighted gradient echo. An automated joint effusion volume quantification system using MRI was developed and validated (a) with calibrated phantoms (cylinder and sphere) and effusion from knee OA patients; (b) with assessment by manual quantification; and (c) by direct aspiration. Twenty-five knee OA patients with joint effusion were included in the study. Results The automated joint effusion volume quantification was developed as a four stage sequencing process: bone segmentation, filtering of unrelated structures, segmentation of joint effusion, and subvoxel volume calculation. Validation experiments revealed excellent coefficients of variation with the calibrated cylinder (1.4%) and sphere (0.8%) phantoms. Comparison of the OA knee joint effusion volume assessed by the developed automated system and by manual quantification was also excellent (r = 0.98; P < 0.0001), as was the comparison with direct aspiration (r = 0.88; P = 0.0008). Conclusions The newly developed fully automated MRI-based system provided precise quantification of OA knee joint effusion volume with excellent correlation with data from phantoms, a manual system, and joint aspiration. Such an automated system will be instrumental in improving the reproducibility/reliability of the evaluation of this marker in clinical application. PMID:20846392

  20. Space shuttle/food system study. Volume 1: Technical volume, oven study

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The baseline space shuttle galley was designed to utilize lightweight rehydratable foods, to be prepared for consumption by rehydration with chilled or hot water. The impact is examined of an extension of food types to include thermostabilized food, at ambient temperature, and frozen foods on the baseline design of the shuttle galley. Weight, volume, and power penalities associated with heating thermostabilized and frozen foods by means of a hot air convection heating system and a conduction heating system are determined along with the impact on crew/galley interface and meal preparation.

  1. THE ABSCOPAL EFFECT OF X IRRADIATION ON BONE GROWTH IN RATS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pappas, A.M.; Cohen, J.

    1963-06-01

    The abscopal effect of irradiation (that which is evident at a distance from the irradiated volume but within the same organism) was investigated in rats. It was possible to demonstrate the effects on growth locally and abscopally when x-ray doses of 400 and 800 r were delivered to the lower extremity and when 800 r was delivered to the knee alone. A distinction between abscopal effects after local irradiation and systemic effects after whole-body irradiation is discussed. The weights of control and irradiated animals were similar for the first 21 days, during which period they did not exhibit any untowardmore » effects of irradiation. However, after 21 days there was a decrease in weight gain, which persisted until the 72nd day. Group A (controls) was the heaviest group, with a mean weight of 412 g. Group B (800 r to the left hind extremity) had a mean weight of 378. Group C (400 r to the left hind extremity) and Group D (800 r to the left knee) exhibited mean weights of 391 and 394 g, respectively. Roentgenographic measurements revealed that all animals receiving irradiation had retardation in the growth of the irradiated tibiae, which were shorter than both the control and the contralateral (unirradiated) tibiae. Only the animals that had received 800 r to their leff hind extremity showed significant differences in the lengths of their unirradiated bones compared with the bones of the control animals of Group A, that is, a significant abscopal growth retardation. Although the abscopal effect appeared to be associated with the volume of tissue irradiated, the way this effect is mediated is not known. The weight gains of the animals demonstrated a strong association between decrease in weight gain, the volume of tissue irradiated, and the dose administered. The impaired weight gsin roughly paralleled the abscopal retardation of bone growth. The animals which received the highest dose of irradiation, 800 r, to the largest volume of tissue, 10% of the body volume, revealed the greatest deviation from the control group. It is concluded that irradiation effects in animals are composites of the responses of the whole organism to the injury, of the responses of local tissues, and vessels at their level of tissue organization, and of the responses of individual cells. All of these responses may be interdependent. The evidence indicates that a systemic inhibition of all bone growth and weight gain occurs when a sufficient volume of tissue is irradiated at a sufficiently high dosage. (BBB)« less

  2. Development of a weight/sizing design synthesis computer program. Volume 1: Program formulation

    NASA Technical Reports Server (NTRS)

    Garrison, J. M.

    1973-01-01

    The development of a weight/sizing design synthesis methodology for use in support of the main line space shuttle program is discussed. The methodology has a minimum number of data inputs and quick turn around capabilities. The methodology makes it possible to: (1) make weight comparisons between current shuttle configurations and proposed changes, (2) determine the effects of various subsystems trades on total systems weight, and (3) determine the effects of weight on performance and performance on weight.

  3. Multivariate Analysis, Retrieval, and Storage System (MARS). Volume 1: MARS System and Analysis Techniques

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Vanderberg, J. D.; Woodbury, N. W.

    1974-01-01

    A method for rapidly examining the probable applicability of weight estimating formulae to a specific aerospace vehicle design is presented. The Multivariate Analysis Retrieval and Storage System (MARS) is comprised of three computer programs which sequentially operate on the weight and geometry characteristics of past aerospace vehicles designs. Weight and geometric characteristics are stored in a set of data bases which are fully computerized. Additional data bases are readily added to the MARS system and/or the existing data bases may be easily expanded to include additional vehicles or vehicle characteristics.

  4. GASP- General Aviation Synthesis Program. Volume 5: Weight

    NASA Technical Reports Server (NTRS)

    Hague, D.

    1978-01-01

    Subroutines for determining the weights of propulsion system related components and the airframe components of an aircraft configuration are presented. Subroutines that deal with design load conditions, aircraft balance, and tail sizing are included. Options for turbine and internal combustion engines are provided.

  5. Space shuttle/food system study. Volume 2, Appendix F: Flight food and primary packaging

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The analysis and selection of food items and primary packaging, the development of menus, the nutritional analysis of diet, and the analyses of alternate food mixes and contingency foods is reported in terms of the overall food system design for space shuttle flight. Stowage weights and cubic volumes associated with each alternate mix were also evaluated.

  6. Use of recycling stations in Borlänge, Sweden--volume weights and attitudes.

    PubMed

    Petersen, Cecilia H Mattsson; Berg, Per E O

    2004-01-01

    This paper presents a study of recycling stations in the municipality of Borlänge, Sweden. The main objectives were to measure volume weights of recyclables, to facilitate future planning of collection intervals and bin/container volume, and to investigate the general attitudes among the public towards waste management in general and recycling stations in particular. Volume weights measured in bins/containers were: paper/newsprint: 297 kg/m3, glass packaging: 297 kg/m3, metal packaging: 81.7 kg/m3, paper packaging: 27.8 kg/m3, plastic packaging: 28.1 kg/m3. The recycling stations have been in use since 1994. Most visitors (90%) arrived by car but said the visit to the recycling station was not the main purpose of the trip. The results from the interviews indicated that the people who use the recycling stations have found ways to incorporate waste sorting into their everyday lives, with the help of information, design of the collection system and environmental concerns.

  7. A hybrid power system for unmanned aerial vehicle electromagnetic launcher

    NASA Astrophysics Data System (ADS)

    Wang, Zhiren; Wu, Jun; Huang, Shengjun

    2018-06-01

    According to the UAV electromagnetic catapult with fixed timing, a hybrid energy storage system consist with battery and super capacitor is designed, in order to reduce the volume and weight of the energy storage system. The battery is regarded as the energy storage device and the super capacitor as power release device. Firstly, the battery charges the super capacitor, and then the super capacitor supplies power to electromagnetic catapult separately. The strategy is using the Buck circuit to charge the super capacitor with constant current and using the Boost circuit to make super capacitor provide a stable voltage circuit for electromagnetic catapult. The Simulink simulation results show that the designed hybrid energy storage system can meet the requirements of electromagnetic catapult. Compared with the system powered by the battery alone, the proposed scheme can reduce the number of batteries, and greatly reduce the volume and weight of the energy storage system.

  8. Sixteenth ARPA Systems and Technology Symposium

    DTIC Science & Technology

    1993-06-22

    10:1 weight reduction over existing MILSTAR feed networks. 0 • In addition, EMS has demonstrated their dedication to ARPA and this technology bY cost...Corporation Computing Devices International DynCorp-Meridian COMSAT Laboratories E-Systems Inc. Context Systems Eastman Kodak Company Contraves Inc. EG&G CTA...were outstanding mathematicians and said, "Your first project is to compute how much volume and weight of water would fill the light bulb." He gave

  9. Rapid Cycling CO2 and H2O Removal System for EMU

    NASA Technical Reports Server (NTRS)

    Alptekin, Gokhan; Cates, Matthew; Dubovik, Margarita; Gershanovich, Yevgenia; Paul, Heather; Thomas, Gretchen

    2006-01-01

    NASA's planned future missions set stringent demands on the design of the Portable Life Support Systems (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the EMU is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The CO2 and humidity control unit in the existing PLSS design is relatively large, since it has to remove 8 hours worth of CO2. If the sorbent regeneration can be carried out during the extravehicular activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. TDA Research, Inc. (TDA) is developing a compact, regenerable sorbent-based system to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all duration-limiting elements in the life support system. This paper summarizes the results of the sorbent development and testing, and evaluation efforts. The results of a preliminary system analysis are also included, showing the size and volume reductions provided by the new system.

  10. Propulsion System Technology for Military Land Vehicles

    DTIC Science & Technology

    1981-08-01

    torques) to decrease specific weight and volume; and (3) hybrid transmissions using low-torque devices (electrical converters or traction drives) with a... VEICLE SPEC POMWE, bWtu FIGURE 1. Impact of vehicle specific power on weight and manufacturing cost of armored vehicles. 15 [ 𔃺!00, LCV .30 *1

  11. Estimation of standard liver volume in Chinese adult living donors.

    PubMed

    Fu-Gui, L; Lu-Nan, Y; Bo, L; Yong, Z; Tian-Fu, W; Ming-Qing, X; Wen-Tao, W; Zhe-Yu, C

    2009-12-01

    To determine a formula predicting the standard liver volume based on body surface area (BSA) or body weight in Chinese adults. A total of 115 consecutive right-lobe living donors not including the middle hepatic vein underwent right hemi-hepatectomy. No organs were used from prisoners, and no subjects were prisoners. Donor anthropometric data including age, gender, body weight, and body height were recorded prospectively. The weights and volumes of the right lobe liver grafts were measured at the back table. Liver weights and volumes were calculated from the right lobe graft weight and volume obtained at the back table, divided by the proportion of the right lobe on computed tomography. By simple linear regression analysis and stepwise multiple linear regression analysis, we correlated calculated liver volume and body height, body weight, or body surface area. The subjects had a mean age of 35.97 +/- 9.6 years, and a female-to-male ratio of 60:55. The mean volume of the right lobe was 727.47 +/- 136.17 mL, occupying 55.59% +/- 6.70% of the whole liver by computed tomography. The volume of the right lobe was 581.73 +/- 96.137 mL, and the estimated liver volume was 1053.08 +/- 167.56 mL. Females of the same body weight showed a slightly lower liver weight. By simple linear regression analysis and stepwise multiple linear regression analysis, a formula was derived based on body weight. All formulae except the Hong Kong formula overestimated liver volume compared to this formula. The formula of standard liver volume, SLV (mL) = 11.508 x body weight (kg) + 334.024, may be applied to estimate liver volumes in Chinese adults.

  12. Weight versus volume in breast surgery: an observational study

    PubMed Central

    Parmar, Chetan; West, Malcolm; Pathak, Samir; Nelson, J; Martin, Lee

    2011-01-01

    Objectives The study hypothesis is to assess correlation of breast specimen weight versus volume. Design Consecutive patients undergoing breast surgery at a single tertiary referral centre during a 6-month period were included. Specimen weight was measured in grams. Direct volume measurements were performed using water displacement. Data including side of the breast, age and menstrual status of the patient were noted. Setting Knowledge of breast volume provides an objective guide in facilitating the achievements of balance in reconstructive operations. Surgeons use intraoperative weight measurements from individual breasts to calculate the breast volume assuming that weight is equal to the volume of the specimen. However, it is unclear whether weight accurately reveals the true volume of resection. Participants Forty-one patients were included in the study with 28 having bilateral surgeries, 13 having unilateral procedures giving a total of 69 breast specimens. Main outcome measures Breast specimen weight correlation to breast specimen volume. Results The mean age of the group was 42.4 years. Fifty-two specimens were from premenopausal patients and 17 were of postmenopausal. Thirty-five were left-sided. Twenty-six patients had bilateral breast reduction, two had bilateral mastectomy, nine had a unilateral mastectomy and four patients had a unilateral breast reduction. The difference between weight and volume of these breasts was 36.4 units (6.6% difference). The difference in measurement of weight and volume in premenopausal was 37.6 units compared to 32.6 units in postmenopausal women. The density was 1.07 and 1.06, respectively. This was statistically not significant. Conclusions No significant difference between volume and weight was seen in this series. Furthermore, we are unable to support the notion that premenopausal patients have a significant difference in the proportion of fatty and glandular tissue as there was little difference between the weight and the volume. An easy, clinically proper formula for the quantification of actual breast volume has yet to be derived. PMID:22140613

  13. Weight versus volume in breast surgery: an observational study.

    PubMed

    Parmar, Chetan; West, Malcolm; Pathak, Samir; Nelson, J; Martin, Lee

    2011-11-01

    The study hypothesis is to assess correlation of breast specimen weight versus volume. Consecutive patients undergoing breast surgery at a single tertiary referral centre during a 6-month period were included. Specimen weight was measured in grams. Direct volume measurements were performed using water displacement. Data including side of the breast, age and menstrual status of the patient were noted. Knowledge of breast volume provides an objective guide in facilitating the achievements of balance in reconstructive operations. Surgeons use intraoperative weight measurements from individual breasts to calculate the breast volume assuming that weight is equal to the volume of the specimen. However, it is unclear whether weight accurately reveals the true volume of resection. Forty-one patients were included in the study with 28 having bilateral surgeries, 13 having unilateral procedures giving a total of 69 breast specimens. Breast specimen weight correlation to breast specimen volume. The mean age of the group was 42.4 years. Fifty-two specimens were from premenopausal patients and 17 were of postmenopausal. Thirty-five were left-sided. Twenty-six patients had bilateral breast reduction, two had bilateral mastectomy, nine had a unilateral mastectomy and four patients had a unilateral breast reduction. The difference between weight and volume of these breasts was 36.4 units (6.6% difference). The difference in measurement of weight and volume in premenopausal was 37.6 units compared to 32.6 units in postmenopausal women. The density was 1.07 and 1.06, respectively. This was statistically not significant. No significant difference between volume and weight was seen in this series. Furthermore, we are unable to support the notion that premenopausal patients have a significant difference in the proportion of fatty and glandular tissue as there was little difference between the weight and the volume. An easy, clinically proper formula for the quantification of actual breast volume has yet to be derived.

  14. Space shuttle/food system study. Volume 2, appendix E: Alternate flight systems analysis

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The functional requirements of stowage, preparation, serving, consumption, and cleanup were applied to each of the five food mixes selected for study in terms of the overall design of the space shuttle food system. The analysis led to a definition of performance requirements for each food mix, along with a definition of equipment to meet those requirements. Weight and volume data for all five systems, in terms of food and packaging, support equipment, and galley installation penalties, are presented.

  15. [Non-pharmacologic treatment of arterial hypertension in hemodialysis patients].

    PubMed

    Chazot, C; Charra, B

    2007-10-01

    High blood pressure in dialysis patients is related to extracellular volume excess and the related increase of systemic vascular resistances. Scribner has early described the treatment of hypertension with ultrafiltration and low salt diet, without any drugs. The dry weight method relies on the progressive reduction of the postdialysis body weight until blood pressure is normalized. Additional measures are needed such as low salt diet, neutral sodium balance during dialysis treatment, stop of antihypertensive drugs, adequate length of the dialysis session, and patient education. It may exist a lag time between the normalization of the extracellular volume and blood pressure. It is related to the correction of the hemodynamic consequences of the extracellular volume overload. Moreover, the dry weight may potentially vary in patients undergoing catabolic intercurrent events. The complications of these changes (severe hypertension, pulmonary oedema) must be anticipated by the nephrologist and the staff to avoid additional morbidity to the patient.

  16. PALS Free Volume Measurements of Fractionated Hydrido- Silsesquioxane Resin.

    NASA Astrophysics Data System (ADS)

    Madani, Mahmoud M.; Granata, Richard D.; Pernisz, Udo C.

    1997-03-01

    Hydrido-Silsesquioxane (HSQ) is a resinous polymer with monomer unit formula (HSiO_3/2)_n. For n=8...16, it forms cages which in turn cross-link to yield a resin with a broad molecular weight distribution. It is soluble and forms thin films that may be converted to low-density silica with excellent dielectric properties. These, and the HSQ solubility, depend on molecular structure and size distribution of the cages. Samples of different molecular weight fractions were prepared from HSQ by SCF and the free volume of several cuts was measured by PALS in a conventional fast-fast system. POSITRONFIT and CONTIN programs were used to analyze the spectra. Three separate lifetime regions were identified with free volume regimes that correlate strongly with the molecular weight. The lowest is identified with the monomer cage unit, the larger values with intramolecular separation.

  17. Advanced nickel-hydrogen cell configuration study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Long-term trends in the evolution of space power technology point toward increased payload power demand which in turn translates into both higher battery system charge storage capability and higher operating voltages. State of the art nickel-hydrogen cells of the 50 to 60 Wh size, packaged in individual pressure vessels, are capable of meeting the required cycle life for a wide range of anticipated operating conditions; however, they provided several drawbacks to battery system integrated efforts. Because of size, high voltage/high power systems require integrating hundreds of cells into the operating system. Packaging related weight and volume inefficiencies degrade the energy density and specific energy of individual cells currently at 30 Wh/cudm and 40 Wh/kg respectively. In addition, the increased parts count and associated handling significantly affect the overall battery related costs. Spacecraft battery systems designers within industry and Government realize that to reduce weight, volume, and cost requires increases in the capacity of nickel-hydrogen cells.

  18. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2015-09-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.

  19. Estimating aspen volume and weight for individual trees, diameter classes, or entire stands.

    Treesearch

    Bryce E. Schlaegel

    1975-01-01

    Presents allometric volume and weight equations for Minnesota quaking aspen. Volume, green weight, and dry weight estimates can be made for wood, bark, and limbs on the basis of individual trees, diameter classes, or entire stands.

  20. Technology requirements for future Earth-to-geosynchronous orbit transportation systems. Volume 3: Appendices

    NASA Technical Reports Server (NTRS)

    Caluori, V. A.; Conrad, R. T.; Jenkins, J. C.

    1980-01-01

    Technological requirements and forecasts of rocket engine parameters and launch vehicles for future Earth to geosynchronous orbit transportation systems are presented. The parametric performance, weight, and envelope data for the LOX/CH4, fuel cooled, staged combustion cycle and the hydrogen cooled, expander bleed cycle engine concepts are discussed. The costing methodology and ground rules used to develop the engine study are summarized. The weight estimating methodology for winged launched vehicles is described and summary data, used to evaluate and compare weight data for dedicated and integrated O2/H2 subsystems for the SSTO, HLLV and POTV are presented. Detail weights, comparisons, and weight scaling equations are provided.

  1. The significance of placental ratios in pregnancies complicated by small for gestational age, preeclampsia, and gestational diabetes mellitus.

    PubMed

    Kim, Hee Sun; Cho, Soo Hyun; Kwon, Han Sung; Sohn, In Sook; Hwang, Han Sung

    2014-09-01

    This study aimed to evaluate the placental weight, volume, and density, and investigate the significance of placental ratios in pregnancies complicated by small for gestational age (SGA), preeclampsia (PE), and gestational diabetes mellitus (GDM). Two hundred and fifty-four pregnant women were enrolled from August 2005 through July 2013. Participants were divided into four groups: control (n=82), SGA (n=37), PE (n=102), and GDM (n=33). The PE group was classified as PE without intrauterine growth restriction (n=65) and PE with intrauterine growth restriction (n=37). Birth weight, placental weight, placental volume, placental density, and placental ratios including birth weight/placental weight ratio (BPW) and birth weight/placental volume ratio (BPV) were compared between groups. Birth weight, placental weight, and placental volume were lower in the SGA group than in the control group. However, the BPW and BPV did not differ between the two groups. Birth weight, placental weight, placental volume, BPW, and BPV were all significantly lower in the PE group than in the control group. Compared with the control group, birth weight, BPW, and BPV were higher in the GDM group, whereas placental weight and volume did not differ in the two groups. Placental density was not significantly different among the four groups. Placental ratios based on placental weight, placental volume, placental density, and birth weight are helpful in understanding the pathophysiology of complicated pregnancies. Moreover, they can be used as predictors of pregnancy complications.

  2. Diurnal Changes in Volume and Specific Tissue Weight of Crassulacean Acid Metabolism Plants 1

    PubMed Central

    Chen, Sheng-Shu; Black, Clanton C.

    1983-01-01

    The diurnal variations in volume and in specific weight were determined for green stems and leaves of Crassulacen acid metabolism (CAM) plants. Volume changes were measured by a water displacement method. Diurnal variations occurred in the volume of green CAM tissues. Their volume increased early in the light period reaching a maximum about mid-day, then the volume decreased to a minimum near midnight. The maximum volume increase each day was about 2.7% of the total volume. Control leaves of C3 and C4 plants exhibited reverse diurnal volume changes of 0.2 to 0.4%. The hypothesis is presented and supported that green CAM tissues should exhibit a diurnal increase in volume due to the increase of internal gas pressure from CO2 and O2 when their stomata are closed. Conversely, the volume should decrease when the gas pressure is decreased. The second hypothesis presented and supported was that the specific weight (milligrams of dry weight per square centimeter of green surface area) of green CAM tissues should increase at night due to the net fixation of CO2. Green CAM tissues increased their specific weight at night in contrast to control C3 and C4 leaves which decreased their specific weight at night. With Kalanchoë daigremontiana leaves, the calculated increase in specific leaf weight at night based on estimates of carbohydrate available for net CO2 fixation was near 6% and the measured increase in specific leaf weight was 6%. Diurnal measurements of CAM tissue water content were neither coincident nor reciprocal with their diurnal patterns of either volume or specific weight changes. PMID:16662833

  3. Early post-operative weight loss after laparoscopic sleeve gastrectomy correlates with the volume of the excised stomach and not with that of the sleeve! Preliminary data from a multi-detector computed tomography-based study.

    PubMed

    Pawanindra, Lal; Vindal, Anubhav; Midha, Manoj; Nagpal, Prashant; Manchanda, Alpana; Chander, Jagdish

    2015-10-01

    Pre- and post-operative stomach volumes can be important determinants for effectiveness of laparoscopic sleeve gastrectomy (LSG) in causing weight loss. There is little existing data on the volumes of stomach preoperatively and that excised during LSG. This study was designed to evaluate the change in gastric volume after LSG using multi-detector CT and to correlate it with early post-operative weight loss. Twenty consecutive patients with BMI ≥ 40 kg/m(2) and medical comorbidities underwent LSG between October 2011 and October 2013 and were analysed prospectively. The pre-operative stomach volume was measured by MDCT done 1-3 days before the surgery. LSG was performed in the standard manner using a 36F bougie. The volume of excised stomach was measured by distending the specimen with saline. MDCT of the upper abdomen was repeated 3 months postoperatively to calculate the gastric sleeve volume. Weight loss and resolution of comorbidities were documented. The mean pre-operative weight of patients was 123.90 kg, and the mean pre-operative stomach volume on MDCT was 1,067 ml. The stomach volume on pre-operative MDCT correlated with pre-operative weight and BMI. The mean volume of the excised stomach was 859 ml when measured by distension of the specimen and 850 ml on MDCT. After 3 months post surgery, the mean volume of gastric sleeve on MDCT was 217 ml, and the mean weight of the patients was 101.22 kg. The volume of the excised stomach calculated by MDCT correlated with the weight loss achieved 3 months postoperatively. However, no correlation was seen between the gastric sleeve volume 3 months postoperatively and weight loss during this period. MDCT is a good method to measure gastric volume before and after LSG. Early post-operative weight loss (3 months) correlates well with the volume of the excised stomach but not with that of the gastric sleeve.

  4. MRI Features in a Canine Model of Ischemic Stroke: Correlation between Lesion Volume and Neurobehavioral Status during the Subacute Stage

    PubMed Central

    Kang, Byeong-Teck; Jang, Dong-Pyo; Gu, Su-Hyun; Lee, Jong-Hwan; Jung, Dong-In; Lim, Chae-Young; Kim, Ha-Jung; Kim, Young-Bo; Kim, Hyung-Joong; Woo, Eung-Je; Cho, Zang-Hee; Park, Hee-Myung

    2009-01-01

    The purpose of this study was to evaluate the diagnostic value of magnetic resonance imaging (MRI) and assess the correlation between the volume of the ischemic lesion and neurobehavioral status during the subacute stage of ischemic stroke. Ischemic stroke was induced in 6 healthy laboratory beagles through permanent occlusion of the middle cerebral artery (MCAO). T2-weighted and fluid-attenuated inversion recovery (FLAIR) imaging, diffusion-weighted imaging (DWI), measurement of the apparent diffusion coefficient (ADC) ratio, and neurobehavioral evaluation were performed 3 times serially by using a 1.5-T MR system: before and 3 and 10 d after MCAO. Ischemic lesions demonstrated T2 hyperintensity, FLAIR hyperintensity, and DWI hyperintensity. The ADC ratio was decreased initially but then was increased at 10 d after MCAO. Ischemic lesion volumes on T2-weighted and FLAIR imaging were not significantly different from those on DWI. The lesion volume and neurobehavioral score showed strong correlation. Our results suggest that conventional MRI may be a reliable diagnostic tool during the subacute stage of canine ischemic stroke. PMID:19887030

  5. Optimal Sensor Allocation for Fault Detection and Isolation

    NASA Technical Reports Server (NTRS)

    Azam, Mohammad; Pattipati, Krishna; Patterson-Hine, Ann

    2004-01-01

    Automatic fault diagnostic schemes rely on various types of sensors (e.g., temperature, pressure, vibration, etc) to measure the system parameters. Efficacy of a diagnostic scheme is largely dependent on the amount and quality of information available from these sensors. The reliability of sensors, as well as the weight, volume, power, and cost constraints, often makes it impractical to monitor a large number of system parameters. An optimized sensor allocation that maximizes the fault diagnosibility, subject to specified weight, volume, power, and cost constraints is required. Use of optimal sensor allocation strategies during the design phase can ensure better diagnostics at a reduced cost for a system incorporating a high degree of built-in testing. In this paper, we propose an approach that employs multiple fault diagnosis (MFD) and optimization techniques for optimal sensor placement for fault detection and isolation (FDI) in complex systems. Keywords: sensor allocation, multiple fault diagnosis, Lagrangian relaxation, approximate belief revision, multidimensional knapsack problem.

  6. NATO Standardization and Licensing Policy-Exploratory Phase. Volume 3. Supplement

    DTIC Science & Technology

    1976-11-30

    Aerospatiale will perform at least half the production of this aircraft.* The concept involves a relatively light- weight advanced interceptor with...a ratio of total thrust to takeoff gross weight of about unity. The technology of the aircraft calls for the use of carbon fiber in selected...presenting a system with operating temperatures, pressure ratios, and thrust-to- weight ratios roughly comparable to U.S. technology. The

  7. Sandblasting and silica coating of a glass-infiltrated alumina ceramic: volume loss, morphology, and changes in the surface composition.

    PubMed

    Kern, M; Thompson, V P

    1994-05-01

    Silica coating can improve bonding of resin to glass-infiltrated aluminum oxide ceramic (In-Ceram), and sandblasting is a pretreatment to thermal silica coating (Silicoater MD system) or a tribochemical coating process (Rocatec system). This study evaluated the effects of sandblasting and coating techniques on volume loss, surface morphology, and surface composition of In-Ceram ceramic. Volume loss through sandblasting was 36 times less for In-Ceram ceramic compared with a feldspathic glass ceramic (IPS-Empress), and sandblasting of In-Ceram ceramic did not change its surface composition. After tribochemical coating with the Rocatec system, a layer of small silica particles remained that elevated the silica content to 19.7 weight percentage (energy-dispersive spectroscopy). Ultrasonic cleaning removed loose silica particles from the surface and decreased the silica content to 15.8 weight percentage, which suggested firm attachment of most of the silica layer to the surface. After treatment with the Silicoater MD system, the silica content increased only slightly from that of the sandblasted specimen. The silica layer created by these systems differs greatly in both morphology and thickness, which could result in different bond strengths. Sandblasting of all ceramic clinical restorations with feldspathic glass materials should be avoided, but for In-Ceram ceramic the volume loss was within an acceptable range and similar to that of noble metals.

  8. Buying pulpwood by weight as compared with volume measure

    Treesearch

    Michael A. Taras

    1956-01-01

    During the past few years several pulp and paper companies in the Southeast have started to purchase pulpwood by weight rather thanby volume. The trend toward buying by weight is strong and getting stronger. This conversion from volume to weight measurement of pulpwood brings up many questions. For instance, is the weight basis fair to both buyer and seller? What are...

  9. Experimental determination and allometric prediction of vitreous volume, and retina and lens weights in Göttingen minipigs.

    PubMed

    Shafiee, Afshin; McIntire, Greg L; Sidebotham, Lisa C; Ward, Keith W

    2008-01-01

    To determine the vitreous volume, and retinal and lens wet weights in male and female Göttingen minipigs of different age groups. Vitreous, lens and retina were isolated from fresh minipig eyes. Vitreous volume, lens and retina weight were measured and allometric scaling was utilized to predict these parameters. There were no gender differences in body weights or retina and lens weights in the three age groups examined in this study. For vitreous volumes, females had a significantly larger volume (approximately 10%-12%) than males in the 4-6 and 6-8 month, but not in the 8-11-month group. The mean body weight increased from 12.2 +/- 2.6 kg (4-6 months) to 19.4 +/- 4.0 kg (8-11 months). In the same period, the mean vitreous volume increased from 2.00 +/- 0.28 to 2.67 +/- 0.31 mL, while the mean retinal and lens weights increased from 114 +/- 22 to 126 +/- 17 mg, and from 298 +/- 26 to 392 +/- 15 mg, respectively. Allometric analysis between six species for vitreous volume and four species for lens weight covering a weight range of 260-fold was not able to estimate the vitreous volume, but it did predict the lens weight in 8-11 months minipigs. Overall these measurements add important context to intraocular pharmacology studies, and will help in the improved design and interpretation of such experiments.

  10. Tray service generates more food waste in dining areas of a continuing-care retirement community.

    PubMed

    Hackes, B L; Shanklin, C W; Kim, T; Su, A Y

    1997-08-01

    To determine if the type of service system affects the amount of service food waste (SFW) generated in dining areas of a continuing-care retirement community. A waste stream analysis was conducted for 7 days to determine quantity of SFW generated in three service systems: health care tray service, health care dining room with wait-staff service, and ambulatory dining room with family-style service. Weight and volume were determined. Health care tray service and wait-staff service were provided to 70 residents in a health care unit. Family-style service was provided as an optional service for 130 residents in independent-living units. An average of 229 meals were served per day. Analysis of variance and a multiple comparison method were used to compare mean weight and volume of SFW on a per meal, per day, and per week basis. During the 7-day period, 482.8 lb, or 83 gal, of SFW was disposed of Health care tray service generated more SFW by weight for all three meals than either family-style service or wait-staff service, and it generated the greatest total volume of service waste. Residents eating in the dining room with family-style service disposed of significantly less SFW by weight at lunch and dinner than those receiving the other two service styles. Changing the style of service can affect not only quantity of solid waste generated and associated disposal costs but also food and supply costs, meal acceptability, and quantity of natural resources required. The systems approach should be used to assess the feasibility of changing service system so that all costs are considered.

  11. Multivariate Analysis, Retrieval, and Storage System (MARS). Volume 6: MARS System - A Sample Problem (Gross Weight of Subsonic Transports)

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Woodbury, N. W.

    1975-01-01

    The Mars system is a tool for rapid prediction of aircraft or engine characteristics based on correlation-regression analysis of past designs stored in the data bases. An example of output obtained from the MARS system, which involves derivation of an expression for gross weight of subsonic transport aircraft in terms of nine independent variables is given. The need is illustrated for careful selection of correlation variables and for continual review of the resulting estimation equations. For Vol. 1, see N76-10089.

  12. Low midpregnancy placental volume in rural Indian women: A cause for low birth weight?

    PubMed

    Kinare, A S; Natekar, A S; Chinchwadkar, M C; Yajnik, C S; Coyaji, K J; Fall, C H; Howe, D T

    2000-02-01

    We sought to study midpregnancy placental volume in rural Indian women, its maternal determinants, and its relationship to neonatal size. We performed a prospective community-based study of maternal nutrition and fetal growth in 6 villages near the city of Pune. Measurements included midpregnancy placental volume determined by means of ultrasonography at 15 to 18 weeks' gestation, maternal anthropometric measurements before and during pregnancy, and maternal blood pressure and biochemical parameters during pregnancy. Neonatal size and placental weight were measured at birth. The mothers were short and underweight (mean height, 1.52 m; weight, 42 kg; body mass index, 18 kg/m(2)) and produced small babies (mean birth weight, 2648 g). Midpregnancy placental volume (median, 144 mL) was related to the mother's prepregnancy weight (r = 0.15; P <.001) but not to weight gain during pregnancy, blood pressure, or circulating hemoglobin, ferritin, red blood cell folate, or glucose concentrations. Midpregnancy placental volume was related to placental weight at birth (r = 0.29; P <.001) and birth weight (r = 0.25; P <.001) independent of maternal size. In Indian mothers midpregnancy placental volume is significantly associated with prepregnant maternal weight and is an independent predictor of birth weight. Our findings may provide clues to the high prevalence of low-birth-weight infants in India.

  13. The adjusting factor method for weight-scaling truckloads of mixed hardwood sawlogs

    Treesearch

    Edward L. Adams

    1976-01-01

    A new method of weight-scaling truckloads of mixed hardwood sawlogs systematically adjusts for changes in the weight/volume ratio of logs coming into a sawmill. It uses a conversion factor based on the running average of weight/volume ratios of randomly selected sample loads. A test of the method indicated that over a period of time the weight-scaled volume should...

  14. Pancreas segmentation from 3D abdominal CT images using patient-specific weighted subspatial probabilistic atlases

    NASA Astrophysics Data System (ADS)

    Karasawa, Kenichi; Oda, Masahiro; Hayashi, Yuichiro; Nimura, Yukitaka; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Rueckert, Daniel; Mori, Kensaku

    2015-03-01

    Abdominal organ segmentations from CT volumes are now widely used in the computer-aided diagnosis and surgery assistance systems. Among abdominal organs, the pancreas is especially difficult to segment because of its large individual differences of the shape and position. In this paper, we propose a new pancreas segmentation method from 3D abdominal CT volumes using patient-specific weighted-subspatial probabilistic atlases. First of all, we perform normalization of organ shapes in training volumes and an input volume. We extract the Volume Of Interest (VOI) of the pancreas from the training volumes and an input volume. We divide each training VOI and input VOI into some cubic regions. We use a nonrigid registration method to register these cubic regions of the training VOI to corresponding regions of the input VOI. Based on the registration results, we calculate similarities between each cubic region of the training VOI and corresponding region of the input VOI. We select cubic regions of training volumes having the top N similarities in each cubic region. We subspatially construct probabilistic atlases weighted by the similarities in each cubic region. After integrating these probabilistic atlases in cubic regions into one, we perform a rough-to-precise segmentation of the pancreas using the atlas. The results of the experiments showed that utilization of the training volumes having the top N similarities in each cubic region led good results of the pancreas segmentation. The Jaccard Index and the average surface distance of the result were 58.9% and 2.04mm on average, respectively.

  15. Nuttall Oak Volume and Weight Tables

    Treesearch

    Bryce E. Schlaegel; Regan B. Willson

    1983-01-01

    Volume and weight tables were constructed from a 62-tree sample of Nuttall oak (Quercus nuttallii Palmer) taken in the Mississippi Delta. The tables present volume, green weight, and dry weight of bole wood, bole wood plus bark, and total tree above a one-foot stump as predicted from the nonlinear model Y = 0Db

  16. Weight Measurement and Volumetric Displacement of Breast Implants and Tissue Expanders: Why Port and Shell Volumes Matter in Breast Reconstruction, Augmentation, and Revision.

    PubMed

    Wenzel, Chad G; Wacholtz, William F; Janssen, David A; Bengtson, Bradley P

    2015-10-01

    There are significant differences in weight and volumetric characteristics between silicone and saline breast implants of which most plastic surgeons are unaware. Phase I of this study was a weight measurement focused on recording differences in the weight of saline volumes instilled versus recorded weights of saline implants and expanders. Phase II compared displaced volume differences of tissue expanders with instilled volumes. As a result of this study, surgeons should now be able to precisely calculate the volume created for breast pocket development, allowing for accurate matching of expander and final breast implant. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Teleoperator Maneuvering System (TMS) benefits assessment study. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Teleoperator Maneuvering System (TMS) versus integral spacecraft propulsion, spacecraft maintenance, cost benefits, launch prices, integral propulsion length penalties, remote maintenance versus EVA, potential weight reduction benefits, basing mode, mission models and payload requirements, and program profitability are discussed.

  18. Space shuttle/food system. Volume 2, Appendix C: Food cooling techniques analysis. Appendix D: Package and stowage: Alternate concepts analysis

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The relative penalties associated with various techniques for providing an onboard cold environment for storage of perishable food items, and for the development of packaging and vehicle stowage parameters were investigated in terms of the overall food system design analysis of space shuttle. The degrees of capability for maintaining both a 40 F to 45 F refrigerated temperature and a 0 F and 20 F frozen environment were assessed for the following cooling techniques: (1) phase change (heat sink) concept; (2) thermoelectric concept; (3) vapor cycle concept; and (4) expendable ammonia concept. The parameters considered in the analysis were weight, volume, and spacecraft power restrictions. Data were also produced for packaging and vehicle stowage parameters which are compatible with vehicle weight and volume specifications. Certain assumptions were made for food packaging sizes based on previously generated space shuttle menus. The results of the study are shown, along with the range of meal choices considered.

  19. Advanced Extravehicular Protective System (AEPS) study

    NASA Technical Reports Server (NTRS)

    Williams, J. L.; Webbon, B. W.; Copeland, R. J.

    1972-01-01

    A summary is presented of Advanced Extravehicular Protective Systems (AEPS) for the future missions beyond Skylab in earth orbit, on the lunar surface, and on the Martian surface. The study concentrated on the origination of regenerable life support concepts for use in portable extravehicular protective systems, and included evaluation and comparison with expendable systems, and selection of life support subsystems. The study was conducted in two phases. In the first phase, subsystem concepts for performing life support functions in AEPS which are regenerable or partially regenerable were originated, and in addition, expendable subsystems were considered. Parametric data for each subsystem concept were evolved including subsystem weight and volume, power requirement, thermal control requirement; base regeneration equipment weight and volume, requirement. The second phase involved an evaluation of the impact of safety considerations involving redundant and/or backup systems on the selection of the regenerable life support subsystems. In addition, the impact of the space shuttle program on regenerable life support subsystem development was investigated.

  20. Maxillomandibular Volume Influences the Relationship between Weight Loss and Improvement in Obstructive Sleep Apnea

    PubMed Central

    Sutherland, Kate; Phillips, Craig L.; Yee, Brendon J.; Grunstein, Ronald R.; Cistulli, Peter A.

    2016-01-01

    Study Objectives: Obesity is the major risk factor for OSA; however, weight loss reduces OSA to a variable extent. We aimed to assess whether size of the maxillomandibular skeletal enclosure influences the relationship between weight loss and OSA reduction. Methods: Obese males (≥ 30 kg/m2) with moderate-severe OSA (AHI > 15/h) participating in a 6-mo open-label weight loss program had craniofacial computed tomography (CT) scans before and after weight loss. CT scans were analysed using three-dimensional cephalometry. Maxillomandibular volume was calculated from skeletal landmarks on the mandible (condyle, gonion, menton) and maxilla (anterior nasal spine). Multiple regression analysis was used to test for moderating effects of maxillomandibular volume on relationship between changes in weight and apnea-hypopnea index (AHI). Results: Fifty-two men (age 44.3 ± 8.8 y, AHI 42.9 ± 21.3 events/h, body mass index [BMI] 34.0 ± 2.7 kg/m2) had 7.4 ± 4.1% weight loss and 34.1 ± 32.4% AHI reduction at 6 months. BMI reduction modestly predicted AHI change (r2 = 0.17, P = 0.002). The interaction term of maxillomandibular volume and BMI change was a predictor of OSA improvement (P = 0.03), indicating maxillomandibular volume moderates this relationship. Subgroup analyses of patients by small, medium, and large maxillomandibular volume showed a strong correlation between weight loss and OSA improvement only in the small volume group (r = 0.654, P = 0.004). There was no relationship evident in those with large maxillomandibular volume (r = 0.05, P = 0.9). Conclusion: Maxillomandibular volume influences the relationship between weight loss and OSA improvement with an effect on AHI more evident in those with a smaller craniofacial skeleton. Citation: Sutherland K, Phillips CL, Yee BJ, Grunstein RR, Cistulli PA. Maxillomandibular volume influences the relationship between weight loss and improvement in obstructive sleep apnea. SLEEP 2016;39(1):43–49. PMID:26350470

  1. Thermal Battery Operating Gas Atmosphere Control and Heat Transfer Optimization

    DTIC Science & Technology

    2012-09-01

    volume of water vapor present at 21.8 C in sample bottles std atm cc 1.533645 Maximum volume of water vapor present at 21.8 C in gas handling system and...sample bottles std atm cc Comparison of gas volumes measured at 838.197 and 1682.297 seconds shows that no water vapor was present and that the gas reacted...temperature of 22.0 ºC torr 0.241556 Maximum volume of water vapor present in one sample bottle std atm cc 0.000194 Maximum weight of water vapor present

  2. Loblolly Pine Growth and Yield Prediction for Managed West Gulf Plantations

    Treesearch

    V. Clark Baldwin; D.P. Feduccia

    1987-01-01

    Complete description, including tables, graphs, computer output, of a growth and yield prediction system providing volume and weight yields in stand and stock table format. An example of system use is given along with information about the computer program, COMPUTE P-LOB, that operates the system.

  3. High molecular weight hydroxyethyl starch solutions are not more effective than a low wmolecular weight hydroxyethyl starch solution in a porcine model of septic shock.

    PubMed

    Simon, T-P; Schuerholz, T; Haugvik, S P; Forberger, C; Burmeister, M-A; Marx, G

    2013-01-01

    There is evidence that suggests that early fluid resuscitation is beneficial in the treatment of sepsis. We previously demonstrated that hydroxyethyl starch (HES) 130/0.42 attenuated capillary leakage better than HES 200/0.5. Using a similar porcine fecal sepsis model, we tested the effects of two new synthetic high molecular weight (700 kDa) hydroxyethyl starches with the same molar substitution of 0.42 but with a different C2/C6 ratio compared to 6% HES 130/0.42 on plasma volume (PV), systemic and tissue oxygenation. This was a prospective, randomized, controlled animal study. Twenty-five anesthetized and mechanically ventilated pigs (28.4±2.3 kg) were observed over 8 h. Septic shock was induced with fecal peritonitis. Animals were randomized for volume-replacement therapy with HES 700/0.42 C2/C6/2.5:1 (N.=5), HES 700/0.42 C2/C6/6:1 (N.=5), HES 130/0.42 C2/C6/5:1 (N.=5) or Ringer’s Solution (RS, N.=5), and compared to non-septic controls receiving RS (N.=5). The albumin escape rate (AER) was calculated and plasma volume was determined at the end of the study. Tissue Oxygen Saturation was measured with the InSpectra™ Device (InSpectra Tissue Spectrometer, Hutchinson Technology Inc., Hutchinson, MN, USA). The AER increased in all groups compared to control. All colloids (HES 700/6:1 68±15; HES 130 67±4; HES 700/2.5:1 71±12; P<0.05) but not RS (44±7) stabilized PV (mL/kg BW) after eight hours of sepsis. Systemic oxygenation was significantly lower in the RS group (44±17%; P<0.05) compared to all other groups at study end (P<0.05). In this porcine fecal peritonitis model, the high molecular weight artificial colloids HES 700/2.5:1 and HES 700/6:1 were not more effective in maintaining plasma volume and systemic and tissue oxygenation than HES 130. In comparison to crystalloid RS, all HES solutions were more effective at maintaining plasma volume, mean arterial pressure (MAP), and systemic and tissue oxygenation.

  4. Container System Hardware (1992) Status Report

    DTIC Science & Technology

    1992-01-01

    high ). The 35’ special-purpose flatracks were designed specifically for use on-board the T- AKR and are capable of carrying a maximum cargo ...primarily to ship ammunition having a high weight to volume ratio such as 155mm projectiles. STATUS In August 1989, the Navy awarded a contract to...and have external dimensions of 8’ wide, 8’ high , and 20’ long. Gross shipping weight is 20,000 pounds with a tare weight of approximately

  5. The Influence of the Orbera Intragastric Balloon Filling Volumes on Weight Loss, Tolerability, and Adverse Events: a Systematic Review and Meta-Analysis.

    PubMed

    Kumar, Nitin; Bazerbachi, Fateh; Rustagi, Tarun; McCarty, Thomas R; Thompson, Christopher C; Galvao Neto, Manoel P; Zundel, Natan; Wilson, Erik B; Gostout, Christopher J; Abu Dayyeh, Barham K

    2017-09-01

    The Orbera intragastric balloon (IGB) has been approved by the US Food and Drug Administration for use in patients with a body mass index (BMI) between 30 and 40 kg/m 2 and is in wide use worldwide as a primary and bridge obesity management tool. The balloon filling volume (BFV) ranges between 400 and 700 mL of saline. Our objective was to determine whether there is an association between BFV and clinically relevant endpoints, namely weight loss outcomes, balloon tolerability, and adverse events. A systematic review of studies investigating the use of the Orbera IGB system for obesity treatment was performed. Data was examined using random effects modelling and meta-regression analyses. Forty-four studies (n = 5549 patients) reported BFV and % total body weight loss (TBWL) at 6 months. Pooled %TBWL at 6 months was 13.2% [95% CI 12.3-14.0]. A funnel plot demonstrated a low risk of publication bias. Meta-regression showed no statistically significant association between filling volume and %TBWL at 6 months (p = 0.268). Higher BFV was associated with lower rates of esophagitis (slope = -0.008, p < 0.001) and prosthesis migration (slope = -0.015, p < 0.001). There was no association between BFV and early removal (p = 0.1), gastroesophageal reflux symptom (p = 0.64), or ulcer rates (p = 0.09). No association was observed between Orbera IGB filling volume and weight loss outcomes. Higher volumes appear to be associated with lower migration and esophagitis rates; thus, a balloon filling volume of 600-650 mL is recommended.

  6. Phase 1 engineering and technical data report for the thermal control extravehicular life support system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A shuttle EVLSS Thermal Control System (TCS) is defined. Thirteen heat rejection subsystems, thirteen water management subsystems, nine humidity control subsystems, three pressure control schemes and five temperature control schemes are evaluated. Sixteen integrated TCS systems are studied, and an optimum system is selected based on quantitative weighting of weight, volume, cost, complexity and other factors. The selected sybsystem contains a sublimator for heat rejection, a bubble expansion tank for water management, and a slurper and rotary separator for humidity control. Design of the selected subsystem prototype hardware is presented.

  7. Stand Structure and Yields of Site-Prepared Loblolly Pine Plantations in the Lower Coastal Plain of the Carolinas, Georgia, and North Florida

    Treesearch

    Jerome L. Clutter; William R. Harms; Graham H. Brister; John W. Reney

    1984-01-01

    Equations and tables are presented for estimating total and merchantable volumes and weights of loblolly pine planted on prepared sites in the Lower Atlantic Coastal Plain.The equation system can be used to predict current and projected yields in cubic feet and green and dry weights.

  8. Quiet Clean Short-Haul Experimental Engine (QCSEE). Preliminary analyses and design report, volume 2

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The experimental and flight propulsion systems are presented. The following areas are discussed: engine core and low pressure turbine design; bearings and seals design; controls and accessories design; nacelle aerodynamic design; nacelle mechanical design; weight; and aircraft systems design.

  9. Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants.

    PubMed

    Rankin, Michael W; Jimenez, Elizabeth Yakes; Caraco, Marina; Collinson, Marie; Lostetter, Lisa; DuPont, Tara L

    2016-11-01

    To evaluate the accuracy of pre- and postfeeding weights to estimate enteral feeding volumes in preterm infants. Single-center prospective cohort study of infants 28-36 weeks' corrected age receiving gavage feedings. For each test weight, 3 pre- and 3 postgavage feeding weights were obtained by study personnel, blinded to feeding volume, via a specific protocol. The correlation between test weight difference and actual volume ingested was assessed by the use of summary statistics, Spearman rho, and graphical analyses. The relationship between categorical predictive variables and a predefined acceptable difference (±5 mL) was assessed with the χ 2 or Fisher exact test. A total of 101 test weights were performed in 68 infants. Estimated and actual feeding volumes were highly correlated (r = 0.94, P < .001), with a mean absolute difference of 2.95 mL (SD: 2.70; range: 0, 12.3 mL; 5th, 95th percentile: 0, 9.3); 85% of test weights were within ±5 mL of actual feeding volume and did not vary significantly by corrected age, feeding tube or respiratory support type, feeding duration or volume, formula vs breast milk, or caloric density. With adherence to study protocol, 89% of test weights (66/74) were within ±5 mL of actual volume, compared with 71% (19/27, P = .04) when concerns about protocol adherence were noted (eg, difficulty securing oxygen tubing). Via the use of a standard protocol, feeding volumes can be estimated accurately by pre- and postfeeding weights. Test weighing could be a valuable tool to support direct breastfeeding in the neonatal intensive care unit. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Continuing Issues (FY 1979) Regarding DoD Use of the Space Transportation System.

    DTIC Science & Technology

    1979-12-01

    estimates) to the cost of launching experimental payloads In the sortie mode is the analytical verification of compatibility ("Integrsaton") of the experiment...with the Shuttle; the Integration cost mya be reduced by the Air Force by treir proposed "class cargo" generalized integra- tion analysis that, once...camactness and light weight (for a given experimental weight) rather than on intrinsic cost , to minmize lazc costa as couted by the NASA volume and weight

  11. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  12. Configuration study for a 30 GHz monolithic receive array, volume 2

    NASA Technical Reports Server (NTRS)

    Nester, W. H.; Cleaveland, B.; Edward, B.; Gotkis, S.; Hesserbacker, G.; Loh, J.; Mitchell, B.

    1984-01-01

    The formalism of the sidelobe suppression algorithm and the method used to calculate the system noise figure for a 30 GHz monolithic receive array are presented. Results of array element weight determination and performance studies of a Gregorian aperture image system are also given.

  13. Smaller = Denser, and the Brain Knows It: Natural Statistics of Object Density Shape Weight Expectations

    PubMed Central

    Peters, Megan A. K.; Balzer, Jonathan; Shams, Ladan

    2015-01-01

    If one nondescript object’s volume is twice that of another, is it necessarily twice as heavy? As larger objects are typically heavier than smaller ones, one might assume humans use such heuristics in preparing to lift novel objects if other informative cues (e.g., material, previous lifts) are unavailable. However, it is also known that humans are sensitive to statistical properties of our environments, and that such sensitivity can bias perception. Here we asked whether statistical regularities in properties of liftable, everyday objects would bias human observers’ predictions about objects’ weight relationships. We developed state-of-the-art computer vision techniques to precisely measure the volume of everyday objects, and also measured their weight. We discovered that for liftable man-made objects, “twice as large” doesn’t mean “twice as heavy”: Smaller objects are typically denser, following a power function of volume. Interestingly, this “smaller is denser” relationship does not hold for natural or unliftable objects, suggesting some ideal density range for objects designed to be lifted. We then asked human observers to predict weight relationships between novel objects without lifting them; crucially, these weight predictions quantitatively match typical weight relationships shown by similarly-sized objects in everyday environments. These results indicate that the human brain represents the statistics of everyday objects and that this representation can be quantitatively abstracted and applied to novel objects. Finally, that the brain possesses and can use precise knowledge of the nonlinear association between size and weight carries important implications for implementation of forward models of motor control in artificial systems. PMID:25768977

  14. DEM interpolation weight calculation modulus based on maximum entropy

    NASA Astrophysics Data System (ADS)

    Chen, Tian-wei; Yang, Xia

    2015-12-01

    There is negative-weight in traditional interpolation of gridding DEM, in the article, the principle of Maximum Entropy is utilized to analyze the model system which depends on modulus of space weight. Negative-weight problem of the DEM interpolation is researched via building Maximum Entropy model, and adding nonnegative, first and second order's Moment constraints, the negative-weight problem is solved. The correctness and accuracy of the method was validated with genetic algorithm in matlab program. The method is compared with the method of Yang Chizhong interpolation and quadratic program. Comparison shows that the volume and scaling of Maximum Entropy's weight is fit to relations of space and the accuracy is superior to the latter two.

  15. Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chuanben; Fei, Zhaodong; Chen, Lisha

    This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contoursmore » were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary.« less

  16. A state-of-the-art compact SiC photovoltaic inverter with maximum power point tracking function

    NASA Astrophysics Data System (ADS)

    Ando, Yuji; Oku, Takeo; Yasuda, Masashi; Ushijima, Kazufumi; Matsuo, Hiroshi; Murozono, Mikio

    2018-01-01

    We have developed a 150-W SiC-based photovoltaic (PV)-inverter with the maximum power point tracking (MPPT) function. The newly developed inverter achieved a state-of-the-art combination of the weight (0.79 kg) and the volume (790 mm3) as a 150-250 W class PV-inverter. As compared to the original version that we have previously reported, the weight and volume were decreased by 37% and 38%, respectively. This compactness originated from the optimized circuit structure and the increased density of a wiring circuit. Conversion efficiencies of the MPPT charge controller and the direct current (DC)-alternating current (AC) converter reached 96.4% and 87.6%, respectively. These efficiency values are comparable to those for the original version. We have developed a PV power generation system consisting of this inverter, a spherical Si solar cell module, and a 15-V Li-ion laminated battery. The total weight of the system was below 6 kg. The developed system exhibited stable output power characteristics, even when the weather conditions were fluctuated. These compactness, high efficiencies, and excellent stability clearly indicated the feasibility of SiC power devices even for sub-kW class PV power generation systems.

  17. Estimating load weights with Huber's Cubic Volume formula: a field trial.

    Treesearch

    Dale R. Waddell

    1989-01-01

    Log weights were estimated from the product of Huber's cubic volume formula and green density. Tags showing estimated log weights were attached to logs in the field, and the weights were tallied into a single load weight as logs were assembled for aerial yarding. Accuracy of the estimated load weights was evaluated by comparing the predicted with the actual load...

  18. Study of fail-safe abort system for an actively cooled hypersonic aircraft, volume 2

    NASA Technical Reports Server (NTRS)

    Peeples, M. E.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  19. High-power microstrip switch

    NASA Technical Reports Server (NTRS)

    Choi, S. D.

    1974-01-01

    Switch, which uses only two p-i-n diodes on microstrip substrate, has been developed for application in spacecraft radio systems. Switch features improved power drain, weight, volume, magnetic cleanliness, and reliability, over currently-used circulator and electromechanical switches.

  20. 75 FR 76282 - Domestic Shipping Services Pricing and Mailing Standards Changes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ... when using a qualifying shipping label managed by the PC Postage system used. b. Permit imprint... system used. b. Permit imprint customers. * * * * * 1.8 Determining Single-Piece Weight [Revise the last... imprint customers. c. Priority Mail Open and Distribute (PMOD) customers whose account volume exceeds 600...

  1. Human life support during interplanetary travel and domicile. III - Mars expedition system trade study

    NASA Technical Reports Server (NTRS)

    Seshan, P. K.; Ferrall, Joseph F.; Rohatgi, Naresh K.

    1991-01-01

    Several alternative configurations of life-support systems (LSSs) for a Mars missions are compared analytically on a quantitative basis in terms of weight, volume, and power. A baseline technology set is utilized for the illustrations of systems including totally open loop, carbon dioxide removal only, partially closed loop, and totally closed loop. The analytical model takes advantage of a modular, top-down hierarchical breakdown of LSS subsystems into functional elements that represent individual processing technologies. The open-loop systems are not competitive in terms of weight for both long-duration orbiters and short-duration lander vehicles, and power demands are lowest with the open loop and highest with the closed loop. The closed-loop system can reduce vehicle weight by over 70,000 lbs and thereby overcome the power penalty of 1600 W; the closed-loop variety is championed as the preferred system for a Mars expedition.

