Sample records for t-test results showed

  1. Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA)

    NASA Astrophysics Data System (ADS)

    Bates, E. M.; Birmingham, W. J.; Romero-Talamás, C. A.

    2018-05-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.

  2. Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA).

    PubMed

    Bates, E M; Birmingham, W J; Romero-Talamás, C A

    2018-05-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.

  3. Utility of the T-SPOT®.TB test's borderline category to increase test resolution for results around the cut-off point.

    PubMed

    Rego, Karen; Pereira, Kristen; MacDougall, James; Cruikshank, William

    2018-01-01

    Accurate identification of individuals with TB infection, is required to achieve the WHO's End TB Strategy goals. While there is general acceptance that the T-SPOT.TB test borderline category provides an opportunity to increase test resolution of results around the test cut-off point, this has not been investigated. 645,947 tests were analyzed to determine frequency of borderline results, effect of age and time between tests and associations between subjects' clinical risk factors and retest results. 645,947 tests produced 93.5% negatives, 4% positives, 0.6% invalids, and 1.8% borderlines. Within the borderline results, 5044 were repeated, with 59.2%, 20.0% and 20.2% resolving to negative, positive and borderline, respectively. Age of subject did not affect retest results; however, time between tests indicated that retest resolution occurred with greatest frequency after 90 days. TB risk factors were provided for 2640 subjects and 17% of low risk subjects with a high initial borderline resolved to negative while 27.6% of subjects with high risk and an initial low borderline resolved to positive, suggesting that these subjects could have been inappropriately classified if using a single cut-off point test with no borderline category. This study demonstrates the utility of the T-SPOT.TB test's borderline category to increase test resolution around the test cut-off point. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. NCV Flow Diagnostic Test Results

    NASA Technical Reports Server (NTRS)

    Cappuccio, Mina

    1999-01-01

    There were two objectives for this test. First, was to assess the reasons why there is approximately 1.5 drag counts (cts) discrepancy between measured and computed drag improvement of the Non-linear Cruise Validation (NCV) over the Technology Concept Airplane (TCA) wing body (WB) configurations. The Navier-Stokes (N-S) pre-test predictions from Boeing Commercial Airplane Group (BCAG) show 4.5 drag cts of improvement for NCV over TCA at a lift coefficient (CL) of 0. I at Mach 2.4. The pre-test predictions from Boeing Phantom Works - Long Beach, BPW-LB, show 3.75 drag cts of improvement. BCAG used OVERFLOW and BPW-LB used CFL3D. The first test entry to validate the improvement was held at the NASA Langley Research Center (LARC) UPV;T, test number 1687. The experimental results showed that the drag improvement was only 2.6 cts, not accounting for laminar run and trip drag. This is approximately 1.5 cts less than predicted computationally. In addition to the low Reynolds Number (RN) test, there was a high RN test in the Boeing Supersonic Wind Tunnel (BSWT) of NCV and TCA. BSV@T test 647 showed that the drag improvement of NCV over TCA was also 2.6 cts, but this did account for laminar run and trip drag. Every effort needed to be done to assess if the improvement measured in LaRC UPWT and BSWT was correct. The second objective, once the first objective was met, was to assess the performance increment of NCV over TCA accounting for the associated laminar run and trip drag corrections in LaRC UPWT. We know that the configurations tested have laminar flow on portions of the wing and have trip drag due to the mechanisms used to force the flow to go from laminar to turbulent aft of the transition location.

  5. Low Emissions RQL Flametube Combustor Test Results

    NASA Technical Reports Server (NTRS)

    Chang, Clarence T.; Holdeman, James D.

    2001-01-01

    The overall objective of this test program was to demonstrate and evaluate the capability of the Rich-burn/Quick-mix/Lean-burn (RQL) combustor concept for HSR applications. This test program was in support of the Pratt & Whitney and GE Aircraft Engines HSR low-NOx Combustor Program. Collaborative programs with Parker Hannifin Corporation and Textron Fuel Systems resulted in the development and testing of the high-flow low-NOx rich-burn zone fuel-to-air ratio research fuel nozzles used in this test program. Based on the results obtained in this test program, several conclusions can be made: (1) The RQL tests gave low NOx and CO emissions results at conditions corresponding to HSR cruise. (2) The Textron fuel nozzle design with optimal multiple partitioning of fuel and air circuits shows potential of providing an acceptable uniform local fuel-rich region in the rich burner. (3) For the parameters studied in this test series, the tests have shown T3 is the dominant factor in the NOx formation for RQL combustors. As T3 increases from 600 to 1100 F, EI(NOx) increases approximately three fold. (4) Factors which appear to have secondary influence on NOx formation are P4, T4, infinity(sub rb), V(sub ref,ov). (5) Low smoke numbers were measured for infinity(sub rb) of 2.0 at P4 of 120 psia.

  6. Trillium 360 Seismometer Initial Test Results

    NASA Astrophysics Data System (ADS)

    Bainbridge, Geoffrey; Devanney, Peter; Upadhyaya, Sarvesh

    2017-04-01

    Test results for Trillium 360 show this seismometer can resolve the Peterson New Low Noise Model down to 300 seconds period. This has been confirmed at multiple sites: Pinon Flat (California), Albuquerque Seismological Laboratory (New Mexico) and Nanometrics (Ottawa, Canada). The Pinon Flat deployment captured the March 2, 2016 Mw=7.9 Indonesian event and showed a response coherent with reference sensors including an STS-1 at periods down to 0.0015 Hz. At frequencies below 0.0015 Hz the reference sensors showed a noncoherent spurious response, i.e. noise in the presence of signal, whereas the Trillium 360 was relatively unaffected. Magnetic sensitivity has been measured to be 0.01 m/s^2/T in two independent tests at ASL and Nanometrics. Temperature sensitivity is 3*10^-4 m/s^2/T. This combination of low sensitivity to both magnetic field and temperature is achieved through magnetic shielding which resolves the side effect of magnetic sensitivity in temperature-compensated ferromagnetic spring alloys. The T360 seismometer components are sufficiently miniaturized for deployment in a borehole. This enables low-noise performance even in an urban environment with thick sediments (at Nanometrics, Ottawa) since the seismometer can be emplaced in bedrock below surface sediments and away from surface noise.

  7. Spectrum fatigue testing of T-shaped tension clips

    NASA Astrophysics Data System (ADS)

    Palmberg, Bjoern; Wallstenius, Bengt

    1992-12-01

    An investigation of strain distributions during static loading and crack propagation and fatigue lives under spectrum loading of T-shaped tension clips was carried out. Three slightly different, with respect to geometry, T shaped tension clips made of aluminum alloy 7010-T73651 were studied. The type 1 and 4 test specimens were different only with respect to the web thickness of the clamping end. The type 1 and 2 test specimens were different with repect to milled flat circular countersink around the holes in the type 2 specimens and with respect to the radius between the web and foot. The spectrum fatigue loading consisted of a load sequence representative for the wing root, lower side, of a fighter aircraft. Tests were made at two different load levels for each specimen type. The strain measurements show that the countersink in the type 2 specimens increases the stresses in the fatigue critical region. This is also manifested in the spectrum fatigue life results, where type 2 specimens show the shortest fatigue lives. The strain measurements show that the torque used for the bolts in joining two test specimens or one test specimen and a dummy has a rather large impact on the strain in the fatigue region. The strains decrease with increasing torque. The spectrum fatigue loading resulted in approximately an equal number of flights to obtain a 10.0 mm crack for specimens of type 1 and 4. This suggests that the type 1 configuration is superior since the web thickness is smaller for this type as compared to the type 4 specimens. In other words, the type 4 specimens have an unnecessary oversize of the clamping end web thickness.

  8. 12. Exterior view, showing tank and piping associated with Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Exterior view, showing tank and piping associated with Test Cell 7, Systems Integration Laboratory Building (T-28), looking west. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  9. The Application of Stress-Relaxation Test to Life Assessment of T911/T22 Weld Metal

    NASA Astrophysics Data System (ADS)

    Cao, Tieshan; Zhao, Jie; Cheng, Congqian; Li, Huifang

    2016-03-01

    A dissimilar weld metal was obtained through submerged arc welding of a T911 steel to a T22 steel, and its creep property was explored by stress-relaxation test assisted by some conventional creep tests. The creep rate information of the stress-relaxation test was compared to the minimum and the average creep rates of the conventional creep test. Log-log graph showed that the creep rate of the stress-relaxation test was in a linear relationship with the minimum creep rate of the conventional creep test. Thus, the creep rate of stress-relaxation test could be used in the Monkman-Grant relation to calculate the rupture life. The creep rate of the stress-relaxation test was similar to the average creep rate, and thereby the rupture life could be evaluated by a method of "time to rupture strain." The results also showed that rupture life which was assessed by the Monkman-Grant relation was more accurate than that obtained through the method of "time to rupture strain."

  10. 40 CFR Appendix I to Subpart T - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission Results I Appendix I to Subpart T Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... (CONTINUED) Manufacturer-Run In-Use Testing Program for Heavy-Duty Diesel Engines Pt. 86, Subpt. T, App. I Appendix I to Subpart T—Sample Graphical Summary of NTE Emission Results The following figure shows an...

  11. 40 CFR Appendix I to Subpart T - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emission Results I Appendix I to Subpart T Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... (CONTINUED) Manufacturer-Run In-Use Testing Program for Heavy-Duty Diesel Engines Pt. 86, Subpt. T, App. I Appendix I to Subpart T—Sample Graphical Summary of NTE Emission Results The following figure shows an...

  12. When "t"-Tests or Wilcoxon-Mann-Whitney Tests Won't Do

    ERIC Educational Resources Information Center

    McElduff, Fiona; Cortina-Borja, Mario; Chan, Shun-Kai; Wade, Angie

    2010-01-01

    "t"-Tests are widely used by researchers to compare the average values of a numeric outcome between two groups. If there are doubts about the suitability of the data for the requirements of a "t"-test, most notably the distribution being non-normal, the Wilcoxon-Mann-Whitney test may be used instead. However, although often…

  13. Similarity of scattering rates in metals showing T-linear resistivity.

    PubMed

    Bruin, J A N; Sakai, H; Perry, R S; Mackenzie, A P

    2013-02-15

    Many exotic compounds, such as cuprate superconductors and heavy fermion materials, exhibit a linear in temperature (T) resistivity, the origin of which is not well understood. We found that the resistivity of the quantum critical metal Sr(3)Ru(2)O(7) is also T-linear at the critical magnetic field of 7.9 T. Using the precise existing data for the Fermi surface topography and quasiparticle velocities of Sr(3)Ru(2)O(7), we show that in the region of the T-linear resistivity, the scattering rate per kelvin is well approximated by the ratio of the Boltzmann constant to the Planck constant divided by 2π. Extending the analysis to a number of other materials reveals similar results in the T-linear region, in spite of large differences in the microscopic origins of the scattering.

  14. Primary and acquired EGFR T790M-mutant NSCLC patients identified by routine mutation testing show different characteristics but may both respond to osimertinib treatment.

    PubMed

    Li, Weihua; Qiu, Tian; Guo, Lei; Ling, Yun; Gao, Yibo; Ying, Jianming; He, Jie

    2018-06-01

    Primary EGFR T790M mutation is occasionally identified by routine mutation testing in tyrosine kinase inhibitor (TKI)-naive patients with non-small cell lung cancer (NSCLC). We herein aimed to compare the characteristics of primary and acquired T790M mutations in NSCLC patients, and their response to osimertinib. Using amplification refractory mutation system (ARMS) detection, primary T790M was identified in 0.5% (46/8723) of TKI-naive patients, whereas acquired T790M was detected in 49.7% (71/143) of TKI-relapsed patients. T790M always coexisted with a sensitizing EGFR mutation. Primary T790M more commonly coexisted with L858R, whereas acquired T790M was more likely to coexist with exon 19 deletions. Moreover, next-generation sequencing (NGS) showed that concomitant sensitizing EGFR and primary T790M mutant allele frequencies (MAFs) were highly concordant, but acquired T790M MAFs were significantly lower than the sensitizing EGFR MAFs. Sixteen acquired T790M-mutant patients received osimertinib. The median progression-free survival (PFS) was 8.1 months. Four primary T790M-mutant patients received osimertinib and the median PFS was 8.0 months. Together, our study demonstrates that primary and acquired T790M-mutant patients show distinct differences in some clinical and molecular characteristics, but may both respond to osimertinib treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Tension and Bending Testing of an Integral T-Cap for Stitched Composite Airframe Joints

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Leone, Frank A., Jr.

    2016-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is a structural concept that was developed by The Boeing Company to address the complex structural design aspects associated with a pressurized hybrid wing body aircraft configuration. An important design feature required for assembly is the integrally stitched T-cap, which provides connectivity of the corner (orthogonal) joint between adjacent panels. A series of tests were conducted on T-cap test articles, with and without a rod stiffener penetrating the T-cap web, under tension (pull-off) and bending loads. Three designs were tested, including the baseline design used in large-scale test articles. The baseline had only the manufacturing stitch row adjacent to the fillet at the base of the T-cap web. Two new designs added stitching rows to the T-cap web at either 0.5- or 1.0-inch spacing along the height of the web. Testing was conducted at NASA Langley Research Center to determine the behavior of the T-cap region resulting from the applied loading. Results show that stitching arrests the initial delamination failures so that the maximum strength capability exceeds the load at which the initial delaminations develop. However, it was seen that the added web stitching had very little effect on the initial delamination failure load, but actually decreased the initial delamination failure load for tension loading of test articles without a stiffener passing through the web. Additionally, the added web stitching only increased the maximum load capability by between 1% and 12.5%. The presence of the stiffener, however, did increase the initial and maximum loads for both tension and bending loading as compared to the stringerless baseline design. Based on the results of the few samples tested, the additional stitching in the T-cap web showed little advantage over the baseline design in terms of structural failure at the T-cap web/skin junction for the current test articles.

  16. Aerial shows Stennis test stands

    NASA Image and Video Library

    2004-04-16

    An aerial photo shows the B-1/B-2 Test Stand (foreground), A-2 Test Stand (middle) and A-1 Test Stand (back). The historic stands have been used to test engines used on every manned Apollo and space shuttle mission.

  17. Overview of T.E.S.T. (Toxicity Estimation Software Tool)

    EPA Science Inventory

    This talk provides an overview of T.E.S.T. (Toxicity Estimation Software Tool). T.E.S.T. predicts toxicity values and physical properties using a variety of different QSAR (quantitative structure activity relationship) approaches including hierarchical clustering, group contribut...

  18. Retrospective Review of Treponema pallidum PCR and Serology Results: Are Both Tests Necessary?

    PubMed

    Brischetto, Anna; Gassiep, Ian; Whiley, David; Norton, Robert

    2018-05-01

    There has been a resurgence of syphilis diagnoses in Australia. We investigated whether our Treponema pallidum PCR test provides any additional diagnostic information over syphilis serology (chemiluminescence immunoassay [CMIA], Treponema pallidum particle agglutination [TPPA] assay, and the rapid plasma reagin [RPR] flocculation test). A retrospective audit of all T. pallidum PCR requests that came through our laboratory from January 2010 to June 2017 was conducted; data collected included age, gender, site of swab, and results from T. pallidum PCR, syphilis serology, and herpes simplex virus 1 (HSV-1) and HSV-2 PCRs. A total of 441 T. pallidum PCR tests were performed; on average, 3 T. pallidum PCRs per month were requested in 2011, and this rate increased to 17.2 requests per month in 2017. A total of 323 patients had both T. pallidum PCR and syphilis serology performed, with 67% of swabs taken from the genitals. T. pallidum PCR gave positive results for 61/323 (19%) patients; of these 61 patients, 59 (97%) also had positive syphilis serology results ( T. pallidum PCR sensitivity, 68%; specificity, 99%; positive predictive value, 97%; negative predictive value, 89%). Syphilis serology was positive for 91/323 patients (28%); of these 91 patients, 61 (66%) were also T. pallidum PCR positive (syphilis serology sensitivity, 97%; specificity, 88%; positive predictive value, 60%; negative predictive value, 99%). The Cohen's kappa value was 0.74, indicating substantial agreement between the two tests. Our results show that most patients with positive T. pallidum PCR results also had positive syphilis serology. Therefore, T. pallidum PCR adds little clinical value over serology for the diagnosis of syphilis in certain clinical settings. Copyright © 2018 American Society for Microbiology.

  19. 3. GENERAL VIEW, LOOKING NORTHEAST, SHOWING T1032 IN FOREGROUND ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. GENERAL VIEW, LOOKING NORTHEAST, SHOWING T-1032 IN FOREGROUND ON LEFT. T-1032, T-1031, T-1030 & T-1029 CAN ALSO BE SEEN IN BACKGROUND ON RIGHT. - Fort McCoy, Building No. T-1032, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  20. Coagulation tests show significant differences in patients with breast cancer.

    PubMed

    Tas, Faruk; Kilic, Leyla; Duranyildiz, Derya

    2014-06-01

    Activated coagulation and fibrinolytic system in cancer patients is associated with tumor stroma formation and metastasis in different cancer types. The aim of this study is to explore the correlation of blood coagulation assays for various clinicopathologic factors in breast cancer patients. A total of 123 female breast cancer patients were enrolled into the study. All the patients were treatment naïve. Pretreatment blood coagulation tests including PT, APTT, PTA, INR, D-dimer, fibrinogen levels, and platelet counts were evaluated. Median age of diagnosis was 51 years old (range 26-82). Twenty-two percent of the group consisted of metastatic breast cancer patients. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group except for PT (p<0.001 for all variables except for PT; p=0.08). Elderly age (>50 years) was associated with higher D-dimer levels (p=0.003). Metastatic patients exhibited significantly higher D-dimer values when compared with early breast cancer patients (p=0.049). Advanced tumor stage (T3 and T4) was associated with higher INR (p=0.05) and lower PTA (p=0.025). In conclusion, coagulation tests show significant differences in patients with breast cancer.

  1. SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rusk, B; Fontenot, J

    Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modesmore » using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.« less

  2. The t-test: An Influential Inferential Tool in Chaplaincy and Other Healthcare Research.

    PubMed

    Jankowski, Katherine R B; Flannelly, Kevin J; Flannelly, Laura T

    2018-01-01

    The t-test developed by William S. Gosset (also known as Student's t-test and the two-sample t-test) is commonly used to compare one sample mean on a measure with another sample mean on the same measure. The outcome of the t-test is used to draw inferences about how different the samples are from each other. It is probably one of the most frequently relied upon statistics in inferential research. It is easy to use: a researcher can calculate the statistic with three simple tools: paper, pen, and a calculator. A computer program can quickly calculate the t-test for large samples. The ease of use can result in the misuse of the t-test. This article discusses the development of the original t-test, basic principles of the t-test, two additional types of t-tests (the one-sample t-test and the paired t-test), and recommendations about what to consider when using the t-test to draw inferences in research.

  3. The Toxicity Estimation Software Tool (T.E.S.T.)

    EPA Science Inventory

    The Toxicity Estimation Software Tool (T.E.S.T.) has been developed to estimate toxicological values for aquatic and mammalian species considering acute and chronic endpoints for screening purposes within TSCA and REACH programs.

  4. Brush Seal Performance and Durability Issues Based on T-700 Engine Test Results

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.

    1994-01-01

    The integrity and performance of brush seals have been established. Severe bench and engine tests have shown high initial wear or run-in rates, material smearing at the interface, and bristle and rub-runner wear, but the brush seals did not fail. Short-duration (46 hr) experimental T-700 engine testing of the compressor discharge seal established over 1-percent engine performance gain (brush versus labyrinth). Long-term gains were established only as leakage comparisons, with the brush at least 20 percent better at controlling leakage. Long-term materials issues, such as wear and ultimately seal life, remain to be resolved. Future needs are cited for materials and analysis tools that account for heat generation, thermomechanical behavior, and tribological pairing to enable original equipment manufacturers to design high-temperature, high-surface-speed seals with confidence.

  5. 4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING EMERGENCY SHOWER, AND EYEWASH, AND OBSERVATION WINDOW. STORAGE TANKS ON ROOF. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  6. Test 6, Test 7, and Gas Standard Analysis Results

    NASA Technical Reports Server (NTRS)

    Perez, Horacio, III

    2007-01-01

    This viewgraph presentation shows results of analyses on odor, toxic off gassing and gas standards. The topics include: 1) Statistical Analysis Definitions; 2) Odor Analysis Results NASA Standard 6001 Test 6; 3) Toxic Off gassing Analysis Results NASA Standard 6001 Test 7; and 4) Gas Standard Results NASA Standard 6001 Test 7;

  7. High-efficiency L-band T/R Module: Development Results

    NASA Technical Reports Server (NTRS)

    Edelstein, Wendy N.; Andricos, Constantine; Wang, Feiyu; Rutled, David B.

    2005-01-01

    Future interferometric synthetic aperture radar (InSAR) systems require electronically scanned phased-array antennas, where the transmit/receive (T/R) module is a key component. The T/R module efficiency is a critical figure of merit and has direct implications on the power dissipation and power generation requirements of the system. Significant improvements in the efficiency of the T/R module will make SAR missions more feasible and affordable. The results of two high-efficiency T/R modules are presented, each based on different power amplifier technologies. One module uses a 30W GaAs Class-AlB power amplifier and the second module uses a 70W LD-MOS Class-ElF power amplifier, where both modules use a common low power section. Each module operates over an 80MHz bandwidth at L-band (1.2GHz) with an overall module efficiency greater than 58%. We will present the results of these two T/R modules that have been designed, built and tested.

  8. Automated Formal Testing of C API Using T2C Framework

    NASA Astrophysics Data System (ADS)

    Khoroshilov, Alexey V.; Rubanov, Vladimir V.; Shatokhin, Eugene A.

    A problem of automated test development for checking basic functionality of program interfaces (API) is discussed. Different technologies and corresponding tools are surveyed. And T2C technology developed in ISPRAS is presented. The technology and associated tools facilitate development of "medium quality" (and "medium cost") tests. An important feature of T2C technology is that it enforces that each check in a developed test is explicitly linked to the corresponding place in the standard. T2C tools provide convenient means to create such linkage. The results of using T2C are considered by example of a project for testing interfaces of Linux system libraries defined by the LSB standard.

  9. T1alpha/podoplanin shows raft-associated distribution in mouse lung alveolar epithelial E10 cells.

    PubMed

    Barth, Kathrin; Bläsche, Robert; Kasper, Michael

    2010-01-01

    T1alpha/(podoplanin) is abundantly expressed in the alveolar epithelial type I cells (ATI) of rodent and human lungs. Caveolin-1 is a classical primary structural protein of plasmalemal invaginations, so-called caveolae, which represent specialized lipid rafts, and which are particularly abundant in ATI cells. The biological functions of T1alpha in the alveolar epithelium are unknown. Here we report on the characteristics of raft domains in the microplicae/microvillar protrusions of ATI cells, which contain T1alpha. Detergent resistant membranes (DRMs) from cell lysates of the mouse epithelial ATI-like cell line E10 were prepared using different detergents followed by flotation in a sucrose gradient and tested by Western and dot blots with raft markers (caveolin-1, GM1) and nonraft markers (transferrin receptor, PDI and beta-Cop). Immunocytochemistry was employed for the localization of T1alpha in E10 cells and in situ in rat lungs. Our biochemical results showed that the solubility or insolubility of T1alpha and caveolin-1 differs in Triton X-100 and Lubrol WX, two distinct non-ionic detergents. Caveolin-1 was unsoluble in both detergents, whereas T1alpha was Triton X-100 soluble but Lubrol WX insoluble. Immunofluorescence double stainings revealed that both proteins were colocalized with GM1, while caveolin-1 and T1alpha were not colocalized in the plasma membrane. Cholesterol depletion modified the segregation of T1alpha in Lubrol WX DRMs. Cellular processes in ultrathin sections of cultured mouse E10 cells were immunogold positive. Immunoelectron microscopy (postembedding) of rat lung tissue revealed the preferential localization of T1alpha on apical microvillar protrusions of ATI cells. We conclude that T1alpha and caveolin-1 are located in distinct plasma membrane microdomains, which differ in their protein-lipid interactions. The raft-associated distribution of T1alpha may have an impact on a specific, not yet clarified function of this protein in the

  10. Testing Delays Resulting in Increased Identification Accuracy in Line-Ups and Show-Ups.

    ERIC Educational Resources Information Center

    Dekle, Dawn J.

    1997-01-01

    Investigated time delays (immediate, two-three days, one week) between viewing a staged theft and attempting an eyewitness identification. Compared lineups to one-person showups in a laboratory analogue involving 412 subjects. Results show that across all time delays, participants maintained a higher identification accuracy with the showup…

  11. Four-way-leaning test shows larger limits of stability than a circular-leaning test.

    PubMed

    Thomsen, Mikkel Højgaard; Støttrup, Nicolai; Larsen, Frederik Greve; Pedersen, Ann-Marie Sydow Krogh; Poulsen, Anne Grove; Hirata, Rogerio Pessoto

    2017-01-01

    Limits of stability (LOS) have extensive clinical and rehabilitational value yet no standard consensus on measuring LOS exists. LOS measured using a leaning or a circling protocol is commonly used in research and clinical settings, however differences in protocols and reliability problems exist. This study measured LOS using a four-way-leaning test and a circular-leaning test to test which showed larger LOS measurements. Furthermore, number of adaptation trials needed for consistent results was assessed. Limits of stability were measured using a force plate (Metitur Good Balance System ® ) sampling at 50Hz. Thirty healthy subjects completed 30 trials assessing LOS alternating between four-way-leaning test and circular-leaning test. A main effect of methods (ANOVA:F(1,28)=45.86, P<0.01) with the four-way-leaning test showing larger values than the circular-leaning test (NK, P<0.01). An interaction between method×directions was found (ANOVA:F(3, 84)=24.87, P<0.01). The four-way-leaning test showed larger LOS in anterior (NK, P<0.05), right (NK, P<0.01) and left direction (NK, P<0.01). Analysis of LOS for the four-way-leaning test showed a difference between trials (ANOVA:F(14,392)=7.81, P<0.01). Differences were found between trial 1 and 7 (NK, P<0.03), trial 6 and 8 (NK, P<0.02) and trial 7 and 15 (NK, P<0.02). Four-way-leaning test showed high correlation (ICC>0.87) between first and second trial for all directions. Four-way-leaning test yields larger LOS in anterior, right and left direction making it more reliable when measuring LOS. A learning effect was found up to the 8th trial, which suggests using 8 adaptation trials before reliable LOS is measured. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. EGFR T790M mutation testing within the osimertinib AURA Phase I study.

    PubMed

    Dearden, Simon; Brown, Helen; Jenkins, Suzanne; Thress, Kenneth S; Cantarini, Mireille; Cole, Rebecca; Ranson, Malcolm; Jänne, Pasi A

    2017-07-01

    Reliable epidermal growth factor receptor (EGFR) mutation testing techniques are required to identify eligible patients with EGFR mutation/T790M positive advanced non-small cell lung cancer (NSCLC), for treatment with osimertinib (AZD9291), an oral, potent, irreversible EGFR tyrosine kinase inhibitor (TKI) selective for EGFR-TKI-sensitizing and T790M resistance mutations over wild-type EGFR. There is no current consensus regarding the best method to detect EGFR T790M mutations. The aim of this study was to describe the concordance between local testing, which used a variety of methods, and central testing, using the cobas ® EGFR Mutation Test, for EGFR-sensitizing mutations and the T790M resistance mutation. Tumor samples were obtained from all patients screened for inclusion onto the osimertinib Phase I expansion component of the AURA Phase I/II study (NCT01802632). Samples underwent central laboratory testing for EGFR-sensitizing mutations and T790M resistance mutation using the cobas ® EGFR Mutation Test. Results were compared with local laboratory test results, based on other testing methodologies including Sanger sequencing, therascreen ® , PNAClamp™, and Sequenom MassARRAY ® . Central laboratory testing was successful in 99% of samples passing histopathology review and testing success rates were comparable across the three central laboratories. Concordance between central and local testing for common sensitizing mutations was high (>98%) and concordance for the T790M mutation was also high (>90%). Tumor heterogeneity, along with other technical factors may have influenced this result. Within the osimertinib AURA Phase I study, EGFR mutation testing across three centralized laboratories using the cobas ® EGFR Mutation Test was feasible and successful, with strong concordance between local and central laboratory results, including for T790M. The cobas ® EGFR Mutation Test has subsequently been approved as the companion diagnostic test for osimertinib in

  13. The PHA Test Reflects Acquired T-Cell Mediated Immunocompetence in Birds

    PubMed Central

    Tella, José L.; Lemus, Jesús A.; Carrete, Martina; Blanco, Guillermo

    2008-01-01

    Background cological immunology requires techniques to reliably measure immunocompetence in wild vertebrates. The PHA-skin test, involving subcutaneous injection of a mitogen (phytohemagglutinin, PHA) and measurement of subsequent swelling as a surrogate of T-cell mediated immunocompetence, has been the test of choice due to its practicality and ease of use in the field. However, mechanisms involved in local immunological and inflammatory processes provoked by PHA are poorly known, and its use and interpretation as an acquired immune response is currently debated. Methodology Here, we present experimental work using a variety of parrot species, to ascertain whether PHA exposure produces larger secondary than primary responses as expected if the test reflects acquired immunocompetence. Moreover, we simultaneously quantified T-lymphocyte subsets (CD4+, CD5+ and CD8+) and plasma proteins circulating in the bloodstream, potentially involved in the immunological and inflammatory processes, through flow cytometry and electrophoresis. Principal Findings Our results showed stronger responses after a second PHA injection, independent of species, time elapsed and changes in body mass of birds between first and second injections, thus supporting the adaptive nature of this immune response. Furthermore, the concomitant changes in the plasma concentrations of T-lymphocyte subsets and globulins indicate a causal link between the activation of the T-cell mediated immune system and local tissue swelling. Conclusions/Significance These findings justify the widespread use of the PHA-skin test as a reliable evaluator of acquired T-cell mediated immunocompetence in diverse biological disciplines. Further experimental research should be aimed at evaluating the relative role of innate immunocompetence in wild conditions, where the access to dietary proteins varies more than in captivity, and to ascertain how PHA responses relate to particular host-parasite interactions. PMID:18820730

  14. Tuberculin skin testing and T-SPOT.TB in internationally adopted children.

    PubMed

    Spicer, Kevin B; Turner, Joanne; Wang, Shu-Hua; Koranyi, Katalin; Powell, Dwight A

    2015-06-01

    Diagnosis of latent tuberculosis infection is a problem in children because of lack of a diagnostic standard and potential impact of previous Bacille Calmette-Guérin vaccination and exposure to environmental mycobacteria. Effectiveness and usefulness of interferon-gamma release assays in infants and younger children have yet to be clearly demonstrated. Prospective cohort study including 109 children (4 months to 16 years) seen in an international adoption clinic at Nationwide Children's Hospital, Columbus, OH. Children were adopted from 14 countries, mostly (72.5%) from China, Russia and Ethiopia. Correspondence between tuberculin skin test (TST) and the T-SPOT.TB assay was evaluated. Factors associated with positive results on the TST and T-SPOT.TB were determined, and the impact of age on test performance was specifically addressed. TST was positive in 23.4% (25 of 107). T-SPOT.TB was positive in 4.6% (5 of 109). Overall agreement between TST and T-SPOT.TB was 71%, with prevalence-adjusted, bias-adjusted Kappa of 0.68. History of Mycobacterium tuberculosis exposure was associated with positive results on TST (odds ratio: 25.4, 95% confidence interval: 4.8-261.6, exact logistic regression) and T-SPOT.TB (odds ratio: 78.9, 95% confidence interval: 9.7-∞). All 5 children with positive T-SPOT.TB had TST induration ≥15 mm. No patient less than 1 year of age (n = 17) had positive TST or T-SPOT.TB. Positive TST was not associated with Bacille Calmette-Guérin vaccination or scar. TST was positive in a significant percentage of international adoptees. T-SPOT.TB was rarely positive and discordant results reflected negative T-SPOT.TB with positive TST. In this population latent tuberculosis infection may be over-estimated by TST. Regardless, in our context at the time of the study, treatment decisions were based upon TST results, not results of the T-SPOT.TB assay. Age was consistently associated with findings on TST and T-SPOT.TB with no positive result on either

  15. Torsion Tests of 24S-T Aluminum-alloy Noncircular Bar and Tubing

    NASA Technical Reports Server (NTRS)

    Moore, R L; Paul, D A

    1943-01-01

    Tests of 24S-T aluminum alloy have been made to determine the yield and ultimate strengths in torsion of noncircular bar and tubing. An approximate basis for predicting these torsional strength characteristics has been indicated. The results show that the torsional stiffness and maximum shearing stresses within the elastic range may be computed quite closely by means of existing formulas based on mathematical analysis and the membrane analogy.

  16. Detecting differentially expressed genes in heterogeneous diseases using half Student's t-test.

    PubMed

    Hsu, Chun-Lun; Lee, Wen-Chung

    2010-12-01

    Microarray technology provides information about hundreds and thousands of gene-expression data in a single experiment. To search for disease-related genes, researchers test for those genes that are differentially expressed between the case subjects and the control subjects. The authors propose a new test, the 'half Student's t-test', specifically for detecting differentially expressed genes in heterogeneous diseases. Monte-Carlo simulation shows that the test maintains the nominal α level quite well for both normal and non-normal distributions. Power of the half Student's t is higher than that of the conventional 'pooled' Student's t when there is heterogeneity in the disease under study. The power gain by using the half Student's t can reach ∼10% when the standard deviation of the case group is 50% larger than that of the control group. Application to a colon cancer data reveals that when the false discovery rate (FDR) is controlled at 0.05, the half Student's t can detect 344 differentially expressed genes, whereas the pooled Student's t can detect only 65 genes. Or alternatively, if only 50 genes are to be selected, the FDR for the pooled Student's t has to be set at 0.0320 (false positive rate of ∼3%), but for the half Student's t, it can be at as low as 0.0001 (false positive rate of about one per ten thousands). The half Student's t-test is to be recommended for the detection of differentially expressed genes in heterogeneous diseases.

  17. Limonene hydroperoxide analogues show specific patch test reactions.

    PubMed

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. A goodness-of-fit test for capture-recapture model M(t) under closure

    USGS Publications Warehouse

    Stanley, T.R.; Burnham, K.P.

    1999-01-01

    A new, fully efficient goodness-of-fit test for the time-specific closed-population capture-recapture model M(t) is presented. This test is based on the residual distribution of the capture history data given the maximum likelihood parameter estimates under model M(t), is partitioned into informative components, and is based on chi-square statistics. Comparison of this test with Leslie's test (Leslie, 1958, Journal of Animal Ecology 27, 84- 86) for model M(t), using Monte Carlo simulations, shows the new test generally outperforms Leslie's test. The new test is frequently computable when Leslie's test is not, has Type I error rates that are closer to nominal error rates than Leslie's test, and is sensitive to behavioral variation and heterogeneity in capture probabilities. Leslie's test is not sensitive to behavioral variation in capture probabilities but, when computable, has greater power to detect heterogeneity than the new test.

  19. SECTIONS T AND S FROM NORTH DRIVE, SHOWING UPRIGHT HEADSTONES. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SECTIONS T AND S FROM NORTH DRIVE, SHOWING UPRIGHT HEADSTONES. VIEW TO SOUTH. - Rock Island National Cemetery, Rock Island Arsenal, 0.25 mile north of southern tip of Rock Island, Rock Island, Rock Island County, IL

  20. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  1. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  2. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  3. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  4. 49 CFR 236.110 - Results of tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Results of tests. 236.110 Section 236.110...: All Systems Inspections and Tests; All Systems § 236.110 Results of tests. (a) Results of tests made... records must show the name of the railroad, place and date, equipment tested, results of tests, repairs...

  5. Round Robin Fatigue Crack Growth Testing Results

    DTIC Science & Technology

    2006-11-01

    testing was accomplished, in accordance with ASTM E647, using two different capacity SATEC frames-a 20 kip test frame for the 7075-T6 panels and a 55 kip...Equipment and Setup a. SATEC b. 20 kip (7075-T6); 55 kip (2024-T351) c. Test control hardware/software i. Hardware: Teststar Ilm ii. Software: Station...5c. WROGRK M UN LEMBERTNME 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) S. PERFORMING ORGANIZATION REPORT NUMBER Center for A44rcraft

  6. Primary hypolactasia diagnosis: Comparison between the gaxilose test, shortened lactose tolerance test, and clinical parameters corresponding to the C/T-13910 polymorphism.

    PubMed

    Domínguez Jiménez, José Luis; Fernández Suárez, Antonio; Muñoz Colmenero, Aurora Úrsula; Fatela Cantillo, Daniel; López Pelayo, Iratxe

    2017-04-01

    There is no consensus on the most accurate method to diagnose primary hypolactasia. We aimed to compare the diagnostic accuracy of the new gaxilose test with 2 traditional tests (lactose tolerance test and clinical criteria) for the diagnosis of primary hypolactasia using the C/T-13910 polymorphism as a reference standard. Patients with a clinical suspicion of lactose intolerance were subjected to gaxilose tests, shortened lactose tolerance tests, and symptom questionnaires before and after overload with 50 g lactose and after a lactose-free diet. The diagnostic accuracy and degree of agreement and correlation were assessed using a genetic test (C/T-13910 polymorphism) as a reference standard and their respective 95% confidence intervals. Thirty consecutive patients (70% women) participated in the study. The genetic test confirmed the C/T-13910 polymorphism in 11 patients (36.8%). The presence of diarrhoea and the symptom score after lactose overload, along with the tolerance test, were the variables with the highest degree of agreement (κ > 0.60). Area under the ROC curve was >0.82 (p < 0.05), with sensitivity and specificity values of >0.80. However, the gaxilose test obtained lower values: κ, 0.47; area under curve, 0.75 (0.57-0.94); sensitivity, 0.82 (0.55-1); and specificity, 0.68 (0.45-0.92). The multivariate analysis showed an association between the post-overload symptom questionnaire and the results of the genetic test (odds ratio: 1.17; 1.04-1.31; p < 0.01). The presence of diarrhoea and the symptom score after overload with 50 g lactose showed a higher degree of agreement and diagnostic accuracy for primary hypolactasia than the gaxilose test when the genetic test is used as a reference standard. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  7. Testing Viable f(T) Models with Current Observations

    NASA Astrophysics Data System (ADS)

    Xu, Bing; Yu, Hongwei; Wu, Puxun

    2018-03-01

    We perform observational tests on the f(T) gravity with the BAO data (including the BOSS DR 12 galaxy sample, the DR12 Lyα-Forests measurement, the new eBOSS DR14 quasar sample, the 6dFGS, and the SDSS), the CMB distance priors from the Planck 2015, the SNIa data from the joint light-curve analysis, the latest H(z) data, and the local value of the Hubble constant. Six different f(T) models are investigated. Furthermore, the ΛCDM is also considered. All models are compared by using the Akaike information criteria (AIC) and the Bayesian information criteria (BIC). Our results show that the ΛCDM remains to be the most favored model by current observations. However, there are also the Hubble constant tension between the Planck measurements and the local Universe observations and the tension between the CMB data and the H(z) data in the ΛCDM. For f(T) models considered in this paper, half, which can reduce to the ΛCDM, have values of {{χ }2}\\min smaller than that of the ΛCDM and can relieve the tensions existing in the ΛCDM. However, they are punished slightly by the BIC due to one extra parameter. Two of six f(T) models, in which the crossing of the phantom divide line can be realized for the equation of state of the effective dark energy and this crossing is shown in this paper to be favored by current observations, are punished by the information criteria. In addition, we find that the logarithmic f(T) model is excluded by cosmological observations.

  8. 1. TEST STAND 1A ENVIRONS, SHOWING WEST SIDE OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEST STAND 1-A ENVIRONS, SHOWING WEST SIDE OF TEST STAND 1-A, RP1 COMBINED FUEL STORAGE TANK FARM BELOW WATER TANKS ON HILLSIDE TO LEFT, AND TEST STAND 1-B IN DISTANCE AT RIGHT. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  9. Risk factors for false-negative T-SPOT.TB assay results in patients with pulmonary and extra-pulmonary TB.

    PubMed

    Pan, Liping; Jia, Hongyan; Liu, Fei; Sun, Huishan; Gao, Mengqiu; Du, Fengjiao; Xing, Aiying; Du, Boping; Sun, Qi; Wei, Rongrong; Gu, Shuxiang; Zhang, Zongde

    2015-04-01

    To investigate the risk factors for false-negative T-SPOT.TB results in patients with pulmonary TB (PTB) and extra-pulmonary TB (EPTB). Patients with suspected TB who underwent valid T-SPOT.TB tests were prospectively enrolled at Beijing Chest Hospital between November 2012 and November 2013. Basic characters and clinical laboratory findings were compared between true-positive and false-negative T-SPOT.TB groups. Of 1928 suspected TB patients, 774 (530 PTB and 244 EPTB) microbiologically/histopathogenically-confirmed patients (636 culture-confirmed) were analyzed. Forty-six PTB patients (8.7%) and 32 EPTB patients (13.1%) had negative T-SPOT.TB results. Multivariate analysis showed that increased age [odds radio (OR) 2.26, 95% confidence interval (CI) 1.11-4.58], over-weight (BMI ≥ 25 kg/m(2), OR 2.43, 95% CI 1.05-5.63), and a longer period of illness before hospitalization (>6 months, OR 2.46, 95% CI 1.24-4.92) were independent risk factors for false-negative T-SPOT.TB results in PTB patients. In EPTB patients, increased age (OR 2.42, 95% CI 1.09-5.35) also showed an independent association with false-negative T-SPOT.TB results. Careful interpretation of negative T-SPOT.TB results is necessary in older patients with suspected PTB or EPTB, and in PTB patients who are over-weight or have had longer periods of illness before hospitalization. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  10. Differentiation of Trypanosoma brucei, T. rhodesiense, and T. gambiense by the indirect fluorescent antibody test

    PubMed Central

    Latif, B. M. A.; Adam, Katherine M. G.

    1973-01-01

    Epidemiological studies, if they are to lead to appropriate preventive procedures, require knowledge of the host distribution of the parasite. Progress in the epidemiology of African trypanosomiasis is restricted by the lack of a reliable and simple method of differentiating Trypanosoma brucei, T. rhodesiense, and T. gambiense. The recently introduced blood inoculation infectivity test promises to fulfil this need by distinguishing T. brucei from T. rhodesiense, but it would not be suitable for separating T. brucei from T. gambiense, since rats and mice are frequently refractory to infection by fresh isolates of T. gambiense. Previous studies had indicated that the indirect fluorescent antibody test might differentiate not only the subgenera of the salivarian trypanosome species but also members of the subgenus Trypanozoon. A method of performing the test is described that enables T. brucei, T. rhodesiense, and T. gambiense to be differentiated by the titre of the sera. The method might be used in conjunction with the blood inoculation infectivity test to distinguish between new isolates of the subgenus Trypanozoon in East Africa, and also to search for possible animal reservoirs of T. gambiense in West Africa. PMID:4587481

  11. SU-E-T-769: T-Test Based Prior Error Estimate and Stopping Criterion for Monte Carlo Dose Calculation in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, X; Gao, H; Schuemann, J

    2015-06-15

    Purpose: The Monte Carlo (MC) method is a gold standard for dose calculation in radiotherapy. However, it is not a priori clear how many particles need to be simulated to achieve a given dose accuracy. Prior error estimate and stopping criterion are not well established for MC. This work aims to fill this gap. Methods: Due to the statistical nature of MC, our approach is based on one-sample t-test. We design the prior error estimate method based on the t-test, and then use this t-test based error estimate for developing a simulation stopping criterion. The three major components are asmore » follows.First, the source particles are randomized in energy, space and angle, so that the dose deposition from a particle to the voxel is independent and identically distributed (i.i.d.).Second, a sample under consideration in the t-test is the mean value of dose deposition to the voxel by sufficiently large number of source particles. Then according to central limit theorem, the sample as the mean value of i.i.d. variables is normally distributed with the expectation equal to the true deposited dose.Third, the t-test is performed with the null hypothesis that the difference between sample expectation (the same as true deposited dose) and on-the-fly calculated mean sample dose from MC is larger than a given error threshold, in addition to which users have the freedom to specify confidence probability and region of interest in the t-test based stopping criterion. Results: The method is validated for proton dose calculation. The difference between the MC Result based on the t-test prior error estimate and the statistical Result by repeating numerous MC simulations is within 1%. Conclusion: The t-test based prior error estimate and stopping criterion are developed for MC and validated for proton dose calculation. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)« less

  12. Angioimmunoblastic T-cell lymphoma in Taiwan shows a frequent gain of ITK gene

    PubMed Central

    Liang, Peir-In; Chang, Sheng-Tsung; Lin, Ming-Yen; Hsieh, Yen-Chuan; Chu, Pei-Yi; Chen, Chih-Jung; Lin, Kai-Jen; Jung, Yun-Chih; Hwang, Wei-Shou; Huang, Wen-Tsung; Chang, Wei-Chin; Ye, Hongtao; Chuang, Shih-Sung

    2014-01-01

    Angioimmunoblastic T-cell lymphoma (AITL) is an aggressive peripheral T-cell lymphoma (PTCL) of follicular helper T-cell origin and is rare in Taiwan. There are overlapping features of AITL and peripheral T-cell lymphoma with a follicular growth pattern (PTCL-F). Around one fifth of PTCL-F exhibits t(5;9)(q33;q22)/ITK-SYK chromosomal translocation, which is essentially absent in AITL. We retrospectively investigated 35 cases of AITL from Taiwan with histopathology review, immunohistochemistry, in situ hybridization for Epstein-Barr virus (EBV) and fluorescence in situ hybridization (FISH) for t(5;9)(q33;q22)/ITK-SYK and correlated the results with overall survival. Twenty-six cases of not otherwise specified PTCL (PTCL-NOS) were also examined by FISH for comparison. Most AITL patients were male (69%) and elderly (median age at 67 years) with frequent bone marrow involvement (53%), high Ann Arbor stages (77%), and elevated serum lactate dehydrogenase (68%). Most cases (80%) showed a typical CD4+/CD8- phenotype and in 90% cases there were scattered EBV-positive B-cells (less than 10% cells). None of these cases showed t(5;9)(q33;q22)/ITK-SYK translocation by FISH. Gain of ITK and SYK gene was identified in 38% and 14% tumors, respectively, but both were not associated with overall survival. Performance status < 2 was associated with a better outcome but not the other clinicopathological factors. All PTCL-NOS cases were negative for ITK-SYK translocation with similar rates (38% and 12%, respectively) of gains at ITK and SYK loci as that of AITL. In this so far the largest series of AITL from Taiwan, we reported the clinicopathological features and FISH findings on ITK and SYK genes. We confirmed the absence of t(5;9)(q33;q22)/ITK-SYK translocation, which may serve as an additional differential diagnostic tool from PTCL-F when present. PTCL-NOS shared a similar pattern of ITK and SYK gains with AITL. More studies are warranted to elucidate the roles of SYK and ITK and

  13. Test wells T23, T29, and T30, White Sands Missile Range and Fort Bliss Military Reservation, Dona Ana County, New Mexico

    USGS Publications Warehouse

    Myers, R.G.; Pinckley, K.M.

    1984-01-01

    Three test wells, T23, T29, and T30, were drilled in south-central New Mexico as part of a joint military training program sponsored by the U.S. Army in November 1982. Test well T23 was drilled as an exploratory and monitoring well in the proposed Soledad well field at the Fort Bliss Military Reservation. Test wells T29 and T30 were drilled at White Sands Missile Range. Test well T29 was drilled as an observation well in the vicinity of the outfall channel from the sewage treatment plant. Test well T30 was drilled as an observation well for a landfill south of the well site. Information obtained from these wells includes lithologic logs for all wells and borehole-geophysical logs from the cased wells for test wells T29 and T30. (USGS)

  14. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    PubMed

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. [CLINICAL UTILITY OF T-SPOT.TB ASSAY WITH T-Cell Xtend REAGENT FOR ACTIVE TUBERCULOSIS DIAGNOSIS IN THE FIELD TEST AT OUR HOSPITAL].

    PubMed

    Nemoto, Kenji; Oh-ishi, Shuji; Taguchi, Masato; Hyodo, Kentaro; Kanazawa, Jun; Miura, Yukiko; Takaku, Takio; Usui, Shingo; Hayashihara, Kenji; Saito, Takefumi

    2016-04-01

    T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.

  16. Drug and alcohol testing results 2006 annual report.

    DOT National Transportation Integrated Search

    2008-08-01

    This is the 12th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2006, the requirements of the overall drug and alcohol t...

  17. Tuberculin skin test and ELISPOT/T. SPOT.TB in children and adolescents with juvenile idiopathic arthritis

    PubMed Central

    2014-01-01

    Background There are controversies regarding the accuracy of the tuberculin skin test (TST) and methods based on the production of interferon gamma by sensitized T cells for the diagnosis of latent tuberculosis infection (LTBI) in pediatrics and immunosuppressed patients. Our objectives are to study TST and ELISPOT/T. SPOT.TB in the diagnosis of LTBI in children and adolescents with JIA undergoing methotrexate, the correlation between both and the sensitivity and specificity of T. SPOT.TB. Methods This is an observational prospective longitudinal study in which children and adolescents with JIA undergoing methotrexate therapy were assessed for clinical and epidemiological data for LTBI, in addition to performing TST and T. SPOT.TB at baseline and after 3 and 12months. Results There were 24 patients. The prevalence of LTBI at inclusion was 20.8%, the incidence after initiation of immunosuppressions 26.3% and the prevalence at the end of the study 41.6%. Epidemiological history positive for TB showed a relative risk of 2.0 for the development of LTBI. Only 2 patients had positive T. SPOT.TB but only in one it was useful for detecting early LTBI. T. SPOT.TB presented a sensitivity of 10%, specificity of 92.8%, and low correlation with TST. No patient developed TB disease at a mean follow-up of 47months. Conclusions We found a high prevalence of ILTB that doubled with immunosuppression and that epidemiological history was an important relative risk. T. SPOT.TB showed low sensitivity and high specificity, and no superiority over TST. There was low agreement and little influence of immunosuppression on the results of both tests. PMID:24904240

  18. Migraine patients consistently show abnormal vestibular bedside tests.

    PubMed

    Maranhão, Eliana Teixeira; Maranhão-Filho, Péricles; Luiz, Ronir Raggio; Vincent, Maurice Borges

    2016-01-01

    Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs. To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR) responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls. Cross-sectional study including sixty individuals - thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls. Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity). Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.

  19. Axial Fatigue Tests at Zero Mean Stress of 24S-T and 75S-T Aluminum-alloy Strips with a Central Circular Hole

    NASA Technical Reports Server (NTRS)

    Brueggeman, W C; Mayer, M JR

    1948-01-01

    Axial fatigue tests at zero mean stress have been made on 0.032- and 0.064-inch 24S-T and 0.032-inch 75S-T sheet-metal specimens 1/4, 1/2, 1, and 2 inches wide without a hole and with central holes giving a range of hole diameter D to specimen width W from 0.01 to 0.95. No systematic difference was noted between the results for the 0.032-inch and the 0.064-inch specimens although the latter seemed the more consistent. In general the fatigue strength based on the minimum section dropped sharply as the ration D/W was increased from zero to about 0.25. The plain specimens showed quite a pronounced decrease in fatigue strength with increasing width. The holed specimens showed only slight and rather inconclusive evidence of this size effect. The fatigue stress-concentration factor was higher for 75S-T than for 24S-T alloy. Evidence was found that a very small hole would not cause any reduction in fatigue strength.

  20. Hybrid flower pollination algorithm strategies for t-way test suite generation.

    PubMed

    Nasser, Abdullah B; Zamli, Kamal Z; Alsewari, AbdulRahman A; Ahmed, Bestoun S

    2018-01-01

    The application of meta-heuristic algorithms for t-way testing has recently become prevalent. Consequently, many useful meta-heuristic algorithms have been developed on the basis of the implementation of t-way strategies (where t indicates the interaction strength). Mixed results have been reported in the literature to highlight the fact that no single strategy appears to be superior compared with other configurations. The hybridization of two or more algorithms can enhance the overall search capabilities, that is, by compensating the limitation of one algorithm with the strength of others. Thus, hybrid variants of the flower pollination algorithm (FPA) are proposed in the current work. Four hybrid variants of FPA are considered by combining FPA with other algorithmic components. The experimental results demonstrate that FPA hybrids overcome the problems of slow convergence in the original FPA and offers statistically superior performance compared with existing t-way strategies in terms of test suite size.

  1. Hybrid flower pollination algorithm strategies for t-way test suite generation

    PubMed Central

    Zamli, Kamal Z.; Alsewari, AbdulRahman A.

    2018-01-01

    The application of meta-heuristic algorithms for t-way testing has recently become prevalent. Consequently, many useful meta-heuristic algorithms have been developed on the basis of the implementation of t-way strategies (where t indicates the interaction strength). Mixed results have been reported in the literature to highlight the fact that no single strategy appears to be superior compared with other configurations. The hybridization of two or more algorithms can enhance the overall search capabilities, that is, by compensating the limitation of one algorithm with the strength of others. Thus, hybrid variants of the flower pollination algorithm (FPA) are proposed in the current work. Four hybrid variants of FPA are considered by combining FPA with other algorithmic components. The experimental results demonstrate that FPA hybrids overcome the problems of slow convergence in the original FPA and offers statistically superior performance compared with existing t-way strategies in terms of test suite size. PMID:29718918

  2. Altered Semmes-Weinstein monofilament test results are associated with oxidative stress markers in type 2 diabetic subjects.

