Sample records for tachycardia heart rate

  1. Tachycardia | Fast Heart Rate

    MedlinePlus

    ... sinoatrial (SA) node --- the heart's natural pacemaker. A series of early beats in the atria speeds up the heart rate. The rapid heartbeat does not allow enough time for the heart to fill before it contracts ...

  2. Autonomic control of heart rate during orthostasis and the importance of orthostatic-tachycardia in the snake Python molurus.

    PubMed

    Armelin, Vinicius Araújo; da Silva Braga, Victor Hugo; Abe, Augusto Shinya; Rantin, Francisco Tadeu; Florindo, Luiz Henrique

    2014-10-01

    Orthostasis dramatically influences the hemodynamics of terrestrial vertebrates, especially large and elongated animals such as snakes. When these animals assume a vertical orientation, gravity tends to reduce venous return, cardiac filling, cardiac output and blood pressure to the anterior regions of the body. The hypotension triggers physiological responses, which generally include vasomotor adjustments and tachycardia to normalize blood pressure. While some studies have focused on understanding the regulation of these vasomotor adjustments in ectothermic vertebrates, little is known about regulation and the importance of heart rate in these animals during orthostasis. We acquired heart rate and carotid pulse pressure (P PC) in pythons in their horizontal position, and during 30 and 60° inclinations while the animals were either untreated (control) or upon muscarinic cholinoceptor blockade and a double autonomic blockade. Double autonomic blockade completely eradicated the orthostatic-tachycardia, and without this adjustment, the P PC reduction caused by the tilts became higher than that which was observed in untreated animals. On the other hand, post-inclinatory vasomotor adjustments appeared to be of negligible importance in counterbalancing the hemodynamic effects of gravity. Finally, calculations of cardiac autonomic tones at each position revealed that the orthostatic-tachycardia is almost completely elicited by a withdrawal of vagal drive.

  3. Ventricular arrhythmias and changes in heart rate preceding ventricular tachycardia in patients with an implantable cardioverter defibrillator.

    PubMed

    Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon

    2008-07-01

    The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.

  4. [Ventricular tachycardia in a patient with rate-responsive cardiac pacemaker].

    PubMed

    Himbert, C; Lascault, G; Tonet, J; Coutte, R; Busquet, P; Frank, R; Grosgogeat, Y

    1992-11-01

    The authors report a case of syncopal ventricular tachycardia in a patient with a respiratory-dependent rate responsive pacemaker, followed-up for valvular heart disease with severe left ventricular dysfunction and sustained atrial and ventricular arrhythmias. The introduction of low dose betablocker therapy with reinforcement of the treatment of cardiac failure controlled the ventricular arrhythmia, after suppression of the data responsive function had been shown to be ineffective. The authors discuss the role of the rate responsive function in the triggering of the ventricular tachycardias.

  5. Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease.

    PubMed

    Klein, L S; Shih, H T; Hackett, F K; Zipes, D P; Miles, W M

    1992-05-01

    Radiofrequency energy has been used safely and successfully to eliminate accessory pathways in patients with the Wolff-Parkinson-White syndrome and the substrate for atrioventricular nodal reentrant tachycardia. However, this form of ablation has had only limited success in eliminating ventricular tachycardia in patients with structural heart disease. In contrast, direct-current catheter ablation has been used successfully to eliminate ventricular tachycardia in patients with and without structural heart disease. The purpose of this study was to test whether radiofrequency energy can safely and effectively ablate ventricular tachycardia in patients without structural heart disease. Sixteen patients (nine women and seven men; mean age, 38 years; range, 18-55 years) without structural heart disease who had ventricular tachycardia underwent radiofrequency catheter ablation to eliminate the ventricular tachycardia. Two patients presented with syncope, nine with presyncope, and five with palpitations only. Mean duration of symptoms was 6.7 years (range, 0.5-20 years). Radiofrequency catheter ablation successfully eliminated ventricular tachycardia in 15 of 16 patients (94%). Sites of ventricular tachycardia origin included the high right ventricular outflow tract (12 patients), the right ventricular septum near the tricuspid valve (three patients), and the left ventricular septum (one patient). The only ablation failure was in a patient whose ventricular tachycardia arose from a region near the His bundle. An accurate pace map, early local endocardial activation, and firm catheter contact with endocardium were associated with successful ablation. Radiofrequency ablation did not cause arrhythmias, produced minimal cardiac enzyme rise, and resulted in no detectable change in cardiac function by Doppler echocardiography. Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease is effective and safe and may be considered as

  6. Paroxysmal supraventricular tachycardia (PSVT)

    MedlinePlus

    PSVT; Supraventricular tachycardia; Abnormal heart rhythm - PSVT; Arrhythmia - PSVT; Rapid heart rate - PSVT; Fast heart rate - PSVT ... Normally, the chambers of the heart (atria and ventricles) contract in ... are caused by an electrical signal that begins in an area ...

  7. Contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

    PubMed

    Krause, Ulrich; Backhoff, David; Klehs, Sophia; Schneider, Heike E; Paul, Thomas

    2016-08-01

    Monitoring of catheter contact force during catheter ablation of atrial fibrillation has been shown to increase efficacy and safety. However, almost no data exists on the use of this technology in catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease. The aim of the present study was to evaluate the impact of contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in those patients. Catheter ablation of intraatrial reentrant tachycardia using monitoring of catheter contact force was performed in 28 patients with congenital heart disease (CHD). Thirty-two patients matched according to gender, age, and body weight with congenital heart disease undergoing catheter ablation without contact force monitoring served as control group. Parameters reflecting acute procedural success, long-term efficacy, and safety were compared. Acute procedural success was statistically not different in both groups (contact force 93 % vs. control 84 %, p = 0.3). Likewise the recurrence rate 1 year after ablation as shown by Kaplan-Meier analysis did not differ (contact force 28 % vs. control 37 %, p = 0.63). Major complications were restricted to groin vessel injuries and occurred in 3 out of 60 patients (contact force n = 1; control n = 2). Complications related to excessive catheter contact force were not observed. The present study did not show superiority of catheter contact force monitoring during ablation of intraatrial reentrant tachycardia in patients with CHD in terms of efficacy and safety. Higher contact force compared to pulmonary vein isolation might therefore be required to increase the efficacy of catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

  8. Ischemic Ventricular Tachycardia Presenting as a Narrow Complex Tachycardia

    PubMed Central

    Page, Stephen P; Watts, Troy; Yeo, Wee Tiong; Mehul, Dhinoja

    2014-01-01

    This report describes a patient presenting with a narrow complex tachycardia in the context of prior myocardial infarction and impaired ventricular function. Electrophysiological studies confirmed ventricular tachycardia and activation and entrainment mapping demonstrated a critical isthmus within an area of scar involving the His-Purkinje system accounting for the narrow QRS morphology. This very rare case shares some similarities with upper septal ventricular tachycardia seen in patients with structurally normal hearts, but to our knowledge has not been seen previously in patients with ischemic heart disease. PMID:25057222

  9. Humoral regulation of heart rate during digestion in pythons (Python molurus and Python regius).

    PubMed

    Enok, Sanne; Simonsen, Lasse Stærdal; Pedersen, Signe Vesterskov; Wang, Tobias; Skovgaard, Nini

    2012-05-15

    Pythons exhibit a doubling of heart rate when metabolism increases several times during digestion. Pythons, therefore, represent a promising model organism to study autonomic cardiovascular regulation during the postprandial state, and previous studies show that the postprandial tachycardia is governed by a release of vagal tone as well as a pronounced stimulation from nonadrenergic, noncholinergic (NANC) factors. Here we show that infusion of plasma from digesting donor pythons elicit a marked tachycardia in fasting snakes, demonstrating that the NANC factor resides in the blood. Injections of the gastrin and cholecystokinin receptor antagonist proglumide had no effect on double-blocked heart rate or blood pressure. Histamine has been recognized as a NANC factor in the early postprandial period in pythons, but the mechanism of its release has not been identified. Mast cells represent the largest repository of histamine in vertebrates, and it has been speculated that mast cells release histamine during digestion. Treatment with the mast cell stabilizer cromolyn significantly reduced postprandial heart rate in pythons compared with an untreated group but did not affect double-blocked heart rate. While this study indicates that histamine induces postprandial tachycardia in pythons, its release during digestion is not stimulated by gastrin or cholecystokinin nor is its release from mast cells a stimulant of postprandial tachycardia.

  10. Heart rate differentiates urgency and emergency in hypertensive crisis.

    PubMed

    Al Bannay, Rashed; Böhm, Michael; Husain, Aysha

    2013-08-01

    To study the clinical significance of presenting blood pressure parameters and heart rate in patients with hypertensive crisis. In patients admitted with hypertensive crisis between January 2011 and May 2011, demography, mode of presentation, co-morbidities, blood pressure readings, and heart rate at presentation were documented. Further clustering of hypertensive crisis into emergency or urgency was based on the presence or absence of target organ involvement. The relationship between blood pressure parameters, heart rate, and other variables was analyzed. 189 patients in sinus rhythm were enrolled in this pilot study. The rate of hypertensive urgency was 56 %, whereas the rate of hypertensive emergency was 44 %, respectively. Subjects with hypertensive emergency had a higher mean heart rate (93 ± 22.7 bpm) than those with urgency (81 ± 11.5 bpm) (P = 0.015). Women had higher heart rates (92 ± 18.5 bpm) than men (86 ± 17.6 bpm) (P = 0.014). Heart rates below 100 bpm had a specificity of 94 %, classifying patients as hypertensive urgency. Tachycardia had a powerful statistical association with hypertensive left ventricular failure (P < 0.0001). Other hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, pulse pressure, and mean blood pressure relates neither to urgency nor to emergency. Diabetic patients with HBA1c levels of more than 53 mmol/mol had a heart rate of more than 100 bpm (P = 0.015) during hypertensive crisis. Normal heart rate is characteristic of hypertensive urgency. Tachycardia in this setting is an ominous sign and denotes hypertensive complications in particular left ventricular failure. Among diabetics, elevated heart rate is associated with poor glycemic control.

  11. Animal model of neuropathic tachycardia syndrome

    NASA Technical Reports Server (NTRS)

    Carson, R. P.; Appalsamy, M.; Diedrich, A.; Davis, T. L.; Robertson, D.

    2001-01-01

    Clinically relevant autonomic dysfunction can result from either complete or partial loss of sympathetic outflow to effector organs. Reported animal models of autonomic neuropathy have aimed to achieve complete lesions of sympathetic nerves, but incomplete lesions might be more relevant to certain clinical entities. We hypothesized that loss of sympathetic innervation would result in a predicted decrease in arterial pressure and a compensatory increase in heart rate. Increased heart rate due to loss of sympathetic innervation is seemingly paradoxical, but it provides a mechanistic explanation for clinical autonomic syndromes such as neuropathic postural tachycardia syndrome. Partially dysautonomic animals were generated by selectively lesioning postganglionic sympathetic neurons with 150 mg/kg 6-hydroxydopamine hydrobromide in male Sprague-Dawley rats. Blood pressure and heart rate were monitored using radiotelemetry. Systolic blood pressure decreased within hours postlesion (Delta>20 mm Hg). Within 4 days postlesion, heart rate rose and remained elevated above control levels. The severity of the lesion was determined functionally and pharmacologically by spectral analysis and responsiveness to tyramine. Low-frequency spectral power of systolic blood pressure was reduced postlesion and correlated with the diminished tyramine responsiveness (r=0.9572, P=0.0053). The tachycardia was abolished by treatment with the beta-antagonist propranolol, demonstrating that it was mediated by catecholamines acting on cardiac beta-receptors. Partial lesions of the autonomic nervous system have been hypothesized to underlie many disorders, including neuropathic postural tachycardia syndrome. This animal model may help us better understand the pathophysiology of autonomic dysfunction and lead to development of therapeutic interventions.

  12. The initial (earliest) report of polymorphous ventricular tachycardia.

    PubMed

    Jani, Sonal; Schweitzer, Paul

    2006-07-01

    In these short historical notes, we describe the early history of polymorphic ventricular tachycardia. Polymorphous ventricular tachycardia was probably first noted in 1918 by Wilson and Robinson. In a publication describing complete heart block and ventriculophasic arrhythmia, they noted a tachyarrhythmia characterized by multiple extrasystoles of different types at a rapid rate. Also, we briefly discuss the earliest recognized torsades de pointes by Dessertenes in 1966 and the first description of catecholaminergic polymorphic ventricular tachycardia, by Reid in 1977.

  13. Radiofrequency catheter ablation in patients with symptomatic atrial flutter/tachycardia after orthotopic heart transplantation.

    PubMed

    Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H

    2006-12-20

    Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of

  14. The Impact of Time to Rate Control of Junctional Ectopic Tachycardia After Congenital Heart Surgery.

    PubMed

    Lim, Joel Kian Boon; Mok, Yee Hui; Loh, Yee Jim; Tan, Teng Hong; Lee, Jan Hau

    2017-11-01

    Junctional ectopic tachycardia (JET) after congenital heart disease (CHD) surgery is often self-limiting but is associated with increased risk of morbidity and mortality. Contributing factors and impact of time to achieve rate control of JET are poorly described. From January 2010 to June 2015, a retrospective, single-center cohort study was performed of children who developed JET after CHD surgery . We classified the cohort into two groups: patients who achieved rate control of JET in ≤24 hours and in >24 hours. We examined factors associated with time to rate control and compared clinical outcomes (mortality, duration of mechanical ventilation, length of intensive care unit [ICU], and hospital stay) between the two groups. Our cohort included 27 children, with a median age of 3 (interquartile range: 0.7-38] months. The most common CHD lesions were ventricular septal defect (n = 10, 37%), tetralogy of Fallot (n = 7, 25.9%), and transposition of the great arteries (n = 4, 14.8%). In all, 15 (55.6%) and 12 (44.4%) patients achieved rate control of JET in ≤24 hours and >24 hours, respectively. There was a difference in median mechanical ventilation time (97 [21-145) vs 311 [100-676] hours; P = .013) and ICU stay (5.0 [2.0-8.0] vs 15.5 [5.5-32.8] days, P = .023) between the patients who achieved faster rate control than those who didn't. There was no difference in length of hospital stay and mortality between the groups. Our study demonstrated that time to achieve rate control of JET was associated with increased duration of mechanical ventilation and ICU stay.

  15. FPGA Implementation of Heart Rate Monitoring System.

    PubMed

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  16. Dynamic analysis of heart rate may predict subsequent ventricular tachycardia after myocardial infarction

    NASA Technical Reports Server (NTRS)

    Makikallio, T. H.; Seppanen, T.; Airaksinen, K. E.; Koistinen, J.; Tulppo, M. P.; Peng, C. K.; Goldberger, A. L.; Huikuri, H. V.

    1997-01-01

    Dynamics analysis of RR interval behavior and traditional measures of heart rate variability were compared between postinfarction patients with and without vulnerability to ventricular tachyarrhythmias in a case-control study. Short-term fractal correlation of heart rate dynamics was better than traditional measures of heart rate variability in differentiating patients with and without life-threatening arrhythmias.

  17. Alterations in myocardial free fatty acid clearance precede mechanical abnormalities in canine tachycardia-induced heart failure.

    PubMed

    Freeman, G L; Colston, J T; Miller, D D

    1994-01-01

    The purpose of this study was to evaluate whether abnormalities of free fatty acid metabolism are present before the onset of overt mechanical dysfunction in dogs with tachycardia-induced heart failure. We studied six dogs chronically instrumented to allow assessment of left ventricular function in the pressure-volume plane. Free fatty acid clearance was assessed according to the washout rate of a free fatty acid analog, iodophenylpentadecanoic acid ([123I]PPA or IPPA). IPPA clearance was measured within 1 hour of the hemodynamic assessment. The animals were studied under baseline conditions and 11.7 +/- 3.6 days after ventricular pacing at a rate of 240 beats/min. Hemodynamic studies after pacing showed a nonsignificant increase in left ventricular end-diastolic pressure (11.7 +/- 4.7 to 17.4 +/- 6.5 mm Hg) and a nonsignificant decrease in the maximum derivative of pressure with respect to time (1836 +/- 164 vs 1688 +/- 422 mm Hg/sec). There was also no change in the time constant of left ventricular relaxation, which was 34.8 +/- 7.67 msec before and 35.3 +/- 7.3 msec after pacing. However, a significant prolongation in the clearance half-time of [123I]PPA, from 86.1 +/- 23.9 to 146.5 +/- 22.6 minutes (p < 0.01) was found. Thus abnormal lipid clearance appears before the onset of significant mechanical dysfunction in tachycardia-induced heart failure. This suggests that abnormal substrate metabolism may play an important role in the pathogenesis of this condition.

  18. Use of an allostatic neurotechnology by adolescents with postural orthostatic tachycardia syndrome (POTS) is associated with improvements in heart rate variability and changes in temporal lobe electrical activity.

    PubMed

    Fortunato, John E; Tegeler, Catherine L; Gerdes, Lee; Lee, Sung W; Pajewski, Nicholas M; Franco, Meghan E; Cook, Jared F; Shaltout, Hossam A; Tegeler, Charles H

    2016-03-01

    Autonomic dysregulation and heterogeneous symptoms characterize postural orthostatic tachycardia syndrome (POTS). This study evaluated the effect of high-resolution, relational, resonance-based, electroencephalic mirroring (HIRREM(®)), a noninvasive, allostatic neurotechnology for relaxation and auto-calibration of neural oscillations, on heart rate variability, brain asymmetry, and autonomic symptoms, in adolescents with POTS. Seven subjects with POTS (three males, ages 15-18) underwent a median of 14 (10-16) HIRREM sessions over 13 (8-17) days. Autonomic function was assessed from 10-min continuous heart rate and blood pressure recordings, pre- and post-HIRREM. One-minute epochs of temporal high-frequency (23-36 Hz) brain electrical activity data (T3 and T4, eyes closed) were analyzed from baseline HIRREM assessment and subsequent sessions. Subjects rated autonomic symptoms before and after HIRREM. Four of seven were on fludrocortisone, which was stopped before or during their sessions. Heart rate variability in the time domain (standard deviation of the beat-to-beat interval) increased post-HIRREM (mean increase 51%, range 10-143, p = 0.03), as did baroreflex sensitivity (mean increase in high-frequency alpha 65%, range -6 to 180, p = 0.05). Baseline temporal electrical asymmetry negatively correlated with change in asymmetry from assessment to the final HIRREM session (p = 0.01). Summed high-frequency amplitudes at left and right temporal lobes decreased a median of 3.8 μV (p = 0.02). There was a trend for improvements in self-reported symptoms related to the autonomic nervous system. Use of HIRREM was associated with reduced sympathetic bias in autonomic cardiovascular regulation, greater symmetry and reduced amplitudes in temporal lobe high-frequency electrical activity, and a trend for reduced autonomic symptoms. Data suggest the potential for allostatic neurotechnology to facilitate increased flexibility in autonomic cardiovascular regulation, possibly

  19. [Orthostatic postural tachycardia: study of 8 patients].

    PubMed

    Santiago Pérez, S; Ferrer Gila, T

    1998-02-07

    The occurrence of syncopal episodes is a very frequent event. In the absence of a structural systemic or cardiac disease, syncope is resulting of an anomalous cardiovascular response neurally mediated by the autonomic nervous system. It is the final common manifestation of different abnormal mechanisms and is frequently precipitated by orthostatism. Orthostatic intolerance syndrome refers to the development of symptoms during the upright posture that disappear in supine position. Tachycardia may be one of the clinical features of the syndrome. During orthostatic stress a hyperadrenergic response, with maintained increment of heart rate and associated symptoms, is developed. Changes in blood pressure may be diverse and in some cases hypotension and syncope occurs. Eight patients with symptoms of orthostatic intolerance who underwent autonomic evaluation and were diagnosed from postural tachycardia are presented. In all the cases an abnormal increment of heart rate during tilting was found and it was associated to hyperadrenergic symptoms. Evidence of restricted sympathetic impairment was observed in six cases with distal reduction of sudomotor function and abnormal adrenergic response during Valsalva manoeuvre. Symptoms disappeared or mostly subsided with pharmacological (amitriptyline in one case, phenobarbital in another one and non-cardioselective beta-blockers in six patients) and non-pharmacological treatment. In further examinations heart rate and blood pressure were normal.

  20. Persistent tachycardia in clozapine treated patients: A 24-hour ambulatory electrocardiogram study.

    PubMed

    Nilsson, Björn M; Lindström, Leif; Mohsen, Issam; Holmlöv, Karolina; Bodén, Robert

    2018-03-27

    Tachycardia is associated with cardiovascular mortality. Tachycardia is also a known clozapine adverse effect. However, whether clozapine-associated tachycardia is persistent is not known. Thirty clozapine-treated patients with clinical tachycardia were investigated with 24-hour ambulatory electrocardiography (ECG). Baseline peripheral heart rate (HR) was 106.7±7.8. The ambulatory ECG 24-hour-HR was 98.7±9.7. Baseline HR and 24-hour-HR correlated strongly (r=0.74, p=0.000003). Daytime HR was 106.4±9.9 and nighttime HR 89.2±12.0. Low dose bisoprolol reduced HR significantly. The high 24-hour-HR indicates a persistent tachycardia. Tachycardia should not discourage from clozapine use but the findings indicate a need of guidelines for detection and treatment of clozapine-associated tachycardia. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Effects of nitric oxide synthase inhibition on sympathetically-mediated tachycardia

    NASA Technical Reports Server (NTRS)

    Whalen, E. J.; Johnson, A. K.; Lewis, S. J.

    1999-01-01

    The aim of the present study was to determine whether inhibition of nitric oxide (NO) synthesis directly alters the tachycardia produced by sympathetically-derived norepinephrine. The NO synthase inhibitor, N(G)-nitro-L-arginine methyl ester (L-NAME; 50 micromol/kg, i.v.), produced a marked rise in mean arterial blood pressure. This pressor response was associated with a fall in heart rate which involved the withdrawal of cardiac sympathetic nerve activity. The NO-donor, sodium nitroprusside (5 microg/kg, i.v.), produced a pronounced fall in mean arterial blood pressure but only a minor increase in heart rate. The beta-adrenoceptor agonist, isoproterenol (0.5 micromol/kg, i.v.), and the membrane-permeable cAMP analogue, 8-(4-chlorophenylthiol)-cAMP (10 micromol/kg, i.v.), produced falls in mean arterial blood pressure and pronounced increases in heart rate. The indirectly acting sympathomimetic agent, tyramine (0.5 mg/kg, i.v.), produced a pressor response and a tachycardia. The effects of sodium nitroprusside, tyramine, isoproterenol and 8-(4-chlorophenylthiol)-cAMP on mean arterial blood pressure were not markedly affected by L-NAME. However, the tachycardia produced by these agents was considerably exaggerated in the presence of this NO synthesis inhibitor. These findings suggest that L-NAME potentiates the tachycardia produced by sympathetically-derived norepinephrine. The increased responsiveness to norepinephrine may involve (i) a rapid up-regulation of cardiac beta1-adrenoceptors and cAMP signaling in cardiac pacemaker cells due to the loss of the inhibitory influence of cardiac NO, and (ii) the up-regulation of beta1-adrenoceptor-mediated signal transduction processes in response to the L-NAME-induced withdrawal of cardiac sympathetic nerve activity.

  2. [Time-dependent heart rate variability in the head-up tilt test in children with postural orthostatic tachycardia syndrome].

    PubMed

    Ran, Jing; Wang, Cheng; Zou, Run-Mei; Wu, Li-Jia; Lin, Ping; Li, Fang; Xu, Yi

    2015-10-01

    To study the time-dependent heart rate (HR) variability in the head-up tilt test (HUTT) in children with postural orthostatic tachycardia syndrome (POTS) and to explore the HR diagnostic criteria for POTS in children. A retrospective analysis was performed on the clinical data of 105 children diagnosed with POTS with HR≥120 beats per minute (bpm) within the first 10 minutes of HUTT between January 2007 and December 2014. Their HR variability within the first 10 minutes of HUTT was analyzed. The HR of children with POTS increased gradually from the supine position to a 60° head-up tilt position, and the increase in HR was 24±12 bpm at the beginning of HUTT, 30±14 bpm at 3 minutes of HUTT, 32±13 bpm at 5 minutes of HUTT, and 38±12 bpm at 10 minutes of HUTT. The average maximal HR increase within the first 10 minutes of HUTT was 43±10 bpm. In children with POTS, the HR variability gradually increases with time, and therefore, it is suggested that HR increase ≥40 bpm is more suitable for diagnosis of POTS in children.

