Sample records for t-lock automated compensation

  1. Design and performance of an astigmatism-compensated self-mode-locked ring-cavity Ti:sapphire laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Y.; Dai, J.; Wang, Q.

    1996-12-31

    Based on the nonlinear ABCD matrix and the renormalized q-parameter for Gaussian-beam propagation, self-focusing in conjunction with a spatial gain profile for self-mode locking in a ring-cavity Ti:sapphire laser is analyzed. In the experiment, an astigmatism-compensated self-mode-locked ring-cavity Ti:sapphire laser is demonstrated, and self-mode-locked operation is achieved in both bidirection and unidirection with pulse durations as short as 36 fs and 32 fs, respectively. The experimental observations are in good agreement with theoretical predictions.

  2. Phase-locked-loop interferometry applied to aspheric testing with a computer-stored compensator.

    PubMed

    Servin, M; Malacara, D; Rodriguez-Vera, R

    1994-05-01

    A recently developed technique for continuous-phase determination of interferograms with a digital phase-locked loop (PLL) is applied to the null testing of aspheres. Although this PLL demodulating scheme is also a synchronous or direct interferometric technique, the separate unwrapping process is not explicitly required. The unwrapping and the phase-detection processes are achieved simultaneously within the PLL. The proposed method uses a computer-generated holographic compensator. The holographic compensator does not need to be printed out by any means; it is calculated and used from the computer. This computer-stored compensator is used as the reference signal to phase demodulate a sample interferogram obtained from the asphere being tested. Consequently the demodulated phase contains information about the wave-front departures from the ideal computer-stored aspheric interferogram. Wave-front differences of ~ 1 λ are handled easily by the proposed PLL scheme. The maximum recorded frequency in the template's interferogram as well as in the sampled interferogram are assumed to be below the Nyquist frequency.

  3. Self-locking telescoping manipulator arm

    NASA Technical Reports Server (NTRS)

    Nesmith, M. F. (Inventor)

    1985-01-01

    A telescoping manipulator arm and pivotable finger assembly are disclosed. The telescoping arm assembly includes a generally T-shaped arm having three outwardly extending fingers guided on grooved roller guides to compensate for environmental variations. The pivotable finger assembly includes four pivoting fingers. Arcuate teeth are formed on the ends of the fingers. A rack having teeth on four sides meshes with each one of the fingers. One surface of the rack includes teeth along its entire surface which mesh with teeth of one of the fingers. The teeth at the remote end of the rack engage teeth of a gear wheel. The wheel includes a worm which meshes with a worn drive shaft of the drive motor providing a ninety degree self-locking drive for locking the fingers in a desired position. A similar drive provides a self-locking drive for positioning the telescoping arm.

  4. The class characteristic mark of the H&M Mul-T-Lock picking tool in toolmarks examination.

    PubMed

    Volkov, Nikolai; Finkelstein, Nir; Novoselsky, Yehuda; Tsach, Tsadok

    2014-07-01

    Mul-T-Lock is a high security lock cylinder distinguished by the use of a telescoping "pin-in-pin"-tumbler design. Picking the Mul-T-Lock cylinder with a traditional picking tool is highly complicated because it can get stuck between the inner and outer pins. The H&M Mul-T-Lock picking tool was designed to overcome this problem and facilitate the picking of the "pin-in-pin" cylinder. The purpose of this research is to determine whether H&M Mul-T-Lock picking tool leaves class characteristic mark and whether it can be distinguished from traditional picking tools marks and from regular key marks. It also describes and determines the class characteristic mark left on telescopic pins, its origin, recurrence, and its benefit to the toolmarks examiner. When receiving a Mul-T-Lock from a crime scene, a toolmarks examiner can quickly determine whether or not it was picked by an H&M Mul-T-Lock picking tool by noticing the class characteristic mark which this typical tool leaves. © 2014 American Academy of Forensic Sciences.

  5. Direct generation of 128-fs Gaussian pulses from a compensation-free fiber laser using dual mode-locking mechanisms

    NASA Astrophysics Data System (ADS)

    Peng, Junsong; Zhan, Li; Gu, Zhaochang; Qian, Kai; Luo, Shouyu; Shen, Qishun

    2012-03-01

    We have experimentally demonstrated the direct generation of 128-fs pulses in an all-anomalous-dispersion all-fiber mode-locked laser. The laser is free of dispersion compensation in the cavity based on standard single mode fiber (SMF). The time-bandwidth product is 0.536. The laser is achieved by using two mode-lockers, one is nonlinear polarization rotation (NPR), and the other is nonlinear amplifying loop mirror. The coexistence of dual mode-locking mechanisms can decrease the cavity length to 12-m, and also results in producing high-quality pulses with a Gaussian shape both on the pulse profile and spectrum, but without Kelly sidebands.

  6. Studying the VCSEL to VCSEL injection locking for enhanced chromatic dispersion compensation

    NASA Astrophysics Data System (ADS)

    Li, Linfu

    2010-11-01

    In order to supply a theoretical guide for digital chaotic telecommunication, the technique of Optical injection locking (OIL) of semiconductor lasers on the chaotic communication have been investigated based on the theoretical models used to describe the dynamics of solitary VCSEL subjected to the external optical injection and signal transmission in fiber. The numerical simulation results show that, the frequency chirp and time-resolved chirp are reduced in magnitude, using a VCSEL laser as master and another VCSEL as slave, it leads to a no-penalty transmission over 50 km of uncompensated in SSMF at 10Gb/s, and it could be higher rate and more remote if there were appropriate compensation.

  7. Enhancement of the transversal magnetic optic Kerr effect: Lock-in vs. hysteresis method.

    PubMed

    Hayek, Jorge Nicolás; Herreño-Fierro, César A; Patiño, Edgar J

    2016-10-01

    The lock-in amplifier is often used to study the enhancement of the magneto-optical Kerr effect (MOKE) in the presence of plasmon resonances. In the present work we show that it is possible to investigate such effect replacing the lock-in amplifier by a compensator, filter, and differential amplifier. This allows us to extract the full hysteresis loop in and out of the resonance without the need of a lock-in amplifier. Our results demonstrate these two setups are equivalent to study the enhancement of the transversal MOKE (T-MOKE) in magnetoplasmonic systems.

  8. Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements.

    PubMed

    Olivier, Michel; Gagnon, Marc-Daniel; Habel, Joé

    2016-02-28

    When a laser is mode-locked, it emits a train of ultra-short pulses at a repetition rate determined by the laser cavity length. This article outlines a new and inexpensive procedure to force mode locking in a pre-adjusted nonlinear polarization rotation fiber laser. This procedure is based on the detection of a sudden change in the output polarization state when mode locking occurs. This change is used to command the alignment of the intra-cavity polarization controller in order to find mode-locking conditions. More specifically, the value of the first Stokes parameter varies when the angle of the polarization controller is swept and, moreover, it undergoes an abrupt variation when the laser enters the mode-locked state. Monitoring this abrupt variation provides a practical easy-to-detect signal that can be used to command the alignment of the polarization controller and drive the laser towards mode locking. This monitoring is achieved by feeding a small portion of the signal to a polarization analyzer measuring the first Stokes parameter. A sudden change in the read out of this parameter from the analyzer will occur when the laser enters the mode-locked state. At this moment, the required angle of the polarization controller is kept fixed. The alignment is completed. This procedure provides an alternate way to existing automating procedures that use equipment such as an optical spectrum analyzer, an RF spectrum analyzer, a photodiode connected to an electronic pulse-counter or a nonlinear detecting scheme based on two-photon absorption or second harmonic generation. It is suitable for lasers mode locked by nonlinear polarization rotation. It is relatively easy to implement, it requires inexpensive means, especially at a wavelength of 1550 nm, and it lowers the production and operation costs incurred in comparison to the above-mentioned techniques.

  9. Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements

    PubMed Central

    Olivier, Michel; Gagnon, Marc-Daniel; Habel, Joé

    2016-01-01

    When a laser is mode-locked, it emits a train of ultra-short pulses at a repetition rate determined by the laser cavity length. This article outlines a new and inexpensive procedure to force mode locking in a pre-adjusted nonlinear polarization rotation fiber laser. This procedure is based on the detection of a sudden change in the output polarization state when mode locking occurs. This change is used to command the alignment of the intra-cavity polarization controller in order to find mode-locking conditions. More specifically, the value of the first Stokes parameter varies when the angle of the polarization controller is swept and, moreover, it undergoes an abrupt variation when the laser enters the mode-locked state. Monitoring this abrupt variation provides a practical easy-to-detect signal that can be used to command the alignment of the polarization controller and drive the laser towards mode locking. This monitoring is achieved by feeding a small portion of the signal to a polarization analyzer measuring the first Stokes parameter. A sudden change in the read out of this parameter from the analyzer will occur when the laser enters the mode-locked state. At this moment, the required angle of the polarization controller is kept fixed. The alignment is completed. This procedure provides an alternate way to existing automating procedures that use equipment such as an optical spectrum analyzer, an RF spectrum analyzer, a photodiode connected to an electronic pulse-counter or a nonlinear detecting scheme based on two-photon absorption or second harmonic generation. It is suitable for lasers mode locked by nonlinear polarization rotation. It is relatively easy to implement, it requires inexpensive means, especially at a wavelength of 1550 nm, and it lowers the production and operation costs incurred in comparison to the above-mentioned techniques. PMID:26967924

  10. Artifacts correction for T1rho imaging with constant amplitude spin-lock

    NASA Astrophysics Data System (ADS)

    Chen, Weitian

    2017-01-01

    T1rho imaging with constant amplitude spin-lock is prone to artifacts in the presence of B1 RF and B0 field inhomogeneity. Despite significant technological progress, improvements on the robustness of constant amplitude spin-lock are necessary in order to use it for routine clinical practice. This work proposes methods to simultaneously correct for B1 RF and B0 field inhomogeneity in constant amplitude spin-lock. By setting the maximum B1 amplitude of the excitation adiabatic pulses equal to the expected constant amplitude spin-lock frequency, the spins become aligned along the effective field throughout the spin-lock process. This results in T1rho-weighted images free of artifacts, despite the spatial variation of the effective field caused by B1 RF and B0 field inhomogeneity. When the pulse is long, the relaxation effect during the adiabatic half passage may result in a non-negligible error in the mono-exponential relaxation model. A two-acquisition approach is presented to solve this issue. Simulation, phantom, and in-vivo scans demonstrate the proposed methods achieve superior image quality compared to existing methods, and that the two-acquisition method is effective in resolving the relaxation effect during the adiabatic half passage.

  11. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Optimized efficient liver T1ρ mapping using limited spin lock times

    NASA Astrophysics Data System (ADS)

    Yuan, Jing; Zhao, Feng; Griffith, James F.; Chan, Queenie; Wang, Yi-Xiang J.

    2012-03-01

    T1ρ relaxation has recently been found to be sensitive to liver fibrosis and has potential to be used for early detection of liver fibrosis and grading. Liver T1ρ imaging and accurate mapping are challenging because of the long scan time, respiration motion and high specific absorption rate. Reduction and optimization of spin lock times (TSLs) are an efficient way to reduce scan time and radiofrequency energy deposition of T1ρ imaging, but maintain the near-optimal precision of T1ρ mapping. This work analyzes the precision in T1ρ estimation with limited, in particular two, spin lock times, and explores the feasibility of using two specific operator-selected TSLs for efficient and accurate liver T1ρ mapping. Two optimized TSLs were derived by theoretical analysis and numerical simulations first, and tested experimentally by in vivo rat liver T1ρ imaging at 3 T. The simulation showed that the TSLs of 1 and 50 ms gave optimal T1ρ estimation in a range of 10-100 ms. In the experiment, no significant statistical difference was found between the T1ρ maps generated using the optimized two-TSL combination and the maps generated using the six TSLs of [1, 10, 20, 30, 40, 50] ms according to one-way ANOVA analysis (p = 0.1364 for liver and p = 0.8708 for muscle).

  13. AutoLock: a semiautomated system for radiotherapy treatment plan quality control.

    PubMed

    Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G

    2015-05-08

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.

  14. AutoLock: a semiautomated system for radiotherapy treatment plan quality control

    PubMed Central

    Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.

    2015-01-01

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498

  15. Automated hierarchical time gain compensation for in-vivo ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Moshavegh, Ramin; Hemmsen, Martin C.; Martins, Bo; Brandt, Andreas H.; Hansen, Kristoffer L.; Nielsen, Michael B.; Jensen, Jørgen A.

    2015-03-01

    Time gain compensation (TGC) is essential to ensure the optimal image quality of the clinical ultrasound scans. When large fluid collections are present within the scan plane, the attenuation distribution is changed drastically and TGC compensation becomes challenging. This paper presents an automated hierarchical TGC (AHTGC) algorithm that accurately adapts to the large attenuation variation between different types of tissues and structures. The algorithm relies on estimates of tissue attenuation, scattering strength, and noise level to gain a more quantitative understanding of the underlying tissue and the ultrasound signal strength. The proposed algorithm was applied to a set of 44 in vivo abdominal movie sequences each containing 15 frames. Matching pairs of in vivo sequences, unprocessed and processed with the proposed AHTGC were visualized side by side and evaluated by two radiologists in terms of image quality. Wilcoxon signed-rank test was used to evaluate whether radiologists preferred the processed sequences or the unprocessed data. The results indicate that the average visual analogue scale (VAS) is positive ( p-value: 2.34 × 10-13) and estimated to be 1.01 (95% CI: 0.85; 1.16) favoring the processed data with the proposed AHTGC algorithm.

  16. Designing Estimator/Predictor Digital Phase-Locked Loops

    NASA Technical Reports Server (NTRS)

    Statman, J. I.; Hurd, W. J.

    1988-01-01

    Signal delays in equipment compensated automatically. New approach to design of digital phase-locked loop (DPLL) incorporates concepts from estimation theory and involves decomposition of closed-loop transfer function into estimator and predictor. Estimator provides recursive estimates of phase, frequency, and higher order derivatives of phase with respect to time, while predictor compensates for delay, called "transport lag," caused by PLL equipment and by DPLL computations.

  17. Hysteresis in the tearing mode locking/unlocking due to resonant magnetic perturbations in EXTRAP T2R

    NASA Astrophysics Data System (ADS)

    Fridström, R.; Frassinetti, L.; Brunsell, P. R.

    2015-10-01

    The physical mechanisms behind the hysteresis in the tearing mode locking and unlocking to a resonant magnetic perturbation (RMP) are experimentally studied in EXTRAP T2R reversed-field pinch. The experiments show that the electromagnetic and the viscous torque increase with increasing perturbation amplitude until the mode locks to the wall. At the wall-locking, the plasma velocity reduction profile is peaked at the radius where the RMP is resonant. Thereafter, the viscous torque drops due to the relaxation of the velocity in the central plasma. This is the main reason for the hysteresis in the RMP locking and unlocking amplitude. The increased amplitude of the locked tearing mode produces further deepening of the hysteresis. Both experimental results are in qualitative agreement with the model in Fitzpatrick et al (2001 Phys. Plasmas 8 4489)

  18. The tearing mode locking-unlocking mechanism to an external resonant field in EXTRAP T2R

    NASA Astrophysics Data System (ADS)

    Frassinetti, L.; Fridström, R.; Menmuir, S.; Brunsell, P. R.

    2014-10-01

    The tearing mode (TM) locking and unlocking process due to an external resonant magnetic perturbation (RMP) is experimentally studied in EXTRAP T2R. The RMP produces a reduction of the natural TM velocity and ultimately the TM locking if a threshold in the RMP amplitude is exceeded. During the braking process, the TM slows down via a mechanism composed of deceleration and acceleration phases. During the acceleration phases, the TM can reach velocities higher than the natural velocity. Once the TM locking occurs, the RMP must be reduced to a small amplitude to obtain the TM unlocking, showing that the unlocking threshold is significantly smaller than the locking threshold and that the process is characterized by hysteresis. Experimental results are in qualitative agreement with a model that describes the locking-unlocking process via the balance of the electromagnetic torque produced by the RMP that acts to brake the TM and the viscous torque that tends to re-establish the unperturbed velocity.

  19. Mechanism of Elongation Factor-G-mediated Fusidic Acid Resistance and Fitness Compensation in Staphylococcus aureus *

    PubMed Central

    Koripella, Ravi Kiran; Chen, Yang; Peisker, Kristin; Koh, Cha San; Selmer, Maria; Sanyal, Suparna

    2012-01-01

    Antibiotic resistance in bacteria is often associated with fitness loss, which is compensated by secondary mutations. Fusidic acid (FA), an antibiotic used against pathogenic bacteria Staphylococcus aureus, locks elongation factor-G (EF-G) to the ribosome after GTP hydrolysis. To clarify the mechanism of fitness loss and compensation in relation to FA resistance, we have characterized three S. aureus EF-G mutants with fast kinetics and crystal structures. Our results show that a significantly slower tRNA translocation and ribosome recycling, plus increased peptidyl-tRNA drop-off, are the causes for fitness defects of the primary FA-resistant mutant F88L. The double mutant F88L/M16I is three to four times faster than F88L in both reactions and showed no tRNA drop-off, explaining its fitness compensatory phenotype. The M16I mutation alone showed hypersensitivity to FA, higher activity, and somewhat increased affinity to GTP. The crystal structures demonstrate that Phe-88 in switch II is a key residue for FA locking and also for triggering interdomain movements in EF-G essential for its function, explaining functional deficiencies in F88L. The mutation M16I loosens the hydrophobic core in the G domain and affects domain I to domain II contact, resulting in improved activity both in the wild-type and F88L background. Thus, FA-resistant EF-G mutations causing fitness loss and compensation operate by affecting the conformational dynamics of EF-G on the ribosome. PMID:22767604

  20. 33 CFR 165.T09-0166 - Safety Zone, Brandon Road Lock and Dam to Lake Michigan including Des Plaines River, Chicago...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety Zone, Brandon Road Lock... Areas Ninth Coast Guard District § 165.T09-0166 Safety Zone, Brandon Road Lock and Dam to Lake Michigan.... waters of the Des Plaines River located between mile marker 286.0 (Brandon Road Lock and Dam) and mile...

  1. Tilt-tuned etalon locking for tunable laser stabilization.

    PubMed

    Gibson, Bradley M; McCall, Benjamin J

    2015-06-15

    Locking to a fringe of a tilt-tuned etalon provides a simple, inexpensive method for stabilizing tunable lasers. Here, we describe the use of such a system to stabilize an external-cavity quantum cascade laser; the locked laser has an Allan deviation of approximately 1 MHz over a one-second integration period, and has a single-scan tuning range of approximately 0.4  cm(-1). The system is robust, with minimal alignment requirements and automated lock acquisition, and can be easily adapted to different wavelength regions or more stringent stability requirements with minor alterations.

  2. Stuck in a job: being “locked-in” or at risk of becoming locked-in at the workplace and well-being over time

    PubMed Central

    Stengård, Johanna; Bernhard-Oettel, Claudia; Berntson, Erik; Leineweber, Constanze; Aronsson, Gunnar

    2016-01-01

    ABSTRACT In this study, being “locked-in” at the workplace is conceptualized as being in a non-preferred workplace while at the same time perceiving low employability. The aim of the study was to investigate how being locked-in or at risk of becoming locked-in (being in a non-preferred workplace yet currently satisfied, combined with perceiving low employability) relates to well-being (subjective health and depressive symptoms). The hypotheses were tested in a Swedish longitudinal sample (T1 in 2010 and T2 in 2012) of permanent employees (N = 3491). The results showed that stability with regard to locked-in-related status (being non-locked-in, at risk of becoming locked-in, or locked-in at both T1 and T2) was related to significant and stable differences in well-being. The non-locked-in status was associated with better well-being than being at risk of becoming locked-in. Moreover, those at risk of becoming locked-in showed better well-being than those with stable locked-in status. Changes towards non-locked-in were accompanied by significant improvements in well-being, and changes towards locked-in were associated with impairments in well-being. The relationships that were found could not be attributed to differences in demographic variables and occupational preference. The findings indicate that being locked-in is detrimental to well-being. This has implications for preventative interventions. PMID:27226678

  3. 33 CFR 165.T08-0432 - Safety Zone; Waterway Closure, Morgan City-Port Allen Route from Mile Marker 0 to Port Allen Lock.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Morgan City-Port Allen Route from Mile Marker 0 to Port Allen Lock. 165.T08-0432 Section 165.T08-0432... Limited Access Areas Eighth Coast Guard District § 165.T08-0432 Safety Zone; Waterway Closure, Morgan City... Water Way on the Morgan City—Port Allen route from MM 0 to the Port Allen lock. (b) Effective date. This...

  4. Automated T2 relaxometry of the hippocampus for temporal lobe epilepsy.

    PubMed

    Winston, Gavin P; Vos, Sjoerd B; Burdett, Jane L; Cardoso, M Jorge; Ourselin, Sebastien; Duncan, John S

    2017-09-01

    Hippocampal sclerosis (HS), the most common cause of refractory temporal lobe epilepsy, is associated with hippocampal volume loss and increased T2 signal. These can be identified on quantitative imaging with hippocampal volumetry and T2 relaxometry. Although hippocampal segmentation for volumetry has been automated, T2 relaxometry currently involves subjective and time-consuming manual delineation of regions of interest. In this work, we develop and validate an automated technique for hippocampal T2 relaxometry. Fifty patients with unilateral or bilateral HS and 50 healthy controls underwent T 1 -weighted and dual-echo fast recovery fast spin echo scans. Hippocampi were automatically segmented using a multi-atlas-based segmentation algorithm (STEPS) and a template database. Voxelwise T2 maps were determined using a monoexponential fit. The hippocampal segmentations were registered to the T2 maps and eroded to reduce partial volume effect. Voxels with T2 >170 msec excluded to minimize cerebrospinal fluid (CSF) contamination. Manual determination of T2 values was performed twice in each subject. Twenty controls underwent repeat scans to assess interscan reproducibility. Hippocampal T2 values were reliably determined using the automated method. There was a significant ipsilateral increase in T2 values in HS (p < 0.001), and a smaller but significant contralateral increase. The combination of hippocampal volumes and T2 values separated the groups well. There was a strong correlation between automated and manual methods for hippocampal T2 measurement (0.917 left, 0.896 right, both p < 0.001). Interscan reproducibility was superior for automated compared to manual measurements. Automated hippocampal segmentation can be reliably extended to the determination of hippocampal T2 values, and a combination of hippocampal volumes and T2 values can separate subjects with HS from healthy controls. There is good agreement with manual measurements, and the technique is more

  5. Mode locking with a compensated space--time astigmatism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christov, I.P.; Stoev, V.D.; Murnane, M.M.

    1995-10-15

    We present what is to our knowledge the first full spatial plus temporal model of a self-mode-locked titanium-doped sapphire laser. The self-consistent evolution of the pulse toward steady state imposes strong space--time focusing in the crystal, where both the space and time foci are located. This combined focusing significantly improves the discrimination properties of the nonlinear resonator for shorter pulses and reduces the transient stage of pulse formation. Our theoretical results are in very good agreement with experiment. {copyright} {ital 1995} {ital Optical} {ital Society} {ital of} {ital America}.

  6. Note: Digital laser frequency auto-locking for inter-satellite laser ranging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Yingxin; Yeh, Hsien-Chi, E-mail: yexianji@mail.hust.edu.cn; Li, Hongyin

    2016-05-15

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  7. 33 CFR 165.T08-0434 - Safety Zone; Mile Marker 98.5 West of Harvey Lock Gulf Intracoastal Waterway to Mile Marker 108.5...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety Zone; Mile Marker 98.5 West of Harvey Lock Gulf Intracoastal Waterway to Mile Marker 108.5 West of Harvey Lock Gulf... § 165.T08-0434 Safety Zone; Mile Marker 98.5 West of Harvey Lock Gulf Intracoastal Waterway to Mile...

  8. Deployable reflector antenna performance optimization using automated surface correction and array-feed compensation

    NASA Technical Reports Server (NTRS)

    Schroeder, Lyle C.; Bailey, M. C.; Mitchell, John L.

    1992-01-01

    Methods for increasing the electromagnetic (EM) performance of reflectors with rough surfaces were tested and evaluated. First, one quadrant of the 15-meter hoop-column antenna was retrofitted with computer-driven and controlled motors to allow automated adjustment of the reflector surface. The surface errors, measured with metric photogrammetry, were used in a previously verified computer code to calculate control motor adjustments. With this system, a rough antenna surface (rms of approximately 0.180 inch) was corrected in two iterations to approximately the structural surface smoothness limit of 0.060 inch rms. The antenna pattern and gain improved significantly as a result of these surface adjustments. The EM performance was evaluated with a computer program for distorted reflector antennas which had been previously verified with experimental data. Next, the effects of the surface distortions were compensated for in computer simulations by superimposing excitation from an array feed to maximize antenna performance relative to an undistorted reflector. Results showed that a 61-element array could produce EM performance improvements equal to surface adjustments. When both mechanical surface adjustment and feed compensation techniques were applied, the equivalent operating frequency increased from approximately 6 to 18 GHz.

  9. 41. LOCK AND DAM NO. 26 (REPLACEMENT). LOCK LOCK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. LOCK AND DAM NO. 26 (REPLACEMENT). LOCK -- LOCK GATES -- LIFT GATE, GATE LEAVES -- GENERAL ASSEMBLY. M-L 26(R) 21/28 - Upper Mississippi River 9-Foot Channel Project, Lock & Dam 26R, Alton, Madison County, IL

  10. Biomechanical comparison of locked versus non-locked symphyseal plating of unstable pelvic ring injuries.

    PubMed

    Godinsky, R J; Vrabec, G A; Guseila, L M; Filipkowski, D E; Elias, J J

    2018-04-01

    Locked symphyseal plates are utilized to provide higher levels of construct stiffness than non-locked plates. The current biomechanical study was performed to compare stiffness at the pubic symphysis between locked and non-locked plating systems. Synthetic models were utilized to represent injury to the pelvis and symphyseal plating combined with a sacro-iliac screw. Seven models were evaluated with plates and locking screws, and seven were evaluated with non-locking screws. Single limb stance was simulated, with all models loaded for 1000 cycles with 350 N applied at the sacrum. Two pairs of markers crossing the symphysis were tracked with a video-based tracking system. A coordinate system was developed to quantify motion between the pairs in three directions: medial-lateral gap, anterior-posterior shear translation, and superior-inferior shear translation. Significant differences between the plating systems were identified with t tests (p < 0.05). Anterior-posterior shear translation varied significantly between the two plating systems. From cycles 100 to 1000, average shear translation for the non-locked and locked systems was ~0.7 and 0.3 mm, respectively, at the markers closest to the plate and 2.2 and 1.4 mm, respectively, at the markers further from the plate. Motion in the other two directions did not differ significantly between locked and non-locked models. Locked symphyseal plating systems can provide better stability than non-locked systems for anterior-posterior shear translation. More stability could potentially reduce the risk of failure of the plate or screws.

  11. Injection locked coupled opto-electronic oscillator for optical frequency comb generation

    NASA Astrophysics Data System (ADS)

    Williams, Charles; Mandridis, Dimitrios; Davila-Rodriguez, Josue; Delfyett, Peter J.

    2011-06-01

    A CW injection locked Coupled Opto-Electronic Oscillator (COEO) is presented with a 10.24 GHz spaced optical frequency comb output as well as a low noise RF output. A modified Pound-Drever-Hall scheme is employed to ensure long-term stability of the injection lock, feeding back into the cavity length to compensate for cavity resonance drifts relative to the injection seed frequency. Error signal comparison to an actively mode-locked injection locked laser is presented. High optical signal-to-noise ratio of ~35 dB is demonstrated with >20 comblines of useable bandwidth. The optical linewidth, in agreement with injection locking theory, reduces to that of the injection seed frequency, <5 kHz. Low amplitude and absolute phase noise are presented from the optical output of the laser system. The integrated pulse-to-pulse energy fluctuation was found to be reduced by up to a factor of two due to optical injection. Additional decreases were shown for varying injection powers.

  12. Analysis and experimental demonstration of conformal adaptive phase-locked fiber array for laser communications and beam projection applications

    NASA Astrophysics Data System (ADS)

    Liu, Ling

    The primary goal of this research is the analysis, development, and experimental demonstration of an adaptive phase-locked fiber array system for free-space optical communications and laser beam projection applications. To our knowledge, the developed adaptive phase-locked system composed of three fiber collimators (subapertures) with tip-tilt wavefront phase control at each subaperture represents the first reported fiber array system that implements both phase-locking control and adaptive wavefront tip-tilt control capabilities. This research has also resulted in the following innovations: (a) The first experimental demonstration of a phase-locked fiber array with tip-tilt wave-front aberration compensation at each fiber collimator; (b) Development and demonstration of the fastest currently reported stochastic parallel gradient descent (SPGD) system capable of operation at 180,000 iterations per second; (c) The first experimental demonstration of a laser communication link based on a phase-locked fiber array; (d) The first successful experimental demonstration of turbulence and jitter-induced phase distortion compensation in a phase-locked fiber array optical system; (e) The first demonstration of laser beam projection onto an extended target with a randomly rough surface using a conformal adaptive fiber array system. Fiber array optical systems, the subject of this study, can overcome some of the draw-backs of conventional monolithic large-aperture transmitter/receiver optical systems that are usually heavy, bulky, and expensive. The primary experimental challenges in the development of the adaptive phased-locked fiber-array included precise (<5 microrad) alignment of the fiber collimators and development of fast (100kHz-class) phase-locking and wavefront tip-tilt control systems. The precise alignment of the fiber collimator array is achieved through a specially developed initial coarse alignment tool based on high precision piezoelectric picomotors and a

  13. A first approach for digital representation and automated classification of toolmarks on locking cylinders using confocal laser microscopy

    NASA Astrophysics Data System (ADS)

    Clausing, Eric; Kraetzer, Christian; Dittmann, Jana; Vielhauer, Claus

    2012-10-01

    An important part of criminalistic forensics is the analysis of toolmarks. Such toolmarks often consist of plenty of single striations, scratches and dents which can allow for conclusions in regards to the sequence of events or used tools. To receive qualified results with an automated analysis and contactless acquisition of such toolmarks, a detailed digital representation of these and their orientation as well as placing to each other is required. For marks of firearms and tools the desired result of an analysis is a conclusion whether or not a mark has been generated by a tool under suspicion. For toolmark analysis on locking cylinders, the aim is not an identification of the used tool but rather an identification of the opening method. The challenge of such an identification is that a one-to-one comparison of two images is not sufficient - although two marked objects look completely different in regards to the specific location and shape of found marks they still can represent a sample for the identical opening method. This paper provides the first approach for modelling toolmarks on lock pins and takes into consideration the different requirements necessary to generate a detailed and interpretable digital representation of these traces. These requirements are 'detail', i.e. adequate features which allow for a suitable representation and interpretation of single marks, 'meta detail', i.e. adequate representation of the context and connection between all marks and 'distinctiveness', i.e. the possibility to reliably distinguish different sample types by the according model. The model is evaluated with a set of 15 physical samples (resulting in 675 digital scans) of lock pins from cylinders opened with different opening methods, contactlessly scanned with a confocal laser microscope. The presented results suggest a high suitability for the aspired purpose of opening method determination.

  14. Note: Low phase noise programmable phase-locked loop with high temperature stability.

    PubMed

    Michálek, Vojtěch; Procházka, Ivan

    2017-03-01

    The design and construction of low jitter programmable phase-locked loop with low temperature coefficient of phase are presented. It has been designed for demanding high precision timing applications, especially as a clock source for event timer with subpicosecond precision. The phase-locked loop itself has a jitter of few hundreds of femtoseconds. It produces square wave with programmable output frequency from 100 MHz to 500 MHz and programmable amplitude of 0.25 V to 1.2 V peak-to-peak, which is locked to 5 MHz or 10 MHz reference frequency common for disciplined oscillators and highly stable clocks such as hydrogen maser. Moreover, it comprises an on-board temperature compensated crystal oscillator for stand-alone usage. The device provides temperature coefficient of the phase lock of 0.9 ps/K near room temperature.

  15. Algorithms to automate gap-dependent integral tuning for the 2.8-meter long horizontal field undulator with a dynamic force compensation mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Joseph Z., E-mail: x@anl.gov; Vasserman, Isaac; Strelnikov, Nikita

    2016-07-27

    A 2.8-meter long horizontal field prototype undulator with a dynamic force compensation mechanism has been developed and tested at the Advanced Photon Source (APS) at Argonne National Laboratory (Argonne). The magnetic tuning of the undulator integrals has been automated and accomplished by applying magnetic shims. A detailed description of the algorithms and performance is reported.

  16. Automated aberration compensation in high numerical aperture systems for arbitrary laser modes (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hering, Julian; Waller, Erik H.; von Freymann, Georg

    2017-02-01

    Since a large number of optical systems and devices are based on differently shaped focal intensity distributions (point-spread-functions, PSF), the PSF's quality is crucial for the application's performance. E.g., optical tweezers, optical potentials for trapping of ultracold atoms as well as stimulated-emission-depletion (STED) based microscopy and lithography rely on precisely controlled intensity distributions. However, especially in high numerical aperture (NA) systems, such complex laser modes are easily distorted by aberrations leading to performance losses. Although different approaches addressing phase retrieval algorithms have been recently presented[1-3], fast and automated aberration compensation for a broad variety of complex shaped PSFs in high NA systems is still missing. Here, we report on a Gerchberg-Saxton[4] based algorithm (GSA) for automated aberration correction of arbitrary PSFs, especially for high NA systems. Deviations between the desired target intensity distribution and the three-dimensionally (3D) scanned experimental focal intensity distribution are used to calculate a correction phase pattern. The target phase distribution plus the correction pattern are displayed on a phase-only spatial-light-modulator (SLM). Focused by a high NA objective, experimental 3D scans of several intensity distributions allow for characterization of the algorithms performance: aberrations are reliably identified and compensated within less than 10 iterations. References 1. B. M. Hanser, M. G. L. Gustafsson, D. A. Agard, and J. W. Sedat, "Phase-retrieved pupil functions in wide-field fluorescence microscopy," J. of Microscopy 216(1), 32-48 (2004). 2. A. Jesacher, A. Schwaighofer, S. Frhapter, C. Maurer, S. Bernet, and M. Ritsch-Marte, "Wavefront correction of spatial light modulators using an optical vortex image," Opt. Express 15(9), 5801-5808 (2007). 3. A. Jesacher and M. J. Booth, "Parallel direct laser writing in three dimensions with spatially dependent

  17. The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

    PubMed

    Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J

    2011-08-01

    Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.

  18. Reaction Times to Consecutive Automation Failures: A Function of Working Memory and Sustained Attention.

    PubMed

    Jipp, Meike

    2016-12-01

    This study explored whether working memory and sustained attention influence cognitive lock-up, which is a delay in the response to consecutive automation failures. Previous research has demonstrated that the information that automation provides about failures and the time pressure that is associated with a task influence cognitive lock-up. Previous research has also demonstrated considerable variability in cognitive lock-up between participants. This is why individual differences might influence cognitive lock-up. The present study tested whether working memory-including flexibility in executive functioning-and sustained attention might be crucial in this regard. Eighty-five participants were asked to monitor automated aircraft functions. The experimental manipulation consisted of whether or not an initial automation failure was followed by a consecutive failure. Reaction times to the failures were recorded. Participants' working-memory and sustained-attention abilities were assessed with standardized tests. As expected, participants' reactions to consecutive failures were slower than their reactions to initial failures. In addition, working-memory and sustained-attention abilities enhanced the speed with which participants reacted to failures, more so with regard to consecutive than to initial failures. The findings highlight that operators with better working memory and sustained attention have small advantages when initial failures occur, but their advantages increase across consecutive failures. The results stress the need to consider personnel selection strategies to mitigate cognitive lock-up in general and training procedures to enhance the performance of low ability operators. © 2016, Human Factors and Ergonomics Society.

  19. How We Hear What Is Hardly There: Mechanisms Underlying Compensation for /t/-Reduction in Speech Comprehension

    ERIC Educational Resources Information Center

    Mitterer, Holger; Yoneyama, Kiyoko; Ernestus, Mirjam

    2008-01-01

    In four experiments, we investigated how listeners compensate for reduced /t/ in Dutch. Mitterer and Ernestus [Mitterer, H., & Ernestus, M. (2006). "Listeners recover /t/s that speakers lenite: evidence from /t/-lenition in Dutch." "Journal of Phonetics," 34, 73-103] showed that listeners are biased to perceive a /t/ more easily after /s/ than…

  20. The RABiT: A Rapid Automated Biodosimetry Tool For Radiological Triage. II. Technological Developments

    PubMed Central

    Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.

    2011-01-01

    Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703

  1. Passive athermalization of multimode interference devices for wavelength-locking applications.

    PubMed

    Ruiz-Perez, Victor I; May-Arrioja, Daniel A; Guzman-Sepulveda, Jose R

    2017-03-06

    In this paper we demonstrate the passive, material-based athermalization of all-fiber architectures by cascading multimode interference (MMI) devices. In-line thermal compensation is achieved by including a liquid-core multimode section of variable length that allows ensuring temperature-independent operation while preserving the inherent filter-like spectral response of the MMI devices. The design of the temperature compensation unit is straightforward and its fabrication is simple. The applicability of our approach is experimentally verified by fabricating a wavelength-locked MMI laser with sensitivity of only -0.1 pm/°C, which is at least one order of magnitude lower than that achieved with other fiber optics devices.

  2. Design of a lock-amplifier circuit

    NASA Astrophysics Data System (ADS)

    Liu, H.; Huang, W. J.; Song, X.; Zhang, W. Y.; Sa, L. B.

    2017-01-01

    The lock-in amplifier is recovered by phase sensitive detection technique for the weak signal submerged in the noise background. This design is based on the TI ultra low power LM358, INA129, OPA227, OP07 and other chips as the core design and production of the lock-in amplifier. Signal generator by 10m ohms /1K ohm resistance points pressure network 10 mu V 1mV adjustable sine wave signal s (T). The concomitant interference signal together through the AC amplifier and band-pass filter signal x (T), on the other hand reference signal R (T) driven by square wave phase shift etc. steps to get the signal R (T), two signals and by phase sensitive detector are a DC full wave, again through its low pass filter and a DC amplifier to be measured signal more accurate detection, the final circuit through the AD conversion and the use of single-chip will display the output.

  3. Timely event-related synchronization fading and phase de-locking and their defects in migraine.

    PubMed

    Yum, Myung-Kul; Moon, Jin-Hwa; Kang, Joong Koo; Kwon, Oh-Young; Park, Ki-Jong; Shon, Young-Min; Lee, Il Keun; Jung, Ki-Young

    2014-07-01

    To investigate the characteristics of event-related synchronization (ERS) fading and phase de-locking of alpha waves during passive auditory stimulation (PAS) in the migraine patients. The subjects were 16 adult women with migraine and 16 normal controls. Electroencephalographic (EEG) data obtained during PAS with standard (SS) and deviant stimuli (DS) were used. Alpha ERS fading, the phase locking index (PLI) and de-locking index (DLI) were evaluated from the 10 Hz complex Morlet wavelet components at 100 ms (t100) and 300 ms (t300) after PAS. At t100, significant ERS was found with SS and DS in the migraineurs and controls (P=0.000). At t300 in the controls, ERS faded to zero for DS while in the migraineurs there was no fading for DS. In both groups the PLI for SS and DS was significantly reduced, i.e. de-locked, at t300 compared to t100 (P=0.000). In the migraineurs, the DLI for DS was significantly lower than in the controls (P=0.003). The alpha ERS fading and phase de-locking are defective in migraineurs during passive auditory cognitive processing. The defects in timely alpha ERS fading and in de-locking may play a role in the different attention processing in migraine patients. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Generation of sub-100-fs pulses from a CW mode-locked chromium-doped forsterite laser

    NASA Technical Reports Server (NTRS)

    Seas, A.; Petricevic, V.; Alfano, R. R.

    1992-01-01

    Generation of femtosecond pulses from a continuous-wave mode-locked chromium-doped forsterite laser is reported. The forsterite laser was actively mode locked by using an acoustooptic modulator operating at 78 MHz with two Brewster high-dispersion glass prisms for intracavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(00) mode with 85 mW of continuous power (with 1 percent output coupler), tunable over 1230-1280 nm. The shortest pulses measured had a 60-fs pulse width.