    PubMed

    Martinez-Hervás, Sergio; Mendez, Mercedes Molina; Folgado, José; Tormos, Carmen; Ascaso, Pilar; Peiró, Marta; Real, Jose T; Ascaso, Juan F

    2017-09-06

    Different lines of evidence suggest that oxidative stress (OS) is implicated in the pathogenesis of diabetic neuropathy. The Semmes-Weinstein monofilament (SWM) test is an efficient tool for evaluating diabetic polyneuropathy and diabetic foot. In this study, we analyzed the association between OS markers and altered SWM test results in type 2 diabetes (T2DM) patients. Seventy T2DM patients were studied and 34 showed altered SWM results. The clinical and biochemical parameters were determined using standardized methods. Levels of oxidized glutathione (GSSG) and malondialdehyde (MDA) were measured in circulating mononuclear cells using high-performance liquid chromatography. We found that T2DM patients with altered SWM test results had significantly higher GSSG (3.53 ± 0.31 vs. 3.31 ± 0.35 mmol/ml, p < 0.05) and MDA (1.88 ± 0.16 vs. 1.75 ± 0.19 nmol/ml, p < 0.01) values compared to diabetic patients with normal SWM test outcomes. Moreover, altered SWM test results were independently related to age, glycosylated hemoglobin, and GSSG levels, but there was no association between OS markers and altered neuropathy sensitivity score (NSS) values. Alteration of the glutathione system and MDA values in T2DM patients are associated with loss of proprioceptive (pressure) sensitivity, but not with symptomatic polyneuropathy (as evaluated by NSS). This finding may be important for understanding how OS affects distal symmetric polyneuropathy in diabetic patients.

  3. 11. Detail of Bed Plate Showing Name of Manufacturer (T.W. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Detail of Bed Plate Showing Name of Manufacturer (T.W. Phillips Manufacturing Co.), Looking Southwest - Heckert Oil Pumping Jack, 0.6 mile North of Connoquenessing Creek, 0.15 mile East of Powder Mill Creek, Renfrew, Butler County, PA

  4. [Effects of incubation temperature on the results of passive hemagglutination test].

    PubMed

    Gorchakov, Iu L

    1993-01-01

    Passive hemagglutination test was carried out at several incubation temperatures: 4, 21, 37, and 56 degrees C. Blood sera of donors, salmonellosis enteritidis patients, and specific nonadsorbed sera were used in the study. The least fluctuations of the results were seen in tests with the sera with the least manifest immune properties. The optimal incubation temperatures were found 4 and 21 degrees C, and in 1/3 of cases cold incubation was found preferable. The relationship between antibody titers and incubation temperature may be described by the formula: T4 > or = T21 > or = T37 > or = T56, with Tn representing the reverse value of antibody titer in certain incubation temperature.

  5. A close examination of double filtering with fold change and t test in microarray analysis

    PubMed Central

    2009-01-01

    Background Many researchers use the double filtering procedure with fold change and t test to identify differentially expressed genes, in the hope that the double filtering will provide extra confidence in the results. Due to its simplicity, the double filtering procedure has been popular with applied researchers despite the development of more sophisticated methods. Results This paper, for the first time to our knowledge, provides theoretical insight on the drawback of the double filtering procedure. We show that fold change assumes all genes to have a common variance while t statistic assumes gene-specific variances. The two statistics are based on contradicting assumptions. Under the assumption that gene variances arise from a mixture of a common variance and gene-specific variances, we develop the theoretically most powerful likelihood ratio test statistic. We further demonstrate that the posterior inference based on a Bayesian mixture model and the widely used significance analysis of microarrays (SAM) statistic are better approximations to the likelihood ratio test than the double filtering procedure. Conclusion We demonstrate through hypothesis testing theory, simulation studies and real data examples, that well constructed shrinkage testing methods, which can be united under the mixture gene variance assumption, can considerably outperform the double filtering procedure. PMID:19995439

  6. GOES Type III Loop Heat Pipe Life Test Results

    NASA Technical Reports Server (NTRS)

    Ottenstein, Laura

    2011-01-01

    The GOES Type III Loop Heat Pipe (LHP) was built as a life test unit for the loop heat pipes on the GOES N-Q series satellites. This propylene LHP was built by Dynatherm Corporation in 2000 and tested continuously for approximately 14 months. It was then put into storage for 3 years. Following the storage period, the LHP was tested at Swales Aerospace to verify that the loop performance hadn t changed. Most test results were consistent with earlier results. At the conclusion of testing at Swales, the LHP was transferred to NASA/GSFC for continued periodic testing. The LHP has been set up for testing in the Thermal Lab at GSFC since 2006. A group of tests consisting of start-ups, power cycles, and a heat transport limit test have been performed every six to nine months since March 2006. Tests results have shown no change in the loop performance over the five years of testing. This presentation will discuss the test hardware, test set-up, and tests performed. Test results to be presented include sample plots from individual tests, along with conductance measurements for all tests performed.

  7. 12. TOOL ROOM SHOWING LANDIS MACHINE CO. BOL/T THREADER (L), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. TOOL ROOM SHOWING LANDIS MACHINE CO. BOL/T THREADER (L), OSTER MANUFACTURING CO. PIPE MASTER (R), AND OLDMAN KINK, A SHOP-MADE WELDING STRENGTH TESTER (L, BACKGROUND). VIEW NORTHEAST - Oldman Boiler Works, Office/Machine Shop, 32 Illinois Street, Buffalo, Erie County, NY

  8. Lithium cell test results

    NASA Technical Reports Server (NTRS)

    Bragg, B. J.

    1977-01-01

    Three lithium SO2 cells, two lithium CF cells, and a vinyl chloride cell, all with crimped seals, and all strictly experimental, were independently discharged on resistors. Three temperatures were used and several different storage temperatures. Discharge rate generally on the nominal discharges were 0.1 amp, 0.5 amp, and 1 amp. Tests results show that the crimp seals are inadequate, especially for the SO2 cells. Normal discharges present no hazards. All cells discharge to zero. The problem of lithium cell explosions, such as occurred during off-limits testing, is discussed.

  9. Laboratory test results for an airborne ASTER simulator

    NASA Astrophysics Data System (ADS)

    Ezaka, Teruya; Kannari, Yoshiaki; Mills, Franklin P.; Watanabe, Hiroshi; Sano, Masaharu; Chang, Sheng-Huei

    1993-08-01

    An airborne ASTER simulator (AAS) is being developed by the Geophysical Environmental Research Corporation (GER) to study land surface temperature and emittance in the thermal infrared. Laboratory tests in October 1992 at NASA's Stennis Space Center (SSC) measured the AAS's spectral, approximate NEdT, and approximate spatial response characteristics. The spectral FWHM for most channels is smaller than 0.3 micrometers ; the NEdT for most TIR channels is better than 0.4 K; and the nominal IFOV is 5 mrad. Flight data was collected over Cuprite and Goldfield, Nevada and near Valencia, California in November 1992. The silicified and opalized zones at Cuprite could be discriminated using decorrelation-stretch images. AAS decorrelation-stretch images agree, qualitatively, with data from NASA's thermal infrared mapping spectrometer (TIMS). These results indicate the AAS may be a good tool for remote sensing studies of geological materials. Lower noise detector arrays and linear variable (optical) filters for the TIR channels will be tested in flights over Cuprite, Nevada later this year. These and other improvements may reduce the NEdT and improve the signal-to-noise ratio.

  10. EGFR T790M mutation testing of non-small cell lung cancer tissue and blood samples artificially spiked with circulating cell-free tumor DNA: results of a round robin trial.

    PubMed

    Fassunke, Jana; Ihle, Michaela Angelika; Lenze, Dido; Lehmann, Annika; Hummel, Michael; Vollbrecht, Claudia; Penzel, Roland; Volckmar, Anna-Lena; Stenzinger, Albrecht; Endris, Volker; Jung, Andreas; Lehmann, Ulrich; Zeugner, Silke; Baretton, Gustavo; Kreipe, Hans; Schirmacher, Peter; Kirchner, Thomas; Dietel, Manfred; Büttner, Reinhard; Merkelbach-Bruse, Sabine

    2017-10-01

    The European Commision (EC) recently approved osimertinib for the treatment of adult patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC) harboring EGFR T790M mutations. Besides tissue-based testing, blood samples containing cell-free circulating tumor DNA (ctDNA) can be used to interrogate T790M status. Herein, we describe the conditions and results of a round robin trial (RRT) for T790M mutation testing in NSCLC tissue specimens and peripheral blood samples spiked with cell line DNA mimicking tumor-derived ctDNA. The underlying objectives of this two-staged external quality assessment (EQA) approach were (a) to evaluate the accuracy of T790M mutations testing across multiple centers and (b) to investigate if a liquid biopsy-based testing for T790M mutations in spiked blood samples is feasible in routine diagnostic. Based on a successfully completed internal phase I RRT, an open RRT for EGFR T790M mutation testing in tumor tissue and blood samples was initiated. In total, 48 pathology centers participated in the EQA. Of these, 47 (97.9%) centers submitted their analyses within the pre-defined time frame and 44 (tissue), respectively, 40 (plasma) successfully passed the test. The overall success rates in the RRT phase II were 91.7% (tissue) and 83.3% (blood), respectively. Thirty-eight out of 48 participants (79.2%) successfully passed both parts of the RRT. The RRT for blood-based EGFR testing initiated in Germany is, to the best of our knowledge, the first of his kind in Europe. In summary, our results demonstrate that blood-based genotyping for EGFR resistance mutations can be successfully integrated in routine molecular diagnostics complementing the array of molecular methods already available at pathology centers in Germany.

  11. ITER CS Model Coil and CS Insert Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martovetsky, N; Michael, P; Minervina, J

    2000-09-07

    The Inner and Outer modules of the Central Solenoid Model Coil (CSMC) were built by US and Japanese home teams in collaboration with European and Russian teams to demonstrate the feasibility of a superconducting Central Solenoid for ITER and other large tokamak reactors. The CSMC mass is about 120 t, OD is about 3.6 m and the stored energy is 640 MJ at 46 kA and peak field of 13 T. Testing of the CSMC and the CS Insert took place at Japan Atomic Energy Research Institute (JAERI) from mid March until mid August 2000. This paper presents the mainmore » results of the tests performed.« less

  12. The Use of Time Series Analysis and t Tests with Serially Correlated Data Tests.

    ERIC Educational Resources Information Center

    Nicolich, Mark J.; Weinstein, Carol S.

    1981-01-01

    Results of three methods of analysis applied to simulated autocorrelated data sets with an intervention point (varying in autocorrelation degree, variance of error term, and magnitude of intervention effect) are compared and presented. The three methods are: t tests; maximum likelihood Box-Jenkins (ARIMA); and Bayesian Box Jenkins. (Author/AEF)

  13. Could Acoustic Emission Testing Show a Pipe Failure in Advance?

    NASA Astrophysics Data System (ADS)

    Soares, S. D.; Teixeira, J. C. G.

    2004-02-01

    During the last 20 years PETROBRAS has been attempting to use Acoustic Emission (AE) as an inspection tool. In this period the AE concept has changed from a revolutionary method to a way of finding areas to make a complete inspection. PETROBRAS has a lot of pressure vessels inspected by AE and with other NDTs techniques to establish their relationship. In other hand, PETROBRAS R&D Center has conducted destructive hydrostatic tests in pipelines samples with artificial defects made by milling. Those tests were monitored by acoustic emission and manual ultrasonic until the complete failure of pipe sample. This article shows the results obtained and a brief proposal of analysis criteria for this environment of test.

  14. Monte Carlo Simulations Comparing Fisher Exact Test and Unequal Variances t Test for Analysis of Differences Between Groups in Brief Hospital Lengths of Stay.

    PubMed

    Dexter, Franklin; Bayman, Emine O; Dexter, Elisabeth U

    2017-12-01

    We examined type I and II error rates for analysis of (1) mean hospital length of stay (LOS) versus (2) percentage of hospital LOS that are overnight. These 2 end points are suitable for when LOS is treated as a secondary economic end point. We repeatedly resampled LOS for 5052 discharges of thoracoscopic wedge resections and lung lobectomy at 26 hospitals. Unequal variances t test (Welch method) and Fisher exact test both were conservative (ie, type I error rate less than nominal level). The Wilcoxon rank sum test was included as a comparator; the type I error rates did not differ from the nominal level of 0.05 or 0.01. Fisher exact test was more powerful than the unequal variances t test at detecting differences among hospitals; estimated odds ratio for obtaining P < .05 with Fisher exact test versus unequal variances t test = 1.94, with 95% confidence interval, 1.31-3.01. Fisher exact test and Wilcoxon-Mann-Whitney had comparable statistical power in terms of differentiating LOS between hospitals. For studies with LOS to be used as a secondary end point of economic interest, there is currently considerable interest in the planned analysis being for the percentage of patients suitable for ambulatory surgery (ie, hospital LOS equals 0 or 1 midnight). Our results show that there need not be a loss of statistical power when groups are compared using this binary end point, as compared with either Welch method or Wilcoxon rank sum test.

  15. Patient-Customized Drug Combination Prediction and Testing for T-cell Prolymphocytic Leukemia Patients.

    PubMed

    He, Liye; Tang, Jing; Andersson, Emma I; Timonen, Sanna; Koschmieder, Steffen; Wennerberg, Krister; Mustjoki, Satu; Aittokallio, Tero

    2018-05-01

    The molecular pathways that drive cancer progression and treatment resistance are highly redundant and variable between individual patients with the same cancer type. To tackle this complex rewiring of pathway cross-talk, personalized combination treatments targeting multiple cancer growth and survival pathways are required. Here we implemented a computational-experimental drug combination prediction and testing (DCPT) platform for efficient in silico prioritization and ex vivo testing in patient-derived samples to identify customized synergistic combinations for individual cancer patients. DCPT used drug-target interaction networks to traverse the massive combinatorial search spaces among 218 compounds (a total of 23,653 pairwise combinations) and identified cancer-selective synergies by using differential single-compound sensitivity profiles between patient cells and healthy controls, hence reducing the likelihood of toxic combination effects. A polypharmacology-based machine learning modeling and network visualization made use of baseline genomic and molecular profiles to guide patient-specific combination testing and clinical translation phases. Using T-cell prolymphocytic leukemia (T-PLL) as a first case study, we show how the DCPT platform successfully predicted distinct synergistic combinations for each of the three T-PLL patients, each presenting with different resistance patterns and synergy mechanisms. In total, 10 of 24 (42%) of selective combination predictions were experimentally confirmed to show synergy in patient-derived samples ex vivo The identified selective synergies among approved drugs, including tacrolimus and temsirolimus combined with BCL-2 inhibitor venetoclax, may offer novel drug repurposing opportunities for treating T-PLL. Significance: An integrated use of functional drug screening combined with genomic and molecular profiling enables patient-customized prediction and testing of drug combination synergies for T-PLL patients. Cancer

  16. Test wells T21, T22, and T25, White Sands Missile Range, Dona Ana County, New Mexico

    USGS Publications Warehouse

    Myers, R.G.

    1983-01-01

    Three test wells, T21, T22, and T25, were drilled at White Sands Missile Range in south-central New Mexico as part of a joint military program sponsored by the U.S. Army in September 1982. T21 and T22 were drilled as observation wells for two old landfills. T25 was drilled as an exploratory hole to obtain lithologic and borehole-geophysical data in the vicinity of the proposed replacement well for Supply Well 15. Information obtained from these wells includes borehole-geophysical and driller's logs.

  17. Determining Differences in Efficacy of Two Disinfectants Using t-Tests.

    ERIC Educational Resources Information Center

    Brehm, Michael A.; And Others

    1996-01-01

    Presents an experiment to compare the effectiveness of 95% ethanol to 20% bleach as disinfectants using t-tests for the statistical analysis of the data. Reports that bleach is a better disinfectant. Discusses the statistical and practical significance of the results. (JRH)

  18. Elevated high-sensitive troponin T in negative stress test individuals.

    PubMed

    Brzezinski, Rafael Y; Fisher, Eyal; Ehrenwald, Michal; Shefer, Gabi; Stern, Naftali; Shapira, Itzhak; Zeltser, David; Berliner, Shlomo; Shenhar-Tsarfaty, Shani; Milwidsky, Assi; Rogowski, Ori

    2018-06-01

    The exercise ECG stress test (EST) is still the first step of work-up in intermediate risk patients in many clinical scenarios. High-sensitive cardiac troponin T (hs-cTnT) elevation is related to future cardiovascular events in the general population and in patients with ischaemic heart disease. The relation between these 2 tests is not well described. A total of 2780 participants from the Tel-Aviv Medical Center Inflammation Survey cohort (mean age 49 years, 79% men) were analysed. Multiple physiologic and metabolic parameters including hs-cTnT were collected. All participants completed an EST manually reviewed by a cardiologist. A positive EST was documented in 224 subjects (8%). The majority (91%) of participants with hs-cTnT levels of 5-14 ng/L had a negative EST as well as 89.3% of subjects with levels >14 ng/L. The proportion of subjects with a positive EST and detectable hs-cTnT levels (>5 ng/L) was not significantly greater compared to those with a negative EST (53.1% vs 46.2%, respectively, P = .09). Among subjects referred for EST as part of an annual health survey, we found no significant association between EST results to hs-cTnT detection. © 2018 Stichting European Society for Clinical Investigation Journal Foundation.

  19. Functional Fitness Testing Results Following Long-Duration ISS Missions.

    PubMed

    Laughlin, Mitzi S; Guilliams, Mark E; Nieschwitz, Bruce A; Hoellen, David

    2015-12-01

    Long-duration spaceflight missions lead to the loss of muscle strength and endurance. Significant reduction in muscle function can be hazardous when returning from spaceflight. To document these losses, NASA developed medical requirements that include measures of functional strength and endurance. Results from this Functional Fitness Test (FFT) battery are also used to evaluate the effectiveness of in-flight exercise countermeasures. The purpose of this paper is to document results from the FFT and correlate this information with performance of in-flight exercise on board the International Space Station. The FFT evaluates muscular strength and endurance, flexibility, and agility and includes the following eight measures: sit and reach, cone agility, push-ups, pull-ups, sliding crunches, bench press, leg press, and hand grip dynamometry. Pre- to postflight functional fitness measurements were analyzed using dependent t-tests and correlation analyses were used to evaluate the relationship between functional fitness measurements and in-flight exercise workouts. Significant differences were noted post space flight with the sit and reach, cone agility, leg press, and hand grip measurements while other test scores were not significantly altered. The relationships between functional fitness and in-flight exercise measurements showed minimal to moderate correlations for most in-flight exercise training variables. The change in FFT results can be partially explained by in-flight exercise performance. Although there are losses documented in the FFT results, it is important to realize that the crewmembers are successfully performing activities of daily living and are considered functional for normal activities upon return to Earth.

  20. A closer look at the effect of preliminary goodness-of-fit testing for normality for the one-sample t-test.

    PubMed

    Rochon, Justine; Kieser, Meinhard

    2011-11-01

    Student's one-sample t-test is a commonly used method when inference about the population mean is made. As advocated in textbooks and articles, the assumption of normality is often checked by a preliminary goodness-of-fit (GOF) test. In a paper recently published by Schucany and Ng it was shown that, for the uniform distribution, screening of samples by a pretest for normality leads to a more conservative conditional Type I error rate than application of the one-sample t-test without preliminary GOF test. In contrast, for the exponential distribution, the conditional level is even more elevated than the Type I error rate of the t-test without pretest. We examine the reasons behind these characteristics. In a simulation study, samples drawn from the exponential, lognormal, uniform, Student's t-distribution with 2 degrees of freedom (t(2) ) and the standard normal distribution that had passed normality screening, as well as the ingredients of the test statistics calculated from these samples, are investigated. For non-normal distributions, we found that preliminary testing for normality may change the distribution of means and standard deviations of the selected samples as well as the correlation between them (if the underlying distribution is non-symmetric), thus leading to altered distributions of the resulting test statistics. It is shown that for skewed distributions the excess in Type I error rate may be even more pronounced when testing one-sided hypotheses. ©2010 The British Psychological Society.

  1. Test wells T27 and T28, White Sands Missile Range, Dona Ana County, New Mexico

    USGS Publications Warehouse

    Myers, R.G.; Pinckley, K.M.

    1985-01-01

    Two test wells, T27 and T28, were drilled at White Sands Missile Range in south-central New Mexico as part of a joint military training program sponsored by the U.S. Army in February and March 1983. Test wells T27 and T28 were drilled as observation wells in the vicinity of the Liquid Propellant Storage Area. Information obtained from these wells includes lithologic logs, driller 's logs, and borehole-geophysical logs from the cased wells. (USGS)

  2. Ground vibration test results of a JetStar airplane using impulsive sine excitation

    NASA Technical Reports Server (NTRS)

    Kehoe, Michael W.; Voracek, David F.

    1989-01-01

    Structural excitation is important for both ground vibration and flight flutter testing. The structural responses caused by this excitation are analyzed to determine frequency, damping, and mode shape information. Many excitation waveforms have been used throughout the years. The use of impulsive sine (sin omega t)/omega t as an excitation waveform for ground vibration testing and the advantages of using this waveform for flight flutter testing are discussed. The ground vibration test results of a modified JetStar airplane using impulsive sine as an excitation waveform are compared with the test results of the same airplane using multiple-input random excitation. The results indicated that the structure was sufficiently excited using the impulsive sine waveform. Comparisons of input force spectrums, mode shape plots, and frequency and damping values for the two methods of excitation are presented.

  3. 1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE TESTING AREA, AND PUMP TESTING TOWER. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  4. Test Results for Entry Guidance Methods for Space Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2004-01-01

    There are a number of approaches to advanced guidance and control that have the potential for achieving the goals of significantly increasing reusable launch vehicle (or any space vehicle that enters an atmosphere) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future vehicle concepts.

  5. Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

    NASA Technical Reports Server (NTRS)

    Russell, Carl R.

    2014-01-01

    Prior to the full-scale wind tunnel test of the UH-60A Airloads rotor, a shake test was completed on the Large Rotor Test Apparatus. The goal of the shake test was to characterize the oscillatory response of the test rig and provide a dynamic calibration of the balance to accurately measure vibratory hub loads. This paper provides a summary of the shake test results, including balance, shaft bending gauge, and accelerometer measurements. Sensitivity to hub mass and angle of attack were investigated during the shake test. Hub mass was found to have an important impact on the vibratory forces and moments measured at the balance, especially near the UH-60A 4/rev frequency. Comparisons were made between the accelerometer data and an existing finite-element model, showing agreement on mode shapes, but not on natural frequencies. Finally, the results of a simple dynamic calibration are presented, showing the effects of changes in hub mass. The results show that the shake test data can be used to correct in-plane loads measurements up to 10 Hz and normal loads up to 30 Hz.

  6. Some metallographic results for brush bristles and brush segments of a shroud ring brush seal tested in a T-700 engine

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Griffin, Thomas A.; Bobula, George A.; Bill, Robert C.; Hull, David R.; Csavina, Kristine R.

    1994-01-01

    Post-test investigation of a T-700 engine brush seal found regions void of bristles ('yanked out'), regions of bent-over bristles near the inlet, some 'snapped' bristles near the fence, and a more uniform smeared bristle interface between the first and last axial rows of bristles. Several bristles and four brush segments were cut from the brush seal, wax mounted, polished, and analyzed. Metallographic analysis of the bristle near the rub tip showed tungsten-rich phases uniformly distributed throughout the bristle, no apparent change within 1 mu m of the interface, and possibly a small amount of titanium, which would represent a transfer from the rotor. Analysis of the bristle wear face showed nonuniform tungsten, which is indicative of material resolidification. The cut end contained oxides and internal fractures; the worn end was covered with oxide scale. Material losses due to wear and elastoplastic deformation within the shear zone and third-body lubrication effects in the contact zone are discussed.

  7. Different Types of Luciferase Reporters Show Distinct Susceptibility to T3-Evoked Downregulation.

    PubMed

    Kollár, Anna; Kvárta-Papp, Zsuzsanna; Egri, Péter; Gereben, Balázs

    2016-01-01

    The firefly luciferase reporter protein is a crucial tool for studies targeting a broad range of biological questions. Importantly, luciferase assays are also widely used to explore mechanisms underlying thyroid hormone dependent regulation of gene expression. However, it was demonstrated that the firefly luciferase reporter is subject to triiodothyronine (T3)-evoked, promoter independent downregulation that is mediated by the thyroid hormone receptor. Since this effect can interfere with readout accuracy, the study aimed to find luciferase reporters that are not susceptible to this phenomenon. Luciferase reporter constructs were generated under the control of a minimal thymidine kinase (TK) promoter and transiently transfected into JEG-3 cells to test their activity upon T3 treatment. Activity of the TK-(dCpG)Luc encoding a synthetic (dCpG)Luciferase and TK-NanoLuc expressing the NanoLuc reporter was not significantly changed by T3 treatment while the firefly luciferase control was suppressed by ∼2.6-fold. T3 also downregulated the activity of Renilla luciferase by ∼30%. Novel types of luciferase reporters, especially the synthetic (dCpG)Luciferase, can be more accurate to study T3-regulated gene expression than the classical firefly luciferase reporter. Renilla luciferase, a popular transfection control of dual luciferase assays, should be used with caution in conditions with T3 treatment.

  8. Our Results-Driven, Testing Culture: How It Adversely Affects Students' Personal Experience

    ERIC Educational Resources Information Center

    Lesch, Lyn

    2007-01-01

    Author Lyn Lesch advocates that learning cannot be measured by empirical results like testing and grading. As the founder of Chicago's The Children's School, Lesch didn't give grades or submit students to standardized testing. Such conditions may seem blasphemous to most educators, but the results spoke for themselves. Without the high-stakes…

  9. The I Don't Know Option in the Vocabulary Size Test

    ERIC Educational Resources Information Center

    Zhang, Xian

    2013-01-01

    The current study evaluates guessing behaviors in a vocabulary size test (VST) and examines whether including an "I don't know" in a VST may have an impact on the results of the test. One-hundred-fifty first-year students at a university in China took part in the study. They were randomly assigned to three groups. Each group took a…

  10. Determining Mycobacterium tuberculosis Infection among BCG-Immunised Ugandan Children by T-SPOT.TB and Tuberculin Skin Testing

    PubMed Central

    Nkurunungi, Gyaviira; Lutangira, Jimreeves E.; Lule, Swaib A.; Akurut, Hellen; Kizindo, Robert; Fitchett, Joseph R.; Kizito, Dennison; Sebina, Ismail; Muhangi, Lawrence; Webb, Emily L.; Cose, Stephen; Elliott, Alison M.

    2012-01-01

    Background Children with latent tuberculosis infection (LTBI) represent a huge reservoir for future disease. We wished to determine Mycobacterium tuberculosis (M.tb) infection prevalence among BCG-immunised five-year-old children in Entebbe, Uganda, but there are limited data on the performance of immunoassays for diagnosis of tuberculosis infection in children in endemic settings. We therefore evaluated agreement between a commercial interferon gamma release assay (T-SPOT.TB) and the tuberculin skin test (TST; 2 units RT-23 tuberculin; positive defined as diameter ≥10 mm), along with the reproducibility of T-SPOT.TB on short-term follow-up, in this population. Methodology/Principal Findings We recruited 907 children of which 56 were household contacts of TB patients. They were tested with T-SPOT.TB at age five years and then re-examined with T-SPOT.TB (n = 405) and TST (n = 319) approximately three weeks later. The principal outcome measures were T-SPOT.TB and TST positivity. At five years, 88 (9.7%) children tested positive by T-SPOT.TB. More than half of those that were T-SPOT.TB positive at five years were negative at follow-up, whereas 96% of baseline negatives were consistently negative. We observed somewhat better agreement between initial and follow-up T-SPOT.TB results among household TB contacts (κ = 0.77) than among non-contacts (κ = 0.39). Agreement between T-SPOT.TB and TST was weak (κ = 0.28 and κ = 0.40 for T-SPOT.TB at 5 years and follow-up, respectively). Of 28 children who were positive on both T-SPOT.TB tests, 14 (50%) had a negative TST. Analysis of spot counts showed high levels of instability in responses between baseline and follow-up, indicating variability in circulating numbers of T cells specific for certain M.tb antigens. Conclusions/Significance We found that T-SPOT.TB positives are unstable over a three-week follow-up interval, and that TST compares poorly with T-SPOT.TB, making the categorisation of

  11. Viremic HIV Infected Individuals with High CD4 T Cells and Functional Envelope Proteins Show Anti-gp41 Antibodies with Unique Specificity and Function

    PubMed Central

    Curriu, Marta; Fausther-Bovendo, Hughes; Pernas, María; Massanella, Marta; Carrillo, Jorge; Cabrera, Cecilia; López-Galíndez, Cecilio; Clotet, Bonaventura; Debré, Patrice; Vieillard, Vincent; Blanco, Julià

    2012-01-01

    Background CD4 T-cell decay is variable among HIV-infected individuals. In exceptional cases, CD4 T-cell counts remain stable despite high plasma viremia. HIV envelope glycoprotein (Env) properties, namely tropism, fusion or the ability to induce the NK ligand NKp44L, or host factors that modulate Env cytopathic mechanisms may be modified in such situation. Methods We identified untreated HIV-infected individuals showing non-cytopathic replication (VL>10,000 copies/mL and CD4 T-cell decay<50 cells/µL/year, Viremic Non Progressors, VNP) or rapid progression (CD4 T-cells<350 cells/µL within three years post-infection, RP). We isolated full-length Env clones and analyzed their functions (tropism, fusion activity and capacity to induce NKp44L expression on CD4 cells). Anti-Env humoral responses were also analyzed. Results Env clones isolated from VNP or RP individuals showed no major phenotypic differences. The percentage of functional clones was similar in both groups. All clones tested were CCR5-tropic and showed comparable expression and fusogenic activity. Moreover, no differences were observed in their capacity to induce NKp44L expression on CD4 T cells from healthy donors through the 3S epitope of gp41. In contrast, anti- Env antibodies showed clear functional differences: plasma from VNPs had significantly higher capacity than RPs to block NKp44L induction by autologous viruses. Consistently, CD4 T-cells isolated from VNPs showed undetectable NKp44L expression and specific antibodies against a variable region flanking the highly conserved 3S epitope were identified in plasma samples from these patients. Conversely, despite continuous antigen stimulation, VNPs were unable to mount a broad neutralizing response against HIV. Conclusions Env functions (fusion and induction of NKp44L) were similar in viremic patients with slow or rapid progression to AIDS. However, differences in humoral responses against gp41 epitopes nearby 3S sequence may contribute to the lack

  12. Similar fecal immunochemical test results in screening and referral colorectal cancer

    PubMed Central

    van Turenhout, Sietze T; van Rossum, Leo GM; Oort, Frank A; Laheij, Robert JF; van Rijn, Anne F; Terhaar sive Droste, Jochim S; Fockens, Paul; van der Hulst, René WM; Bouman, Anneke A; Jansen, Jan BMJ; Meijer, Gerrit A; Dekker, Evelien; Mulder, Chris JJ

    2012-01-01

    AIM: To improve the interpretation of fecal immunochemical test (FIT) results in colorectal cancer (CRC) cases from screening and referral cohorts. METHODS: In this comparative observational study, two prospective cohorts of CRC cases were compared. The first cohort was obtained from 10 322 average risk subjects invited for CRC screening with FIT, of which, only subjects with a positive FIT were referred for colonoscopy. The second cohort was obtained from 3637 subjects scheduled for elective colonoscopy with a positive FIT result. The same FIT and positivity threshold (OC sensor; ≥ 50 ng/mL) was used in both cohorts. Colonoscopy was performed in all referral subjects and in FIT positive screening subjects. All CRC cases were selected from both cohorts. Outcome measurements were mean FIT results and FIT scores per tissue tumor stage (T stage). RESULTS: One hundred and eighteen patients with CRC were included in the present study: 28 cases obtained from the screening cohort (64% male; mean age 65 years, SD 6.5) and 90 cases obtained from the referral cohort (58% male; mean age 69 years, SD 9.8). The mean FIT results found were higher in the referral cohort (829 ± 302 ng/mL vs 613 ± 368 ng/mL, P = 0.02). Tissue tumor stage (T stage) distribution was different between both populations [screening population: 13 (46%) T1, eight (29%) T2, six (21%) T3, one (4%) T4 carcinoma; referral population: 12 (13%) T1, 22 (24%) T2, 52 (58%) T3, four (4%) T4 carcinoma], and higher T stage was significantly associated with higher FIT results (P < 0.001). Per tumor stage, no significant difference in mean FIT results was observed (screening vs referral: T1 498 ± 382 ng/mL vs 725 ± 374 ng/mL, P = 0.22; T2 787 ± 303 ng/mL vs 794 ± 341 ng/mL, P = 0.79; T3 563 ± 368 ng/mL vs 870 ± 258 ng/mL, P = 0.13; T4 not available). After correction for T stage in logistic regression analysis, no significant differences in mean FIT results were observed between both types of cohorts (P = 0

  13. Low-speed wind tunnel test results of the Canard Rotor/Wing concept

    NASA Technical Reports Server (NTRS)

    Bass, Steven M.; Thompson, Thomas L.; Rutherford, John W.; Swanson, Stephen

    1993-01-01

    The Canard Rotor/Wing (CRW), a high-speed rotorcraft concept, was tested at the National Aeronautics and Space Administration (NASA) Ames Research Center's 40- by 80-Foot Wind Tunnel in Mountain View, California. The 1/5-scale model was tested to identify certain low-speed, fixed-wing, aerodynamic characteristics of the configuration and investigate the effectiveness of two empennages, an H-Tail and a T-Tail. The paper addresses the principal test objectives and the results achieved in the wind tunnel test. These are summarized as: i) drag build-up and differences between the H-Tail and T-Tail configuration, ii) longitudinal stability of the H-Tail and T-Tail configurations in the conversion and cruise modes, iii) control derivatives for the canard and elevator in the conversion and cruise modes, iv) aerodynamic characteristics of varying the rotor/wing azimuth position, and v) canard and tail lift/trim capability for conversion conditions.

  14. Boeing's STAR-FODB test results

    NASA Astrophysics Data System (ADS)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  15. Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taxvig, Camilla, E-mail: camta@food.dtu.dk; Olesen, Pelle Thonning; Nellemann, Christine

    2011-02-01

    Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenousmore » metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.« less

  16. Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay.

    PubMed

    Taxvig, Camilla; Olesen, Pelle Thonning; Nellemann, Christine

    2011-02-01

    Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. 40 CFR Appendix I to Subpart T of... - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Results I Appendix I to Subpart T of Part 86 Protection of Environment ENVIRONMENTAL PROTECTION... Appendix I to Subpart T of Part 86—Sample Graphical Summary of NTE Emission Results The following figure shows an example of a graphical summary of NTE emission results: ER14JN05.002 ...

  18. HIFiRE-5 Flight Test Preliminary Results (Postprint)

    DTIC Science & Technology

    2013-11-01

    DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test article leading edge...Reference System (DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test...pitch angle relative to earth as measured by IMU , or flight-path elevation angle as measured by GPS or IMU , degrees  = body-fixed angular coordinate

  19. Flight Test Results for Uniquely Tailored Propulsion-Airframe Aeroacoustic Chevrons: Shockcell Noise

    NASA Technical Reports Server (NTRS)

    Mengle, Vinod G.; Ganz, Ulrich W.; Nesbitt, Eric; Bultemeier, Eric J.; Thomas, Russell H.; Nesbitt, Eric

    2006-01-01

    Azimuthally varying chevrons (AVC) which have been uniquely tailored to account for the asymmetric propulsion-airframe aeroacoustic interactions have recently shown significant reductions in jet-related community noise at low-speed take-off conditions in scale model tests of coaxial nozzles with high bypass ratio. There were indications that such AVCs may also provide shockcell noise reductions at high cruise speeds. This paper describes the flight test results when one such AVC concept, namely, the T-fan chevrons with enhanced mixing near the pylon, was tested at full-scale on a modern large twin-jet aircraft (777-300ER) with focus on shockcell noise at mid-cruise conditions. Shockcell noise is part of the interior cabin noise at cruise conditions and its reduction is useful from the viewpoint of passenger comfort. Noise reduction at the source, in the exhaust jet, especially, at low frequencies, is beneficial from the perspective of reduced fuselage sidewall acoustic lining. Results are shown in terms of unsteady pressure spectra both on the exterior surface of the fuselage at several axial stations and also microphone arrays placed inside the fuselage aft of the engine. The benefits of T-fan chevrons, with and without conventional chevrons on the core nozzle, are shown for several engine operating conditions at cruise involving supersonic fan stream and subsonic or supersonic core stream. The T-fan AVC alone provides up to 5 dB low-frequency noise reduction on the fuselage exterior skin and up to 2 dB reduction inside the cabin. Addition of core chevrons appears to increase the higher frequency noise. This flight test result with the previous model test observation that the T-fan AVCs have hardly any cruise thrust coefficient loss (< 0.05%) make them viable candidates for reducing interior cabin noise in high bypass ratio engines.

  20. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures - Test Results

    NASA Technical Reports Server (NTRS)

    Wright, Sarah E.; Ungar, Eugene K.

    2017-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.

  1. Flight Test Results for Uniquely Tailored Propulsion-Airframe Aeroacoustic Chevrons: Community Noise

    NASA Technical Reports Server (NTRS)

    Nesbitt, Eric; Mengle, Vinod; Czech, Michael; Callendar, Bryan; Thomas, Russ

    2006-01-01

    The flow/acoustic environment around the jet exhaust of an engine when installed on an airplane, say, under the wing, is highly asymmetric due to the pylon, the wing and the high-lift devices. Recent scale model tests have shown that such Propulsion Airframe Aeroacoustic (PAA) interactions and the jet mixing noise can be reduced more than with conventional azimuthally uniform chevrons by uniquely tailoring the chevrons to produce enhanced mixing near the pylon. This paper describes the community noise results from a flight test on a large twin-engine airplane using this concept of azimuthally varying chevrons for engines installed under the wing. Results for two different nozzle configurations are described: azimuthally varying "PAA T-fan" chevrons on the fan nozzle with a baseline no-chevron core nozzle and a second with PAA T-fan chevrons with conventional azimuthally uniform chevrons on the core nozzle. We analyze these test results in comparison to the baseline no-chevron nozzle on both spectral and integrated power level bases. The study focuses on the peak jet noise reduction and the effects at high frequencies for typical take-off power settings. The noise reduction and the absolute noise levels are then compared to model scale results. The flight test results verify that the PAA T-fan nozzles in combination with standard core chevron nozzles can, indeed, give a reasonable amount of noise reduction at low frequencies without high-frequency lift during take-off conditions and hardly any impact on the cruise thrust coefficient.

  2. 40 CFR Appendix I to Subpart T of... - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Results I Appendix I to Subpart T of Part 86 Protection of Environment ENVIRONMENTAL PROTECTION..., App. I Appendix I to Subpart T of Part 86—Sample Graphical Summary of NTE Emission Results The following figure shows an example of a graphical summary of NTE emission results: ER14JN05.002 ...

  3. Research project shows importance of pre-employment hearing testing.

    PubMed

    Karlovich, R S

    1992-02-01

    Forty employees received pure-tone baseline hearing tests at the time they began employment as LSM operators for the U.S. Postal Services; the workplace eight-hour average sound level (TWA) was 85 dBA. Nineteen operators from the original group had their hearing retested three years later. None of the retested subjects showed large or systematic changes in hearing sensitivity over the three-year period. For the audiometric frequencies most susceptible to noise exposure (3000, 4000, 6000 Hz), only 5 percent of the operators showed a bilateral change in threshold greater than 5 dB at any frequency, and none of them showed more than a 10 dB threshold change in both ears. None of the operators displayed a Standard Threshold Shift as described by OSHA. The data further suggested that many workers began their LSM work assignment with a pre-existing hearing loss and, based upon audiometric and history information, the impairment probably resulted from prior occupational and/or nonoccupational noise exposure. The importance of hearing-conservation programs for employees is emphasized.

  4. Increased autophagy in CD4+ T cells of rheumatoid arthritis patients results in T-cell hyperactivation and apoptosis resistance.

    PubMed

    van Loosdregt, Jorg; Rossetti, Maura; Spreafico, Roberto; Moshref, Maryam; Olmer, Merissa; Williams, Gary W; Kumar, Pavanish; Copeland, Dana; Pischel, Ken; Lotz, Martin; Albani, Salvatore

    2016-12-01

    Rheumatoid arthritis (RA) is an autoimmune disease hallmarked by aberrant cellular homeostasis, resulting in hyperactive CD4 + T cells that are more resistant to apoptosis. Both hyperactivation and resistance to apoptosis may contribute to the pathogenicity of CD4 + T cells in the autoimmune process. A better knowledge of the mechanisms determining such impaired homeostasis could contribute significantly to both the understanding and the treatment of the disease. Here we investigated whether autophagy, is dysregulated in CD4 + T cells of RA patients, resulting in disturbed T-cell homeostasis. We demonstrate that the rate of autophagy is significantly increased in CD4 + T cells from RA patients, and that increased autophagy is also a feature of in vitro activated CD4 + T cells. The increased apoptosis resistance observed in CD4 + T cells from RA patients was significantly reversed upon autophagy inhibition. These mechanisms may contribute to RA pathogenesis, as autophagy inhibition reduced both arthritis incidence and disease severity in a mouse collagen induced arthritis mouse model. Conversely, in Atg5 flox/flox -CD4-Cre + mice, in which all T cells are autophagy deficient, T cells showed impaired activation and proliferation. These data provide novel insight into the pathogenesis of RA and underscore the relevance of autophagy as a promising therapeutic target. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Quantitative T2-Mapping and T2⁎-Mapping Evaluation of Changes in Cartilage Matrix after Acute Anterior Cruciate Ligament Rupture and the Correlation between the Results of Both Methods

    PubMed Central

    Tao, Hongyue; Qiao, Yang; Hu, Yiwen; Xie, Yuxue; Lu, Rong; Yan, Xu

    2018-01-01

    Objectives To quantitatively assess changes in cartilage matrix after acute anterior cruciate ligament (ACL) rupture using T2- and T2⁎-mapping and analyze the correlation between the results of both methods. Methods Twenty-three patients and 23 healthy controls were enrolled and underwent quantitative MRI examination. The knee cartilage was segmented into six compartments, including lateral femur (LF), lateral tibia (LT), medial femur (MF), medial tibia (MT), trochlea (Tr), and patella (Pa). T2 and T2⁎ values were measured in full-thickness as well as superficial and deep layers of each cartilage compartment. Differences of T2 and T2⁎ values between patients and controls were compared using unpaired Student's t-test, and the correlation between their reciprocals was analyzed using Pearson's correlation coefficient. Results ACL-ruptured patients showed higher T2 and T2⁎ values in full-thickness and superficial layers of medial and lateral tibiofemoral joint. Meanwhile, patients exhibited higher T2⁎ values in deep layers of lateral tibiofemoral joint. The elevated percentages of T2 and T2⁎ value in superficial LT were most significant (20.738%, 17.525%). The reciprocal of T2⁎ value was correlated with that of T2 value (r = 0.886, P < 0.001). Conclusion The early degeneration could occur in various knee cartilage compartments after acute ACL rupture, especially in the superficial layer of LT. T2⁎-mapping might be more sensitive in detecting deep layer of cartilage than T2-mapping. PMID:29888279

  6. B-52 control configured vehicles: Flight test results

    NASA Technical Reports Server (NTRS)

    Arnold, J. I.; Murphy, F. B.

    1976-01-01

    Recently completed B-52 Control Configured Vehicles (CCV) flight testing is summarized, and results are compared to analytical predictions. Results are presented for five CCV system concepts: ride control, maneuver load control, flutter mode control, augmented stability, and fatigue reduction. Test results confirm analytical predictions and show that CCV system concepts achieve performance goals when operated individually or collectively.

  7. Test Results for Entry Guidance Methods for Reusable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.

    2003-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies (ITAGCT) has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future reusable vehicle concepts.

  8. Bayesian Estimation Supersedes the "t" Test

    ERIC Educational Resources Information Center

    Kruschke, John K.

    2013-01-01

    Bayesian estimation for 2 groups provides complete distributions of credible values for the effect size, group means and their difference, standard deviations and their difference, and the normality of the data. The method handles outliers. The decision rule can accept the null value (unlike traditional "t" tests) when certainty in the estimate is…

  9. 3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND 1-5 AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-4, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  10. CAR T-cell therapy for glioblastoma: ready for the next round of clinical testing?

    PubMed

    Prinzing, Brooke L; Gottschalk, Stephen M; Krenciute, Giedre

    2018-05-01

    The outcome for patients with glioblastoma (GBM) remains poor, and there is an urgent need to develop novel therapeutic approaches. T cells genetically modified with chimeric antigen receptors (CARs) hold the promise to improve outcomes since they recognize and kill cells through different mechanisms than conventional therapeutics. Areas covered: This article reviews CAR design, tumor associated antigens expressed by GBMs that can be targeted with CAR T cells, preclinical and clinical studies conducted with CAR T cells, and genetic approaches to enhance their effector function. Expert commentary: While preclinical studies have highlighted the potent anti-GBM activity of CAR T cells, the initial foray of CAR T-cell therapies into the clinic resulted only in limited benefits for GBM patients. Additional genetic modification of CAR T cells has resulted in a significant increase in their anti-GBM activity in preclinical models. We are optimistic that clinical testing of these enhanced CAR T cells will be safe and result in improved anti-glioma activity in GBM patients.

  11. Test Plan Procedure for Experiment T-003

    DOT National Transportation Integrated Search

    1971-05-19

    This document defines the type, sequence, and procedural details required to perform each test on the T-003 experiment aerosol analyzer, its subsystems and components. This plan utilizes the flexibility allowed for instruments in criticality category...

  12. Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Sweterlitsch, Jeffrey

    2011-01-01

    A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.

  13. Preliminary result of the analysis of T Sagittarrii data and modeling

    NASA Astrophysics Data System (ADS)

    Menut, Jean-Luc; Chesneau, Olivier; Lopez, Bruno; Berruyer, Nicole; Graser, Uwe; Niccolini, Gilles; Dutrey, Anne; Perrin, Guy S.

    2004-10-01

    This document shows the first results of the study of the environment of the S star T Sagittarii. Observational constraints are obtained through 10 μm long baseline interferometry with MIDI at the VLTI. Models of the dust envelope are simulated with a monte-carlo radiative transfer code.

  14. Btu accounting: Showing results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, K.E.

    1994-10-01

    In the preceding article in this series last month, the author showed how to calculate the energy consumed to make a pound of product. To realize a payoff, however, the results must be presented in graphs or tables that clearly display what has happened. They must call attention to plant performance and ultimately lead to more efficient use of energy. Energy-consumption reporting is particularly valuable when viewed over a period of time. The author recommend compiling data annually and maintaining a ten-year performance history. Four cases are considered: individual plant performance; site performance for sites having more than one plant;more » company performance, for companies having more than one site; and performance based on product, for identical or similar products made at different plants or sites. Of these, individual plant performance is inherently the most useful. It also serves as the best basis for site, company and product performance reports. A key element in energy accounting is the relating of all energy consumption to a common basis. As developed last month in Part 1 in this series, the author chose Btu[sub meth] (i.e., Btu of methane equivalent, expressed as its higher heating value) for this purpose. It represents the amount of methane that would be needed to replace (in the case of fuels) or generate (in the case of steam and power) the energy being used.« less

  15. Phosphoproteomics analyses show subnetwork systems in T-cell receptor signaling.

    PubMed

    Hatano, Atsushi; Matsumoto, Masaki; Nakayama, Keiichi I

    2016-10-01

    A key issue in the study of signal transduction is how multiple signaling pathways are systematically integrated into the cell. We have now performed multiple phosphoproteomics analyses focused on the dynamics of the T-cell receptor (TCR) signaling network and its subsystem mediated by the Ca 2+ signaling pathway. Integration of these phosphoproteomics data sets and extraction of components of the TCR signaling network dependent on Ca 2+ signaling showed unexpected phosphorylation kinetics for candidate substrates of the Ca 2+ -dependent phosphatase calcineurin (CN) during TCR stimulation. Detailed characterization of the TCR-induced phosphorylation of a novel CN substrate, Itpkb, showed that phosphorylation of this protein is regulated by both CN and the mitogen-activated protein kinase Erk in a competitive manner. Phosphorylation of additional CN substrates was also found to be regulated by Erk and CN in a similar manner. The combination of multiple phosphoproteomics approaches thus showed two major subsystems mediated by Erk and CN in the TCR signaling network, with these subsystems regulating the phosphorylation of a group of proteins in a competitive manner. © 2016 Molecular Biology Society of Japan and John Wiley & Sons Australia, Ltd.

  16. Improving tRNAscan-SE Annotation Results via Ensemble Classifiers.

    PubMed

    Zou, Quan; Guo, Jiasheng; Ju, Ying; Wu, Meihong; Zeng, Xiangxiang; Hong, Zhiling

    2015-11-01

    tRNAScan-SE is a tRNA detection program that is widely used for tRNA annotation; however, the false positive rate of tRNAScan-SE is unacceptable for large sequences. Here, we used a machine learning method to try to improve the tRNAScan-SE results. A new predictor, tRNA-Predict, was designed. We obtained real and pseudo-tRNA sequences as training data sets using tRNAScan-SE and constructed three different tRNA feature sets. We then set up an ensemble classifier, LibMutil, to predict tRNAs from the training data. The positive data set of 623 tRNA sequences was obtained from tRNAdb 2009 and the negative data set was the false positive tRNAs predicted by tRNAscan-SE. Our in silico experiments revealed a prediction accuracy rate of 95.1 % for tRNA-Predict using 10-fold cross-validation. tRNA-Predict was developed to distinguish functional tRNAs from pseudo-tRNAs rather than to predict tRNAs from a genome-wide scan. However, tRNA-Predict can work with the output of tRNAscan-SE, which is a genome-wide scanning method, to improve the tRNAscan-SE annotation results. The tRNA-Predict web server is accessible at http://datamining.xmu.edu.cn/∼gjs/tRNA-Predict. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. EBOLA Ag K-SeT rapid test: field evaluation in Sierra Leone.

    PubMed

    Colavita, F; Biava, M; Mertens, P; Gilleman, Q; Borlon, C; Delli Guanti, M; Petrocelli, A; Cataldi, G; Kamara, A T; Kamara, S A; Konneh, K; Vincenti, D; Castilletti, C; Abdurahman, S; Mirazimi, A; Capobianchi, M R; Ippolito, G; Miccio, R; Di Caro, A

    2018-06-01

    Efficient interruption of Ebola virus disease (EVD) transmission chains critically depends on reliable and fast laboratory diagnosis. We evaluated the performance of the EBOLA Virus Antigen Detection K-SeT (EBOLA Ag K-SeT), a new rapid diagnostic antigen test in field settings. The study was conducted in a field laboratory located in Freetown (Sierra Leone) by the Italian National Institute for Infectious Diseases 'L. Spallanzani' and the EMERGENCY Onlus NGO. The EBOLA Ag K-SeT was tested on 210 residual plasma samples (EVD prevalence 50%) from patients hospitalized at the EMERGENCY Ebola treatment center in Goderich (Freetown), comparing the results with quantitative real-time PCR. Overall, the sensitivity of EBOLA Ag K-SeT was 88.6% (95% confidence interval (CI), 82.5-94.7), and the corresponding specificity was 98.1% (95% CI, 95.5-100.7). The positive and negative predictive values were 97.9% (95% CI, 95.0-100.8) and 89.6% (95% CI, 84-95.2), respectively. The sensitivity strongly increased up to 98.7% (95% CI, 96.1-101.2) for those samples with high virus load (≥6.2 log RNA copies/mL). Our results suggest that EBOLA Ag K-SeT could represent a new effective diagnostic tool for EVD, meeting a need for resource-poor settings and rapid diagnosis for individuals with suspected EVD. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  18. Anti-anxiety activity of successive extracts of Angelica archangelica Linn. on the elevated T-maze and forced swimming tests in rats.

    PubMed

    Kumar, Dinesh; Bhat, Zulfiqar Ali; Shah, M Y

    2012-09-01

    Angelica archangelica Linn. is widely used in food and liquor preparations and also in Kashmiri folk medicine to reduce anxiety. We evaluated the anxiolytic effect of successive extracts of A. archangelica linn. (SAE) on rats tested in the elevated T-maze test (an animal model of generalized anxiety) at doses that exhibit antidepressant-like activity in humans. A. archangelica (1 kg) was subjected to successive extraction in a soxhlet apparatus with solvents [petroleum ether (40-60 degrees C), chloroform, ethyl acetate, methanol and decoction with water] in order of increasing polarity (yield: 6.9%, 7.3%, 5.1%, 11.88% and 8.2% w/w, respectively). SAE were evaluated for anxiolytic effects using the elevated T-maze and forced swimming tests in rats. Oral dosing of diazepam (1 mg/kg) and extracts (50, 100 and 200 mg/kg) clearly showed an anxiolytic-like profile in the elevated T-maze test: it increased one-way escape and decreased inhibitory avoidance on the first, third and seventh day. In the forced swimming test, imipramine and SAE showed antidepressant- and anxiolytic-like effects as reflected by increased climbing time, swimming time and decreased immobility time on the first, third and seventh day. Aqueous and methanol extracts showed the most, petroleum ether (40-60 degrees C) and chloroform intermediate, and ethyl acetate the least anxiolytic activity (*P<0.05, **P<0.01, ***P< 0.001) in both models. These results suggest the anti-anxiety activity of various extracts of A. archangelica and strongly justify its use in traditional Indian medicine for the treatment of anxiety.