  3. Postural tachycardia syndrome and inappropriate sinus tachycardia: role of autonomic modulation and sinus node automaticity.

    PubMed

    Nwazue, Victor C; Paranjape, Sachin Y; Black, Bonnie K; Biaggioni, Italo; Diedrich, André; Dupont, William D; Robertson, David; Raj, Satish R

    2014-04-10

    Inappropriate sinus tachycardia (IST) and postural tachycardia syndrome (POTS) are 2 disorders characterized by sinus tachycardia. It is debated whether the pathophysiology of IST and POTS results from abnormal autonomic regulation or abnormal sinus node function. We hypothesized that intrinsic heart rate (IHR) after autonomic blockade would be increased in patients with IST but not POTS. We enrolled 48 POTS patients, 8 IST patients, and 17 healthy control (HC) subjects. Intravenous propranolol and atropine were given to block the sympathetic and parasympathetic limbs of the autonomic nervous system in order to determine the IHR. Patients with IST have a higher sympathetic contribution to heart rate when compared with POTS patients (31±13 bpm versus 12±7 bpm, P<0.001) and HC (8±4 bpm; P<0.001) and a trend to less parasympathetic contribution than POTS and HC (IST: 31±11 bpm versus POTS: 46±11 bpm versus HC: 48±11 bpm, ANOVA P=0.108). IHR was not significantly different between IST and either POTS or HC (IST: 111±11 bpm versus POTS: 108±11 bpm versus HC: 106±12 bpm, ANOVA P=0.237). IST patients have more sympathetic tone when compared with either POTS or HC, but IST patients do not have abnormal sinus node automaticity. These data suggest that the treatment of IST and POTS should focus on sympatholysis, reserving sinus node modification for patients with continued debilitating symptoms after beta-blockade and possibly ivabradine. http://clinicaltrials.gov/. Unique identifier: NCT00262470.

  4. Tachycardia During Resistance Exercise: A Case Study.

    ERIC Educational Resources Information Center

    Fry, Andrew C.; Parks, Michael J.

    2001-01-01

    This case study examined a weight-trained (WT) male who had an unusually high heart rate response to heavy resistance exercise and self-administered anabolic androgenic steroids as an ergogenic aid to training. The subject was compared to 18 other WT people. His tachycardia response occurred only in the presence of a pressure load and not with a…

  5. Challenges in Treatment of Inappropriate Sinus Tachycardia.

    PubMed

    Ruzieh, Mohammed; Moustafa, Abdelmoniem; Sabbagh, Ebrahim; Karim, Mohammad M; Karim, Saima

    2018-03-14

    Inappropriate Sinus Tachycardia (IST) is a clinical syndrome characterized by a sinus heart rate inexplicably higher than one hundred beats per minute at rest that is associated with symptoms like palpitations, dyspnea or dizziness in the absence of primary causes of tachycardia. The diagnosis requires exclusion of other causes of tachycardia including medications/substances (such as anti-cholinergic, beta-blocker withdrawal, caffeine, and alcohol) or medical conditions (such as panic attacks, pulmonary embolism, fever, hyperthyroidism, hypovolemia, anemia, and pain). Work up should include an EKG to differentiate other causes of tachycardia, 24 hour- Holter monitor if indicated, serum thyroid levels, hemoglobin levels and toxicology screen. Electrophysiological studies are not routinely recommended, but should be considered in certain patients in whom concurrent supraventricular tachycardia is suspected. The underlying pathology in IST is yet to be completely understood. However, it is thought that the causes of IST can be broadly classified into two groups; either as an intrinsic increase in sinus node automaticity or an extrinsic cause. Among extrinsic causes, there is evolving evidence that IgG anti-β receptor antibodies are found in IST causing tachycardia. Managing patients with IST includes lifestyle modification, non-pharmacological and pharmacological interventions. Ivabradine has recently emerged as an effective treatment of IST and was shown to be superior to beta-blockers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. [AV-reentrant tachycardia and Wolff-Parkinson-White syndrome : Diagnosis and treatment].

    PubMed

    Voss, Frederik; Eckardt, Lars; Busch, Sonia; Estner, Heidi L; Steven, Daniel; Sommer, Philipp; von Bary, Christian; Neuberger, Hans-Ruprecht

    2016-12-01

    The AV-reentrant tachycardia (AVRT) is a supraventricular tachycardia with an incidence of 1-3/1000. The pathophysiological basis is an accessory atrioventricular pathway (AP). Patients with AVRT typically present with palpitations, an on-off characteristic, anxiety, dyspnea, and polyuria. This type of tachycardia may often be terminated by vagal maneuvers. Although the clinical presentation of AVRT is quite similar to AV-nodal reentrant tachycardias, the correct diagnosis is often facilitated by analyzing a standard 12-lead ECG at normal heart rate showing ventricular preexcitation. Curative catheter ablation of the AP represents the therapy of choice in symptomatic patients. This article is the fourth part of a series written to improve the professional education of young electrophysiologists. It explains pathophysiology, symptoms, and electrophysiological findings of an invasive EP study. It focusses on mapping and ablation of accessory pathways.

  7. The progressive onset of cholinergic and adrenergic control of heart rate during development in the green iguana, Iguana iguana.

    PubMed

    Sartori, Marina R; Leite, Cleo A C; Abe, Augusto S; Crossley, Dane A; Taylor, Edwin W

    2015-10-01

    The autonomic control of heart rate was studied throughout development in embryos of the green iguana, Iguana iguana by applying receptor agonists and antagonists of the parasympathetic and sympathetic systems. Acetylcholine (Ach) slowed or stopped the heart and atropine antagonized the response to Ach indicating the presence of muscarinic cholinoceptors on the heart of early embryos. However, atropine injections had no impact on heart rate until immediately before hatching, when it increased heart rate by 15%. This cholinergic tonus increased to 34% in hatchlings and dropped to 24% in adult iguanas. Although epinephrine was without effect, injection of propranolol slowed the heart throughout development, indicating the presence of β-adrenergic receptors on the heart of early embryos, possibly stimulated by high levels of circulating catecholamines. The calculated excitatory tonus varied between 33% and 68% until immediately before hatching when it fell to 25% and 29%, a level retained in hatchlings and adults. Hypoxia caused a bradycardia in early embryos that was unaffected by injection of atropine indicating that hypoxia has a direct effect upon the heart. In later embryos and hatchlings hypoxia caused a tachycardia that was unaffected by injection of atropine. Subsequent injection of propranolol reduced heart rate both uncovering a hypoxic bradycardia in late embryos and abolishing tachycardia in hatchlings. Hypercapnia was without effect on heart rate in late stage embryos and in hatchlings. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Nausea/vomiting · tachycardia · unintentional weight loss · Dx?

    PubMed

    Selen, Daryl J; Gilbert, Matthew P

    2017-02-01

    A 22-year-old woman presented to the emergency department (ED) with a 24-hour history of nausea, vomiting, diarrhea, generalized abdominal pain, and mild headache. She denied shortness of breath, chest pain, or anxiety, and didn't have a history of cardiac problems. The physical examination revealed tachycardia (heart rate, 135 beats/min) and a respiratory rate of 24 breaths per minute.

  9. The neuropathic postural tachycardia syndrome

    NASA Technical Reports Server (NTRS)

    Jacob, G.; Costa, F.; Shannon, J. R.; Robertson, R. M.; Wathen, M.; Stein, M.; Biaggioni, I.; Ertl, A.; Black, B.; Robertson, D.

    2000-01-01

    BACKGROUND: The postural tachycardia syndrome is a common disorder that is characterized by chronic orthostatic symptoms and a dramatic increase in heart rate on standing, but that does not involve orthostatic hypotension. Several lines of evidence indicate that this disorder may result from sympathetic denervation of the legs. METHODS: We measured norepinephrine spillover (the rate of entry of norepinephrine into the venous circulation) in the arms and legs both before and in response to exposure to three stimuli (the cold pressor test, sodium nitroprusside infusion, and tyramine infusion) in 10 patients with the postural tachycardia syndrome and in 8 age- and sex-matched normal subjects. RESULTS: At base line, the mean (+/-SD) plasma norepinephrine concentration in the femoral vein was lower in the patients with the postural tachycardia syndrome than in the normal subjects (135+/-30 vs. 215+/-55 pg per milliliter [0.80+/-0.18 vs. 1.27+/-0.32 nmol per liter], P=0.001). Norepinephrine spillover in the arms increased to a similar extent in the two groups in response to each of the three stimuli, but the increases in the legs were smaller in the patients with the postural tachycardia syndrome than in the normal subjects (0.001+/-0.09 vs. 0.12+/-0.12 ng per minute per deciliter of tissue [0.006+/-0.53 vs. 0.71+/-0.71 nmol per minute per deciliter] with the cold pressor test, P=0.02; 0.02+/-0.07 vs. 0.23+/-0.17 ng per minute per deciliter [0.12+/-0.41 vs. 1.36+/-1.00 nmol per minute per deciliter] with nitroprusside infusion, P=0.01; and 0.008+/-0.09 vs. 0.19+/-0.25 ng per minute per deciliter [0.05+/-0.53 vs. 1.12+/-1.47 nmol per minute per deciliter] with tyramine infusion, P=0.04). CONCLUSIONS: The neuropathic postural tachycardia syndrome results from partial sympathetic denervation, especially in the legs.

  10. Tachycardia in patients treated with clozapine versus antipsychotic long-acting injections.

    PubMed

    Nilsson, Björn M; Edström, Oscar; Lindström, Leif; Wernegren, Petter; Bodén, Robert

    2017-07-01

    Tachycardia is a known adverse effect during clozapine treatment. However, prevalence reported differs widely between studies and hitherto there are no studies comparing clozapine-treated patients with a similar control group. The present study was carried out to assess the prevalence of tachycardia in patients treated with clozapine and antipsychotic long-acting injections (LAI). Data on heart rate (HR), concomitant medication, and relevant anthropometric and laboratory measurements were collected for all clozapine-treated patients (n=174) in a defined catchment area and compared with data on patients treated with LAI (n=87). In total, 33% of patients on long-term clozapine treatment had tachycardia (HR>100) compared with 16% in the LAI group (P<0.001). The mean HR was 91 in the clozapine group and 82 in the LAI group (P<0.001). Clozapine dose correlated with HR. The majority of patients with HR more than 100 received no specific treatment for tachycardia. In conclusion, the prevalence of tachycardia was twice as high in patients treated with clozapine as in a similar patient group with severe schizophrenia spectrum disorder. The tachycardia was in many cases clinically unnoticed. Tachycardia during antipsychotic treatment is a common phenomenon that must be monitored for actively and, when noticed, further investigated and treated.

  11. THE EFFECTS OF SPINAL ANESTHESIA ON THE FETAL HEART RATE

    PubMed Central

    Downs, Howard S.; Morrison, Philip H.

    1963-01-01

    The effect of spinal anesthesia on fetal heart rate is due to maternal hypotension and subsequent fetal hypoxia. Maternal hypotension of 80 mm of mercury for five minutes almost always results in hypoxic fetal bradycardia. This bradycardia is gradual in onset, and may be preceded by a short period of fetal tachycardia. There is a lag in the return of fetal heart rate to normal after maternal blood pressure has normalized. Similar bradycardia has been observed in maternal syncope unassociated with anesthesia. Maternal hypotension should be prevented, and if it occurs should be corrected early. Administration of a vasopressor drug is the treatment of choice, with oxygen and fluids as indicated. ImagesFigure 1.Figure 3.Figure 4.Figure 5. PMID:14084683

  12. The role of the autonomic nervous system in the resting tachycardia of human hyperthyroidism.

    PubMed

    Maciel, B C; Gallo, L; Marin Neto, J A; Maciel, L M; Alves, M L; Paccola, G M; Iazigi, N

    1987-02-01

    The mechanisms that control resting heart rate in hyperthyroidism were evaluated in six patients before and after treatment with propylthiouracil. The patients were subjected to pharmacological blockade under resting conditions in two experimental sessions: first session, propranolol (0.2 mg/kg body weight); second session, atropine (0.04 mg/kg body weight) followed by propranolol (0.2 mg/kg body weight). All drugs were administered intravenously. Resting heart rate was significantly reduced from 100 +/- 6.5 beats/min to 72 +/- 2.5 beats/min (P less than 0.005) after clinical and laboratory control of the disease. After double blockade, intrinsic heart rate was reduced from 105 +/- 6.8 beats/min before treatment to 98 +/- 6.0 beats/min after treatment (P less than 0.025). The reduction in heart rate caused by propranolol was not significantly different before (-13 +/- 1.4 beats/min) and after (-9 +/- 1.0 beats/min) propylthiouracil. In contrast, atropine induced a higher elevation of heart rate after treatment (45 +/- 8.6 beats/min) than before treatment (26 +/- 4.0 beats/min). The present results suggest no appreciable participation of the sympathetic component of the autonomic nervous system in the tachycardia of hyperthyroidism, at least under the conditions of the present study. The small change observed in intrinsic heart rate, although significant, seems to indicate that this is not the most important mechanism involved in this tachycardia. Our results suggest that an important reduction in the efferent activity of the parasympathetic component participates in the mechanisms that modify resting heart rte in hyperthyroidism.

  13. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    NASA Technical Reports Server (NTRS)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  14. Junctional ectopic tachycardia after infant heart surgery: incidence and outcomes.

    PubMed

    Zampi, Jeffrey D; Hirsch, Jennifer C; Gurney, James G; Donohue, Janet E; Yu, Sunkyung; LaPage, Martin J; Hanauer, David A; Charpie, John R

    2012-12-01

    Junctional ectopic tachycardia (JET) is an arrhythmia observed almost exclusively after open heart surgery in children. Current literature on JET has not focused on patients at the highest risk of both developing and being negatively impacted by JET. The purpose of this study was to determine the overall incidence of JET in an infant patient cohort undergoing open cardiac surgery, to identify patient- and procedure-related factors associated with developing JET, and to assess the clinical impact of JET on patient outcomes. We performed a nested case-control study from the complete cohort of patients at our institution younger than 1 year of age who underwent open heart surgery between 2005 and 2010. JET patients were compared with an age matched control group undergoing open heart surgery without JET regarding potential risk factors and outcomes. The overall incidence of JET in infants after open cardiac surgery was 14.3 %. From multivariate analyses, complete repair of tetralogy of Fallot [adjusted odds ratio (AOR) 2.0, 95 % CI 1.12-3.57] and longer aortic cross clamp times (AOR 1.02, 95 % CI 1.01-1.03) increased the risk of developing JET. Patients with JET had longer length of intubation, intensive care unit stays, and total length of hospitalization, and were more likely to require extracorporeal membrane oxygenation support (13 vs. 4.3 %). JET is a common postoperative arrhythmia in infants after open heart operations. Both anatomic substrate and surgical procedure contribute to the overall risk of developing JET. Developing JET is associated with worse clinical outcomes.

  15. Utility of Time and Frequency Domain Parameters of Heart Rate Variability in the Context of Autonomic Disorders Characterized by Orthostatic Dysfunction.

    PubMed

    Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt

    2018-03-01

    The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.

  16. Detection of a Heart Defect in the Fetus

    MedlinePlus

    ... problems : There is a wide range of acceptable fetal heart rates (normal is between 120 and 160 but many ... usually go away shortly after birth. More important fetal heart problems include tachycardia (hear rate too fast) and bradycardia (heart rate too slow). ...

  17. Non stationary analysis of heart rate variability during the obstructive sleep apnea.

    PubMed

    Méndez, M O; Bianchi, A M; Cerutti, S

    2004-01-01

    Characteristic fluctuations of the heart rate are found during obstructive sleep apnea (OSA), bradycardia in apneonic phase and tachycardia at the recovery of ventilation. In order to assess its autonomic response, in this study, the time-frequency distribution of Born-Jordan and evolutive Poincare plots are used. From Physionet was taken a database with records of ECG and respiratory signals. During the OSA all spectral indexes presented oscillations correspondent to the changes between brady and tachycardia of the RR intervals as well as greater values than during control epochs. Born-Jordan distribution and evolutive Poincare plots could help to characterize and develop an index for the evaluation of OSA. Very low frequency could also be a good index of OSA.

  18. Tachycardia-Induced Right Heart Failure and Severe Tricuspid Regurgitation That Improved with Medication.

    PubMed

    Yang, Young Ae; Yang, Dong Heon; Kim, Hong Nyun; Kwon, Sang Hoon; Jang, Se Young; Bae, Myung Hwan; Lee, Jang Hoon; Chae, Shung Chull

    2015-12-01

    Secondary tricuspid regurgitation (TR) primarily develops due to left heart failure or primary pulmonary diseases. Tricuspid annular dilation, which is commonly caused by right ventricular volume and pressure overload followed by right ventricle dilation, is believed to be the main mechanism underlying secondary TR. It is reported that once the tricuspid annulus is dilated, its size cannot spontaneously return to normal, and it may continue to dilate. These reports also suggest the use of an aggressive surgical approach for secondary TR. In the present report, we describe a case of tachycardia-induced severe TR that was completely resolved without the need for surgery.

  19. Perinatal sulfur dioxide exposure alters brainstem parasympathetic control of heart rate.

    PubMed

    Woerman, Amanda L; Mendelowitz, David

    2013-07-01

    Sulfur dioxide (SO₂) is an air pollutant that impedes neonatal development and induces adverse cardiorespiratory health effects, including tachycardia. Here, an animal model was developed that enabled characterization of (i) in vivo alterations in heart rate and (ii) altered activity in brainstem neurons that control heart rate after perinatal SO₂ exposure. Pregnant Sprague-Dawley dams and their pups were exposed to 5 parts per million SO₂ for 1 h daily throughout gestation and 6 days postnatal. Electrocardiograms were recorded from pups at 5 days postnatal to examine changes in basal and diving reflex-evoked changes in heart rate following perinatal SO₂ exposure. In vitro studies employed whole-cell patch-clamp electrophysiology to examine changes in neurotransmission to cardiac vagal neurons within the nucleus ambiguus upon SO₂ exposure using a preparation that maintains fictive inspiratory activity recorded from the hypoglossal rootlet. Perinatal SO₂ exposure increased heart rate and blunted the parasympathetic-mediated diving reflex-evoked changes in heart rate. Neither spontaneous nor inspiratory-related inhibitory GABAergic or glycinergic neurotransmission to cardiac vagal neurons was altered by SO₂ exposure. However, excitatory glutamatergic neurotransmission was decreased by 51.2% upon SO₂ exposure. This diminished excitatory neurotransmission was tetrodotoxin-sensitive, indicating SO₂ exposure impaired the activity of preceding glutamatergic neurons that synapse upon cardiac vagal neurons. Diminished glutamatergic, but unaltered inhibitory neurotransmission to cardiac vagal neurons provides a mechanism for the observed SO₂-induced elevated heart rate via an impairment of brainstem cardioinhibitory parasympathetic activity to the heart.

  20. Leptin decreases heart rate associated with increased ventricular repolarization via its receptor.

    PubMed

    Lin, Yen-Chang; Huang, Jianying; Hileman, Stan; Martin, Karen H; Hull, Robert; Davis, Mary; Yu, Han-Gang

    2015-11-15

    Leptin has been proposed to modulate cardiac electrical properties via β-adrenergic receptor activation. The presence of leptin receptors and adipocytes in myocardium raised a question as to whether leptin can directly modulate cardiac electrical properties such as heart rate and QT interval via its receptor. In this work, the role of local direct actions of leptin on heart rate and ventricular repolarization was investigated. We identified the protein expression of leptin receptors at cell surface of sinus node, atrial, and ventricular myocytes isolated from rat heart. Leptin at low doses (0.1-30 μg/kg) decreased resting heart rate; at high doses (150-300 μg/kg), leptin induced a biphasic effect (decrease and then increase) on heart rate. In the presence of high-dose propranolol (30 mg/kg), high-dose leptin only reduced heart rate and sometimes caused sinus pauses and ventricular tachycardia. The leptin-induced inhibition of resting heart rate was fully reversed by leptin antagonist. Leptin also increased heart rate-corrected QT interval (QTc), and leptin antagonist did not. In isolated ventricular myocytes, leptin (0.03-0.3 μg/ml) reversibly increased the action potential duration. These results supported our hypothesis that in addition to indirect pathway via sympathetic tone, leptin can directly decrease heart rate and increase QT interval via its receptor independent of β-adrenergic receptor stimulation. During inhibition of β-adrenergic receptor activity, high concentration of leptin in myocardium can cause deep bradycardia, prolonged QT interval, and ventricular arrhythmias. Copyright © 2015 the American Physiological Society.

  1. Leptin decreases heart rate associated with increased ventricular repolarization via its receptor

    PubMed Central

    Lin, Yen-Chang; Huang, Jianying; Hileman, Stan; Martin, Karen H.; Hull, Robert; Davis, Mary

    2015-01-01

    Leptin has been proposed to modulate cardiac electrical properties via β-adrenergic receptor activation. The presence of leptin receptors and adipocytes in myocardium raised a question as to whether leptin can directly modulate cardiac electrical properties such as heart rate and QT interval via its receptor. In this work, the role of local direct actions of leptin on heart rate and ventricular repolarization was investigated. We identified the protein expression of leptin receptors at cell surface of sinus node, atrial, and ventricular myocytes isolated from rat heart. Leptin at low doses (0.1–30 μg/kg) decreased resting heart rate; at high doses (150–300 μg/kg), leptin induced a biphasic effect (decrease and then increase) on heart rate. In the presence of high-dose propranolol (30 mg/kg), high-dose leptin only reduced heart rate and sometimes caused sinus pauses and ventricular tachycardia. The leptin-induced inhibition of resting heart rate was fully reversed by leptin antagonist. Leptin also increased heart rate-corrected QT interval (QTc), and leptin antagonist did not. In isolated ventricular myocytes, leptin (0.03–0.3 μg/ml) reversibly increased the action potential duration. These results supported our hypothesis that in addition to indirect pathway via sympathetic tone, leptin can directly decrease heart rate and increase QT interval via its receptor independent of β-adrenergic receptor stimulation. During inhibition of β-adrenergic receptor activity, high concentration of leptin in myocardium can cause deep bradycardia, prolonged QT interval, and ventricular arrhythmias. PMID:26408544

  2. Associations among left ventricular systolic function, tachycardia, and cardiac preload in septic patients.

    PubMed

    Lanspa, Michael J; Shahul, Sajid; Hersh, Andrew; Wilson, Emily L; Olsen, Troy D; Hirshberg, Eliotte L; Grissom, Colin K; Brown, Samuel M

    2017-12-01

    In sepsis, tachycardia may indicate low preload, adrenergic stimulation, or both. Adrenergic overstimulation is associated with septic cardiomyopathy. We sought to determine whether tachycardia was associated with left ventricular longitudinal strain, a measure of cardiac dysfunction. We hypothesized an association would primarily exist in patients with high preload. We prospectively observed septic patients admitted to three study ICUs, who underwent early transthoracic echocardiography. We measured longitudinal strain using speckle tracking echocardiography and estimated preload status with an echocardiographic surrogate (E/e'). We assessed correlation between strain and heart rate in patients with low preload (E/e' < 8), intermediate preload (E/e' 8-14), and high preload (E/e' > 14), adjusting for disease severity and vasopressor dependence. We studied 452 patients, of whom 298 had both measurable strain and preload. Abnormal strain (defined as >-17%) was present in 54%. Patients with abnormal strain had higher heart rates (100 vs. 93 beat/min, p = 0.001). After adjusting for vasopressor dependence, disease severity, and cardiac preload, we observed an association between heart rate and longitudinal strain (β = 0.05, p = 0.003). This association persisted among patients with high preload (β = 0.07, p = 0.016) and in patients with shock (β = 0.07, p = 0.01), but was absent in patients with low or intermediate preload and those not in shock. Tachycardia is associated with abnormal left ventricular strain in septic patients with high preload. This association was not apparent in patients with low or intermediate preload.

  3. Safety of transvenous low energy cardioversion of atrial fibrillation in patients with a history of ventricular tachycardia: effects of rate and repolarization time on proarrhythmic risk.