  5. Distal tibia fractures: locked or non-locked plating?

    PubMed Central

    Khalsa, Amrit S; Toossi, Nader; Tabb, Loni P; Amin, Nirav H; Donohue, Kenneth W; Cerynik, Douglas L

    2014-01-01

    Background and purpose Although plating is considered to be the treatment of choice in distal tibia fractures, controversies abound regarding the type of plating for optimal fixation. We conducted a systematic review to evaluate and compare the outcomes of locked plating and non-locked plating in treatment of distal tibia fractures. Patients and methods A systematic review was conducted using PubMed to identify articles on the outcomes of plating in distal tibia fractures that were published up to June 2012. We included English language articles involving a minimum of 10 adult cases with acute fractures treated using single-plate, minimally invasive techniques. Study-level binomial regression on the pooled data was conducted to determine the effect of locking status on different outcomes, adjusted for age, sex, and other independent variables. Results 27 studies met the inclusion criteria and were included in the final analysis of 764 cases (499 locking, 265 non-locking). Based on descriptive analysis only, delayed union was reported in 6% of cases with locked plating and in 4% of cases with non-locked plating. Non-union was reported in 2% of cases with locked plating and 3% of cases with non-locked plating. Comparing locked and non-locked plating, the odds ratio (OR) for reoperation was 0.13 (95% CI: 0.03–0.57) and for malalignment it was 0.10 (95% CI: 0.02–0.42). Both values were statistically significant. Interpretation This study showed that locked plating reduces the odds of reoperation and malalignment after treatment for acute distal tibia fracture. Future studies should accurately assess causality and the clinical and economic impact of these findings. PMID:24758325

  6. Automated T2-mapping of the Menisci From Magnetic Resonance Images in Patients with Acute Knee Injury.

    PubMed

    Paproki, Anthony; Engstrom, Craig; Strudwick, Mark; Wilson, Katharine J; Surowiec, Rachel K; Ho, Charles; Crozier, Stuart; Fripp, Jurgen

    2017-10-01

    This study aimed to evaluate the accuracy of an automated method for segmentation and T2 mapping of the medial meniscus (MM) and lateral meniscus (LM) in clinical magnetic resonance images from patients with acute knee injury. Eighty patients scheduled for surgery of an anterior cruciate ligament or meniscal injury underwent magnetic resonance imaging of the knee (multiplanar two-dimensional [2D] turbo spin echo [TSE] or three-dimensional [3D]-TSE examinations, T2 mapping). Each meniscus was automatically segmented from the 2D-TSE (composite volume) or 3D-TSE images, auto-partitioned into anterior, mid, and posterior regions, and co-registered onto the T2 maps. The Dice similarity index (spatial overlap) was calculated between automated and manual segmentations of 2D-TSE (15 patients), 3D-TSE (16 patients), and corresponding T2 maps (31 patients). Pearson and intraclass correlation coefficients (ICC) were calculated between automated and manual T2 values. T2 values were compared (Wilcoxon rank sum tests) between torn and non-torn menisci for the subset of patients with both manual and automated segmentations to compare statistical outcomes of both methods. The Dice similarity index values for the 2D-TSE, 3D-TSE, and T2 map volumes, respectively, were 76.4%, 84.3%, and 75.2% for the MM and 76.4%, 85.1%, and 76.1% for the LM. There were strong correlations between automated and manual T2 values (r MM  = 0.95, ICC MM  = 0.94; r LM  = 0.97, ICC LM  = 0.97). For both the manual and the automated methods, T2 values were significantly higher in torn than in non-torn MM for the full meniscus and its subregions (P < .05). Non-torn LM had higher T2 values than non-torn MM (P < .05). The present automated method offers a promising alternative to manual T2 mapping analyses of the menisci and a considerable advance for integration into clinical workflows. Copyright © 2017 The Association of University Radiologists. All rights reserved.

  7. 49 CFR 236.337 - Locking faces of mechanical locking; fit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...

  8. 49 CFR 236.337 - Locking faces of mechanical locking; fit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...

  9. 49 CFR 236.337 - Locking faces of mechanical locking; fit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...

  10. 49 CFR 236.337 - Locking faces of mechanical locking; fit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...

  11. Dispersion engineering of mode-locked fibre lasers

    NASA Astrophysics Data System (ADS)

    Woodward, R. I.

    2018-03-01

    Mode-locked fibre lasers are important sources of ultrashort pulses, where stable pulse generation is achieved through a balance of periodic amplitude and phase evolutions. A range of distinct cavity pulse dynamics have been revealed, arising from the interplay between dispersion and nonlinearity in addition to dissipative processes such as filtering. This has led to the discovery of numerous novel operating regimes, offering significantly improved laser performance. In this Topical Review, we summarise the main steady-state pulse dynamics reported to date through cavity dispersion engineering, including average solitons, dispersion-managed solitons, dissipative solitons, giant-chirped pulses and similaritons. Characteristic features and the stabilisation mechanism of each regime are described, supported by numerical modelling, in addition to the typical performance and limitations. Opportunities for further pulse energy scaling are discussed, in addition to considering other recent advances including automated self-tuning cavities and fluoride-fibre-based mid-infrared mode-locked lasers.

  12. Complete pulse characterization of quantum dot mode-locked lasers suitable for optical communication up to 160 Gbit/s.

    PubMed

    Schmeckebier, H; Fiol, G; Meuer, C; Arsenijević, D; Bimberg, D

    2010-02-15

    A complete characterization of pulse shape and phase of a 1.3 microm, monolithic-two-section, quantum-dot mode-locked laser (QD-MLL) at a repetition rate of 40 GHz is presented, based on frequency resolved optical gating. We show that the pulse broadening of the QD-MLL is caused by linear chirp for all values of current and voltage investigated here. The chirp increases with the current at the gain section, whereas larger bias at the absorber section leads to less chirp and therefore to shorter pulses. Pulse broadening is observed at very high bias, likely due to the quantum confined stark effect. Passive- and hybrid-QD-MLL pulses are directly compared. Improved pulse intensity profiles are found for hybrid mode locking. Via linear chirp compensation pulse widths down to 700 fs can be achieved independent of current and bias, resulting in a significantly increased overall mode-locking range of 101 MHz. The suitability of QD-MLL chirp compensated pulse combs for optical communication up to 160 Gbit/s using optical-time-division multiplexing are demonstrated by eye diagrams and autocorrelation measurements.

  13. Symbol lock detection implemented with nonoverlapping integration intervals

    NASA Technical Reports Server (NTRS)

    Shihabi, Mazen M. (Inventor); Hinedi, Sami M. (Inventor); Shah, Biren N. (Inventor)

    1995-01-01

    A symbol lock detector is introduced for an incoming coherent digital communication signal which utilizes a subcarrier modulated with binary symbol data, d(sub k), and known symbol interval T by integrating binary values of the signal over nonoverlapping first and second intervals selected to be T/2, delaying the first integral an interval T/2, and either summing or multiplying the second integral with the first one that preceded it to form a value X(sub k). That value is then averaged over a number M of symbol intervals to produce a static value Y. A symbol lock decision can then be made when the static value Y exceeds a threshold level delta.

  14. Automated Identification of MHD Mode Bifurcation and Locking in Tokamaks

    NASA Astrophysics Data System (ADS)

    Riquezes, J. D.; Sabbagh, S. A.; Park, Y. S.; Bell, R. E.; Morton, L. A.

    2017-10-01

    Disruption avoidance is critical in reactor-scale tokamaks such as ITER to maintain steady plasma operation and avoid damage to device components. A key physical event chain that leads to disruptions is the appearance of rotating MHD modes, their slowing by resonant field drag mechanisms, and their locking. An algorithm has been developed that automatically detects bifurcation of the mode toroidal rotation frequency due to loss of torque balance under resonant braking, and mode locking for a set of shots using spectral decomposition. The present research examines data from NSTX, NSTX-U and KSTAR plasmas which differ significantly in aspect ratio (ranging from A = 1.3 - 3.5). The research aims to examine and compare the effectiveness of different algorithms for toroidal mode number discrimination, such as phase matching and singular value decomposition approaches, and to examine potential differences related to machine aspect ratio (e.g. mode eigenfunction shape variation). Simple theoretical models will be compared to the dynamics found. Main goals are to detect or potentially forecast the event chain early during a discharge. This would serve as a cue to engage active mode control or a controlled plasma shutdown. Supported by US DOE Contracts DE-SC0016614 and DE-AC02-09CH11466.

  15. Broadband 19F TOCSY using BURBOP-based spin lock

    NASA Astrophysics Data System (ADS)

    Marchione, Alexander A.; Diaz, Elizabeth L.

    2018-01-01

    A train of BURBOP universal rotation pulses has been used to generate a spin lock sufficient to observe TOCSY correlations over a 46 kHz 19F spectral window (i.e. 122 ppm on a 9.4 T spectrometer). This spin lock requires lower RF field (γB1 = 15 kHz), and was employed over a wider spectral window, than previously reported DIPSI-2 spin locks. The BURBOP-based spin lock was effected for 80-160 ms periods with a 2% duty cycle without evidence of harm to the RF coil of the probehead. Spectral separation and full set of correlations were obtained for a mixture of perfluorocarbons.

  16. An active locking mechanism for assembling 3D micro structures

    NASA Astrophysics Data System (ADS)

    Zhang, Ping; Mayyas, Mohammad; Lee, Woo Ho; Popa, Dan; Shiakolas, Panos; Stephanou, Harry; Chiao, J. C.

    2007-01-01

    Microassembly is an enabling technology to build 3D microsystems consisting of microparts made of different materials and processes. Multiple microparts can be connected together to construct complicated in-plane and out-of-plane microsystems by using compliant mechanical structures such as micro hinges and snap fasteners. This paper presents design, fabrication, and assembly of an active locking mechanism that provides mechanical and electrical interconnections between mating microparts. The active locking mechanism is composed of thermally actuated Chevron beams and sockets. Assembly by means of an active locking mechanism offers more flexibility in designing microgrippers as it reduces or minimizes mating force, which is one of the main reasons causing fractures in a microgripper during microassembly operation. Microgrippers, microparts, and active locking mechanisms were fabricated on a silicon substrate using the deep reactive ion etching (DRIE) processes with 100-um thick silicon on insulator (SOI) wafers. A precision robotic assembly platform with a dual microscope vision system was used to automate the manipulation and assembly processes of microparts. The assembly sequence includes (1) tether breaking and picking up of a micropart by using an electrothermally actuated microgripper, (2) opening of a socket area for zero-force insertion, (3) a series of translation and rotation of a mating micropart to align it onto the socket, (4) insertion of a micropart into the socket, and (5) deactivation and releasing of locking fingers. As a result, the micropart was held vertically to the substrate and locked by the compliance of Chevron beams. Microparts were successfully assembled using the active locking mechanism and the measured normal angle was 89.2°. This active locking mechanism provides mechanical and electrical interconnections, and it can potentially be used to implement a reconfigurable microrobot that requires complex assembly of multiple links and

  17. Locking hinge

    NASA Technical Reports Server (NTRS)

    Wesselski, Clarence J. (Inventor)

    1988-01-01

    The space station configuration currently studied utilizes structures which require struts to be hinged in the middle in the stowed mode and locked into place in the deployed mode. Since there are hundreds of hinges involved, it is necessary that they have simple, positive locking features with a minimum of joint looseness or slack. This invention comprises two similar housings hinged together with a spring loaded locking member which assists in making as well as breaking the lock. This invention comprises a bracket hinge and bracket members with a spring biased and movable locking member. The locking or latch member has ear parts received in locking openings where wedging surfaces on the ear parts cooperate with complimentary surfaces on the bracket members for bringing the bracket members into a tight end-to-end alignment when the bracket members are in an extended position. When the locking member is moved to an unlocking position, pivoting of the hinge about a pivot pin automatically places the locking member to retain the locking member in an unlocked position. In pivoting the hinge from an extended position to a folded position, longitudinal spring members are placed under tension over annular rollers so that the spring tension in a folded position assists in return of the hinge from a folded to an extended position. Novelty lies in the creation of a locking hinge which allows compact storage and easy assembly of structural members having a minimal number of parts.

  18. First experimental demonstration of self-synchronous phase locking of an optical array

    NASA Astrophysics Data System (ADS)

    Shay, T. M.; Benham, Vincent; Baker, J. T.; Ward, Benjamin; Sanchez, Anthony D.; Culpepper, Mark A.; Pilkington, D.; Spring, Justin; Nelson, Douglas J.; Lu, Chunte A.

    2006-12-01

    A novel, highly accurate, all electronic technique for phase locking arrays of optical fibers is demonstrated. We report the first demonstration of the only electronic phase locking technique that doesn’t require a reference beam. The measured phase error is λ/20. Excellent phase locking has been demonstrated for fiber amplifier arrays.

  19. 49 CFR 236.337 - Locking faces of mechanical locking; fit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking faces of mechanical locking; fit. 236.337 Section 236.337 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit...

  20. Automated manufacturing of chimeric antigen receptor T cells for adoptive immunotherapy using CliniMACS prodigy.

    PubMed

    Mock, Ulrike; Nickolay, Lauren; Philip, Brian; Cheung, Gordon Weng-Kit; Zhan, Hong; Johnston, Ian C D; Kaiser, Andrew D; Peggs, Karl; Pule, Martin; Thrasher, Adrian J; Qasim, Waseem

    2016-08-01

    Novel cell therapies derived from human T lymphocytes are exhibiting enormous potential in early-phase clinical trials in patients with hematologic malignancies. Ex vivo modification of T cells is currently limited to a small number of centers with the required infrastructure and expertise. The process requires isolation, activation, transduction, expansion and cryopreservation steps. To simplify procedures and widen applicability for clinical therapies, automation of these procedures is being developed. The CliniMACS Prodigy (Miltenyi Biotec) has recently been adapted for lentiviral transduction of T cells and here we analyse the feasibility of a clinically compliant T-cell engineering process for the manufacture of T cells encoding chimeric antigen receptors (CAR) for CD19 (CAR19), a widely targeted antigen in B-cell malignancies. Using a closed, single-use tubing set we processed mononuclear cells from fresh or frozen leukapheresis harvests collected from healthy volunteer donors. Cells were phenotyped and subjected to automated processing and activation using TransAct, a polymeric nanomatrix activation reagent incorporating CD3/CD28-specific antibodies. Cells were then transduced and expanded in the CentriCult-Unit of the tubing set, under stabilized culture conditions with automated feeding and media exchange. The process was continuously monitored to determine kinetics of expansion, transduction efficiency and phenotype of the engineered cells in comparison with small-scale transductions run in parallel. We found that transduction efficiencies, phenotype and function of CAR19 T cells were comparable with existing procedures and overall T-cell yields sufficient for anticipated therapeutic dosing. The automation of closed-system T-cell engineering should improve dissemination of emerging immunotherapies and greatly widen applicability. Copyright © 2016. Published by Elsevier Inc.

  1. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  2. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  3. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  4. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  5. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  6. 12. LOCK GATES AT THE SWAMP LOCKS, SEPARATING THE UPPER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. LOCK GATES AT THE SWAMP LOCKS, SEPARATING THE UPPER AND LOWER LOCK CHAMBERS, SHOWING PADDLE VALVES, LOOKING WEST: 1976 - Pawtucket Canal, Swamp Locks, Pawtucket & Merrimack Canals, Lowell, Middlesex County, MA

  7. Crystallization and X-ray diffraction analysis of an 'all-locked' nucleic acid duplex derived from a tRNA(Ser) microhelix.

    PubMed

    Behling, Katja; Eichert, André; Fürste, Jens P; Betzel, Christian; Erdmann, Volker A; Förster, Charlotte

    2009-08-01

    Modified nucleic acids are of great interest with respect to their nuclease resistance and enhanced thermostability. In therapeutical and diagnostic applications, such molecules can substitute for labile natural nucleic acids that are targeted against particular diseases or applied in gene therapy. The so-called 'locked nucleic acids' contain modified sugar moieties such as 2'-O,4'-C-methylene-bridged beta-D-ribofuranose and are known to be very stable nucleic acid derivatives. The structure of locked nucleic acids in single or multiple LNA-substituted natural nucleic acids and in LNA-DNA or LNA-RNA heteroduplexes has been well investigated, but the X-ray structure of an ;all-locked' nucleic acid double helix has not been described to date. Here, the crystallization and X-ray diffraction data analysis of an 'all-locked' nucleic acid helix, which was designed as an LNA originating from a tRNA(Ser) microhelix RNA structure, is presented. The crystals belonged to space group C2, with unit-cell parameters a = 77.91, b = 40.74, c = 30.06 A, beta = 91.02 degrees . A high-resolution and a low-resolution data set were recorded, with the high-resolution data showing diffraction to 1.9 A resolution. The crystals contained two double helices per asymmetric unit, with a Matthews coefficient of 2.48 A(3) Da(-1) and a solvent content of 66.49% for the merged data.

  8. 35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED LOCK GATES AND TWO SETS OF MACHINERY TO ASSIST IN OPERATING THEM. VIEW FROM THE FAST END OF THE BUILDING LOOKING WEST 1976 - Pawtucket Canal, Guard Locks, Lowell, Middlesex County, MA

  9. Improved performance of a digital phase-locked loop combined with a frequency/frequency-rate estimator

    NASA Technical Reports Server (NTRS)

    Mileant, A.; Simon, M.

    1986-01-01

    When a digital phase-locked loop with a long loop update time tracks a signal with high Doppler, the demodualtion losses due to frequency mismatch can become very significant. One way of reducing these Doppler-related losses is to compensate for the Doppler effect using some kind of frequency-rate estimator. The performance of the fixed-window least-squares estimator and the Kalman filter is investigated; several Doppler compensating techniques are proposed. It is shown that the variance of the frequency estimator can be made as small as desired, and with this, the Doppler effect can be effectively compensated. The remaining demodulation losses due to phase jitter in the loop can be less than 0.1 dB.

  10. Screw-locking wrench

    NASA Technical Reports Server (NTRS)

    Vranish, John M. (Inventor)

    2007-01-01

    A tool comprises a first handle and a second handle, each handle extending from a gripping end portion to a working end portion, the first handle having first screw threads disposed circumferentially about an inner portion of a first through-hole at the working end portion thereof, the second handle having second screw threads disposed circumferentially about an inner portion of a second through-hole at the working end portion thereof, the first and second respective through-holes being disposed concentrically about a common axis of the working end portions. First and second screw locks preferably are disposed concentrically with the first and second respective through-holes, the first screw lock having a plurality of locking/unlocking screw threads for engaging the first screw threads of the first handle, the second screw lock having a plurality of locking/unlocking screw threads for engaging the second screw threads of the second handle. A locking clutch drive, disposed concentrically with the first and second respective through-holes, engages the first screw lock and the second screw lock. The first handle and the second handle are selectively operable at their gripping end portions by a user using a single hand to activate the first and second screw locks to lock the locking clutch drive for either clockwise rotation about the common axis, or counter-clockwise rotation about the common axis, or to release the locking clutch drive so that the handles can be rotated together about the common axis either the clockwise or counter-clockwise direction without rotation of the locking clutch drive.

  11. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  12. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  13. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  14. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  15. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  16. A fast-locking PLL with all-digital locked-aid circuit

    NASA Astrophysics Data System (ADS)

    Kao, Shao-Ku; Hsieh, Fu-Jen

    2013-02-01

    In this article, a fast-locking phase-locked loop (PLL) with an all-digital locked-aid circuit is proposed and analysed. The proposed topology is based on two tuning loops: frequency and phase detections. A frequency detection loop is used to accelerate frequency locking time, and a phase detection loop is used to adjust fine phase errors between the reference and feedback clocks. The proposed PLL circuit is designed based on the 0.35 µm CMOS process with a 3.3 V supply voltage. Experimental results show that the locking time of the proposed PLL achieves a 87.5% reduction from that of a PLL without the locked-aid circuit.

  17. 4. LOOKING NORTHEAST TOWARDS LOCKS. 19TH CENTURY GRAVITY LOCKS ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. LOOKING NORTHEAST TOWARDS LOCKS. 19TH CENTURY GRAVITY LOCKS ON RIGHT. 20TH CENTURY ELECTRIC LIFT LOCKS ON LEFT. - New York State Barge Canal, Lockport Locks, Richmond Avenue, Lockport, Niagara County, NY

  18. Locking design affects the jamming of screws in locking plates.

    PubMed

    Sandriesser, Sabrina; Rupp, Markus; Greinwald, Markus; Heiss, Christian; Augat, Peter; Alt, Volker

    2018-06-01

    The seizing of locking screws is a frequently encountered clinical problem during implant removal of locking compression plates (LCP) after completion of fracture healing. The aim of this study was to investigate the effect of two different locking mechanisms on the seizing of locking screws. Specifically, the removal torques before and after cyclic dynamic loading were assessed for screws inserted at the manufacturer-recommended torque or at an increased insertion torque. The seizing of 3.5-mm angular stable screws was assessed as a function of insertion torque for two different locking mechanisms (Thread & Conus and Thread Only). Locking screws (n=10 for each configuration) were inserted either according to the manufacturer-recommended torque or at an increased torque of 150% to simulate an over-insertion of the screw. Half of the screws were removed directly after insertion and the remaining half was removed after a dynamic load protocol of 100,000 cycles. The removal torques of locking screws exceeded the insertion torques for all tested conditions confirming the adequacy of the test setup in mimicking screw seizing in locked plating. Screw seizing was more pronounced for Thread Only design (+37%) compared to Thread & Conus design (+14%; P<0.0001). Cyclic loading of the locking construct consistently resulted in an increased seizing of the locking screws (P<0.0001). Clinical observations from patients treated with the Thread & Conus locking design confirm the biomechanical findings of reduction in seizing effect by using a Thread & Conus design. In conclusion, both over-tightening and cyclic loading are potential causes for screw seizing in locking plate implants. Both effects were found to be less pronounced in the Thread & Conus design as compared to the traditional Thread Only design. © 2018 Elsevier Ltd. All rights reserved.

  19. Automated Cell Enrichment of Cytomegalovirus-specific T cells for Clinical Applications using the Cytokine-capture System.

    PubMed

    Kumaresan, Pappanaicken; Figliola, Mathew; Moyes, Judy S; Huls, M Helen; Tewari, Priti; Shpall, Elizabeth J; Champlin, Richard; Cooper, Laurence J N

    2015-10-05

    The adoptive transfer of pathogen-specific T cells can be used to prevent and treat opportunistic infections such as cytomegalovirus (CMV) infection occurring after allogeneic hematopoietic stem-cell transplantation. Viral-specific T cells from allogeneic donors, including third party donors, can be propagated ex vivo in compliance with current good manufacturing practice (cGMP), employing repeated rounds of antigen-driven stimulation to selectively propagate desired T cells. The identification and isolation of antigen-specific T cells can also be undertaken based upon the cytokine capture system of T cells that have been activated to secrete gamma-interferon (IFN-γ). However, widespread human application of the cytokine capture system (CCS) to help restore immunity has been limited as the production process is time-consuming and requires a skilled operator. The development of a second-generation cell enrichment device such as CliniMACS Prodigy now enables investigators to generate viral-specific T cells using an automated, less labor-intensive system. This device separates magnetically labeled cells from unlabeled cells using magnetic activated cell sorting technology to generate clinical-grade products, is engineered as a closed system and can be accessed and operated on the benchtop. We demonstrate the operation of this new automated cell enrichment device to manufacture CMV pp65-specific T cells obtained from a steady-state apheresis product obtained from a CMV seropositive donor. These isolated T cells can then be directly infused into a patient under institutional and federal regulatory supervision. All the bio-processing steps including removal of red blood cells, stimulation of T cells, separation of antigen-specific T cells, purification, and washing are fully automated. Devices such as this raise the possibility that T cells for human application can be manufactured outside of dedicated good manufacturing practice (GMP) facilities and instead be produced

  20. Design of Lockage Waiting Areas at L.S.A.F. (Lower Saint Anthony Falls) Lock, Lock Number 2, and Lock Number 3, Upper Mississippi River.

    DTIC Science & Technology

    1980-01-01

    RIVER. 41. PKRFORING ORG. REPORT Nme T% AUTNOR(q) S. CONTRACT OR GRANT NUNUERfa) DACW37-77-C-0148 PERORING ORGANIZATION NAME AND ADDRESS 10. PRGRAM ... prevent erosion. The other facilities provided 7 will be navigation buoys, a lockage waiting area sign, and two trash receptacles. LOCK 2. UPPER APPROACH

  1. Ultralow-field and spin-locking relaxation dispersion in postmortem pig brain.

    PubMed

    Dong, Hui; Hwang, Seong-Min; Wendland, Michael; You, Lixing; Clarke, John; Inglis, Ben

    2017-12-01

    To investigate tissue-specific differences, a quantitative comparison was made between relaxation dispersion in postmortem pig brain measured at ultralow fields (ULF) and spin locking at 7 tesla (T). The goal was to determine whether ULF-MRI has potential advantages for in vivo human brain imaging. Separate specimens of gray matter and white matter were investigated using an ULF-MRI system with superconducting quantum interference device (SQUID) signal detection to measure T1ULF at fields from 58.7 to 235.0 μT and using a commercial MRI scanner to measure T1ρ7T at spin-locking fields from 5.0 to 235.0 μT. At matched field strengths, T1ρ7T is 50 to 100% longer than T1ULF. Furthermore, dispersion in T1ULF is close to linear between 58.7 and 235 µT, whereas dispersion in T1ρ7T is highly nonlinear over the same range. A subtle elbow in the T1ULF dispersion at approximately 140 µT is tentatively attributed to the local dipolar field of macromolecules. It is suggested that different relaxation mechanisms dominate each method and that ULF-MRI has a fundamentally different sensitivity to the macromolecular structure of neural tissue. Ultralow-field MRI may offer distinct, quantitative advantages for human brain imaging, while simultaneously avoiding the severe heating limitation imposed on high-field spin locking. Magn Reson Med 78:2342-2351, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Single-ion quantum lock-in amplifier.

    PubMed

    Kotler, Shlomi; Akerman, Nitzan; Glickman, Yinnon; Keselman, Anna; Ozeri, Roee

    2011-05-05

    Quantum metrology uses tools from quantum information science to improve measurement signal-to-noise ratios. The challenge is to increase sensitivity while reducing susceptibility to noise, tasks that are often in conflict. Lock-in measurement is a detection scheme designed to overcome this difficulty by spectrally separating signal from noise. Here we report on the implementation of a quantum analogue to the classical lock-in amplifier. All the lock-in operations--modulation, detection and mixing--are performed through the application of non-commuting quantum operators to the electronic spin state of a single, trapped Sr(+) ion. We significantly increase its sensitivity to external fields while extending phase coherence by three orders of magnitude, to more than one second. Using this technique, we measure frequency shifts with a sensitivity of 0.42 Hz Hz(-1/2) (corresponding to a magnetic field measurement sensitivity of 15 pT Hz(-1/2)), obtaining an uncertainty of less than 10 mHz (350 fT) after 3,720 seconds of averaging. These sensitivities are limited by quantum projection noise and improve on other single-spin probe technologies by two orders of magnitude. Our reported sensitivity is sufficient for the measurement of parity non-conservation, as well as the detection of the magnetic field of a single electronic spin one micrometre from an ion detector with nanometre resolution. As a first application, we perform light shift spectroscopy of a narrow optical quadrupole transition. Finally, we emphasize that the quantum lock-in technique is generic and can potentially enhance the sensitivity of any quantum sensor. ©2011 Macmillan Publishers Limited. All rights reserved

  3. Automated Formal Testing of C API Using T2C Framework

    NASA Astrophysics Data System (ADS)

    Khoroshilov, Alexey V.; Rubanov, Vladimir V.; Shatokhin, Eugene A.

    A problem of automated test development for checking basic functionality of program interfaces (API) is discussed. Different technologies and corresponding tools are surveyed. And T2C technology developed in ISPRAS is presented. The technology and associated tools facilitate development of "medium quality" (and "medium cost") tests. An important feature of T2C technology is that it enforces that each check in a developed test is explicitly linked to the corresponding place in the standard. T2C tools provide convenient means to create such linkage. The results of using T2C are considered by example of a project for testing interfaces of Linux system libraries defined by the LSB standard.

  4. Framework for Automated GD&T Inspection Using 3D Scanner

    NASA Astrophysics Data System (ADS)

    Pathak, Vimal Kumar; Singh, Amit Kumar; Sivadasan, M.; Singh, N. K.

    2018-04-01

    Geometric Dimensioning and Tolerancing (GD&T) is a typical dialect that helps designers, production faculty and quality monitors to convey design specifications in an effective and efficient manner. GD&T has been practiced since the start of machine component assembly but without overly naming it. However, in recent times industries have started increasingly emphasizing on it. One prominent area where most of the industries struggle with is quality inspection. Complete inspection process is mostly human intensive. Also, the use of conventional gauges and templates for inspection purpose highly depends on skill of workers and quality inspectors. In industries, the concept of 3D scanning is not new but is used only for creating 3D drawings or modelling of physical parts. However, the potential of 3D scanning as a powerful inspection tool is hardly explored. This study is centred on designing a procedure for automated inspection using 3D scanner. Linear, geometric and dimensional inspection of the most popular test bar-stepped bar, as a simple example was also carried out as per the new framework. The new generation engineering industries would definitely welcome this automated inspection procedure being quick and reliable with reduced human intervention.

  5. West Branch Pennsylvania Canal, Lock No. 34 Lock Keeper's House, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    West Branch Pennsylvania Canal, Lock No. 34 Lock Keeper's House, South of State Route 664 along North bank of West Branch of Susquehanna River, 2,000 feet East of Jay Street Bridge, Lock Haven, Clinton County, PA

  6. Supermode-noise-free eighth-order femtosecond soliton from a backward dark-optical-comb-injection mode-locked semiconductor optical amplifier fiber laser.

    PubMed

    Lin, Gong-Ru; Pan, Ci-Ling; Chiu, I-Hsiang

    2006-03-15

    A backward dark-optical-comb-injection mode-locked semiconductor optical amplifier fiber laser (SOAFL) with a femtosecond pulse width and an ultrahigh supermode-noise suppressing ratio (SMSR) is primarily demonstrated. The mode-locked SOAFL pulse with a spectral linewidth of 0.45 nm is shortened from 15 to 8.6 ps under chirp compensation in a 420 m long dispersion-compensated fiber, corresponding to a time-bandwidth product of 0.48. The eighth-order soliton is obtained by the nonlinearly soliton's compression of the chirp-compensated SOAFL pulse in a 112 m long single-mode fiber at an input peak power of 51 W, providing the pulse width, the linewidth, and the nearly transform-limited time-bandwidth product are <200 fs, 13.8 nm, and 0.34, respectively. The phase noise and integrated timing jitter at an offset frequency below 1 MHz are -105 dBc/Hz and 0.8 ps, respectively. An ultrahigh pulse-compression ratio of 43 and a SMSR of 87 dB for the eighth-order SOAFL soliton are reported.

  7. All-fiber nonlinearity- and dispersion-managed dissipative soliton nanotube mode-locked laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Z.; Nanjing University of Posts and Communications, Nanjing 210003; Popa, D., E-mail: dp387@cam.ac.uk

    We report dissipative soliton generation from an Yb-doped all-fiber nonlinearity- and dispersion-managed nanotube mode-locked laser. A simple all-fiber ring cavity exploits a photonic crystal fiber for both nonlinearity enhancement and dispersion compensation. The laser generates stable dissipative solitons with large linear chirp in the net normal dispersion regime. Pulses that are 8.7 ps long are externally compressed to 118 fs, outperforming current nanotube-based Yb-doped fiber laser designs.

  8. Compensation for z-directional non-uniformity of a monopole antenna at 7T MRI

    NASA Astrophysics Data System (ADS)

    Kim, Nambeom; Woo, Myung-Kyun; Kang, Chang-Ki

    2016-06-01

    The research was conducted to find ways to compensate for z-directional non-uniformity at a monopole antenna array (MA) coil by using a tilted optimized non-saturating excitation (TONE) pulse and to evaluate the feasibility of using the MA coil with the TONE pulse for anatomical and angiographic imaging. The sensitivity of a MA coil along the z-direction was measured by using an actual flip angle imaging pulse sequence with an oil phantom to evaluate the flip angle distributions of the MA coil for 7T magnetic resonance imaging (MRI). The effects on the z-directional uniformity were examined by using slow and fast TONE pulses, i.e., TONE SLOW and TONE FAST. T1- and T2* -weighted images of the human brain were also examined. The z-directional profiles of the TONE pulses were analyzed by using the average signal intensity throughout the brain. The effect of the TONE pulses on cerebral vessels was further examined by analyzing maximal intensity projections of T1-weighted images. With increasing the applied flip angles, the sensitivity slope slightly increased (0.044 per degree). For the MA coil, the TONE SLOWpulse yielded a compensated profile along the z-direction while the TONE HIGH pulse, which has a flat excitation profile along the z-direction, exhibited a tilted signal intensity toward the coil end, clearly indicating an intrinsic property of the MA coil. Similar to the phantom study, human brain images revealed z-directional symmetry around the peak value for the averaged signal intensity of the TONE SLOW pulse while the TONE HIGH pulse exhibited a tilted signal intensity toward the coil end. In vascular system imaging, the MA coil also clearly demonstrated a beneficial effect on the cerebral vessels, either with or without the TONE pulses. This study demonstrates that TONE pulses could compensate for the intrinsic z-directional non-uniformity of MA coils that exhibit strong uniformity in the x-y plane. Furthermore, tilted pulses, such as TONE pulses, were

  9. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    PubMed

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation

  10. Interband optical pulse injection locking of quantum dot mode-locked semiconductor laser.

    PubMed

    Kim, Jimyung; Delfyett, Peter J

    2008-07-21

    We experimentally demonstrate optical clock recovery from quantum dot mode-locked semiconductor lasers by interband optical pulse injection locking. The passively mode-locked slave laser oscillating on the ground state or the first excited state transition is locked through the injection of optical pulses generated via the opposite transition bands, i.e. the first excited state or the ground state transition from the hybridly mode-locked master laser, respectively. When an optical pulse train generated via the first excited state from the master laser is injected to the slave laser oscillating via ground state, the slave laser shows an asymmetric locking bandwidth around the nominal repetition rate of the slave laser. In the reverse injection case of, i.e. the ground state (master laser) to the first excited state (slave laser), the slave laser does not lock even though both lasers oscillate at the same cavity frequency. In this case, the slave laser only locks to higher injection rates as compared to its own nominal repetition rate, and also shows a large locking bandwidth of 6.7 MHz.

  11. Locking mechanism

    DOEpatents

    Williams, Gary L.; Goin, Jr., Jesse L.; Kirby, Patrick G.; McKenna, John P.

    1997-01-01

    The invention is a motorized linkage for operating a door strike. A six volt power source, controlled by a security code, rotates a small electric motor when a proper security code is given. The motor rotates a shaft which engages a coil spring. This moves a locking cam. When a catch on the locking cam separates from the locking lever catch, the latch bolt keeper may be manipulated by a user.

  12. Exchange-Mediated Contrast Agents for Spin-Lock Imaging

    PubMed Central

    Cobb, Jared G.; Xie, Jingping; Li, Ke; Gochberg, Daniel F.; Gore, John C.

    2011-01-01

    Measurements of relaxation rates in the rotating frame with spin-locking (SL) techniques are sensitive to substances with exchanging protons with appropriate chemical shifts. We develop a novel approach to exchange rate selective imaging based on measured T1ρ dispersion with applied locking field strength, and demonstrate the method on samples containing the X-ray contrast agent Iohexol (IO) with and without cross-linked bovine serum albumin (BSA). T1ρ dispersion of water in the phantoms was measured with a Varian 9.4T magnet by an on-resonance SL pulse with fast spin-echo readout, and the results used to estimate exchange rates. The IO phantom alone gave a fitted exchange rate of ~1 kHz, BSA alone was ~11 kHz, and in combination gave rates in between. By using these estimated rates, we demonstrate how a novel SL imaging method may be used to enhance contrast due to the presence of a contrast agent whose protons have specific exchange rates. PMID:21954094

  13. Dynamic Locked Plating of Distal Femur Fractures.

    PubMed

    Linn, Michael S; McAndrew, Christopher M; Prusaczyk, Beth; Brimmo, Olubusola; Ricci, William M; Gardner, Michael J

    2015-10-01

    Nonunion after locked bridge plating of comminuted distal femur fractures is not uncommon. "Dynamic" locked plating may create an improved mechanical environment, thereby achieving higher union rates than standard locked plating constructs. Academic Level 1 Trauma Center. Twenty-eight patients with comminuted supracondylar femur fractures treated with either dynamic or standard locked plating. Dynamic plating was achieved using an overdrilling technique of the near cortex to allow for a 0.5-mm "halo" around the screw shaft at the near cortex. Standard locked plating was done based on manufacturer's suggested technique. The patients treated with dynamic plating were matched 1:1 with those treated with standard locked plating based on OTA classification and working length. Three blinded observers made callus measurements on 6-week radiographs using a 4-point ordinal scale. The results were analyzed using a 2-tailed t test and 2-way intraclass correlations. The dynamic plating group had significantly greater callus (2.0; SD, 0.7) compared with the control group (1.3: SD, 0.8, P = 0.048) with substantial agreement amongst observers in both consistency (0.724) and absolute score (0.734). With dynamic plating group, 1 patient failed to unite, versus three in the control group (P = 0.59). The dynamic group had a mean change in coronal plane alignment of 0.5 degrees (SD, 2.6) compared with 0.6 (SD, 3.0) for the control group (P = 0.9) without fixation failure in either group. Overdrilling the near cortex in metaphyseal bridge plating can be adapted to standard implants to create a dynamic construct and increase axial motion. This technique seems to be safe and leads to increased callus formation, which may decrease nonunion rates seen with standard locked plating. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Femtosecond wavelength tunable semiconductor optical amplifier fiber laser mode-locked by backward dark-optical-comb injection at 10 GHz.

    PubMed

    Lin, Gong-Ru; Chiu, I-Hsiang

    2005-10-31

    Femtosecond nonlinear pulse compression of a wavelength-tunable, backward dark-optical-comb injection harmonic-mode-locked semiconductor optical amplifier based fiber laser (SOAFL) is demonstrated for the first time. Shortest mode-locked SOAFL pulsewidth of 15 ps at 1 GHz is generated, which can further be compressed to 180 fs after linear chirp compensation, nonlinear soliton compression, and birefringent filtering. A maximum pulsewidth compression ratio for the compressed eighth-order SOAFL soliton of up to 80 is reported. The pedestal-free eighth-order soliton can be obtained by injecting the amplified pulse with peak power of 51 W into a 107.5m-long single-mode fiber (SMF), providing a linewidth and time-bandwidth product of 13.8 nm and 0.31, respectively. The tolerance in SMF length is relatively large (100-300 m) for obtaining <200fs SOAFL pulsewidth at wavelength tuning range of 1530-1560 nm. By extending the repetition frequency of dark-optical-comb up to 10 GHz, the mode-locked SOAFL pulsewidth can be slightly shortened from 5.4 ps to 3.9 ps after dispersion compensating, and further to 560 fs after second-order soliton compression. The lasing linewidth, time-bandwidth product and pulsewidth suppressing ratio of the SOAFL soliton become 4.5 nm, 0.33, and 10, respectively.

  15. Target-in-the-loop high-power adaptive phase-locked fiber laser array using single-frequency dithering technique

    NASA Astrophysics Data System (ADS)

    Tao, R.; Ma, Y.; Si, L.; Dong, X.; Zhou, P.; Liu, Z.

    2011-11-01

    We present a theoretical and experimental study of a target-in-the-loop (TIL) high-power adaptive phase-locked fiber laser array. The system configuration of the TIL adaptive phase-locked fiber laser array is introduced, and the fundamental theory for TIL based on the single-dithering technique is deduced for the first time. Two 10-W-level high-power fiber amplifiers are set up and adaptive phase locking of the two fiber amplifiers is accomplished successfully by implementing a single-dithering algorithm on a signal processor. The experimental results demonstrate that the optical phase noise for each beam channel can be effectively compensated by the TIL adaptive optics system under high-power applications and the fringe contrast on a remotely located extended target is advanced from 12% to 74% for the two 10-W-level fiber amplifiers.

  16. Optically Phase-Locked Electronic Speckle Pattern Interferometer (OPL-ESPI)

    NASA Astrophysics Data System (ADS)

    Moran, Steven E.; Law, Robert L.; Craig, Peter N.; Goldberg, Warren M.

    1986-10-01

    This report describes the design, theory, operation, and characteristics of the OPL-ESPI, which generates real time equal Doppler speckle contours of vibrating objects from unstable sensor platforms with a Doppler resolution of 30 Hz and a maximum tracking range of + or - 5 HMz. The optical phase locked loop compensates for the deleterious effects of ambient background vibration and provides the bases for a new ESPI video signal processing technique, which produces high contrast speckle contours. The OPL-ESPI system has local oscillator phase modulation capability, offering the potential for detection of vibrations with the amplitudes less than lambda/100.

  17. Automated Characterization of Rotating MHD Modes and Subsequent Locking in a Tokamak

    NASA Astrophysics Data System (ADS)

    Riquezes, Juan; Sabbagh, Steven; Berkery, Jack

    2016-10-01

    Disruption avoidance in tokamaks is highly desired to maintain steady plasma operation, and is critical for future reactor-scale devices, such as ITER, to avoid potential damage to device components. This high priority research is being conducted at PPPL by analyzing data from NSTX and its upgrade, NSTX-U. A key cause of disruptions is the physical event chain that comprises the appearance of rotating MHD modes, their slowing by resonant field drag mechanisms, and their subsequent locking. The present research aims to define algorithms to automatically find and characterize such physical event chains in the machine database. Characteristics such as identification of a mode locking time based on a loss of torque balance and bifurcation of the mode rotation frequency are examined to determine the reliability of such events in predicting disruptions. A goal is to detect such behavior as early as possible during a plasma discharge, and to further examine potential ways to forecast it. This capability could be used to provide a warning to use active mode control as a disruption avoidance mechanism, or to trigger a controlled plasma shutdown if desired. Supported by US DOE Contracts DE-FG02-99ER54524 and DE-AC02-09CH11466.

  18. Automatic NMR field-frequency lock-pulsed phase locked loop approach.

    PubMed

    Kan, S; Gonord, P; Fan, M; Sauzade, M; Courtieu, J

    1978-06-01

    A self-contained deuterium frequency-field lock scheme for a high-resolution NMR spectrometer is described. It is based on phase locked loop techniques in which the free induction decay signal behaves as a voltage-controlled oscillator. By pulsing the spins at an offset frequency of a few hundred hertz and using a digital phase-frequency discriminator this method not only eliminates the usual phase, rf power, offset adjustments needed in conventional lock systems but also possesses the automatic pull-in characteristics that dispense with the use of field sweeps to locate the NMR line prior to closure of the lock loop.