  19. Detail of north side of Test Stand 'A' base, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of north side of Test Stand 'A' base, showing tanks for distilled water (left), fuel (center), and gaseous nitrogen (right). Other tanks present for tests were removed before this image was taken. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  20. Multivariate Welch t-test on distances

    PubMed Central

    2016-01-01

    Motivation: Permutational non-Euclidean analysis of variance, PERMANOVA, is routinely used in exploratory analysis of multivariate datasets to draw conclusions about the significance of patterns visualized through dimension reduction. This method recognizes that pairwise distance matrix between observations is sufficient to compute within and between group sums of squares necessary to form the (pseudo) F statistic. Moreover, not only Euclidean, but arbitrary distances can be used. This method, however, suffers from loss of power and type I error inflation in the presence of heteroscedasticity and sample size imbalances. Results: We develop a solution in the form of a distance-based Welch t-test, TW2, for two sample potentially unbalanced and heteroscedastic data. We demonstrate empirically the desirable type I error and power characteristics of the new test. We compare the performance of PERMANOVA and TW2 in reanalysis of two existing microbiome datasets, where the methodology has originated. Availability and Implementation: The source code for methods and analysis of this article is available at https://github.com/alekseyenko/Tw2. Further guidance on application of these methods can be obtained from the author. Contact: alekseye@musc.edu PMID:27515741

  1. 9.4T Human MRI: Preliminary Results

    PubMed Central

    Vaughan, Thomas; DelaBarre, Lance; Snyder, Carl; Tian, Jinfeng; Akgun, Can; Shrivastava, Devashish; Liu, Wanzahn; Olson, Chris; Adriany, Gregor; Strupp, John; Andersen, Peter; Gopinath, Anand; van de Moortele, Pierre-Francois; Garwood, Michael; Ugurbil, Kamil

    2014-01-01

    This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T. PMID:17075852

  2. 2. ROCKET ENGINE TEST STAND, SHOWING TANK (BUILDING 1929) AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ROCKET ENGINE TEST STAND, SHOWING TANK (BUILDING 1929) AND GARAGE (BUILDING 1930) AT LEFT REAR. Looking to west. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  3. Ball Aerospace SBMD Coating Test Results

    NASA Technical Reports Server (NTRS)

    Brown, Robert; Lightsey, Paul; Russell, J. Kevin (Technical Monitor)

    2002-01-01

    The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

  4. 7. INTERIOR VIEW, SHOWING PROPELLER TEST STAND AND BOMB BAYS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. INTERIOR VIEW, SHOWING PROPELLER TEST STAND AND BOMB BAYS. - Wright-Patterson Air Force Base, Area B, Building No. 20A, Propeller Test Complex, Seventh Street, from E to G Streets, Dayton, Montgomery County, OH

  5. 5. INTERIOR VIEW, SHOWING PROPELLER TEST STAND AND BOMB BAYS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INTERIOR VIEW, SHOWING PROPELLER TEST STAND AND BOMB BAYS. - Wright-Patterson Air Force Base, Area B, Building No. 20A, Propeller Test Complex, Seventh Street, from E to G Streets, Dayton, Montgomery County, OH

  6. 17. Building 202, observation room for test cell, showing panel, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Building 202, observation room for test cell, showing panel, abort button, phones, and observation window. View looking northwest. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  7. The Dichotic Digits difference Test (DDdT): Development, Normative Data, and Test-Retest Reliability Studies Part 1.

    PubMed

    Cameron, Sharon; Glyde, Helen; Dillon, Harvey; Whitfield, Jessica; Seymour, John

    2016-06-01

    The dichotic digits test is one of the most widely used assessment tools for central auditory processing disorder. However, questions remain concerning the impact of cognitive factors on test results. To develop the Dichotic Digits difference Test (DDdT), an assessment tool that could differentiate children with cognitive deficits from children with genuine dichotic deficits based on differential test results. The DDdT consists of four subtests: dichotic free recall (FR), dichotic directed left ear (DLE), dichotic directed right ear (DRE), and diotic. Scores for six conditions are calculated (FR left ear [LE], FR right ear [RE], and FR total, as well as DLE, DRE, and diotic). Scores for four difference measures are also calculated: dichotic advantage, right-ear advantage (REA) FR, REA directed, and attention advantage. Experiment 1 involved development of the DDdT, including error rate analysis. Experiment 2 involved collection of normative and test-retest reliability data. Twenty adults (aged 25 yr 10 mo to 50 yr 7 mo, mean 36 yr 4 mo) took part in the development study; 62 normal-hearing, typically developing, primary-school children (aged 7 yr 1 mo to 11 yr 11 mo, mean 9 yr 4 mo) and 10 adults (aged 25 yr 0 mo to 51 yr 6 mo, mean 34 yr 10 mo) took part in the normative and test-retest reliability study. In Experiment 1, error rate analysis was conducted on the 36 digit-pair combinations of the DDdT. Normative data collected in Experiment 2 were arcsine transformed to achieve a distribution that was closer to a normal distribution and z-scores calculated. Pearson product-moment correlations were used to determine the strength of relationships between DDdT conditions. The development study revealed no significant differences in the adult population between test and retest on any DDdT condition. Error rates on 36 digit pairs ranged from 1.5% to 16.7%. The most and the least error-prone digits were removed before commencement of the normative data study, leaving 25

  8. 39. Historic photo of Building 202 test cell exterior, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. Historic photo of Building 202 test cell exterior, showing fiberglass cladding blown out by hydrogen fire during rocket engine testing, April 27, 1959. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-50472. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  9. Module Hipot and ground continuity test results

    NASA Technical Reports Server (NTRS)

    Griffith, J. S.

    1984-01-01

    Hipot (high voltage potential) and module frame continuity tests of solar energy conversion modules intended for deployment into large arrays are discussed. The purpose of the tests is to reveal potentially hazardous voltage conditions in installed modules, and leakage currents that may result in loss of power or cause ground fault system problems, i.e., current leakage potential and leakage voltage distribution. The tests show a combined failure rate of 36% (69% when environmental testing is included). These failure rates are believed easily corrected by greater care in fabrication.

  10. Bench-Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Sweterlitsch, Jeff

    2011-01-01

    A principal concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has been evaluated for use in this application and several programs are evaluating it for use in both cabin and space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of bench-scale SA9T testing that was performed under a variety of test conditions and with several different trace contaminants. Tests were conducted to determine if the capacity of the SA9T media to sufficiently remove CO2 and H2O is compromised after exposure to a fully saturated trace contaminant at ambient conditions. Tests also were conducted to evaluate the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream. In addition, testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures (29.6 KPa/4.3 psia) during cyclic operation with a constant inlet contaminant load.

  11. MASH test 3-11 on the Texas T101 bridge rail

    DOT National Transportation Integrated Search

    2011-03-01

    The Texas T101 bridge rail is widely used in the state of Texas. Previous testing demonstrated its ability to contain and redirect passenger cars and a 20,000-lb school bus. Based on this testing, the Federal Highway Administration accepted the T101 ...

  12. 38. Historic photo of Building 202 test cell interior, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. Historic photo of Building 202 test cell interior, showing damage to test stand A and rocket engine after failure and explosion of engine, December 12, 1958. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-49376. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  13. Metacognitive Ability Relationship with Test Result of Senior High School of Biology Teacher Competence in Sijunjung District

    NASA Astrophysics Data System (ADS)

    Ardi, A.; Fadilah, M.; Ichsani, W.

    2018-04-01

    This research aimed to reveal how the relationship between metacognitive ability and the test result of biology teacher competence in Sijunjung District. The population of this descriptive research were all high school biology teachers in Sijunjung District, and sample is all teachers who are members of the population, which is 23 biology teachers. The instrument used in this research are a questionnaire of research on teacher's metacognitive ability and document about teacher competence test result. The questionnaire was validated first by two lecturers of biology and one lecturer of English. Data analysis using Pearson Product Moment's. Based on the results of research and discussion that have been described, it can generally be concluded that there is a low relationship between metacognitive ability with competence test results of high school biology teachers in Sijunjung District. Partially, the relationship of metacognitive ability with the test result of professional competence of biology teacher showed significant result, with correlation coefficient 0,46 and t table 1,72 while titung 2,37. The contribution of metacognitive ability to the competence test result of the teacher is 21.6%, while the other 78.4% have not been revealed in this research.

  14. Prior irradiation results in elevated programmed cell death protein 1 (PD-1) in T cells.

    PubMed

    Li, Deguan; Chen, Renxiang; Wang, Yi-Wen; Fornace, Albert J; Li, Heng-Hong

    2018-05-01

    In this study we addressed the question whether radiation-induced adverse effects on T cell activation are associated with alterations of T cell checkpoint receptors. Expression levels of checkpoint receptors on T cell subpopulations were analyzed at multiple post-radiation time points ranging from one to four weeks in mice receiving a single fraction of 1 or 4 Gy of γ-ray. T cell activation associated metabolic changes were assessed. Our results showed that prior irradiation resulted in significant elevated expression of programmed cell death protein 1 (PD-1) in both CD4+ and CD8+ populations, at all three post-radiation time points. T cells with elevated PD-1 mostly were either central memory or naïve cells. In addition, the feedback induction of PD-1 expression in activated T cells declined after radiation. Taken together, the elevated PD-1 level observed at weeks after radiation exposure is connected to T cell dysfunction. Recent preclinical and clinical studies have showed that a combination of radiotherapy and T cell checkpoint blockade immunotherapy including targeting the programmed death-ligand 1 (PD-L1)/PD-1 axis may potentiate the antitumor response. Understanding the dynamic changes in PD-1 levels in T cells after radiation should help in the development of a more effective therapeutic strategy.

  15. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.

    PubMed

    Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J

    2005-02-01

    Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

  16. Investigating CSI: portrayals of DNA testing on a forensic crime show and their potential effects.

    PubMed

    Ley, Barbara L; Jankowski, Natalie; Brewer, Paul R

    2012-01-01

    The popularity of forensic crime shows such as CSI has fueled debate about their potential social impact. This study considers CSI's potential effects on public understandings regarding DNA testing in the context of judicial processes, the policy debates surrounding crime laboratory procedures, and the forensic science profession, as well as an effect not discussed in previous accounts: namely, the show's potential impact on public understandings of DNA and genetics more generally. To develop a theoretical foundation for research on the "CSI effect," it draws on cultivation theory, social cognitive theory, and audience reception studies. It then uses content analysis and textual analysis to illuminate how the show depicts DNA testing. The results demonstrate that CSI tends to depict DNA testing as routine, swift, useful, and reliable and that it echoes broader discourses about genetics. At times, however, the show suggests more complex ways of thinking about DNA testing and genetics.

  17. Quantitative T2-Mapping and T2⁎-Mapping Evaluation of Changes in Cartilage Matrix after Acute Anterior Cruciate Ligament Rupture and the Correlation between the Results of Both Methods.

    PubMed

    Tao, Hongyue; Qiao, Yang; Hu, Yiwen; Xie, Yuxue; Lu, Rong; Yan, Xu; Chen, Shuang

    2018-01-01

    To quantitatively assess changes in cartilage matrix after acute anterior cruciate ligament (ACL) rupture using T2- and T2 ⁎ -mapping and analyze the correlation between the results of both methods. Twenty-three patients and 23 healthy controls were enrolled and underwent quantitative MRI examination. The knee cartilage was segmented into six compartments, including lateral femur (LF), lateral tibia (LT), medial femur (MF), medial tibia (MT), trochlea (Tr), and patella (Pa). T2 and T2 ⁎ values were measured in full-thickness as well as superficial and deep layers of each cartilage compartment. Differences of T2 and T2 ⁎ values between patients and controls were compared using unpaired Student's t -test, and the correlation between their reciprocals was analyzed using Pearson's correlation coefficient. ACL-ruptured patients showed higher T2 and T2 ⁎ values in full-thickness and superficial layers of medial and lateral tibiofemoral joint. Meanwhile, patients exhibited higher T2 ⁎ values in deep layers of lateral tibiofemoral joint. The elevated percentages of T2 and T2 ⁎ value in superficial LT were most significant (20.738%, 17.525%). The reciprocal of T2 ⁎ value was correlated with that of T2 value ( r = 0.886, P < 0.001). The early degeneration could occur in various knee cartilage compartments after acute ACL rupture, especially in the superficial layer of LT. T2 ⁎ -mapping might be more sensitive in detecting deep layer of cartilage than T2-mapping.

  18. 1. Photographic copy of engineering drawing showing structure of Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of engineering drawing showing structure of Test Stand 'B' (4215/E-16), also known as the 'Short Snorter.' California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Structural Addition - Bldg. E-12, Edwards Test Station,' drawing no. E12/1-1, 8 August 1957. - Jet Propulsion Laboratory Edwards Facility, Test Stand B, Edwards Air Force Base, Boron, Kern County, CA

  19. WASP (Write a Scientific Paper) using Excel - 8: t-Tests.

    PubMed

    Grech, Victor

    2018-06-01

    t-Testing is a common component of inferential statistics when comparing two means. This paper explains the central limit theorem and the concept of the null hypothesis as well as types of errors. On the practical side, this paper outlines how different t-tests may be performed in Microsoft Excel, for different purposes, both statically as well as dynamically, with Excel's functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Biaxial Testing of 2219-T87 Aluminum Alloy Using Cruciform Specimens

    NASA Technical Reports Server (NTRS)

    Dawicke, D. S.; Pollock, W. D.

    1997-01-01

    A cruciform biaxial test specimen was designed and seven biaxial tensile tests were conducted on 2219-T87 aluminum alloy. An elastic-plastic finite element analysis was used to simulate each tests and predict the yield stresses. The elastic-plastic finite analysis accurately simulated the measured load-strain behavior for each test. The yield stresses predicted by the finite element analyses indicated that the yield behavior of the 2219-T87 aluminum alloy agrees with the von Mises yield criterion.

  1. 1. EXTERIOR VIEW, LOOKING SOUTHEAST, SHOWING FLIGHT TEST HANGARS IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. EXTERIOR VIEW, LOOKING SOUTHEAST, SHOWING FLIGHT TEST HANGARS IN CENTER, BUILDING 7 ON LEFT, AND BUILDING 8 ON RIGHT. - Wright-Patterson Air Force Base, Area B, Building 1/9, Flight Test Hangars, On flightline between Ninth & Tenth Streets, Dayton, Montgomery County, OH

  2. 8. LOW OBLIQUE AERIAL VIEW OF TEST AREA 1115, SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. LOW OBLIQUE AERIAL VIEW OF TEST AREA 1-115, SHOWING TEST STANDS 1-5, 1-4, AND 1-3 (LEFT TO RIGHT). - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  3. 5. NORTH REAR, EAST PART, SHOWING ESCAPE HATCH. TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. NORTH REAR, EAST PART, SHOWING ESCAPE HATCH. TEST STAND 1-3 AND ITS MACHINE SHOP ARE IN MIDDLE DISTANCE. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  4. 40 CFR Appendix I to Subpart T - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Results I Appendix I to Subpart T Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Appendix I to Subpart T—Sample Graphical Summary of NTE Emission Results The following figure shows an example of a graphical summary of NTE emission results: ER14JN05.002 ...

  5. One-sided truncated sequential t-test: application to natural resource sampling

    Treesearch

    Gary W. Fowler; William G. O' Regan

    1974-01-01

    A new procedure for constructing one-sided truncated sequential t-tests and its application to natural resource sampling are described. Monte Carlo procedures were used to develop a series of one-sided truncated sequential t-tests and the associated approximations to the operating characteristic and average sample number functions. Different truncation points and...

  6. 8. X15 ENGINE TESTING. A color print showing the engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. X-15 ENGINE TESTING. A color print showing the engine during test firing. View from the rear of the test stand looking northwest. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  7. Update on results of SPRE testing at NASA Lewis

    NASA Technical Reports Server (NTRS)

    Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.

    1991-01-01

    The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigated the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The impact of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance tests results with HFAST code predictions show good agreement for PV power, but show poor agreement for PV efficiency. Correlations are presented relating the piston midstroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

  8. Stress Tests for Chest Pain: When You Need an Imaging Test -- and When You Don't

    MedlinePlus

    ... Resources Adult , Geriatric Stress Tests for Chest Pain Stress Tests for Chest Pain When you need an ... pain isn’t from heart disease. A cardiac stress test makes the heart work hard so your ...

  9. Interpretation and classification of microvolt T wave alternans tests

    NASA Technical Reports Server (NTRS)

    Bloomfield, Daniel M.; Hohnloser, Stefan H.; Cohen, Richard J.

    2002-01-01

    Measurement of microvolt-level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.

  10. Periodic Overload and Transport Spectrum Fatigue Crack Growth Tests of Ti62222STA and Al2024T3 Sheet

    NASA Technical Reports Server (NTRS)

    Phillips, Edward P.

    1999-01-01

    Variable amplitude loading crack growth tests have been conducted to provide data that can be used to evaluate crack growth prediction codes. Tests with periodic overloads or overloads followed by underloads were conducted on titanium alloy Ti-6Al-2Sn-2Zr-2Mo-2Cr solution treated and aged (Ti62222STA) material at room temperature and at 350 F. Spectrum fatigue crack growth tests were conducted on two materials (Ti62222STA and aluminum alloy 2024-T3) using two transport lower-wing test spectra at two temperatures (room temperature and 350 F (Ti only)). Test lives (growth from an initial crack half-length of 0.15 in. to failure) were recorded in all tests and the crack length against cycles (or flights) data were recorded in many of the tests. The following observations were made regarding the test results: (1) in tests of the Ti62222STA material, the tests at 350 F had longer lives than those at room temperature, (2) in tests to the MiniTwist spectrum, the Al2024T3 material showed much greater crack growth retardations due to the highest stresses in the spectrum than did the Ti62222STA material, and (3) comparisons of material crack growth performances on an "equal weight" basis were spectrum dependent.

  11. Testing for boosting at the Paralympic games: policies, results and future directions.

    PubMed

    Blauwet, Cheri A; Benjamin-Laing, Harry; Stomphorst, Jaap; Van de Vliet, Peter; Pit-Grosheide, Pia; Willick, Stuart E

    2013-09-01

    'Boosting' is defined as the intentional induction of autonomic dysreflexia (AD) by athletes with a spinal cord injury (SCI) at or above the level of T6 for the purpose of improving sports performance. Boosting has been shown to confer up to a 9.7% improvement in race time. Additionally, to compete in a hazardous dysreflexic state, whether intentional or unintentional, would present an extreme health risk to the athlete. For these reasons, the International Paralympic Committee strictly bans the practice of boosting, and has developed a protocol to test for its presence. Testing was performed at three major international Paralympic events. Education regarding the dangers of AD was provided to athletes and team staff. Testing was conducted on athletes from the relevant sport classes: Athletics (wheelchair racing classes T51/T52/T53) and Handcycling (H1). Key parameters included the athlete's demographics (gender, country of origin), classification and blood pressure measurements. An extremely elevated blood pressure was considered to be a proxy maker for AD, and a systolic blood pressure of ≥180 mm Hg was considered a positive test. A total of 78 tests for the presence of AD were performed during the three games combined. No athlete tested positive. The number of athletes tested, by classification, was: 6 in Athletics T51, 47 in Athletics T52, 9 in Athletics T53 and 16 in Handcycling H1. Of those tested, the average systolic and diastolic blood pressures were 135 mm Hg (range 98-178) and 82 mm Hg (range 44-112), respectively. All athletes were compliant with testing. No athletes were withdrawn from competition due to the presence of AD. Testing for the presence of AD in paralympic athletes with SCI prior to competition has been carried out for the first time at three major international paralympic competitions. There have been no positive tests thus far. Knowledge gained during these early testing experiences will be used to guide ongoing refinement of the testing

  12. Lipophilic Prodrugs of FR900098 Are Antimicrobial against Francisella novicida In Vivo and In Vitro and Show GlpT Independent Efficacy

    PubMed Central

    McKenney, Elizabeth S.; Sargent, Michelle; Khan, Hameed; Uh, Eugene; Jackson, Emily R.; Jose, Géraldine San; Couch, Robin D.; Dowd, Cynthia S.; van Hoek, Monique L.

    2012-01-01

    Bacteria, plants, and algae produce isoprenoids through the methylerythritol phosphate (MEP) pathway, an attractive pathway for antimicrobial drug development as it is present in prokaryotes and some lower eukaryotes but absent from human cells. The first committed step of the MEP pathway is catalyzed by 1-deoxy-D-xylulose 5-phosphate reductoisomerase (DXR/MEP synthase). MEP pathway genes have been identified in many biothreat agents, including Francisella, Brucella, Bacillus, Burkholderia, and Yersinia. The importance of the MEP pathway to Francisella is demonstrated by the fact that MEP pathway mutations are lethal. We have previously established that fosmidomycin inhibits purified MEP synthase (DXR) from F. tularensis LVS. FR900098, the acetyl derivative of fosmidomycin, was found to inhibit the activity of purified DXR from F. tularensis LVS (IC50 = 230 nM). Fosmidomycin and FR900098 are effective against purified DXR from Mycobacterium tuberculosis as well, but have no effect on whole cells because the compounds are too polar to penetrate the thick cell wall. Fosmidomycin requires the GlpT transporter to enter cells, and this is absent in some pathogens, including M. tuberculosis. In this study, we have identified the GlpT homologs in F. novicida and tested transposon insertion mutants of glpT. We showed that FR900098 also requires GlpT for full activity against F. novicida. Thus, we synthesized several FR900098 prodrugs that have lipophilic groups to facilitate their passage through the bacterial cell wall and bypass the requirement for the GlpT transporter. One compound, that we termed “compound 1,” was found to have GlpT-independent antimicrobial activity. We tested the ability of this best performing prodrug to inhibit F. novicida intracellular infection of eukaryotic cell lines and the caterpillar Galleria mellonella as an in vivo infection model. As a lipophilic GlpT-independent DXR inhibitor, compound 1 has the potential to be a broad

  13. Performance and blood monitoring in sports: the artificial intelligence evoking target testing in antidoping (AR.I.E.T.T.A.) project.

    PubMed

    Manfredini, A F; Malagoni, A M; Litmanen, H; Zhukovskaja, L; Jeannier, P; Dal Follo, D; Felisatti, M; Besseberg, A; Geistlinger, M; Bayer, P; Carrabre, J E

    2011-03-01

    Substances and methods used to increase oxygen blood transport and physical performance can be detected in the blood, but the screening of the athletes to be tested remains a critical issue for the International Federations. This project, AR.I.E.T.T.A., aimed to develop a software capable of analysing athletes' hematological and performance profiles to detect abnormal patterns. One-hundred eighty athletes belonging to the International Biathlon Union gave written informed consent to have their hematological data, previously collected according to anti-doping rules, used to develop the AR.I.E.T.T.A. software. Software was developed with the included sections: 1) log-in; 2) data-entry: where data are loaded, stored and grouped; 3) analysis: where data are analysed, validated scores are calculated, and parameters are simultaneously displayed as statistics, tables and graphs, and individual or subpopulation profiles; 4) screening: where an immediate evaluation of the risk score of the present sample and/or the athlete under study is obtained. The sample risk score or AR.I.E.T.T.A. score is calculated by a simple computational system combining different parameters (absolute values and intra-individual variations) considered concurrently. The AR.I.E.T.T.A. score is obtained by the sum of the deviation units derived from each parameter, considering the shift of the present value from the reference values, based on the number of standard deviations. AR.I.E.T.T.A. enables a quick evaluation of blood results assisting surveillance programs and perform timely target testing controls on athletes by the International Federations. Future studies aiming to validate the AR.I.E.T.T.A. score and improve the diagnostic accuracy will improve the system.

  14. The benefits of the 3T3 NRU test in the safety assessment of cosmetics: long-term experience from pre-marketing testing in the Czech Republic.

    PubMed

    Jírová, D; Kejlová, K; Brabec, M; Bendová, H; Kolárová, H

    2003-01-01

    We have introduced the 3T3 NRU cytotoxicity test for methodological, economical and ethical reasons as a regular part of tier pre-marketing testing to assess local tolerance of raw materials for cosmetics, household chemicals and final cosmetic products. Using the 3T3 cell line according to the standard INVITTOX protocol No.64 (NRU Assay) the borderline concentration, relevant to the highest tolerated dose, is determined for each material. The toxic effect is reached at different concentration levels specific for individual cosmetics categories, depending on their chemical characteristics. Typical ranges of cytotoxicity for specific categories of cosmetics were established after testing of hundreds of materials. The range lies between 1 microg/ml (anti-dandruff shampoos), up to 2000 microg/ml (toothpastes and mouthwashes). The 3T3 NRU cytotoxicity test is a sensitive tool able to identify more aggressive products, that are also more likely to evoke irritation in human skin. It was even possible to detect protective effects of one natural herbal ingredient. The comparative study of cytotoxicity test results and human patch test results from a group of essential oils is presented. Cytotoxicity tests represent a highly ethical approach for estimation of irritancy. On the basis of in vitro test results suggesting low risk we can proceed to confirmatory tests in human volunteers.

  15. 7. BUILDING 604F, INTERIOR OF BULL PEN SHOWING TESTING STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. BUILDING 604-F, INTERIOR OF BULL PEN SHOWING TESTING STAND AND HEAVY WOOD LINING ON CONCRETE WALLS. STEEL PLATE ABOVE TEST STAND DEFLECTS SHRAPNEL, SCREEN FURTHER HELPS TO CONTAIN PARTICLES. ONLY SMALL EXPLOSIVES WERE TESTED HERE (GRENADES, MINES, BOMB FUZES, ETC.). - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ

  16. Discordant prostate specific antigen test results despite WHO assay standardization.

    PubMed

    Boegemann, Martin; Arsov, Christian; Hadaschik, Boris; Herkommer, Kathleen; Imkamp, Florian; Nofer, Jerzy-Roch; Gerß, Joachim; Albers, Peter; Semjonow, Axel

    2018-05-01

    Total PSA (tPSA) and free PSA (fPSA) are the most commonly used biomarkers for early detection of prostate cancer. Despite standardization efforts, many available PSA assays may still produce discordant results. In the present study, we compared four PSA assays calibrated to the WHO standards 96/670 and 96/668 for tPSA and fPSA, respectively. Within the scope of the Prostate Cancer Early Detection Study Based on a ''Baseline'' PSA Value in Young Men (PROBASE), we tested tPSA and fPSA in serum samples from 50 patients in the four different PROBASE sites using four WHO-calibrated assays from Roche (Elecsys, Cobas), Beckman-Coulter (Access-II) and Siemens (ADVIA Centaur). The comparison was performed using the Passing-Bablok regression method. Compared to Access, the median tPSA levels for Centaur, Elecsys, and Cobas were +3%, +11%-20%, and +17%-23%, respectively, while for median fPSA levels the differences for Centaur, Elecsys, and Cobas were +49%, +29%-31%, and +22%, respectively. Despite all investigated assays being WHO-calibrated, the Elecsys and Cobas tPSA assays produced considerably higher results than the Access and Centaur assays. Differences in fPSA-recovery between all investigated assays were even more pronounced. When applying the tPSA cutoff of 3.1 μg/L recommended for WHO-calibrated assays, the use of higher calibrated assays may lead to unnecessary prostate biopsies. Conversely, if the historical threshold of 4 μg/L is applied when using WHO-calibrated assays, it could lead to falsely omitted prostate biopsies.

  17. New error calibration tests for gravity models using subset solutions and independent data - Applied to GEM-T3

    NASA Technical Reports Server (NTRS)

    Lerch, F. J.; Nerem, R. S.; Chinn, D. S.; Chan, J. C.; Patel, G. B.; Klosko, S. M.

    1993-01-01

    A new method has been developed to provide a direct test of the error calibrations of gravity models based on actual satellite observations. The basic approach projects the error estimates of the gravity model parameters onto satellite observations, and the results of these projections are then compared with data residual computed from the orbital fits. To allow specific testing of the gravity error calibrations, subset solutions are computed based on the data set and data weighting of the gravity model. The approach is demonstrated using GEM-T3 to show that the gravity error estimates are well calibrated and that reliable predictions of orbit accuracies can be achieved for independent orbits.

  18. Flight test results of riblets at supersonic speeds

    NASA Technical Reports Server (NTRS)

    Zuniga, Fanny A.; Anderson, Bianca T.; Bertelrud, Arild

    1992-01-01

    A flight experiment to test and evaluate the skin friction drag characteristics of a riblet surface in turbulent flow at supersonic speeds was conducted at NASA Dryden. Riblets of groove sizes 0.0030 and 0.0013 in. were mounted on the F-104G flight test fixture. The test surfaces were surveyed with boundary layer rakes and pressure orifices to examine the boundary layer profiles and pressure distributions of the flow. Skin friction reductions caused by the riblet surface were reported based on measured differences of momentum thickness between the smooth and riblet surfaces obtained from the boundary layer data. Flight test results for the 0.0030 in. riblet show skin friction reductions of 4 to 8 % for Mach numbers ranging from 1.2 to 1.6 and Reynolds numbers ranging from 2 to 3.4 million per unit foot. The results from the 0.0013 in. riblets show skin friction reductions of 4 to 15 % for Mach 1.2 to 1.4 and Reynolds numbers ranging from 3.6 to 6 million per unit foot.

  19. Test Results of Earth Penetrators

    DTIC Science & Technology

    1977-11-01

    34 1𔃺,,HI1rlt D’ .. ,..r rhb ’ i. ,.,..n " Ir ld t1 I ",,ll’ I ... hick lli Ihree test series were conducted to observe the stability of small length-to...241 1942 511 b3 NF2 2.6 Igo 1502 NF03 3.0 16 19635 V 104 2.1 41 2042 Be 40 PF,4 1.3 341 2043 to Is WF.4 2,8 ass 1833 53 VCF.5 all 11i 1759 34 - WEI

  20. Yawed-Rolling Tire Mechanical Properties Testing of the Navy T-45 Aircraft Tires

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.

    2000-01-01

    The T-45 Goshawk is a United States Navy Jet aircraft used primarily as a trainer. The aircraft design makes use of "off the shelf" hardware as much as possible and was found to have unusual directional control issues during around operations. The aircraft was involved in numerous pilot-induced-oscillation incidents as well as observed to have unusual directional control reactions to failed main gear tires, a condition that is normally handled relatively easily by conventional aircraft steering control techniques. The behavior of the aircraft's tires had previously been modeled in simulators as a result of approximations provided in 40-year-old reference publications. Since knowledge of the true tire cornering and braking behavior is essential to modeling, understanding, and fixing directional control problems, the United States Navy requested assistance from the NASA Langley Research Center's (LARC) Aircraft Landing Dynamics Facility (ALDF) to define the yawed-rolling mechanical properties of the T-45 aircraft tires. The purpose of this report is to document the results of testing the subject tires at the NASA LaRC ALDF in September 1998. Brief descriptions of the Instrumented Tire Test Vehicle (ITTV) are included to familiarize the reader with the ITTV capabilities, data acquisition system, test and measurement techniques, data accuracy, and analysis and presentation of the testing results.

  1. The right not to know HIV-test results.

    PubMed

    Temmerman, M; Ndinya-Achola, J; Ambani, J; Piot, P

    1995-04-15

    Large numbers of pregnant women in Africa have been invited to participate in studies on HIV infection. Study protocols adhere to guidelines on voluntary participation after pre-test and post-test counselling and informed consent; nevertheless, women may consent because they have been asked to do so without fully understanding the implications of being tested for HIV. Our studies in Nairobi, Kenya, show that most women tested after giving informed consent did not actively request their results, less than one third informed their partner, and violence against women because of a positive HIV-antibody test was common. It is important to have carefully designed protocols weighing the benefits against the potential harms for women participating in a study. Even after having consented to HIV testing, women should have the right not to be told their result.

  2. To t-Test or Not to t-Test? A p-Values-Based Point of View in the Receiver Operating Characteristic Curve Framework.

    PubMed

    Vexler, Albert; Yu, Jihnhee

    2018-04-13

    A common statistical doctrine supported by many introductory courses and textbooks is that t-test type procedures based on normally distributed data points are anticipated to provide a standard in decision-making. In order to motivate scholars to examine this convention, we introduce a simple approach based on graphical tools of receiver operating characteristic (ROC) curve analysis, a well-established biostatistical methodology. In this context, we propose employing a p-values-based method, taking into account the stochastic nature of p-values. We focus on the modern statistical literature to address the expected p-value (EPV) as a measure of the performance of decision-making rules. During the course of our study, we extend the EPV concept to be considered in terms of the ROC curve technique. This provides expressive evaluations and visualizations of a wide spectrum of testing mechanisms' properties. We show that the conventional power characterization of tests is a partial aspect of the presented EPV/ROC technique. We desire that this explanation of the EPV/ROC approach convinces researchers of the usefulness of the EPV/ROC approach for depicting different characteristics of decision-making procedures, in light of the growing interest regarding correct p-values-based applications.

  3. Comparison of cost-effectiveness between the quantiFERON-TB Gold-In-Tube and T-Spot tests for screening health-care workers for latent tuberculosis infection.

    PubMed

    Mukai, Shigeto; Shigemura, Katsumi; Yamamichi, Fukashi; Kitagawa, Koichi; Takami, Nozomi; Nomi, Masashi; Arakawa, Soichi; Fujisawa, Masato

    2017-01-01

    There are several methods used to screen for latent tuberculosis (TB) infection (LTBI) including the QuantiFERON-TB Gold-in-Tube (QFT-GIT) and T-SPOT-TB (T-SPOT) tests. Many studies have reported the equivalence of these two methods, but it is unclear which of them is more cost effective. We investigated the age and cost issues of these tests in screening for LTBI among health-care workers. One hundred and forty new employees during 2008-2011 in our hospital were screened using the QFT-GIT test, and 140 new employees during 2011-2014 were screened with the T-SPOT test for LTBI. The results of both tests were classified as positive, undetermined (retesting required), or negative. There were six positive results (4.29%), eight undetermined results (5.71%), and 126 negative results (90.0%) with the QFT-GIT test. As for the T-SPOT test, there were eight positive results (5.71%), three undetermined results (2.14%), and 129 negative results (92.1%). Fourteen LTBI employees (6 in QFT-GIT and 8 in T-SPOT) were detected statistically equally using the two methods (P = 0.79). The total costs, including those incurred for retesting, were $7,711.86 (US dollar) and $6,525.42 for the QFT-GIT and T-SPOT tests (cost of one test is $55.08 for QFT-GIT and $46.61 for T-SPOT), respectively. T-SPOT is one of the options for screening for LTBI partly owing to the viewpoint of cost-effectiveness. Further prospective studies need to be considered for a definitive conclusion.

  4. Analysis of Baseline Computerized Neurocognitive Testing Results among 5-11-Year-Old Male and Female Children Playing Sports in Recreational Leagues in Florida.

    PubMed

    Liller, Karen D; Morris, Barbara; Fillion, Jessica; Yang, Yingwei; Bubu, Omonigho M

    2017-09-07

    There is a paucity of data related to sports injuries, concussions, and computerized neurocognitive testing (CNT) among very young athletes playing sports in recreational settings. The purpose of this study was to report baseline CNT results among male and female children, ages 5-11, playing sports in Hillsborough County, Florida using ImPACT Pediatric, which is specifically designed for this population. Data were collected from 2016 to 2017. The results show that 657 baseline tests were conducted and t-tests and linear regression were used to assess mean significant differences in composite scores with sex and age. Results showed that females scored better on visual memory and in general as age increased, baseline scores improved. The results can be used to build further studies on the use of CNT in recreational settings and their role in concussion treatment, management, and interventions.

  5. A Spreadsheet Tool for Learning the Multiple Regression F-Test, T-Tests, and Multicollinearity

    ERIC Educational Resources Information Center

    Martin, David

    2008-01-01

    This note presents a spreadsheet tool that allows teachers the opportunity to guide students towards answering on their own questions related to the multiple regression F-test, the t-tests, and multicollinearity. The note demonstrates approaches for using the spreadsheet that might be appropriate for three different levels of statistics classes,…

  6. Experimental parametric studies of transonic T-tail flutter. [wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Sandford, M. C.

    1975-01-01

    Wind-tunnel tests of the T-tail of a wide-body jet airplane were made at Mach numbers up to 1.02. The model consisted of a 1/13-size scaled version of the T-tail, fuselage, and inboard wing of the airplane. Two interchangeable T-tails were tested, one with design stiffness for flutter-clearance studies and one with reduced stiffness for flutter-trend studies. Transonic antisymmetric-flutter boundaries were determined for the models with variations in: (1) fin-spar stiffness, (2) stabilizer dihedral angle (-5 deg and 0 deg), (3) wing and forward-fuselage shape, and (4) nose shape of the fin-stabilizer juncture. A transonic symmetric-flutter boundary and flutter trends were established for variations in stabilizer pitch stiffness. Photographs of the test configurations are shown.

  7. Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2004-01-01

    The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.

  8. Use of a Chagas Urine Nanoparticle Test (Chunap) to Correlate with Parasitemia Levels in T. cruzi/HIV Co-infected Patients.

    PubMed

    Castro-Sesquen, Yagahira E; Gilman, Robert H; Mejia, Carolina; Clark, Daniel E; Choi, Jeong; Reimer-McAtee, Melissa J; Castro, Rosario; Valencia-Ayala, Edward; Flores, Jorge; Bowman, Natalie; Castillo-Neyra, Ricardo; Torrico, Faustino; Liotta, Lance; Bern, Caryn; Luchini, Alessandra

    2016-02-01

    Early diagnosis of reactivated Chagas disease in HIV patients could be lifesaving. In Latin America, the diagnosis is made by microscopical detection of the T. cruzi parasite in the blood; a diagnostic test that lacks sensitivity. This study evaluates if levels of T. cruzi antigens in urine, determined by Chunap (Chagas urine nanoparticle test), are correlated with parasitemia levels in T. cruzi/HIV co-infected patients. T. cruzi antigens in urine of HIV patients (N = 55: 31 T. cruzi infected and 24 T. cruzi serology negative) were concentrated using hydrogel particles and quantified by Western Blot and a calibration curve. Reactivation of Chagas disease was defined by the observation of parasites in blood by microscopy. Parasitemia levels in patients with serology positive for Chagas disease were classified as follows: High parasitemia or reactivation of Chagas disease (detectable parasitemia by microscopy), moderate parasitemia (undetectable by microscopy but detectable by qPCR), and negative parasitemia (undetectable by microscopy and qPCR). The percentage of positive results detected by Chunap was: 100% (7/7) in cases of reactivation, 91.7% (11/12) in cases of moderate parasitemia, and 41.7% (5/12) in cases of negative parasitemia. Chunap specificity was found to be 91.7%. Linear regression analysis demonstrated a direct relationship between parasitemia levels and urine T. cruzi antigen concentrations (p<0.001). A cut-off of > 105 pg was chosen to determine patients with reactivation of Chagas disease (7/7). Antigenuria levels were 36.08 times (95% CI: 7.28 to 64.88) higher in patients with CD4+ lymphocyte counts below 200/mL (p = 0.016). No significant differences were found in HIV loads and CD8+ lymphocyte counts. Chunap shows potential for early detection of Chagas reactivation. With appropriate adaptation, this diagnostic test can be used to monitor Chagas disease status in T. cruzi/HIV co-infected patients.

  9. Driving CAR T-cells forward.

    PubMed

    Jackson, Hollie J; Rafiq, Sarwish; Brentjens, Renier J

    2016-06-01

    The engineered expression of chimeric antigen receptors (CARs) on the surface of T cells enables the redirection of T-cell specificity. Early clinical trials using CAR T cells for the treatment of patients with cancer showed modest results, but the impressive outcomes of several trials of CD19-targeted CAR T cells in the treatment of patients with B-cell malignancies have generated an increased enthusiasm for this approach. Important lessons have been derived from clinical trials of CD19-specific CAR T cells, and ongoing clinical trials are testing CAR designs directed at novel targets involved in haematological and solid malignancies. In this Review, we discuss these trials and present strategies that can increase the antitumour efficacy and safety of CAR T-cell therapy. Given the fast-moving nature of this field, we only discuss studies with direct translational application currently or soon-to-be tested in the clinical setting.

  10. Blister Test for Measurements of Adhesion and Adhesion Degradation of Organic Polymers on AA2024-T3

    NASA Astrophysics Data System (ADS)

    Rincon Troconis, Brendy Carolina

    cleaning/desmutting and conversion coating (CC) on the adhesion strength of acetoacetate to AA2024-T3 and the effects of improper water rinse temperature after cleaner were assessed using the BT. The results showed that pretreatments improve the adhesion strength of acetoacetate primer on AA2024-T3, but the comparative behavior depends on the specific treatment. Process control is of paramount importance for the performance of acetoacetate coated systems applied on AA2024-T3. The lack of thermal activity in the water rinse after cleaning step produces deleterious effects on the adhesion and blistering resistance of CC. Finally, a test sample incorporating a coated and scribed Al alloy panel and uncoated through-hole fasteners (Ti, SS316, AA2024-T3) was designed to provide accelerated response during atmospheric corrosion testing in the field (long-term beach exposure) or in laboratory chambers (ASTM B117). The results after only three weeks of exposure to ASTM B117 correlated well with long-term beach exposure, allowing rapid ranking of different coating systems. Of the fastener materials studied, visual observation and volume lost determination indicated that the worst attack occurred near SS316 fasteners its effect was explained by Scanning Kelvin Probe measurements and the available cathodic current measured in chloride solution.

  11. Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

    NASA Technical Reports Server (NTRS)

    Johnson, Wesley L.

    2011-01-01

    Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

  12. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  13. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  14. Conductor and joint test results of JT-60SA CS and EF coils using the NIFS test facility

    NASA Astrophysics Data System (ADS)

    Obana, Tetsuhiro; Takahata, Kazuya; Hamaguchi, Shinji; Kizu, Kaname; Murakami, Haruyuki; Chikaraishi, Hirotaka; Noguchi, Hiroki; Kobuchi, Takashi; Moriuchi, Sadatomo; Imagawa, Shinsaku; Mito, Toshiyuki; Tsuchiya, Katsuhiko; Natsume, Kyohei; Yoshida, Kiyoshi; Nomoto, Kazuhiro; Kim, Tae-hyun

    2016-01-01

    In 2007, JAEA and NIFS launched the test project to evaluate the performance of cable-in-conduit (CIC) conductors and conductor joints for the JT-60SA CS and EF coils. In this project, conductor tests for four types of coil conductor and joint tests for seven types of conductor joint have been conducted for the past eight years using the NIFS test facility. As a result, the test project indicated that the CIC conductors and conductor joints fulfill the design requirement for the CS and EF coils. In addition, the NIFS test facility is expected to be utilized as the test facility for the development of a conductor and conductor joint for the purpose of the DEMO nuclear fusion power plant, provided that the required magnetic field strength is within 9 T.

  15. Using the Student's "t"-Test with Extremely Small Sample Sizes

    ERIC Educational Resources Information Center

    de Winter, J. C .F.

    2013-01-01

    Researchers occasionally have to work with an extremely small sample size, defined herein as "N" less than or equal to 5. Some methodologists have cautioned against using the "t"-test when the sample size is extremely small, whereas others have suggested that using the "t"-test is feasible in such a case. The present…

  16. SSME seal test program: Test results for smooth, hole-pattern and helically-grooved stators

    NASA Technical Reports Server (NTRS)

    Childs, Dara W.

    1987-01-01

    All of the listed seals were tested in a liquid Halon test facility at high Reynolds numbers. In addition, a helically-grooved-stator seal was tested in an air seal facility. An analysis of the test results with comparisons to theoretical predictions supports the following conclusions: (1) For small seals, the Hirs' friction-factor model is more restricted than had been thought; (2) For smooth seals, predictions of stiffness and damping improve markedly as the radical clearance is reduced; (3) Friction-factor data for hole-pattern-seal stators frequently deviates from the Hirs model; (4) Predictions of stiffness and damping coefficients for hole-pattern-stator seals is generally reasonable; (5) Tests for the hole-pattern stators at reduced clearances show no clear optimum for hole-pattern seals with respect to either hole-area ratio or hole depth to minimum clearance ratios; (6) Tests of these hole-pattern stators show no significant advantage in net damping over smooth seals; (7) Tests of helically-grooved seal stators in Halon show reasonable agreement between theory and prediction for leakage and direct stiffness but poor agreement for the net damping coefficient.

  17. DarT: The embryo test with the Zebrafish Danio rerio--a general model in ecotoxicology and toxicology.

    PubMed

    Nagel, Roland

    2002-01-01

    The acute fish test is an animal test whose ecotoxicological relevance is worthy of discussion. The primary aim of protection in ecotoxicology is the population and not the individual. Furthermore the concentration of pollutants in the environment is normally not in the lethal range. Therefore the acute fish test covers solely the situation after chemical spills. Nevertheless, acute fish toxicity data still belong to the base set used for the assessment of chemicals. The embryo test with the zebrafish Danio rerio (DarT) is recommended as a substitute for the acute fish test. For validation an international laboratory comparison test was carried out. A summary of the results is presented in this paper. Based on the promising results of testing chemicals and waste water the test design was validated by the DIN-working group "7.6 Fischei-Test". A normed test guideline for testing waste water with fish is available. The test duration is short (48 h) and within the test different toxicological endpoints can be examined. Endpoints from the embryo test are suitable for QSAR-studies. Besides the use in ecotoxicology the introduction as a toxicological model was investigated. Disturbance of pigmentation and effects on the frequency of heart-beat were examined. A further important application is testing of teratogenic chemicals. Based on the results DarT could be a screening test within preclinical studies.

  18. 46 CFR 35.20-10 - Steering gear test-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Steering gear test-T/ALL. 35.20-10 Section 35.20-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-10 Steering gear test—T/ALL. On all tankships making voyages of more than 48 hours' duration, the entire...

  19. 46 CFR 35.20-10 - Steering gear test-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Steering gear test-T/ALL. 35.20-10 Section 35.20-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-10 Steering gear test—T/ALL. On all tankships making voyages of more than 48 hours' duration, the entire...

  20. 3. INTERIOR VIEW, SHOWING JET ENGINE TEST STAND. WrightPatterson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. INTERIOR VIEW, SHOWING JET ENGINE TEST STAND. - Wright-Patterson Air Force Base, Area B, Building 71A, Propulsion Research Laboratory, Seventh Street between D & G Streets, Dayton, Montgomery County, OH

  1. The 3T3 neutral red uptake phototoxicity test: practical experience and implications for phototoxicity testing--the report of an ECVAM-EFPIA workshop.

    PubMed

    Ceridono, Mara; Tellner, Pär; Bauer, Daniel; Barroso, João; Alépée, Nathalie; Corvi, Raffaella; De Smedt, Ann; Fellows, Mick D; Gibbs, Neil K; Heisler, Eckhard; Jacobs, Abigail; Jirova, Dagmar; Jones, David; Kandárová, Helena; Kasper, Peter; Akunda, Jacqueline Kinyamu; Krul, Cyrille; Learn, Douglas; Liebsch, Manfred; Lynch, Anthony M; Muster, Wolfgang; Nakamura, Kazuichi; Nash, J Frank; Pfannenbecker, Uwe; Phillips, Gareth; Robles, Catherine; Rogiers, Vera; Van De Water, Femke; Liminga, Ulla Wändel; Vohr, Hans-Werner; Wattrelos, Olivier; Woods, Julie; Zuang, Valérie; Kreysa, Joachim; Wilcox, Phil

    2012-08-01

    This is the report from the "ECVAM-EFPIA workshop on 3T3 NRU Phototoxicity Test: Practical Experience and Implications for Phototoxicity Testing", jointly organized by ECVAM and EFPIA and held on the 25-27 October 2010 in Somma Lombardo, Italy. The European Centre for the Validation of Alternative Methods (ECVAM) was established in 1991 within the European Commission Joint Research, based on a Communication from the European Commission (1991). The main objective of ECVAM is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine and replace the use of laboratory animals. The European Federation of Pharmaceuticals Industries and Association (EFPIA) represent the pharmaceutical industry operating in Europe. Through its direct membership of 31 national associations and 40 leading pharmaceutical companies, EFPIA is the voice on the EU scene of 2200 companies committed to researching, developing and bringing to patients new medicines that improve health and the quality of life around the world. The workshop, co-chaired by Joachim Kreysa (ECVAM) and Phil Wilcox (GSK, EFPIA) involved thirty-five experts from academia, regulatory authorities and industry, invited to contribute with their experiences in the field of phototoxicology. The main objectives of the workshop were: -to present 'in use' experience of the pharmaceutical industry with the 3T3 Neutral Red Uptake Phototoxicity Test (3T3 NRU-PT), -to discuss why it differs from the results in the original validation exercise, -to discuss technical issues and consider ways to improve the usability of the 3T3 NRU-PT for (non-topical) pharmaceuticals, e.g., by modifying the threshold of chemical light absorption to trigger photo-toxicological testing, and by modifying technical aspects of the assay, or adjusting the criteria used to classify a positive response. During the workshop, the assay methodology was reviewed by comparing the OECD

  2. Driving CAR T-cells forward

    PubMed Central

    Jackson, Hollie J.; Rafiq, Sarwish; Brentjens, Renier J.

    2017-01-01

    The engineered expression of chimeric antigen receptors (CARs) on the surface of T cells enables the redirection of T-cell specificity. Early clinical trials using CAR T cells for the treatment of patients with cancer showed modest results, but the impressive outcomes of several trials of CD19-targeted CAR T cells in the treatment of patients with B-cell malignancies have generated an increased enthusiasm for this approach. Important lessons have been derived from clinical trials of CD19-specific CAR T cells, and ongoing clinical trials are testing CAR designs directed at novel targets involved in haematological and solid malignancies. In this Review, we discuss these trials and present strategies that can increase the antitumour efficacy and safety of CAR T-cell therapy. Given the fast-moving nature of this field, we only discuss studies with direct translational application currently or soon-to-be tested in the clinical setting. PMID:27000958

  3. Theileria parva antigens recognized by CD8+ T cells show varying degrees of diversity in buffalo-derived infected cell lines.

    PubMed

    Sitt, Tatjana; Pelle, Roger; Chepkwony, Maurine; Morrison, W Ivan; Toye, Philip

    2018-05-06

    The extent of sequence diversity among the genes encoding 10 antigens (Tp1-10) known to be recognized by CD8+ T lymphocytes from cattle immune to Theileria parva was analysed. The sequences were derived from parasites in 23 buffalo-derived cell lines, three cattle-derived isolates and one cloned cell line obtained from a buffalo-derived stabilate. The results revealed substantial variation among the antigens through sequence diversity. The greatest nucleotide and amino acid diversity were observed in Tp1, Tp2 and Tp9. Tp5 and Tp7 showed the least amount of allelic diversity, and Tp5, Tp6 and Tp7 had the lowest levels of protein diversity. Tp6 was the most conserved protein; only a single non-synonymous substitution was found in all obtained sequences. The ratio of non-synonymous: synonymous substitutions varied from 0.84 (Tp1) to 0.04 (Tp6). Apart from Tp2 and Tp9, we observed no variation in the other defined CD8+ T cell epitopes (Tp4, 5, 7 and 8), indicating that epitope variation is not a universal feature of T. parva antigens. In addition to providing markers that can be used to examine the diversity in T. parva populations, the results highlight the potential for using conserved antigens to develop vaccines that provide broad protection against T. parva.

  4. Outlier removal, sum scores, and the inflation of the Type I error rate in independent samples t tests: the power of alternatives and recommendations.

    PubMed

    Bakker, Marjan; Wicherts, Jelte M

    2014-09-01

    In psychology, outliers are often excluded before running an independent samples t test, and data are often nonnormal because of the use of sum scores based on tests and questionnaires. This article concerns the handling of outliers in the context of independent samples t tests applied to nonnormal sum scores. After reviewing common practice, we present results of simulations of artificial and actual psychological data, which show that the removal of outliers based on commonly used Z value thresholds severely increases the Type I error rate. We found Type I error rates of above 20% after removing outliers with a threshold value of Z = 2 in a short and difficult test. Inflations of Type I error rates are particularly severe when researchers are given the freedom to alter threshold values of Z after having seen the effects thereof on outcomes. We recommend the use of nonparametric Mann-Whitney-Wilcoxon tests or robust Yuen-Welch tests without removing outliers. These alternatives to independent samples t tests are found to have nominal Type I error rates with a minimal loss of power when no outliers are present in the data and to have nominal Type I error rates and good power when outliers are present. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  5. 5. INTERIOR VIEW, SHOWING TEST MACHINERY IN FOREGROUND AND CONTROL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INTERIOR VIEW, SHOWING TEST MACHINERY IN FOREGROUND AND CONTROL ROOM IN BACKGROUND. - Wright-Patterson Air Force Base, Area B, Building 20, Propeller Laboratory, Northwest corner of Seventh & E Streets, Dayton, Montgomery County, OH

  6. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    PubMed

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Creep Tests and Modeling Based on Continuum Damage Mechanics for T91 and T92 Steels

    NASA Astrophysics Data System (ADS)

    Pan, J. P.; Tu, S. H.; Zhu, X. W.; Tan, L. J.; Hu, B.; Wang, Q.

    2017-12-01

    9-11%Cr ferritic steels play an important role in high-temperature and high-pressure boilers of advanced power plants. In this paper, a continuum damage mechanics (CDM)-based creep model was proposed to study the creep behavior of T91 and T92 steels at high temperatures. Long-time creep tests were performed for both steels under different conditions. The creep rupture data and creep curves obtained from creep tests were captured well by theoretical calculation based on the CDM model over a long creep time. It is shown that the developed model is able to predict creep data for the two ferritic steels accurately up to tens of thousands of hours.