    PubMed

    Simons, G R; Newby, K H; Kearney, M M; Brandon, M J; Natale, A

    1998-02-01

    The objective of this study was to assess the safety and efficacy of transvenous low energy cardioversion of atrial fibrillation in patients with ventricular tachycardia and atrial fibrillation and to study the mechanisms of proarrhythmia. Previous studies have demonstrated that cardioversion of atrial fibrillation using low energy, R wave synchronized, direct current shocks applied between catheters in the coronary sinus and right atrium is feasible. However, few data are available regarding the risk of ventricular proarrhythmia posed by internal atrial defibrillation shocks among patients with ventricular arrhythmias or structural heart disease. Atrial defibrillation was performed on 32 patients with monomorphic ventricular tachycardia and left ventricular dysfunction. Shocks were administered during atrial fibrillation (baseline shocks), isoproterenol infusion, ventricular pacing, ventricular tachycardia, and atrial pacing. Baseline shocks were also administered to 29 patients with a history of atrial fibrillation but no ventricular arrhythmias. A total of 932 baseline shocks were administered. No ventricular proarrhythmia was observed after well-synchronized baseline shocks, although rare inductions of ventricular fibrillation occurred after inappropriate T wave sensing. Shocks administered during wide-complex rhythms (ventricular pacing or ventricular tachycardia) frequently induced ventricular arrhythmias, but shocks administered during atrial pacing at identical ventricular rates did not cause proarrhythmia. The risk of ventricular proarrhythmia after well-synchronized atrial defibrillation shocks administered during narrow-complex rhythms is low, even in patients with a history of ventricular tachycardia. The mechanism of proarrhythmia during wide-complex rhythms appears not to be related to ventricular rate per se, but rather to the temporal relationship between shock delivery and the repolarization time of the previous QRS complex.

  4. Frequency and irregularity of heart rate in drivers suspected of driving under the influence of cannabis.

    PubMed

    Khiabani, Hassan Z; Mørland, Jørg; Bramness, Jørgen G

    2008-12-01

    Delta 9-tetrahydrocannabinol (THC) is the major active component of cannabis. Cardiovascular effects of THC have previously been reported: tachycardia after intake, but also bradycardia at higher doses. The purpose of this study was, firstly, to investigate the frequency and irregularity of heart rate in a group of cannabis users in their natural surroundings. We also compared THC-positive drivers with a regular pulse with THC-positive drivers with an irregular pulse. The division of Forensic Toxicology and Drug Abuse (DFTDA) at the Norwegian Institute of Public Heath analyzes blood samples from all drivers suspected of driving under the influence of drugs. We studied pulse rate and regularity in 502 THC-positive drivers who tested negative for other substances. As a control group, we randomly selected 125 drug-negative cases from the database of the DFTDA; no alcohol, narcotics, or medicinal drugs of abuse were detected. The Delta9-THC-positive drivers had a higher mean pulse rate than the control group [82.8 beats/min (SD 16.3) versus 75.6 beats/min (SD 9.2)] and more cases with tachycardia were detected in the Delta9-THC-positive group (19.4% versus 1.6%). There was only one driver with an irregular heart beat in the control group, while there were nine among the Delta9-THC-positive drivers. The drivers with an irregular pulse were over-represented amongst those with the lowest blood Delta9-THC concentrations. This report represents a large study of subjects in a real-life situation and includes observations on pulse frequency, regularity, and blood Delta9-THC concentration. A substantial fraction of Delta9-THC-positive drivers had tachycardia, but there was no correlation between blood Delta9-THC concentration and pulse rate in the present study. We had no further diagnostic information on the cause of the pulse irregularities, but our results indicate that occasional users of cannabis tend to have irregular heart rates at low THC concentrations and at low

  5. Perinatal sulfur dioxide exposure alters brainstem parasympathetic control of heart rate

    PubMed Central

    Woerman, Amanda L.; Mendelowitz, David

    2013-01-01

    Aims Sulfur dioxide (SO2) is an air pollutant that impedes neonatal development and induces adverse cardiorespiratory health effects, including tachycardia. Here, an animal model was developed that enabled characterization of (i) in vivo alterations in heart rate and (ii) altered activity in brainstem neurons that control heart rate after perinatal SO2 exposure. Methods and results Pregnant Sprague–Dawley dams and their pups were exposed to 5 parts per million SO2 for 1 h daily throughout gestation and 6 days postnatal. Electrocardiograms were recorded from pups at 5 days postnatal to examine changes in basal and diving reflex-evoked changes in heart rate following perinatal SO2 exposure. In vitro studies employed whole-cell patch-clamp electrophysiology to examine changes in neurotransmission to cardiac vagal neurons within the nucleus ambiguus upon SO2 exposure using a preparation that maintains fictive inspiratory activity recorded from the hypoglossal rootlet. Perinatal SO2 exposure increased heart rate and blunted the parasympathetic-mediated diving reflex-evoked changes in heart rate. Neither spontaneous nor inspiratory-related inhibitory GABAergic or glycinergic neurotransmission to cardiac vagal neurons was altered by SO2 exposure. However, excitatory glutamatergic neurotransmission was decreased by 51.2% upon SO2 exposure. This diminished excitatory neurotransmission was tetrodotoxin-sensitive, indicating SO2 exposure impaired the activity of preceding glutamatergic neurons that synapse upon cardiac vagal neurons. Conclusions Diminished glutamatergic, but unaltered inhibitory neurotransmission to cardiac vagal neurons provides a mechanism for the observed SO2-induced elevated heart rate via an impairment of brainstem cardioinhibitory parasympathetic activity to the heart. PMID:23504550

  6. Chronic baroreflex activation restores spontaneous baroreflex control and variability of heart rate in obesity-induced hypertension

    PubMed Central

    Iliescu, Radu; Tudorancea, Ionut; Irwin, Eric D.

    2013-01-01

    The sensitivity of baroreflex control of heart rate is depressed in subjects with obesity hypertension, which increases the risk for cardiac arrhythmias. The mechanisms are not fully known, and there are no therapies to improve this dysfunction. To determine the cardiovascular dynamic effects of progressive increases in body weight leading to obesity and hypertension in dogs fed a high-fat diet, 24-h continuous recordings of spontaneous fluctuations in blood pressure and heart rate were analyzed in the time and frequency domains. Furthermore, we investigated whether autonomic mechanisms stimulated by chronic baroreflex activation and renal denervation—current therapies in patients with resistant hypertension, who are commonly obese—restore cardiovascular dynamic control. Increases in body weight to ∼150% of control led to a gradual increase in mean arterial pressure to 17 ± 3 mmHg above control (100 ± 2 mmHg) after 4 wk on the high-fat diet. In contrast to the gradual increase in arterial pressure, tachycardia, attenuated chronotropic baroreflex responses, and reduced heart rate variability were manifest within 1–4 days on high-fat intake, reaching 130 ± 4 beats per minute (bpm) (control = 86 ± 3 bpm) and ∼45% and <20%, respectively, of control levels. Subsequently, both baroreflex activation and renal denervation abolished the hypertension. However, only baroreflex activation effectively attenuated the tachycardia and restored cardiac baroreflex sensitivity and heart rate variability. These findings suggest that baroreflex activation therapy may reduce the risk factors for cardiac arrhythmias as well as lower arterial pressure. PMID:23913707

  7. The predictive value of resting heart rate following osmotherapy in brain injury: back to basics.

    PubMed

    Hasanpour Mir, Mahsa; Yousefshahi, Fardin; Abdollahi, Mohammad; Ahmadi, Arezoo; Nadjafi, Atabak; Mojtahedzadeh, Mojtaba

    2012-12-30

    The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia.To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury.

  8. Left septal atrial tachycardia after open-heart surgery: relevance to surgical approach, anatomical and electrophysiological characteristics associated with catheter ablation, and procedural outcomes.

    PubMed

    Adachi, Toru; Yoshida, Kentaro; Takeyasu, Noriyuki; Masuda, Keita; Sekiguchi, Yukio; Sato, Akira; Tada, Hiroshi; Nogami, Akihiko; Aonuma, Kazutaka

    2015-02-01

    Septal atrial tachycardia (AT) can occur in patients without structural heart disease and in patients with previous catheter ablation of atrial fibrillation. We aimed to assess septal AT that occurs after open-heart surgery. This study comprised 20 consecutive patients undergoing catheter ablation of macroreentrant AT after open-heart surgery. Relevance to surgical approach, mechanisms, anatomic and electrophysiological characteristics, and outcomes were assessed. Septal AT was identified in 7 patients who had all undergone mitral valve surgery. All septal ATs were localized in the left atrial septum, whereas 10 of 13 nonseptal ATs originated from the right atrium. Patients with left septal AT had a thicker fossa ovalis (median, 4.0; 25th-75th percentile, 3.6-4.2 versus 2.3; 1.6-2.6 mm; P=0.006) and broader area of low voltage (<0.3 mV) in the septum than patients with nonseptal AT (82; 76-89 versus 31; 28%-36%; P=0.02). Repeated gradual prolongations of the tachycardia cycle length without change of the septal circuit were observed in all patients with septal AT (70; 63-100 versus 15; 10-40 ms; P=0.0008). Although ablation terminated all ATs, recurrence of targeted ATs was more frequent in patients with left septal AT during 30-month follow-up (71 versus 0%; P=0.001). Left septal AT after open-heart surgery was characterized by a thicker septum, more scar burden in the septum, and repeated prolongations of the tachycardia cycle length during ablation. Such an arrhythmogenic substrate may interfere with transmural lesion formation by ablation and may account for higher likelihood of recurrence of left septal AT. © 2014 American Heart Association, Inc.

  9. Ventricular Tachycardia or not? An Unexpected Reason of Wide QRS Complex Tachycardia in a Young Healthy Man: Sodium Bicarbonate.

    PubMed

    Eyuboglu, Mehmet

    2016-10-01

    Ventricular tachycardia (VT) is life-threatening subgroup of wide QRS complex tachycardia (WCT). VT is usually associated with structural heart diseases, but it can occur in the absence of any cardiovascular diseases. Adverse cardiac effect of sodium bicarbonate in healthy subjects is not well described. A 30-year-old healthy man with excessive intake of sodium bicarbonate-related VT is presented. He was using sodium bicarbonate during last 2 months to lose weight. He has no risk factors and any cardiovascular or systemic diseases. After intravenous administration of amiodarone, tachycardia ended and his rhythm converted to sinus rhythm with normal electrocardiogram. Patient is asymptomatic, and no VT was observed without any medications at 1 year of follow-up.

  10. Focal Atrial Tachycardia Arising from the Inferior Vena Cava

    PubMed Central

    Lim, Yeong-Min; Uhm, Jae-Sun

    2017-01-01

    The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006

  11. [Correlation of heart rate variability with SYNTAX II on chronic angina].

    PubMed

    Castro-de la Torre, Tatiana Chantal; Amador-Licona, Norma; Bernal-Ruíz, Enrique

    2017-01-01

    The heart rate variability (HRV) is a prognostic value of cardiovascular risk. It is unknown the correlation between HRV and coronary severity on patients with chronic angina. The objective was to determine the correlation between HRV and the SYNTAX II score in chronic angina. Cross-sectional study in patients of 18 years or older with stable angina and indication of coronary angiography who went to a third level center. The SYNTAX II score was established by using coronary angiography, while HRV was obtained by a 24-hour Holter ECG. The correlation between SYNTAX II and HRV was performed with Pearson's test. Values of SDNN < 100 ms and RMSSD < 15 ms were considered risk factors. 61 patients were included. 45 had a decreased value of SDNN (73.77%) and eight had a decreased value of RMSSD (13.11%). There was no correlation between HRV and SYNTAX II score. There were more events of ventricular tachycardia in the group of patients with low SDNN than in those with normal SDNN (15.5% vs. 0.0%; p = 0.04). There was no correlation between HRV and the severity of coronary artery disease in stable chronic ischemic heart disease. However, those patients with low HRV showed more events of ventricular tachycardia.

  12. The predictive value of resting heart rate following osmotherapy in brain injury: back to basics

    PubMed Central

    2012-01-01

    Background The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia. To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). Method By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. Results After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Conclusion Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury. PMID:23351393

  13. Tachycardia may prognosticate life- or organ-threatening diseases in children with abdominal pain.

    PubMed

    Hayakawa, Itaru; Sakakibara, Hiroshi; Atsumi, Yukari; Hataya, Hiroshi; Terakawa, Toshiro

    2017-06-01

    Abdominal pain is common in children, but expeditious diagnosis of life- or organ-threatening diseases can be challenging. An evidence-based definition of tachycardia in children was established recently, but its diagnostic utility has not yet been studied. To test the hypothesis that abdominal pain with tachycardia may pose a higher likelihood of life- or organ-threatening diseases in children. A nested case-control study was conducted in a pediatric emergency department in 2013. Tachycardia was defined as a resting heart rate of more than 3 standard deviations above the average for that age. Life- or organ-threatening diseases were defined as "disorders that might result in permanent morbidity or mortality without appropriate intervention." A triage team recorded vital signs before emergency physicians attended patients. Patients with tachycardia (cases) and without tachycardia (controls) were systematically matched for age, sex, and month of visit. The groups were compared for the presence of life- or organ-threatening diseases. There were 1683 visits for abdominal pain, 1512 of which had vital signs measured at rest. Eighty-three patients experienced tachycardia, while 1429 did not. Fifty-eight cases and 58 controls were matched. Life- or organ-threatening diseases were more common in the case group (19%) than the control group (5%, p=0.043). The relative risk of tachycardia to the presence of the diseases was 3.7 (95% confidence interval 1.2-12.0). Tachycardia significantly increased the likelihood of life- or organ-threatening diseases. Tachycardia in children with abdominal pain should alert emergency physicians to the possibility of serious illness. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    PubMed Central

    Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01

    Background: Decreased heart rate variability (HRV) has been associated with future cardiac morbidity and mortality and is often used as a marker of altered cardiac autonomic balance in studies of health effects of airborne particulate matter. Fewer studies have evaluated associations between air pollutants and cardiac arrhythmia. Objectives: We examined relationships between cardiac arrhythmias, HRV, and exposures to airborne particulate matter. Methods: We measured HRV and arrhythmia with ambulatory electrocardiograms in a cohort panel study for up to 235 hr per participant among 50 nonsmokers with coronary artery disease who were ≥ 71 years of age and living in four retirement communities in the Los Angeles, California, Air Basin. Exposures included hourly outdoor gases, hourly traffic-related and secondary organic aerosol markers, and daily size-fractionated particle mass. We used repeated measures analyses, adjusting for actigraph-derived physical activity and heart rate, temperature, day of week, season, and community location. Results: Ventricular tachycardia was significantly increased in association with increases in markers of traffic-related particles, secondary organic carbon, and ozone. Few consistent associations were observed for supraventricular tachycardia. Particulates were significantly associated with decreased ambulatory HRV only in the 20 participants using ACE (angiotensin I–converting enzyme) inhibitors. Conclusions: Although these data support the hypothesis that particulate exposures may increase the risk of ventricular tachycardia for elderly people with coronary artery disease, HRV was not associated with exposure in most of our participants. These results are consistent with previous findings in this cohort for systemic inflammation, blood pressure, and ST segment depression. Citation: Bartell SM, Longhurst J, Tjoa T, Sioutas C, Delfino RJ. 2013. Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in

  15. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Electrophysiological actions of somatostatin on the atrioventricular junction in sinus rhythm and reentry tachycardia.

    PubMed

    Webb, S C; Krikler, D M; Hendry, W G; Adrian, T E; Bloom, S R

    1986-09-01

    Because somatostatin, a neuroregulatory peptide, is found in abundance in the atria and atrioventricular node, its electrophysiological and antiarrhythmic properties were compared with those of verapamil in ten patients with paroxysmal atrioventricular tachycardia. During sinus rhythm, intravenous somatostatin slowed the heart rate whereas verapamil increased it. Though both agents prolonged atrioventricular conduction time and refractoriness, verapamil was more potent. They were equally effective at terminating reentry atrioventricular tachycardia, restoring sinus rhythm in six of seven patients. Whereas verapamil consistently blocked conduction in the atrioventricular node, somatostatin usually induced ventricular extrasystoles at the time of conversion. Somatostatin may have physiological importance in the neurohumoral control of cardiac impulse formation and conduction.

  17. Surgical treatment for ectopic atrial tachycardia.

    PubMed

    Graffigna, A; Vigano, M; Pagani, F; Salerno, G

    1992-08-01

    Atrial tachycardia is an infrequent but potentially dangerous arrhythmia which often determines cardiac enlargement. Surgical ablation of the arrhythmia is effective and safe, provided a careful atrial mapping is performed and the surgical technique is tailored to the individual focus location. Eight patients underwent surgical ablation of ectopic atrial tachycardia between 1977 and 1990. Different techniques were adopted for each patient according to the anatomical location of the focus and possibly associated arrhythmias. Whenever possible, a closed heart procedure was chosen. In 1 patient a double focal origin was found and treated by separate procedures. In 1 patient with ostium secundum atrial septal defect and atrial flutter, surgical isolation of the right appendage and the ectopic focus was performed. In all patients ectopic atrial tachycardia was ablated with maintenance of the sinoatrial and atrioventricular nodal function as well as internodal conduction. In follow-up up to December 1991, no recurrency was recorded.

  18. Idiopathic Paroxysmal Ventricular Tachycardia in Infants and Children

    ERIC Educational Resources Information Center

    Hernandez, Antonio; And Others

    1975-01-01

    Laboratory tests including blood count serum electrolyte measures, and electroencephalograms were performed on seven children ages 1 day to 18 years with recurrent attacks of rapid heart action known as idiopathic paroxysmal ventricular tachycardia. (CL)

  19. Utility of 12-lead electrocardiogram for differentiating paroxysmal supraventricular tachycardias in dogs.

    PubMed

    Santilli, R A; Perego, M; Crosara, S; Gardini, F; Bellino, C; Moretti, P; Spadacini, G

    2008-01-01

    The 12-lead surface ECG is validated for differentiating supraventricular tachycardias (SVT) in humans. Despite the description of SVT in veterinary medicine, no studies have analyzed the electrocardiographic features of this type of arrhythmias in dogs. To describe the specific electrocardiographic criteria used to differentiate the most common SVT in dogs. Twenty-three dogs examined at Clinica Veterinaria Malpensa for SVT with the mechanism documented by electrophysiologic studies (EPS). Twelve-lead electrocardiographic variables obtained from 14 dogs with orthodromic atrioventricular reciprocating tachycardia (OAVRT) and 9 dogs with focal atrial tachycardia (FAT) were compared. Dogs with FAT had faster heart rates (278 +/- 62 versus 229 +/- 42 bpm; P= .049) and less QRS alternans (33 versus 86%; P= .022). P waves appeared during tachycardia in 22 dogs, with a superior axis in 100% of OAVRT and 22% of FAT (P < .001). OAVRT was characterized by a shorter RP interval (85.0 +/- 16.8 versus 157.1 +/- 37.3 ms; P < .001) and smaller RP/PR ratio (0.60 +/- 0.18 versus 1.45 +/- 0.52; P < .001). Repolarization anomalies were present in 64% of OAVRT and no FAT (P < .001). Multivariate analysis identified QRS alternans and a positive P wave in aVR during tachycardia as independent predictors of arrhythmia type. Electrocardiographic criteria used in people for differentiating SVT can also be applied in dogs.

  20. Catheter ablation for premature ventricular contractions and ventricular tachycardia in patients with heart failure.

    PubMed

    Kumar, Saurabh; Stevenson, William G; John, Roy M

    2014-09-01

    Ventricular arrhythmias (VA) are a significant contributor to morbidity and mortality in patients with heart failure (HF). Implantable cardioverter defibrillators are effective in reducing mortality, but do not prevent arrhythmia recurrence. There is increasing recognition that frequent premature ventricular contractions or repetitive ventricular tachycardia may also lead to new onset ventricular dysfunction or deterioration of ventricular function in patients with pre-existing HF. Suppression of the arrhythmia may lead to recovery of ventricular function. Catheter ablation has emerged as a safe and effective treatment option for reducing arrhythmia recurrence and for suppression of PVCs but its efficacy is governed by the nature of the arrhythmias, the underlying HF substrate and the accessibility of the arrhythmia substrates to ablation.

  1. Concomitant Wolff-Parkinson-White and Atrioventricular Nodal Reentrant Tachycardia: Which Pathway to Ablate?

    PubMed

    Sarsam, Sinan; Sidiqi, Ibrahim; Shah, Dipak; Zughaib, Marcel

    2015-12-11

    Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common form of supraventricular tachycardia. In contrast, Wolff-Parkinson-White (WPW) pattern consists of an accessory pathway, which may result in the development of ventricular arrhythmias. Frequent tachycardia caused by AVNRT and accessory pathways may play a role in left ventricular systolic dysfunction. A 54-year-old man presented with palpitations and acute decompensated congestive heart failure. His baseline EKG showed Wolff-Parkinson-White (WPW) pattern. While hospitalized, he had an episode of atrioventricular nodal reentrant tachycardia (AVNRT). He underwent radiofrequency catheter ablation for AVNRT, and his accessory pathway was also ablated even though its conduction was found to be weak. He was clinically doing well on follow-up visit, with resolution of his heart failure symptoms and normalization of left ventricular function on echocardiography. This case raises the question whether the accessory pathway plays a role in the development of systolic dysfunction, and if there is any role for ablation in patients with asymptomatic WPW pattern.

  2. Heart rate turbulence predicts ICD-resistant mortality in ischaemic heart disease.

    PubMed

    Marynissen, Thomas; Floré, Vincent; Heidbuchel, Hein; Nuyens, Dieter; Ector, Joris; Willems, Rik

    2014-07-01

    In high-risk patients, implantable cardioverter-defibrillators (ICDs) can convert the mode of death from arrhythmic to pump failure death. Therefore, we introduced the concept of 'ICD-resistant mortality' (IRM), defined as death (a) without previous appropriate ICD intervention (AI), (b) within 1 month after the first AI, or (c) within 1 year after the initial ICD implantation. Implantable cardioverter-defibrillator implantation in patients with a high risk of IRM should be avoided. Implantable cardioverter-defibrillator patients with ischaemic heart disease were included if a digitized 24 h Holter was available pre-implantation. Demographic, electrocardiographic, echocardiographic, and 24 h Holter risk factors were collected at device implantation. The primary endpoint was IRM. Cox regression analyses were used to test the association between predictors and outcome. We included 130 patients, with a mean left ventricular ejection fraction (LVEF) of 33.6 ± 10.3%. During a follow-up of 52 ± 31 months, 33 patients died. There were 21 cases of IRM. Heart rate turbulence (HRT) was the only Holter parameter associated with IRM and total mortality. A higher New York Heart Association (NYHA) class and a lower body mass index were the strongest predictors of IRM. Left ventricular ejection fraction predicted IRM on univariate analysis, and was the strongest predictor of total mortality. The only parameter that predicted AI was non-sustained ventricular tachycardia. Implantable cardioverter-defibrillator implantation based on NYHA class and LVEF leads to selection of patients with a higher risk of IRM and death. Heart rate turbulence may have added value for the identification of poor candidates for ICD therapy. Available Holter parameters seem limited in their ability to predict AI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2013. For permissions please email: journals.permissions@oup.com.

  3. Incessant atrial tachycardias in a dog with tricuspid dysplasia. Clinical management and electrophysiology.

    PubMed

    de Madron, E; Kadish, A; Spear, J F; Knight, D H

    1987-01-01

    In a dog, tricuspid regurgitation due to congenital tricuspid dysplasia resulted in extreme right heart enlargement and right heart failure. Incessant supraventricular tachycardias were present, requiring the intravenous administration of verapamil to reduce the ventricular rate. Oral therapy using a combination of verapamil and quinidine was partially effective in controlling the ventricular rate during the following week. At that time, electrophysiologic studies were performed. They revealed that a succession of several atrial tachycardias with different cycle lengths, including one episode of atrial flutter, was present. Atrial activity was spanning the majority of the cycle length in all these arrhythmias. Epicardial mapping was performed during the atrial flutter. This enabled the detection of a depolarization wave-front traveling counterclockwise from the dorsolateral right atrium toward the right appendage, following the tricuspid valve annulus. No areas of abnormal conduction were detected. Because programmed electric stimulation maneuvers could not be performed, definitive conclusions about the mechanism of the arrhythmia could not be drawn. The two most likely possibilities were circus movement using part of the dilated tricuspid valve annulus as an anatomic barrier or a leading circle type of re-entry.