  19. A compensation scheme for tape-speed variation in cassette recorders.

    PubMed

    Wodicka, G R; Aguirre, A; Burns, S K; Shannon, D C

    1988-06-01

    A scheme to reduce the data corruption caused by tape-speed variation in cassette recorders used for monitoring infant apnea was developed. Low-frequency timing information is recorded on the tape, under the constraints of the frequency response of the recorder, simultaneously with the other signals. This information is extracted during playback and multiplied to a frequency suitable for data sampling, using an electronic, phase-locked loop. Analog-to-digital conversion of the data is performed at a rate proportional to the tape speed, resulting in compensation for speed variation. No direct modification of the speed-control mechanism of the recorder is required. The scheme was evaluated by comparing interval measurements of recorded timing information with and without compensation. Compensation reduced the error of the measurement by nearly an order of magnitude, which was consistent with theoretical predictions. This allows analysis of clinical value to be performed on signals recorded by systems that lack sophisticated speed-control mechanisms.

  20. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    PubMed

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  1. Robust terahertz self-heterodyne system using a phase noise compensation technique.

    PubMed

    Song, Hajun; Song, Jong-In

    2015-08-10

    We propose and demonstrate a robust terahertz self-heterodyne system using a phase noise compensation technique. Conventional terahertz self-heterodyne systems suffer from degraded phase noise performance due to phase noise of the laser sources. The proposed phase noise compensation technique uses an additional photodiode and a simple electric circuit to produce phase noise identical to that observed in the terahertz signal produced by the self-heterodyne system. The phase noise is subsequently subtracted from the terahertz signal produced by the self-heterodyne system using a lock-in amplifier. While the terahertz self-heterodyne system using a phase noise compensation technique offers improved phase noise performance, it also provides a reduced phase drift against ambient temperature variations. The terahertz self-heterodyne system using a phase noise compensation technique shows a phase noise of 0.67 degree in terms of a standard deviation value even without using overall delay balance control. It also shows a phase drift of as small as approximately 10 degrees in an open-to-air measurement condition without any strict temperature control.

  2. Locked modes in two reversed-field pinch devices of different size and shell system

    NASA Astrophysics Data System (ADS)

    Malmberg, J.-A.; Brunsell, P. R.; Yagi, Y.; Koguchi, H.

    2000-10-01

    The behavior of locked modes in two reversed-field pinch devices, the Toroidal Pinch Experiment (TPE-RX) [Y. Yagi et al., Plasma Phys. Control. Fusion 41, 2552 (1999)] and Extrap T2 [J. R. Drake et al., in Plasma Physics and Controlled Nuclear Fusion Research 1996, Montreal (International Atomic Energy Agency, Vienna, 1996), Vol. 2, p. 193] is analyzed and compared. The main characteristics of the locked mode are qualitatively similar. The toroidal distribution of the mode locking shows that field errors play a role in both devices. The probability of phase locking is found to increase with increasing magnetic fluctuation levels in both machines. Furthermore, the probability of phase locking increases with plasma current in TPE-RX despite the fact that the magnetic fluctuation levels decrease. A comparison with computations using a theoretical model estimating the critical mode amplitude for locking [R. Fitzpatrick et al., Phys. Plasmas 6, 3878 (1999)] shows a good correlation with experimental results in TPE-RX. In Extrap T2, the magnetic fluctuations scale weakly with both plasma current and electron densities. This is also reflected in the weak scaling of the magnetic fluctuation levels with the Lundquist number (˜S-0.06). In TPE-RX, the corresponding scaling is ˜S-0.18.

  3. Temperature-Compensated Clock Skew Adjustment

    PubMed Central

    Castillo-Secilla, Jose María; Palomares, Jose Manuel; Olivares, Joaquín

    2013-01-01

    This work analyzes several drift compensation mechanisms in wireless sensor networks (WSN). Temperature is an environmental factor that greatly affects oscillators shipped in every WSN mote. This behavior creates the need of improving drift compensation mechanisms in synchronization protocols. Using the Flooding Time Synchronization Protocol (FTSP), this work demonstrates that crystal oscillators are affected by temperature variations. Thus, the influence of temperature provokes a low performance of FTSP in changing conditions of temperature. This article proposes an innovative correction factor that minimizes the impact of temperature in the clock skew. By means of this factor, two new mechanisms are proposed in this paper: the Adjusted Temperature (AT) and the Advanced Adjusted Temperature (A2T). These mechanisms have been combined with FTSP to produce AT-FTSP and A2T-FTSP Both have been tested in a network of TelosB motes running TinyOS. Results show that both AT-FTSP and A2T-FTSP improve the average synchronization errors compared to FTSP and other temperature-compensated protocols (Environment-Aware Clock Skew Estimation and Synchronization for WSN (EACS) and Temperature Compensated Time Synchronization (TCTS)). PMID:23966192

  4. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lakeman, T; Wang, I; Podgorsak, M

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CTmore » data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the

  5. Distal tibia fractures: locked or non-locked plating? A systematic review of outcomes.

    PubMed

    Khalsa, Amrit S; Toossi, Nader; Tabb, Loni P; Amin, Nirav H; Donohue, Kenneth W; Cerynik, Douglas L

    2014-06-01

    Although plating is considered to be the treatment of choice in distal tibia fractures, controversies abound regarding the type of plating for optimal fixation. We conducted a systematic review to evaluate and compare the outcomes of locked plating and non-locked plating in treatment of distal tibia fractures. A systematic review was conducted using PubMed to identify articles on the outcomes of plating in distal tibia fractures that were published up to June 2012. We included English language articles involving a minimum of 10 adult cases with acute fractures treated using single-plate, minimally invasive techniques. Study-level binomial regression on the pooled data was conducted to determine the effect of locking status on different outcomes, adjusted for age, sex, and other independent variables. 27 studies met the inclusion criteria and were included in the final analysis of 764 cases (499 locking, 265 non-locking). Based on descriptive analysis only, delayed union was reported in 6% of cases with locked plating and in 4% of cases with non-locked plating. Non-union was reported in 2% of cases with locked plating and 3% of cases with non-locked plating. Comparing locked and non-locked plating, the odds ratio (OR) for reoperation was 0.13 (95% CI: 0.03-0.57) and for malalignment it was 0.10 (95% CI: 0.02-0.42). Both values were statistically significant. This study showed that locked plating reduces the odds of reoperation and malalignment after treatment for acute distal tibia fracture. Future studies should accurately assess causality and the clinical and economic impact of these findings.

  6. Specimen coordinate automated measuring machine/fiducial automated measuring machine

    DOEpatents

    Hedglen, Robert E.; Jacket, Howard S.; Schwartz, Allan I.

    1991-01-01

    The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

  7. Locke and botany.

    PubMed

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  8. A novel injection-locked amplitude-modulated magnetron at 1497 MHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neubauer, Michael; Wang, Haipeng

    2015-12-15

    Thomas Jefferson National Accelerator Facility (JLab) uses low efficiency klystrons in the CEBAF machine. In the older portion they operate at 30% efficiency with a tube mean time between failure (MTBF) of five to six years. A highly efficient source (>55-60%) must provide a high degree of backwards compatibility, both in size and voltage requirements, to replace the klystron presently used at JLab, while providing energy savings. Muons, Inc. is developing a highly reliable, highly efficient RF source based upon a novel injection-locked amplitude modulated (AM) magnetron with a lower total cost of ownership, >80% efficiency, and MTBF of sixmore » to seven years. The design of the RF source is based upon a single injection-locked magnetron system at 8 kW capable of operating up to 13 kW, using the magnetron magnetic field to achieve the AM required for backwards compatibility to compensate for microphonics and beam loads. A novel injection-locked 1497 MHz 8 kW AM magnetron with a trim magnetic coil was designed and its operation numerically simulated during the Phase I project. The low-level RF system to control the trim field and magnetron anode voltage was designed and modeled for operation at the modulation frequencies of the microphonics. A plan for constructing a prototype magnetron and control system was developed.« less

  9. Optically stabilized Erbium fiber frequency comb with hybrid mode-locking and a broad tunable range of repetition rate.

    PubMed

    Yang, Honglei; Wu, Xuejian; Zhang, Hongyuan; Zhao, Shijie; Yang, Lijun; Wei, Haoyun; Li, Yan

    2016-12-01

    We present an optically stabilized Erbium fiber frequency comb with a broad repetition rate tuning range based on a hybrid mode-locked oscillator. We lock two comb modes to narrow-linewidth reference lasers in turn to investigate the best performance of control loops. The control bandwidth of fast and slow piezoelectric transducers reaches 70 kHz, while that of pump current modulation with phase-lead compensation is extended to 32 kHz, exceeding laser intrinsic response. Eventually, simultaneous lock of both loops is realized to totally phase-stabilize the comb, which will facilitate precision dual-comb spectroscopy, laser ranging, and timing distribution. In addition, a 1.8-MHz span of the repetition rate is achieved by an automatic optical delay line that is helpful in manufacturing a secondary comb with a similar repetition rate. The oscillator is housed in a homemade temperature-controlled box with an accuracy of ±0.02  K, which not only keeps high signal-to-noise ratio of the beat notes with reference lasers, but also guarantees self-starting at the same mode-locking every time.

  10. Electronic locking system

    NASA Astrophysics Data System (ADS)

    Nieuwkoop, E.

    An electronic locking system was developed to remove the disadvantages of conventional mechanical door locks. The electrolock has to replace existing locks. Therefore, the techniques of Surface Mount Technology and Application Specific Integrated Circuit were applied to overcome the space limitations. The key consists of a metal rod with grip equipped with a contactless chip. When the key is inserted in the lock, a magnetic field is generated in the cylinder which induces a voltage in the chip. Therefore a battery is not required. The chip then emits inductively a code which is unique for each key. The electrolock was successfully tested.

  11. Cavity-locked ring down spectroscopy

    DOEpatents

    Zare, Richard N.; Paldus, Barbara A.; Harb, Charles C.; Spence, Thomas

    2000-01-01

    Distinct locking and sampling light beams are used in a cavity ring-down spectroscopy (CRDS) system to perform multiple ring-down measurements while the laser and ring-down cavity are continuously locked. The sampling and locking light beams have different frequencies, to ensure that the sampling and locking light are decoupled within the cavity. Preferably, the ring-down cavity is ring-shaped, the sampling light is s-polarized, and the locking light is p-polarized. Transmitted sampling light is used for ring-down measurements, while reflected locking light is used for locking in a Pound-Drever scheme.

  12. Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator

    PubMed Central

    Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2014-01-01

    This paper presents a technique for automated intraocular laser surgery using a handheld micromanipulator known as Micron. The novel handheld manipulator enables the automated scanning of a laser probe within a cylinder of 4 mm long and 4 mm in diameter. For the automation, the surface of the retina is reconstructed using a stereomicroscope, and then preplanned targets are placed on the surface. The laser probe is precisely located on the target via visual servoing of the aiming beam, while maintaining a specific distance above the surface. In addition, the system is capable of tracking the surface of the eye in order to compensate for any eye movement introduced during the operation. We compared the performance of the automated scanning using various control thresholds, in order to find the most effective threshold in terms of accuracy and speed. Given the selected threshold, we conducted the handheld operation above a fixed target surface. The average error and execution time are reduced by 63.6% and 28.5%, respectively, compared to the unaided trials. Finally, the automated laser photocoagulation was demonstrated also in an eye phantom, including compensation for the eye movement. PMID:25893135

  13. Automated assembly of VECSEL components

    NASA Astrophysics Data System (ADS)

    Brecher, C.; Pyschny, N.; Haag, S.; Mueller, T.

    2013-02-01

    Due to the architectural advantage of an external cavity architecture that enables the integration of additional elements into the cavity (e.g. for mode control, frequency conversion, wavelength tuning or passive mode-locking) VECSELs are a rapidly developing laser technology. Nevertheless they often have to compete with direct (edge) emitting laser diodes which can have significant cost advantages thanks to their rather simple structure and production processes. One way to compensate the economical disadvantages of VECSELs is to optimize each component in terms of quality and costs and to apply more efficient (batch) production processes. In this context, the paper presents recent process developments for the automated assembly of VECSELs using a new type of desktop assembly station with an ultra-precise micromanipulator. The core concept is to create a dedicated process development environment from which implemented processes can be transferred fluently to production equipment. By now two types of processes have been put into operation on the desktop assembly station: 1.) passive alignment of the pump optics implementing a camera-based alignment process, where the pump spot geometry and position on the semiconductor chip is analyzed and evaluated; 2.) active alignment of the end mirror based on output power measurements and optimization algorithms. In addition to the core concept and corresponding hardware and software developments, detailed results of both processes are presented explaining measurement setups as well as alignment strategies and results.

  14. Fast flux locked loop

    DOEpatents

    Ganther, Jr., Kenneth R.; Snapp, Lowell D.

    2002-09-10

    A flux locked loop for providing an electrical feedback signal, the flux locked loop employing radio-frequency components and technology to extend the flux modulation frequency and tracking loop bandwidth. The flux locked loop of the present invention has particularly useful application in read-out electronics for DC SQUID magnetic measurement systems, in which case the electrical signal output by the flux locked loop represents an unknown magnetic flux applied to the DC SQUID.

  15. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  16. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  17. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  18. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  19. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  20. Lock For Valve Stem

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.; Guirguis, Kamal S.

    1991-01-01

    Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.

  1. Automated Enrichment, Transduction, and Expansion of Clinical-Scale CD62L+ T Cells for Manufacturing of Gene Therapy Medicinal Products

    PubMed Central

    Priesner, Christoph; Aleksandrova, Krasimira; Esser, Ruth; Mockel-Tenbrinck, Nadine; Leise, Jana; Drechsel, Katharina; Marburger, Michael; Quaiser, Andrea; Goudeva, Lilia; Arseniev, Lubomir; Kaiser, Andrew D.; Glienke, Wolfgang; Koehl, Ulrike

    2016-01-01

    Multiple clinical studies have demonstrated that adaptive immunotherapy using redirected T cells against advanced cancer has led to promising results with improved patient survival. The continuously increasing interest in those advanced gene therapy medicinal products (GTMPs) leads to a manufacturing challenge regarding automation, process robustness, and cell storage. Therefore, this study addresses the proof of principle in clinical-scale selection, stimulation, transduction, and expansion of T cells using the automated closed CliniMACS® Prodigy system. Naïve and central memory T cells from apheresis products were first immunomagnetically enriched using anti-CD62L magnetic beads and further processed freshly (n = 3) or split for cryopreservation and processed after thawing (n = 1). Starting with 0.5 × 108 purified CD3+ T cells, three mock runs and one run including transduction with green fluorescent protein (GFP)-containing vector resulted in a median final cell product of 16 × 108 T cells (32-fold expansion) up to harvesting after 2 weeks. Expression of CD62L was downregulated on T cells after thawing, which led to the decision to purify CD62L+CD3+ T cells freshly with cryopreservation thereafter. Most important in the split product, a very similar expansion curve was reached comparing the overall freshly CD62L selected cells with those after thawing, which could be demonstrated in the T cell subpopulations as well by showing a nearly identical conversion of the CD4/CD8 ratio. In the GFP run, the transduction efficacy was 83%. In-process control also demonstrated sufficient glucose levels during automated feeding and medium removal. The robustness of the process and the constant quality of the final product in a closed and automated system give rise to improve harmonized manufacturing protocols for engineered T cells in future gene therapy studies. PMID:27562135

  2. Experimental quantum data locking

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Cao, Zhu; Wu, Cheng; Fukuda, Daiji; You, Lixing; Zhong, Jiaqiang; Numata, Takayuki; Chen, Sijing; Zhang, Weijun; Shi, Sheng-Cai; Lu, Chao-Yang; Wang, Zhen; Ma, Xiongfeng; Fan, Jingyun; Zhang, Qiang; Pan, Jian-Wei

    2016-08-01

    Classical correlation can be locked via quantum means: quantum data locking. With a short secret key, one can lock an exponentially large amount of information in order to make it inaccessible to unauthorized users without the key. Quantum data locking presents a resource-efficient alternative to one-time pad encryption which requires a key no shorter than the message. We report experimental demonstrations of a quantum data locking scheme originally proposed by D. P. DiVincenzo et al. [Phys. Rev. Lett. 92, 067902 (2004), 10.1103/PhysRevLett.92.067902] and a loss-tolerant scheme developed by O. Fawzi et al. [J. ACM 60, 44 (2013), 10.1145/2518131]. We observe that the unlocked amount of information is larger than the key size in both experiments, exhibiting strong violation of the incremental proportionality property of classical information theory. As an application example, we show the successful transmission of a photo over a lossy channel with quantum data (un)locking and error correction.

  3. Phase locked loop synchronization for direct detection optical PPM communication systems

    NASA Technical Reports Server (NTRS)

    Chen, C. C.; Gardner, C. S.

    1985-01-01

    Receiver timing synchronization of an optical pulse position modulation (PPM) communication system can be achieved using a phase locked loop (PLL) if the photodetector output is properly processed. The synchronization performance is shown to improve with increasing signal power and decreasing loop bandwidth. Bit error rate (BER) of the PLL synchronized PPM system is analyzed and compared to that for the perfectly synchronized system. It is shown that the increase in signal power needed to compensate for the imperfect synchronization is small (less than 0.1 dB) for loop bandwidths less than 0.1% of the slot frequency.

  4. Dispersion compensated mid-infrared quantum cascade laser frequency comb with high power output

    NASA Astrophysics Data System (ADS)

    Lu, Q. Y.; Manna, S.; Slivken, S.; Wu, D. H.; Razeghi, M.

    2017-04-01

    Chromatic dispersion control plays an underlying role in optoelectronics and spectroscopy owing to its enhancement to nonlinear interactions by reducing the phase mismatching. This is particularly important to optical frequency combs based on quantum cascade lasers which require negligible dispersions for efficient mode locking of the dispersed modes into equally spaced comb modes. Here, we demonstrated a dispersion compensated mid-IR quantum cascade laser frequency comb with high power output at room temperature. A low-loss dispersive mirror has been engineered to compensate the device's dispersion residue for frequency comb generation. Narrow intermode beating linewidths of 40 Hz in the comb-working currents were identified with a high power output of 460 mW and a broad spectral coverage of 80 cm-1. This dispersion compensation technique will enable fast spectroscopy and high-resolution metrology based on QCL combs with controlled dispersion and suppressed noise.

  5. 49 CFR 236.745 - Face, locking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Face, locking. 236.745 Section 236.745 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Face, locking. The locking surface of a locking dog, tappet or cross locking of an interlocking machine. ...

  6. 49 CFR 236.745 - Face, locking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Face, locking. 236.745 Section 236.745 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Face, locking. The locking surface of a locking dog, tappet or cross locking of an interlocking machine. ...

  7. 49 CFR 236.745 - Face, locking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Face, locking. 236.745 Section 236.745 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Face, locking. The locking surface of a locking dog, tappet or cross locking of an interlocking machine. ...

  8. 49 CFR 236.745 - Face, locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Face, locking. 236.745 Section 236.745 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Face, locking. The locking surface of a locking dog, tappet or cross locking of an interlocking machine. ...

  9. 49 CFR 236.745 - Face, locking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Face, locking. 236.745 Section 236.745 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Face, locking. The locking surface of a locking dog, tappet or cross locking of an interlocking machine. ...

  10. First experimental demonstration of self-synchronous locking of optical coherence by single-detector electronic-frequency tagging of fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Shay, T. M.; Benham, Vincent; Baker, J. T.; Ward, Benjamin; Sanchez, Anthony D.; Culpepper, Mark A.; Pilkington, D.; Spring, Justin; Nelson, Douglas J.; Lu, Chunte A.

    2006-08-01

    A novel high accuracy all electronic technique for phase locking arrays of optical fibers is demonstrated. We report the first demonstration of the only electronic phase locking technique that doesn't require a reference beam. The measured phase error is λ/20. Excellent phase locking has been demonstrated for fiber amplifier arrays.

  11. 26 CFR 1.404(b)-1T - Method or arrangement of contributions, etc., deferring the receipt of compensation or providing...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... deduction of vacation pay by a taxpayer that has elected the application of such section. For rules relating... 419, § 1.419-1T and § 1.419A-2T. For rules relating to the deduction of vacation pay for which an... receives compensation or benefits more than a brief period of time after the end of the employer's taxable...

  12. 26 CFR 1.404(b)-1T - Method or arrangement of contributions, etc., deferring the receipt of compensation or providing...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... deduction of vacation pay by a taxpayer that has elected the application of such section. For rules relating... 419, § 1.419-1T and § 1.419A-2T. For rules relating to the deduction of vacation pay for which an... receives compensation or benefits more than a brief period of time after the end of the employer's taxable...

  13. On families of differential equations on two-torus with all phase-lock areas

    NASA Astrophysics Data System (ADS)

    Glutsyuk, Alexey; Rybnikov, Leonid

    2017-01-01

    We consider two-parametric families of non-autonomous ordinary differential equations on the two-torus with coordinates (x, t) of the type \\overset{\\centerdot}{{x}} =v(x)+A+Bf(t) . We study its rotation number as a function of the parameters (A, B). The phase-lock areas are those level sets of the rotation number function ρ =ρ (A,B) that have non-empty interiors. Buchstaber, Karpov and Tertychnyi studied the case when v(x)=\\sin x in their joint paper. They observed the quantization effect: for every smooth periodic function f(t) the family of equations may have phase-lock areas only for integer rotation numbers. Another proof of this quantization statement was later obtained in a joint paper by Ilyashenko, Filimonov and Ryzhov. This implies a similar quantization effect for every v(x)=a\\sin (mx)+b\\cos (mx)+c and rotation numbers that are multiples of \\frac{1}{m} . We show that for every other analytic vector field v(x) (i.e. having at least two Fourier harmonics with non-zero non-opposite degrees and nonzero coefficients) there exists an analytic periodic function f(t) such that the corresponding family of equations has phase-lock areas for all the rational values of the rotation number.

  14. Critical error fields for locked mode instability in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Haye, R.J.; Fitzpatrick, R.; Hender, T.C.

    1992-07-01

    Otherwise stable discharges can become nonlinearly unstable to disruptive locked modes when subjected to a resonant {ital m}=2, {ital n}=1 error field from irregular poloidal field coils, as in DIII-D (Nucl. Fusion {bold 31}, 875 (1991)), or from resonant magnetic perturbation coils as in COMPASS-C ({ital Proceedings} {ital of} {ital the} 18{ital th} {ital European} {ital Conference} {ital on} {ital Controlled} {ital Fusion} {ital and} {ital Plasma} {ital Physics}, Berlin (EPS, Petit-Lancy, Switzerland, 1991), Vol. 15C, Part II, p. 61). Experiments in Ohmically heated deuterium discharges with {ital q}{approx}3.5, {ital {bar n}} {approx} 2 {times} 10{sup 19} m{sup {minus}3} andmore » {ital B}{sub {ital T}} {approx} 1.2 T show that a much larger relative error field ({ital B}{sub {ital r}21}/{ital B}{sub {ital T}} {approx} 1 {times} 10{sup {minus}3}) is required to produce a locked mode in the small, rapidly rotating plasma of COMPASS-C ({ital R}{sub 0} = 0.56 m, {ital f}{approx}13 kHz) than in the medium-sized plasmas of DIII-D ({ital R}{sub 0} = 1.67 m, {ital f}{approx}1.6 kHz), where the critical relative error field is {ital B}{sub {ital r}21}/{ital B}{sub {ital T}} {approx} 2 {times} 10{sup {minus}4}. This dependence of the threshold for instability is explained by a nonlinear tearing theory of the interaction of resonant magnetic perturbations with rotating plasmas that predicts the critical error field scales as ({ital fR}{sub 0}/{ital B}{sub {ital T}}){sup 4/3}{ital {bar n}}{sup 2/3}. Extrapolating from existing devices, the predicted critical field for locked modes in Ohmic discharges on the International Thermonuclear Experimental Reactor (ITER) (Nucl. Fusion {bold 30}, 1183 (1990)) ({ital f}=0.17 kHz, {ital R}{sub 0} = 6.0 m, {ital B}{sub {ital T}} = 4.9 T, {ital {bar n}} = 2 {times} 10{sup 19} m{sup {minus}3}) is {ital B}{sub {ital r}21}/{ital B}{sub {ital T}} {approx} 2 {times} 10{sup {minus}5}.« less

  15. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers

    PubMed Central

    Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-01-01

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio (C/N0) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C/N0 can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis. PMID:29207546

  16. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers.

    PubMed

    Jin, Tian; Yuan, Heliang; Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-12-04

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio ( C / N ₀) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C / N ₀ can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis.

  17. Laser beam projection with adaptive array of fiber collimators. II. Analysis of atmospheric compensation efficiency.

    PubMed

    Lachinova, Svetlana L; Vorontsov, Mikhail A

    2008-08-01

    We analyze the potential efficiency of laser beam projection onto a remote object in atmosphere with incoherent and coherent phase-locked conformal-beam director systems composed of an adaptive array of fiber collimators. Adaptive optics compensation of turbulence-induced phase aberrations in these systems is performed at each fiber collimator. Our analysis is based on a derived expression for the atmospheric-averaged value of the mean square residual phase error as well as direct numerical simulations. Operation of both conformal-beam projection systems is compared for various adaptive system configurations characterized by the number of fiber collimators, the adaptive compensation resolution, and atmospheric turbulence conditions.

  18. Automated image quality evaluation of T2 -weighted liver MRI utilizing deep learning architecture.

    PubMed

    Esses, Steven J; Lu, Xiaoguang; Zhao, Tiejun; Shanbhogue, Krishna; Dane, Bari; Bruno, Mary; Chandarana, Hersh

    2018-03-01

    To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T 2 -weighted (T 2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T 2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T 2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T 2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T 2 WI of the liver. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Method of Implementing Digital Phase-Locked Loops

    NASA Technical Reports Server (NTRS)

    Stephens, Scott A. (Inventor); Thomas, J. Brooks (Inventor)

    1997-01-01

    In a new formulation for digital phase-locked loops, loop-filter constants are determined from loop roots that can each be selectively placed in the s-plane on the basis of a new set of parameters, each with simple and direct physical meaning in terms of loop noise bandwidth, root-specific decay rate, and root-specific damping. Loops of first to fourth order are treated in the continuous-update approximation (B(sub L)T approaches 0) and in a discrete-update formulation with arbitrary B(sub L)T. Deficiencies of the continuous-update approximation in large-B(sub L)T applications are avoided in the new discrete-update formulation.

  20. 49 CFR 236.766 - Locking, movable bridge.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  1. 49 CFR 236.766 - Locking, movable bridge.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  2. An online open-source tool for automated quantification of liver and myocardial iron concentrations by T2* magnetic resonance imaging.

    PubMed

    Git, K-A; Fioravante, L A B; Fernandes, J L

    2015-09-01

    To assess whether an online open-source tool would provide accurate calculations of T2(*) values for iron concentrations in the liver and heart compared with a standard reference software. An online open-source tool, written in pure HTML5/Javascript, was tested in 50 patients (age 26.0 ± 18.9 years, 46% males) who underwent T2(*) MRI of the liver and heart for iron overload assessment as part of their routine workup. Automated truncation correction was the default with optional manual adjustment provided if needed. The results were compared against a standard reference measurement using commercial software with manual truncation (CVI(42)(®) v. 5.1; Circle Cardiovascular Imaging; Calgary, AB). The mean liver T2(*) values calculated with the automated tool was 4.3 ms [95% confidence interval (CI) 3.1 to 5.5 ms] vs 4.26 ms using the reference software (95% CI 3.1 to 5.4 ms) without any significant differences (p = 0.71). In the liver, the mean difference was 0.036 ms (95% CI -0.1609 to 0.2329 ms) with a regression correlation coefficient of 0.97. For the heart, the automated T2(*) value was 26.0 ms (95% CI 22.9 to 29.0 ms) vs 25.3 ms (95% CI 22.3 to 28.3 ms), p = 0.28. The mean difference was 0.72 ms (95% CI 0.08191 to 1.3621 ms) with a correlation coefficient of 0.96. The automated online tool provides similar T2(*) values for the liver and myocardial iron concentrations as compared with a standard reference software. The online program provides an open-source tool for the calculation of T2(*) values, incorporating an automated correction algorithm in a simple and easy-to-use interface.

  3. Mode-locking observation of a CO2 laser by intracavity plasma injection

    NASA Astrophysics Data System (ADS)

    John, P. K.; Dembinski, M.

    1980-06-01

    A TEA CO2 laser was simultaneously Q-switched and mode-locked when an underdense plasma was injected into the cavity. The plasma was produced in an electromagnetic shock tube. Plasma density and temperature were N sub e of approximately 10 to the 17th/cu cm and T sub e of approximately 2 eV, respectively. Phase perturbation of the cavity due to the time dependent plasma refractive index could account for the observed mode-locking.

  4. Automated Ground Umbilical Systems (AGUS) Project

    NASA Technical Reports Server (NTRS)

    Gosselin, Armand M.

    2007-01-01

    All space vehicles require ground umbilical systems for servicing. Servicing requirements can include, but are not limited to, electrical power and control, propellant loading and venting, pneumatic system supply, hazard gas detection and purging as well as systems checkout capabilities. Of the various types of umbilicals, all require several common subsystems. These typically include an alignment system, mating and locking system, fluid connectors, electrical connectors and control !checkout systems. These systems have been designed to various levels of detail based on the needs for manual and/or automation requirements. The Automated Ground Umbilical Systems (AGUS) project is a multi-phase initiative to develop design performance requirements and concepts for launch system umbilicals. The automation aspect minimizes operational time and labor in ground umbilical processing while maintaining reliability. This current phase of the project reviews the design, development, testing and operations of ground umbilicals built for the Saturn, Shuttle, X-33 and Atlas V programs. Based on the design and operations lessons learned from these systems, umbilicals can be optimized for specific applications. The product of this study is a document containing details of existing systems and requirements for future automated umbilical systems with emphasis on design-for-operations (DFO).

  5. Electronic sideband locking of a broadly tunable 318.6 nm ultraviolet laser to an ultra-stable optical cavity

    NASA Astrophysics Data System (ADS)

    Bai, Jiandong; Wang, Jieying; He, Jun; Wang, Junmin

    2017-04-01

    We demonstrate frequency stabilization of a tunable 318.6 nm ultraviolet (UV) laser system using electronic sideband locking. By indirectly changing the frequency of a broadband electro-optic phase modulator, the laser can be continuously tuned over 4 GHz, while a 637.2 nm laser is directly stabilized to a high-finesse ultra-stable optical cavity. The doubling cavity also remains locked to the 637.2 nm light. We show that the tuning range depends mainly on the gain-flattening region of the modulator and the piezo-tunable range of the seed laser. The frequency-stabilized tunable UV laser system is able to compensate for the offset between reference and target frequencies, and has potential applications in precision spectroscopy of cold atoms.

  6. Heterodyne interferometry method for calibration of a Soleil-Babinet compensator.

    PubMed

    Zhang, Wenjing; Zhang, Zhiwei

    2016-05-20

    A method based on the common-path heterodyne interferometer system is proposed for the calibration of a Soleil-Babinet compensator. In this heterodyne interferometer system, which consists of two acousto-optic modulators, the compensator being calibrated is inserted into the signal path. By using the reference beam as the benchmark and a lock-in amplifier (SR844) as the phase retardation collector, retardations of 0 and λ (one wavelength) can be located accurately, and an arbitrary retardation between 0 and λ can also be measured accurately and continuously. By fitting a straight line to the experimental data, we obtained a linear correlation coefficient (R) of 0.995, which indicates that this system is capable of linear phase detection. The experimental results demonstrate determination accuracies of 0.212° and 0.26° and measurement precisions of 0.054° and 0.608° for retardations of 0 and λ, respectively.

  7. A magnetorheological fluid locking device

    NASA Astrophysics Data System (ADS)

    Kavlicoglu, Barkan; Liu, Yanming

    2011-04-01

    A magnetorheological fluid (MRF) device is designed to provide a static locking force caused by the operation of a controllable MRF valve. The intent is to introduce an MRF device which provides the locking force of a fifth wheel coupler while maintaining the "powerless" locking capability when required. A passive magnetic field supplied by a permanent magnet provides a powerless locking resistance force. The passively closed MRF valve provides sufficient reaction force to eliminate axial displacement to a pre-defined force value. Unlocking of the device is provided by means of an electromagnet which re-routes the magnetic field distribution along the MR valve, and minimizes the resistance. Three dimensional electromagnetic finite element analyses are performed to optimize the MRF lock valve performance. The MRF locking valve is fabricated and tested for installation on a truck fifth wheel application. An experimental setup, resembling actual working conditions, is designed and tests are conducted on vehicle interface schemes. The powerless-locking capacity and the unlocking process with minimal resistance are experimentally demonstrated.

  8. Homodyne locking of a squeezer.

    PubMed

    Heurs, M; Petersen, I R; James, M R; Huntington, E H

    2009-08-15

    We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.

  9. Cladding-pumped passively mode-locked fiber laser generating femtosecond and picosecond pulses

    NASA Astrophysics Data System (ADS)

    Fermann, M. E.; Harter, D.; Minelly, J. D.; Vienne, G. G.

    1996-07-01

    Passively mode-locked fiber lasers cladding pumped by broad-area diode-laser arrays are described. With a dispersion-compenstated erbium-ytterbium fiber oscillator, 200-fs pulses with pulse energies up to 100 pJ are generated at a wavelength of 1560 nm. In a highly dispersive cavity, pulse widths of 3 ps with pulse energies up to 1 nJ are obtained. A saturable absorber is used for pulse startup, whereas nonlinear polarization evolution is exploited for steady-state pulse shaping. An environmentally stable design is ensured by use of a compensation scheme for linear polarization drifts in the cavity.

  10. Cladding-pumped passively mode-locked fiber laser generating femtosecond and picosecond pulses.

    PubMed

    Fermann, M E; Harter, D; Minelly, J D; Vienne, G G

    1996-07-01

    Passively mode-locked fiber lasers cladding pumped by broad-area diode-laser arrays are described. With a dispersion-compenstated erbium-ytterbium fiber oscillator, 200-fs pulses with pulse energies up to 100 pJ are generated at a wavelength of 1560 nm. In a highly dispersive cavity, pulse widths of 3 ps with pulse energies up to 1 nJ are obtained. A saturable absorber is used for pulse startup, whereas nonlinear polarization evolution is exploited for steady-state pulse shaping. An environmentally stable design is ensured by use of a compensation scheme for linear polarization drifts in the cavity.

  11. 49 CFR 236.765 - Locking, mechanical.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  12. A component compensation method for magnetic interferential field

    NASA Astrophysics Data System (ADS)

    Zhang, Qi; Wan, Chengbiao; Pan, Mengchun; Liu, Zhongyan; Sun, Xiaoyong

    2017-04-01

    A new component searching with scalar restriction method (CSSRM) is proposed for magnetometer to compensate magnetic interferential field caused by ferromagnetic material of platform and improve measurement performance. In CSSRM, the objection function for parameter estimation is to minimize magnetic field (components and magnitude) difference between its measurement value and reference value. Two scalar compensation method is compared with CSSRM and the simulation results indicate that CSSRM can estimate all interferential parameters and external magnetic field vector with high accuracy. The magnetic field magnitude and components, compensated with CSSRM, coincide with true value very well. Experiment is carried out for a tri-axial fluxgate magnetometer, mounted in a measurement system with inertial sensors together. After compensation, error standard deviation of both magnetic field components and magnitude are reduced from more than thousands nT to less than 20 nT. It suggests that CSSRM provides an effective way to improve performance of magnetic interferential field compensation.

  13. Switching between the mode-locking and Q-switching modes in two-section QW lasers upon a change in the absorber properties due to the Stark effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gadzhiyev, I. M., E-mail: idris.intop@mail.ru; Buyalo, M. S.; Gubenko, A. E.

    2016-06-15

    The passive Q-switching and mode-locking modes are implemented in two-section lasers with three quantum wells. It is demonstrated that raising the reverse bias on the absorbing section changes its spectral and dynamic properties and, accordingly, leads to a change from the Q-switching mode to mode-locking. The pulse-repetition frequency in the mode-locking mode is 75 GHz, with the product of the pulse duration by the spectrum bandwidth being 0.49, which is close to the theoretical limit. It is shown that, in structures with three quantum wells, strong absorption at the lasing wavelength gives rise to a photocurrent across a section ofmore » the saturable absorber, which is sufficient for compensation of the applied bias.« less

  14. SU-E-T-04: 3D Dose Based Patient Compensator QA Procedure for Proton Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, W; Reyhan, M; Zhang, M

    2015-06-15

    Purpose: In proton double-scattering radiotherapy, compensators are the essential patient specific devices to contour the distal dose distribution to the tumor target. Traditional compensator QA is limited to checking the drilled surface profiles against the plan. In our work, a compensator QA process was established that assess the entire compensator including its internal structure for patient 3D dose verification. Methods: The fabricated patient compensators were CT scanned. Through mathematical image processing and geometric transformations, the CT images of the proton compensator were combined with the patient simulation CT images into a new series of CT images, in which the imagedmore » compensator is placed at the planned location along the corresponding beam line. The new CT images were input into the Eclipse treatment planning system. The original plan was calculated to the combined CT image series without the plan compensator. The newly computed patient 3D dose from the combined patientcompensator images was verified against the original plan dose. Test plans include the compensators with defects intentionally created inside the fabricated compensators. Results: The calculated 3D dose with the combined compensator and patient CT images reflects the impact of the fabricated compensator to the patient. For the test cases in which no defects were created, the dose distributions were in agreement between our method and the corresponding original plans. For the compensator with the defects, the purposely changed material and a purposely created internal defect were successfully detected while not possible with just the traditional compensator profiles detection methods. Conclusion: We present here a 3D dose verification process to qualify the fabricated proton double-scattering compensator. Such compensator detection process assesses the patient 3D impact of the fabricated compensator surface profile as well as the compensator internal material and structure

  15. Comparative Study of Drift Compensation Methods for Environmental Gas Sensors

    NASA Astrophysics Data System (ADS)

    Abidin, M. Z.; Asmat, Arnis; Hamidon, M. N.

    2018-02-01

    Most drift compensation attempts in environmental gas sensors are only emphasize on the “already-known” drift-causing parameter (i.e., ambient temperature, relative humidity) in compensating the sensor drift. Less consideration is taken to another parameter (i.e., baseline responses) that might have affected indirectly with the promotion of drift-causing parameter variable (in this context, is ambient temperature variable). In this study, the “indirect” drift-causing parameter (drifted baseline responses) has been taken into consideration in compensating the sensor drift caused by ambient temperature variable, by means of a proposed drift compensation method (named as RT-method). The effectiveness of this method in its efficacy of compensating drift was analysed and compared with the common method that used the “already-known” drift-causing parameter (named as T-method), using drift reduction percentage. From the results analysis, the RT-method has outperformed T- method in the drift reduction percentage, with its ability to reduce drift up to 64% rather than the T-method which only able to reduce up to 45% for TGS2600 sensor. It has proven that the inclusion of drifted baseline responses into drift compensation attempt would resulted to an improved drift compensation efficiency.

  16. Coal feed lock

    DOEpatents

    Pinkel, I. Irving

    1978-01-01

    A coal feed lock is provided for dispensing coal to a high pressure gas producer with nominal loss of high pressure gas. The coal feed lock comprises a rotor member with a diametral bore therethrough. A hydraulically activated piston is slidably mounted in the bore. With the feed lock in a charging position, coal is delivered to the bore and then the rotor member is rotated to a discharging position so as to communicate with the gas producer. The piston pushes the coal into the gas producer. The rotor member is then rotated to the charging position to receive the next load of coal.

  17. A simple method for astigmatic compensation of folded resonator without Brewster window.

    PubMed

    Qiao, Wen; Xiaojun, Zhang; Yonggang, Wang; Liqun, Sun; Hanben, Niu

    2014-02-10

    A folded resonator requires an oblique angle of incidence on the folded curved mirror, which introduces astigmatic distortions that limit the performance of the lasers. We present a simple method to compensate the astigmatism of folded resonator without Brewster windows for the first time to the best of our knowledge. Based on the theory of the propagation and transformation of Gaussian beams, the method is both effective and reliable. Theoretical results show that the folded resonator can be compensated astigmatism completely when the following two conditions are fulfilled. Firstly, when the Gaussian beam with a determined size beam waist is obliquely incident on an off-axis concave mirror, two new Gaussian beam respectively in the tangential and sagittal planes are formed. Another off-axis concave mirror is located at another intersection point of the two new Gaussian beams. Secondly, adjusting the incident angle of the second concave mirror or its focal length can make the above two Gaussian beam coincide in the image plane of the second concave mirror, which compensates the astigmatic aberration completely. A side-pumped continues-wave (CW) passively mode locked Nd:YAG laser was taken as an example of the astigmatically compensated folded resonators. The experimental results show good agreement with the theoretical predictions. This method can be used effectively to design astigmatically compensated cavities resonator of high-performance lasers.

  18. Automated segmentation of multifocal basal ganglia T2*-weighted MRI hypointensities

    PubMed Central

    Glatz, Andreas; Bastin, Mark E.; Kiker, Alexander J.; Deary, Ian J.; Wardlaw, Joanna M.; Valdés Hernández, Maria C.