  8. Ares I Scale Model Acoustic Test Liftoff Acoustic Results and Comparisons

    NASA Technical Reports Server (NTRS)

    Counter, Doug; Houston, Janice

    2011-01-01

    Conclusions: Ares I-X flight data validated the ASMAT LOA results. Ares I Liftoff acoustic environments were verified with scale model test results. Results showed that data book environments were under-conservative for Frustum (Zone 5). Recommendations: Data book environments can be updated with scale model test and flight data. Subscale acoustic model testing useful for future vehicle environment assessments.

  9. [Interpretation of false positive results of biochemical prenatal tests].

    PubMed

    Sieroszewski, Piotr; Słowakiewicz, Katarzyna; Perenc, Małgorzata

    2010-03-01

    Modern, non-invasive prenatal diagnostics based on biochemical and ultrasonographic markers of fetal defects allows us to calculate the risk of fetal chromosomal aneuploidies with high sensitivity and specificity An introduction of biochemical, non-invasive prenatal tests turned out to result in frequent false positive results of these tests in cases when invasive diagnostics does not confirm fetal defects. However prospective analysis of these cases showed numerous complications in the third trimester of the pregnancies.

  10. Cholesterol testing and results

    MedlinePlus

    ... profile results; Hyperlipidemia-results; Lipid disorder test results; Heart disease - cholesterol results ... at an earlier age if you have: Diabetes Heart disease Stroke High blood pressure A strong family history ...

  11. 46 CFR 35.20-10 - Steering gear test-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Steering gear test-T/ALL. 35.20-10 Section 35.20-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-10 Steering gear test—T/ALL. On all tankships making voyages of more than 48 hours' duration, the entire steering gear, the whistle, the means of...

  12. Sex-based differences in plasma chemistry and cardiac marker test results in Siamese fighting fowl.

    PubMed

    Sribhen, Choosri; Choothesa, Apassara; Songserm, Thaveesak; Issariyodom, Supaporn; Sribhen, Kosit

    2006-09-01

    Variations in the results of plasma chemistry analysis as a function of sex have rarely been demonstrated in avian species. The aim of the present study was to investigate sex-related differences in values for routine biochemical variables, including conventional muscle enzymes, and novel cardiac markers in female and male Siamese fighting fowl. Plasma chemistry analytes and cardiac marker proteins (creatine kinase-MB and cardiac troponin T) were measured in 70 Siamese fighting fowl using automated chemistry and immunoassay analyzers. Data were compared by 2-tailed t tests between sexes, and Spearman rank correlation between conventional and novel cardiac markers. Male fowl had significantly higher uric acid concentration and gamma-glutamyltransferase activity; whereas, female fowl had significantly higher total cholesterol, triglycerides, and calcium concentrations, and alkaline phosphatase activity. As compared with female fowl, the fighting cocks also had significantly higher plasma concentrations of creatine kinase-MB and cardiac troponin T. Significant correlations between cardiac troponin T, but not creatine kinase-MB, and the activities of conventional muscle enzymes (creatine kinase, aspartate aminotransferase and lactate dehydrogenase) were observed in male but not in female fowl. These results indicate that sex-specific differences exist for several biochemical parameters and cardiac marker proteins in fighting fowl, and that such differences should be considered in interpreting laboratory test results.

  13. Analysis of CFRP Joints by Means of T-Pull Mechanical Test and Ultrasonic Defects Detection.

    PubMed

    Casavola, Caterina; Palano, Fania; De Cillis, Francesco; Tati, Angelo; Terzi, Roberto; Luprano, Vincenza

    2018-04-18

    Defects detection within a composite component, with the aim of understanding and predicting its mechanical behavior, is of great importance in the aeronautical field because the irregularities of the composite material could compromise functionality. The aim of this paper is to detect defects by means of non-destructive testing (NDT) on T-pull samples made by carbon fiber reinforced polymers (CFRP) and to evaluate their effect on the mechanical response of the material. Samples, obtained from an industrial stringer having an inclined web and realized with a polymeric filler between cap and web, were subjected to ultrasonic monitoring and then to T-pull mechanical tests. All samples were tested with the same load mode and the same test configuration. An experimental set-up consisting of a semiautomatic C-scan ultrasonic mapping system with a phased array probe was designed and developed, optimizing control parameters and implementing image processing software. The present work is carried out on real composites parts that are characterized by having their intrinsic defectiveness, as opposed to the previous similar results in the literature mainly obtained on composite parts with artificially produced defects. In fact, although samples under study were realized free from defects, ultrasonic mapping found defectiveness inside the material. Moreover, the ultrasonic inspection could be useful in detecting both the location and size of defects. Experimental data were critically analyzed and qualitatively correlated with results of T-pull mechanical tests in order to better understand and explain mechanical behavior in terms of fracture mode.

  14. Analysis of CFRP Joints by Means of T-Pull Mechanical Test and Ultrasonic Defects Detection

    PubMed Central

    Casavola, Caterina; Palano, Fania; De Cillis, Francesco; Tati, Angelo; Terzi, Roberto; Luprano, Vincenza

    2018-01-01

    Defects detection within a composite component, with the aim of understanding and predicting its mechanical behavior, is of great importance in the aeronautical field because the irregularities of the composite material could compromise functionality. The aim of this paper is to detect defects by means of non-destructive testing (NDT) on T-pull samples made by carbon fiber reinforced polymers (CFRP) and to evaluate their effect on the mechanical response of the material. Samples, obtained from an industrial stringer having an inclined web and realized with a polymeric filler between cap and web, were subjected to ultrasonic monitoring and then to T-pull mechanical tests. All samples were tested with the same load mode and the same test configuration. An experimental set-up consisting of a semiautomatic C-scan ultrasonic mapping system with a phased array probe was designed and developed, optimizing control parameters and implementing image processing software. The present work is carried out on real composites parts that are characterized by having their intrinsic defectiveness, as opposed to the previous similar results in the literature mainly obtained on composite parts with artificially produced defects. In fact, although samples under study were realized free from defects, ultrasonic mapping found defectiveness inside the material. Moreover, the ultrasonic inspection could be useful in detecting both the location and size of defects. Experimental data were critically analyzed and qualitatively correlated with results of T-pull mechanical tests in order to better understand and explain mechanical behavior in terms of fracture mode. PMID:29669992

  15. Advanced Guidance and Control Methods for Reusable Launch Vehicles: Test Results

    NASA Technical Reports Server (NTRS)

    Hanson, John M.; Jones, Robert E.; Krupp, Don R.; Fogle, Frank R. (Technical Monitor)

    2002-01-01

    There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety/reliability and reducing the cost. In this paper, we examine some of these methods and compare the results. We briefly introduce the various methods under test, list the test cases used to demonstrate that the desired results are achieved, show an automated test scoring method that greatly reduces the evaluation effort required, and display results of the tests. Results are shown for the algorithms that have entered testing so far.

  16. 4. Exterior view of Components Test Laboratory (T27), looking northeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Exterior view of Components Test Laboratory (T-27), looking northeast. The building wing on the left houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault, and that on the right houses Test Cell 10 (environmental). - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  17. 5. Exterior view of Components Test Laboratory (T27), looking northwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Exterior view of Components Test Laboratory (T-27), looking northwest. The building wing on the left houses Test Cell 10 (environmental), and that on the right houses Test Cell 9 (fuel) and the fuel storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  19. T-Cap Pull-Off and Bending Behavior for Stitched Structure

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Leone, Frank A., Jr.

    2016-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is a structural concept that was developed by The Boeing Company to address the complex structural design aspects associated with a pressurized hybrid wing body aircraft configuration. An important design feature required for assembly is the integrally stitched T-cap, which provides connectivity of the corner (orthogonal) joint between adjacent panels. A series of tests were conducted on T-cap test articles, with and without a rod stiffener penetrating the T-cap web, under tension (pull-off) and bending loads. Three designs were tested, including the baseline design used in largescale test articles. The baseline had only the manufacturing stitch row adjacent to the fillet at the base of the T-cap web. Two new designs added stitching rows to the T-cap web at either 0.5- or 1.0-inch spacing along the height of the web. Testing was conducted at NASA Langley Research Center to determine the behavior of the T-cap region resulting from the applied loading. Results show that stitching arrests the initial delamination failures so that the maximum strength capability exceeds the load at which the initial delaminations develop. However, it was seen that the added web stitching had very little effect on the initial delamination failure load, but actually decreased the initial delamination failure load for tension loading of test articles without a stiffener passing through the web. Additionally, the added web stitching only increased the maximum load capability by between 1% and 12.5%. The presence of the stiffener, however, did increase the initial and maximum loads for both tension and bending loading as compared to the stringerless baseline design. Based on the results of the few samples tested, the additional stitching in the T-cap web showed little advantage over the baseline design in terms of structural failure at the T-cap web/skin junction for the current test articles.

  20. A hypoallergenic variant of the major birch pollen allergen shows distinct characteristics in antigen processing and T-cell activation.

    PubMed

    Kitzmüller, C; Wallner, M; Deifl, S; Mutschlechner, S; Walterskirchen, C; Zlabinger, G J; Ferreira, F; Bohle, B

    2012-11-01

    BM4 is a novel genetically engineered variant of the major birch pollen allergen Bet v 1 that lacks the typical Bet v 1-like fold and displays negligible IgE-binding but strong T cell-activating capacity. The aim of this study was to elucidate possible differences between BM4 and Bet v 1 in internalization, antigen processing, and presentation. Proliferative responses to BM4 and Bet v 1 of peripheral blood mononuclear cells and Bet v 1-specific T-cell clones were compared. Fluorescently labeled BM4 and Bet v 1 were used to study surface binding, endocytosis, and intracellular degradation by monocyte-derived DC (mdDC). Both proteins were digested by endolysosomal extracts of mdDC. BM4- and Bet v 1-pulsed mdDC were employed to assess the kinetics of activation of Bet v 1-specific T-cell clones and the polarization of naïve T cells. BM4 displayed a significantly stronger T cell-activating capacity than Bet v 1. Furthermore, BM4 showed increased surface binding and internalization as well as faster endolysosomal degradation compared with Bet v 1. BM4-pulsed mdDC induced enhanced proliferative responses at earlier time-points in Bet v 1-specific T-cell clones and promoted less IL-5 production in T cells than Bet v 1-pulsed mdDC. The loss of the Bet v 1-fold changes the protein's interaction with the human immune system at the level of antigen-presenting cells resulting in altered T-cell responses. By combining low IgE-binding with strong and modulating T cell-activating capacity, BM4 represents a highly interesting candidate for specific immunotherapy of birch pollen allergy. © 2012 John Wiley & Sons A/S.

  1. Use of a Chagas Urine Nanoparticle Test (Chunap) to Correlate with Parasitemia Levels in T. cruzi/HIV Co-infected Patients

    PubMed Central

    Castro-Sesquen, Yagahira E.; Gilman, Robert H.; Mejia, Carolina; Clark, Daniel E.; Choi, Jeong; Reimer-McAtee, Melissa J.; Castro, Rosario; Valencia-Ayala, Edward; Flores, Jorge; Bowman, Natalie; Castillo-Neyra, Ricardo; Torrico, Faustino; Liotta, Lance; Bern, Caryn; Luchini, Alessandra

    2016-01-01

    Background Early diagnosis of reactivated Chagas disease in HIV patients could be lifesaving. In Latin America, the diagnosis is made by microscopical detection of the T. cruzi parasite in the blood; a diagnostic test that lacks sensitivity. This study evaluates if levels of T. cruzi antigens in urine, determined by Chunap (Chagas urine nanoparticle test), are correlated with parasitemia levels in T. cruzi/HIV co-infected patients. Methodology/Principal Findings T. cruzi antigens in urine of HIV patients (N = 55: 31 T. cruzi infected and 24 T. cruzi serology negative) were concentrated using hydrogel particles and quantified by Western Blot and a calibration curve. Reactivation of Chagas disease was defined by the observation of parasites in blood by microscopy. Parasitemia levels in patients with serology positive for Chagas disease were classified as follows: High parasitemia or reactivation of Chagas disease (detectable parasitemia by microscopy), moderate parasitemia (undetectable by microscopy but detectable by qPCR), and negative parasitemia (undetectable by microscopy and qPCR). The percentage of positive results detected by Chunap was: 100% (7/7) in cases of reactivation, 91.7% (11/12) in cases of moderate parasitemia, and 41.7% (5/12) in cases of negative parasitemia. Chunap specificity was found to be 91.7%. Linear regression analysis demonstrated a direct relationship between parasitemia levels and urine T. cruzi antigen concentrations (p<0.001). A cut-off of > 105 pg was chosen to determine patients with reactivation of Chagas disease (7/7). Antigenuria levels were 36.08 times (95% CI: 7.28 to 64.88) higher in patients with CD4+ lymphocyte counts below 200/mL (p = 0.016). No significant differences were found in HIV loads and CD8+ lymphocyte counts. Conclusion Chunap shows potential for early detection of Chagas reactivation. With appropriate adaptation, this diagnostic test can be used to monitor Chagas disease status in T. cruzi/HIV co

  2. The "Don't Know" Option in Progress Testing

    ERIC Educational Resources Information Center

    Ravesloot, C. J.; Van der Schaaf, M. F.; Muijtjens, A. M. M.; Haaring, C.; Kruitwagen, C. L. J. J.; Beek, F. J. A.; Bakker, J.; Van Schaik, J.P.J.; Ten Cate, Th. J.

    2015-01-01

    Formula scoring (FS) is the use of a don't know option (DKO) with subtraction of points for wrong answers. Its effect on construct validity and reliability of progress test scores, is subject of discussion. Choosing a DKO may not only be affected by knowledge level, but also by risk taking tendency, and may thus introduce construct-irrelevant…

  3. Experimental Chagas disease in Balb/c mice previously vaccinated with T. rangeli. II. The innate immune response shows immunological memory: reality or fiction?

    PubMed

    Basso, B; Marini, V

    2015-03-01

    Trypanosoma cruzi is a real challenge to the host's immune system, because it requires strong humoral and cellular immune response to remove circulating trypomastigote forms, and to prevent the replication of amastigote forms in tissues, involving many regulator and effector components. This protozoan is responsible for Chagas disease, a major public health problem in Latinamerica. We have developed a model of vaccination with Trypanosoma rangeli, a parasite closely related to T. cruzi, but nonpathogenic to humans, which reduces the infectiousness in three different species of animals, mice, dogs and guinea pigs, against challenge with T. cruzi. In a previous work, we demonstrated that mice vaccinated with T. rangeli showed important soluble mediators that stimulate phagocytic activity versus only infected groups. The aim of this work was to study the innate immune response in mice vaccinated or not with T. rangeli. Different population cells and some soluble mediators (cytokines) in peritoneal fluid and plasma in mice vaccinated-infected and only infected with T. cruzi were studied. In the first hours of challenge vaccinated mice showed an increase of macrophages, NK, granulocytes, and regulation of IL6, IFNγ, TNFα and IL10, with an increase of IL12, with respect to only infected mice. Furthermore an increase was observed of Li T, Li B responsible for adaptative response. Finally the findings showed that the innate immune response plays an important role in vaccinated mice for the early elimination of the parasites, complementary with the adaptative immune response, suggesting that vaccination with T. rangeli modulates the innate response, which develops some kind of immunological memory, recognizing shared antigens with T. cruzi. These results could contribute to the knowledge of new mechanisms which would have an important role in the immune response to Chagas disease. Copyright © 2014 Elsevier GmbH. All rights reserved.

  4. LPT. Shield test facility (TAN645 and 646). Elevations show three ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-645 and -646). Elevations show three types of siding: Asbestos cement, pumice block, concrete. Ralph M. Parsons 1229-17 ANP/GE-6-6445-A-3. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-06445/0646-00-693-107349 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  5. Evaluation of Precast Panels for Airfield Pavement Repair. Phase 2: Results of Accelerated Pavement Testing

    DTIC Science & Technology

    2013-09-01

    ER D C/ G SL T R -1 3 -2 4 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement Testing...default. ERDC/GSL TR-13-24 September 2013 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement ... pavement testing using a C-17 load cart to evaluate the performance of a precast portland cement concrete (PCC) pavement repair system. The system

  6. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  7. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  8. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  9. The determination of the orbit of the Japanese satellite Ajisai and the GEM-T1 and GEM-T2 gravity field models

    NASA Technical Reports Server (NTRS)

    Sanchez, Braulio V.

    1990-01-01

    The Japanese Experimental Geodetic Satellite Ajisai was launched on August 12, 1986. In response to the TOPEX-POSEIDON mission requirements, the GSFC Space Geodesy Branch and its associates are producing improved models of the Earth's gravitational field. With the launch of Ajisai, precise laser data is now available which can be used to test many current gravity models. The testing of the various gravity field models show improvements of more than 70 percent in the orbital fits when using GEM-T1 and GEM-T2 relative to results obtained with the earlier GEM-10B model. The GEM-T2 orbital fits are at the 13-cm level (RMS). The results of the tests with the various versions of the GEM-T1 model indicate that the addition of satellite altimetry and surface gravity anomalies as additional data types should improve future gravity field models.

  10. Model tests for the efficacy of disinfectants on surfaces. IV. Communication: dependence of test results on the amount of contamination and the kind of active substance.

    PubMed

    Peters, J; Spicher, G

    1998-12-01

    In the assessment of efficacy of surface disinfectants, many influencing factors have to be taken into account. One essential item is whether the surface to be disinfected is clean or soiled. Among the feasible soilings, the blood is of particular consequences because it ads impediments to many disinfecting agents. This paper shows to what extent the impairment of the efficacy of typical active agents depends on the blood burden of the surfaces. Therefore, test surfaces (varnished plywood) were contaminated with 0.01 to 0.08 ml of coagulating blood per test area (3 cm2). The blood contained cells of Staphylococcus aureus as test germs. The disinfection was effected by immersing the test objects in the disinfecting solution for 5 seconds and mingling the adhering disinfecting solution (about 0.02 ml) with the coagulated blood on the test surface with a glass spatula for about 20 seconds. Subsequently, the test objects remained in a horizontal position at room conditions for 4 hours and then the numbers of surviving test germs were determined. The graphical representation of the results shows that the efficacy curves of formaldehyde and phenol lie very closely together, i.e. their effect is hardly impaired by the different blood burdens of the test areas. The efficacy curves of glutaraldehyde, peracetic acid, chloramine T, and quaternary ammonium compounds lie very far apart from each other. To achieve the same microbicidal effect (log N/N0 = -5) when the contaminating amount is raised from 10 microliters/3 cm2 to 80 microliters/3 cm2, the concentration of chloramine T has to be raised by a factor of 5.4, peracetic acid by a factor of 9, glutaraldehyde by a factor of 24, quaternary ammonium compound even by a factor of 67. Ethanol and sodium hypochlorite showed a divergent behaviour. For ethanol, the efficacy diminution produced by increasing the contamination amount by a factor of 4 can be compensated by raising the concentration from 50% to about 70%. But again and

  11. 29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  12. 7. Exterior view of Components Test Laboratory (T27), looking south. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Exterior view of Components Test Laboratory (T-27), looking south. The wing in the immediate foreground houses the equipment room. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  13. Effectiveness comparison of partially executed t-way test suite based generated by existing strategies

    NASA Astrophysics Data System (ADS)

    Othman, Rozmie R.; Ahmad, Mohd Zamri Zahir; Ali, Mohd Shaiful Aziz Rashid; Zakaria, Hasneeza Liza; Rahman, Md. Mostafijur

    2015-05-01

    Consuming 40 to 50 percent of software development cost, software testing is one of the most resource consuming activities in software development lifecycle. To ensure an acceptable level of quality and reliability of a typical software product, it is desirable to test every possible combination of input data under various configurations. Due to combinatorial explosion problem, considering all exhaustive testing is practically impossible. Resource constraints, costing factors as well as strict time-to-market deadlines are amongst the main factors that inhibit such consideration. Earlier work suggests that sampling strategy (i.e. based on t-way parameter interaction or called as t-way testing) can be effective to reduce number of test cases without effecting the fault detection capability. However, for a very large system, even t-way strategy will produce a large test suite that need to be executed. In the end, only part of the planned test suite can be executed in order to meet the aforementioned constraints. Here, there is a need for test engineers to measure the effectiveness of partially executed test suite in order for them to assess the risk they have to take. Motivated by the abovementioned problem, this paper presents the effectiveness comparison of partially executed t-way test suite generated by existing strategies using tuples coverage method. Here, test engineers can predict the effectiveness of the testing process if only part of the original test cases is executed.

  14. Boston Community Information System 1986 Experimental Test Results.

    DTIC Science & Technology

    1987-08-01

    self -selected participants have a strong technical orientation and high educational achievement. In addition, five visually impaired people use the...group. The experimental test of the system was performed on a self -selected population of computer literate volunteers. In order to simplify the test...for fat respose .’ - 1041 OI haven’t used it yet.’ - 1046 ’No modem yet. New version installed 11/2/86.0 - 1047 ’Not yet tried. Wil do so moon.’ - 1061

  15. Update on results of SPRE testing at NASA Lewis

    NASA Technical Reports Server (NTRS)

    Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.

    1991-01-01

    The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigate the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The effects of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance test results with HFAST code predictions show good agreement for PV power but poor agreement for PV efficiency. Correlations are presented relating the piston mid-stroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

  16. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  17. High Stability Engine Control (HISTEC) Flight Test Results

    NASA Technical Reports Server (NTRS)

    Southwick, Robert D.; Gallops, George W.; Kerr, Laura J.; Kielb, Robert P.; Welsh, Mark G.; DeLaat, John C.; Orme, John S.

    1998-01-01

    The High Stability Engine Control (HISTEC) Program, managed and funded by the NASA Lewis Research Center, is a cooperative effort between NASA and Pratt & Whitney (P&W). The program objective is to develop and flight demonstrate an advanced high stability integrated engine control system that uses real-time, measurement-based estimation of inlet pressure distortion to enhance engine stability. Flight testing was performed using the NASA Advanced Controls Technologies for Integrated Vehicles (ACTIVE) F-15 aircraft at the NASA Dryden Flight Research Center. The flight test configuration, details of the research objectives, and the flight test matrix to achieve those objectives are presented. Flight test results are discussed that show the design approach can accurately estimate distortion and perform real-time control actions for engine accommodation.

  18. 2. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  19. 3. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room, and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  20. ASTAR Flight Test: Overview and Spacing Results

    NASA Technical Reports Server (NTRS)

    Roper, Roy D.; Koch, Michael R.

    2016-01-01

    The purpose of the NASA Langley Airborne Spacing for Terminal Arrival Routes (ASTAR) research aboard the Boeing ecoDemonstrator aircraft was to demonstrate the use of NASA's ASTAR algorithm using contemporary tools of the Federal Aviation Administration's Next Generation Air Transportation System (NEXTGEN). EcoDemonstrator is a Boeing test program which utilizes advanced experimental equipment to accelerate the science of aerospace and environmentally friendly technologies. The ASTAR Flight Test provided a proof-of-concept flight demonstration that exercised an algorithmic-based application in an actual aircraft. The test aircraft conducted Interval Management operations to provide time-based spacing off a target aircraft in non-simulator wind conditions. Work was conducted as a joint effort between NASA and Boeing to integrate ASTAR in a Boeing supplied B787 test aircraft while using a T-38 aircraft as the target. This demonstration was also used to identify operational risks to future flight trials for the NASA Air Traffic Management Technology Demonstration expected in 2017.

  1. Mechanical Properties of Multi-Year Sea Ice. Phase 2. Test Results

    DTIC Science & Technology

    1985-10-01

    test3specimenstat spcd n tdVf-n plidsrs’ -20°Ct applied stess-iez mp era- aurs 10 4 1M -.......- . ..L . .. .. * t o’ -04% Stes lb/l t \\\\r "".% \\ . ~~~~~~~Figure

  2. LPT. Shield test facility (TAN645 and 646). Sections show relationships ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-645 and -646). Sections show relationships among control rooms, coupling station, counting rooms, pools, equipment rooms, data room and other areas. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-4. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107350 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. Peripheral T cell lymphomas: an immunological study of seven unusual cases.

    PubMed

    Raziuddin, S; Latif, A B; Arif, S; Ahad, A; Zaidi, A Z

    1988-05-01

    A multiparameter study of malignant lymph node cells and peripheral blood lymphocytes of seven patients with peripheral T cell lymphoma is presented. The results of monoclonal marker studies showed three cases of helper-suppressor T cell lymphoma (OKT4+, OKT8+), one case of suppressor T cell lymphoma (OKT8+), and three cases of helper T cell lymphoma (OKT4+). Immunophenotypic heterogeneity of neoplastic T cells with expression of pan-T antigens, OKT3+, and OKT11+ (erythrocyte rosetting+) was observed in most patients. Six of the seven cases tested showed Ia and DR antigens. No relationship was detected between patterns of reactivity with T cell reagents and histological types. When tested, the in-vitro malignant T cells of five patients proliferated in response to concanavalin A (Con A), but had poor response to phytohaemagglutinin. The interleukin 2 receptors showed maximum expression on Con A-activated T cells of five patients, and phytohaemagglutinin-activated T cells of one patient. The neoplastic T cells (OKT4+, OKT8+) of one patient studied had suppressor activity for IgG and IgA, and helper activity for IgM synthesis on pokeweed mitogen-induced normal B cell differentiations.

  4. T-cell receptor transfer into human T cells with ecotropic retroviral vectors.

    PubMed

    Koste, L; Beissert, T; Hoff, H; Pretsch, L; Türeci, Ö; Sahin, U

    2014-05-01

    Adoptive T-cell transfer for cancer immunotherapy requires genetic modification of T cells with recombinant T-cell receptors (TCRs). Amphotropic retroviral vectors (RVs) used for TCR transduction for this purpose are considered safe in principle. Despite this, TCR-coding and packaging vectors could theoretically recombine to produce replication competent vectors (RCVs), and transduced T-cell preparations must be proven free of RCV. To eliminate the need for RCV testing, we transduced human T cells with ecotropic RVs so potential RCV would be non-infectious for human cells. We show that transfection of synthetic messenger RNA encoding murine cationic amino-acid transporter 1 (mCAT-1), the receptor for murine retroviruses, enables efficient transient ecotropic transduction of human T cells. mCAT-1-dependent transduction was more efficient than amphotropic transduction performed in parallel, and preferentially targeted naive T cells. Moreover, we demonstrate that ecotropic TCR transduction results in antigen-specific restimulation of primary human T cells. Thus, ecotropic RVs represent a versatile, safe and potent tool to prepare T cells for the adoptive transfer.

  5. Role of Admission Troponin-T and Serial Troponin-T Testing in Predicting Outcomes in Severe Sepsis and Septic Shock.

    PubMed

    Vallabhajosyula, Saraschandra; Sakhuja, Ankit; Geske, Jeffrey B; Kumar, Mukesh; Poterucha, Joseph T; Kashyap, Rahul; Kashani, Kianoush; Jaffe, Allan S; Jentzer, Jacob C

    2017-09-09

    Troponin-T elevation is seen commonly in sepsis and septic shock patients admitted to the intensive care unit. We sought to evaluate the role of admission and serial troponin-T testing in the prognostication of these patients. This was a retrospective cohort study from 2007 to 2014 on patients admitted to the intensive care units at the Mayo Clinic with severe sepsis and septic shock. Elevated admission troponin-T and significant delta troponin-T were defined as ≥0.01 ng/mL and ≥0.03 ng/mL in 3 hours, respectively. The primary outcome was in-hospital mortality. Secondary outcomes included 1-year mortality and lengths of stay. During this 8-year period, 944 patients met the inclusion criteria with 845 (90%) having an admission troponin-T ≥0.01 ng/mL. Serial troponin-T values were available in 732 (78%) patients. Elevated admission troponin-T was associated with older age, higher baseline comorbidity, and severity of illness, whereas significant delta troponin-T was associated with higher severity of illness. Admission log 10 troponin-T was associated with unadjusted in-hospital (odds ratio 1.6; P =0.003) and 1-year mortality (odds ratio 1.3; P =0.04), but did not correlate with length of stay. Elevated delta troponin-T and log 10 delta troponin-T were not significantly associated with any of the primary or secondary outcomes. Admission log 10 troponin-T remained an independent predictor of in-hospital mortality (odds ratio 1.4; P =0.04) and 1-year survival (hazard ratio 1.3; P =0.008). In patients with sepsis and septic shock, elevated admission troponin-T was associated with higher short- and long-term mortality. Routine serial troponin-T testing did not add incremental prognostic value in these patients. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. Characterization of a distinct subgroup of high-risk persons with Kaposi's sarcoma and good prognosis who present with normal T4 cell number and T4:T8 ratio and negative HTLV-III/LAV serologic test results.

    PubMed

    Afrasiabi, R; Mitsuyasu, R T; Nishanian, P; Schwartz, K; Fahey, J L

    1986-12-01

    Three homosexual male patients with biopsy-proved Kaposi's sarcoma were classified as having the acquired immune deficiency syndrome (AIDS) by Centers for Disease Control criteria when first seen in 1983 and 1984. These patients, however, differed from most patients with AIDS and Kaposi's sarcoma in having normal CD4 cell numbers and normal CD4:CD8 ratio. Furthermore, these immunologic parameters remained normal for eight to 24 months of follow-up, and the disease did not progress. Results of recent testing of serum from these patients were negative for HTLV-III/LAV antibodies. The Kaposi's sarcoma was limited to skin (stage I tumors) and the patients did not have persistent lymphadenopathy, fever, night sweats, or weight loss. In contrast to AIDS, the serum immunoglobulin levels (IgG, IgA, IgM) and number of B cells that were spontaneously forming immunoglobulin were within normal range with no evidence of polyclonal activation. The lymphocyte proliferative responses to phytohemagglutinin and Candida were reduced in two of the three patients, and skin test anergy was observed in the two patients tested. These findings are not frequently encountered in other healthy, homosexually active men or in classic Kaposi's sarcoma. They may be indicative of functional T cell changes (without numerical changes) induced by factors other than HTLV-III/LAV virus, which made these homosexually active men susceptible to development of low-grade Kaposi's sarcoma lesions.

  7. 30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF SOUTH SIDE OF FACILITY, INCLUDING BUNKER, CABLE CHASE, SHIELDING TANK, AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-2. INEL INDEX CODE NUMBER: 075 0701 851 151971. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  8. NCHRP report 350 test 3-11 of the modified T8 bridge rail.

    DOT National Transportation Integrated Search

    2009-04-01

    A new flexible bridge rail system, referred to as the T8 rail, was designed as a replacement for the T6 rail in high-speed applications on culverts and thin deck structures. The T8 rail failed a crash test when the breakaway posts failed the thin dec...

  9. Quantification of myocardial oxygenation in heart failure using blood-oxygen-level-dependent T2* magnetic resonance imaging: Comparison with cardiopulmonary exercise test.

    PubMed

    Nagao, Michinobu; Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Higo, Taiki; Ide, Tomomi; Takemura, Atsushi; Ishizaki, Umiko; Fukushima, Kenji; Watanabe, Yuji; Honda, Hiroshi

    2017-06-01

    Quantification of myocardial oxygenation (MO) in heart failure (HF) has been less than satisfactory. This has necessitated the use of invasive techniques to measure MO directly or to determine the oxygen demand during exercise using the cardiopulmonary exercise (CPX) test. We propose a new quantification method for MO using blood-oxygen-level-dependent (BOLD) myocardial T2* magnetic resonance imaging (M-T2* MRI), and investigate its correlation with CPX results. Thirty patients with refractory HF who underwent cardiac MRI and CPX test for heart transplantation, and 24 healthy, age-matched volunteers as controls were enrolled. M-T2* imaging was performed using a 3-Tesla and multi-echo gradient-echo sequence. M-T2* was calculated by fitting the signal intensity data for the mid-left ventricular septum to a decay curve. M-T2* was measured under room-air (T2*-air) and after inhalation of oxygen for 10min at a flow rate of 10L/min (T2*-oxy). MO was defined as the difference between the two values (ΔT2*). Changes in M-T2* at the two conditions and ΔT2* between the two groups were compared. Correlation between ΔT2* and CPX results was analyzed using the Pearson coefficient. T2*-oxy was significantly greater than T2*-air in patients with HF (29.9±7.3ms vs. 26.7±6.0ms, p<0.001), whereas no such difference was observed in controls (25.5±4.0ms vs. 25.4±4.4ms). ΔT2* was significantly greater for patients with HF than for controls (3.2±4.5ms vs. -0.1±1.3ms, p<0.001). A significant correlation between ΔT2* and CPX results (peak VO 2 , r=-0.46, p<0.05; O 2 pulse, r=-0.54, p<0.005) was observed. ΔT2* is increased T2*-oxy is greater in patients with HF, and is correlated with oxygen metabolism during exercise as measured by the CPX test. Hence, ΔT2* can be used as a surrogate marker of MO instead of CPX test. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Evidence-based best practices for EGFR T790M testing in lung cancer in Canada.

    PubMed

    Stockley, T; Souza, C A; Cheema, P K; Melosky, B; Kamel-Reid, S; Tsao, M S; Spatz, A; Karsan, A

    2018-04-01

    Epidermal growth factor receptor (egfr) tyrosine kinase inhibitors (tkis) are recommended as first-line systemic therapy for patients with non-small-cell lung cancer (nsclc) having mutations in the EGFR gene. Resistance to tkis eventually occurs in all nsclc patients treated with such drugs. In patients with resistance to tkis caused by the EGFR T790M mutation, the third-generation tki osimertinib is now the standard of care. For optimal patient management, accurate EGFR T790M testing is required. A multidisciplinary working group of pathologists, laboratory medicine specialists, medical oncologists, a respirologist, and a thoracic radiologist from across Canada was convened to discuss best practices for EGFR T790M mutation testing in Canada. The group made recommendations in the areas of the testing algorithm and the pre-analytic, analytic, and post-analytic aspects of clinical testing for both tissue testing and liquid biopsy circulating tumour dna testing. The recommendations aim to improve EGFR T790M testing in Canada and to thereby improve patient care.

  11. An Overview of Preliminary Computational and Experimental Results for the Semi-Span Super-Sonic Transport (S4T) Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Perry, Boyd, III; Florance, James R.; Sanetrik, Mark D.; Wieseman, Carol D.; Stevens, William L.; Funk, Christie J.; Hur, Jiyoung; Christhilf, David M.; Coulson, David A.

    2011-01-01

    A summary of computational and experimental aeroelastic and aeroservoelastic (ASE) results for the Semi-Span Super-Sonic Transport (S4T) wind-tunnel model is presented. A broad range of analyses and multiple ASE wind-tunnel tests of the S4T have been performed in support of the ASE element in the Supersonics Program, part of NASA's Fundamental Aeronautics Program. The computational results to be presented include linear aeroelastic and ASE analyses, nonlinear aeroelastic analyses using an aeroelastic CFD code, and rapid aeroelastic analyses using CFD-based reduced-order models (ROMs). Experimental results from two closed-loop wind-tunnel tests performed at NASA Langley's Transonic Dynamics Tunnel (TDT) will be presented as well.

  12. Conventional physical therapy and physical therapy based on reflex stimulation showed similar results in children with myelomeningocele.

    PubMed

    Aizawa, Carolina Y P; Morales, Mariana P; Lundberg, Carolina; Moura, Maria Clara D Soares de; Pinto, Fernando C G; Voos, Mariana C; Hasue, Renata H

    2017-03-01

    We aimed to investigate whether infants with myelomeningocele would improve their motor ability and functional independence after ten sessions of physical therapy and compare the outcomes of conventional physical therapy (CPT) to a physical therapy program based on reflex stimulation (RPT). Twelve children were allocated to CPT (n = 6, age 18.3 months) or RPT (n = 6, age 18.2 months). The RPT involved proprioceptive neuromuscular facilitation. Children were assessed with the Gross Motor Function Measure and the Pediatric Evaluation of Disability Inventory before and after treatment. Mann-Whitney tests compared the improvement on the two scales of CPT versus RPT and the Wilcoxon test compared CPT to RPT (before vs. after treatment). Possible correlations between the two scales were tested with Spearman correlation coefficients. Both groups showed improvement on self-care and mobility domains of both scales. There were no differences between the groups, before, or after intervention. The CPT and RPT showed similar results after ten weeks of treatment.

  13. Next-generation avionics packaging and cooling 'test results from a prototype system'

    NASA Astrophysics Data System (ADS)

    Seals, J. D.

    The author reports on the design, material characteristics, and test results obtained under the US Air Force's advanced aircraft avionics packaging technologies (AAAPT) program, whose charter is to investigate new designs and technologies for reliable packaging, interconnection, and thermal management. Under this program, AT&T Bell Laboratories has completed the preliminary testing of and is evaluating a number of promising materials and technologies, including conformal encapsulation, liquid flow-through cooling, and a cyanate ester backplane. A fifty-two module system incorporating these and and other technologies has undergone preliminary cooling efficiency, shock, sine and random vibration, and maintenance testing. One of the primary objectives was to evaluate the interaction compatibility of new materials and designs with other components in the system.

  14. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  15. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...

  16. 40 CFR 799.12 - Test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...

  17. 11. Exterior view, showing instrumentation and gauge panel at walkin ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Exterior view, showing instrumentation and gauge panel at walk-in entry level (bottom) of Test Cell 7, Systems Integration Laboratory Building (T-28), looking west. Metal stair at left leads to working platform levels surrounding test cell. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. Diagnostic Accuracy and Feasibility of Serological Tests on Filter Paper Samples for Outbreak Detection of T.b. gambiense Human African Trypanosomiasis

    PubMed Central

    Hasker, Epco; Lutumba, Pascal; Mumba, Dieudonné; Lejon, Veerle; Büscher, Phillipe; Kande, Victor; Muyembe, Jean Jacques; Menten, Joris; Robays, Jo; Boelaert, Marleen

    2010-01-01

    Control of human African trypanosomiasis (HAT) in the Democratic Republic of Congo is based on mass population screening by mobile teams; a costly and labor-intensive approach. We hypothesized that blood samples collected on filter paper by village health workers and processed in a central laboratory might be a cost-effective alternative. We estimated sensitivity and specificity of micro-card agglutination test for trypanosomiasis (micro-CATT) and enzyme-linked immunosorbent assay (ELISA)/T.b. gambiense on filter paper samples compared with parasitology-based case classification and used the results in a Monte Carlo simulation of a lot quality assurance sampling (LQAS) approach. Micro-CATT and ELISA/T.b. gambiense showed acceptable sensitivity (92.7% [95% CI 87.4–98.0%] and 82.2% [95% CI 75.3–90.4%]) and very high specificity (99.4% [95% CI 99.0–99.9%] and 99.8% [95% CI 99.5–100%]), respectively. Conditional on high sample size per lot (≥ 60%), both tests could reliably distinguish a 2% from a zero prevalence at village level. Alternatively, these tests could be used to identify individual HAT suspects for subsequent confirmation. PMID:20682885

  19. Use of "t"-Test and ANOVA in Career-Technical Education Research

    ERIC Educational Resources Information Center

    Rojewski, Jay W.; Lee, In Heok; Gemici, Sinan

    2012-01-01

    Use of t-tests and analysis of variance (ANOVA) procedures in published research from three scholarly journals in career and technical education (CTE) during a recent 5-year period was examined. Information on post hoc analyses, reporting of effect size, alpha adjustments to account for multiple tests, power, and examination of assumptions…

  20. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T

    PubMed Central

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav

    2017-01-01

    Objectives: To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Methods: Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. Results: TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). Conclusions: MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T. PMID:27704872

  1. Evaluating students' perception of their clinical placements - testing the clinical learning environment and supervision and nurse teacher scale (CLES + T scale) in Germany.

    PubMed

    Bergjan, Manuela; Hertel, Frank

    2013-11-01

    Clinical nursing education in Germany has not received attention in nursing science and practice for a long time, as it often seems to be a more or less "formalized appendix" of nursing education. Several development projects of clinical education taking place are mainly focused on the qualification of clinical preceptors. However, the clinical context and its influence on learning processes have still not been sufficiently investigated. The aim of this study was the testing of a German version of the clinical learning environment and supervision and nurse teacher scale (CLES + T scale). The sample of the pilot study consists of first-, second- and third-year student nurses (n=240) of a university nursing school from January to March 2011. Psychometric testing of the instrument is carried out by selected methods of classical testing theories using SPPS 19. The results show transferability of all subcategories of the CLES + T scale in the non-academic nursing education system of a university hospital in Germany, without the teacher scale. The strongest factor is "supervisory relationship". The German version of the CLES + T scale may help to evaluate and compare traditional and new models in clinical nursing education. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Statistical power comparisons at 3T and 7T with a GO / NOGO task.

    PubMed

    Torrisi, Salvatore; Chen, Gang; Glen, Daniel; Bandettini, Peter A; Baker, Chris I; Reynolds, Richard; Yen-Ting Liu, Jeffrey; Leshin, Joseph; Balderston, Nicholas; Grillon, Christian; Ernst, Monique

    2018-07-15

    The field of cognitive neuroscience is weighing evidence about whether to move from standard field strength to ultra-high field (UHF). The present study contributes to the evidence by comparing a cognitive neuroscience paradigm at 3 Tesla (3T) and 7 Tesla (7T). The goal was to test and demonstrate the practical effects of field strength on a standard GO/NOGO task using accessible preprocessing and analysis tools. Two independent matched healthy samples (N = 31 each) were analyzed at 3T and 7T. Results show gains at 7T in statistical strength, the detection of smaller effects and group-level power. With an increased availability of UHF scanners, these gains may be exploited by cognitive neuroscientists and other neuroimaging researchers to develop more efficient or comprehensive experimental designs and, given the same sample size, achieve greater statistical power at 7T. Published by Elsevier Inc.

  3. In routine UK hospital practice T-SPOT.TB™ is useful in some patients with a modest pre-test probability of active tuberculosis.

    PubMed

    Turtle, Lance; Kemp, Tim; Davies, Geraint R; Squire, S Bertie; Beeching, Nick J; Beadsworth, Michael B J

    2012-06-01

    to assess the usefulness of the T-SPOT.TB™ interferon-gamma release assay (IGRA), as used in a regional hospital infectious diseases unit in Northwest England, for the diagnosis of active tuberculosis. Retrospective case series. T-SPOT.TB™ test was applied to a group of 64 patients, 20 of whom had tuberculosis (mostly extra-pulmonary tuberculosis). The T-SPOT.TB™ test had a sensitivity of 83.3% and a specificity of 75% for the diagnosis of active tuberculosis, compared with culture. A positive IGRA approximately doubled the pre-test probability of disease from 0.23 to 0.5. This doubling of probability was true regardless of HIV status, though for HIV+ patients the sensitivity was lower (sensitivity 66.7%, post test probability 0.4 for a positive IGRA result). When extrapolated to the local population the test was most useful for exclusion of disease; post test probability 0.006 (or 1 in 167) for a negative IGRA result. Although it can add weight to a clinical diagnosis, T-SPOT.TB™ assay is not reliable for the diagnosis of active tuberculosis in a real world setting where the test is often used in patients with smear negative or extra-pulmonary disease. The test is useful for ruling out disease in HIV negative patients. Copyright © 2012. Published by Elsevier B.V.

  4. Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.

    2001-01-01

    This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

  5. Constitutive Model Constants for Al7075-T651 and Al7075-T6

    NASA Astrophysics Data System (ADS)

    Brar, N. S.; Joshi, V. S.; Harris, B. W.

    2009-12-01

    Aluminum 7075-T651 and 7075-T6 are characterized at quasi-static and high strain rates to determine Johnson-Cook (J-C) strength and fracture model constants. Constitutive model constants are required as input to computer codes to simulate projectile (fragment) impact or similar impact events on structural components made of these materials. Although the two tempers show similar elongation at breakage, the ultimate tensile strength of T651 temper is generally lower than the T6 temper. Johnson-Cook strength model constants (A, B, n, C, and m) for the two alloys are determined from high strain rate tension stress-strain data at room and high temperature to 250°C. The Johnson-Cook fracture model constants are determined from quasi-static and medium strain rate as well as high temperature tests on notched and smooth tension specimens. Although the J-C strength model constants are similar, the fracture model constants show wide variations. Details of the experimental method used and the results for the two alloys are presented.

  6. New results from T2K

    NASA Astrophysics Data System (ADS)

    Longhin, A.

    2017-12-01

    The T2K experiment is a 295-km long-baseline neutrino experiment in Japan employing an off-axis muon neutrino beam with a 0.6 GeV peak energy. The beam, produced from 30-GeV protons at the J-PARC complex on the Pacific coast, is directed to the Super-Kamiokande detector. T2K released the first long-baseline measurement of a nonzero value for the θ13 mixing parameter through the observation of electron neutrino appearance (vµ → ve) and produced the most precise measurement of θ23 through the observation of muon neutrino disappearance (vµ → vµ). T2K data, in combination with reactor experiments, also excludes at 90% C.L. a significant region of the Dirac CP phase: δCP < -3.02(-1.87) and δCP > -0.49(-0.98) for the normal (inverted) hierarchy. A full joint appearance and disappearance fit including both neutrino (7×1020 protons on target, PoT) and anti-neutrino (4 × 1020 PoT) data and, for the first time, a constraint from water target data in the near detector, is presented yielding improved sensitivity on δCP and improved precision on sin2 2θ23 and the atmospheric mass splitting.

  7. Results of industrial tests of carbonate additive to fuel oil

    NASA Astrophysics Data System (ADS)

    Zvereva, E. R.; Dmitriev, A. V.; Shageev, M. F.; Akhmetvalieva, G. R.

    2017-08-01

    Fuel oil plays an important role in the energy balance of our country. The quality of fuel oil significantly affects the conditions of its transport, storage, and combustion; release of contaminants to atmosphere; and the operation of main and auxiliary facilities of HPPs. According to the Energy Strategy of Russia for the Period until 2030, the oil-refining ratio gradually increases; as a result, the fraction of straight-run fuel oil in heavy fuel oils consistently decreases, which leads to the worsening of performance characteristics of fuel oil. Consequently, the problem of the increase in the quality of residual fuel oil is quite topical. In this paper, it is suggested to treat fuel oil by additives during its combustion, which would provide the improvement of ecological and economic indicators of oil-fired HPPs. Advantages of this method include simplicity of implementation, low energy and capital expenses, and the possibility to use production waste as additives. In the paper, the results are presented of industrial tests of the combustion of fuel oil with the additive of dewatered carbonate sludge, which is formed during coagulation and lime treatment of environmental waters on HPPs. The design of a volume delivery device is developed for the steady additive input to the boiler air duct. The values are given for the main parameters of the condition of a TGM-84B boiler plant. The mechanism of action of dewatered carbonate sludge on sulfur oxides, which are formed during fuel oil combustion, is considered. Results of industrial tests indicate the decrease in the mass fraction of discharged sulfur oxides by 36.5%. Evaluation of the prevented damage from sulfur oxide discharged into atmospheric air shows that the combustion of the fuel oil of 100 brand using carbonate sludge as an additive (0.1 wt %) saves nearly 6 million rubles a year during environmental actions at the consumption of fuel oil of 138240 t/year.

  8. 13. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF POOR CONSTRUCTION WORK. THOUGH NOT A SERIOUS STRUCTURAL DEFICIENCY, THE 'HONEYCOMB' TEXTURE OF THE CONCRETE SURFACE WAS THE RESULT OF INADEQUATE TAMPING AT THE TIME OF THE INITIAL 'POUR'. - Hume Lake Dam, Sequioa National Forest, Hume, Fresno County, CA

  9. Multivariate Welch t-test on distances.

    PubMed

    Alekseyenko, Alexander V

    2016-12-01

    Permutational non-Euclidean analysis of variance, PERMANOVA, is routinely used in exploratory analysis of multivariate datasets to draw conclusions about the significance of patterns visualized through dimension reduction. This method recognizes that pairwise distance matrix between observations is sufficient to compute within and between group sums of squares necessary to form the (pseudo) F statistic. Moreover, not only Euclidean, but arbitrary distances can be used. This method, however, suffers from loss of power and type I error inflation in the presence of heteroscedasticity and sample size imbalances. We develop a solution in the form of a distance-based Welch t-test, [Formula: see text], for two sample potentially unbalanced and heteroscedastic data. We demonstrate empirically the desirable type I error and power characteristics of the new test. We compare the performance of PERMANOVA and [Formula: see text] in reanalysis of two existing microbiome datasets, where the methodology has originated. The source code for methods and analysis of this article is available at https://github.com/alekseyenko/Tw2 Further guidance on application of these methods can be obtained from the author. alekseye@musc.edu. © The Author 2016. Published by Oxford University Press.

  10. Test Result of the Short Models MQXFS3 and MQXFS5 for the HL-LHC Upgrade

    DOE PAGES

    Bajas, Hugues; Ambrosio, Giorgio; Ballarino, A.; ...

    2018-02-27

    In the framework of the High-Luminosity Large Hadron Collider, the installation of a new generation of quadrupole magnets is foreseen on each side of ATLAS and CMS experiments. The new magnets are based on Nbmore » $$_{3}$$Sn technology and shall be able to reach an ultimate current of 17.9 kA with a peak field of 12.3 T in the coil. In 2016 and 2017, the first two short models, called MQXFS3 and MQXFS5, have been tested at 4.2 and 1.9 K in the two new test benches at the European Organization for Nuclear Research. This paper presents the result of the quench performance of the two models; the first magnet reached nominal but failed to reach ultimate, showing detraining in one coil. MQXFS5 reached ultimate performance without any detraining phenomena, validating the PIT conductor used for the first time in this magnet program.« less

  11. Test Result of the Short Models MQXFS3 and MQXFS5 for the HL-LHC Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bajas, Hugues; Ambrosio, Giorgio; Ballarino, A.

    In the framework of the High-Luminosity Large Hadron Collider, the installation of a new generation of quadrupole magnets is foreseen on each side of ATLAS and CMS experiments. The new magnets are based on Nbmore » $$_{3}$$Sn technology and shall be able to reach an ultimate current of 17.9 kA with a peak field of 12.3 T in the coil. In 2016 and 2017, the first two short models, called MQXFS3 and MQXFS5, have been tested at 4.2 and 1.9 K in the two new test benches at the European Organization for Nuclear Research. This paper presents the result of the quench performance of the two models; the first magnet reached nominal but failed to reach ultimate, showing detraining in one coil. MQXFS5 reached ultimate performance without any detraining phenomena, validating the PIT conductor used for the first time in this magnet program.« less

  12. Comparisons between Murine Polyomavirus and Simian Virus 40 Show Significant Differences in Small T Antigen Function ▿

    PubMed Central

    Andrabi, Shaida; Hwang, Justin H.; Choe, Jennifer Kean; Roberts, Thomas M.; Schaffhausen, Brian S.

    2011-01-01

    Although members of a virus family produce similar gene products, those products may have quite different functions. Simian virus 40 (SV40) large T antigen (LT), for example, targets p53 directly, but murine polyomavirus LT does not. SV40 small T antigen (SVST) has received considerable attention because of its ability to contribute to transformation of human cells. Here, we show that there are major differences between SVST and polyomavirus small T antigen (POLST) in their effects on differentiation, transformation, and cell survival. Both SVST and POLST induce cell cycle progression. However, POLST also inhibits differentiation of 3T3-L1 preadipocytes and C2C12 myoblasts. Additionally, POLST induces apoptosis of mouse embryo fibroblasts. SVST reduces the proapoptotic transcriptional activity of FOXO1 through phosphorylation. On the other hand, SVST complements large T antigen and Ras for the transformation of human mammary epithelial cells (HMECs), but POLST does not. Mechanistically, the differences between SVST and POLST may lie in utilization of protein phosphatase 2A (PP2A). POLST binds both Aα and Aβ scaffolding subunits of PP2A while SVST binds only Aα. Knockdown of Aβ could mimic POLST-induced apoptosis. The two small T antigens can target different proteins for dephosphorylation. POLST binds and dephosphorylates substrates, such as lipins, that SVST does not. PMID:21835797

  13. Somatic Hypermutation at A/T-Rich Oligonucleotide Substrates Shows Different Strand Polarities in Ung-Deficient or -Proficient Backgrounds

    PubMed Central

    Zivojnovic, Marija; Delbos, Frédéric; Girelli Zubani, Giulia; Julé, Amélie; Alcais, Alexandre; Storck, Sébastien

    2014-01-01

    A/T mutations at immunoglobulin loci are introduced by DNA polymerase η (Polη) during an Msh2/6-dependent repair process which results in A's being mutated 2-fold more often than T's. This patch synthesis is initiated by a DNA incision event whose origin is still obscure. We report here the analysis of A/T oligonucleotide mutation substrates inserted at the heavy chain locus, including or not including internal C's or G's. Surprisingly, the template composed of only A's and T's was highly mutated over its entire 90-bp length, with a 2-fold decrease in mutation from the 5′ to the 3′ end and a constant A/T ratio of 4. These results imply that Polη synthesis was initiated from a break in the 5′-flanking region of the substrate and proceeded over its entire length. The A/T bias was strikingly altered in an Ung−/− background, which provides the first experimental evidence supporting a concerted action of Ung and Msh2/6 pathways to generate mutations at A/T bases. New analysis of Pms2−/− animals provided a complementary picture, revealing an A/T mutation ratio of 4. We therefore propose that Ung and Pms2 may exert a mutual backup function for the DNA incision that promotes synthesis by Polη, each with a distinct strand bias. PMID:24710273

  14. Methicillin-resistant Staphylococcus aureus isolates with SCCmec type V and spa types t437 or t1081 associated to discordant susceptibility results between oxacillin and cefoxitin, Central Taiwan.