  2. New Internet search volume-based weighting method for integrating various environmental impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, Changyoon, E-mail: changyoon@yonsei.ac.kr; Hong, Taehoon, E-mail: hong7@yonsei.ac.kr

    Weighting is one of the steps in life cycle impact assessment that integrates various characterized environmental impacts as a single index. Weighting factors should be based on the society's preferences. However, most previous studies consider only the opinion of some people. Thus, this research proposes a new weighting method that determines the weighting factors of environmental impact categories by considering public opinion on environmental impacts using the Internet search volumes for relevant terms. To validate the new weighting method, the weighting factors for six environmental impacts calculated by the new weighting method were compared with the existing weighting factors. Themore » resulting Pearson's correlation coefficient between the new and existing weighting factors was from 0.8743 to 0.9889. It turned out that the new weighting method presents reasonable weighting factors. It also requires less time and lower cost compared to existing methods and likewise meets the main requirements of weighting methods such as simplicity, transparency, and reproducibility. The new weighting method is expected to be a good alternative for determining the weighting factor. - Highlight: • A new weighting method using Internet search volume is proposed in this research. • The new weighting method reflects the public opinion using Internet search volume. • The correlation coefficient between new and existing weighting factors is over 0.87. • The new weighting method can present the reasonable weighting factors. • The proposed method can be a good alternative for determining the weighting factors.« less

  3. A high-temperature furnace for applications in microgravity

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Technology in the area of material processing and crystal growth has been greatly furthered by research in microgravity environments. The role of efficient, lightweight furnaces with reliable performance is crucial in these experiments. A need exists for the development of a readily duplicated, high-temperature furnace satisfying stringent weight, volume, and power constraints. A furnace was designed and is referred to as the UAH SHIELD. Stringent physical and operating characteristics for the system were specified, including a maximum weight of 20 kg, a maximum power requirement of 60 W, and a volume of the furnace assembly, excluding the batteries, limited to half a Get-Away-Special canister. The UAH SHIELD furnace uses radiation shield and vacuum technology applied in the form of a series of concentric cylinders enclosed on either end with disks. Thermal testing of a furnace prototype was performed in addition to some thermal and structural analysis. Results indicate the need for spacing of the shields to accommodate the thermal expansion during furnace operation. In addition, a power dissipation of approximately 100 W and system weight of approximately 30 kg was found for the current design.

  4. Tumor Volume and Patient Weight as Predictors of Outcome in Children with Intermediate Risk Rhabdomyosarcoma (RMS): A Report from the Children’s Oncology Group

    PubMed Central

    Rodeberg, David A.; Stoner, Julie A.; Garcia-Henriquez, Norbert; Randall, R. Lor; Spunt, Sheri L.; Arndt, Carola A.; Kao, Simon; Paidas, Charles N.; Million, Lynn; Hawkins, Douglas S.

    2010-01-01

    Background To compare tumor volume and patient weight vs. traditional factors of tumor diameter and patient age, to determine which parameters best discriminates outcome among intermediate risk RMS patients. Methods Complete patient information for non-metastatic RMS patients enrolled in the Children’s Oncology Group (COG) intermediate risk study D9803 (1999–2005) was available for 370 patients. The Kaplan-Meier method was used to estimate survival distributions. A recursive partitioning model was used to identify prognostic factors associated with event-free survival (EFS). Cox-proportional hazards regression models were used to estimate the association between patient characteristics and the risk of failure or death. Results For all intermediate risk patients with RMS, a recursive partitioning algorithm for EFS suggests that prognostic groups should optimally be defined by tumor volume (transition point 20 cm3), weight (transition point 50 kg), and embryonal histology. Tumor volume and patient weight added significant outcome information to the standard prognostic factors including tumor diameter and age (p=0.02). The ability to resect the tumor completely was not significantly associated with the size of the patient, and patient weight did not significantly modify the association between tumor volume and EFS after adjustment for standard risk factors (p=0.2). Conclusion The factors most strongly associated with EFS were tumor volume, patient weight, and histology. Based on regression modeling, volume and weight are superior predictors of outcome compared to tumor diameter and patient age in children with intermediate risk RMS. Prognostic performance of tumor volume and patient weight should be assessed in an independent prospective study. PMID:24048802

  5. Inhibition of growth of experimental prostate cancer with sustained delivery systems (microcapsules and microgranules) of the luteinizing hormone-releasing hormone antagonist SB-75.

    PubMed Central

    Korkut, E; Bokser, L; Comaru-Schally, A M; Groot, K; Schally, A V

    1991-01-01

    Inhibitory effects of the sustained delivery systems (microcapsules and microgranules) of a potent antagonist of luteinizing hormone-releasing hormone N-Ac-[3-(2-naphthyl)-D-alanine1, 4-chloro-D-phenylalanine2, 3-(3-pyridyl)-D-alanine3, D-citrulline6, D-alanine10]LH-RH (SB-75) on the growth of experimental prostate cancers were investigated. In the first experiment, three doses of a microcapsule preparation releasing 23.8, 47.6, and 71.4 micrograms of antagonist SB-75 per day were compared with microcapsules of agonist [D-Trp6]LH-RH liberating 25 micrograms/day in rats bearing Dunning R3327H transplantable prostate carcinoma. During 8 weeks of treatment, tumor growth was decreased by [D-Trp6]LH-RH and all three doses of SB-75 as compared to untreated controls. The highest dose of SB-75 (71.4 micrograms/day) caused a greater inhibition of prostate cancer growth than [D-Trp6]LH-RH as based on measurement of tumor volume and percentage change in tumor volume. Doses of 23.8 and 47.6 micrograms of SB-75 per day induced a partial and submaximal decrease, respectively, in tumor weight and volume. Tumor doubling time was the longest (50 days) with the high dose of SB-75 vs. 15 days for controls. The body weights were unchanged. The weights of testes, seminal vesicles, and ventral prostate were greatly reduced in all three groups that received SB-75, and testosterone levels were decreased to nondetectable values in the case of the two higher doses of SB-75. LH levels were also diminished. Similar results were obtained in the second experiment, in which the animals were treated for a period of 8 weeks with microgranules of SB-75. Therapy with microgranules of SB-75 significantly decreased tumor growth as measured by the final tumor volume, the percentage change from the initial tumor volume, and the reduction in tumor weight. The results indicate that antagonist SB-75, released from sustained delivery systems, can produce a state of chemical castration and effectively inhibit the growth of experimental prostate cancers. The efficacy of the antagonist SB-75 in inhibiting androgen-dependent Dunning prostatic carcinoma and the absence of side effects suggest its possible usefulness for the treatment of hormone-sensitive tumors. PMID:1992476

  6. Inhibition of growth of experimental prostate cancer with sustained delivery systems (microcapsules and microgranules) of the luteinizing hormone-releasing hormone antagonist SB-75.

    PubMed

    Korkut, E; Bokser, L; Comaru-Schally, A M; Groot, K; Schally, A V

    1991-02-01

    Inhibitory effects of the sustained delivery systems (microcapsules and microgranules) of a potent antagonist of luteinizing hormone-releasing hormone N-Ac-[3-(2-naphthyl)-D-alanine1, 4-chloro-D-phenylalanine2, 3-(3-pyridyl)-D-alanine3, D-citrulline6, D-alanine10]LH-RH (SB-75) on the growth of experimental prostate cancers were investigated. In the first experiment, three doses of a microcapsule preparation releasing 23.8, 47.6, and 71.4 micrograms of antagonist SB-75 per day were compared with microcapsules of agonist [D-Trp6]LH-RH liberating 25 micrograms/day in rats bearing Dunning R3327H transplantable prostate carcinoma. During 8 weeks of treatment, tumor growth was decreased by [D-Trp6]LH-RH and all three doses of SB-75 as compared to untreated controls. The highest dose of SB-75 (71.4 micrograms/day) caused a greater inhibition of prostate cancer growth than [D-Trp6]LH-RH as based on measurement of tumor volume and percentage change in tumor volume. Doses of 23.8 and 47.6 micrograms of SB-75 per day induced a partial and submaximal decrease, respectively, in tumor weight and volume. Tumor doubling time was the longest (50 days) with the high dose of SB-75 vs. 15 days for controls. The body weights were unchanged. The weights of testes, seminal vesicles, and ventral prostate were greatly reduced in all three groups that received SB-75, and testosterone levels were decreased to nondetectable values in the case of the two higher doses of SB-75. LH levels were also diminished. Similar results were obtained in the second experiment, in which the animals were treated for a period of 8 weeks with microgranules of SB-75. Therapy with microgranules of SB-75 significantly decreased tumor growth as measured by the final tumor volume, the percentage change from the initial tumor volume, and the reduction in tumor weight. The results indicate that antagonist SB-75, released from sustained delivery systems, can produce a state of chemical castration and effectively inhibit the growth of experimental prostate cancers. The efficacy of the antagonist SB-75 in inhibiting androgen-dependent Dunning prostatic carcinoma and the absence of side effects suggest its possible usefulness for the treatment of hormone-sensitive tumors.

  7. Biennial Guidance Test Symposium (13th) Held in Holloman Air Force Base, New Mexico on 6-8 October 1987. Volume 1

    DTIC Science & Technology

    1987-10-15

    Guardiani, R. Strane, J. Profeta, Contraves Goerz Corporation, 610 Epsilon Dr., Pittsburg PA S04A "The Global Positioning System as an Aid to the Testing...errors. The weights defining the current error state as a linear combination of the gravity errors at the previous vehicle locations are maintained and...updated at each time step. These weights can also be used to compute the cross-correlation of the system errors with measured gravity quantities for use

  8. Advanced transportation system studies technical area 3: Alternate propulsion subsystem concepts, volume 3

    NASA Technical Reports Server (NTRS)

    Levak, Daniel

    1993-01-01

    The objective of this contract was to provide definition of alternate propulsion systems for both earth-to-orbit (ETO) and in-space vehicles (upper stages and space transfer vehicles). For such propulsion systems, technical data to describe performance, weight, dimensions, etc. was provided along with programmatic information such as cost, schedule, needed facilities, etc. Advanced technology and advanced development needs were determined and provided. This volume separately presents the various program cost estimates that were generated under three tasks: the F-1A Restart Task, the J-2S Restart Task, and the SSME Upper Stage Use Task. The conclusions, technical results, and the program cost estimates are described in more detail in Volume 1 - Executive Summary and in individual Final Task Reports.

  9. Advanced Transportation System Studies. Technical Area 3: Alternate Propulsion Subsystems Concepts. Volume 3; Program Cost Estimates

    NASA Technical Reports Server (NTRS)

    Levack, Daniel J. H.

    2000-01-01

    The objective of this contract was to provide definition of alternate propulsion systems for both earth-to-orbit (ETO) and in-space vehicles (upper stages and space transfer vehicles). For such propulsion systems, technical data to describe performance, weight, dimensions, etc. was provided along with programmatic information such as cost, schedule, needed facilities, etc. Advanced technology and advanced development needs were determined and provided. This volume separately presents the various program cost estimates that were generated under three tasks: the F- IA Restart Task, the J-2S Restart Task, and the SSME Upper Stage Use Task. The conclusions, technical results , and the program cost estimates are described in more detail in Volume I - Executive Summary and in individual Final Task Reports.

  10. Magnetic Resonance Venous Volume Measurements in Peripheral Artery Disease (from ELIMIT).

    PubMed

    Kamran, Hassan; Nambi, Vijay; Negi, Smita; Yang, Eric Y; Chen, Changyi; Virani, Salim S; Kougias, Panos; Lumsden, Alan B; Morrisett, Joel D; Ballantyne, Christie M; Brunner, Gerd

    2016-11-01

    The relation between the arterial and venous systems in patients with impaired lower extremity blood flow remains poorly described. The objective of this secondary analysis of the Effectiveness of Intensive Lipid Modification Medication in Preventing the Progression on Peripheral Artery Disease Trial was to determine the association between femoral vein (FV) volumes and measurements of peripheral artery disease. FV wall, lumen, and total volumes were quantified with fast spin-echo proton density-weighted magnetic resonance imaging scans in 79 patients with peripheral artery disease over 2 years. Reproducibility was excellent for FV total vessel (intraclass correlation coefficient 0.924, confidence interval 0.910 to 0.935) and lumen volumes (intraclass correlation coefficient 0.893, confidence interval 0.873 to 0.910). Baseline superficial femoral artery volumes were directly associated with FV wall (r = 0.46, p <0.0001), lumen (r = 0.42, p = 0.0001), and total volumes (r = 0.46, p <0.0001). The 2-year change in maximum walking time was inversely associated with the 24-month change in FV total volume (r = -0.45, p = 0.03). In conclusion, FV volumes can be measured reliably with fast spin-echo proton density-weighted magnetic resonance imaging, and baseline superficial femoral artery plaque burden is positively associated with FV volumes, whereas the 2-year change in FV volumes and leg function show an inverse relation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Brain Structural Differences between Normal and Obese Adults and their Links with Lack of Perseverance, Negative Urgency, and Sensation Seeking.

    PubMed

    Wang, Haifeng; Wen, Baohong; Cheng, Jingliang; Li, Hongpeng

    2017-01-16

    In order to examine the difference in brain structure between obese and normal weight individuals, and to explore the relationship between the neuroanatomical changes and impulsivity traits, this study used a voxel-based morphometry method to examine gray matter (GM) volume alterations related to impulsive personality traits in obese individuals relative to normal weight. Eighty adults that completed the UPPS-P Impulsive Behavior Scale were analyzed. Possible GM volume alterations were first analyzed at the whole brain level, and then the relationship between regional GM volume differences and UPPS-P scores were examined in selected regions of interest. Reduced GM volumes were found in the frontal and limbic regions in the obese group compared to normal weight individuals. In the normal weight group, lack of perseverance was negatively correlated with GM volume in the anterior cingulate cortex, and negative urgency was negatively correlated with GM volume in the insula. In the obese group, sensation seeking was negatively correlated with GM volume in the left amygdala and right pallidum. These findings might improve our understanding of the relationship between lack of perseverance, negative urgency, and sensation seeking and body weight fluctuations.

  12. Brain Structural Differences between Normal and Obese Adults and their Links with Lack of Perseverance, Negative Urgency, and Sensation Seeking

    PubMed Central

    Wang, Haifeng; Wen, Baohong; Cheng, Jingliang; Li, Hongpeng

    2017-01-01

    In order to examine the difference in brain structure between obese and normal weight individuals, and to explore the relationship between the neuroanatomical changes and impulsivity traits, this study used a voxel-based morphometry method to examine gray matter (GM) volume alterations related to impulsive personality traits in obese individuals relative to normal weight. Eighty adults that completed the UPPS-P Impulsive Behavior Scale were analyzed. Possible GM volume alterations were first analyzed at the whole brain level, and then the relationship between regional GM volume differences and UPPS-P scores were examined in selected regions of interest. Reduced GM volumes were found in the frontal and limbic regions in the obese group compared to normal weight individuals. In the normal weight group, lack of perseverance was negatively correlated with GM volume in the anterior cingulate cortex, and negative urgency was negatively correlated with GM volume in the insula. In the obese group, sensation seeking was negatively correlated with GM volume in the left amygdala and right pallidum. These findings might improve our understanding of the relationship between lack of perseverance, negative urgency, and sensation seeking and body weight fluctuations. PMID:28091559

  13. The Moisture Content and Specific Gravity of the Bark and Wood of Northern Pulpwood Species

    Treesearch

    John R. Erickson

    1972-01-01

    Much information is available on the specific gravity of wood on a dry weight over green volume and dry weight over dry volume basis. This paper presents the conventional specific gravity on a green weight over green volume basis. The relative specific gravities of bark and wood chips may be helpful in finding way to remove bark particles from chips.

  14. The effect of lung-size mismatch on mechanical ventilation tidal volumes after bilateral lung transplantation.

    PubMed

    Dezube, Rebecca; Arnaoutakis, George J; Reed, Robert M; Bolukbas, Servet; Shah, Ashish S; Orens, Jonathan B; Brower, Roy G; Eberlein, Michael

    2013-03-01

    Mechanical ventilation tidal volumes are usually set according to an estimate of patient size in millilitres (ml) per kilogram (kg) body weight. We describe the relationship between donor-recipient lung-size mismatch and postoperative mechanical ventilation tidal volumes according to recipient- and donor-predicted body weights in a cohort of bilateral lung transplant patients. A most-undersized (10 patients with lowest predicted total lung capacity [pTLC] ratio = pTLC-donor/pTLC-recipient), a most-oversized (10 patients with highest pTLC ratio) and best-matched subset (10 patients with predicted total lung capacity ratio closest to 1.0) were selected within a cohort of 70 patients. All tidal volumes during mechanical ventilation in the first 96 h after bilateral lung transplantation were recorded. Tidal volumes were expressed in ml and ml/kg-recipient-predicted body weights and ml/kg-donor-predicted body weights. Postoperative absolute tidal volumes (in ml) were comparable between subsets of patients with undersized, matched and oversized allografts (552 ± 103 vs 581 ± 107 vs 582 ± 104 ml), and tidal volumes in ml/kg-recipient-predicted body weights were also similar (8.8 ± 1.4 vs 9.3 ± 1.1 vs 9.8 ± 2.1). However, tidal volumes in ml/kg-donor-predicted body weights revealed significant differences between undersized, matched, and oversized subsets (11.4 ± 3.1 vs 9.4 ± 1.2 vs 8.1 ± 2.1, respectively; P < 0.05). Two patients developed primary graft dysfunction grade 3, both in the undersized subset. Four patients in the undersized group underwent tracheotomy (vs none in matched and one in oversized subset). During mechanical ventilation after bilateral lung transplantation, undersized allografts received relatively higher tidal volumes compared with oversized allografts when the tidal volumes were related to donor-predicted body weights.

  15. The anti-inflammatory effect of diclofenac is considerably augmented by topical capsaicinoids-containing patch in carrageenan-induced paw oedema of rat.

    PubMed

    Ercan, Nilufer; Uludag, Mecit Orhan; Agis, Erol Rauf; Demirel-Yilmaz, Emine

    2013-12-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are the most used drugs in musculoskeletal disorders, but their systemic adverse effects limit their therapeutic benefit in local inflammation. On the other hand, topical preparations of capsaicinoids are widely used for musculoskeletal disorders as a complementary therapy. In this study, the effects of both topical capsaicinoids-containing patch and local subcutaneous capsaicin application on the anti-inflammatory action of NSAID were examined. Carrageenan-induced paw oedema of rats was used as the inflammation model. The volume and weight of the paw oedema and plasma extravasation in the paw were determined after carrageenan injection. The systemic application of diclofenac (3 mg/kg), which is an NSAID, significantly decreased the volume and weight of the paw oedema. Topical capsaicinoids-containing patch application or local capsaicin injection (2, 10, 20 μg/paw) alone did not cause any effect on oedema volume and weight. However, the combination of diclofenac with topical capsaicinoids-containing patch significantly increased the effectiveness of diclofenac on inflammation. Evans blue content of the paws that represents plasma extravasation was decreased by capsaicinoids-containing patch with and without diclofenac and diclofenac combination with the lowest dose of capsaicin injection. The results of this study indicate that topical application of capsaicinoids-containing patch enhances the anti-inflammatory effect of diclofenac and its beneficial effect may not purely relate to its capsaicin content. In the treatment of local inflammatory disorders, the combination of NSAID with topical capsaicinoids-containing patch could increase the anti-inflammatory efficiency of drug without systemic side effects.

  16. Estimating sugar maple bark thickness and volume.

    Treesearch

    Charles L. Stayton; Michael Hoffman

    1970-01-01

    Sugar maple bark thickness and volume were estimated using first a published method, then equations developed by the authors. Both methods gave estimates that compared closely with measured values. Information is also presented on variation in bark thickness and on weight and volume of bark as a percentage of total merchantable stem weight and volume.

  17. Metrics for Mechanics and Other Practical People.

    ERIC Educational Resources Information Center

    Richmond, Doug

    This handbook on the metric system is printed in a large type for ease of reading. It includes several tables of often-used facts. A brief background of the metric system is presented, followed by chapters on metric uses with electricity, length, pressure, temperature, threaded fastenings, tools, torque, volume, and weight. Each chapter provides a…

  18. Aerospace applications of magnetic bearings

    NASA Technical Reports Server (NTRS)

    Downer, James; Goldie, James; Gondhalekar, Vijay; Hockney, Richard

    1994-01-01

    Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.

  19. Aerospace applications of magnetic bearings

    NASA Astrophysics Data System (ADS)

    Downer, James; Goldie, James; Gondhalekar, Vijay; Hockney, Richard

    1994-05-01

    Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.

  20. Lung protection: an intervention for tidal volume reduction in a teaching intensive care unit.

    PubMed

    Briva, Arturo; Gaiero, Cristina

    2016-01-01

    To determine the effect of feedback and education regarding the use of predicted body weight to adjust tidal volume in a lung-protective mechanical ventilation strategy. The study was performed from October 2014 to November 2015 (12 months) in a single university polyvalent intensive care unit. We developed a combined intervention (education and feedback), placing particular attention on the importance of adjusting tidal volumes to predicted body weight bedside. In parallel, predicted body weight was estimated from knee height and included in clinical charts. One hundred fifty-nine patients were included. Predicted body weight assessed by knee height instead of visual evaluation revealed that the delivered tidal volume was significantly higher than predicted. After the inclusion of predicted body weight, we observed a sustained reduction in delivered tidal volume from a mean (standard error) of 8.97 ± 0.32 to 7.49 ± 0.19mL/kg (p < 0.002). Furthermore, the protocol adherence was subsequently sustained for 12 months (delivered tidal volume 7.49 ± 0.54 versus 7.62 ± 0.20mL/kg; p = 0.103). The lack of a reliable method to estimate the predicted body weight is a significant impairment for the application of a worldwide standard of care during mechanical ventilation. A combined intervention based on education and repeated feedbacks promoted sustained tidal volume education during the study period (12 months).

  1. Continuous prestressed concrete girder bridges, volume 2 : analysis, testing, and recommendations.

    DOT National Transportation Integrated Search

    2016-12-01

    The Texas Department of Transportation designs typical highway bridge structures as simple span systems using : standard precast, pretensioned girders. Spans are limited to about 150 ft due to weight and length restrictions on : transporting the prec...

  2. Study of a fail-safe abort system for an actively cooled hypersonic aircraft. Volume 1: Technical summary

    NASA Technical Reports Server (NTRS)

    Pirello, C. J.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  3. CONFERENCE Proceedings of the computer Aided System Design and Simulation (50th) Held in Cesme/Ismir, Turkey on 22-25 May 1990 (Systeme de Conception Aide par Ordinateur et Simulation)

    DTIC Science & Technology

    1990-05-01

    vital problem. During flight conditions a sensor, or a combination of sensors might undergo a failure, causing the loss of sensor signals that are...by solving the optimization problem max I k - k I(Z 00 (55) d(zk) e n V~ l where k denotes the nominal sensor gains and I1.11 denotes the weighted I...the Weapon System. Parameters like volume and weight have to be approximately defined at the begining of this phase. It is equally important to obtain

  4. Subsystems component definitions summary program

    NASA Technical Reports Server (NTRS)

    Scott, A. Don; Thomas, Carolyn C.; Simonsen, Lisa C.; Hall, John B., Jr.

    1991-01-01

    A computer program, the Subsystems Component Definitions Summary (SUBCOMDEF), was developed to provide a quick and efficient means of summarizing large quantities of subsystems component data in terms of weight, volume, resupply, and power. The program was validated using Space Station Freedom Program Definition Requirements Document data for the internal and external thermal control subsystem. Once all component descriptions, unit weights and volumes, resupply, and power data are input, the user may obtain a summary report of user-specified portions of the subsystem or of the entire subsystem as a whole. Any combination or all of the parameters of wet and dry weight, wet and dry volume, resupply weight and volume, and power may be displayed. The user may vary the resupply period according to individual mission requirements, as well as the number of hours per day power consuming components operate. Uses of this program are not limited only to subsystem component summaries. Any applications that require quick, efficient, and accurate weight, volume, resupply, or power summaries would be well suited to take advantage of SUBCOMDEF's capabilities.

  5. Optically controlled phased-array antenna technology for space communication systems

    NASA Technical Reports Server (NTRS)

    Kunath, Richard R.; Bhasin, Kul B.

    1988-01-01

    Using MMICs in phased-array applications above 20 GHz requires complex RF and control signal distribution systems. Conventional waveguide, coaxial cable, and microstrip methods are undesirable due to their high weight, high loss, limited mechanical flexibility and large volume. An attractive alternative to these transmission media, for RF and control signal distribution in MMIC phased-array antennas, is optical fiber. Presented are potential system architectures and their associated characteristics. The status of high frequency opto-electronic components needed to realize the potential system architectures is also discussed. It is concluded that an optical fiber network will reduce weight and complexity, and increase reliability and performance, but may require higher power.

  6. Flight Weight Design Nickel-Hydrogen Cells Using Lightweight Nickel Fiber Electrodes

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.; Willis, Bob; Pickett, David F.

    2003-01-01

    The goal of this program is to develop a lightweight nickel electrode for advanced aerospace nickel-hydrogen cells and batteries with improved specific energy and specific volume. The lightweight nickel electrode will improve the specific energy of a nickel-hydrogen cell by >50%. These near-term advanced batteries will reduce power system mass and volume, while decreasing the cost, thus increasing mission capabilities and enabling small spacecraft missions. This development also offers a cost savings over the traditional sinter development methods for fabrication. The technology has been transferred to Eagle-Picher, a major aerospace battery manufacturer, who has scaled up the process developed at NASA GRC and fabricated electrodes for incorporation into flight-weight nickel-hydrogen cells.

  7. Automotive Gas Turbine Power System-Performance Analysis Code

    NASA Technical Reports Server (NTRS)

    Juhasz, Albert J.

    1997-01-01

    An open cycle gas turbine numerical modelling code suitable for thermodynamic performance analysis (i.e. thermal efficiency, specific fuel consumption, cycle state points, working fluid flowrates etc.) of automotive and aircraft powerplant applications has been generated at the NASA Lewis Research Center's Power Technology Division. The use this code can be made available to automotive gas turbine preliminary design efforts, either in its present version, or, assuming that resources can be obtained to incorporate empirical models for component weight and packaging volume, in later version that includes the weight-volume estimator feature. The paper contains a brief discussion of the capabilities of the presently operational version of the code, including a listing of input and output parameters and actual sample output listings.

  8. Shuttle cryogenic supply system optimization study. Volume 2: Technical report, sections 4 through 9

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and development of cryogenic supply systems for space shuttle vehicles are discussed. The weights, component counts, and statements of advantages and disadvantages of the systems considered are presented. Performance characteristics of the systems are analyzed in the form of graphs. Block diagrams and engineering drawings of the candidate systems are provided. Special consideration is given to flow rates and thermodynamic properties of the cryogenic systems.

  9. Poor Adherence to Lung-Protective Mechanical Ventilation in Pediatric Acute Respiratory Distress Syndrome.

    PubMed

    Ward, Shan L; Quinn, Carson M; Valentine, Stacey L; Sapru, Anil; Curley, Martha A Q; Willson, Douglas F; Liu, Kathleen D; Matthay, Michael A; Flori, Heidi R

    2016-10-01

    To determine the frequency of low-tidal volume ventilation in pediatric acute respiratory distress syndrome and assess if any demographic or clinical factors improve low-tidal volume ventilation adherence. Descriptive post hoc analysis of four multicenter pediatric acute respiratory distress syndrome studies. Twenty-six academic PICU. Three hundred fifteen pediatric acute respiratory distress syndrome patients. All patients who received conventional mechanical ventilation at hours 0 and 24 of pediatric acute respiratory distress syndrome who had data to calculate ideal body weight were included. Two cutoff points for low-tidal volume ventilation were assessed: less than or equal to 6.5 mL/kg of ideal body weight and less than or equal to 8 mL/kg of ideal body weight. Of 555 patients, we excluded 240 for other respiratory support modes or missing data. The remaining 315 patients had a median PaO2-to-FIO2 ratio of 140 (interquartile range, 90-201), and there were no differences in demographics between those who did and did not receive low-tidal volume ventilation. With tidal volume cutoff of less than or equal to 6.5 mL/kg of ideal body weight, the adherence rate was 32% at hour 0 and 33% at hour 24. A low-tidal volume ventilation cutoff of tidal volume less than or equal to 8 mL/kg of ideal body weight resulted in an adherence rate of 58% at hour 0 and 60% at hour 24. Low-tidal volume ventilation use was no different by severity of pediatric acute respiratory distress syndrome nor did adherence improve over time. At hour 0, overweight children were less likely to receive low-tidal volume ventilation less than or equal to 6.5 mL/kg ideal body weight (11% overweight vs 38% nonoverweight; p = 0.02); no difference was noted by hour 24. Furthermore, in the overweight group, using admission weight instead of ideal body weight resulted in misclassification of up to 14% of patients as receiving low-tidal volume ventilation when they actually were not. Low-tidal volume ventilation is underused in the first 24 hours of pediatric acute respiratory distress syndrome. Age, Pediatric Risk of Mortality-III, and pediatric acute respiratory distress syndrome severity were not associated with improved low-tidal volume ventilation adherence nor did adherence improve over time. Overweight children were less likely to receive low-tidal volume ventilation strategies in the first day of illness.

  10. Fuel Cell Auxiliary Power Study Volume 1: RASER Task Order 5

    NASA Technical Reports Server (NTRS)

    Mak, Audie; Meier, John

    2007-01-01

    This study evaluated the feasibility of a hybrid solid oxide fuel cell (SOFC) auxiliary power unit (APU) and the impact in a 90-passenger More-Electric Regional Jet application. The study established realistic hybrid SOFC APU system weight and system efficiencies, and evaluated the impact on the aircraft total weight, fuel burn, and emissions from the main engine and the APU during cruise, landing and take-off (LTO) cycle, and at the gate. Although the SOFC APU may be heavier than the current conventional APU, its weight disadvantage can be offset by fuel savings in the higher SOFC APU system efficiencies against the main engine bleed and extraction during cruise. The higher SOFC APU system efficiency compared to the conventional APU on the ground can also provide considerable fuel saving and emissions reduction, particularly at the gate, but is limited by the fuel cell stack thermal fatigue characteristic.

  11. Space Shuttle 2 advanced space transportation system, volume 2

    NASA Technical Reports Server (NTRS)

    Adinaro, James N.; Benefield, Philip A.; Johnson, Shelby D.; Knight, Lisa K.

    1989-01-01

    To determine the best configuration from all candidate configurations, it was necessary first to calculate minimum system weights and performance. To optimize the design, it is necessary to vary configuration-specific variables such as total system weight, thrust-to-weight ratios, burn durations, total thrust available, and mass fraction for the system. Optimizing each of these variables at the same time is technically unfeasible and not necessarily mathematically possible. However, discrete sets of data can be generated which will eliminate many candidate configurations. From the most promising remaining designs, a final configuration can be selected. Included are the three most important designs considered: one which closely approximates the design criteria set forth in a Marshall Space Flight Center study of the Shuttle 2; the configuration used in the initial proposal; and the final configuration. A listing by cell of the formulas used to generate the aforementioned data is included for reference.

  12. Eddy current correction in volume-localized MR spectroscopy

    NASA Technical Reports Server (NTRS)

    Lin, C.; Wendt, R. E. 3rd; Evans, H. J.; Rowe, R. M.; Hedrick, T. D.; LeBlanc, A. D.

    1994-01-01

    The quality of volume-localized magnetic resonance spectroscopy is affected by eddy currents caused by gradient switching. Eddy currents can be reduced with improved gradient systems; however, it has been suggested that the distortion due to eddy currents can be compensated for during postprocessing with a single-frequency reference signal. The authors propose modifying current techniques for acquiring the single-frequency reference signal by using relaxation weighting to reduce interference from components that cannot be eliminated by digital filtering alone. Additional sequences with T1 or T2 weighting for reference signal acquisition are shown to have the same eddy current characteristics as the original signal without relaxation weighting. The authors also studied a new eddy current correction method that does not require a single-frequency reference signal. This method uses two free induction decays (FIDs) collected from the same volume with two sequences with opposite gradients. Phase errors caused by eddy currents are opposite in these two FIDs and can be canceled completely by combining the FIDs. These methods were tested in a phantom. Eddy current distortions were corrected, allowing quantitative measurement of structures such as the -CH = CH- component, which is otherwise undetectable.

  13. [Is there a relation between weight in rats, bone density, ash weight and histomorphometric indicators of trabecular volume and thickness in the bones of extremities?].

    PubMed

    Zák, J; Kapitola, J; Povýsil, C

    2003-01-01

    Authors deal with question, if there is possibility to infer bone histological structure (described by histomorphometric parameters of trabecular bone volume and trabecular thickness) from bone density, ash weight or even from weight of animal (rat). Both tibias of each of 30 intact male rats, 90 days old, were processed. Left tibia was utilized to the determination of histomorphometric parameters of undecalcified bone tissue patterns by automatic image analysis. Right tibia was used to the determination of values of bone density, using Archimedes' principle. Values of bone density, ash weight, ash weight related to bone volume and animal weight were correlated with histomorphometric parameters (trabecular bone volume, trabecular thickness) by Pearson's correlation test. One could presume the existence of relation between data, describing bone mass at the histological level (trabecular bone of tibia) and other data, describing mass of whole bone or even animal mass (weight). But no statistically significant correlation was found. The reason of the present results could be in the deviations of trabecular density in marrow of tibia. Because of higher trabecular bone density in metaphyseal and epiphyseal regions, the histomorphometric analysis of trabecular bone is preferentially done in these areas. It is possible, that this irregularity of trabecular tibial density could be the source of the deviations, which could influence the results of correlations determined. The values of bone density, ash weight and animal weight do not influence trabecular bone volume and vice versa: static histomorphometric parameters of trabecular bone do not reflect bone density, ash weight and weight of animal.

  14. Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume.

    PubMed

    Lemke, Arne-Jörn; Brinkmann, Martin Julius; Schott, Thomas; Niehues, Stefan Markus; Settmacher, Utz; Neuhaus, Peter; Felix, Roland

    2006-09-01

    To prospectively develop equations for the calculation of expected intraoperative weight and volume of a living donor's right liver lobe by using preoperative computed tomography (CT) for volumetric measurement. After medical ethics committee and state medical board approval, informed consent was obtained from eight female and eight male living donors (age range, 18-63 years) for participation in preoperative CT volumetric measurement of the right liver lobes by using the summation-of-area method. Intraoperatively, the graft was weighed, and the volume of the graft was determined by means of water displacement. Distributions of pre- and intraoperative data were depicted as Tukey box-and-whisker diagrams. Then, linear regressions were calculated, and the results were depicted as scatterplots. On the basis of intraoperative data, physical density of the parenchyma was calculated by dividing weight by volume of the graft. Preoperative measurement of grafts resulted in a mean volume of 929 mL +/- 176 (standard deviation); intraoperative mean weight and volume of the grafts were 774 g +/- 138 and 697 mL +/- 139, respectively. All corresponding pre- and intraoperative data correlated significantly (P < .001) with each other. Intraoperatively expected volume (V(intraop)) in millilliters and weight (W(intraop)) in grams can be calculated with the equations V(intra)(op) = (0.656 . V(preop)) + 87.629 mL and W(intra)(op) = (0.678 g/mL . V(preop)) + 143.704 g, respectively, where preoperative volume is V(preop) in milliliters. Physical density of transplanted liver lobes was 1.1172 g/mL +/- 0.1015. By using two equations developed from the data obtained in this study, expected intraoperative weight and volume can properly be determined from CT volumetric measurements. (c) RSNA, 2006.

  15. Space station data system analysis/architecture study. Task 3: Trade studies, DR-5, volume 1

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The primary objective of Task 3 is to provide additional analysis and insight necessary to support key design/programmatic decision for options quantification and selection for system definition. This includes: (1) the identification of key trade study topics; (2) the definition of a trade study procedure for each topic (issues to be resolved, key inputs, criteria/weighting, methodology); (3) conduct tradeoff and sensitivity analysis; and (4) the review/verification of results within the context of evolving system design and definition. The trade study topics addressed in this volume include space autonomy and function automation, software transportability, system network topology, communications standardization, onboard local area networking, distributed operating system, software configuration management, and the software development environment facility.

  16. 19 CFR 146.93 - Inventory control and recordkeeping system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (first-in, first-out) method of accounting (see § 191.22(c) of this chapter). The use of this method is... method, measurement (weight or volume), and the price of product consistently (see § 146.92(g) of this...

  17. Higher Leptin but Not Human Milk Macronutrient Concentration Distinguishes Normal-Weight from Obese Mothers at 1-Month Postpartum.

    PubMed

    De Luca, Arnaud; Frasquet-Darrieux, Marine; Gaud, Marie-Agnès; Christin, Patricia; Boquien, Clair-Yves; Millet, Christine; Herviou, Manon; Darmaun, Dominique; Robins, Richard J; Ingrand, Pierre; Hankard, Régis

    2016-01-01

    Exclusively breastfed infants born to obese mothers have previously been shown to gain less weight by 1-month postpartum than infants of normal-weight mothers. Our hypothesis is that human milk composition and volume may differ between obese and normal-weight mothers. To compare human milk leptin, macronutrient concentration, and volume in obese and normal-weight mothers. Mother and infant characteristics were studied as secondary aims. This cross-sectional observational study compared 50 obese mothers matched for age, parity, ethnic origin, and educational level with 50 normal-weight mothers. Leptin, macronutrient human milk concentration, and milk volume were determined at 1 month in exclusively breastfed infants. Mother characteristics and infant growth were recorded. Human milk leptin concentration was higher in obese mothers than normal-weight mothers (4.8±2.7 vs. 2.5±1.5 ng.mL-1, p<0.001). No difference was observed between obese and normal-weight mothers in protein, lipid, carbohydrate content, and volume, nor in infant weight gain. Leptin concentration was higher in the milk of obese mothers than that of normal-weight mothers, but macronutrient concentration was not. It remains to be established whether the higher leptin content impacts on infant growth beyond the 1-month of the study period.

  18. Design of an optimum computer vision-based automatic abalone (Haliotis discus hannai) grading algorithm.

    PubMed

    Lee, Donggil; Lee, Kyounghoon; Kim, Seonghun; Yang, Yongsu

    2015-04-01

    An automatic abalone grading algorithm that estimates abalone weights on the basis of computer vision using 2D images is developed and tested. The algorithm overcomes the problems experienced by conventional abalone grading methods that utilize manual sorting and mechanical automatic grading. To design an optimal algorithm, a regression formula and R(2) value were investigated by performing a regression analysis for each of total length, body width, thickness, view area, and actual volume against abalone weights. The R(2) value between the actual volume and abalone weight was 0.999, showing a relatively high correlation. As a result, to easily estimate the actual volumes of abalones based on computer vision, the volumes were calculated under the assumption that abalone shapes are half-oblate ellipsoids, and a regression formula was derived to estimate the volumes of abalones through linear regression analysis between the calculated and actual volumes. The final automatic abalone grading algorithm is designed using the abalone volume estimation regression formula derived from test results, and the actual volumes and abalone weights regression formula. In the range of abalones weighting from 16.51 to 128.01 g, the results of evaluation of the performance of algorithm via cross-validation indicate root mean square and worst-case prediction errors of are 2.8 and ±8 g, respectively. © 2015 Institute of Food Technologists®

  19. Imaging gene and environmental effects on cerebellum in Attention-Deficit/Hyperactivity Disorder and typical development☆

    PubMed Central

    de Zeeuw, Patrick; van Belle, Janna; van Dijk, Sarai; Weusten, Juliette; Koeleman, Bobby; Janson, Esther; van Engeland, Herman; Durston, Sarah

    2012-01-01

    This study investigates the effects of XKR4, a recently identified candidate gene for Attention-Deficit/Hyperactivity Disorder (ADHD), birth weight, and their interaction on brain volume in ADHD. XKR4 is expressed in cerebellum and low birth weight has been associated both with changes in cerebellum and with ADHD, probably due to its relation with prenatal adversity. Anatomical MRI scans were acquired in 58 children with ADHD and 64 typically developing controls and processed to obtain volumes of cerebrum, cerebellum and gray and white matter in each structure. DNA was collected from saliva. Analyses including data on birth weight were conducted in a subset of 37 children with ADHD and 51 controls where these data were retrospectively collected using questionnaires. There was an interaction between genotype and birth weight for cerebellum gray matter volume (p = .020). The combination of homozygosity for the G-allele (the allele previously found to be overtransmitted in ADHD) and higher birth weight was associated with smaller volume. Furthermore, birth weight was positively associated with cerebellar white matter volume in controls, but not ADHD (interaction: p = .021). The interaction of genotype with birth weight affecting cerebellum gray matter is consistent with models that emphasize increased influence of genetic risk-factors in an otherwise favorable prenatal environment. The absence of an association between birth weight and cerebellum white matter volume in ADHD suggests that other genetic or environmental effects may be at play, unrelated to XKR4. These results underscore the importance of considering environmental effects in imaging genetics studies. PMID:24179763

  20. Micro CT based truth estimation of nodule volume

    NASA Astrophysics Data System (ADS)

    Kinnard, L. M.; Gavrielides, M. A.; Myers, K. J.; Zeng, R.; Whiting, B.; Lin-Gibson, S.; Petrick, N.

    2010-03-01

    With the advent of high-resolution CT, three-dimensional (3D) methods for nodule volumetry have been introduced, with the hope that such methods will be more accurate and consistent than currently used planar measures of size. However, the error associated with volume estimation methods still needs to be quantified. Volume estimation error is multi-faceted in the sense that there is variability associated with the patient, the software tool and the CT system. A primary goal of our current research efforts is to quantify the various sources of measurement error and, when possible, minimize their effects. In order to assess the bias of an estimate, the actual value, or "truth," must be known. In this work we investigate the reliability of micro CT to determine the "true" volume of synthetic nodules. The advantage of micro CT over other truthing methods is that it can provide both absolute volume and shape information in a single measurement. In the current study we compare micro CT volume truth to weight-density truth for spherical, elliptical, spiculated and lobulated nodules with diameters from 5 to 40 mm, and densities of -630 and +100 HU. The percent differences between micro CT and weight-density volume for -630 HU nodules range from [-21.7%, -0.6%] (mean= -11.9%) and the differences for +100 HU nodules range from [-0.9%, 3.0%] (mean=1.7%).

  1. Lung protection: an intervention for tidal volume reduction in a teaching intensive care unit

    PubMed Central

    Briva, Arturo; Gaiero, Cristina

    2016-01-01

    Objective To determine the effect of feedback and education regarding the use of predicted body weight to adjust tidal volume in a lung-protective mechanical ventilation strategy. Methods The study was performed from October 2014 to November 2015 (12 months) in a single university polyvalent intensive care unit. We developed a combined intervention (education and feedback), placing particular attention on the importance of adjusting tidal volumes to predicted body weight bedside. In parallel, predicted body weight was estimated from knee height and included in clinical charts. Results One hundred fifty-nine patients were included. Predicted body weight assessed by knee height instead of visual evaluation revealed that the delivered tidal volume was significantly higher than predicted. After the inclusion of predicted body weight, we observed a sustained reduction in delivered tidal volume from a mean (standard error) of 8.97 ± 0.32 to 7.49 ± 0.19mL/kg (p < 0.002). Furthermore, the protocol adherence was subsequently sustained for 12 months (delivered tidal volume 7.49 ± 0.54 versus 7.62 ± 0.20mL/kg; p = 0.103). Conclusion The lack of a reliable method to estimate the predicted body weight is a significant impairment for the application of a worldwide standard of care during mechanical ventilation. A combined intervention based on education and repeated feedbacks promoted sustained tidal volume education during the study period (12 months). PMID:27925055

  2. Gallstones and gallbladder cancer-volume and weight of gallstones are associated with gallbladder cancer: a case-control study.

    PubMed

    Roa, Iván; Ibacache, Gilda; Roa, Juan; Araya, Juan; de Aretxabala, Xabier; Muñoz, Sergio

    2006-06-15

    Gallstones are considered the most important risk factor for gallbladder cancer. To identify differences in the number, weight, volume, and density of gallstones associated with chronic cholecystitis (CC), gallbladder dysplasia (GD), and gallbladder cancer (GBC). A total of 125 cases were selected, of which 93 had gallstones associated with GBC and 31 had gallstones associated with GD. The controls were those with CC, matched by sex and age. The number, weight, volume, and density of these gallstones were examined in order to determine differences and relative cancer risk. Number: Multiple gallstones were present in over 76% of cases (GBC and GD) and controls (P = ns). The average number of multiple stones was 21 in GBC versus 14 in controls (P < 0.01). Weight: The average weight of the gallstones was 9.6 g in GBC versus 6.0 g in controls (P = 0.0004). The average weight in multiple stones over 10 g had strong association with GBC (P = 0.0006). Volume: The average volume was 11.7 and 6.48 ml in GBC and controls (P = 0.0002). Average volumes of 6, 8, and 10 ml had a relative cancer risk of 5, 7, and 11 times, respectively. Size: No differences were shown between GBC, GD, and controls. The volume of gallstones associated with other risk factors of GBC may be helpful in prioritizing cholecystectomies in symptomatic patients. Copyright 2006 Wiley-Liss, Inc.

  3. Chronic corticosterone affects brain weight, and mitochondrial, but not glial volume fraction in hippocampal area CA3.

    PubMed

    Coburn-Litvak, P S; Tata, D A; Gorby, H E; McCloskey, D P; Richardson, G; Anderson, B J

    2004-01-01

    Corticosterone (CORT), the predominant glucocorticoid in rodents, is known to damage hippocampal area CA3. Here we investigate how that damage is represented at the cellular and ultrastructural level of analyses. Rats were injected with CORT (26.8 mg/kg, s.c.) or vehicle for 56 days. Cell counts were estimated with the physical disector method. Glial and mitochondrial volume fractions were obtained from electron micrographs. The effectiveness of the CORT dose used was demonstrated in two ways. First, CORT significantly inhibited body weight gain relative to vehicles. Second, CORT significantly reduced adrenal gland, heart and gastrocnemius muscle weight. Both the adrenal and gastrocnemius muscle weight to body weight ratios were also significantly reduced. Although absolute brain weight was reduced, the brain to body weight ratio was higher in the CORT group relative to vehicles, suggesting that the brain is more resistant to the effects of CORT than many peripheral organs and muscles. Consistent with that interpretation, CORT did not alter CA3 cell density, cell layer volume, or apical dendritic neuropil volume. Likewise, CORT did not significantly alter glial volume fraction, but did reduce mitochondrial volume fraction. These findings highlight the need for ultrastructural analyses in addition to cellular level analyses before conclusions can be drawn about the damaging effects of prolonged CORT elevations. The relative reduction in mitochondria may indicate a reduction in bioenergetic capacity that, in turn, could render CA3 vulnerable to metabolic challenges.

  4. Non-Line of Sight-Combined Arms (NLOS-CA) Manpower, Personnel and Logistics Impact Analysis (LIA)

    DTIC Science & Technology

    1993-11-15

    total weight and volume to explosive weight have been used. These measure the size of the round relative to the killing power in the round. On this basis...the weapon system is powered up. (3) Alert Time is that time during which radios are operating, but the system is not powered up. For this analysis...TELEPHONE MANUA: SB-22/PT 1S U99185 UTILITY RECEPTACLE I V31211 TELEPHONE SET TA312 26 V•1788 POWER SUPPLY YE8 HYP-571TSEC 2I N32593 SHOP EQUIP AUTO

  5. Mod-5A Wind Turbine Generator Program Design Report. Volume 2: Conceptual and Preliminary Design, Book 1

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. There are four volumes. In Volume 2, book 1 the requirements and criteria for the design are presented. The conceptual design studies, which defined a baseline configuration and determined the weights, costs and sizes of each subsystem, are described. The development and optimization of the wind turbine generator are presented through the description of the ten intermediate configurations between the conceptual and final designs. Analyses of the system's load and dynamics are presented.

  6. Impact of surgeon volume on the morbidity and costs of radical cystectomy in the USA: a contemporary population-based analysis.

    PubMed

    Leow, Jeffrey J; Reese, Stephen; Trinh, Quoc-Dien; Bellmunt, Joaquim; Chung, Benjamin I; Kibel, Adam S; Chang, Steven L

    2015-05-01

    To evaluate the relationship between surgeon volume of radical cystectomy (RC) and postoperative morbidity, and to assess the economic burden of bladder cancer in the USA. We captured all patients who underwent RC (International Classification of Diseases, ninth revision, code 57.71) between 2003 and 2010, using a nationwide hospital discharge database. Patient, hospital and surgical characteristics were evaluated. The annual volume of RCs performed by the surgeons was divided into quintiles. Multivariable regression models were developed, adjusting for clustering and survey weighting, to evaluate the outcomes, including 90-day major complications (Clavien grade III-V) and direct patient costs. We adjusted for clustering and weighting to achieve a nationally representative analysis. The weighted cohort included 49,792 patients who underwent RC, with an overall 90-day major complication rate of 16.2%. Compared with surgeons performing one RC annually, surgeons performing ≥7 RCs each year had 45% lower odds of major complications (odds ratio [OR] 0.55; P < 0.001) and lower costs by $1690 (P = 0.02). Results were consistent when we analysed surgeon volume as a continuous variable and when we examined the surgeons with the highest volumes (≥28 cases annually), which showed markedly lower odds of major complications compared with the surgeons with the lowest volumes (OR 0.45, 95% CI 0.31-0.67; P < 0.001). Compared with patients who did not have any complications, those who had a major complication were associated with significantly higher 90-day median direct hospital costs ($43,965 vs $24,341; P < 0.001). We showed that there was an inverse relationship between surgeon volume and the development of postoperative 90-day major complication rates as well as direct hospital costs. Centralisation of RC to surgeons with higher volumes may reduce the development of postoperative major complications, thereby decreasing the burden of bladder cancer on the healthcare system. © 2014 The Authors. BJU International © 2014 BJU International.

  7. Weight and volume equations and tables for six upland hardwoods in southern Illinois.

    Treesearch

    David J. Polak; Donald Raisanen; Richard C. Schlesinger; Les Stortz

    1980-01-01

    This paper presents tables of total tree green weight, green weight to a 5 cm and a 10 cm top diameter, dry weight to both 5 cm and 10 cm top diameter, and green volume to a 5 cm and 10 cm top diameter for six upland hardwood species. Both metric and English unit tables are included.

  8. [Liver volume, intrahepatic fat and body weight in the course of a lifestyle interventional study: Analysis with quantitative MR-based methods].

    PubMed

    Bongers, M N; Stefan, N; Fritsche, A; Häring, H-U; Nikolaou, K; Schick, F; Machann, J

    2015-04-01

    The aim of this study was to investigate potential associations between changes in liver volume, the amount of intrahepatic lipids (IHL) and body weight during lifestyle interventions. In a prospective study 150 patients with an increased risk for developing type 2 diabetes mellitus were included who followed a caloric restriction diet for 6 months. In the retrospective analysis 18 women and 9 men (age range 22-71 years) with an average body mass index (BMI) of 32 kg/m(2) were enrolled. The liver volume was determined at the beginning and after 6 months by three-dimensional magnetic resonance imaging (3D-MRI, echo gradient, opposed-phase) and IHLs were quantified by volume-selective MR spectroscopy in single voxel stimulated echo acquisition mode (STEAM). Univariable and multivariable correlation analyses between changes of liver volume (Δliver volume), intrahepatic lipids (ΔIHL) and body weight (ΔBW) were performed. Univariable correlation analysis in the whole study cohort showed associations between ΔIHL and ΔBW (r = 0.69; p < 0.0001), ΔIHL and Δliver volume (r = 0.66; p = 0.0002) as well as ΔBW and Δliver volume (r = 0.5; p = 0.0073). Multivariable correlation analysis revealed that changes of liver volume are primarily determined by changes in IHL independent of changes in body weight (β = 0.0272; 95% CI: 0.0155-0.034; p < 0.0001). Changes of liver volume during lifestyle interventions are independent of changes of body weight primarily determined by changes of IHL. These results show the reversibility of augmented liver volume in steatosis if it is possible to reduce IHLs during lifestyle interventions.

  9. Birth weight and neonatal adiposity prediction using fractional limb volume obtained with 3D ultrasound.

    PubMed

    O'Connor, Clare; O'Higgins, Amy; Doolan, Anne; Segurado, Ricardo; Stuart, Bernard; Turner, Michael J; Kennelly, Máireád M

    2014-01-01

    The objective of this investigation was to study fetal thigh volume throughout gestation and explore its correlation with birth weight and neonatal body composition. This novel technique may improve birth weight prediction and lead to improved detection rates for fetal growth restriction. Fractional thigh volume (TVol) using 3D ultrasound, fetal biometry and soft tissue thickness were studied longitudinally in 42 mother-infant pairs. The percentages of neonatal body fat, fat mass and fat-free mass were determined using air displacement plethysmography. Correlation and linear regression analyses were performed. Linear regression analysis showed an association between TVol and birth weight. TVol at 33 weeks was also associated with neonatal fat-free mass. There was no correlation between TVol and neonatal fat mass. Abdominal circumference, estimated fetal weight (EFW) and EFW centile showed consistent correlations with birth weight. Thigh volume demonstrated an additional independent contribution to birth weight prediction when added to the EFW centile from the 38-week scan (p = 0.03). Fractional TVol performed at 33 weeks gestation is correlated with birth weight and neonatal lean body mass. This screening test may highlight those at risk of fetal growth restriction or macrosomia.

  10. The effects of low tidal ventilation on lung strain correlate with respiratory system compliance.

    PubMed

    Xie, Jianfeng; Jin, Fang; Pan, Chun; Liu, Songqiao; Liu, Ling; Xu, Jingyuan; Yang, Yi; Qiu, Haibo

    2017-02-03

    The effect of alterations in tidal volume on mortality of acute respiratory distress syndrome (ARDS) is determined by respiratory system compliance. We aimed to investigate the effects of different tidal volumes on lung strain in ARDS patients who had various levels of respiratory system compliance. Nineteen patients were divided into high (C high group) and low (C low group) respiratory system compliance groups based on their respiratory system compliance values. We defined compliance ≥0.6 ml/(cmH 2 O/kg) as C high and compliance <0.6 ml/(cmH 2 O/kg) as C low . End-expiratory lung volumes (EELV) at various tidal volumes were measured by nitrogen wash-in/washout. Lung strain was calculated as the ratio between tidal volume and EELV. The primary outcome was that lung strain is a function of tidal volume in patients with various levels of respiratory system compliance. The mean baseline EELV, strain and respiratory system compliance values were 1873 ml, 0.31 and 0.65 ml/(cmH 2 O/kg), respectively; differences in all of these parameters were statistically significant between the two groups. For all participants, a positive correlation was found between the respiratory system compliance and EELV (R = 0.488, p = 0.034). Driving pressure and strain increased together as the tidal volume increased from 6 ml/kg predicted body weight (PBW) to 12 ml/kg PBW. Compared to the C high ARDS patients, the driving pressure was significantly higher in the C low patients at each tidal volume. Similar effects of lung strain were found for tidal volumes of 6 and 8 ml/kg PBW. The "lung injury" limits for driving pressure and lung strain were much easier to exceed with increases in the tidal volume in C low patients. Respiratory system compliance affected the relationships between tidal volume and driving pressure and lung strain in ARDS patients. These results showed that increasing tidal volume induced lung injury more easily in patients with low respiratory system compliance. Clinicaltrials.gov identifier NCT01864668 , Registered 21 May 2013.

  11. Self-weight effect in the measurement of the volume of silicon spheres

    NASA Astrophysics Data System (ADS)

    Mari, D.; Massa, E.; Kuramoto, N.; Mana, G.

    2018-04-01

    The volume of 28Si spheres about 94 mm in diameter is an input datum for the determination of the Avogadro constant. We report a finite element analysis of the self-weight effect on the volume determination via optical interferometric measurements of the sphere diameters. The self-weight expansion or shrinkage of the equatorial diameters, which ranges from  -31 pm to  +180 pm, depends on the southern latitude of the supports.