  4. Supraventricular tachycardia induced by chocolate: is chocolate too sweet for the heart?

    PubMed

    Parasramka, Saurabh; Dufresne, Alix

    2012-09-01

    Conflicting studies have been published concerning the association between chocolate and cardiovascular diseases. Fewer articles have described the potential arrhythmogenic risk related to chocolate intake. We present a case of paroxysmal supraventricular tachycardia in a woman after consumption of large quantity of chocolate. A 53-year-old woman with no significant medical history presented to us with complaints of palpitations and shortness of breath after consuming large amounts of chocolate. Electrocardiogram showed supraventricular tachycardia at 165 beats per minute, which was restored to sinus rhythm after adenosine bolus injection. Electrophysiology studies showed atrioventricular nodal reentry tachycardia, which was treated with radiofrequency ablation. Chocolate contains caffeine and theobromine, which are methylxanthines and are competitive antagonists of adenosine and can have arrhythmogenic potential. Our case very well describes an episode of tachycardia precipitated by large amount of chocolate consumption in a patient with underlying substrate. There are occasional case reports describing association between chocolate, caffeine, and arrhythmias. A large Danish study, however, did not find any association between amount of daily caffeine consumption and risk of arrhythmia.

  5. Lacosamide-Induced Recurrent Ventricular Tachycardia in the Acute Care Setting.

    PubMed

    Berei, Theodore J; Lillyblad, Matthew P; Almquist, Adrian K

    2018-04-01

    Lacosamide is a new-generation antiepileptic drug (AED) most commonly used adjunctively in the setting of partial-onset seizures refractory to traditional therapy. We describe the first case report, to our knowledge, of a patient who developed recurrent, sustained ventricular tachycardia with multiple administrations of lacosamide in an acute setting. A 70-year-old woman with a history significant for valvular heart disease was admitted to the inpatient cardiology service for worsening heart failure. On hospital day 7, she received a bioprosthetic aortic valve. Prior to surgery and immediately after, the patient's electrocardiogram (ECG) was normal. After developing multiple generalized tonic-clonic seizures refractory to levetiracetam, fosphenytoin, and valproic acid, the decision was made to initiate lacosamide. Two hours following the second lacosamide dose, the patient developed a wide complex QRS that transitioned into sustained ventricular tachycardia requiring electrical cardioversion. Sustained ventricular tachycardia occurred again, just hours after the third dose of lacosamide was given. Following cessation of lacosamide, the patient's QRS interval normalized and has since had no documented episodes of ventricular tachycardia. Clinicians should be aware of the potential for life-threatening rhythmic disturbances in patients initiated on lacosamide and the need for vigilant ECG, electrolyte, and drug-drug monitoring.

  6. Electrophysiological actions of somatostatin on the atrioventricular junction in sinus rhythm and reentry tachycardia.

    PubMed Central

    Webb, S C; Krikler, D M; Hendry, W G; Adrian, T E; Bloom, S R

    1986-01-01

    Because somatostatin, a neuroregulatory peptide, is found in abundance in the atria and atrioventricular node, its electrophysiological and antiarrhythmic properties were compared with those of verapamil in ten patients with paroxysmal atrioventricular tachycardia. During sinus rhythm, intravenous somatostatin slowed the heart rate whereas verapamil increased it. Though both agents prolonged atrioventricular conduction time and refractoriness, verapamil was more potent. They were equally effective at terminating reentry atrioventricular tachycardia, restoring sinus rhythm in six of seven patients. Whereas verapamil consistently blocked conduction in the atrioventricular node, somatostatin usually induced ventricular extrasystoles at the time of conversion. Somatostatin may have physiological importance in the neurohumoral control of cardiac impulse formation and conduction. PMID:2875723

  7. Optimal programming management of ventricular tachycardia storm in ICD patients

    PubMed Central

    Qian, Zhiyong; Guo, Jianghong; Zhang, Zhiyong; Wang, Yao; Hou, Xiaofeng; Zou, Jiangang

    2015-01-01

    Abstract Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter defibrillator (ICD) therapy within 24 hours. Patients with VTS have poor outcomes and require immediate medical attention. ICD shocks have been shown to be associated with increased mortality in several studies. Optimal programming in minimization of ICD shocks may decrease mortality. Large controlled trials showed that long detection time and high heart rate detection threshold reduced ICD shock burden without an increase in syncope or death. As a fundamental therapy of ICD, antitachycardia pacing (ATP) can terminate most slow VT with a low risk of acceleration. For fast VT, burst pacing is more effective and less likely to result in acceleration than ramp pacing. One algorithm of optimal programming management during a VTS is presented in the review. PMID:25745473

  8. A narrow QRS tachycardia and cannon A waves: What is the mechanism?

    PubMed

    Ali, Hussam; Epicoco, Gianluca; De Ambroggi, Guido; Lupo, Pierpaolo; Foresti, Sara; Cappato, Riccardo

    2017-07-01

    Regular narrow QRS tachycardia, particularly if well-tolerated, is usually considered a "benign" arrhythmia of a supraventricular origin. This case concerns an 82-year-old male with ischemic heart disease who presented with recurrent episodes of a narrow QRS tachycardia that was initially diagnosed and treated as atrial tachyarrhythmia. However, careful physical examination and ECG analysis established the correct diagnosis, and the patient was managed appropriately. Remarkably, the observation of irregular cannon A waves, and Lewis lead recording, confirmed atrioventricular dissociation during tachycardia and indicated its underlying mechanism. © 2016 Wiley Periodicals, Inc.

  9. Intermittent atrial tachycardia promotes repolarization alternans and conduction slowing during rapid rates, and increases susceptibility to atrial fibrillation in a free-behaving sheep model.

    PubMed

    Monigatti-Tenkorang, Joanna; Jousset, Florian; Pascale, Patrizio; Vesin, Jean-Marc; Ruchat, Patrick; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne

    2014-04-01

    Paroxysmal atrial fibrillation (AF) may be triggered by intermittent atrial tachycardia, and ultimately lead to persistent AF. However, the mechanisms by which intermittent atrial tachycardia promotes sustained AF are not well understood. Eight sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms, and for the delivery of electrophysiological stimulation protocols and intermittent right atrial tachycardia. Right atrial kinetics of activation recovery interval (ARI) as a surrogate for action potential duration, of conduction time and velocity, and of repolarization alternans were analyzed at incremental pacing rates during the remodeling process induced by weeks of intermittent atrial tachycardia until the development of sustained AF. Intermittent atrial tachycardia decreased ARI and blunted its rate adaptation, facilitated atrial capture, and slowed conduction at high rates, and increased susceptibility to pacing-induced AF. In spite of blunted ARI rate adaptation, right atrial repolarization alternans was maintained during remodeling, and further increased in magnitude just before rapid pacing-induced AF. This study suggests that weeks of intermittent right atrial tachycardia result in a gradual electrical remodeling favorable for wavebreaks and reentry that may facilitate fibrillation. © 2014 Wiley Periodicals, Inc.

  10. The common Arg389gly ADRB1 polymorphism affects heart rate response to the ultra-short-acting β(1) adrenergic receptor antagonist esmolol in healthy individuals.

    PubMed

    Muszkat, Mordechai; Hoofien, Assaf; Orlanski-Meyer, Esther; Makhoul, Hani; Porat, Einav; Davidson, Eliad M; Blotnick, Simcha; Caraco, Yoseph

    2013-01-01

    The β1-adrenergic receptor (β1AR) Arg389Gly polymorphism affects responses to orally administered β1AR antagonists (β-blockers) in vivo. However, the effect of this polymorphism on the early heart rate response to β-blockers has not been evaluated. The aim of this study was to determine the effect of the Arg389Gly polymorphism on the inhibition of exercise-induced tachycardia by esmolol, an ultra-short-acting intravenously administered β1AR antagonist. Healthy nonsmoking White individuals were enrolled on the basis of their ADRB1 genotype, including carriers of 0, 1 or 2 Arg389 alleles (n=9 in each group, total 27, 18 men). Placebo and esmolol were infused consecutively for 10 min each, separated by 30 min. At the end of each infusion, participants performed dynamic handgrip exercise. Heart rate and blood pressure were compared among three ADRB1 genotypes. Carriers of 0, 1, or 2 Arg389 alleles varied significantly in both exercise-induced tachycardia during esmolol (P(ANOVA)=0.030) and esmolol inhibition of exercise-induced tachycardia [0.78±7.70, 5.11±4.05, 10.22±9.78 bpm, respectively (P=0.014)]. The early effect of esmolol on exercise-induced tachycardia was significantly greater among Arg389 than in Gly389 homozygote healthy individuals (NCT01388036). © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  11. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    PubMed

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  12. Heart rate is an independent predictor of all-cause mortality in individuals with type 2 diabetes: The diabetes heart study.

    PubMed

    Prasada, Sameer; Oswalt, Cameron; Yeboah, Phyllis; Saylor, Georgia; Bowden, Donald; Yeboah, Joseph

    2018-01-15

    To assess the association of resting heart rate with all-cause and cardiovascular disease (CVD) mortality in the Diabetes Heart Study (DHS). Out of a total of 1443 participants recruited into the DHS, 1315 participants with type 2 diabetes who were free of atrial fibrillation and supraventricular tachycardia during the baseline exam were included in this analysis. Heart rate was collected from baseline resting electrocardiogram and mortality (all-cause and CVD) was obtained from state and national death registry. Kaplan-Meier (K-M) and Cox proportional hazard analyses were used to assess the association. The mean age, body mass index (BMI) and systolic blood pressure (SBP) of the cohort were 61.4 ± 9.2 years, 32.0 ± 6.6 kg/m 2 , and 139.4 ± 19.4 mmHg respectively. Fifty-six percent were females, 85% were whites, 15% were blacks, 18% were smokers. The mean ± SD heart rate was 69.8 (11.9) beats per minute (bpm). After a median follow-up time of 8.5 years (maximum follow-up time is 14.0 years), 258 participants were deceased. In K-M analysis, participants with heart rate above the median had a significantly higher event rate compared with those below the median (log-rank P = 0.0223). A one standard deviation increase in heart rate was associated with all-cause mortality in unadjusted (hazard ratio 1.16, 95%CI: 1.03-1.31) and adjusted (hazard ratio 1.20, 95%CI: 1.05-1.37) models. Similar results were obtained with CVD mortality as the outcome of interest. Heart rate is an independent predictor of all-cause mortality in this population with type 2 diabetes. In this study, a 1-SD increase in heart rate was associated with a 20% increase in risk suggesting that additional prognostic information may be gleaned from this ubiquitously collected vital sign.

  13. Initial heart rate and cardiovascular outcomes in patients presenting with acute coronary syndrome.

    PubMed

    Asaad, Nidal; El-Menyar, Ayman; AlHabib, Khalid F; Shabana, Adel; Alsheikh-Ali, Alawi A; Almahmeed, Wael; Al Faleh, Hussam; Hersi, Ahmad; Al Saif, Shukri; Al-Motarreb, Ahmed; Sulaiman, Kadhim; Al Nemer, Khalid; Amin, Haitham; Al Suwaidi, Jassim

    2014-06-01

    To assess the impact of on-admission heart rate (HR) in patients presenting with acute coronary syndrome (ACS). Data were collected retrospectively from the second Gulf Registry of Acute Coronary Events. Patients were divided according to their initial HR into: (I: < 60, II: 60-69, III: 70-79, IV: 80-89 and V: ≥ 90 bpm). Patients' characteristics and hospital and one- and 12-month outcomes were analyzed and compared. Among 7939 consecutive ACS patients, groups I to V represented 7%, 13%, 20%, 23.5%, and 37%, respectively. Mean age was higher in groups I and V. Group V were more likely males, diabetic and hypertensive. ST-elevation myocardial infarction was the main presentation in groups I and V. Reperfusion therapies were less likely given to group V. Beta blockers were more frequently prescribed to group III in comparison to groups with higher HR. Groups I and V were associated with worse hospital outcomes. Multivariate analysis showed initial tachycardia as an independent predictor for heart failure (OR 2.2; 95%CI: 1.39-3.32), while bradycardia was independently associated with higher one-month mortality (OR 2.0; 95%CI: 1.04-3.85) CONCLUSION: The majority of ACS patients present with tachycardia. However, low or high HR is a marker of high risk that needs more attention and management.

  14. Tachycardia-bradycardia syndrome: Electrophysiological mechanisms and future therapeutic approaches (Review)

    PubMed Central

    Tse, Gary; Liu, Tong; Li, Ka Hou Christien; Laxton, Victoria; Wong, Andy On-Tik; Chan, Yin Wah Fiona; Keung, Wendy; Chan, Camie W.Y.; Li, Ronald A.

    2017-01-01

    Sick sinus syndrome (SSS) encompasses a group of disorders whereby the heart is unable to perform its pacemaker function, due to genetic and acquired causes. Tachycardia-bradycardia syndrome (TBS) is a complication of SSS characterized by alternating tachycardia and bradycardia. Techniques such as genetic screening and molecular diagnostics together with the use of pre-clinical models have elucidated the electrophysiological mechanisms of this condition. Dysfunction of ion channels responsible for initiation or conduction of cardiac action potentials may underlie both bradycardia and tachycardia; bradycardia can also increase the risk of tachycardia, and vice versa. The mainstay treatment option for SSS is pacemaker implantation, an effective approach, but has disadvantages such as infection, limited battery life, dislodgement of leads and catheters to be permanently implanted in situ. Alternatives to electronic pacemakers are gene-based bio-artificial sinoatrial node and cell-based bio-artificial pacemakers, which are promising techniques whose long-term safety and efficacy need to be established. The aim of this article is to review the different ion channels involved in TBS, examine the three-way relationship between ion channel dysfunction, tachycardia and bradycardia in TBS and to consider its current and future therapies. PMID:28204831

  15. Therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia and the risk factors for postoperative recurrence

    PubMed Central

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2018-01-01

    The present study investigated the therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia (SVT), and explored the risk factors for postoperative recurrence. A total of 312 patients with pediatric SVT were selected in the Affiliated Children's Hospital of Xuzhou Medical University from April, 2011 to March, 2017. All the patients were subjected to radiofrequency ablation, and clinical data were retrospectively analyzed. Tilt table test was performed before and after treatment, and heart rate, systolic and diastolic blood pressure before and after treatment were compared. Plasma levels of D-dimer (D-D), platelet α-granule membrane protein (GMP-140) and thrombin-antithrombin III complex (TAT) were detected by enzyme-linked immunosorbent assay before treatment, immediately after radiofrequency oblation, and at 1, 3 and 7 days after treatment. Treatment outcomes were compared between the atrioventricular reentrant tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) groups. Risk factors for postoperative recurrence were analyzed. Supine position heart rate after treatment was not significantly different from that before treatment (P>0.05), while the upright position heart rate was significantly increased after treatment (P<0.05). Systolic pressures of the supine and upright positions were significantly reduced after treatment compared with the levels before (P<0.05), but no significant differences were found in diastolic blood pressure of supine and the upright position (P>0.05). No significant difference in radiofrequency ablation rate, recurrence rate and incidence of complications were found between the AVRT and AVNRT groups (P>0.05). After radiofrequency, the levels of D-D, GMP-140 and TAT ablation showed an upward trend, but decreased at day 7 to reach preoperative levels. Logistic regression analysis revealed that residual slow pathway (OR=6.718, P=0.005) and inaccurate targeting (OR=2.815, P=0.007) were

  16. Therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia and the risk factors for postoperative recurrence.

    PubMed

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2018-05-01

    The present study investigated the therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia (SVT), and explored the risk factors for postoperative recurrence. A total of 312 patients with pediatric SVT were selected in the Affiliated Children's Hospital of Xuzhou Medical University from April, 2011 to March, 2017. All the patients were subjected to radiofrequency ablation, and clinical data were retrospectively analyzed. Tilt table test was performed before and after treatment, and heart rate, systolic and diastolic blood pressure before and after treatment were compared. Plasma levels of D-dimer (D-D), platelet α-granule membrane protein (GMP-140) and thrombin-antithrombin III complex (TAT) were detected by enzyme-linked immunosorbent assay before treatment, immediately after radiofrequency oblation, and at 1, 3 and 7 days after treatment. Treatment outcomes were compared between the atrioventricular reentrant tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) groups. Risk factors for postoperative recurrence were analyzed. Supine position heart rate after treatment was not significantly different from that before treatment (P>0.05), while the upright position heart rate was significantly increased after treatment (P<0.05). Systolic pressures of the supine and upright positions were significantly reduced after treatment compared with the levels before (P<0.05), but no significant differences were found in diastolic blood pressure of supine and the upright position (P>0.05). No significant difference in radiofrequency ablation rate, recurrence rate and incidence of complications were found between the AVRT and AVNRT groups (P>0.05). After radiofrequency, the levels of D-D, GMP-140 and TAT ablation showed an upward trend, but decreased at day 7 to reach preoperative levels. Logistic regression analysis revealed that residual slow pathway (OR=6.718, P=0.005) and inaccurate targeting (OR=2.815, P=0.007) were

  17. Orthostatic intolerance and the postural tachycardia syndrome: genetic and environment pathophysiologies. Neurolab Autonomic Team

    NASA Technical Reports Server (NTRS)

    Robertson, D.; Shannon, J. R.; Biaggioni, I.; Ertl, A. C.; Diedrich, A.; Carson, R.; Furlan, R.; Jacob, G.; Jordan, J.

    2000-01-01

    Orthostatic intolerance is a common problem for inbound space travelers. There is usually tachycardia on standing but blood pressure may be normal, low or, rarely, elevated. This condition is analogous to the orthostatic intolerance that occurs on Earth in individuals with orthostatic tachycardia, palpitations, mitral valve prolapse, and light-headedness. Our studies during the Neurolab mission indicated that sympathetic nerve traffic is raised in microgravity and that plasma norepinephrine is higher than baseline supine levels but lower than baseline upright levels. A subgroup of patients with familial orthostatic intolerance differ from inbound space travelers in that they have an alanine-to-to-proline mutation at amino acid position 457 in their norepinephrine transporter gene. This leads to poor clearance of norepinephrine from synapses, with consequent raised heart rate. Clinical features of these syndromes are presented.

  18. Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

    PubMed

    Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E

    2013-05-28

    The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p < 0.0001), with all-cause mortality (hazard ratio: 2.40; 95% confidence interval: 1.62 to 3.54; p < 0.0001), and with a composite of all-cause mortality and appropriate ICD shocks (hazard ratio: 3.03; 95% confidence interval: 2.21 to 4.15; p < 0.0001). RR-NSVT identified on routine ICD interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation

  19. Neonatal thyrotoxicosis with severe supraventricular tachycardia: case report and review of the literature.

    PubMed

    Abbasoğlu, Aslıhan; Ecevit, Ayşe; Tuğcu, Ali Ulaş; Erdoğan, Lkay; Kınık, Sibel Tulgar; Tarcan, Aylin

    2015-03-01

    Neonatal thyrotoxicosis is a rare condition caused by the transplacental passage of thyroid stimulating immunoglobulins from mothers with Graves' disease. We report a case of neonatal thyrotoxicosis with concurrent supraventricular tachycardia (SVT). The female infant, who was born by section due to breech delivery and meconium in the amniotic fluid at 36 weeks of gestation, presented with tachycardia on day 7. Her heart rate was between 260 and 300 beats/min, and an electrocardiogram revealed ongoing SVT. Sotalol was effective after two cardioversions in maintaining sinus rhythm. Thyroid function studies revealed hyperthyroidism in the infant, and her mother was found to have Graves' disease. Since symptoms and signs can vary, especially in preterm infants with neonatal hyperthyroidism, we want to emphasize the importance of prenatal care and follow-ups of Graves' disease associated pregnancies and management of newborns after birth.

  20. Re-entry using anatomically determined isthmuses: a curable ventricular tachycardia in repaired congenital heart disease.

    PubMed

    Kapel, Gijsbert F L; Reichlin, Tobias; Wijnmaalen, Adrianus P; Piers, Sebastiaan R D; Holman, Eduard R; Tedrow, Usha B; Schalij, Martin J; Stevenson, William G; Zeppenfeld, Katja

    2015-02-01

    Ventricular tachycardia (VT) is an important cause of late morbidity and mortality in repaired congenital heart disease. The substrate often includes anatomic isthmuses that can be transected by radiofrequency catheter ablation similar to isthmus block for atrial flutter. This study evaluates the long-term efficacy of isthmus block for treatment of re-entry VT in adults with repaired congenital heart disease. Thirty-four patients (49±13 years; 74% male) with repaired congenital heart disease who underwent radiofrequency catheter ablation of VT in 2 centers were included. Twenty-two (65%) had a preserved left and right ventricular function. Patients were inducible for 1 (interquartile range, 1-2) VT, median cycle length: 295 ms (interquartile range, 242-346). Ablation aimed to transect anatomic isthmuses containing VT re-entry circuit isthmuses. Procedural success was defined as noninducibility of any VT and transection of the anatomic isthmus and was achieved in 25 (74%) patients. During long-term follow-up (46±29 months), all patients with procedural success (18/25 with internal cardiac defibrillators) were free of VT recurrence but 7 of 18 experienced internal cardiac defibrillator-related complications. One patient with procedural success and depressed cardiac function received an internal cardiac defibrillator shock for ventricular fibrillation. None of the 18 patients (12/18 with internal cardiac defibrillators) with complete success and preserved cardiac function experienced any ventricular arrhythmia. In contrast, VT recurred in 4 of 9 patients without procedural success. Four patients died from nonarrhythmic causes. In patients with repaired congenital heart disease with preserved ventricular function and isthmus-dependent re-entry, VT isthmus ablation can be curative. © 2014 American Heart Association, Inc.

  1. Familial orthostatic tachycardia due to norepinephrine transporter deficiency

    NASA Technical Reports Server (NTRS)

    Robertson, D.; Flattem, N.; Tellioglu, T.; Carson, R.; Garland, E.; Shannon, J. R.; Jordan, J.; Jacob, G.; Blakely, R. D.; Biaggioni, I.

    2001-01-01

    Orthostatic intolerance (OI) or postural tachycardia syndrome (POTS) is a syndrome primarily affecting young females, and is characterized by lightheadedness, palpitations, fatigue, altered mentation, and syncope primarily occurring with upright posture and being relieved by lying down. There is typically tachycardia and raised plasma norepinephrine levels on upright posture, but little or no orthostatic hypotension. The pathophysiology of OI is believed to be very heterogeneous. Most studies of the syndrome have focused on abnormalities in norepinephrine release. Here the hypothesis that abnormal norepinephrine transporter (NET) function might contribute to the pathophysiology in some patients with OI was tested. In a proband with significant orthostatic symptoms and tachycardia, disproportionately elevated plasma norepinephrine with standing, impaired systemic, and local clearance of infused tritiated norepinephrine, impaired tyramine responsiveness, and a dissociation between stimulated plasma norepinephrine and DHPG elevation were found. Studies of NET gene structure in the proband revealed a coding mutation that converts a highly conserved transmembrane domain Ala residue to Pro. Analysis of the protein produced by the mutant cDNA in transfected cells demonstrated greater than 98% reduction in activity relative to normal. NE, DHPG/NE, and heart rate correlated with the mutant allele in this family. CONCLUSION: These results represent the first identification of a specific genetic defect in OI and the first disease linked to a coding alteration in a Na+/Cl(-)-dependent neurotransmitter transporter. Identification of this mechanism may facilitate our understanding of genetic causes of OI and lead to the development of more effective therapeutic modalities.

  2. Tachycardia in breast reconstructive microsurgery: Affirmation of the IMA tachycardia syndrome.

    PubMed

    Sachanandani, N S; Kale, S S; Skolnick, G B; Barbour, J R; Myckatyn, T M

    2015-06-01

    The internal mammary vessels are frequently chosen as recipient vessels for breast free flap reconstruction. We have noticed that when using the internal mammary recipients that these patients have a propensity for tachycardia that was not previously observed. Our aim was to investigate the factors related to perioperative tachycardia in the microsurgical breast reconstruction population and to address whether use of the internal mammary system is a causative factor in tachycardia. A retrospective chart review was conducted to identify patients who underwent abdominal-based microvascular breast reconstruction at the Washington University School of Medicine between 2002 and 2012 to identify the presence of tachycardia. After application of exclusion criteria, 76 microvascular abdominal-based free flap reconstructions were identified. The internal mammary (IM) TRAM group (n = 24) and the thoracodorsal (TD) TRAM group (n = 52) were compared. A binomial logistic regression was performed with the presence of tachycardia as the dependent variable. There was a higher incidence of tachycardia in the IM TRAM group when compared to the TD TRAM group (p = 0.004). The variables predictive of tachycardia in our logistic regression model were IMA recipient (p = 0.04), need for transfusion (p = 0.03), and presence of fever (p = 0.01). Our study reaffirms that there are several factors that are predictive of tachycardia in the setting of microvascular breast reconstruction. The IMA syndrome should be a recognized cause of tachycardia as using these recipient vessels are shown to be predictive of postoperative tachycardia as shown in our study. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Flecainide attenuates rate adaptation of ventricular repolarization in guinea-pig heart.