    2015-01-01

    Multifocal basal ganglia T2*-weighted (T2*w) hypointensities, which are believed to arise mainly from vascular mineralization, were recently proposed as a novel MRI biomarker for small vessel disease and ageing. These T2*w hypointensities are typically segmented semi-automatically, which is time consuming, associated with a high intra-rater variability and low inter-rater agreement. To address these limitations, we developed a fully automated, unsupervised segmentation method for basal ganglia T2*w hypointensities. This method requires conventional, co-registered T2*w and T1-weighted (T1w) volumes, as well as region-of-interest (ROI) masks for the basal ganglia and adjacent internal capsule generated automatically from T1w MRI. The basal ganglia T2*w hypointensities were then segmented with thresholds derived with an adaptive outlier detection method from respective bivariate T2*w/T1w intensity distributions in each ROI. Artefacts were reduced by filtering connected components in the initial masks based on their standardised T2*w intensity variance. The segmentation method was validated using a custom-built phantom containing mineral deposit models, i.e. gel beads doped with 3 different contrast agents in 7 different concentrations, as well as with MRI data from 98 community-dwelling older subjects in their seventies with a wide range of basal ganglia T2*w hypointensities. The method produced basal ganglia T2*w hypointensity masks that were in substantial volumetric and spatial agreement with those generated by an experienced rater (Jaccard index = 0.62 ± 0.40). These promising results suggest that this method may have use in automatic segmentation of basal ganglia T2*w hypointensities in studies of small vessel disease and ageing. PMID:25451469

  19. SU-F-T-372: Surface and Peripheral Dose in Compensator-Based FFF Beam IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D; Feygelman, V; Moros, E

    2016-06-15

    Purpose: Flattening filter free (FFF) beams produce higher dose rates. Combined with compensator IMRT techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or compensator-based IMRT. This ‘snap shot’ IMRT delivery is beneficial to patients for tumor motion management. Due to softer energy, surface doses in FFF beam treatment are usually higher than those from flattened beams. Because of less scattering due to no flattening filter, peripheral doses are usually lower in FFF beam treatment. However, in compensator-based IMRT using FFF beams, the compensator is in the beam pathway. Does it introducemore » beam hardening effects and scattering such that the surface dose is lower and peripheral dose is higher compared to FFF beam MLC-based IMRT? Methods: This study applied Monte Carlo techniques to investigate the surface and peripheral doses in compensator-based IMRT using FFF beams and compared it to the MLC-based IMRT using FFF beams and flattened beams. Besides various thicknesses of copper slabs to simulate various thicknesses of compensators, a simple cone-shaped compensator was simulated to mimic a clinical application. The dose distribution in water phantom by the cone-shaped compensator was then simulated by multiple MLC defined FFF and flattened beams with various openings. After normalized to Dmax, the surface and peripheral dose was compared between the FFF beam compensator-based IMRT and FFF/flattened beam MLC-based IMRT. Results: The surface dose at the central 0.5mm depth was close between the compensator and 6FFF MLC dose distributions, and about 8% (of Dmax) higher than the flattened 6MV MLC dose. At 8cm off axis at dmax, the peripheral dose between the 6FFF and flattened 6MV MLC demonstrated similar doses, while the compensator dose was about 1% higher. Conclusion: Compensator does not reduce the surface doses but slightly increases the peripheral doses due to scatter inside compensator.« less

  20. 2.4-3.2 GHz robust self-injecting injection-locked phase-locked loop

    NASA Astrophysics Data System (ADS)

    Yang, Jincheng; Zhang, Zhao; Qi, Nan; Liu, Liyuan; Liu, Jian; Wu, Nanjian

    2018-04-01

    In this paper, we propose a robust self-injecting injection-locked phase-locked loop (SI-ILPLL). It adopts a phase alignment loop (PAL) based on a subsampling phase frequency detector to align the phase between the injected pulse and the voltage-controlled oscillator (VCO) output. With the proposed phase frequency detector, the PAL performs phase alignment and the pulse generator can self-inject pulses into the VCO for injection locking. The subsampling phase detection and self-injection locking techniques can suppress the phase noise of the SI-ILPLL. The SI-ILPLL shows excellent robustness to environmental interference. The SI-ILPLL is implemented in 65 nm CMOS technology. It occupies an active area of 0.7 mm2. The measured root-mean-square (RMS) jitters at 3.2 GHz output without and with injection locking are 216 and 131 fs, respectively. When the supply voltage varies from 1.17 to 1.23 V and the temperature varies from 0 to 80 °C, the maximum jitter variation of all the output frequencies is less than 50 fs. The measured results demonstrate that even when a large interference appears at the supply voltage and unlocks the SI-ILPLL, the SI-ILPLL can self-recover its injection-locked state rapidly after the disturbance disappears, whereas the conventional ILPLL cannot self-recover its locked state after losing it. The power consumption of the SI-ILPLL is 7.4 mW under a 1.2 V supply voltage. The SI-ILPLL achieves a figure of merit (FOM) of -249 dB.

  1. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.

    PubMed

    Kandemir, Utku; Herfat, Safa; Herzog, Mary; Viscogliosi, Paul; Pekmezci, Murat

    2017-02-01

    The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures. Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures. DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure. For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.

  2. Relationship Between Locked Modes and Disruptions in the DIII-D Tokamak

    NASA Astrophysics Data System (ADS)

    Sweeney, Ryan

    This thesis is organized into three body chapters: (1) the first use of naturally rotating tearing modes to diagnose intrinsic error fields is presented with experimental results from the EXTRAP T2R reversed field pinch, (2) a large scale study of locked modes (LMs) with rotating precursors in the DIII-D tokamak is reported, and (3) an in depth study of LM induced thermal collapses on a few DIII-D discharges is presented. The amplitude of naturally rotating tearing modes (TMs) in EXTRAP T2R is modulated in the presence of a resonant field (given by the superposition of the resonant intrinsic error field, and, possibly, an applied, resonant magnetic perturbation (RMP)). By scanning the amplitude and phase of the RMP and observing the phase-dependent amplitude modulation of the resonant, naturally rotating TM, the corresponding resonant error field is diagnosed. A rotating TM can decelerate and lock in the laboratory frame, under the effect of an electromagnetic torque due to eddy currents induced in the wall. These locked modes often lead to a disruption, where energy and particles are lost from the equilibrium configuration on a timescale of a few to tens of milliseconds in the DIII-D tokamak. In fusion reactors, disruptions pose a problem for the longevity of the reactor. Thus, learning to predict and avoid them is important. A database was developed consisting of ˜ 2000 DIII-D discharges exhibiting TMs that lock. The database was used to study the evolution, the nonlinear effects on equilibria, and the disruptivity of locked and quasi-stationary modes with poloidal and toroidal mode numbers m = 2 and n = 1 at DIII-D. The analysis of 22,500 discharges shows that more than 18% of disruptions present signs of locked or quasi-stationary modes with rotating precursors. A parameter formulated by the plasma internal inductance li divided by the safety factor at 95% of the toroidal flux, q95, is found to exhibit predictive capability over whether a locked mode will

  3. Optical injection phase-lock loops

    NASA Astrophysics Data System (ADS)

    Bordonalli, Aldario Chrestani

    Locking techniques have been widely applied for frequency synchronisation of semiconductor lasers used in coherent communication and microwave signal generation systems. Two main locking techniques, the optical phase-lock loop (OPLL) and optical injection locking (OIL) are analysed in this thesis. The principal limitations on OPLL performance result from the loop propagation delay, which makes difficult the implementation of high gain and wide bandwidth loops, leading to poor phase noise suppression performance and requiring the linewidths of the semiconductor laser sources to be less than a few megahertz for practical values of loop delay. The OIL phase noise suppression is controlled by the injected power. The principal limitations of the OIL implementation are the finite phase error under locked conditions and the narrow stable locking range the system provides at injected power levels required to reduce the phase noise output of semiconductor lasers significantly. This thesis demonstrates theoretically and experimentally that it is possible to overcome the limitations of OPLL and OIL systems by combining them, to form an optical injection phase-lock loop (OIPLL). The modelling of an OIPLL system is presented and compared with the equivalent OPLL and OIL results. Optical and electrical design of an homodyne OIPLL is detailed. Experimental results are given which verify the theoretical prediction that the OIPLL would keep the phase noise suppression as high as that of the OIL system over a much wider stable locking range, even with wide linewidth lasers and long loop delays. The experimental results for lasers with summed linewidth of 36 MHz and a loop delay of 15 ns showed measured phase error variances as low as 0.006 rad2 (500 MHz bandwidth) for locking bandwidths greater than 26 GHz, compared with the equivalent OPLL phase error variance of around 1 rad2 (500 MHz bandwidth) and the equivalent OIL locking bandwidth of less than 1.2 GHz.

  4. Safe-haven locking device

    DOEpatents

    Williams, J.V.

    1984-04-26

    Disclosed is a locking device for eliminating external control of a secured space formed by fixed and movable barriers. The locking device uses externally and internally controlled locksets and a movable strike, operable from the secured side of the movable barrier, to selectively engage either lockset. A disengagement device, for preventing forces from being applied to the lock bolts is also disclosed. In this manner, a secured space can be controlled from the secured side as a safe-haven. 4 figures.

  5. Passive Optical Locking Techniques for Diode Lasers

    NASA Astrophysics Data System (ADS)

    Zhang, Quan

    1995-01-01

    Most current diode-based nonlinear frequency converters utilize electronic frequency locking techniques. However, this type of locking technique typically involves very complex electronics, and suffers the 'power-drop' problem. This dissertation is devoted to the development of an all-optical passive locking technique that locks the diode laser frequency to the external cavity resonance stably without using any kind of electronic servo. The amplitude noise problem associated with the strong optical locking has been studied. Single-mode operation of a passively locked single-stripe diode with an amplitude stability better than 1% has been achieved. This passive optical locking technique applies to broad-area diodes as well as single-stripe diodes, and can be easily used to generate blue light. A schematic of a milliwatt level blue laser based on the single-stripe diode locking technique has been proposed. A 120 mW 467 nm blue laser has been built using the tapered amplifier locking technique. In addition to diode-based blue lasers, this passive locking technique has applications in nonlinear frequency conversions, resonant spectroscopy, particle counter devices, telecommunications, and medical devices.

  6. Phase-locked Optical Signal Recovery

    DTIC Science & Technology

    2009-01-01

    detection . However, implementing an optical phase lock loop ( OPLL ) to generate the synchronised carrier for the homodyne technique requires... Loop (OIPLL) in which a narrow bandwidth optical phase lock loop ( OPLL ) is used to control the free -running frequency of an optically injection...receiver uses an Optical Injection Phase Lock Loop (OIPLL) for carrier recovery,

  7. Phase-locked Optical Signal Recovery

    DTIC Science & Technology

    2009-01-01

    detection . However, implementing an optical phase lock loop ( OPLL ) to generate the synchronised carrier for the homodyne technique requires... Loop (OIPLL) in which a narrow bandwidth optical phase lock loop ( OPLL ) is used to control the free -running frequency of an optically injection...The receiver uses an Optical Injection Phase Lock Loop (OIPLL) for carrier

  8. Morbus-Locke's early essay on disease.

    PubMed

    Walmsley, J

    2000-01-01

    John Locke engaged in a systematic study of medicine from the late 1650's. In this period he acquainted himself with the three main competing natural philosophical theories of the time -Galenism, Paracelsianism and Mechanism. He was particularly interested in the work of Sennert, Helmont and Doyle. In 1666, just after the publication of Boyle's The Origine of Formes and Qualities, Locke wrote a short paper entitled Morbus. This paper gave Locke's own view of the nature of disease. Locke went out of his way to criticise Boyle's attempts to give mechanical explanations for biological phenomena. He endorsed Helmont's theory that disease was caused by "ferments" and "Archei" and re-introduced Galenic temperaments as factors of susceptibility in seminal diseases. Locke did not endorse a mechanical corpuscularianism at this stage in his career, when his contact with Boyle was most frequent. Consequently, Locke's espousal of the corpuscular philosophy in the Essay cannot be attributed to Locke's association with Boyle at this time.

  9. 76 FR 48840 - Lock+TM

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-09

    ... Lock and Dam No. 5; (2) a 109-foot- wide, 40-foot-high lock frame module placed east of the movable... the grid. Each lock frame module would consist of ten 7-foot-diameter hydropower turbines each rated... the powerhouse on the east section of the dam in the existing levee of the east abutment; (2) a...

  10. In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer.

    PubMed

    Fang, Jiancheng; Qin, Jie

    2012-10-01

    The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

  11. 46 CFR 154.345 - Air locks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Air locks. 154.345 Section 154.345 Shipping COAST GUARD....345 Air locks. (a) An air lock may be used for access from a gas-dangerous zone on the weather deck to a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  12. 46 CFR 154.345 - Air locks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Air locks. 154.345 Section 154.345 Shipping COAST GUARD....345 Air locks. (a) An air lock may be used for access from a gas-dangerous zone on the weather deck to a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  13. 46 CFR 154.345 - Air locks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Air locks. 154.345 Section 154.345 Shipping COAST GUARD....345 Air locks. (a) An air lock may be used for access from a gas-dangerous zone on the weather deck to a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  14. 46 CFR 154.345 - Air locks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Air locks. 154.345 Section 154.345 Shipping COAST GUARD....345 Air locks. (a) An air lock may be used for access from a gas-dangerous zone on the weather deck to a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  15. 46 CFR 154.345 - Air locks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Air locks. 154.345 Section 154.345 Shipping COAST GUARD....345 Air locks. (a) An air lock may be used for access from a gas-dangerous zone on the weather deck to a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  16. Blind-Side, High-Temperature Fastener Lock

    NASA Technical Reports Server (NTRS)

    Matza, E. C.; While, D. M.

    1985-01-01

    Formed-in-place staple provides positive mechanical lock. Post-supported, advanced carbon/carbon standoff panels, currently under consideration as alternate thermal protection system for Shuttle orbiter, locking feature applicable to temperatures of 1,600 degrees F (870 degrees C) and higher and employable after panel installed, resulting in blind application. Blind-side locking technique employs wire staple inserted into grooves in post, formed in place by ramped portion of post grooves. This splays out wire ends that move into castellated end of grommet, mechanically locking post and grommet against relative rotation. Splayed ends provide mechanical lock to prevent wire from falling out.

  17. Precision and broadband frequency swept laser source based on high-order modulation-sideband injection-locking.

    PubMed

    Wei, Fang; Lu, Bin; Wang, Jian; Xu, Dan; Pan, Zhengqing; Chen, Dijun; Cai, Haiwen; Qu, Ronghui

    2015-02-23

    A precision and broadband laser frequency swept technique is experimentally demonstrated. Using synchronous current compensation, a slave diode laser is dynamically injection-locked to a specific high-order modulation-sideband of a narrow-linewidth master laser modulated by an electro-optic modulator (EOM), whose driven radio frequency (RF) signal can be agilely, precisely controlled by a frequency synthesizer, and the high-order modulation-sideband enables multiplied sweep range and tuning rate. By using 5th order sideband injection-locking, the original tuning range of 3 GHz and tuning rate of 0.5 THz/s is multiplied by 5 times to 15 GHz and 2.5 THz/s respectively. The slave laser has a 3 dB-linewidth of 2.5 kHz which is the same to the master laser. The settling time response of a 10 MHz frequency switching is 2.5 µs. By using higher-order modulation-sideband and optimized experiment parameters, an extended sweep range and rate could be expected.

  18. PWR integral tie plate and locking mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flora, B.S.; Osborne, J.L.

    1980-08-26

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to themore » assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle.« less

  19. Controls on the Climates of Tidally Locked Terrestrial Planets

    NASA Astrophysics Data System (ADS)

    Yang, J.; Cowan, N. B.; Abbot, D. S.

    2013-12-01

    (OET) is included, although the compensation between AET and OET is incomplete. To summarize, we are able to construct a realistic low-order model for the climate of tidally locked terrestrial planets, including the cloud behavior, using only the two constraints. This bodes well for the interpretation of complex GCMs and future observations of such planets using, for example, the James Webb Space Telescope. Cited papers: [1]. Sobel, A. H., J. Nilsson and L. M. Polvani: The weak temperature gradient approximation and balanced tropical moisture waves, J. Atmos. Sci., 58, 3650-65, 2001. [2]. Hartmann, D. L. and K. Larson, An important constraint on tropical cloud-climate feedback, Geophys. Res. Lett., 29, 1951-54, 2002. [3]. Yang, J., N. B. Cowan and D. S. Abbot: Stabilizing cloud feedback dramatically expands the habitable zone of tidally locked planets, ApJ. Lett., 771, L45, 2013.

  20. Mathematical simulation for compensation capacities area of pipeline routes in ship systems

    NASA Astrophysics Data System (ADS)

    Ngo, G. V.; Sakhno, K. N.

    2018-05-01

    In this paper, the authors considered the problem of manufacturability’s enhancement of ship systems pipeline at the designing stage. The analysis of arrangements and possibilities for compensation of deviations for pipeline routes has been carried out. The task was set to produce the “fit pipe” together with the rest of the pipes in the route. It was proposed to compensate for deviations by movement of the pipeline route during pipe installation and to calculate maximum values of these displacements in the analyzed path. Theoretical bases of deviation compensation for pipeline routes using rotations of parallel section pairs of pipes are assembled. Mathematical and graphical simulations of compensation area capacities of pipeline routes with various configurations are completed. Prerequisites have been created for creating an automated program that will allow one to determine values of the compensatory capacities area for pipeline routes and to assign quantities of necessary allowances.

  1. Delay compensation in integrated communication and control systems. I - Conceptual development and analysis

    NASA Technical Reports Server (NTRS)

    Luck, Rogelio; Ray, Asok

    1990-01-01

    A procedure for compensating for the effects of distributed network-induced delays in integrated communication and control systems (ICCS) is proposed. The problem of analyzing systems with time-varying and possibly stochastic delays could be circumvented by use of a deterministic observer which is designed to perform under certain restrictive but realistic assumptions. The proposed delay-compensation algorithm is based on a deterministic state estimator and a linear state-variable-feedback control law. The deterministic observer can be replaced by a stochastic observer without any structural modifications of the delay compensation algorithm. However, if a feedforward-feedback control law is chosen instead of the state-variable feedback control law, the observer must be modified as a conventional nondelayed system would be. Under these circumstances, the delay compensation algorithm would be accordingly changed. The separation principle of the classical Luenberger observer holds true for the proposed delay compensator. The algorithm is suitable for ICCS in advanced aircraft, spacecraft, manufacturing automation, and chemical process applications.

  2. Rational harmonic mode-locking pulse quality of the dark-optical-comb injected semiconductor optical amplifier fiber ring laser.

    PubMed

    Lin, Gong-Ru; Lee, Chao-Kuei; Kang, Jung-Jui

    2008-06-09

    We study the rational harmonic mode-locking (RHML) order dependent pulse shortening force and dynamic chirp characteristics of a gain-saturated semiconductor optical amplifier fiber laser (SOAFL) under dark-optical-comb injection, and discuss the competition between mode-locking mechanisms in the SOAFL at high-gain and strong optical injection condition at higher RHML orders. The evolutions of spectra, mode-locking and continuous lasing powers by measuring the ratio of DC/pulse amplitude and the pulse shortening force (I(pulse)/P(avg)(2) ) are performed to determine the RHML capability of SOAFL. As the rational harmonic order increases up to 20, the spectral linewidth shrinks from 12 to 3 nm, the ratio of DC/pulse amplitude enlarges from 0.025 to 2.4, and the pulse-shortening force reduces from 0.9 to 0.05. At fundamental and highest RHML condition, we characterize the frequency detuning range to realize the mode-locking quality, and measure the dynamic frequency chirp of the RHML-SOAFL to distinguish the linear and nonlinear chirp after dispersion compensation. With increasing RHML order, the pulsewidth is broadened from 4.2 to 26.4 ps with corresponding chirp reducing from 0.7 to 0.2 GHz and linear/nonlinear chirp ratio changes from 4.3 to 1.3, which interprets the high-order chirp becomes dominates at higher RHML orders.

  3. 27 CFR 19.282 - Breaking Government locks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Breaking Government locks... Breaking Government locks. Where affixed, Government locks shall not be removed without the authorization... obtain authorization from an appropriate TTB officer, Government locks may be removed, by the proprietor...

  4. 49 CFR 236.376 - Mechanical locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Mechanical locking. 236.376 Section 236.376 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... and Tests § 236.376 Mechanical locking. Mechanical locking in interlocking machine shall be tested...

  5. 49 CFR 236.761 - Locking, electric.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  6. 49 CFR 236.761 - Locking, electric.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  7. 49 CFR 236.105 - Electric lock.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  8. 49 CFR 236.105 - Electric lock.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  9. 49 CFR 236.761 - Locking, electric.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  10. 49 CFR 236.761 - Locking, electric.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  11. 49 CFR 236.761 - Locking, electric.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  12. 49 CFR 236.105 - Electric lock.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  13. 49 CFR 236.105 - Electric lock.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  14. 49 CFR 236.105 - Electric lock.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  15. 49 CFR 236.762 - Locking, indication.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, indication. 236.762 Section 236.762 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, indication. Electric locking which prevents manipulation of levers that would result in an unsafe...

  16. 49 CFR 236.760 - Locking, approach.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, approach. 236.760 Section 236.760 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, approach. Electric locking effective while a train is approaching, within a specified distance, a...

  17. 49 CFR 236.769 - Locking, traffic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, traffic. 236.769 Section 236.769 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, traffic. Electric locking which prevents the manipulation of levers or other devices for changing...

  18. Active phase locking of thirty fiber channels using multilevel phase dithering method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhimeng; Luo, Yongquan, E-mail: yongquan-l@sina.com; Liu, Cangli

    2016-03-15

    An active phase locking of a large-scale fiber array with thirty channels has been demonstrated experimentally. In the experiment, the first group of thirty phase controllers is used to compensate the phase noises between the elements and the second group of thirty phase modulators is used to impose additional phase disturbances to mimic the phase noises in the high power fiber amplifiers. A multi-level phase dithering algorithm using dual-level rectangular-wave phase modulation and time division multiplexing can achieve the same phase control as single/multi-frequency dithering technique, but without coherent demodulation circuit. The phase locking efficiency of 30 fiber channels ismore » achieved about 98.68%, 97.82%, and 96.50% with no additional phase distortion, modulated phase distortion I (±1 rad), and phase distortion II (±2 rad), corresponding to the phase error of λ/54, λ/43, and λ/34 rms. The contrast of the coherent combined beam profile is about 89%. Experimental results reveal that the multi-level phase dithering technique has great potential in scaling to a large number of laser beams.« less

  19. Electronic door locking mechanism

    DOEpatents

    Williams, Gary Lin; Kirby, Patrick Gerald

    1997-01-01

    The invention is a motorized linkage for engaging a thumb piece in a door mechanism. The device has an exterior lock assembly with a small battery cell and combination lock. Proper entry by a user of a security code allows the battery to operate a small motor within the exterior lock assembly. The small motor manipulates a cam-plunger which moves an actuator pin into a thumb piece. The user applies a force on to the thumb piece. This force is transmitted by the thumb piece to a latch engagement mechanism by the actuator pin. The latch engagement mechanism operates the door latch.

  20. Locking support for nuclear fuel assemblies

    DOEpatents

    Ledin, Eric

    1980-01-01

    A locking device for supporting and locking a nuclear fuel assembly within a cylindrical bore formed by a support plate, the locking device including a support and locking sleeve having upwardly extending fingers forming wedge shaped contact portions arranged for interaction between an annular tapered surface on the fuel assembly and the support plate bore as well as downwardly extending fingers having wedge shaped contact portions arranged for interaction between an annularly tapered surface on the support plate bore and the fuel assembly whereby the sleeve tends to support and lock the fuel assembly in place within the bore by its own weight while facilitating removal and/or replacement of the fuel assembly.

  1. 49 CFR 236.378 - Time locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Time locking. 236.378 Section 236.378 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... and Tests § 236.378 Time locking. Time locking shall be tested when placed in service and thereafter...

  2. 49 CFR 236.378 - Time locking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Time locking. 236.378 Section 236.378 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... and Tests § 236.378 Time locking. Time locking shall be tested when placed in service and thereafter...

  3. 49 CFR 236.767 - Locking, route.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, route. 236.767 Section 236.767 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, route. Electric locking, effective when a train passes a signal displaying an aspect for it to...

  4. Towards Automated Nanomanipulation under Scanning Electron Microscopy

    NASA Astrophysics Data System (ADS)

    Ye, Xutao

    Robotic Nanomaterial Manipulation inside scanning electron microscopes (SEM) is useful for prototyping functional devices and characterizing one-dimensional nanomaterial's properties. Conventionally, manipulation of nanowires has been performed via teleoperation, which is time-consuming and highly skill-dependent. Manual manipulation also has the limitation of low success rates and poor reproducibility. This research focuses on a robotic system capable of automated pick-place of single nanowires. Through SEM visual detection and vision-based motion control, the system transferred individual silicon nanowires from their growth substrate to a microelectromechanical systems (MEMS) device that characterized the nanowires' electromechanical properties. The performances of the nanorobotic pick-up and placement procedures were quantified by experiments. The system demonstrated automated nanowire pick-up and placement with high reliability. A software system for a load-lock-compatible nanomanipulation system is also designed and developed in this research.

  5. Efficient optical injection locking of electronic oscillators

    NASA Astrophysics Data System (ADS)

    Cochran, S. R.; Wang, S. Y.

    1989-05-01

    The paper presents techniques for direct optical injection locking of electronic oscillators and analyzes the problem of direct optical injection locking of a common-source FET oscillator using a high impedance optoelectronic transducer. A figure-of-merit for optically injection locked oscillators is defined, and an experimental oscillator based on the design criteria was fabricated. The oscillator achieved efficient, high power operation and moderate locking bandwidth with small locking signal magnitude. The experimental results are consistent with the theoretical model.

  6. Simultaneous Measurement of T2 and Apparent Diffusion Coefficient (T2+ADC) in the Heart With Motion-Compensated Spin Echo Diffusion-Weighted Imaging

    PubMed Central

    Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.

    2018-01-01

    Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P < 0.01), and ADC values were in excellent agreement with DWI (0.28 ± 0.4%). In volunteers, myocardial T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P < 0.01); myocardial ADC was not significantly (N.S.) different between T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P < 0.01; ADC: 1.47 ± 0.59 vs 1.65 ± 0.65 mm2/ms; P < 0.01). Conclusion T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485

  7. Phase-locking dynamics in optoelectronic oscillator

    NASA Astrophysics Data System (ADS)

    Banerjee, Abhijit; Sarkar, Jayjeet; Das, NikhilRanjan; Biswas, Baidyanath

    2018-05-01

    This paper analyzes the phase-locking phenomenon in single-loop optoelectronic microwave oscillators considering weak and strong radio frequency (RF) signal injection. The analyses are made in terms of the lock-range, beat frequency and the spectral components of the unlocked-driven oscillator. The influence of RF injection signal on the frequency pulling of the unlocked-driven optoelectronic oscillator (OEO) is also studied. An approximate expression for the amplitude perturbation of the oscillator is derived and the influence of amplitude perturbation on the phase-locking dynamics is studied. It is shown that the analysis clearly reveals the phase-locking phenomenon and the associated frequency pulling mechanism starting from the fast-beat state through the quasi-locked state to the locked state of the pulled OEO. It is found that the unlocked-driven OEO output signal has a very non-symmetrical sideband distribution about the carrier. The simulation results are also given in partial support to the conclusions of the analysis.

  8. Magnetic Control of Locked Modes in Present Devices and ITER

    NASA Astrophysics Data System (ADS)

    Volpe, F. A.; Sabbagh, S.; Sweeney, R.; Hender, T.; Kirk, A.; La Haye, R. J.; Strait, E. J.; Ding, Y. H.; Rao, B.; Fietz, S.; Maraschek, M.; Frassinetti, L.; in, Y.; Jeon, Y.; Sakakihara, S.

    2014-10-01

    The toroidal phase of non-rotating (``locked'') neoclassical tearing modes was controlled in several devices by means of applied magnetic perturbations. Evidence is presented from various tokamaks (ASDEX Upgrade, DIII-D, JET, J-TEXT, KSTAR), spherical tori (MAST, NSTX) and a reversed field pinch (EXTRAP-T2R). Furthermore, the phase of interchange modes was controlled in the LHD helical device. These results share a common interpretation in terms of torques acting on the mode. Based on this interpretation, it is predicted that control-coil currents will be sufficient to control the phase of locking in ITER. This will be possible both with the internal coils and with the external error-field-correction coils, and might have promising consequences for disruption avoidance (by aiding the electron cyclotron current drive stabilization of locked modes), as well as for spatially distributing heat loads during disruptions. This work was supported in part by the US Department of Energy under DE-SC0008520, DE-FC-02-04ER54698 and DE-AC02-09CH11466.

  9. 1.2-ps mode-locked semiconductor optical amplifier fiber laser pulses generated by 60-ps backward dark-optical comb injection and soliton compression.

    PubMed

    Lin, Gong-Ru; Chiu, I-Hsiang; Wu, Ming-Chung

    2005-02-07

    Optically harmonic mode-locking of a semiconductor optical amplifier fiber laser (SOAFL) induced by backward injecting a dark-optical comb is demonstrated for the first time. The dark-optical comb with 60-ps pulsewidth is generated from a Mach-Zehnder modulator, which is driven by an electrical comb at a DC offset of 0.3Vn. Theoretical simulation indicates that the backward injection of dark-optical comb results in a narrow gain window of 60 ps within one modulating period, providing a cross-gainmodulation induced mode-locking in the SOAFL with a shortest pulsewidth of 15 ps at repetition frequency of 1 GHz. The mode-locked SOAFL pulsewidth can be slightly shortened to 10.8 ps with a 200m-long dispersion compensating fiber. After nonlinearly soliton compression in a 5km-long single mode fiber, the pulsewidth, linewidth and time-bandwidth product become 1.2 ps, 2.06 nm and 0.31, respectively.

  10. Opto-mechanical door locking system

    NASA Astrophysics Data System (ADS)

    Patil, Saurabh S.; Rodrigues, Vanessa M.; Patil, Ajeetkumar; Chidangil, Santhosh

    2015-09-01

    We present an Opto-mechanical Door Locking System which is an optical system that combines a simple combination of a coherent light source (Laser) and a photodiode based sensor with focus toward security applications. The basic construct of the KEY comprises a Laser source in a cylindrical enclosure that slides perfectly into the LOCK. The Laser is pulsed at a fixed encrypted frequency unique to that locking system. Transistor-transistor logic (TTL) circuitry is used to achieve encryption. The casing of the key is designed in such a way that it will power the pulsing laser only when the key is inserted in the slot provided for it. The Lock includes a photo-sensor that will convert the detected light intensity to a corresponding electrical signal by decrypting the frequency. The lock also consists of a circuit with a feedback system that will carry the digital information regarding the encryption frequency code. The information received from the sensor is matched with the stored code; if found a perfect match, a signal will be sent to the servo to unlock the mechanical lock or to carry out any other operation. This technique can be incorporated in security systems for residences and safe houses, and can easily replace all conventional locks which formerly used fixed patterns to unlock. The major advantage of this proposed optomechanical system over conventional ones is that it no longer relies on a solid/imprinted pattern to perform its task and hence makes it almost impossible to tamper with.

  11. 49 CFR 236.705 - Bar, locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Bar, locking. 236.705 Section 236.705..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.705 Bar, locking. A bar in an interlocking machine to which the locking dogs are attached. ...

  12. 49 CFR 236.768 - Locking, time.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  13. 49 CFR 236.768 - Locking, time.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  14. Self-locking degree-4 vertex origami structures

    PubMed Central

    Li, Suyi; Wang, K. W.

    2016-01-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications. PMID:27956889

  15. Self-locking degree-4 vertex origami structures.

    PubMed

    Fang, Hongbin; Li, Suyi; Wang, K W

    2016-11-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications.

  16. Electronic door locking mechanism

    DOEpatents

    Williams, G.L.; Kirby, P.G.

    1997-10-21

    The invention is a motorized linkage for engaging a thumb piece in a door mechanism. The device has an exterior lock assembly with a small battery cell and combination lock. Proper entry by a user of a security code allows the battery to operate a small motor within the exterior lock assembly. The small motor manipulates a cam-plunger which moves an actuator pin into a thumb piece. The user applies a force on to the thumb piece. This force is transmitted by the thumb piece to a latch engagement mechanism by the actuator pin. The latch engagement mechanism operates the door latch. 6 figs.

  17. Automatically Locking/Unlocking Orthotic Knee Joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1994-01-01

    Proposed orthotic knee joint locks and unlocks automatically, at any position within range of bend angles, without manual intervention by wearer. Includes tang and clevis, locks whenever wearer transfers weight to knee and unlocks when weight removed. Locking occurs at any angle between 45 degrees knee bend and full extension.

  18. Internal impacted screw-locking pellet

    NASA Technical Reports Server (NTRS)

    MacMartin, Malcolm J. (Inventor)

    1994-01-01

    An elongate fastener having an engaging surface engageable with an engaging surface of a fastener's mate includes a hole extending through a portion of the fastener and having a top opening and a bottom floor, a locking pellet disposed near the bottom floor, a discharge channel communicating between the pellet and through the engaging surface of the fastener and opening out toward the engaging surface of the fastener's mate, and an impact pin in the hole having a top portion protruding through the top opening and a bottom portion near the locking pellet, whereby the pin drives the locking pellet through the discharge channel against the engaging surfaces of the fastener and the fastener's mate whereby to lock the fastener against the fastener's mate.

  19. Optical double-locked semiconductor lasers

    NASA Astrophysics Data System (ADS)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  20. Lock-up control system for an automatic transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higashi, H.; Yashiki, S.; Waki, K.

    A lock-up control system is described for an automatic transmission including a torque converter coupled with the output portion on an engine, and a power transmitting gear arrangement coupled with the output portion of the torque converter and controlled to vary the transmitting gear ratio therein by gear ratio control means in accordance with a shifting up or down command supplied to the latter. A lock-up clutch is provided for locking up the output portion of the torque converter to the output portion of the engine. The lock-up control system comprises: lock-up operation control means for controlling the lock-up clutchmore » to be in its operative state and in its inoperative state selectively, and for causing the lock-up clutch to be in the inoperative state thereof when the gear ratio control means performs the control with the shifting up or down command, and lock-up command means for preventing the lock-up operation control means from causing the lock-up clutch to be in the inoperative state thereof until a predetermined reductive variation in the speed of the output portion of the torque converter arises after the shifting up command is supplied to the gear ratio control means under the condition in which the lock-up clutch is in operation to hold a lock-up state.« less

  1. 49 CFR 236.757 - Lock, electric.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  2. 49 CFR 236.757 - Lock, electric.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  3. 49 CFR 236.757 - Lock, electric.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  4. 49 CFR 236.757 - Lock, electric.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  5. 49 CFR 236.757 - Lock, electric.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  6. 46 CFR 108.157 - Locked doors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Locked doors. 108.157 Section 108.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT... may be designed to lock except— (a) A crash door or a door that has a locking device that can be...

  7. Clinical Laboratory Automation: A Case Study.

    PubMed

    Archetti, Claudia; Montanelli, Alessandro; Finazzi, Dario; Caimi, Luigi; Garrafa, Emirena

    2017-04-13

    This paper presents a case study of an automated clinical laboratory in a large urban academic teaching hospital in the North of Italy, the Spedali Civili in Brescia, where four laboratories were merged in a unique laboratory through the introduction of laboratory automation. The analysis compares the preautomation situation and the new setting from a cost perspective, by considering direct and indirect costs. It also presents an analysis of the turnaround time (TAT). The study considers equipment, staff and indirect costs. The introduction of automation led to a slight increase in equipment costs which is highly compensated by a remarkable decrease in staff costs. Consequently, total costs decreased by 12.55%. The analysis of the TAT shows an improvement of nonemergency exams while emergency exams are still validated within the maximum time imposed by the hospital. The strategy adopted by the management, which was based on re-using the available equipment and staff when merging the pre-existing laboratories, has reached its goal: introducing automation while minimizing the costs.

  8. Parallel Digital Phase-Locked Loops

    NASA Technical Reports Server (NTRS)

    Sadr, Ramin; Shah, Biren N.; Hinedi, Sami M.

    1995-01-01

    Wide-band microwave receivers of proposed type include digital phase-locked loops in which band-pass filtering and down-conversion of input signals implemented by banks of multirate digital filters operating in parallel. Called "parallel digital phase-locked loops" to distinguish them from other digital phase-locked loops. Systems conceived as cost-effective solution to problem of filtering signals at high sampling rates needed to accommodate wide input frequency bands. Each of M filters process 1/M of spectrum of signal.

  9. Workflow efficiency of two 1.5 T MR scanners with and without an automated user interface for head examinations.

    PubMed

    Moenninghoff, Christoph; Umutlu, Lale; Kloeters, Christian; Ringelstein, Adrian; Ladd, Mark E; Sombetzki, Antje; Lauenstein, Thomas C; Forsting, Michael; Schlamann, Marc

    2013-06-01

    Workflow efficiency and workload of radiological technologists (RTs) were compared in head examinations performed with two 1.5 T magnetic resonance (MR) scanners equipped with or without an automated user interface called "day optimizing throughput" (Dot) workflow engine. Thirty-four patients with known intracranial pathology were examined with a 1.5 T MR scanner with Dot workflow engine (Siemens MAGNETOM Aera) and with a 1.5 T MR scanner with conventional user interface (Siemens MAGNETOM Avanto) using four standardized examination protocols. The elapsed time for all necessary work steps, which were performed by 11 RTs within the total examination time, was compared for each examination at both MR scanners. The RTs evaluated the user-friendliness of both scanners by a questionnaire. Normality of distribution was checked for all continuous variables by use of the Shapiro-Wilk test. Normally distributed variables were analyzed by Student's paired t-test, otherwise Wilcoxon signed-rank test was used to compare means. Total examination time of MR examinations performed with Dot engine was reduced from 24:53 to 20:01 minutes (P < .001) and the necessary RT intervention decreased by 61% (P < .001). The Dot engine's automated choice of MR protocols was significantly better assessed by the RTs than the conventional user interface (P = .001). According to this preliminary study, the Dot workflow engine is a time-saving user assistance software, which decreases the RTs' effort significantly and may help to automate neuroradiological examinations for a higher workflow efficiency. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  10. A racetrack mode-locked silicon evanescent laser.

    PubMed

    Fang, Alexander W; Koch, Brian R; Gan, Kian-Giap; Park, Hyundai; Jones, Richard; Cohen, Oded; Paniccia, Mario J; Blumenthal, Daniel J; Bowers, John E

    2008-01-21

    By utilizing a racetrack resonator topography, an on-chip mode locked silicon evanescent laser (ML-SEL) is realized that is independent of facet polishing. This enables integration with other devices on silicon and precise control of the ML-SEL's repetition rate through lithographic definition of the cavity length. Both passive and hybrid mode-locking have been achieved with transform limited, 7 ps pulses emitted at a repetition rate of 30 GHz. Jitter and locking range are measured under hybrid mode locking with a minimum absolute jitter and maximum locking range of 364 fs, and 50 MHz, respectively.

  11. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.

    PubMed

    Estes, Chris; Rhee, Peter; Shrader, M Wade; Csavina, Kristine; Jacofsky, Marc C; Jacofsky, David J

    2008-01-01

    The purpose of this study was to compare the biomechanical properties of a contoured locking plate instrumented with either an all-locked or hybrid locked/nonlocked screw construct in a proximal metaphyseal fracture of the tibia (AO 41-A3.2). A standardized proximal metaphyseal wedge osteotomy (AO 41-A3.2) was created in five pairs of cadaveric tibia. Each pair was randomly instrumented with either an all-locked or combination locked/nonlocked screw construct using a locked contoured periarticular plate (Peri-Loc periarticular locked plating system, Smith & Nephew, Memphis, TN). Vertical subsidence (irreversible deformation) and deflection (reversible deformation) in each pair were analyzed and compared. Load to failure, defined by complete fracture gap closure, was also determined. There was no statistically significant difference in vertical subsidence (P = 0.19) or deflection (P = 0.19) of the proximal tibia between the all-locked and combination locked/nonlocked screw construct with increasing levels of cyclical axial load from 200 to 1200 N. Failure occurred at a mean value of 2160 N in the locked group and 1760 N in the hybrid group (P = 0.19); the failure mode was plate bending in all specimens. The results indicate that the use of compression screws with locked screws in this particular construct allows a similar amount of irreversible and reversible deformation in response to an axial load when compared to an all-locked screw construct. This suggests that there is no statistically significant difference in the stability in fixation between the two methods, allowing the surgeon the freedom to choose the appropriate screw combination unique to each fracture.

  12. Evaluation of negative results of BacT/Alert 3D automated blood culture system.

    PubMed

    Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal

    2005-06-01

    Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

  13. 49 CFR 236.339 - Mechanical locking, maintenance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Mechanical locking, maintenance requirements. 236... Interlocking Rules and Instructions § 236.339 Mechanical locking, maintenance requirements. Locking and... prevented: (a) Mechanical machine—(1) Latch-operated locking. Raising lever latch block so that bottom...

  14. Robust tilt and lock mechanism for hopping actuator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of themore » grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.« less

  15. 49 CFR 236.758 - Lock, electric, forced drop.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Lock, electric, forced drop. 236.758 Section 236.758 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.758 Lock, electric, forced drop. An electric lock in which the locking member is mechanically...

  16. 49 CFR 236.758 - Lock, electric, forced drop.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Lock, electric, forced drop. 236.758 Section 236.758 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.758 Lock, electric, forced drop. An electric lock in which the locking member is mechanically...

  17. 49 CFR 236.758 - Lock, electric, forced drop.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Lock, electric, forced drop. 236.758 Section 236.758 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.758 Lock, electric, forced drop. An electric lock in which the locking member is mechanically...

  18. 49 CFR 236.758 - Lock, electric, forced drop.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric, forced drop. 236.758 Section 236.758 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.758 Lock, electric, forced drop. An electric lock in which the locking member is mechanically...