  12. Synthesis and Structural Characterization of New Light Molecular Weight Inorganic Oxidizers and Related Derivatives. Volume: 2

    DTIC Science & Technology

    1993-02-01

    of the strong inductive effect of the five fluorine ligands attached to the tellurium atom. 34 It is prepared under anhydrous conditions according to...MOLECULAR WEIGHT INORGANIC OXIDIZERS AND RELATED DERIVATIVES. VOLUME: II Professor G. J. Schrobilgen McMaster University Department of Chemistry...C: F04611-91-K-0004 Molecular Weight Inorganic Oxidizers and Relative PE: 62302F SDerivatives: Volume II 1PR: 5730 6. AUTHOFR(S) TA: 0*( C

  13. Technology for Large Space Systems: A Bibliography with Indexes. Supplement 17

    DTIC Science & Technology

    1987-10-01

    reduce the total primary reflector weight by a factor Lewis Research Center, Cleveland, Ohio. of 3 to 4 over competing technologies. On-orbit thermal...aperture. Weight and volume estimates are consistent with a single Proceedings of the Twenty-first ;ntersociety Energy Conversion Shuttle launch, and are...Aeronautics and Space Administration fiscal year Station. B.G. 1987 budget is examined. The impact of the loss of the Challenger and its crew on the space

  14. Advances in Inertial Navigation Systems and Components

    DTIC Science & Technology

    1981-04-01

    directions: a. Improvement of the classical fringeshil’t reading through differential two- detector schemes and application of very low loss components...1969 29. Aronowitz, F., " Loss Lock-In in Ringlaser," J. Appi Physics 41, 130 (1970) 30. Malota, F , "Ringlaser and Ringinterferometer," Laser and...8217 . ] 4-9 TABLE I Iý0PPERHEAD RRS CHARACTERISTICS SUMMARY Weight of Jet: - 3.8 oz. Weight of Total Packagt: - 12.0 oz. Volume of Total Packagi?: - 10.5 in

  15. Airway driving pressure and lung stress in ARDS patients.

    PubMed

    Chiumello, Davide; Carlesso, Eleonora; Brioni, Matteo; Cressoni, Massimo

    2016-08-22

    Lung-protective ventilation strategy suggests the use of low tidal volume, depending on ideal body weight, and adequate levels of PEEP. However, reducing tidal volume according to ideal body weight does not always prevent overstress and overstrain. On the contrary, titrating mechanical ventilation on airway driving pressure, computed as airway pressure changes from PEEP to end-inspiratory plateau pressure, equivalent to the ratio between the tidal volume and compliance of respiratory system, should better reflect lung injury. However, possible changes in chest wall elastance could affect the reliability of airway driving pressure. The aim of this study was to evaluate if airway driving pressure could accurately predict lung stress (the pressure generated into the lung due to PEEP and tidal volume). One hundred and fifty ARDS patients were enrolled. At 5 and 15 cmH2O of PEEP, lung stress, driving pressure, lung and chest wall elastance were measured. The applied tidal volume (mL/kg of ideal body weight) was not related to lung gas volume (r (2) = 0.0005 p = 0.772). Patients were divided according to an airway driving pressure lower and equal/higher than 15 cmH2O (the lower and higher airway driving pressure groups). At both PEEP levels, the higher airway driving pressure group had a significantly higher lung stress, respiratory system and lung elastance compared to the lower airway driving pressure group. Airway driving pressure was significantly related to lung stress (r (2) = 0.581 p < 0.0001 and r (2) = 0.353 p < 0.0001 at 5 and 15 cmH2O of PEEP). For a lung stress of 24 and 26 cmH2O, the optimal cutoff value for the airway driving pressure were 15.0 cmH2O (ROC AUC 0.85, 95 % CI = 0.782-0.922); and 16.7 (ROC AUC 0.84, 95 % CI = 0.742-0.936). Airway driving pressure can detect lung overstress with an acceptable accuracy. However, further studies are needed to establish if these limits could be used for ventilator settings.

  16. Susceptibility to ventilator induced lung injury is increased in senescent rats

    PubMed Central

    2013-01-01

    Introduction The principal mechanisms of ventilator induced lung injury (VILI) have been investigated in numerous animal studies. However, prospective data on the effect of old age on VILI are limited. Under the hypothesis that susceptibility to VILI is increased in old age, we investigated the pulmonary and extrapulmonary effects of mechanical ventilation with high tidal volume (VT) in old compared to young adult animals. Interventions Old (19.1 ± 3.0 months) and young adult (4.4 ± 1.3 months) male Wistar rats were anesthetized and mechanically ventilated (positive end-expiratory pressure 5 cmH2O, fraction of inspired oxygen 0.4, respiratory rate 40/minute) with a tidal volume (VT) of either 8, 16 or 24 ml/kg for four hours. Respiratory and hemodynamic variables, including cardiac output, and markers of systemic inflammation were recorded throughout the ventilation period. Lung histology and wet-to-dry weight ratio, injury markers in lung lavage and respiratory system pressure-volume curves were assessed post mortem. Basic pulmonary characteristics were assessed in non-ventilated animals. Results Compared to young adult animals, high VT (24 ml/kg body weight) caused more lung injury in old animals as indicated by decreased oxygenation (arterial oxygen tension (PaO2): 208 ± 3 vs. 131 ± 20 mmHg; P <0.05), increased lung wet-to-dry-weight ratio (5.61 ± 0.29 vs. 7.52 ± 0.27; P <0.05), lung lavage protein (206 ± 52 mg/l vs. 1,432 ± 101; P <0.05) and cytokine (IL-6: 856 ± 448 vs. 3,283 ± 943 pg/ml; P <0.05) concentration. In addition, old animals ventilated with high VT had more systemic inflammation than young animals (IL-1β: 149 ± 44 vs. 272 ± 36 pg/ml; P <0.05 - young vs. old, respectively). Conclusions Ventilation with unphysiologically large tidal volumes is associated with more lung injury in old compared to young rats. Aggravated pulmonary and systemic inflammation is a key finding in old animals developing VILI. PMID:23710684

  17. Cosmological measure with volume averaging and the vacuum energy problem

    NASA Astrophysics Data System (ADS)

    Astashenok, Artyom V.; del Popolo, Antonino

    2012-04-01

    In this paper, we give a possible solution to the cosmological constant problem. It is shown that the traditional approach, based on volume weighting of probabilities, leads to an incoherent conclusion: the probability that a randomly chosen observer measures Λ = 0 is exactly equal to 1. Using an alternative, volume averaging measure, instead of volume weighting can explain why the cosmological constant is non-zero.

  18. Use of diffusion-weighted MRI to modify radiosurgery planning in brain metastases may reduce local recurrence.

    PubMed

    Zakaria, Rasheed; Pomschar, Andreas; Jenkinson, Michael D; Tonn, Jörg-Christian; Belka, Claus; Ertl-Wagner, Birgit; Niyazi, Maximilian

    2017-02-01

    Stereotactic radiosurgery (SRS) is an effective and well tolerated treatment for selected brain metastases; however, local recurrence still occurs. We investigated the use of diffusion weighted MRI (DWI) as an adjunct for SRS treatment planning in brain metastases. Seventeen consecutive patients undergoing complete surgical resection of a solitary brain metastasis underwent image analysis retrospectively. SRS treatment plans were generated based on standard 3D post-contrast T1-weighted sequences at 1.5T and then separately using apparent diffusion coefficient (ADC) maps in a blinded fashion. Control scans immediately post operation confirmed complete tumour resection. Treatment plans were compared to one another and with volume of local recurrence at progression quantitatively and qualitatively by calculating the conformity index (CI), the overlapping volume as a proportion of the total combined volume, where 1 = identical plans and 0 = no conformation whatsoever. Gross tumour volumes (GTVs) using ADC and post-contrast T1-weighted sequences were quantitatively the same (related samples Wilcoxon signed rank test = -0.45, p = 0.653) but showed differing conformations (CI 0.53, p < 0.001). The diffusion treatment volume (DTV) obtained by combining the two target volumes was significantly greater than the treatment volume based on post contrast T1-weighted MRI alone, both quantitatively (median 13.65 vs. 9.52 cm 3 , related samples Wilcoxon signed rank test p < 0.001) and qualitatively (CI 0.74, p = 0.001). This DTV covered a greater volume of subsequent tumour recurrence than the standard plan (median 3.53 cm 3 vs. 3.84 cm 3 , p = 0.002). ADC maps may be a useful tool in addition to the standard post-contrast T1-weighted sequence used for SRS planning.

  19. Higher Leptin but Not Human Milk Macronutrient Concentration Distinguishes Normal-Weight from Obese Mothers at 1-Month Postpartum

    PubMed Central

    Frasquet-Darrieux, Marine; Gaud, Marie-Agnès; Christin, Patricia; Boquien, Clair-Yves; Millet, Christine; Herviou, Manon; Darmaun, Dominique; Robins, Richard J.; Ingrand, Pierre; Hankard, Régis

    2016-01-01

    Introduction Exclusively breastfed infants born to obese mothers have previously been shown to gain less weight by 1-month postpartum than infants of normal-weight mothers. Our hypothesis is that human milk composition and volume may differ between obese and normal-weight mothers. Objective To compare human milk leptin, macronutrient concentration, and volume in obese and normal-weight mothers. Mother and infant characteristics were studied as secondary aims. Materials and Methods This cross-sectional observational study compared 50 obese mothers matched for age, parity, ethnic origin, and educational level with 50 normal-weight mothers. Leptin, macronutrient human milk concentration, and milk volume were determined at 1 month in exclusively breastfed infants. Mother characteristics and infant growth were recorded. Results Human milk leptin concentration was higher in obese mothers than normal-weight mothers (4.8±2.7 vs. 2.5±1.5 ng.mL-1, p<0.001). No difference was observed between obese and normal-weight mothers in protein, lipid, carbohydrate content, and volume, nor in infant weight gain. Conclusion Leptin concentration was higher in the milk of obese mothers than that of normal-weight mothers, but macronutrient concentration was not. It remains to be established whether the higher leptin content impacts on infant growth beyond the 1-month of the study period. PMID:28005966

  20. Development of a Rapid Cycling CO(sub 2) and H(sub 2)O Removal Sorbent

    NASA Technical Reports Server (NTRS)

    Paul, Heather; Alptekin, Goekhan; Cates, Matthew; Bernal, Casey; Dubovik, Margarita; Gershanovich, Yevgenia

    2007-01-01

    The National Aeronautics and Space Administration (NASA) planned future missions set stringent demands on the design of the Portable Life Support System (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the Extravehicular Mobility Unit (EMU) is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The carbon dioxide and humidity control unit in the existing PLSS design is relatively large, since it has to remove and store 8 hours worth of CO2. If the sorbent regeneration can be carried out during the extravehicular activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. The progress of regenerable CO2 and humidity control is leading us towards the use of a rapid cycling amine system. TDA Research, Inc. is developing compact, regenerable sorbent materials to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all carbon dioxide and humidity duration-limiting elements in the life support system. The material also has applications in other areas of space exploration such as the Orion spacecraft and other longer duration exploration missions requiring regenerable technologies. This paper summarizes the results of the sorbent development, testing, and evaluation efforts to date. The results of a preliminary system analysis are also included, showing the size and volume reductions for PLSS provided by the new system.

  1. Advances in gallium arsenide monolithic microwave integrated-circuit technology for space communications systems

    NASA Technical Reports Server (NTRS)

    Bhasin, K. B.; Connolly, D. J.

    1986-01-01

    Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. In this paper, current developments in GaAs MMIC technology are described, and the status and prospects of the technology are assessed.

  2. Satellite voice broadcase system study. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Horstein, M.

    1985-01-01

    The feasibility of providing Voice of America (VOA) broadcasts by satellite relay was investigated. Satellite voice broadcast systems are described for three different frequency bands: HF, FHV, and L-band. Geostationary satellite configurations are considered for both frequency bands. A system of subsynchronous, circular satellites with an orbit period of 8 hours was developed for the HF band. The VHF broadcasts are provided by a system of Molniya satellites. The satellite designs are limited in size and weight to the capability of the STS/Centaur launch vehicle combination. At L-band, only four geostationary satellites are needed to meet the requirements of the complete broadcast schedule. These satellites are comparable in size and weight to current satellites designed for the direct broadcast of video program material.

  3. A Volumetric Assessment Using Computed Tomography of Canine and First Molar Roots in Dogs of Varying Weight.

    PubMed

    Scherer, Ellen; Snyder, Christopher J; Malberg, Jessica; Rigby, Brittney; Hetzel, Scott; Waller, Ken

    2018-06-01

    Mandibular volume and tooth root volumes were shown to increase at different rates at locations containing the roots of the canine (C) and mesial and distal roots of the first molar (M1). Thirty-six dogs were included in this study. Data were generated using computed tomography at locations of the mandible involving the roots of the C and M1 teeth. Software was used to trace the external surface of the mandible, calculating the volume of the mandible at each location. Similar techniques were used to trace and calculate the volume of the C and M1 roots. Mandible volume, tooth root volume, and root percentage of mandible volume were analyzed and compared using the slopes of the best fit line. At the M1 mesial and distal roots, mandible volume ( P < .001) and root volume ( P < .001) were both noted to increase, with increasing weight at different rates. The rate of change in the root percentage by weight of M1 roots was not different ( P = .214). Each location demonstrated a different increasing rate of change for mandibular volume and increasing root volume. Results show that as patient's weight increases, the mandible and root volumes increase at different rates. Root percentage by volume at all three locations was noted to decrease by the same rate. Canine and M1 roots are proportionally larger than the supporting mandibular bone in smaller patients. Care should be taken to recommend periodontal disease prevention for owners of small dogs and consideration made when performing extractions or other surgery that may destabilize the mandible.

  4. A study of an orbital radar mapping mission to Venus. Volume 3: Parametric studies and subsystem comparisons

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Parametric studies and subsystem comparisons for the orbital radar mapping mission to planet Venus are presented. Launch vehicle requirements and primary orbiter propulsion system requirements are evaluated. The systems parametric analysis indicated that orbit size and orientation interrelated with almost all of the principal spacecraft systems and influenced significantly the definition of orbit insertion propulsion requirements, weight in orbit capability, radar system design, and mapping strategy.

  5. Laser power conversion system analysis, volume 1

    NASA Technical Reports Server (NTRS)

    Jones, W. S.; Morgan, L. L.; Forsyth, J. B.; Skratt, J. P.

    1979-01-01

    The orbit-to-orbit laser energy conversion system analysis established a mission model of satellites with various orbital parameters and average electrical power requirements ranging from 1 to 300 kW. The system analysis evaluated various conversion techniques, power system deployment parameters, power system electrical supplies and other critical supplies and other critical subsystems relative to various combinations of the mission model. The analysis show that the laser power system would not be competitive with current satellite power systems from weight, cost and development risk standpoints.

  6. How much energy is locked in the USA? Alternative metrics for characterising the magnitude of overweight and obesity derived from BRFSS 2010 data.

    PubMed

    Reidpath, Daniel D; Masood, Mohd; Allotey, Pascale

    2014-06-01

    Four metrics to characterise population overweight are described. Behavioural Risk Factors Surveillance System data were used to estimate the weight the US population needed to lose to achieve a BMI < 25. The metrics for population level overweight were total weight, total volume, total energy, and energy value. About 144 million people in the US need to lose 2.4 million metric tonnes. The volume of fat is 2.6 billion litres-1,038 Olympic size swimming pools. The energy in the fat would power 90,000 households for a year and is worth around 162 million dollars. Four confronting ways of talking about a national overweight and obesity are described. The value of the metrics remains to be tested.

  7. An engineered microbial platform for direct biofuel production from brown macroalgae.

    PubMed

    Wargacki, Adam J; Leonard, Effendi; Win, Maung Nyan; Regitsky, Drew D; Santos, Christine Nicole S; Kim, Peter B; Cooper, Susan R; Raisner, Ryan M; Herman, Asael; Sivitz, Alicia B; Lakshmanaswamy, Arun; Kashiyama, Yuki; Baker, David; Yoshikuni, Yasuo

    2012-01-20

    Prospecting macroalgae (seaweeds) as feedstocks for bioconversion into biofuels and commodity chemical compounds is limited primarily by the availability of tractable microorganisms that can metabolize alginate polysaccharides. Here, we present the discovery of a 36-kilo-base pair DNA fragment from Vibrio splendidus encoding enzymes for alginate transport and metabolism. The genomic integration of this ensemble, together with an engineered system for extracellular alginate depolymerization, generated a microbial platform that can simultaneously degrade, uptake, and metabolize alginate. When further engineered for ethanol synthesis, this platform enables bioethanol production directly from macroalgae via a consolidated process, achieving a titer of 4.7% volume/volume and a yield of 0.281 weight ethanol/weight dry macroalgae (equivalent to ~80% of the maximum theoretical yield from the sugar composition in macroalgae).

  8. Converting wood volume to biomass for pinyon and juniper. Forest Service research note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chojnacky, D.C.; Moisen, G.G.

    1993-03-01

    A technique was developed to convert pinyon-juniper volume equation predictions to weights. The method uses specific gravity and biomass conversion equations to obtain foliage weight and total wood weight of all stems, branches, and bark. Specific gravity data are given for several Arizona pinyon-juniper species. Biomass conversion equations are constructed from pinyon-juniper data collected in Nevada. Results provide an interim means of estimating pinyon-juniper aboveground biomass from available volume inventory data.

  9. 75 FR 47888 - IntelliDriveSM

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... activities). Environment/fuel use. Pavement conditions (e.g., snow or ice cover, surface roughness, pothole.../destination pair, by time period, weighted by trip volume. System Throughput is intended to quantify the total.... Pavement conditions such as snow or ice cover, slippery conditions, surface roughness, or pothole detection...

  10. Space shuttle main engine definition (phase B). Volume 5: Valves and interconnects. [for space shuttle

    NASA Technical Reports Server (NTRS)

    Schultz, D. F.

    1971-01-01

    The steady state thermodynamic cycle balance of the single preburner staged combustion engine, coupled with dynamic transient analyses, dictated in detail the location and requirements for each valve defined in this volume. Valve configuration selections were influenced by overall engine and vehicle system weight and failure mode determinations. Modulating valve actuators are external to the valve and are line replaceable. Development and satisfactory demonstration of a high pressure dynamic shaft seal has made this configuration practical. Pneumatic motor driven actuators that use engine pumped hydrogen gas as the working fluid are used. The helium control system is proposed as a module containing a cluster of solenoid actuated valves. The separable couplings and flanges are designed to assure minimum leakage with minimum coupling weight. The deflection of the seal surface in the flange is defined by finite element analysis that has been confirmed with test data. The seal design proposed has passed preliminary pressure cycling and thermal cycling tests.

  11. Subcortical and cortical structural central nervous system changes and attention processing deficits in preschool-aged children with prenatal methamphetamine and tobacco exposure.

    PubMed

    Derauf, Chris; Lester, Barry M; Neyzi, Nurunisa; Kekatpure, Minal; Gracia, Luis; Davis, James; Kallianpur, Kalpana; Efird, Jimmy T; Kosofsky, Barry

    2012-01-01

    To examine the independent contributions of prenatal methamphetamine exposure (PME) and prenatal tobacco exposure (PTE) on brain morphology among a sample of nonalcohol-exposed 3- to 5-year-old children followed prospectively since birth. The sample included 20 children with PME (19 with PTE) and 15 comparison children (7 with PTE), matched on race, birth weight, maternal education and type of insurance. Subcortical and cortical volumes and cortical thickness measures were derived through an automated segmentation procedure from T1-weighted structural magnetic resonance images obtained on unsedated children. Attention was assessed using the computerized Conners' Kiddie Continuous Performance Test Version 5 (K-CPT™ V.5). PME effects on subcortical and cortical brain volumes and cortical thickness were tested by general linear model with type III sum of squares, adjusting for PTE, prenatal marijuana exposure, age at time of scan, gender, handedness, pulse sequence and total intracranial volume (for volumetric outcomes). A similar analysis was done for PTE effects on subcortical and cortical brain volumes and thickness, adjusting for PME and the above covariates. Children with PME had significantly reduced caudate nucleus volumes and cortical thickness increases in perisylvian and orbital-frontal cortices. In contrast, children with PTE showed cortical thinning in perisylvian and lateral occipital cortices and volumetric increases in frontal regions and decreases in anterior cingulate. PME was positively related and caudate volume was inversely related to K-CPT reaction time by inter-stimulus interval, a measure of the ability to adjust to changing task demands, suggesting that children with PME may have subtle attentional deficits mediated by caudate volume reductions. Our results suggest that PME and PTE may have distinct differential cortical effects on the developing central nervous system. Additionally, PME may be associated with subtle deficits in attention mediated by caudate volume reductions. Copyright © 2012 S. Karger AG, Basel.

  12. Systems design study of the Pioneer Venus spacecraft. Appendices to volume 1, sections 8-11 (part 3 of 3). [power subsystem/cost tradeoffs for Venus probe

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Power subsystem cost/weight tradeoffs are discussed for the Venus probe spacecraft. The cost estimations of power subsystem units were based upon DSCS-2, DSP, and Pioneer 10 and 11 hardware design and development and manufacturing experience. Parts count and degree of modification of existing hardware were factored into the estimate of manufacturing and design and development costs. Cost data includes sufficient quantities of units to equip probe bus and orbiter versions. It was based on the orbiter complement of equipment, but the savings in fewer slices for the probe bus balance the cost of the different probe bus battery. The preferred systems for the Thor/Delta and for the Atlas/Centaur are discussed. The weights of the candidate designs were based upon slice or tray weights for functionally equivalent circuitry measured on existing hardware such as Pioneers 10 and 11, Intelsat 3, DSCS-2, or DSP programs. Battery weights were based on measured cell weight data adjusted for case weight or off-the-shelf battery weights. The solar array weight estimate was based upon recent hardware experience on DSCS-2 and DSP arrays.

  13. Multi-Channel, Constant-Current Power Source for Aircraft Applications

    DTIC Science & Technology

    2017-03-01

    Special considerations impacting this design were minimizing volume, maintaining system power quality, and providing electrical fault protection...applications. Electrical loads, such as lighting, de-icing heaters, and actuators may be operated from this compact power conversion unit. Because of the...nature of aircraft systems, two of the most important design considerations are the maintenance of electrical power quality and minimization of weight

  14. Space station propulsion-ECLSS interaction study

    NASA Technical Reports Server (NTRS)

    Brennan, Scott M.

    1986-01-01

    The benefits of the utilization of effluents of the Space Station Environmental Control and Life Support (ECLS) system are examined. Various ECLSS-propulsion system interaction options are evaluated and compared on the basis of weight, volume, and power requirements. Annual propulsive impulse to maintain station altitude during a complete solar cycle of eleven years and the effect on station resupply are considered.

  15. Airborne rotary air separator study

    NASA Technical Reports Server (NTRS)

    Acharya, A.; Gottzmann, C. F.; Nowobilski, J. J.

    1990-01-01

    Several air breathing propulsion concepts for future earth-to-orbit transport vehicles utilize air collection and enrichment, and subsequent storage of liquid oxygen for later use in the vehicle emission. Work performed during the 1960's established the feasibility of substantially reducing weight and volume of a distillation type air separator system by operating the distillation elements in high 'g' fields obtained by rotating the separator assembly. This contract studied the capability test and hydraulic behavior of a novel structured or ordered distillation packing in a rotating device using air and water. Pressure drop and flood points were measured for different air and water flow rates in gravitational fields of up to 700 g. Behavior of the packing follows the correlations previously derived from tests at normal gravity. The novel ordered packing can take the place of trays in a rotating air separation column with the promise of substantial reduction in pressure drop, volume, and system weight. The results obtained in the program are used to predict design and performance of rotary separators for air collection and enrichment systems of interest for past and present concepts of air breathing propulsion (single or two-stage to orbit) systems.

  16. 40 CFR 60.493 - Performance test and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equivalent or alternative method. The owner or operator shall determine from company records the volume of... estimate the volume of coating used at each facility by using the average dry weight of coating, number of... acceptable to the Administrator. (i) Calculate the volume-weighted average of the total mass of VOC per...

  17. Water activity and mobility in solutions of glycerol and small molecular weight sugars: Implication for cryo- and lyopreservation

    NASA Astrophysics Data System (ADS)

    He, Xiaoming; Fowler, Alex; Toner, Mehmet

    2006-10-01

    In this study, the free volume models, originally developed for large molecular weight polymer-solvent systems, were used to study the water activity and mobility in solutions of four small molecular weight cryo-/lyoprotectants, viz., glycerol, a monosaccharide (fructose), and two disaccharides (sucrose and trehalose). The free volume model parameters were determined by fitting the models to available experimental data using a nonlinear optimization procedure. It was found that free volume models could accurately predict the available experimental data, which suggests that the free volume models might be generally applicable to aqueous solutions of small molecular weight cryo-/lyoprotectants. Furthermore, several models for estimating the mutual diffusion coefficient were tested using available experimental data for aqueous solutions of glycerol and a better method to estimate the mutual diffusion coefficient was proposed. Free volume models were used to predict and analyze the water activity and mobility in solutions of four cryo-/lyoprotectants under conditions frequently encountered in cryo-/lyopreservation applications. It was found that the water mobility in the glassy state of the above four solutions is essentially negligible in the case of cryopreservation with storage temperature lower than -110°C. However, the water mobility in a glass at higher temperature (>-80°C) may be significant. As a result, a subcooling of up to 50°C may be necessary for the long-term cryo-/lyopreservation of biomaterials depending on the water content and the type of cryo-/lyoprotectants. It was further shown that trehalose might be the best of the four protectants studied for lyopreservation (water mass fraction ⩽0.1) when the storage temperature is above the room temperature. The results from this study might be useful for the development of more effective protocols for both cryopreservation and lyopreservation of living cells and other biomaterials.

  18. 40 CFR 59.406 - Compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... exception of low solids stains and low solids wood preservatives, determine the VOC content in grams of VOC...: VOC content = grams of VOC per liter of coating Ws = weight of volatiles, in grams Ww = weight of water, in grams Wec = weight of exempt compounds, in grams Vm = volume of coating, in liters Vw = volume...

  19. 40 CFR 59.406 - Compliance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... exception of low solids stains and low solids wood preservatives, determine the VOC content in grams of VOC...: VOC content = grams of VOC per liter of coating Ws = weight of volatiles, in grams Ww = weight of water, in grams Wec = weight of exempt compounds, in grams Vm = volume of coating, in liters Vw = volume...

  20. 40 CFR 59.406 - Compliance provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... exception of low solids stains and low solids wood preservatives, determine the VOC content in grams of VOC...: VOC content = grams of VOC per liter of coating Ws = weight of volatiles, in grams Ww = weight of water, in grams Wec = weight of exempt compounds, in grams Vm = volume of coating, in liters Vw = volume...

  1. 40 CFR 59.406 - Compliance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... exception of low solids stains and low solids wood preservatives, determine the VOC content in grams of VOC...: VOC content = grams of VOC per liter of coating Ws = weight of volatiles, in grams Ww = weight of water, in grams Wec = weight of exempt compounds, in grams Vm = volume of coating, in liters Vw = volume...

  2. 40 CFR 59.406 - Compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... exception of low solids stains and low solids wood preservatives, determine the VOC content in grams of VOC...: VOC content = grams of VOC per liter of coating Ws = weight of volatiles, in grams Ww = weight of water, in grams Wec = weight of exempt compounds, in grams Vm = volume of coating, in liters Vw = volume...

  3. Arterial stiffness and fetal growth in normotensive pregnancy.

    PubMed

    Elvan-Taspinar, Ayten; Franx, Arie; Bots, Michiel L; Koomans, Hein A; Bruinse, Hein W

    2005-03-01

    Normal pregnancy is characterized by a decrease in peripheral resistance and generalized vasodilation resulting in plasma volume expansion, which is associated with intrauterine growth. Stiffness of the arterial system may be a measure of the degree of plasma volume expansion. Pulse wave velocity (PWV), measured by applanation tonometry, is a validated approach to determine arterial stiffness. Pulse pressure (PP) is considered a surrogate measure for arterial stiffness. The aim of this study was to evaluate the association between arterial stiffness and fetal growth. In 50 normotensive pregnancies, carotid-femoral PWV was measured in the third trimester in 30 degrees lateral position. Blood pressure measurements were performed with conventional auscultatory sphygmomanometry. Birth weight centiles and weight centiles at the age of 6 months were recorded. Linear regression models were used for statistical analyses. There was a significant relationship in PWV with both birth weight centiles and catch-up growth after birth, independent of mean arterial pressure (MAP). An increase of 1 m/sec in PWV was associated with a decrease in birth weight centiles by 17.6% and a catch-up of 22.3% in weight centiles after birth. A stronger association was found for pulse pressure and birth weight centiles. An increase of 1 mm Hg was associated with a decrease in birth weight centiles by 1.8%. There was no association between MAP and birth weight centiles. In normotensive pregnancy arterial stiffness is associated with birth weight centile and catch-up growth after birth, independently from MAP. This suggests that arterial stiffness reflects maternal vascular adaptation to pregnancy better than blood pressure.

  4. System design of the Pioneer Venus spacecraft. Volume 7: Communication subsystem studies

    NASA Technical Reports Server (NTRS)

    Newlands, D. M.

    1973-01-01

    Communications subsystem tradeoffs were undertaken to establish a low cost and low weight design consistent with the mission requirements. Because of the weight constraint of the Thor/Delta launched configuration, minimum weight was emphasized in determining the Thor/Delta design. In contrast, because of the greatly relaxed weight constraint of the Atlas/Centaur launched configuration, minimum cost and off the shelf hardware were emphasized and the attendant weight penalities accepted. Communication subsystem hardware elements identified for study included probe and bus antennas (CM-6, CM-17), power amplifiers (CM-10), and the large probe transponder and small probe stable oscillator required for doppler tracking (CM-11, CM-16). In addition, particular hardware problems associated with the probe high temperature and high-g environment were investigated (CM-7).

  5. Study of thermal management for space platform applications

    NASA Technical Reports Server (NTRS)

    Oren, J. A.

    1980-01-01

    Techniques for the management of the thermal energy of large space platforms using many hundreds of kilowatts over a 10 year life span were evaluated. Concepts for heat rejection, heat transport within the vehicle, and interfacing were analyzed and compared. The heat rejection systems were parametrically weight optimized over conditions for heat pipe and pumped fluid approaches. Two approaches to achieve reliability were compared for: performance, weight, volume, projected area, reliability, cost, and operational characteristics. Technology needs are assessed and technology advancement recommendations are made.

  6. Prediction of stream volatilization coefficients

    USGS Publications Warehouse

    Rathbun, Ronald E.

    1990-01-01

    Equations are developed for predicting the liquid-film and gas-film reference-substance parameters for quantifying volatilization of organic solutes from streams. Molecular weight and molecular-diffusion coefficients of the solute are used as correlating parameters. Equations for predicting molecular-diffusion coefficients of organic solutes in water and air are developed, with molecular weight and molal volume as parameters. Mean absolute errors of prediction for diffusion coefficients in water are 9.97% for the molecular-weight equation, 6.45% for the molal-volume equation. The mean absolute error for the diffusion coefficient in air is 5.79% for the molal-volume equation. Molecular weight is not a satisfactory correlating parameter for diffusion in air because two equations are necessary to describe the values in the data set. The best predictive equation for the liquid-film reference-substance parameter has a mean absolute error of 5.74%, with molal volume as the correlating parameter. The best equation for the gas-film parameter has a mean absolute error of 7.80%, with molecular weight as the correlating parameter.

  7. Hydrogen Storage for Aircraft Applications Overview

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Kohout, Lisa (Technical Monitor)

    2002-01-01

    Advances in fuel cell technology have brought about their consideration as sources of power for aircraft. This power can be utilized to run aircraft systems or even provide propulsion power. One of the key obstacles to utilizing fuel cells on aircraft is the storage of hydrogen. An overview of the potential methods of hydrogen storage was compiled. This overview identifies various methods of hydrogen storage and points out their advantages and disadvantages relative to aircraft applications. Minimizing weight and volume are the key aspects to storing hydrogen within an aircraft. An analysis was performed to show how changes in certain parameters of a given storage system affect its mass and volume.

  8. The relationships between breast volume, breast dense volume and volumetric breast density with body mass index, body fat mass and ethnicity

    NASA Astrophysics Data System (ADS)

    Zakariyah, N.; Pathy, N. B.; Taib, N. A. M.; Rahmat, K.; Judy, C. W.; Fadzil, F.; Lau, S.; Ng, K. H.

    2016-03-01

    It has been shown that breast density and obesity are related to breast cancer risk. The aim of this study is to investigate the relationships of breast volume, breast dense volume and volumetric breast density (VBD) with body mass index (BMI) and body fat mass (BFM) for the three ethnic groups (Chinese, Malay and Indian) in Malaysia. We collected raw digital mammograms from 2450 women acquired on three digital mammography systems. The mammograms were analysed using Volpara software to obtain breast volume, breast dense volume and VBD. Body weight, BMI and BFM of the women were measured using a body composition analyser. Multivariable logistic regression was used to determine the independent predictors of increased overall breast volume, breast dense volume and VBD. Indians have highest breast volume and breast dense volume followed by Malays and Chinese. While Chinese are highest in VBD, followed by Malay and Indian. Multivariable analysis showed that increasing BMI and BFM were independent predictors of increased overall breast volume and dense volume. Moreover, BMI and BFM were independently and inversely related to VBD.

  9. Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques.

    PubMed

    Ferraz, C C; Gomes, N V; Gomes, B P; Zaia, A A; Teixeira, F B; Souza-Filho, F J

    2001-07-01

    To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R). Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established. Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant. Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.

  10. Nondestructive determination of radionuclides in lunar samples using a large low-background gamma-ray spectrometer and a novel application of least-squares fitting

    NASA Technical Reports Server (NTRS)

    Eldridge, J. S.; Okelly, G. D.; Northcutt, K. J.; Schonfeld, E.

    1972-01-01

    Dual-parameter gamma ray spectrometer systems with large volume Nal (Tl) crystals and low backgrounds were used for nondestructive determination of K, Th, U and cosmic ray produced radionuclides in 60 lunar samples. The total weight of samples measured with this system is 28 kg, and the individual sample weights varied from 2 to 2300 g. Samples from Apollo 11, 12, 14, 15 and 16 were measured. Operation of the spectrometers in the coincidence mode and analyzing single coincidence spectra permits the simultaneous determination of 8-10 radionuclides in each lunar sample.

  11. Reduced Volume Prototype Spacesuit Water Membrane Evaporator; A Next-Generation Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

    NASA Technical Reports Server (NTRS)

    Makinen, Janice V.; Anchondo, Ian; Bue, Grant C.; Campbell, Colin; Colunga, Aaron

    2013-01-01

    Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the reduced volume prototype (RVP) spacesuit water membrane evaporator (SWME). The RVP SWME is the third generation of hollow fiber SWME hardware. Like its predecessors, RVP SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and a more flight-like backpressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

  12. Apparatus for measurement of thermal conductivity of insulation systems subjected to extreme temperature differences

    NASA Technical Reports Server (NTRS)

    Dube, W. P.; Sparks, L. L.; Slifka, A. J.; Bitsy, R. M.

    1990-01-01

    Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.

  13. Apparatus for measurement of thermal conductivity of insulation systems subjected to extreme temperature differences

    NASA Astrophysics Data System (ADS)

    Dube, W. P.; Sparks, L. L.; Slifka, A. J.; Bitsy, R. M.

    Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.

  14. MR-guided conformal heating of canine prostate using interstitial applicators

    NASA Astrophysics Data System (ADS)

    Nau, William H.; Diederich, Chris J.; Ross, Anthony; Butts, R. K.; Rieke, Viola; Bouley, Donna; Gill, Harchi; Daniel, Bruce; Sommer, Graham

    2003-06-01

    MRI compatible, multi-element ultrasound applicators were fabricated using cylindrical piezoceramic transducers sectored to 180 degrees to provide angular directional heating. The applicators were designed to be inserted into standard 13 or 14 gage brachytherapy catheters integrated with water-cooling. Two applicators were inserted transperinealy into the posterior region of a canine prostate. Power output ranged from 5-15 W per element during the 15 minute heating period. Phase-sensitive gradient-recalled MR imaging was used to monitor the treatment in real-time on a 0.5 Tesla MRT system. Gadolinium-enhanced T1 weighted images and diffusion-weighted images were obtained to view the regions which had been ablated during the heating procedure. Upon euthanasia, the prostate was removed, axially sectioned, and stained with TTC to reveal any regions of remaining viable tissue. Results from this study indicated a large volume of ablated tissue within the prostate which was highly correlated to the regions in the T1-weighted and diffusion-weighted images which had decreased intensity, and to the 52C contour displayed in the images obtained during the treatment. This study demonstrates the ability to control thermal coagulation within a targeted tissue volume while protecting surrounding tissue from thermal damage.

  15. In the Age of Breast Augmentation, Breast Reconstruction Provides an Opportunity to Augment the Breast.

    PubMed

    Zimmerman, Amanda L; Tugertimur, Bugra; Smith, Paul D; Kumar, Ambuj; Dayicioglu, Deniz

    2017-01-01

    Augmentation mammoplasty remains the most common cosmetic surgery procedure performed. The objective of this article is to evaluate the impact of augmented volume of the reconstructed breast in patients that undergo nipple-sparing mastectomy and patients previously augmented who undergo mastectomy with tissue expander/implant-based reconstruction. Patients undergoing skin-sparing mastectomy, nipple-sparing mastectomy, and mastectomy after previous augmentation followed by tissue expander/implant-based reconstruction between June 2011 and April 2015 by 2 surgeons at the same institution were included. Retrospective chart review of the patients identified using these criteria was performed to record patient characteristics, complications, breast volume, implant volume, and percentage change in volume at the time of reconstruction. Percentage change of breast volume was calculated using the formula (implant breast weight)/(breast weight) for skin-sparing and nipple-sparing mastectomy patients and (final breast implant weight - [breast weight + augmentation breast implant weight])/([breast weight + augmentation breast implant]) for patients undergoing mastectomy following previous augmentation. A total of 293 patients were included in the study with 63 patients who underwent nipple-sparing mastectomy, 166 patients who underwent skin-sparing mastectomy, and 64 patients who underwent previous augmentation with subsequent mastectomy. Mean percentage change in breast volume was 66% in the nipple-sparing mastectomy group, 15% for the right breast and 18% for the left breast in the skin-sparing mastectomy group, and 81% for the right breast and 72% for the left breast in the mastectomy following previous augmentation group. Complication rate for nipple-sparing mastectomy was 27%, mastectomy following previous augmentation was 20.3%, and skin-sparing mastectomy group was 18.7%. Patients who undergo nipple-sparing mastectomy or mastectomy following previous augmentation have the ability to achieve greater volume in their reconstructed breast via tissue expander/implant-based reconstruction.

  16. Rectal cancer: assessment of complete response to preoperative combined radiation therapy with chemotherapy--conventional MR volumetry versus diffusion-weighted MR imaging.

    PubMed

    Curvo-Semedo, Luís; Lambregts, Doenja M J; Maas, Monique; Thywissen, Thomas; Mehsen, Rana T; Lammering, Guido; Beets, Geerard L; Caseiro-Alves, Filipe; Beets-Tan, Regina G H

    2011-09-01

    To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry. A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry. Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements. Post-CRT DW MR volumetry provided high diagnostic performance in assessing CR and was significantly more accurate than T2-weighted MR volumetry. Post-CRT DW MR was equally as accurate as volume measurements of both T2-weighted and DW MR. Pre-CRT volumetry and ADC were not reliable.

  17. The potential impact of new power system technology on the design of a manned space station

    NASA Technical Reports Server (NTRS)

    Fordyce, J. S.; Schwartz, H. J.

    1984-01-01

    Larger, more complex spacecraft of the future such as a manned Space Station will require electric power systems of 100 kW and more, orders of magnitude greater than the present state of the art. Power systems at this level will have a significant impact on the spacecraft design. Historically, long-lived spacecraft have relied on silicon solar cell arrays, a nickel-cadmium storage battery and operation at 28 V dc. These technologies lead to large array areas and heavy batteries for a Space Station application. This, in turn, presents orbit altitude maintenance, attitude control, energy management and launch weight and volume constraints. Size (area) and weight of such a power system can be reduced if new higher efficiency conversion and lighter weight storage technologies are used. Several promising technology options including concentrator solar photovoltaic arrays, solar thermal dynamic and ultimately nuclear dynamic systems to reduce area are discussed. Also, higher energy storage systems such as nickel-hydrogen and the regenerative fuel cell (RFC) and higher voltage power distribution which add system flexibility, simplicity and reduce weight are examined. Emphasis is placed on the attributes and development status of emerging technologies that are sufficiently developed so that they could be available for flight use in the early to mid 1990's.

  18. The potential impact of new power system technology on the design of a manned Space Station

    NASA Technical Reports Server (NTRS)

    Fordyce, J. S.; Schwartz, H. J.

    1984-01-01

    Larger, more complex spacecraft of the future such as a manned Space Station will require electric power systems of 100 kW and more, orders of magnitude greater than the present state of the art. Power systems at this level will have a significant impact on the spacecraft design. Historically, long-lived spacecraft have relied on silicon solar cell arrays, a nickel-cadmium storage battery and operation at 28 V dc. These technologies lead to large array areas and heavy batteries for a Space Station application. This, in turn, presents orbit altitude maintenance, attitude control, energy management and launch weight and volume constraints. Size (area) and weight of such a power system can be reduced if new higher efficiency conversion and lighter weight storage technologies are used. Several promising technology options including concentrator solar photovoltaic arrays, solar thermal dynamic and ultimately nuclear dynamic systems to reduce area are discussed. Also, higher energy storage systems such as nickel-hydrogen and the regenerative fuel cell (RFC) and higher voltage power distribution which add system flexibility, simplicity and reduce weight are examined. Emphasis placed on the attributes and development status of emerging technologies that are sufficiently developed so that they could be available for flight use in the early to mid 1990's.

  19. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    PubMed

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; p<0.001) and birth weight (correlation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  20. Bioimpedance, dry weight and blood pressure control: new methods and consequences.

    PubMed

    Kuhlmann, Martin K; Zhu, Fansan; Seibert, E; Levin, Nathan W

    2005-11-01

    Chronic overhydration contributes to the development of left ventricular hypertrophy and a high cardiovascular mortality in end-stage renal disease. Assessment of dry weight is highly dependent on clinical assessment. Bioimpedance technology offers the potential to quantify body fluid compartments and to facilitate dry weight prescription. This review covers recent innovative approaches to dry weight assessment using bioimpedance technology. Three different bioimpedance approaches to determine dry weight have been published. The normovolemic/hypervolemic slope method applies whole body multifrequency bioimpedance to assess predialysis total body extracellular fluid volume and compares the extracellular fluid volume/body weight relation at hypervolemia with the standard value in normovolemic individuals. The resistance-reactance graph method uses whole body single frequency bioimpedance for assessment of hydration state and nutritional status from height-adjusted resistance and reactance. The resulting resistance-reactance vector is set in relation to a distribution range in a normovolemic population. An alternative method uses segmental bioimpedance in the form of continuous intradialytic calf bioimpedance to record changes in calf extracellular volume during dialysis. Dry weight by this method is defined as the weight at which calf extracellular volume is not further reduced despite ongoing ultrafiltration. Although promising, none of these methods has gained much popularity, probably due to the difficulties in understanding bioimpedance and the lack of gold standard methods for dry weight determination. Bioimpedance will improve dry weight assessment, but further refinement of the methods as well as large-scale clinical studies to demonstrate the accuracy and the clinical value of objective dry weight determination are needed.

  1. Energy storage considerations for a robotic Mars surface sampler

    NASA Technical Reports Server (NTRS)

    Odonnell, Patricia M.; Cataldo, Robert L.; Gonzalez-Sanabria, Olga D.

    1988-01-01

    A Mars Rover capable of obtaining surface samples will need a power system for motive power and to power scientific instrumentation. Several different power systems are considered along with a discussion of the location options. The weight and volume advantages of the different systems are described for a particular power profile. The conclusions are that a Mars Rover Sample Return Mission and Extended Mission can be accomplished utilizing photovoltaics and electrochemical storage.

  2. Apical extrusion of debris and irrigants using ProTaper hand, M-two rotary and WaveOne single file reciprocating system: An ex vivo study.

    PubMed

    Singh, Abhishek; Arunagiri, Doraiswamy; Pushpa, Shankarappa; Sawhny, Asheesh; Misra, Abhinav; Khetan, Kirti

    2015-01-01

    The purpose of this ex vivo study was to evaluate and compare the weight of debris and volume of irrigant extruded apically from teeth using different preparation techniques. Thirty extracted human mandibular premolars with single canals and similar lengths were instrumented using hand ProTaper F2 (25, 0.08; Dentsply Maillefer, Ballaigues, Switzerland), M-two (25, 0.06; VDW, Munich, Germany) and WaveOne Primary (25, 0.08; Dentsply Maillefer, Ballaigues, Switzerland). Debris and irrigant extruded during instrumentation were collected into preweighed Eppendorf tubes. The volume of the irrigant was measured, and then the tubes were stored in an incubator at 70°C for 2 days. The Eppendorf tubes were weighed to obtain the final weight when the extruded debris was included. Three consecutive weights were obtained for each tube. Data were statistically analyzed by one-way analysis of variance and Student's t-test. There were no statistically significant differences among the groups. The WaveOne reciprocating system showed the maximum amount of apical extrusion of debris and irrigant among all the groups. The least amount of debris and irrigant was observed in ProTaper hand instrument (P > 0.05). All instrumentation techniques were associated with debris and irrigant extrusion.

  3. The 1985 Army Experience Survey: Tabular Descriptions of First-Term Attritees. Volume 1

    DTIC Science & Technology

    1986-01-01

    Assistance. Survey data were processed through survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The...270-271 048 R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY ...... .................. ... 272-273 049 E137 # TERMS OF... system - Weed out poor soldiers - Could not get promoted - Poor Day/bonuses/benefits - Other 15: Patriotism & defense - Patriotic fulfillment - Service

  4. Use of biotin targeted methotrexate–human serum albumin conjugated nanoparticles to enhance methotrexate antitumor efficacy

    PubMed Central

    Taheri, Azade; Dinarvand, Rassoul; Nouri, Faranak Salman; Khorramizadeh, Mohammad Reza; Borougeni, Atefeh Taheri; Mansoori, Pooria; Atyabi, Fatemeh

    2011-01-01

    Biotin molecules could be used as suitable targeting moieties in targeted drug delivery systems against tumors. To develop a biotin targeted drug delivery system, we employed human serum albumin (HSA) as a carrier. Methotrexate (MTX) molecules were conjugated to HSA. MTX-HSA nanoparticles (MTX-HSA NPs) were prepared from these conjugates by cross-linking the HSA molecules. Biotin molecules were then conjugated on the surface of MTX-HSA NPs. The anticancer efficacy of biotin targeted MTX-HSA NPs was evaluated in mice bearing 4T1 breast carcinoma. A single dose of biotin targeted MTX-HSA NPs showed stronger in vivo antitumor activity than non-targeted MTX-HSA NPs and free MTX. By 7 days after treatment, average tumor volume in the biotin targeted MTX-HSA NPs-treated group decreased to 17.6% of the initial tumor volume when the number of attached biotin molecules on MTX-HSA-NPs was the highest. Average tumor volume in non-targeted MTX-HSA NPs-treated mice grew rapidly and reached 250.7% of the initial tumor volume. Biotin targeted MTX-HSA NPs increased the survival of tumor-bearing mice to 47.5 ± 0.71 days and increased their life span up to 216.7%. Mice treated with biotin targeted MTX-HSA NPs showed slight body weight loss (8%) 21 days after treatment, whereas non-targeted MTX-HSA NPs treatment at the same dose caused a body weight loss of 27.05% ± 3.1%. PMID:21931482

  5. Bipolar Ag-Zn battery

    NASA Astrophysics Data System (ADS)

    Giltner, L. John

    1994-02-01

    The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

  6. Bipolar Ag-Zn battery

    NASA Technical Reports Server (NTRS)

    Giltner, L. John

    1994-01-01

    The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

  7. HASA: Hypersonic Aerospace Sizing Analysis for the Preliminary Design of Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Harloff, Gary J.; Berkowitz, Brian M.

    1988-01-01

    A review of the hypersonic literature indicated that a general weight and sizing analysis was not available for hypersonic orbital, transport, and fighter vehicles. The objective here is to develop such a method for the preliminary design of aerospace vehicles. This report describes the developed methodology and provides examples to illustrate the model, entitled the Hypersonic Aerospace Sizing Analysis (HASA). It can be used to predict the size and weight of hypersonic single-stage and two-stage-to-orbit vehicles and transports, and is also relevant for supersonic transports. HASA is a sizing analysis that determines vehicle length and volume, consistent with body, fuel, structural, and payload weights. The vehicle component weights are obtained from statistical equations for the body, wing, tail, thermal protection system, landing gear, thrust structure, engine, fuel tank, hydraulic system, avionics, electral system, equipment payload, and propellant. Sample size and weight predictions are given for the Space Shuttle orbiter and other proposed vehicles, including four hypersonic transports, a Mach 6 fighter, a supersonic transport (SST), a single-stage-to-orbit (SSTO) vehicle, a two-stage Space Shuttle with a booster and an orbiter, and two methane-fueled vehicles.

  8. Tutorial for Collecting and Processing Images of Composite Structures to Determine the Fiber Volume Fraction

    NASA Technical Reports Server (NTRS)

    Conklin, Lindsey

    2017-01-01

    Fiber-reinforced composite structures have become more common in aerospace components due to their light weight and structural efficiency. In general, the strength and stiffness of a composite structure are directly related to the fiber volume fraction, which is defined as the fraction of fiber volume to total volume of the composite. The most common method to measure the fiber volume fraction is acid digestion, which is a useful method when the total weight of the composite, the fiber weight, and the total weight can easily be obtained. However, acid digestion is a destructive test, so the material will no longer be available for additional characterization. Acid digestion can also be difficult to machine out specific components of a composite structure with complex geometries. These disadvantages of acid digestion led the author to develop a method to calculate the fiber volume fraction. The developed method uses optical microscopy to calculate the fiber area fraction based on images of the cross section of the composite. The fiber area fraction and fiber volume fraction are understood to be the same, based on the assumption that the shape and size of the fibers are consistent in the depth of the composite. This tutorial explains the developed method for optically determining fiber area fraction performed at NASA Langley Research Center.

  9. Limited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke.

    PubMed

    Schaefer, Pamela W; Souza, Leticia; Kamalian, Shervin; Hirsch, Joshua A; Yoo, Albert J; Kamalian, Shahmir; Gonzalez, R Gilberto; Lev, Michael H

    2015-02-01

    Diffusion-weighted imaging (DWI) can reliably identify critically ischemic tissue shortly after stroke onset. We tested whether thresholded computed tomographic cerebral blood flow (CT-CBF) and CT-cerebral blood volume (CT-CBV) maps are sufficiently accurate to substitute for DWI for estimating the critically ischemic tissue volume. Ischemic volumes of 55 patients with acute anterior circulation stroke were assessed on DWI by visual segmentation and on CT-CBF and CT-CBV with segmentation using 15% and 30% thresholds, respectively. The contrast:noise ratios of ischemic regions on the DWI and CT perfusion (CTP) images were measured. Correlation and Bland-Altman analyses were used to assess the reliability of CTP. Mean contrast:noise ratios for DWI, CT-CBF, and CT-CBV were 4.3, 0.9, and 0.4, respectively. CTP and DWI lesion volumes were highly correlated (R(2)=0.87 for CT-CBF; R(2)=0.83 for CT-CBV; P<0.001). Bland-Altman analyses revealed little systemic bias (-2.6 mL) but high measurement variability (95% confidence interval, ±56.7 mL) between mean CT-CBF and DWI lesion volumes, and systemic bias (-26 mL) and high measurement variability (95% confidence interval, ±64.0 mL) between mean CT-CBV and DWI lesion volumes. A simulated treatment study demonstrated that using CTP-CBF instead of DWI for detecting a statistically significant effect would require at least twice as many patients. The poor contrast:noise ratios of CT-CBV and CT-CBF compared with those of DWI result in large measurement error, making it problematic to substitute CTP for DWI in selecting individual acute stroke patients for treatment. CTP could be used for treatment studies of patient groups, but the number of patients needed to identify a significant effect is much higher than the number needed if DWI is used. © 2014 American Heart Association, Inc.

  10. Computer program to perform cost and weight analysis of transport aircraft. Volume 1: Summary

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A digital computer program for evaluating the weight and costs of advanced transport designs was developed. The resultant program, intended for use at the preliminary design level, incorporates both batch mode and interactive graphics run capability. The basis of the weight and cost estimation method developed is a unique way of predicting the physical design of each detail part of a vehicle structure at a time when only configuration concept drawings are available. In addition, the technique relies on methods to predict the precise manufacturing processes and the associated material required to produce each detail part. Weight data are generated in four areas of the program. Overall vehicle system weights are derived on a statistical basis as part of the vehicle sizing process. Theoretical weights, actual weights, and the weight of the raw material to be purchased are derived as part of the structural synthesis and part definition processes based on the computed part geometry.

  11. Legacy tree data: A national database of detailed tree measurements for volume, weight, and physical properties

    Treesearch

    P.J. Radtke; D.M. Walker; A.R. Weiskittel; J. Frank; J.W. Coulston; J.A. Westfall

    2015-01-01

    Forest mensurationists in the United States have expended considerable effort over the past century making detailed observations of trees’ dimensions. In recent decades efforts have focused increasingly on weights and physical properties. Work is underway to compile original measurements from past volume, taper, and weight or biomass studies for North American tree...

  12. Neural network-based systems for handprint OCR applications.

    PubMed

    Ganis, M D; Wilson, C L; Blue, J L

    1998-01-01

    Over the last five years or so, neural network (NN)-based approaches have been steadily gaining performance and popularity for a wide range of optical character recognition (OCR) problems, from isolated digit recognition to handprint recognition. We present an NN classification scheme based on an enhanced multilayer perceptron (MLP) and describe an end-to-end system for form-based handprint OCR applications designed by the National Institute of Standards and Technology (NIST) Visual Image Processing Group. The enhancements to the MLP are based on (i) neuron activations functions that reduce the occurrences of singular Jacobians; (ii) successive regularization to constrain the volume of the weight space; and (iii) Boltzmann pruning to constrain the dimension of the weight space. Performance characterization studies of NN systems evaluated at the first OCR systems conference and the NIST form-based handprint recognition system are also summarized.

  13. Automated egg grading system using computer vision: Investigation on weight measure versus shape parameters

    NASA Astrophysics Data System (ADS)

    Nasir, Ahmad Fakhri Ab; Suhaila Sabarudin, Siti; Majeed, Anwar P. P. Abdul; Ghani, Ahmad Shahrizan Abdul

    2018-04-01

    Chicken egg is a source of food of high demand by humans. Human operators cannot work perfectly and continuously when conducting egg grading. Instead of an egg grading system using weight measure, an automatic system for egg grading using computer vision (using egg shape parameter) can be used to improve the productivity of egg grading. However, early hypothesis has indicated that more number of egg classes will change when using egg shape parameter compared with using weight measure. This paper presents the comparison of egg classification by the two above-mentioned methods. Firstly, 120 images of chicken eggs of various grades (A–D) produced in Malaysia are captured. Then, the egg images are processed using image pre-processing techniques, such as image cropping, smoothing and segmentation. Thereafter, eight egg shape features, including area, major axis length, minor axis length, volume, diameter and perimeter, are extracted. Lastly, feature selection (information gain ratio) and feature extraction (principal component analysis) are performed using k-nearest neighbour classifier in the classification process. Two methods, namely, supervised learning (using weight measure as graded by egg supplier) and unsupervised learning (using egg shape parameters as graded by ourselves), are conducted to execute the experiment. Clustering results reveal many changes in egg classes after performing shape-based grading. On average, the best recognition results using shape-based grading label is 94.16% while using weight-based label is 44.17%. As conclusion, automated egg grading system using computer vision is better by implementing shape-based features since it uses image meanwhile the weight parameter is more suitable by using weight grading system.