    PubMed

    Osadchii, Oleg E

    2016-01-01

    Flecainide is class Ic antiarrhythmic agent that was found to increase the risk of sudden cardiac death. Arrhythmic responses to flecainide could be precipitated by exercise, suggesting a role played by inappropriate rate adaptation of ventricular repolarization. This study therefore examined flecainide effect on adaptation of the QT interval and ventricular action potential duration (APD) to abrupt reductions of the cardiac cycle length. ECG and ventricular epicardial and endocardial monophasic APD were recorded in isolated, perfused guinea-pig heart preparations upon a sustained cardiac acceleration (rapid pacing for 30 s), and following a single perturbation of the cycle length evoked by extrasystolic stimulation. Sustained increase in heart rate was associated with progressive bi-exponential shortening of the QT interval and APD. Flecainide prolonged ventricular repolarization, delayed its rate adaptation, and decreased the amplitude of QT interval and APD shortening upon rapid cardiac pacing. During extrasystolic stimulation, flecainide attenuated APD shortening in premature ventricular beats, with effect being greater upon using a longer basic drive cycle length (S1-S1=550 ms versus S1-S1=300 ms). Flecainide-induced arrhythmia may be partly accounted for by attenuated adaptation of ventricular repolarization to sudden changes in cardiac cycle length provoked by transient tachycardia or ectopic beats.

  4. Experimental model of inappropriate sinus tachycardia: initiation and ablation.

    PubMed

    Scherlag, Benjamin J; Yamanashi, William S; Amin, Rohit; Lazzara, Ralph; Jackman, Warren M

    2005-06-01

    The purpose of the present study was to develop an experimental model of inappropriate sinus tachycardia (IST) by injecting a catecholamine into a fat pad containing autonomic ganglia (AG) innervating the sinus node (SN). Initial protocols in 3 groups of pentobarbital anesthetized dogs consisted of (1) slowing the heart rate (HR) by electrical stimulation of AG in the fat pad; (2) the effect of intravenous injection of epinephrine (0.1-0.3 mg) on the HR and systolic blood pressure (BP); (3) the response of SN rate to intravenously injected isoproterenol (1 microgm/kg). These studies established a reference for the response to epinephrine injection (mean dose 0.2 +/- 0.9 mg, n = 14) into the fat pad at the base of the right superior pulmonary vein (RSPV). ECG leads, right atrial and His bundle electrograms, BP and core body temperature were continuously monitored. Epinephrine, injected into the fat pad, caused a significant increase in heart rate (HR, average: 211 +/- 11/min, p < 0.05 compared to control) but little change in systolic BP, 149 +/- 10 mmHg, p = NS (Group I, N = 8). The tachycardia lasted >30 minutes. Ice mapping and P wave morphology showed the tachycardia origin in the SN in 6/8 and in the crista terminalis (CT) in 2. Injection of 0.4 cc of formaldehyde into the FP restored HR (159 +/- 16) toward baseline (154 +/- 18). In Group II (N = 6), the same regimen induced a significant increase in both HR and systolic BP (194 +/- 17/min and 230 +/- 24 mmHg, respectively) compared to control values (143 +/- 23/min, 162 +/- 24 mmHg) which lasted for > 30 minutes. Ice mapping and P wave morphology showed that the pacemaker was in the SN (1), overlying the CT (2), or atrioventricular junction (2). Formaldehyde (0.4 cc) injected into the FP restored both HR and systolic BP toward baseline values (148 +/- 29/min and 152 +/- 24 mmHg, p = NS) and prevented, slowing of the HR by electrical stimulation of the AG; moreover, the same dose of epinephrine injected

  5. A rabbit ventricular action potential model replicating cardiac dynamics at rapid heart rates.

    PubMed

    Mahajan, Aman; Shiferaw, Yohannes; Sato, Daisuke; Baher, Ali; Olcese, Riccardo; Xie, Lai-Hua; Yang, Ming-Jim; Chen, Peng-Sheng; Restrepo, Juan G; Karma, Alain; Garfinkel, Alan; Qu, Zhilin; Weiss, James N

    2008-01-15

    Mathematical modeling of the cardiac action potential has proven to be a powerful tool for illuminating various aspects of cardiac function, including cardiac arrhythmias. However, no currently available detailed action potential model accurately reproduces the dynamics of the cardiac action potential and intracellular calcium (Ca(i)) cycling at rapid heart rates relevant to ventricular tachycardia and fibrillation. The aim of this study was to develop such a model. Using an existing rabbit ventricular action potential model, we modified the L-type calcium (Ca) current (I(Ca,L)) and Ca(i) cycling formulations based on new experimental patch-clamp data obtained in isolated rabbit ventricular myocytes, using the perforated patch configuration at 35-37 degrees C. Incorporating a minimal seven-state Markovian model of I(Ca,L) that reproduced Ca- and voltage-dependent kinetics in combination with our previously published dynamic Ca(i) cycling model, the new model replicates experimentally observed action potential duration and Ca(i) transient alternans at rapid heart rates, and accurately reproduces experimental action potential duration restitution curves obtained by either dynamic or S1S2 pacing.

  6. Heart Rate Monitors

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Under a NASA grant, Dr. Robert M. Davis and Dr. William M. Portnoy came up with a new type of electrocardiographic electrode that would enable long term use on astronauts. Their invention was an insulated capacitive electrode constructed of a thin dielectric film. NASA subsequently licensed the electrode technology to Richard Charnitski, inventor of the VersaClimber, who founded Heart Rate, Inc., to further develop and manufacture personal heart monitors and to produce exercise machines using the technology for the physical fitness, medical and home markets. Same technology is on both the Home and Institutional Model VersaClimbers. On the Home Model an infrared heart beat transmitter is worn under exercise clothing. Transmitted heart rate is used to control the work intensity on the VersaClimber using the heart rate as the speedometer of the exercise. This offers advantages to a full range of users from the cardiac rehab patient to the high level physical conditioning of elite athletes. The company manufactures and markets five models of the 1*2*3 HEART RATE monitors that are used wherever people exercise to accurately monitor their heart rate. Company is developing a talking heart rate monitor that works with portable headset radios. A version of the heart beat transmitter will be available to the manufacturers of other aerobic exercise machines.

  7. Contribution of the autonomic nervous system to blood pressure and heart rate variability changes in early experimental hyperthyroidism.

    PubMed

    Safa-Tisseront, V; Ponchon, P; Laude, D; Elghozi, J L

    1998-07-10

    A great deal of uncertainty persists regarding the exact nature of the interaction between autonomic nervous system activity and thyroid hormones in the control of heart rate and blood pressure. We now report on thyrotoxicosis produced by daily intraperitoneal (i.p.) injection of L-thyroxine (0.5 mg/kg body wt. in 1 ml of 5 mM NaOH for 5 days). Control rats received i.p. daily injections of the thyroxine solvent. In order to estimate the degree of autonomic activation in hyperthyroidism, specific blockers were administered intravenously: atropine (0.5 mg/kg), prazosin (1 mg/kg), atenolol (1 mg/kg) or the combination of atenolol and atropine. A jet of air was administered in other animals to induce sympathoactivation. Eight animals were studied in each group. The dose and duration of L-thyroxine treatment was sufficient to induce a significant degree of hyperthyroidism with accompanying tachycardia, systolic blood pressure elevation, increased pulse pressure, cardiac hypertrophy, weight loss, tachypnea and hyperthermia. In addition, the intrinsic heart period observed after double blockade (atenolol + atropine) was markedly decreased after treatment with L-thyroxine (121.5+/-3.6 ms vs. 141.2+/-3.7 ms, P < 0.01). Of the autonomic indices, vagal tone (difference between heart period obtained after atenolol and intrinsic heart period) was negatively linearly related to intrinsic heart period (r = 0.71, P < 0.05). Atenolol modified neither the heart period nor blood pressure variability in rats with hyperthyroidism and in these rats the jet of air did not significantly affect the heart period level. The thyrotoxicosis was associated with a reduction of the 0.4 Hz component of blood pressure variability (analyses on 102.4 s segments, modulus 1.10+/-0.07 vs. 1.41+/-0.06 mm Hg, P < 0.01) and prazosin was without effect on this 0.4 Hz component in these animals. These data show a functional diminution of the vascular and cardiac sympathetic tone in early experimental

  8. Resolution of Postural Orthostatic Tachycardia Syndrome After CT-Guided, Percutaneous T2 Ethanol Ablation for Hyperhidrosis.

    PubMed

    Brock, Malcolm; Chung, Tae Hwan; Gaddam, Sathvika Reddy; Kathait, Anjaneya Singh; Ober, Cecily; Georgiades, Christos

    2016-12-01

    Postural orthostatic tachycardia syndrome is characterized by orthostatic intolerance. Orthostasis (or other mild physical stress) triggers a cascade of inappropriate tachycardia, lightheadedness, palpitations, and often fainting. The underlying defect is sympathetic dysregulation of the heart, which receives its sympathetic tone from the cervical and upper thoracic sympathetic ganglia. Primary hyperhidrosis is also thought to be the result of sympathetic dysregulation. We present the case of a patient treated with CT-guided, percutaneous T2 EtOH sympatholysis for craniofacial hyperhidrosis. The patient also suffered from postural orthostatic tachycardia syndrome for many years and was unresponsive to treatment. Immediately after sympatholysis, the patient experienced resolution of both craniofacial hyperhidrosis and postural orthostatic tachycardia syndrome.

  9. Resolution of Postural Orthostatic Tachycardia Syndrome After CT-Guided, Percutaneous T2 Ethanol Ablation for Hyperhidrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brock, Malcolm, E-mail: mabrock@jhmni.edu; Chung, Tae Hwan, E-mail: Tchang7@jhmi.edu; Gaddam, Sathvika Reddy, E-mail: drsathvikareddy@yahoo.com

    Postural orthostatic tachycardia syndrome is characterized by orthostatic intolerance. Orthostasis (or other mild physical stress) triggers a cascade of inappropriate tachycardia, lightheadedness, palpitations, and often fainting. The underlying defect is sympathetic dysregulation of the heart, which receives its sympathetic tone from the cervical and upper thoracic sympathetic ganglia. Primary hyperhidrosis is also thought to be the result of sympathetic dysregulation. We present the case of a patient treated with CT-guided, percutaneous T2 EtOH sympatholysis for craniofacial hyperhidrosis. The patient also suffered from postural orthostatic tachycardia syndrome for many years and was unresponsive to treatment. Immediately after sympatholysis, the patient experiencedmore » resolution of both craniofacial hyperhidrosis and postural orthostatic tachycardia syndrome.« less

  10. Tachycardia

    MedlinePlus

    ... normal while at rest. It's normal for your heart rate to rise during exercise or as a physiological ... the heart or both while at rest. Your heart rate is controlled by electrical signals sent across heart ...

  11. Tachycardia-bradycardia syndrome: Electrophysiological mechanisms and future therapeutic approaches (Review).

    PubMed

    Tse, Gary; Liu, Tong; Li, Ka Hou Christien; Laxton, Victoria; Wong, Andy On-Tik; Chan, Yin Wah Fiona; Keung, Wendy; Chan, Camie W Y; Li, Ronald A

    2017-03-01

    Sick sinus syndrome (SSS) encompasses a group of disorders whereby the heart is unable to perform its pacemaker function, due to genetic and acquired causes. Tachycardia‑bradycardia syndrome (TBS) is a complication of SSS characterized by alternating tachycardia and bradycardia. Techniques such as genetic screening and molecular diagnostics together with the use of pre-clinical models have elucidated the electrophysiological mechanisms of this condition. Dysfunction of ion channels responsible for initiation or conduction of cardiac action potentials may underlie both bradycardia and tachycardia; bradycardia can also increase the risk of tachycardia, and vice versa. The mainstay treatment option for SSS is pacemaker implantation, an effective approach, but has disadvantages such as infection, limited battery life, dislodgement of leads and catheters to be permanently implanted in situ. Alternatives to electronic pacemakers are gene‑based bio‑artificial sinoatrial node and cell‑based bio‑artificial pacemakers, which are promising techniques whose long-term safety and efficacy need to be established. The aim of this article is to review the different ion channels involved in TBS, examine the three‑way relationship between ion channel dysfunction, tachycardia and bradycardia in TBS and to consider its current and future therapies.

  12. A novel ECG detector performance metric and its relationship with missing and false heart rate limit alarms.

    PubMed

    Daluwatte, Chathuri; Vicente, Jose; Galeotti, Loriano; Johannesen, Lars; Strauss, David G; Scully, Christopher G

    Performance of ECG beat detectors is traditionally assessed on long intervals (e.g.: 30min), but only incorrect detections within a short interval (e.g.: 10s) may cause incorrect (i.e., missed+false) heart rate limit alarms (tachycardia and bradycardia). We propose a novel performance metric based on distribution of incorrect beat detection over a short interval and assess its relationship with incorrect heart rate limit alarm rates. Six ECG beat detectors were assessed using performance metrics over long interval (sensitivity and positive predictive value over 30min) and short interval (Area Under empirical cumulative distribution function (AUecdf) for short interval (i.e., 10s) sensitivity and positive predictive value) on two ECG databases. False heart rate limit and asystole alarm rates calculated using a third ECG database were then correlated (Spearman's rank correlation) with each calculated performance metric. False alarm rates correlated with sensitivity calculated on long interval (i.e., 30min) (ρ=-0.8 and p<0.05) and AUecdf for sensitivity (ρ=0.9 and p<0.05) in all assessed ECG databases. Sensitivity over 30min grouped the two detectors with lowest false alarm rates while AUecdf for sensitivity provided further information to identify the two beat detectors with highest false alarm rates as well, which was inseparable with sensitivity over 30min. Short interval performance metrics can provide insights on the potential of a beat detector to generate incorrect heart rate limit alarms. Published by Elsevier Inc.

  13. Thyroid Storm with Heart Failure Treated with a Short-acting Beta-adrenoreceptor Blocker, Landiolol Hydrochloride.

    PubMed

    Yamashita, Yugo; Iguchi, Moritake; Nakatani, Rieko; Usui, Takeshi; Takagi, Daisuke; Hamatani, Yasuhiro; Unoki, Takashi; Ishii, Mitsuru; Ogawa, Hisashi; Masunaga, Nobutoyo; Abe, Mitsuru; Akao, Masaharu

    2015-01-01

    Beta-adrenoreceptor blockers are essential in controlling the peripheral actions of thyroid hormones and a rapid heart rate in patients with thyroid storm, although they should be used with great caution when there is the potential for heart failure. A 67-year-old woman was diagnosed as having thyroid storm in addition to marked tachycardia with atrial fibrillation and heart failure associated with a reduced left ventricular function. The administration of an oral beta blocker, bisoprolol fumarate, induced hypotension and was not tolerable for the patient, whereas landiolol hydrochloride, a short-acting intravenous beta-adrenoreceptor blocker with high cardioselectivity and a short elimination half-life, was useful for controlling the patient's tachycardia and heart failure without causing hemodynamic deterioration.

  14. Heart rate turbulence.

    PubMed

    Cygankiewicz, Iwona

    2013-01-01

    Heart rate turbulence (HRT) is a baroreflex-mediated biphasic reaction of heart rate in response to premature ventricular beats. Heart rate turbulence is quantified by: turbulence onset (TO) reflecting the initial acceleration of heart rate following premature beat and turbulence slope (TS) describing subsequent deceleration of heart rate. Abnormal HRT identifies patients with autonomic dysfunction or impaired baroreflex sensitivity due to variety of disorders, but also may reflect changes in autonomic nervous system induced by different therapeutic modalities such as drugs, revascularization, or cardiac resynchronization therapy. More importantly, impaired HRT has been shown to identify patients at high risk of all-cause mortality and sudden death, particularly in postinfarction and congestive heart failure patients. It should be emphasized that abnormal HRT has a well-established role in stratification of postinfarction and heart failure patients with relatively preserved left ventricular ejection fraction. The ongoing clinical trials will document whether HRT can be used to guide implantation of cardioverter-defibrillators in this subset of patients, not covered yet by ICD guidelines. This review focuses on the current state-of-the-art knowledge regarding clinical significance of HRT in detection of autonomic dysfunction and regarding the prognostic significance of this parameter in predicting all-cause mortality and sudden death. © 2013.

  15. Impact of Standardizing Management of Atrial Fibrillation with Rapid Heart Rate in the Emergency Department

    PubMed Central

    de Leon, Ernesto; Duan, Lewei; Rippenberger, Ellen; Sharp, Adam L

    2018-01-01

    Context There is substantial variation in the emergency treatment of atrial fibrillation with tachycardia. A standardized treatment approach at an academic center decreased admissions without adverse outcomes, but this approach has not been evaluated in a community Emergency Department (ED). Objective To evaluate the implementation of a standardized treatment guideline for patients with atrial fibrillation and a rapid heart rate in a community ED. Design An observational pre-/postimplementation (August 2013 to July 2014 and August 2014 to July 2015, respectively) study at a community ED. The standardized treatment guideline encouraged early oral treatment with rate control medication, outpatient echocardiogram, and early follow-up. A multiple logistic regression model adjusting for patient characteristics was generated to investigate the association between the intervention and ED discharge rate. Main Outcome Measures The primary measure was ED discharge. Secondary measures included stroke or death, ED return visit, hospital readmission, length of stay, and use of oral rate control medications. Results A total of 199 (104 pre/95 post) ED encounters were evaluated. The ED discharge rate increased 14% after intervention (57.7% to 71.6%, p = 0.04), and use of rate control medications increased by 19.4% (p < 0.01). Adjusted multivariate results showed a nearly 2-fold likelihood of ED discharge after guideline implementation (odds ratio = 1.97, 95%confidence interval = 1.07–3.63). Length of stay, return visits, and hospital readmissionswere similar. Conclusion A standardized approach to ED patients with atrial fibrillation and tachycardia is associated with a decrease in hospital admissions without adversely affecting patient safety. PMID:29401054

  16. Heart-Rate and Breath-Rate Monitor

    NASA Technical Reports Server (NTRS)

    Cooper, T. G.

    1983-01-01

    Circuit requiring only four integrated circuits (IC's) measures both heart rate and breath rate. Phase-locked loops lock on heart-rate and respiration-rate input signals. Each loop IC contains two phase comparators. Positive-edge-triggered circuit used in making monitors insensitive to dutycycle variations.

  17. Postural orthostatic tachycardia syndrome: Dental treatment considerations.

    PubMed

    Brooks, John K; Francis, Laurie A P

    2006-04-01

    Postural orthostatic tachycardia syndrome (POTS) is a chronic, relatively common autonomic disorder typically affecting younger females. It is distinguished by a dramatic increase in heart rate on the assumption of an upright posture from the supine position. The authors provide an overview of the demographics, clinical assessment, diagnostic features, differential diagnoses, pathogeneses and medical treatment of patients with POTS, with an emphasis on the clinical treatment of the dental patient affected by the syndrome. Patients frequently exhibit symptoms of lightheadedness, fatigue, palpitations and syncope. Patients with POTS may have Ehlers-Danlos syndrome, mitral valve prolapse, chronic fatigue syndrome or, rarely, the Brugada syndrome. Despite widespread dissemination of information regarding POTS in the medical literature, scant information on it has appeared in dental publications. Dentists need to be familiar with the clinical features of POTS and be prepared to treat patients at risk of developing syncope.

  18. Fluoroless catheter ablation of various right and left sided supra-ventricular tachycardias in children and adolescents.

    PubMed

    Jan, Matevž; Žižek, David; Rupar, Katja; Mazić, Uroš; Kuhelj, Dimitrij; Lakič, Nikola; Geršak, Borut

    2016-11-01

    Electrophysiology study (EPS) and catheter ablation (CA) in children and adolescents carries a potentially harmful effect of radiation exposure when performed with the use of fluoroscopy. Our aim was to evaluate the feasibility, safety and effectiveness of fluoroless EPS and CA of various supra-ventricular tachycardias (SVTs) with the use of the 3D mapping system and intracardiac echocardiography (ICE). Forty-three consecutive children and adolescents (age 13 ± 3 years) underwent fluoroless EPS and CA for various supra-ventricular tachycardias. A three-dimensional (3D) mapping system NavX™ was used for guidance of diagnostic and ablation catheters in the heart. ICE was used as a fundamental imaging tool for transseptal punctures. Acute procedural success rate was 100 %. There were no procedure related complications and short-term follow up (10 ± 3 months) revealed 93 % arrhythmia free survival rate. Fluoroless CA of various SVTs in the paediatric population is feasible, safe and can be performed successfully with 3D mapping system and ICE.

  19. [Competitive sports and dilated cardiomyopathy: the case of a 32-year-old soccer player with ventricular tachycardia].

    PubMed

    Scharhag, J; Meyer, T; Görge, G; Kindermann, W

    2003-01-24

    A 32-year-old competitive soccer player presented with palpitations he had felt for 4 weeks during maximal activity (soccer training and match). The physical examination and an exercise electrocardiogram were carried out by his general practitioner up to 19 s at 350 W and a heart rate of 147/min without showing any abnormalities. All blood parameters revealed no signs of illness. During treadmill exercise at a heart rate of 181/min, a non-sustained ventricular tachycardia was induced. Echocardiography showed a dilated left ventricle with an enddiastolic diameter of 70 mm and low fractional shortening (28 %). Cardiac catheterization demonstrated a diminished left ventricular ejection fraction (38 %) and an enlarged enddiastolic volume (199 ml) without signs of coronary artery disease. Electrophysiologic testing induced a non-sustained ventricular tachycardia. The echocardiographic and angiographic results indicated a dilated cardiomyopathy. Competitive sports activities were stopped and treatment with a beta-blocker (metoprolol) and an ACE-antagonist (ramipril) was started. In young male and female athletes, the possibility of severe cardiac abnormalities have to be considered even in the presence of good physical fitness and performance. To reach a high sensitivity for diagnostic ergometry, the work-load must reach the maximal capacity of the cardio-pulmonary system. Differences in the exercise performance of athletes and untrained subjects have to be considered.

  20. BIOPHYSICAL CHARACTERISATION OF THE UNDER-APPRECIATED AND IMPORTANT RELATIONSHIP BETWEEN HEART RATE VARIABILITY AND HEART RATE

    PubMed Central

    Monfredi, Oliver; Lyashkov, Alexey E; Johnsen, Anne-Berit; Inada, Shin; Schneider, Heiko; Wang, Ruoxi; Nirmalan, Mahesh; Wisloff, Ulrik; Maltsev, Victor A; Lakatta, Edward G; Zhang, Henggui; Boyett, Mark R

    2014-01-01

    Heart rate variability (beat-to-beat changes in the RR interval) has attracted considerable attention over the last 30+ years (PubMed currently lists >17,000 publications). Clinically, a decrease in heart rate variability is correlated to higher morbidity and mortality in diverse conditions, from heart disease to foetal distress. It is usually attributed to fluctuation in cardiac autonomic nerve activity. We calculated heart rate variability parameters from a variety of cardiac preparations (including humans, living animals, Langendorff-perfused heart and single sinoatrial nodal cell) in diverse species, combining this with data from previously published papers. We show that regardless of conditions, there is a universal exponential decay-like relationship between heart rate variability and heart rate. Using two biophysical models, we develop a theory for this, and confirm that heart rate variability is primarily dependent on heart rate and cannot be used in any simple way to assess autonomic nerve activity to the heart. We suggest that the correlation between a change in heart rate variability and altered morbidity and mortality is substantially attributable to the concurrent change in heart rate. This calls for re-evaluation of the findings from many papers that have not adjusted properly or at all for heart rate differences when comparing heart rate variability in multiple circumstances. PMID:25225208

  1. [Postural tachycardia syndrome (PoTS): An up-to-date].

    PubMed

    Astudillo, L; Laure, A; Fabry, V; Pugnet, G; Maury, P; Labrunée, M; Sailler, L; Pavy-Le Traon, A

    2018-06-13

    Postural tachycardia syndrome (PoTS) is a multifactorial syndrome defined by an increase in heart rate ≥30bpm, within 10minutes of standing (or during a head up tilt test to at least 60°), in absence of orthostatic hypotension. It is associated with symptoms of cerebral hypoperfusion that are worse when upright and improve in supine position. Patients have an intense fatigue with a high incidence on quality of life. This syndrome can be explained by many pathophysiological mechanisms. It can be associated with Ehlers-Danlos disease and some autoimmune disorders. The treatment is based on nonpharmacological measures and treatment with propranolol, fludrocortisone or midodrine. Copyright © 2018 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier Masson SAS. All rights reserved.