  19. Robust quantum data locking from phase modulation

    NASA Astrophysics Data System (ADS)

    Lupo, Cosmo; Wilde, Mark M.; Lloyd, Seth

    2014-08-01

    Quantum data locking is a uniquely quantum phenomenon that allows a relatively short key of constant size to (un)lock an arbitrarily long message encoded in a quantum state, in such a way that an eavesdropper who measures the state but does not know the key has essentially no information about the message. The application of quantum data locking in cryptography would allow one to overcome the limitations of the one-time pad encryption, which requires the key to have the same length as the message. However, it is known that the strength of quantum data locking is also its Achilles heel, as the leakage of a few bits of the key or the message may in principle allow the eavesdropper to unlock a disproportionate amount of information. In this paper we show that there exist quantum data locking schemes that can be made robust against information leakage by increasing the length of the key by a proportionate amount. This implies that a constant size key can still lock an arbitrarily long message as long as a fraction of it remains secret to the eavesdropper. Moreover, we greatly simplify the structure of the protocol by proving that phase modulation suffices to generate strong locking schemes, paving the way to optical experimental realizations. Also, we show that successful data locking protocols can be constructed using random code words, which very well could be helpful in discovering random codes for data locking over noisy quantum channels.

  20. Digital output compensation for precise frequency transfer over commercial fiber link

    NASA Astrophysics Data System (ADS)

    Ci, Cheng; Wu, Hong; Tang, Ran; Liu, Bo; Chen, Xing; Zhang, Xue-song; Zhang, Yu; Zhao, Ying-xin

    2018-03-01

    An ultra-highly precise and long-term stable frequency transmission system over 120 km commercial fiber link has been proposed and experimentally demonstrated. This system is based on digital output compensation technique to suppress phase fluctuations during the frequency transmission process. A mode-locked erbium-doped fiber laser driven by a hydrogen maser serves as an optical transmitter. Moreover, a dense wavelength division multiplexing system is able to separate forward and backward signals with reflection effect excluded. The ultimate fractional frequency instabilities for the long-distance frequency distributed system are up to 3.14×10-15 at 1 s and 2.96×10-19 at 10 000 s, respectively.

  1. Self-mode-locking semiconductor disk laser.

    PubMed

    Gaafar, Mahmoud; Richter, Philipp; Keskin, Hakan; Möller, Christoph; Wichmann, Matthias; Stolz, Wolfgang; Rahimi-Iman, Arash; Koch, Martin

    2014-11-17

    The development of mode-locked semiconductor disk lasers received striking attention in the last 14 years and there is still a vast potential of such pulsed lasers to be explored and exploited. While for more than one decade pulsed operation was strongly linked to the employment of a saturable absorber, self-mode-locking emerged recently as an effective and novel technique in this field - giving prospect to a reduced complexity and improved cost-efficiency of such lasers. In this work, we highlight recent achievements regarding self-mode-locked semiconductor devices. It is worth to note, that although nonlinear effects in the active medium are expected to give rise to self-mode-locking, this has to be investigated with care in future experiments. However, there is a controversy whether results presented with respect to self-mode-locking truly show mode-locking. Such concerns are addressed in this work and we provide a clear evidence of mode-locking in a saturable-absorber-free device. By using a BBO crystal outside the cavity, green light originating from second-harmonic generation using the out-coupled laser beam is demonstrated. In addition, long-time-span pulse trains as well as radiofrequency-spectra measurements are presented for our sub-ps pulses at 500 MHz repetition rate which indicate the stable pulse operation of our device. Furthermore, a long-time-span autocorrelation trace is introduced which clearly shows absence of a pedestal or double pulses. Eventually, a beam-profile measurement reveals the excellent beam quality of our device with an M-square factor of less than 1.1 for both axes, showing that self-mode-locking can be achieved for the fundamental transverse mode.

  2. In Vitro Assessment of the Antimicrobial Efficacy of Optimized Nitroglycerin-Citrate-Ethanol as a Nonantibiotic, Antimicrobial Catheter Lock Solution for Prevention of Central Line-Associated Bloodstream Infections

    PubMed Central

    Reitzel, Ruth A.; Hirsh-Ginsberg, Cheryl; Murray, Kimberly; Chaftari, Anne-Marie; Hachem, Ray; Raad, Issam

    2016-01-01

    The rapid, broad-spectrum, biofilm-eradicating activity of the combination of 0.01% nitroglycerin, 7% citrate, and 20% ethanol and its potential as a nonantibiotic, antimicrobial catheter lock solution (ACLS) were previously reported. Here, a nitroglycerin-citrate-ethanol (NiCE) ACLS optimized for clinical assessment was developed by reducing the nitroglycerin and citrate concentrations and increasing the ethanol concentration. Biofilm-eradicating activity was sustained when the ethanol concentration was increased from 20 to 22% which fully compensated for reducing the citrate concentration from 7% to 4% as well as the nitroglycerin concentration from 0.01% to 0.0015% or 0.003%. The optimized formulations demonstrated complete and rapid (2 h) eradication of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-intermediate Staphylococcus aureus (VISA), methicillin-resistant Staphylococcus epidermidis (MRSE), vancomycin-resistant enterococci (VRE), multidrug-resistant (MDR) Pseudomonas aeruginosa, MDR Klebsiella pneumoniae, MDR Enterobacter cloacae, MDR Acinetobacter baumannii, MDR Escherichia coli, MDR Stenotrophomonas maltophilia, Candida albicans, and Candida glabrata biofilms. The optimized NiCE lock solutions demonstrated anticoagulant activities comparable to those of heparin lock solutions. NiCE lock solution was significantly more effective than taurolidine-citrate-heparin lock solution in eradicating biofilms of Staphylococcus aureus and Candida glabrata. The optimized, nonantibiotic, heparin-free NiCE lock solution demonstrates rapid broad-spectrum biofilm eradication as well as effective anticoagulant activity, making NiCE a high-quality ACLS candidate for clinical assessment. PMID:27297475

  3. Microcontroller-based locking in optics experiments.

    PubMed

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  4. Microcontroller-based locking in optics experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, K.; State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062; Le Jeannic, H.

    2014-12-15

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of opticalmore » experiments.« less

  5. Locking Nut and Bolt

    NASA Technical Reports Server (NTRS)

    Bishop, R.

    1983-01-01

    Threaded fastener locks parts securely together despite together large loosening torques, even under conditions of high temperature and vibration. Positive locking action is suitable for use where conventional fasteners tend to work loose--for example, on high-speed rotating machinery. Bolt, nut and key are joined together so key occupies alined slots in bolt and nut and prevents nut from rotating off bolt.

  6. Rotatable stem and lock

    DOEpatents

    Deveney, Joseph E.; Sanderson, Stephen N.

    1984-01-01

    A valve stem and lock include a housing surrounding a valve stem, a solenoid affixed to an interior wall of the housing, an armature affixed to the valve stem and a locking device for coupling the armature to the housing body. When the solenoid is energized, the solenoid moves away from the housing body, permitting rotation of the valve stem.

  7. Rotatable stem and lock

    DOEpatents

    Deveney, J.E.; Sanderson, S.N.

    1981-10-27

    A valve stem and lock is disclosed which includes a housing surrounding a valve stem, a solenoid affixed to an interior wall of the housing, an armature affixed to the valve stem and a locking device for coupling the armature to the housing body. When the solenoid is energized, the solenoid moves away from the housing body, permitting rotation of the valve stem.

  8. Barcoding T Cell Calcium Response Diversity with Methods for Automated and Accurate Analysis of Cell Signals (MAAACS)

    PubMed Central

    Sergé, Arnauld; Bernard, Anne-Marie; Phélipot, Marie-Claire; Bertaux, Nicolas; Fallet, Mathieu; Grenot, Pierre; Marguet, Didier; He, Hai-Tao; Hamon, Yannick

    2013-01-01

    We introduce a series of experimental procedures enabling sensitive calcium monitoring in T cell populations by confocal video-microscopy. Tracking and post-acquisition analysis was performed using Methods for Automated and Accurate Analysis of Cell Signals (MAAACS), a fully customized program that associates a high throughput tracking algorithm, an intuitive reconnection routine and a statistical platform to provide, at a glance, the calcium barcode of a population of individual T-cells. Combined with a sensitive calcium probe, this method allowed us to unravel the heterogeneity in shape and intensity of the calcium response in T cell populations and especially in naive T cells, which display intracellular calcium oscillations upon stimulation by antigen presenting cells. PMID:24086124

  9. Bandwidth controller for phase-locked-loop

    NASA Technical Reports Server (NTRS)

    Brockman, Milton H. (Inventor)

    1992-01-01

    A phase locked loop utilizing digital techniques to control the closed loop bandwidth of the RF carrier phase locked loop in a receiver provides high sensitivity and a wide dynamic range for signal reception. After analog to digital conversion, a digital phase locked loop bandwidth controller provides phase error detection with automatic RF carrier closed loop tracking bandwidth control to accommodate several modes of transmission.

  10. Phase-lock loop frequency control and the dropout problem

    NASA Technical Reports Server (NTRS)

    Attwood, S.; Kline, A. J.

    1968-01-01

    Technique automatically sets the frequency of narrow band phase-lock loops within automatic lock-in-range. It presets a phase-lock loop to a desired center frequency with a closed loop electronic frequency discriminator and holds the phase-lock loop to that center frequency until lock is achieved.

  11. Heterogeneous Silicon III-V Mode-Locked Lasers

    NASA Astrophysics Data System (ADS)

    Davenport, Michael Loehrlein

    Mode-locked lasers are useful for a variety of applications, such as sensing, telecommunication, and surgical instruments. This work focuses on integrated-circuit mode-locked lasers: those that combine multiple optical and electronic functions and are manufactured together on a single chip. While this allows production at high volume and lower cost, the true potential of integration is to open applications for mode-locked laser diodes where solid state lasers cannot fit, either due to size and power consumption constraints, or where small optical or electrical paths are needed for high bandwidth. Unfortunately, most high power and highly stable mode-locked laser diode demonstrations in scientific literature are based on the Fabry-Perot resonator design, with cleaved mirrors, and are unsuitable for use in integrated circuits because of the difficulty of producing integrated Fabry-Perot cavities. We use silicon photonics and heterogeneous integration with III-V gain material to produce the most powerful and lowest noise fully integrated mode-locked laser diode in the 20 GHz frequency range. If low noise and high peak power are required, it is arguably the best performing fully integrated mode-locked laser ever demonstrated. We present the design methodology and experimental pathway to realize a fully integrated mode-locked laser diode. The construction of the device, beginning with the selection of an integration platform, and proceeding through the fabrication process to final optimization, is presented in detail. The dependence of mode-locked laser performance on a wide variety of design parameters is presented. Applications for integrated circuit mode-locked lasers are also discussed, as well as proposed methods for using integration to improve mode-locking performance to beyond the current state of the art.

  12. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  13. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  14. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  15. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  16. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  17. Suppressing Transients In Digital Phase-Locked Loops

    NASA Technical Reports Server (NTRS)

    Thomas, J. B.

    1993-01-01

    Loop of arbitrary order starts in steady-state lock. Method for initializing variables of digital phase-locked loop reduces or eliminates transients in phase and frequency typically occurring during acquisition of lock on signal or when changes made in values of loop-filter parameters called "loop constants". Enables direct acquisition by third-order loop without prior acquisition by second-order loop of greater bandwidth, and eliminates those perturbations in phase and frequency lock occurring when loop constants changed by arbitrarily large amounts.

  18. Biomechanics of far cortical locking.

    PubMed

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  19. 49 CFR 236.387 - Movable bridge locking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Movable bridge locking. 236.387 Section 236.387 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... and Tests § 236.387 Movable bridge locking. Movable bridge locking shall be tested at least once a...

  20. 49 CFR 236.387 - Movable bridge locking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Movable bridge locking. 236.387 Section 236.387 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... and Tests § 236.387 Movable bridge locking. Movable bridge locking shall be tested at least once a...

  1. A fast-locking all-digital delay-locked loop for phase/delay generation in an FPGA

    NASA Astrophysics Data System (ADS)

    Zhujia, Chen; Haigang, Yang; Fei, Liu; Yu, Wang

    2011-10-01

    A fast-locking all-digital delay-locked loop (ADDLL) is proposed for the DDR SDRAM controller interface in a field programmable gate array (FPGA). The ADDLL performs a 90° phase-shift so that the data strobe (DQS) can enlarge the data valid window in order to minimize skew. In order to further reduce the locking time and to prevent the harmonic locking problem, a time-to-digital converter (TDC) is proposed. A duty cycle corrector (DCC) is also designed in the ADDLL to adjust the output duty cycle to 50%. The ADDLL, implemented in a commercial 0.13 μm CMOS process, occupies a total of 0.017 mm2 of active area. Measurement results show that the ADDLL has an operating frequency range of 75 to 350 MHz and a total delay resolution of 15 ps. The time interval error (TIE) of the proposed circuit is 60.7 ps.

  2. Acquisition and Tracking Behavior of Phase-Locked Loops

    NASA Technical Reports Server (NTRS)

    Viterbi, A. J.

    1958-01-01

    Phase-locked or APC loops have found increasing applications in recent years as tracking filters, synchronizing devices, and narrowband FM discriminators. Considerable work has been performed to determine the noise-squelching properties of the loop when it is operating in or near phase lock and is functioning as a linear coherent detector. However, insufficient consideration has been devoted to the non-linear behavior of the loop when it is out of lock and in the process of pulling in. Experimental evidence has indicated that there is a strong tendency for phase-locked loops to achieve lock under most circumstances. However, the analysis which has appeared in the literature iis limited to the acquisition of a constant frequency reference signal with only one phase-locked loop filter configuration. This work represents an investigation of frequency acquisition properties of phase-locked loops for a variety of reference-signal behavior and loop configurations

  3. Compensation Effect in the Electrical Conduction Process in Some Nucleic Acid Base Complexes with Proflavine Dye

    NASA Astrophysics Data System (ADS)

    Sarkar, D.; Misra, T. N.

    1988-11-01

    Compensation behaviour has been found in electrical conduction process in proflavine complexes with nucleic acid bases, guanine, adenine, uracil and thymine. At low dye concentrations these semiconducting complexes follow a three constant compensation equation σ(T){=}σ0'\\exp (E/2kT0)\\exp (-E/2kT), σ0' and T0 being constants for a specific base. The other notations have their usual meaning. Consistent values of these constants have been obtained by different experimental methods of evaluation. These results suggest that compensation effect has a physical origin.

  4. I trust it, but I don't know why: effects of implicit attitudes toward automation on trust in an automated system.

    PubMed

    Merritt, Stephanie M; Heimbaugh, Heather; LaChapell, Jennifer; Lee, Deborah

    2013-06-01

    This study is the first to examine the influence of implicit attitudes toward automation on users' trust in automation. Past empirical work has examined explicit (conscious) influences on user level of trust in automation but has not yet measured implicit influences. We examine concurrent effects of explicit propensity to trust machines and implicit attitudes toward automation on trust in an automated system. We examine differential impacts of each under varying automation performance conditions (clearly good, ambiguous, clearly poor). Participants completed both a self-report measure of propensity to trust and an Implicit Association Test measuring implicit attitude toward automation, then performed an X-ray screening task. Automation performance was manipulated within-subjects by varying the number and obviousness of errors. Explicit propensity to trust and implicit attitude toward automation did not significantly correlate. When the automation's performance was ambiguous, implicit attitude significantly affected automation trust, and its relationship with propensity to trust was additive: Increments in either were related to increases in trust. When errors were obvious, a significant interaction between the implicit and explicit measures was found, with those high in both having higher trust. Implicit attitudes have important implications for automation trust. Users may not be able to accurately report why they experience a given level of trust. To understand why users trust or fail to trust automation, measurements of implicit and explicit predictors may be necessary. Furthermore, implicit attitude toward automation might be used as a lever to effectively calibrate trust.

  5. Self-injection locked blue laser

    NASA Astrophysics Data System (ADS)

    Donvalkar, Prathamesh S.; Savchenkov, Anatoliy; Matsko, Andrey

    2018-04-01

    We demonstrate a 446.5 nm GaN semiconductor laser with sub-MHz linewidth. The linewidth reduction is achieved by locking the laser to a magnesium fluoride whispering gallery mode resonator characterized with 109 quality factor. Self-injection locking ensures single longitudinal mode operation of the laser.

  6. 27 CFR 19.193 - Breaking Government locks.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Breaking Government locks... Requirements Other Plant Requirements § 19.193 Breaking Government locks. TTB may assign TTB officers to a distilled spirits plant and utilize controls, such as Government locks, if TTB determines that such measures...

  7. Partial-depth lock-release flows

    NASA Astrophysics Data System (ADS)

    Khodkar, M. A.; Nasr-Azadani, M. M.; Meiburg, E.

    2017-06-01

    We extend the vorticity-based modeling concept for stratified flows introduced by Borden and Meiburg [Z. Borden and E. Meiburg, J. Fluid Mech. 726, R1 (2013), 10.1017/jfm.2013.239] to unsteady flow fields that cannot be rendered quasisteady by a change of reference frames. Towards this end, we formulate a differential control volume balance for the conservation of mass and vorticity in the fully unsteady parts of the flow, which we refer to as the differential vorticity model. We furthermore show that with the additional assumptions of locally uniform parallel flow within each layer, the unsteady vorticity modeling approach reproduces the familiar two-layer shallow-water equations. To evaluate its accuracy, we then apply the vorticity model approach to partial-depth lock-release flows. Consistent with the shallow water analysis of Rottman and Simpson [J. W. Rottman and J. E. Simpson, J. Fluid Mech. 135, 95 (1983), 10.1017/S0022112083002979], the vorticity model demonstrates the formation of a quasisteady gravity current front, a fully unsteady expansion wave, and a propagating bore that is present only if the lock depth exceeds half the channel height. When this bore forms, it travels with a velocity that does not depend on the lock height and the interface behind it is always at half the channel depth. We demonstrate that such a bore is energy conserving. The differential vorticity model gives predictions for the height and velocity of the gravity current and the bore, as well as for the propagation velocities of the edges of the expansion fan, as a function of the lock height. All of these predictions are seen to be in good agreement with the direct numerical simulation data and, where available, with experimental results. An energy analysis shows lock-release flows to be energy conserving only for the case of a full lock, whereas they are always dissipative for partial-depth locks.

  8. Mode Locking of Lasers with Atomic Layer Graphene

    DTIC Science & Technology

    2012-07-01

    polarization components. As in order to obtain the vector soliton operation in a mode locked fiber laser no any polarization ...oscilloscope traces of a polarization locked vector soliton operation state. Figure 21: Oscilloscope traces of pulse train in a phase locked vector ... locked vector solitons , where the polarization of the solitons emitted by the laser is fixed, the polarization of the

  9. Cascaded optical fiber link using the internet network for remote clocks comparison.

    PubMed

    Chiodo, Nicola; Quintin, Nicolas; Stefani, Fabio; Wiotte, Fabrice; Camisard, Emilie; Chardonnet, Christian; Santarelli, Giorgio; Amy-Klein, Anne; Pottie, Paul-Eric; Lopez, Olivier

    2015-12-28

    We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10(-16) at 1-s measurement time and 1x10(-19) at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.

  10. 14 CFR 23.679 - Control system locks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.679 Control system locks. If there is a device to lock the control system on the ground or... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Control system locks. 23.679 Section 23.679...

  11. 14 CFR 23.679 - Control system locks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.679 Control system locks. If there is a device to lock the control system on the ground or... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Control system locks. 23.679 Section 23.679...

  12. 14 CFR 23.679 - Control system locks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.679 Control system locks. If there is a device to lock the control system on the ground or... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system locks. 23.679 Section 23.679...

  13. 14 CFR 23.679 - Control system locks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.679 Control system locks. If there is a device to lock the control system on the ground or... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Control system locks. 23.679 Section 23.679...

  14. 14 CFR 23.679 - Control system locks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.679 Control system locks. If there is a device to lock the control system on the ground or... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Control system locks. 23.679 Section 23.679...

  15. Synchronization of pulses from mode-locked lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, G.T.

    A study of the synchronization of mode-locked lasers is presented. In particular, we investigate the timing of the laser output pulses with respect to the radio frequency (RF) signal driving the mode-locking elements in the laser cavity. Two types of mode-locked lasers are considered: a cw loss-modulated mode-locked argon ion laser; and a q-switched active-passive mode-locked Nd:YAG laser. We develop theoretical models for the treatment of laser pulse synchronization in both types of lasers. Experimental results are presented on a combined laser system that synchronizes pulses from both an argon ion and a Nd:YAG laser by using a common RFmore » signal to drive independent mode-lockers in both laser cavities. Shot to shot jitter as low as 18 ps (RMS) was measured between the output pulses from the two lasers. The theory of pulse synchronization for the cw loss-modulated mode-locked argon ion laser is based on the relationship between the timing of the mode-locked laser pulse (with respect to the peak of the RF signal) and the length of the laser cavity. Experiments on the argon laser include the measurement of the phase shift of the mode-locked pulse as a function of cavity length and intracavity intensity. The theory of synchronization of the active-passive mode-locked Nd:YAG laser is an extension of the pulse selection model of the active-passive laser. Experiments on the active-passive Nd:YAG laser include: measurement of the early noise fluctuations; measurement of the duration of the linear build-up stage (time between laser threshold and saturation of the absorber); measurement of jitter as a function of the mode-locker modulation depth; and measurement of the output pulse phase shift as a function of cavity length.« less

  16. Brain communication in the locked-in state.

    PubMed

    De Massari, Daniele; Ruf, Carolin A; Furdea, Adrian; Matuz, Tamara; van der Heiden, Linda; Halder, Sebastian; Silvoni, Stefano; Birbaumer, Niels

    2013-06-01

    Patients in the completely locked-in state have no means of communication and they represent the target population for brain-computer interface research in the last 15 years. Although different paradigms have been tested and different physiological signals used, to date no sufficiently documented completely locked-in state patient was able to control a brain-computer interface over an extended time period. We introduce Pavlovian semantic conditioning to enable basic communication in completely locked-in state. This novel paradigm is based on semantic conditioning for online classification of neuroelectric or any other physiological signals to discriminate between covert (cognitive) 'yes' and 'no' responses. The paradigm comprised the presentation of affirmative and negative statements used as conditioned stimuli, while the unconditioned stimulus consisted of electrical stimulation of the skin paired with affirmative statements. Three patients with advanced amyotrophic lateral sclerosis participated over an extended time period, one of which was in a completely locked-in state, the other two in the locked-in state. The patients' level of vigilance was assessed through auditory oddball procedures to study the correlation between vigilance level and the classifier's performance. The average online classification accuracies of slow cortical components of electroencephalographic signals were around chance level for all the patients. The use of a non-linear classifier in the offline classification procedure resulted in a substantial improvement of the accuracy in one locked-in state patient achieving 70% correct classification. A reliable level of performance in the completely locked-in state patient was not achieved uniformly throughout the 37 sessions despite intact cognitive processing capacity, but in some sessions communication accuracies up to 70% were achieved. Paradigm modifications are proposed. Rapid drop of vigilance was detected suggesting attentional

  17. Effects of neuromedin-β on caloric compensation, eating behaviours and habitual food intake.

    PubMed

    Blanchet, Rosanne; Lemieux, Simone; Couture, Patrick; Bouchard, Luigi; Vohl, Marie-Claude; Pérusse, Louis

    2011-08-01

    We have previously shown that a missense mutation (p.P73T) located in the neuromedin-β gene, a satiety peptide, was associated with higher levels of disinhibition, susceptibility to hunger, and body weight gain over time. In this study we compare caloric compensation, eating behaviour traits, food intake and adiposity between premenopausal women with (T73T) and without (P73P) mutation. Subjects (N=153) were screened to find homozygous women (T73T) that were matched for age, BMI and use of oral contraceptives with 7 women (P73P) not carrying the mutation. Eating behaviour traits were assessed with the Three-Factors Eating Questionnaire and habitual dietary intakes with a 3-day dietary record. A randomized single-blind cross-over design was used to test the effect of p.P73T on caloric compensation. We measured appetite sensations and ad libitum dietary intake following two different energy preloads. We found no difference in eating behaviour traits, adiposity, appetite sensations, ad libitum dietary intake and caloric compensation. However, T73T women had lower habitual energy and carbohydrate intakes than P73P. Differences in carbohydrate intakes disappeared when expressed in percentage of energy. These results suggest that the neuromedin-β p.P73T mutation modulates energy intake without effects on macronutrient. A lack of power resulting from our difficulty to recruit enough T73T women precludes any definitive conclusion regarding the impact of this mutation on caloric compensation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Push-To-Lock, Push-To-Release Mechanism

    NASA Technical Reports Server (NTRS)

    Lozano, Anselmo, Jr.

    1991-01-01

    Latch locked or unlocked with single motion of hand. No tools needed to operate it, and user easily opens or closes it with heavily gloved hand. When unlocked, stem free of main body. In locked state, dowel pins in main body hold stem. Latch equipped with lock and key so only authorized users operate it.

  19. 14 CFR 29.679 - Control system locks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system locks. 29.679 Section 29.679... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.679 Control system locks. If there is a device to lock the control system with the rotorcraft on the ground or water, there...

  20. 14 CFR 27.679 - Control system locks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system locks. 27.679 Section 27.679... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.679 Control system locks. If there is a device to lock the control system with the rotorcraft on the ground or water, there...

  1. 14 CFR 27.679 - Control system locks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.679 Control system locks. If there is a device to lock the control system with the rotorcraft on the ground or water, there... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Control system locks. 27.679 Section 27.679...

  2. 14 CFR 29.679 - Control system locks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.679 Control system locks. If there is a device to lock the control system with the rotorcraft on the ground or water, there... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Control system locks. 29.679 Section 29.679...

  3. 49 CFR 236.780 - Plunger, facing point lock.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.780 Plunger, facing point lock. That part of a facing point lock which secures the lock rod to the...

  4. 49 CFR 236.780 - Plunger, facing point lock.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.780 Plunger, facing point lock. That part of a facing point lock which secures the lock rod to the...

  5. 49 CFR 236.780 - Plunger, facing point lock.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.780 Plunger, facing point lock. That part of a facing point lock which secures the lock rod to the...

  6. 49 CFR 236.780 - Plunger, facing point lock.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.780 Plunger, facing point lock. That part of a facing point lock which secures the lock rod to the...

  7. 49 CFR 236.780 - Plunger, facing point lock.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.780 Plunger, facing point lock. That part of a facing point lock which secures the lock rod to the...

  8. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    PubMed

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  9. In Vitro Assessment of the Antimicrobial Efficacy of Optimized Nitroglycerin-Citrate-Ethanol as a Nonantibiotic, Antimicrobial Catheter Lock Solution for Prevention of Central Line-Associated Bloodstream Infections.

    PubMed

    Reitzel, Ruth A; Rosenblatt, Joel; Hirsh-Ginsberg, Cheryl; Murray, Kimberly; Chaftari, Anne-Marie; Hachem, Ray; Raad, Issam

    2016-09-01

    The rapid, broad-spectrum, biofilm-eradicating activity of the combination of 0.01% nitroglycerin, 7% citrate, and 20% ethanol and its potential as a nonantibiotic, antimicrobial catheter lock solution (ACLS) were previously reported. Here, a nitroglycerin-citrate-ethanol (NiCE) ACLS optimized for clinical assessment was developed by reducing the nitroglycerin and citrate concentrations and increasing the ethanol concentration. Biofilm-eradicating activity was sustained when the ethanol concentration was increased from 20 to 22% which fully compensated for reducing the citrate concentration from 7% to 4% as well as the nitroglycerin concentration from 0.01% to 0.0015% or 0.003%. The optimized formulations demonstrated complete and rapid (2 h) eradication of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-intermediate Staphylococcus aureus (VISA), methicillin-resistant Staphylococcus epidermidis (MRSE), vancomycin-resistant enterococci (VRE), multidrug-resistant (MDR) Pseudomonas aeruginosa, MDR Klebsiella pneumoniae, MDR Enterobacter cloacae, MDR Acinetobacter baumannii, MDR Escherichia coli, MDR Stenotrophomonas maltophilia, Candida albicans, and Candida glabrata biofilms. The optimized NiCE lock solutions demonstrated anticoagulant activities comparable to those of heparin lock solutions. NiCE lock solution was significantly more effective than taurolidine-citrate-heparin lock solution in eradicating biofilms of Staphylococcus aureus and Candida glabrata The optimized, nonantibiotic, heparin-free NiCE lock solution demonstrates rapid broad-spectrum biofilm eradication as well as effective anticoagulant activity, making NiCE a high-quality ACLS candidate for clinical assessment. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. 408-fs SESAM mode locked Cr:ZnSe laser

    NASA Astrophysics Data System (ADS)

    Bu, Xiangbao; Shi, Yuhang; Xu, Jia; Li, Huijuan; Wang, Pu

    2018-01-01

    We report self-starting femtosecond operation of a 127-MHz SESAM mode locked Cr:ZnSe laser around 2420 nm. A thulium doped double clad fiber laser at 1908 nm was used as the pumping source. In the normal dispersion regime, stable pulse pairs with constant phase differences in the multipulse regime were observed. The maximum output power was 342 mW with respect to incident pump power of 4.8 W and the corresponding slope efficiency was 10.4%. By inserting a piece of sapphire plate, dispersion compensation was achieved and the intra-cavity dispersion was moved to the anomalous regime. A maximum output power of 403 mW was obtained and the corresponding slope efficiency was 12.2%. Pulse width was measured to be 408 fs by a collinear autocorrelator using two-photon absorption in an InGaAs photodiode. The laser spectrum in multipulse operation showed a clear periodic modulation.

  11. Efficient dynamic coherence transfer relying on offset locking using optical phase-locked loop

    NASA Astrophysics Data System (ADS)

    Xie, Weilin; Dong, Yi; Bretenaker, Fabien; Shi, Hongxiao; Zhou, Qian; Xia, Zongyang; Qin, Jie; Zhang, Lin; Lin, Xi; Hu, Weisheng

    2018-01-01

    We design and experimentally demonstrate a highly efficient coherence transfer based on composite optical phaselocked loop comprising multiple feedback servo loops. The heterodyne offset-locking is achieved by conducting an acousto-optic frequency shifter in combination with the current tuning and the temperature controlling of the semiconductor laser. The adaptation of the composite optical phase-locked loop enables the tight coherence transfer from a frequency comb to a semiconductor laser in a fully dynamic manner.

  12. Montgomery Point Lock and Dam, White River, Arkansas

    DTIC Science & Technology

    2016-01-01

    ER D C/ CH L TR -1 6- 1 Monitoring Completed Navigation Projects (MCNP) Program Montgomery Point Lock and Dam, White River, Arkansas Co...Navigation Projects (MCNP) Program ERDC/CHL TR-16-1 January 2016 Montgomery Point Lock and Dam, White River, Arkansas Allen Hammack, Michael Winkler, and...20314-1000 Under MCNP Work Unit: Montgomery Point Lock and Dam, White River, Arkansas ERDC/CHL TR-16-1 ii Abstract Montgomery Point Lock and

  13. Phase-locked loops and their application

    NASA Technical Reports Server (NTRS)

    Lindsey, W. C. (Editor); Simon, M. K.

    1978-01-01

    A collection of papers is presented on the characteristics and capabilities of phase-locked loops (PLLs), along with some applications of interest. The discussion covers basic theory (linear and nonlinear); acquisition; threshold; stability; frequency demodulation and detection; tracking; cycle slipping and loss of lock; phase-locked oscillators; operation and performance in the presence of noise; AGC, AFC, and APC circuits and systems; digital PLL; and applications and miscellaneous. With the rapid development of IC technology, PLLs are expected to be used widely in consumer electronics.

  14. Electronic neutron sources for compensated porosity well logging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, A. X.; Antolak, A. J.; Leung, K. -N.

    2012-08-01

    The viability of replacing Americium–Beryllium (Am–Be) radiological neutron sources in compensated porosity nuclear well logging tools with D–T or D–D accelerator-driven neutron sources is explored. The analysis consisted of developing a model for a typical well-logging borehole configuration and computing the helium-3 detector response to varying formation porosities using three different neutron sources (Am–Be, D–D, and D–T). The results indicate that, when normalized to the same source intensity, the use of a D–D neutron source has greater sensitivity for measuring the formation porosity than either an Am–Be or D–T source. The results of the study provide operational requirements that enablemore » compensated porosity well logging with a compact, low power D–D neutron generator, which the current state-of-the-art indicates is technically achievable.« less

  15. Entropy driven key-lock assembly.

    PubMed

    Odriozola, G; Jiménez-Angeles, F; Lozada-Cassou, M

    2008-09-21

    The effective interaction between a sphere with an open cavity (lock) and a spherical macroparticle (key), both immersed in a hard sphere fluid, is studied by means of Monte Carlo simulations. As a result, a two-dimensional map of the key-lock effective interaction potential is constructed, which leads to the proposal of a self-assembling mechanism: There exists trajectories through which the key-lock pair could assemble avoiding trespassing potential barriers. Hence, solely the entropic contribution can induce their self-assembling even in the absence of attractive forces. This study points out the solvent contribution within the underlying mechanisms of substrate-protein assemblydisassembly processes, which are important steps of the enzyme catalysis and protein mediated transport.

  16. Entropy driven key-lock assembly

    NASA Astrophysics Data System (ADS)

    Odriozola, G.; Jiménez-Ángeles, F.; Lozada-Cassou, M.

    2008-09-01

    The effective interaction between a sphere with an open cavity (lock) and a spherical macroparticle (key), both immersed in a hard sphere fluid, is studied by means of Monte Carlo simulations. As a result, a two-dimensional map of the key-lock effective interaction potential is constructed, which leads to the proposal of a self-assembling mechanism: There exists trajectories through which the key-lock pair could assemble avoiding trespassing potential barriers. Hence, solely the entropic contribution can induce their self-assembling even in the absence of attractive forces. This study points out the solvent contribution within the underlying mechanisms of substrate-protein assembly/disassembly processes, which are important steps of the enzyme catalysis and protein mediated transport.

  17. Theoretical analysis of a method for extracting the phase of a phase-amplitude modulated signal generated by a direct-modulated optical injection-locked semiconductor laser

    NASA Astrophysics Data System (ADS)

    Lee, Hwan; Cho, Jun-Hyung; Sung, Hyuk-Kee

    2017-05-01

    The phase modulation (PM) and amplitude modulation (AM) of optical signals can be achieved using a direct-modulated (DM) optical injection-locked (OIL) semiconductor laser. We propose and theoretically analyze a simple method to extract the phase component of a PM signal produced by a DM-OIL semiconductor laser. The pure AM component of the combined PM-AM signal can be isolated by square-law detection in a photodetector and can then be used to compensate for the PM-AM signal based on an optical homodyne method. Using the AM compensation technique, we successfully developed a simple and cost-effective phase extraction method applicable to the PM-AM optical signal of a DM-OIL semiconductor laser.

  18. Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer

    NASA Astrophysics Data System (ADS)

    Jagt, Thyrza; Breedveld, Sebastiaan; van de Water, Steven; Heijmen, Ben; Hoogeman, Mischa

    2017-06-01

    Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for ‘densities-of-the-day’ was created: (1) restoration of spot positions (Bragg peaks) by adapting the energy of each pencil beam to the new water equivalent path length; and (2) re-optimization of pencil beam weights by minimizing the dosimetric difference with the planned dose distribution, using a fast and exact quadratic solver. The method was developed and evaluated using 8-10 repeat CT scans of 10 prostate cancer patients. Experiments demonstrated that giving a high weight to the PTV in the re-optimization resulted in clinically acceptable restorations. For all scans we obtained V 95%  ⩾  98% and V 107%  ⩽  2%. For the bladder, the differences between the restored and the intended treatment plan were below  +2 Gy and  +2%-point. The rectum differences were below  +2 Gy and  +2%-point for 90% of the scans. In the remaining scans the rectum was filled with air, which partly overlapped with the PTV. The air cavity distorted the Bragg peak resulting in less favorable rectum doses.

  19. Side-locked headaches: an algorithm-based approach.

    PubMed

    Prakash, Sanjay; Rathore, Chaturbhuj

    2016-12-01

    The differential diagnosis of strictly unilateral hemicranial pain includes a large number of primary and secondary headaches and cranial neuropathies. It may arise from both intracranial and extracranial structures such as cranium, neck, vessels, eyes, ears, nose, sinuses, teeth, mouth, and the other facial or cervical structure. Available data suggest that about two-third patients with side-locked headache visiting neurology or headache clinics have primary headaches. Other one-third will have either secondary headaches or neuralgias. Many of these hemicranial pain syndromes have overlapping presentations. Primary headache disorders may spread to involve the face and / or neck. Even various intracranial and extracranial pathologies may have similar overlapping presentations. Patients may present to a variety of clinicians, including headache experts, dentists, otolaryngologists, ophthalmologist, psychiatrists, and physiotherapists. Unfortunately, there is not uniform approach for such patients and diagnostic ambiguity is frequently encountered in clinical practice.Herein, we review the differential diagnoses of side-locked headaches and provide an algorithm based approach for patients presenting with side-locked headaches. Side-locked headache is itself a red flag. So, the first priority should be to rule out secondary headaches. A comprehensive history and thorough examinations will help one to formulate an algorithm to rule out or confirm secondary side-locked headaches. The diagnoses of most secondary side-locked headaches are largely investigations dependent. Therefore, each suspected secondary headache should be subjected for appropriate investigations or referral. The diagnostic approach of primary side-locked headache starts once one rule out all the possible secondary headaches. We have discussed an algorithmic approach for both secondary and primary side-locked headaches.

  20. 1.6 μm dissipative soliton fiber laser mode-locked by cesium lead halide perovskite quantum dots.

    PubMed

    Liu, Bang; Gao, Lei; Cheng, Wei Wei; Tang, Xiao Sheng; Gao, Chao; Cao, Yu Long; Li, Yu Jia; Zhu, Tao

    2018-03-19

    We demonstrate a stable, picosecond fiber laser mode-locked by cesium lead halide perovskite quantum dots (CsPbBr 3 -QDs). The saturable absorber is produced by depositing the CsPbBr3-QDs nanocrystals onto the endface of a fiber ferrule through light pressure. A balanced two-detector measurement shows that it has a modulation depth of 2.5% and a saturation power of 17.29 MW/cm 2 . After incorporating the fabricated device into an Er 3+ -doped fiber ring cavity with a net normal dispersion of 0.238 ps 2 , we obtain stable dissipative soliton with a pulse duration of 14.4 ps and a center wavelength at 1600 nm together with an edge-to-dege bandwidth of 4.5 nm. The linear chirped phase can be compensated by 25 m single mode fiber, resulting into a compressed pulse duration of 1.046 ps. This experimental works proves that such CsPbBr3-QDs materials are effective choice for ultrafast laser operating with devious mode-locking states.

  1. Universal spin-momentum locked optical forces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalhor, Farid; Thundat, Thomas; Jacob, Zubin, E-mail: zjacob@purdue.edu

    2016-02-08

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, the direction of decay, and the direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and HE{sub 11} mode of an optical fiber. Furthermore, we explain how the recently reportedmore » phenomena of lateral optical force on chiral and achiral particles are caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from the well-known orbital angular momentum of light. Our work presents a unified view on spin-momentum locking and how it affects optical forces on chiral and achiral particles.« less

  2. VIEW LOOKING NORTHEAST, LOCK 35 IS ON THE RIGHT. CANAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW LOOKING NORTHEAST, LOCK 35 IS ON THE RIGHT. CANAL WORKERS ARE CLEANING TRASH GRATES TO LOCK 35 WATER INLET. ENTRANCE TO OLD LOCK 71 ON LEFT. NOTE THE SEDIMENT BUILD UP IN THE ENTRANCE CHANNEL TO OLD LOCK 71. - New York State Barge Canal, Lockport Locks, Richmond Avenue, Lockport, Niagara County, NY

  3. Navigation lock for Bonneville Dam, Columbia River, Oregon. Volume II. Appendix A. Pressures during lock operations. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockstill, R.L.; George, J.F.

    1996-09-01

    Tests were conducted on two different 1:25-scale models of the New Bonneville Lock located on the Columbia River in Oregon. The lock models were built to study the filling and emptying systems, which consisted of designs utilizing bottom longitudinal floor culverts. The first design studied, defined as the H-H pattern system, consisted of four longitudinal flood culverts in each end of the lock chamber. The second system studied had two longitudinal floor culverts in each end of the lock chamber and was defined as the H pattern system. In the H-H pattern system, the filling culverts, which were located undermore » the lock chamber floor, connected to a crossover culvert with a horizontal splitter wall dividing the flow to upstream and downstream splitter manifolds were equal divisions led into four longitudinal flood culverts in each end of the lock chamber. With the type 6 (recommended) design and a 1-min valve opening time, the lock chamber filled in 8.7 min and emptied in 12.1 min. Due to differences in friction losses, the prototype can be expected to fill and empty about 20 percent faster than the model (7.0 min and 9.7 min, respectively). Modifications involving installing a slope in the lower sill and a v-notch design in the high sill were significant factors that resulted in fast filling and emptying times, low hawser forces, and only minor movement with various tow arrangements for different operating scenarios.« less

  4. Injection locking of optomechanical oscillators via acoustic waves.

    PubMed

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-02

    Injection locking is an effective technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators. As such, exploring new mechanisms for injection locking of emerging oscillators is important for their usage in various systems. Here, we present the first demonstration of injection locking of a radiation pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can be easily implemented on various platforms to lock different types of OMOs independent of their size and structure. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance, matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity, and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology, and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  5. Reconstructing matter profiles of spherically compensated cosmic regions in ΛCDM cosmology

    NASA Astrophysics Data System (ADS)

    de Fromont, Paul; Alimi, Jean-Michel

    2018-02-01

    The absence of a physically motivated model for large-scale profiles of cosmic voids limits our ability to extract valuable cosmological information from their study. In this paper, we address this problem by introducing the spherically compensated cosmic regions, named CoSpheres. Such cosmic regions are identified around local extrema in the density field and admit a unique compensation radius R1 where the internal spherical mass is exactly compensated. Their origin is studied by extending the standard peak model and implementing the compensation condition. Since the compensation radius evolves as the Universe itself, R1(t) ∝ a(t), CoSpheres behave as bubble Universes with fixed comoving volume. Using the spherical collapse model, we reconstruct their profiles with a very high accuracy until z = 0 in N-body simulations. CoSpheres are symmetrically defined and reconstructed for both central maximum (seeding haloes and galaxies) and minimum (identified with cosmic voids). We show that the full non-linear dynamics can be solved analytically around this particular compensation radius, providing useful predictions for cosmology. This formalism highlights original correlations between local extremum and their large-scale cosmic environment. The statistical properties of these spherically compensated cosmic regions and the possibilities to constrain efficiently both cosmology and gravity will be investigated in companion papers.