  14. Distribution of volumes of individual glomeruli in kidneys at autopsy: association with age, nephron number, birth weight and body mass index.

    PubMed

    Hoy, W E; Hughson, M D; Zimanyi, M; Samuel, T; Douglas-Denton, R; Holden, L; Mott, S; Bertram, J F

    2010-11-01

    Glomerular hypertrophy occurs in a number of normal and pathological states. Glomerular volume in kidneys at autopsy is usually indirectly derived from estimates of total glomerular mass and nephron number, and provides only a single value per kidney, with no indication of the range of volumes of glomeruli within the kidney of any given subject. We review findings of the distribution of volumes of different glomeruli within subjects without kidney disease, and their correlations with age, nephron number, birth weight and body mass index (BMI). The study describes findings from autopsy kidneys of selected adult white males from the Southeast USA who had unexpected deaths, and who did not have renal scarring or renal disease. Total glomerular (nephron) number and total glomerular volume were estimated using the disector/fractionator combination, and mean glomerular volume (Vglom) was derived. The volumes of 30 individual glomeruli (IGV) in each subject were determined using the disector/Cavalieri method. IGV values were compared by categories of age, nephron number, birth weight and BMI. There was substantial variation in IGV within subjects. Older age, lower nephron number, lower birth weight and gross obesity were associated with higher mean IGV and with greater IGV heterogeneity. High Vglom and high IGVs were associated with more glomerulosclerosis. However, amongst the generally modest numbers of sclerosed glomeruli, the pattern was uniformly of ischemic collapse of the glomerular tuft. There was no detectable focal segmental glomerular tuft injury. In this series of people without overt renal disease, greater age, nephron deficit, lower birth weight and obesity were marked by glomerular enlargement and greater glomerular volume heterogeneity within individuals.

  15. Estimation of regional gas and tissue volumes of the lung in supine man using computed tomography.

    PubMed

    Denison, D M; Morgan, M D; Millar, A B

    1986-08-01

    This study was intended to discover how well computed tomography could recover the volume and weight of lung like foams in a body like shell, and then how well it could recover the volume and weight of the lungs in supine man. Model thoraces were made with various loaves of bread submerged in water. Computed tomography scans recovered the volume of the model lungs (true volume range 250-12,500 ml) within +0.2 (SD 68) ml and their weights (true range 72-3125 g) within +30 (78) g. Scans also recovered successive injections of 50 ml of water, within +/- 5 ml. Scans in 12 healthy supine men recovered their vital capacities, total lung capacities (TLC), and predicted tissue volumes with comparable accuracy. At total lung capacity the mean tissue volume of single lungs was 431 (64) ml and at residual volume (RV) it was 427 (63) ml. Tissue volume was then used to match inspiratory and expiratory slices and calculate regional ventilation. Throughout the mid 90% of lung the RV/TLC ratio was fairly constant--mean 21% (5%). New methods of presenting such regional data graphically and automatically are also described.

  16. Theoretical Evaluation of Electroactive Polymer Based Micropump Diaphragm for Air Flow Control

    NASA Technical Reports Server (NTRS)

    Xu, Tian-Bing; Su, Ji; Zhang, Qiming

    2004-01-01

    An electroactive polymer (EAP), high energy electron irradiated poly(vinylidene fluoride-trifluoroethylene) [P(VDFTrFE)] copolymer, based actuation micropump diaphragm (PAMPD) have been developed for air flow control. The displacement strokes and profiles as a function of amplifier and frequency of electric field have been characterized. The volume stroke rates (volume rate) as function of electric field, driving frequency have been theoretically evaluated, too. The PAMPD exhibits high volume rate. It is easily tuned with varying of either amplitude or frequency of the applied electric field. In addition, the performance of the diaphragms were modeled and the agreement between the modeling results and experimental data confirms that the response of the diaphragms follow the design parameters. The results demonstrated that the diaphragm can fit some future aerospace applications to replace the traditional complex mechanical systems, increase the control capability and reduce the weight of the future air dynamic control systems. KEYWORDS: Electroactive polymer (EAP), micropump, diaphragm, actuation, displacement, volume rate, pumping speed, clamping ratio.

  17. Design of a unidirectional composite momentum wheel rim

    NASA Astrophysics Data System (ADS)

    Shogrin, Bradley; Jones, William R., Jr.; Prahl, Joseph M.

    1995-05-01

    A preliminary study comparing twelve unidirectional-fiber composite systems to five metal materials conventionally used in momentum wheels is presented. Six different fibers are considered in the study: E-Glass, S-Glass, Boron, AS, T300, and Kevlar. Because of the possibility of high momentum requirements, and thus high stresses, only two matrix materials are considered: a high-modulus (HM) and a intermediate-modulus-high-strength (IMHS) matrix. Each of the six fibers are coupled with each of the two matrix materials. In an effort to optimize the composite system, each composite is considered while varying the fiber volume ratio from 0.0 to 0.7 in increments of 0.1. For fiber volume ratios above 0.2, all twelve unidirectional-fiber composite systems meet the study's requirements with higher factors of safety and less mass than the five conventional isotropic (metal) materials. For example, at a fiber volume ratio of 0.6, the Kevlar/IMHS composite system has a safety factor 4.5 times greater than that of a steel (maraging) system and an approximately 10 percent reduction in weight.

  18. A Novel Sensor System for Measuring Wheel Loads of Vehicles on Highways

    PubMed Central

    Zhang, Wenbin; Suo, Chunguang; Wang, Qi

    2008-01-01

    With the development of the highway transportation and business trade, vehicle Weigh-In-Motion (WIM) technology has become a key technology for measuring traffic loads. In this paper a novel WIM system based on monitoring of pavement strain responses in rigid pavement was investigated. In this WIM system multiple low cost, light weight, small volume and high accuracy embedded concrete strain sensors were used as WIM sensors to measure rigid pavement strain responses. In order to verify the feasibility of the method, a system prototype based on multiple sensors was designed and deployed on a relatively busy freeway. Field calibration and tests were performed with known two-axle truck wheel loads and the measurement errors were calculated based on the static weights measured with a static weighbridge. This enables the weights of other vehicles to be calculated from the calibration constant. Calibration and test results for individual sensors or three-sensor fusions are both provided. Repeatability, sources of error, and weight accuracy are discussed. Successful results showed that the proposed method was feasible and proven to have a high accuracy. Furthermore, a sample mean approach using multiple fused individual sensors could provide better performance compared to individual sensors. PMID:27873952

  19. Grey matter volume in adolescents with anorexia nervosa and associated eating disorder symptoms.

    PubMed

    Martin Monzon, Beatriz; Henderson, Luke A; Madden, Sloane; Macefield, Vaughan G; Touyz, Stephen; Kohn, Michael R; Clarke, Simon; Foroughi, Nasim; Hay, Phillipa

    2017-10-01

    Anorexia nervosa (AN) is a mental health disorder of complex aetiology. Previous neuroimaging studies have found consistent global reductions in global grey matter volume of underweight girls with AN; however, differences in regional grey matter volumes are less consistent. The aims of this study were to investigate grey matter regional volumes of adolescent girls with AN before and after weight recovery and the relationship of any changes with clinical characteristics. We collected high-resolution T1-weighted images from 26 underweight girls with AN before weight gain and 20 healthy control volunteers. Clinical features were assessed using the Eating Disorder Examination Questionnaire. AN subjects displayed reduced grey matter volumes in the insula, amygdala, prefrontal, hippocampal and cingulate cortices and the precuneus, relative to healthy controls. In a subset of 10 AN subjects who were followed after weight recovery, grey matter volumes increased to near-control levels in the orbito- and medial prefrontal, insular, left hippocampal and mid- and posterior cingulate cortices and precuneus. The recovery of the right anterior thalamus and the left orbitofrontal cortex was correlated with improvements in eating concerns and shape concerns, respectively. However, large parts of the anterior cingulate cortex, caudate nuclei and right hippocampus did not display any grey matter recovery following a short-term of treatment. These results show that in adolescents with AN, some brain regions display marked recovery in grey matter volume following weight recovery, whereas others do not, considering grey mater recovery possibly linked to symptom improvement. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  20. Yield table for hardwood bark residue

    Treesearch

    Jeffery L. Wartluft

    1974-01-01

    Bark residue weights are tabulated for eight species of hardwood sawlogs according to log volume by the Doyle, International 1/4-inch, and Scribner decimal C log rules. Factors are provided for converting from weight in pounds to volume in cubic yards.

  1. Weight, Volume, and Physical Properties of Major Hardwood Species in the Gulf and Atlantic Coastal Plains

    Treesearch

    Alexander Clark; Douglas R. Phillips; Douglas J. Frederick

    1985-01-01

    The weight, volume, and physical properties of trees 1 to 20 inches d.b.h. were determined for green ash, blackgum, red maple, sweetgum, water tupelo, yellow-poplar, hickory, laurel oak, water oak, and white oak in the Gulf and Atlantic Coastal Plains. Hard hardwood, soft hardwood, and individual species equations are presented for predicting green and dry weight...

  2. A computerized system to evaluate volumetric infusion pumps.

    PubMed

    Kobayashi, S; Ogata, T

    1992-01-01

    A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.

  3. Storage of H.sub.2 by absorption and/or mixture within a fluid medium

    DOEpatents

    Berry, Gene David; Aceves, Salvador Martin

    2007-03-20

    For the first time, a hydrogen storage method, apparatus and system having a fluid mixture is provided. At predetermined pressures and/or temperatures within a contained substantially fixed volume, the fluid mixture can store a high density of hydrogen molecules, wherein a predetermined phase of the fluid mixture is capable of being withdrawn from the substantially fixed volume for use as a vehicle fuel or energy storage having reduced and/or eliminated evaporative losses, especially where storage weight, vessel cost, vessel shape, safety, and energy efficiency are beneficial.

  4. Volume weighting the measure of the universe from classical slow-roll expansion

    NASA Astrophysics Data System (ADS)

    Sloan, David; Silk, Joseph

    2016-05-01

    One of the most frustrating issues in early universe cosmology centers on how to reconcile the vast choice of universes in string theory and in its most plausible high energy sibling, eternal inflation, which jointly generate the string landscape with the fine-tuned and hence relatively small number of universes that have undergone a large expansion and can accommodate observers and, in particular, galaxies. We show that such observations are highly favored for any system whereby physical parameters are distributed at a high energy scale, due to the conservation of the Liouville measure and the gauge nature of volume, asymptotically approaching a period of large isotropic expansion characterized by w =-1 . Our interpretation predicts that all observational probes for deviations from w =-1 in the foreseeable future are doomed to failure. The purpose of this paper is not to introduce a new measure for the multiverse, but rather to show how what is perhaps the most natural and well-known measure, volume weighting, arises as a consequence of the conservation of the Liouville measure on phase space during the classical slow-roll expansion.

  5. International Infantry and Joint Services Small Arms Systems Section Symposium, Exhibition and Firing Demonstration. Held in Atlantic City, NJ on 13-16 May 2002. Volume 2

    DTIC Science & Technology

    2002-05-13

    Atlantic Council NATO Army Armaments Group 30mm x 173 Ammunition Family by Allan Buckley & Pierre H. Freymond, Oerlikon Contraves Pyrotec AG Thursday, 16 May...actual weapon w/o adding weight • Compatible with LASER-activated battle simulators (MILES) 5.56mm FX - NDIA 2002.PPT (15.05.02) (11) FX® Marking...construction and design – Packaging inspection – Interfaces – Weight – Final protective finish – Endurance at ambient – Rough handling – Workmanship

  6. Near hybrid passenger vehicle development program, phase 1. Appendices C and D, Volume 2

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Results of tradeoff studies are presented in summary form. Various aspects of the overall vehicle design discussed include selection of the base vehicle, the battery pack configuration, structural modifications, occupant protection, vehicle dynamics, and aerodynamics. The drivetrain design and integration, power conditioning unit, battery subsystem, control system, environmental system are described. Specifications, weight breakdown, and energy consumption measures, and advanced technology components are included.

  7. Normal gray and white matter volume after weight restoration in adolescents with anorexia nervosa.

    PubMed

    Lázaro, Luisa; Andrés, Susana; Calvo, Anna; Cullell, Clàudia; Moreno, Elena; Plana, M Teresa; Falcón, Carles; Bargalló, Núria; Castro-Fornieles, Josefina

    2013-12-01

    The aim of this study was to determine whether treated, weight-stabilized adolescents with anorexia nervosa (AN) present brain volume differences in comparison with healthy controls. Thirty-five adolescents with weight-recovered AN and 17 healthy controls were assessed by means of psychopathology scales and magnetic resonance imaging. Axial three-dimensional T1-weighted images were obtained in a 1.5 Tesla scanner and analyzed using optimized voxel-based morphometry (VBM). There were no significant differences between controls and weight-stabilized AN patients with regard to global volumes of either gray or white brain matter, or in the regional VBM study. Differences were not significant between patients with psychopharmacological treatment and without, between those with amenorrhea and without, as well as between patients with restrictive versus purgative AN. The present findings reveal no global or regional gray or white matter abnormalities in this sample of adolescents following weight restoration. Copyright © 2013 Wiley Periodicals, Inc.

  8. Summary of green weights and volumes for five tree species in Michigan.

    Treesearch

    Sharon A. Winsauer; Helmuth M. Steinhilb

    1980-01-01

    Presents and summarizes the green weights and volumes of trees, boles and residue for sugar maple, white spruce, aspen, balsam fir and red pine in Northern Michigan. Equations, tables and graphs are included for each of the five species.

  9. An integrated compact airborne multispectral imaging system using embedded computer

    NASA Astrophysics Data System (ADS)

    Zhang, Yuedong; Wang, Li; Zhang, Xuguo

    2015-08-01

    An integrated compact airborne multispectral imaging system using embedded computer based control system was developed for small aircraft multispectral imaging application. The multispectral imaging system integrates CMOS camera, filter wheel with eight filters, two-axis stabilized platform, miniature POS (position and orientation system) and embedded computer. The embedded computer has excellent universality and expansibility, and has advantages in volume and weight for airborne platform, so it can meet the requirements of control system of the integrated airborne multispectral imaging system. The embedded computer controls the camera parameters setting, filter wheel and stabilized platform working, image and POS data acquisition, and stores the image and data. The airborne multispectral imaging system can connect peripheral device use the ports of the embedded computer, so the system operation and the stored image data management are easy. This airborne multispectral imaging system has advantages of small volume, multi-function, and good expansibility. The imaging experiment results show that this system has potential for multispectral remote sensing in applications such as resource investigation and environmental monitoring.

  10. Automotive manufacturing assessment system. Volume II: product schedules of engine/drivetrain combinations. Final report Jun 77-Aug 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, T. Jr; Cunningham, A.R.; Iannelli, D.A.

    Volume II is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of industry's capability to produce fuel efficient vehicles. Engine/driveline changes are the second most important contribution to fuel economy (weight reduction being the first) and are of major importance towards meeting emission standards. Through extensive synthesis of vehicle specifications and other data, chronological presentations were developed to illustrate engines and transmissions in production, engine/transmission and model/engine combinations, and automatic vs. manual transmission availability.more » Also shown are the progression of engine/driveline changes from 1975 through 1978; the correlation of these changes with new vehicle introductions; the restrictions on available drive-train options due to emission requirements; and technological improvements including dieselization, fuel metering, lock-up torque converters, and front-wheel-drive.« less

  11. Feasibility of mining lunar resources for earth use: Circa 2000 AD. Volume 2: Technical discussion

    NASA Technical Reports Server (NTRS)

    Nishioka, K.; Arno, R. D.; Alexander, A. D.; Slye, R. E.

    1973-01-01

    The technologies and systems required to establish the mining base, mine, refine, and return lunar resources to earth are discussed. Gross equipment requirements, their weights and costs are estimated and documented. The operational requirements are analyzed and tabulated. Diagrams of equipment and processing facilities are provided.

  12. Comprehensive Outlook for Managed Pines Using Simulated Treatment Experiments-Planted Loblolly Pine (COMPUTE_P-LOB): A User's Guide

    Treesearch

    R.B. Ferguson; V. Clark Baldwin

    1987-01-01

    Complete instructions for user operation of COMPUTE_P-LOB to include detailed examples of computer input and output, of a growth and yield prediction system providing volume and weight yields in stand and stock table format.A complete program listing is provided.

  13. Metric Education in Mathematics Methods Classes.

    ERIC Educational Resources Information Center

    Trent, John H.

    A pre-test on knowledge of the metric system was administered to elementary mathematics methods classes at the University of Nevada at the beginning of the 1975 Spring Semester. A one-hour lesson was prepared and taught regarding metric length, weight, volume, and temperature. At the end of the semester the original test was given as the…

  14. The Ninevah Mission: A design summary for an unmanned mission to Venus, volume 1

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The design summary for an unmanned mission to the planet Venus, with code name Ninevah, is presented. The design includes a Hohmann transfer trajectory analysis, propulsion trade study, an overview of the communication and instrumentation systems, power requirements, probe and lander analysis, and a weight and cost analysis.

  15. A High-efficiency, Small, Solid-state Laser for Pyrotechnic Ignition

    NASA Technical Reports Server (NTRS)

    Yang, L. C.; Menichelli, V. J.

    1973-01-01

    A completely self-contained, small, neodymium laser has been designed and demonstrated for use in a pyrotechnic ignition system. A nominal 16 J of laser energy (1.06 micron wavelength, 1-ms duration) was achieved in a rectangular 10.5-X 15.1-X 25.4-cm package weighting 5.14 kg. This high energy-to-weight ratio is encouraging for laser applications in which specific energy efficiency (energy per unit weight or volume) is important. The laser design concepts are described, and some results on pyrotechnic ignition are given. Some details on a laser currently under construction, which will be 1/8 the size of the above laser, are included.

  16. Activation energy-activation volume master plots for ion transport behavior in polymer electrolytes and supercooled molten salts.

    PubMed

    Ingram, Malcolm D; Imrie, Corrie T; Stoeva, Zlatka; Pas, Steven J; Funke, Klaus; Chandler, Howard W

    2005-09-08

    We demonstrate the use of activation energy versus activation volume "master plots" to explore ion transport in typical fragile glass forming systems exhibiting non-Arrhenius behavior. These systems include solvent-free salt complexes in poly(ethylene oxide) (PEO) and low molecular weight poly(propylene oxide) (PPO) and molten 2Ca(NO3)2.3KNO3 (CKN). Plots showing variations in apparent activation energy EA versus apparent activation volume VA are straight lines with slopes given by M = DeltaEA/DeltaVA. A simple ion transport mechanism is described where the rate determining step involves a dilatation (expressed as VA) around microscopic cavities and a corresponding work of expansion (EA). The slopes of the master plots M are equated to internal elastic moduli, which vary from 1.1 GPa for liquid PPO to 5.0 GPa for molten CKN on account of differing intermolecular forces in these materials.

  17. Optimization of a Hot Structure Aeroshell and Nose Cap for Mars Atmospheric Entry

    NASA Technical Reports Server (NTRS)

    Langston, Sarah L.; Lang, Christapher G.; Samareh, Jamshid A.; Daryabeigi, Kamran

    2016-01-01

    The National Aeronautics and Space Administration (NASA) is preparing to send humans beyond Low Earth Orbit and eventually to the surface of Mars. As part of the Evolvable Mars Campaign, different vehicle configurations are being designed and considered for delivering large payloads to the surface of Mars. Weight and packing volume are driving factors in the vehicle design, and the thermal protection system (TPS) for planetary entry is a technology area which can offer potential weight and volume savings. The feasibility and potential benefits of a ceramic matrix composite hot structure concept for different vehicle configurations are explored in this paper, including the nose cap for a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) and an aeroshell for a mid lift-to-drag (Mid L/D) concept. The TPS of a planetary entry vehicle is a critical component required to survive the severe aerodynamic heating environment during atmospheric en- try. The current state-of-the-art is an ablative material to protect the vehicle from the heat load. The ablator is bonded to an underlying structure, which carries the mechanical loads associated with entry. The alternative hot structure design utilizes an advanced carbon-carbon material system on the outer surface of the vehicle, which is exposed to the severe heating and acts as a load carrying structure. The preliminary design using the hot structure concept and the ablative concept is determined for the spherical nose cap of the HIAD entry vehicle and the aeroshell of the Mid L/D entry vehicle. The results of the study indicate that the use of hot structures for both vehicle concepts leads to a feasible design with potential weight and volume savings benefits over current state-of-the-art TPS technology that could enable future missions.

  18. Catalytic distillation water recovery subsystem

    NASA Technical Reports Server (NTRS)

    Budininkas, P.; Rasouli, F.

    1985-01-01

    An integrated engineering breadboard subsystem for the recovery of potable water from untreated urine based on the vapor phase catalytic ammonia removal was designed, fabricated and tested. Unlike other evaporative methods, this process catalytically oxidizes ammonia and volatile hydrocarbons vaporizing with water to innocuous products; therefore, no pretreatment of urine is required. Since the subsystem is fabricated from commercially available components, its volume, weight and power requirements are not optimized; however, it is suitable for zero-g operation. The testing program consists of parametric tests, one month of daily tests and a continuous test of 168 hours duration. The recovered water is clear, odorless, low in ammonia and organic carbon, and requires only an adjustment of its pH to meet potable water standards. The obtained data indicate that the vapor phase catalytic ammonia removal process, if further developed, would also be competitive with other water recovery systems in weight, volume and power requirements.

  19. Weight and volume variation in truckloads of logs hauled in the central Appalachians

    Treesearch

    Floyd G. Timson

    1974-01-01

    Variation in volume and weight was found among loaded log trucks even when such factors as truck type, logging job, and driver influence were eliminated. A load range of 10,000 pounds or 1,000 board feet was commonplace for the same truck, driver, and cutting site. Differences in log size, shape, weight, and species caused a major share of this variation. Yet,...

  20. 46 CFR 160.176-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... weight and displacement values prescribed in Tables 160.047-4(c)(2) and § 160.047-(4)(c)(4), each front insert must have a weight of kapok of at least 8.25 oz. and a volume displacement of 9.0 ±0.25 lb., and the back insert must have a weight of kapok of at least 5.5 oz. and a volume displacement of 6.0 ±0.25...

  1. 46 CFR 160.176-3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... weight and displacement values prescribed in Tables 160.047-4(c)(2) and § 160.047-(4)(c)(4), each front insert must have a weight of kapok of at least 8.25 oz. and a volume displacement of 9.0 ±0.25 lb., and the back insert must have a weight of kapok of at least 5.5 oz. and a volume displacement of 6.0 ±0.25...

  2. 46 CFR 160.176-3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... weight and displacement values prescribed in Tables 160.047-4(c)(2) and § 160.047-(4)(c)(4), each front insert must have a weight of kapok of at least 8.25 oz. and a volume displacement of 9.0 ±0.25 lb., and the back insert must have a weight of kapok of at least 5.5 oz. and a volume displacement of 6.0 ±0.25...

  3. 46 CFR 160.176-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... weight and displacement values prescribed in Tables 160.047-4(c)(2) and § 160.047-(4)(c)(4), each front insert must have a weight of kapok of at least 8.25 oz. and a volume displacement of 9.0 ±0.25 lb., and the back insert must have a weight of kapok of at least 5.5 oz. and a volume displacement of 6.0 ±0.25...

  4. Weight-Volume relationships of Aspen and Winter-Cut Black Spruce Pulpwood in Northern Minnesota

    Treesearch

    David C. Lothner; Richard M. Marden; Edwin Kallio

    1974-01-01

    Seasonal weight-volume relationships were determined for rough (bark on) aspen and black spruce 100-inch pulpwood that was delivered withing 1 week after cutting in northern Minnesota during 1971-72. For aspen, the weight of wood and bark per cubic foot of wood averaged 56 pounds in the winter and 61 pounds in the summer. This relationshipfor winter-cut black spruce...

  5. Space shuttle orbiter trimmed center-of-gravity extension study. Volume 3: Impact of retrofits for center-of-gravity extension on orbiter thermal-protection system

    NASA Technical Reports Server (NTRS)

    Dunavant, J. C.

    1979-01-01

    Heat transfer studies were conducted at Mach 10.3 on space shuttle orbiter models with the S-2 fillet and C-4 canard retrofit moldlines which were generated in aerodynamic and system design studies to increase the allowable c.g. range of the orbiter. Areas of orbiter most strongly affected were the sides where a shear layer which separated along the wing leading edge impinged. Analytical studies of the heating effect on the thermal-protection system were made which indicated that scar weight on the orbiter sides due to allowances for retrofits of the S-2 fillet and C-4 canard is small (less than about 90 kg (200 lbs) in comparison to the total weight of the retrofit).

  6. Characterization of Volume F Trash from Four Recent STS Missions: Weights, Categorization, Water Content

    NASA Technical Reports Server (NTRS)

    Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.

    2011-01-01

    The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under consideration and active technology development. Potential fates for space-generated solid wastes are: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. Recycling might be important for partial or full closure scenarios because of the prohibitive costs associated with resupply of consumable materials. For this study, we determined the composition of trash returned from four recent STS missions. The trash material was 'Volume F' trash and other trash, in large zip-lock bags, that accompanied the Volume F trash. This is the first of two submitted papers on these wastes. This one will cover trash content, weight and water content. The other will report on the microbial Characterization of this trash. STS trash was usually made available within 2 days of landing at KSC. The Volume F bag was weighed, opened and the contents were catalogued and placed into one of the following categories: food waste (and containers), drink containers, personal hygiene items - including EVA maximum absorbent garments (MAGs)and Elbow packs (daily toilet wipes, etc), paper, and packaging materials - plastic firm and duct tape. Trash generation rates for the four STS missions: Total wet trash was 0.602 plus or minus 0.089 kg(sub wet) crew(sup -1) d(sup -1) containing about 25% water at 0.154 plus or minus 0.030 kg(sub water) crew(sup -1) d(sup -1) (avg plus or minus stdev). Cataloguing by category: personal hygiene wastes accounted for 50% of the total trash and 69% of the total water for the four missions; drink items were 16% of total weight and 16% water; food wastes were 22% of total weight and 15% of the water; office waste and plastic film were 2% and 11% of the total waste and did not contain any water. The results can be used by NASA to determine requirements and criteria for Waste Management Systems on future missions.

  7. Substantia Nigra Volume Loss Before Basal Forebrain Degeneration in Early Parkinson Disease

    PubMed Central

    Ziegler, David A.; Wonderlick, Julien S.; Ashourian, Paymon; Hansen, Leslie A.; Young, Jeremy C.; Murphy, Alex J.; Koppuzha, Cecily K.; Growdon, John H.; Corkin, Suzanne

    2017-01-01

    Objective To test the hypothesis that degeneration of the substantia nigra pars compacta (SNc) precedes that of the cholinergic basal forebrain (BF) in Parkinson disease (PD) using new multispectral structural magnetic resonance (MR) imaging tools to measure the volumes of the SNc and BF. Design Matched case-control study. Setting The Athinoula A. Martinos Imaging Center at the McGovern Institute for Brain Research, Massachusetts Institute of Technology (MIT), and the Massachusetts General Hospital/MIT Morris Udall Center of Excellence in Parkinson Disease Research. Patients Participants included 29 patients with PD (Hoehn and Yahr [H&Y] stages 1–3) and 27 matched healthy control subjects. Main Outcome Measures We acquired multiecho T1-weighted, multiecho proton density, T2-weighted, and T2-weighted fluid-attenuated inversion recovery (FLAIR) sequences from each participant. For the SNc, we created a weighted mean of the multiple echoes, yielding a single volume with a high ratio of contrast to noise. We visualized the BF using T2-weighted FLAIR images. For each participant, we manually labeled the 2 structures and calculated their volumes. Results Relative to the controls, 13 patients with H&Y stage 1 PD had significantly decreased SNc volumes. Sixteen patients with H&Y stage 2 or 3 PD showed little additional volume loss. In contrast, the BF volume loss occurred later in the disease, with a significant decrease apparent in patients having H&Y stage 2 or 3 PD compared with the controls and the patients having H&Y stage 1 PD. The latter group did not differ significantly from the controls. Conclusion Our results support the proposed neuropathological trajectory in PD and establish novel multispectral methods as MR imaging biomarkers for tracking the degeneration of the SNc and BF. PMID:23183921

  8. Understanding PSA and its derivatives in prediction of tumor volume: Addressing health disparities in prostate cancer risk stratification.

    PubMed

    Chinea, Felix M; Lyapichev, Kirill; Epstein, Jonathan I; Kwon, Deukwoo; Smith, Paul Taylor; Pollack, Alan; Cote, Richard J; Kryvenko, Oleksandr N

    2017-03-28

    To address health disparities in risk stratification of U.S. Hispanic/Latino men by characterizing influences of prostate weight, body mass index, and race/ethnicity on the correlation of PSA derivatives with Gleason score 6 (Grade Group 1) tumor volume in a diverse cohort. Using published PSA density and PSA mass density cutoff values, men with higher body mass indices and prostate weights were less likely to have a tumor volume <0.5 cm3. Variability across race/ethnicity was found in the univariable analysis for all PSA derivatives when predicting for tumor volume. In receiver operator characteristic analysis, area under the curve values for all PSA derivatives varied across race/ethnicity with lower optimal cutoff values for Hispanic/Latino (PSA=2.79, PSA density=0.06, PSA mass=0.37, PSA mass density=0.011) and Non-Hispanic Black (PSA=3.75, PSA density=0.07, PSA mass=0.46, PSA mass density=0.008) compared to Non-Hispanic White men (PSA=4.20, PSA density=0.11 PSA mass=0.53, PSA mass density=0.014). We retrospectively analyzed 589 patients with low-risk prostate cancer at radical prostatectomy. Pre-operative PSA, patient height, body weight, and prostate weight were used to calculate all PSA derivatives. Receiver operating characteristic curves were constructed for each PSA derivative per racial/ethnic group to establish optimal cutoff values predicting for tumor volume ≥0.5 cm3. Increasing prostate weight and body mass index negatively influence PSA derivatives for predicting tumor volume. PSA derivatives' ability to predict tumor volume varies significantly across race/ethnicity. Hispanic/Latino and Non-Hispanic Black men have lower optimal cutoff values for all PSA derivatives, which may impact risk assessment for prostate cancer.

  9. Randomized Double-Blind Placebo-Controlled Trial of Bevacizumab Therapy for Radiation Necrosis of the Central Nervous System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levin, Victor A., E-mail: vlevin49@comcast.ne; Bidaut, Luc; Hou, Ping

    Purpose: To conduct a controlled trial of bevacizumab for the treatment of symptomatic radiation necrosis of the brain. Methods and Materials: A total of 14 patients were entered into a placebo-controlled randomized double-blind study of bevacizumab for the treatment of central nervous system radiation necrosis. All patients were required to have radiographic or biopsy proof of central nervous system radiation necrosis and progressive neurologic symptoms or signs. Eligible patients had undergone irradiation for head-and-neck carcinoma, meningioma, or low- to mid-grade glioma. Patients were randomized to receive intravenous saline or bevacizumab at 3-week intervals. The magnetic resonance imaging findings 3 weeksmore » after the second treatment and clinical signs and symptoms defined the response or progression. Results: The volumes of necrosis estimated on T{sub 2}-weighted fluid-attenuated inversion recovery and T{sub 1}-weighted gadolinium-enhanced magnetic resonance imaging scans demonstrated that although no patient receiving placebo responded (0 of 7), all bevacizumab-treated patients did so (5 of 5 randomized and 7 of 7 crossover) with decreases in T{sub 2}-weighted fluid-attenuated inversion recovery and T{sub 1}-weighted gadolinium-enhanced volumes and a decrease in endothelial transfer constant. All bevacizumab-treated patients-and none of the placebo-treated patients-showed improvement in neurologic symptoms or signs. At a median of 10 months after the last dose of bevacizumab in patients receiving all four study doses, only 2 patients had experienced a recurrence of magnetic resonance imaging changes consistent with progressive radiation necrosis; one patient received a single additional dose of bevacizumab and the other patient received two doses. Conclusion: The Class I evidence of bevacizumab efficacy from the present study in the treatment of central nervous system radiation necrosis justifies consideration of this treatment option for people with radiation necrosis secondary to the treatment of head-and-neck cancer and brain cancer.« less

  10. AQUILA Remotely Piloted Vehicle System Technology Demonstrator (RPV-STD) Program. Volume 2. System Evolution and Engineering Testing

    DTIC Science & Technology

    1979-04-01

    crosshead of the piston assembly. Shock transients at this location cause demagnetization of the magnet . This is being alleviated by in- stallation of magnets ...substantial structure, such as bulk - heads with edge cape. Soond, the wire-out foam *or* for the wing could not be sufficiently precise to preven the used for...characterize the power potential, fuel consumption, weight, bulk , and adaptability to closed loop control of candidate carburetion systems to be employed with

  11. Impact of speed and magnitude of weight loss on the development of brain trophic changes in adolescents with anorexia nervosa: a case control study.

    PubMed

    Bomba, Monica; Riva, Anna; Veggo, Federica; Grimaldi, Marco; Morzenti, Sabrina; Neri, Francesca; Nacinovich, Renata

    2013-02-19

    Anorexia nervosa commonly arises during adolescence and is associated with more than one medical morbidity. Abnormalities in brain structure (defined as "pseudoatrophy") are common in adolescents with anorexia nervosa; however, their correlations with endocrinological profiles and clinical parameters are still unclear. In particular, no study has described the impact of BMI (body mass index) variations (speed and magnitude of weight loss) on cerebral trophism changes. Eleven adolescents with anorexia nervosa and 8 healthy controls underwent cerebral MRI (magnetic resonance imaging) examination to obtain global and partial volumes (gray matter, white matter and cerebrospinal fluid) and clinical evaluation. The Mann-Whitney U test was used to compare partial volumes and clinical variables between cases and controls. The Spearman non-parametric test was performed in order to explore correlations between the variables studied. The patients diagnosed with AN showed significantly increased cerebrospinal fluid (CSF) volumes and decreased total gray (GM) and white matter (WM) volumes. The degree of weight loss (deltaBMI) correlated inversely with the GM volume; the increase of CSF compartment correlated directly with the rapidity of weight loss (DeltaBMI/disease duration). This study suggests a correlation between cerebral alterations in AN and the speed and magnitude of weight loss, and outlines its importance for the therapeutic treatment.

  12. Criterion 6, indicator 25: Value and volume of wood and wood products production, including primary and secondary processing

    Treesearch

    James L. Howard; David B. McKeever; Ted Bilek

    2016-01-01

    Trend data through 2011 are provided on the value and volume of wood and wood products production for the United States to aid in assessing sustainability of socioeconomic benefits of forests. The volume of roundwood used to make products, the weight produced, and the value of U.S. shipments have fluctuated in recent years. But there have been decreases in the weight...

  13. The 1985 Army Experience Survey: Tabular Descriptions of Enlisted Retirees. Volume 2

    DTIC Science & Technology

    1986-01-01

    and sample management systems . Data were also keyed, edited, coded, and weighted. The coding schemes developed to classify written responses to the...34 ," . ." #".* " ’ ," ." ." ." " ." • --.........-.. ’...................,...".."."’............. . . . . 226 .! - R136 -- REGION OF RESIDENCE WHEN YOU JOINED...standards - Positive or negative 14: Pay/benefits/promotion - Poor Promotion practices/criteria - Point system - Weed out poor soldiers - Could not

  14. Monolithic microwave integrated circuit technology for advanced space communication

    NASA Technical Reports Server (NTRS)

    Ponchak, George E.; Romanofsky, Robert R.

    1988-01-01

    Future Space Communications subsystems will utilize GaAs Monolithic Microwave Integrated Circuits (MMIC's) to reduce volume, weight, and cost and to enhance system reliability. Recent advances in GaAs MMIC technology have led to high-performance devices which show promise for insertion into these next generation systems. The status and development of a number of these devices operating from Ku through Ka band will be discussed along with anticipated potential applications.

  15. Non-invasive volumetric analysis of asymptomatic hands using a 3-D scanner

    PubMed Central

    Shinkai, Hiroki; Yamamoto, Michiro; Tatebe, Masahiro; Iwatsuki, Katsuyuki; Kurimoto, Shigeru; Hirata, Hitoshi

    2017-01-01

    Hand swelling is one of the symptoms often seen in practice, but none of the available morphometric methods can quickly and efficiently quantify hand volume in an objective manner, and the current gold-standard volume measurement requires immersion in water, which can be difficult to use. Therefore, we aimed to analyze the accuracy of using 3-dimensional (3-D) scanning to measure hand volume. First, we compared the hand volume calculated using the 3-D scanner to that calculated from the conventional method among 109 volunteers to determine the reliability of 3-D measurements. We defined the beginning of the hand as the distal wrist crease, and 3-D forms of the hands were captured by the 3-D scanning system. Second, 238 volunteers (87 men, 151 women) with no disease or history of hand surgery underwent 3-D scanning. Data collected included age, height, weight, and shoe size. The wrist circumference (WC) and the distance between distal wrist crease and tip of middle finger (DDT) were measured. Statistical analyses were performed using linear regression to investigate the relationship between the hand volume and these parameters. In the first study, a significantly strong positive correlation was observed [R = 0.98] between the hand volume calculated via 3-D scanning and that calculated via the conventional method. In the second study, no significant differences between the volumes, WC or DDT of right and left hands were found. The correlations of hand volume with weight, WC, and DDT were strong. We created a formula to predict the hand volume using these parameters; these variables explained approximately 80% of the predicted volume. We confirmed that the new 3-D scanning method, which is performed without touching the hand and can record the form of the hand, yields an accurate volumetric analysis of an asymptomatic hand. PMID:28796816

  16. SU-F-T-200: Dosimetric Variation of Organs at Risk for Recurrent Nasopharyngeal Carcinoma (rNPC) Patients Treated by Carbon Ion Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, W; Sheng, Y; Shahnazi, K

    2016-06-15

    Purpose: Investigate the factors which affect the doses of organs at risk (OARs) for head and neck carbon ion therapy. Methods: Ten locally recurrent nasopharyngeal carcinoma cases with similar prescriptions were selected. All patients’ organs at risk (OARs) as well as CTVs were contoured by an experienced physician. Carbon ion treatment plans were created using a Syngo treatment planning system (Siemens, Germany). The CTVs were expanded to make optimized target volumes (OTVs) by considering treatment uncertainties and OAR protections. All plans were reviewed by this physician to be clinically acceptable. The OTV was expanded an additional 3mm to define themore » volume where beam spots could be put. A volume was also drawn 6 mm around the OTV to approximate the 50 % dose volume. The volumes where the OARs overlapped the OTV + 3 mm and OTV + 6 mm volumes, termed residual volumes, were then calculated. Results: The residual volumes within OTV + 3 mm were directly related to the OAR maximum dose. The percentage of the residual volume within the OTV + 6 mm with respect to the OAR volume was strongly related to the OAR mean doses. OAR mean doses also were affected by the beam setups. For example, if the OARs were in the beam entrance, the superior beams would sharply decrease the mean doses of the OARs hit by the lateral beams while increasing the mean doses of the OARs hit by the superior beam; the mean dose of the OARs which were hit by higher weight beams would be higher than the OARs hit by lower weight beams. Conclusion: Physicians should be cautious when contouring OARs, especially those close to CTVs and sensitive to large doses. Planners should set the OTV and beam parameters properly in order to save the OARs.« less

  17. Influence of body weight and body conformation on the pressure-volume curve during capnoperitoneum in dogs.

    PubMed

    Dorn, Melissa J; Bockstahler, Barbara A; Dupré, Gilles P

    2017-05-01

    OBJECTIVE To evaluate the pressure-volume relationship during capnoperitoneum in dogs and effects of body weight and body conformation. ANIMALS 86 dogs scheduled for routine laparoscopy. PROCEDURES Dogs were allocated into 3 groups on the basis of body weight. Body measurements, body condition score, and body conformation indices were calculated. Carbon dioxide was insufflated into the abdomen with a syringe, and pressure was measured at the laparoscopic cannula. Volume and pressure data were processed, and the yield point, defined by use of a cutoff volume (COV) and cutoff pressure (COP), was calculated. RESULTS 20 dogs were excluded because of recording errors, air leakage attributable to surgical flaws, or trocar defects. For the remaining 66 dogs, the pressure-volume curve was linear-like until the yield point was reached, and then it became visibly exponential. Mean ± SD COP was 5.99 ± 0.805 mm Hg. No correlation was detected between yield point, body variables, or body weight. Mean COV was 1,196.2 ± 697.9 mL (65.15 ± 20.83 mL of CO 2 /kg), and COV was correlated significantly with body weight and one of the body condition indices but not with other variables. CONCLUSION AND CLINICAL RELEVANCE In this study, there was a similar COP for all dogs of all sizes. In addition, results suggested that increasing the abdominal pressure after the yield point was reached did not contribute to a substantial increase in working space in the abdomen. No correlation was found between yield point, body variables, and body weight.

  18. The impact of using weight estimated from mammographic images vs. self-reported weight on breast cancer risk calculation

    NASA Astrophysics Data System (ADS)

    Nair, Kalyani P.; Harkness, Elaine F.; Gadde, Soujanye; Lim, Yit Y.; Maxwell, Anthony J.; Moschidis, Emmanouil; Foden, Philip; Cuzick, Jack; Brentnall, Adam; Evans, D. Gareth; Howell, Anthony; Astley, Susan M.

    2017-03-01

    Personalised breast screening requires assessment of individual risk of breast cancer, of which one contributory factor is weight. Self-reported weight has been used for this purpose, but may be unreliable. We explore the use of volume of fat in the breast, measured from digital mammograms. Volumetric breast density measurements were used to determine the volume of fat in the breasts of 40,431 women taking part in the Predicting Risk Of Cancer At Screening (PROCAS) study. Tyrer-Cuzick risk using self-reported weight was calculated for each woman. Weight was also estimated from the relationship between self-reported weight and breast fat volume in the cohort, and used to re-calculate Tyrer-Cuzick risk. Women were assigned to risk categories according to 10 year risk (below average <2%, average 2-3.49%, above average 3.5-4.99%, moderate 5-7.99%, high >=8%) and the original and re-calculated Tyrer-Cuzick risks were compared. Of the 716 women diagnosed with breast cancer during the study, 15 (2.1%) moved into a lower risk category, and 37 (5.2%) moved into a higher category when using weight estimated from breast fat volume. Of the 39,715 women without a cancer diagnosis, 1009 (2.5%) moved into a lower risk category, and 1721 (4.3%) into a higher risk category. The majority of changes were between below average and average risk categories (38.5% of those with a cancer diagnosis, and 34.6% of those without). No individual moved more than one risk group. Automated breast fat measures may provide a suitable alternative to self-reported weight for risk assessment in personalized screening.

  19. Production of stocker-size hybrid tilapia in an outdoor biofloc production system

    USDA-ARS?s Scientific Manuscript database

    Production efficiency per unit volume of water can be improved when stocking rate is adjusted to allow rapid growth of the culture organism to the desired target weight. Fingerlings often are grown to stocker size (ca. 100-150 g/fish) at high stocking rates and then the population is thinned to allo...

  20. Hydrostatic weighing at residual volume and functional residual capacity.

    PubMed

    Thomas, T R; Etheridge, G L

    1980-07-01

    Hydrostatic weighing (HW) was performed at both residual volume (RV) and functional residual capacity (FRC) to determine if underwater weighing at different lung volumes affected the measurement of body density. Subjects were 43 males, 18-25 yr. Subjects were submerged in the prone position, and the lung volume was measured by helium dilution at the time of the underwater weighing. Underwater weight was first assessed at FRC followed by assessment at RV. Changes in lung volume were accurately reflected in the underwater weight. Body density (D) was not different with the use of the FRC (mean D = 1.0778) or RV (mean D = 1.0781) data. Percent fat values for the FRC and RV data were 9.3 +/- 5.4 and 9.2 +/- 5.1%, respectively, and were not statistically different. The results indicate that the difference between percent fat determinations by HW in the prone position at FRC and RV is negligible. Because measurement of underwater weight at FRC is more comfortable for the subject, this may be the method of choice when the lung volume can be measured during the underwater weighing.

  1. Source imaging of drums in the APNEA system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, D.

    1995-12-31

    The APNea System is a neutron assay device utilizing both a passive mode and a differential-dieaway active mode. The total detection efficiency is not spatially uniform, even for an empty chamber, and a drum matrix in the chamber can severely distort this response. In order to achieve a response which is independent of the way the source material is distributed in a drum, an imaging procedure has been developed which treats the drum as a number of virtual (sub)volumes. Since each virtual volume of source material is weighted with the appropriate instrument parameters (detection efficiency and thermal flux), the finalmore » assay result is essentially independent of the actual distribution of the source material throughout the drum and its matrix.« less

  2. A randomized controlled trial of the effect of intrapartum intravenous fluid management on breastfed newborn weight loss.

    PubMed

    Watson, Jo; Hodnett, Ellen; Armson, B Anthony; Davies, Barbara; Watt-Watson, Judy

    2012-01-01

    To determine the effect of conservative versus usual intrapartum intravenous (IV) fluid management for low-risk women receiving epidural analgesia on weight loss in breastfed newborns. A randomized controlled trial. A tertiary perinatal center in a large urban setting. Women experiencing uncomplicated pregnancies who planned to have epidural analgesia and to breastfeed. Healthy pregnant women were randomized to receive an IV epidural preload volume of <500 mLs continuing at an hourly rate of 75-100 mL/h (conservative care) or an epidural preload volume of ≥500 mLs and an hourly rate >125 mL/h (usual care). The primary study outcome was breastfed newborn weight loss >7% prior to hospital discharge. Secondary study outcomes included breastfeeding exclusivity, referral to outpatient breastfeeding clinic support, and delayed discharge. Other outcomes were admission to the neonatal intensive care unit and cord blood pH <7.25. Two hundred women participated (100 in the conservative care and 100 in the usual care groups). Forty-eight of 100 infants in the usual care group and 44 of the 100 infants in the conservative care group lost >7% of their birth weight prior to discharge, p < 0.52 RR 0.92 [0.68-1.24]. A policy of restricted IV fluids did not affect newborn weight loss. Women and their care providers should be reassured that the volumes of IV fluid <2500 mLs are unlikely to have a clinically meaningful effect on breastfed newborn weight loss >7%. Exploratory analyses suggest that breastfed newborn weight loss increases when intrapartum volumes infused are >2500 mLs. Care providers are encouraged to consider volumes of IV fluid infused intrapartum as a factor that may have contributed to early newborn weight loss in the first 48 h of life. © 2012 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.

  3. Benign prostate hyperplasia: average volume in southwestern Nigerians and correlation with anthropometrics.

    PubMed

    Badmus, T A; Asaleye, C M; Badmus, S A; Takure, A O; Ibrahim, M H; Arowolo, O A

    2012-03-01

    To determine the prevalent age of symptomatic benign prostate hyperplasia (BPH), the average BPH volume, and the association between BPH volumes and the age, and anthropometrics. Selected patients with lower urinary tract symptoms (LUTS) due to BPH with tissue diagnosis, and adult men of similar age group with no irritative or obstructive LUTS were prospectively studied from July 2003 to June 2009. The age, height and weight were recorded; prostate volumes determined with ultrasound, body mass index (BMI) calculated, and correlations determined between the prostate volume, the age and anthropometrics. One hundred and five patients aged 43-88years (mean=64.4, 8.88SD) managed for BPH were studied with 93 asymptomatic men aged 43-80years (mean=56.15, 9.89SD). The mean (SD) prostate volume, height, weight and BMI were 83.8(37.7) ml, 1.67(0.07) m, 63.6(9.32) kg and 22.8(3.03) kg/m2, and 24.5(9.2) ml, 1.69(0.06) m, 68.9(10.6) kg and 24.2(3.44) kg/m2 respectively for symptomatic and asymptomatic groups. In the symptomatic group, BPH volume showed significant positive correlation with the age (p=0.030), but no correlation with the weight (p=0.550), height (p=0.375) and BMI (p=0.840). In the asymptomatic group, prostate volume also showed significant positive correlation with the age (p=0.041), but no correlation with the weight (p=0.434), height (p= 0.394), and BMI (p=0.203). The prevalent age of symptomatic BPH in our community is 43-88years with 83.79(37.66) ml mean (SD) volume in symptomatic patients and 24.45(9.21) ml in asymptomatic men. BPH volume correlates with age but not with anthropometrics. Lack of correlation with BPH volume suggests that anthropometrics may not be risk factors for development of BPH.

  4. Benign prostate hyperplasia: average volume in southwestern Nigerians and correlation with anthropometrics.

    PubMed

    Badmus, T A; Asaleye, C M; Badmus, S A; Takure, A O; Ibrahim, M H; Arowolo, O A

    2013-03-01

    To determine the prevalent age of symptomatic benign prostate hyperplasia (BPH), the average BPH volume, and the association between BPH volumes and the age, and anthropometrics in our immediate black community. Selected patients with lower urinary tract symptoms (LUTS) due to BPH with tissue diagnosis, and adult men of similar age group with no irritative or obstructive LUTS were prospectively studied from July 2003 to June 2009. The age, height and weight were recorded, prostate volumes determined with ultrasound, body mass index (bmi) calculated, and correlations determined between the prostate volume and the age, and anthropometrics. 105 patients aged 43-88 yrs (mean=64.4, 8.88 SD) managed for BPH were studied with 93 asymptomatic men aged 43-80 yrs (mean=56.15, 9.89 SD). The mean (SD) prostate volume, height, weight and bmi were 83.8 (37.7) ml, 1.67 (0.07) m, 63.6 (9.32) kg and 22.8 (3.03) kg/m2, and 24.5 (9.2) ml, 1.69 (0.06) m, 68.9 (10.6) kg and 24.2 (3.44) kg/m2 respectively for symptomatic and asymptomatic groups. In the symptomatic group, BPH volume showed significant positive correlation with the age (p=0.030), but no correlation with the weight (p=0.550), height (p=0.375) and bmi (p=0.840). In the asymptomatic group, prostate volume also showed significant positive correlation with the age (p=0.041), but no correlation with the weight (p=0.434), height (p=0.394), and bmi (p=0.203). The prevalent age of symptomatic BPH in our community is 43- 88 years with 83.79 (37.66) ml mean (SD) volume in symptomatic patients and 24.45 (9.21) ml in asymptomatic men. BPH volume correlates with age but not with anthropometrics. Lack of correlation with BPH volume suggests that anthropometrics may not be risk factors for development of BPH in our community.

  5. Measurement of the volume of the pedicled TRAM flap in immediate breast reconstruction.

    PubMed

    Chang, K P; Lin, S D; Hou, M F; Lee, S S; Tsai, C C

    2001-12-01

    The transverse rectus abdominis musculocutaneous (TRAM) flap is now accepted as the standard for breast reconstruction, but achieving symmetrical breast reconstruction is still a challenge. A precise estimate of the volume of the flap is necessary to reconstruct a symmetrical and aesthetically pleasing breast. Many methods have been developed to overcome this problem, but they have not been suitable for the pedicled TRAM flap. By using a self-made device based on the Archimedes' principle, the authors can calculate accurately the volume of the pedicled TRAM flap and predict reliably the breast volume intraoperatively. The "procedure" is based on a self-made box into which the pedicled TRAM flap is placed. Warm saline is added to the box and the flap is then removed. Flap volume is calculated easily by determining the difference between the preestimated volume of the box and the volume of the residual water. From February to May 2000, this method was used on 28 patients to predict breast volume for breast reconstruction. This study revealed that the difference of the maximal chest circumferences (the index of the breast volume) demonstrates a positive correlation with the difference of the volumes and weights between the mastectomy specimen and the net TRAM flap. However, a more closely positive correlation exists between the differences of maximal chest circumference volume (r = 0.677) than maximal chest circumference weight (r = 0.618). These data reveal that the reconstructed breast's volume has a closer relationship with the volume of the net pedicled TRAM flap, rather than with its weight.

  6. The applicability of frame imaging from a spinning spacecraft. Volume 1: Summary report

    NASA Technical Reports Server (NTRS)

    Botticelli, R. A.; Johnson, R. O.; Wallmark, G. N.

    1973-01-01

    A detailed study was made of frame-type imaging systems for use on board a spin stabilized spacecraft for outer planets applications. All types of frame imagers capable of performing this mission were considered, regardless of the current state of the art. Detailed sensor models of these systems were developed at the component level and used in the subsequent analyses. An overall assessment was then made of the various systems based upon results of a worst-case performance analysis, foreseeable technology problems, and the relative reliability and radiation tolerance of the systems. Special attention was directed at restraints imposed by image motion and the limited data transmission and storage capability of the spacecraft. Based upon this overall assessment, the most promising systems were selected and then examined in detail for a specified Jupiter orbiter mission. The relative merits of each selected system were then analyzed, and the system design characteristics were demonstrated using preliminary configurations, block diagrams, and tables of estimated weights, volumes and power consumption.

  7. Particle sizing by weighted measurements of scattered light

    NASA Technical Reports Server (NTRS)

    Buchele, Donald R.

    1988-01-01

    A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.

  8. Evaluation of sweet sorghum (Sorghum bicolor L. [Moench]) on several population density for bioethanol production

    NASA Astrophysics Data System (ADS)

    Suwarti; Efendi, R.; Massinai, R.; Pabendon, M. B.

    2018-03-01

    Sweet sorghum (Sorghum bicolor L. [Moench]) crop management that is use for raw source of bioethanol for industrial purpose in Indonesia is less developed. The aim of this research was to evaluated sweet sorghum variety at several population to determine optimum density for juice production. Experiment design was set on split-plot design with three replications, conducted on August to December 2016 at the Indonesian Cereals Research Institute Research Station, Maros South Sulawesi. Main plot were six variation of plant row, and sub plot were three sweet sorghum varieties. Result of the study showed that plant population was high significanty affect to stalk weight, total biomass yield, leaf weight, and also significantly affect bagass weight and juice volume. Varieties were high significantly different in plant height, juice volume, and number of nodes. Super 1 variety on population at 166,667 plants/ha (P1) was obtained the highest juice volume (19,445 lHa-1), meanwhile the highest brix value obtained from Numbu at the same plants population. Furthermore juice volume had significant correlation with biomass weight at the r=0.73. Based on ethanol production, Super 2 and Numbu had the highest volume at 83.333 plants/ha density (P3) and Super 1 at 166.667 plants/ha density with the ethanol volume were 827.68 l Ha-1, 1116.50 l/ha and 993.62 l Ha-1 respectively.

  9. Power Extension Package (PEP) system definition extension, orbital service module systems analysis study. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1979-01-01

    An array deployment assembly, power regulation and control assembly, the necessary interface, and display and control equipment comprise the power extension package (PEP) which is designed to provide increased power and duration, as well as reduce fuel cell cryogen consumption during Spacelab missions. Compatible with all currently defined missions and payloads, PEP imposes minimal weight and volume penalties on sortie missions, and can be installed and removed as needed at the launch site within the normal Orbiter turnaround cycle. The technology on which it is based consists of a modified solar electric propulsion array, standard design regulator and control equipment, and a minimally modified Orbiter design. The requirements from which PEP was derived, and the system and its performance capabilities are described. Features of the recommended project are presented.

  10. Flight Control System for the CRCA (Control Reconfigurable Combat Aircraft) Using a Command Generator Tracker with PI (Plus Integral) Feedback and Kalman Filter. Volume 2

    DTIC Science & Technology

    1989-03-01

    IAutomatic Control, AC-22, p 883-885, 1977 /Syntax check EIGA=EIG(A); EIGB=EIG(B); [M,N)=SIZE(EIGA); [PR] SIZE(EIGB); FOR 11I:M,FOR JlI:P,.... EIGAB=EIGA...AIM = implicit model A matrix I/ QI = weighting matrix, ouputs mimic model I/ RI = weighting matrix, controls mimic model // QIHAT = implicit cost II...the dimension is less than 1. // NINPUTS (the number of controls and outputs) is the flag for the dimensio // of the connections. /- // The name of

  11. Design of a Capacitive Flexible Weighing Sensor for Vehicle WIM System

    PubMed Central

    Cheng, Lu; Zhang, Hongjian; Li, Qing

    2007-01-01

    With the development of the Highway Transportation and Business Trade, vehicle weigh-in-motion (WIM) technology has become a key technology and trend of measuring traffic loads. In this paper, a novel capacitive flexible weighing sensor which is light weight, smaller volume and easy to carry was applied in the vehicle WIM system. The dynamic behavior of the sensor is modeled using the Maxwell-Kelvin model because the materials of the sensor are rubbers which belong to viscoelasticity. A signal processing method based on the model is presented to overcome effects of rubber mechanical properties on the dynamic weight signal. The results showed that the measurement error is less than ±10%. All the theoretic analysis and numerical results demonstrated that appliance of this system to weigh in motion is feasible and convenient for traffic inspection.