    PubMed

    Ho, Cheng-Mao; Lin, Chien-Yu; Ho, Mao-Wang; Lin, Hsiao-Chuan; Chen, Chao-Jung; Lin, Lee-Chung; Lu, Jang-Jih

    2016-12-01

    Staphylococcus aureus isolates with discordant susceptibility results between oxacillin and cefoxitin obtained using automated microbiology systems are infrequently observed. From April 2013 to December 2014, 1956 methicillin-resistant S. aureus (MRSA) and 1761 methicillin-susceptible S. aureus isolates were obtained from different patients. Forty isolates (1.1% and 2% in case of S. aureus and MRSA, respectively) with discordant susceptibility results (oxacillin susceptible and cefoxitin resistant) and carrying mecA gene were obtained. Except 2 SCCmec type IV isolates, 38 MRSA isolates were all SCCmec type V (V T or non-V T ), which were further divided into V T (n=22) and non-V T (n=16). The most common spa type in V T and non-V T isolates were t437 (n=19) and t1081 (n=13), respectively. Only 55% of patients received effective antimicrobial agents; 2 mortalities were not attributable to MRSA infection. Using standard agar dilution, 17 MRSA isolates (0.46% and 0.87% in case of S. aureus and MRSA, respectively) had oxacillin MIC in the susceptible ranges (oxacillin-susceptible MRSA [OS-MRSA]); all carried SCCmec type V (V T , n=8; non-V T , n=9). The most common spa-MLST types of OS-MRSA in V T and non-V T were t437-ST59 (n=4) and t1081-ST45 (n=7), respectively. Concomitant testing by both cefoxitin- and oxacillin-based methods is a practical strategy for OS-MRSA detection in the clinical laboratories. Continuous monitoring of OS-MRSA isolates is necessary to elucidate their impact in clinical infectious diseases. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Vδ2+ and α/ß T cells show divergent trajectories during human aging.

    PubMed

    Tan, Crystal Tze Ying; Wistuba-Hamprecht, Kilian; Xu, Weili; Nyunt, Ma Schwe Zin; Vasudev, Anusha; Lee, Bernett Teck Kwong; Pawelec, Graham; Puan, Kia Joo; Rotzschke, Olaf; Ng, Tze Pin; Larbi, Anis

    2016-07-19

    Chronological aging and a variety of stressors are driving forces towards immunosenescence. While much attention was paid to the main T cell component, α/β T cells, few studies concentrate on the impact of age on γ/δ T cells' characteristics. The latter are important players of adaptive immunity but also have features associated with innate immunity. Vδ2+ are the main component of γ/δ while Vδ1+ T cells expand upon Cytomegalovirus (CMV) infection and with age. The Vδ2+ T cells are not influenced by persistent infections but do contribute to immunosurveillance against bacterial pathogens. Here, we focus on Vδ2+ T cells and report that their composition and functionality is not altered in older adults. We have performed a side-by-side comparison of α/β and Vδ2 cells by using two robust markers of T cell replicative history and cell differentiation (CD28 and CD27), and cytokine secretion (IFN-γ and TNF-α). Significant differences in Vδ2 versus α/β homeostasis, as well as phenotypic and functional changes emerged. However, the data strongly suggest a sustained functionality of the Vδ2 population with age, independently of the challenge. This suggests differential trajectories towards immunosenescence in α/β and Vδ2+ T cells, most likely explained by their intrinsic functions.

  16. A Report on the Present Status of Engineering Mathematics Test (EMaT)

    NASA Astrophysics Data System (ADS)

    Watanabe, Toshimasa; Takafuji, Daisuke

    The aim of Engineering Mathematics Test (EMaT) is to make sure what essentials in curriculum of Engineering Mathematics is, and to assess university students’ core academic competence and achievement of Engineering Mathematics, helping assurance of students’ academic ability. It is useful for professors to evaluate teaching effect of the classes, and this evaluation would help them improve curricula. Scores can be available for both graduate school entrance examinations and employment tests, leading to selecting persons with basic academic ability in Engineering Mathematics. The scope includes fundamentals in Calculus, Linear Algebra, Differential Equations, and Probability and Statistics. It is open to all students free of charge, and is annually given once in December. In 2007, 2,396 students from 35 universities took EMaT, and the total number of students who have taken EMaT in these 5 years is 6,240.

  17. Test-retest reliability and concurrent validity of in vivo myelin content indices: Myelin water fraction and calibrated T1 w/T2 w image ratio.

    PubMed

    Arshad, Muzamil; Stanley, Jeffrey A; Raz, Naftali

    2017-04-01

    In an age-heterogeneous sample of healthy adults, we examined test-retest reliability (with and without participant repositioning) of two popular MRI methods of estimating myelin content: modeling the short spin-spin (T 2 ) relaxation component of multi-echo imaging data and computing the ratio of T 1 -weighted and T 2 -weighted images (T 1 w/T 2 w). Taking the myelin water fraction (MWF) index of myelin content derived from the multi-component T 2 relaxation data as a standard, we evaluate the concurrent and differential validity of T 1 w/T 2 w ratio images. The results revealed high reliability of MWF and T 1 w/T 2 w ratio. However, we found significant correlations of low to moderate magnitude between MWF and the T 1 w/T 2 w ratio in only two of six examined regions of the cerebral white matter. Notably, significant correlations of the same or greater magnitude were observed for T 1 w/T 2 w ratio and the intermediate T 2 relaxation time constant, which is believed to reflect differences in the mobility of water between the intracellular and extracellular compartments. We conclude that although both methods are highly reliable and thus well-suited for longitudinal studies, T 1 w/T 2 w ratio has low criterion validity and may be not an optimal index of subcortical myelin content. Hum Brain Mapp 38:1780-1790, 2017. © 2017 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. [Roaming through methodology. XXXII. False test results].

    PubMed

    van der Weijden, T; van den Akker, M

    2001-05-12

    The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.

  19. Antidiabetics and diuretics show phototoxicity in HaCaT cells

    NASA Astrophysics Data System (ADS)

    Selvaag, Edgar; Petersen, Anita B.; Gniadecki, Robert; Thorn, Tine; Wulf, Hans Christian

    2001-10-01

    The antidiabetics tolbutamide, glibenclamide, and glipizide, and the diuretics bendroflumethiazide, butizide, furosemide, hydrochlorothiazide, and trichlormethiazide were investigated for potential phototoxicity in the HaCaT cell line. The cells were incubated with the drugs and then exposed to UVA1 irradiation. The effects of the antioxidants L-ascorbic acid, and (alpha) -tocopherol on oxidative DNA damage were assessed. Bendroflumethiazide, furosemide, hydrochlorothiazide, trichlormethiazide, or tolbutamide induced dose-dependent phototoxicity. Cells incubated with bendroflumethiazide, tolbutamide, and glibenclamide, and irradiated with UVA1 demonstrated an increased oxidative DNA damage. Pre-treatment with L-ascorbic acid, or (alpha) -tocopherol, suppressed the UVA-induced DNA damage in cells incubated with 1 mM of bendroflumethiazide, furosemide, glibenclamide, glipizide, tolbutamide, and trichloromethiazide, further implying the involvement of reactive oxygen species in the phototoxic DNA damage. These results may indicate a link between phototoxic and photocancerogenic potential of the sulfonamide-derived oral antidiabetic and diuretic drugs, as it has previously been recognized for psoralen, chlorpromazine, and fluoroquinolones. Excessive exposure to UV light may be deleterious for patients treated with these drugs.

  20. Test – Retest Reliability and Concurrent Validity of in vivo Myelin Content Indices: Myelin Water Fraction and Calibrated T1w/T2w Image Ratio

    PubMed Central

    Arshad, Muzamil; Stanley, Jeffrey A.; Raz, Naftali

    2016-01-01

    In an age-heterogeneous sample of healthy adults, we examined test-retest reliability (with and without participant re-positioning) of two popular MRI methods of estimating myelin content: modeling the short spin-spin (T2) relaxation component of multi-echo imaging data and computing the ratio of T1-weighted and T2-weighted images (T1w/T2w). Taking the myelin water fraction (MWF) index of myelin content derived from the multi-component T2 relaxation data as a standard, we evaluate the concurrent and differential validity of T1w/T2w ratio images. The results revealed high reliability of MWF and T1w/T2w ratio. However, we found significant correlations of low to moderate magnitude between MWF and the T1w/T2w ratio in only two of six examined regions of the cerebral white matter. Notably, significant correlations of the same or greater magnitude were observed for T1w/T2w ratio and the intermediate T2 relaxation time constant, which is believed to reflect differences in the mobility of water between the intracellular and extracellular compartments. We conclude that although both methods are highly reliable and thus well-suited for longitudinal studies, T1w/T2w ratio has low criterion validity and may be not an optimal index of subcortical myelin content. PMID:28009069

  1. Tank 241-T-204, core 188 analytical results for the final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuzum, J.L.

    TANK 241-T-204, CORE 188, ANALYTICAL RESULTS FOR THE FINAL REPORT. This document is the final laboratory report for Tank 241 -T-204. Push mode core segments were removed from Riser 3 between March 27, 1997, and April 11, 1997. Segments were received and extruded at 222-8 Laboratory. Analyses were performed in accordance with Tank 241-T-204 Push Mode Core Sampling and analysis Plan (TRAP) (Winkleman, 1997), Letter of instruction for Core Sample Analysis of Tanks 241-T-201, 241- T-202, 241-T-203, and 241-T-204 (LAY) (Bell, 1997), and Safety Screening Data Qual@ Objective (DO) ODukelow, et al., 1995). None of the subsamples submitted for totalmore » alpha activity (AT) or differential scanning calorimetry (DC) analyses exceeded the notification limits stated in DO. The statistical results of the 95% confidence interval on the mean calculations are provided by the Tank Waste Remediation Systems Technical Basis Group and are not considered in this report.« less

  2. Somatic hypermutation at A/T-rich oligonucleotide substrates shows different strand polarities in Ung-deficient or -proficient backgrounds.

    PubMed

    Zivojnovic, Marija; Delbos, Frédéric; Girelli Zubani, Giulia; Julé, Amélie; Alcais, Alexandre; Weill, Jean-Claude; Reynaud, Claude-Agnès; Storck, Sébastien

    2014-06-01

    A/T mutations at immunoglobulin loci are introduced by DNA polymerase η (Polη) during an Msh2/6-dependent repair process which results in A's being mutated 2-fold more often than T's. This patch synthesis is initiated by a DNA incision event whose origin is still obscure. We report here the analysis of A/T oligonucleotide mutation substrates inserted at the heavy chain locus, including or not including internal C's or G's. Surprisingly, the template composed of only A's and T's was highly mutated over its entire 90-bp length, with a 2-fold decrease in mutation from the 5' to the 3' end and a constant A/T ratio of 4. These results imply that Polη synthesis was initiated from a break in the 5'-flanking region of the substrate and proceeded over its entire length. The A/T bias was strikingly altered in an Ung(-/-) background, which provides the first experimental evidence supporting a concerted action of Ung and Msh2/6 pathways to generate mutations at A/T bases. New analysis of Pms2(-/-) animals provided a complementary picture, revealing an A/T mutation ratio of 4. We therefore propose that Ung and Pms2 may exert a mutual backup function for the DNA incision that promotes synthesis by Polη, each with a distinct strand bias. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  3. Long-Term Trial Results Show No Mortality Benefit from Annual Prostate Cancer Screening

    Cancer.gov

    Thirteen year follow-up data from the Prostate, Lung, Colorectal and Ovarian (PLCO) cancer screening trial show higher incidence but similar mortality among men screened annually with the prostate-specific antigen (PSA) test and digital rectal examination

  4. The Relevance of External Quality Assessment for Molecular Testing for ALK Positive Non-Small Cell Lung Cancer: Results from Two Pilot Rounds Show Room for Optimization

    PubMed Central

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M. C.

    2014-01-01

    Background and Purpose Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012–2013. Materials and Methods Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Results Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. Conclusion There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing. PMID:25386659

  5. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  6. Prediction of anaerobic power values from an abbreviated WAnT protocol.

    PubMed

    Stickley, Christopher D; Hetzler, Ronald K; Kimura, Iris F

    2008-05-01

    The traditional 30-second Wingate anaerobic test (WAnT) is a widely used anaerobic power assessment protocol. An abbreviated protocol has been shown to decrease the mild to severe physical discomfort often associated with the WAnT. Therefore, the purpose of this study was to determine whether a 20-second WAnT protocol could be used to accurately predict power values of a standard 30-second WAnT. In 96 college females, anaerobic power variables were assessed using a standard 30-second WAnT protocol. Maximum power values as well as instantaneous power at 10, 15, and 20 seconds were recorded. Based on these results, stepwise regression analysis was performed to determine the accuracy with which mean power, minimum power, 30-second power, and percentage of fatigue for a standard 30-second WAnT could be predicted from values obtained during the first 20 seconds of testing. Mean power values showed the highest level of predictability (R2 = 0.99) from the 20-second values. Minimum power, 30-second power, and percentage of fatigue also showed high levels of predictability (R2 = 0.91, 0.84, and 0.84, respectively) using only values obtained during the first 20 seconds of the protocol. An abbreviated (20-second) WAnT protocol appears to effectively predict results of a standard 30-second WAnT in college-age females, allowing for comparison of data to published norms. A shortened test may allow for a decrease in unwanted side effects associated with the traditional WAnT protocol.

  7. Observational tests for Λ(t)CDM cosmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pigozzo, C.; Carneiro, S.; Dantas, M.A.

    2011-08-01

    We investigate the observational viability of a class of cosmological models in which the vacuum energy density decays linearly with the Hubble parameter, resulting in a production of cold dark matter particles at late times. Similarly to the flat ΛCDM case, there is only one free parameter to be adjusted by the data in this class of Λ(t)CDM scenarios, namely, the matter density parameter. To perform our analysis we use three of the most recent SNe Ia compilation sets (Union2, SDSS and Constitution) along with the current measurements of distance to the BAO peaks at z = 0.2 and zmore » = 0.35 and the position of the first acoustic peak of the CMB power spectrum. We show that in terms of χ{sup 2} statistics both models provide good fits to the data and similar results. A quantitative analysis discussing the differences in parameter estimation due to SNe light-curve fitting methods (SALT2 and MLCS2k2) is studied using the current SDSS and Constitution SNe Ia compilations. A matter power spectrum analysis using the 2dFGRS is also performed, providing a very good concordance with the constraints from the SDSS and Constitution MLCS2k2 data.« less

  8. 8. Exterior view, showing tank and associated piping adjacent to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Exterior view, showing tank and associated piping adjacent to Test Cell 6, Systems Integration Laboratory Building (T-28), looking south. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  9. The relevance of external quality assessment for molecular testing for ALK positive non-small cell lung cancer: results from two pilot rounds show room for optimization.

    PubMed

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M C

    2014-01-01

    Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012-2013. Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing.

  10. Characteristics of Control Laws Tested on the Semi-Span Super-Sonic Transport (S4T) Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Christhilf, David M.; Moulin, Boris; Ritz, Erich; Chen, P. C.; Roughen, Kevin M.; Perry, Boyd

    2012-01-01

    The Semi-Span Supersonic Transport (S4T) is an aeroelastically scaled wind-tunnel model built to test active controls concepts for large flexible supersonic aircraft in the transonic flight regime. It is one of several models constructed in the 1990's as part of the High Speed Research (HSR) Program. Control laws were developed for the S4T by M4 Engineering, Inc. and by Zona Technologies, Inc. under NASA Research Announcement (NRA) contracts. The model was tested in the NASA-Langley Transonic Dynamics Tunnel (TDT) four times from 2007 to 2010. The first two tests were primarily for plant identification. The third entry was used for testing control laws for Ride Quality Enhancement, Gust Load Alleviation, and Flutter Suppression. Whereas the third entry only tested FS subcritically, the fourth test demonstrated closed-loop operation above the open-loop flutter boundary. The results of the third entry are reported elsewhere. This paper reports on flutter suppression results from the fourth wind-tunnel test. Flutter suppression is seen as a way to provide stability margins while flying at transonic flight conditions without penalizing the primary supersonic cruise design condition. An account is given for how Controller Performance Evaluation (CPE) singular value plots were interpreted with regard to progressing open- or closed-loop to higher dynamic pressures during testing.

  11. Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

    NASA Technical Reports Server (NTRS)

    Oppenheimer, Frank L.; Lazar, James

    1951-01-01

    A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

  12. Multipacting simulation and test results of BNL 704 MHz SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu W.; Belomestnykh, S.; Ben-Zvi, I.

    The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab,more » and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.« less

  13. Hybrid TE panel test results

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1972-01-01

    Test results are presented for a nine couple (3 x 3 array) thermoelectric panel of hybrid thermocouples. In the hybrid couple, a hollow cylinder of p-type Si-Ge is used to encapsulate a segmented PbTe/Si-Ge n-leg. The hybrid couple is predicted to offer a 10- to 15-percent improvement in performance relative to all Si-Ge couples. The efficiency, output power, and internal resistance of the panel as well as the resistances of the individual hybrid couples are presented as a function of test time covering a period of more than 2600 hours. Initial test results indicated hybrid couple performance consistent with design predictions. Extraneous resistance ranged from 20 to 25% of the hybrid couple thermoelectric resistance.

  14. 1. Exterior view of Components Test Laboratory (T27), looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Components Test Laboratory (T-27), looking southeast from hill north of structure. The building wing in the right foreground houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. Test Cell 10 is located in the center background, Test Cell 9 is at the far left, and the equipment room is in the immediate left foreground. The control room is in the center of the structure and abuts the aforementioned test cell and equipment room wings. This structure served as a facility for testing, handling, and storage of Titan II's hydrazine- and nitrogen teteroxide-based propellant system components for compatability determinations. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  15. [Leigh syndrome resulting from a de novo mitochondrial DNA mutation (T8993G)].

    PubMed

    Playán, A; Solano-Palacios, A; González de la Rosa, J B; Merino-Arribas, J M; Andreu, A L; López-Pérez, M; Montoya, J

    Several degenerative neurological diseases are caused by mutations in the mitochondrial gene coding for subunit 6 of the ATPase. Thus, NARP (neurogenic weakness, ataxia, and retinitis pigmentosa) and Leigh syndromes are associated to a T8993G mutation when the percentage of mutant mitochondrial DNA is low (60 90%) or high (>90%), respectively. Leigh syndrome is also caused by a second mutation in the same position T8993C. The patient, a boy that died at 6 months, had generalized hypotonia, psychomotor delay, hepatomegaly, choreic movements and hyporreflexia. MRI showed hypodensities in the basal ganglia and brain stem as well as hyperlactacidemia. Molecular genetic analysis of the mitochondrial DNA showed that the patient had the T8993G mutation in a percentage higher than 95%. No mutated DNA was detected in blood of the proband s mother, maternal aunt and grandmother. The point mutation T8993G may occur de novo, at high levels, causing neurodegenerative diseases.

  16. Test Results for the 2.5-kVA Ground Fault Detector.

    DTIC Science & Technology

    1986-01-01

    powered through Q1 is delayed in turning off by capacitor C4 for approximately 12 msec. When the relay does drop out, the triac Q7 (a bidirectional...SECONDS) CALBIRATIONS, ETC.) / / -. L a 2 33 ( j4 -40 7 S’f9 I! Note time of con pletlon o test series . .I1 " , -3 TEST DATA FORM Bc (CONTINUATION...test series . 2 *51/7 ,6. L7.. i K-t TEST CATA FORM D OCEAN OPERABILITY TESTS FOR ELEETRIC FIELD DETECTOR AND GROUND FAULT DETECTORS This data form is to

  17. A cane reduces loss of balance in patients with peripheral neuropathy: results from a challenging unipedal balance test.

    PubMed

    Ashton-Miller, J A; Yeh, M W; Richardson, J K; Galloway, T

    1996-05-01

    To test the hypothesis that use of a cane in the nondominant hand during challenging balance tasks would significantly decrease loss of balance in patients with peripheral neuropathy while transferring from bipedal to unipedal stance on an unsteady surface. Nonrandomized control study. Tertiary-care institution. Eight consecutive patients with peripheral neuropathy (PN) and eight age- and gender-matched controls (C) with a mean (SD) age of 65 (8.2) years. Subjects were asked to transfer their weight onto their right foot, despite a rapid +/- 2 degrees or +/- 4 degrees frontal plane tilt of the support surface at 70% of weight transfer, and balance unipedally for at least 3 seconds. The efficacy of their weight transfer was evaluated over 112 consecutive randomized and blocked trials by calculating loss of balance as failure rates (%FR) with and without visual feedback, and with and without use of a cane in the nondominant (left) hand. Results were analyzed using a 2 x 2 x 2 x 2 x 2 repeated-measures analysis of variance (rm-ANOVA) and post hoc t tests. The rm-ANOVA showed that the FR of the PN subjects (47.6% [18.1%]) was significantly higher than C (29.2% [15.2%], p = .036). Removing visual feedback, simulating the dark of night, increased the FR fourfold (p = .000). Use of a cane in the contralateral nondominant hand significantly reduced the FR (p = .000), particularly in the PN group (cane x disease interaction: p = .055). Post hoc t tests showed that with or without visual feedback, the cane reduced the FR of the PN group fourfold and enabled them to perform more reliably than matched controls not using a cane (p = .011). An inversion perturbation resulted in a higher FR than an eversion perturbation (p = .007). The PN group employed larger mean peak cane forces (21.9% BW) than C (13.6% BW) in restoring their balance (p = .000). Use of a cane by PN patients significantly reduced their risk of losing balance on unstable surfaces, especially under low

  18. 14. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. DETAIL VIEW OF BUTTRESS 4 SHOWING THE RESULTS OF INADEQUATE TAMPING. THE SIZE OF THE GRANITE AGGREGATE USED IN THE DAMS CONCRETE IS CLEARLY SHOWN. - Hume Lake Dam, Sequioa National Forest, Hume, Fresno County, CA

  19. External quality assessment for CD4 + T-lymphocyte count test

    PubMed Central

    Gaspar, Pâmela Cristina; Wohlke, Bruna Lovizutto Protti; Brunialti, Milena Karina Coló; Pires, Ana Flávia; Kohiyama, Igor Massaki; Salomão, Reinaldo; Alonso Neto, José Boullosa; Júnior, Orlando da Costa Ferreira; Franchini, Miriam; Bazzo, Maria Luiza; Benzaken, Adele Schwartz

    2018-01-01

    Abstract The National Network for CD4+ T-lymphocyte counting of Brazil comprises 93 laboratories. This study reports the laboratory performances achieved in external quality assessment (EQA) rounds provides by Ministry of Health to evaluate the quality of the kits used and the performance of test by the technicians. Ten EQA rounds were analyzed according the EQA criteria aimed to evaluate individual laboratory performance on the basis of the accuracy of their results compared to the general mean obtained by all participating laboratories and the reproducibility of the results obtained between 2 samples from the same donor. The percentage of approved and failed laboratories in the EQAs tends to follow a uniform pattern. Since 2011, approval has remained above 80% and the failure rate has never exceeded 15%. EQA is very important to evaluate the performance of the laboratories, to identify monitor, and to resolve errors as quickly as possible. PMID:29794603

  20. A statistical test to show negligible trend

    Treesearch

    Philip M. Dixon; Joseph H.K. Pechmann

    2005-01-01

    The usual statistical tests of trend are inappropriate for demonstrating the absence of trend. This is because failure to reject the null hypothesis of no trend does not prove that null hypothesis. The appropriate statistical method is based on an equivalence test. The null hypothesis is that the trend is not zero, i.e., outside an a priori specified equivalence region...

  1. State Test Results Are Predictable

    ERIC Educational Resources Information Center

    Tienken, Christopher H.

    2014-01-01

    Out-of-school, community demographic and family-level variables have an important influence on student achievement as measured by large-scale standardized tests. Studies described here demonstrated that about half of the test score is accounted for by variables outside the control of teachers and school administrators. The results from these…

  2. Surra Sero K-SeT, a new immunochromatographic test for serodiagnosis of Trypanosoma evansi infection in domestic animals.

    PubMed

    Birhanu, Hadush; Rogé, Stijn; Simon, Thomas; Baelmans, Rudy; Gebrehiwot, Tadesse; Goddeeris, Bruno Maria; Büscher, Philippe

    2015-07-30

    Trypanosoma evansi, the causative agent of surra, infects different domestic and wild animals and has a wide geographical distribution. It is mechanically transmitted mainly by haematophagous flies. Parasitological techniques are commonly used for the diagnosis of surra but have limited sensitivity. Therefore, serodiagnosis based on the detection of T. evansi specific antibodies is recommended by the World Organisation for Animal Health (OIE). Recently, we developed a new antibody detection test for the serodiagnosis of T. evansi infection, the Surra Sero K-SeT. Surra Sero K-SeT is an immunochromatographic test (ICT) that makes use of recombinant variant surface glycoprotein rVSG RoTat 1.2, produced in the yeast Pichia pastoris. In this study, we compared the diagnostic accuracy of the Surra Sero K-SeT and the Card Agglutination Test for T. evansi Trypanosomososis (CATT/T. evansi) with immune trypanolysis (TL) as reference test on a total of 806 sera from camels, water buffaloes, horses, bovines, sheep, dogs and alpacas. Test agreement was highest between Surra Sero K-SeT and TL (κ=0.91, 95% CI 0.841-0.979) and somewhat lower between CATT/T. evansi and TL (κ=0.85, 95% CI 0.785-0.922) and Surra Sero K-SeT and CATT/T. evansi (κ=0.81, 95% CI 0.742-0.878). The Surra Sero K-SeT displayed a somewhat lower overall specificity than CATT/T. evansi (94.8% versus 98.3%, χ(2)=13.37, p<0.001) but a considerably higher sensitivity (98.1% versus 84.4%, χ(2)=33.39, p<0.001). We conclude that the Surra Sero K-SeT may become an alternative for the CATT/T. evansi for sensitive detection of antibodies against T. evansi in domestic animals. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Lunar Water Resource Demonstration (LWRD) Test Results

    NASA Technical Reports Server (NTRS)

    Muscatello, Anthony C.; Captain, Janine E.; Quinn, Jacqueline W.; Gibson, Tracy L.; Perusich, Stephen A.; Weis, Kyle H.

    2009-01-01

    NASA has undertaken the In-Situ Resource Utilization (lSRU) project called RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction). This project is an Earth-based lunar precursor demonstration of a system that could be sent to explore permanently shadowed polar lunar craters, where it would drill into regolith, quantify the volatiles that are present, and extract oxygen by hydrogen reduction of iron oxides. The RESOLVE chemical processing system was mounted within the CMU rover "Scarab" and successfully demonstrated on Hawaii's Mauna Kea volcano in November 2008. This technology could be used on Mars as well. As described at the 2008 Mars Society Convention, the Lunar Water Resource Demonstration (LWRD) supports the objectives of the RESOLVE project by capturing and quantifying water and hydrogen released by regolith upon heating. Field test results for the quantification of water using LWRD showed that the volcanic ash (tephra) samples contained 0.15-0.41% water, in agreement with GC water measurements. Reduction of the RH in the surge tank to near zero during recirculation show that the water is captured by the water beds as desired. The water can be recovered by heating the Water Beds to 230 C or higher. Test results for the capture and quantification of pure hydrogen have shown that over 90% of the hydrogen can be captured and 98% of the absorbed hydrogen can be recovered upon heating the hydride to 400 C and desorbing the hydrogen several times into the evacuated surge tank. Thus, the essential requirement of capturing hydrogen and recovering it has been demonstrated. ,

  4. Correlation between thyroidal and peripheral blood total T cells, CD8+ T cells, and CD8+ T- regulatory cells and T-cell reactivity to calsequestrin and collagen XIII in patients with Graves' ophthalmopathy.

    PubMed

    Al-Ansari, Farah; Lahooti, Hooshang; Stokes, Leanne; Edirimanne, Senarath; Wall, Jack

    2018-05-22

    Purpose/aim of the study: Graves' ophthalmopathy (GO) is closely related to the thyroid autoimmune disorder Graves' disease. Previous studies have suggested roles for thyroidal CD8 +  T cells and autoimmunity against calsequestrin-1 (CASQ)-1 in the link between thyroidal and orbital autoimmune reactions in GO. A role for autoimmunity against CollXIII has also been suggested. In this study, we aimed to investigate correlations between some thyroidal and peripheral blood T-cell subsets and thyroidal T-cell reactivity against CASQ1 and CollXIII in patients with GO. Fresh thyroid tissues were processed by enzyme digestion and density gradient to isolate mononuclear cells (MNCs). Peripheral blood MNCs were also isolated using density gradient. Flow-cytometric analysis was used to identify the various T-cell subsets. T -cell reactivity to CASQ1 and CollXIII was measured by a 5-day culture of the MNCs and BrdU uptake method. We found a positive correlation between thyroidal CD8 +  T cells and CD8 +  T-regulatory (T-reg) cells in patients with GO. Thyroidal T cells from two out of the three patients with GO tested (66.7%) showed a positive response to CASQ1, while thyroidal T cells from none of the six Graves' Disease patients without ophthalmopathy (GD) tested showed a positive response to this antigen. Thyroidal T cells from these patient groups however, showed no significant differences in their response to CollXIII. Our observations provide further evidence for a possible role of thyroidal CD8 +  T cells, CD8 +  T-reg cells and the autoantigen CASQ1 in the link between thyroidal and orbital autoimmune reactions of GO.

  5. The tuberculin skin test increases the responses measured by T cell interferon-gamma release assays.

    PubMed

    Vilaplana, C; Ruiz-Manzano, J; Gil, O; Cuchillo, F; Montané, E; Singh, M; Spallek, R; Ausina, V; Cardona, P J

    2008-06-01

    RUTI is a vaccine consisting of Mycobacterium tuberculosis bacilli grown in stress conditions that is fragmented, detoxified and liposomed. RUTI was designed to shorten the treatment of latent tuberculosis infection (LTBI) with isoniazid from 9 months to just 1 month, by additional treatment with two inoculations of RUTI 4 weeks apart. During the validation process for monitoring the immunogenicity of administration of RUTI in a Phase I clinical trial, the question arose whether to introduce the tuberculin skin test (TST) in the screening of non-LTBI volunteers. This study was designed to evaluate the effect of TST on subsequent different T-cell interferon-gamma release assay (TIGRA) responses, using a spectrum of M. tuberculosis-related antigens (ESAT-6, CFP-10, 16 kDa, 19 kDa, MPT64, Ag 85B, 38 kDa, hsp65, PPD and BCG). The results showed an increase in post-TST response even in non-LTBI subjects for most antigens tested, as measured both by whole blood assay (WBA) and ELISPOT. Increased ELISPOT response decreased toward pre-TST levels within 1 month whereas the WBA response did not. Taking into account that there is no definitive correlation between TST and TIGRA tests to diagnose LTBI and the feasibility that TST might alter the immune monitoring included in clinical trials, these data suggest that TST determination should be carefully planned to avoid any interference with TIGRA.

  6. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    NASA Technical Reports Server (NTRS)

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  7. Five-Point Likert Items: t Test versus Mann-Whitney-Wilcoxon

    ERIC Educational Resources Information Center

    de Winter, Joost C. F.; Dodou, Dimitra

    2010-01-01

    Likert questionnaires are widely used in survey research, but it is unclear whether the item data should be investigated by means of parametric or nonparametric procedures. This study compared the Type I and II error rates of the "t" test versus the Mann-Whitney-Wilcoxon (MWW) for five-point Likert items. Fourteen population…

  8. Single Insulin-Specific CD8+ T Cells Show Characteristic Gene Expression Profiles in Human Type 1 Diabetes

    PubMed Central

    Luce, Sandrine; Lemonnier, François; Briand, Jean-Paul; Coste, Joel; Lahlou, Najiba; Muller, Sylviane; Larger, Etienne; Rocha, Benedita; Mallone, Roberto; Boitard, Christian

    2011-01-01

    OBJECTIVE Both the early steps and the high recurrence of autoimmunity once the disease is established are unexplained in human type 1 diabetes. Because CD8+ T cells are central and insulin is a key autoantigen in the disease process, our objective was to characterize HLA class I–restricted autoreactive CD8+ T cells specific for preproinsulin (PPI) in recent-onset and long-standing type 1 diabetic patients and healthy control subjects. RESEARCH DESIGN AND METHODS We used HLA-A*02:01 tetramers complexed to PPI peptides to enumerate circulating PPI-specific CD8+ T cells in patients and characterize them using membrane markers and single-cell PCR. RESULTS Most autoreactive CD8+ T cells detected in recent-onset type 1 diabetic patients are specific for leader sequence peptides, notably PPI6–14, whereas CD8+ T cells in long-standing patients recognize the B-chain peptide PPI33–42 (B9–18). Both CD8+ T-cell specificities are predominantly naïve, central, and effector memory cells, and their gene expression profile differs from cytomegalovirus-specific CD8+ T cells. PPI6–14–specific CD8+ T cells detected in one healthy control displayed Il-10 mRNA expression, which was not observed in diabetic patients. CONCLUSIONS PPI-specific CD8+ T cells in type 1 diabetic patients include central memory and target different epitopes in new-onset versus long-standing disease. Our data support the hypothesis that insulin therapy may contribute to the expansion of autoreactive CD8+ T cells in the long term. PMID:21998398

  9. 6. Exterior view of Components Test Laboratory (T27), looking southwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Exterior view of Components Test Laboratory (T-27), looking southwest. The building wing on the left houses Test Cell 9 (fuel), and that on the right houses the equipment room. The corrugated aluminum shed that is taller than the main building in the left foreground houses a citric acid air pollution control room (also known as scrubber room), the interior of which may be seen in CO-88-A-21. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  10. Experimental test results of a generalized parameter fuel control

    NASA Technical Reports Server (NTRS)

    Batterton, P. G.; Gold, H.

    1973-01-01

    Considerable interest has been generated recently in low cost jet propulsion systems. One of the more complicated components of jet engines is the fuel control. Results of an effort to develop a simpler hydromechanical fuel control are presented. This prototype fuel control was installed on a J85-GE-13 jet engine. Results show that the fuel control provided satisfactory engine performance at sea level static conditions over its normal nonafterburning operating range, including startup. Results of both bench and engine tests are presented; the difficulties encountered are described.

  11. Loss of PiT-1 Results in Abnormal Endocytosis in the Yolk Sac Visceral Endoderm

    PubMed Central

    Wallingford, Mary C.; Giachelli, Cecilia M.

    2014-01-01

    PiT-1 protein is a transmembrane sodium-dependent phosphate (Pi) transporter. PiT-1 knock out (KO) embryos die from largely unknown causes by embryonic day (E) 12.5. We tested the hypothesis that PiT-1 is required for endocytosis in the embryonic yolk sac (YS) visceral endoderm (VE). Here we present data supporting that PiT-1 KO results in a YS remodeling defect and decreased endocytosis in the YS VE. The remodeling defect is not due to an upstream cardiomyocyte requirement for PiT-1, as SM22αCre-specific KO of PiT-1 in the developing heart and the YS mesodermal layer (ME) does not recapitulate the PiT-1 global KO phenotype. Furthermore, we find that high levels of PiT-1 protein localize to the YS VE apical membrane. Together these data support that PiT-1 is likely required in YS VE. During normal development maternal immunoglobulin (IgG) is endocytosed into YS VE and accumulates in the apical side of the VE in a specialized lysosome termed the apical vacuole (AV). We have identified a reduction in PiT-1 KO VE cell height and a striking loss of IgG accumulation in the PiT-1 KO VE. The endocytosis genes Tfeb, Lamtor2 and Snx2 are increased at the RNA level. Lysotracker Red staining reveals a loss of distinct AVs, and yolk sacs incubated ex vivo with phRODO Green Dextran for Endocytosis demonstrate a functional loss of endocytosis. As yolk sac endocytosis is controlled in part by microautophagy, but expression of LC3 had not been examined, we investigated LC3 expression during yolk sac development and found stage-specific LC3 RNA expression that is predominantly from the YS VE layer at E9.5. Normalized LC3-II protein levels are decreased in the PiT-1 KO YS, supporting a requirement for PiT-1 in autophagy in the YS. Therefore, we propose the novel idea that PiT-1 is central to the regulation of endocytosis and autophagy in the YS VE. PMID:25138534

  12. Preoperative detection of malignant liver tumors: Comparison of 3D-T2-weighted sequences with T2-weighted turbo spin-echo and single shot T2 at 1.5 T.

    PubMed

    Barat, Maxime; Soyer, Philippe; Dautry, Raphael; Pocard, Marc; Lo-Dico, Rea; Najah, Haythem; Eveno, Clarisse; Cassinotto, Christophe; Dohan, Anthony

    2018-03-01

    To assess the performances of three-dimensional (3D)-T2-weighted sequences compared to standard T2-weighted turbo spin echo (T2-TSE), T2-half-Fourier acquisition single-shot turbo spin-echo (T2-HASTE), diffusion weighted imaging (DWI) and 3D-T1-weighted VIBE sequences in the preoperative detection of malignant liver tumors. From 2012 to 2015, all patients of our institution undergoing magnetic resonance imaging (MRI) examination for suspected malignant liver tumors were prospectively included. Patients had contrast-enhanced 3D-T1-weighted, DWI, 3D-T2-SPACE, T2-HASTE and T2-TSE sequences. Imaging findings were compared with those obtained at follow-up, surgery and histopathological analysis. Sensitivities for the detection of malignant liver tumors were compared for each sequence using McNemar test. A subgroup analysis was conducted for HCCs. Image artifacts were analyzed and compared using Wilcoxon paired signed rank-test. Thirty-three patients were included: 13 patients had 40 hepatocellular carcinomas (HCC) and 20 had 54 liver metastases. 3D-T2-weighted sequences had a higher sensitivity than T2-weighted TSE sequences for the detection of malignant liver tumors (79.8% versus 68.1%; P < 0.001). The difference did not reach significance for HCC. T1-weighted VIBE and DWI had a higher sensitivity than T2-weighted sequences. 3D-T2-weighted-SPACE sequences showed significantly less artifacts than T2-weitghted TSE. 3D-T2-weighted sequences show very promising performances for the detection of liver malignant tumors compared to T2-weighted TSE sequences. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. WEATHER ON OTHER WORLDS. II. SURVEY RESULTS: SPOTS ARE UBIQUITOUS ON L AND T DWARFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metchev, Stanimir A.; Heinze, Aren; Apai, Dániel

    2015-02-01

    We present results from the Weather on Other Worlds Spitzer Exploration Science program to investigate photometric variability in L and T dwarfs, usually attributed to patchy clouds. We surveyed 44 L3-T8 dwarfs, spanning a range of J – K{sub s} colors and surface gravities. We find that 14/23 (61%{sub −20%}{sup +17%}, 95% confidence) of our single L3-L9.5 dwarfs are variable with peak-to-peak amplitudes between 0.2% and 1.5%, and 5/16 (31%{sub −17%}{sup +25%}) of our single T0-T8 dwarfs are variable with amplitudes between 0.8% and 4.6%. After correcting for sensitivity, we find that 80%{sub −27%}{sup +20%} of L dwarfs vary bymore » ≥0.2%, and 36%{sub −17%}{sup +26%} of T dwarfs vary by ≥0.4%. Given viewing geometry considerations, we conclude that photospheric heterogeneities causing >0.2% 3-5 μm flux variations are present on virtually all L dwarfs, and probably on most T dwarfs. A third of L dwarf variables show irregular light curves, indicating that L dwarfs may have multiple spots that evolve over a single rotation. Also, approximately a third of the periodicities are on timescales >10 hr, suggesting that slowly rotating brown dwarfs may be common. We observe an increase in the maximum amplitudes over the entire spectral type range, revealing a potential for greater temperature contrasts in T dwarfs than in L dwarfs. We find a tentative association (92% confidence) between low surface gravity and high-amplitude variability among L3-L5.5 dwarfs. Although we can not confirm whether lower gravity is also correlated with a higher incidence of variables, the result is promising for the characterization of directly imaged young extrasolar planets through variability.« less

  14. Edge profiles and limiter tests in Extrap T2

    NASA Astrophysics Data System (ADS)

    Bergsåker, H.; Hedin, G.; Ilyinsky, L.; Larsson, D.; Möller, A.

    New edge profile measurements, including calorimetric measurements of the parallel heat flux, were made in Extrap T2. Test limiters of pure molybdenum and the TZM molybdenum alloy have been exposed in the edge plasma. The surface damage was studied, mainly by microscopy. Tungsten coated graphite probes were also exposed, and the surfaces were studied by microscopy, ion beam analysis and XPS. In this case cracking and mixing of carbon and tungsten at the interface was observed in the most heated areas, whereas carbide formation at the surface was seen in less heated areas. In these tests pure Mo generally fared better than TZM, and thin and cleaner coatings fared better than thicker and less clean.

  15. [Transcranial direct current stimulation (tDCS) for depression: Results of nearly a decade of clinical research].

    PubMed

    Palm, U; Ayache, S S; Padberg, F; Lefaucheur, J-P

    2016-02-01

    Since 2006 transcranial direct current stimulation (tDCS) has been investigated in the treatment of depression. In this review, we discuss the implications and clinical perspectives that tDCS may have as a therapeutic tool in depression from the results reported in this domain. A comprehensive literature review has found nearly thirty articles - all in English - on this topic, corresponding to clinical studies, placebo-controlled or not, case reports and reviews. Several meta-analyses showed that the antidepressant effects of active tDCS are significant against placebo, but variable, mainly due to the heterogeneity of the patients included in the studies, for example regarding the resistance to antidepressant treatment. Specific recommendations for the use of tDCS in treating depression may not yet be available, but some elements of good practice can be highlighted. Of particular note is that anodal tDCS of the left prefrontal cortex at 2mA for 20 minutes per day has a potential therapeutic value without risk of significant side effects: tDCS offers safe conditions for clinical use in the treatment of depression. Copyright © 2015 L’Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.

  16. Thermal decomposition of high-nitrogen energetic compounds: TAGzT and GUzT

    NASA Astrophysics Data System (ADS)

    Hayden, Heather F.

    The U.S. Navy is exploring high-nitrogen compounds as burning-rate additives to meet the growing demands of future high-performance gun systems. Two high-nitrogen compounds investigated as potential burning-rate additives are bis(triaminoguanidinium) 5,5-azobitetrazolate (TAGzT) and bis(guanidinium) 5,5'-azobitetrazolate (GUzT). Small-scale tests showed that formulations containing TAGzT exhibit significant increases in the burning rates of RDX-based gun propellants. However, when GUzT, a similarly structured molecule was incorporated into the formulation, there was essentially no effect on the burning rate of the propellant. Through the use of simultaneous thermogravimetric modulated beam mass spectrometry (STMBMS) and Fourier-Transform ion cyclotron resonance (FTICR) mass spectrometry methods, an investigation of the underlying chemical and physical processes that control the thermal decomposition behavior of TAGzT and GUzT alone and in the presence of RDX, was conducted. The objective was to determine why GUzT is not as good a burning-rate enhancer in RDX-based gun propellants as compared to TAGzT. The results show that TAGzT is an effective burning-rate modifier in the presence of RDX because the decomposition of TAGzT alters the initial stages of the decomposition of RDX. Hydrazine, formed in the decomposition of TAGzT, reacts faster with RDX than RDX can decompose itself. The reactions occur at temperatures below the melting point of RDX and thus the TAGzT decomposition products react with RDX in the gas phase. Although there is no hydrazine formed in the decomposition of GUzT, amines formed in the decomposition of GUzT react with aldehydes, formed in the decomposition of RDX, resulting in an increased reaction rate of RDX in the presence of GUzT. However, GUzT is not an effective burning-rate modifier because its decomposition does not alter the initial gas-phase decomposition of RDX. The decomposition of GUzT occurs at temperatures above the melting point

  17. 6. Exterior view, showing structural details and instrumentation at the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Exterior view, showing structural details and instrumentation at the walk-in entry level (bottom) of Test Cell 6, Systems Integration Laboratory Building (T-28), looking southwest. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. 7. Exterior view, showing instrumentation and gauge panel at the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Exterior view, showing instrumentation and gauge panel at the walk-in entry level (bottom) of Test Cell 6, Systems Integration Laboratory Building (T-28), looking west. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  19. 10. Exterior view, showing the structural details and tanks above ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Exterior view, showing the structural details and tanks above at walk-in entry level (bottom) of Test Cell 7, Systems Integration Laboratory Building (T-28), looking west. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  20. Lomnický štít Observatory - meteorology and solar astrophysics. (Slovak Title: Observatórium Lomnický štít - meteorológia a slnečná astrofyzika)

    NASA Astrophysics Data System (ADS)

    Rybák, J.; Mačura, R.; Bendík, P.; Bochníček, O.; Horecká, V.

    2010-12-01

    The paper presents statistical results obtained in the analysis of long-term series of meteorological observations of temperature, wind speed and wind direction, and daylight length that were measured in the period 1964-2009 at the SHMI Meteorological Observatory located at the Lomnický štít mountain peak. In relation to these meteorological data, the contribution also presents statistical results for time scales of various types of solar prominence and solar corona observations at the Lomnický štít Astronomical Observatory in the period 1980-2009. The obtained results were used to characterize the observatory from meteorological perspective presenting mainly the range and quality of observing conditions suitable for solar activity observations. The results show that observing conditions allow for observation of prominences in approximately one third of the days in a year, and observation of the emission corona in approximately one fifth of the days in a year. The contribution also documents the use of the obtained results in preparation of new post-focal instruments for solar corona monitoring, i. e. the coronal multipolarimeter (COMP-S) that is at present under construction. Effects of local warming of the Earth's atmosphere are tested in a statistical analysis of the meteorological data collected in the period 1964-2009. In this period, a marked local warming occured at Lomnický štít with increases in the minimal daily temperature 0.90°C and maximal daily temperature 1.84°C, and the mean value of these quantities raising by 1.21°C.

  1. Fan Noise Source Diagnostic Test: Tone Modal Structure Results

    NASA Technical Reports Server (NTRS)

    Heidelberg, Laurence J.

    2002-01-01

    This investigation is part of a test series that was extremely comprehensive and included aerodynamic and acoustic testing of a fan stage using two different fan rotors and three different stator designs. The test series is known as the Source Diagnostic Test (SDT) and was conducted by NASA Glenn as part of the Advanced Subsonic Technology (AST) Noise Reduction Program. Tone mode measurements of one of the rotors with three different stators were made. The stator designs involve changes in vane count and sweep at constant solidity. The results of both inlet and exhaust tone mode measurements are presented in terms of mode power for both circumferential and radial mode orders. The results show benefits of vane sweep to be large, up to 13 dB in total tone power. At many conditions, the increase in power due to cutting on the rotor/stator interaction is more than offset by vane sweep. The rotor locked mode is shown as an important contributor to tone power when the blade tip speed is near and above Mach one. This is most evident in the inlet when the direct rotor field starts to cut on.

  2. A Si/Glass Bulk-Micromachined Cryogenic Heat Exchanger for High Heat Loads: Fabrication, Test, and Application Results.

    PubMed

    Zhu, Weibin; White, Michael J; Nellis, Gregory F; Klein, Sanford A; Gianchandani, Yogesh B

    2010-02-01

    This paper reports on a micromachined Si/glass stack recuperative heat exchanger with in situ temperature sensors. Numerous high-conductivity silicon plates with integrated platinum resistance temperature detectors (Pt RTDs) are stacked, alternating with low-conductivity Pyrex spacers. The device has a 1 x 1-cm(2) footprint and a length of up to 3.5 cm. It is intended for use in Joule-Thomson (J-T) coolers and can sustain pressure exceeding 1 MPa. Tests at cold-end inlet temperatures of 237 K-252 K show that the heat exchanger effectiveness is 0.9 with 0.039-g/s helium mass flow rate. The integrated Pt RTDs present a linear response of 0.26%-0.30%/K over an operational range of 205 K-296 K but remain usable at lower temperatures. In self-cooling tests with ethane as the working fluid, a J-T system with the heat exchanger drops 76.1 K below the inlet temperature, achieving 218.7 K for a pressure of 835.8 kPa. The system reaches 200 K in transient state; further cooling is limited by impurities that freeze within the flow stream. In J-T self-cooling tests with an external heat load, the system reaches 239 K while providing 1 W of cooling. In all cases, there is an additional parasitic heat load estimated at 300-500 mW.

  3. Radiative, actively cooled panel tests results

    NASA Technical Reports Server (NTRS)

    Shore, C. P.; Nowak, R. J.; Sharpe, E. L.

    1978-01-01

    The radiative, actively cooled panel designed to withstand a uniform incident heat flux of 136 kW/sq m to a 444 K surface temperature was evaluated. The test program consisted of preliminary static thermal mechanical loading and aerothermal flow tests. Test results are briefly discussed.

  4. SCD1 thermal design and test result analysis

    NASA Technical Reports Server (NTRS)

    Cardoso, Humberto Pontes; Muraoka, Issamu; Mantelli, Marcia Barbosa Henriques; Leite, Rosangela M. G.

    1990-01-01

    The SCD 01 (Satelite de Coleta de Dados 01) is a spin stabilized low Earth orbit satellite dedicated to the collection and distribution of environmental data. It was completely developed at the Brazilian Institute for Space Research (INPE) and is scheduled to be launched in 1992. The SCD 01 passive thermal control design configuration is presented and the thermal analysis results are compared with the temperatures obtained from a Thermal Balance Test. The correlation between the analytical and experimental results is considered very good. Numerical flight simulations show that the thermal control design can keep all the subsystem temperatures within their specified temperature range.

  5. Expression of Master Regulators of T-cell, Helper T-cell and Follicular Helper T-cell Differentiation in Angioimmunoblastic T-cell Lymphoma.

    PubMed

    Matsumoto, Yosuke; Nagoshi, Hisao; Yoshida, Mihoko; Kato, Seiichi; Kuroda, Junya; Shimura, Kazuho; Kaneko, Hiroto; Horiike, Shigeo; Nakamura, Shigeo; Taniwaki, Masafumi

    2017-11-01

    Objective It has been postulated that the normal counterpart of angioimmunoblastic T-cell lymphoma (AITL) is the follicular helper T-cell (TFH). Recent immunological studies have identified several transcription factors responsible for T-cell differentiation. The master regulators associated with T-cell, helper T-cell (Th), and TFH differentiation are reportedly BCL11B, Th-POK, and BCL6, respectively. We explored the postulated normal counterpart of AITL with respect to the expression of the master regulators of T-cell differentiation. Methods We performed an immunohistochemical analysis in 15 AITL patients to determine the expression of the master regulators and several surface markers associated with T-cell differentiation. Results BCL11B was detected in 10 patients (67%), and the surface marker of T-cells (CD3) was detected in all patients. Only 2 patients (13%) expressed the marker of naïve T-cells (CD45RA), but all patients expressed the marker of effector T-cells (CD45RO). Nine patients expressed Th-POK (60%), and 7 (47%) expressed a set of surface antigens of Th (CD4-positive and CD8-negative). In addition, BCL6 and the surface markers of TFH (CXCL13, PD-1, and SAP) were detected in 11 (73%), 8 (53%), 14 (93%), and all patients, respectively. Th-POK-positive/BCL6-negative patients showed a significantly shorter overall survival (OS) than the other patients (median OS: 33.0 months vs. 74.0 months, p=0.020; log-rank test). Conclusion Many of the AITL patients analyzed in this study expressed the master regulators of T-cell differentiation. The clarification of the diagnostic significance and pathophysiology based on the expression of these master regulators in AITL is expected in the future.

  6. Cytomegalovirus Reinfections Stimulate CD8 T-Memory Inflation.

    PubMed

    Trgovcich, Joanne; Kincaid, Michelle; Thomas, Alicia; Griessl, Marion; Zimmerman, Peter; Dwivedi, Varun; Bergdall, Valerie; Klenerman, Paul; Cook, Charles H

    2016-01-01

    Cytomegalovirus (CMV) has been shown to induce large populations of CD8 T-effector memory cells that unlike central memory persist in large quantities following infection, a phenomenon commonly termed "memory inflation". Although murine models to date have shown very large and persistent CMV-specific T-cell expansions following infection, there is considerable variability in CMV-specific T-memory responses in humans. Historically such memory inflation in humans has been assumed a consequence of reactivation events during the life of the host. Because basic information about CMV infection/re-infection and reactivation in immune competent humans is not available, we used a murine model to test how primary infection, reinfection, and reactivation stimuli influence memory inflation. We show that low titer infections induce "partial" memory inflation of both mCMV specific CD8 T-cells and antibody. We show further that reinfection with different strains can boost partial memory inflation. Finally, we show preliminary results suggesting that a single strong reactivation stimulus does not stimulate memory inflation. Altogether, our results suggest that while high titer primary infections can induce memory inflation, reinfections during the life of a host may be more important than previously appreciated.

  7. CD3+ICOS+ T cells show differences in the synthesis of nitric oxide, IFN-γ, and IL-10 in patients with pulmonary tuberculosis or in healthy household contacts.