  6. No Snowball on Habitable Tidally Locked Planets

    NASA Astrophysics Data System (ADS)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  7. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    PubMed

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p < .05). Locking and non-locking double-row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  8. 49 CFR 236.775 - Movement, switch-and-lock.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Movement, switch-and-lock. 236.775 Section 236.775... Movement, switch-and-lock. A device, the complete operation of which performs the three functions of unlocking, operating and locking a switch, movable-point frog or derail. ...

  9. 49 CFR 236.775 - Movement, switch-and-lock.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Movement, switch-and-lock. 236.775 Section 236.775... Movement, switch-and-lock. A device, the complete operation of which performs the three functions of unlocking, operating and locking a switch, movable-point frog or derail. ...

  10. 49 CFR 236.775 - Movement, switch-and-lock.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Movement, switch-and-lock. 236.775 Section 236.775... Movement, switch-and-lock. A device, the complete operation of which performs the three functions of unlocking, operating and locking a switch, movable-point frog or derail. ...

  11. 49 CFR 236.775 - Movement, switch-and-lock.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Movement, switch-and-lock. 236.775 Section 236.775... Movement, switch-and-lock. A device, the complete operation of which performs the three functions of unlocking, operating and locking a switch, movable-point frog or derail. ...

  12. To lock or not to lock patients'rooms: the key to autonomy?

    PubMed

    Shoenfeld, Netta; Ulman, Anne-Marie; Weiss, Mordechai; Strous, Rael D

    2008-10-01

    Many patients with schizophrenia experience prominent negative symptoms. Functional impairment often results in patients who remain in their rooms for most of the day. It has thus become common practice in many psychiatric wards to lock patients' rooms during much of the morning and afternoon hours to encourage participation in ward activities and treatment modalities. Within the context of a quality control evaluation, two self-report surveys were conducted among patients (N=20) and staff members (N=9) in Beer Yaakov, Israel: the first survey was given when the rooms were locked at certain times, and the second survey was given after the rooms had been unlocked for one week. Patients and staff members expressed differing views both before and after the week-long open-door policy (patients enjoyed the policy, whereas many staff did not). Behavior during the period of the open-door policy varied among patients. The authors discuss the ethical grounds of locking doors and whether it is a best practice in keeping with rehabilitation interests.

  13. 12. VIEW OF TYPICAL CELL LOCKING MECHANISM, BUILDING 220 CELL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. VIEW OF TYPICAL CELL LOCKING MECHANISM, BUILDING 220 CELL BLOCK 'A'. THE FACE PLATE OF THE CELL LOCK IS SHOWN REMOVED, EXPOSING THE ELECTROMAGNETIC LOCKING MECHANISM COMPRISING OF 2 MICROSWITCHES FOR LOCK POSITION INDICATION (FRONT LEFT CENTER AND REAR RIGHT CENTER OF PANEL); KEY SLOT MECHANICAL LOCK; LOCK SPRING (UPPER RIGHT OF PANEL); ELECTRIC SOLENOID (BOTTOM RIGHT CORNER OF PANEL); AND MISCELLANEOUS MECHANICAL LINKAGES. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI

  14. Workload Capacity: A Response Time-Based Measure of Automation Dependence.

    PubMed

    Yamani, Yusuke; McCarley, Jason S

    2016-05-01

    An experiment used the workload capacity measure C(t) to quantify the processing efficiency of human-automation teams and identify operators' automation usage strategies in a speeded decision task. Although response accuracy rates and related measures are often used to measure the influence of an automated decision aid on human performance, aids can also influence response speed. Mean response times (RTs), however, conflate the influence of the human operator and the automated aid on team performance and may mask changes in the operator's performance strategy under aided conditions. The present study used a measure of parallel processing efficiency, or workload capacity, derived from empirical RT distributions as a novel gauge of human-automation performance and automation dependence in a speeded task. Participants performed a speeded probabilistic decision task with and without the assistance of an automated aid. RT distributions were used to calculate two variants of a workload capacity measure, COR(t) and CAND(t). Capacity measures gave evidence that a diagnosis from the automated aid speeded human participants' responses, and that participants did not moderate their own decision times in anticipation of diagnoses from the aid. Workload capacity provides a sensitive and informative measure of human-automation performance and operators' automation dependence in speeded tasks. © 2016, Human Factors and Ergonomics Society.

  15. Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    PubMed

    Celicanin, Zarko; Auboiroux, Vincent; Bieri, Oliver; Petrusca, Lorena; Santini, Francesco; Viallon, Magalie; Scheffler, Klaus; Salomir, Rares

    2014-10-01

    Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. MR acquisition consisted of thermometry performed with segmented gradient-recalled echo echo-planar imaging, and a segment-based one-dimensional MR navigator parallel to the main axis of motion to track the organ motion. This tracking information was used in real-time for: (i) prospective motion correction of MR thermometry and (ii) HIFU focal point position lock-on target. Ex vivo experiments were performed on a sheep liver and a turkey pectoral muscle using a motion demonstrator, while in vivo experiments were conducted on two sheep liver. Prospective motion correction of MR thermometry yielded good signal-to-noise ratio (range, 25 to 35) and low geometric distortion due to the use of segmented EPI. HIFU focal point lock-on target yielded isotropic in-plane thermal build-up. The feasibility of in vivo intercostal liver treatment was demonstrated in sheep. The presented method demonstrated in moving phantoms and breathing sheep accurate motion-compensated MR thermometry and precise HIFU focal point lock-on target using only real-time pencil-beam navigator tracking information, making it applicable without any pretreatment data acquisition or organ motion modeling. Copyright © 2013 Wiley Periodicals, Inc.

  16. Clinical Laboratory Automation: A Case Study

    PubMed Central

    Archetti, Claudia; Montanelli, Alessandro; Finazzi, Dario; Caimi, Luigi; Garrafa, Emirena

    2017-01-01

    Background This paper presents a case study of an automated clinical laboratory in a large urban academic teaching hospital in the North of Italy, the Spedali Civili in Brescia, where four laboratories were merged in a unique laboratory through the introduction of laboratory automation. Materials and Methods The analysis compares the preautomation situation and the new setting from a cost perspective, by considering direct and indirect costs. It also presents an analysis of the turnaround time (TAT). The study considers equipment, staff and indirect costs. Results The introduction of automation led to a slight increase in equipment costs which is highly compensated by a remarkable decrease in staff costs. Consequently, total costs decreased by 12.55%. The analysis of the TAT shows an improvement of nonemergency exams while emergency exams are still validated within the maximum time imposed by the hospital. Conclusions The strategy adopted by the management, which was based on re-using the available equipment and staff when merging the pre-existing laboratories, has reached its goal: introducing automation while minimizing the costs. Significance for public health Automation is an emerging trend in modern clinical laboratories with a positive impact on service level to patients and on staff safety as shown by different studies. In fact, it allows process standardization which, in turn, decreases the frequency of outliers and errors. In addition, it induces faster processing times, thus improving the service level. On the other side, automation decreases the staff exposition to accidents strongly improving staff safety. In this study, we analyse a further potential benefit of automation, that is economic convenience. We study the case of the automated laboratory of one of the biggest hospital in Italy and compare the cost related to the pre and post automation situation. Introducing automation lead to a cost decrease without affecting the service level to patients

  17. Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses.

    PubMed

    Almeida, Coral-Ann M; Roberts, Steven G; Laird, Rebecca; McKinnon, Elizabeth; Ahmed, Imran; Pfafferott, Katja; Turley, Joanne; Keane, Niamh M; Lucas, Andrew; Rushton, Ben; Chopra, Abha; Mallal, Simon; John, Mina

    2009-05-15

    The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV, EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, p<0.05). The precision results from the automated system compared favourably with the manual ELISpot and further ensured electronic tracking, increased through-put and reduced turnaround time.

  18. Biomechanics of Far Cortical Locking

    PubMed Central

    Bottlang, Michael; Feist, Florian

    2011-01-01

    The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556

  19. Improved Automatically Locking/Unlocking Orthotic Knee Joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1995-01-01

    Proposed orthotic knee joint improved version of one described in "Automatically Locking/Unlocking Orthotic Knee Joint" (MFS-28633). Locks automatically upon initial application of radial force (wearer's weight) and unlocks automatically, but only when all loads (radial force and bending) relieved. Joints lock whenever wearer applies weight to knee at any joint angle between full extension and 45 degree bend. Both devices offer increased safety and convenience relative to conventional orthotic knee joints.

  20. No Snowball on Habitable Tidally Locked Planets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Checlair, Jade; Abbot, Dorian S.; Menou, Kristen, E-mail: jadecheclair@uchicago.edu

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of globalmore » glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO{sub 2} outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.« less

  1. Opening up Library Automation Software

    ERIC Educational Resources Information Center

    Breeding, Marshall

    2009-01-01

    Throughout the history of library automation, the author has seen a steady advancement toward more open systems. In the early days of library automation, when proprietary systems dominated, the need for standards was paramount since other means of inter-operability and data exchange weren't possible. Today's focus on Application Programming…

  2. How to sharpen your automated tools.

    DOT National Transportation Integrated Search

    2014-12-01

    New programs that claim to make flying more efficient have several things in common, new tasks for pilots, new flight deck displays, automated support tools, changes to ground automation, and displays for air traffic control. Training is one of the t...

  3. Lock-in in forced vibration of a circular cylinder

    NASA Astrophysics Data System (ADS)

    Kumar, Samvit; Navrose, Mittal, Sanjay

    2016-11-01

    The phenomenon of lock-in/synchronization in uniform flow past an oscillating cylinder is investigated via a stabilized finite element method at Re = 100. Computations are carried out for various amplitudes and frequencies of cylinder oscillation to accurately obtain the boundary of the lock-in regime. Results from earlier studies show a significant scatter in the lock-in boundary. The scatter might be an outcome of the difference in data collection or the use of a different criterion for identifying lock-in. A new criterion for lock-in is proposed, wherein the following two conditions are to be satisfied. (i) The most dominant frequency in the power spectrum of lift coefficient matches the frequency of cylinder oscillation (fy) and (ii) other peaks in the power spectrum, if any, are present only at super-harmonics of fy. Utilizing this criterion, three flow regimes are identified on the frequency-amplitude plane: lock-in, transition, and no lock-in. The behaviour of the wake is also investigated by examining the power spectra of the velocity traces at various locations downstream of the cylinder. Wake-lock-in is observed during lock-in. A wake-transition regime is identified wherein the near wake, up to a certain streamwise location, is in a lock-in state while the downstream region is in a desynchronized state. For a fixed fy, the location beyond which the wake is desynchronized moves downstream as the amplitude of oscillation is increased. The proposed criterion for lock-in addresses the wide scatter in the boundary of the lock-in regime among earlier studies. Energy transfer from the fluid to the structure, per cycle of cylinder oscillation, is computed from the data for forced vibration. The data is utilized to generate iso-energy transfer contours in the frequency-amplitude plane. The free vibration response with zero structural damping is found to be in very good agreement with the contour corresponding to zero energy transfer.

  4. PT-symmetric mode-locking.

    PubMed

    Longhi, S

    2016-10-01

    Parity-time (PT) symmetry is one of the most important accomplishments in optics over the past decade. Here the concept of PT mode-locking (ML) of a laser is introduced, in which active phase-locking of cavity axial modes is realized by asymmetric mode coupling in a complex time crystal. PT ML shows a transition from single- to double-pulse emission as the PT symmetry breaking point is crossed. The transition can show a turbulent behavior, depending on a dimensionless modulation parameter that plays the same role as the Reynolds number in hydrodynamic flows.

  5. Locked-wrap fuel rod

    DOEpatents

    Kaplan, Samuel; Chertock, Alan J.; Punches, James R.

    1977-01-01

    A method for spacing fast reactor fuel rods using a wire wrapper improved by orienting the wire-wrapped fuel rods in a unique manner which introduces desirable performance characteristics not attainable by previous wire-wrapped designs. Use of this method in a liquid metal fast breeder reactor results in: (a) improved mechanical performance, (b) improved rod-to-rod contact, (c) reduced steel volume, and (d) improved thermal-hydraulic performance. The method produces a "locked wrap" design which tends to lock the rods together at each of the wire cluster locations.

  6. Research on phase locked loop in optical memory servo system

    NASA Astrophysics Data System (ADS)

    Qin, Liqin; Ma, Jianshe; Zhang, Jianyong; Pan, Longfa; Deng, Ming

    2005-09-01

    Phase locked loop (PLL) is a closed loop automatic control system, which can track the phase of input signal. It widely applies in each area of electronic technology. This paper research the phase locked loop in optical memory servo area. This paper introduces the configuration of digital phase locked loop (PLL) and phase locked servo system, the control theory, and analyses system's stability. It constructs the phase locked loop experiment system of optical disk spindle servo, which based on special chip. DC motor is main object, this system adopted phase locked servo technique and digital signal processor (DSP) to achieve constant linear velocity (CLV) in controlling optical spindle motor. This paper analyses the factors that affect the stability of phase locked loop in spindle servo system, and discusses the affection to the optical disk readout signal and jitter due to the stability of phase locked loop.

  7. Modeling of mode-locked fiber lasers

    NASA Astrophysics Data System (ADS)

    Shaulov, Gary

    This thesis presents the results of analytical and numerical simulations of mode-locked fiber lasers and their components: multiple quantum well saturable absorbers and nonlinear optical loop mirrors. Due to the growing interest in fiber lasers as a compact source of ultrashort pulses there is a need to develop a full understanding of the advantages and limitations of the different mode-locked techniques. The mode-locked fiber laser study performed in this thesis can be used to optimize the design and performance of mode-locked fiber laser systems. A group at Air Force Research Laboratory reported a fiber laser mode-locked by multiple quantum well (MQW) saturable absorber with stable pulses generated as short as 2 ps [21]. The laser cavity incorporates a chirped fiber Bragg grating as a dispersion element; our analysis showed that the laser operates in the soliton regime. Soliton perturbation theory was applied and conditions for stable pulse operation were investigated. Properties of MQW saturable absorbers and their effect on cavity dynamics were studied and the cases of fast and slow saturable absorbers were considered. Analytical and numerical results are in a good agreement with experimental data. In the case of the laser cavity with a regular fiber Bragg grating, the properties of MQW saturable absorbers dominate the cavity dynamics. It was shown that despite the lack of a soliton shaping mechanism, there is a regime in parameter space where stable or quasi-stable solitary waves solutions can exist. Further a novel technique of fiber laser mode-locking by nonlinear polarization rotation was proposed. Polarization rotation of vector solitons was simulated in a birefringent nonlinear optical loop mirror (NOLM) and the switching characteristics of this device was studied. It was shown that saturable absorber-like action of NOLM allows mode-locked operation of the two fiber laser designs. Laser cavity designs were proposed: figure-eight-type and sigma-type cavity.

  8. Optically phase-locked electronic speckle pattern interferometer

    NASA Astrophysics Data System (ADS)

    Moran, Steven E.; Law, Robert; Craig, Peter N.; Goldberg, Warren M.

    1987-02-01

    The design, theory, operation, and characteristics of an optically phase-locked electronic speckle pattern interferometer (OPL-ESPI) are described. The OPL-ESPI system couples an optical phase-locked loop with an ESPI system to generate real-time equal Doppler speckle contours of moving objects from unstable sensor platforms. In addition, the optical phase-locked loop provides the basis for a new ESPI video signal processing technique which incorporates local oscillator phase shifting coupled with video sequential frame subtraction.

  9. Using graphene nano-particle embedded in photonic crystal fiber for evanescent wave mode-locking of fiber laser.

    PubMed

    Lin, Yung-Hsiang; Yang, Chun-Yu; Liou, Jia-Hong; Yu, Chin-Ping; Lin, Gong-Ru

    2013-07-15

    A photonic crystal fiber (PCF) with high-quality graphene nano-particles uniformly dispersed in the hole cladding are demonstrated to passively mode-lock the erbium-doped fiber laser (EDFL) by evanescent-wave interaction. The few-layer graphene nano-particles are obtained by a stabilized electrochemical exfoliation at a threshold bias. These slowly and softly exfoliated graphene nano-particle exhibits an intense 2D band and an almost disappeared D band in the Raman scattering spectrum. The saturable phenomena of the extinction coefficient β in the cladding provides a loss modulation for the intracavity photon intensity by the evanescent-wave interaction. The evanescent-wave mode-locking scheme effectively enlarges the interaction length of saturable absorption with graphene nano-particle to provide an increasing transmittance ΔT of 5% and modulation depth of 13%. By comparing the core-wave and evanescent-wave mode-locking under the same linear transmittance, the transmittance of the graphene nano-particles on the end-face of SMF only enlarges from 0.54 to 0.578 with ΔT = 3.8% and the modulation depth of 10.8%. The evanescent wave interaction is found to be better than the traditional approach which confines the graphene nano-particles at the interface of two SMF patchcords. When enlarging the intra-cavity gain by simultaneously increasing the pumping current of 980-nm and 1480-nm pumping laser diodes (LDs) to 900 mA, the passively mode-locked EDFL shortens its pulsewidth to 650 fs and broadens its spectral linewidth to 3.92 nm. An extremely low carrier amplitude jitter (CAJ) of 1.2-1.6% is observed to confirm the stable EDFL pulse-train with the cladding graphene nano-particle based evanescent-wave mode-locking.

  10. Final Environmental Impact Statement, Rehabilitation of Locks and Dam Number 1, Minneapolis, Minnesota.

    DTIC Science & Technology

    1978-07-01

    sftt ,/’. ,a 2 cs’~ naovigation lock ..vhiCh failed i,? 15/9 sel h" , ’C -- -7 - r I -l n each bock AO ’C squae .16t/,ck f(I yER ILOCA’ p*z :c,,ceie f/cc...Jerrtck s/one parng below apron. � failire Of 5 monoi/ha 1951 r -emoval of fallen guard well and 8 fD~ portion of rock filld crib - tst Zi65.08 -- 8...cut-11-ll Vog re sil wallmnltftiI I0dsee rie lock rLVeC2paiea92/ICk eadtn wi/oo cu AI ii. L_ - r ,^ . _’i eIe / oe n-n - - 1 --- p~bSq toa via cosa

  11. Multifrequency zero-jitter delay-locked loop

    NASA Astrophysics Data System (ADS)

    Efendovich, Avner; Afek, Yachin; Sella, Coby; Bikowsky, Zeev

    1994-01-01

    The approach of an all-digital phase locked loop is used in this delay-locked loop circuit. This design is designated to a system with two processing units, a master CPU and a slave system chip, that share the same bus. It allows maximum utilization of the bus, as the minimal skew between the clocks of the two components significantly reduces idle periods, and also set-up and hold times. Changes in the operating frequency are possible, without falling out of synchronization. Due to the special lead-lag phase detector, the jitter of the clock is zero, when the loop is locked, under any working conditions.

  12. Stable fiber-optic time transfer by active radio frequency phase locking.

    PubMed

    Yin, Feifei; Wu, Zhongle; Dai, Yitang; Ren, Tianpeng; Xu, Kun; Lin, Jintong; Tang, Geshi

    2014-05-15

    In this Letter we demonstrate a fiber link capable of stable time signal transfer utilizing our active long-distance radio frequency (RF) stabilization technology. Taking advantage of the chromatic dispersion in optical fiber, our scheme compensates dynamically the link delay variation by tuning the optical carrier wavelength to phase lock a round-trip RF reference. Since the time signal and the RF reference are carried by the same optical carrier, a highly stable time transfer is achieved at the same time. Experimentally, we demonstrate a stability of the time signal transfer over 50-km fiber with a time deviation of 40 ps at 1-s average and 2.3 ps at 1000-s average. The performance of the RF reference delivery is also tested, with an Allan deviation of 2×10(-15) at 1000-s average. According to our proposal, a simultaneous stable time and frequency transfer is expected.

  13. Binary phase locked loops for Omega receivers

    NASA Technical Reports Server (NTRS)

    Chamberlin, K.

    1974-01-01

    An all-digital phase lock loop (PLL) is considered because of a number of problems inherent in an employment of analog PLL. The digital PLL design presented solves these problems. A single loop measures all eight Omega time slots. Memory-aiding leads to the name of this design, the memory-aided phase lock loop (MAPLL). Basic operating principles are discussed and the superiority of MAPLL over the conventional digital phase lock loop with regard to the operational efficiency for Omega applications is demonstrated.

  14. The strength of polyaxial locking interfaces of distal radius plates.

    PubMed

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  15. Evaluation of fish sampling using rotenone in a navigation lock

    USGS Publications Warehouse

    Margraf, F.J.; Knight, C.T.

    2002-01-01

    Annual sampling in locks with rotenone has been a principal means of assessing fish populations in the commercially navigable portions of the Ohio River. Despite extensive use, sampling in locks with rotenone and interpretation of the data obtained have not been adequately evaluated. The purpose of our study was to determine the degree of inter- and intraseasonal variation in lock samples, estimate correction factors (CFs) for fish recovery rates, and compare lock samples to other fish collections from the navigational pools above and below the lock. Lock samples from all seasons had a greater proportion of pelagic and demersal fish than samples from the navigational pools, which contained greater proportions of littoral species. CF for non-recovery of fish were determined. Spring and summer lock collections yielded several more species and estimates of overall fish biomass were an order of magnitude higher than fall collections. Within season variation between lock samples was relatively low; however, variation in lock samples among seasons was high, equivalent to that seen among the annual samples from the 1980s. Thus, single-season sampling may not be adequate, and fall may be the least preferred season.

  16. Performance Monitoring System: Summary of Lock Statistics. Revision 1.

    DTIC Science & Technology

    1985-12-01

    2751 84 4057 4141 526 798 18 1342 5727 19 5523 3996 4587 8583 1056 1630 35 2721 6536LOCK A DAMI 2 AUXILIARY I Ins NO DATA RECORDD FOR THIS LOCK- " LOCK I...TOTAL (KTOMS) ’ - (AVt OPNP ETC) ’’ ,q [ " ARKANSAS RIVER "" FORRELL LOCK IP 7A/3TRC 9/N83 UPBOUID STATISTICS ISO 53 42 M6 553 356 909 221 41 21 M8

  17. Key-lock colloids in a nematic liquid crystal.

    PubMed

    Silvestre, Nuno M; Tasinkevych, M

    2017-01-01

    The Landau-de Gennes free energy is used to study theoretically the effective interaction of spherical "key" and anisotropic "lock" colloidal particles. We assume identical anchoring properties of the surfaces of the key and of the lock particles, and we consider planar degenerate and perpendicular anchoring conditions separately. The lock particle is modeled as a spherical particle with a spherical dimple. When such a particle is introduced into a nematic liquid crystal, it orients its dimple at an oblique angle θ_{eq} with respect to the far field director n_{∞}. This angle depends on the depth of the dimple. Minimization results show that the free energy of a pair of key and lock particles exhibits a global minimum for the configuration when the key particle is facing the dimple of the lock colloidal particle. The preferred orientation ϕ_{eq} of the key-lock composite doublet relative to n_{∞} is robust against thermal fluctuations. The preferred orientation θ_{eq}^{(2)} of the dimple particle in the doublet is different from the isolated situation. This is related to the "direct" interaction of defects accompanying the key particle with the edge of the dimple. We propose that this nematic-amplified key-lock interaction can play an important role in self-organization and clustering of mixtures of colloidal particles with dimple colloids present.

  18. Digital second-order phase-locked loop

    NASA Technical Reports Server (NTRS)

    Holmes, J. K.; Carl, C. C.; Tagnelia, C. R.

    1975-01-01

    Actual tests with second-order digital phase-locked loop at simulated relative Doppler shift of 1x0.0001 produced phase lock with timing error of 6.5 deg and no appreciable Doppler bias. Loop thus appears to achieve subcarrier synchronization and to remove bias due to Doppler shift in range of interest.

  19. VIEW LOOKING NORTHEAST INTO LOCK 71. NOTE THE SEDIMENT BUILD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW LOOKING NORTHEAST INTO LOCK 71. NOTE THE SEDIMENT BUILD UP. THIS IS BY DESIGN, NOT ONLY ARE THE OLDER LOCKS USED AS AN OVERFLOW SPILLWAY FOR THE CURRENT LOCKS, THEY ARE ALSO USED FOR SEDIMENT AND DEBRIS CONTROL. - New York State Barge Canal, Lockport Locks, Richmond Avenue, Lockport, Niagara County, NY

  20. Phase-locked laser array

    NASA Technical Reports Server (NTRS)

    Botez, Dan (Inventor)

    1987-01-01

    A phase-locked laser array comprises a body of semiconductor material having means for defining a plurality of substantially parallel lasing zones which are spaced an effective distance apart so that the modes of the adjacent lasing zones are phase-locked to one another. One of the array electrodes comprises a plurality of electrical contacts to the body between the lasing zones. These contacts provide an enhanced current density profile and thus an increase in the gain in the regions between the lasing zones so that zero degree phase-shift operation between adjacent lasing zones is achievable.

  1. Response of a lock-in amplifier to noise

    NASA Astrophysics Data System (ADS)

    Van Baak, D. A.; Herold, George

    2014-08-01

    The "lock-in" detection technique can extract, from a possibly noisy waveform, the amplitude of a signal that is synchronous with a known reference signal. This paper examines the effects of input noise on the output of a lock-in amplifier. We present quantitative predictions for the root-mean-square size of the resulting fluctuations and for the spectral density of the noise at the output of a lock-in amplifier. Our results show how a lock-in amplifier can be used to measure the spectral density of noise in the case of a noise-only input signal. Some implications of the theory, familiar and surprising, are tested against experimental data.

  2. CW injection locking for long-term stability of frequency combs

    NASA Astrophysics Data System (ADS)

    Williams, Charles; Quinlan, Franklyn; Delfyett, Peter J.

    2009-05-01

    Harmonically mode-locked semiconductor lasers with external ring cavities offer high repetition rate pulse trains while maintaining low optical linewidth via long cavity storage times. Continuous wave (CW) injection locking further reduces linewidth and stabilizes the optical frequencies. The output can be stabilized long-term with the help of a modified Pound-Drever-Hall feedback loop. Optical sidemode suppression of 36 dB has been shown, as well as RF supermode noise suppression of 14 dB for longer than 1 hour. In addition to the injection locking of harmonically mode-locked lasers requiring an external frequency source, recent work shows the viability of the injection locking technique for regeneratively mode-locked lasers, or Coupled Opto-Electronic Oscillators (COEO).

  3. Improving generalized inverted index lock wait times

    NASA Astrophysics Data System (ADS)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  4. John locke on personal identity.

    PubMed

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  5. Injection locking of optomechanical oscillators via acoustic waves

    NASA Astrophysics Data System (ADS)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-01

    Injection locking is a powerful technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators using similar or other types of oscillators. Here, we present the first demonstration of injection locking of a radiation-pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can easily be implemented on various platforms. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  6. Compensation Effect in Electrical Conduction Process: Effect of Substituent Group

    NASA Astrophysics Data System (ADS)

    Mitra, Bani; Misra, T. N.

    1987-05-01

    The semiconductive properties of Vitamin A acid (Retinoic Acid), a long chain conjugated polyene, were studied as a function of the adsorption of different vapours. A compensation effect was observed in the electrical conduction process; unlike that in Vitamin A alcohol and Vitamin A acetate the compensation temperature was observed on the lower side of the experimental temperature (T0≈285 K). It is concluded that the terminal \\diagdown\\diagupC=0 group conjugated to the polyene chain plays an important role in the manifestation of the compensation effect. Various conduction parameters have been evaluated.

  7. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  8. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  9. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  10. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  11. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  12. Coupled optical resonance laser locking.

    PubMed

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  13. Self-locking mechanical center joint

    NASA Technical Reports Server (NTRS)

    Bush, H. G.; Wallsom, R. E. (Inventor)

    1985-01-01

    A device for connecting, rotating and locking together a pair of structural half columns is described. The device is composed of an identical pair of cylindrical hub assemblies connected at their inner faces by a spring loaded hinge; each hub assembly having a structural half column attached to its outer end. Each hub assembly has a spring loading locking ring member movably attached adjacent to its inner face and includes a latch member for holding the locking ring in a rotated position subject to the force of its spring. Each hub assembly also has a hammer member for releasing the latch on the opposing hub assembly when the hub assemblies are rotated together. The spring loaded hinge connecting the hub assemblies rotates the hub assemblies and attached structural half columns together bringing the inner faces of the opposing hub assemblies into contact with one another.

  14. TECRA: C2 Application of Adaptive Automation Theory

    DTIC Science & Technology

    2010-03-01

    1 TECRA: C2 Application of Adaptive Automation Theory Ewart J. de Visser 1,2 , Melanie LeGoullon 1 , Don Horvath 1 , Gershon Weltman 1 , Amos...Solutions, Inc. 1001 19th St. N Suite 1500 Arlington, VA 22209 910-200-8596 edevisser@percsolutions.com 2 George Mason University 4400 University...to the RVT. Method Twelve students from George Mason University (4 Males and 8 Females) participated in this study and were compensated with

  15. Phase-locked loops. [analog, hybrid, discrete and digital systems

    NASA Technical Reports Server (NTRS)

    Gupta, S. C.

    1974-01-01

    The basic analysis and design procedures are described for the realization of analog phase-locked loops (APLL), hybrid phase-locked loops (HPLL), discrete phase-locked loops, and digital phase-locked loops (DPLL). Basic configurations are diagrammed, and performance curves are given. A discrete communications model is derived and developed. The use of the APLL as an optimum angle demodulator and the Kalman-Bucy approach to APLL design are discussed. The literature in the area of phase-locked loops is reviewed, and an extensive bibliography is given. Although the design of APLLs is fairly well documented, work on discrete, hybrid, and digital PLLs is scattered, and more will have to be done in the future to pinpoint the formal design of DPLLs.

  16. 26 CFR 1.414(q)-1T - Highly compensated employee (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-10Definition of officer and rules on inclusion of officers in highly compensated group. Q&A-11Rules with... rules for permanent and total disability and employee stock ownership plans respectively). (c) Other... pursuant to section 401(c)(1). This rule with respect to the inclusion of certain self-employed individuals...

  17. UPSTREAM LOCK GATE DETAIL AND DOG HOUSE. NOTE ARM AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    UPSTREAM LOCK GATE DETAIL AND DOG HOUSE. NOTE ARM AND GEARING FOR CONTROLLING LOCK GATE. LOOKING WEST SOUTHWEST. - Illinois Waterway, Brandon Road Lock and Dam , 1100 Brandon Road, Joliet, Will County, IL

  18. DOWNSTREAM LOCK GATE DETAIL VIEW WITH DOG HOUSE. NOTE CONTROL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DOWNSTREAM LOCK GATE DETAIL VIEW WITH DOG HOUSE. NOTE CONTROL ARM AND GEAR FOR GATE. LOOKING NORTHWEST. - Illinois Waterway, Dresden Island Lock and Dam , 7521 North Lock Road, Channahon, Will County, IL

  19. Circuit breaker lock out assembly

    DOEpatents

    Gordy, W.T.

    1983-05-18

    A lock out assembly for a circuit breaker which consists of a generally step-shaped unitary base with an aperture in the small portion of the step-shaped base and a roughly S shaped retaining pin which loops through the large portion of the step-shaped base. The lock out assembly is adapted to fit over a circuit breaker with the handle switch projecting through the aperture, and the retaining pin projecting into an opening of the handle switch, preventing removal.

  20. Circuit breaker lock out assembly

    DOEpatents

    Gordy, Wade T.

    1984-01-01

    A lock out assembly for a circuit breaker which consists of a generally step-shaped unitary base with an aperture in the small portion of the step-shaped base and a roughly "S" shaped retaining pin which loops through the large portion of the step-shaped base. The lock out assembly is adapted to fit over a circuit breaker with the handle switch projecting through the aperture, and the retaining pin projecting into an opening of the handle switch, preventing removal.

  1. NMR Spin-Lock Induced Crossing (SLIC) Dispersion and Long-Lived Spin States of Gaseous Propane at Low Magnetic Field (0.05 T)

    PubMed Central

    Barskiy, Danila A.; Salnikov, Oleg G.; Romanov, Alexey S.; Feldman, Matthew A.; Coffey, Aaron M.; Kovtunov, Kirill V.; Koptyug, Igor V.; Chekmenev, Eduard Y.

    2017-01-01

    When parahydrogen reacts with propylene in low magnetic fields (e.g., 0.05 T), the reaction product propane develops an overpopulation of pseudo-singlet nuclear spin states. We studied how the spin-lock induced crossing (SLIC) technique can be used to convert these pseudo-singlet spin states of hyperpolarized gaseous propane into observable magnetization and to detect 1H NMR signal directly at 0.05 T. The theoretical simulation and experimental study of the NMR signal dependence on B1 power (SLIC amplitude) exhibits a well-resolved dispersion, which is induced by the spin-spin couplings in the eight-proton spin system of propane. We also measured the exponential decay time constants (TLLSS or TS) of these pseudo-singlet long-lived spin states (LLSS) by varying the time between hyperpolarized propane production and SLIC detection. We have found that, on average, TS is approximately 3 times longer than the corresponding T1 value under the same conditions in the range of pressures studied (up to 7.6 atm). Moreover, TS may exceed 13 seconds at pressures above 7 atm in the gas phase. These results are in agreement with the previous reports, and they corroborate a great potential of long-lived hyperpolarized propane as an inhalable gaseous contrast agent for lung imaging and as a molecular tracer to study porous media using low-field NMR and MRI. PMID:28152435

  2. NMR Spin-Lock Induced Crossing (SLIC) dispersion and long-lived spin states of gaseous propane at low magnetic field (0.05 T)

    NASA Astrophysics Data System (ADS)

    Barskiy, Danila A.; Salnikov, Oleg G.; Romanov, Alexey S.; Feldman, Matthew A.; Coffey, Aaron M.; Kovtunov, Kirill V.; Koptyug, Igor V.; Chekmenev, Eduard Y.

    2017-03-01

    When parahydrogen reacts with propylene in low magnetic fields (e.g., 0.05 T), the reaction product propane develops an overpopulation of pseudo-singlet nuclear spin states. We studied how the Spin-Lock Induced Crossing (SLIC) technique can be used to convert these pseudo-singlet spin states of hyperpolarized gaseous propane into observable magnetization and to detect 1H NMR signal directly at 0.05 T. The theoretical simulation and experimental study of the NMR signal dependence on B1 power (SLIC amplitude) exhibits a well-resolved dispersion, which is induced by the spin-spin couplings in the eight-proton spin system of propane. We also measured the exponential decay time constants (TLLSS or TS) of these pseudo-singlet long-lived spin states (LLSS) by varying the time between hyperpolarized propane production and SLIC detection. We have found that, on average, TS is approximately 3 times longer than the corresponding T1 value under the same conditions in the range of pressures studied (up to 7.6 atm). Moreover, TS may exceed 13 s at pressures above 7 atm in the gas phase. These results are in agreement with the previous reports, and they corroborate a great potential of long-lived hyperpolarized propane as an inhalable gaseous contrast agent for lung imaging and as a molecular tracer to study porous media using low-field NMR and MRI.

  3. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  4. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  5. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  6. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  7. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  8. LOCSET Phase Locking: Operation, Diagnostics, and Applications

    NASA Astrophysics Data System (ADS)

    Pulford, Benjamin N.

    The aim of this dissertation is to discuss the theoretical and experimental work recently done with the Locking of Optical Coherence via Single-detector Electronic-frequency Tagging (LOCSET) phase locking technique developed and employed here are AFRL. The primary objectives of this effort are to detail the fundamental operation of the LOCSET phase locking technique, recognize the conditions in which the LOCSET control electronics optimally operate, demonstrate LOCSET phase locking with higher channel counts than ever before, and extend the LOCSET technique to correct for low order, atmospherically induced, phase aberrations introduced to the output of a tiled array of coherently combinable beams. The experimental work performed for this effort resulted in the coherent combination of 32 low power optical beams operating with unprecedented LOCSET phase error performance of lambda/71 RMS in a local loop beam combination configuration. The LOCSET phase locking technique was also successfully extended, for the first time, into an Object In the Loop (OIL) configuration by utilizing light scattered off of a remote object as the optical return signal for the LOCSET phase control electronics. Said LOCSET-OIL technique is capable of correcting for low order phase aberrations caused by atmospheric turbulence disturbances applied across a tiled array output.

  9. Automated Algorithm for J-Tpeak and Tpeak-Tend Assessment of Drug-Induced Proarrhythmia Risk

    DOE PAGES

    Johannesen, Lars; Vicente, Jose; Hosseini, Meisam; ...

    2016-12-30

    Prolongation of the heart rate corrected QT (QTc) interval is a sensitive marker of torsade de pointes risk; however it is not specific as QTc prolonging drugs that block inward currents are often not associated with torsade. Recent work demonstrated that separate analysis of the heart rate corrected J-T peakc (J-T peakc) and T peak-T end intervals can identify QTc prolonging drugs with inward current block and is being proposed as a part of a new cardiac safety paradigm for new drugs (the “CiPA” initiative). In this work, we describe an automated measurement methodology for assessment of the J-T peakcmore » and T peak-T end intervals using the vector magnitude lead. The automated measurement methodology was developed using data from one clinical trial and was evaluated using independent data from a second clinical trial. Comparison between the automated and the prior semi-automated measurements shows that the automated algorithm reproduces the semi-automated measurements with a mean difference of single-deltas <1 ms and no difference in intra-time point variability (p for all > 0.39). In addition, the time-profile of the baseline and placebo-adjusted changes are within 1 ms for 63% of the time-points (86% within 2 ms). Importantly, the automated results lead to the same conclusions about the electrophysiological mechanisms of the studied drugs. We have developed an automated algorithm for assessment of J-T peakc and T peak-T end intervals that can be applied in clinical drug trials. Under the CiPA initiative this ECG assessment would determine if there are unexpected ion channel effects in humans compared to preclinical studies. In conclusion, the algorithm is being released as open-source software.« less

  10. Automated Algorithm for J-Tpeak and Tpeak-Tend Assessment of Drug-Induced Proarrhythmia Risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johannesen, Lars; Vicente, Jose; Hosseini, Meisam

    Prolongation of the heart rate corrected QT (QTc) interval is a sensitive marker of torsade de pointes risk; however it is not specific as QTc prolonging drugs that block inward currents are often not associated with torsade. Recent work demonstrated that separate analysis of the heart rate corrected J-T peakc (J-T peakc) and T peak-T end intervals can identify QTc prolonging drugs with inward current block and is being proposed as a part of a new cardiac safety paradigm for new drugs (the “CiPA” initiative). In this work, we describe an automated measurement methodology for assessment of the J-T peakcmore » and T peak-T end intervals using the vector magnitude lead. The automated measurement methodology was developed using data from one clinical trial and was evaluated using independent data from a second clinical trial. Comparison between the automated and the prior semi-automated measurements shows that the automated algorithm reproduces the semi-automated measurements with a mean difference of single-deltas <1 ms and no difference in intra-time point variability (p for all > 0.39). In addition, the time-profile of the baseline and placebo-adjusted changes are within 1 ms for 63% of the time-points (86% within 2 ms). Importantly, the automated results lead to the same conclusions about the electrophysiological mechanisms of the studied drugs. We have developed an automated algorithm for assessment of J-T peakc and T peak-T end intervals that can be applied in clinical drug trials. Under the CiPA initiative this ECG assessment would determine if there are unexpected ion channel effects in humans compared to preclinical studies. In conclusion, the algorithm is being released as open-source software.« less

  11. Experimental implementation of phase locking in a nonlinear interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn; Marino, A. M.

    2015-09-21

    Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in suchmore » a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.« less

  12. 14 CFR 33.92 - Rotor locking tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Rotor locking tests. 33.92 Section 33.92 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.92 Rotor locking tests. If continued...

  13. 14 CFR 33.92 - Rotor locking tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Rotor locking tests. 33.92 Section 33.92 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.92 Rotor locking tests. If continued...

  14. 14 CFR 33.92 - Rotor locking tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Rotor locking tests. 33.92 Section 33.92 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.92 Rotor locking tests. If continued...

  15. 14 CFR 33.92 - Rotor locking tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Rotor locking tests. 33.92 Section 33.92 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.92 Rotor locking tests. If continued...

  16. External Tank (ET) Bipod Fitting Bolted Attachment Locking Insert Performance

    NASA Technical Reports Server (NTRS)

    Larsen, Curtis E.; Wilson, Tim R.; Elliott, Kenny B.; Raju, Ivatury S.; McManamen, John

    2008-01-01

    Following STS-107, the External Tank (ET) Project implemented corrective actions and configuration changes at the ET bipod fitting. Among the corrective actions, the existing bolt lock wire which provided resistance to potential bolt rotation was removed. The lock wire removal was because of concerns with creating voids during foam application and potential for lock wire to become debris. The bolts had been previously lubricated to facilitate assembly but, because of elimination of the lock wire, the ET Project wanted to enable the locking feature of the insert. Thus, the lubrication was removed from bolt threads and instead applied to the washer under the bolt head. Lubrication is necessary to maximize joint pre-load while remaining within the bolt torque specification. The locking feature is implemented by thread crimping in at four places in the insert. As the bolt is torqued into the insert the bolt threads its way past the crimped parts of the insert. This provides the locking of the bolt, as torque is required to loosen the joint after clamping.