  12. Preservation of Liquid Biological Samples

    NASA Technical Reports Server (NTRS)

    Putcha, Lakshmi (Inventor); Nimmagudda, Ramalingeshwara R. (Inventor)

    2000-01-01

    The present invention provides a method of preserving a liquid biological sample, comprising the step of: contacting said liquid biological sample with a preservative comprising, sodium benzoate in an amount of at least about 0.15% of the sample (weight/volume) and citric acid in an amount of at least about 0.025% of the sample (weight/volume).

  13. Individual tree, merchantable stem green weight and volume equations for four bottomland hardwood oak species in southeast Arkansas

    Treesearch

    Paul F. Doruska; David W. Patterson; Matthew B. Hurd; Jonathan I. Hartley

    2013-01-01

    Equations were developed to estimate outside-bark, merchantable stem green weight (lb) and inside-bark merchantable stem volume (ft3) for sawtimber-sized Nuttall oak (Quercus texana Buckley), overcup oak (Quercus lyrata Walt.), water oak (Quercus nigra L.), and willow oak (Quercus...

  14. 19 CFR 146.94 - Records concerning establishment of manufacturing period.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... using the FIFO method (see section II of the appendix to this part). (d) Gain or loss. A gain or loss... entered for consumption unless otherwise exempt from duty. (e) Determining gain or loss; acceptable methods—(1) Converting volume to weight. Volume measurements may be converted to weight measurements using...

  15. 19 CFR 146.94 - Records concerning establishment of manufacturing period.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... using the FIFO method (see section II of the appendix to this part). (d) Gain or loss. A gain or loss... entered for consumption unless otherwise exempt from duty. (e) Determining gain or loss; acceptable methods—(1) Converting volume to weight. Volume measurements may be converted to weight measurements using...

  16. 7 CFR 920.303 - Container marking regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... of kiwifruit packed within the container: (1) The quantity shall be indicated in terms of count and... shall conform to the count. (2) The quantity shall be indicated in terms of the size designation and either the net weight for volume-fill containers packed by weight or the count for volume-fill containers...

  17. Protective mechanical ventilation in United Kingdom critical care units: A multicentre audit

    PubMed Central

    Martin, Matthew J; Richardson, Neil; Bourdeaux, Christopher P

    2016-01-01

    Lung protective ventilation is becoming increasingly used for all critically ill patients being mechanically ventilated on a mandatory ventilator mode. Compliance with the universal application of this ventilation strategy in intensive care units in the United Kingdom is unknown. This 24-h audit of ventilation practice took place in 16 intensive care units in two regions of the United Kingdom. The mean tidal volume for all patients being ventilated on a mandatory ventilator mode was 7.2(±1.4) ml kg−1 predicted body weight and overall compliance with low tidal volume ventilation (≤6.5 ml kg−1 predicted body weight) was 34%. The mean tidal volume for patients ventilated with volume-controlled ventilation was 7.0(±1.2) ml kg−1 predicted body weight and 7.9(±1.8) ml kg−1 predicted body weight for pressure-controlled ventilation (P < 0.0001). Overall compliance with recommended levels of positive end-expiratory pressure was 72%. Significant variation in practice existed both at a regional and individual unit level. PMID:28979556

  18. Protective mechanical ventilation in United Kingdom critical care units: A multicentre audit.

    PubMed

    Newell, Christopher P; Martin, Matthew J; Richardson, Neil; Bourdeaux, Christopher P

    2017-05-01

    Lung protective ventilation is becoming increasingly used for all critically ill patients being mechanically ventilated on a mandatory ventilator mode. Compliance with the universal application of this ventilation strategy in intensive care units in the United Kingdom is unknown. This 24-h audit of ventilation practice took place in 16 intensive care units in two regions of the United Kingdom. The mean tidal volume for all patients being ventilated on a mandatory ventilator mode was 7.2(±1.4) ml kg -1 predicted body weight and overall compliance with low tidal volume ventilation (≤6.5 ml kg -1 predicted body weight) was 34%. The mean tidal volume for patients ventilated with volume-controlled ventilation was 7.0(±1.2) ml kg -1 predicted body weight and 7.9(±1.8) ml kg -1 predicted body weight for pressure-controlled ventilation ( P  < 0.0001). Overall compliance with recommended levels of positive end-expiratory pressure was 72%. Significant variation in practice existed both at a regional and individual unit level.

  19. Aircraft Icing Handbook. Volume 2

    DTIC Science & Technology

    1991-03-01

    an airfoil surface. icenhobig - A surface property exhibiting a reduced adhesion to ice; literally, "ice-hating." light icing - The rate of...power, and are a light weight system of reasonable cost. K. ill I-I1 1.I.2 Pneumatic Impulse Ice Protection A Pneumatic Impulse Ice Protection System...should be about 5 to 6 seconds. During moderate icing a 60 second cycle is suggested, while for light icing, longer accretion times of 3 to 4 minutes

  20. Physical Activity Patterns in Normal-Weight and Overweight/Obese Pregnant Women

    PubMed Central

    Bacchi, Elisabetta; Bonin, Cecilia; Zanolin, Maria Elisabetta; Zambotti, Francesca; Livornese, Dario; Donà, Silvia; Tosi, Flavia; Baldisser, Giulia; Ihnatava, Tatsiana; Di Sarra, Daniela; Bonora, Enzo; Moghetti, Paolo

    2016-01-01

    The aims of the present study were to assess the volume of physical activity (PA) throughout pregnancy in normal-weight vs overweight/obese women, and to investigate which factors may predict compliance to PA recommendations in these women throughout gestation. In 236 pregnant women, 177 normal-weight and 59 overweight/obese (median[IQR] BMI 21.2[19.9–22.8] vs 26.5[25.5–29.0] kg/m2, respectively), medical history, anthropometry and clinical data, including glucose tolerance, were recorded. In addition, pre-pregnancy PA was estimated by the Kaiser questionnaire, while total, walking and fitness/sport PA during pregnancy were assessed by the Physical Activity Scale for the Elderly (PASE) modified questionnaire, at 14–16, 24–28 and 30–32 weeks of gestation. PA volume was very low in the first trimester of pregnancy in both groups of women. However, it increased in the second and third trimester in normal-weight, but not in overweight/obese subjects. Higher pre-pregnancy PA was a statistically significant predictor of being physically active (>150 minutes of PA per week) during all trimesters of gestation. In conclusion, physical activity volume is low in pregnant women, especially in overweight/obese subjects. PA volume increases during pregnancy only in normal-weight women. Pre-pregnancy PA is an independent predictor of achieving a PA volume of at least 150 min per week during pregnancy. PMID:27829017

  1. PREOPERATIVE COMPUTED TOMOGRAPHY VOLUMETRY AND GRAFT WEIGHT ESTIMATION IN ADULT LIVING DONOR LIVER TRANSPLANTATION

    PubMed Central

    PINHEIRO, Rafael S.; CRUZ-JR, Ruy J.; ANDRAUS, Wellington; DUCATTI, Liliana; MARTINO, Rodrigo B.; NACIF, Lucas S.; ROCHA-SANTOS, Vinicius; ARANTES, Rubens M; LAI, Quirino; IBUKI, Felicia S.; ROCHA, Manoel S.; D´ALBUQUERQUE, Luiz A. C.

    2017-01-01

    ABSTRACT Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r2=0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 - 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. PMID:28489167

  2. Integrated air revitalization system for Space Station

    NASA Technical Reports Server (NTRS)

    Boyda, R. B.; Miller, C. W.; Schwartz, M. R.

    1986-01-01

    Fifty-one distinct functions are encompassed by the Space Station's Environmental Control and Life Support System; one exception to this noninteractivity of functions is the regenerative air revitalization system that removes and reduces CO2 and generates O2. The integration of these interdependent functions, and of humidity control, into a single system furnishes opportunities for process simplification as well as for power, weight and volume requirement reductions by comparison with discrete subsystems. Attention is presently given to a system which quantifies these integration-related savings and identifies additional advantages that accrue to this integrating design method.

  3. Effect of hydration on interstitial distribution of charged albumin in rat dermis in vitro

    PubMed Central

    Wiig, Helge; Tenstad, Olav; Bert, Joel L

    2005-01-01

    At physiological pH, negatively charged glycosaminoglycans in the extracellular matrix may influence distribution volume of macromolecular probes, a phenomenon of importance for hydration of the interstitium and therefore for body fluid balance. We hypothesized that such charge effect was dependent on hydration. Human serum albumin (HSA) (the pH value for the isoelectric point (pI) = 4.9) was made neutral by cationization (cHSA) (pI = 7.6). Rat dermis was studied in vitro in a specially designed equilibration cell allowing control of hydration. Using a buffer containing labelled native HSA and cHSA, the distribution volumes were calculated relative to that of 51Cr-EDTA, an extracellular tracer. During changes in hydration (H), defined as (wet weight – dry weight) (dry weight)−1), the slope of the equation describing the relationship between extracellular fluid volume (Vx) (in g H2O (g dry weight)−1) and H (Vx = 0.925 H + 0.105) differed significantly from that for available volumes of cHSA (Va,cHSA = 0.624 H – 0.538) and HSA (Va,HSA = 0.518 H – 0.518). A gradual reduction in H led to a reduction in difference between available volumes for the two albumin species. Screening the fixed charges by 1 m NaCl resulted in similar available and excluded volumes of native HSA and neutral cHSA. We conclude that during gradual dehydration, there is a reduced effect of fixed negative charges on interstitial exclusion of charged macromolecules. This effect may be explained by a reduced hydration domain surrounding tissue and probe macromolecules in conditions of increased electrostatic interactions. Furthermore, screening of negative charges suggested that hyaluronan associated with collagen may influence intrafibrillar volume of collagen and thereby available and excluded volume fraction. PMID:16210353

  4. [Hemapheresis using vesicular plant separation materials].

    PubMed

    Mavrina, L; Ehwald, R; Matthes, G; Stamminger, G

    1990-01-01

    The present paper deals with the separation of cells from soluble compounds of blood by means of exclusion chromatography using a recently described vesicular packing material made from the cell wall framework of the small duckweed Wolffia arrhiza. The cells of the periphere blood are hardly retarded in passing through a packing of the vesicular material and eluted as sharp peak at an elution volume which is near to 30% of the column volume. The behavior of cells is similar to that of the excluded high molecular weight plasma proteins (e.g. serumalbumin). Low molecular weight solutes (e.g. salts, glucose, urea, kreatinin), but also substances of considerable molecular weight (e.g. myoglobin and Vitamin B12) which are usually difficult to separate by dialysis from serum, are eluted at nearly 100% of the packing volume and may be separated completely from cells and high molecular weight proteins. In vitro-Tests did not show a reduced vitality of eluted blood cells.

  5. Solid State Ultracapacitor

    NASA Technical Reports Server (NTRS)

    Hill, Curtis W. (Inventor); Rolin, Terry D. (Inventor)

    2018-01-01

    An ink of the formula: 60-80% by weight BaTiO3 particles coated with SiO2; 5-50% by weight high dielectric constant glass; 0.1-5% by weight surfactant; 5-25% by weight solvent; and 5-25% weight organic vehicle. Also a method of manufacturing a capacitor comprising the steps of: heating particles of BaTiO3 for a special heating cycle, under a mixture of 70-96% by volume N2 and 4-30% by volume H2 gas; depositing a film of SiO2 over the particles; mechanically separating the particles; incorporating them into the above described ink formulation; depositing the ink on a substrate; and heating at 850-900 C for less than 5 minutes and allowing the ink and substrate to cool to ambient in N2 atmosphere. Also a dielectric made by: heating particles of BaTiO3 for a special heating cycle, under a mixture of 70-96% by volume N2 and 4-30% by volume H2 gas; depositing a film of SiO2 over the particles; mechanically separating the particles; forming them into a layer; and heating at 850-900 C for less than 5 minutes and allowing the layer to cool to ambient in N2 atmosphere.

  6. Understanding Thiel Embalming in Pig Kidneys to Develop a New Circulation Model

    PubMed Central

    Willaert, Wouter; De Vos, Marie; Van Hoof, Tom; Delrue, Louke; Pattyn, Piet; D’Herde, Katharina

    2015-01-01

    The quality of tissue preservation in Thiel embalmed bodies varies. Research on the administered embalming volume and its vascular distribution may elucidate one of the mechanisms of tissue preservation and allow for new applications of Thiel embalming. Vascular embalming with (group 1, n = 15) or without (group 2, n = 20) contrast agent was initiated in pig kidneys. The distribution of Thiel embalming solution in group 1 was visualized using computed tomography. The kidneys in both groups were then immersed in concentrated salt solutions to reduce their weight and volume. Afterwards, to mimic a lifelike circulation in the vessels, group 2 underwent pump-driven reperfusion for 120 minutes with either paraffinum perliquidum or diluted polyethylene glycol. The circulation was imaged with computed tomography. All of the kidneys were adequately preserved. The embalming solution spread diffusely in the kidney, but fluid accumulation was present. Subsequent immersion in concentrated salt solutions reduced weight (P < 0.01) and volume (P < 0.01). Reperfusion for 120 minutes was established in group 2. Paraffinum perliquidum filled both major vessels and renal tissue, whereas diluted polyethylene glycol spread widely in the kidney. There were no increases in weight (P = 0.26) and volume (P = 0.79); and pressure further decreased (P = 0.032) after more than 60 minutes of reperfusion with paraffinum perliquidum, whereas there were increases in weight (P = 0.005), volume (P = 0.032) and pressure (P < 0.0001) after reperfusion with diluted polyethylene glycol. Arterial embalming of kidneys results in successful preservation due to complete parenchymatous spreading. More research is needed to determine whether other factors affect embalming quality. Dehydration is an effective method to regain the organs’ initial status. Prolonged vascular reperfusion with paraffinum perliquidum can be established in this model without increases in weight, volume and pressure. PMID:25806527

  7. Brain structural correlates of reward sensitivity and impulsivity in adolescents with normal and excess weight.

    PubMed

    Moreno-López, Laura; Soriano-Mas, Carles; Delgado-Rico, Elena; Rio-Valle, Jacqueline S; Verdejo-García, Antonio

    2012-01-01

    Neuroscience evidence suggests that adolescent obesity is linked to brain dysfunctions associated with enhanced reward and somatosensory processing and reduced impulse control during food processing. Comparatively less is known about the role of more stable brain structural measures and their link to personality traits and neuropsychological factors on the presentation of adolescent obesity. Here we aimed to investigate regional brain anatomy in adolescents with excess weight vs. lean controls. We also aimed to contrast the associations between brain structure and personality and cognitive measures in both groups. Fifty-two adolescents (16 with normal weight and 36 with excess weight) were scanned using magnetic resonance imaging and completed the Sensitivity to Punishment and Sensitivity to Reward Questionnaire (SPSRQ), the UPPS-P scale, and the Stroop task. Voxel-based morphometry (VBM) was used to assess possible between-group differences in regional gray matter (GM) and to measure the putative differences in the way reward and punishment sensitivity, impulsivity and inhibitory control relate to regional GM volumes, which were analyzed using both region of interest (ROI) and whole brain analyses. The ROIs included areas involved in reward/somatosensory processing (striatum, somatosensory cortices) and motivation/impulse control (hippocampus, prefrontal cortex). Excess weight adolescents showed increased GM volume in the right hippocampus. Voxel-wise volumes of the second somatosensory cortex (SII) were correlated with reward sensitivity and positive urgency in lean controls, but this association was missed in excess weight adolescents. Moreover, Stroop performance correlated with dorsolateral prefrontal cortex volumes in controls but not in excess weight adolescents. Adolescents with excess weight have structural abnormalities in brain regions associated with somatosensory processing and motivation.

  8. Estimated Nephron Number of the Donor Kidney: Impact on Allograft Kidney Outcomes.

    PubMed

    Schachtner, T; Reinke, P

    Low birth weights have been associated with a reduction in nephron number with compensatory hypertrophy of existing glomeruli. The impact of donor birth weight as an estimate of nephron number on allograft function, however, has not been examined. We collected donor birth weight, kidney weight, and volume from 91 living kidney donor-recipient pairs before nephrectomy and after 12, 36, and 60 months. Nephron number was calculated from donor birth weight and age. Donor birth weight, kidney weight/body surface area (BSA), and kidney volume showed a moderate positive correlation with allograft estimated glomerular filtration rate (eGFR) at 12 months (P < .05). Donor age showed a negative moderate correlation with allograft eGFR at 12 months (P = .015). The strongest correlation with allograft eGFR was observed for calculated donor kidney nephron number at 12, 36, and 60 months (R, 0.340, 0.305, and 0.476, respectively; P < .05). No impact was observed on allograft daily proteinuria of any investigated marker (P > .05). Recipients of donors with birth weight <2.5 kg had need of a significantly greater number of antihypertensive drugs (P < .05). Calculated nephron number from donor birth weight and age is suggested to be superior to donor kidney weight/BSA and volume regarding allograft function. Calculated nephron number could estimate expected eGFR and guide decision making in cases of impaired allograft function. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. 42 CFR 419.31 - Ambulatory payment classification (APC) system and payment weights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... set forth in paragraph (a)(1) in unusual cases, such as low volume items and services, but may not... and in terms of resource use into APC groups. Except as specified in paragraph (a)(2) of this section, items and services within a group are not comparable with respect to the use of resources if the highest...

  10. 42 CFR 419.31 - Ambulatory payment classification (APC) system and payment weights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... set forth in paragraph (a)(1) in unusual cases, such as low volume items and services, but may not... and in terms of resource use into APC groups. Except as specified in paragraph (a)(2) of this section, items and services within a group are not comparable with respect to the use of resources if the highest...

  11. 40 CFR 60.5412 - What additional requirements must I meet for determining initial compliance with control devices...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (c) For each carbon adsorption system used as a control device to meet the requirements of paragraph... weight or greater as determined in accordance with the requirements of § 60.5413. (ii) You must reduce... than 20 parts per million by volume on a dry basis corrected to 3 percent oxygen as determined in...

  12. Does placental inflammation relate to brain lesions and volume in preterm infants?

    PubMed

    Reiman, Milla; Kujari, Harry; Maunu, Jonna; Parkkola, Riitta; Rikalainen, Hellevi; Lapinleimu, Helena; Lehtonen, Liisa; Haataja, Leena

    2008-05-01

    To evaluate the association between histologic inflammation of placenta and brain findings in ultrasound examinations and regional brain volumes in magnetic resonance imaging in very-low-birth-weight (VLBW) or in very preterm infants. VLBW or very preterm infants (n = 121) were categorized into 3 groups according to the most pathologic brain finding on ultrasound examinations until term. The brain magnetic resonance imaging performed at term was analyzed for regional brain volumes. The placentas were analyzed for histologic inflammatory findings. Histologic chorioamnionitis on the fetal side correlated to brain lesions in univariate but not in multivariate analyses. Low gestational age was the only significant risk factor for brain lesions in multivariate analysis (P < .0001). Histologic chorioamnionitis was not associated with brain volumes in multivariate analyses. Female sex, low gestational age, and low birth weight z score correlated to smaller volumes in total brain tissue (P = .001, P = .0002, P < .0001, respectively) and cerebellum (P = .047, P = .003, P = .001, respectively). In addition, low gestational age and low-birth-weight z score correlated to a smaller combined volume of basal ganglia and thalami (P = .0002). Placental inflammation does not appear to correlate to brain lesions or smaller regional brain volumes in VLBW or in very preterm infants at term age.

  13. Phase 1 of the near team hybrid passenger vehicle development program. Appendix C: Preliminary design data package, volume 1

    NASA Technical Reports Server (NTRS)

    Piccolo, R.

    1979-01-01

    The methodology used for vehicle layout and component definition is described as well as techniques for system optimization and energy evaluation. The preliminary design is examined with particular attention given to body and structure; propulsion system; crash analysis and handling; internal combustion engine; DC motor separately excited; Ni-Zn battery; transmission; control system; vehicle auxiliarries; weight breakdown, and life cycle costs. Formulas are given for the quantification of energy consumption and results are compared with the reference vehicle.

  14. Logging residues on Douglas-fir region clearcuts—weights and volumes.

    Treesearch

    John D. Dell; Franklin R. Ward

    1971-01-01

    This paper presents the results of ground measurements of logging residue weights and volumes on 30 clearcut units in Douglas-fir forests of western Oregon and Washington. Additional information is given on quantities of material left as slash which might be utilized. These measurements were made on public lands, using a method developed in Canada.

  15. Weight, Volume, and Physical Properties of Major Hardwood Species in the Upland-South

    Treesearch

    Alexander Clark; Douglas R. Phillips; Douglas J. Frederick

    1986-01-01

    The weight, volume, and physical properties oftrees1 to 20 inchesd.b.h.were determined for sweetgum, yellow-poplar, hickory, post oak, scarlet oak, southern red oak, and white oakin northern Alabama and Mississippi, eastern Arkansas, southern Kentucky and Tennessee. Hard hardwoods, soft hardwoods, and individual species equations are presented for predicting green and...

  16. 16 CFR 503.4 - Net quantity of contents, numerical count.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... terms of count only, or in terms of count and weight, volume, area, or dimension, the regulations are... provide a net quantity statement to specify weight, volume, area, or dimensions when such are required. For example, the synthetic sponge which is packaged, requires dimensions such as “5 in. × 3 in. × 1 in...

  17. 16 CFR 503.4 - Net quantity of contents, numerical count.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... terms of count only, or in terms of count and weight, volume, area, or dimension, the regulations are... provide a net quantity statement to specify weight, volume, area, or dimensions when such are required. For example, the synthetic sponge which is packaged, requires dimensions such as “5 in. × 3 in. × 1 in...

  18. 16 CFR 503.4 - Net quantity of contents, numerical count.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... terms of count only, or in terms of count and weight, volume, area, or dimension, the regulations are... provide a net quantity statement to specify weight, volume, area, or dimensions when such are required. For example, the synthetic sponge which is packaged, requires dimensions such as “5 in. × 3 in. × 1 in...

  19. 16 CFR 503.4 - Net quantity of contents, numerical count.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... terms of count only, or in terms of count and weight, volume, area, or dimension, the regulations are... provide a net quantity statement to specify weight, volume, area, or dimensions when such are required. For example, the synthetic sponge which is packaged, requires dimensions such as “5 in. × 3 in. × 1 in...

  20. Understanding PSA and its derivatives in prediction of tumor volume: addressing health disparities in prostate cancer risk stratification

    PubMed Central

    Chinea, Felix M; Lyapichev, Kirill; Epstein, Jonathan I; Kwon, Deukwoo; Smith, Paul Taylor; Pollack, Alan; Cote, Richard J; Kryvenko, Oleksandr N

    2017-01-01

    Objectives To address health disparities in risk stratification of U.S. Hispanic/Latino men by characterizing influences of prostate weight, body mass index, and race/ethnicity on the correlation of PSA derivatives with Gleason score 6 (Grade Group 1) tumor volume in a diverse cohort. Results Using published PSA density and PSA mass density cutoff values, men with higher body mass indices and prostate weights were less likely to have a tumor volume <0.5 cm3. Variability across race/ethnicity was found in the univariable analysis for all PSA derivatives when predicting for tumor volume. In receiver operator characteristic analysis, area under the curve values for all PSA derivatives varied across race/ethnicity with lower optimal cutoff values for Hispanic/Latino (PSA=2.79, PSA density=0.06, PSA mass=0.37, PSA mass density=0.011) and Non-Hispanic Black (PSA=3.75, PSA density=0.07, PSA mass=0.46, PSA mass density=0.008) compared to Non-Hispanic White men (PSA=4.20, PSA density=0.11 PSA mass=0.53, PSA mass density=0.014). Materials and Methods We retrospectively analyzed 589 patients with low-risk prostate cancer at radical prostatectomy. Pre-operative PSA, patient height, body weight, and prostate weight were used to calculate all PSA derivatives. Receiver operating characteristic curves were constructed for each PSA derivative per racial/ethnic group to establish optimal cutoff values predicting for tumor volume ≥0.5 cm3. Conclusions Increasing prostate weight and body mass index negatively influence PSA derivatives for predicting tumor volume. PSA derivatives’ ability to predict tumor volume varies significantly across race/ethnicity. Hispanic/Latino and Non-Hispanic Black men have lower optimal cutoff values for all PSA derivatives, which may impact risk assessment for prostate cancer. PMID:28160549

  1. Eating meals before wheel-running exercise attenuate high fat diet-driven obesity in mice under two meals per day schedule.

    PubMed

    Sasaki, Hiroyuki; Hattori, Yuta; Ikeda, Yuko; Kamagata, Mayo; Shibata, Shigenobu

    2015-06-01

    Mice that exercise after meals gain less body weight and visceral fat compared to those that exercised before meals under a one meal/exercise time per day schedule. Humans generally eat two or three meals per day, and rarely have only one meal. To extend our previous observations, we examined here whether a "two meals, two exercise sessions per day" schedule was optimal in terms of maintaining a healthy body weight. In this experiment, "morning" refers to the beginning of the active phase (the "morning" for nocturnal animals). We found that 2-h feeding before 2-h exercise in the morning and evening (F-Ex/F-Ex) resulted in greater attenuation of high fat diet (HFD)-induced weight gain compared to other combinations of feeding and exercise under two daily meals and two daily exercise periods. There were no significant differences in total food intake and total wheel counts, but feeding before exercise in the morning groups (F-Ex/F-Ex and F-Ex/Ex-F) increased the morning wheel counts. These results suggest that habitual exercise after feeding in the morning and evening is more effective for preventing HFD-induced weight gain. We also determined whether there were any correlations between food intake, wheel rotation, visceral fat volume and skeletal muscle volumes. We found positive associations between gastrocnemius muscle volumes and morning wheel counts, as well as negative associations between morning food intake volumes/body weight and morning wheel counts. These results suggest that morning exercise-induced increase of muscle volume may refer to anti-obesity. Evening exercise is negatively associated with fat volume increases, suggesting that this practice may counteract fat deposition. Our multifactorial analysis revealed that morning food intake helps to increase exercise, and that evening exercise reduced fat volumes. Thus, exercise in the morning or evening is important for preventing the onset of obesity.

  2. Design, fabrication and acceptance testing of a zero gravity whole body shower, volume 1

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The effort to design whole body shower for the space station prototype is reported. Clothes and dish washer/dryer concepts were formulated with consideration given to integrating such a system with the overall shower design. Water recycling methods to effect vehicle weight savings were investigated and it was concluded that reusing wash and/or rinse water resulted in weight savings which were not sufficient to outweigh the added degree of hardware complexity. The formulation of preliminary and final designs for the shower are described. A detailed comparison of the air drag vs. vacuum pickup method was prepared that indicated the air drag concept results in more severe space station weight penalties; therefore, the preliminary system design was based on utilizing the vacuum pickup method. Tests were performed to determine the optimum methods of storing, heating and sterilizing the cleansing agent utilized in the shower; it was concluded that individual packages of pre-sterilized cleansing agent should be used. Integration features with the space station prototype system were defined and incorporated into the shower design as necessary.

  3. In situ femoral dual-energy X-ray absorptiometry related to ash weight, bone size and density, and its relationship with mechanical failure loads of the proximal femur.

    PubMed

    Lochmüller, E M; Miller, P; Bürklein, D; Wehr, U; Rambeck, W; Eckstein, F

    2000-01-01

    The objective of this study was to directly compare in situ femoral dual-energy X-ray absorptiometry (DXA) and in vitro chemical analysis (ash weight and calcium) with mechanical failure loads of the proximal femur, and to determine the influence of bone size (volume) and density on mechanical failure and DXA-derived areal bone mineral density (BMD, in g/cm2). We performed femoral DXA in 52 fixed cadavers (age 82.1 +/- 9.7 years; 30 male, 22 female) with intact skin and soft tissues. The femora were then excised, mechanically loaded to failure in a stance phase configuration, their volume measured with a water displacement method (proximal neck to lesser trochanter), and the ash weight and calcium content of this region determined by chemical analysis. The correlation coefficient between the bone mineral content (measured in situ with DXA) and the ash weight was r = 0.87 (standard error of the estimate = 16%), the ash weight allowing for a better prediction of femoral failure loads (r = 0.78; p < 0.01) than DXA (r = 0.67; p < 0.01). The femoral volume (r = 0.61; p < 0.01), but not the volumetric bone density (r = 0.26), was significantly associated with the failure load. The femoral bone volume had a significant impact (r = 0.35; p < 0.01) on the areal BMD (DXA), and only 63% of the variability of bone volume could be predicted (based on the basis of body height, weight and femoral projectional bone area. The results suggest that accuracy errors of femoral DXA limit the prediction of mechanical failure loads, and that the influence of bone size on areal BMD cannot be fully corrected by accounting for body height, weight and projected femoral area.

  4. Launch Vehicle Propulsion Parameter Design Multiple Selection Criteria

    NASA Technical Reports Server (NTRS)

    Shelton, Joey Dewayne

    2004-01-01

    The optimization tool described herein addresses and emphasizes the use of computer tools to model a system and focuses on a concept development approach for a liquid hydrogen/liquid oxygen single-stage-to-orbit system, but more particularly the development of the optimized system using new techniques. This methodology uses new and innovative tools to run Monte Carlo simulations, genetic algorithm solvers, and statistical models in order to optimize a design concept. The concept launch vehicle and propulsion system were modeled and optimized to determine the best design for weight and cost by varying design and technology parameters. Uncertainty levels were applied using Monte Carlo Simulations and the model output was compared to the National Aeronautics and Space Administration Space Shuttle Main Engine. Several key conclusions are summarized here for the model results. First, the Gross Liftoff Weight and Dry Weight were 67% higher for the design case for minimization of Design, Development, Test and Evaluation cost when compared to the weights determined by the minimization of Gross Liftoff Weight case. In turn, the Design, Development, Test and Evaluation cost was 53% higher for optimized Gross Liftoff Weight case when compared to the cost determined by case for minimization of Design, Development, Test and Evaluation cost. Therefore, a 53% increase in Design, Development, Test and Evaluation cost results in a 67% reduction in Gross Liftoff Weight. Secondly, the tool outputs define the sensitivity of propulsion parameters, technology and cost factors and how these parameters differ when cost and weight are optimized separately. A key finding was that for a Space Shuttle Main Engine thrust level the oxidizer/fuel ratio of 6.6 resulted in the lowest Gross Liftoff Weight rather than at 5.2 for the maximum specific impulse, demonstrating the relationships between specific impulse, engine weight, tank volume and tank weight. Lastly, the optimum chamber pressure for Gross Liftoff Weight minimization was 2713 pounds per square inch as compared to 3162 for the Design, Development, Test and Evaluation cost optimization case. This chamber pressure range is close to 3000 pounds per square inch for the Space Shuttle Main Engine.

  5. Baseline Gray- and White Matter Volume Predict Successful Weight Loss in the Elderly

    PubMed Central

    Mokhtari, Fatemeh; Paolini, Brielle M.; Burdette, Jonathan H.; Marsh, Anthony P.; Rejeski, W. Jack; Laurienti, Paul J.

    2016-01-01

    Objective The purpose of this study is to investigate if structural brain phenotypes can be used to predict weight loss success following behavioral interventions in older adults that are overweight or obese and have cardiometabolic dysfunction. Methods A support vector machine (SVM) with a repeated random subsampling validation approach was used to classify participants into the upper and lower halves of the weight loss distribution following 18 months of a weight loss intervention. Predictions were based on baseline brain gray matter (GM) and white matter (WM) volume from 52 individuals that completed the intervention and a magnetic resonance imaging session. Results The SVM resulted in an average classification accuracy of 72.62 % based on GM and WM volume. A receiver operating characteristic analysis indicated that classification performance was robust based on an area under the curve of 0.82. Conclusions Our findings suggest that baseline brain structure is able to predict weight loss success following 18 months of treatment. The identification of brain structure as a predictor of successful weight loss is an innovative approach to identifying phenotypes for responsiveness to intensive lifestyle interventions. This phenotype could prove useful in future research focusing on the tailoring of treatment for weight loss. PMID:27804273

  6. The TMI Regenerative Solid Oxide Fuel Cell

    NASA Technical Reports Server (NTRS)

    Cable, Thomas L.; Ruhl, Robert C.; Petrik, Michael

    1996-01-01

    Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. Systems generally consist of photovoltaic solar arrays which operate (during sunlight cycles) to provide system power and regenerate fuel (hydrogen) via water electrolysis and (during dark cycles) fuel cells convert hydrogen into electricity. Common configurations use two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Reliability, power to weight and power to volume ratios could be greatly improved if both power production (fuel cells) and power storage (electrolysis) functions can be integrated into a single unit. The solid oxide fuel cell (SOFC) based design integrates fuel cell and electrolyzer functions and potentially simplifies system requirements. The integrated fuel cell/electrolyzer design also utilizes innovative gas storage concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H20 electrode (SOFC anode/electrolyzer cathode) materials for regenerative fuel cells. Tests have shown improved cell performance in both fuel and electrolysis modes in reversible fuel cell tests. Regenerative fuel cell efficiencies, ratio of power out (fuel cell mode) to power in (electrolyzer mode), improved from 50 percent using conventional electrode materials to over 80 percent. The new materials will allow a single SOFC system to operate as both the electolyzer and fuel cell. Preliminary system designs have also been developed to show the technical feasibility of using the design for space applications requiring high energy storage efficiencies and high specific energy. Small space systems also have potential for dual-use, terrestrial applications.

  7. A method for determining optimum phasing of a multiphase propulsion system for a single-stage vehicle with linearized inert weight

    NASA Technical Reports Server (NTRS)

    Martin, J. A.

    1974-01-01

    A general analytical treatment is presented of a single-stage vehicle with multiple propulsion phases. A closed-form solution for the cost and for the performance and a derivation of the optimal phasing of the propulsion are included. Linearized variations in the inert weight elements are included, and the function to be minimized can be selected. The derivation of optimal phasing results in a set of nonlinear algebraic equations for optimal fuel volumes, for which a solution method is outlined. Three specific example cases are analyzed: minimum gross lift-off weight, minimum inert weight, and a minimized general function for a two-phase vehicle. The results for the two-phase vehicle are applied to the dual-fuel rocket. Comparisons with single-fuel vehicles indicate that dual-fuel vehicles can have lower inert weight either by development of a dual-fuel engine or by parallel burning of separate engines from lift-off.

  8. Association between mean platelet volume and bone mineral density in patients with ankylosing spondylitis and diagnostic value of diffusion-weighted magnetic resonance imaging

    PubMed Central

    Resorlu, Hatice; Resorlu, Mustafa; Gokmen, Ferhat; Akbal, Ayla; Adam, Gurhan; Komurcu, Erkam; Goksel, Ferdi; Guven, Mustafa; Aras, Adem Bozkurt; Sariyildirim, Abdullah; Cevizci, Sibel

    2015-01-01

    [Purpose] The aim this study was to assess the relation between bone mineral density (BMD) and mean platelet volume (MPV) in ankylosing spondylitis (AS) patients, and evaluate the diagnostic role of the diffusion-weighted magnetic resonance imaging (MRI). [Subjects and Methods] Fifty patients diagnosed with AS were divided into two groups on the basis of BMD, a normal group (n=30) and an osteopenic (n=20) group. [Results] Duration of disease in the group with a normal BMD was 10.3±7.0 years, while it was 16.7±12.2 years in the osteopenia group. MPV was high in the osteopenia group, while no significant differences were observed between the groups in terms of apparent diffusion coefficient (ADC) and platelet distribution width (PDW). There was a positive correlation between MPV and duration of disease. Correlations between ADC value and the lumbar T score, femoral neck T score, and duration of disease were insignificant. A negative correlation was observed between BMD and disease duration. [Conclusion] Diffusion-weighted imaging provides valuable results in osteoporosis but is not a suitable technique for evaluating BMD in patients with AS because of the local and systemic inflammatory effects in the musculoskeletal system. The common pathophysiology of atherosclerosis and osteoporosis plays an important role in the negative correlation observed between MPV and BMD in patients with AS. PMID:25995574

  9. The Intermodal Bike: multi-modal integration of cycling mobility through product and process innovations in bicycle design.

    PubMed

    Tosi, Francesca; Belli, Alessandro; Rinaldi, Alessandra; Tucci, Grazia

    2012-01-01

    The paper presents the early results of the UE-FP7 project "The Intermodal Bike". The research aim is to provide a super-compactable, super-lightweight folding bicycle as a realistic solution to graft the cycling mode onto the root of the public or private transportation systems. The folding bikes now on the international market reach weighs between 12-15 kg, with a variable footprint but occupying -when compacted- an average volume of about 100 liters. To encourage the use of this vehicle and to extend it to a larger number of users with different characteristics, the research project has set its goal in increasing as possible compactness and light weight, creating a bicycle with a volume when compacted of 20 liters (reduction factor =5), with a shape of 48 × 36 × 12 cm and a weight of 5 kg. max., ensuring stability and improving vehicle usability and efficiency, during the ride and in the phase of bike folding. To achieve this goal ergonomic and usability tests have been carried out. The tests allowed to find a posture that would ensure efficiency and comfort in the ride to as many users as possible. Parallel tests were made on the vehicle usability in the urban transport system and intermodal. The need for light weight has required special studies on the optimization of the vehicle's architecture and research on super-lightweight materials.

  10. Phase behaviour of casein micelles and barley beta-glucan polymer molecules in dietary fibre-enriched dairy systems.

    PubMed

    Repin, Nikolay; Scanlon, Martin G; Fulcher, R Gary

    2012-07-01

    Enrichment of colloidal dairy systems with dietary fibre frequently causes quality defects because of phase separation. We investigate phase separation in skimmed milk enriched with Glucagel (a commercial product made from barley that is predominantly comprised of the polysaccharide β-glucan). The driving force for phase separation was depletion flocculation of casein micelles in the presence of molecules of the polysaccharide. Depending on the volume fraction of casein micelles and the concentration of Glucagel, the stable system phase separated either as a transient gel or as a sedimented system. The rate at which phase separation progressed also depended on the volume fraction of casein micelles and the concentration of Glucagel. To confirm the role of depletion flocculation in the phase separation process, enzymatic reduction in the molecular weight of β-glucan was shown to limit the range of attraction between micelles and allow the stable phase to exist at a higher β-glucan concentration for any given volume fraction of casein micelles. These phase diagrams will be useful to dairy product manufacturers striving to improve the nutrient profile of their products while avoiding product quality impairment. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Study of solar array switching power management technology for space power system

    NASA Technical Reports Server (NTRS)

    Cassinelli, J. E.

    1982-01-01

    This report documents work performed on the Solar Array Switching Power Management Study. Mission characteristics for three missions were defined to the depth necessary to determine their power management requirements. Solar array switching concepts were identified that could safisfy the mission requirements. These switching concepts were compared with a conventional buck regulator system on the basis of cost, weight and volume, reliability, efficiency and thermal control. For the missions reviewed, solar array switching provided significant advantages in all areas of comparison.

  12. Chicago Monostatic Acoustic Vortex Sensing System. Volume II. Decay of B-707 and DC-8 Vortices.

    DTIC Science & Technology

    1981-09-01

    wake vortex strength measured with the Monostatic Acoustic Vortex Sensing System (MAVSS). The data might be used to refine the wake ... analysis . The correlation of vortex strength with aircraft weight is examined statist icalIy. A primary issue addressed is whether there are any differences ...of the vortices at the antenna positions. The velocity profiles (v(r’), where r’ is the vortex radius) are used to determine the average vort

  13. Phase 1 of the near term hybrid passenger vehicle development program. Appendix B: Trade-off studies, volume 1

    NASA Technical Reports Server (NTRS)

    Traversi, M.; Piccolo, R.

    1980-01-01

    Tradeoff study activities and the analysis process used are described with emphasis on (1) review of the alternatives; (2) vehicle architecture; and (3) evaluation of the propulsion system alternatives; interim results are presented for the basic hybrid vehicle characterization; vehicle scheme development; propulsion system power and transmission ratios; vehicle weight; energy consumption and emissions; performance; production costs; reliability, availability and maintainability; life cycle costs, and operational quality. The final vehicle conceptual design is examined.

  14. Fuel cell technology program

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A program to advance the technology for a cost-effective hydrogen/oxygen fuel cell system for future manned spacecraft is discussed. The evaluation of base line design concepts and the development of product improvements in the areas of life, power, specific weight and volume, versatility of operation, field maintenance and thermal control were conducted from the material and component level through the fabrication and test of an engineering model of the fuel cell system. The program was to be accomplished in a 13 month period.

  15. Study of solar array switching power management technology for space power system

    NASA Technical Reports Server (NTRS)

    Cassinelli, J. E.

    1982-01-01

    This report documents work performed on the Solar Array Switching Power Management Study. Mission characteristics for three missions were defined to the depth necessary to determine their power management requirements. Solar array switching concepts which could satisfy the mission requirements were identified. The switching concepts were compared with a conventional buck regulator system for cost, weight and volume, reliability, efficiency and thermal control. Solar array switching provided significant advantages in all areas of comparison for the reviewed missions.

  16. AAAIC '88 - Aerospace Applications of Artificial Intelligence; Proceedings of the Fourth Annual Conference, Dayton, OH, Oct. 25-27, 1988. Volumes 1 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, J.R.; Netrologic, Inc., San Diego, CA)

    1988-01-01

    Topics presented include integrating neural networks and expert systems, neural networks and signal processing, machine learning, cognition and avionics applications, artificial intelligence and man-machine interface issues, real time expert systems, artificial intelligence, and engineering applications. Also considered are advanced problem solving techniques, combinational optimization for scheduling and resource control, data fusion/sensor fusion, back propagation with momentum, shared weights and recurrency, automatic target recognition, cybernetics, optical neural networks.

  17. Phase-Change Heat-Storage Module

    NASA Technical Reports Server (NTRS)

    Mulligan, James C.

    1989-01-01

    Heat-storage module accommodates momentary heating or cooling overload in pumped-liquid heat-transfer system. Large heat-storage capacity of module provided by heat of fusion of material that freezes at or near temperature desired to maintain object to be heated or cooled. Module involves relatively small penalties in weight, cost, and size and more than compensates by enabling design of rest of system to handle only average load. Latent heat of fusion of phase-change material provides large heat-storage capacity in small volume.

  18. Proceedings of the Annual Space Surveillance Workshop (12th) Held in Lexington, Massachusetts on 5-7 April 1994. Volume 1

    DTIC Science & Technology

    1994-04-07

    Systems Co. T. Jakab, D. Mooney and S. Smith - Contraves Inc. R. Richmond - Rockwell Power Systems Hyperspectral Imaging of Near-Earth Space Objects at...its greatest asset. - This flexibility makes it possible to employ the whole weight of the available aerospace power against selected areas in turn...redundant equipment to prevent loss of capability in the event of single component failures. Failover of equipment will be automatic and transparent

  19. Firefighter's compressed air breathing system pressure vessel development program

    NASA Technical Reports Server (NTRS)

    Beck, E. J.

    1974-01-01

    The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, Thomas J.; Myjak, Mitchell J.

    At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives tomore » the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.« less

  1. Comparison of dose volume parameters evaluated using three forward planning – optimization techniques in cervical cancer brachytherapy involving two applicators

    PubMed Central

    Basu-Roy, Somapriya; Kar, Sanjay Kumar; Das, Sounik; Lahiri, Annesha

    2017-01-01

    Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and methods We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times (‘no optimization’), ‘manual dwell weight/times’, and ‘graphical’. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D2cc) rectum and rectal point etc.; D2cc, minimum, maximum, median, and average dose to sigmoid colon; D2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced. PMID:29204164

  2. Integrated orbital servicing study for low-cost payload programs. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Derocher, W. L., Jr.

    1975-01-01

    Various operating methodologies to achieve low-cost space operations were investigated as part of the Space Transportation System (STS) planning. The emphasis was to show that the development investment, initial fleet costs, and supporting facilities for the STS could be effectively offset by exploiting the capabilities of the STS to satisfy mission requirements and reduce the cost of payload programs. The following major conclusions were reached: (1) the development of an on-orbit servicer maintenance system is compatible with many spacecraft programs and is recommended as the most cost-effective system, (2) spacecraft can be designed to be serviceable with acceptable design, weight, volume, and cost effects, (3) use of on-orbit servicing over a 12 year period results in savings ranging between four and nine billion dollars, (4) the pivoting arm on-orbit servicer was selected and a preliminary design was prepared, (5) orbital maintenance has no significant impact on the STS.

  3. Phase behaviour of oat β-glucan/sodium caseinate mixtures varying in molecular weight.

    PubMed

    Agbenorhevi, Jacob K; Kontogiorgos, Vassilis; Kasapis, Stefan

    2013-05-01

    The isothermal phase behaviour at 5 °C of mixtures of sodium caseinate and oat β-glucan isolates varying in molecular weight (MW) was investigated by means of phase diagram construction, rheometry, fluorescence microscopy and electrophoresis. Phase diagrams indicated that the compatibility of the β-glucan/sodium caseinate system increases as β-glucan MW decreases. Images of mixtures taken at various biopolymer concentrations revealed phase separated domains. Results also revealed that at the state of thermodynamic equilibrium, lower MW samples yielded considerable viscosity in the mixture. At equivalent hydrodynamic volume of β-glucan in the mixtures, samples varying in molecular weight exhibited similar flow behaviour. A deviation dependent on the protein concentration was observed for the high MW sample in the concentrated regime due to the size of β-glucan aggregates formed. Results demonstrate that by controlling the structural features of β-glucan in mixtures with sodium caseinate, informed manipulation of rheological properties in these systems can be achieved. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Numeric and volumetric changes in Leydig cells during aging of rats.

    PubMed

    Neves, Bruno Vinicius Duarte; Lorenzini, Fernando; Veronez, Djanira; Miranda, Eduardo Pereira de; Neves, Gabriela Duarte; Fraga, Rogério de

    2017-10-01

    To analyze the effects of aging in rats on the nuclear volume, cytoplasmic volume, and total volume of Leydig cells, as well as their number. Seventy-two Wistar rats were divided into six subgroups of 12 rats, which underwent right orchiectomy at 3, 6, 9, 12, 18, and 24 months of age. The weight and volume of the resected testicles were assessed. A stereological study of Leydig cells was conducted, which included measurements of cell number and nuclear, cytoplasmic, and total cell volumes. The weight and volume of the resected testicles showed reductions with age. Only the subgroup composed of 24-month old rats showed a decrease in the nuclear volume of Leydig cells. Significant reductions in the cytoplasmic volume and total volume of Leydig cells were observed in 18- and 24-month old rats. The number of Leydig cells did not vary significantly with age. Aging in rats resulted in reduction of the nuclear, cytoplasmic, and total cell volumes of Leydig cells. There was no change in the total number of these cells during aging.

  5. System concept for a moderate cost Large Deployable Reflector (LDR)

    NASA Technical Reports Server (NTRS)

    Swanson, P. N.; Breckinridge, J. B.; Diner, A.; Freeland, R. E.; Irace, W. R.; Mcelroy, P. M.; Meinel, A. B.; Tolivar, A. F.

    1986-01-01

    A study was carried out at JPL during the first quarter of 1985 to develop a system concept for NASA's LDR. Major features of the concept are a four-mirror, two-stage optical system; a lightweight structural composite segmented primary reflector; and a deployable truss backup structure with integral thermal shield. The two-stage optics uses active figure control at the quaternary reflector located at the primary reflector exit pupil, allowing the large primary to be passive. The lightweight composite reflector panels limit the short-wavelength operation to approximately 30 microns but reduce the total primary reflector weight by a factor of 3 to 4 over competing technologies. On-orbit thermal analysis indicates a primary reflector equilibrium temperature of less than 200 K with a maximum gradient of about 5 C across the 20-m aperture. Weight and volume estimates are consistent with a single Shuttle launch, and are based on Space Station assembly and checkout.

  6. Monolithic Microwave Integrated Circuit (MMIC) technology for space communications applications

    NASA Technical Reports Server (NTRS)

    Connolly, Denis J.; Bhasin, Kul B.; Romanofsky, Robert R.

    1987-01-01

    Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.

  7. Monolithic Microwave Integrated Circuit (MMIC) technology for space communications applications

    NASA Technical Reports Server (NTRS)

    Connolly, Denis J.; Bhasin, Kul B.; Romanofsky, Robert R.

    1987-01-01

    Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMICs to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMICs is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.

  8. Extended duration Orbiter life support definition

    NASA Technical Reports Server (NTRS)

    Kleiner, G. N.; Thompson, C. D.

    1978-01-01

    Extending the baseline seven-day Orbiter mission to 30 days or longer and operating with a solar power module as the primary source for electrical power requires changes to the existing environmental control and life support (ECLS) system. The existing ECLS system imposes penalties on longer missions which limit the Orbiter capabilities and changes are required to enhance overall mission objectives. Some of these penalties are: large quantities of expendables, the need to dump or store large quantities of waste material, the need to schedule fuel cell operation, and a high landing weight penalty. This paper presents the study ground rules and examines the limitations of the present ECLS system against Extended Duration Orbiter mission requirements. Alternate methods of accomplishing ECLS functions for the Extended Duration Orbiter are discussed. The overall impact of integrating these options into the Orbiter are evaluated and significant Orbiter weight and volume savings with the recommended approaches are described.

  9. Geospatial cross-correlation analysis of Oklahoma earthquakes and saltwater disposal volume 2011 - 2016

    NASA Astrophysics Data System (ADS)

    Pollyea, R.; Mohammadi, N.; Taylor, J. E.

    2017-12-01

    The annual earthquake rate in Oklahoma increased dramatically between 2009 and 2016, owing in large part to the rapid proliferation of salt water disposal wells associated with unconventional oil and gas recovery. This study presents a geospatial analysis of earthquake occurrence and SWD injection volume within a 68,420 km2 area in north-central Oklahoma between 2011 and 2016. The spatial co-variability of earthquake occurrence and SWD injection volume is analyzed for each year of the study by calculating the geographic centroid for both earthquake epicenter and volume-weighted well location. In addition, the spatial cross correlation between earthquake occurrence and SWD volume is quantified by calculating the cross semivariogram annually for a 9.6 km × 9.6 km (6 mi × 6 mi) grid over the study area. Results from these analyses suggest that the relationship between volume-weighted well centroids and earthquake centroids generally follow pressure diffusion space-time scaling, and the volume-weighted well centroid predicts the geographic earthquake centroid within a 1σ radius of gyration. The cross semivariogram calculations show that SWD injection volume and earthquake occurrence are spatially cross correlated between 2014 and 2016. These results also show that the strength of cross correlation decreased from 2015 to 2016; however, the cross correlation length scale remains unchanged at 125 km. This suggests that earthquake mitigation efforts have been moderately successful in decreasing the strength of cross correlation between SWD volume and earthquake occurrence near-field, but the far-field contribution of SWD injection volume to earthquake occurrence remains unaffected.

  10. Forensic postmortem computed tomography: volumetric measurement of the heart and liver.

    PubMed

    Jakobsen, Lykke Schrøder; Lundemose, Sissel; Banner, Jytte; Lynnerup, Niels; Jacobsen, Christina

    2016-12-01

    The purpose of this study was to investigate the utility of postmortem computed tomography (PMCT) images in estimating organ sizes and to examine the use of the cardiothoracic ratio (CTR). We included 45 individuals (19 females), who underwent a medico-legal autopsy. Using the computer software program Mimics ® , we determined in situ heart and liver volumes derived from linear measurements (width, height and depth) on a whole body PMCT-scan, and compared the volumes with ex vivo volumes derived by CT-scan of the eviscerated heart and liver. The ex vivo volumes were also compared with the organ weights. Further, we compared the CTR with the ex vivo heart volume and a heart weight-ratio (HWR). Intra- and inter-observer analyses were performed. We found no correlation between the in situ and ex vivo volumes of the heart and liver. However, a highly significant correlation was found between the ex vivo volumes and weights of the heart and liver. No correlations between CTR and the ex vivo heart volume nor with HWR was found. Concerning cardiomegaly, we found no agreement between the CTR and HWR. The intra- and inter-observer analyses showed no significant differences. Noninvasive in situ PMCT methods for organ measuring, as performed in this study, are not useful tools in forensic pathology. The best method to estimate organ volume is a CT-scan of the eviscerated organ. PMCT-determined CTR seems to be useless for ascertaining cardiomegaly, as it neither correlated with the ex vivo heart volume nor with the HWR.

  11. Dense modifiable interconnections utilizing photorefractive volume holograms

    NASA Astrophysics Data System (ADS)

    Psaltis, Demetri; Qiao, Yong

    1990-11-01

    This report describes an experimental two-layer optical neural network built at Caltech. The system uses photorefractive volume holograms to implement dense, modifiable synaptic interconnections and liquid crystal light valves (LCVS) to perform nonlinear thresholding operations. Kanerva's Sparse, Distributed Memory was implemented using this network and its ability to recognize handwritten character-alphabet (A-Z) has been demonstrated experimentally. According to Kanerva's model, the first layer has fixed, random weights of interconnections and the second layer is trained by sum-of-outer-products rule. After training, the recognition rates of the network on the training set (104 patterns) and test set (520 patterns) are 100 and 50 percent, respectively.

  12. Weight, volume, and physical properties of major hardwood species in the Southern Appalachian mountains

    Treesearch

    Alexander III Clark; James G. Schroeder

    1985-01-01

    The weight, volume, and physical properties of trees 1 to 20 inches d.h.h. were determined for basswood, blackgum (upland), red maple,yellow-poplar, white oak, sweet birch, black locust, hickory, black oak, chestnut oak, northern red oak, scarlet oak, and white oak in the Southern Appalachian Mountains. Hard hardwoods, soft hardwoods, and individual species equations...

  13. Weight, Volume, and Moisture Content of Sawdust from Selected Southern Species

    Treesearch

    W. S. Thompson; W. N. Darwin

    1968-01-01

    A study of the weight-volume relationships and moisture contents of sawdust from important hardwoods of the Mississippi River bottom lands was recently made by Mississippi State University in cooperation with the Southern Forest Experiment Station. (Sawdust presently is used to a limited extent in the manufacture of wood pulp, and a rise in consumption by this and...

  14. Soil bulk density and soil moisture calculated with a FORTRAN 77 program.

    Treesearch

    G.L. Starr; J.M. Geist

    1988-01-01

    This paper presents an improved version of BDEN, an interactive computer program written in FORTRAN 77 that will calculate soil bulk density and moisture percentage by weight and volume. Calculations allow for deducting coarse fragment weight and volume. The program will also summarize the resulting data by giving the mean, standard deviation, and 95-percent confidence...

  15. Merchantable Volume and Weights of Mahoe in Puerto Rican Plantations

    Treesearch

    John K. Francis

    1989-01-01

    Mahoe (Hibiscus elatus Sw.), a fast-growing tree whose wood is considered valuable, is planted and managed primarily in the West Indies. Until now, volume and weight tables have not been available for the species. Data used in this paper were collected from 50 felled trees in a range of sizes from plantations across Puerto Rico. Using linear...

  16. Intravenous Renal Cell Transplantation for Polycystic Kidney Disease

    DTIC Science & Technology

    2014-06-01

    to measure serum creatinine. 5b. urine collection twice each month for measurements of protein and creatinine ratios Task 6. Intravital imaging...volume, renal fibrosis (quantified on trichrome stained sections), albuminuria, blood urea nitrogen (BUN) and kidney weight were significantly...IRCT markedly reduced cyst volume, renal fibrosis, albuminuria, blood urea nitrogen and kidney weights in treated rats, as compared to PCK rats

  17. Individual Tree Biomass Models for Plantation Grown American Sycamore

    Treesearch

    Regan B. Willson; Bryce E. Schlaegel; Harvey E. Kennedy

    1982-01-01

    Individual tree volume and green and dry weight equations are derived for American sycamore from a 5-year-old plantation in southeast Arkansas. Two trees have been destructively sampled each year from each of 20 plots. Observations from 168 trees are used to predict tree weight and volume as a function of dbh, total height, age, and initial number of trees. Separate...