    PubMed

    Lara-Rodríguez, Carmen; Alvarado-Vásquez, Noé; Bernal, Demetrio; Gorocica, Patricia; Zenteno, Edgar; Lascuraín, Ricardo

    2016-11-01

    Evidence indicates that more than 90 % of infected individuals never develop active tuberculosis. This fact highlights the relevance of the immune response in tuberculosis control. The inducible co-stimulator (ICOS) is a regulator of the function, differentiation, proliferation, and activation of T cells. Moreover, T cells synthesise nitric oxide (NO), interferon gamma (IFN-γ), and interleukin (IL)-10, which help regulate the immune response to tuberculosis. Therefore, we assessed the synthesis of NO, IFN-γ, and IL-10 in CD3 + ICOS + T cells from healthy individuals, household contacts (HHC), and patients with active pulmonary tuberculosis (PTB), previously stimulated with the antigen H37Rv. Our results indicated a significant increase in both the percentage of ICOS + cells and CD3 + ICOS + T cells producing NO, IFN-γ, and IL-10 in cells obtained from patients with PTB (p < 0.01). In addition, a high mitochondrial membrane potential (ΔΨ m ) in CD3 + ICOS + T cells was observed in the cells from HHC and from PTB patients, and is associated with the activation of T cells. In conclusion, results show that the CD3 + ICOS + T cells obtained from PTB patients are the main producers of NO, IFN-γ, and IL-10. In addition, our results imply that NO is a modulator of ICOS expression of T cells from PTB patients.

  8. Photocopy of original drawing showing Wing E (drawing located at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of original drawing showing Wing E (drawing located at NAWS China Lake, Division of Public Works). J.T. STAFFORD-J.H. DAVIES-H.L. GOGERTY: SICK OFFICERS QUARTERS, FLOOR PLAN AND ELEVATIONS - Naval Ordnance Test Station Inyokern, Dispensary, Main Site, Lauritsen Road at McIntyre Street, Ridgecrest, Kern County, CA

  9. High speed turboprops for executive aircraft, potential and recent test results

    NASA Technical Reports Server (NTRS)

    Mikkelson, D. C.; Mitchell, G. A.

    1980-01-01

    Four high speed propeller models were designed and tested in an 8x6 foot wind tunnel in order to evaluate the potential of advanced propeller technology. Results from these tests show that the combination of: increased blade number, aerodynamically integrated propeller/nacelles, reduced blade thickness, spinner area ruling, and blade sweep are important in achieving high propeller efficiency at the high cruise speeds.

  10. Test-to-Test Repeatability of Results From a Subsonic Wing-Body Configuration in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.; Pendergraft, Odis C., Jr.

    2000-01-01

    Results from three wind tunnel tests in the National Transonic Facility of a model of an advanced-technology, subsonic-transport wing-body configuration have been analyzed to assess the test-to-test repeatability of several aerodynamic parameters. The scatter, as measured by the prediction interval, in the longitudinal force and moment coefficients increases as the Mach number increases. Residual errors with and without the ESP tubes installed suggest a bias leading to lower drag with the tubes installed. Residual errors as well as average values of the longitudinal force and moment coefficients show that there are small bias errors between the different tests.

  11. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

    PubMed

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav; Manoliu, Andrei

    2017-01-01

    To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T.

  12. Ordering Molecular Genetic Tests and Reporting Results

    PubMed Central

    Lubin, Ira M.; Caggana, Michele; Constantin, Carolyn; Gross, Susan J.; Lyon, Elaine; Pagon, Roberta A.; Trotter, Tracy L.; Wilson, Jean Amos; McGovern, Margaret M.

    2008-01-01

    Previous studies have suggested that patient care may be compromised as a consequence of poor communication between clinicians and laboratory professionals in cases in which molecular genetic test results are reported. To understand better the contributing factors to such compromised care, we investigated both pre- and postanalytical processes using cystic fibrosis mutation analysis as our model. We found that although the majority of test requisition forms requested patient/family information that was necessary for the proper interpretation of test results, in many cases, these data were not provided by the individuals filling out the forms. We found instances in which result reports for simulated diagnostic testing described individuals as carriers where only a single mutation was found with no comment pertaining to a diagnosis of cystic fibrosis. Similarly, reports based on simulated scenarios for carrier testing were problematic when no mutations were identified, and the patient's race/ethnicity and family history were not discussed in reference to residual risk of disease. Remarkably, a pilot survey of obstetrician-gynecologists revealed that office staff, including secretaries, often helped order genetic tests and reported test results to patients, raising questions about what efforts are undertaken to ensure personnel competency. These findings are reviewed in light of what efforts should be taken to improve the quality of test-ordering and result-reporting practices. PMID:18669879

  13. High-throughput olfactory conditioning and memory retention test show variation in Nasonia parasitic wasps

    PubMed Central

    Hoedjes, K M; Steidle, J L M; Werren, J H; Vet, L E M; Smid, H M

    2012-01-01

    Most of our knowledge on learning and memory formation results from extensive studies on a small number of animal species. Although features and cellular pathways of learning and memory are highly similar in this diverse group of species, there are also subtle differences. Closely related species of parasitic wasps display substantial variation in memory dynamics and can be instrumental to understanding both the adaptive benefit of and mechanisms underlying this variation. Parasitic wasps of the genus Nasonia offer excellent opportunities for multidisciplinary research on this topic. Genetic and genomic resources available for Nasonia are unrivaled among parasitic wasps, providing tools for genetic dissection of mechanisms that cause differences in learning. This study presents a robust, high-throughput method for olfactory conditioning of Nasonia using a host encounter as reward. A T-maze olfactometer facilitates high-throughput memory retention testing and employs standardized odors of equal detectability, as quantified by electroantennogram recordings. Using this setup, differences in memory retention between Nasonia species were shown. In both Nasonia vitripennis and Nasonia longicornis, memory was observed up to at least 5 days after a single conditioning trial, whereas Nasonia giraulti lost its memory after 2 days. This difference in learning may be an adaptation to species-specific differences in ecological factors, for example, host preference. The high-throughput methods for conditioning and memory retention testing are essential tools to study both ultimate and proximate factors that cause variation in learning and memory formation in Nasonia and other parasitic wasp species. PMID:22804968

  14. T-kininogen can either induce or inhibit proliferation in Balb/c 3T3 fibroblasts, depending on the route of administration.

    PubMed

    Aravena, M; Pérez, C; Pérez, V; Acuña-Castillo, C; Gómez, C; Leiva-Salcedo, E; Nishimura, S; Sabaj, V; Walter, R; Sierra, F

    2005-03-01

    T-kininogen (T-KG) is a precursor of T-kinin, the most abundant kinin in rat serum, and also acts as a strong and specific cysteine proteinase inhibitor. Its expression is strongly induced during aging in rats, and expression of T-KG in Balb/c 3T3 fibroblasts results in inhibition of cell proliferation. However, T-KG is a serum protein produced primarily in the liver, and thus, most cells are only exposed to the protein from the outside. To test the effect of T-KG on fibroblasts exposed to exogenous T-KG, we purified the protein from the serum of K-kininogen-deficient Katholiek rats. In contrast to the results obtained by transfection, exposure of Balb/c 3T3 fibroblasts to exogenously added T-KG leads to a dose-dependent increase in [3H]-thymidine incorporation. This response does not require kinin receptors, but it is clearly mediated by activation of the ERK pathway. As a control, we repeated the transfection experiments, using a different promoter. The results are consistent with our published data showing that, under these circumstances, T-KG inhibits cell proliferation. We conclude that T-KG exerts opposite effects on fibroblast proliferation, depending exclusively on the way that it is administered to the cells (transfection versus exogenous addition).

  15. 'Test n Treat (TnT)'- Rapid testing and same-day, on-site treatment to reduce rates of chlamydia in sexually active further education college students: study protocol for a cluster randomised feasibility trial.

    PubMed

    Kerry-Barnard, Sarah; Fleming, Charlotte; Reid, Fiona; Phillips, Rachel; Drennan, Vari M; Adams, Elisabeth J; Majewska, Wendy; Balendra, Anjella; Harding-Esch, Emma; Cousins, Emma; Tariq Sadiq, S; Oakeshott, Pippa

    2018-06-05

    Sexually active young people attending London further education (FE) colleges have high rates of chlamydia, but screening rates are low. We will conduct a cluster randomised feasibility trial of frequent, rapid, on-site chlamydia testing and same-day treatment (Test and Treat (TnT)) in six FE colleges (with parallel qualitative and economic assessments) to assess the feasibility of conducting a future trial to investigate if TnT reduces chlamydia rates. We will recruit 80 sexually active students aged 16-24 years from public areas at each of six colleges. All participants (total n = 480) will be asked to provide samples (urine for males, self-taken vaginal swabs for females) and complete questionnaires on sexual lifestyle and healthcare use at baseline and after 7 months. Participants will be informed that baseline samples will not be tested for 7 months and be advised to get screened separately. Colleges will be randomly allocated to the intervention (TnT) or the control group (no TnT). One and 4 months after recruitment, participants at each intervention college (n = 3) will be texted and invited for on-site chlamydia tests using the 90-min Cepheid GeneXpert system. Students with positive results will be asked to see a visiting nurse health adviser for same-day treatment and partner notification, (backed by genitourinary medicine follow-up). Participants in control colleges (n = 3) will receive 'thank you' texts 1 and 4 months after recruitment. Seven months after recruitment, participants from both groups will be invited to complete questionnaires and provide samples for TnT. All samples will be tested, and same-day treatment offered to students with positive results. Acceptability of TnT will be assessed by qualitative interviews of purposively sampled students (n = 30) and college staff (n = 12). We will collect data on costs of TnT and usual healthcare. Findings will provide key values to inform feasibility, sample size and timescales of a

  16. Photocopy of original drawing showing Building 3 layout (drawing located ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of original drawing showing Building 3 layout (drawing located at NAWS China Lake, Division of Public Works). J.T. STAFFORD-J.H. DAVIES-H.L. GOGERTY: DISPENSARY, CONNECTING CORRIDORS, FLOOR PLAN, ELEVATIONS, AND DETAILS - Naval Ordnance Test Station Inyokern, Dispensary, Main Site, Lauritsen Road at McIntyre Street, Ridgecrest, Kern County, CA

  17. Photocopy of original drawing showing Wing A (drawing located at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of original drawing showing Wing A (drawing located at NAWS China Lake, Division of Public Works). J.T. STAFFORD-J.H. DAVIES- H.L. GOGERTY: DISPENSARY, SICK CALL AND ADMINISTRATION, FLOOR PLAN AND ELEVATIONS - Naval Ordnance Test Station Inyokern, Dispensary, Main Site, Lauritsen Road at McIntyre Street, Ridgecrest, Kern County, CA

  18. Photocopy of original drawing showing Wing B (drawing located at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of original drawing showing Wing B (drawing located at NAWS China Lake, Division of Public Works). J.T. STAFFORD-J.H. DAVIES-H.L. GOGERTY: DISPENSARY, SURGICAL AND OBSTETRICAL, FLOOR PLAN AND ELEVATIONS - Naval Ordnance Test Station Inyokern, Dispensary, Main Site, Lauritsen Road at McIntyre Street, Ridgecrest, Kern County, CA

  19. Infrared suppressor effect on T63 turboshaft engine performance

    NASA Technical Reports Server (NTRS)

    Bailey, E. E.; Civinskas, K. C.; Walker, C. L.

    1978-01-01

    Tests were conducted to determine if there are performance penalties associated with the installation of infrared (IR) suppressors on the T63-A-700 turboshaft engine. The testing was done in a sea-level, static test cell. The same engine (A-E402808 B) was run with the standard OH-58 aircraft exhaust stacks and with the ejector-type IR suppressors in order to make a valid comparison. Repeatability of the test results for the two configurations was verified by rerunning the conditions over a period of days. Test results showed no measurable difference in performance between the standard exhaust stacks and the IR suppressors.

  20. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    PubMed Central

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  1. Gun shows and gun violence: fatally flawed study yields misleading results.

    PubMed

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  2. Rockwell-Rocketdyne flywheel test results

    NASA Astrophysics Data System (ADS)

    Steele, R. S., Jr.; Babelay, E. F., Jr.; Sutton, B. J.

    1981-01-01

    Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during the testing.

  3. Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    PubMed

    Fischer, Anja; Kraff, Oliver; Orzada, Stephan; Nensa, Felix; Schäfer, Lena C; Ladd, Mark E; Umutlu, Lale; Lauenstein, Thomas C

    2014-05-01

    The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2-weighted turbo-spin-echo sequence, T1-w volume-interpolated breath-hold examination (VIBE), and fast low-angle shot (FLASH) with inversion recovery (IR) were acquired in coronal orientation. For dynamic imaging, gadoxetic acid was administrated and data were collected for a period of 5 to 40 minutes after injection. The volunteers underwent subsequent T2-w respiratory-gated MRC at 3 T. For qualitative analysis, a 5-point scale was used. Contrast ratios (CRs) were calculated for quantitative assessment. Contrast-enhanced T1-w MRC at 7 T showed a homogeneous depiction of the intrahepatic and extrahepatic biliary tract with a maximum enhancement of 20 minutes after contrast. Volume-interpolated breath-hold examination and FLASH IR provided a good image quality for the intrahepatic (VIBE, 3.60; FLASH IR, 3.67) and extrahepatic bile ducts (VIBE, 3.50; FLASH IR, 3.72). The quantitative analysis revealed high CR values for FLASH IR (intrahepatic CR, 0.41; extrahepatic CR, 0.45) because of an effective suppression of hepatic tissue and vessels. The T2-w TSE at 7 T showed only a poor image quality without diagnostic potential (intrahepatic, 2.22; extrahepatic, 1.93). Seven-tesla VIBE and FLASH revealed superiority in the depiction of the intrahepatic bile ducts, whereas 3-T MRC was superior in the delineation of the extrahepatic biliary tract. Our results demonstrate the feasibility of contrast-enhanced imaging of the biliary ducts at 7 T.

  4. A method for predicting the fatigue life of pre-corroded 2024-T3 aluminum from breaking load tests

    NASA Astrophysics Data System (ADS)

    Gruenberg, Karl Martin

    Characterization of material properties is necessary for design purposes and has been a topic of research for many years. Over the last several decades, much progress has been made in identifying metrics to describe fracture mechanics properties and developing procedures to measure the appropriate values. However, in the context of design, there has not been as much success in quantifying the susceptibility of a material to corrosion damage and its subsequent impact on material behavior in the framework of fracture mechanics. A natural next step in understanding the effects of corrosion damage was to develop a link between standard material test procedures and fatigue life in the presence of corrosion. Simply stated, the goal of this investigation was to formulate a cheaper and quicker method for assessing the consequences of corrosion on remaining fatigue life. For this study, breaking load specimens and fatigue specimens of a single nominal gage (0.063″) of aluminum alloy 2024-T3 were exposed to three levels of corrosion. The breaking load specimens were taken from three different material lots, and the fatigue tests were carried out at three stress levels. All failed specimens, both breaking load and fatigue specimens, were examined to characterize the damage state(s) and failure mechanism(s). Correlations between breaking load results and fatigue life results in the presence of corrosion damage were developed using a fracture mechanics foundation and the observed mechanisms of failure. Where breaking load tests showed a decrease in strength due to increased corrosion exposure, the corresponding set of fatigue tests showed a decrease in life. And where breaking load tests from different specimen orientations exhibited similar levels of strength, the corresponding set of fatigue specimens showed similar lives. The spread from shortest to longest fatigue lives among the different corrosion conditions decreased at the higher stress levels. Life predictions based

  5. Transgenic Expression of IL15 Improves Antiglioma Activity of IL13Rα2-CAR T Cells but Results in Antigen Loss Variants.

    PubMed

    Krenciute, Giedre; Prinzing, Brooke L; Yi, Zhongzhen; Wu, Meng-Fen; Liu, Hao; Dotti, Gianpietro; Balyasnikova, Irina V; Gottschalk, Stephen

    2017-07-01

    Glioblastoma (GBM) is the most aggressive primary brain tumor in adults and is virtually incurable with conventional therapies. Immunotherapy with T cells expressing GBM-specific chimeric antigen receptors (CAR) is an attractive approach to improve outcomes. Although CAR T cells targeting GBM antigens, such as IL13 receptor subunit α2 (IL13Rα2), HER2, and EGFR variant III (EGFRvIII), have had antitumor activity in preclinical models, early-phase clinical testing has demonstrated limited antiglioma activity. Transgenic expression of IL15 is an appealing strategy to enhance CAR T-cell effector function. We tested this approach in our IL13Rα2-positive glioma model in which limited IL13Rα2-CAR T-cell persistence results in recurrence of antigen-positive gliomas. T cells were genetically modified with retroviral vectors encoding IL13Rα2-CARs or IL15 (IL13Rα2-CAR.IL15 T cells). IL13Rα2-CAR.IL15 T cells recognized glioma cells in an antigen-dependent fashion, had greater proliferative capacity, and produced more cytokines after repeated stimulations in comparison with IL13Rα2-CAR T cells. No autonomous IL13Rα2-CAR.IL15 T-cell proliferation was observed; however, IL15 expression increased IL13Rα2-CAR T-cell viability in the absence of exogenous cytokines or antigen. In vivo , IL13Rα2-CAR.IL15 T cells persisted longer and had greater antiglioma activity than IL13Rα2-CAR T cells, resulting in a survival advantage. Gliomas recurring after 40 days after T-cell injection had downregulated IL13Rα2 expression, indicating that antigen loss variants occur in the setting of improved T-cell persistence. Thus, CAR T cells for GBM should not only be genetically modified to improve their proliferation and persistence, but also to target multiple antigens. Summary: Glioblastoma responds imperfectly to immunotherapy. Transgenic expression of IL15 in T cells expressing CARs improved their proliferative capacity, persistence, and cytokine production. The emergence of antigen

  6. Photocopy of original drawing showing Wing A (drawing located at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of original drawing showing Wing A (drawing located at NAWS China Lake, Division of Public Works). J.T. STAFFORD-J.H. DAVIES-H.L. GOGERTY: DISPENSARY, SICK CALL AND ADMINISTRATION, ROOF FRAMING PLAN AND DETAILS - Naval Ordnance Test Station Inyokern, Dispensary, Main Site, Lauritsen Road at McIntyre Street, Ridgecrest, Kern County, CA

  7. BK virus-specific T cells for use in cellular therapy show specificity to multiple antigens and polyfunctional cytokine responses.

    PubMed

    Blyth, Emily; Clancy, Leighton; Simms, Renee; Gaundar, Shivashni; O'Connell, Philip; Micklethwaite, Kenneth; Gottlieb, David J

    2011-11-27

    BK virus (BKV) infection causes hemorrhagic cystitis posthemopoietic stem-cell transplant and graft loss in renal transplant recipients. Reactivation occurs in up to 60% of patients in both groups. Treatment-related cellular immunosuppression is a major contributor to the development of BKV-related disease, but the targets of the immune response are not well characterized. Immunotherapy by adoptive transfer of cellular effectors has been shown to be effective in controlling and preventing some virus-related diseases in transplant recipients, particularly Epstein-Barr virus and cytomegalovirus. Infusion of BKV-specific T cells may potentially reconstitute functional BKV immunity and reduce clinical complications of BKV infection. BKV-specific T cells for clinical use in adoptive immunotherapy were generated using monocyte-derived dendritic cells pulsed with overlapping peptide mixes spanning the five BKV proteins VP1, VP2, VP3, large T antigen, and small T antigen. Phenotypic and functional characteristics of the cells were investigated as well as their antigen specificity. Expanded CD4(+) and CD8(+) cells responded to restimulation with BKV peptides principally from VP1, large T, or small T antigens; produced multiple cytokines; and showed cytotoxic activity against antigen-coated targets. Possible clinical uses for BKV-specific T cells generated using this method include immune reconstitution posthemopoietic stem-cell transplantation or prophylaxis and treatment of immune deficiency in renal transplant recipients, fulfilling the need for effective therapy for BKV-related hemorrhagic cystitis and renal dysfunction.

  8. Review of aquifer test results for the Lansdale area, Montgomery County, Pennsylvania, 1980-95

    USGS Publications Warehouse

    Goode, Daniel J.; Senior, Lisa A.

    1998-01-01

    Aquifer and aquifer-isolation test results in and around North Penn Area 6 Superfund site, Lansdale, Montgomery County, Pennsylvania are reviewed to provide estimated aquifer properties for use in a numerical model of ground-water flow. This review is in support of remedial action investigations by U.S. Environmental Protection Agency (USEPA), Region III, Philadelphia. Data are from files of the U.S. Geological Survey, USEPA, and water companies, and from unpublished consultant reports for USEPA and corporations in the Lansdale area. Tested wells are in fractured sedimentary rocks of the Brunswick Formation, which are Triassic-aged, dipping shales and sandstones. Review procedures include, in some cases, new analyses of drawdown during pumping and recovery using analytical models of flow to wells. Estimated aquifer transmissivities (T) range from zero to about 1,300 m2/d (meters squared per day), with most tests indicating T between 10 and 100 m2/d. Aquifer-isolation testing results indicate that most flow enters wells at a few discrete zones, probably fractures or bedding plane openings. The vertical connection between the zones in a single borehole with multiple producing zones often is negligible. This suggests that the formation is vertically anisotropic; the hydraulic conductivity is much larger in the horizontal direction than in the vertical direction. Some evidence of well-field-scale horizontal anisotropy exists, with maximum transmissivity aligned with the regional northeast strike of bedding, but this evidence is weak because of the small number of observation wells, particularly wells screened in isolated depth intervals. Analysis of recovery data after constant-pumping-rate aquifer tests and of drawdown during step tests suggests that a significant fraction, perhaps as much as 85 percent, of the drawdown in some production wells is due to well loss or skin effects in or very near the pumped well and is not caused by resistance to flow in the

  9. A Si/Glass Bulk-Micromachined Cryogenic Heat Exchanger for High Heat Loads: Fabrication, Test, and Application Results

    PubMed Central

    Zhu, Weibin; White, Michael J.; Nellis, Gregory F.; Klein, Sanford A.; Gianchandani, Yogesh B.

    2010-01-01

    This paper reports on a micromachined Si/glass stack recuperative heat exchanger with in situ temperature sensors. Numerous high-conductivity silicon plates with integrated platinum resistance temperature detectors (Pt RTDs) are stacked, alternating with low-conductivity Pyrex spacers. The device has a 1 × 1-cm2 footprint and a length of up to 3.5 cm. It is intended for use in Joule–Thomson (J–T) coolers and can sustain pressure exceeding 1 MPa. Tests at cold-end inlet temperatures of 237 K–252 K show that the heat exchanger effectiveness is 0.9 with 0.039-g/s helium mass flow rate. The integrated Pt RTDs present a linear response of 0.26%–0.30%/K over an operational range of 205 K–296 K but remain usable at lower temperatures. In self-cooling tests with ethane as the working fluid, a J–T system with the heat exchanger drops 76.1 K below the inlet temperature, achieving 218.7 K for a pressure of 835.8 kPa. The system reaches 200 K in transient state; further cooling is limited by impurities that freeze within the flow stream. In J–T self-cooling tests with an external heat load, the system reaches 239 K while providing 1 W of cooling. In all cases, there is an additional parasitic heat load estimated at 300–500 mW. PMID:20490284

  10. Honeywell Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  11. Rockwell-Rocketdyne flywheel test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, R.S. Jr.; Babelay, E.F. Jr.; Sutton, B.J.

    1981-01-01

    Results are presented of the spin test evaluation of the Rockwell-Rocketdyne RPE-10 design flywheel at the Oak Ridge Flywheel Evaluation Laboratory. Details of the static evaluation, including measures of weight, inertia, natural frequencies, and radiography, are also presented. The flywheel was subjected to seven spin cycles with a maximum of 383 rps, 105% of design speed. At that speed, the energy stored was 1.94 kWhr at 36.1 Whr/kg. The maximum speed was limited by the inability of the test facility to accommodate the increasing eccentric shift of both hub disks with increasing speed. No material degradation was observed during themore » testing.« less

  12. Working memory capacity differentially influences responses to tDCS and HD-tDCS in a retro-cue task.

    PubMed

    Gözenman, Filiz; Berryhill, Marian E

    2016-08-26

    There is growing interest in non-invasive brain stimulation techniques. A drawback is that the relationship between stimulation and cognitive outcomes for various tasks are unknown. Transcranial direct current stimulation (tDCS) provides diffuse current spread, whereas high-definition tDCS (HD-tDCS) provides more targeted current. The direction of behavioral effects after tDCS can be difficult to predict in cognitive realms such as attention and working memory (WM). Previously, we showed that in low and high WM capacity groups tDCS modulates performance in nearly equal and opposite directions on a change detection task, with improvement for the high capacity participants alone. Here, we used the retro-cue paradigm to test attentional shifting among items in WM to investigate whether WM capacity (WMC) predicted different behavioral consequences during anodal tDCS or HD-tDCS to posterior parietal cortex (PPC). In two experiments, with 24 participants each, we used different stimulus categories (colored circles, letters) and stimulation sites (right, left PPC). The results showed a significant (Experiment 1) or trending (Experiment 2) WMC x stimulation interaction. Compared to tDCS, after HD-tDCS the retro-cueing benefit was significantly greater for the low WMC group but numerically worse for the high WMC group. These data highlight the importance of considering group differences when using non-invasive neurostimulation techniques. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. To Show or Not to Show: The Effects of Item Stems and Answer Options on Performance on a Multiple-Choice Listening Comprehension Test

    ERIC Educational Resources Information Center

    Yanagawa, Kozo; Green, Anthony

    2008-01-01

    The purpose of this study is to examine whether the choice between three multiple-choice listening comprehension test formats results in any difference in listening comprehension test performance. The three formats entail (a) allowing test takers to preview both the question stem and answer options prior to listening; (b) allowing test takers to…

  14. Congenital hypothyroidism in a kitten resulting in decreased IGF-I concentration and abnormal liver function tests.

    PubMed

    Quante, Saskia; Fracassi, Federico; Gorgas, Daniela; Kircher, Patrick R; Boretti, Felicitas S; Ohlerth, Stefanie; Reusch, Claudia E

    2010-06-01

    A 7-month-old male kitten was presented with chronic constipation and retarded growth. Clinical examination revealed disproportional dwarfism with mild skeletal abnormalities and a palpable thyroid gland. The presumptive diagnosis of congenital hypothyroidism was confirmed by low serum total thyroxine (tT(4)) concentration prior to and after the administration of thyroid stimulation hormone (TSH), increased endogenous TSH concentration and abnormal thyroid scintigraphic scan. The kitten had abnormal liver function tests and decreased insulin-like growth factor 1 (IGF-1) concentration, both of which returned to normal in correspondence with an improvement of the clinical signs after 6 weeks of thyroxine therapy. Congenital hypothyroidism is a rare disease that may present with considerable variation in clinical manifestation. In cases in which clinical signs are ambiguous, disorders such as portosystemic shunt and hyposomatotropism have to be taken into account as differential diagnosis. As hypothyroidism may be associated with abnormal liver function tests and low IGF-1 concentrations, test results have to be interpreted carefully. Copyright 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

  15. Results of steel containment vessel model test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed bymore » the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed.« less

  16. Selective resistance of CD44hi T cells to p53-dependent cell death results in persistence of immunologic memory after total body irradiation.

    PubMed

    Yao, Zhenyu; Jones, Jennifer; Kohrt, Holbrook; Strober, Samuel

    2011-10-15

    Our previous studies showed that treatment of mice with total body irradiation (TBI) or total lymphoid tissue irradiation markedly changes the balance of residual T cell subsets to favor CD4(+)CD44(hi) NKT cells because of the differential resistance of the latter subset to cell death. The object of the current study was to further elucidate the changed balance and mechanisms of differential radioresistance of T cell subsets after graded doses of TBI. The experimental results showed that CD4(+) T cells were markedly more resistant than CD8(+) T cells, and CD44(hi) T cells, including NKT cells and memory T cells, were markedly more resistant than CD44(lo) (naive) T cells. The memory T cells immunized to alloantigens persisted even after myeloablative (1000 cGy) TBI and were able to prevent engraftment of bone marrow transplants. Although T cell death after 1000 cGy was prevented in p53(-/-) mice, there was progressive T cell death in p53(-/-) mice at higher doses. Although p53-dependent T cell death changed the balance of subsets, p53-independent T cell death did not. In conclusion, resistance of CD44(hi) T cells to p53-dependent cell death results in the persistence of immunological memory after TBI and can explain the immune-mediated rejection of marrow transplants in sensitized recipients.

  17. Assessing Perceptions AbouT Hazardous Substances (PATHS): The PATHS questionnaire

    PubMed Central

    Amlôt, Richard; Page, Lisa; Pearce, Julia; Wessely, Simon

    2013-01-01

    How people perceive the nature of a hazardous substance may determine how they respond when potentially exposed to it. We tested a new Perceptions AbouT Hazardous Substances (PATHS) questionnaire. In Study 1 (N = 21), we assessed the face validity of items concerning perceptions about eight properties of a hazardous substance. In Study 2 (N = 2030), we tested the factor structure, reliability and validity of the PATHS questionnaire across four qualitatively different substances. In Study 3 (N = 760), we tested the impact of information provision on Perceptions AbouT Hazardous Substances scores. Our results showed that our eight measures demonstrated good reliability and validity when used for non-contagious hazards. PMID:23104995

  18. Effects of vigorous mixing of blood vacuum tubes on laboratory test results.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Gelati, Matteo; Volanski, Waldemar; Boritiza, Katia Cristina; Picheth, Geraldo; Guidi, Gian Cesare

    2013-02-01

    To evaluate the effect of tubes mixing (gentle vs. vigorous) on diagnostic blood specimens collected in vacuum tube systems by venipuncture. Blood was collected for routine coagulation, immunochemistry and hematological testing from one hundred volunteers into six vacuum tubes: two 3.6 mL vacuum tubes containing 0.4 mL of buffered sodium citrate (9NC) 0.109 mol/L: 3.2 W/V%; two 3.5 mL vacuum tubes with clot activator and gel separator; and two 3.0 mL vacuum tubes containing 5.9 mg K(2)EDTA (Terumo Europe, Belgium). Immediately after the venipuncture all vacuum tubes (each of one additive type) were processed through two different procedures: i) Standard: blood specimens in K(2)EDTA- or sodium citrate-vacuum tubes were gently inverted five times whereas the specimens in tubes with clot activator and gel separator were gently inverted ten times, as recommended by the manufacturer; ii) Vigorous mix: all blood specimens were shaken up vigorously during 3-5s independently of the additive type inside the tubes. The significance of the differences between samples was assessed by Student's t-test or Wilcoxon ranked-pairs test after checking for normality. The level of statistical significance was set at P<0.05. No significant difference (P<0.05) was detected between the procedures for all tested parameters. Surprisingly only a visual alteration (presence of foam on the top) was shown by all the tubes mixed vigorously before centrifugation (Fig. 1 A, B and C). Moreover the serum tubes from vigorous mixing procedure shows a "blood ring" on the tube top after stopper removal (Fig. 1 D). Our results drop out a paradigm suggesting that the incorrect primary blood tubes mixing promotes laboratory variability. We suggest that similar evaluation should be done using other brands of vacuum tubes by each laboratory manager. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Results of EVA/mobile transporter space station truss assembly tests

    NASA Technical Reports Server (NTRS)

    Watson, Judith J.; Heard, Walter L., Jr.; Bush, Harold G.; Lake, M. S.; Jensen, J. K.; Wallsom, R. E.; Phelps, J. E.

    1988-01-01

    Underwater neutral buoyance tests were conducted to evaluate the use of a Mobile Transporter concept in conjunction with EVA astronauts to construct the Space Station Freedom truss structure. A three-bay orthogonal tetrahedral truss configuration with a 15 foot square cross section was repeatedly assembled by a single pair of pressure suited test subjects working from the Mobile Transporter astronaut positioning devices (mobile foot restraints). The average unit assembly time (which included integrated installation of utility trays) was 27.6 s/strut, or 6 min/bay. The results of these tests indicate that EVA assembly of space station size structures can be significantly enhanced when using a Mobile Transporter equipped with astronaut positioning devices. Rapid assembly time can be expected and are dependent primarily on the rate of translation permissible for on-orbit operations. The concept used to demonstate integrated installation of utility trays requires minimal EVA handling and consequentially, as the results show, has little impact on overall assembly time.

  20. (Updated) Targeted T-Cell Therapy Shows Promise Against Triple-Negative Breast Cancer | Poster

    Cancer.gov

    (Updated May 8) A study led by the Baylor College of Medicine and supported by NCI’s Center for Cancer Research (CCR) has demonstrated that chimeric antigen receptor (CAR) T-cell therapy can be used to treat solid triple-negative breast cancer (TNBC) tumors. The investigation is the first work using CAR T-cell therapy against TEM8, a cell surface protein that is frequently

  1. The Effect of Artificial Aging on the Tensile Properties of Alclad 24S-T and 24S-T Aluminum Alloy

    NASA Technical Reports Server (NTRS)

    Kotanchik, Joseph N.; Woods, Walter; Zender, George W.

    1943-01-01

    An experimental study was made to determine the effect of artificial aging on the tensile properties of alclad 24S-T and 24S-T aluminum-alloy sheet material. The results of the tests show that certain combinations of aging time and temperature cause a marked increase in the yield strength and a small increase in the ultimate strength; these increases are accompanied by a very large decrease in elongation. A curve is presented that shows the maximum yield strengths that can be obtained by aging this material at various combinations of time and temperature. The higher values of yield stress are obtained in material aged at relatively longer times and lower temperatures.

  2. Application of Bionic Design to FRP T-Joints

    NASA Astrophysics Data System (ADS)

    Luo, Guang-Min; Kuo, Chia-Hung

    2017-09-01

    We applied the concepts of bionics to enhance the mechanical strength of fiberglass reinforced plastic T-joints. The failure modes of the designed arthrosis-like and gum-like joints were determined using three-point bending tests and numerical simulations and compared with those of normal T-joints bonded using structural adhesives. In the simulation, we used cohesive elements to simulate the adhesive interface of the structural adhesive. The experimental and simulation results show that the arthrosis-like joint can effectively delay the failure progress and enhance the bonding strength of T-joints, thus confirming that an appropriate bionic design can effectively control the bonding properties of structural adhesives.

  3. A Multiple Aminoacyl-tRNA Synthetase Complex That Enhances tRNA-Aminoacylation in African Trypanosomes

    PubMed Central

    Cestari, Igor; Kalidas, Savitha; Monnerat, Severine; Anupama, Atashi; Phillips, Margaret A.

    2013-01-01

    The genes for all cytoplasmic and potentially all mitochondrial aminoacyl-tRNA synthetases (aaRSs) were identified, and all those tested by RNA interference were found to be essential for the growth of Trypanosoma brucei. Some of these enzymes were localized to the cytoplasm or mitochondrion, but most were dually localized to both cellular compartments. Cytoplasmic T. brucei aaRSs were organized in a multiprotein complex in both bloodstream and procyclic forms. The multiple aminoacyl-tRNA synthetase (MARS) complex contained at least six aaRS enzymes and three additional non-aaRS proteins. Steady-state kinetic studies showed that association in the MARS complex enhances tRNA-aminoacylation efficiency, which is in part dependent on a MARS complex-associated protein (MCP), named MCP2, that binds tRNAs and increases their aminoacylation by the complex. Conditional repression of MCP2 in T. brucei bloodstream forms resulted in reduced parasite growth and infectivity in mice. Thus, association in a MARS complex enhances tRNA-aminoacylation and contributes to parasite fitness. The MARS complex may be part of a cellular regulatory system and a target for drug development. PMID:24126051

  4. A T0/Trigger detector for the External Target Experiment at CSR

    NASA Astrophysics Data System (ADS)

    Hu, D.; Shao, M.; Sun, Y.; Li, C.; Chen, H.; Tang, Z.; Zhang, Y.; Zhou, J.; Zeng, H.; Zhao, X.; You, W.; Song, G.; Deng, P.; Lu, J.; Zhao, L.

    2017-06-01

    A new T0/Trigger detector based on multi-gap resistive plate chamber (MRPC) technology has been constructed and tested for the external target experiment (ETE) at HIRFL-CSR. It measures the multiplicity and timing information of particles produced in heavy-ion collisions at the target region, providing necessary event collision time (T0) and collision centrality with high precision. Monte-Carlo simulation shows a time resolution of several tens of picosecond can be achieved at central collisions. The experimental tests have been performed for this prototype detector at the CSR-ETE. The preliminary results are shown to demonstrate the performance of the T0/Trigger detector.

  5. "I Don't Know" and Multiple Choice Analysis of Pre- and Post-Tests

    ERIC Educational Resources Information Center

    Spears, Karen; Wilson, Mary

    2010-01-01

    Evaluation is an essential component of any Extension education program. One tool, the pre- and post-test, provides measurable evaluation data. Yet often the answer "I don't know" or all possible answers to a multiple choice question are not included in the repeated measure analysis. Because more than two answers are offered, the test of marginal…

  6. Chemical compatibility screening test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) amore » mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.« less

  7. Deoxynivalenol, zearalenone and T-2 in grain based swine feed in Hungary.

    PubMed

    Tima, Helga; Rácz, Anita; Guld, Zsuzsanna; Mohácsi-Farkas, Csilla; Kiskó, Gabriella

    2016-12-01

    Fusarium genera can produce trichothecenes like deoxynivalenol (DON), zearalenone (ZEN) and T-2 toxin, which can occur in feed cereal grains. Enzyme-linked immunosorbent assays (ELISA) tests of different Hungarian swine feedstuff proved that these mycotoxins were present. In this survey, 45 feed samples from 3 significant Hungarian swine feedstuff manufacturers were tested. ELISA methodology validation showed mean recovery rates in ranges from 85.3% to 98.1%, with intermediate precision of 86.9-96.9% and variation coefficients of 3.4-5.7% and 5.9-7.1%, respectively. The results showed that among Fusarium toxins, generally DON was present in the highest concentration, followed by T-2 and finally ZEN in all tested swine feeds. Each of the mycotoxins was found above the limit of detection in all swine feedstuffs. Boars feed's DON (average ± standard deviation was 872 ± 139 µg kg -1 ) and ZEN (172 ± 18 µg kg -1 ) results of one of the manufacturers were above the guidance values. It indicates the necessity for efficient monitoring of DON, ZEN and T-2 mycotoxins in swine feeds.

  8. Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

    NASA Technical Reports Server (NTRS)

    Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David; Reid, Robert; Adams, Mike; Davis, Joe

    2008-01-01

    Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

  9. Customized broadband sloan-filters for the JST/T250 and JAST/T80 telescopes: summary of results

    NASA Astrophysics Data System (ADS)

    Brauneck, U.; Sprengard, R.; Bourquin, S.; Marín-Franch, A.

    2017-09-01

    The Centro de Estudios de Fisica del Cosmos de Aragon (CEFCA) will conduct a photometric sky survey with 2 new telescopes recently setup on the Javalambre mountain in Spain: the JST/T250 is a 2.55m telescope with a plate scale of 22.67"/mm and a 3° diameter field of view (FoV) and the auxiliary telescope JAST/T80 with a 82cm primary mirror and a FoV of 2 deg diameter. A multiple CCD (9k-by-9k array size, 10μm pixel size) mosaic camera is used in combination with filter trays or filter wheels, each containing a multitude of filters in dimensions of 101.7x96.5mm or 106.8x106.8mm. For this project, SCHOTT manufactured 56 specially designed narrow band steep edged bandpass interference filters and 5 broadband sloan-filters which were completed only recently. We report here on the results of the broadband sloanfilters with transmission bands of 324-400nm (sloan-u), 400-550nm (sloan-g), 550-700nm (sloan-r), 695-850nm (sloan-i) and 830-1200nm (sloan-z). The filters are composed of SCHOTT filterglasses and clearglass substrates coated with interference filters and represent an improvement of broadband sloan filters commonly used in astronomy. Inspite of the absorptive elements, the filters show maximum possible transmissions achieved by magnetron sputtered filter coatings. In addition the blocking of the filters is better than OD5 in the range 250-1050nm. A high image quality required a low transmitted wavefront error (<λ/8 locally, respectively <λ/2 globally) which was achieved by combining up to 2 substrates. We report on the spectral and interferometric results measured on the filters.

  10. Sodium reflux pool-boiler solar receiver on-sun test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andraka, C E; Moreno, J B; Diver, R B

    1992-06-01

    The efficient operation of a Stirling engine requires the application of a high heat flux to the relatively small area occupied by the heater head tubes. Previous attempts to couple solar energy to Stirling engines generally involved directly illuminating the heater head tubes with concentrated sunlight. In this study, operation of a 75-kW{sub t} sodium reflux pool-boiler solar receiver has been demonstrated and its performance characterized on Sandia's nominal 75-kW{sub t} parabolic-dish concentrator, using a cold-water gas-gap calorimeter to simulate Stirling engine operation. The pool boiler (and more generally liquid-metal reflux receivers) supplies heat to the engine in the formmore » of latent heat released from condensation of the metal vapor on the heater head tubes. The advantages of the pool boiler include uniform tube temperature, leading to longer life and higher temperature available to the engine, and decoupling of the design of the solar absorber from the engine heater head. The two-phase system allows high input thermal flux, reducing the receiver size and losses, therefore improving system efficiency. The receiver thermal efficiency was about 90% when operated at full power and 800{degree}C. Stable sodium boiling was promoted by the addition of 35 equally spaced artificial cavities in the wetted absorber surface. High incipient boiling superheats following cloud transients were suppressed passively by the addition of small amounts of xenon gas to the receiver volume. Stable boiling without excessive incipient boiling superheats was observed under all operating conditions. The receiver developed a leak during performance evaluation, terminating the testing after accumulating about 50 hours on sun. The receiver design is reported here along with test results including transient operations, steady-state performance evaluation, operation at various temperatures, infrared thermography, x-ray studies of the boiling behavior, and a postmortem analysis.« less

  11. MASH test 3-11 of the TxDOT T222 bridge rail.

    DOT National Transportation Integrated Search

    2016-07-01

    The objective of this research was to evaluate the impact performance of the TxDOT Type T222 : Bridge Rail according to the Manual for Assessing Safety Hardware (MASH) TL-3. The crash testing was : performed in accordance with the requirements of MAS...

  12. Cost consequences of point-of-care troponin T testing in a Swedish primary health care setting

    PubMed Central

    Andersson, Agneta; Janzon, Magnus; Karlsson, Jan-Erik; Levin, Lars-Åke

    2014-01-01

    Abstract Objective. To evaluate the safety and cost-effectiveness of point-of-care troponin T testing (POCT-TnT) for the management of patients with chest pain in primary care. Design. Prospective observational study with follow-up. Setting. Three primary health care (PHC) centres using POCT-TnT and four PHC centres not using POCT-TnT in south-east Sweden. Patients. All patients ≥ 35 years of age, contacting one of the PHC centres for chest pain, dyspnoea on exertion, unexplained weakness and/or fatigue, with no other probable cause than cardiac, were included. Symptoms must have commenced or worsened during the previous seven days. Main outcome measures. Emergency referral rates, diagnoses of acute myocardial infarction (AMI) or unstable angina (UA), and costs were collected for 30 days after the patient sought care at the PHC centre. Results. A total of 196 patients with chest pain were included: 128 in PHC centres with POCT-TnT and 68 in PHC centres without POCT-TnT. Fewer patients from the PHC centres with POCT-TnT (n = 32, 25%) were emergently referred to hospital than from centres without POCT-TnT (n = 29, 43%; p = 0.011). Eight patients (6.2%) from PHC centres with POCT-TnT were diagnosed with AMI or UA compared with six patients (8.8%) from centres without POCT-TnT (p = 0.565). Two patients with AMI or UA were classified as missed cases from PHC centres with POCT-TnT and there were no missed cases from PHC centres without POCT-TnT. SKr290 000 was saved per missed case of AMI or UA. Conclusion. The use of POCT-TnT in primary care may be cost saving but at the expense of missed cases. PMID:25434410

  13. Data analysis of P sub T/P sub S noseboom probe testing on F100 engine P680072 at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Foote, C. H.

    1980-01-01

    Results from the altitude testing of a P sub T/P sub S noseboom probe on the F100 engine are discused. The results are consistent with sea level test results. The F100 engine altitude test verified automatic downmatch with the engine pressure ratio control, and backup control inlet case static pressure demonstrated sufficient accuracy for backup control fuel flow scheduling. The production P6 probe measured Station 6 pressures accurately for both undistorted and distorted inlet airflows.

  14. Indiana allows testing of babies if mothers weren't tested.

    PubMed

    1998-05-01

    A new law in Indiana takes effect in July, allowing physicians to order HIV testing for newborns if their mothers were not tested during pregnancy. Senate Bill 261 capped months of legislative debate on how to reduce infections among newborns, and orders that the newborns be tested no later than 48 hours after birth. There are many requirements that the doctors must meet to avoid problems. Doctors must explain the purpose of the HIV-antibody test, the testing risks and benefits, and the routes of HIV transmission, including through breast feeding. Mothers must also be referred to other HIV prevention or care agencies. The physician must tell the infant's results to the mother, but the information is confidential. The State Department of Health expects the statute to have limited effect, as they estimate that only 10 babies a year will become infected at birth. However, studies have shown that about one-quarter of infants born to HIV-positive mothers become infected unless antiretroviral therapy is administered. A more effective strategy may be to test women during their pregnancy, rather than waiting to test the newborns.

  15. Factors associated with negative T-SPOT.TB results among smear-negative tuberculosis patients in China.

    PubMed

    Kang, Wanli; Wu, Meiying; Yang, Kunyun; Ertai, A; Wu, Shucai; Geng, Shujun; Li, Zhihui; Li, Mingwu; Pang, Yu; Tang, Shenjie

    2018-03-09

    We compared the positive rates of T-SPOT.TB and bacterial culture in the smear-negative PTB, and analyzed the factors affecting the results of negative T-SPOT.TB and bacterial culture. Retrospective evaluation of data from smear-negative PTB patients who underwent T-SPOT.TB and bacterial culture were done. The agreement and concordance were analyzed between T-SPOT.TB and bacterial culture. Multivariable logistic regression analysis was used to explore the factors associated with positive results of T-SPOT.TB and bacterial culture in smear-negative PTB. 858 eligible smear-negative PTB patients were included in the study. The agreement rate was 25.6% (22.7~28.5%) between T-SPOT.TB and bacterial culture in smear- negative PTB patients. The positive rate of T-SPOT.TB was higher than that of bacterial culture in smear-negative PTB patients (p < 0.001). There were nearly no concordance between T-SPOT.TB and bacterial culture (p > 0.05). Using multivariable logistic regression analysis we found that older age ≥ 60 years (OR = 0.469, 95% CI: 0.287-0.768) and decreased albumin (OR = 0.614, 95% CI: 0.380-0.992) were associated with negative diagnostic results of T-SPOT.TB in smear-negative PTB patients. Female (OR = 0.654, 95% CI: 0.431-0.992) were associated with negative diagnostic results of bacteria culture in smear-negative PTB patients. Our results indicated that the older age and decreased albumin were independently associated with negative T-SPOT.TB responses.

  16. Efficacy of Cyto-Chex blood preservative for delayed manual CD4 testing using Dynal T4 Quant CD4 test among HIV-infected persons in Zambia.

    PubMed

    Truett, April A; Letizia, Andrew; Malyangu, Evans; Sinyangwe, Frank; Morales, Brandi N; Crum, Nancy F; Crowe, Suzanne M

    2006-02-01

    Manual CD4 tests such as Dynal T4 Quant (Dynabeads, Dynal Biotech, Oslo, Norway) are less expensive alternatives to flow cytometry in resource-limited countries. Whereas blood preservatives have proven useful for stabilizing blood samples to allow delayed CD4 testing by flow cytometry, they have not been verified for manual tests. A method for preservation of blood prior to manual CD4 testing is needed for long-distance transport or sample batching. Blood from HIV-positive Zambian military beneficiaries was mixed (1:1) with Cyto-Chex (Streck Laboratories, La Vista, NE) blood preservative, and the blood was stored at refrigerated, ambient, and incubator (37 degrees C) temperatures prior to Dynabeads CD4 testing at 0, 3, 6, and 9 days after collection. Baseline flow cytometry and Dynabeads testing without preservative were performed for comparison. Twenty-seven patient samples were analyzed. Dynabeads vs. flow cytometry had a correlation coefficient (r) of 0.84. There was excellent correlation (r = 0.96) between baseline Dynabeads testing and Cyto-Chex-preserved samples. Refrigerated samples showed strong correlation with baseline Dynabeads (r = 0.93-0.95) on days 3, 6, and 9 without decline in CD4 count (P = 0.73). Samples stored at ambient temperature yielded inferior results (r = 0.76-0.81), with a significant decline in CD4 count by day 3 (P < 0.001). The incubator arm had especially poor correlation (r = 0.30-0.49). Addition of Cyto-Chex to peripheral blood (1:1) adequately preserves refrigerated blood samples for up to 9 days for subsequent testing with Dynabeads CD4 test. Cyto-Chex, however, cannot be recommended for delayed Dynabeads CD4 testing with storage at 37 degrees C or ambient temperatures in tropical areas similar to the site of this study.

  17. Structural specificity of Rn nuclease I as probed on yeast tRNA(Phe) and tRNA(Asp).

    PubMed Central

    Przykorska, A; el Adlouni, C; Keith, G; Szarkowski, J W; Dirheimer, G

    1992-01-01

    A single-strand-specific nuclease from rye germ (Rn nuclease I) was characterized as a tool for secondary and tertiary structure investigation of RNAs. To test the procedure, yeast tRNA(Phe) and tRNA(Asp) for which the tertiary structures are known, as well as the 3'-half of tRNA(Asp) were used as substrates. In tRNA(Phe) the nuclease introduced main primary cuts at positions U33 and A35 of the anticodon loop and G18 and G19 of the D loop. No primary cuts were observed within the double stranded stems. In tRNA(Asp) the main cuts occurred at positions U33, G34, U35, C36 of the anticodon loop and G18 and C20:1 positions in the D loop. No cuts were observed in the T loop in intact tRNA(Asp) but strong primary cleavages occurred at positions psi 55, C56, A57 within that loop in the absence of the tertiary interactions between T and D loops (use of 3'-half tRNA(Asp)). These results show that Rn nuclease I is specific for exposed single-stranded regions. Images PMID:1542562

  18. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  19. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  20. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Results of inspections and tests. 234.273 Section....273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with.../DOT inventory number, place and date, equipment tested, results of tests, repairs, replacements...

  1. A Comparison of the Results from General Tank Tests of 1/6- and 1/12-full-size Models of the British Singapore IIC Flying Boat

    NASA Technical Reports Server (NTRS)

    Truscott, Starr; Dawson, John R

    1942-01-01

    A 1/6-full-size model of the hull of the British Singapore IIC flying boat was tested in the NACA tank. The results are given in the form of charts and are compared with the results of previous tests made in the NACA tank of a 1/12-full-size model, published in NACA T.N. No. 580, and with the results of tests made in the British R.A.E. tank of another 1/6-full-size model of the same hull. When the data from the tests of the 1/6- and 1/12-full-size models were compared on the basis of Froude's law of comparison, differences were found. This fact supported the belief that the small scale of the model and the use of a model that was too small to suit the equipment of the NACA tank had caused the results of the tests of the 1/12-full-size model to be less reliable than the results of the tests of the 1/6-full-size model. The results of the tests of the two models agreed sufficiently well to show that test of a small model, if made meticulously and with suitable equipment, may give useable results, but that a larger model should be used whenever feasible. The results of the NACA tests of the 1/6-full-size model were found to be in good agreement with the R.A.E. tests of a model of the same size.

  2. Electrophysiological Analysis Shows Dizziness as the First Symptom in Human T Cell Lymphotropic Virus Type-Associated Myelopathy/Tropical Spastic Paraparesis

    PubMed Central

    Labanca, Ludimila; Starling, Ana Lúcia Borges; de Sousa-Pereira, Silvio Roberto; Romanelli, Luiz Cláudio Ferreira; Carneiro-Proietti, Anna Bárbara de Freitas; Carvalho, Lucas Novaes; Fernandes, Daniele Rosa

    2015-01-01

    Abstract Dizziness is a symptom in human T cell lymphotropic virus type-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and may occur due to vestibulospinal tract dysfunction. This tract can be assessed by an electrophysiological test called vestibular-evoked myogenic potential (VEMP). The aim was to correlate the result of VEMP generated by acoustic stimuli and dizziness in individuals with human T cell lymphotropic virus type 1 (HTLV-1)-asymptomatic infection and HAM/TSP. VEMP was recorded from the sternocleidomastoid muscle of 60 HTLV-1-negative adults (60±8 years) and 60 individuals infected with HTLV-1, 30 being asymptomatic (59±8 years) and 30 with HAM/TSP (59±8 years). In all groups, 90% of the participants were women. VEMP was generated by acoustic stimuli (short tone bursts), with an intensity of 118 dBHL and band-pass filter from 10 Hz to 1,500 Hz, and presented 200 stimuli at a frequency of 1,000 Hz with a record time of 60 ms. Of 60 HTLV-1-negative individuals, 14 (23%) reported dizziness; VEMP was normal in all. In the HTLV-1-asymptomatic group, 11(37%) complained of dizziness (p=0.31); VEMP was altered in four (40%) subjects with dizziness and in one (5%) without dizziness (p=0.00). In the group with HAM/TSP, dizziness was reported by 17 (57%) subjects (p=0.002); VEMP was altered in 11 (64%) with dizziness and in 5 (38%) without dizziness (p=0.15). Dizziness without an apparent etiology in HTLV-1-asymptomatic carriers deserves attention in terms of a possible subclinical spinal cord involvement that can be clarified through spinal electrophysiological tests. Damage of the vestibulospinal tract seems to occur in the early stages of HAM/TSP. PMID:25760424

  3. Electrophysiological analysis shows dizziness as the first symptom in human T cell lymphotropic virus type-associated myelopathy/tropical spastic paraparesis.