  2. A key circulatory defence against asphyxia in infancy--the heart of the matter!

    PubMed

    Cohen, Gary; Katz-Salamon, Miriam; Malcolm, Girvan

    2012-12-01

    A resumption of, and escalation in, breathing efforts (hyperpnoea) reflexively accelerates heart rate (HR) and may facilitate cardiac and circulatory recovery from apnoea. We analysed whether this mechanism can produce a sustained rise in HR (tachycardia) when a sleeping infant is confronted by mild, rapidly worsening asphyxia, simulating apnoea. Twenty-seven healthy term-born infants aged 1-8 days rebreathed the expired gas for 90 s during quiet sleep to stimulate breathing and heart rate. To discriminate cardio-excitatory effects of central respiratory drive, lung inflation, hypoxia, hypercapnia and asphyxia, we varied the inspired O(2) level and compared temporal changes in response profiles as respiratory sensitivity to hypoxia and asphyxia 'reset' after birth. We demonstrate that asphyxia-induced hyperpnoea and tachycardia strengthen dramatically over the first week with different time courses and via separate mechanisms. Cardiac excitation by hypercapnia improves first, followed by a slower improvement in respiratory hypoxic drive. A rise in CO(2) consequently elicits stronger, longer lasting tachycardia than moderate increases in respiratory drive or lung expansion. We suggest that without a strong facilitating action of CO(2) on the immature heart, respiratory manoeuvres may be unable to reflexively counteract strong vagal bradycardia. This may increase the vulnerability of some infants to apnoea-asphyxia.

  3. Heart rate monitoring mobile applications

    PubMed Central

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone’s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ‘Unique Heart Rate Monitor’, you can also maintain your heart rate history for personal reflection and sharing with a provider. PMID:28293594

  4. Heart rate monitoring mobile applications.

    PubMed

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  5. [Surgical treatment of supraventricular tachycardia].

    PubMed

    Vigano, A N; Minzioni, G; Graffigna, A; Paganini, F; Salerno, J A

    1991-10-01

    The article deals with the modern approaches to the treatment of supraventricular tachycardia . The authors analyse the results of operations in ectopic atrial tachycardias, the Wolff-Parkinson-White syndrome, modal re-entry tachycardias, and atrial fibrillation . The last-named is of most interest because the authors possess experience in a new operation for isolation of the internodal tracts. In all conditions the authors obtained convincing evidence on the efficacy of modern surgical treatment in supraventricular tachycardias.

  6. Autoimmune Basis for Postural Tachycardia Syndrome

    ClinicalTrials.gov

    2018-01-23

    Postural Orthostatic Tachycardia Syndrome; Postural Tachycardia Syndrome; Tachycardia; Arrhythmias, Cardiac; Autonomic Nervous System Diseases; Orthostatic Intolerance; Cardiovascular Diseases; Primary Dysautonomias

  7. Implantable automatic scanning pacemaker for termination of supraventricular tachycardia.

    PubMed

    Spurrell, R A; Nathan, A W; Bexton, R S; Hellestrand, K J; Nappholz, T; Camm, A J

    1982-03-01

    Thirteen patients suffering from reentrant supraventricular tachycardia have undergone implantation of a scanning extrastimulus pacemaker. This pacemaker is fully implanted and automatic, and it requires no external control device to activate or control it. The pacemaker is activated when tachycardia occurs. After four cycles an extrastimulus is induced with a preset coupling time from a sensed intracardiac potential, and every four cycles thereafter a further extrastimulus occurs, but on each occasion there is a decrement in coupling cycle by 6 ms until 90 ms of the cardiac cycle has been scanned by extrastimuli. When necessary, two extrastimuli can be introduced with a fixed but preset coupling time between them. Every four beats two extrastimuli are induced but the coupling time between the spontaneous cardiac potential and the first stimulus is decreased by 6 ms until 90 ms of the cardiac cycle has been scanned. The coupling time between the two stimuli is fixed throughout the scan. When termination of tachycardia occurs the successful timing variables are retained in the pacemaker memory so that at the onset of the next episode of tachycardia these settings are used first. Pacemaker pulse width, sensitivity, tachycardia trigger rate, coupling intervals for both stimuli and the use of single or double extrastimuli are all programmable transcutaneously. Three patients required single, and seven patients double ventricular premature stimuli; three patients required double atrial premature stimuli for termination of tachycardia. Despite frequent attacks of tachycardia before implantation, only two patients had a sustained attack of tachycardia after pacemaker implantation.

  8. Electroanatomic Mapping-Guided Catheter Ablation of Supraventricular Tachycardia in Children with Ebstein's Anomaly.

    PubMed

    Ergul, Yakup; Koca, Serhat; Akdeniz, Celal; Tuzcu, Volkan

    2018-06-07

    In Ebstein's anomaly (EA), tachycardia substrates are complex, and accessory pathway (AP) ablations are often challenging. This study demonstrates the utility of the EnSite Velocity system (St. Jude Medical, St Paul, MN) in the catheter ablation of supraventricular tachycardia in children with EA. Twenty patients [Female/Male = 8/12, median age 11.5 years (2.6-18)] with EA who underwent catheter ablation guided by the EnSite Velocity system between December 2011 and December 2016 were retrospectively evaluated. Five patients had severe EA, and two of them were at Fontan palliation pathway. The most common indications for ablations were palpitations/syncope and treatment-resistant arrhythmias. Thirty-one tachycardia substrate foci (21 manifest AP, 2 concealed AP, 4 Mahaim AP, 3 focal atrial tachycardias, and 1 typical atrioventricular nodal reentrant tachycardia) were detected in 20 patients. There were multiple tachycardia substrates in 11 patients (55%). The patient-based acute procedure success rate was 19/20 (95%), and the tachycardia-based success rate was 30/31 (97%). The mean procedure time was 170 ± 43 min (90-265). Fluoroscopy was not used in 15 (75%) patients. The mean fluoroscopy time in the remaining five patients was 3.6 ± 2.9 min (0.7-7.8). During a mean follow-up of 35.1 ± 20.3 months (6-60), tachycardia recurred in four patients (4/19, 21%). No complications were seen. Catheter ablation of arrhythmias can be performed effectively and safely in pediatric EA patients by using a limited fluoroscopic approach with the help of electroanatomical mapping systems. However, the rate of tachycardia recurrence at follow-up remains high.

  9. Parenting Behaviors, Parent Heart Rate Variability, and Their Associations with Adolescent Heart Rate Variability.

    PubMed

    Graham, Rebecca A; Scott, Brandon G; Weems, Carl F

    2017-05-01

    Adolescence is a potentially important time in the development of emotion regulation and parenting behaviors may play a role. We examined associations among parenting behaviors, parent resting heart rate variability, adolescent resting heart rate variability and parenting behaviors as moderators of the association between parent and adolescent resting heart rate variability. Ninety-seven youth (11-17 years; 49.5 % female; 34 % African American, 37.1 % Euro-American, 22.6 % other/mixed ethnic background, and 7.2 % Hispanic) and their parents (n = 81) completed a physiological assessment and questionnaires assessing parenting behaviors. Inconsistent discipline and corporal punishment were negatively associated with adolescent resting heart rate variability, while positive parenting and parental involvement were positively associated. Inconsistent discipline and parental involvement moderated the relationship between parent and adolescent resting heart rate variability. The findings provide evidence for a role of parenting behaviors in shaping the development of adolescent resting heart rate variability with inconsistent discipline and parental involvement potentially influencing the entrainment of resting heart rate variability in parents and their children.

  10. A key circulatory defence against asphyxia in infancy – the heart of the matter!

    PubMed Central

    Cohen, Gary; Katz-Salamon, Miriam; Malcolm, Girvan

    2012-01-01

    A resumption of, and escalation in, breathing efforts (hyperpnoea) reflexively accelerates heart rate (HR) and may facilitate cardiac and circulatory recovery from apnoea. We analysed whether this mechanism can produce a sustained rise in HR (tachycardia) when a sleeping infant is confronted by mild, rapidly worsening asphyxia, simulating apnoea. Twenty-seven healthy term-born infants aged 1–8 days rebreathed the expired gas for 90 s during quiet sleep to stimulate breathing and heart rate. To discriminate cardio-excitatory effects of central respiratory drive, lung inflation, hypoxia, hypercapnia and asphyxia, we varied the inspired O2 level and compared temporal changes in response profiles as respiratory sensitivity to hypoxia and asphyxia ‘reset’ after birth. We demonstrate that asphyxia-induced hyperpnoea and tachycardia strengthen dramatically over the first week with different time courses and via separate mechanisms. Cardiac excitation by hypercapnia improves first, followed by a slower improvement in respiratory hypoxic drive. A rise in CO2 consequently elicits stronger, longer lasting tachycardia than moderate increases in respiratory drive or lung expansion. We suggest that without a strong facilitating action of CO2 on the immature heart, respiratory manoeuvres may be unable to reflexively counteract strong vagal bradycardia. This may increase the vulnerability of some infants to apnoea – asphyxia. PMID:23006482

  11. Does atrioventricular reentry tachycardia (AVRT) or atrioventricular nodal reentry tachycardia (AVNRT) in children affect their cognitive and emotional development?

    PubMed

    Maryniak, Agnieszka; Bielawska, Alicja; Bieganowska, Katarzyna; Miszczak-Knecht, Maria; Walczak, Franciszek; Szumowski, Lukasz

    2013-04-01

    The current study sought to assess cognitive and emotional functions among children and adolescents with atrioventricular reentry tachycardia (AVRT) and atrioventricular nodal reentry tachycardia (AVNRT). 113 patients (62 girls and 51 boys ages, 9-18 years) scheduled for radiofrequency ablation due to AVRT or AVNRT underwent neuropsychologic examination. The study excluded patients who had experienced cardiac arrest, congenital heart defects, neurologic disorders, or other diseases affecting cognitive or emotional development. Standardized tests for examining verbal and visual memory as well as visual-spatial functioning were performed. For patients exhibiting deficits in two or more tests, a diagnosis of "cognitive deficits" was determined. Levels of anxiety were tested using the State-Trait Anxiety Inventory. Cognitive deficits were found in 47.8 % of the patients. The age at first arrhythmia attack was related to memory dysfunction. The mean age at which the first symptoms occurred was significantly lower for patients with deficits (8.3 years) than for patients who had no deficit (10.2 years) (t = 2.15; p = 0.03). Boys exhibited a significantly higher level of trait anxiety than girls (t = 3.42; p = 0.0009). A significant negative correlation was found between anxiety and the age at appearance of the first symptoms (r = -0.26; p = 0.005). These findings led us to conclude that cognitive and emotional developments can be negatively affected by AVNRT and AVRT, particularly if tachycardia appears early in life.

  12. Temporal and quantitative associations of electronic fetal heart rate monitoring patterns and neonatal outcomes†.

    PubMed

    Ogunyemi, Dotun; Jovanovski, Andrew; Friedman, Perry; Sweatman, Brittany; Madan, Ichchha

    2018-04-06

    The objective of this study is to evaluate the associations of electronic fetal heart rate monitoring (EFM) patterns and adverse neonatal outcomes Study design: From 2013 to 2016; 12,067 term, singleton deliveries in labor ≥2 h with abnormal EFM defined as absent accelerations, variable, late or prolonged decelerations, tachycardia, bradycardia, or minimal variability were analyzed as any documentation during labor, in first hour and last hour of labor. Outcomes were composite neonatal adverse outcomes, neonatal intensive care unit (NICU) admission, neonatal hypoxia, neonatal hypoglycemia, umbilical artery pH, and base excess. Independent associations were ascertained using regression analysis. Significant independent associations occurred between any abnormal EFM during the last hour and five adverse neonatal outcomes; between abnormal EFM at any time and one adverse neonatal outcome while there was none with the first hour of labor. In the last hour, accelerations had significant negative associations with three adverse neonatal outcomes, while prolonged decelerations, late decelerations, tachycardia, and bradycardia had significant positive associations with three adverse neonatal outcomes. Throughout labor, increasing accelerations events were significantly negatively correlated with all adverse neonatal outcomes, while increasing frequency of late, variable, and prolonged decelerations were positively associated with five adverse neonatal outcomes. Hierarchical analysis showed that bradycardia/tachycardia contributed only 0.8%, while all EFM periodic changes contributed 1%; the addition of the frequencies of abnormal EFM events contributed 0.6% to the variance in umbilical artery pH and base excess. Terminal EFM patterns are independently associated with neonatal outcomes. Accelerations are protective of adverse neonatal outcomes. Increasing frequency of EFM patterns overtime contributes to neonatal outcome.

  13. Impact of tachycardia and sympathetic stimulation by cold pressor test on cardiac diastology and arterial function in elderly females.

    PubMed

    Johnson, Jonas; Håkansson, Felicia; Shahgaldi, Kambiz; Manouras, Aristomenis; Norman, Mikael; Sahlén, Anders

    2013-04-01

    Abnormal vascular-ventricular coupling has been suggested to contribute to heart failure with preserved ejection fraction in elderly females. Failure to increase stroke volume (SV) during exercise occurs in parallel with dynamic changes in arterial physiology leading to increased afterload. Such adverse vascular reactivity during stress may reflect either sympathoexcitation or be due to tachycardia. We hypothesized that afterload elevation induces SV failure by transiently attenuating left ventricular relaxation, a phenomenon described in animal research. The respective roles of tachycardia and sympathoexcitation were investigated in n = 28 elderly females (70 ± 4 yr) carrying permanent pacemakers. At rest, during atrial tachycardia pacing (ATP; 100 min(-1)) and during cold pressor test (hand immersed in ice water), we performed Doppler echocardiography (maximal untwist rate analyzed by speckle tracking imaging of rotational mechanics) and arterial tonometry (arterial stiffness estimated as augmentation index). Estimation of arterial compliance was based on an exponential relationship between arterial pressure and volume. We found that ATP produced central hypovolemia and a reduction in SV which was larger in patients with stiffer arteries (higher augmentation index). There was an associated adverse response of arterial compliance and vascular resistance during ATP and cold pressor test, causing an overall increase in afterload, but nonetheless enhanced maximal rate of untwist and no evidence of afterload-dependent failure of relaxation. In conclusion, tachycardia and cold provocation in elderly females produces greater vascular reactivity and SV failure in the presence of arterial stiffening, but SV failure does not arise secondary to afterload-dependent attenuation of relaxation.

  14. Association between heart rate variability and manual pulse rate.

    PubMed

    Hart, John

    2013-09-01

    One model for neurological assessment in chiropractic pertains to autonomic variability, tested commonly with heart rate variability (HRV). Since HRV may not be convenient to use on all patient visits, more user-friendly methods may help fill-in the gaps. Accordingly, this study tests the association between manual pulse rate and heart rate variability. The manual rates were also compared to the heart rate derived from HRV. Forty-eight chiropractic students were examined with heart rate variability (SDNN and mean heart rate) and two manual radial pulse rate measurements. Inclusion criteria consisted of participants being chiropractic students. Exclusion criteria for 46 of the participants consisted of a body mass index being greater than 30, age greater than 35, and history of: a) dizziness upon standing, b) treatment of psychiatric disorders, and c) diabetes. No exclusion criteria were applied to the remaining two participants who were also convenience sample volunteers. Linear associations between the manual pulse rate methods and the two heart rate variability measures (SDNN and mean heart) were tested with Pearson's correlation and simple linear regression. Moderate strength inverse (expected) correlations were observed between both manual pulse rate methods and SDNN (r = -0.640, 95% CI -0.781, -0.435; r = -0.632, 95% CI -0.776, -0.425). Strong direct (expected) relationships were observed between the manual pulse rate methods and heart rate derived from HRV technology (r = 0.934, 95% CI 0.885, 0.962; r = 0.941, 95% CI 0.897, 0.966). Manual pulse rates may be a useful option for assessing autonomic variability. Furthermore, this study showed a strong relationship between manual pulse rates and heart rate derived from HRV technology.

  15. Postural tachycardia syndrome: time frequency mapping

    NASA Technical Reports Server (NTRS)

    Novak, V.; Novak, P.; Opfer-Gehrking, T. L.; Low, P. A.

    1996-01-01

    Orthostatic tachycardia is common but its specificity remains uncertain. Our preliminary work suggested that using autonomic function testing in conjunction with time-frequency mapping (TFM), it might be possible to characterize a subset of the postural tachycardia syndrome (POTS), that is due to a restricted autonomic neuropathy. We describe 20 patients (17 women and 3 men, aged 14-43 years) with florid POTS and 20 controls (14 women and 6 men, aged 20-41 years). Autonomic failure was quantified by its distribution (cardiovagal, adrenergic and sudomotor) and severity, a symptom profile was generated, and spectral indices, based on modified Wigner distribution during rest and head-up tilt (80 degrees) were evaluated. During tilt-up POTS patients differed from controls by an excessive heart rate (> 130 bpm) (P < 0.001), and higher diastolic pressure (P < 0.01). During rest, cardiovagal oscillations (at respiratory frequencies [RF]) and slow rhythms at nonrespiratory frequencies (NONRF) (from 0.01 to 0.07 Hz) in R-R intervals (RRI) (P < 0.01) were reduced. Both RF and NONRF rhythms in RRI were further blunted with tilt-up (P < 0.001). Slow adrenergic vasomotor rhythms in blood pressure (BP) (approximately 0.07 Hz) surged with tilt-up and returned to normal levels afterwards. The index of sympatho-vagal balance (NONRF-Systolic BP (SBP)/RF-RRI) was dramatically increased in POTS (P < 0.001). Distal postganglionic sudomotor failure was observed, and impairment of the BP responses to the Valsalva maneuver (phase II) suggested peripheral adrenergic dysfunction. Persistent orthostatic dizziness, tiredness, gastrointestinal symptoms and palpitations were common in POTS patients. It is possible to identify a subset of POTS patients who have a length-dependent autonomic neuropathy, affecting the peripheral adrenergic and cardiovagal fibers, with relative preservation of cardiac adrenergic fibers.

  16. Mice lacking melanin-concentrating hormone receptor 1 demonstrate increased heart rate associated with altered autonomic activity.

    PubMed

    Astrand, Annika; Bohlooly-Y, Mohammad; Larsdotter, Sara; Mahlapuu, Margit; Andersén, Harriet; Tornell, Jan; Ohlsson, Claes; Snaith, Mike; Morgan, David G A

    2004-10-01

    Melanin-concentrating hormone (MCH) plays an important role in energy balance. The current studies were carried out on a new line of mice lacking the rodent MCH receptor (MCHR1(-/-) mice). These mice confirmed the previously reported lean phenotype characterized by increased energy expenditure and modestly increased caloric intake. Because MCH is expressed in the lateral hypothalamic area, which also has an important role in the regulation of the autonomic nervous system, heart rate and blood pressure were measured by a telemetric method to investigate whether the increased energy expenditure in these mice might be due to altered autonomic nervous system activity. Male MCHR1(-/-) mice demonstrated a significantly increased heart rate [24-h period: wild type 495 +/- 4 vs. MCHR1(-/-) 561 +/- 8 beats/min (P < 0.001); dark phase: wild type 506 +/- 8 vs. MCHR1(-/-) 582 +/- 9 beats/min (P < 0.001); light phase: wild type 484 +/- 13 vs. MCHR1(-/-) 539 +/- 9 beats/min (P < 0.005)] with no significant difference in mean arterial pressure [wild type 110 +/- 0.3 vs. MCHR1(-/-) 113 +/- 0.4 mmHg (P > 0.05)]. Locomotor activity and core body temperature were higher in the MCHR1(-/-) mice during the dark phase only and thus temporally dissociated from heart rate differences. On fasting, wild-type animals rapidly downregulated body temperature and heart rate. MCHR1(-/-) mice displayed a distinct delay in the onset of this downregulation. To investigate the mechanism underlying these differences, autonomic blockade experiments were carried out. Administration of the adrenergic antagonist metoprolol completely reversed the tachycardia seen in MCHR1(-/-) mice, suggesting an increased sympathetic tone.

  17. Wide QRS tachycardia: what is the rhythm?

    PubMed

    Rosman, Jonathan; Tawil, Joseph; Hanon, Sam; Schweitzer, Paul

    2006-10-01

    We report a case of an elderly man who presented to the emergency room complaining of palpitations. Electrocardiogram revealed wide QRS tachycardia with a narrow beat within the tachycardia. Most commonly, a narrow complex beat during a wide complex tachycardia suggests a capture or fusion beat in the setting of ventricular tachycardia. However, there are situations where supraventricular tachycardia can also manifest this way. In our patient a pacemaker interrogation clarified the diagnosis.

  18. Management of ventricular tachycardia in the ablation era: results of the European Heart Rhythm Association Survey.

    PubMed

    Tilz, Roland Richard; Lenarczyk, Radoslaw; Scherr, Daniel; Haugaa, Kristina Herman; Iliodromitis, Konstantinos; Pürerfellner, Helmut; Kiliszek, Marek; Dagres, Nikolaos

    2018-01-01

    Patients with sustained ventricular tachycardia (VT) are at risk of sudden death. Treatment options for VT include antiarrhythmic drug therapy, insertion of an implantable cardioverter-defibrillator, and catheter ablation. Evidence on indications for VT ablation, timing, ablation strategies, and periprocedural management is sparse. The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding management of VT among the European countries. An electronic questionnaire was sent to members of the EHRA Electrophysiology Research Network. Responses were received from 88 centres in 12 countries. The results have shown that management of VTs is very heterogeneous across the participating centres. Indications, periprocedural management, and ablation strategies vary substantially. This EP Wire survey has revealed that catheter ablation is the first-line therapy for the treatment of recurrent monomorphic stable VT in patients without structural heart disease as well as in patients with ischaemic cardiomyopathy and impaired left ventricular ejection fraction in the majority of centres. Furthermore, in patients with ischaemic cardiomyopathy and the first episode of monomorphic VT, most centres (62.0%) performed catheter ablation. On the contrary, in patients with non-ischaemic cardiomyopathy, amiodarone (41.4%) and catheter ablation (37.1%) are used in a very similar proportion. Ablation strategies, endpoints, and post-ablation antithrombotic management vary substantially among European centres. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  19. Paroxysmal supraventricular tachycardia in an octogenarian.

    PubMed

    Lutwak, Nancy; Dill, Curt

    2012-09-01

    Paroxysmal supraventricular tachycardia is a common dysrhythmia that occurs at all ages. Its management is determined by presenting symptoms and previous history of the patient. Patients present with a continuum of symptoms ranging from palpitations to syncope. The incidence of supraventricular tachycardia increases with age. To discuss the etiology, precipitating factors, and acute management of supraventricular tachycardia; and to discuss nodal reentry circuits and representative electrocardiographic findings. We present the case of an 84-year-old man with gallstone pancreatitis, choledolcholithiasis, and cholecystitis complicated by paroxysmal supraventricular tachycardia. We review this dysrhythmia, emphasizing its significance in elderly patients. Supraventricular tachycardia is a common dysrhythmia that can result in syncope or myocardial infarction. We present a case of an elderly man with new-onset atrioventricular (AV) nodal reentry tachycardia, possibly precipitated by overdrive of his autonomic nervous system due to pain and infection. As the percentage of the elderly in our population is growing rapidly and the incidence of AV nodal reentry tachycardia increases with age, emergency physicians should be familiar with this dysrhythmia-its etiology, precipitating factors, presentations, and treatment. It will present more frequently in the future. Published by Elsevier Inc.

  20. Blood Pressure vs. Heart Rate

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 Understanding the difference ... your blood moving through your blood vessels, your heart rate is the number of times your heart beats ...

  1. Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy.