  18. Photo series for quantifying natural forest residues: southern Cascades, northern Sierra Nevada

    Treesearch

    Kenneth S. Blonski; John L. Schramel

    1981-01-01

    A total of 56 photographs shows different levels of natural fuel loadings for selected size classes in seven forest types of the southern Cascade and northern Sierra-Nevada ranges. Data provided with each photo include size, weight, volumes, residue depths, and percent of ground coverage. Stand information includes sizes, weights, and volumes of the trees sampled for...

  19. Deaf Children's Judgments on Conservation Problems of Liquid, Matter, Weight and Volume: A Pilot Study.

    ERIC Educational Resources Information Center

    Rittenhouse, Robert K.

    Twenty-four profoundly deaf children (7 to 13 years old) from a residential school were presented with conservation problems of liquid, matter, weight, and volume. Analyses of variance showed that age was significant beyond the .01 level and type of task (conservation) at the .25 level. No significant sex effect was found. Differences among means…

  20. Computer program to perform cost and weight analysis of transport aircraft. Volume 2: Technical volume

    NASA Technical Reports Server (NTRS)

    1973-01-01

    An improved method for estimating aircraft weight and cost using a unique and fundamental approach was developed. The results of this study were integrated into a comprehensive digital computer program, which is intended for use at the preliminary design stage of aircraft development. The program provides a means of computing absolute values for weight and cost, and enables the user to perform trade studies with a sensitivity to detail design and overall structural arrangement. Both batch and interactive graphics modes of program operation are available.

  1. The use of computed tomography for the estimation of DIEP flap weights in breast reconstruction: a simple mathematical formula.

    PubMed

    Nanidis, Theodore G; Ridha, Hyder; Jallali, Navid

    2014-10-01

    Estimation of the volume of abdominal tissue is desirable when planning autologous abdominal based breast reconstruction. However, this can be difficult clinically. The aim of this study was to develop a simple, yet reliable method of calculating the deep inferior epigastric artery perforator flap weight using the routine preoperative computed tomography angiogram (CTA) scan. Our mathematical formula is based on the shape of a DIEP flap resembling that of an isosceles triangular prism. Thus its volume can be calculated with a standard mathematical formula. Using bony landmarks three measurements were acquired from the CTA scan to calculate the flap weight. This was then compared to the actual flap weight harvested in both a retrospective feasibility and prospective study. In the retrospective group 17 DIEP flaps in 17 patients were analyzed. Average predicted flap weight was 667 g (range 293-1254). The average actual flap weight was 657 g (range 300-1290) giving an average percentage error of 6.8% (p-value for weight difference 0.53). In the prospective group 15 DIEP flaps in 15 patients were analyzed. Average predicted flap weight was 618 g (range 320-925). The average actual flap weight was 624 g (range 356-970) giving an average percentage error of 6.38% (p-value for weight difference 0.57). This formula is a quick, reliable and accurate way of estimating the volume of abdominal tissue using the preoperative CTA scan. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Adaptive changes in pancreas post Roux-en-Y gastric bypass induced weight loss.

    PubMed

    Lautenbach, A; Wernecke, M; Riedel, N; Veigel, J; Yamamura, J; Keller, S; Jung, R; Busch, P; Mann, O; Knop, F K; Holst, J J; Meier, J J; Aberle, J

    2018-05-16

    Obesity has been shown to trigger adaptive increases in pancreas parenchymal and fat volume. Consecutively, pancreatic steatosis may lead to beta-cell dysfunction. However, it is not known, whether the pancreatic tissue components decrease with weight loss and pancreatic steatosis is reversible following RYGB. Therefore, the objective of the study was to investigate the effects of RYGB-induced weight loss on pancreatic volume and glucose homeostasis. 11 patients were recruited in the Obesity Centre of the University Medical Centre Hamburg-Eppendorf. Before and 6 months after RYGB, total GLP-1 levels were measured during OGTT. To assess changes in visceral adipose tissue and pancreatic volume, MRI was performed. Measures of glucose homeostasis and insulin indices were assessed. Fractional beta-cell area was estimated by correlation with the C-peptide-to-glucose ratio, beta-cell mass was calculated by the product of beta-cell area and pancreas parenchymal weight. Pancreas volume decreased from 83.8 (75.7-92.0) to 70.5 (58.8-82.3) cm 3 [mean (95% CI), p=0.001]. The decrease in total volume was associated with a significant decrease in fat volume. Fasting insulin and C-peptide were lower post RYGB. HOMA-IR levels decreased, whereas insulin sensitivity increased (p=0.03). This was consistent with a reduction in the estimated beta-cell area and mass. Following RYGB, pancreatic volume and steatosis adaptively decreased to "normal" levels with accompanying improvement in glucose homeostasis. Moreover, obesity-driven beta-cell expansion seems to be reversible, however future studies must define a method to more accurately estimate functional beta-cell mass to increase our understanding of glucose homeostasis after RYGB. This article is protected by copyright. All rights reserved.

  3. Estimation of the sensitive volume for gravitational-wave source populations using weighted Monte Carlo integration

    NASA Astrophysics Data System (ADS)

    Tiwari, Vaibhav

    2018-07-01

    The population analysis and estimation of merger rates of compact binaries is one of the important topics in gravitational wave astronomy. The primary ingredient in these analyses is the population-averaged sensitive volume. Typically, sensitive volume, of a given search to a given simulated source population, is estimated by drawing signals from the population model and adding them to the detector data as injections. Subsequently injections, which are simulated gravitational waveforms, are searched for by the search pipelines and their signal-to-noise ratio (SNR) is determined. Sensitive volume is estimated, by using Monte-Carlo (MC) integration, from the total number of injections added to the data, the number of injections that cross a chosen threshold on SNR and the astrophysical volume in which the injections are placed. So far, only fixed population models have been used in the estimation of binary black holes (BBH) merger rates. However, as the scope of population analysis broaden in terms of the methodologies and source properties considered, due to an increase in the number of observed gravitational wave (GW) signals, the procedure will need to be repeated multiple times at a large computational cost. In this letter we address the problem by performing a weighted MC integration. We show how a single set of generic injections can be weighted to estimate the sensitive volume for multiple population models; thereby greatly reducing the computational cost. The weights in this MC integral are the ratios of the output probabilities, determined by the population model and standard cosmology, and the injection probability, determined by the distribution function of the generic injections. Unlike analytical/semi-analytical methods, which usually estimate sensitive volume using single detector sensitivity, the method is accurate within statistical errors, comes at no added cost and requires minimal computational resources.

  4. Regional body volumes, BMI, waist circumference, and percentage fat in severely obese adults.

    PubMed

    Wang, Jack; Gallagher, Dympna; Thornton, John C; Yu, Wen; Weil, Rich; Kovac, Betty; Pi-Sunyer, F Xavier

    2007-11-01

    This study presents total body volume (TBV) and regional body volume, and their relationships with widely used body composition indices [BMI, waist circumference (WC), and percentage body fat (% fat)] in severely obese adults (BMI >or=35 kg/m(2)). We measured TBV, trunk volume (TV), arm volume (AV), leg volume (LV), and WC and estimated % fat in 32 severely obese persons with BMI 36 to 62 kg/m(2) (23 women; age, 19 to 65 years; weight, 91 to 182 kg) and in 58 persons with BMI <35 kg/m(2) (28 women; age, 18 to 83 years; weight, 48 to 102 kg) using a newly validated 3-day photonic image scanner (3DPS, Model C9036-02, Hamamatsu Co., Japan) and calculated TV/TBV, AV/TBV, and LV/TBV. Men had significantly larger TBV and higher TV/TBV and AV/TBV, but significantly lower LV/TBV than women, independently of BMI. TV/TBV increased while AV/TBV and LV/TBV decreased with increasing BMI, WC, and % fat, and the rate of increase in TV/TBV per % fat was significantly greater in severely obese individuals than in individuals with BMI <35 kg/m(2). The relationships for TBV with % fat were much lower than with BMI or WC. Body volume gains were mainly in the trunk region in adults, irrespective of sex or BMI. For a given BMI, WC, or % fat, men had a significantly larger TV than women. The implication is that men could have higher health risks due to having higher trunk body weight as a proportion of total body weight compared with severely obese or less severely obese women.

  5. A simple orchidometric method for the preliminary assessment of maturity status in male cynomolgus monkeys (Macaca fascicularis) used for nonclinical safety studies.

    PubMed

    Ku, Warren W; Pagliusi, Frank; Foley, George; Roesler, Alfred; Zimmerman, Thomas

    2010-01-01

    The identification and use of mature male non-human primates in nonclinical toxicology studies could be important for evaluating candidate drugs for which the profile of toxicity may differ depending on sexual maturity. This investigation sought to establish operational criteria to complement the current standard of histological evaluation for defining sexual maturity in male cynomolgus monkeys (Macaca fascicularis) used for toxicology studies, and to identify a practical non-invasive measure to select mature males for study. Retrospectively, the relationships between body weight, testicular weight and testis histology were established in control males (n=126) used in previous toxicology studies. Prospectively, testicular volumes were measured in-life by orchidometry using comparative scrotal palpation (n=23 males used for study), then compared to testicular weights measured at necropsy. Consistent with previous literature, a weak relationship was observed between body weight and testicular weight. There was, however, a very good relationship between testicular weight and histological maturation level, which was based upon microscopic examination of testes, epididymides and prostates. Orchidometric measurement of testicular volume was found to be a reasonable predictor of testicular weight and served to rapidly select sexually mature males for study, and a total testicular volume (left and right combined) of >20 ml correlated with the histological appearance of maturity. Based upon this preliminary exploratory study, the initial simple measurement of testicular volume by orchidometry may provide a non-invasive alternative approach for assessing the sexual maturity of male cynomolgus monkeys in research colonies or during toxicology studies that will require more thorough validation. Copyright 2009 Elsevier Inc. All rights reserved.

  6. Flow-Control Unit For Nitrogen And Hydrogen Gases

    NASA Technical Reports Server (NTRS)

    Chang, B. J.; Novak, D. W.

    1990-01-01

    Gas-flow-control unit installed and removed as one piece replaces system that included nine separately serviced components. Unit controls and monitors flows of nitrogen and hydrogen gases. Designed for connection via fluid-interface manifold plate, reducing number of mechanical fluid-interface connections from 18 to 1. Unit provides increasing reliability, safety, and ease of maintenance, and for reducing weight, volume, and power consumption.

  7. Expendable second stage reusable space shuttle booster. Volume 4: Detail mass properties data

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Mass properties data are presented to describe the characteristics of an expendable second stage with a reusable space shuttle booster. The final mass characteristics of the vehicle configurations for three specified payloads are presented in terms of weight, center of gravity, and mass moments of inertia. Three basic subjects are the integrated vehicle system, the expendable second stage, and the booster modifications.

  8. Task-specific feature extraction and classification of fMRI volumes using a deep neural network initialized with a deep belief network: Evaluation using sensorimotor tasks

    PubMed Central

    Jang, Hojin; Plis, Sergey M.; Calhoun, Vince D.; Lee, Jong-Hwan

    2016-01-01

    Feedforward deep neural networks (DNN), artificial neural networks with multiple hidden layers, have recently demonstrated a record-breaking performance in multiple areas of applications in computer vision and speech processing. Following the success, DNNs have been applied to neuroimaging modalities including functional/structural magnetic resonance imaging (MRI) and positron-emission tomography data. However, no study has explicitly applied DNNs to 3D whole-brain fMRI volumes and thereby extracted hidden volumetric representations of fMRI that are discriminative for a task performed as the fMRI volume was acquired. Our study applied fully connected feedforward DNN to fMRI volumes collected in four sensorimotor tasks (i.e., left-hand clenching, right-hand clenching, auditory attention, and visual stimulus) undertaken by 12 healthy participants. Using a leave-one-subject-out cross-validation scheme, a restricted Boltzmann machine-based deep belief network was pretrained and used to initialize weights of the DNN. The pretrained DNN was fine-tuned while systematically controlling weight-sparsity levels across hidden layers. Optimal weight-sparsity levels were determined from a minimum validation error rate of fMRI volume classification. Minimum error rates (mean ± standard deviation; %) of 6.9 (± 3.8) were obtained from the three-layer DNN with the sparsest condition of weights across the three hidden layers. These error rates were even lower than the error rates from the single-layer network (9.4 ± 4.6) and the two-layer network (7.4 ± 4.1). The estimated DNN weights showed spatial patterns that are remarkably task-specific, particularly in the higher layers. The output values of the third hidden layer represented distinct patterns/codes of the 3D whole-brain fMRI volume and encoded the information of the tasks as evaluated from representational similarity analysis. Our reported findings show the ability of the DNN to classify a single fMRI volume based on the extraction of hidden representations of fMRI volumes associated with tasks across multiple hidden layers. Our study may be beneficial to the automatic classification/diagnosis of neuropsychiatric and neurological diseases and prediction of disease severity and recovery in (pre-) clinical settings using fMRI volumes without requiring an estimation of activation patterns or ad hoc statistical evaluation. PMID:27079534

  9. Task-specific feature extraction and classification of fMRI volumes using a deep neural network initialized with a deep belief network: Evaluation using sensorimotor tasks.

    PubMed

    Jang, Hojin; Plis, Sergey M; Calhoun, Vince D; Lee, Jong-Hwan

    2017-01-15

    Feedforward deep neural networks (DNNs), artificial neural networks with multiple hidden layers, have recently demonstrated a record-breaking performance in multiple areas of applications in computer vision and speech processing. Following the success, DNNs have been applied to neuroimaging modalities including functional/structural magnetic resonance imaging (MRI) and positron-emission tomography data. However, no study has explicitly applied DNNs to 3D whole-brain fMRI volumes and thereby extracted hidden volumetric representations of fMRI that are discriminative for a task performed as the fMRI volume was acquired. Our study applied fully connected feedforward DNN to fMRI volumes collected in four sensorimotor tasks (i.e., left-hand clenching, right-hand clenching, auditory attention, and visual stimulus) undertaken by 12 healthy participants. Using a leave-one-subject-out cross-validation scheme, a restricted Boltzmann machine-based deep belief network was pretrained and used to initialize weights of the DNN. The pretrained DNN was fine-tuned while systematically controlling weight-sparsity levels across hidden layers. Optimal weight-sparsity levels were determined from a minimum validation error rate of fMRI volume classification. Minimum error rates (mean±standard deviation; %) of 6.9 (±3.8) were obtained from the three-layer DNN with the sparsest condition of weights across the three hidden layers. These error rates were even lower than the error rates from the single-layer network (9.4±4.6) and the two-layer network (7.4±4.1). The estimated DNN weights showed spatial patterns that are remarkably task-specific, particularly in the higher layers. The output values of the third hidden layer represented distinct patterns/codes of the 3D whole-brain fMRI volume and encoded the information of the tasks as evaluated from representational similarity analysis. Our reported findings show the ability of the DNN to classify a single fMRI volume based on the extraction of hidden representations of fMRI volumes associated with tasks across multiple hidden layers. Our study may be beneficial to the automatic classification/diagnosis of neuropsychiatric and neurological diseases and prediction of disease severity and recovery in (pre-) clinical settings using fMRI volumes without requiring an estimation of activation patterns or ad hoc statistical evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Design of an ultra-thin dual band infrared system

    NASA Astrophysics Data System (ADS)

    Du, Ke; Cheng, Xuemin; Lv, Qichao; Hu, YiFei

    2014-11-01

    The ultra-thin imaging system using reflective multiple-fold structure has smaller volume and less weight while maintaining high resolution compared with conventional optical systems. The multi-folded approach can significantly extend focal distance within wide spectral range without incurring chromatic aberrations. In this paper, we present a dual infrared imaging system of four-folded reflection with two air-spaced concentric reflective surfaces. The dual brand IR system has 107mm effective focal length, 0.7NA, +/-4° FOV, and 50mm effective aperture with 80mm outer diameter into a 25mm total thickness, which spectral response is 3~12μm.

  11. Shuttle cryogenics supply system. Optimization study. Volume 5 B-4: Programmers manual for space shuttle orbit injection analysis (SOPSA)

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A computer program for space shuttle orbit injection propulsion system analysis (SOPSA) is described to show the operational characteristics and the computer system requirements. The program was developed as an analytical tool to aid in the preliminary design of propellant feed systems for the space shuttle orbiter main engines. The primary purpose of the program is to evaluate the propellant tank ullage pressure requirements imposed by the need to accelerate propellants rapidly during the engine start sequence. The SOPSA program will generate parametric feed system pressure histories and weight data for a range of nominal feedline sizes.

  12. The Relationship between Volume Conservation and a Volume Algorithm for a Rectangular Parallelepiped.

    ERIC Educational Resources Information Center

    Feghali, Issa Nehme

    This study was designed to investigate the relationship between the level of conservation of displaced volume and the degree to which sixth-grade children learn the volume algorithm of a cuboid, namely, volume equals weight times length times height. The problem chosen is based on an apparent discrepancy between the present school programs and…

  13. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    PubMed

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  14. Understanding the heterogeneity in volume overload and fluid distribution in decompensated heart failure is key to optimal volume management: role for blood volume quantitation.

    PubMed

    Miller, Wayne L; Mullan, Brian P

    2014-06-01

    This study sought to quantitate total blood volume (TBV) in patients hospitalized for decompensated chronic heart failure (DCHF) and to determine the extent of volume overload, and the magnitude and distribution of blood volume and body water changes following diuretic therapy. The accurate assessment and management of volume overload in patients with DCHF remains problematic. TBV was measured by a radiolabeled-albumin dilution technique with intravascular volume, pre-to-post-diuretic therapy, evaluated at hospital admission and at discharge. Change in body weight in relation to quantitated TBV was used to determine interstitial volume contribution to total fluid loss. Twenty-six patients were prospectively evaluated. Two patients had normal TBV at admission. Twenty-four patients were hypervolemic with TBV (7.4 ± 1.6 liters) increased by +39 ± 22% (range, +9.5% to +107%) above the expected normal volume. With diuresis, TBV decreased marginally (+30 ± 16%). Body weight declined by 6.9 ± 5.2 kg, and fluid intake/fluid output was a net negative 8.4 ± 5.2 liters. Interstitial compartment fluid loss was calculated at 6.2 ± 4.0 liters, accounting for 85 ± 15% of the total fluid reduction. TBV analysis demonstrated a wide range in the extent of intravascular overload. Dismissal measurements revealed marginally reduced intravascular volume post-diuretic therapy despite large reductions in body weight. Mobilization of interstitial fluid to the intravascular compartment with diuresis accounted for this disparity. Intravascular volume, however, remained increased at dismissal. The extent, composition, and distribution of volume overload are highly variable in DCHF, and this variability needs to be taken into account in the approach to individualized therapy. TBV quantitation, particularly serial measurements, can facilitate informed volume management with respect to a goal of treating to euvolemia. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Changes in infant disposable diaper weights at selected intervals post-wetting.

    PubMed

    Carlisle, Joan; Moore, Amanda; Cooper, Alyssa; Henderson, Terri; Mayfield, Debbie; Taylor, Randa; Thomas, Jennifer; Van Fleet, Laduska; Askanazi, David; Fineberg, Naomi; Sun, Yanhui

    2012-01-01

    Pediatric acute care nurses questioned the practice of weighing disposable infant diapers immediately after voiding. This study asked the research question, "Does volume of saline, diaper configuration, and/or size of diaper statistically effect changes in diaper weights over time?" The method was an experimental, laboratory model. Pre-set volumes of saline were added to disposable diapers that were then left folded or unfolded. Each diaper was weighed immediately post-wetting and re-weighed at hourly intervals for seven hours. Data were analyzed using a repeated measures analysis of variance (RMANOVA) with balanced data (F-test). Diaper weight changes over time were statistically significant for all time points and for all volumes regardless of diaper size; however, the changes in weight were small and without clinical significance. It is appropriate to weigh diapers at the end of eight hours without risk of altering subsequent fluid management of patients in open-air, non-humidified environments. This practice has led to more efficient use of nurses' time with fewer interruptions for patients and families.

  16. Significance of Epicardial and Intrathoracic Adipose Tissue Volume among Type 1 Diabetes Patients in the DCCT/EDIC: A Pilot Study

    PubMed Central

    Budoff, Matthew J.

    2016-01-01

    Introduction Type 1 diabetes (T1DM) patients are at increased risk of coronary artery disease (CAD). This pilot study sought to evaluate the relationship between epicardial adipose tissue (EAT) and intra-thoracic adipose tissue (IAT) volumes and cardio-metabolic risk factors in T1DM. Method EAT/IAT volumes in 100 patients, underwent non-contrast cardiac computed tomography in the Diabetes Control and Complications Trial /Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) study were measured by a certified reader. Fat was defined as pixels’ density of -30 to -190 Hounsfield Unit. The associations were assessed using–Pearson partial correlation and linear regression models adjusted for gender and age with inverse probability sample weighting. Results The weighted mean age was 43 years (range 32–57) and 53% were male. Adjusted for gender, Pearson correlation analysis showed a significant correlation between age and EAT/IAT volumes (both p<0.001). After adjusting for gender and age, participants with greater BMI, higher waist to hip ratio (WTH), higher weighted HbA1c, elevated triglyceride level, and a history of albumin excretion rate of equal or greater than 300 mg/d (AER≥300) or end stage renal disease (ESRD) had significantly larger EAT/IAT volumes. Conclusion T1DM patients with greater BMI, WTH ratio, weighted HbA1c level, triglyceride level and AER≥300/ESRD had significantly larger EAT/IAT volumes. Larger sample size studies are recommended to evaluate independency. PMID:27459689

  17. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  18. Volumetric abnormalities in connectivity-based subregions of the thalamus in patients with chronic schizophrenia.

    PubMed

    Kim, Jae-Jin; Kim, Dae-Jin; Kim, Tae-Gyun; Seok, Jeong-Ho; Chun, Ji Won; Oh, Maeng-Keun; Park, Hae-Jeong

    2007-12-01

    The thalamus, which consists of multiple subnuclei, has been of particular interest in the study of schizophrenia. This study aimed to identify abnormalities in the connectivity-based subregions of the thalamus in patients with schizophrenia. Thalamic volume was measured by a manual tracing on superimposed images of T1-weighted and diffusion tensor images in 30 patients with schizophrenia and 22 normal volunteers. Cortical regional volumes automatically measured by a surface-based approach and thalamic subregional volumes measured by a connectivity-based technique were compared between the two groups and their correlations between the connected regions were calculated in each group. Volume reduction was observed in the bilateral orbitofrontal cortices and the left cingulate gyrus on the cortical side, whereas in subregions connected to the right orbitofrontal cortex and bilateral parietal cortices on the thalamic side. Significant volumetric correlations were identified between the right dorsal prefrontal cortex and its related thalamic subregion and between the left parietal cortex and its related thalamic subregion only in the normal group. Our results suggest that patients with schizophrenia have a structural deficit in the corticothalamic systems, especially in the orbitofrontal-thalamic system. Our findings may present evidence of corticothalamic connection problems in schizophrenia.

  19. Do body mass index and fat volume influence vocal quality, phonatory range, and aerodynamics in females?

    PubMed

    Barsties, Ben; Verfaillie, Rudi; Roy, Nelson; Maryn, Youri

    2013-01-01

    To analyze the impact of body weight and body fat volume on selected parameters of vocal quality, phonatory range, and aerodynamics in females. Based on measurements of body mass index in combination with body fat volume, 29 normophonic female subjects were classified as normal weight, underweight, and obese. Voice quality was investigated via auditory-perceptual ratings of breathiness, roughness, and overall dysphonia severity, via various acoustic measures and a multiparametric index. Phonatory range performance was examined using selected measures of the voice range profile and speech range profile. Measures of vocally relevant aerodynamics included vital capacity (i.e., VC), expected VC, phonation quotient, and maximum phonation time (i.e., MPT). Significant differences between the three weight groups were found across several measures of intensity, VC, MPT, and shimmer. As compared to the other groups, significantly higher values of maximum and minimum intensity levels, as well as sound pressure level during habitual running speech were observed for the obese group (all p-values<0.05); whereas, the underweight group had significantly lower values for VC and ratio of expected to measured VC (p-values<0.01). Furthermore, underweight subjects differed significantly as compared to normal weight subjects with lower MPT (p=0.025) and higher lowest-F0 (p=0.035). Finally the obese group showed significantly lower shimmer values than the normal weight subjects (p<0.05). Body weight and body fat volume appear to influence select objective measures of voice quality, vocal aerodynamics, and phonatory range performance.

  20. Visual System Involvement in Patients with Newly Diagnosed Parkinson Disease.

    PubMed

    Arrigo, Alessandro; Calamuneri, Alessandro; Milardi, Demetrio; Mormina, Enricomaria; Rania, Laura; Postorino, Elisa; Marino, Silvia; Di Lorenzo, Giuseppe; Anastasi, Giuseppe Pio; Ghilardi, Maria Felice; Aragona, Pasquale; Quartarone, Angelo; Gaeta, Michele

    2017-12-01

    Purpose To assess intracranial visual system changes of newly diagnosed Parkinson disease in drug-naïve patients. Materials and Methods Twenty patients with newly diagnosed Parkinson disease and 20 age-matched control subjects were recruited. Magnetic resonance (MR) imaging (T1-weighted and diffusion-weighted imaging) was performed with a 3-T MR imager. White matter changes were assessed by exploring a white matter diffusion profile by means of diffusion-tensor imaging-based parameters and constrained spherical deconvolution-based connectivity analysis and by means of white matter voxel-based morphometry (VBM). Alterations in occipital gray matter were investigated by means of gray matter VBM. Morphologic analysis of the optic chiasm was based on manual measurement of regions of interest. Statistical testing included analysis of variance, t tests, and permutation tests. Results In the patients with Parkinson disease, significant alterations were found in optic radiation connectivity distribution, with decreased lateral geniculate nucleus V2 density (F, -8.28; P < .05), a significant increase in optic radiation mean diffusivity (F, 7.5; P = .014), and a significant reduction in white matter concentration. VBM analysis also showed a significant reduction in visual cortical volumes (P < .05). Moreover, the chiasmatic area and volume were significantly reduced (P < .05). Conclusion The findings show that visual system alterations can be detected in early stages of Parkinson disease and that the entire intracranial visual system can be involved. © RSNA, 2017 Online supplemental material is available for this article.

  1. Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images.

    PubMed

    Seuss, Hannes; Janka, Rolf; Prümmer, Marcus; Cavallaro, Alexander; Hammon, Rebecca; Theis, Ragnar; Sandmair, Martin; Amann, Kerstin; Bäuerle, Tobias; Uder, Michael; Hammon, Matthias

    2017-04-01

    Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.

  2. Real-time Interpolation for True 3-Dimensional Ultrasound Image Volumes

    PubMed Central

    Ji, Songbai; Roberts, David W.; Hartov, Alex; Paulsen, Keith D.

    2013-01-01

    We compared trilinear interpolation to voxel nearest neighbor and distance-weighted algorithms for fast and accurate processing of true 3-dimensional ultrasound (3DUS) image volumes. In this study, the computational efficiency and interpolation accuracy of the 3 methods were compared on the basis of a simulated 3DUS image volume, 34 clinical 3DUS image volumes from 5 patients, and 2 experimental phantom image volumes. We show that trilinear interpolation improves interpolation accuracy over both the voxel nearest neighbor and distance-weighted algorithms yet achieves real-time computational performance that is comparable to the voxel nearest neighbor algrorithm (1–2 orders of magnitude faster than the distance-weighted algorithm) as well as the fastest pixel-based algorithms for processing tracked 2-dimensional ultrasound images (0.035 seconds per 2-dimesional cross-sectional image [76,800 pixels interpolated, or 0.46 ms/1000 pixels] and 1.05 seconds per full volume with a 1-mm3 voxel size [4.6 million voxels interpolated, or 0.23 ms/1000 voxels]). On the basis of these results, trilinear interpolation is recommended as a fast and accurate interpolation method for rectilinear sampling of 3DUS image acquisitions, which is required to facilitate subsequent processing and display during operating room procedures such as image-guided neurosurgery. PMID:21266563

  3. Real-time interpolation for true 3-dimensional ultrasound image volumes.

    PubMed

    Ji, Songbai; Roberts, David W; Hartov, Alex; Paulsen, Keith D

    2011-02-01

    We compared trilinear interpolation to voxel nearest neighbor and distance-weighted algorithms for fast and accurate processing of true 3-dimensional ultrasound (3DUS) image volumes. In this study, the computational efficiency and interpolation accuracy of the 3 methods were compared on the basis of a simulated 3DUS image volume, 34 clinical 3DUS image volumes from 5 patients, and 2 experimental phantom image volumes. We show that trilinear interpolation improves interpolation accuracy over both the voxel nearest neighbor and distance-weighted algorithms yet achieves real-time computational performance that is comparable to the voxel nearest neighbor algrorithm (1-2 orders of magnitude faster than the distance-weighted algorithm) as well as the fastest pixel-based algorithms for processing tracked 2-dimensional ultrasound images (0.035 seconds per 2-dimesional cross-sectional image [76,800 pixels interpolated, or 0.46 ms/1000 pixels] and 1.05 seconds per full volume with a 1-mm(3) voxel size [4.6 million voxels interpolated, or 0.23 ms/1000 voxels]). On the basis of these results, trilinear interpolation is recommended as a fast and accurate interpolation method for rectilinear sampling of 3DUS image acquisitions, which is required to facilitate subsequent processing and display during operating room procedures such as image-guided neurosurgery.

  4. Robust tissue-air volume segmentation of MR images based on the statistics of phase and magnitude: Its applications in the display of susceptibility-weighted imaging of the brain.

    PubMed

    Du, Yiping P; Jin, Zhaoyang

    2009-10-01

    To develop a robust algorithm for tissue-air segmentation in magnetic resonance imaging (MRI) using the statistics of phase and magnitude of the images. A multivariate measure based on the statistics of phase and magnitude was constructed for tissue-air volume segmentation. The standard deviation of first-order phase difference and the standard deviation of magnitude were calculated in a 3 x 3 x 3 kernel in the image domain. To improve differentiation accuracy, the uniformity of phase distribution in the kernel was also calculated and linear background phase introduced by field inhomogeneity was corrected. The effectiveness of the proposed volume segmentation technique was compared to a conventional approach that uses the magnitude data alone. The proposed algorithm was shown to be more effective and robust in volume segmentation in both synthetic phantom and susceptibility-weighted images of human brain. Using our proposed volume segmentation method, veins in the peripheral regions of the brain were well depicted in the minimum-intensity projection of the susceptibility-weighted images. Using the additional statistics of phase, tissue-air volume segmentation can be substantially improved compared to that using the statistics of magnitude data alone. (c) 2009 Wiley-Liss, Inc.

  5. Effect of curcumin on Bcl-2 and Bax expression in nude mice prostate cancer.

    PubMed

    Yang, Jiayi; Ning, Jianping; Peng, Linlin; He, Dan

    2015-01-01

    Prostate cancer is a common malignant tumor in urinary system. Curcumin has curative effect on many kinds of cancers and can inhibit prostate cancer (PC)-3 cells proliferation. This study aimed to explore the curcumin induced prostate cancer cell apoptosis and apoptosis related proteins Bcl-2 and Bax expression. PC-3 cells were injected subcutaneously to the nude mice to establish the tumor model. The nude mice were randomly divided into group C (normal saline), group B (6% polyethylene glycol and 6% anhydrous ethanol), group H, M, L (100 mg/kg, 50 mg/kg, and 25 mg/kg curcumin). The tumor volume was measured every 6 days to draw the tumor growth curve. The mice were killed at the 30(th) day after injection to weight the tumor. TUNEL assay was applied to determine cell apoptosis. Immunohistochemistry was used to detect Bcl-2 and Bax expression. The tumor volume and weight in group H, M, L were significantly lower than the control group (C, B) (P<0.05), and the inhibitory rate increased following the curcumin dose increase. Compared with the control group, Bcl-2 expression in group H, M, L gradually decreased, while Bax protein expression increased (P<0.05). The cell apoptosis rate showed no statistical difference between group B and C, while it increased in curcumin group H, M, and L (P<0.05). Curcumin could inhibit PC-3 growth, decrease tumor volume, reduce tumor weight, and induce cell apoptosis under the skin of nude mice by up-regulating Bax and down-regulating Bcl-2.

  6. Weight and Volume Determination for Planted Loblolly Pine in North Louisiana

    Treesearch

    Ray A. Newbold; V. Clark Baldwin; Gary Hill

    2001-01-01

    The objective of this study was to assess the variability in weight-to-volume relationships in loblolly pine (Pinus taeda L.) plantations and to determine predictability based on stand age, site quality, and/or tree size. Trees ages ranged from 11 to 40 years, with diameters to 2 1 inches and heights to 9 1 feet. Measured site indices ranged from 45...

  7. Global Fleet Station: Station Ship Concept

    DTIC Science & Technology

    2008-02-01

    The basic ISO TEU containers can be designed for any number of configurations and provide many different capabilities. For example there are...Design Design Process The ship was designed using an iterative weight and volume balancing method . This method assigns a weight and volume to each...from existing merchant ships3. Different ship types are modeled in the algorithm though the selection of appropriate non-dimensional factors

  8. Weight, Volume, and Physical Properties of Major Hardwood Species in the Piedmont

    Treesearch

    Alexander Clark; Douglas R. Phillips; Douglas J. Frederick

    1986-01-01

    Weight, volume, and physical properties of trees 1 to 20 inches d.b.h.were determined for red maple, sweetgum, sycamore, yellow-poplar, elm, hickory, chestnut oak, scarlet oak, southern red oak, and white oak in the Piedmont of the Southeastern United States. A total of 772 trees were destructively sampled at 16 locations from Viryinia to Alabama. Hard hardwoods, soft...

  9. 46 CFR 160.176-3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... that, in lieu of the weight and displacement values prescribed in Tables 160.047-4(c)(2) and § 160.047... displacement of 9.0 ±0.25 lb., and the back insert must have a weight of kapok of at least 5.5 oz. and a volume displacement of 6.0 ±0.25 lb. To achieve the specified volume displacement, front insert envelopes may be...

  10. Effects of dietary interventions on liver volume in humans.

    PubMed

    Bian, Hua; Hakkarainen, Antti; Lundbom, Nina; Yki-Järvinen, Hannele

    2014-04-01

    To compare effects of similar weight loss induced either by a short-term low-carbohydrate or by a long-term hypocaloric diet, and to determine effects of high carbohydrate overfeeding on liver total, lean, and fat volumes. Liver total, lean, and fat volumes were measured before and after (i) a 6-day low-carbohydrate diet (n = 17), (ii) a 7-month standard hypocaloric diet (n = 26), and (iii) a 3-week high-carbohydrate diet (n = 17), by combining magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy ((1) H-MRS) techniques. At baseline, three groups were comparable with respect to age, body mass index, liver volumes and the liver fat content. Body weight decreased similarly by the short-term and long-term hypocaloric diets. Liver total volume decreased significantly more during the short-term low-carbohydrate (-22 ± 2%) than the long-term (-7 ± 2%) hypocaloric diet (P < 0.001). This was due to a greater decrease in liver lean volume in the short-term (-20 ± 2%) than the long-term (-4 ± 2%) weight loss group (P < 0.001). Decreases in liver fat were comparable. Liver volume increased by 9 ± 3% due to overfeeding (P< 0.02 for before vs. after). These data support the use of a short-term low-carbohydrate diet whenever a reduction in liver volume is desirable. Overeating carbohydrate is harmful because it increases liver volume. Copyright © 2013 The Obesity Society.

  11. Weighted south-wide average pulpwood prices

    Treesearch

    James E. Granskog; Kevin D. Growther

    1991-01-01

    Weighted average prices provide a more accurate representation of regional pulpwood price trends when production volumes valy widely by state. Unweighted South-wide average delivered prices for pulpwood, as reported by Timber Mart-South, were compared to average annual prices weighted by each state's pulpwood production from 1977 to 1986. Weighted average prices...

  12. 7 CFR 981.61 - Redetermination of kernel weight.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Redetermination of kernel weight. 981.61 Section 981... GROWN IN CALIFORNIA Order Regulating Handling Volume Regulation § 981.61 Redetermination of kernel weight. The Board, on the basis of reports by handlers, shall redetermine the kernel weight of almonds...

  13. 7 CFR 981.60 - Determination of kernel weight.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Determination of kernel weight. 981.60 Section 981.60... Regulating Handling Volume Regulation § 981.60 Determination of kernel weight. (a) Almonds for which settlement is made on kernel weight. All lots of almonds, whether shelled or unshelled, for which settlement...

  14. Design and comparative analysis of 10 MW class superconducting wind power generators according to different types of superconducting wires

    NASA Astrophysics Data System (ADS)

    Sung, Hae-Jin; Kim, Gyeong-Hun; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Kim, Jong-Yul

    2013-11-01

    Wind turbine concepts can be classified into the geared type and the gearless type. The gearless type wind turbine is more attractive due to advantages of simplified drive train and increased energy yield, and higher reliability because the gearbox is omitted. In addition, this type resolves the weight issue of the wind turbine with the light weight of gearbox. However, because of the low speed operation, this type has disadvantage such as the large diameter and heavy weight of generator. Super-Conducting (SC) wind power generator can reduce the weight and volume of a wind power system. Properties of superconducting wire are very different from each company. This paper considers the design and comparative analysis of 10 MW class SC wind power generators according to different types of SC wires. Super-Conducting Synchronous Generators (SCSGs) using YBCO and Bi-2223 wires are optimized by an optimal method. The magnetic characteristics of the SCSGs are investigated using the finite elements method program. The optimized specifications of the SCSGs are discussed in detail, and the optimization processes can be used effectively to develop large scale wind power generation systems.

  15. Generation of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies

    PubMed Central

    Ingham, Eileen; Fisher, John; Tipper, Joanne L

    2014-01-01

    It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volumes of nanometre-sized ultra-high-molecular-weight polyethylene wear particles suitable for cell culture studies. In this study, wear simulation methods were investigated to generate a large volume of endotoxin-free clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles. Both single-station and six-station multidirectional pin-on-plate wear simulators were used to generate ultra-high-molecular-weight polyethylene wear particles under sterile and non-sterile conditions. Microbial contamination and endotoxin levels in the lubricants were determined. The results indicated that microbial contamination was absent and endotoxin levels were low and within acceptable limits for the pharmaceutical industry, when a six-station pin-on-plate wear simulator was used to generate ultra-high-molecular-weight polyethylene wear particles in a non-sterile environment. Different pore-sized polycarbonate filters were investigated to isolate nanometre-sized ultra-high-molecular-weight polyethylene wear particles from the wear test lubricants. The use of the filter sequence of 10, 1, 0.1, 0.1 and 0.015 µm pore sizes allowed successful isolation of ultra-high-molecular-weight polyethylene wear particles with a size range of < 100 nm, which was suitable for cell culture studies. PMID:24658586

  16. Generation of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies.

    PubMed

    Liu, Aiqin; Ingham, Eileen; Fisher, John; Tipper, Joanne L

    2014-04-01

    It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volumes of nanometre-sized ultra-high-molecular-weight polyethylene wear particles suitable for cell culture studies. In this study, wear simulation methods were investigated to generate a large volume of endotoxin-free clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles. Both single-station and six-station multidirectional pin-on-plate wear simulators were used to generate ultra-high-molecular-weight polyethylene wear particles under sterile and non-sterile conditions. Microbial contamination and endotoxin levels in the lubricants were determined. The results indicated that microbial contamination was absent and endotoxin levels were low and within acceptable limits for the pharmaceutical industry, when a six-station pin-on-plate wear simulator was used to generate ultra-high-molecular-weight polyethylene wear particles in a non-sterile environment. Different pore-sized polycarbonate filters were investigated to isolate nanometre-sized ultra-high-molecular-weight polyethylene wear particles from the wear test lubricants. The use of the filter sequence of 10, 1, 0.1, 0.1 and 0.015 µm pore sizes allowed successful isolation of ultra-high-molecular-weight polyethylene wear particles with a size range of < 100 nm, which was suitable for cell culture studies.

  17. Left ventricular mass in elite olympic weight lifters.

    PubMed

    Lalande, Sophie; Baldi, James Christopher

    2007-10-01

    The existence of resistance training-induced left ventricular (LV) concentric hypertrophy is equivocal. Although some have described significant LV hypertrophy, others have suggested that training-induced LV hypertrophy is proportional to increased fat free mass (FFM) and thus a normal physiologic response to training. Method limitations, steroid use, and type of training may contribute to discrepant findings. Thus, LV structure and volumes are determined using magnetic resonance imaging. Body composition was determined using dual-energy x-ray absorptiometry in 9 elite Olympic weight lifters and 10 age- and weight-matched recreationally active controls. LV structure and volumes were determined by acquiring 6 short- and 3 long-axis magnetic resonance imaging scans of the left ventricle, whereas LV wall thickness was defined as the average of 6 midventricular segment thickness measurements. Weight lifters had the same age, weight, and FFM, but were shorter and had a greater body mass index than controls. LV mass was not different in weight lifters and controls, but was lower in weight lifters when indexed to FFM (2.56 +/- 0.07 vs 2.30 +/- 0.05, p = 0.01). LV mass correlated with FFM (r = 0.49, p = 0.04). However, LV mass was lower in weight lifters for a given FFM. LV wall thickness, as well as end-diastolic, end-systolic, and stroke volumes, were not different between groups. In conclusion, these results refute the hypothesis that resistance training induces LV concentric hypertrophy and suggest that Olympic weight lifting is associated with increases in FFM without a concomitant increase in LV mass.

  18. Gastric sensorimotor functions and hormone profile in normal weight, overweight, and obese people.

    PubMed

    Vazquez Roque, Maria I; Camilleri, Michael; Stephens, Debra A; Jensen, Michael D; Burton, Duane D; Baxter, Kari L; Zinsmeister, Alan R

    2006-12-01

    Peptide YY (PYY) levels are reported to be decreased in obesity. The relation between gastric functions, satiation, and gut hormones in obesity is incompletely understood. The aim of this study was to compare gastric volumes, emptying, maximum tolerated volumes, postchallenge symptoms, and selected gut hormones in normal, overweight, or obese healthy volunteers. In 73 nonbulimic normal, overweight, or obese participants weighing less than 137 kg, we measured gastric emptying of solids and liquids by scintigraphy (gastric emptying half-time [GE t(1/2)]); gastric volumes by single-photon emission computed tomography; maximum tolerated volumes and symptoms by satiation test; and plasma leptin, ghrelin, insulin, glucagon-like peptide 1, and PYY levels. Groups were compared using 1-way analysis of covariance adjusted for sex. Univariate associations among measured responses were assessed using Spearman correlations. Multiple linear regression models, adjusting for weight and sex, assessed the independent ability of gastric functions and hormones to predict satiation volume. Obese and overweight subjects had significantly lower postprandial gastric volumes, higher fasting and postprandial insulin and leptin levels, and lower fasting ghrelin and lower postprandial reduction in ghrelin levels. PYY levels were not different in obese or overweight subjects compared with controls. The GE t(1/2) was correlated inversely with postprandial PYY; increased body weight was associated with faster GE t(1/2) of solids (r(s) = 0.33, P = .005) and liquids (r(s) = 0.24, P = .04). Postprandial changes in gastric volume and PYY were independent predictors of satiation (both P = .01). Overweight or obesity are associated with lower postprandial gastric volumes and normal PYY levels. Gastric emptying influences postprandial PYY levels. Postprandial PYY and gastric volume independently predict satiation volume in nonbulimic people across a wide body mass index range.

  19. Volume-weighted particle-tracking method for solute-transport modeling; Implementation in MODFLOW–GWT

    USGS Publications Warehouse

    Winston, Richard B.; Konikow, Leonard F.; Hornberger, George Z.

    2018-02-16

    In the traditional method of characteristics for groundwater solute-transport models, advective transport is represented by moving particles that track concentration. This approach can lead to global mass-balance problems because in models of aquifers having complex boundary conditions and heterogeneous properties, particles can originate in cells having different pore volumes and (or) be introduced (or removed) at cells representing fluid sources (or sinks) of varying strengths. Use of volume-weighted particles means that each particle tracks solute mass. In source or sink cells, the changes in particle weights will match the volume of water added or removed through external fluxes. This enables the new method to conserve mass in source or sink cells as well as globally. This approach also leads to potential efficiencies by allowing the number of particles per cell to vary spatially—using more particles where concentration gradients are high and fewer where gradients are low. The approach also eliminates the need for the model user to have to distinguish between “weak” and “strong” fluid source (or sink) cells. The new model determines whether solute mass added by fluid sources in a cell should be represented by (1) new particles having weights representing appropriate fractions of the volume of water added by the source, or (2) distributing the solute mass added over all particles already in the source cell. The first option is more appropriate for the condition of a strong source; the latter option is more appropriate for a weak source. At sinks, decisions whether or not to remove a particle are replaced by a reduction in particle weight in proportion to the volume of water removed. A number of test cases demonstrate that the new method works well and conserves mass. The method is incorporated into a new version of the U.S. Geological Survey’s MODFLOW–GWT solute-transport model.

  20. Validation of graft and standard liver size predictions in right liver living donor liver transplantation.

    PubMed

    Chan, See Ching; Lo, Chung Mau; Chok, Kenneth S H; Sharr, William W; Cheung, Tan To; Tsang, Simon H Y; Chan, Albert C Y; Fan, Sheung Tat

    2011-12-01

    To assess the accuracy of a formula derived from 159 living liver donors to estimate the liver size of a normal subject: standard liver weight (g) = 218 + body weight (kg) × 12.3 + 51 (if male). Standard liver volume (SLV) is attained by a conversion factor of 1.19 mL/g. The total liver volume (TLV) of each of the subsequent consecutive 126 living liver donors was determined using the right liver graft weight (RGW) on the back table, right/left liver volume ratio on computed tomography, and the conversion factor. The estimated right liver graft weight (ERGW) was determined by the right liver volume on computed tomography (CT) and the conversion factor. SLV and ERGW were compared with TLV and RGW, respectively, by paired sample t test. Donor characteristics of both series were similar. SLV and TLV were 1,099.6 ± 139.6 and 1,108.5 ± 175.2 mL, respectively, ( R 2  = 0.476) ( p  = 0.435). The difference between SLV and TLV was only -8.9 ± 128.2 mL (-1.0 ± 11.7%). ERGW and RGW were 601.5 ± 104.1 and 597.1 ± 102.2 g, respectively ( R 2  = 0.781) ( p  = 0.332). The conversion factor from liver weight to volume for this series was 1.20 mL/g. The difference between ERGW and RGW was 4.3 ± 49.8 g (0.3 ± 8.8%). ERGW was smaller than RGW for over 10% (range 0.21-40.66 g) in 18 of the 126 donors. None had the underestimation of RGW by over 20%. SLV and graft weight estimations were accurate using the formula and conversion factor.

  1. Impact of Diet and/or Exercise Intervention on Infrapatellar Fat Pad Morphology: Secondary Analysis from the Intensive Diet and Exercise for Arthritis (IDEA) Trial.

    PubMed

    Pogacnik Murillo, Aarón Leonardo; Eckstein, Felix; Wirth, Wolfgang; Beavers, Daniel; Loeser, Richard F; Nicklas, Barbara J; Mihalko, Shannon L; Miller, Gary D; Hunter, David J; Messier, Stephen P

    2017-01-01

    The infrapatellar fat pad (IPFP) represents intra-articular adipose tissue that may contribute to intra-articular inflammation and pain by secretion of proinflammatory cytokines. Here we examined the impact of weight loss by diet and/or exercise interventions on the IPFP volume. Intensive Diet and Exercise for Arthritis (IDEA) was a single-blinded, single-center, 18-month, prospective, randomized controlled trial that enrolled 454 overweight and obese older adults with knee pain and radiographic osteoarthritis. Participants were randomized to 1 of 3 groups: exercise-only control (E), diet-induced weight loss (D), and diet-induced weight loss + exercise (D+E). In a subsample (n = 106; E: n = 36, D: n = 35, and D+E: n = 35), magnetic resonance images were acquired at baseline and at the 18-month follow-up, from which we analyzed IPFP volume, surface areas, and thickness in this secondary analysis. The average weight loss amounted to 1.0% in the E group, 10.5% in the D group, and 13.0% in the D+E group. A significant (p < 0.01) reduction in IPFP volume was observed in the E (2.1%), D (4.0%), and D+E (5.2%) groups. The IPFP volume loss in the D+E group was significantly greater than that in the E group (p < 0.05) when not adjusting for parallel comparisons. Across intervention groups, there were significant correlations between IPFP volume change, individual weight loss (r = 0.40), and change in total body fat mass (dual-energy X-ray absorptiometry; r = 0.44, n = 88) and in subcutaneous thigh fat area (computed tomography; r = 0.32, n = 82). As a potential link between obesity and knee osteoarthritis, the IPFP was sensitive to intervention by diet and/or exercise, and its reduction was correlated with changes in weight and body fat. © 2017 S. Karger AG, Basel.

  2. IMPACT OF DIET AND/OR EXERCISE INTERVENTION ON INFRAPATELLAR FAT PAD MORPHOLOGY - SECONDARY ANALYSIS FROM THE INTENSIVE DIET AND EXERCISE FOR ARTHRITIS (IDEA) TRIAL

    PubMed Central

    Murillo, A. Pogacnik; Eckstein, F.; Wirth, W.; Beavers, D.; Loeser, R. F.; Nicklas, B. J.; Mihalko, S.L.; Miller, G.D.; Hunter, D.J.; Messier, S. P.

    2017-01-01

    Objectives The infrapatellar fat pad (IPFP) represents intra-articular adipose tissue that may contribute to intra-articular inflammation and pain by secretion of pro-inflammatory cytokines. Here we examined the impact of weight loss by diet and/or exercise interventions on IPFP volume. Methods Intensive Diet and Exercise for Arthritis (IDEA) was a single-blinded, single-center, 18-month, prospective, randomized controlled trial that enrolled 454 overweight and obese older adults with knee pain and radiographic osteoarthritis. Participants were randomized to 1 of 3 groups: exercise only control (E), diet-induced weight loss (D), and diet-induced weight loss + exercise (D+E). In a subsample (n=106; E: n=36; D: n=35; D+E: n=35), magnetic resonance images were acquired at baseline and 18-month follow-up, from which we analyzed IPFP volume, surface areas and thickness in this secondary analysis. Results Average weight loss in each group amounted to 1.0% in E, 10.5% in D, and 13.0% in D+E. A significant (p< 0.01) reduction in IPFP volume was observed in E (2.1%), D (4.0%) and D+E (5.2%). The IPFP volume loss in D+E was significantly greater than that in E (p<0.05) when not adjusting for parallel comparisons. Across intervention groups, there were significant correlations between IPFP volume change, individual weight loss (r=0.40), and change in total body fat mass (DXA; r=0.44; n=88) and in subcutaneous thigh fat area (CT; r=0.32; n=82). Conclusions As a potential link between obesity and knee OA, the IPFP was sensitive to intervention by diet and/or exercise, and its reduction was correlated with change in weight and body fat. PMID:28222422

  3. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  4. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  5. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  6. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  7. 33 CFR 183.105 - Quantity of flotation required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of the dead weight; and (3) A weight in pounds that, when submerged, equals 62.4 times the volume in... of this section, “dead weight” means the maximum weight capacity marked on the boat minus the persons...

  8. Post-stroke dementia: the contribution of thalamus and basal ganglia changes.

    PubMed

    Lopes, Marcos Antonio; Firbank, Michael J; Widdrington, Michelle; Blamire, Andrew M; Kalaria, Raj N; O'Brien, John T

    2012-04-01

    The neurobiological basis of increased risk of dementia in stroke patients is unclear, though there are several related pathological changes, including white matter hyperintensities (WMH), and medial temporal atrophy. Subcortical gray matter structures have also been implicated in dementia resulting from vascular pathology, particularly vascular dementia. This study aimed to investigate the contribution of changes in subcortical gray matter structures to post-stroke dementia (PSD). T1- and T2-weighted images and T2-weighted fluid-attenuated inversion recovery (FLAIR) images were obtained on a 3-Tesla magnetic resonance (MR) system, in four groups aged over 75 years: post-stroke with dementia (PSD; 8), post-stroke no dementia (PSnoD; 33), Alzheimer's disease (AD; 26) and controls (30). Automated software was used to measure the volume of thalamus, putamen, caudate nucleus, and hippocampus as well as total WMH volume. The number of subcortical lacunes was also counted. The number of caudate lacunes was higher in the PSnoD group, compared with AD (p = 0.029) and controls (p = 0.019). The putamen volume was smaller in the stroke and AD groups, when compared with controls. In the whole stroke group, putamen lacunes were correlated with impairment in memory (Rey test; ρ = -0.365; p = 0.031), while WMH and hippocampal volume both correlated with global dysfunction. Our findings implicate a variety of neurobiological substrates of dementia, such as small vessel disease and Alzheimer pathology, which develop after stroke in an old older population, with a contribution from subcortical brain structures.

  9. Automatized spleen segmentation in non-contrast-enhanced MR volume data using subject-specific shape priors

    NASA Astrophysics Data System (ADS)

    Gloger, Oliver; Tönnies, Klaus; Bülow, Robin; Völzke, Henry

    2017-07-01

    To develop the first fully automated 3D spleen segmentation framework derived from T1-weighted magnetic resonance (MR) imaging data and to verify its performance for spleen delineation and volumetry. This approach considers the issue of low contrast between spleen and adjacent tissue in non-contrast-enhanced MR images. Native T1-weighted MR volume data was performed on a 1.5 T MR system in an epidemiological study. We analyzed random subsamples of MR examinations without pathologies to develop and verify the spleen segmentation framework. The framework is modularized to include different kinds of prior knowledge into the segmentation pipeline. Classification by support vector machines differentiates between five different shape types in computed foreground probability maps and recognizes characteristic spleen regions in axial slices of MR volume data. A spleen-shape space generated by training produces subject-specific prior shape knowledge that is then incorporated into a final 3D level set segmentation method. Individually adapted shape-driven forces as well as image-driven forces resulting from refined foreground probability maps steer the level set successfully to the segment the spleen. The framework achieves promising segmentation results with mean Dice coefficients of nearly 0.91 and low volumetric mean errors of 6.3%. The presented spleen segmentation approach can delineate spleen tissue in native MR volume data. Several kinds of prior shape knowledge including subject-specific 3D prior shape knowledge can be used to guide segmentation processes achieving promising results.

  10. Design integration and noise studies for jet STOL aircraft. Task 7A: Augmentor wing cruise blowing valveless system. Volume 1: System design and test integration

    NASA Technical Reports Server (NTRS)

    Roepcke, F. A.; Nickson, T. B.

    1973-01-01

    Exploratory design studies conducted to establish the configuration of an augmentor wing vruise blowing (valveless) system in a 150-passenger STOL airplane were reported in NASA CR-114570. Those studies have been updated to incorporate the results of static rig, flow duct, and wind tunnel tests. Minor adjustments in duct flow velocity, flap length, and blowing nozzle geometry were incorporated to provide airplane characteristics that minimize takeoff gross weight and achieve sideline noise objectives for an advanced commercial STOL airplane.

  11. Flexible radiator system

    NASA Technical Reports Server (NTRS)

    Oren, J. A.

    1982-01-01

    The soft tube radiator subsystem is described including applicable system requirements, the design and limitations of the subsystem components, and the panel manufacturing method. The soft tube radiator subsystem is applicable to payloads requiring 1 to 12 kW of heat rejection for orbital lifetimes per mission of 30 days or less. The flexible radiator stowage volume required is about 60% and the system weight is about 40% of an equivalent heat rejection rigid panel. The cost should also be considerably less. The flexible radiator is particularly suited to shuttle orbiter sortie payloads and also whose mission lengths do not exceed the 30 day design life.