    PubMed

    Labanca, Ludimila; Starling, Ana Lúcia Borges; de Sousa-Pereira, Silvio Roberto; Romanelli, Luiz Cláudio Ferreira; de Freitas Carneiro-Proietti, Anna Bárbara; Carvalho, Lucas Novaes; Fernandes, Daniele Rosa; Utsch Gonçalves, Denise

    2015-06-01

    Dizziness is a symptom in human T cell lymphotropic virus type-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and may occur due to vestibulospinal tract dysfunction. This tract can be assessed by an electrophysiological test called vestibular-evoked myogenic potential (VEMP). The aim was to correlate the result of VEMP generated by acoustic stimuli and dizziness in individuals with human T cell lymphotropic virus type 1 (HTLV-1)-asymptomatic infection and HAM/TSP. VEMP was recorded from the sternocleidomastoid muscle of 60 HTLV-1-negative adults (60±8 years) and 60 individuals infected with HTLV-1, 30 being asymptomatic (59±8 years) and 30 with HAM/TSP (59±8 years). In all groups, 90% of the participants were women. VEMP was generated by acoustic stimuli (short tone bursts), with an intensity of 118 dBHL and band-pass filter from 10 Hz to 1,500 Hz, and presented 200 stimuli at a frequency of 1,000 Hz with a record time of 60 ms. Of 60 HTLV-1-negative individuals, 14 (23%) reported dizziness; VEMP was normal in all. In the HTLV-1-asymptomatic group, 11(37%) complained of dizziness (p=0.31); VEMP was altered in four (40%) subjects with dizziness and in one (5%) without dizziness (p=0.00). In the group with HAM/TSP, dizziness was reported by 17 (57%) subjects (p=0.002); VEMP was altered in 11 (64%) with dizziness and in 5 (38%) without dizziness (p=0.15). Dizziness without an apparent etiology in HTLV-1-asymptomatic carriers deserves attention in terms of a possible subclinical spinal cord involvement that can be clarified through spinal electrophysiological tests. Damage of the vestibulospinal tract seems to occur in the early stages of HAM/TSP.

  4. High signal intensity of intervertebral calcified disks on T1-weighted MR images resulting from fat content.

    PubMed

    Malghem, Jacques; Lecouvet, Frédéric E; François, Robert; Vande Berg, Bruno C; Duprez, Thierry; Cosnard, Guy; Maldague, Baudouin E

    2005-02-01

    To explain a cause of high signal intensity on T1-weighted MR images in calcified intervertebral disks associated with spinal fusion. Magnetic resonance and radiological examinations of 13 patients were reviewed, presenting one or several intervertebral disks showing a high signal intensity on T1-weighted MR images, associated both with the presence of calcifications in the disks and with peripheral fusion of the corresponding spinal segments. Fusion was due to ligament ossifications (n=8), ankylosing spondylitis (n=4), or posterior arthrodesis (n=1). Imaging files included X-rays and T1-weighted MR images in all cases, T2-weighted MR images in 12 cases, MR images with fat signal suppression in 7 cases, and a CT scan in 1 case. Histological study of a calcified disk from an anatomical specimen of an ankylosed lumbar spine resulting from ankylosing spondylitis was examined. The signal intensity of the disks was similar to that of the bone marrow or of perivertebral fat both on T1-weighted MR images and on all sequences, including those with fat signal suppression. In one of these disks, a strongly negative absorption coefficient was focally measured by CT scan, suggesting a fatty content. The histological examination of the ankylosed calcified disk revealed the presence of well-differentiated bone tissue and fatty marrow within the disk. The high signal intensity of some calcified intervertebral disks on T1-weighted MR images can result from the presence of fatty marrow, probably related to a disk ossification process in ankylosed spines.

  5. Non-Nuclear Validation Test Results of a Closed Brayton Cycle Test-Loop

    NASA Astrophysics Data System (ADS)

    Wright, Steven A.

    2007-01-01

    Both NASA and DOE have programs that are investigating advanced power conversion cycles for planetary surface power on the moon or Mars, or for next generation nuclear power plants on earth. Although open Brayton cycles are in use for many applications (combined cycle power plants, aircraft engines), only a few closed Brayton cycles have been tested. Experience with closed Brayton cycles coupled to nuclear reactors is even more limited and current projections of Brayton cycle performance are based on analytic models. This report describes and compares experimental results with model predictions from a series of non-nuclear tests using a small scale closed loop Brayton cycle available at Sandia National Laboratories. A substantial amount of testing has been performed, and the information is being used to help validate models. In this report we summarize the results from three kinds of tests. These tests include: 1) test results that are useful for validating the characteristic flow curves of the turbomachinery for various gases ranging from ideal gases (Ar or Ar/He) to non-ideal gases such as CO2, 2) test results that represent shut down transients and decay heat removal capability of Brayton loops after reactor shut down, and 3) tests that map a range of operating power versus shaft speed curve and turbine inlet temperature that are useful for predicting stable operating conditions during both normal and off-normal operating behavior. These tests reveal significant interactions between the reactor and balance of plant. Specifically these results predict limited speed up behavior of the turbomachinery caused by loss of load, the conditions for stable operation, and for direct cooled reactors, the tests reveal that the coast down behavior during loss of power events can extend for hours provided the ultimate heat sink remains available.

  6. Quench simulation results for a 12-T twin-aperture dipole magnet

    NASA Astrophysics Data System (ADS)

    Cheng, Da; Salmi, Tiina; Xu, Qingjin; Peng, Quanling; Wang, Chengtao; Wang, Yingzhe; Kong, Ershuai; Zhang, Kai

    2018-06-01

    A 12-T twin-aperture subscale dipole magnet is being developed for SPPC pre-study at the Institute of High Energy Physics (IHEP). The magnet is comprised of 6 double-pancake coils which include 2 Nb3Sn coils and 4 NbTi coils. As the stored energy of the magnet is 0.452 MJ and the operation margin is only about 20% at 4.2 K, a quick and effective quench protection system is necessary during the test of this high field magnet. For the design of the quench protection system, attention was not only paid to the hotspot temperature and terminal voltage, but also the temperature gradient during the quench process due to the poor mechanical characteristics of the Nb3Sn cables. With the adiabatic analysis, numerical simulation and the finite element simulation, an optimized protection method is adopted, which contains a dump resistor and quench heaters. In this paper, the results of adiabatic analysis and quench simulation, such as current decay, hot-spot temperature and terminal voltage are presented in details.

  7. Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

    NASA Technical Reports Server (NTRS)

    McIntire, Jeff; Moyer, David; McCarthy, James K.; DeLuccia, Frank; Xiong, Xiaoxiong; Butler, James J.; Guenther, Bruce

    2011-01-01

    Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

  8. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    ERIC Educational Resources Information Center

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  9. Surgical treatment of female stress urinary incontinence with a trans-obturator-tape (T.O.T.) Uratape: short term results of a prospective multicentric study.

    PubMed

    Costa, P; Grise, P; Droupy, S; Monneins, F; Assenmacher, C; Ballanger, P; Hermieu, J F; Delmas, V; Boccon-Gibod, L; Ortuno, C

    2004-07-01

    The aim of the study was to assess the efficacy and safety of a new minimally invasive surgical procedure using the Trans-Obturator-Tape Uratape to treat female stress urinary incontinence. 183 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (October 2001 to March 2003). 26 patients were previously operated for incontinence. 26 patients were operated at the same time for their genital prolapse. Mean age was 56 years (29-87). 50/183 patients were having mixed incontinence. A non-elastic, polypropylene tape (UraTape, Mentor-Porgès) with a silicon coated central part was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 7 months (1-21). At 1 year follow-up 80.5% of the patients were completely cured and 7.5% were improved. The overall peri-operative complication rate was 2.2% with no vascular, nerve or bowel injury. 6 patients (3.3%) had post-operative urinary retention. The present multicentric study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence, alone or in combination with prolapse repair. Copyright 2004 Elsevier B.V.

  10. Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aidala, C.A.; et al.

    The sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal ismore » $$2.8\\%\\oplus~15.5\\%/\\sqrt{E}$$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $$13.5\\%\\oplus 64.9\\%/\\sqrt{E}$$. These results demonstrate that the performance of the proposed calorimeter system is consistent with \\geant simulations and satisfies the sPHENIX specifications.« less

  11. The Edinburgh Social Cognition Test (ESCoT): Examining the effects of age on a new measure of theory of mind and social norm understanding

    PubMed Central

    Abrahams, Sharon; Auyeung, Bonnie; MacPherson, Sarah E.

    2018-01-01

    Current measures of social cognition have shown inconsistent findings regarding the effects of healthy aging. Moreover, no tests are currently available that allow clinicians and researchers to examine cognitive and affective theory of mind (ToM) and understanding of social norms within the same test. To address these limitations, we present the Edinburgh Social Cognition Test (ESCoT) which assesses cognitive and affective ToM and inter- and intrapersonal understanding of social norms. We examined the effects of age, measures of intelligence and the Broader Autism Phenotype (BAP) on the ESCoT and established tests of social cognition. Additionally, we investigated the convergent validity of the ESCoT based on traditional social cognition measures. The ESCoT was administered alongside Reading the Mind in Films (RMF), Reading the Mind in Eyes (RME), Judgement of Preference and Social Norm Questionnaire to 91 participants (30 aged 18–35 years, 30 aged 45–60 years and 31 aged 65–85 years). Poorer performance on the cognitive and affective ToM ESCoT subtests were predicted by increasing age. The affective ToM ESCoT subtest and RMF were predicted by gender, where being female predicted better performance. Unlike the ESCoT, better performance on the RMF was predicted by higher verbal comprehension and perceptual reasoning abilities, while better performance on the RME was predicted by higher verbal comprehension scores. Lower scores on inter-and intrapersonal understanding of social norms were both predicted by the presence of more autism-like traits while poorer interpersonal understanding of social norms performance was predicted by increasing age. These findings show that the ESCoT is a useful measure of social cognition and, unlike established tests of social cognition, performance is not predicted by measures of verbal comprehension and perceptual reasoning. This is particularly valuable to obtain an accurate assessment of the influence of age on our social

  12. The Edinburgh Social Cognition Test (ESCoT): Examining the effects of age on a new measure of theory of mind and social norm understanding.

    PubMed

    Baksh, R Asaad; Abrahams, Sharon; Auyeung, Bonnie; MacPherson, Sarah E

    2018-01-01

    Current measures of social cognition have shown inconsistent findings regarding the effects of healthy aging. Moreover, no tests are currently available that allow clinicians and researchers to examine cognitive and affective theory of mind (ToM) and understanding of social norms within the same test. To address these limitations, we present the Edinburgh Social Cognition Test (ESCoT) which assesses cognitive and affective ToM and inter- and intrapersonal understanding of social norms. We examined the effects of age, measures of intelligence and the Broader Autism Phenotype (BAP) on the ESCoT and established tests of social cognition. Additionally, we investigated the convergent validity of the ESCoT based on traditional social cognition measures. The ESCoT was administered alongside Reading the Mind in Films (RMF), Reading the Mind in Eyes (RME), Judgement of Preference and Social Norm Questionnaire to 91 participants (30 aged 18-35 years, 30 aged 45-60 years and 31 aged 65-85 years). Poorer performance on the cognitive and affective ToM ESCoT subtests were predicted by increasing age. The affective ToM ESCoT subtest and RMF were predicted by gender, where being female predicted better performance. Unlike the ESCoT, better performance on the RMF was predicted by higher verbal comprehension and perceptual reasoning abilities, while better performance on the RME was predicted by higher verbal comprehension scores. Lower scores on inter-and intrapersonal understanding of social norms were both predicted by the presence of more autism-like traits while poorer interpersonal understanding of social norms performance was predicted by increasing age. These findings show that the ESCoT is a useful measure of social cognition and, unlike established tests of social cognition, performance is not predicted by measures of verbal comprehension and perceptual reasoning. This is particularly valuable to obtain an accurate assessment of the influence of age on our social cognitive

  13. Results from 15years of quality surveillance for a National Indigenous Point-of-Care Testing Program for diabetes.

    PubMed

    Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina

    2017-12-01

    Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Advanced Stirling Convertor Dynamic Test Approach and Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Hill, Dennis; Ursic, Joseph J.

    2010-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Convertors (ASC) at NASA GRC undergo a vibration test sequence intended to simulate the vibration history that an ASC would experience when used in an ASRG for a space mission. This sequence includes testing at workmanship and flight acceptance levels interspersed with periods of extended operation to simulate prefueling and post fueling. The final step in the test sequence utilizes additional testing at flight acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit (ASRG EU) at LM. This paper outlines the overall test approach, summarizes the test results from the ASRG EU, describes the incorporation of those results into the test approach, and presents the results of applying the test approach to the ASC-1 #3 and #4 convertors. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.

  15. Evaluation of Series T22 Wet Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2017-01-01

    Several types of advanced wet tantalum capacitors, and series T22 in particular, are designed without internal Teflon sealing that is used for military grade, CLR style capacitors. This raises concerns regarding hermeticity of the single seal parts and their capability to withstand high internal gas pressures that might develop during operation in space. To address these issues, T22 series capacitors rated to 50 V and 125 V were subjected to highly accelerated life testing (HALT) at 125 C and rated voltage and step stress random vibration testing (RVT). To simulate conditions of storage or operation under increased internal gas pressure, the parts were stored at temperature of 150 C for 2500 hr (HTS150). Electrical characteristics of the parts were measured through the storage testing and the hermeticity leak rate was tested before and after HTS150. To assess thermo-mechanical robustness of the part, capacitors were manually soldered onto printed wired boards (PWB) and stressed by 1000 temperature cycles between -55 C and +125 C. The effect of temperature cycling was assessed by additional HALT at different temperatures. Results show that T22 series capacitors have robust design and can satisfy requirements for space applications.

  16. Tissue Non-specific Alkaline Phosphatase Expression is Needed for the Full Stimulation of T Cells and T Cell-Dependent Colitis.

    PubMed

    Hernández-Chirlaque, Cristina; Gámez-Belmonte, Reyes; Ocón, Borja; Martínez-Moya, Patricia; Wirtz, Stefan; Sánchez de Medina, Fermín; Martínez-Augustin, Olga

    2017-07-01

    Two alkaline phosphatase isoforms, intestinal [IAP] and tissue non-specific alkaline phosphatase [TNAP], are coexpressed in mouse colon, with the latter predominating in colitis. We aimed to examine the role of TNAP in T lymphocytes, using heterozygous TNAP+/- mice [as TNAP-/- mice are non-viable]. In vitro primary cultures and in vivo T cell models using TNAP+/- mice were used. Stimulated splenocytes [lipopolysaccharide and concanavalin A] and T lymphocytes [concanavalin A and a-CD3/a-CD28] showed a decreased cytokine production and expression when compared with wild-type [WT] cells. Decreased T cell activation was reproduced by the TNAP inhibitors levamisole, theophylline, and phenylalanine in WT cells. Intraperitoneal administration of anti-CD3 in vivo resulted in reduced plasma cytokine levels, and decreased activation of splenocytes and T cells ex vivo in TNAP+/- mice. We further tested the hypothesis that TNAP expressed in T lymphocytes is involved in T cell activation and inflammation, using the lymphocyte transfer model of colitis. Rag1-/- mice were transferred with T naïve cells [CD4+ CD62L+] from TNAP+/- or WT mice and developed colitis, which was attenuated in the group receiving TNAP+/- cells. Compared with WT, T cells from TNAP+/- mice showed a decreased capacity for proliferation, with no change in differentiation. Our results offer clear evidence that TNAP modulates T lymphocyte function and specifically T cell-dependent colitis. This was associated with distinct changes in the type of TNAP expressed, probably because of changes in glycosylation. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com

  17. Training Materials and Data Requirements for Turret Organizational Maintenance Trainer (TOM-T) Training Test Support Plan

    DTIC Science & Technology

    1980-05-01

    performed on the TOM-T Turret Mock- Up . Those marked with a number symbol (#) can be done on the TOM-T Programmable Maintenance Trainer. Tasks with both...an asterisk and a number symbol (*/#) are those which can be performed partially on the turret mock- up and partially on the programmable trainer...time, the tasks serve as prerequisites to troubleshooting. With the exception of setting- up , testing, and shutting-down the STE/XMI test set, and

  18. Influence of Blood Lipids on Global Coagulation Test Results

    PubMed Central

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon

    2015-01-01

    Background High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). Methods PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). Results The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. Conclusion High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels. PMID:25553275

  19. Clinical implications of proliferation activity in T1 or T2 male gastric cancer patients.

    PubMed

    Kim, Young-Woo; Eom, Bang Wool; Kook, Myeong-Cherl; Kim, Han-Seong; Kim, Mi-Kyung; Hwang, Hai-Li; Chandra, Vishal; Poojan, Shiv; Song, Yura; Koh, Jae-Soo; Bae, Chang-Dae; Ro, Jungsil; Hong, Kyeong-Man

    2015-11-06

    Proliferation activity has already been established as a prognostic marker or as a marker for anticancer drug sensitivity. In gastric cancer, however, the prognostic significance of proliferation activity is still being debated. Several studies evaluating proliferation activity using Ki-67 have shown controversial results in terms of the relationship between proliferation activity and overall survival (OS) or drug sensitivity in gastric cancer patients. Because cytoskeleton-associated protein 2 (CKAP2) staining has recently been introduced as a marker of proliferation activity, we analyzed 437 gastric cancer tissues through CKAP2 immunohistochemistry, and we evaluated the chromatin CKAP2-positive cell count (CPCC) for proliferation activity. Although the CPCC did not show any significant correlation with OS in the male, female or total number of cases, it did show a significant correlation in the T1 or T2 male patient subgroup, according to log-rank tests (P=0.001) and univariate analysis (P=0.045). Additionally, multivariate analysis with the Cox proportional hazard regression model showed a significant correlation between the CPCC and OS (P=0.039) for the co-variables of age, gender, T stage, N stage, histology, tumor location, tumor size and adjuvant chemotherapy. In male gastric cancer cell lines, faster-growing cancer cells showed higher sensitivity to cisplatin than slow-growing cells. Thus our study indicates that CPCC-measured proliferation activity demonstrates a significantly worse prognosis in T1 or T2 male gastric cancer patients. The CPCC will help to more precisely classify gastric cancer patients and to select excellent candidates for adjuvant chemotherapy, which in turn will facilitate further clinical chemotherapeutic trials.

  20. (Updated) Targeted T-Cell Therapy Shows Promise Against Triple-Negative Breast Cancer | Poster

    Cancer.gov

    (Updated May 8) A study led by the Baylor College of Medicine and supported by NCI’s Center for Cancer Research (CCR) has demonstrated that chimeric antigen receptor (CAR) T-cell therapy can be used to treat solid triple-negative breast cancer (TNBC) tumors. The investigation is the first work using CAR T-cell therapy against TEM8, a cell surface protein that is frequently overexpressed both in TNBC cells and cells lining the blood vessels that sustain TNBC tumors.

  1. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  2. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  3. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  4. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  5. 40 CFR 204.57-5 - Reporting of test results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Reporting of test results. 204.57-5... of test results. (a)(1) The manufacturer shall submit a copy of the test report for all testing... compressor. (iii) Compressor serial number. (iv) Test results by serial numbers (3) The first test report for...

  6. Drug and alcohol testing results : 1997 annual report

    DOT National Transportation Integrated Search

    1998-12-01

    The Drug and Alcohol Testing Results 1997 Annual Report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1997. The report covers testing results for the following drug type...

  7. Fracture mechanics data for 2024-T861 and 2124-T851 aluminum

    NASA Technical Reports Server (NTRS)

    Pionke, L. J.; Linback, R. K.

    1974-01-01

    The fracture toughness and fatigue flaw growth characteristics of 2024-T861 and 2124-T851 aluminum were evaluated under plane stress conditions. Center cracked tension specimens were employed to evaluate these properties under a number of different test conditions which included variations in specimen thickness, specimen orientation, test environment, and initial flaw size. The effect of buckling was also investigated for all tests of thin gage specimens, and the effect of frequency and stress ratio was evaluated for the cyclic tests. Fracture toughness test results were analyzed and presented in terms of fracture resistance curves; fatigue flaw growth data was analyzed using empirical rate models. The results of the study indicate that both fracture toughness and resistance to fatigue crack growth improve with increasing temperature and decreasing thickness. The presence of buckling during testing of thin gage panels was found to degrade the resistance to fatigue flaw growth only at elevated temperatures.

  8. Transcranial direct current stimulation (tDCS) of frontal cortex decreases performance on the WAIS-IV intelligence test.

    PubMed

    Sellers, Kristin K; Mellin, Juliann M; Lustenberger, Caroline M; Boyle, Michael R; Lee, Won Hee; Peterchev, Angel V; Fröhlich, Flavio

    2015-09-01

    Transcranial direct current stimulation (tDCS) modulates excitability of motor cortex. However, there is conflicting evidence about the efficacy of this non-invasive brain stimulation modality to modulate performance on cognitive tasks. Previous work has tested the effect of tDCS on specific facets of cognition and executive processing. However, no randomized, double-blind, sham-controlled study has looked at the effects of tDCS on a comprehensive battery of cognitive processes. The objective of this study was to test if tDCS had an effect on performance on a comprehensive assay of cognitive processes, a standardized intelligence quotient (IQ) test. The study consisted of two substudies and followed a double-blind, between-subjects, sham-controlled design. In total, 41 healthy adult participants were included in the final analysis. These participants completed the Wechsler Adult Intelligence Scale, Fourth Edition (WAIS-IV) as a baseline measure. At least one week later, participants in substudy 1 received either bilateral tDCS (anodes over both F4 and F3, cathode over Cz, 2 mA at each anode for 20 min) or active sham tDCS (2 mA for 40 s), and participants in substudy 2 received either right or left tDCS (anode over either F4 or F3, cathode over Cz, 2 mA for 20 min). In both studies, the WAIS-IV was immediately administered following stimulation to assess for performance differences induced by bilateral and unilateral tDCS. Compared to sham stimulation, right, left, and bilateral tDCS reduced improvement between sessions on Full Scale IQ and the Perceptual Reasoning Index. This demonstration that frontal tDCS selectively degraded improvement on specific metrics of the WAIS-IV raises important questions about the often proposed role of tDCS in cognitive enhancement. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Influence of the creep ageing process on the fatigue properties of components from V95pchT2 (analog 7175T76) and V95ochT2 (analog 7475) aluminium alloys

    NASA Astrophysics Data System (ADS)

    Larichkin, A.; Zakharchenko, K.; Gorev, B.; Kapustin, V.; Maksimovskiy, E.

    2017-10-01

    Influence of conditions of technological process of forming thick panels of a given geometry on fatigue limit of flat specimens from the V95ochT2 and V95pchT2 (analogues 7475 and 7175T76) alloys (Al-Mg-Cu-Zn) has been analysed. The process has been simulated experimentally on flat samples for temperatures 20, 165 and 420°C. The process includes: non-elastic strain in the range 10-5 - 10-2 s-1 up to 2% of total strain, followed by heat treatment according to T2 mode (quenching and aging). Fatigue life tests were carried out both on solid samples and on samples with a hole. It has been shown that resistance to fatigue of the observed alloys after forming at the annealing temperature (420°C) is comparable to the basic material resistance to fatigue. Meso-structure analysis showed absence of stress in grains. It is established that, on average, the shape of the grains is the same for a series of samples for different temperatures and loading rates. The results of testing samples with a hole showed that fatigue limit slightly decreases in samples which were previously deformed at (420°C), with respect to the durability of samples from the material in basic state. With an increase in rate of pre-strain, the relative number of cycles before destruction occurs increased.

  10. Particulate Titanium Matrix Composites Tested--Show Promise for Space Propulsion Applications

    NASA Technical Reports Server (NTRS)

    Lerch, Bradley A.; Ellis, J. Rodney; Arnold. Steven M.

    2004-01-01

    Uniformly distributed particle-strengthened titanium matrix composites (TMCs) can be manufactured at lower cost than many types of continuous-fiber composites. The innovative manufacturing technology combines cold and hot isostatic pressing procedures to produce near-final-shape components. Material stiffness is increased up to 26-percent greater than that of components made with conventional titanium materials at no significant increase in the weight. The improved mechanical performance and low-cost manufacturing capability motivated an independent review to assess the improved properties of ceramic titanium carbide (TiC) particulate-reinforced titanium at elevated temperature. Researchers at the NASA Glenn Research Center creatively designed and executed deformation and durability tests to reveal operating regimes where these materials could lower the cost and weight of space propulsion systems. The program compares the elevated-temperature performance of titanium alloy Ti-6Al-4V matrix material to an alloy containing 10 wt% of TiC particles. Initial experiments showed that at these relatively low particle concentrations the material stiffness of the TMC was improved 20 percent over that of the plain Ti-6Al-4V alloy when tested at 427 C. The proportional limit and ultimate strength of the composite in tension are 21- and 14-percent greater than those of the plain alloy. Compression tests showed that the proportional limit is about 30 percent greater for TMC than for the plain alloy. The enhanced deformation resistance of the TMC was also evident in a series of tensile and compressive stress relaxation tests that were made. Specimens were subjected to tensile or compressive strain amplitudes of 0.75 percent for 24 hr followed by a return to zero strain imposed for 24 hr. The stress relaxation data were normalized with respect to the maximum stress for each case and plotted as a function of time in the following graph. Tensile stresses relaxed 19 percent for the

  11. NEXT Single String Integration Test Results

    NASA Technical Reports Server (NTRS)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  12. Detection of epidermal growth factor receptor gene T790M mutation in cytology samples using the cobas® EGFR mutation test.

    PubMed

    Satouchi, Miyako; Tanaka, Hiroshi; Yoshioka, Hiroshige; Shimokawaji, Tadasuke; Mizuno, Keiko; Takeda, Koji; Yoshino, Ichiro; Seto, Takashi; Kurata, Takayasu; Tashiro, Naoki; Hagiwara, Koichi

    2017-09-01

    Detection of epidermal growth factor receptor (EGFR) gene mutations is essential in deciding therapeutic strategy in non-small cell lung cancer (NSCLC) patients at initial diagnosis. Moreover, in EGFR mutation-positive (EGFRm) NSCLC patients, re-biopsy at disease progression to clarify resistance mechanisms is also important. However, collecting histology samples is often difficult because of inaccessibility and invasiveness. In some cases, only cytology samples can be collected, and studies have reported that cytology samples are appropriate for EGFR gene mutation testing. The cobas ® EGFR Mutation Test (Roche Molecular Systems Inc., Branchburg, New Jersey, USA) is approved as a companion diagnostic for osimertinib, a third-generation EGFR-tyrosine kinase inhibitor approved in Japan. However, it is not clear whether the EGFR T790M mutation can be detected in cytology samples using this test. The primary objective of this study was to assess concordance of EGFR T790M gene mutation detection between histology and matched cytology samples using the cobas ® EGFR Mutation Test. We conducted a multicenter, observational study in Japan. Overall, 41 EGFRm NSCLC patients who had both histology and cytology samples collected at the same time at re-biopsy and with the results of EGFR mutation test using histology samples were enrolled. The EGFR mutation status of both sample types was tested using the cobas ® EGFR Mutation Test and the concordance rates were calculated. The EGFR T790M mutation detection rate in histology and cytology samples was 42.5% and 37.5%, respectively. The overall percent agreement between the histology and cytology samples was 91.7%. These data demonstrate that the cobas ® EGFR Mutation Test can detect the EGFR T790M mutation in both cytology and histology samples. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  14. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  15. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  16. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  17. 42 CFR 493.1281 - Standard: Comparison of test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Comparison of test results. 493.1281... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the... between test results using the different methodologies, instruments, or testing sites. (b) The laboratory...

  18. Measurement and interpretation of skin prick test results.

    PubMed

    van der Valk, J P M; Gerth van Wijk, R; Hoorn, E; Groenendijk, L; Groenendijk, I M; de Jong, N W

    2015-01-01

    There are several methods to read skin prick test results in type-I allergy testing. A commonly used method is to characterize the wheal size by its 'average diameter'. A more accurate method is to scan the area of the wheal to calculate the actual size. In both methods, skin prick test (SPT) results can be corrected for histamine-sensitivity of the skin by dividing the results of the allergic reaction by the histamine control. The objectives of this study are to compare different techniques of quantifying SPT results, to determine a cut-off value for a positive SPT for histamine equivalent prick -index (HEP) area, and to study the accuracy of predicting cashew nut reactions in double-blind placebo-controlled food challenge (DBPCFC) tests with the different SPT methods. Data of 172 children with cashew nut sensitisation were used for the analysis. All patients underwent a DBPCFC with cashew nut. Per patient, the average diameter and scanned area of the wheal size were recorded. In addition, the same data for the histamine-induced wheal were collected for each patient. The accuracy in predicting the outcome of the DBPCFC using four different SPT readings (i.e. average diameter, area, HEP-index diameter, HEP-index area) were compared in a Receiver-Operating Characteristic (ROC) plot. Characterizing the wheal size by the average diameter method is inaccurate compared to scanning method. A wheal average diameter of 3 mm is generally considered as a positive SPT cut-off value and an equivalent HEP-index area cut-off value of 0.4 was calculated. The four SPT methods yielded a comparable area under the curve (AUC) of 0.84, 0.85, 0.83 and 0.83, respectively. The four methods showed comparable accuracy in predicting cashew nut reactions in a DBPCFC. The 'scanned area method' is theoretically more accurate in determining the wheal area than the 'average diameter method' and is recommended in academic research. A HEP-index area of 0.4 is determined as cut-off value for a

  19. Medical University admission test: a confirmatory factor analysis of the results.

    PubMed

    Luschin-Ebengreuth, Marion; Dimai, Hans P; Ithaler, Daniel; Neges, Heide M; Reibnegger, Gilbert

    2016-05-01

    The Graz Admission Test has been applied since the academic year 2006/2007. The validity of the Test was demonstrated by a significant improvement of study success and a significant reduction of dropout rate. The purpose of this study was a detailed analysis of the internal correlation structure of the various components of the Graz Admission Test. In particular, the question investigated was whether or not the various test parts constitute a suitable construct which might be designated as "Basic Knowledge in Natural Science." This study is an observational investigation, analyzing the results of the Graz Admission Test for the study of human medicine and dentistry. A total of 4741 applicants were included in the analysis. Principal component factor analysis (PCFA) as well as techniques from structural equation modeling, specifically confirmatory factor analysis (CFA), were employed to detect potential underlying latent variables governing the behavior of the measured variables. PCFA showed good clustering of the science test parts, including also text comprehension. A putative latent variable "Basic Knowledge in Natural Science," investigated by CFA, was indeed shown to govern the response behavior of the applicants in biology, chemistry, physics, and mathematics as well as text comprehension. The analysis of the correlation structure of the various test parts confirmed that the science test parts together with text comprehension constitute a satisfactory instrument for measuring a latent construct variable "Basic Knowledge in Natural Science." The present results suggest the fundamental importance of basic science knowledge for results obtained in the framework of the admission process for medical universities.

  20. Test results for rotordynamic coefficients of anti-swirl self-injection seals

    NASA Technical Reports Server (NTRS)

    Kim, C. H.; Lee, Y. B.

    1994-01-01

    Test results are presented for rotordynamic coefficients and leakage for three annular seals which use anti-swirl self-injection concept to yield significant improvement in whirl frequency ratios as compared to smooth and damper seals. A new anti-swirl self-inection mechanism is achieved by deliberately machining self-injection holes inside the seal stator mechanism which is used to achieve effective reduction of the tangential flow which is considered as a prime cause of rotor instability in high performance turbomachinery. Test results show that the self-injection mechanism significantly improves whirl frequency ratios; however, the leakage performance degrades due to the introduction of the self-injection mechanism. Through a series of the test program, an optimum anti-swirl self-injection seal which uses a labyrinth stator surface with anti-axial flow injections is selected to obtain a significant improvement in the whirl frequency ratio as compared to a damper seal, while showing moderate leakage performance. Best whirl frequency ratio is achieved by an anti-swirl self-injection seal of 12 holes anti-swirl and 6 degree anti-leakage injection with a labyrinth surface configuration. When compared to a damper seal, the optimum configuration outperforms the whirl frequency ratio by a factor of 2.

  1. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  2. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  3. 49 CFR 229.313 - Product testing results and records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Product testing results and records. 229.313....313 Product testing results and records. (a) Results of product testing conducted by a railroad as... by this subpart. Results of product testing conducted by a vendor or private equipment owner in...

  4. MUC-4 Test Results and Analysis

    DTIC Science & Technology

    1992-01-01

    PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 MUC3 MUC4 STEMS 15,285 INFLECTED FORMS 14,56 1 TOTALS est at 10,000...34 . As an indication of system development during MUC4 , we can compare our TST3 results with our results on th e MUC-4 interim test (TST2) . The relevant... MUC4 Interim Test) Summary Scores SLOT POS ACT COR PAR INC ICR IPA SPU MIS NON REC PRE OVG inc-total 529 1189 160 63 24 0 23 942 282 718 36 16 79 perp

  5. 26 CFR 1.883-4T - Qualified shareholder stock ownership test (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Qualified shareholder stock ownership test... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Foreign Corporations § 1.883-4T Qualified shareholder stock...)(E) through (e)(1). (2) With respect to all qualified shareholders relied upon to satisfy the 50...

  6. Pressurized fluidized-bed component test program shows good promise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-04-01

    The test program described has involved extensive theoretical and laboratory work since 1976, which culminated in a series of PFBC rig tests at the Coal Utilization Research Laboratories (CURL) in Leatherhead, England, and eventually in the design and construction of a component test facility (CTF) at the Oresund Power Station of Sydkraft in Malmo, Sweden. The rig tests are listed. Those preceding the 1000-hr test in 1979 were carried out with and without cooling tubes in the bed, and with different bed characteristics; the main emphasis was on gas clean-up, combustion efficiency, and emission of sulfur and nitrogen oxides. Inmore » these tests, the exhaust gases from the PFBC were passed through a cyclone train containing two cyclones to remove particulate matter, and then through a static cascade that contained parts of turbine blades from an ASEA STAL GT-120 machine. Good performance data, for the most part, are reported. 4 references, 3 figures.« less

  7. Electrogeochemical sampling with NEOCHIM - results of tests over buried gold deposits

    USGS Publications Warehouse

    Leinz, R.W.; Hoover, D.B.; Fey, D.L.; Smith, D.B.; Patterson, T.

    1998-01-01

    Electrogeochemical extraction methods are based on the migration of ions in an electric field. Ions present in soil moisture are transported by an applied current into fluids contained in special electrodes placed on the soil. The fluids are then collected and analyzed. Extractions are governed by Faraday's and Ohm's laws and are modeled by the operation of a simple Hittord transference apparatus. Calculations show that the volume of soil sampled in an ideal electrogeochemical extraction can be orders of magnitude greater than the volumes used in more popular geochemical extraction methods, although this has not been verified experimentally. CHIM is a method of in-situ electrogeochemical extraction that was developed in the former Soviet Union and has been tested and applied internationally to exploration for buried mineral deposits. Tests carried out at the US Geological Survey (USGS) indicated that there were problems inherent in the use of CHIM technology. The cause of the problems was determined to be the diffusion of acid from the conventional electrode into the soil. The NEOCHIM electrode incorporates two compartments and a salt bridge in a design that inhibits diffusion of acid and enables the collection of anions or cations. Tests over a gold-enriched vein in Colorado and over buried, Carlin-type, disseminated gold deposits in northern Nevada show that there are similarities and differences between NEOCHIM results and those by partial extractions of soils which include simple extractions with water, dilute acids and solutions of salts used as collector fluids in the electrodes. Results of both differ from the results obtained by total chemical digestion. The results indicate that NEOCHIM responds to mineralized faults associated with disseminated gold deposits whereas partial and total chemical extraction methods do not. This suggests that faults are favored channels for the upward migration of metals and that NEOCHIM may be more effective in exploration

  8. Intention to communicate BRCA1/BRCA2 genetic test results to the family.

    PubMed

    Barsevick, Andrea M; Montgomery, Susan V; Ruth, Karen; Ross, Eric A; Egleston, Brian L; Bingler, Ruth; Malick, John; Miller, Suzanne M; Cescon, Terrence P; Daly, Mary B

    2008-04-01

    Guided by the theory of planned behavior, this analysis explores the communication skills of women who had genetic testing for BRCA1 and BRCA2. The key outcome was intention to tell test results to adult first-degree relatives. The theory predicts that global and specific attitudes, global and specific perceived social norms, and perceived control will influence the communication of genetic test results. A logistic regression model revealed that global attitude (p < .05), specific social influence (p < .01), and perceived control (p < .05) were significant predictors of intention to tell. When gender and generation of relatives were added to the regression, participants were more likely to convey genetic test results to female than to male relatives (p < .05) and were also more likely to communicate test results to children (p < .01) or siblings (p < .05) than to parents. However, this association depended on knowing the relative's opinion of genetic testing. Intention to tell was lowest among participants who did not know their relative's opinion. These results extend the theory of planned behavior by showing that gender and generation influence intention when the relative's opinion is unknown. (c) 2008 APA, all rights reserved.

  9. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Results of inspections and tests. 234.273 Section... Maintenance, Inspection, and Testing Inspections and Tests § 234.273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with this part shall be recorded on forms provided by...

  10. 49 CFR 234.273 - Results of inspections and tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Results of inspections and tests. 234.273 Section... Maintenance, Inspection, and Testing Inspections and Tests § 234.273 Results of inspections and tests. (a) Results of inspections and tests made in compliance with this part shall be recorded on forms provided by...

  11. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    NASA Technical Reports Server (NTRS)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  12. On the convexity of ROC curves estimated from radiological test results

    PubMed Central

    Pesce, Lorenzo L.; Metz, Charles E.; Berbaum, Kevin S.

    2010-01-01

    Rationale and Objectives Although an ideal observer’s receiver operating characteristic (ROC) curve must be convex — i.e., its slope must decrease monotonically — published fits to empirical data often display “hooks.” Such fits sometimes are accepted on the basis of an argument that experiments are done with real, rather than ideal, observers. However, the fact that ideal observers must produce convex curves does not imply that convex curves describe only ideal observers. This paper aims to identify the practical implications of non-convex ROC curves and the conditions that can lead to empirical and/or fitted ROC curves that are not convex. Materials and Methods This paper views non-convex ROC curves from historical, theoretical and statistical perspectives, which we describe briefly. We then consider population ROC curves with various shapes and analyze the types of medical decisions that they imply. Finally, we describe how sampling variability and curve-fitting algorithms can produce ROC curve estimates that include hooks. Results We show that hooks in population ROC curves imply the use of an irrational decision strategy, even when the curve doesn’t cross the chance line, and therefore usually are untenable in medical settings. Moreover, we sketch a simple approach to improve any non-convex ROC curve by adding statistical variation to the decision process. Finally, we sketch how to test whether hooks present in ROC data are likely to have been caused by chance alone and how some hooked ROCs found in the literature can be easily explained as fitting artifacts or modeling issues. Conclusion In general, ROC curve fits that show hooks should be looked upon with suspicion unless other arguments justify their presence. PMID:20599155

  13. Tanzania Health Information Technology (T-HIT) System: Pilot Test of a Tablet-Based System to Improve Prevention of Mother-to-Child Transmission of HIV

    PubMed Central

    Bull, Sheana; Nyanza, Elias C; Ngallaba, Sospatro E

    2018-01-01

    Background The prevention of mother-to-child transmission (PMTCT) of HIV requires innovative solutions. Although routine monitoring is effective in some areas, standardized and easy-to-scale solutions to identify and monitor pregnant women, test them for HIV, and treat them and their children is still lacking. Mobile health (mHealth) offers opportunities for surveillance and reporting in rural areas of low- and middle-income countries. Objective The aim of this study was to document the preliminary impacts of the Tanzania Health Information Technology (T-HIT) system mHealth intervention aimed at health workers for PMTCT care delivery and capacity building in a rural area of Tanzania. Methods We developed T-HIT as a tablet-based system for an electronic data collection system designed to capture and report PMTCT data during antenatal, delivery, and postnatal visits in Misungwi, Tanzania. T-HIT was tested by health workers in a pilot randomized trial comparing seven sites using T-HIT assigned at random to seven control sites; all sites maintained standard paper record-keeping during the pilot intervention period. We compared numbers of antenatal visits, number of HIV tests administered, and women testing positive across all sites. Results Health workers recorded data from antenatal visits for 1530 women; of these, 695 (45.42%) were tested for HIV and 3.59% (55/1530) tested positive. Health workers were unable to conduct an HIV test for 103 women (6.73%, 103/1530) because of lack of reagent, which is not captured on paper logs. There was no difference in the activity level for testing when comparing sites T-HIT to non-T-HIT sites. We observed a significant postintervention increase in the numbers of women testing positive for HIV compared with the preintervention period (P=.04), but this was likely not attributable to the T-HIT system. Conclusions T-HIT had a high degree of acceptability and feasibility and is perceived as useful by health workers, who documented more

  14. Low-dose controlled release of mTOR inhibitors maintains T cell plasticity and promotes central memory T cells.

    PubMed

    Gammon, Joshua M; Gosselin, Emily A; Tostanoski, Lisa H; Chiu, Yu-Chieh; Zeng, Xiangbin; Zeng, Qin; Jewell, Christopher M

    2017-10-10

    An important goal for improving vaccine and immunotherapy technologies is the ability to provide further control over the specific phenotypes of T cells arising from these agents. Along these lines, frequent administration of rapamycin (Rapa), a small molecule inhibitor of the mammalian target of rapamycin (mTOR), exhibits a striking ability to polarize T cells toward central memory phenotypes (T CM ), or to suppress immune function, depending on the concentrations and other signals present during administration. T CM exhibit greater plasticity and proliferative capacity than effector memory T cells (T EFF ) and, therefore, polarizing vaccine-induced T cells toward T CM is an intriguing strategy to enhance T cell expansion and function against pathogens or tumors. Here we combined biodegradable microparticles encapsulating Rapa (Rapa MPs) with vaccines composed of soluble peptide antigens and molecular adjuvants to test if this approach allows polarization of differentiating T cells toward T CM . We show Rapa MPs modulate DC function, enhancing secretion of inflammatory cytokines at very low doses, and suppressing function at high doses. While Rapa MP treatment reduced - but did not stop - T cell proliferation in both CD4 + and CD8 + transgenic T cell co-cultures, the expanding CD8 + T cells differentiated to higher frequencies of T CM at low doses of MP Rapa MPs. Lastly, we show in mice that local delivery of Rapa MPs to lymph nodes during vaccination either suppresses or enhances T cell function in response to melanoma antigens, depending on the dose of drug in the depots. In particular, at low Rapa MP doses, vaccines increased antigen-specific T CM , resulting in enhanced T cell expansion measured during subsequent booster injections over at least 100days. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Fatigue Strength and Related Characteristics of Aircraft Joints I : Comparison of Spot-Weld and Rivet Patterns in 24s-t Alclad and 75s-t Alclad

    NASA Technical Reports Server (NTRS)

    Russell, H W; Jackson, L R; Grover, H J; Beaver, W W

    1944-01-01

    Report contains detailed results of a number of fatigue tests on spot-welded joints in aluminum alloys. The tests described include: (1) fatigue tests on spot-welded lap joints in sheets of unequal thickness of alclad 24s-t. These tests indicate that the fatigue strength of a spot-welded joint in sheets of two different gages is slightly higher than that of a similar joint in two sheets of the thinner gage but definitely lower than that of a similar joint in two sheets of the thicker gage. (2) Fatigue tests on spot-welded alclad 75s-t spot-welded lap-joint specimens of alclad 75s-t were not any stronger in fatigue than similar specimens of alclad 24s-t. (3) Fatigue tests on lap-joint specimens spot -welded after various surface preparations--these included ac welding wire-brushed surfaces, dc welding wire-brushed surfaces, and dc welding chemically cleaned surfaces. While the ac welds were strongest statically, the dc welds on wire-brushed surfaces were strongest in fatigue. Specimens prepared in this way were very nearly as strong as the best riveted specimens tested for comparison. (4) Fatigue tests on specimens spot-welded with varying voltage so as to include a wide range of static spot-weld strengths. The fatigue strengths were in the same order as the static strengths but showed less range. (author)

  16. Interactive binocular treatment (I-BiT) for amblyopia: results of a pilot study of 3D shutter glasses system.

    PubMed

    Herbison, N; Cobb, S; Gregson, R; Ash, I; Eastgate, R; Purdy, J; Hepburn, T; MacKeith, D; Foss, A

    2013-09-01

    A computer-based interactive binocular treatment system (I-BiT) for amblyopia has been developed, which utilises commercially available 3D 'shutter glasses'. The purpose of this pilot study was to report the effect of treatment on visual acuity (VA) in children with amblyopia. Thirty minutes of I-BiT treatment was given once weekly for 6 weeks. Treatment sessions consisted of playing a computer game and watching a DVD through the I-BiT system. VA was assessed at baseline, mid-treatment, at the end of treatment, and at 4 weeks post treatment. Standard summary statistics and an exploratory one-way analysis of variance (ANOVA) were performed. Ten patients were enrolled with strabismic, anisometropic, or mixed amblyopia. The mean age was 5.4 years. Nine patients (90%) completed the full course of I-BiT treatment with a mean improvement of 0.18 (SD=0.143). Six out of nine patients (67%) who completed the treatment showed a clinically significant improvement of 0.125 LogMAR units or more at follow-up. The exploratory one-way ANOVA showed an overall effect over time (F=7.95, P=0.01). No adverse effects were reported. This small, uncontrolled study has shown VA gains with 3 hours of I-BiT treatment. Although it is recognised that this pilot study had significant limitations-it was unblinded, uncontrolled, and too small to permit formal statistical analysis-these results suggest that further investigation of I-BiT treatment is worthwhile.

  17. Environmental testing and laser transmission results for ruggedized high power IR fiber cables

    NASA Astrophysics Data System (ADS)

    Busse, Lynda; Kung, Frederic; Florea, Catalin; Shaw, Brandon; Aggarwal, Ishwar; Sanghera, Jas

    2013-03-01

    We present successful results of high mid-IR laser power transmission as well as MIL-SPEC environmental testing (thermal cycling and vibration testing) of ruggedized, IR-transmitting chalcogenide glass fiber cables. The cables tested included chalcogenide fiber cables with endfaces imprinted with anti-reflective "moth eye" surfaces, whereby the reflection loss is reduced from about 17% per end to less than 3%. The cables with these moth eye surfaces also show excellent laser damage resistance.

  18. Multispecific T cell response and negative HCV RNA tests during acute HCV infection are early prognostic factors of spontaneous clearance

    PubMed Central

    Spada, E; Mele, A; Berton, A; Ruggeri, L; Ferrigno, L; Garbuglia, A R; Perrone, M P; Girelli, G; Del Porto, P; Piccolella, E; Mondelli, M U; Amoroso, P; Cortese, R; Nicosia, A; Vitelli, A; Folgori, A

    2004-01-01

    Background/Aims: Hepatitis C virus (HCV) infection results in a high frequency of chronic disease. The aim of this study was to identify early prognostic markers of disease resolution by performing a comprehensive analysis of viral and host factors during the natural course of acute HCV infection. Methods: The clinical course of acute hepatitis C was determined in 34 consecutive patients. Epidemiological and virological parameters, as well as cell mediated immunity (CMI) and distribution of human leukocyte antigens (HLA) alleles were analysed. Results: Ten out of 34 patients experienced self-limiting infection, with most resolving patients showing fast kinetics of viral clearance: at least one negative HCV RNA test during this phase predicted a favourable outcome. Among other clinical epidemiological parameters measured, the self-limiting course was significantly associated with higher median peak bilirubin levels at the onset of disease, and with the female sex, but only the latter parameter was independently associated after multivariate analysis. No significant differences between self-limiting or chronic course were observed for the distribution of DRB1 and DQB1 alleles. HCV specific T cell response was more frequently detected during acute HCV infection, than in patients with chronic HCV disease. A significantly broader T cell response was found in patients with self-limiting infection than in those with chronic evolving acute hepatitis C. Conclusion: The results suggest that host related factors, in particular sex and CMI, play a crucial role in the spontaneous clearance of this virus. Most importantly, a negative HCV RNA test and broad CMI within the first month after onset of the symptoms represent very efficacious predictors of viral clearance and could thus be used as criteria in selecting candidates for early antiviral treatment. PMID:15479691

  19. 12 CFR 252.147 - Reports of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Reports of stress test results. 252.147 Section... Covered Companies § 252.147 Reports of stress test results. (a) Reports to the Board of stress test results. (1) A covered company must report the results of the stress test required under § 252.144 to the...

  20. 12 CFR 252.147 - Reports of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Reports of stress test results. 252.147 Section... Covered Companies § 252.147 Reports of stress test results. (a) Reports to the Board of stress test results. (1) A covered company must report the results of the stress test required under section 252.144...

  1. Cryogenic Test Results of Hextek Mirror

    NASA Technical Reports Server (NTRS)

    Hadaway, James; Stahl, H. Philip; Eng, Ron; Hogue, William

    2004-01-01

    A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

  2. MASH TL-3 testing and evaluation of the TXDOT T131RC bridge rail transition.

    DOT National Transportation Integrated Search

    2013-03-01

    This project designed and crash tested a transition design for the Texas Department of Transportation (TxDOT) T131RC Bridge Rail that would meet the strength and safety performance criteria for Test Level 3 of American Association of State Highway Of...

  3. Influence of blood lipids on global coagulation test results.

    PubMed

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon; Kim, Hyun Kyung

    2015-01-01

    High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels.

  4. Drug and alcohol testing results 1998 annual report

    DOT National Transportation Integrated Search

    1999-12-01

    The Drug and Alcohol Testing Results 1998 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1998. The report covers results for the following drug types: marijuana ...

  5. Drug and alcohol testing results 2000 annual report

    DOT National Transportation Integrated Search

    2001-12-01

    The Drug and Alcohol Testing Results 2000 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United State during 2000. The report covers results for the following drug types: marijuana (...

  6. Drug and alcohol testing results 1999 annual report

    DOT National Transportation Integrated Search

    2000-12-01

    The Drug and Alcohol Testing Results 1999 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1999. The report covers results for the following drug types: marijuana ...

  7. Correcting Two-Sample "z" and "t" Tests for Correlation: An Alternative to One-Sample Tests on Difference Scores

    ERIC Educational Resources Information Center

    Zimmerman, Donald W.

    2012-01-01

    In order to circumvent the influence of correlation in paired-samples and repeated measures experimental designs, researchers typically perform a one-sample Student "t" test on difference scores. That procedure entails some loss of power, because it employs N - 1 degrees of freedom instead of the 2N - 2 degrees of freedom of the…

  8. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are... may call the appropriate Science and Technology laboratory for interim or final results prior to...

  9. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  10. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  11. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  12. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  13. 49 CFR 199.229 - Reporting of alcohol testing results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Reporting of alcohol testing results. 199.229... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  14. The X-31A quasi-tailless flight test results

    NASA Technical Reports Server (NTRS)

    Bosworth, John T.; Stoliker, P. C.

    1996-01-01

    A quasi-tailless flight investigation was launched using the X-31A enhanced fighter maneuverability airplane. In-flight simulations were used to assess the effect of partial to total vertical tail removal. The rudder control surface was used to cancel the stabilizing effects of the vertical tail, and yaw thrust vector commands were used to restabilize and control the airplane. The quasi-tailless mode was flown supersonically with gentle maneuvering and subsonically in precision approaches and ground attack profiles. Pilot ratings and a full set of flight test measurements were recorded. This report describes the results obtained and emphasizes the lessons learned from the X-31A flight test experiment. Sensor-related issues and their importance to a quasi-tailless simulation and to ultimately controlling a directionally unstable vehicle are assessed. The X-31A quasi-tailless flight test experiment showed that tailless and reduced tail fighter aircraft are definitely feasible. When the capability is designed into the airplane from the beginning, the benefits have the potential to outweigh the added complexity required.

  15. Preliminary flight-test results of an advanced technology light twin-engine airplane /ATLIT/

    NASA Technical Reports Server (NTRS)

    Holmes, B. J.; Kohlman, D. L.; Crane, H. L.

    1976-01-01

    The present status and flight-test results are presented for the ATLIT airplane. The ATLIT is a Piper PA-34 Seneca I modified by the installation of new wings incorporating the GA(W)-1 (Whitcomb) airfoil, reduced wing area, roll-control spoilers, and full-span Fowler flaps. Flight-test results on stall and spoiler roll characteristics show good agreement with wind-tunnel data. Maximum power-off lift coefficients are greater than 3.0 with flaps deflected 37 deg. With flaps down, spoiler deflections can produce roll helix angles in excess of 0.11 rad. Flight testing is planned to document climb and cruise performance, and supercritical propeller performance and noise characteristics. The airplane is scheduled for testing in the NASA-Langley Research Center Full-Scale Tunnel.

  16. Computation, prediction, and experimental tests of fitness for bacteriophage T7 mutants with permuted genomes

    NASA Astrophysics Data System (ADS)

    Endy, Drew; You, Lingchong; Yin, John; Molineux, Ian J.

    2000-05-01

    We created a simulation based on experimental data from bacteriophage T7 that computes the developmental cycle of the wild-type phage and also of mutants that have an altered genome order. We used the simulation to compute the fitness of more than 105 mutants. We tested these computations by constructing and experimentally characterizing T7 mutants in which we repositioned gene 1, coding for T7 RNA polymerase. Computed protein synthesis rates for ectopic gene 1 strains were in moderate agreement with observed rates. Computed phage-doubling rates were close to observations for two of four strains, but significantly overestimated those of the other two. Computations indicate that the genome organization of wild-type T7 is nearly optimal for growth: only 2.8% of random genome permutations were computed to grow faster, the highest 31% faster, than wild type. Specific discrepancies between computations and observations suggest that a better understanding of the translation efficiency of individual mRNAs and the functions of qualitatively "nonessential" genes will be needed to improve the T7 simulation. In silico representations of biological systems can serve to assess and advance our understanding of the underlying biology. Iteration between computation, prediction, and observation should increase the rate at which biological hypotheses are formulated and tested.