  17. A Digital Phase Lock Loop for an External Cavity Diode Laser

    NASA Astrophysics Data System (ADS)

    Wang, Xiao-Long; Tao, Tian-Jiong; Cheng, Bing; Wu, Bin; Xu, Yun-Fei; Wang, Zhao-Ying; Lin, Qiang

    2011-08-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems.

  18. An analytical and experimental study of injection-locked two-port oscillators

    NASA Technical Reports Server (NTRS)

    Freeman, Jon C.; Downey, Alan N.

    1987-01-01

    A Ku-band IMPATT oscillator with two distinct output power ports was injection-locked alternately at both ports. The transmission locking bandwidth was nearly the same for either port. The lower free running power port had a reflection locking bandwidth that was narrower than its transmission locking one. Just the opposite was found at the other port. A detailed analytical model for two-port injection-locked oscillators is presented, and its results agree quite well with the experiments. A critique of the literature on this topic is included to clear up misconceptions and errors. It is concluded that two-port injection-locked oscillators may prove useful in certain communication systems.

  19. Mutual friction in a cold color-flavor-locked superfluid and r-mode instabilities in compact stars.

    PubMed

    Mannarelli, Massimo; Manuel, Cristina; Sa'd, Basil A

    2008-12-12

    Dissipative processes acting in rotating neutron stars are essential in preventing the growth of the r-mode instability. We estimate the damping time of r modes of a hypothetical compact quark star made up by color-flavor-locked quark matter at a temperature T < or approximately 0.01 MeV. The dissipation that we consider is due to the mutual friction force between the normal and the superfluid component arising from the elastic scattering of phonons with quantized vortices. This process is the dominant one for temperatures T < or approximately 0.01 MeV, where the mean free path of phonons due to their self-interactions is larger than the radius of the star. We find that r-mode oscillations are efficiently damped by this mechanism for pulsars rotating at frequencies of the order of 1 Hz at most. Our analysis rules out the possibility that cold pulsars rotating at higher frequencies are entirely made up by color-flavor-locked quark matter.

  20. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    PubMed

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p < 0.001). Fewer patients required postoperative MMF in group A. Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  1. Phase-locked loops. [in analog and digital circuits communication system

    NASA Technical Reports Server (NTRS)

    Gupta, S. C.

    1975-01-01

    An attempt to systematically outline the work done in the area of phase-locked loops which are now used in modern communication system design is presented. The analog phase-locked loops are well documented in several books but discrete, analog-digital, and digital phase-locked loop work is scattered. Apart from discussing the various analysis, design, and application aspects of phase-locked loops, a number of references are given in the bibliography.

  2. Preliminary results toward injection locking of an incoherent laser array

    NASA Technical Reports Server (NTRS)

    Daher, J.

    1986-01-01

    The preliminary results of phase locking an incoherent laser array to a master source in an attempt to achieve coherent operation are presented. The techniques necessary to demonstrate phase locking are described along with some topics for future consideration. As expected, the results obtained suggest that injection locking of an array, where the spacing between adjacent longitudinal modes of its elements is significantly larger than the locking bandwidth, may not be feasible.

  3. Shear-strain energy rate distribution caused by the interplate locking along the Nankai Trough, southwest Japan: An integration analysis using stress tensor inversion and slip deficit inversion

    NASA Astrophysics Data System (ADS)

    Saito, T.; Noda, A.; Yoshida, K.; Tanaka, S.

    2017-12-01

    In the Nankai Trough, southwest Japan, the Philippine Sea Plate descends beneath the Eurasian plate. The locking, or the slip deficit, on the plate interface causes stress fluctuation in the inland area. The interplate locking does not always result in stress accumulation but also causes stress release. The stress increase/decrease is not determined only from the stress fluctuation but also depends on the background stress, in particular, its orientation. This study proposes a method to estimate the shear-strain energy increase/decrease distribution caused by the interplate locking. We at first investigated the background stress field in and around the Nankai Trough. The spatial distribution of the principal stress orientations and the stress ratio were estimated by analysis of 130,000 focal mechanisms of small earthquakes (e.g., Yoshida et al. 2015 Tectonophysics). For example, in an area called Chugoku region, the maximum and minimum compression axes were E-W and N-S directions, respectively. We also estimated the slip-deficit rate at the plate interface by analyzing GNSS data and calculated the stress fluctuation due to the deficit (e.g., Noda et al. 2013 GJI). The interplate locking causes the maximum compression in the direction of plate convergence. This is significantly different from the orientations of the background stress characterized by the E-W compressional strike-slip stress regime.. By combining the results of the background stress and the stress fluctuation, we made a map indicating the shear-strain energy change due to the interplate locking. In the Chugoku region, the shear-strain energy decreases due to the interplate locking. This is because the N-S compressional stress caused by the interplate locking compensates the N-S extensional stress in the background. The shear-strain energy increases in some parts of the analyzed areas. By statistically comparing the shear strain energy rate with the seismicity in the inland area, we found that the

  4. All-digital phase-locked loop with 50-cycle lock time suitable for high-performance microprocessors

    NASA Astrophysics Data System (ADS)

    Dunning, Jim; Garcia, Gerald; Lundberg, Jim; Nuckolls, Ed

    1995-04-01

    A frequency-synthesizing, all-digital phase-locked loop (ADPLL) is fully integrated with a 0.5 micron CMOS microprocessor. The ADPLL has a 50-cycle phase lock, has a gain mechanism independent of process, voltage, and temperature, and is immune to input jitter. A digitally-controlled oscillator (DCO) forms the core of the ADPLL and operates from 50 to 550 MHz, running at 4x the reference clock frequency. The DCO has 16 b of binarily weighted control and achieves LSB resolution under 500 fs.

  5. Locking mechanism for orthopedic braces

    NASA Technical Reports Server (NTRS)

    Chao, J. I.; Epps, C. H., Jr.

    1981-01-01

    An orthopedic brace locking mechanism is described which under standing or walking conditions cannot be unlocked, however under sitting conditions the mechanism can be simply unlocked so as to permit bending of the patient's knee. Other features of the device include: (1) the mechanism is rendered operable, and inoperable, dependent upon the relative inclination of the brace with respect to the ground; (2) the mechanism is automatically locked under standing or walking conditions and is manually unlocked under sitting conditions; and (3) the mechanism is light in weight and is relatively small in size.

  6. Skeletal anteroposterior discrepancy and vertical type effects on lower incisor preoperative decompensation and postoperative compensation in skeletal Class III patients.

    PubMed

    Ahn, Hyo-Won; Baek, Seung-Hak

    2011-01-01

    To determine the initial compensation, preoperative decompensation, and postoperative compensation of the lower incisors according to the skeletal anteroposterior discrepancy and vertical type in skeletal Class III patients. The samples consisted of 68 skeletal Class III patients treated with two-jaw surgery and orthodontic treatment. Lateral cephalograms were taken before preoperative orthodontic treatment (T0) and before surgery (T1) and after debonding (T2). According to skeletal anteroposterior discrepancy/vertical type (ANB, criteria  =  -4°; SN-GoMe, criteria  =  35°) at the T0 stage, the samples were allocated into group 1 (severe anteroposterior discrepancy/hypodivergent vertical type, N  =  17), group 2 (moderate anteroposterior discrepancy/hypodivergent vertical type, N  =  17), group 3 (severe anteroposterior discrepancy/hyperdivergent vertical type, N  =  17), or group 4 (moderate anteroposterior discrepancy/hyperdivergent vertical type, N  =  17). After measurement of variables, one-way analysis of variance with Duncan's multiple comparison test, crosstab analysis, and Pearson correlation analysis were performed. At T0, groups 3 and 2 exhibited the most and least compensated lower incisors. In group 2, good preoperative decompensation and considerable postoperative compensation resulted in different values for T0, T1, and T2 (IMPA, T0 < T2 < T1; P < .001). However, group 3 did not show significant changes in IMPA between stages. Therefore, groups 2 and 3 showed different decompensation achievement ratios (P < .05). Group 3 exhibited the worst ratios of decompensation and stability (24% and 6%, respectively, P < .001). Anteroposterior discrepancy/vertical type (ANB: P < .01 at T0 and T1, P < .001 at T2; SN-GoMe: P < .01, all stages) were strongly correlated with relative percentage ratio of IMPA to norm value. Skeletal anteroposterior discrepancy/vertical type results in differences in the amount and pattern of initial

  7. A Novel Secure IoT-Based Smart Home Automation System Using a Wireless Sensor Network.

    PubMed

    Pirbhulal, Sandeep; Zhang, Heye; E Alahi, Md Eshrat; Ghayvat, Hemant; Mukhopadhyay, Subhas Chandra; Zhang, Yuan-Ting; Wu, Wanqing

    2016-12-30

    Wireless sensor networks (WSNs) provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP) to develop the Internet of Things (IoT) for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i) how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii) how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA) based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods.

  8. A Novel Secure IoT-Based Smart Home Automation System Using a Wireless Sensor Network

    PubMed Central

    Pirbhulal, Sandeep; Zhang, Heye; E Alahi, Md Eshrat; Ghayvat, Hemant; Mukhopadhyay, Subhas Chandra; Zhang, Yuan-Ting; Wu, Wanqing

    2016-01-01

    Wireless sensor networks (WSNs) provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP) to develop the Internet of Things (IoT) for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i) how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii) how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA) based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods. PMID:28042831

  9. Observation of Polarization-Locked Vector Solitons in an Optical Fiber

    NASA Astrophysics Data System (ADS)

    Cundiff, S. T.; Collings, B. C.; Akhmediev, N. N.; Soto-Crespo, J. M.; Bergman, K.; Knox, W. H.

    1999-05-01

    We observe polarization-locked vector solitons in a mode-locked fiber laser. Temporal vector solitons have components along both birefringent axes. Despite different phase velocities due to linear birefringence, the relative phase of the components is locked at +/-π/2. The value of +/-π/2 and component magnitudes agree with a simple analysis of the Kerr nonlinearity. These fragile phase-locked vector solitons have been the subject of much theoretical conjecture, but have previously eluded experimental observation.

  10. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  11. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  12. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  13. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  14. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  15. Phase-lock-loop application for fiber optic receiver

    NASA Astrophysics Data System (ADS)

    Ruggles, Stephen L.; Wills, Robert W.

    1991-02-01

    Phase-locked loop circuits are frequently employed in communication systems. In recent years, digital phase-locked loop circuits were utilized in optical communications systems. In an optical transceiver system, the digital phase-locked loop circuit is connected to the output of the receiver to extract a clock signal from the received coded data (NRZ, Bi-Phase, or Manchester). The clock signal is then used to reconstruct or recover the original data from the coded data. A theoretical approach to the design of a digital phase-locked loop circuit operation at 1 and 50 MHz is described. Hardware implementation of a breadboard design to function at 1 MHz and a printed-circuit board designed to function at 50 MHz were assembled using emitter coupled logic (ECL) to verify experimentally the theoretical design.

  16. Active stabilization of a diode laser injection lock.

    PubMed

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-06-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  17. Phase-lock-loop application for fiber optic receiver

    NASA Technical Reports Server (NTRS)

    Ruggles, Stephen L.; Wills, Robert W.

    1991-01-01

    Phase-locked loop circuits are frequently employed in communication systems. In recent years, digital phase-locked loop circuits were utilized in optical communications systems. In an optical transceiver system, the digital phase-locked loop circuit is connected to the output of the receiver to extract a clock signal from the received coded data (NRZ, Bi-Phase, or Manchester). The clock signal is then used to reconstruct or recover the original data from the coded data. A theoretical approach to the design of a digital phase-locked loop circuit operation at 1 and 50 MHz is described. Hardware implementation of a breadboard design to function at 1 MHz and a printed-circuit board designed to function at 50 MHz were assembled using emitter coupled logic (ECL) to verify experimentally the theoretical design.

  18. Development of thermal actuators with multi-locking positions

    NASA Astrophysics Data System (ADS)

    Luo, J. K.; Zhu, Y.; Fu, Y. Q.; Flewitt, A. J.; Spearing, S. M.; Miao, J. M.; Milne, W. I.

    2006-04-01

    To reduce power consumption and operation temperature for micro-thermal actuators, metal-based micro-mechanical locks with multi-locking positions were analyzed and fabricated. The micro-locks consist of two or three U-shaped thermal actuators. The devices were made by a single mask process using electroplated Ni as the active material. Tests showed that the metal based thermal actuators deliver a maximum displacement of ~20µm at a much lower temperature than that of Si-based actuators. However Ni-actuators showed a severe back bending, which increases with increasing applied power. The temperature to initiate the back bending is as low as ~240°C. Back bending increases the distance between the two actuators, and leads to locking function failure. For practical application, Ni-based thermal actuators must be operated below 200°C.

  19. LagLoc - a new surgical technique for locking plate systems.

    PubMed

    Triana, Miguel; Gueorguiev, Boyko; Sommer, Christoph; Stoffel, Karl; Agarwal, Yash; Zderic, Ivan; Helfen, Tobias; Krieg, James C; Krause, Fabian; Knobe, Matthias; Richards, R Geoff; Lenz, Mark

    2018-06-19

    Treatment of oblique and spiral fractures remains challenging. The aim of this study was to introduce and investigate the new LagLoc technique for locked plating with generation of interfragmentary compression, combining the advantages of lag-screw and locking-head-screw techniques. Oblique fracture was simulated in artificial diaphyseal bones, assigned to three groups for plating with a 7-hole locking compression plate. Group I was plated with three locking screws in holes 1, 4 and 7. The central screw crossed the fracture line. In group II the central hole was occupied with a lag screw perpendicular to fracture line. Group III was instrumented applying the LagLoc technique as follows. Hole 4 was predrilled perpendicularly to the plate, followed by overdrilling of the near cortex and insertion of a locking screw whose head was covered by a holding sleeve to prevent temporarily the locking in the plate hole and generate interfragmentary compression. Subsequently, the screw head was released and locked in the plate hole. Holes 1 and 7 were occupied with locking screws. Interfragmentary compression in the fracture gap was measured using pressure sensors. All screws in the three groups were tightened with 4Nm torque. Interfragmentary compression in group I (167 ± 25N) was significantly lower in comparison to groups II (431 ± 21N) and III (379 ± 59N), p≤0.005. The difference in compression between groups II and III remained not significant (p = 0.999). The new LagLoc technique offers an alternative tool to generate interfragmentary compression with the application of locking plates by combining the biomechanical advantages of lag screw and locking screw fixations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. 49 CFR 236.7 - Circuit controller operated by switch-and-lock movement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Circuit controller operated by switch-and-lock... switch-and-lock movement. Circuit controller operated by switch-and-lock movement shall be maintained so... switch is locked. ...

  1. 49 CFR 236.7 - Circuit controller operated by switch-and-lock movement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Circuit controller operated by switch-and-lock... switch-and-lock movement. Circuit controller operated by switch-and-lock movement shall be maintained so... switch is locked. ...

  2. 49 CFR 236.7 - Circuit controller operated by switch-and-lock movement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Circuit controller operated by switch-and-lock... switch-and-lock movement. Circuit controller operated by switch-and-lock movement shall be maintained so... switch is locked. ...

  3. 49 CFR 236.7 - Circuit controller operated by switch-and-lock movement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Circuit controller operated by switch-and-lock... switch-and-lock movement. Circuit controller operated by switch-and-lock movement shall be maintained so... switch is locked. ...

  4. 49 CFR 236.7 - Circuit controller operated by switch-and-lock movement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Circuit controller operated by switch-and-lock... switch-and-lock movement. Circuit controller operated by switch-and-lock movement shall be maintained so... switch is locked. ...

  5. Releasable locking mechanisms

    NASA Technical Reports Server (NTRS)

    Ahmed, Rafiq (Inventor); Wingate, Robert J. (Inventor)

    2005-01-01

    In the aerospace field spacecraft components are held together by separation systems until a specific time when they must be separated or deployed. Customarily a threaded joining bolt engages one of the components to be joined, and a threaded nut is placed on that bolt against the other component so they can be drawn together by a releasable locking assembly. The releasable locking assembly herein includes a plunger having one end coupled to one end of a plunger bolt. The other end is flanged to abut and compress a coil spring when the plunger is advanced toward the interface plane between the two components. When the plunger is so advanced toward the interface plane, the end of the plunger bolt can be connected to the joining bolt. Thus during retraction the joining bolt is drawn to one side of the interface plane by the force of the expanding spring.

  6. Releasable Locking Mechanisms

    NASA Technical Reports Server (NTRS)

    Ahmed, Rafiq (Inventor); Wingate, Robert J. (Inventor)

    2005-01-01

    In the aerospace field spacecraft components are held together by separation systems until a specific time when they must be separated or deployed. Customarily a threaded joining bolt engages one of the components to be joined, and a threaded nut is placed on that bolt against the other component so they can be drawn together by a releasable locking assembly. The releasable locking assembly herein includes a plunger having one end coupled to one end of a plunger bolt. The other end is flanged to abut and compress a coil spring when the plunger is advanced toward the interface plane between the two components. When the plunger is so advanced toward the interface plane, the end of the plunger bolt can be connected to the joining bolt. Thus during retraction the joining bolt is drawn to one side of the interface plane by the force of the expanding spring.

  7. 38 CFR 21.3023 - Nonduplication; pension, compensation, and dependency and indemnity compensation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., compensation, and dependency and indemnity compensation. 21.3023 Section 21.3023 Pensions, Bonuses, and... Nonduplication; pension, compensation, and dependency and indemnity compensation. (a) Child; age 18. A child who... dependency and indemnity compensation based on school attendance must elect whether he or she will receive...

  8. 38 CFR 21.3023 - Nonduplication; pension, compensation, and dependency and indemnity compensation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., compensation, and dependency and indemnity compensation. 21.3023 Section 21.3023 Pensions, Bonuses, and... Nonduplication; pension, compensation, and dependency and indemnity compensation. (a) Child; age 18. A child who... dependency and indemnity compensation based on school attendance must elect whether he or she will receive...

  9. 38 CFR 21.3023 - Nonduplication; pension, compensation, and dependency and indemnity compensation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., compensation, and dependency and indemnity compensation. 21.3023 Section 21.3023 Pensions, Bonuses, and... Nonduplication; pension, compensation, and dependency and indemnity compensation. (a) Child; age 18. A child who... dependency and indemnity compensation based on school attendance must elect whether he or she will receive...

  10. 38 CFR 21.3023 - Nonduplication; pension, compensation, and dependency and indemnity compensation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., compensation, and dependency and indemnity compensation. 21.3023 Section 21.3023 Pensions, Bonuses, and... Nonduplication; pension, compensation, and dependency and indemnity compensation. (a) Child; age 18. A child who... dependency and indemnity compensation based on school attendance must elect whether he or she will receive...

  11. 38 CFR 21.3023 - Nonduplication; pension, compensation, and dependency and indemnity compensation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., compensation, and dependency and indemnity compensation. 21.3023 Section 21.3023 Pensions, Bonuses, and... Nonduplication; pension, compensation, and dependency and indemnity compensation. (a) Child; age 18. A child who... dependency and indemnity compensation based on school attendance must elect whether he or she will receive...

  12. LOCK, DOG HOUSE, CONTROL STATION, DAM GATE, MANEUVER BOAT No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOCK, DOG HOUSE, CONTROL STATION, DAM GATE, MANEUVER BOAT No. 1, AND DAM. NOTE LOWER LOCK GATE IN FOREGROUND. LOOKING NORTH NORTHEAST. - Illinois Waterway, La Grange Lock and Dam, 3/4 mile south of Country 795N at Illinois River, Versailles, Brown County, IL

  13. 9. VIEW NORTH, EXCAVATED LOCK FROM WATER STREET (Numbers painted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. VIEW NORTH, EXCAVATED LOCK FROM WATER STREET (Numbers painted on stones for reconstruction purposes) - Bald Eagle Cross-Cut Canal Lock, North of Water Street along West Branch of Susquehanna River South bank, 500 feet East of Jay Street Bridge, Lock Haven, Clinton County, PA

  14. An X-band phase-locked relativistic backward wave oscillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Y.; Science and Technology on High Power Microwave Laboratory, Mianyang 621900; Li, Z. H.

    2015-08-15

    For the purpose of coherent high power microwave combining at high frequency band, an X-band phase-locked relativistic backward wave oscillator is presented and investigated. The phase-locking of the oscillator is accomplished by modulation of the electron beam before it reaches the oscillator. To produce a bunched beam with an acceptable injected RF power requirement, an overmoded input cavity is employed to provide initial density modulation. And a buncher cavity is introduced to further increase the modulation depth. When the beam enters the oscillator, the modulation depth is enough to lock the frequency and phase of the output microwave generated bymore » the oscillator. Particle-in-cell simulation shows that an input power of 90 kW is sufficient to lock the frequency and phase of 1.5 GW output microwave with locking bandwidth of 60 MHz.« less

  15. Suppressing the relaxation oscillation noise of injection-locked WRC-FPLD for directly modulated OFDM transmission.

    PubMed

    Cheng, Min-Chi; Chi, Yu-Chieh; Li, Yi-Cheng; Tsai, Cheng-Ting; Lin, Gong-Ru

    2014-06-30

    By up-shifting the relaxation oscillation peak and suppressing its relative intensity noise in a weak-resonant-cavity Fabry-Perot laser diode (WRC-FPLD) under intense injection-locking, the directly modulated transmission of optical 16 quadrature amplitude modulation (QAM) orthogonal frequency division multiplexing (OFDM) data-stream is demonstrated. The total bit rate of up to 20 Gbit/s within 5-GHz bandwidth is achieved by using the OFDM subcarrier pre-leveling technique. With increasing the injection-locking power from -12 to -3 dBm, the effective reduction on threshold current of the WRC-FPLD significantly shifts its relaxation oscillation frequency from 5 to 7.5 GHz. This concurrently induces an up-shift of the peak relative intensity noise (RIN) of the WRC-FPLD, and effectively suppresses the background RIN level to -104 dBc/Hz within the OFDM band between 3 and 6 GHz. The enhanced signal-to-noise ratio from 16 to 20 dB leads to a significant reduction of bit-error-rate (BER) of the back-to-back transmitted 16-QAM-OFDM data from 1.3 × 10(-3) to 5 × 10(-5), which slightly degrades to 1.1 × 10(-4) after 25-km single-mode fiber (SMF) transmission. However, the enlarged injection-locking power from -12 to -3 dBm inevitably declines the modulation throughput and increases its negative throughput slope from -0.8 to -1.9 dBm/GHz. After pre-leveling the peak amplitude of the OFDM subcarriers to compensate the throughput degradation of the directly modulated WRC-FPLD, the BER under 25-km SMF transmission can be further improved to 3 × 10(-5) under a receiving power of -3 dBm.

  16. Process Sensitivity, Performance, and Direct Verification Testing of Adhesive Locking Features

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.; Leatherwood, Michael D.; Montoya, Michael D.; Kato, Ken A.; Akers, Ed

    2012-01-01

    Phase I: The use of adhesive locking features or liquid locking compounds (LLCs) (e.g., Loctite) as a means of providing a secondary locking feature has been used on NASA programs since the Apollo program. In many cases Loctite was used as a last resort when (a) self-locking fasteners were no longer functioning per their respective drawing specification, (b) access was limited for removal & replacement, or (c) replacement could not be accomplished without severe impact to schedule. Long-term use of Loctite became inevitable in cases where removal and replacement of worn hardware was not cost effective and Loctite was assumed to be fully cured and working. The NASA Engineering & Safety Center (NESC) and United Space Alliance (USA) recognized the need for more extensive testing of Loctite grades to better understand their capabilities and limitations as a secondary locking feature. These tests, identified as Phase I, were designed to identify processing sensitivities, to determine proper cure time, the correct primer to use on aerospace nutplate, insert and bolt materials such as A286 and MP35N, and the minimum amount of Loctite that is required to achieve optimum breakaway torque values. The .1900-32 was the fastener size tested, due to wide usage in the aerospace industry. Three different grades of Loctite were tested. Results indicate that, with proper controls, adhesive locking features can be successfully used in the repair of locking features and should be considered for design. Phase II: Threaded fastening systems used in aerospace programs typically have a requirement for a redundant locking feature. The primary locking method is the fastener preload and the traditional redundant locking feature is a self-locking mechanical device that may include deformed threads, non-metallic inserts, split beam features, or other methods that impede movement between threaded members. The self-locking resistance of traditional locking features can be directly verified

  17. Locality-Conscious Lock-Free Linked Lists

    NASA Astrophysics Data System (ADS)

    Braginsky, Anastasia; Petrank, Erez

    We extend state-of-the-art lock-free linked lists by building linked lists with special care for locality of traversals. These linked lists are built of sequences of entries that reside on consecutive chunks of memory. When traversing such lists, subsequent entries typically reside on the same chunk and are thus close to each other, e.g., in same cache line or on the same virtual memory page. Such cache-conscious implementations of linked lists are frequently used in practice, but making them lock-free requires care. The basic component of this construction is a chunk of entries in the list that maintains a minimum and a maximum number of entries. This basic chunk component is an interesting tool on its own and may be used to build other lock-free data structures as well.

  18. SU-F-T-533: Study of Dosimetric Properties of Cadmium Free Alloy Used in Compensator Based IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyagi, A; Kaushik, S; Guru Jambheshwar University of Science & Technology, Hisar, Haryana

    Purpose: To study the dosimetric properties of cadmium free alloy which is used in compensator based IMRT. Methods: A mixture of 30% of lead,52% of bismuth and 18% of tin was used to prepare alloy. We prepared slabs of different thicknesses ranging from 0.71 cm to 6.14 cm. Density of alloy was measured by Archimedes’ principle using SI-234 Denver instrument and water as buoyant liquid. Transmission, linear attenuation coefficient (µ), tissue phantom ration (TPR), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter were measured and analyze for different field size and different thickness of compensatormore » for 6 MV photon beam. Measurements were carried out at 100 cm SSD and 160 cm SSD. Results: Density of alloy was found to be 9.5456 gm/cm3. Melting point of alloy is 90–95 °C. For a field size of 10×10 cm2 µ was 0.4253 cm-1 at 100 cm SSD. Calculated TPR was found to be within 3 % of measured TPR. Ds was found to be decreasing with increasing thickness of compensator. 1cm, 1.98 cm and 4.16 cm thick compensator slab decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10cm2 at 100 cm SSD. As field size increases Ds increases for a given compensator thickness. This is due to increase in amount of scattered dose from wider collimator opening. For smaller field size, PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increases from 1 cm to 6.14 cm at a depth of 10 cm in water. For larger field size variation in PDDs is not significant. Conclusion: High degree of modulation can be achieved from this compensator material, which is essential in compensator based IMRT. Dosimetric properties analyzed in this study establish this alloy as a reliable, cost effective, reusable compensator material.« less

  19. Locked-in: the syndrome as depicted in literature.

    PubMed

    Haan, Joost

    2013-01-01

    Protagonists who are locked-in can be found throughout fiction, probably because being locked-in serves as a strong philosophical metaphor for human existence. In this chapter, three protagonists who are locked-in due to physical/medical reasons will be described. The fictitious stories of Noirtier from The Count of Monte Cristo by Alexandre Dumas and that of Madame Raquin from Thérèse Raquin by Émile Zola are followed by the real-life story of Jean-Dominique Bauby's The Diving Bell and the Butterfly. Dumas' Noirtier is considered the first description of the locked-in syndrome in literature, and Madame Raquin appears to be locked-in also, but her description leaves many questions. Bauby's autopathography is chosen from many several similar discourses as it contains cross-references to Noirtier, Dumas' prototype of the syndrome, but also because it is of high literary value. The similarities and remarkable differences between these three case reports of this existentialistically important state of being will be highlighted, with an emphasis on the focus of their narratives. © 2013 Elsevier B.V. All rights reserved.

  20. 46 CFR 95.16-40 - Locked spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Locked spaces. 95.16-40 Section 95.16-40 Shipping COAST... EQUIPMENT Fixed Clean Agent Gas Extinguishing Systems, Details § 95.16-40 Locked spaces. If a space or enclosure containing extinguishing agent supply or controls is lockable, a key to the space or enclosure...

  1. 46 CFR 95.16-40 - Locked spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Locked spaces. 95.16-40 Section 95.16-40 Shipping COAST... EQUIPMENT Fixed Clean Agent Gas Extinguishing Systems, Details § 95.16-40 Locked spaces. If a space or enclosure containing extinguishing agent supply or controls is lockable, a key to the space or enclosure...

  2. 46 CFR 95.16-40 - Locked spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Locked spaces. 95.16-40 Section 95.16-40 Shipping COAST... EQUIPMENT Fixed Clean Agent Gas Extinguishing Systems, Details § 95.16-40 Locked spaces. If a space or enclosure containing extinguishing agent supply or controls is lockable, a key to the space or enclosure...

  3. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    PubMed

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les

  4. Electro-optic fringe locking and photometric tuning using a two-stage Mach-Zehnder lithium niobate waveguide for high-contrast mid-infrared interferometry

    NASA Astrophysics Data System (ADS)

    Martin, Guillermo; Heidmann, Samuel; Rauch, Jean-Yves; Jocou, Laurent; Courjal, Nadège

    2014-03-01

    We present an optimization process to improve the rejection ratio in integrated beam combiners by locking the dark fringe and then monitoring its intensity. The method proposed here uses the electro-optic effect of lithium niobate in order to lock the dark fringe and to real-time balance the photometric flux by means of a two-stage Mach-Zehnder interferometer waveguide. By applying a control voltage on the output Y-junction, we are able to lock the phase and stay in the dark fringe, while an independent second voltage is applied on the first-stage intensity modulator, to finely balance the photometries. We have obtained a rejection ratio of 4600 (36.6 dB) at 3.39 μm in transverse electric polarization, corresponding to 99.98% fringe contrast, and shown that the system can compensate external phase perturbations (a piston variation of 100 nm) up to around 1 kHz. We also show the preliminary results of this process on wide-band modulation, where a contrast of 38% in 3.25- to 3.65-μm spectral range is obtained. These preliminary results on wide-band need to be optimized, in particular, for reducing scattered light of the device at the Y-junction. We expect this active method to be useful in high-contrast interferometry, in particular, for astronomical spatial projects actually under study.

  5. Physics and Control of Locked Modes in the DIII-D Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volpe, Francesco

    This Final Technical Report summarizes an investigation, carried out under the auspices of the DOE Early Career Award, of the physics and control of non-rotating magnetic islands (“locked modes”) in tokamak plasmas. Locked modes are one of the main causes of disruptions in present tokamaks, and could be an even bigger concern in ITER, due to its relatively high beta (favoring the formation of Neoclassical Tearing Mode islands) and low rotation (favoring locking). For these reasons, this research had the goal of studying and learning how to control locked modes in the DIII-D National Fusion Facility under ITER-relevant conditions ofmore » high pressure and low rotation. Major results included: the first full suppression of locked modes and avoidance of the associated disruptions; the demonstration of error field detection from the interaction between locked modes, applied rotating fields and intrinsic errors; the analysis of a vast database of disruptive locked modes, which led to criteria for disruption prediction and avoidance.« less

  6. Shape Memory Alloy (SMA)-Based Launch Lock

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Bao, Xiaoqi; Bar-Cohen, Yoseph

    2014-01-01

    Most NASA missions require the use of a launch lock for securing moving components during the launch or securing the payload before release. A launch lock is a device used to prevent unwanted motion and secure the controlled components. The current launch locks are based on pyrotechnic, electro mechanically or NiTi driven pin pullers and they are mostly one time use mechanisms that are usually bulky and involve a relatively high mass. Generally, the use of piezoelectric actuation provides high precession nanometer accuracy but it relies on friction to generate displacement. During launch, the generated vibrations can release the normal force between the actuator components allowing shaft's free motion which could result in damage to the actuated structures or instruments. This problem is common to other linear actuators that consist of a ball screw mechanism. The authors are exploring the development of a novel launch lock mechanism that is activated by a shape memory alloy (SMA) material ring, a rigid element and an SMA ring holding flexure. The proposed design and analytical model will be described and discussed in this paper.

  7. 77 FR 23114 - Modification, Revocation and Establishment of Air Traffic Service Routes; Windsor Locks Area; CT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... Traffic Service Routes; Windsor Locks Area; CT AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... coordinate for one point in the description of area navigation (RNAV) route T-300. DATES: Effective date 0901... action under 1 CFR part 51, subject to the annual revision of FAA Order 7400.9 and publication of...

  8. On-Ramp: Improving students' understanding of lock-in amplifiers

    NASA Astrophysics Data System (ADS)

    DeVore, Seth; Singh, Chandralekha; Levy, Jeremy

    2013-03-01

    A lock-in amplifier is a powerful and versatile instrument which is used frequently in condensed matter physics research. However, many students struggle with the basics of a lock-in amplifier and they have difficulty in interpreting the data obtained with this device in diverse applications. To improve students' understanding, we are developing an ``On-Ramp'' tutorial based on physics education research which makes use of a computer simulation of a lock-in amplifier. During the development of the tutorial we interviewed several faculty members and graduate students. The tutorial is based on a field-tested approach in which students realize their difficulties after predicting the outcome of experiments that use a lock-in amplifier; students can check their predictions using simulations. The tutorial then guides students toward a coherent understanding of the basics of a lock-in amplifier. This poster will discuss the development and assessment process. This work is supported by NSF NEB (DMR-1124131) and NSF (PHY-1202909).

  9. Law enforcement officers' opinions about gun locks: anchors on life jackets?

    PubMed Central

    Coyne-Beasley, T; Johnson, R

    2001-01-01

    Objectives—One way law enforcement officers support firearm safety is by promoting the use of gun locks. This investigation examined law enforcement officers' willingness to use gun locks on their own guns, as well as their opinions regarding gun locks in general. Setting—Law enforcement officers from an urban agency in the southern region of the United States. Methods—Free keyed cable gun locks were distributed to all law enforcement officers in one agency who wanted one, and then an anonymous questionnaire survey was conducted about their subsequent use of, and attitudes toward, these devices. Results—About half of the 207 officers collected gun locks (n=103). Nearly three quarters (73%) completed and returned the questionnaire. Two thirds reported that they were not using the gun lock they collected (65%), and over half disagreed that gun lock use should be required (56%). Very few cited any actual or potential technical problems with the device. An important reason given for non-use of gun locks related to being able to access the weapon quickly in case of an emergency. Conclusions—The findings highlight the need for further investigation into law enforcement officers' attitudes toward gun locks, the degree to which their attitudes affect their firearm safety counseling, and the need to develop a gun safety device that can be disengaged quickly. PMID:11565984

  10. Health Insurance Costs and Employee Compensation: Evidence from the National Compensation Survey.

    PubMed

    Anand, Priyanka

    2017-12-01

    This paper examines the relationship between rising health insurance costs and employee compensation. I estimate the extent to which total compensation decreases with a rise in health insurance costs and decompose these changes in compensation into adjustments in wages, non-health fringe benefits, and employee contributions to health insurance premiums. I examine this relationship using the National Compensation Survey, a panel dataset on compensation and health insurance for a sample of establishments across the USA. I find that total hourly compensation reduces by $0.52 for each dollar increase in health insurance costs. This reduction in total compensation is primarily in the form of higher employee premium contributions, and there is no evidence of a change in wages and non-health fringe benefits. These findings show that workers are absorbing at least part of the increase in health insurance costs through lower compensation and highlight the importance of examining total compensation, and not just wages, when examining the relationship between health insurance costs and employee compensation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. A hydraulic assist for a manual skyline lock

    Treesearch

    Cleveland J. Biller

    1977-01-01

    A hydraulic locking mechanism was designed to replace the manual skyline lock on a small standing skyline with gravity carriage. It improved the efficiency of the operation by reducing setup and takedown times and reduced the hazard to the crew.

  12. Natural resources technical support program. Recreational use of Chickamauga Lock, Tennessee, and recreational boaters' perceptions of lock use conflicts. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, M.E.; Hammitt, W.E.; Titre, J.P.

    1992-12-01

    Recreational use of the Chickamauga Lock has more than doubled since 1984, when 3,139 recreational craft used the lock. Forty percent of the total annual use occurs during the month of June. The most common reason for heavy use during the month is to attend special events, although other locks in the Tennessee River Navigation System have also shown an increase in recreational use since 1984. Overall, the study suggests a low level of conflict between recreational and commercial users. Conflict among recreational users appears to be even less of a problem. The biggest source of conflict at the currentmore » time is not the actual delays, but recreational boaters' inability to predict whether the lock will be available for use prior to arriving at the dam. Nearly one half of the boaters indicated that this is a common problem during special events. The Corps can reduce this source of conflict to some extent by using an FM repeater to announce the estimated time of recreational and commercial lockages. A majority of the respondents supported this management alternative. The second most popular management alternative was the construction of a separate lock for commercial traffic.« less

  13. Self-locking washer and method of use

    DOEpatents

    Vodila, James M.; Huyett, John D.

    1991-01-01

    A self-locking washer made of a flat elongated piece of material having a slot in one end of it. The washer is designed so that it can be placed underneath bolts or nuts which are already installed without completely removing the bolt or nut. A method of use of the self-locking washer is also disclosed.

  14. Mutual Injection Locking of Monolithically Integrated Coupled-Cavity DBR Lasers

    DOE PAGES

    Tauke-Pedretti, Anna; Vawter, G. Allen; Skogen, Erik J.; ...

    2011-07-01

    We present a photonic integrated circuit (PIC) composed of two strongly coupled distributed Bragg reflector (DBR) lasers. This PIC utilizes the dynamics of mutual injection locking to increase the relaxation resonance frequency from 3 GHz to beyond 30 GHz. Mutual injection-locking and external injection-locking operation are then compared.

  15. Automated Multi-Atlas Segmentation of Hippocampal and Extrahippocampal Subregions in Alzheimer's Disease at 3T and 7T: What Atlas Composition Works Best?

    PubMed

    Xie, Long; Shinohara, Russell T; Ittyerah, Ranjit; Kuijf, Hugo J; Pluta, John B; Blom, Kim; Kooistra, Minke; Reijmer, Yael D; Koek, Huiberdina L; Zwanenburg, Jaco J M; Wang, Hongzhi; Luijten, Peter R; Geerlings, Mirjam I; Das, Sandhitsu R; Biessels, Geert Jan; Wolk, David A; Yushkevich, Paul A; Wisse, Laura E M

    2018-01-01

    Multi-atlas segmentation, a popular technique implemented in the Automated Segmentation of Hippocampal Subfields (ASHS) software, utilizes multiple expert-labelled images ("atlases") to delineate medial temporal lobe substructures. This multi-atlas method is increasingly being employed in early Alzheimer's disease (AD) research, it is therefore becoming important to know how the construction of the atlas set in terms of proportions of controls and patients with mild cognitive impairment (MCI) and/or AD affects segmentation accuracy. To evaluate whether the proportion of controls in the training sets affects the segmentation accuracy of both controls and patients with MCI and/or early AD at 3T and 7T. We performed cross-validation experiments varying the proportion of control subjects in the training set, ranging from a patient-only to a control-only set. Segmentation accuracy of the test set was evaluated by the Dice similarity coeffiecient (DSC). A two-stage statistical analysis was applied to determine whether atlas composition is linked to segmentation accuracy in control subjects and patients, for 3T and 7T. The different atlas compositions did not significantly affect segmentation accuracy at 3T and for patients at 7T. For controls at 7T, including more control subjects in the training set significantly improves the segmentation accuracy, but only marginally, with the maximum of 0.0003 DSC improvement per percent increment of control subject in the training set. ASHS is robust in this study, and the results indicate that future studies investigating hippocampal subfields in early AD populations can be flexible in the selection of their atlas compositions.

  16. Wavefront correction by target-phase-locking technology in a 500 TW laser facility

    NASA Astrophysics Data System (ADS)

    Wang, D. E.; Dai, W. J.; Zhou, K. N.; Su, J. Q.; Xue, Q.; Yuan, Q.; Zhang, X.; Deng, X. W.; Yang, Y.; Wang, Y. C.; Xie, N.; Sun, L.; Hu, D. X.; Zhu, Q. H.

    2017-03-01

    We demonstrate a novel approach termed target-phase-locking that could improve the entire beam wavefront quality of a 500 TW Nd3+:phosphate glass laser facility. The thermal and static wavefront from front-end to target is corrected by using one deformable mirror that receives feedback from both the focal-spot sensor and wavefront sensor, and only the main laser of the laser system is employed in the correction process, with auxiliary calibration light no longer necessary. As a result, a static focal spot with full width at half maximum of 8.87  ×  5.74 µm is achieved, the thermal wavefront induced by flash-lamp-pumped Nd3+:phosphate glass is compensated with PV from 3.54-0.43 µm, and a dynamic focal spot with intensity exceeding 1020 W cm-2 is precisely predicted at the target with such an approach.

  17. A novel input-parasitic compensation technique for a nanopore-based CMOS DNA detection sensor

    NASA Astrophysics Data System (ADS)

    Kim, Jungsuk

    2016-12-01

    This paper presents a novel input-parasitic compensation (IPC) technique for a nanopore-based complementary metal-oxide-semiconductor (CMOS) DNA detection sensor. A resistive-feedback transimpedance amplifier is typically adopted as the headstage of a DNA detection sensor to amplify the minute ionic currents generated from a nanopore and convert them to a readable voltage range for digitization. But, parasitic capacitances arising from the headstage input and the nanopore often cause headstage saturation during nanopore sensing, thereby resulting in significant DNA data loss. To compensate for the unwanted saturation, in this work, we propose an area-efficient and automated IPC technique, customized for a low-noise DNA detection sensor, fabricated using a 0.35- μm CMOS process; we demonstrated this prototype in a benchtop test using an α-hemolysin ( α-HL) protein nanopore.