  12. Effects of addition of different fibers on rheological characteristics of cake batter and quality of cakes.

    PubMed

    Aydogdu, Ayca; Sumnu, Gulum; Sahin, Serpil

    2018-02-01

    The aim of this study was to investigate the effects of addition of dietary fibers on rheological properties of batter and cake quality. Wheat flour was replaced by 5 and 10% (wt%) oat, pea, apple and lemon fibers. All cake batters showed shear thinning behavior. Incorporation of fibers increased consistency index (k), storage modulus (G') and loss modulus (G″). As quality parameters, specific volume, hardness, weight loss, color and microstructure of cakes were investigated. Cakes containing oat and pea fibers (5%) had similar specific volume and texture with control cakes which contained no fiber. As fiber concentration increased, specific volume decreased but hardness increased. No significant difference was found between weight loss of control cake and cakes with oat, pea and apple fibers. Lemon fiber enriched cakes had the lowest specific volume, weight loss and color difference. When microstructural images were examined, it was seen that control cake had more porous structure than fiber enriched cakes. In addition, lemon and apple fiber containing cakes had less porous crumb structure as compared to oat and pea containing ones. Oat and pea fiber (5%) enriched cakes had similar physical properties (volume, texture and color) with control cakes.

  13. No changes in weight and body fat in lactating adolescent and adult women from Mexico.

    PubMed

    Caire-Juvera, Graciela; Casanueva, Esther; Bolaños-Villar, Adriana Verónica; de Regil, Luz María; Calderón de la Barca, Ana María

    2012-01-01

    To evaluate changes in weight and body fat of Mexican adolescent compared to those of adult lactating women from the Northwest (NM) and Central (CM) regions of Mexico in the first trimester postpartum. A prospective design was used to evaluate 41 exclusively breastfeeding women (21 adolescents and 20 adults) recruited 1-2 days after delivering a healthy singleton at the Hospital Infantil del Estado de Sonora (Northwest Mexico) and Instituto Nacional de Perinatología, in Mexico City. Socioeconomic status, height, body weight and composition, dietary intake, physical activity, and milk volume (quantified by deuterium dilution method) were measured at the 1st and 3rd month postpartum. Women did not lose weight throughout the first trimester postpartum. Mean postpartum weight retention at the end of the study was 3.8 kg. No differences in weight and body mass index (BMI) were found between adolescent and adult women in both periods. Energy and macronutrient intakes, physical activity and milk volume were similar between the two groups of women. In both periods, adolescents from the CM region had lower weight, BMI, and body fat than adolescents from the NM region (P<0.05). At the 3rd month, pregestational weight (P < 0.0001) was a predictor of BMI, and region (P < 0.05) and milk volume (P < 0.01) were associated with percentage of body fat. Exclusively breastfeeding for 3 months did not reduce weight or body fat in the Mexican population of this study. Efforts to avoid weight retention in the lactation period may contribute to prevent overweight and obesity in women. Copyright © 2012 Wiley Periodicals, Inc.

  14. Chip Scale Ultra-Stable Clocks: Miniaturized Phonon Trap Timing Units for PNT of CubeSats

    NASA Technical Reports Server (NTRS)

    Rais-Zadeh, Mina; Altunc, Serhat; Hunter, Roger C.; Petro, Andrew

    2016-01-01

    The Chip Scale Ultra-Stable Clocks (CSUSC) project aims to provide a superior alternative to current solutions for low size, weight, and power timing devices. Currently available quartz-based clocks have problems adjusting to the high temperature and extreme acceleration found in space applications, especially when scaled down to match small spacecraft size, weight, and power requirements. The CSUSC project aims to utilize dual-mode resonators on an ovenized platform to achieve the exceptional temperature stability required for these systems. The dual-mode architecture utilizes a temperature sensitive and temperature stable mode simultaneously driven on the same device volume to eliminate ovenization error while maintaining extremely high performance. Using this technology it is possible to achieve parts-per-billion (ppb) levels of temperature stability with multiple orders of magnitude smaller size, weight, and power.

  15. Spinal focal lesion detection in multiple myeloma using multimodal image features

    NASA Astrophysics Data System (ADS)

    Fränzle, Andrea; Hillengass, Jens; Bendl, Rolf

    2015-03-01

    Multiple myeloma is a tumor disease in the bone marrow that affects the skeleton systemically, i.e. multiple lesions can occur in different sites in the skeleton. To quantify overall tumor mass for determining degree of disease and for analysis of therapy response, volumetry of all lesions is needed. Since the large amount of lesions in one patient impedes manual segmentation of all lesions, quantification of overall tumor volume is not possible until now. Therefore development of automatic lesion detection and segmentation methods is necessary. Since focal tumors in multiple myeloma show different characteristics in different modalities (changes in bone structure in CT images, hypointensity in T1 weighted MR images and hyperintensity in T2 weighted MR images), multimodal image analysis is necessary for the detection of focal tumors. In this paper a pattern recognition approach is presented that identifies focal lesions in lumbar vertebrae based on features from T1 and T2 weighted MR images. Image voxels within bone are classified using random forests based on plain intensities and intensity value derived features (maximum, minimum, mean, median) in a 5 x 5 neighborhood around a voxel from both T1 and T2 weighted MR images. A test data sample of lesions in 8 lumbar vertebrae from 4 multiple myeloma patients can be classified at an accuracy of 95% (using a leave-one-patient-out test). The approach provides a reasonable delineation of the example lesions. This is an important step towards automatic tumor volume quantification in multiple myeloma.

  16. Effects of repeated cycles of starvation and refeeding on lungs of growing rats.

    PubMed

    Sahebjami, H; Domino, M

    1992-12-01

    Adult male rats were subjected to four cycles of mild starvation (2 wk) and refeeding (1 wk) and were compared with a fed group. Starvation was induced by giving rats one-third of their measured daily food consumption. During each starvation cycle, rats lost approximately 20% of their body weight. Despite catch-up growth and overall weight gain, starved rats had lower final body weight than fed rats. Lung dry weight and lung volumes were also reduced in the starved group. The mechanical properties of air- and saline-filled lungs did not change significantly with repeated cycles of starvation. Mean linear intercept was similar in the two groups, but alveolar surface area was reduced in the starved rats. Total content of crude connective tissue and concentration per lung dry weight of hydroxyproline and crude connective tissue were reduced in starved rats. We conclude that lung growth is retarded in growing rats subjected to repeated cycles of mild starvation and refeeding, as manifested by smaller lung volume and reduced alveolar surface area. Because alveolar size is unchanged, a reduced number of alveoli is most likely responsible for decreased lung volumes.

  17. 40 CFR 60.393 - Performance test and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... volume of applied solids emitted after the control device, by the following equation: N=G[1-FE] (A... month by the following equation: EC16NO91.031 (v) If the volume weighted average mass of VOC per volume...

  18. Weighting factors for computing the relation between tree volume and d.b.h. in the Pacific Northwest.

    Treesearch

    Donald R. Gedney; Floyd A. Johnson

    1959-01-01

    Timber cruising is frequently made easier through use of local volume tables based on d.b.h. alone. These tables are made by establishing the relation between volume and d.b.h. from measurements (including height) made on sample trees in the stand. The sample-tree measurements are converted to volumes through use of standard volume tables, and a volume-diameter curve...

  19. 15 CFR 10.6 - Procedures for acceptance of a recommended standard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., divided by three. No consideration will be given to volume of production or volume of distribution in... who use or consume the product covered by the standard. (8) “Acceptance by volume of production” means.... The weighting of each response will be made in accordance with the volume of production represented by...

  20. What volume of seeds can a chimpanzee carry in its body?

    PubMed

    Nakamura, Michio; Sakamaki, Tetsuya; Zamma, Koichiro

    2017-01-01

    Great apes are important seed dispersers with large bodies, able to swallow large seeds and travel long distances. Although there have been several studies investigating seed dispersal quality [sensu Schupp (Vegetatio 107/108:15-29, 1993)] by chimpanzees, there is little information on the volume of seeds they can carry in their bodies. When a relatively fresh corpse of a mature female chimpanzee was found at Mahale, Tanzania, we took advantage of the rare opportunity to investigate the total weight and cubic volume of seeds recovered from the corpse. The seeds contained in the corpse weighed 258.8 g (dry weight) and measured 489.4 cm 3 . The volume of seeds was 14.7 % of the previously reported capacity of the digestive tract of a chimpanzee in captivity. We also indirectly estimated the volume of seeds from the values of observed seed volume in feces, the reported number of defecations per day, and the seed passage time. The estimated volume was significantly lower than the observed seed volume, suggesting that the number of defecations per day is underestimated because it may not include nighttime defecation.

  1. Echocardiographic knowledge-based reconstruction for quantification of the systemic right ventricle in young adults with repaired D-transposition of great arteries.

    PubMed

    Kutty, Shelby; Li, Ling; Polak, Amanda; Gribben, Paul; Danford, David A

    2012-03-15

    The systemic right ventricle (RV) in congenital heart disease is susceptible to progressive dilation and dysfunction. A 2-dimensional echocardiographic means for serial monitoring of the RV would be of great value in this clinical setting. We used 2-dimensional echocardiography with knowledge-based reconstruction (2DE-KBR) for evaluation of systemic RV. Patients with d-transposition of great arteries repaired with an atrial switch and without implanted pacemakers were prospectively recruited for same-day 2DE-KBR and cardiac magnetic resonance (CMR) imaging. RV images were acquired in various 2-dimensional imaging planes using a 3-dimensional space-localizing device attached to the imaging transducer and 3-dimensional reconstruction was performed. RV end-diastolic volume, end-systolic volume, and ejection fraction (EF) were calculated and compared to volumetric CMR analysis. Fifteen patients (7 women, 8 men, 24 ± 7 years old, weight 67 ± 12 kg) were studied. There was good agreement of 2DE-KBR and CMR measurements. Mean RV end-diastolic volume was 221 ± 39 ml with 2DE-KBR and 231 ± 35 ml with CMR (r = 0.80); mean end-systolic volume was 129 ± 35 ml with KBR and 132 ± 30 ml with CMR (r = 0.82), and EF was 42 ± 10% with KBR and 43 ± 7% with CMR (r = 0.86). For 2DE-KBR mean interobserver variabilities were 4.6%, 2.6%, and 4.3%; intraobserver variabilities were 3.2%, 3.1%, and 2.3%, respectively, for end-diastolic volume, end-systolic volume, and EF. In conclusion, this study demonstrates the clinical feasibility of quantifying systemic RV volumes and function using 2DE-KBR in adolescents and young adults with repaired d-transposition of great arteries and good agreement of measurements with CMR. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Life and Utilization Criteria Identification in Design (LUCID). Volume 1

    DTIC Science & Technology

    1981-10-01

    stator, seal /spacer, etc. weights are added to these rotor weights in estimating module weights. Weights of other engine modules (combustor, augmentor...of turbine airfoil/platform cooling air and disk cooling/ seal leakage air), number of vanes and blades for the single stage high-pressure turbine, and...subroutines include hubs, shafts, seals and spacers in estimating rotor weights. Module weight is estimated by adding case and stator weights to the rotor

  3. Automatic Non-Destructive Growth Measurement of Leafy Vegetables Based on Kinect

    PubMed Central

    Hu, Yang; Wang, Le; Xiang, Lirong; Wu, Qian; Jiang, Huanyu

    2018-01-01

    Non-destructive plant growth measurement is essential for plant growth and health research. As a 3D sensor, Kinect v2 has huge potentials in agriculture applications, benefited from its low price and strong robustness. The paper proposes a Kinect-based automatic system for non-destructive growth measurement of leafy vegetables. The system used a turntable to acquire multi-view point clouds of the measured plant. Then a series of suitable algorithms were applied to obtain a fine 3D reconstruction for the plant, while measuring the key growth parameters including relative/absolute height, total/projected leaf area and volume. In experiment, 63 pots of lettuce in different growth stages were measured. The result shows that the Kinect-measured height and projected area have fine linear relationship with reference measurements. While the measured total area and volume both follow power law distributions with reference data. All these data have shown good fitting goodness (R2 = 0.9457–0.9914). In the study of biomass correlations, the Kinect-measured volume was found to have a good power law relationship (R2 = 0.9281) with fresh weight. In addition, the system practicality was validated by performance and robustness analysis. PMID:29518958

  4. Treating hypertension in hemodialysis improves symptoms seemingly unrelated to volume excess.

    PubMed

    Agarwal, Rajiv

    2016-01-01

    Among hemodialysis patients, probing dry weight is an effective strategy for improving control of hypertension. Whether controlling hypertension improves or worsens symptoms among such patients remains unclear. The purpose of the study was to develop a tool to evaluate symptoms and examine the relationship of the change in these symptoms with blood pressure (BP) control. Among patients participating in the Hemodialysis Patients Treated with Atenolol or Lisinopril (HDPAL) randomized controlled trial, a confirmatory factor analysis (CFA) was performed to establish the relationship between symptoms and organ systems. Next, the change in symptom scores pertaining to organ systems was analyzed using a mixed model. Finally, the independent effect of lowering home BP on change in symptoms was evaluated. Among 133 participants where symptoms were available at baseline, CFA revealed four level 1 domains: gastrointestinal symptoms, dialysis-related symptoms, cardiovascular symptoms and general symptoms. All except dialysis-related symptoms were ascribed to uremia (level 2 domain). Uremic symptoms improved over 6 months and then increased. Dialysis-related symptoms (fatigue, cramps and orthostatic dizziness) did not worsen despite lowering home BP. Probing dry weight was independently associated with an improvement in cardiovascular symptoms such as shortness of breath. Reducing BP through the use of a strategy that includes volume control and medication improves symptoms seemingly unrelated to volume excess. In long-term hemodialysis patients, treating hypertension using home BP measurements may improve well-being. Published by Oxford University Press on behalf of ERA-EDTA 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  5. Design of portable ultraminiature flow cytometers for medical diagnostics

    NASA Astrophysics Data System (ADS)

    Leary, James F.

    2018-02-01

    Design of portable microfluidic flow/image cytometry devices for measurements in the field (e.g. initial medical diagnostics) requires careful design in terms of power requirements and weight to allow for realistic portability. True portability with high-throughput microfluidic systems also requires sampling systems without the need for sheath hydrodynamic focusing both to avoid the need for sheath fluid and to enable higher volumes of actual sample, rather than sheath/sample combinations. Weight/power requirements dictate use of super-bright LEDs with top-hat excitation beam architectures and very small silicon photodiodes or nanophotonic sensors that can both be powered by small batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. Microfluidic cytometry also requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically in less than 15 minutes) initial medical decisions for patients in the field. This is not something conventional cytometry traditionally worries about, but is very important for development of small, portable microfluidic devices with small-volume throughputs. It also provides a more reasonable alternative to conventional tubes of blood when sampling geriatric and newborn patients for whom a conventional peripheral blood draw can be problematical. Instead one or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the doctor's office or field.

  6. The 1985 Army Experience Survey: Tabular Descriptions of Mid-Career Separatees. Volume 1

    DTIC Science & Technology

    1986-01-01

    processed through survey receipt control and sample management systems . Data were also keyed, edited, jcoded, and weighted. The coding schemes...270-271 048 R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY---------------------------------------272 273 049 E137...PROB. CHISQUARE APPROX. 41.551 10 0.0000 A -. 0 272 R136 -- REGION OF RESIDENCE WHEN YOU JOINED ARMY RECODED - WHAT STATE WERE YOU LIVING IN WHEN YOU

  7. Changes in subcutaneous fat cell volume and insulin sensitivity after weight loss.

    PubMed

    Andersson, Daniel P; Eriksson Hogling, Daniel; Thorell, Anders; Toft, Eva; Qvisth, Veronica; Näslund, Erik; Thörne, Anders; Wirén, Mikael; Löfgren, Patrik; Hoffstedt, Johan; Dahlman, Ingrid; Mejhert, Niklas; Rydén, Mikael; Arner, Erik; Arner, Peter

    2014-07-01

    Large subcutaneous fat cells associate with insulin resistance and high risk of developing type 2 diabetes. We investigated if changes in fat cell volume and fat mass correlate with improvements in the metabolic risk profile after bariatric surgery in obese patients. Fat cell volume and number were measured in abdominal subcutaneous adipose tissue in 62 obese women before and 2 years after Roux-en-Y gastric bypass (RYGB). Regional body fat mass by dual-energy X-ray absorptiometry; insulin sensitivity by hyperinsulinemic-euglycemic clamp; and plasma glucose, insulin, and lipid profile were assessed. RYGB decreased body weight by 33%, which was accompanied by decreased adipocyte volume but not number. Fat mass in the measured regions decreased and all metabolic parameters were improved after RYGB (P < 0.0001). Whereas reduced subcutaneous fat cell size correlated strongly with improved insulin sensitivity (P = 0.0057), regional changes in fat mass did not, except for a weak correlation between changes in visceral fat mass and insulin sensitivity and triglycerides. The curve-linear relationship between fat cell size and fat mass was altered after weight loss (P = 0.03). After bariatric surgery in obese women, a reduction in subcutaneous fat cell volume associates more strongly with improvement of insulin sensitivity than fat mass reduction per se. An altered relationship between adipocyte size and fat mass may be important for improving insulin sensitivity after weight loss. Fat cell size reduction could constitute a target to improve insulin sensitivity. © 2014 by the American Diabetes Association.

  8. Water electrolysis system - H2 and O2 generation. [for spacecraft atmosphere revitalization

    NASA Technical Reports Server (NTRS)

    Schubert, F. H.; Lee, M. K.; Davenport, R. J.; Quattrone, P. D.

    1978-01-01

    An oxygen generation system design based on the static feed water electrolysis concept is described. The system is designed to generate 4.20 kg/d of oxygen to satisfy the metabolic needs of a three-person crew, to compensate for spacecraft leakage, and to provide the oxygen required by the electrochemical depolarized CO2 concentrator. The system has a fixed hardware weight of 75 kg, occupies a volume of 0.11 cu m, and requires only 1.1 kw of electrical power. The static feed electrolysis concept is discussed, and experimental data on the high-performance electrode are presented.

  9. Implementation strategies for load center automation on the space station module/power management and distribution testbed

    NASA Technical Reports Server (NTRS)

    Watson, Karen

    1990-01-01

    The Space Station Module/Power Management and Distribution (SSM/PMAD) testbed was developed to study the tertiary power management on modules in large spacecraft. The main goal was to study automation techniques, not necessarily develop flight ready systems. Because of the confidence gained in many of automation strategies investigated, it is appropriate to study, in more detail, implementation strategies in order to find better trade-offs for nearer to flight ready systems. These trade-offs particularly concern the weight, volume, power consumption, and performance of the automation system. These systems, in their present implementation are described.

  10. Research of the small satellite data management system

    NASA Astrophysics Data System (ADS)

    Yu, Xiaozhou; Zhou, Fengqi; Zhou, Jun

    2007-11-01

    Small satellite is the integration of light weight, small volume and low launch cost. It is a promising approach to realize the future space mission. A detailed study of the data management system has been carried out, with using new reconfiguration method based on System On Programmable Chip (SOPC). Compared with common structure of satellite, the Central Terminal Unit (CTU), the Remote Terminal Unit (RTU) and Serial Data Bus (SDB) of the data management are all integrated in single chip. Thus the reliability of the satellite is greatly improved. At the same time, the data management system has powerful performance owing to the modern FPGA processing ability.

  11. Software For Nearly Optimal Packing Of Cargo

    NASA Technical Reports Server (NTRS)

    Fennel, Theron R.; Daughtrey, Rodney S.; Schwaab, Doug G.

    1994-01-01

    PACKMAN computer program used to find nearly optimal arrangements of cargo items in storage containers, subject to such multiple packing objectives as utilization of volumes of containers, utilization of containers up to limits on weights, and other considerations. Automatic packing algorithm employed attempts to find best positioning of cargo items in container, such that volume and weight capacity of container both utilized to maximum extent possible. Written in Common LISP.

  12. Solar concentrator technology development for space based applications, volume 2

    NASA Technical Reports Server (NTRS)

    Pintz, A.; Castle, C. H.; Reimer, R. R.

    1992-01-01

    Thermoelectric conversion using a radio-isotope heat source has been used where outer planetary space craft are too far away for absorbing significant solar energy. Solar dynamic power (SDP) conversion is one technology that offers advantages for applications within the inner planet region. Since SDP conversion efficiency can be 2 to 3 times higher than photovoltaic, the collecting surfaces are much reduced in area and therefore lighter. This becomes an advantage in allocating more weight to launched payloads. A second advantage results for low earth orbit applications. The reduced area results in lower drag forces on the spacecraft and requires less reboost propellant to maintain orbit. A third advantage occurs because of the sun-to-shade cycling while in earth orbit. Photovoltaic systems require batteries to store energy for use when in the shade, and battery life for periods of 10 to 15 years is not presently achievable. For these reasons the Solar Dynamics and Thermal Systems Branch at NASA LeRC has funded work in developing SDP systems. The generic SDP system uses a large parabolic solar concentrator to focus solar energy onto a power conversion device. The concentrators are large areas and must therefore be efficient and have low specific weights. Yet these surfaces must be precise and capable of being stowed in a launch vehicle and then deployed and sometimes unfurled in space. There are significant technical challenges in engineering such structures, and considerable investigation has been made to date. This is the second of two volumes reporting on the research done by the Advanced Manufacturing Center at Cleveland State University to assist NASA LeRC in evaluating this technology. This volume includes the appendices of selected data sets, drawings, and procedures. The objective of the grant was to restore the solar concentrator development technology of the 1960s while improving it with advances that have occurred since then. This report summarizes the work done from January 1989 through December 1991.

  13. Regenerative Performance of the NASA Symmetrical Solid Oxide Fuel Cell Design

    NASA Technical Reports Server (NTRS)

    Cable, Thomas L.; Setlock, John A.; Farmer, Serene C.; Eckel, Andy J.

    2009-01-01

    The NASA Glenn Research Center is developing both a novel cell design (BSC) and a novel ceramic fabrication technique to produce fuel cells predicted to exceed a specific power density of 1.0 kW/kg. The NASA Glenn cell design has taken a completely different approach among planar designs by removing the metal interconnect and returning to the use of a thin, doped LaCrO3 interconnect. The cell is structurally symmetrical. Both electrodes support the thin electrolyte and contain micro-channels for gas flow-- a geometry referred to as a bi-electrode supported cell or BSC. The cell characteristics have been demonstrated under both SOFC and SOE conditions. Electrolysis tests verify that this cell design operates at very high electrochemical voltage efficiencies (EVE) and high H2O conversion percentages, even at the low flow rates predicted for closed loop systems encountered in unmanned aerial vehicle (UAV) applications. For UAVs the volume, weight and the efficiency are critical as they determine the size of the water tank, the solar panel size, and other system requirements. For UAVs, regenerative solid oxide fuel cell stacks (RSOFC) use solar panels during daylight to generate power for electrolysis and then operate in fuel cell mode during the night to power the UAV and electronics. Recent studies, performed by NASA for a more electric commercial aircraft, evaluated SOFCs for auxiliary power units (APUs). System studies were also conducted for regenerative RSOFC systems. One common requirement for aerospace SOFCs and RSOFCs, determined independently in each application study, was the need for high specific power density and volume density, on the order of 1.0 kW/kg and greater than 1.0 kW/L. Until recently the best reported performance for SOFCs was 0.2 kW/kg or less for stacks. NASA Glenn is working to prototype the light weight, low volume BSC design for such high specific power aerospace applications.

  14. A study of physical properties of ODPA-p-PDA polyimide films

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Eftekhari, Abe; St.clair, Terry L.

    1990-01-01

    Physical properties were investigated of ODPA-p-PDA polyimide films, including their lower molecular weight versions with phthalimide endcaps. Free volume, determined by low energy positron annihilation in the test films, was the major parameter of interest since all other physical properties are ostensibly related to it. It affects the dielectric constant as well as the saturation moisture pickup of the test films. An empirical relation was developed between the free volume and molecular weight of the test films, comparable to the Mark-Houwink relation between the polymer solution viscosity and the molecular weight. Development of such a relation constitutes a unique achievement since it enables researchers to estimate the molecular weight of an intractable polymer in solid state for the first time.

  15. Structural Sizing of a Horizontal Take-Off Launch Vehicle with an Air Collection and Enrichment System

    NASA Technical Reports Server (NTRS)

    McCurdy, David R.; Roche, Joseph M.

    2004-01-01

    In support of NASA's Next Generation Launch Technology (NGLT) program, the Andrews Gryphon booster was studied. The Andrews Gryphon concept is a horizontal lift-off, two-stage-to-orbit, reusable launch vehicle that uses an air collection and enrichment system (ACES). The purpose of the ACES is to collect atmospheric oxygen during a subsonic flight loiter phase and cool it to cryogenic temperature, ultimately resulting in a reduced initial take-off weight To study the performance and size of an air-collection based booster, an initial airplane like shape was established as a baseline and modeled in a vehicle sizing code. The code, SIZER, contains a general series of volume, surface area, and fuel fraction relationships that tie engine and ACES performance with propellant requirements and volumetric constraints in order to establish vehicle closure for the given mission. A key element of system level weight optimization is the use of the SIZER program that provides rapid convergence and a great deal of flexibility for different tank architectures and material suites in order to study their impact on gross lift-off weight. This paper discusses important elements of the sizing code architecture followed by highlights of the baseline booster study.

  16. Space nuclear power applied to electric propulsion

    NASA Technical Reports Server (NTRS)

    Vicente, F. A.; Karras, T.; Darooka, D.; Isenberg, L.

    1989-01-01

    Space reactor power systems with characteristics ideal for advanced spacecraft systems applications are discussed. These characteristics are: high power-to-weight ratio (15 to 33 W/kg); high volume density (high ballistic coefficient); no preferential orientation in orbit; long operational life; high reliability; and total launch and operational safety. These characteristics allow the use of electric propulsion to raise spacecraft from low earth parking orbits to operational orbits, greatly increasing the useful orbit payload for a given launch vehicle by eliminating the need for a separation injection stage. A proposed demonstration mission is described.

  17. Spaceborne Hybrid-FPGA System for Processing FTIR Data

    NASA Technical Reports Server (NTRS)

    Bekker, Dmitriy; Blavier, Jean-Francois L.; Pingree, Paula J.; Lukowiak, Marcin; Shaaban, Muhammad

    2008-01-01

    Progress has been made in a continuing effort to develop a spaceborne computer system for processing readout data from a Fourier-transform infrared (FTIR) spectrometer to reduce the volume of data transmitted to Earth. The approach followed in this effort, oriented toward reducing design time and reducing the size and weight of the spectrometer electronics, has been to exploit the versatility of recently developed hybrid field-programmable gate arrays (FPGAs) to run diverse software on embedded processors while also taking advantage of the reconfigurable hardware resources of the FPGAs.

  18. Evaluation of actuator energy storage and power sources for spacecraft applications

    NASA Technical Reports Server (NTRS)

    Simon, William E.; Young, Fred M.

    1993-01-01

    The objective of this evaluation is to determine an optimum energy storage/power source combination for electrical actuation systems for existing (Solid Rocket Booster (SRB), Shuttle) and future (Advanced Launch System (ALS), Shuttle Derivative) vehicles. Characteristic of these applications is the requirement for high power pulses (50-200 kW) for short times (milliseconds to seconds), coupled with longer-term base or 'housekeeping' requirements (5-16 kW). Specific study parameters (e.g., weight, volume, etc.) as stated in the proposal and specified in the Statement of Work (SOW) are included.

  19. Flat conductor cable for electrical packaging

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1972-01-01

    Flat conductor cable (FCC) is relatively new, highly promising means for electrical packaging and system integration. FCC offers numerous desirable traits (weight, volume and cost savings, flexibility, high reliability, predictable and repeatable electrical characteristics) which make it extremely attractive as a packaging medium. FCC, today, finds wide application in everything from integration of lunar equipment to the packaging of electronics in nuclear submarines. Described are cable construction and means of termination, applicable specifications and standards, and total FCC systems. A list of additional sources of data is also included for more intensive study.

  20. Insulation Requirements of High-Voltage Power Systems in Future Spacecraft

    NASA Technical Reports Server (NTRS)

    Qureshi, A. Haq; Dayton, James A., Jr.

    1995-01-01

    The scope, size, and capability of the nation's space-based activities are limited by the level of electrical power available. Long-term projections show that there will be an increasing demand for electrical power in future spacecraft programs. The level of power that can be generated, conditioned, transmitted, and used will have to be considerably increased to satisfy these needs, and increased power levels will require that transmission voltages also be increased to minimize weight and resistive losses. At these projected voltages, power systems will not operate satisfactorily without the proper electrical insulation. Open or encapsulated power supplies are currently used to keep the volume and weight of space power systems low and to protect them from natural and induced environmental hazards. Circuits with open packaging are free to attain the pressure of the outer environment, whereas encapsulated circuits are imbedded in insulating materials, which are usually solids, but could be liquids or gases. Up to now, solid insulation has usually been chosen for space power systems. If the use of solid insulation is continued, when voltages increase, the amount of insulation for encapsulation also will have to increase. This increased insulation will increase weight and reduce system reliability. Therefore, non-solid insulation media must be examined to satisfy future spacecraft power and voltage demands. In this report, we assess the suitability of liquid, space vacuum, and gas insulation for space power systems.

  1. A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods.

    PubMed

    Hajiaghaei, Behnam; Ebrahimi, Ismail; Kamyab, Mojtaba; Saeedi, Hassan; Jalali, Maryam

    2016-01-01

    Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.

  2. Assessment of Fetal Kidney Growth and Birth Weight in an Indigenous Australian Cohort.

    PubMed

    Diehm, Christopher J; Lumbers, Eugenie R; Weatherall, Loretta; Keogh, Lyniece; Eades, Sandra; Brown, Alex; Smith, Roger; Johnson, Vanessa; Pringle, Kirsty G; Rae, Kym M

    2017-01-01

    Introduction: Indigenous Australians experience higher rates of renal disease and hypertension than non-Indigenous Australians. Low birth weight is recognized as a contributing factor in chronic disease and has been shown to increase the risk of renal failure in adulthood. A smaller kidney volume with fewer nephrons places an individual at risk of hypertension and renal failure. Indigenous Australians have fewer nephrons than non-Indigenous Australians. In this study, intrauterine fetal and kidney growth were evaluated in 174 Indigenous Australian babies throughout gestation in order to record and evaluate fetal growth and kidney size, within a population that is at high risk for chronic illness. Methods: Pregnant women that identified as Indigenous, or non-Indigenous women that were pregnant with a partner who identified as an Indigenous Australian were eligible to participate. Maternal history, smoking status, blood and urine samples and fetal ultrasounds were collected throughout pregnancy. Fetal kidney measurements were collected using ultrasound. Statistical analysis was performed using the Stata 14.1 software package. Results: 15.2% of babies were born prematurely. 44% of the mothers reported smoking in pregnancy. The median birth weight of this cohort was 3,240 g. Male fetuses had higher kidney to body weight ratios than female fetuses ( P = 0.02). The birth weights of term neonates whose mothers smoked during pregnancy were lower (327 g, P < 0.001) than the birth weights of term babies from non-smoking mothers. The kidney volumes of babies whose mothers smoked were also smaller ( P = 0.02), but were in proportion to body weight. Conclusion: In this cohort of Indigenous women smoking was associated with both increased number of preterm births and with a reduction in birth weights, even of term infants. Since kidney volume is a surrogate measure of nephron number and nephrogenesis is complete at birth, babies whose mothers smoked during pregnancy must have fewer nephrons than those from non-smoking mothers. Previous studies have shown that glomerular filtration rate is not related to birth weight, thus infants with smaller kidney volumes are hyperfiltering from birth and therefore are likely to be more susceptible to early onset renal disease in later life.

  3. Metabolism during hypodynamia

    NASA Technical Reports Server (NTRS)

    Federov, I. V.

    1980-01-01

    Physical immobilization, inaction due to space travel, a sedentary occupation, or bed confinement due to a chronic illness elicit similar alternations in the metabolism of man and animals (rat, rabbit, dog, mouse). After a preliminary period of weight loss, there is eventually weight gain due to increased lipid storage. Protein catabolism is enhanced and anabolism depressed, with elevated urinary excretion of amino acids, creatine, and ammonia. Glycogen stores are depleted and glyconeogenesis is accelerated. Polyuria develops with subsequent redistribution of body fluids in which the blood volume of the systemic circulation is decreased and that of pulmonary circulation increased. This results in depressed production of vasopressin by the posterior pituitary which further enhances urinary water and salt loss.

  4. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Nan-Jie; Wong, Chun-Sing, E-mail: drcswong@gmail.com; Chu, Yiu-Ching

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using themore » proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.« less

  5. Automation of Command and Data Entry in a Glovebox Work Volume: An Evaluation of Data Entry Devices

    NASA Technical Reports Server (NTRS)

    Steele, Marianne K.; Nakamura, Gail; Havens, Cindy; LeMay, Moira

    1996-01-01

    The present study was designed to examine the human-computer interface for data entry while performing experimental procedures within a glovebox work volume in order to make a recommendation to the Space Station Biological Research Project for a data entry system to be used within the Life Sciences Glovebox. Test subjects entered data using either a manual keypad, similar to a standard computer numerical keypad located within the glovebox work volume, or a voice input system using a speech recognition program with a microphone headset. Numerical input and commands were programmed in an identical manner between the two systems. With both electronic systems, a small trackball was available within the work volume for cursor control. Data, such as sample vial identification numbers, sample tissue weights, and health check parameters of the specimen, were entered directly into procedures that were electronically displayed on a video monitor within the glovebox. A pen and paper system with a 'flip-chart' format for procedure display, similar to that currently in use on the Space Shuttle, was used as a baseline data entry condition. Procedures were performed by a single operator; eight test subjects were used in the study. The electronic systems were tested under both a 'nominal' or 'anomalous' condition. The anomalous condition was introduced into the experimental procedure to increase the probability of finding limitations or problems with human interactions with the electronic systems. Each subject performed five test runs during a test day: two procedures each with voice and keypad, one with and one without anomalies, and one pen and paper procedure. The data collected were both quantitative (times, errors) and qualitative (subjective ratings of the subjects).

  6. Fiber optics for advanced aircraft

    NASA Technical Reports Server (NTRS)

    Baumbick, Robert J.

    1989-01-01

    The increased use of composites makes the digital control more susceptible to electromagnetic effects. In order to provide the protection to the digital control additional shielding will be required as well as protective circuitry for the electronics. This results in increased weight and reduced reliability. The advantages that fiber optic technology provides for advanced aircraft applications is recognized. The use of optical signals to carry information between the aircraft and the control module provides immunity from contamination by electromagnetic sources as well as other important benefits such as reduced weight and volume resulting from the elimination of the shielding and the replacement of metal conductors with low weight glass fibers. In 1975 NASA began work to develop passive optical sensors for use with fiber optics in aircraft control systems. The problem now is to choose the best optical sensor concepts and evaluate them for use. In 1985 NASA and DOD entered into a joint program, Fiber Optic Control System Integration (FOCSI), to look at optical technology specifically for use in advanced aircraft systems. The results of this program are discussed. The conclusion of the study indicated that the use of fiber optic technology in advanced aircraft systems is feasible and desirable. The study pointed to a lack of available sensors from vendors capable of operating in the adverse environments of advanced aircraft.

  7. Fiber optics for advanced aircraft

    NASA Technical Reports Server (NTRS)

    Baumbick, Robert J.

    1988-01-01

    The increased use of composites makes the digital control more susceptible to electromagnetic effects. In order to provide the protection to the digital control additional shielding will be required as well as protective circuitry for the electronics. This results in increased weight and reduced reliability. The advantages that fiber optic technology provides for advanced aircraft applications is recognized. The use of optical signals to carry information between the aircraft and the control module provides immunity from contamination by electromagnetic sources as well as other important benefits such as reduced weight and volume resulting from the elimination of the shielding and the replacement of metal conductors with low weight glass fibers. In 1975 NASA began work to develop passive optical sensors for use with fiber optics in aircraft control systems. The problem now is to choose the best optical sensor concepts and evaluate them for use. In 1985 NASA and DOD entered into a joint program, Fiber Optic Control System Integration (FOCSI), to look at optical technology specifically for use in advanced aircraft systems. The results of this program are discussed. The conclusion of the study indicated that the use of fiber optic technology in advanced aircraft systems is feasible and desirable. The study pointed to a lack of available sensors from vendors capable of operating in the adverse environments of advanced aircraft.

  8. Design of H2-O2 space shuttle APU. Volume 1: APU design

    NASA Technical Reports Server (NTRS)

    Harris, E.

    1974-01-01

    The H2-O2 space shuttle auxiliary power unit (APU) program is a NASA-Lewis effort aimed at hardware demonstration of the technology required for potential use on the space shuttle. It has been shown that a hydrogen-oxygen power unit (APU) system is an attractive alternate to the space shuttle baseline hydrazine APU system for minimum weight. It has the capability for meeting many of the heat sink requirements for the space shuttle vehicle, thereby reducing the amount of expendable evaporants required for cooling in the baseline APU. Volume 1 of this report covers preliminary design and analysis of the current reference system and detail design of the test version of this reference system. Combustor test results are also included. Volume 2 contains the results of the analysis of an initial version of the reference system and the computer printouts of system performance. The APU consists of subsystems for propellant feed and conditioning, turbopower, and control. Propellant feed and conditioning contains all heat exchangers, valves, and the combustor. The turbopower subsystem contains a two-stage partial-admission pressure-modulated, 400-hp, 63,000-rpm turbine, a 0-to 4-g lubrication system, and a gearbox with output pads for two hydraulic pumps and an alternator (alternator not included on test unit). The electronic control functions include regulation of speed and system temperatures; and start-and-stop sequences, overspeed (rpm) and temperature limits, failsafe provisions, and automatic shutdown provisions.

  9. Suspended Microchannel Resonators for Ultralow Volume Universal Detection

    PubMed Central

    Son, Sungmin; Grover, William H.; Burg, Thomas P.; Manalis, Scott R.

    2008-01-01

    Universal detectors that maintain high sensitivity as the detection volume is reduced to the subnanoliter scale can enhance the utility of miniaturized total analysis systems (μ-TAS). Here the unique scaling properties of the suspended microchannel resonator (SMR) are exploited to show universal detection in a 10 pL analysis volume with a density detection limit of ∼1 μg/cm3 (10 Hz bandwidth) and a dynamic range of 6 decades. Analytes with low UV extinction coefficients such as polyethylene glycol (PEG) 8 kDa, glucose, and glycine are measured with molar detection limits of 0.66, 13.5, and 31.6 μM, respectively. To demonstrate the potential for real-time monitoring, gel filtration chromatography was used to separate different molecular weights of PEG as the SMR acquired a chromatogram by measuring the eluate density. This work suggests that the SMR could offer a simple and sensitive universal detector for various separation systems from liquid chromatography to capillary electrophoresis. Moreover, since the SMR is itself a microfluidic channel, it can be directly integrated into μ-TAS without compromising overall performance. PMID:18489125

  10. A mouse anti-myostatin antibody increases muscle mass and improves muscle strength and contractility in the mdx mouse model of Duchenne muscular dystrophy and its humanized equivalent, domagrozumab (PF-06252616), increases muscle volume in cynomolgus monkeys.

    PubMed

    St Andre, Michael; Johnson, Mark; Bansal, Prashant N; Wellen, Jeremy; Robertson, Andrew; Opsahl, Alan; Burch, Peter M; Bialek, Peter; Morris, Carl; Owens, Jane

    2017-11-09

    The treatments currently approved for Duchenne muscular dystrophy (DMD), a progressive skeletal muscle wasting disease, address the needs of only a small proportion of patients resulting in an urgent need for therapies that benefit all patients regardless of the underlying mutation. Myostatin is a member of the transforming growth factor-β (TGF-β) family of ligands and is a negative regulator of skeletal muscle mass. Loss of myostatin has been shown to increase muscle mass and improve muscle function in both normal and dystrophic mice. Therefore, myostatin blockade via a specific antibody could ameliorate the muscle weakness in DMD patients by increasing skeletal muscle mass and function, thereby reducing patients' functional decline. A murine anti-myostatin antibody, mRK35, and its humanized analog, domagrozumab, were developed and their ability to inhibit several TGB-β ligands was measured using a cell-based Smad-activity reporter system. Normal and mdx mice were treated with mRK35 to examine the antibody's effect on body weight, lean mass, muscle weights, grip strength, ex vivo force production, and fiber size. The humanized analog (domagrozumab) was tested in non-human primates (NHPs) for changes in skeletal muscle mass and volume as well as target engagement via modulation of circulating myostatin. Both the murine and human antibodies are specific and potent inhibitors of myostatin and GDF11. mRK35 is able to increase body weight, lean mass, and muscle weights in normal mice. In mdx mice, mRK35 significantly increased body weight, muscle weights, grip strength, and ex vivo force production in the extensor digitorum longus (EDL) muscle. Further, tibialis anterior (TA) fiber size was significantly increased. NHPs treated with domagrozumab demonstrated a dose-dependent increase in lean mass and muscle volume and exhibited increased circulating levels of myostatin demonstrating target engagement. We demonstrated that the potent anti-myostatin antibody mRK35 and its clinical analog, domagrozumab, were able to induce muscle anabolic activity in both rodents, including the mdx mouse model of DMD, and non-human primates. A Phase 2, potentially registrational, clinical study with domagrozumab in DMD patients is currently underway.

  11. Investigating structural brain changes of dehydration using voxel-based morphometry.

    PubMed

    Streitbürger, Daniel-Paolo; Möller, Harald E; Tittgemeyer, Marc; Hund-Georgiadis, Margret; Schroeter, Matthias L; Mueller, Karsten

    2012-01-01

    Dehydration can affect the volume of brain structures, which might imply a confound in volumetric and morphometric studies of normal or diseased brain. Six young, healthy volunteers were repeatedly investigated using three-dimensional T(1)-weighted magnetic resonance imaging during states of normal hydration, hyperhydration, and dehydration to assess volume changes in gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The datasets were analyzed using voxel-based morphometry (VBM), a widely used voxel-wise statistical analysis tool, FreeSurfer, a fully automated volumetric segmentation measure, and SIENAr a longitudinal brain-change detection algorithm. A significant decrease of GM and WM volume associated with dehydration was found in various brain regions, most prominently, in temporal and sub-gyral parietal areas, in the left inferior orbito-frontal region, and in the extra-nuclear region. Moreover, we found consistent increases in CSF, that is, an expansion of the ventricular system affecting both lateral ventricles, the third, and the fourth ventricle. Similar degrees of shrinkage in WM volume and increase of the ventricular system have been reported in studies of mild cognitive impairment or Alzheimer's disease during disease progression. Based on these findings, a potential confound in GM and WM or ventricular volume studies due to the subjects' hydration state cannot be excluded and should be appropriately addressed in morphometric studies of the brain.

  12. Investigating Structural Brain Changes of Dehydration Using Voxel-Based Morphometry

    PubMed Central

    Streitbürger, Daniel-Paolo; Möller, Harald E.; Tittgemeyer, Marc; Hund-Georgiadis, Margret; Schroeter, Matthias L.; Mueller, Karsten

    2012-01-01

    Dehydration can affect the volume of brain structures, which might imply a confound in volumetric and morphometric studies of normal or diseased brain. Six young, healthy volunteers were repeatedly investigated using three-dimensional T 1-weighted magnetic resonance imaging during states of normal hydration, hyperhydration, and dehydration to assess volume changes in gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The datasets were analyzed using voxel-based morphometry (VBM), a widely used voxel-wise statistical analysis tool, FreeSurfer, a fully automated volumetric segmentation measure, and SIENAr a longitudinal brain-change detection algorithm. A significant decrease of GM and WM volume associated with dehydration was found in various brain regions, most prominently, in temporal and sub-gyral parietal areas, in the left inferior orbito-frontal region, and in the extra-nuclear region. Moreover, we found consistent increases in CSF, that is, an expansion of the ventricular system affecting both lateral ventricles, the third, and the fourth ventricle. Similar degrees of shrinkage in WM volume and increase of the ventricular system have been reported in studies of mild cognitive impairment or Alzheime s disease during disease progression. Based on these findings, a potential confound in GM and WM or ventricular volume studies due to the subjects’ hydration state cannot be excluded and should be appropriately addressed in morphometric studies of the brain. PMID:22952926

  13. High voltage requirements and issues for the 1990's. [for spacecraft power supplies

    NASA Technical Reports Server (NTRS)

    Dunbar, W. G.; Faymon, K. A.

    1984-01-01

    The development of high-power high-voltage space systems will require advances in power generation and processing. The systems must be reliable, adaptable, and durable for space mission success. The issues, which must be resolved in order to produce a high power system, are weight and volume reduction of components and modules and the creation of a reliable high repetition pulse power processor. Capacitor energy density must be increased by twice the present capacity and packaging must be reduced by a factor of 10 to 20 times. The packaging must also protect the system from interaction with the natural space environment and the induced environment, produced from spacecraft systems and environment interaction.

  14. Space vehicle integrated thermal protection/structural/meteoroid protection system, volume 1

    NASA Technical Reports Server (NTRS)

    Bartlett, D. H.; Zimmerman, D. K.

    1973-01-01

    A program was conducted to determine the merit of a combined structure/thermal meteoroid protection system for a cryogenic vehicle propulsion module. Structural concepts were evaluated to identify least weight designs. Thermal analyses determined optimum tank arrangements and insulation materials. Meteoroid penetration experiments provided data for design of protection systems. Preliminary designs were made and compared on the basis of payload capability. Thermal performance tests demonstrated heat transfer rates typical for the selected design. Meteoroid impact tests verified the protection characteristics. A mockup was made to demonstrate protection system installation. The best design found combined multilayer insulation with a truss structure vehicle body. The multilayer served as the thermal/meteoroid protection system.

  15. Effects of growth, diving history, and high altitude on blood oxygen capacity in harbor seals

    NASA Technical Reports Server (NTRS)

    Kodama, A. M.; Elsner, R.; Pace, N.

    1977-01-01

    Blood volume and body composition for diving and nondiving harbor seals were measured at six-week intervals during a 10-month period of captitivity. Whole body hematocrit, red cell volume per kg of lean body mass, and total circulating hemoglobin per kg lean body mass were significantly higher in the diving group, but relatively large blood volumes expressed in terms of body weight (11-12%) were found in both groups. A pair of harbor seals exposed to high altitude for about three months registered significant increases in red cell volume, blood hemoglobin levels, and blood volume expressed in terms of body weight; results of alveolar gas analyses indicate that hyperventilation also occurred. These typical mammalian responses to hypoxia suggest that the harbor seal's large blood volume and high hemoglobin content are an expression of phylogenetic control, and that in spite of its adaptability to apnea during its diving life, the animal cannot be considered preacclimatized to high altitude.

  16. Lung gas volumes and expiratory time constant in immature newborn rabbits treated with natural or synthetic surfactant or detergents.

    PubMed

    Bongrani, S; Fornasier, M; Papotti, M; Razzetti, R; Robertson, B

    1994-01-01

    Immature newborn rabbits delivered at a gestational age of 27 days were tracheotomized and treated, via the tracheal cannula, with clinically recommended doses of natural or synthetic surfactant (Curosurf and Exosurf, respectively). Littermates received 0.1% tyloxapol, 5% Tween 20, or saline. The dose volume of Curosurf was 2.5 ml/kg, that of the other materials 5 ml/kg. Animals were kept in a multiplethysmograph system and ventilated for 30 min with a standardized sequence of insufflation pressures. End-expiratory lung gas volume was calculated at the end of the experiment from measurements of lung weight and total lung volume. Tidal volumes were significantly improved in all groups of animals receiving surfactant or detergents. However, expiratory time constant (determined from the tidal volume tracing) was significantly longer, and end-expiratory gas volume significantly larger, in animals treated with Curosurf than in those receiving Exosurf or detergents. These differences were confirmed by semiquantitative evaluation of alveolar air expansion in histological sections. In addition, airway epithelial necrosis was reduced in animals receiving Curosurf, Exosurf, or Tween 20, but not in animals treated with tyloxapol. The discrepancy between improvements in tidal volume, expiratory time constant, and end-expiratory gas volume reflects failure of lung stabilization in animals treated with Exosurf or detergents, probably due to absence of specific hydrophobic proteins in the synthetic products.

  17. Wood decay by brown-rot fungi : changes in pore structure and cell wall volume

    Treesearch

    Douglas S. Flournoy; T. Kent Kirk; T.L. Highley

    1991-01-01

    Sweetgum (Liquidambar styraciflua L.) wood blocks were decayed by Postia (= Poria) placenta in soilblock cultures. Decay was terminated at various weight losses, and the pore volumes available to four low molecular weight molecules, (water, 4 Å,; glucose, 8 Å,; maltose, 10 Å; and raffinose, 128,) and three dextrans (Mr 6,000, 38 Å; 11,200, 51 Å; nd 17,500, 61 Å) were...

  18. A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ajani, Abdallah A.; Qureshi, Muhammad M.; Kovalchuk, Nataliya

    To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recordedmore » at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.« less

  19. Use of spiral computed tomography volumetry for determining the operative approach in patients with Graves' disease.

    PubMed

    Choi, June Young; Lee, Kyu Eun; Koo, Do Hoon; Kim, Kyu Hyung; Kim, Eun young; Bae, Dong Sik; Jung, Sung Eun; Youn, Yeo-Kyu

    2014-03-01

    The purposes of the present study were to assess (1) the correlation between the weight of the postoperative thyroid specimen and the spiral computed tomography (CT) volumetry results of the thyroid gland in patients with Graves' disease, and (2) the utility of CT volumetry for determining the operative approach. From 2009 to 2010, a total of 56 patients with Graves' disease underwent total or subtotal thyroidectomy. An enhanced spiral CT was taken in all patients prior to the operation. From 2.5 mm-thick slices of the thyroid gland, the surface area was calculated to measure the volume of the thyroid gland. The glandular volume was compared to the weight of the postoperative thyroid specimen. A total of 42 and 14 patients underwent total and subtotal thyroidectomy, respectively. The mean weight of the postoperative thyroid specimen was 43.9 ± 33.4 g, and the mean volume obtained by CT volumetry was 44.2 ± 32.8 mL. A good correlation was observed between the weight of the postoperative thyroid specimen and the volume calculated by CT (r = 0.98, p < 0.001). When 100 mL was set as the higher cut-off value of the thyroid volume for minimally invasive thyroid surgery, the estimated blood loss showed a significant difference between the >100 mL and the ≤100 mL groups (608.3 ± 540.8 vs. 119.7 ± 110.4 mL; p = 0.036). Spiral CT volumetry may be used to measure the thyroid volume reliably in patients with Graves' disease. For cases in which surgery is indicated in patients with Graves' disease, CT volumetry provides useful information from which to determine the operative approach. One hundred milliliter or less of thyroid volume in CT volumetry is recommended to perform minimally invasive thyroid surgery.

  20. Liver Volumetry Plug and Play: Do It Yourself with ImageJ

    PubMed Central

    Dello, Simon A. W. G.; van Dam, Ronald M.; Slangen, Jules J. G.; van de Poll, Marcel C. G.; Bemelmans, Marc H. A.; Greve, Jan Willem W. M.; Beets-Tan, Regina G. H.; Wigmore, Stephen J.

    2007-01-01

    Background A small remnant liver volume is an important risk factor for posthepatectomy liver failure and can be predicted accurately by computed tomography (CT) volumetry using radiologic image analysis software. Unfortunately, this software is expensive and usually requires support by a radiologist. ImageJ is a freely downloadable image analysis software package developed by the National Institute of Health (NIH) and brings liver volumetry to the surgeon’s desktop. We aimed to assess the accuracy of ImageJ for hepatic CT volumetry. Methods ImageJ was downloaded from http://www.rsb.info.nih.gov/ij/. Preoperative CT scans of 15 patients who underwent liver resection for colorectal cancer liver metastases were retrospectively analyzed. Scans were opened in ImageJ; and the liver, all metastases, and the intended parenchymal transection line were manually outlined on each slice. The area of each selected region, metastasis, resection specimen, and remnant liver was multiplied by the slice thickness to calculate volume. Volumes of virtual liver resection specimens measured with ImageJ were compared with specimen weights and calculated volumes obtained during pathology examination after resection. Results There was an excellent correlation between the volumes calculated with ImageJ and the actual measured weights of the resection specimens (r² = 0.98, p < 0.0001). The weight/volume ratio amounted to 0.88 ± 0.04 (standard error) and was in agreement with our earlier findings using CT-linked radiologic software. Conclusion ImageJ can be used for accurate hepatic CT volumetry on a personal computer. This application brings CT volumetry to the surgeon’s desktop at no expense and is particularly useful in cases of tertiary referred patients, who already have a proper CT scan on CD-ROM from the referring institution. Most likely the discrepancy between volume and weight results from exsanguination of the liver after resection. PMID:17726630

  1. Preparation and biocompatibility study of in situ forming polymer implants in rat brains.

    PubMed

    Nasongkla, Norased; Boongird, Atthaporn; Hongeng, Suradej; Manaspon, Chawan; Larbcharoensub, Noppadol

    2012-02-01

    We describe the development of polymer implants that were designed to solidify once injected into rat brains. These implants comprised of glycofurol and copolymers of D: ,L: -lactide (LA), ε-caprolactone and poly(ethylene glycol) (PLECs). Scanning electron microscopy (SEM) and gel permeation chromatography (GPC) showed that the extent of implant degradation was increased with LA: content in copolymers. SEM analysis revealed the formation of porosity on implant surface as the degradation proceeds. PLEC with 19.3% mole of LA: was chosen to inject in rat brains at the volume of 10, 25 and 40 μl. Body weights, hematological and histopathological data of rats treated with implants were evaluated on day 3, 6, 14, 30 and 45 after the injection. Polymer solution at the injection volume of 10 μl were tolerated relatively well compared to those of 25 and 40 μl as confirmed by higher body weight and healing action (fibrosis tissue) 30 days after treatment. The results from this study suggest a possible application as drug delivery systems that can bypass the blood brain barrier.

  2. A Design Tool for the Evaluation of Atmosphere Independent Propulsion in Submarines

    DTIC Science & Technology

    1994-05-01

    structure«<"\\t\\ tMobility :\\tW’" «<weight _mobility« ’Vi’ cout «<"\\tWeapons:\\t"<«weight...weapofls< h\\t\\tCA 31I:\\t\\t\\t" «<weightc.pcubed_i< "inl; cout...pm << "\\tWeapons:\\t"«<volume_weapons«<"\\t\\ tMobility :\\t\\t" «<volume -mobility<< Wn; pmn « "\\tShip Support:\\t"«<volume -ship support«< n\\tCA 31:\\t\\t\\t

  3. Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis.

    PubMed

    Neto, Ary Serpa; Simonis, Fabienne D; Barbas, Carmen S V; Biehl, Michelle; Determann, Rogier M; Elmer, Jonathan; Friedman, Gilberto; Gajic, Ognjen; Goldstein, Joshua N; Linko, Rita; Pinheiro de Oliveira, Roselaine; Sundar, Sugantha; Talmor, Daniel; Wolthuis, Esther K; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2015-10-01

    Protective mechanical ventilation with low tidal volumes is standard of care for patients with acute respiratory distress syndrome. The aim of this individual patient data analysis was to determine the association between tidal volume and the occurrence of pulmonary complications in ICU patients without acute respiratory distress syndrome and the association between occurrence of pulmonary complications and outcome in these patients. Individual patient data analysis. ICU patients not fulfilling the consensus criteria for acute respiratory distress syndrome at the onset of ventilation. Mechanical ventilation with low tidal volume. The primary endpoint was development of a composite of acute respiratory distress syndrome and pneumonia during hospital stay. Based on the tertiles of tidal volume size in the first 2 days of ventilation, patients were assigned to a "low tidal volume group" (tidal volumes ≤ 7 mL/kg predicted body weight), an "intermediate tidal volume group" (> 7 and < 10 mL/kg predicted body weight), and a "high tidal volume group" (≥ 10 mL/kg predicted body weight). Seven investigations (2,184 patients) were included. Acute respiratory distress syndrome or pneumonia occurred in 23% of patients in the low tidal volume group, in 28% of patients in the intermediate tidal volume group, and in 31% of the patients in the high tidal volume group (adjusted odds ratio [low vs high tidal volume group], 0.72; 95% CI, 0.52-0.98; p = 0.042). Occurrence of pulmonary complications was associated with a lower number of ICU-free and hospital-free days and alive at day 28 (10.0 ± 10.9 vs 13.8 ± 11.6 d; p < 0.01 and 6.1 ± 8.1 vs 8.9 ± 9.4 d; p < 0.01) and an increased hospital mortality (49.5% vs 35.6%; p < 0.01). Ventilation with low tidal volumes is associated with a lower risk of development of pulmonary complications in patients without acute respiratory distress syndrome.