    PubMed

    Ponikowski, P; Anker, S D; Chua, T P; Szelemej, R; Piepoli, M; Adamopoulos, S; Webb-Peploe, K; Harrington, D; Banasiak, W; Wrabec, K; Coats, A J

    1997-06-15

    After acute myocardial infarction, depressed heart rate variability (HRV) has been proven to be a powerful independent predictor of a poor outcome. Although patients with chronic congestive heart failure (CHF) have also markedly impaired HRV, the prognostic value of HRV analysis in these patients remains unknown. The aim of this study was to investigate whether HRV parameters could predict survival in 102 consecutive patients with moderate to severe CHF (90 men, mean age 58 years, New York Heart Association [NYHA] class II to IV, CHF due to idiopathic dilated cardiomyopathy in 24 patients and ischemic heart disease in 78 patients, ejection fraction [EF], 26%; peak oxygen consumption, 16.9 ml/kg/min) after exclusion of patients in atrial fibrilation with diabetes or with chronic renal failure. In the prognostic analysis (Cox proportional-hazards model, Kaplan-Meier survival analysis), the following factors were investigated: age, CHF etiology, NYHA class, EF, peak oxygen consumption, presence of ventricular tachycardia on Holter monitoring, and HRV measures derived from 24-hour electrocardiography monitoring, calculated in the time (standard deviation of all normal RR intervals [SDNN], standard deviation of 5-minute RR intervals [SDANN], mean of all 5-minute standard deviations of RR intervals [SD], root-mean-square of difference of successive RR intervals [rMSSD], and percentage of adjacent RR intervals >50 ms different [pNN50]) and frequency domain (total power [TP], power within low-frequency band [LF], and power within high-frequency band [HF]). During follow-up of 584 +/- 405 days (365 days in all who survived), 19 patients (19%) died (mean time to death: 307 +/- 315 days, range 3 to 989). Cox's univariate analysis identified the following factors to be predictors of death: NYHA (p = 0.003), peak oxygen consumption (p = 0.01), EF (p = 0.02), ventricular tachycardia on Holter monitoring (p = 0.05), and among HRV measures: SDNN (p = 0.004), SDANN (p = 0.003), SD

  2. Outcome of Radiofrequency Catheter Ablation as a non-pharmacological therapy for idiopathic Ventricular Tachycardia.

    PubMed

    Samore, Naseer Ahmed; Imran Majeed, Syed Muhammad; Kayani, Azhar Mahmud; Bhalli, Muhammad Asif; Shabbir, Muhammad

    2009-09-01

    To determine the outcome of Radiofrequency Catheter Ablation (RFCA) as a non-pharmacological curative therapy for idiopathic Ventricular Tachycardia (VT) and to identify procedure-related complications. Descriptive study. The Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from February 2001 to October 2008. Ninety eight consecutive patients with idiopathic VT, resistant to drug therapy, who underwent Electrophysiology Studies (EPS) radiofrequency catheter ablation were enrolled. Clinical and electrophysiological variables were recorded and a descriptive analysis was done. Out of the 98 patients, 79 were males (80.6%). The mean age was 33.29+11.93 years. Modes of presentation were sustained VT, Repetitive Monomorphic VT (RMVT), Non-sustained VT (NSVT) and Ventricular Premature Beats (VPBs). Right Ventricular Outflow Tract (RVOT) VT was found in 37 patients, 37 had Idiopathic Left Ventricular Tachycardia (ILVT), 20 had Left Ventricular Outflow Tract (LVOT) VT, and Inflow Right Ventricular Tachycardia (IRVT) was found in 7 patients. Other sites of origin of VT were infrequent. Eight patients had dual morphologies of VT. Atrioventricular Nodal Re-entry Tachycardia (AVNRT) was found in 8 patients. RFCA was successful in abolishing inducible VT in 88 patients. One patient developed complete AV block requiring a permanent pacemaker. Results of this study confirm a high degree of success and safety of radiofrequency catheter ablation as curative therapy for idiopathic ventricular tachycardia.

  3. Heart Rate Monitor

    NASA Technical Reports Server (NTRS)

    1984-01-01

    In the mid 70's, NASA saw a need for a long term electrocardiographic electrode suitable for use on astronauts. Heart Rate Inc.'s insulated capacitive electrode is constructed of thin dielectric film applied to stainless steel surface, originally developed under a grant by Texas Technical University. HRI, Inc. was awarded NASA license and continued development of heart rate monitor for use on exercise machines for physical fitness and medical markets.

  4. Management of supraventricular arrhythmias in adults with congenital heart disease.

    PubMed

    Wasmer, Kristina; Eckardt, Lars

    2016-10-15

    Supraventricular arrhythmias are a frequent complication in adults with congenital heart disease (ACHD). The prevalence increases with time since surgery, complexity of the underlying defect, type of repair and older age at surgery. Arrhythmias are the most frequent reason for hospital admission and along with heart failure the leading cause of death. The arrhythmia-associated increase in morbidity and mortality makes their management a key task in patients with ACHD. Intra-atrial re-entry is the most frequent arrhythmia mechanism. Less common arrhythmia mechanisms are supraventricular tachycardias in the presence of an accessory pathway, atrioventricular nodal re-entrant tachycardia or focal tachycardias. Patient management includes stroke prevention, acute termination and prevention of arrhythmia recurrence. Acute treatment depends on patients' symptoms. In cases of haemodynamic instability, immediate cardioversion is warranted. For stable patients, acute treatment includes rate control and termination by antiarrhythmic drugs or electrical cardioversion. Following a symptomatic arrhythmia, catheter ablation or treatment with antiarrhythmic drugs is recommended to prevent recurrences. Advances in mapping and ablation technology are now associated with high success rates of catheter ablation. In patients with a complex substrate recurrence rates of 50% remain high. However, in the presence of side effects and complications associated with long-term antiarrhythmic drug therapy, redo procedures are encouraged by current guidelines. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Autonomic control of post-air-breathing tachycardia in Clarias gariepinus (Teleostei: Clariidae).

    PubMed

    Teixeira, Mariana Teodoro; Armelin, Vinicius Araújo; Abe, Augusto Shinya; Rantin, Francisco Tadeu; Florindo, Luiz Henrique

    2015-08-01

    The African catfish (Clarias gariepinus) is a teleost with bimodal respiration that utilizes a paired suprabranchial chamber located in the gill cavity as an air-breathing organ. Like all air-breathing fishes studied to date, the African catfish exhibits pronounced changes in heart rate (f H) that are associated with air-breathing events. We acquired f H, gill-breathing frequency (f G) and air-breathing frequency (f AB) in situations that require or do not require air breathing (during normoxia and hypoxia), and we assessed the autonomic control of post-air-breathing tachycardia using an infusion of the β-adrenergic antagonist propranolol and the muscarinic cholinergic antagonist atropine. During normoxia, C. gariepinus presented low f AB (1.85 ± 0.73 AB h(-1)) and a constant f G (43.16 ± 1.74 breaths min(-1)). During non-critical hypoxia (PO2 = 60 mmHg), f AB in the African catfish increased to 5.42 ± 1.19 AB h(-1) and f G decreased to 39.12 ± 1.58 breaths min(-1). During critical hypoxia (PO2 = 20 mmHg), f AB increased to 7.4 ± 1.39 AB h(-1) and f G decreased to 34.97 ± 1.78 breaths min(-1). These results were expected for a facultative air breather. Each air breath (AB) was followed by a brief but significant tachycardia, which in the critical hypoxia trials, reached a maximum of 143 % of the pre-AB f H values of untreated animals. Pharmacological blockade allowed the calculation of cardiac autonomic tones, which showed that post-AB tachycardia is predominantly regulated by the parasympathetic subdivision of the autonomic nervous system.

  6. Prospective Observational Cohort Study of Fetal Atrial Flutter & Supraventricular Tachycardia

    ClinicalTrials.gov

    2017-12-15

    Atrial Flutter; Tachycardia, Supraventricular; Tachycardia, Atrial Ectopic; Tachycardia, Reciprocating; Tachycardia Atrial; Tachycardia, Atrioventricular Nodal Reentry; Tachycardia, Paroxysmal; Fetal Hydrops

  7. Lessons from the Heart: Individualizing Physical Education with Heart Rate Monitors.

    ERIC Educational Resources Information Center

    Kirkpatrick, Beth; Birnbaum, Burton H.

    Learning about the relationship between heart rate and physical activity is an important aspect of fitness education. Use of a heart rate monitor (HRM) helps a student to understand how stretching and large muscle movements gradually increase the heart rate and blood flow, and enables students to measure their exercise heart rates and set goals…

  8. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  9. Heart rate changes during electroconvulsive therapy

    PubMed Central

    2013-01-01

    Background This observational study documented heart rate over the entire course of electrically induced seizures and aimed to evaluate the effects of stimulus electrode placement, patients' age, stimulus dose, and additional predictors. Method In 119 consecutive patients with 64 right unilateral (RUL) and 55 bifrontal (BF) electroconvulsive treatments, heart rate graphs based on beat-to-beat measurements were plotted up to durations of 130 s. Results In RUL stimulation, the initial drop in heart rate lasted for 12.5 ± 2.6 s (mean ± standard deviation). This depended on stimulus train duration, age, and baseline heart rate. In seizures induced with BF electrode placement, a sympathetic response was observed within the first few seconds of the stimulation phase (median 3.5 s). This was also the case with subconvulsive stimulations. The mean peak heart rate in all 119 treatments amounted to 135 ± 20 bpm and depended on baseline heart rate and seizure duration; electrode placement, charge dose, and age were insignificant in regression analysis. A marked decline in heart rate in connection with seizure cessation occurred in 71% of treatments. Conclusions A significant independent effect of stimulus electrode positioning on cardiac action was evident only in the initial phase of the seizures. Electrical stimulation rather than the seizure causes the initial heart rate increase in BF treatments. The data reveal no rationale for setting the stimulus doses as a function of intraictal peak heart rates (‘benchmark method’). The marked decline in heart rate at the end of most seizures is probably mediated by a baroreceptor reflex. PMID:23764036

  10. Attenuated post-exercise heart rate recovery in patients with systemic lupus erythematosus: the role of disease severity and beta-blocker treatment.

    PubMed

    Bienias, P; Ciurzyński, M; Chrzanowska, A; Dudzik-Niewiadomska, I; Irzyk, K; Oleszek, K; Kalińska-Bienias, A; Kisiel, B; Tłustochowicz, W; Pruszczyk, P

    2018-02-01

    Objective Sinus tachycardia is frequently reported in systemic lupus erythematosus (SLE), while there are limited data on post-exercise ability to slow heart rate (i.e. heart rate recovery, HRR) in this group of patients. Methods We studied consecutive 70 patients with SLE and 30 healthy controls. All examined individuals underwent detailed clinical examination, echocardiography, Holter monitoring with heart rate variability and treadmill stress test using Bruce's protocol. HRR values were calculated as the difference between maximum HR during exercise and HR at the first (HRR1) and third (HRR3) minute of rest. Individuals with coronary artery disease, diabetes mellitus and suspected pulmonary hypertension were excluded from further analysis ( n = 15). Results Fifty-five SLE patients were eligible for this study: aged 41.5 ± 12.4 years, 87.3% women, SLICC/ACR-DI score 3.58 ± 1.85. In the SLE group 36.4% patients received beta-blockers, usually for previously detected sinus tachycardia and/or arterial hypertension. Mean HRR1 (36.9 ± 12.6 vs 49.5 ± 18.6, p = 0.0004) and HRR3 (55.5 ± 14.3 vs 69.2 ± 16.4, p = 0.0001) were significantly lower in SLE than in healthy individuals. Significantly negative correlations between SLICC/ACR-DI score and HRR1 ( r = -0.299, p = 0.01), HRR3 ( r = -0.361, p = 0.001) and exercise capacity ( r = -0.422, p < 0.0001) were revealed. Additionally, beta-blocker treatment was also revealed to alter significantly HRR1, HRR3 and exercise capacity in SLE. Conclusion Patients with SLE are characterized by attenuated HRR after exercise. In our study impaired HRR was associated with disease severity and beta-blocker treatment and probably with disease duration. The use of HRR assessment in SLE can be used as an additional marker of cardiac autonomic nervous system dysfunction.

  11. Right ventricular outflow tract tachycardia due to a somatic cell mutation in G protein subunitalphai2.

    PubMed Central

    Lerman, B B; Dong, B; Stein, K M; Markowitz, S M; Linden, J; Catanzaro, D F

    1998-01-01

    Idiopathic ventricular tachycardia is a generic term that describes the various forms of ventricular arrhythmias that occur in patients without structural heart disease and in the absence of the long QT syndrome. Many of these tachycardias are focal in origin, localize to the right ventricular outflow tract (RVOT), terminate in response to beta blockers, verapamil, vagal maneuvers, and adenosine, and are thought to result from cAMP-mediated triggered activity. DNA was prepared from biopsy samples obtained from myocardial tissue from a patient with adenosine-insensitive idiopathic ventricular tachycardia arising from the RVOT. Genomic sequences of the inhibitory G protein Galphai2 were determined after amplification by PCR and subcloning. A point mutation (F200L) in the GTP binding domain of the inhibitory G protein Galphai2 was identified in a biopsy sample from the arrhythmogenic focus. This mutation was shown to increase intracellular cAMP concentration and inhibit suppression of cAMP by adenosine. No mutations were detected in Galphai2 sequences from myocardial tissue sampled from regions remote from the origin of tachycardia, or from peripheral lymphocytes. These findings suggest that somatic cell mutations in the cAMP-dependent signal transduction pathway occurring during myocardial development may be responsible for some forms of idiopathic ventricular tachycardia. PMID:9637720

  12. Influence of ECG sampling rate in fetal heart rate variability analysis.

    PubMed

    De Jonckheere, J; Garabedian, C; Charlier, P; Champion, C; Servan-Schreiber, E; Storme, L; Debarge, V; Jeanne, M; Logier, R

    2017-07-01

    Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).

  13. Prognostic Factors in Severe Chagasic Heart Failure

    PubMed Central

    Costa, Sandra de Araújo; Rassi, Salvador; Freitas, Elis Marra da Madeira; Gutierrez, Natália da Silva; Boaventura, Fabiana Miranda; Sampaio, Larissa Pereira da Costa; Silva, João Bastista Masson

    2017-01-01

    Background Prognostic factors are extensively studied in heart failure; however, their role in severe Chagasic heart failure have not been established. Objectives To identify the association of clinical and laboratory factors with the prognosis of severe Chagasic heart failure, as well as the association of these factors with mortality and survival in a 7.5-year follow-up. Methods 60 patients with severe Chagasic heart failure were evaluated regarding the following variables: age, blood pressure, ejection fraction, serum sodium, creatinine, 6-minute walk test, non-sustained ventricular tachycardia, QRS width, indexed left atrial volume, and functional class. Results 53 (88.3%) patients died during follow-up, and 7 (11.7%) remained alive. Cumulative overall survival probability was approximately 11%. Non-sustained ventricular tachycardia (HR = 2.11; 95% CI: 1.04 - 4.31; p<0.05) and indexed left atrial volume ≥ 72 mL/m2 (HR = 3.51; 95% CI: 1.63 - 7.52; p<0.05) were the only variables that remained as independent predictors of mortality. Conclusions The presence of non-sustained ventricular tachycardia on Holter and indexed left atrial volume > 72 mL/m2 are independent predictors of mortality in severe Chagasic heart failure, with cumulative survival probability of only 11% in 7.5 years. PMID:28443956

  14. A Case of a Cardiac Resynchronization Therapy-Defibrillator Exhibiting a Lower and Alternately Variable Basic Rate.

    PubMed

    Iwazaki, Keigo; Kojima, Toshiya; Murasawa, Takahide; Yokota, Jun; Tanimoto, Hikaru; Matsuda, Jun; Fukuma, Nobuaki; Matsubara, Takumi; Shimizu, Yu; Oguri, Gaku; Hasumi, Eriko; Kubo, Hitoshi; Chang, Kyungho; Fujiu, Katsuhito; Komuro, Issei

    2018-05-30

    A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.

  15. Heart Rate Assessment Immediately after Birth.

    PubMed

    Phillipos, Emily; Solevåg, Anne Lee; Pichler, Gerhard; Aziz, Khalid; van Os, Sylvia; O'Reilly, Megan; Cheung, Po-Yin; Schmölzer, Georg M

    2016-01-01

    Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.

  16. Postural Orthostatic Tachycardia Syndrome and Its Unusual Presenting Complaints in Women: A Literature Minireview

    PubMed Central

    Sohail, Wafa; Hatipoglu, Betul; Wilson, Robert

    2018-01-01

    Postural orthostatic tachycardia syndrome (POTS) is a heterogeneous disorder of the autonomic nervous system that is defined by symptoms of orthostatic intolerance. According to the current criteria for adults, currently, POTS is defined as a heart rate increment of 30 beats/minute or more after 10 minutes of standing in the absence of orthostatic hypotension. There is a vast majority that remains misdiagnosed due to the heterogeneity of the disorder. Due to a lack of Food and Drug Administration (FDA) approved therapy, alternative therapies and over the counter medications are used to alleviate the symptoms. This is an uncommon presentation observed primarily in women, as it is more prevalent in females. PMID:29876157

  17. [Parahisian atrial tachycardia or atrioventricular nodal reentrant tachycardia with tendon of Todaro breakthrough?].

    PubMed

    Orczykowski, Michał; Jaworska-Wilczyńska, Maria; Urbanek, Piotr; Bodalski, Robert; Derejko, Paweł; Gajek, Jacek; Hryniewiecki, Tomasz; Szumowski, Lukasz; Walczak, Franciszek

    2010-08-01

    We present a case of a 61 year-old woman with tachycardia originating close to the His bundle where radiofrequency (RF) ablation may bear potential risk of atrioventricular (AV) block. In this case report we discuss the possibility of a AV nodal reciprocating tachycardia with tendon of Todaro breakthrough. Patient was safely and effectively treated with RF catheter ablation.

  18. Central α- and β-adrenoceptors modifying arterial blood pressure and heart rate in conscious cats

    PubMed Central

    Day, M.D.; Roach, A.G.

    1974-01-01

    1 In conscious unrestrained cats noradrenaline, α-methylnoradrenaline and clonidine, infused into the lateral cerebral ventricles (i.c.v.) caused dose-related falls in blood pressure and heart rate; both effects were abolished after i.c.v. phentolamine. 2 In 12 out of 20 cats, i.c.v. isoprenaline and salbutamol when given caused dose-related pressor responses and tachycardias. These effects were abolished after i.c.v. β-adrenoceptor blocking drugs but were unaffected by α-adrenoceptor blocking agents. 3 In 5 out of 20 cats, i.c.v. isoprenaline regularly produced dose-related falls in blood pressure with associated tachycardias; both effects were abolished after i.c.v. β-adrenoceptor blocking agents. 4 Intracerebroventricular dopamine produced cardiovascular responses which were qualitatively similar to those produced by i.c.v. isoprenaline. 5 Intracerebroventricular adrenaline produced complex responses in untreated animals but typical α-effects were obtained after prior i.c.v. treatment with a β-adrenoceptor blocking agent and typical β-effects after i.c.v. pretreatment with an α-adrenoceptor blocking agent. 6 The cardiovascular changes produced by i.c.v. β-adrenoceptor agonists were abolished after systemic administration of hexamethonium or bethanidine. 7 The results are discussed in the light of the mode of action of β-adrenoceptor stimulants and β-adrenoceptor blocking agents in the treatment of hypertension. PMID:4451747

  19. Heart rate dynamics in monoamine oxidase-A- and -B-deficient mice

    PubMed Central

    HOLSCHNEIDER, D. P.; SCREMIN, O. U.; CHIALVO, D. R.; CHEN, K.; SHIH, J. C.

    2014-01-01

    Heart rate (HR) dynamics were investigated in mice deficient in monoamine oxidase A and B, whose phenotype includes elevated tissue levels of norepinephrine, serotonin, dopamine, and phenylethylamine. In their home cages, spectral analysis of R-R intervals revealed more pronounced fluctuations at all frequencies in the mutants compared with wild-type controls, with a particular enhancement at 1–4 Hz. No significant genotypic differences in HR variability (HRV) or entropies calculated from Poincaré plots of the R-R intervals were noted. During exposure to the stress of a novel environment, HR increased and HRV decreased in both genotypes. However, mutants, unlike controls, demonstrated a rapid return to baseline HR during the 10-min exposure. Such modulation may result from an enhanced vagal tone, as suggested by the observation that mutants responded to cholinergic blockade with a decrease in HRV and a prolonged tachycardia greater than controls. Monoamine oxidase-deficient mice may represent a useful experimental model for studying compensatory mechanisms responsible for changes in HR dynamics in chronic states of high sympathetic tone. PMID:11959640

  20. Postoperative Tachycardia: Clinically Meaningful or Benign Consequence of Orthopedic Surgery?

    PubMed

    Sigmund, Alana E; Fang, Yixin; Chin, Matthew; Reynolds, Harmony R; Horwitz, Leora I; Dweck, Ezra; Iturrate, Eduardo

    2017-01-01

    To determine the clinical significance of tachycardia in the postoperative period. Individuals 18 years or older undergoing hip and knee arthroplasty were included in the study. Two data sets were collected from different time periods: development data set from January 1, 2011, through December 31, 2011, and validation data set from December 1, 2012, through September 1, 2014. We used the development data set to identify the optimal definition of tachycardia with the strongest association with the vascular composite outcome (pulmonary embolism and myocardial necrosis and infarction). The predictive value of this definition was assessed in the validation data set for each outcome of interest, pulmonary embolism, myocardial necrosis and infarction, and infection using multiple logistic regression to control for known risk factors. In 1755 patients in the development data set, a maximum heart rate (HR) greater than 110 beats/min was found to be the best cutoff as a correlate of the composite vascular outcome. Of the 4621 patients who underwent arthroplasty in the validation data set, 40 (0.9%) had pulmonary embolism. The maximum HR greater than 110 beats/min had an odds ratio (OR) of 9.39 (95% CI, 4.67-18.87; sensitivity, 72.5%; specificity, 78.0%; positive predictive value, 2.8%; negative predictive value, 99.7%) for pulmonary embolism. Ninety-seven patients (2.1%) had myocardial necrosis (elevated troponin). The maximum HR greater than 110 beats/min had an OR of 4.71 (95% CI, 3.06-7.24; sensitivity, 47.4%; specificity, 78.1%; positive predictive value, 4.4%; negative predictive value, 98.6%) for this outcome. Thirteen (.3%) patients had myocardial infarction according to our predetermined definition, and the maximum HR greater than 110 beats/min had an OR of 1.72 (95% CI, 0.47-6.27). Postoperative tachycardia within the first 4 days of surgery should not be dismissed as a postoperative variation in HR, but may precede clinically significant adverse outcomes

  1. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  2. ACONITE-INDUCED VENTRICULAR TACHYCARDIA DURING RADIATION SICKNESS (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jurkovic, V.; Vokrouhlicky, L.; Belobradek, Z.

    1962-10-01

    In order to study cardiac excitability and the effects of procaine, ventricular tachycardia was induced by intramyocardial injection of 0.05 ml 50% aconite solution in irradiated and nonirradiated rabbits of both sexes. Tracheotomy and thoracotomy were performed to facilitate access to the heart and to establish artificial respiration through a tracheal tube. Narcosis was induced by urethane. Electrocardiograms were made at various stages in both control and irradiated animals; the former showed no change in preliminary phases of the experiment. Procaine was administered by subcutaneous injection, bilateral vagosympathetic infiltration, or slow intravenous infusion. Its therapeutic effect was determined by givingmore » it 5 min after trachycardia occurred, and its preventive action by giving it 5 min before. The x irradiation rate was 16.6 r/min, to a total dose of 1000 r. On the 3rd day after irradiation, the therapeutic effect of procaine after intramuscular injection was seen as a 50% normalization of heart action, with less by other routes of administration; its preventive effect was seen as a 58% normalization following slow intravenous infusion but was insignificant by other routes. Six days after irradiation, at the peak of radiation sickness, procaine's therapeutic and preventive actions had almost disappeared; its intravenous therapeutic application gave 25% normalization and its intramuscular preventive action provided 20% normalization of heart rate. However, on the 6th day, a profibrillatory effect was observed, especially in the therapeutic vagosympathetic infiltration technique and the preventive use by slow intravenous infusion. Suggested explanations of the reversal are: change in excitability of myocardium when it is irradiated, or change in effect of procaine when the whole organism is irradiated. Results favor the first explanation. (BBB)« less

  3. Passive fetal heart rate monitoring apparatus and method with enhanced fetal heart beat discrimination

    NASA Technical Reports Server (NTRS)

    Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)

    1996-01-01

    An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.

  4. Passive fetal heart rate monitoring apparatus and method with enhanced fetal heart beat discrimination

    NASA Technical Reports Server (NTRS)

    Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)

    1994-01-01

    An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.