  18. Performance of chemical vapor deposition fabricated graphene absorber mirror in Yb3+ : Sc2SiO5 mode-locked laser

    NASA Astrophysics Data System (ADS)

    Cai, Wei; Li, Yaqi; Zhu, Hongtong; Jiang, Shouzhen; Xu, Shicai; Liu, Jie; Zheng, Lihe; Su, Liangbi; Xu, Jun

    2014-12-01

    A reflective graphene saturable absorber mirror (SAM) was successfully fabricated by chemical vapor deposition technology. A stable diode-pumped passively mode-locked Yb3+:Sc2SiO5 laser using a graphene SAM as a saturable absorber was accomplished for the first time. The measured average output power amounts to 351 mW under the absorbed pump power of 12.5 W. Without prisms compensating for dispersion, the minimum pulse duration of 7 ps with a repetition rate of 97 MHz has been obtained at the central wavelength of 1063 nm. The corresponding peak power and the maximum pulse energy were 516 W and 3.6 nJ, respectively.

  19. 1. VIEW OF LOCKS, LOOKING NORTHEAST Photocopy of photograph, ca. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW OF LOCKS, LOOKING NORTHEAST Photocopy of photograph, ca. 1980, courtesy of U.S. Engineer Office, St. Louis, Missouri. Original print is on file at Mississippi River Lock and Dam No. 27 in Granite City, Illinois. - Upper Mississippi River 9-Foot Channel Project, Lock & Dam 27, Granite City, Madison County, IL

  20. Injection Locking Techniques for Spectrum Analysis

    NASA Astrophysics Data System (ADS)

    Gathma, Timothy D.; Buckwalter, James F.

    2011-04-01

    Wideband spectrum analysis supports future communication systems that reconfigure and adapt to the capacity of the spectral environment. While test equipment manufacturers offer wideband spectrum analyzers with excellent sensitivity and resolution, these spectrum analyzers typically cannot offer acceptable size, weight, and power (SWAP). CMOS integrated circuits offer the potential to fully integrate spectrum analysis capability with analog front-end circuitry and digital signal processing on a single chip. Unfortunately, CMOS lacks high-Q passives and wideband resonator tunability that is necessary for heterodyne implementations of spectrum analyzers. As an alternative to the heterodyne receiver architectures, two nonlinear methods for performing wideband, low-power spectrum analysis are presented. The first method involves injecting the spectrum of interest into an array of injection-locked oscillators. The second method employs the closed loop dynamics of both injection locking and phase locking to independently estimate the injected frequency and power.

  1. Phase locking of vortex cores in two coupled magnetic nanopillars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Qiyuan; Liu, Xianyin; Zheng, Qi

    2014-11-15

    Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. Thismore » work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.« less

  2. Time Domain Simulations of Arm Locking in LISA

    NASA Technical Reports Server (NTRS)

    Thorpe, J. I.; Maghami, P.; Livas, Jeff

    2011-01-01

    Arm locking is a technique that has been proposed for reducing laser frequency fluctuations in the Laser Interferometer Space Antenna (LISA). a gravitational-wave observatory sensitive' in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that comprise LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of arm locking including the expected limiting noise sources (shot noise, clock noise. spacecraft jitter noise. and residual laser frequency noise). The effect of imperfect a priori knowledge of the LISA heterodyne frequencies and associated "pulling" of an arm locked laser is included. We find that our implementation meets requirements both on the noise and dynamic range of the laser frequency.

  3. Successful Beam-Beam Tuneshift Compensation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bishofberger, Kip Aaron

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (T EL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operationsmore » with inclusion of the T EL are presented and analyzed. It is shown that the T EL provides a way to shatter the previously inescapable beam-beam limit.« less

  4. Past, Present, Future Erosion at Locke Island

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjornstad, Bruce N.

    2006-08-08

    This report describes and documents the erosion that has occurred along the northeast side of Locke Island over the last 10 to 20 years. The principal cause of this erosion is the massive Locke Island landslide complex opposite the Columbia River along the White Bluffs, which constricts the flow of the river and deflects the river's thalweg southward against the island.

  5. 49 CFR 236.775 - Movement, switch-and-lock.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Movement, switch-and-lock. 236.775 Section 236.775 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Movement, switch-and-lock. A device, the complete operation of which performs the three functions of...

  6. Knee Brace Would Lock And Unlock Automatically

    NASA Technical Reports Server (NTRS)

    Myers, Neill; Forbes, John; Shadoan, Mike; Baker, Kevin

    1995-01-01

    Proposed knee brace designed to aid rehabilitation of person who suffered some muscle damage in leg. Not limited to locking in straight-leg position and, instead, locks at any bend angle. Does not prevent knee from bearing weight. Instead, knee brace allows knee to bear weight and locks only when foot and lower leg bear weight. Thus, brace prevents flexion that wearer desired to prevent but could not prevent because of weakened muscles. Knee bends freely to exercise knee-related muscles. Knee brace strapped at upper end to leg above knee, and anchored at lower end by stirrup under foot. Joint mechanism (identical mechanisms used in left and right assemblies) allows knee joint to flex freely except when weight applied to heel.

  7. Safety lock-out device for electrical appliances

    DOEpatents

    Cliff, Jr., Paul L.

    1996-01-01

    A safety lock-out device prevents the insertion of an electrical power cord into an electrical power cord receptacle of an electrical appliance. The devise comprises a mounting plate fastened to the appliance and a cover plate hingedly attached to the appliance. The cover plate is movable between a first position and a second position such that, in the first position, the cover plate covers and prevents insertion of a power cord into the appliance receptacle. In said second position, the appliance receptacle is uncovered to permit insertion of a power cord into the receptacle. Extending a lock shank through aligned openings formed in flange members extending from the mounting plate and the cover plate locks the cover plate in the first position.

  8. Safety lock-out device for electrical appliances

    DOEpatents

    Cliff, P.L. Jr.

    1996-07-09

    A safety lock-out device prevents the insertion of an electrical power cord into an electrical power cord receptacle of an electrical appliance. The device comprises a mounting plate fastened to the appliance and a hinged cover plate attached to the appliance. The cover plate is movable between a first position and a second position such that, in the first position, the cover plate covers and prevents insertion of a power cord into the appliance receptacle. In said second position, the appliance receptacle is uncovered to permit insertion of a power cord into the receptacle. Extending a lock shank through aligned openings formed in flange members extending from the mounting plate, the cover plate locks the cover plate in the first position. 15 figs.

  9. 38 CFR 3.351 - Special monthly dependency and indemnity compensation, death compensation, pension and spouse's...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. 3.351..., Compensation, and Dependency and Indemnity Compensation Ratings for Special Purposes § 3.351 Special monthly dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. (a...

  10. 38 CFR 3.351 - Special monthly dependency and indemnity compensation, death compensation, pension and spouse's...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. 3.351..., Compensation, and Dependency and Indemnity Compensation Ratings for Special Purposes § 3.351 Special monthly dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. (a...

  11. 38 CFR 3.351 - Special monthly dependency and indemnity compensation, death compensation, pension and spouse's...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. 3.351..., Compensation, and Dependency and Indemnity Compensation Ratings for Special Purposes § 3.351 Special monthly dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. (a...

  12. 38 CFR 3.351 - Special monthly dependency and indemnity compensation, death compensation, pension and spouse's...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. 3.351..., Compensation, and Dependency and Indemnity Compensation Ratings for Special Purposes § 3.351 Special monthly dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. (a...

  13. 38 CFR 3.351 - Special monthly dependency and indemnity compensation, death compensation, pension and spouse's...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. 3.351..., Compensation, and Dependency and Indemnity Compensation Ratings for Special Purposes § 3.351 Special monthly dependency and indemnity compensation, death compensation, pension and spouse's compensation ratings. (a...

  14. Comparison between locked intramedullary nailing and anatomical locking plating in the treatment of displaced clavicular midshaft fractures.

    PubMed

    Zehir, Sinan; Çalbıyık, Murat; Şahin, Ercan; İpek, Deniz

    2016-01-01

    The aim of this study was to compare the results of expandable flexible locked intramedullary nailing and anatomical locking plating in clavicular midshaft fractures. Thirty-three patients (21 male, 12 female) who had displaced fractures and at least 2-cm shortening fixed with expandable flexible locked intramedullary nailing and 38 patients (24 male, 14 female) who underwent anatomical locking plating were recruited. Duration of surgery, incision size, duration of hospital stay, union time, and early and late complications were compared between the groups. Functional results were compared with Constant scoring system. Mean duration of surgery was 32.4±9.1 minutes (range: 20-42 minutes) in the nailing group and 54.1±11.9 minutes (range: 42-70 minutes) in the plating group. The incision was 4.1±0.9 cm (range: 3-5 cm) in the nailing group and 9.5±1.7 cm (range: 7-12 cm) in the plating group. Mean union time was 14.8 weeks (range: 10-24 weeks) in the nailing group and 21.3 weeks (range: 12-33 weeks) in the plating group. Mean duration of hospital stay was 3.6±1.1 days (range: 2-4 days) in the plating group, whereas it was 2.3±0.8 days (range: 1-3 days) in the nailing group. In the plating group, an average of 2.7-mm (range: 0-7 mm) shortening was determined in the clavicles that underwent surgery as compared to the intact clavicles, whereas shortening was 2.3 mm (range: 0-6 mm) in the nailing group. Expandable flexible locked intramedullary nailing can provide more successful outcomes than plating in displaced clavicular midshaft fractures, due to advantages such as shorter union time, lower complication rate, and better cosmetic outcomes.

  15. 2006 Automation Survey: The Systems Are Changing. But School Libraries Aren't

    ERIC Educational Resources Information Center

    Fuller, Daniel

    2006-01-01

    This article presents the findings of the 2006 School Library Journal-San Jose State University Automation Survey. The study takes a close look at the systems that media specialists are using, how they are using them, and what librarians want from their future automation programs. The findings reveal that while respondents were satisfied with…

  16. 45. View along the length of the lock, from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. View along the length of the lock, from the east, looking southwest Oak shooks and carpet protected the resource from visitor traffic. A worker is 'watering down' the lock, to prevent damage from desiccation. - Wabash & Erie Canal, Lock No. 2, 8 miles east of Fort Wayne, adjacent to U.S. Route 24, New Haven, Allen County, IN

  17. Distant view from downstream of lock with southeast machinery house, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Distant view from downstream of lock with southeast machinery house, SF 109, and timber guide wall on left, exterior view of closed lower lock gates and hydro-electric power house and dam in background, view towards west - St. Lucie Canal, St. Lucie Lock No. 1, St. Lucie, Cross State Canal, Okeechobee Intracoastal Waterway, Stuart, Martin County, FL

  18. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  19. T1ρ magnetic resonance: basic physics principles and applications in knee and intervertebral disc imaging.

    PubMed

    Wáng, Yì-Xiáng J; Zhang, Qinwei; Li, Xiaojuan; Chen, Weitian; Ahuja, Anil; Yuan, Jing

    2015-12-01

    T1ρ relaxation time provides a new contrast mechanism that differs from T1- and T2-weighted contrast, and is useful to study low-frequency motional processes and chemical exchange in biological tissues. T1ρ imaging can be performed in the forms of T1ρ-weighted image, T1ρ mapping and T1ρ dispersion. T1ρ imaging, particularly at low spin-lock frequency, is sensitive to B0 and B1 inhomogeneity. Various composite spin-lock pulses have been proposed to alleviate the influence of field inhomogeneity so as to reduce the banding-like spin-lock artifacts. T1ρ imaging could be specific absorption rate (SAR) intensive and time consuming. Efforts to address these issues and speed-up data acquisition are being explored to facilitate wider clinical applications. This paper reviews the T1ρ imaging's basic physic principles, as well as its application for cartilage imaging and intervertebral disc imaging. Compared to more established T2 relaxation time, it has been shown that T1ρ provides more sensitive detection of proteoglycan (PG) loss at early stages of cartilage degeneration. T1ρ has also been shown to provide more sensitive evaluation of annulus fibrosis (AF) degeneration of the discs.

  20. T1ρ magnetic resonance: basic physics principles and applications in knee and intervertebral disc imaging

    PubMed Central

    Zhang, Qinwei; Li, Xiaojuan; Chen, Weitian; Ahuja, Anil; Yuan, Jing

    2015-01-01

    T1ρ relaxation time provides a new contrast mechanism that differs from T1- and T2-weighted contrast, and is useful to study low-frequency motional processes and chemical exchange in biological tissues. T1ρ imaging can be performed in the forms of T1ρ-weighted image, T1ρ mapping and T1ρ dispersion. T1ρ imaging, particularly at low spin-lock frequency, is sensitive to B0 and B1 inhomogeneity. Various composite spin-lock pulses have been proposed to alleviate the influence of field inhomogeneity so as to reduce the banding-like spin-lock artifacts. T1ρ imaging could be specific absorption rate (SAR) intensive and time consuming. Efforts to address these issues and speed-up data acquisition are being explored to facilitate wider clinical applications. This paper reviews the T1ρ imaging’s basic physic principles, as well as its application for cartilage imaging and intervertebral disc imaging. Compared to more established T2 relaxation time, it has been shown that T1ρ provides more sensitive detection of proteoglycan (PG) loss at early stages of cartilage degeneration. T1ρ has also been shown to provide more sensitive evaluation of annulus fibrosis (AF) degeneration of the discs. PMID:26807369

  1. Dark solitons in mode-locked lasers.

    PubMed

    Ablowitz, Mark J; Horikis, Theodoros P; Nixon, Sean D; Frantzeskakis, Dimitri J

    2011-03-15

    Dark soliton formation in mode-locked lasers is investigated by means of a power-energy saturation model that incorporates gain and filtering saturated with energy, and loss saturated with power. It is found that general initial conditions evolve (mode-lock) into dark solitons under appropriate requirements also met in experimental observations. The resulting pulses are essentially dark solitons of the unperturbed nonlinear Schrödinger equation. Notably, the same framework also describes bright pulses in anomalous and normally dispersive lasers.

  2. Self-locking threaded fasteners

    DOEpatents

    Glovan, Ronald J.; Tierney, John C.; McLean, Leroy L.; Johnson, Lawrence L.

    1996-01-01

    A threaded fastener with a shape memory alloy (SMA) coatings on its threads is disclosed. The fastener has special usefulness in high temperature applications where high reliability is important. The SMA coated fastener is threaded into or onto a mating threaded part at room temperature to produce a fastened object. The SMA coating is distorted during the assembly. At elevated temperatures the coating tries to recover its original shape and thereby exerts locking forces on the threads. When the fastened object is returned to room temperature the locking forces dissipate. Consequently the threaded fasteners can be readily disassembled at room temperature but remains securely fastened at high temperatures. A spray technique is disclosed as a particularly useful method of coating of threads of a fastener with a shape memory alloy.

  3. Self-locking threaded fasteners

    DOEpatents

    Glovan, R.J.; Tierney, J.C.; McLean, L.L.; Johnson, L.L.

    1996-01-16

    A threaded fastener with a shape memory alloy (SMA) coatings on its threads is disclosed. The fastener has special usefulness in high temperature applications where high reliability is important. The SMA coated fastener is threaded into or onto a mating threaded part at room temperature to produce a fastened object. The SMA coating is distorted during the assembly. At elevated temperatures the coating tries to recover its original shape and thereby exerts locking forces on the threads. When the fastened object is returned to room temperature the locking forces dissipate. Consequently the threaded fasteners can be readily disassembled at room temperature but remains securely fastened at high temperatures. A spray technique is disclosed as a particularly useful method of coating of threads of a fastener with a shape memory alloy. 13 figs.

  4. Digital phase-lock loop

    NASA Technical Reports Server (NTRS)

    Thomas, Jr., Jess B. (Inventor)

    1991-01-01

    An improved digital phase lock loop incorporates several distinctive features that attain better performance at high loop gain and better phase accuracy. These features include: phase feedback to a number-controlled oscillator in addition to phase rate; analytical tracking of phase (both integer and fractional cycles); an amplitude-insensitive phase extractor; a more accurate method for extracting measured phase; a method for changing loop gain during a track without loss of lock; and a method for avoiding loss of sampled data during computation delay, while maintaining excellent tracking performance. The advantages of using phase and phase-rate feedback are demonstrated by comparing performance with that of rate-only feedback. Extraction of phase by the method of modeling provides accurate phase measurements even when the number-controlled oscillator phase is discontinuously updated.

  5. Testing ultrafast mode-locking at microhertz relative optical linewidth.

    PubMed

    Martin, Michael J; Foreman, Seth M; Schibli, T R; Ye, Jun

    2009-01-19

    We report new limits on the phase coherence of the ultrafast mode-locking process in an octave-spanning Ti:sapphire comb.We find that the mode-locking mechanism correlates optical phase across a full optical octave with less than 2.5 microHZ relative linewidth. This result is at least two orders of magnitude below recent predictions for quantum-limited individual comb-mode linewidths, verifying that the mode-locking mechanism strongly correlates quantum noise across the comb spectrum.

  6. Peak expiratory flow rate of children working in lock factories.

    PubMed

    Singhal, S; Singhal, A; Singh, P N; Agarwal, D K; Gulati, R

    2006-01-01

    Peak expiratory flow rate (PEFR) of 106 children working in different units of lock factory was measured and compared with age and sex matched control group of same socio-economic status children. All the children worked for about ten hours per day. It was observed that there was a significant decrease in PEFR of children working in the different units of lock factories i.e. Hand press, Polishing, Lock fitting, Lock packing units as compared to control group (P>0.001). The reduction percentage of PEFR was maximum in children working in polishing unit (25.48%).

  7. Roller Locking Brake

    NASA Technical Reports Server (NTRS)

    Vranish, John M.

    1993-01-01

    Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

  8. Evolution of the Generic Lock System at Jefferson Lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brian Bevins; Yves Roblin

    2003-10-13

    The Generic Lock system is a software framework that allows highly flexible feedback control of large distributed systems. It allows system operators to implement new feedback loops between arbitrary process variables quickly and with no disturbance to the underlying control system. Several different types of feedback loops are provided and more are being added. This paper describes the further evolution of the system since it was first presented at ICALEPCS 2001 and reports on two years of successful use in accelerator operations. The framework has been enhanced in several key ways. Multiple-input, multiple-output (MIMO) lock types have been added formore » accelerator orbit and energy stabilization. The general purpose Proportional-Integral-Derivative (PID) locks can now be tuned automatically. The generic lock server now makes use of the Proxy IOC (PIOC) developed at Jefferson Lab to allow the locks to be monitored from any EPICS Channel Access aware client. (Previously clients had to be Cdev aware.) The dependency on the Qt XML parser has been replaced with the freely available Xerces DOM parser from the Apache project.« less

  9. Weak-light Phase-locking for LISA

    NASA Technical Reports Server (NTRS)

    McNamara, Paul W.

    2004-01-01

    The long armlengths of the LISA interferometer, and the finite aperture of the telescope, leads to an optical power attenuation of approximately equal to 10(exp -10) of the transmitted to received light. Simple reflection at the end of the arm is therefore not an optimum interferometric design. Instead, a local laser is offset phase-locked to the weak incoming beam, transferring the phase information of the incoming to the outgoing light. This paper reports on an experiment to characterize a weak light phase-locking scheme suitable for LISA in which a diode-pumped, Nd:YAG, non-planar ring oscillator (NPRO) is offset phase-locked to a low power (13pW) frequency stabilised master NPRO. Preliminary results of the relative phase noise of the slave laser shows shot noise limited performance above 0.4 Hz. Excess noise is observed at lower frequencies, most probably due to thermal effects in the optical arrangement and phase sensing electronics.

  10. Laser Metrology Heterodyne Phase-Locked Loop

    NASA Technical Reports Server (NTRS)

    Loya, Frank; Halverson, Peter

    2009-01-01

    A method reduces sensitivity to noise in a signal from a laser heterodyne interferometer. The phase-locked loop (PLL) removes glitches that occur in a zero-crossing detector s output [that can happen if the signal-to-noise ratio (SNR) of the heterodyne signal is low] by the use of an internal oscillator that produces a square-wave signal at a frequency that is inherently close to the heterodyne frequency. It also contains phase-locking circuits that lock the phase of the oscillator to the output of the zero-crossing detector. Because the PLL output is an oscillator signal, it is glitch-free. This enables the ability to make accurate phase measurements in spite of low SNR, creates an immunity to phase error caused by shifts in the heterodyne frequency (i.e. if the target moves causing Doppler shift), and maintains a valid phase even when the signal drops out for brief periods of time, such as when the laser is blocked by a stray object.

  11. Costas loop lock detection in the advanced receiver

    NASA Technical Reports Server (NTRS)

    Mileant, A.; Hinedi, S.

    1989-01-01

    The advanced receiver currently being developed uses a Costas digital loop to demodulate the subcarrier. Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between the samples of the phase-error process. Accounting for this correlation is necessary to achieve the desired lock-detection probability for a given false-alarm rate. Both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the square-law and the absolute-value type detectors. Results are obtained which depict the lock-detection probability as a function of loop signal-to-noise ratio for a given false-alarm rate. The mathematical model and computer simulation show that the square-law detector experiences less degradation due to phase jitter than the absolute-value detector and that the degradation in detector signal-to-noise ratio is more pronounced for square-wave than for sine-wave signals.

  12. Automatic locking knee brace joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  13. Lock-in of a Chiral Soliton Lattice by Itinerant Electrons

    NASA Astrophysics Data System (ADS)

    Okumura, Shun; Kato, Yasuyuki; Motome, Yukitoshi

    2018-03-01

    Chiral magnets often show intriguing magnetic and transport properties associated with their peculiar spin textures. A typical example is a chiral soliton lattice, which is found in monoaxial chiral magnets, such as CrNb3S6 and Yb(Ni1-xCux)3Al9 in an external magnetic field perpendicular to the chiral axis. Here, we theoretically investigate the electronic and magnetic properties in the chiral soliton lattice by a minimal itinerant electron model. Using variational calculations, we find that the period of the chiral soliton lattice can be locked at particular values dictated by the Fermi wave number, in stark contrast to spin-only models. We discuss this behavior caused by the spin-charge coupling as a possible mechanism for the lock-in discovered in Yb(Ni1-xCux)3Al9 [T. Matsumura et al., J. Phys. Soc. Jpn. 86, 124702 (2017)]. We also show that the same mechanism leads to the spontaneous formation of the chiral soliton lattice even in the absence of the magnetic field.

  14. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    PubMed

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  15. Ultra-low noise optical phase-locked loop

    NASA Astrophysics Data System (ADS)

    Ayotte, Simon; Babin, André; Costin, François

    2014-03-01

    The relative phase between two fiber lasers is controlled via a high performance optical phase-locked loop (OPLL). Two parameters are of particular importance for the design: the intrinsic phase noise of the laser (i.e. its linewidth) and a high-gain, low-noise electronic locking loop. In this work, one of the lowest phase noise fiber lasers commercially available was selected (i.e. NP Photonics Rock fiber laser module), with sub-kHz linewidth at 1550.12 nm. However, the fast tuning mechanism of such lasers is through stretching its cavity length with a piezoelectric transducer which has a few 10s kHz bandwidth. To further increase the locking loop bandwidth to several MHz, a second tuning mechanism is used by adding a Lithium Niobate phase modulator in the laser signal path. The OPLL is thus divided into two locking loops, a slow loop acting on the laser piezoelectric transducer and a fast loop acting on the phase modulator. The beat signal between the two phase-locked lasers yields a highly pure sine wave with an integrated phase error of 0.0012 rad. This is orders of magnitude lower than similar existing systems such as the Laser Synthesizer used for distribution of photonic local oscillator (LO) for the Atacama Large Millimeter Array radio telescope in Chile. Other applications for ultra-low noise OPLL include coherent power combining, Brillouin sensing, light detection and ranging (LIDAR), fiber optic gyroscopes, phased array antenna and beam steering, generation of LOs for next generation coherent communication systems, coherent analog optical links, terahertz generation and coherent spectroscopy.

  16. [Vestibular compensation studies]. [Vestibular Compensation and Morphological Studies

    NASA Technical Reports Server (NTRS)

    Perachio, Adrian A. (Principal Investigator)

    1996-01-01

    The following topics are reported: neurophysiological studies on MVN neurons during vestibular compensation; effects of spinal cord lesions on VNC neurons during compensation; a closed-loop vestibular compensation model for horizontally canal-related MVN neurons; spatiotemporal convergence in VNC neurons; contributions of irregularly firing vestibular afferents to linear and angular VOR's; application to flight studies; metabolic measures in vestibular neurons; immediate early gene expression following vestibular stimulation; morphological studies on primary afferents, central vestibular pathways, vestibular efferent projection to the vestibular end organs, and three-dimensional morphometry and imaging.

  17. Automated analysis of non-mass-enhancing lesions in breast MRI based on morphological, kinetic, and spatio-temporal moments and joint segmentation-motion compensation technique

    NASA Astrophysics Data System (ADS)

    Hoffmann, Sebastian; Shutler, Jamie D.; Lobbes, Marc; Burgeth, Bernhard; Meyer-Bäse, Anke

    2013-12-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) represents an established method for the detection and diagnosis of breast lesions. While mass-like enhancing lesions can be easily categorized according to the Breast Imaging Reporting and Data System (BI-RADS) MRI lexicon, a majority of diagnostically challenging lesions, the so called non-mass-like enhancing lesions, remain both qualitatively as well as quantitatively difficult to analyze. Thus, the evaluation of kinetic and/or morphological characteristics of non-masses represents a challenging task for an automated analysis and is of crucial importance for advancing current computer-aided diagnosis (CAD) systems. Compared to the well-characterized mass-enhancing lesions, non-masses have no well-defined and blurred tumor borders and a kinetic behavior that is not easily generalizable and thus discriminative for malignant and benign non-masses. To overcome these difficulties and pave the way for novel CAD systems for non-masses, we will evaluate several kinetic and morphological descriptors separately and a novel technique, the Zernike velocity moments, to capture the joint spatio-temporal behavior of these lesions, and additionally consider the impact of non-rigid motion compensation on a correct diagnosis.

  18. VIEW LOOKING SOUTHWEST INTO LOCK 71. NOTE THE CONCRETE WALL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW LOOKING SOUTHWEST INTO LOCK 71. NOTE THE CONCRETE WALL WITH GATE-VALVED INLETS AT THE BOTTOM, BUILT AT THE LOCATION OF THE FORMER LOCK GATES. THE INLETS CONTROL THE VOLUME OF WATER PASSING THROUGH THE SPILLWAY TO MANAGE THE WATER FLOW TO THE DOWNSTREAM PORTION OF THE CANAL. - New York State Barge Canal, Lockport Locks, Richmond Avenue, Lockport, Niagara County, NY

  19. Widely tunable Tm-doped mode-locked all-fiber laser

    PubMed Central

    Yan, Zhiyu; Sun, Biao; Li, Xiaohui; Luo, Jiaqi; Shum, Perry Ping; Yu, Xia; Zhang, Ying; Wang, Qi Jie

    2016-01-01

    We demonstrated a widely tunable Tm-doped mode-locked all-fiber laser, with the widest tunable range of 136 nm, from 1842 to 1978 nm. Nonlinear polarization evolution (NPE) technique is employed to enable mode-locking and the wavelength-tunable operation. The widely tunable range attributes to the NPE-induced transmission modulation and bidirectional pumping mechanism. Such kind of tunable mode-locked laser can find various applications in optical communications, spectroscopy, time-resolved measurement, and among others. PMID:27263655

  20. Effect of ship locking on sediment oxygen uptake in impounded rivers

    NASA Astrophysics Data System (ADS)

    Lorke, A.; McGinnis, D. F.; Maeck, A.; Fischer, H.

    2012-12-01

    In the majority of large river systems, flow is regulated and/or otherwise affected by operational and management activities, such as ship locking. The effect of lock operation on sediment-water oxygen fluxes was studied within a 12.9 km long impoundment at the Saar River (Germany) using eddy-correlation flux measurements. The continuous observations cover a time period of nearly 5 days and 39 individual locking events. Ship locking is associated with the generation of surges propagating back and forth through the impoundment which causes strong variations of near-bed current velocity and turbulence. These wave-induced flow variations cause variations in sediment-water oxygen fluxes. While the mean flux during time periods without lock operation was 0.5 ± 0.1 g m-2 d-1, it increased by about a factor of 2 to 1.0 ± 0.5 g m-2 d-1within time periods with ship locking. Following the daily schedule of lock operations, fluxes are predominantly enhanced during daytime and follow a pronounced diurnal rhythm. The driving force for the increased flux is the enhancement of diffusive transport across the sediment-water interface by bottom-boundary layer turbulence and perhaps resuspension. Additional means by which the oxygen budget of the impoundment is affected by lock-induced flow variations are discussed.

  1. Vector solitons with locked and precessing states of polarization.

    PubMed

    Sergeyev, Sergey V; Mou, Chengbo; Rozhin, Aleksey; Turitsyn, Sergei K

    2012-11-19

    We demonstrate experimentally new families of vector solitons with locked and precessing states of polarization for fundamental and multipulse soliton operations in a carbon nanotube mode-locked fiber laser with anomalous dispersion laser cavity.

  2. Observation of High-Order Polarization-Locked Vector Solitons in a Fiber Laser

    NASA Astrophysics Data System (ADS)

    Tang, D. Y.; Zhang, H.; Zhao, L. M.; Wu, X.

    2008-10-01

    We report on the experimental observation of a new type of polarization-locked vector soliton in a passively mode-locked fiber laser. The vector soliton is characterized by the fact that not only are the two orthogonally polarized soliton components phase-locked, but also one of the components has a double-humped intensity profile. Multiple phase-locked high-order vector solitons with identical soliton parameters and harmonic mode locking of the vector solitons were also obtained in the laser. Numerical simulations confirmed the existence of stable high-order vector solitons in the fiber laser.

  3. Observation of high-order polarization-locked vector solitons in a fiber laser.

    PubMed

    Tang, D Y; Zhang, H; Zhao, L M; Wu, X

    2008-10-10

    We report on the experimental observation of a new type of polarization-locked vector soliton in a passively mode-locked fiber laser. The vector soliton is characterized by the fact that not only are the two orthogonally polarized soliton components phase-locked, but also one of the components has a double-humped intensity profile. Multiple phase-locked high-order vector solitons with identical soliton parameters and harmonic mode locking of the vector solitons were also obtained in the laser. Numerical simulations confirmed the existence of stable high-order vector solitons in the fiber laser.

  4. Motion compensation in digital subtraction angiography using graphics hardware.

    PubMed

    Deuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim

    2006-07-01

    An inherent disadvantage of digital subtraction angiography (DSA) is its sensitivity to patient motion which causes artifacts in the subtraction images. These artifacts could often reduce the diagnostic value of this technique. Automated, fast and accurate motion compensation is therefore required. To cope with this requirement, we first examine a method explicitly designed to detect local motions in DSA. Then, we implement a motion compensation algorithm by means of block matching on modern graphics hardware. Both methods search for maximal local similarity by evaluating a histogram-based measure. In this context, we are the first who have mapped an optimizing search strategy on graphics hardware while paralleling block matching. Moreover, we provide an innovative method for creating histograms on graphics hardware with vertex texturing and frame buffer blending. It turns out that both methods can effectively correct the artifacts in most case, as the hardware implementation of block matching performs much faster: the displacements of two 1024 x 1024 images can be calculated at 3 frames/s with integer precision or 2 frames/s with sub-pixel precision. Preliminary clinical evaluation indicates that the computation with integer precision could already be sufficient.

  5. Control of photon storage time using phase locking.

    PubMed

    Ham, Byoung S

    2010-01-18

    A photon echo storage-time extension protocol is presented by using a phase locking method in a three-level backward propagation scheme, where phase locking serves as a conditional stopper of the rephasing process in conventional two-pulse photon echoes. The backward propagation scheme solves the critical problems of extremely low retrieval efficiency and pi rephasing pulse-caused spontaneous emission noise in photon echo based quantum memories. The physics of the storage time extension lies in the imminent population transfer from the excited state to an auxiliary spin state by a phase locking control pulse. We numerically demonstrate that the storage time is lengthened by spin dephasing time.

  6. Phase-locking of annular-combination CO2 laser

    NASA Astrophysics Data System (ADS)

    Qi, Tingxiang; Chen, Mei; Zhang, Rongzhu; Xiao, Qianyi

    2015-07-01

    A new annular-combination resonator structure adopting the external-injection phase-locking technology is presented theoretically for that the beam quality of stable annular resonator is not satisfying. The phase-locking principle and feasibility are characterized by energy density of injection beam and coupling coefficient. Based on the diffraction theory, output mode of the resonator with phase-locking is deduced and simulated. Results also confirm that injection beam have a good control effect on output mode. The intensity distributions of output beam are studied briefly and indicate that this new resonator which is adaptable to annular gain media can produce high-power laser beam with high quality.

  7. John Locke on madness: redressing the intellectualist bias.

    PubMed

    Charland, Louis C

    2014-06-01

    Locke is famous for defining madness as an intellectual disorder in the realm of ideas. Numerous commentators take this to be his main and only contribution to the history of psychiatry. However, a detailed exegetical review of all the relevant textual evidence suggests that this intellectualist interpretation of Locke's account of madness is both misleading and incomplete. Affective states of various sorts play an important role in that account and are in fact primordial in the determination of human conduct generally. Locke's legacy in this domain must therefore be revised and the intellectualist bias that dominates discussions of his views must be redressed. © The Author(s) 2014.

  8. Mothers' and adolescents' beliefs about risk compensation following HPV vaccination.

    PubMed

    Marlow, Laura A V; Forster, Alice S; Wardle, Jane; Waller, Jo

    2009-05-01

    To examine the prevalence and predictors of the belief that human papillomavirus (HPV) vaccination will result in "risk compensation," that is, will increase risky sexual behavior. Two surveys were carried out: with 332 mothers (Study 1) and 360 adolescent girls (Study 2). The outcome measure was the score on a risk compensation scale tapping beliefs that HPV vaccination would increase risky sexual behavior. Among mothers, those from the lowest income group (F = 4.38, p < .01), from ethnic minority backgrounds (F = 7.41, p < .01), and who did not attend cervical screening (F = 9.96, p < .01), had the highest risk compensation scores. Among adolescents, girls with lower educational attainment (F = 4.14, p < .05), from ethnic minority backgrounds (F = 6.60, p < .001), and who felt themselves to be less sexually experienced than their peers (F = 3.31, p < .05), had the highest scores. Girls showed lower belief in risk compensation in relation to their own behavior (personal compensation) than for "girls in general" (general compensation; t = 13.68, p < .001). Lower knowledge of HPV was associated with higher personal risk compensation beliefs (F = 4.26, p < .05). A significant minority of mothers and adolescents themselves say that HPV vaccination would increase the chance of risky sexual behavior. Because risk compensation beliefs are likely to predict HPV vaccine acceptance, identifying the basis for these beliefs and providing appropriate information and education to parents and adolescents will be vital. Following the introduction of vaccination, it will be important to discover whether risk compensation actually takes place, and every effort should be made to ensure it does not.

  9. Flow Cytometry Data Preparation Guidelines for Improved Automated Phenotypic Analysis.

    PubMed

    Jimenez-Carretero, Daniel; Ligos, José M; Martínez-López, María; Sancho, David; Montoya, María C

    2018-05-15

    Advances in flow cytometry (FCM) increasingly demand adoption of computational analysis tools to tackle the ever-growing data dimensionality. In this study, we tested different data input modes to evaluate how cytometry acquisition configuration and data compensation procedures affect the performance of unsupervised phenotyping tools. An analysis workflow was set up and tested for the detection of changes in reference bead subsets and in a rare subpopulation of murine lymph node CD103 + dendritic cells acquired by conventional or spectral cytometry. Raw spectral data or pseudospectral data acquired with the full set of available detectors by conventional cytometry consistently outperformed datasets acquired and compensated according to FCM standards. Our results thus challenge the paradigm of one-fluorochrome/one-parameter acquisition in FCM for unsupervised cluster-based analysis. Instead, we propose to configure instrument acquisition to use all available fluorescence detectors and to avoid integration and compensation procedures, thereby using raw spectral or pseudospectral data for improved automated phenotypic analysis. Copyright © 2018 by The American Association of Immunologists, Inc.

  10. Control of integrated micro-resonator wavelength via balanced homodyne locking.

    PubMed

    Cox, Jonathan A; Lentine, Anthony L; Trotter, Douglas C; Starbuck, Andrew L

    2014-05-05

    We describe and experimentally demonstrate a method for active control of resonant modulators and filters in an integrated photonics platform. Variations in resonance frequency due to manufacturing processes and thermal fluctuations are corrected by way of balanced homodyne locking. The method is compact, insensitive to intensity fluctuations, minimally disturbs the micro-resonator, and does not require an arbitrary reference to lock. We demonstrate long-term stable locking of an integrated filter to a laser swept over 1.25 THz. In addition, we show locking of a modulator with low bit error rate while the chip temperature is varied from 5 to 60° C.

  11. Tempered Dreams: Alaine Locke as Pluralist and Pragmatist

    ERIC Educational Resources Information Center

    O'Neill, Linda

    2008-01-01

    This essay discusses Alain LeRoy Locke (1885-1954), Professor of Philosophy (Howard University) and examines his experiences, reasoning, and rhetoric as they challenge the accepted notions of race, education, and democracy. As an African American practicing philosophy in a racist nation, Locke also examined value communities and value differences…

  12. 14 CFR 25.679 - Control system gust locks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.679 Control system gust locks. (a) There must be a device to prevent damage to the control surfaces (including tabs... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Control system gust locks. 25.679 Section...

  13. 14 CFR 25.679 - Control system gust locks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.679 Control system gust locks. (a) There must be a device to prevent damage to the control surfaces (including tabs... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Control system gust locks. 25.679 Section...

  14. 14 CFR 25.679 - Control system gust locks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.679 Control system gust locks. (a) There must be a device to prevent damage to the control surfaces (including tabs... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Control system gust locks. 25.679 Section...

  15. 14 CFR 25.679 - Control system gust locks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.679 Control system gust locks. (a) There must be a device to prevent damage to the control surfaces (including tabs... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Control system gust locks. 25.679 Section...

  16. Automated Transmission-Mode Scanning Electron Microscopy (tSEM) for Large Volume Analysis at Nanoscale Resolution

    PubMed Central

    Kuwajima, Masaaki; Mendenhall, John M.; Lindsey, Laurence F.; Harris, Kristen M.

    2013-01-01

    Transmission-mode scanning electron microscopy (tSEM) on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm2 (65.54 µm per side) at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM) system, which were only 66.59 µm2 (8.160 µm per side) at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software, and reliable geometric measurements from RECONSTRUCT™ or Fiji/TrakEM2 software. Axial resolution limits the analysis of small structures contained within a section (∼45 nm). Since this new tSEM is non-destructive, objects within a section can be explored at finer axial resolution in TEM tomography with current methods. Future development of tSEM tomography promises thinner axial resolution producing nearly isotropic voxels and should provide within-section analyses of structures without changing platforms. Brain was the test system given our interest in synaptic connectivity and plasticity; however, the new tSEM system is readily applicable to other biological systems. PMID:23555711

  17. Transient switching control strategy from regenerative braking to anti-lock braking with a semi-brake-by-wire system

    NASA Astrophysics Data System (ADS)

    Li, Liang; Li, Xujian; Wang, Xiangyu; Liu, Yahui; Song, Jian; Ran, Xu

    2016-02-01

    Regenerative braking is an important technology in improving fuel economy of an electric vehicle (EV). However, additional motor braking will change the dynamic characteristics of the vehicle, leading to braking instability, especially when the anti-lock braking system (ABS) is triggered. In this paper, a novel semi-brake-by-wire system, without the use of a pedal simulator and fail-safe device, is proposed. In order to compensate for the hysteretic characteristics of the designed brake system while ensure braking reliability and fuel economy when the ABS is triggered, a novel switching compensation control strategy using sliding mode control is brought forward. The proposed strategy converts the complex coupling braking process into independent control of hydraulic braking and regenerative braking, through which a balance between braking performance, braking reliability, braking safety and fuel economy is achieved. Simulation results show that the proposed strategy is effective and adaptable in different road conditions while the large wheel slip rate is triggered during a regenerative braking course. The research provides a new possibility of low-cost equipment and better control performance for the regenerative braking in the EV and the hybrid EV.

  18. 49 CFR 236.335 - Dogs, stops and trunnions of mechanical locking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Dogs, stops and trunnions of mechanical locking..., AND APPLIANCES Interlocking Rules and Instructions § 236.335 Dogs, stops and trunnions of mechanical locking. Driving pieces, dogs, stops and trunnions shall be rigidly secured to locking bars. Swing dogs...

  19. 49 CFR 236.335 - Dogs, stops and trunnions of mechanical locking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Dogs, stops and trunnions of mechanical locking..., AND APPLIANCES Interlocking Rules and Instructions § 236.335 Dogs, stops and trunnions of mechanical locking. Driving pieces, dogs, stops and trunnions shall be rigidly secured to locking bars. Swing dogs...

  20. 49 CFR 236.335 - Dogs, stops and trunnions of mechanical locking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Dogs, stops and trunnions of mechanical locking..., AND APPLIANCES Interlocking Rules and Instructions § 236.335 Dogs, stops and trunnions of mechanical locking. Driving pieces, dogs, stops and trunnions shall be rigidly secured to locking bars. Swing dogs...