  4. System optimization on coded aperture spectrometer

    NASA Astrophysics Data System (ADS)

    Liu, Hua; Ding, Quanxin; Wang, Helong; Chen, Hongliang; Guo, Chunjie; Zhou, Liwei

    2017-10-01

    For aim to find a simple multiple configuration solution and achieve higher refractive efficiency, and based on to reduce the situation disturbed by FOV change, especially in a two-dimensional spatial expansion. Coded aperture system is designed by these special structure, which includes an objective a coded component a prism reflex system components, a compensatory plate and an imaging lens Correlative algorithms and perfect imaging methods are available to ensure this system can be corrected and optimized adequately. Simulation results show that the system can meet the application requirements in MTF, REA, RMS and other related criteria. Compared with the conventional design, the system has reduced in volume and weight significantly. Therefore, the determining factors are the prototype selection and the system configuration.

  5. Partial Reductions in Mechanical Loading Yield Proportional Changes in Bone Density, Bone Architecture, and Muscle Mass

    PubMed Central

    Ellman, Rachel; Spatz, Jordan; Cloutier, Alison; Palme, Rupert; Christiansen, Blaine A; Bouxsein, Mary L

    2014-01-01

    Although the musculoskeletal system is known to be sensitive to changes in its mechanical environment, the relationship between functional adaptation and below-normal mechanical stimuli is not well defined. We investigated bone and muscle adaptation to a range of reduced loading using the partial weight suspension (PWS) system, in which a two-point harness is used to offload a tunable amount of body weight while maintaining quadrupedal locomotion. Skeletally mature female C57Bl/6 mice were exposed to partial weight bearing at 20%, 40%, 70%, or 100% of body weight for 21 days. A hindlimb unloaded (HLU) group was included for comparison in addition to age-matched controls in normal housing. Gait kinematics was measured across the full range of weight bearing, and some minor alterations in gait from PWS were identified. With PWS, bone and muscle changes were generally proportional to the degree of unloading. Specifically, total body and hindlimb bone mineral density, calf muscle mass, trabecular bone volume of the distal femur, and cortical area of the femur midshaft were all linearly related to the degree of unloading. Even a load reduction to 70% of normal weight bearing was associated with significant bone deterioration and muscle atrophy. Weight bearing at 20% did not lead to better bone outcomes than HLU despite less muscle atrophy and presumably greater mechanical stimulus, requiring further investigation. These data confirm that the PWS model is highly effective in applying controllable, reduced, long-term loading that produces predictable, discrete adaptive changes in muscle and bone of the hindlimb. PMID:23165526

  6. Advanced information processing system: The Army fault tolerant architecture conceptual study. Volume 2: Army fault tolerant architecture design and analysis

    NASA Technical Reports Server (NTRS)

    Harper, R. E.; Alger, L. S.; Babikyan, C. A.; Butler, B. P.; Friend, S. A.; Ganska, R. J.; Lala, J. H.; Masotto, T. K.; Meyer, A. J.; Morton, D. P.

    1992-01-01

    Described here is the Army Fault Tolerant Architecture (AFTA) hardware architecture and components and the operating system. The architectural and operational theory of the AFTA Fault Tolerant Data Bus is discussed. The test and maintenance strategy developed for use in fielded AFTA installations is presented. An approach to be used in reducing the probability of AFTA failure due to common mode faults is described. Analytical models for AFTA performance, reliability, availability, life cycle cost, weight, power, and volume are developed. An approach is presented for using VHSIC Hardware Description Language (VHDL) to describe and design AFTA's developmental hardware. A plan is described for verifying and validating key AFTA concepts during the Dem/Val phase. Analytical models and partial mission requirements are used to generate AFTA configurations for the TF/TA/NOE and Ground Vehicle missions.

  7. The protective effect of dexpanthenol on testicular atrophy at 60th day following experimental testicular torsion.

    PubMed

    Etensel, Barlas; Ozkisacik, Sezen; Ozkara, Esra; Serbest, Yeşim Aksu; Oztan, Onur; Yazici, Mesut; Gürsoy, Harun

    2007-03-01

    Despite the prompt diagnosis and treatment of testicular torsion (TT), there are problems with fertility and atrophy after testicular salvage. Dexpanthenol (Dxp) is the biologically active alcohol of pantothenic acid (PA). Dxp is converted to PA in tissues. PA increases the content of reduced glutathione (GSH), Coenzyme A and ATP synthesis in cells. GSH and glutathione-dependent peroxidases (GPX) are the major defense systems against oxidative stress. GPX-4 is the major antioxidant in testicular tissue. However, the activity of GPX-4 appeared and increased only after puberty. We investigated the effect of Dxp on testicular atrophy after TT at the 60th day. Rats were separated randomly into four groups. Group C: control group, group Td: torsion + detorsion, group Sal: torsion + saline + detorsion, group Dxp: torsion + Dxp + detorsion. The left testis was rotated 720 degrees for 2 h. In group Sal, normal saline and in group Dxp, Dexpanthenol were injected intraperitonally, 30 min before detorsion. After 60 days, the testicular weights and volumes were measured. Histopathology of the left testis was evaluated with mean seminiferous tubular diameter (MSTD) and mean testicular biopsy score (MTBS). The left (torsed) testicular weight and volume of groups Td and Sal were significantly lower compared to group Dxp. The MSTD and MTBS of group Td and Sal were significantly lower than group Dxp. Contralateral testicular weight and volume of groups Td, Sal and Dxp had no significant difference compared to the control group. Dxp significantly prevented testicular atrophy after 60 days of TT. Dxp has FDA approval, is safe, cost effective and readily available. Its relevance for clinical trials may especially be for the problem of testicular atrophy catastrophe, seen very frequently following testicular salvage.

  8. Harvests from bone marrow donors who weigh less than their recipients are associated with a significantly increased probability of a suboptimal harvest yield.

    PubMed

    Anthias, Chloe; Billen, Annelies; Arkwright, Rebecca; Szydlo, Richard M; Madrigal, J Alejandro; Shaw, Bronwen E

    2016-05-01

    Previous studies have demonstrated the importance of bone marrow (BM) harvest yield in determining transplant outcomes, but little is known regarding donor and procedure variables associated with achievement of an optimal yield. We hypothesized that donor demographics and variables relating to the procedure were likely to impact the yield (total nucleated cells [TNCs]/kg recipient weight) and quality (TNCs/mL) of the harvest. To test our hypothesis, BM harvests of 110 consecutive unrelated donors were evaluated. The relationship between donor or procedure characteristics and the BM harvest yield was examined. The relationship between donor and recipient weight significantly influenced the harvest yield; only 14% of BM harvests from donors who weighed less than their recipient achieved a TNC count of more than 4 × 10(8) /kg compared to 56% of harvests from donors heavier than their recipient (p = 0.001). Higher-volume harvests were significantly less likely to achieve an optimal yield than lower-volume harvests (32% vs. 78%; p = 0.007), and higher-volume harvests contained significantly fewer TNCs/mL, indicating peripheral blood contamination. BM harvest quality also varied significantly between collection centers adding to recent concerns regarding maintenance of BM harvest expertise within the transplant community. Since the relationship between donor and recipient weight has a critical influence yield, we recommend prioritizing this secondary donor characteristic when selecting from multiple well-matched donors. Given the declining number of requests for BM harvests, it is crucial that systems are developed to train operators and ensure expertise in this procedure is retained. © 2016 AABB.

  9. Pacific Northwest residential energy survey. Volume 3. Question-by-question results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-07-01

    Tabulations are presented of responses to approximately 105 questions. Results are tabulated by 9 geographic regions: the four states of Idaho, Montana, Oregon, and Washington; four climate zones in the region; and a weighted Pacific Northwest total. A description of the tabulated data is given in the Introduction. Tabulated data deal with questions on dwelling characteristics; heating and air-conditioning systems; water heating; appliances; demographic and swelling characteristics; and insulation.

  10. JPRS Report, Soviet Union KOMMUNIST No 1, January 1988.

    DTIC Science & Technology

    1988-03-24

    the live creativity of the masses is the fundamental factor of the new social system which is being developed currently. The entire people, as...average annual volume of meat produc- tion (in slaughtered weight) increased by 13 percent and that of milk by 9 percent compared with the 11th 5 -year...standards for the 5 -year period is their strength and, in the final account, indi- cates the viability of the new

  11. The 1985 Army Experience Survey: Tabular Descriptions of First-Term Attritees. Volume 2

    DTIC Science & Technology

    1986-01-01

    survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The coding schemes developed to classify... R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY. .. ................. 272-273 049 El37 U TERMS OF ACTIVE ENLISTMENT .. ........ ................ 274...272 R136 -- REGION OF RESIDENCE WHEN YOU JOINED ARMY RECODED - WHAT STATE WERE YOU LIVING IN WHEN YOU JOINED THE ARMY! (RECODED TO REGION OF RSID) I

  12. The 1985 Army Experience Survey: Tabular Descriptions of Enlisted Retirees. Volume 1

    DTIC Science & Technology

    1986-01-01

    processed through survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The coding schemes...222-223 047A R135 AGE OF OLDEST CHILD .............-.-.-.-.-.-.-.-.-.-.-.-... . 224-225 048 R136 REGION OF RESIDENCE WHEN... R136 -- REGION OF RESIDENCE WHEN YOU JOINED ARMY 7 RECODED - WHAT STATE WERE YOU LIVING IN WHEN YOU JOItNED THE ARMY? (RECODED TO REGION OF RSID) I

  13. Portable oxygen subsystem. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The concept and design of a portable oxygen device for use in the space shuttle orbiter is presented. Hardware fabrication and acceptance tests (i.e., breadboard models) are outlined and discussed. Optimization of the system (for weight, volume, safety, costs) is discussed. The device is of the rebreather type, and provides a revitalized breathing gas supply to a crewman for denitrogenization and emergency activities. Engineering drawings and photographs of the device are shown.

  14. Numerical Simulation of Pulse Detonation Rocket-Induced MHD Ejector (PDRIME) Concepts for Advanced Propulsion Systems

    DTIC Science & Technology

    2012-02-28

    Coupling in Detonation Waves: 1D Dynamics”, Paper 89, 23rd International Colloquium on the Dynamics of Explosions and Reactive ...and temperature, and can be modeled as a constant volume reaction , which is more efficient than a constant pressure reaction . After the detonation ... kinetics , and flow processes using high order numerical methods. A fifth-order WENO (weighted essentially non -oscillatory12,13) scheme was used

  15. Lightweight Towed Howitzer Demonstrator. Phase 1 and Partial Phase 2. Volume D1. Part 2. Structural Analysis (Less Cradle and System).

    DTIC Science & Technology

    1987-04-01

    toleranze. The anisotropic Lai rr-erial was analyzed in a ply-by-ply fashion. R’ ecommendati ons wer e made for desiqn chanoes wh ic h Co0Ul1.d red’jc...weight. reduce? strains and increase stiffness. 1. The atuo e process was repeated with data modifications to ref!E:t the desired design chanoes

  16. High-authority smart material integrated electric actuator

    NASA Astrophysics Data System (ADS)

    Weisensel, G. N.; Pierce, Thomas D.; Zunkel, Gary

    1997-05-01

    For many current applications, hydraulic power is still the preferred method of gaining mechanical advantage. However, in many of these applications, this power comes with the penalties of high weight, size, cost, and maintenance due to the system's distributed nature and redundancy requirements. A high authority smart material Integrated Electric Actuator (IEA) is a modular, self-contained linear motion device that is capable of producing dynamic output strokes similar to those of hydraulic actuators yet at significantly reduced weight and volume. It provides system simplification and miniaturization. This actuator concept has many innovative features, including a TERFENOL-D-based pump, TERFENOL-D- based active valves, control algorithms, a displacement amplification unit and integrated, unitized packaging. The IEA needs only electrical power and a control command signal as inputs to provide high authority, high response rate actuation. This approach is directly compatible with distributed control strategies. Aircraft control, automotive brakes and fuel injection, and fluid power delivery are just some examples of the IEA's pervasive applications in aerospace, defense and commercial systems.

  17. Direct and indirect selection of visceral lipid weight, fillet weight, and fillet percentage in a rainbow trout breeding program.

    PubMed

    Kause, A; Paananen, T; Ritola, O; Koskinen, H

    2007-12-01

    We assessed whether visceral lipid weight, fillet weight, and percentage fillet from BW, 3 traits laborious to record, could be genetically improved by indirect selection on more easily measured traits in farmed rainbow trout. Visceral lipid is discarded as waste during slaughter, influencing production efficiency and production costs. Fillet weight and fillet percentage directly influence economic returns in trout production. The study comprised 3 steps. First, we assessed the degree to which selection on percentage of visceral weight from BW indirectly changes visceral lipid weight and the size of intestines and internal organs. The phenotypic analysis of weights of viscera, intestines, visceral lipid, liver, and gonads measured from 40 fish revealed that phenotypic selection against visceral weight was most strongly directed to visceral lipid, and to a lesser degree to intestines and gonads. Because genetic relationships among these traits were not established, it is not known whether indirect selection leads to genetic responses. Second, we examined whether direct selection for the fillet traits could be replaced by indirect selection on BW, eviscerated BW, visceral weight, visceral percentage, head volume, and relative head volume (head volume relative to BW). The selection index calculations based on the quantitative genetic parameters obtained from multigenerational pedigree data showed that genetic improvement of fillet percentage through direct selection (selection accuracy, r(TI) = 0.54) was equally efficient compared with indirect selection on visceral percentage ( r(TI) = 0.54). Genetic improvement of fillet weight through direct selection (r(TI) = 0.56) was always more efficient than indirect selection, yet indirect selection for eviscerated BW ( r(TI) = 0.50) was almost as efficient as direct selection. Third, the expected genetic responses to alternative selection indices showed that improved fillet percentage was mainly a result of a moderate decrease in visceral weight rather than of a major increase in absolute fillet weight. Moreover, fillet percentage is challenging to improve, even if it exhibits moderate heritability (h(2) = 0.29). This is because fillet percentage displays low phenotypic variation. In conclusion, fillet weight and fillet percentage can be increased by indirect selection against visceral percentage and for high eviscerated BW.

  18. Prediction of distribution volume of vancomycin in critically ill patients using extravascular lung water and pulmonary vascular permeability indices.

    PubMed

    Imaura, Masaharu; Yokoyama, Haruko; Kohyama, Tomoki; Nagafuchi, Hiroyuki; Kohata, Yuji; Takahashi, Hiroyuki; Yamada, Yasuhiko

    2012-11-01

    Alterations in distribution volume affect the concentrations of hydrophilic drugs in plasma and tissues at the time of initial therapy. When the distribution volume of hydrophilic antimicrobials is increased in critically ill patients with a serious infection, antimicrobial concentrations are reduced, which may adversely affect the efficacy of antimicrobial therapy. A transpulmonary thermodilution technique system (PiCCO) enables measurements of pulmonary vascular permeability index (PVPI) and extravascular lung water index (EVLWI), which are related to pulmonary edema and pulmonary vascular permeability, respectively. In addition, those indices may also be related to the distribution volume of hydrophilic antimicrobials. The aim of this study was to investigate the relationships of PVPI and EVLWI with the distribution volume of vancomycin (Vss), as well as to establish a method for estimating Vss for planning an appropriate initial dose for individual patients. Seven patients were administered vancomycin intravenously and underwent extended hemodynamic monitoring with the PiCCO system in the intensive care unit (ICU) from April 2009 to March 2011. Vss was calculated using the Bayesian method, and the relationships of PVPI and EVLWI with Vss were investigated. The relationship between Vss/actual body weight (ABW) and median EVLWI on days when blood levels were measured was significant (r = 0.900, p = 0.0057), whereas the relationship between Vss/ABW and PVPI was not significant (r = 0.649, p = 0.1112). EVLWI determined by the PiCCO system is useful to predict Vss and should lead to more effective vancomycin therapy for critically ill patients at the initial stage.

  19. Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.

    PubMed

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  20. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    PubMed Central

    Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Objective Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Materials and Methods Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. Results A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. Conclusion The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials. PMID:22778560

  1. Accuracy of tidal breathing measurement of FloRight compared to an ultrasonic flowmeter in infants.

    PubMed

    Petrus, Nicole C M; Thamrin, Cindy; Fuchs, Oliver; Frey, Urs

    2015-04-01

    Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements. © 2014 Wiley Periodicals, Inc.

  2. [Decontamination of chemical and biological warfare agents].

    PubMed

    Seto, Yasuo

    2009-01-01

    Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.

  3. Compressive hyperspectral sensor for LWIR gas detection

    NASA Astrophysics Data System (ADS)

    Russell, Thomas A.; McMackin, Lenore; Bridge, Bob; Baraniuk, Richard

    2012-06-01

    Focal plane arrays with associated electronics and cooling are a substantial portion of the cost, complexity, size, weight, and power requirements of Long-Wave IR (LWIR) imagers. Hyperspectral LWIR imagers add significant data volume burden as they collect a high-resolution spectrum at each pixel. We report here on a LWIR Hyperspectral Sensor that applies Compressive Sensing (CS) in order to achieve benefits in these areas. The sensor applies single-pixel detection technology demonstrated by Rice University. The single-pixel approach uses a Digital Micro-mirror Device (DMD) to reflect and multiplex the light from a random assortment of pixels onto the detector. This is repeated for a number of measurements much less than the total number of scene pixels. We have extended this architecture to hyperspectral LWIR sensing by inserting a Fabry-Perot spectrometer in the optical path. This compressive hyperspectral imager collects all three dimensions on a single detection element, greatly reducing the size, weight and power requirements of the system relative to traditional approaches, while also reducing data volume. The CS architecture also supports innovative adaptive approaches to sensing, as the DMD device allows control over the selection of spatial scene pixels to be multiplexed on the detector. We are applying this advantage to the detection of plume gases, by adaptively locating and concentrating target energy. A key challenge in this system is the diffraction loss produce by the DMD in the LWIR. We report the results of testing DMD operation in the LWIR, as well as system spatial and spectral performance.

  4. Altered sexually dimorphic nucleus of the preoptic area (SDN-POA) volume in adult Long-Evans rats by dietary soy phytoestrogens.

    PubMed

    Lund, T D; Rhees, R W; Setchell, K D; Lephart, E D

    2001-09-28

    Naturally occurring estrogen-like molecules in plants (phytoestrogens), present via soy, in animal diets can alter morphology and physiology in rodents. Phytoestrogens have the ability to bind estrogen receptors and exert many of the biological responses evoked by physiological estrogens. This study characterized the effects of dietary phytoestrogens on the expression of body and prostate weight, circulating testosterone and estradiol levels, puberty onset, vaginal cyclicity, and volume of the sexually dimorphic nucleus of the preoptic area (SDN-POA) in Long-Evans rats. Using different experimental protocols, animals were fed either a phytoestrogen-rich (Phyto-600) or a phytoestrogen-free (Phyto-free) diet. Animals fed the Phyto-600 diet displayed significantly decreased body weights (in males and females), prostate weights and delayed puberty in females compared to that of animals fed the Phyto-free diet. Circulating testosterone or estradiol levels in males or estrous cyclicity were not altered by the diets. The volume of the SDN-POA was significantly altered by a change in diet at 80 days of age where one-half of the males or females fed the Phyto-600 diet (from birth) were switched to the Phyto-free diet until 120 days of age. Males initially fed a Phyto-600 diet but changed to a Phyto-free diet had significantly smaller SDN-POA volumes compared to males fed the Phyto-600 diet (long-term). These data suggest that consumption of phytoestrogens via a soy diet, significantly: (1) decreases body and prostate weight, (2) delays puberty onset, and (3) alters SDN-POA volumes during adulthood.

  5. Subcutaneous fat loss is greater than visceral fat loss with diet and exercise, weight-loss promoting drugs and bariatric surgery: a critical review and meta-analysis.

    PubMed

    Merlotti, C; Ceriani, V; Morabito, A; Pontiroli, A E

    2017-05-01

    Aim of this review is to compare visceral and subcutaneous fat loss with all available strategies (diet and exercise, weight-loss promoting agents and bariatric surgery). Eighty-nine studies, all full papers, were analyzed to evaluate visceral and subcutaneous fat changes, measured through ultrasound, computerized tomography, magnetic resonance imaging and expressed as thickness, weight, area and volume. Studies were included in a meta-analysis (random-effects model). Intervention effect (absolute and percent changes of visceral and subcutaneous fat) was expressed as standardized mean differences, with 95% confidence intervals. Publication bias was formally assessed. The result was that subcutaneous fat was greater than visceral fat when measured as area, volume and weight, not as thickness; decrease of subcutaneous fat was greater than visceral fat when measured as area, volume and weight, not as thickness; percent decrease of visceral fat was always greater than percent decrease of subcutaneous fat, with no differences between different strategies. No intervention preferentially targets visceral fat. Basal visceral fat depots are smaller than basal subcutaneous fat depots. Visceral fat loss is linked to subcutaneous fat loss. With all strategies, percent decrease of visceral fat prevails on subcutaneous fat loss.

  6. Brain tumor locating in 3D MR volume using symmetry

    NASA Astrophysics Data System (ADS)

    Dvorak, Pavel; Bartusek, Karel

    2014-03-01

    This work deals with the automatic determination of a brain tumor location in 3D magnetic resonance volumes. The aim of this work is not the precise segmentation of the tumor and its parts but only the detection of its location. This work is the first step in the tumor segmentation process, an important topic in neuro-image processing. The algorithm expects 3D magnetic resonance volumes of brain containing a tumor. The detection is based on locating the area that breaks the left-right symmetry of the brain. This is done by multi-resolution comparing of corresponding regions in left and right hemisphere. The output of the computation is the probabilistic map of the tumor location. The created algorithm was tested on 80 volumes from publicly available BRATS databases containing 3D brain volumes afflicted by a brain tumor. These pathological structures had various sizes and shapes and were located in various parts of the brain. The locating performance of the algorithm was 85% for T1-weighted volumes, 91% for T1-weighted contrast enhanced volumes, 96% for FLAIR and T2-wieghted volumes and 95% for their combinations.

  7. Application of SOFC for electric vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, K.; Mizusaki, J.; Sasaki, H.

    1995-12-31

    Changing from gasoline powered vehicles to electric vehicles (EVs) will provide positive environmental effects. A present disadvantage of EVs with secondary battery systems is a short driving range. This can be improved by the application of a hybrid system of SOFCs and batteries. For that system, both tubular and planer types of SOFCs having 10kW power are designed which can be used for passenger cars with naphtha as fuel operated at 880--850 C . The tubular type has 106 liters in volume and 100kg in weight, and were smaller and lighter than the planer type. Subjects to be investigated onmore » SOFCs for EVs are described.« less

  8. Regenerative fuel cell energy storage system for a low earth orbit space station

    NASA Technical Reports Server (NTRS)

    Martin, R. E.; Garow, J.; Michaels, K. B.

    1988-01-01

    A study was conducted to define characteristics of a Regenerative Fuel Cell System (RFCS) for low earth orbit Space Station missions. The RFCS's were defined and characterized based on both an alkaline electrolyte fuel cell integrated with an alkaline electrolyte water electrolyzer and an alkaline electrolyte fuel cell integrated with an acid solid polymer electrolyte (SPE) water electrolyzer. The study defined the operating characteristics of the systems including system weight, volume, and efficiency. A maintenance philosophy was defined and the implications of system reliability requirements and modularization were determined. Finally, an Engineering Model System was defined and a program to develop and demonstrate the EMS and pacing technology items that should be developed in parallel with the EMS were identified. The specific weight of an optimized RFCS operating at 140 F was defined as a function of system efficiency for a range of module sizes. An EMS operating at a nominal temperature of 180 F and capable of delivery of 10 kW at an overall efficiency of 55.4 percent is described. A program to develop the EMS is described including a technology development effort for pacing technology items.

  9. 40 CFR 60.54a - Standard for municipal waste combustor acid gases.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989 and on or... weight or volume) or 30 parts per million by volume, corrected to 7 percent oxygen (dry basis), whichever... by volume, corrected to 7 percent oxygen (dry basis), whichever is less stringent. ...

  10. 40 CFR 60.463 - Performance test and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator shall use the following procedures for determining monthly volume-weighted average emissions of... Method 24 or an equivalent or alternative method. The owner or operator shall determine the volume of... facilities, the owner or operator shall estimate the volume of coating used at each affected facility by...

  11. 40 CFR 60.313 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determining monthly volume-weighted average emissions of VOC's in kilograms per liter of coating solids... shall determine the volume of coating and the mass of VOC-solvent used for thinning purposes from... facility or serves both affected and existing facilities, the owner or operator shall estimate the volume...

  12. The TMI regenerable solid oxide fuel cell

    NASA Technical Reports Server (NTRS)

    Cable, Thomas L.

    1995-01-01

    Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. These systems generally consist of photovoltaic solar arrays which operate during sunlight cycles to provide system power and regenerate fuel (hydrogen) via water electrolysis; during dark cycles, hydrogen is converted by the fuel cell into system. The currently preferred configuration uses two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Fuel cell/electrolyzer system simplicity, reliability, and power-to-weight and power-to-volume ratios could be greatly improved if both power production (fuel cell) and power storage (electrolysis) functions can be integrated into a single unit. The Technology Management, Inc. (TMI), solid oxide fuel cell-based system offers the opportunity to both integrate fuel cell and electrolyzer functions into one unit and potentially simplify system requirements. Based an the TMI solid oxide fuel cell (SOPC) technology, the TMI integrated fuel cell/electrolyzer utilizes innovative gas storage and operational concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H2O electrode (SOFC anode/electrolyzer cathode) materials for solid oxide, regenerative fuel cells. Improved H2/H2O electrode materials showed improved cell performance in both fuel cell and electrolysis modes in reversible cell tests. ln reversible fuel cell/electrolyzer mode, regenerative fuel cell efficiencies (ratio of power out (fuel cell mode) to power in (electrolyzer model)) improved from 50 percent (using conventional electrode materials) to over 80 percent. The new materials will allow the TMI SOFC system to operate as both the electrolyzer and fuel cell in a single unit. Preliminary system designs have also been developed which indicate the technical feasibility of using the TMI SOFC technology for space applications with high energy storage efficiencies and high specific energy. Development of small space systems would also have potential dual-use, terrestrial applications.

  13. The TMI regenerable solid oxide fuel cell

    NASA Astrophysics Data System (ADS)

    Cable, Thomas L.

    1995-04-01

    Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. These systems generally consist of photovoltaic solar arrays which operate during sunlight cycles to provide system power and regenerate fuel (hydrogen) via water electrolysis; during dark cycles, hydrogen is converted by the fuel cell into system. The currently preferred configuration uses two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Fuel cell/electrolyzer system simplicity, reliability, and power-to-weight and power-to-volume ratios could be greatly improved if both power production (fuel cell) and power storage (electrolysis) functions can be integrated into a single unit. The Technology Management, Inc. (TMI), solid oxide fuel cell-based system offers the opportunity to both integrate fuel cell and electrolyzer functions into one unit and potentially simplify system requirements. Based an the TMI solid oxide fuel cell (SOPC) technology, the TMI integrated fuel cell/electrolyzer utilizes innovative gas storage and operational concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H2O electrode (SOFC anode/electrolyzer cathode) materials for solid oxide, regenerative fuel cells. Improved H2/H2O electrode materials showed improved cell performance in both fuel cell and electrolysis modes in reversible cell tests. ln reversible fuel cell/electrolyzer mode, regenerative fuel cell efficiencies (ratio of power out (fuel cell mode) to power in (electrolyzer model)) improved from 50 percent (using conventional electrode materials) to over 80 percent. The new materials will allow the TMI SOFC system to operate as both the electrolyzer and fuel cell in a single unit. Preliminary system designs have also been developed which indicate the technical feasibility of using the TMI SOFC technology for space applications with high energy storage efficiencies and high specific energy. Development of small space systems would also have potential dual-use, terrestrial applications.

  14. A portable single-sided magnet system for remote NMR measurements of pulmonary function.

    PubMed

    Dabaghyan, Mikayel; Muradyan, Iga; Hrovat, Alan; Butler, James; Frederick, Eric; Zhou, Feng; Kyriazis, Angelos; Hardin, Charles; Patz, Samuel; Hrovat, Mirko

    2014-12-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). Copyright © 2014 John Wiley & Sons, Ltd.

  15. A portable single-sided magnet system for remote NMR measurements of pulmonary function

    PubMed Central

    Mikayel, Dabaghyan; Iga, Muradyan; James, Butler; Eric, Frederick; Feng, Zhou; Angelos, Kyriazis; Charles, Hardin; Samuel, Patz; Mirko, Hrovat

    2014-01-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). PMID:24953556

  16. Use of Fentanyl in Adolescents with Clinically Severe Obesity Undergoing Bariatric Surgery - a Pilot Study

    PubMed Central

    Vaughns, Janelle D.; Ziesenitz, Victoria C.; Williams, Elaine F.; Mushtaq, Alvina; Bachmann, Ricarda; Skopp, Gisela; Weiss, Johanna; Mikus, Gerd; van den Anker, Johannes N.

    2018-01-01

    Background The number of obese pediatric patients requiring anesthesia is rapidly increasing. Although fentanyl is a commonly used narcotic during surgery, there is no pharmacokinetic (PK) data available for optimal dosing of fentanyl in adolescents with clinically severe obesity. Materials and Methods An IRB-approved exploratory pilot study was conducted in 6 adolescents aged 14 to 19 years undergoing bariatric surgery. Mean total body weight (TBW) and mean BMI were 137.4 ± 14.3 kg, and 49.6 ± 6.4 kg/m2 (99.5th BMI percentile), respectively. Fentanyl was dosed intravenously for intraoperative analgesia based on ideal body weight per standard of care. PK blood samples were drawn over a 24 hour post-dose period. Fentanyl PK parameters were calculated by non-compartmental analysis. Results Mean fentanyl AUC0–∞ was 1.5 ± 0.5 h*ng/mL. Systemic clearance of fentanyl was 1522 ± 310 mL/min and 11.2 ± 2.6 mL/min*kg TBW. Volume of distribution was 635 ± 282 L and 4.7 ± 2.1 L/kg TBW. While absolute clearance was increased, absolute volume of distribution was comparable to previously established adult values. Conclusions These results suggest that fentanyl clearance is enhanced in adolescents with clinically severe obesity while volume of distribution is comparable to previously published studies. PMID:28238111

  17. Introduction of a theoretical splashing degree to assess the performance of low-viscosity oils in filling of capsules.

    PubMed

    Niederquell, Andreas; Kuentz, Martin

    2011-03-01

    These days an alternative to soft capsules is liquid-filled hard capsules. Their filling technology was investigated earlier with highly viscous formulations, while hardly any academic research focused on low-viscosity systems. Accordingly, this work addressed the filling of such oils that are splashing during the dosing process. It was aimed to first study capsule filling, using middle-chain triglycerides as reference oil, in order to then evaluate the concept of a new theoretical splashing degree for different oils. A laboratory-scale filling machine was used that included capsule sealing. Thus, the liquid encapsulation by microspray technology was employed to seal the dosage form. As a result of the study with reference oil, the filling volume and the temperature were found to be significant for the rate of leaking capsules. The filling volume was also important for weight variability of the capsules. However, most critical for this variability was the diameter of the filling nozzle. We proposed a power law for the coefficient of weight variability as a function of the nozzle diameter and the obtained exponent agreed with the proposed theory. Subsequently, a comparison of different oils revealed that the relative splashing degree shared a correlation with the coefficient of the capsule weight variability (Pearson product moment correlation of r=0.990). The novel theoretical concept was therefore found to be predictive for weight variability of the filled capsules. Finally, guidance was provided for the process development of liquid-filled capsules using low-viscosity oils. © 2011 American Association of Pharmaceutical Scientists

  18. Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting.

    PubMed

    Birgani, Mohammadjavad Tahmasebi; Fatahiasl, Jafar; Hosseini, Seyed Mohammad; Bagheri, Ali; Behrooz, Mohammad Ali; Zabiehzadeh, Mansour; Meskani, Reza; Gomari, Maryam Talaei

    2015-01-01

    Utilization of high energy photons (>10 MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6 MV photons and then these calculations were repeated ten times with incorporating 18 MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV (Dmax) and the volume of CTV which covered with 95% Isodose line (VCTV, 95%IDL) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18 MV photons was defined as the intersection point of Dmax and VCTV, 95%IDL graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18 MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.

  19. Development of a Universal Waste Management System

    NASA Technical Reports Server (NTRS)

    Stapleton, Thomas J.; Baccus, Shelley; Broyan, James L., Jr.

    2013-01-01

    NASA is working with a number of commercial companies to develop the next low Earth orbit spacecraft. The hardware volume and weight constraints are similar to or greater than those of the Apollo era. This, coupled with the equally demanding cost challenge of the proposed commercial vehicles, causes much of the Environmental Control and Life Support System (ECLSS) designs to be reconsidered. The Waste Collection System (WCS) is within this group of ECLSS hardware. The development to support this new initiative is discussed within. A WCS concept - intended to be common for all the vehicle platforms currently on the drawing board - is being developed. The new concept, referred to as the Universal Waste Management System (UWMS), includes favorable features from previous designs while improving on other areas on previous Space Shuttle and the existing International Space Station (ISS) WCS hardware, as needed. The intent is to build a commode that requires less crew time, improved cleanliness, and a 75% reduction in volume and weight compared to the previous US ISS/Extended Duration Orbitor WCS developed in the 1990s. The UWMS is most similar to the ISS Development Test Objective (DTO) WCS design. It is understood that the most dramatic cost reduction opportunity occurs at the beginning of the design process. To realize this opportunity, the cost of each similar component between the UWMS and the DTO WCS was determined. The comparison outlined were the design changes that would result with the greatest impact. The changes resulted in simplifying the approach or eliminating components completely. This initial UWMS paper will describe the system layout approach and a few key features of major components. Future papers will describe the UWMS functionality, test results, and components as they are developed.

  20. Non-functional Avionics Requirements

    NASA Astrophysics Data System (ADS)

    Paulitsch, Michael; Ruess, Harald; Sorea, Maria

    Embedded systems in aerospace become more and more integrated in order to reduce weight, volume/size, and power of hardware for more fuel-effi ciency. Such integration tendencies change architectural approaches of system ar chi tec tures, which subsequently change non-functional requirements for plat forms. This paper provides some insight into state-of-the-practice of non-func tional requirements for developing ultra-critical embedded systems in the aero space industry, including recent changes and trends. In particular, formal requi re ment capture and formal analysis of non-functional requirements of avionic systems - including hard-real time, fault-tolerance, reliability, and per for mance - are exemplified by means of recent developments in SAL and HiLiTE.

  1. A design study of a reaction control system for a V/STOL fighter/attack aircraft

    NASA Technical Reports Server (NTRS)

    Beard, B. B.; Foley, W. H.

    1983-01-01

    Attention is given to a short takeoff vertical landing (STOVL) aircraft reaction control system (RCS) design study. The STOVL fighter/attack aircraft employs an existing turbofan engine, and its hover requirement places a premium on weight reduction, which eliminates prospective nonairbreathing RCSs. A simple engine compressor bleed RCS degrades overall performance to an unacceptable degree, and the supersonic requirement precludes the large volume alternatives of thermal or ejector thrust augmentation systems as well as the ducting of engine exhaust gases and the use of a dedicated turbojet. The only system which addressed performance criteria without requiring major engine modifications was a dedicated load compressor driven by an auxilliary power unit.

  2. Association Between Infrapatellar Fat Pad Volume and Knee Structural Changes in Patients with Knee Osteoarthritis.

    PubMed

    Cai, Jingyu; Xu, Jianhua; Wang, Kang; Zheng, Shuang; He, Fan; Huan, Shuting; Xu, Shengqing; Zhang, Hui; Laslett, Laura; Ding, Changhai

    2015-10-01

    The function of the infrapatellar fat pad (IPFP) in knee osteoarthritis (OA) remains uncertain. This study aimed to examine cross-sectional associations between IPFP volume and knee structures in patients with knee OA. The study included 174 patients with clinical knee OA (mean age, 55.5 yrs). Fat-suppressed 3-D T1-weighted spoiled gradient recall magnetic resonance imaging (MRI) was used to measure the IPFP and cartilage volume. T2-weighted fast spin echo MRI was used to assess cartilage defects and bone marrow lesions (BML). Radiographic knee osteophytes and joint space narrowing (JSN) were assessed using the Osteoarthritis Research Society International atlas. After adjustment for potential confounders, greater IPFP volume was associated with greater tibial and patellar cartilage volume (all p < 0.05), and fewer cartilage defects at all sites (OR 0.88-0.91, all p < 0.05). IPFP volume was associated with presence of BML at lateral tibial and medial femoral sites (OR 0.88-0.91, all p < 0.05) and osteophytes at lateral tibiofemoral compartment (OR 0.88, p < 0.05). IPFP volume was not significantly associated with JSN. Greater IPFP volume was associated with greater knee cartilage volume and fewer structural abnormalities, suggesting a protective role of IPFP size in knee OA.

  3. Continuous measurement of drying rate of crystalline and amorphous systems during freeze-drying using an in situ microbalance technique.

    PubMed

    Roth, C; Winter, G; Lee, G

    2001-09-01

    The use of a novel microbalance (Christ) technique to monitor continuously the weight loss of a vial standing on a shelf of a freeze-dryer has been investigated. The drying rates of the following aqueous solutions were measured during the primary drying phase of a complete freeze-drying cycle: sucrose (75 mg/mL, 2.5-mL fill volume), sucrose and phenylalanine (1:0.2 by weight, 75 mg/mL, 2.5-mL fill volume), and mannitol (75mg/mL, 2.5-mL fill volume). The microbalance yields the cumulative water loss, m(cu) in grams, and the momentary drying rate, Deltam(cu)/Deltat in mg/10 min, of the frozen cake. The momentary drying rate curves were especially useful for examining how Deltam(cu)/Deltat changes with time during primary drying. Initially, Deltam(cu)/Deltat rises to a sharp maximum and then decreases in a fashion depending on shelf temperature, chamber pressure, and the nature of the substance being dried. Different drying behavior was observed for the sucrose and sucrose/phenylalanine systems, which was attributed to the presence of crystalline phenylalanine in the amorphous sucrose. At low shelf-temperature (-24 degrees C) the crystalline mannitol showed lower Deltam(cu)/Deltat than with either sucrose or sucrose/phenylalanine. The balance could also detect differences in Deltam(cu)/Deltat when using different freezing protocols. "Slow" and "moderate" freezing protocols gave similar drying behavior, but "rapid" freezing in liquid nitrogen produced greatly altered drying rate and internal cake morphology. The balance also could be used to detect the endpoint of primary drying. Different endpoint criteria and their influence on final dried cake properties were examined. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association

  4. [18F]DPA-714 PET imaging shows immunomodulatory effect of intravenous administration of bone marrow stromal cells after transient focal ischemia.

    PubMed

    Tan, Chengbo; Zhao, Songji; Higashikawa, Kei; Wang, Zifeng; Kawabori, Masahito; Abumiya, Takeo; Nakayama, Naoki; Kazumata, Ken; Ukon, Naoyuki; Yasui, Hironobu; Tamaki, Nagara; Kuge, Yuji; Shichinohe, Hideo; Houkin, Kiyohiro

    2018-05-02

    The potential application of bone marrow stromal cell (BMSC) therapy in stroke has been anticipated due to its immunomodulatory effects. Recently, positron emission tomography (PET) with [ 18 F]DPA-714, a translocator protein (TSPO) ligand, has become available for use as a neural inflammatory indicator. We aimed to evaluate the effects of BMSC administration after transient middle cerebral artery occlusion (MCAO) using [ 18 F]DPA-714 PET. The BMSCs or vehicle were administered intravenously to rat MCAO models at 3 h after the insult. Neurological deficits, body weight, infarct volume, and histology were analyzed. [ 18 F]DPA-714 PET was performed 3 and 10 days after MCAO. Rats had severe neurological deficits and body weight loss after MCAO. Cell administration ameliorated these effects as well as the infarct volume. Although weight loss occurred in the spleen and thymus, cell administration suppressed it. In both vehicle and BMSC groups, [ 18 F]DPA-714 PET showed a high standardized uptake value (SUV) around the ischemic area 3 days after MCAO. Although SUV was increased further 10 days after MCAO in both groups, the increase was inhibited in the BMSC group, significantly. Histological analysis showed that an inflammatory reaction occurred in the lymphoid organs and brain after MCAO, which was suppressed in the BMSC group. The present results suggest that BMSC therapy could be effective in ischemic stroke due to modulation of systemic inflammatory responses. The [ 18 F]DPA-714 PET/CT system can accurately demonstrate brain inflammation and evaluate the BMSC therapeutic effect in an imaging context. It has great potential for clinical application.

  5. Quantitative evaluation of apical extrusion of debris and irrigants using four rotary instrumentation systems: an in vitro study.

    PubMed

    Nagaveni, S Aspalli; Balakoti, K Reddy; Smita, Karan; Ratnakar, P; Satish, S V; Aravind, T

    2013-11-01

    The apical extrusion of infected debris may have the potential to disrupt the balance between microbial aggression and host defense, resulting in incidents of acute inflammation. During preparation, irrigants and debris, such as bacteria, dentin filings and necrotic tissue may be extruded into the periradicular region leading to periapical inflammation and postoperative flare ups. Using an instrumentation technique that minimizes apical extrusion would be beneficial to both the practitioner and patient. The purpose of the study was to evaluate the weight of debris and volume of irrigant extruded apically from extracted teeth in vitro after endodontic instrumentation using four different rotary root canal instrumentation systems. Four groups of each 20 extracted mandibular premolars were instrumented using one of the four systems: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland)), Hero-shaper (MicroMega, Besancon, France), RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and K3 (SybronEndo, West Collins, CA). Debris and irrigant extruded from the apical foramen during instrumentation were collected in preweighed test tubes. Volume of irrigant extruded was noted. The containers were stored in incubator at 70° for two days to evaporate the moisture. Weight of dry debris was noted. Data was analyzed using Kruskall-Wallis and Mann-Whitney U test at a significance of 0.001. The results indicated that all of the instrumentation systems tested caused measurable apical extrusion of debris and irrigants. Higher extrusion was observed with Protaper system which was statistically significant with Hero-Shaper, RaCe and K3 systems. There were no statistical differences between Hero-shaper, K3 and RaCe systems (p < 0.05). All instrumentation techniques apically extruded debris and irrigant. However, Hero-shaper, K3 and RaCe systems produced less extruded debris and irrigant than the Protaper system.

  6. Volume-weighted measure for eternal inflation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winitzki, Sergei

    2008-08-15

    I propose a new volume-weighted probability measure for cosmological 'multiverse' scenarios involving eternal inflation. The 'reheating-volume (RV) cutoff' calculates the distribution of observable quantities on a portion of the reheating hypersurface that is conditioned to be finite. The RV measure is gauge-invariant, does not suffer from the 'youngness paradox', and is independent of initial conditions at the beginning of inflation. In slow-roll inflationary models with a scalar inflaton, the RV-regulated probability distributions can be obtained by solving nonlinear diffusion equations. I discuss possible applications of the new measure to 'landscape' scenarios with bubble nucleation. As an illustration, I compute themore » predictions of the RV measure in a simple toy landscape.« less

  7. 21 CFR 177.2415 - Poly(aryletherketone) resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., and have a minimum weight-average molecular weight of 12,000, as determined by gel permeation...: Distilled water, 50 percent (by volume) ethanol in distilled water, 3 percent acetic acid in distilled water...

  8. Incubator weaning in preterm infants and associated practice variation.

    PubMed

    Schneiderman, R; Kirkby, S; Turenne, W; Greenspan, J

    2009-08-01

    To evaluate the relationship of weight of preterm infants when first placed into an open crib with days to full oral feedings, growth velocity and length of stay (LOS), and to identify unwarranted variation in incubator weaning after adjusting for severity indices. A retrospective study using the ParadigmHealth neonatal database from 2003 to 2006 reviewed incubator weaning to an open crib in appropriate-for-gestational-age (AGA) infants from 22 to weeks gestation. Primary outcome measurements included days to full oral (PO) feeding, weight gain from open crib to discharge and length of stay. Models were severity adjusted. To understand hospital practice variation, we also used a regression model to estimate the weight at open crib for the top 10 volume hospitals. In all 2908 infants met the inclusion criteria for the study. Their mean weight at open crib was 1850 g. On average every additional 100 g an infant weighed at the open crib was associated with increased time to full PO feeding by 0.8 days, decreased weight gained per day by 1 gram and increased LOS by 0.9 days. For the top 10 volume hospitals, severity variables alone accounted for 9% of the variation in weight at open crib, whereas the hospital in which the baby was treated accounted for an additional 19% of the variation. Even after controlling for severity, significant practice variation exists in weaning to an open crib, leading to potential delays in achieving full-volume oral feeds, decreased growth velocity and prolonged LOS.

  9. Granuloma Weight and the α1-acute Phase Protein Response in Rats Injected with Turpentine

    PubMed Central

    Darcy, D. A.

    1970-01-01

    Rats of 6 different age (and weight) groups were injected with turpentine subcutaneously in a single depot at 4 different doses per kg. body weight. In each age/weight group the weight of the turpentine granuloma produced at 48 hr was proportional to log turpentine dose. The 48 hr response of the α1-AP (acute phase) globulin was also proportional to log turpentine dose and was proportional to the granuloma weight. When rats of different age/weight groups were compared it was found that granuloma weight increased logarithmically with body weight for a given turpentine dose per kg. body weight. More remarkably, granuloma weight increased logarithmically with body weight for a constant volume of turpentine injected per rat, thus 0·2 ml. of turpentine gave an 0·65 g. granuloma in 60 g. (4-week old) rats and a 5 g. granuloma in 371 g. (40-week old) rats. The possibility of an age influence on this phenomenon was not excluded by these experiments. The α1-AP globulin response also increased logarithmically with body weight for a given turpentine dose per kg. body weight. For a constant volume of turpentine per rat, the response increased logarithmically with body weight and directly with granuloma weight. It was concluded that this acute phase protein response is closely correlated with the size of the lesion. There was some evidence, however, that the age of the rat may make a contribution to the response. The histology of the granulomata is described. PMID:4190826

  10. Reference Gauging System for a Small-Scale Liquid Hydrogen Tank

    NASA Technical Reports Server (NTRS)

    VanDresar, Neil T.; Siegwarth, James D.

    2003-01-01

    A system to accurately weigh the fluid contents of a small-scale liquid hydrogen test tank has been experimentally verified. It is intended for use as a reference or benchmark system when testing lowgravity liquid quantity gauging concepts in the terrestrial environment. The reference gauging system has shown a repeatable measurement accuracy of better than 0.5 percent of the full tank liquid weight. With further refinement, the system accuracy can be improved to within 0.10 percent of full scale. This report describes the weighing system design, calibration, and operational results. Suggestions are given for further refinement of the system. An example is given to illustrate additional sources of uncertainty when mass measurements are converted to volume equivalents. Specifications of the companion test tank and its multi-layer insulation system are provided.

  11. On the origin of Triton

    NASA Astrophysics Data System (ADS)

    Celebonovic, V.

    1986-01-01

    The origin of Triton, based on the theory of materials under high pressure by Savic and Kasanin (1962, 1965), is described. The mean molecular weight (A) and the volume of one gram mole of Triton's material (V) are evaluated using its values of mass and radius; it is calculated that A = 67 + or - 2 and V = 3 + or - 2. These values are compared with Celebonovic's (1983) model of Neptune; it is observed that the mean molecular weight of Triton is ten times larger than Neptune's. The cause of this large variation in chemical composition is investigated. It is hypothesized that Triton and Neptune formed in different regions of the solar system, and that Triton was ejected from its primordial orbit and was later captured by Neptune.

  12. Metalclad Airship Hull Study. Volume 1 and Volume 2

    DTIC Science & Technology

    1976-12-01

    37.5% weight saving of the hull skin with a maximim pressure of 8.75 in. of water column and maximum-minimum pressure ratio still at comfortable 3.5. The...overall height of 118.98 in.to no more than 100.Oin. with considerable weight saving . Instead of the geometrical height of main frames equal to (.108...changed slightly to obtain uniform spacing. This has negligible effect on the result, but saves a considerable analysis timie. For the purpose of this

  13. Rapid Weight Loss and the Body Fluid Balance and Hemoglobin Mass of Elite Amateur Boxers

    PubMed Central

    Reljic, Dejan; Hässler, Eike; Jost, Joachim; Friedmann-Bette, Birgit

    2013-01-01

    Context Dehydration is assumed to be a major adverse effect associated with rapid loss of body mass for competing in a lower weight class in combat sports. However, the effects of such weight cutting on body fluid balance in a real-life setting are unknown. Objective To examine the effects of 5% or greater loss of body mass within a few days before competition on body water, blood volume, and plasma volume in elite amateur boxers. Design Case-control study. Setting Sports medicine laboratory. Patients or Other Participants Seventeen male boxers (age = 19.2 ± 2.9 years, height = 175.1 ± 7.0 cm, mass = 65.6 ± 9.2 kg) were assigned to the weight-loss group (WLG; n = 10) or the control group (CON; n = 7). Intervention(s) The WLG reduced body mass by restricting fluid and food and inducing excessive sweat loss by adhering to individual methods. The CON participated in their usual precompetition training. Main Outcome Measure(s) During an ordinary training period (t-1), 2 days before competition (t-2), and 1 week after competition (t-3), we performed bioelectrical impedance measurements; calculated total body water, intracellular water, and extracellular water; and estimated total hemoglobin mass (tHbmass), blood volume, and plasma volume by the CO-rebreathing method. Results In the WLG, the loss of body mass (5.6% ± 1.7%) led to decreases in total body water (6.0% ± 0.9%), extracellular water (12.4% ± 7.6%), tHbmass (5.3% ± 3.8%), blood volume (7.6% ± 2.1%; P < .001), and plasma volume (8.6% ± 3.9%). The intracellular water did not change (P > .05). At t-3, total body water, extracellular water, and plasma volume had returned to near baseline values, but tHbmass and blood volume still were less than baseline values (P < .05). In CON, we found no changes (P > .05). Conclusions In a real-life setting, the loss of approximately 6% body mass within 5 days induced hypohydration, which became evident by the decreases in body water and plasma volume. The reduction in tHbmass was a surprising observation that needs further investigation. PMID:23672332

  14. Proceedings of the Power Sources Conference (36th) Held in Cherry Hill, New Jersey on June 6-9, 1994

    DTIC Science & Technology

    1994-06-09

    bi- polar design. Activation: Entrapped gas bubbles are diffiult to remove. Thorough wetting requires pulling vacuum several times. Initial Charging...accomplished by pulling an exdernal vacuum which evacuates air from each cell through the sNTEvCEI.L-fill I vent tubes. After release of vacuum and...density = 1.75 amnps/in2 System Weight =86 lbs (9.7 WI-l1b) System Volume =1071 in3 (.78 W~fn 3) 7SI I I I I I 70 C~~URREN PRGRM GOALI 60 CCLE IFEEPI is

  15. Vertical farming increases lettuce yield per unit area compared to conventional horizontal hydroponics.

    PubMed

    Touliatos, Dionysios; Dodd, Ian C; McAinsh, Martin

    2016-08-01

    Vertical farming systems (VFS) have been proposed as an engineering solution to increase productivity per unit area of cultivated land by extending crop production into the vertical dimension. To test whether this approach presents a viable alternative to horizontal crop production systems, a VFS (where plants were grown in upright cylindrical columns) was compared against a conventional horizontal hydroponic system (HHS) using lettuce ( Lactuca sativa L . cv. "Little Gem") as a model crop. Both systems had similar root zone volume and planting density. Half-strength Hoagland's solution was applied to plants grown in perlite in an indoor controlled environment room, with metal halide lamps providing artificial lighting. Light distribution (photosynthetic photon flux density, PPFD) and yield (shoot fresh weight) within each system were assessed. Although PPFD and shoot fresh weight decreased significantly in the VFS from top to base, the VFS produced more crop per unit of growing floor area when compared with the HHS. Our results clearly demonstrate that VFS presents an attractive alternative to horizontal hydroponic growth systems and suggest that further increases in yield could be achieved by incorporating artificial lighting in the VFS.

  16. Design and implementation of a cost-accounting system in hospital pharmacy.

    PubMed

    Gouveia, W A; Anderson, E R; Decker, E L; Backer, K

    1988-03-01

    The design and implementation of a cost-accounting system in a hospital pharmacy department is described. Pharmacy resource use (labor, drugs, supplies, and overhead), or pharmacy's intermediate products, was clearly defined in terms of dosage forms (10 groupings representing variable labor and supplies) and drug products (more than 100 categories that incorporate cost and volume of use for 3000 line items). Costs were defined as variable or nonvariable (fixed), based on whether they were related to a specific medication order. Labor was divided into variable and fixed components. Time standards were developed using time and motion studies. Variable labor hours were determined as follows: specified hours (the volume of each dosage form multiplied by the standard time for each dosage form); nonspecified hours (time not directly associated with production); hours worked (specified plus nonspecified hours); and hours paid (hours worked plus sick leave and vacation). A standard cost for each drug product was based on the weighted average of volume and cost of the individual line items. The total drug budget was constructed by multiplying the standard cost for each drug product times the projected volume for each drug product. The pharmacy budget was developed by calculating the number and mix of pharmacy products used in association with the projected number and type of cases for the fiscal year. The monthly pharmacy budget reports were assembled with data from the payroll, billing, and cost-accounting systems.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Improved scaling laws for stage inert mass space Propulsion systems. Volume 3: Propulsion synthesis program users and programmers manual

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The analytical models developed for the Space Propulsion Automated Synthesis Modeling (SPASM) program are presented. Weight scaling laws developed during this study are incorporated into the program's scaling data bank. A detail listing, logic diagram and input/output formats are supplied for the SPASM program. Two test examples for one to four-stage vehicles performing different types of missions are shown to demonstrate the program's capability and versatility.

  18. The 1985 Army Experience Survey: Tabular Descriptions of First-Term Separatees. Volume 2

    DTIC Science & Technology

    1986-01-01

    through survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The coding schemes developed to...270-271 048 R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY ...... .................. ... 272-273 049 E137 # TERMS OF ACTIVE ENLISTMENT...STATISTIC VALUE D.F. PROB. CHISQUARE APPROX. 7.830 5 0.1658 e. U 272 R136 -- REGION OF RIESIDENCE WHEN YOU JOINED ARMY RECODED - WHAT STATE WERE YOU LIVING

  19. The 1985 Army Experience Survey: Tabular Descriptions of First-Term Separatees. Volume 1

    DTIC Science & Technology

    1986-01-01

    Assistance. Survey data were processed through survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The...268-269 047A R135 AGE OF OLDEST CHILD. ..................... .. ..... 270-271 048 R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY...100.0 STATISTIC VALUE D.F. PROD. CHISQUARE APPROX. 65.725 10 0.0000 272 R136 -- REGION OF RESIDENCE WHEN YOU JOINED ARMY RECODED - WHAT STATE WERE

  20. The 1985 Army Experience Survey: Tabular Descriptions of Mid-Career Separatees. Volume 2

    DTIC Science & Technology

    1986-01-01

    Survey data were processed through survey receipt control and sample management systems . Data were also keyed, edited, coded, and weighted. The coding...270-271 048 R136 REGION OF RESIDENCE WHEN YOU JOINED ARMY ................. . 272-273 049 E137 # TERMS OF ACTIVE ENLISTMENT...STATISTIC VALUE D.F. PROB. CHISQUARE APPROX. 4.449 5 0.4868 I 272 R136 -- REGION OF RESIDENCE WHEN YOU JOINED ARMY RECODED - WHAT STATE WERE YOU LIVING IN

Top