  17. Update on lifetime tests results and analysis carried out on Thales Cryogenics integral coolers (RM family)

    NASA Astrophysics Data System (ADS)

    Cauquil, Jean-Marc; Martin, Jean-Yves; Bruins, Peter; Benschop, A. A. J.

    2003-01-01

    The life time tests realised on the serial production of Rotary Mmonoblock RM2 coolers show a measured MTTF of 4900 hours. The conventional test profile applied to these coolers is representative of operation in typical application. The duration of such life time tests is very long. The results of a design change and its impact on MTTF are available only several months after the assembly of the prototypes. We decided to develop a test method in order to reduce the duration of these life time tests. The principle is to define a test protocol easy to implement, more severe than typical application profile in order to accelerate life time tests. The accelerated test profile was defined and tested successfully. This new technique allows us to reduce life time tests costs and duration and thus the costs involved. As a consequence, we decided to have a screening of our production with this accelerated test. This allows us to master continuously the quality of our serial products and to collect additional data. This paper presents the results of life time tests performed on RM2 coolers according to the conventional and accelerated test profiles as well as the first results on the new RM2 design which show a calculated MTTF of 10000 hours.

  18. Recent results of high p(T) physics at the CDF II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuno, Soushi; /Okayama U.

    2005-02-01

    The Tevatron Run II program has been in progress since 2001. The CDF experiment has accumulated roughly five times as much data as did Run I, with much improved detectors. Preliminary results from the CDF experiment are presented. The authors focus on recent high p{sub T} physics results in the Tevatron Run II program.

  19. Reevaluation of confirmatory tests for human T-cell leukemia virus Type 1 using a luciferase immunoprecipitation system in blood donors.

    PubMed

    Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya

    2015-04-01

    Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.

  20. P- T phase relations of silicic, alkaline, aluminous liquids: new results and applications to mantle melting and metasomatism

    NASA Astrophysics Data System (ADS)

    Draper, David S.; Green, Trevor H.

    1999-07-01

    We report new experimental results obtained under nominally anhydrous conditions at 1.0-1.5 GPa on a synthetic melt whose composition is typical of extreme-composition xenolith glasses. These results demonstrate that part of this extreme compositional range is in equilibrium with a lherzolitic assemblage (olivine, orthopyroxene, and clinopyroxene on the liquidus), extending our earlier findings [D.S. Draper, T.H. Green P- T phase relations of silicic, alkaline, aluminous mantle-xenolith glasses under anhydrous and C-O-H fluid-saturated conditions, J. Petrol. 38 (1997) 1187-1224] showing saturation with harzburgite minerals (olivine and orthopyroxene on the liquidus). The new results strengthen the view that such liquids can readily coexist with upper mantle rocks. Our results also bear on the current debate regarding the nature of low-degree mantle melts between proponents of the diamond-aggregate technique [who argue for comparatively silica- and alkali-rich low-degree melts; e.g., M.B. Baker, M.M. Hirschmann, M.S. Ghiorso, E.M. Stolper, Compositions of near-solidus peridotite melts from experiments and thermodynamic calculations, Nature 375 (1995) 308-311; M.B. Baker, M.M. Hirschmann, L.E. Wasylenki, E.M. Stolper, M.S. Ghiorso, Quest for low-degree mantle melts, Nature 381 (1996) 286] and those favoring the sandwich technique [who question the value of the diamond-aggregate work and argue that near-solidus melts must be nepheline- and olivine-normative; T.J. Falloon, D.H. Green, H.St.C. O'Neill, C.G. Ballhaus, Quest for low-degree mantle melts, Nature 381 (1996) 285; T.J. Falloon, D.H. Green, H.St.C. O'Neill, W.O. Hibberson, Experimental tests of low degree peridotite partial melt compositions: implications for the nature of anhydrous near-solidus peridotite melts at 1 GPa, Earth Planet. Sci. Lett. 152 (1997) 149-162]. Our results support aspects of both views. The sandwich-technique view is supported, for example, because all our liquids coexisting with mantle

  1. [Significance of test results in drug hypersensitivity].

    PubMed

    Wozniak, K D

    1977-12-15

    For the diagnostics of allergic drug reactions in 2,246 patients tests of the skin and in vitro tests were carried out. As causes of the drug rashes analgetics/antipyretics, antibiotics, sulfonamides, local anaesthetics, oral anticonceptive drugs, remedies for the circulation, psychopharmaca and many others have been established. In these cases by means of skin test in 81.5%, by means of the lymphocyte transformation test in 42.9% and by means of the migration inhibition test in 35.9% of the patients a concordant result could be achieved concerning the clinical course of the disease. Relevant to practice from the results must be derived that in sensibilisation proved the avoidance of the pharmacon and of immunochemical related substances is necessary as well as principally in every anamnesis the question for drug tolerances must be asked. The possibility of the development of side effects of pharmaca when these facts are not taken into consideration is emphasized with the help of examples.

  2. Dense grid of narrow bandpass filters for the JST/T250 telescope: summary of results

    NASA Astrophysics Data System (ADS)

    Brauneck, Ulf; Sprengard, Ruediger; Bourquin, Sebastien; Marín-Franch, Antonio

    2018-01-01

    On the Javalambre mountain in Spain, the Centro de Estudios de Fisica del Cosmos de Aragon has setup two telescopes, the JST/T250 and the JAST/T80. The JAST/T80 telescope integrates T80Cam, a large format, single CCD camera while the JST/T250 will mount the JPCam instrument, a 1.2Gpix camera equipped with a 14-CCD mosaic using the new large format e2v 9.2k×9.2k 10-μm pixel detectors. Both T80Cam and JPCam integrate a large number of filters in dimensions of 106.8×106.8 mm2 and 101.7×95.5 mm2, respectively. For this instrument, SCHOTT manufactured 56 specially designed steep edged bandpass interference filters, which were recently completed. The filter set consists of bandpass filters in the range between 348.5 and 910 nm and a longpass filter at 915 nm. Most of the filters have full-width at half-maximum (FWHM) of 14.5 nm and a blocking between 250 and 1050 nm with optical density of OD5. Absorptive color glass substrates in combination with interference filters were used to minimize residual reflection in order to avoid ghost images. In spite of containing absorptive elements, the filters show the maximum possible transmission. This was achieved by using magnetron sputtering for the filter coating process. The most important requirement for the continuous photometric survey is the tight tolerancing of the central wavelengths and FWHM of the filters. This insures each bandpass has a defined overlap with its neighbors. A high image quality required a low transmitted wavefront error (<λ/4 locally and <λ/2 on the whole aperture), which was achieved even by combining two or three substrates. We report on the spectral and interferometric results measured on the whole set of filters.

  3. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  4. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  5. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  6. 7 CFR 91.24 - Reports of test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Reports of test results. 91.24 Section 91.24... SERVICES AND GENERAL INFORMATION Reporting § 91.24 Reports of test results. (a) Results of analyses are provided, in writing, by facsimile, by e-mail or other electronic means to the applicant. (b) Results of...

  7. Outcomes in Women With Cytology Showing Atypical Squamous Cells of Undetermined Significance With vs Without Human Papillomavirus Testing

    PubMed Central

    Cuzick, Jack; Myers, Orrin; Lee, Ji-Hyun; Shi, Yang; Gage, Julia C.; Hunt, William C.; Robertson, Michael

    2017-01-01

    Importance Little is known about the long-term yield of high-grade cervical intraepithelial neoplasia (CIN) and the influence on biopsy and treatment rates of human papillomavirus (HPV) triage of cytology showing atypical squamous cells of undetermined significance (hereafter ASC-US cytology). Objective To examine 5-year outcomes after ASC-US cytology with vs without HPV testing. Design, Setting, and Participants In this observational study, all cervical cytology and HPV testing reports from January 1, 2007, to December 31, 2012, were obtained for women throughout New Mexico and linked to pathology reports. The dates of the analysis were May 4, 2015, to January 13, 2017. Main Outcomes and Measures Influence of HPV testing on disease yield, time to histologically confirmed disease, and biopsy or loop electrosurgical excision procedure rates. Results A total of 457 317 women (mean [SD] age, 39.8 [12.5] years) with a screening test were recorded between 2008 and 2012, and 20 677 (4.5%) of the first cytology results per woman were reported as ASC-US. CIN grade 3 or more severe (CIN3+) lesions were detected in 2.49% of women with HPV testing vs 2.15% of women without HPV testing (P = .23). Time to CIN3+ detection was much shorter in those with HPV testing vs those without testing (median, 103 vs 393 days; P < .001). CIN grade 1 was detected in 11.6% of women with HPV testing vs 6.6% without testing (relative risk, 1.76; 95% CI, 1.56-2.00; P < .001). Loop electrosurgical excision procedure rates within 5 years were 20.0% higher in those who underwent HPV testing, resulting in more CIN2+ and CIN3+ detection. Conclusions and Relevance Human papillomavirus testing led to faster and more complete diagnosis of cervical disease, but 55.8% more biopsies and 20.0% more loop electrosurgical excision procedures were performed. In those tested, virtually all high-grade disease occurred in the 43.1% of women who were HPV positive, allowing clinical resources to be

  8. Results of patch testing with lavender oil in Japan.

    PubMed

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or <+ at 1 day after removal. The positivity rate of lavender oil was 3.7% (0-13.9%) during the 9-year period from 1990 to 1998. The positivity rate of lavender oil increased suddenly in 1997. Recently, in Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  9. Natural T Cell–mediated Protection against Seasonal and Pandemic Influenza. Results of the Flu Watch Cohort Study

    PubMed Central

    Wang, Lili; Goonetilleke, Nilu; Fragaszy, Ellen B.; Bermingham, Alison; Copas, Andrew; Dukes, Oliver; Millett, Elizabeth R. C.; Nazareth, Irwin; Nguyen-Van-Tam, Jonathan S.; Watson, John M.; Zambon, Maria; Johnson, Anne M.; McMichael, Andrew J.

    2015-01-01

    Rationale: A high proportion of influenza infections are asymptomatic. Animal and human challenge studies and observational studies suggest T cells protect against disease among those infected, but the impact of T-cell immunity at the population level is unknown. Objectives: To investigate whether naturally preexisting T-cell responses targeting highly conserved internal influenza proteins could provide cross-protective immunity against pandemic and seasonal influenza. Methods: We quantified influenza A(H3N2) virus–specific T cells in a population cohort during seasonal and pandemic periods between 2006 and 2010. Follow-up included paired serology, symptom reporting, and polymerase chain reaction (PCR) investigation of symptomatic cases. Measurements and Main Results: A total of 1,414 unvaccinated individuals had baseline T-cell measurements (1,703 participant observation sets). T-cell responses to A(H3N2) virus nucleoprotein (NP) dominated and strongly cross-reacted with A(H1N1)pdm09 NP (P < 0.001) in participants lacking antibody to A(H1N1)pdm09. Comparison of paired preseason and post-season sera (1,431 sets) showed 205 (14%) had evidence of infection based on fourfold influenza antibody titer rises. The presence of NP-specific T cells before exposure to virus correlated with less symptomatic, PCR-positive influenza A (overall adjusted odds ratio, 0.27; 95% confidence interval, 0.11–0.68; P = 0.005, during pandemic [P = 0.047] and seasonal [P = 0.049] periods). Protection was independent of baseline antibodies. Influenza-specific T-cell responses were detected in 43%, indicating a substantial population impact. Conclusions: Naturally occurring cross-protective T-cell immunity protects against symptomatic PCR-confirmed disease in those with evidence of infection and helps to explain why many infections do not cause symptoms. Vaccines stimulating T cells may provide important cross-protective immunity. PMID:25844934

  10. Fiber-optic sensor demonstrator (FSD) preliminary test results on PROBA-2

    NASA Astrophysics Data System (ADS)

    Kruzelecky, Roman V.; Zou, Jing; Haddad, Emile; Jamroz, Wes; Ricci, Francesco; Edwards, Eric; McKenzie, Iain; Vuilleumier, Pierrik

    2017-11-01

    Fiber Sensor Demonstrator (FSD) developed by MPB Communications (MPBC) is the first demonstration of a full fiber-optic sensor network in the space environment on a satellite. FSD has been launched on ESA's Proba-2 satellite in November 2009. FSD contains twelve temperature sensors to measure the temperature at different locations in the satellite, and one High-Temperature sensor to measure the transient high temperature in the thruster, as well as one pressure sensor to measure the xenon tank pressure. First set of on-orbit test data were obtained in January 2010. The FSD unit successfully established the communication with Proba-2. The temperature of FSD unit was also acquired through a AD590 sensor inside the unit. The measurements of all the optical fiber sensor lines will be evaluated after the testing results obtained. The FSD contains twelve specially-packaged FBG temperature sensors to measure the temperature at different locations in the propulsion system and the spacecraft over the range of -60°C to +120°C. A high-temperature sensor is provided to measure the transient temperature response of the thruster to beyond 350°C. There is also an innovative P/T sensor that provides both temperature and pressure measurements of the Xe propellant tank. The preliminary data of on-orbit functional testing and temperature measurements are provided mainly in Section 6.

  11. Supersonic Panel Flutter Test Results for Flat Fiber-Glass Sandwich Panels with Foamed Cores

    NASA Technical Reports Server (NTRS)

    Tuovila, W. J.; Presnell, John G., Jr.

    1961-01-01

    Flutter tests have been made on flat panels having a 1/4 inch-thick plastic-foam core covered with thin fiber-glass laminates. The testing was done in the Langley Unitary Plan wind tunnel at Mach numbers from 1.76 t o 2.87. The flutter boundary for these panels was found to be near the flutter boundary of thin metal panels when compared on the basis of an equivalent panel stiffness. The results also demonstrated that the depth of the cavity behind the panel has a pronounced influence on flutter. Changing the cavity depth from 1 1/2 inches to 1/2 inch reduced the dynamic pressure at start of flutter by 40 percent. No flutter was obtained when the spacers on the back of the panel were against the bottom of the cavity.

  12. An assessment of wind tunnel test data on flexible thermal protection materials and results of new fatigue tests of threads

    NASA Technical Reports Server (NTRS)

    Coe, Charles F.

    1985-01-01

    Advanced Flexible Reusable Surface Insulation (AFRSI) was developed as a replacement for the low-temperature (white) tiles on the Space Shuttle. The first use of the AFRSI for an Orbiter flight was on the OMS POD of Orbiter (OV-099) for STS-6. Post flight examination after STS-6 showed that damage had occurred to the AFRSI during flight. The failure anomaly between previous wind-tunnel tests and STS-6 prompted a series of additional wind tunnel tests to gain an insight as to the cause of the failure. An assessment of all the past STS-6 wind tunnel tests pointed out the sensitivity of the test results to scaling of dynamic loads due to the difference of boundary layer thickness, and the material properties as a result of exposure to heating. The thread component of the AFRSI was exposed to fatigue testing using an apparatus that applied pulsating aerodynamic loads on the threads similar to the loads caused by an oscillating shock. Comparison of the mean values of the number-of-cycles to failure showed that the history of the thread was the major factor in its performance. The thread and the wind tunnel data suggests a mechanism of failure for the AFRSI.

  13. 3T diffusion-weighted MRI of the thyroid gland with reduced distortion: preliminary results

    PubMed Central

    Nagala, S; Priest, A N; McLean, M A; Jani, P; Graves, M J

    2013-01-01

    Objective: Single-shot diffusion-weighted (DW) echo planar imaging (EPI), which is commonly used for imaging the thyroid, is characterised by severe blurring and distortion. The objectives of this work were: 1, to show that a reduced-field of view (r-FOV) DW EPI technique can improve image quality; and 2, to investigate the effect of different reconstruction strategies on the resulting apparent diffusion coefficients (ADCs). Methods: We implemented a single-shot, r-FOV DW EPI technique with a two-dimensional radiofrequency excitation pulse for DW imaging of the thyroid at 3T. Images were reconstructed using root sum of squares (SOS) and an optimal-B1 reconstruction (OBR). Phantom and in vivo experiments were performed to compare r-FOV and conventional full-FOV DW EPI with root SOS and OBR. Results: r-FOV with OBR substantially improved image quality at 3T. In phantoms, r-FOV gave more accurate ADCs than full-FOV. In vivo r-FOV always gave lower ADC values with respect to the full-FOV technique irrespective of the reconstruction used and whether only two or multiple b-values were used to compute the ADCs. Conclusion: r-FOV DW EPI can reduce image blurring and distortion at the expense of a low signal-to-noise ratio. OBR is a promising reconstruction technique for accurate ADC measurements in lower signal-to-noise ratio regimes, although further studies are needed to characterise its performance. Advances in knowledge: DW imaging of the thyroid at 3T could potentially benefit from r-FOV acquisition strategies, such as the r-FOV DW EPI technique proposed in this paper. PMID:23770539

  14. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  15. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  16. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  17. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  18. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  19. 12 CFR 252.156 - Reports of stress test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 4 2013-01-01 2013-01-01 false Reports of stress test results. 252.156 Section....156 Reports of stress test results. (a) Reports to the Board of stress test results—(1) Savings and... report the results of the stress test to the Board by January 5 of each calendar year in the manner and...

  20. Older people experiencing homelessness show marked impairment on tests of frontal lobe function.

    PubMed

    Rogoz, Astrid; Burke, David

    2016-03-01

    Reported rates of mild and moderate cognitive impairment in older people experiencing homelessness range from 5-80%. The objective of this study was to determine the prevalence and characteristics of cognitive impairment in older people experiencing homelessness in the inner city of Sydney, Australia. Men and women experiencing homelessness aged 45 years and over in the inner city were screened for cognitive impairment. Participants who scored 26 or below on the mini-mental state examination and/or were impaired on any one of the clock-drawing test, the verbal fluency test and the trail-making test, part B were then assessed with a semi-structured interview, including the 21-item Depression Anxiety Stress Scale and the 12-item General Health Questionnaire. Screening of 144 men and 27 women aged between 45 years and 93 years identified cognitive impairment in 78%. Subsequently, high rates of mental and physical illness were identified, and 75% of subjects who were cognitively impaired performed poorly on frontal lobe tests. The trail-making test, part B was the most sensitive measure of frontal function. This study demonstrated that a large majority of older people experiencing homelessness, in the inner city of a high-income country, showed impairment on tests of frontal lobe function, a finding that could have significant implications for any medical or psychosocial intervention. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Vitrigel-eye irritancy test method using HCE-T cells.

    PubMed

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2013-10-01

    We previously reported that the time-dependent relative changes of transepithelial electrical resistance (TEER) after exposing four different chemicals to a human corneal epithelium (HCE) model were well correlated to the potential of ocular irritancy. Meanwhile, we recently developed a collagen vitrigel membrane (CVM) chamber possessing a scaffold composed of high-density collagen fibrils equivalent to connective tissues in vivo as a three-dimensional culture tool. The CVM chamber is useful for biomedical assays and immunohistology using cryosections that are inappropriate to be performed using the conventional Millicell chamber with a polyethylene terephthalate membrane. In this study, we aimed to develop a new eye irritancy test (EIT) method called "Vitrigel-EIT method" that can facilitate to briefly and accurately estimate the widespread irritancy of test chemicals by applying the TEER assay system to a HCE model fabricated in the CVM chamber. HCE-T cells (a HCE-derived cell strain) were cultured in the CVM chamber for 6 days, and consequently, the Vitrigel-HCE model possessing the following characteristics of HCE in vivo was formed: six cell layers with specific protein expressions and their barrier function. Time-dependent profiles of TEER values after exposing 30 test chemicals to the HCE model were converted into the scores of three indexes (time lag, intensity, and plateau level), and each chemical was successfully classified into irritant or nonirritant category by utilizing the criteria for the indexes, resulting in the excellent correlation with Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification (sensitivity: 100%, specificity: 75%, accuracy: 90%). These data suggest that the widespread eye irritancy of chemicals can be predicted without false negatives by the Vitrigel-EIT method. Interestingly, the disruption of tight junctions was immunohistologically observed after exposing not only irritants but also three

  2. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    PubMed Central

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong

    2017-01-01

    Purpose False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. Materials and Methods A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Results Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24–3.40; p<0.001). Conclusion Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs. PMID:27873508

  3. Chemical control of blister rust on sugar pine...two fungicides show promise in California tests

    Treesearch

    Clarence R. Quick

    1967-01-01

    Among several fungicides tested, Phytoactin L-340 and Dowicide 1 (o-phenylphenol) showed the most promise for systemic chemical control of blister rust on sugar pine in northern California. The trials included 22 tests on 224 sugar pines: five with Acti-dione BR (cycloheximide), one each with five common chemical fungicides,and 12 with phytoactin. Apparent...

  4. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    PubMed

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; p<0.001). Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  5. The meaning of diagnostic test results: a spreadsheet for swift data analysis.

    PubMed

    Maceneaney, P M; Malone, D E

    2000-03-01

    To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. Microsoft Excel(TM)was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. This spreadsheet can be used on desktop and palmtop computers. The MS Excel(TM)version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. Copyright 2000 The Royal College of Radiologists.

  6. Analysis of Factors Influencing Measurement Accuracy of Al Alloy Tensile Test Results

    NASA Astrophysics Data System (ADS)

    Podgornik, Bojan; Žužek, Borut; Sedlaček, Marko; Kevorkijan, Varužan; Hostej, Boris

    2016-02-01

    In order to properly use materials in design, a complete understanding of and information on their mechanical properties, such as yield and ultimate tensile strength must be obtained. Furthermore, as the design of automotive parts is constantly pushed toward higher limits, excessive measuring uncertainty can lead to unexpected premature failure of the component, thus requiring reliable determination of material properties with low uncertainty. The aim of the present work was to evaluate the effect of different metrology factors, including the number of tested samples, specimens machining and surface quality, specimens input diameter, type of testing and human error on the tensile test results and measurement uncertainty when performed on 2xxx series Al alloy. Results show that the most significant contribution to measurement uncertainty comes from the number of samples tested, which can even exceed 1 %. Furthermore, moving from experimental laboratory conditions to very intense industrial environment further amplifies measurement uncertainty, where even if using automated systems human error cannot be neglected.

  7. Effect of Localized Corrosion on Fatigue-Crack Growth in 2524-T3 and 2198-T851 Aluminum Alloys Used as Aircraft Materials

    NASA Astrophysics Data System (ADS)

    Moreto, J. A.; Broday, E. E.; Rossino, L. S.; Fernandes, J. C. S.; Bose Filho, W. W.

    2018-03-01

    Corrosion and fatigue of aluminum alloys are major issues for the in-service life assessment of aircraft structures and for the management of aging air fleets. The aim of this work was to evaluate the effect of localized corrosion on fatigue crack growth (FCG) resistance of the AA2198-T851 Al-Li alloy (Solution Heat Treated, Cold Worked, and Artificially Aged), comparing it with the FCG resistance of AA2524-T3 (Solution Heat Treated and Cold Worked), considering the effect of seawater fog environment. Before fatigue tests, the corrosion behavior of 2198-T851 and 2524-T3 aluminum alloys was verified using open circuit potential and potentiodynamic polarization techniques. Fatigue in air and corrosion fatigue tests were performed applying a stress ratio (R) of 0.1, 15 Hz (air) and 0.1 Hz (seawater fog) frequencies, using a sinusoidal waveform in all cases. The results showed that the localized characteristics of the 2198-T851 and 2524-T3 aluminum alloys are essentially related to the existence of intermetallic compounds, which, due to their different nature, may be cathodic or anodic in relation to the aluminum matrix. The corrosive medium has affected the FCG rate of both aluminum alloys, in a quite similar way.

  8. Cassini RTG acceptance test results and RTG performance on Galileo and Ulysses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, C.E.; Klee, P.M.

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, properties (weight and c.g.) and thermal vacuum test. This paper presents The thermal vacuum test results. Three RTGs are to be used, F-2, F-6, and F-7. F-5 is tile back-up RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at die Mound Laboratory facility met allmore » specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on than tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also showing. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over five percent are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission.« less

  9. Cassini RTG Acceptance Test Results and RTG Performance on Galileo and Ulysses

    DOE R&D Accomplishments Database

    Kelly, C. E.; Klee, P. M.

    1997-06-01

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, properties (weight and c.g.) and thermal vacuum test. This paper presents The thermal vacuum test results. Three RTGs are to be used, F 2, F 6, and F 7. F 5 is tile back up RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at die Mound Laboratory facility met all specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on than tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also showing. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over five percent are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission.

  10. [USE OF QuantiFERON-TB Gold in Tube AND T-SPOT.TB FOR DIAGNOSING PATIENTS WITH SUSPECTED PULMONARY TUBERCULOSIS].

    PubMed

    Okimoto, Niro; Kurihara, Takeyuki; Miyashita, Naoyuki

    2016-04-01

    We analyzed the use of QFT-TB Gold in Tube and T-SPOT.TB in diagnosing patients with suspected pulmonary tuberculosis. We evaluated 122 patients with suspected pulmonary tuberculosis (where chest X-ray showed consolidation or. tumor shadow in predilection sites of pulmonary tuberculosis and through contact investigation). QFT-TB Gold and T-SPOT.TB were performed for all the patients. The positive response rate and history of pulmonary tuberculosis in patients who showed positive results for the tests were evaluated. Ninteen patients showed positive results for QFT-TB Gold, and 9, for T-SPOT.TB. Four patients showed positive results for QFT-TB Gold, and 3, for T-SPOT.TB in 4 patients with active tuberculosis. The patients without active tuberculosis whose IGRAs were positive (old pulmonary tuberculosis, Mycobacterium avium cmplex, pneumonia, lung cancer, pulmonary sequestration, bronchiectasis) had a past history of pulmonary tuberculosis. The positive result rate of QFT?-TB Gold was higher than that of T-SPOT.TB in the subjects with suspected pulmonary tuberculosis. We think that QFT-TB Gold reflected the past history of pulmonary tuberculosis.

  11. Effects of different centrifugation conditions on clinical chemistry and Immunology test results

    PubMed Central

    2011-01-01

    Background The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. Methods We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One) were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Results Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p < 0.05, which was less than the expected 5%. This suggests that the outliers are the result of random variation and the large number of statistical tests performed. Further, we found that our data are sufficient not to miss a biased test (beta error) with a probability of 0.10 to 0.05 in most parameters. Conclusion A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study. PMID:21569233

  12. White matter fiber-based analysis of T1w/T2w ratio map

    NASA Astrophysics Data System (ADS)

    Chen, Haiwei; Budin, Francois; Noel, Jean; Prieto, Juan Carlos; Gilmore, John; Rasmussen, Jerod; Wadhwa, Pathik D.; Entringer, Sonja; Buss, Claudia; Styner, Martin

    2017-02-01

    Purpose: To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. Background: The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. Methods: We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. Results: We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development.

  13. A T3 and T7 Recombinant Phage Acquires Efficient Adsorption and a Broader Host Range

    PubMed Central

    Lin, Tiao-Yin; Lo, Yi-Haw; Tseng, Pin-Wei; Chang, Shun-Fu; Lin, Yann-Tsyr; Chen, Ton-Seng

    2012-01-01

    It is usually thought that bacteriophage T7 is female specific, while phage T3 can propagate on male and female Escherichia coli. We found that the growth patterns of phages T7M and T3 do not match the above characteristics, instead showing strain dependent male exclusion. Furthermore, a T3/7 hybrid phage exhibits a broader host range relative to that of T3, T7, as well as T7M, and is able to overcome the male exclusion. The T7M sequence closely resembles that of T3. T3/7 is essentially T3 based, but a DNA fragment containing part of the tail fiber gene 17 is replaced by the T7 sequence. T3 displays inferior adsorption to strains tested herein compared to T7. The T3 and T7 recombinant phage carries altered tail fibers and acquires better adsorption efficiency than T3. How phages T3 and T7 recombine was previously unclear. This study is the first to show that recombination can occur accurately within only 8 base-pair homology, where four-way junction structures are identified. Genomic recombination models based on endonuclease I cleavages at equivalent and nonequivalent sites followed by strand annealing are proposed. Retention of pseudo-palindromes can increase recombination frequency for reviving under stress. PMID:22347414

  14. A T3 and T7 recombinant phage acquires efficient adsorption and a broader host range.

    PubMed

    Lin, Tiao-Yin; Lo, Yi-Haw; Tseng, Pin-Wei; Chang, Shun-Fu; Lin, Yann-Tsyr; Chen, Ton-Seng

    2012-01-01

    It is usually thought that bacteriophage T7 is female specific, while phage T3 can propagate on male and female Escherichia coli. We found that the growth patterns of phages T7M and T3 do not match the above characteristics, instead showing strain dependent male exclusion. Furthermore, a T3/7 hybrid phage exhibits a broader host range relative to that of T3, T7, as well as T7M, and is able to overcome the male exclusion. The T7M sequence closely resembles that of T3. T3/7 is essentially T3 based, but a DNA fragment containing part of the tail fiber gene 17 is replaced by the T7 sequence. T3 displays inferior adsorption to strains tested herein compared to T7. The T3 and T7 recombinant phage carries altered tail fibers and acquires better adsorption efficiency than T3. How phages T3 and T7 recombine was previously unclear. This study is the first to show that recombination can occur accurately within only 8 base-pair homology, where four-way junction structures are identified. Genomic recombination models based on endonuclease I cleavages at equivalent and nonequivalent sites followed by strand annealing are proposed. Retention of pseudo-palindromes can increase recombination frequency for reviving under stress.

  15. Test-retest reliability of prefrontal transcranial Direct Current Stimulation (tDCS) effects on functional MRI connectivity in healthy subjects.

    PubMed

    Wörsching, Jana; Padberg, Frank; Helbich, Konstantin; Hasan, Alkomiet; Koch, Lena; Goerigk, Stephan; Stoecklein, Sophia; Ertl-Wagner, Birgit; Keeser, Daniel

    2017-07-15

    Transcranial Direct Current Stimulation (tDCS) of the prefrontal cortex (PFC) can be used for probing functional brain connectivity and meets general interest as novel therapeutic intervention in psychiatric and neurological disorders. Along with a more extensive use, it is important to understand the interplay between neural systems and stimulation protocols requiring basic methodological work. Here, we examined the test-retest (TRT) characteristics of tDCS-induced modulations in resting-state functional-connectivity MRI (RS fcMRI). Twenty healthy subjects received 20minutes of either active or sham tDCS of the dorsolateral PFC (2mA, anode over F3 and cathode over F4, international 10-20 system), preceded and ensued by a RS fcMRI (10minutes each). All subject underwent three tDCS sessions with one-week intervals in between. Effects of tDCS on RS fcMRI were determined at an individual as well as at a group level using both ROI-based and independent-component analyses (ICA). To evaluate the TRT reliability of individual active-tDCS and sham effects on RS fcMRI, voxel-wise intra-class correlation coefficients (ICC) of post-tDCS maps between testing sessions were calculated. For both approaches, results revealed low reliability of RS fcMRI after active tDCS (ICC (2,1) = -0.09 - 0.16). Reliability of RS fcMRI (baselines only) was low to moderate for ROI-derived (ICC (2,1) = 0.13 - 0.50) and low for ICA-derived connectivity (ICC (2,1) = 0.19 - 0.34). Thus, for ROI-based analyses, the distribution of voxel-wise ICC was shifted to lower TRT reliability after active, but not after sham tDCS, for which the distribution was similar to baseline. The intra-individual variation observed here resembles variability of tDCS effects in motor regions and may be one reason why in this study robust tDCS effects at a group level were missing. The data can be used for appropriately designing large scale studies investigating methodological issues such as sources of variability and

  16. Recent Results from the T2K Experiment

    NASA Astrophysics Data System (ADS)

    Abe, K.; Abgrall, N.; Aihara, H.; Akiri, T.; Andreopoulos, C.; Aoki, S.; Ariga, A.; Ariga, T.; Assylbekov, S.; Autiero, D.; Barbi, M.; Barker, G. J.; Barr, G.; Bass, M.; Batkiewicz, M.; Bay, F.; Bentham, S. W.; Berardi, V.; Berger, B. E.; Berkman, S.; Bertram, I.; Bhadra, S.; Blaszczyk, F. D. M.; Blondel, A.; Bojechko, C.; Boyd, S. B.; Brailsford, D.; Bravar, A.; Bronner, C.; Buchanan, N.; Calland, R. G.; Caravaca Rodríguez, J.; Cartwright, S. L.; Castillo, R.; Catanesi, M. G.; Cervera, A.; Cherdack, D.; Christodoulou, G.; Clifton, A.; Coleman, J.; Coleman, S. J.; Collazuol, G.; Connolly, K.; Cremonesi, L.; Curioni, A.; Dabrowska, A.; Danko, I.; Das, R.; Davis, S.; de Perio, P.; De Rosa, G.; Dealtry, T.; Dennis, S. R.; Densham, C.; Di Lodovico, F.; Di Luise, S.; Drapier, O.; Duboyski, T.; Dufour, F.; Dumarchez, J.; Dytman, S.; Dziewiecki, M.; Emery, S.; Ereditato, A.; Escudero, L.; Finch, A. J.; Frank, E.; Friend, M.; Fujii, Y.; Fukuda, Y.; Furmanski, A. P.; Galymov, V.; Gaudin, A.; Giffin, S.; Giganti, C.; Gilje, K.; Golan, T.; Gomez-Cadenas, J. J.; Gonin, M.; Grant, N.; Gudin, D.; Hadley, D. R.; Haesler, A.; Haigh, M. D.; Hamilton, P.; Hansen, D.; Hara, T.; Hartz, M.; Hasegawa, T.; Hastings, N. C.; Hayato, Y.; Hearty, C.; Helmer, R. L.; Hierholzer, M.; Hignight, J.; Hillairet, A.; Himmel, A.; Hiraki, T.; Hirota, S.; Holeczek, J.; Horikawa, S.; Huang, K.; Ichikawa, A. K.; Ieki, K.; Ieva, M.; Ikeda, M.; Imber, J.; Insler, J.; Irvine, T. J.; Ishida, T.; Ishii, T.; Ives, S. J.; Iyogi, K.; Izmaylov, A.; Jacob, A.; Jamieson, B.; Johnson, R. A.; Jo, J. H.; Jonsson, P.; Joo, K. K.; Jung, C. K.; Kaboth, A. C.; Kajita, T.; Kakuno, H.; Kameda, J.; Kanazawa, Y.; Karlen, D.; Karpikov, I.; Kearns, E.; Khabibullin, M.; Khotjantsev, A.; Kielczewska, D.; Kikawa, T.; Kilinski, A.; Kim, J.; Kim, S. B.; Kisiel, J.; Kitching, P.; Kobayashi, T.; Kogan, G.; Kolaceke, A.; Konaka, A.; Kormos, L. L.; Korzenev, A.; Koseki, K.; Koshio, Y.; Kreslo, I.; Kropp, W.; Kubo, H.; Kudenko, Y.; Kumaratunga, S.; Kurjata, R.; Kutter, T.; Lagoda, J.; Laihem, K.; Laveder, M.; Lawe, M.; Lazos, M.; Lee, K. P.; Licciardi, C.; Lim, I. T.; Lindner, T.; Lister, C.; Litchfield, R. P.; Longhin, A.; Lopez, G. D.; Ludovici, L.; Macaire, M.; Magaletti, L.; Mahn, K.; Malek, M.; Manly, S.; Marino, A. D.; Marteau, J.; Martin, J. F.; Maruyama, T.; Marzec, J.; Masliah, P.; Mathie, E. L.; Matveev, V.; Mavrokoridis, K.; Mazzucato, E.; McCauley, N.; McFarland, K. S.; McGrew, C.; Metelko, C.; Mijakowski, P.; Miller, C. A.; Minamino, A.; Mineev, O.; Mine, S.; Missert, A.; Miura, M.; Monfregola, L.; Moriyama, S.; Mueller, Th. A.; Murakami, A.; Murdoch, M.; Murphy, S.; Myslik, J.; Nagasaki, T.; Nakadaira, T.; Nakahata, M.; Nakai, T.; Nakamura, K.; Nakayama, S.; Nakaya, T.; Nakayoshi, K.; Nielsen, C.; Nirkko, M.; Nishikawa, K.; Nishimura, Y.; O'Keeffe, H. M.; Ohta, R.; Okumura, K.; Okusawa, T.; Oryszczak, W.; Oser, S. M.; Otani, M.; Owen, R. A.; Oyama, Y.; Pac, M. Y.; Palladino, V.; Paolone, V.; Payne, D.; Pearce, G. F.; Perevozchikov, O.; Perkin, J. D.; Petrov, Y.; Pinzon Guerra, E. S.; Pistillo, C.; Plonski, P.; Poplawska, E.; Popov, B.; Posiadala, M.; Poutissou, J.-M.; Poutissou, R.; Przewlocki, P.; Quilain, B.; Radicioni, E.; Ratoff, P. N.; Ravonel, M.; Rayner, M. A. M.; Redij, A.; Reeves, M.; Reinherz-Aronis, E.; Retiere, F.; Robert, A.; Rodrigues, P. A.; Rondio, E.; Roth, S.; Rubbia, A.; Ruterbories, D.; Sacco, R.; Sakashita, K.; Sánchez, F.; Scantamburlo, E.; Scholberg, K.; Schwehr, J.; Scott, M.; Seiya, Y.; Sekiguchi, T.; Sekiya, H.; Sgalaberna, D.; Shiozawa, M.; Short, S.; Shustrov, Y.; Sinclair, P.; Smith, B.; Smith, R. J.; Smy, M.; Sobczyk, J. T.; Sobel, H.; Sorel, M.; Southwell, L.; Stamoulis, P.; Steinmann, J.; Still, B.; Suda, Y.; Suzuki, A.; Suzuki, K.; Suzuki, S. Y.; Suzuki, Y.; Szeglowski, T.; Tacik, R.; Tada, M.; Takahashi, S.; Takeda, A.; Takeuchi, Y.; Tanaka, H. A.; Tanaka, M. M.; Taylor, I. J.; Terhorst, D.; Terri, R.; Thompson, L. F.; Thorley, A.; Tobayama, S.; Toki, W.; Tomura, T.; Totsuka, Y.; Touramanis, C.; Tsukamoto, T.; Tzanov, M.; Uchida, Y.; Ueno, K.; Vacheret, A.; Vagins, M.; Vasseur, G.; Wachala, T.; Waldron, A. V.; Walter, C. W.; Wark, D.; Wascko, M. O.; Weber, A.; Wendell, R.; Wilkes, R. J.; Wilking, M. J.; Wilkinson, C.; Williamson, Z.; Wilson, J. R.; Wilson, R. J.; Wongjirad, T.; Yamada, Y.; Yamamoto, K.; Yanagisawa, C.; Yen, S.; Yershov, N.; Yokoyama, M.; Yuan, T.; Zalewska, A.; Zalipska, J.; Zambelli, L.; Zaremba, K.; Ziembicki, M.; Zimmerman, E. D.; Zito, M.; Żmuda, J.

    2014-01-01

    The Tokai to Kamioka (T2K) experiment studies neutrino oscillations using a beam of muon neutrinos produced by an accelerator. The neutrinos travel from J-PARC on the east coast of Japan and are detected 295 kilometers further away in the Super-Kamiokande detector. A complex of near detectors located 280 meters away from the neutrino production target is used to better characterize the neutrino beam and reduce systematic uncertainties. The experiment aims at measuring electronic neutrino appearance (νμ →νe oscillation) to measure the neutrino mixing angle θ13, and muon neutrino disappearance to measure the neutrino mixing angle θ23 and mass splitting | Δ m322 |. We report here electron neutrino appearance results using three years of data, recorded until the 2012 summer, as well as muon neutrino disappearance results based on the data coming from the first two years of the experiment.

  17. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    PubMed

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  18. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  19. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  20. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  1. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  2. 49 CFR 199.109 - Review of drug testing results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  3. Proof test and fatigue crack growth modeling on 2024-T3 aluminum alloy

    NASA Technical Reports Server (NTRS)

    Newman, J. C., Jr.; Poe, C. C., Jr.; Dawicke, D. S.

    1990-01-01

    Pressure proof testing of aircraft fuselage structures has been suggested as a means of screening critical crack sizes and of extending their useful life. The objective of this paper is to study the proof-test concept and to model the crack-growth process on a ductile material. Simulated proof and operational fatigue life tests have been conducted on cracked panels made of 2024-T3 aluminum alloy sheet material. A fatigue crack-closure model was modified to simulate the proof test and operational fatigue cycling. Using crack-growth rate and resistance-curve data, the model was able to predict crack growth during and after the proof load. These tests and analyses indicate that the proof test increases fatigue life; but the beneficial life, after a 1.33 or 1.5 proof, was less than a few hundred cycles.

  4. What Do the Results of Genetic Tests Mean?

    MedlinePlus

    ... does it take to get the results? Will health insurance cover the costs of genetic testing? What are the benefits of genetic testing? What are the risks and limitations of genetic testing? What is genetic ...

  5. Recent flight-test results of optical airdata techniques

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.

    1993-01-01

    Optical techniques for measuring airdata parameters were demonstrated with promising results on high performance fighter aircraft. These systems can measure the airspeed vector, and some are not as dependent on special in-flight calibration processes as current systems. Optical concepts for measuring freestream static temperature and density are feasible for in-flight applications. The best feature of these concepts is that the air data measurements are obtained nonintrusively, and for the most part well into the freestream region of the flow field about the aircraft. Current requirements for measuring air data at high angle of attack, and future need to measure the same information at hypersonic flight conditions place strains on existing techniques. Optical technology advances show outstanding potential for application in future programs and promise to make common use of optical concepts a reality. Results from several flight-test programs are summarized, and the technology advances required to make optical airdata techniques practical are identified.

  6. On determining the most appropriate test cut-off value: the case of tests with continuous results

    PubMed Central

    Habibzadeh, Parham; Yadollahie, Mahboobeh

    2016-01-01

    There are several criteria for determination of the most appropriate cut-off value in a diagnostic test with continuous results. Mostly based on receiver operating characteristic (ROC) analysis, there are various methods to determine the test cut-off value. The most common criteria are the point on ROC curve where the sensitivity and specificity of the test are equal; the point on the curve with minimum distance from the left-upper corner of the unit square; and the point where the Youden’s index is maximum. There are also methods mainly based on Bayesian decision analysis. Herein, we show that a proposed method that maximizes the weighted number needed to misdiagnose, an index of diagnostic test effectiveness we previously proposed, is the most appropriate technique compared to the aforementioned ones. For determination of the cut-off value, we need to know the pretest probability of the disease of interest as well as the costs incurred by misdiagnosis. This means that even for a certain diagnostic test, the cut-off value is not universal and should be determined for each region and for each disease condition. PMID:27812299

  7. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  8. Results From Mars Show Electrostatic Charging of the Mars Pathfinder Sojourner Rover

    NASA Technical Reports Server (NTRS)

    Kolecki, Joseph C.; Siebert, Mark W.

    1998-01-01

    Indirect evidence (dust accumulation) has been obtained indicating that the Mars Pathfinder rover, Sojourner, experienced electrostatic charging on Mars. Lander camera images of the Sojourner rover provide distinctive evidence of dust accumulation on rover wheels during traverses, turns, and crabbing maneuvers. The sol 22 (22nd Martian "day" after Pathfinder landed) end-of-day image clearly shows fine red dust concentrated around the wheel edges with additional accumulation in the wheel hubs. A sol 41 image of the rover near the rock "Wedge" (see the next image) shows a more uniform coating of dust on the wheel drive surfaces with accumulation in the hubs similar to that in the previous image. In the sol 41 image, note particularly the loss of black-white contrast on the Wheel Abrasion Experiment strips (center wheel). This loss of contrast was also seen when dust accumulated on test wheels in the laboratory. We believe that this accumulation occurred because the Martian surface dust consists of clay-sized particles, similar to those detected by Viking, which have become electrically charged. By adhering to the wheels, the charged dust carries a net nonzero charge to the rover, raising its electrical potential relative to its surroundings. Similar charging behavior was routinely observed in an experimental facility at the NASA Lewis Research Center, where a Sojourner wheel was driven in a simulated Martian surface environment. There, as the wheel moved and accumulated dust (see the following image), electrical potentials in excess of 100 V (relative to the chamber ground) were detected by a capacitively coupled electrostatic probe located 4 mm from the wheel surface. The measured wheel capacitance was approximately 80 picofarads (pF), and the calculated charge, 8 x 10(exp -9) coulombs (C). Voltage differences of 100 V and greater are believed sufficient to produce Paschen electrical discharge in the Martian atmosphere. With an accumulated net charge of 8 x 10(exp

  9. Test Results From The Idaho National Laboratory Of The NASA Bi-Supported Cell Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C Stoots; J O'Brien; T Cable

    The Idaho National Laboratory has been researching the application of solid-oxide fuel cell technology for large-scale hydrogen production. As a result, the Idaho National Laboratory has been testing various cell designs to characterize electrolytic performance. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This paper presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising designmore » for both high power-to-weight fuel cell and electrolyzer applications.« less

  10. T3 (Triiodothyronine) Test

    MedlinePlus

    ... Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy hCG Tumor Marker HDL Cholesterol ... Semen Analysis Serotonin Serum Free Light Chains Sex Hormone Binding Globulin ... Transferrin Receptor Stool Culture Stool Elastase Strep ...

  11. 12 CFR 252.156 - Reports of stress test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 4 2014-01-01 2014-01-01 false Reports of stress test results. 252.156 Section... SYSTEM (CONTINUED) ENHANCED PRUDENTIAL STANDARDS (REGULATION YY) Company-Run Stress Test Requirements for....156 Reports of stress test results. (a) Reports to the Board of stress test results—(1) Savings and...

  12. Results of Tests Performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel

    NASA Technical Reports Server (NTRS)

    Barna, P. S.

    1995-01-01

    The test results briefly described in this report were obtained on the three-dimensional 1:48 scale tunnel modeled on the design proposed by Messrs. D.S.M.A. Corporation. More particularly, while the test chamber dimensions were indeed scaled down in the ration of 1:48, including the contraction and the collector as well, the duct system itself leading to and from the chamber was adapted to suit laboratory conditions and space limitations. Earlier tests with the two-dimensional model showed that blowing mode was preferred as against the suction mode, hence all tests were performed with blowing only. At the exit of the contraction the maximum airspeed attained with the 1 HP blower unit was about 200 ft/sec. This airspeed may be increased in future if desired. The test results show that pressure recovery in the diffuser was about 34 percent due to the large blockage at its entrance. Velocity traverses taken across the diffuser entrance explain the reason for this blockage. Recirculation, studied with both, hot-wire anemometry and flow-visualization techniques, was largely affected by the design of the test chamber itself and the amount of vent-air admitted to the chamber. Vent-air helped to decrease the level of turbulence.

  13. Effects of different centrifugation conditions on clinical chemistry and Immunology test results.

    PubMed

    Minder, Elisabeth I; Schibli, Adrian; Mahrer, Dagmar; Nesic, Predrag; Plüer, Kathrin

    2011-05-10

    The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One) were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p < 0.05, which was less than the expected 5%. This suggests that the outliers are the result of random variation and the large number of statistical tests performed. Further, we found that our data are sufficient not to miss a biased test (beta error) with a probability of 0.10 to 0.05 in most parameters. A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study.

  14. Testing of stiffening ribs formed by incremental forming in thin-walled aircraft structures made of 2024-T3 ALCLAD aluminium alloy

    NASA Astrophysics Data System (ADS)

    Kubit, Andrzej; Wydrzynski, Dawid; Bucior, Magdalena; Krasowski, Bogdan

    2018-05-01

    This paper presents the results of experimental tests on the fabrication of longitudinal stiffening ribs in 2024-T3 ALCLAD aluminum alloy sheet, which is widely used in the aircraft structures. The problem presented in this paper concerns the concept of rib-stiffening of the structure of aircraft skin. The ribs are intended to stiffen integral thin-walled structure. Different shapes and different parameters of the forming process were studied. The rib-stiffened samples of various depths of the ribs were tested experimentally in the buckling test.

  15. Results and analysis of the switchyard impact tests

    DOT National Transportation Integrated Search

    1980-01-01

    This report presents the results and analysis of series 3 through 7 and series 10 of the FRA/RPI/AAR Switchyard Impact Tests. The test results and analysis are used to evaluate the head shield and the shelf-E coupler as protective devices for hazardo...

  16. Support Seeking or Familial Obligation: An Investigation of Motives for Disclosing Genetic Test Results.

    PubMed

    Greenberg, Marisa; Smith, Rachel A

    2016-01-01

    Genetic test results reveal not only personal information about a person's likelihood of certain medical conditions but also information about the person's genetic relatives. Given the familial nature of genetic information, one's obligation to protect family members may be a motive for disclosing genetic test results, but this claim has not been methodically tested. Existing models of disclosure decision making presume self-interested motives, such as seeking social support, instead of other-interested motives, like familial obligation. This study investigated young adults' (N = 173) motives to share a genetic-based health condition, alpha-1 antitrypsin deficiency, after reading a hypothetical vignette. Results show that social support and familial obligation were both reported as motives for disclosure. In fact, some participants reported familial obligation as their primary motivator for disclosure. Finally, stronger familial obligation predicted increased likelihood of disclosing hypothetical genetic test results. Implications of these results were discussed in reference to theories of disclosure decision-making models and the practice of genetic disclosures.

  17. Preliminary test results from the CELSS Test Facility Engineering Development Unit

    NASA Technical Reports Server (NTRS)

    Kliss, Mark H.; Macelroy, R. D.; Blackwell, C. C.; Borchers, B. A.; Drews, M. E.; Longabaugh, J. R.; Yendler, B. S.; Zografos, A. I.

    1994-01-01

    As part of the NASA Controlled Ecological Life Support System (CELSS) Program, a CELSS Test Facility (CTF) is being planned for installation on the Space Station. The CTF will be used to provide data on the productivity and efficiency of a variety of CELSS higher plant crops grown in the microgravity environment of the Space Station. Tight environmental control will be maintained while data on gas exchange rates and biomass accumulation rates are collected. In order to obtain an early realistic determination of the subsystem and system requirements necessary to provide the environmental conditions specified for CTF crop productivity experiments, an Engineering Development Unit (EDU) has been designed, constructed and is in the process of subsystem and system testing at NASA Ames Research Center. The EDU is a ground test-bed which will be used to characterize the integrated performance of major subsystem technologies, to evaluate hardware candidates and control strategies required for the CTF, and to further define the ability to meet CTF requirements within present Space Station constraints. This paper reviews the functional requirements for the EDU, and focuses on the performance evaluation and test results of the various subsystems. Preliminary integrated performance results and control system operation are addressed, and plans for future science and technology testing are discussed.

  18. User testing of an adaptation of fishbone diagrams to depict results of systematic reviews.

    PubMed

    Gartlehner, Gerald; Schultes, Marie-Therese; Titscher, Viktoria; Morgan, Laura C; Bobashev, Georgiy V; Williams, Peyton; West, Suzanne L

    2017-12-12

    Summary of findings tables in systematic reviews are highly informative but require epidemiological training to be interpreted correctly. The usage of fishbone diagrams as graphical displays could offer researchers an effective approach to simplify content for readers with limited epidemiological training. In this paper we demonstrate how fishbone diagrams can be applied to systematic reviews and present the results of an initial user testing. Findings from two systematic reviews were graphically depicted in the form of the fishbone diagram. To test the utility of fishbone diagrams compared with summary of findings tables, we developed and pilot-tested an online survey using Qualtrics. Respondents were randomized to the fishbone diagram or a summary of findings table presenting the same body of evidence. They answered questions in both open-ended and closed-answer formats; all responses were anonymous. Measures of interest focused on first and second impressions, the ability to find and interpret critical information, as well as user experience with both displays. We asked respondents about the perceived utility of fishbone diagrams compared to summary of findings tables. We analyzed quantitative data by conducting t-tests and comparing descriptive statistics. Based on real world systematic reviews, we provide two different fishbone diagrams to show how they might be used to display complex information in a clear and succinct manner. User testing on 77 students with basic epidemiological training revealed that participants preferred summary of findings tables over fishbone diagrams. Significantly more participants liked the summary of findings table than the fishbone diagram (71.8% vs. 44.8%; p < .01); significantly more participants found the fishbone diagram confusing (63.2% vs. 35.9%, p < .05) or indicated that it was difficult to find information (65.8% vs. 45%; p < .01). However, more than half of the participants in both groups were unable to find

  19. Upper Stage Flight Experiment 10K Engine Design and Test Results

    NASA Technical Reports Server (NTRS)

    Ross, R.; Morgan, D.; Crockett, D.; Martinez, L.; Anderson, W.; McNeal, C.

    2000-01-01

    A 10,000 lbf thrust chamber was developed for the Upper Stage Flight Experiment (USFE). This thrust chamber uses hydrogen peroxide/JP-8 oxidizer/fuel combination. The thrust chamber comprises an oxidizer dome and manifold, catalyst bed assembly, fuel injector, and chamber/nozzle assembly. Testing of the engine was done at NASA's Stennis Space Center (SSC) to verify its performance and life for future upper stage or Reusable Launch Vehicle applications. Various combinations of silver screen catalyst beds, fuel injectors, and combustion chambers were tested. Results of the tests showed high C* efficiencies (97% - 100%) and vacuum specific impulses of 275 - 298 seconds. With fuel film cooling, heating rates were low enough that the silica/quartz phenolic throat experienced minimal erosion. Mission derived requirements were met, along with a perfect safety record.

  20. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    PubMed Central

    2010-01-01

    Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003