  5. Heart rate reduction and longevity in mice.

    PubMed

    Gent, Sabine; Kleinbongard, Petra; Dammann, Philip; Neuhäuser, Markus; Heusch, Gerd

    2015-03-01

    Heart rate correlates inversely with life span across all species, including humans. In patients with cardiovascular disease, higher heart rate is associated with increased mortality, and such patients benefit from pharmacological heart rate reduction. However, cause-and-effect relationships between heart rate and longevity, notably in healthy individuals, are not established. We therefore prospectively studied the effects of a life-long pharmacological heart rate reduction on longevity in mice. We hypothesized, that the total number of cardiac cycles is constant, and that a 15% heart rate reduction might translate into a 15% increase in life span. C57BL6/J mice received either placebo or ivabradine at a dose of 50 mg/kg/day in drinking water from 12 weeks to death. Heart rate and body weight were monitored. Autopsy was performed on all non-autolytic cadavers, and parenchymal organs were evaluated macroscopically. Ivabradine reduced heart rate by 14% (median, interquartile range 12-15%) throughout life, and median life span was increased by 6.2% (p = 0.01). Body weight and macroscopic findings were not different between placebo and ivabradine. Life span was not increased to the same extent as heart rate was reduced, but nevertheless significantly prolonged by 6.2%.

  6. Evolving changes in fetal heart rate variability and brain injury after hypoxia-ischaemia in preterm fetal sheep.

    PubMed

    Yamaguchi, Kyohei; Lear, Christopher A; Beacom, Michael J; Ikeda, Tomoaki; Gunn, Alistair J; Bennet, Laura

    2018-01-08

    Fetal heart rate variability is a critical index of fetal wellbeing. Suppression of heart rate variability may provide prognostic information on the risk of hypoxic-ischaemic brain injury after birth. In the present study, we report the evolution of fetal heart rate variability after both mild and severe hypoxia-ischaemia. Both mild and severe hypoxia-ischaemia were associated with an initial, brief suppression of multiple measures of heart rate variability. This was followed by normal or increased levels of heart rate variability during the latent phase of injury. Severe hypoxia-ischaemia was subsequently associated with the prolonged suppression of measures of heart rate variability during the secondary phase of injury, which is the period of time when brain injury is no longer treatable. These findings suggest that a biphasic pattern of heart rate variability may be an early marker of brain injury when treatment or intervention is probably most effective. Hypoxia-ischaemia (HI) is a major contributor to preterm brain injury, although there are currently no reliable biomarkers for identifying infants who are at risk. We tested the hypothesis that fetal heart rate (FHR) and FHR variability (FHRV) would identify evolving brain injury after HI. Fetal sheep at 0.7 of gestation were subjected to either 15 (n = 10) or 25 min (n = 17) of complete umbilical cord occlusion or sham occlusion (n = 12). FHR and four measures of FHRV [short-term variation, long-term variation, standard deviation of normal to normal R-R intervals (SDNN), root mean square of successive differences) were assessed until 72 h after HI. All measures of FHRV were suppressed for the first 3-4 h in the 15 min group and 1-2 h in the 25 min group. Measures of FHRV recovered to control levels by 4 h in the 15 min group, whereas the 25 min group showed tachycardia and an increase in short-term variation and SDNN from 4 to 6 h after occlusion. The measures of FHRV then progressively

  7. The effects of heart rate control in chronic heart failure with reduced ejection fraction.

    PubMed

    Grande, Dario; Iacoviello, Massimo; Aspromonte, Nadia

    2018-07-01

    Elevated heart rate has been associated with worse prognosis both in the general population and in patients with heart failure. Heart rate is finely modulated by neurohormonal signals and it reflects the balance between the sympathetic and the parasympathetic limbs of the autonomic nervous system. For this reason, elevated heart rate in heart failure has been considered an epiphenomenon of the sympathetic hyperactivation during heart failure. However, experimental and clinical evidence suggests that high heart rate could have a direct pathogenetic role. Consequently, heart rate might act as a pathophysiological mediator of heart failure as well as a marker of adverse outcome. This hypothesis has been supported by the observation that the positive effect of beta-blockade could be linked to the degree of heart rate reduction. In addition, the selective heart rate control with ivabradine has recently been demonstrated to be beneficial in patients with heart failure and left ventricular systolic dysfunction. The objective of this review is to examine the pathophysiological implications of elevated heart rate in chronic heart failure and explore the mechanisms underlying the effects of pharmacological heart rate control.

  8. Hemodynamic and symptomatic effects of acute interventions on tilt in patients with postural tachycardia syndrome

    NASA Technical Reports Server (NTRS)

    Gordon, V. M.; Opfer-Gehrking, T. L.; Novak, V.; Low, P. A.

    2000-01-01

    A variety of approaches have been used to alleviate symptoms in postural tachycardia syndrome (POTS). Drugs reported to be of benefit include midodrine, propranolol, clonidine, and phenobarbital. Other measures used include volume expansion and physical countermaneuvers. These treatments may influence pathophysiologic mechanisms of POTS such as alpha-receptor dysfunction, beta-receptor supersensitivity, venous pooling, and brainstem center dysfunction. The authors prospectively studied hemodynamic indices and symptom scores in patients with POTS who were acutely treated with a variety of interventions. Twenty-one subjects who met the criteria for POTS were studied (20 women, 1 man; mean age, 28.7 +/- 6.8 y; age range, 14-39 y). Patients were studied with a 5-minute head-up tilt protocol, ECG monitoring, and noninvasive beat-to-beat blood pressure monitoring, all before and after the administration of an intervention (intravenous saline, midodrine, propranolol, clonidine, or phenobarbital). The hemodynamic indices studied were heart rate (ECG) and systolic, mean, and diastolic blood pressure. Patients used a balanced verbal scale to record any change in their symptoms between the tilts. Symptom scores improved significantly after the patients received midodrine and saline. Midodrine and propranolol reduced the resting heart rate response to tilt (p <0.005) and the immediate and 5-minute heart rate responses to tilt (p <0.002). Clonidine accentuated the immediate decrease in blood pressure on tilt up (p <0.05). It was concluded that midodrine and intravenous saline are effective in decreasing symptoms on tilt in patients with POTS when given acutely. Effects of treatments on heart rate and blood pressure responses generally reflected the known pharmacologic mechanisms of the agents.

  9. Ventricular tachycardia

    MedlinePlus

    ... called ablation ) may be done. An implantable cardioverter defibrillator (ICD) may be used. It is a device ... V tach; Tachycardia - ventricular Patient Instructions Implantable cardioverter defibrillator - discharge Images Implantable cardioverter-defibrillator References Garan H. ...

  10. Rhesus monkey heart rate during exercise

    NASA Technical Reports Server (NTRS)

    Delorge, J.; Thach, J. S., Jr.

    1972-01-01

    Various schedules of reinforcement and their relation to heart rates of rhesus monkeys during exercise are described. All the reinforcement schedules produced 100 per cent or higher increments in the heart rates of the monkeys during exercise. Resting heart rates were generally much lower than those previously reported, which was attributed to the lack of physical restraint of the monkeys during recording.

  11. [Wide QRS tachycardia preceded by pacemaker spikes].

    PubMed

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  12. Postural tachycardia in hypermobile Ehlers-Danlos syndrome: A distinct subtype?

    PubMed

    Miglis, Mitchell G; Schultz, Brittany; Muppidi, Srikanth

    2017-12-01

    It is not clear if patients with postural tachycardia syndrome (POTS) and Ehlers-Danlos syndrome (hEDS) differ from patients with POTS due to other etiologies. We compared the results of autonomic testing and healthcare utilization in POTS patients with and without hEDS. Patients with POTS+hEDS (n=20) and POTS controls without hypermobility (n=20) were included in the study. All patients underwent autonomic testing, and the electronic medical records were reviewed to determine the number and types of medications patients were taking, as well as the number of outpatient, emergency department, and inpatient visits over the prior year. Patients with hEDS had twice as many outpatient visits (21 v. 10, p=0.012), were taking more prescription medications (8 vs. 5.5, p=0.030), and were more likely to see a pain physician (70% vs 25%, p=0.005). Autonomic testing demonstrated a slight reduction in heart rate variability and slightly lower blood pressures on tilt table testing in hEDS patients, however for most patients these variables remained within the range of normal. Orthostatic tachycardia on tilt table testing was greater in POTS controls (46bpm vs 39bpm, p=0.018). Abnormal QSweat responses were common in both groups (38% of POTS+hEDS and 36% of POTS controls). While autonomic testing results were not significantly different between groups, patients with POTS+hEDS took more medications and had greater markers of healthcare utilization, with chronic pain likely playing a prominent role. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Using the 12-lead ECG to localize the origin of ventricular and atrial tachycardias: part 1. Focal atrial tachycardia.

    PubMed

    Teh, Andrew W; Kistler, Peter M; Kalman, Jonathan M

    2009-06-01

    Focal atrial tachycardia is an unusual form of supraventricular tachycardia arising from defined anatomic locations and sites within the atria. Although recent advances in mapping technology have facilitated successful ablation, the surface ECG remains an important aid in localizing the focus. This review discusses the use of P-wave morphology on surface ECG to localize the site of focal atrial tachycardia.

  14. Fetal heart rate and fetal heart rate variability in Lipizzaner broodmares.

    PubMed

    Baska-Vincze, Boglárka; Baska, Ferenc; Szenci, Ottó

    2015-03-01

    Monitoring fetal heart rate (FHR) and fetal heart rate variability (FHRV) helps to understand and evaluate normal and pathological conditions in the foal. The aim of this study was to establish normal heart rate reference values for the ongoing equine pregnancy and to perform a heart rate variability (HRV) time-domain analysis in Lipizzaner mares. Seventeen middle- and late-term (days 121-333) pregnant Lipizzaner mares were examined using fetomaternal electrocardiography (ECG). The mean FHR (P = 0.004) and the standard deviation of FHR (P = 0.012) significantly decreased during the pregnancy. FHR ± SD values decreased from 115 ± 35 to 79 ± 9 bpm between months 5 and 11. Our data showed that HRV in the foal decreased as the pregnancy progressed, which is in contrast with the findings of earlier equine studies. The standard deviation of normal-normal intervals (SDNN) was higher (70 ± 25 to 166 ± 108 msec) than described previously. The root mean square of successive differences (RMSSD) decreased from 105 ± 69 to 77 ± 37 msec between the 5th and 11th month of gestation. Using telemetric ECG equipment, we could detect equine fetal heartbeat on day 121 for the first time. In addition, the large differences observed in the HR values of four mare-fetus pairs in four consecutive months support the assumption that there might be 'high-HR' and 'low-HR' fetuses in horses. It can be concluded that the analysis of FHR and FHRV is a promising tool for the assessment of fetal well-being but the applicability of these parameters in the clinical setting and in studs requires further investigation.

  15. Postural Orthostatic Tachycardia Syndrome during pregnancy: A systematic review of the literature.

    PubMed

    Morgan, Kate; Chojenta, Catherine; Tavener, Meredith; Smith, Angela; Loxton, Deb

    2018-05-09

    Postural Orthostatic Tachycardia Syndrome is most commonly seen in women of child bearing age, however little is known about its effects in pregnancy. A systematic review was conducted in March 2015 and updated in February 2018. Medline, Embase, PsychInfo, CINHAL, and the Cochrane Library were searched from database inception. The ClinicalTrials.gov site and bibliographies were searched. MeSH and Emtree headings and keywords included; Postural Orthostatic Tachycardia Syndrome, Postural Tachycardia Syndrome, and were combined with pregnancy and pregnancy related subject headings and keywords. Searches were limited to English. Eligible articles contained key words within the title and or abstract. Articles were excluded if Postural Orthostatic Tachycardia Syndrome was not pre-existing. Eleven articles were identified as eligible for inclusion. Studies were appraised using the PRISMA 2009 guidelines. The overall quality of evidence was poor using the NHMRC Evidence Grading Matrix, which was attributed to small sample sizes and mostly observational studies, emphasizing the need for future high quality research. Findings in this review must be used with caution due to the poor quality of the literature available. Postural Orthostatic Tachycardia Syndrome should not be a contraindication to pregnancy. Symptom course is variable during pregnancy and the post-partum period. Continuing pre-conception medication may help symptoms, with no significant risks reported. Obstetric complications, not Postural Orthostatic Tachycardia Syndrome, should dictate mode of delivery. Postural Orthostatic Tachycardia Syndrome did not appear to affect the rate of adverse events. These results are important in determining appropriate management and care in this population. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Heart rate variability and aerobic fitness.

    PubMed

    De Meersman, R E

    1993-03-01

    Heart rate variability, a noninvasive marker of parasympathetic activity, diminishes with aging and is augmented after exercise training. Whether habitual exercise over time can attenuate this loss is unknown. This cross-sectional investigation compared 72 male runners, aged 15 to 83 to 72 age- and weight-matched sedentary control subjects for the amplitude of their heart rate variability. Heart rate variability was assessed during rest while subjects were breathing at a rate of 6 breaths per minute and at an augmented tidal volume (tidal volume = 30% of vital capacity). Fitness levels were assessed with on-line, open-circuit spirometry while subjects were performing an incremental stress test. Overall results between the two groups showed that the physically active group had significantly higher fitness levels (p < 0.001), which were associated with significantly higher levels of heart rate variability, when compared with their sedentary counterparts (p < 0.001). These findings provide suggestive evidence for habitual aerobic exercise as a beneficial modulator of heart rate variability in an aging population.

  17. Heart Rate Sensor for Freshwater Mussels

    NASA Astrophysics Data System (ADS)

    Just, C. L.; Vial, D. P.; Kruger, A.; Niemeier, J. J.; Lee, H. W.; Schroer, H. W.

    2014-12-01

    Researchers have long been interested the cardiac activity of mollusks. First, it is important as a basic measure of the animal's metabolism. Further, activities such as feeding and burrowing affect heart rate, as do environmental factors such as water salinity, water temperature, exposure, and predation. We have developed a small, noninvasive sensor for measuring freshwater mussel heart rate. Its working principle is as follows. An infrared (IR) light-emitting diode is placed in contact with the mussel shell. Some of the IR penetrates through the shell, reflects off internal organs, and traverses back. A photodetector detects this IR, and electronics condition the signal. The heartbeat of the animal modulates the IR, allowing one to measure the heart rate. The technique is widely-used in finger heart-rate monitors in humans. The sensors do not have to be positioned above the heart and several locations on the mussel shell work well. The sensor is small (8 mm × 10 mm) and consumes less than 1 mA, and has a simple one-wire interface that allows for easy integration into data acquisition hardware. We present heart rate measurements for the common pocketbook (lampsilis cardium) freshwater mussel.

  18. Catheter ablation of junctional ectopic tachycardia in children, with preservation of atrioventricular conduction.

    PubMed

    Emmel, M; Sreeram, N; Brockmeier, K

    2005-04-01

    Idiopathic junctional ectopic tachycardia is a rare arrhythmia in children. Several studies have demonstrated that drug therapy is often ineffective and sometimes the only achieved effect is rate control. Early presentation and frequent recurrence are associated with adverse outcome. Three consecutive children, aged 9, 7 and 12 years respectively, underwent radiofrequency catheter ablation for junctional ectopic tachycardia, after having failed antiarrhythmic drug therapy. The entire His bundle was plotted out and marked, using the Localisa navigation system. The arrhythmia was readily and repeatedly inducible using intravenous isoprenaline infusion and the site of earliest retrograde conduction during tachycardia could be assessed. Ablations were performed in sinus rhythm, empirically targeting the site of earliest retrograde conduction during tachycardia. This approach was successful in abolishing tachyarrhythmia in the first two patients, in whom the successful ablation site was located superoparaseptally. In the third patient, junctional ectopic tachycardia was inducible, despite abolishing retrograde atrial activation, in a septal location on the tricuspid valve annulus. Further ablations in the superoparaseptal region, closer to the His bundle, were successful in rendering tachyarrhythmia noninducible. Over a median follow-up of 10 months, none of the patients has had recurrence of arrhythmia, despite discontinuing all antiarrhythmic medications. Radio frequency catheter ablation of junctional ectopic tachycardia is feasible with preservation of atrioventricular conduction.

  19. Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction.

    PubMed

    Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul

    2006-04-01

    The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.

  20. Estimation of heart rate and heart rate variability from pulse oximeter recordings using localized model fitting.

    PubMed

    Wadehn, Federico; Carnal, David; Loeliger, Hans-Andrea

    2015-08-01

    Heart rate variability is one of the key parameters for assessing the health status of a subject's cardiovascular system. This paper presents a local model fitting algorithm used for finding single heart beats in photoplethysmogram recordings. The local fit of exponentially decaying cosines of frequencies within the physiological range is used to detect the presence of a heart beat. Using 42 subjects from the CapnoBase database, the average heart rate error was 0.16 BPM and the standard deviation of the absolute estimation error was 0.24 BPM.

  1. Atrial Tachycardias Following Atrial Fibrillation Ablation

    PubMed Central

    Sághy, László; Tutuianu, Cristina; Szilágyi, Judith

    2015-01-01

    One of the most important proarrhythmic complications after left atrial (LA) ablation is regular atrial tachycardia (AT) or flutter. Those tachycardias that occur after atrial fibrillation (AF) ablation can cause even more severe symptoms than those from the original arrhythmia prior to the index ablation procedure since they are often incessant and associated with rapid ventricular response. Depending on the method and extent of LA ablation and on the electrophysiological properties of underlying LA substrate, the reported incidence of late ATs is variable. To establish the exact mechanism of these tachycardias can be difficult and controversial but correlates with the ablation technique and in the vast majority of cases the mechanism is reentry related to gaps in prior ablation lines. When tachycardias occur, conservative therapy usually is not effective, radiofrequency ablation procedure is mostly successful, but can be challenging, and requires a complex approach. PMID:25308808

  2. Influence of energy drinks and alcohol on post-exercise heart rate recovery and heart rate variability.

    PubMed

    Wiklund, Urban; Karlsson, Marcus; Oström, Mats; Messner, Torbjörn

    2009-01-01

    Media have anecdotally reported that drinking energy drinks in combination with alcohol and exercise could cause sudden cardiac death. This study investigated changes in the electrocardiogram (ECG) and heart rate variability after intake of an energy drink, taken in combination with alcohol and exercise. Ten healthy volunteers (five men and five women aged 19-30) performed maximal bicycle ergometer exercise for 30 min after: (i) intake of 0.75 l of an energy drink mixed with alcohol; (ii) intake of energy drink; and, (iii) no intake of any drink. ECG was continuously recorded for analysis of heart rate variability and heart rate recovery. No subject developed any clinically significant arrhythmias. Post-exercise recovery in heart rate and heart rate variability was slower after the subjects consumed energy drink and alcohol before exercise, than after exercise alone. The healthy subjects developed blunted cardiac autonomic modulation after exercising when they had consumed energy drinks mixed with alcohol. Although they did not develop any significant arrhythmia, individuals predisposed to arrhythmia by congenital or other rhythm disorders could have an increased risk for malignant cardiac arrhythmia in similar situations.

  3. Effect of Loss of Heart Rate Variability on T-Wave Heterogeneity and QT Variability in Heart Failure Patients: Implications in Ventricular Arrhythmogenesis.

    PubMed

    Nayyar, Sachin; Hasan, Muhammad A; Roberts-Thomson, Kurt C; Sullivan, Thomas; Baumert, Mathias

    2017-06-01

    Heart rate variability (HRV) modulates dynamics of ventricular repolarization. A diminishing value of HRV is associated with increased vulnerability to life-threatening ventricular arrhythmias, however the causal relationship is not well-defined. We evaluated if fixed-rate atrial pacing that abolishes the effect of physiological HRV, will alter ventricular repolarization wavefronts and is relevant to ventricular arrhythmogenesis. The study was performed in 16 subjects: 8 heart failure patients with spontaneous ventricular tachycardia [HFVT], and 8 subjects with structurally normal hearts (H Norm ). The T-wave heterogeneity descriptors [total cosine angle between QRS and T-wave loop vectors (TCRT, negative value corresponds to large difference in the 2 loops), T-wave morphology dispersion, T-wave loop dispersion] and QT intervals were analyzed in a beat-to-beat manner on 3-min records of 12-lead surface ECG at baseline and during atrial pacing at 80 and 100 bpm. The global T-wave heterogeneity was expressed as mean values of each of the T-wave morphology descriptors and variability in QT intervals (QTV) as standard deviation of QT intervals. Baseline T-wave morphology dispersion and QTV were higher in HFVT compared to H Norm subjects (p ≤ 0.02). While group differences in T-wave morphology dispersion and T-wave loop dispersion remained unaltered with atrial pacing, TCRT tended to fall more in HFVT patients compared to H Norm subjects (interaction p value = 0.086). Atrial pacing failed to reduce QTV in both groups, however group differences were augmented (p < 0.0001). Atrial pacing and consequent loss of HRV appears to introduce unfavorable changes in ventricular repolarization in HFVT subjects. It widens the spatial relationship between wavefronts of ventricular depolarization and repolarization. This may partly explain the concerning relation between poorer HRV and the risk of ventricular arrhythmias.

  4. Heart Rate and Respiratory Rate Influence on Heart Rate Variability Repeatability: Effects of the Correction for the Prevailing Heart Rate

    PubMed Central

    Gąsior, Jakub S.; Sacha, Jerzy; Jeleń, Piotr J.; Zieliński, Jakub; Przybylski, Jacek

    2016-01-01

    Background: Since heart rate variability (HRV) is associated with average heart rate (HR) and respiratory rate (RespRate), alterations in these parameters may impose changes in HRV. Hence the repeatability of HRV measurements may be affected by differences in HR and RespRate. The study aimed to evaluate HRV repeatability and its association with changes in HR and RespRate. Methods: Forty healthy volunteers underwent two ECG examinations 7 days apart. Standard HRV indices were calculated from 5-min ECG recordings. The ECG-derived respiration signal was estimated to assess RespRate. To investigate HR impact on HRV, HRV parameters were corrected for prevailing HR. Results: Differences in HRV parameters between the measurements were associated with the changes in HR and RespRate. However, in multiple regression analysis only HR alteration proved to be independent determinant of the HRV differences—every change in HR by 1 bpm changed HRV values by 16.5% on average. After overall removal of HR impact on HRV, coefficients of variation of the HRV parameters significantly dropped on average by 26.8% (p < 0.001), i.e., by the same extent HRV reproducibility improved. Additionally, the HRV correction for HR decreased association between RespRate and HRV. Conclusions: In stable conditions, HR but not RespRate is the most powerful factor determining HRV reproducibility and even a minimal change of HR may considerably alter HRV. However, the removal of HR impact may significantly improve HRV repeatability. The association between HRV and RespRate seems to be, at least in part, HR dependent. PMID:27588006

  5. Nadolol decreases the incidence and severity of ventricular arrhythmias during exercise stress testing compared with β1-selective β-blockers in patients with catecholaminergic polymorphic ventricular tachycardia.

    PubMed

    Leren, Ida S; Saberniak, Jørg; Majid, Eman; Haland, Trine F; Edvardsen, Thor; Haugaa, Kristina H

    2016-02-01

    Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inheritable cardiac disease predisposing to malignant ventricular arrhythmias. We aimed to explore the incidence and severity of ventricular arrhythmias in patients with CPVT before the initiation of β-blocker treatment, when treated with β1-selective β-blockers, and when treated with nadolol. In this study, 34 patients with CPVT were included (mean age 34 ± 19 years; 15 (44%) women; 30 (88%) ryanodine receptor 2 variant positive). We performed 3 bicycle exercise stress tests in each patient: (1) before the initiation of β-blocker treatment, (2) after >6 weeks of treatment with β1-selective β-blockers and (3) after >6 weeks of treatment with nadolol. We recorded resting and maximum heart rates and the most severe ventricular arrhythmia occurring. Severity of arrhythmias was scored as 1 point for no arrhythmias or only single ventricular extrasystoles, 2 points for >10 ventricular extrasystoles per minute or bigeminy, 3 points for couplets, and 4 points for nonsustained ventricular tachycardia or sustained ventricular tachycardia. Resting heart rate was similar during treatment with nadolol and β1-selective β-blockers (54 ± 10 beats/min vs 56 ± 14 beats/min; P = .50), while maximum heart rate was lower during treatment with nadolol compared with β1-selective β-blockers (122 ± 21 beats/min vs 139 ± 24 beats/min; P = .001). Arrhythmias during exercise stress testing were less severe during treatment with nadolol compared with during treatment with β1-selective β-blockers (arrhythmic score 1.6 ± 0.9 vs 2.5 ± 0.8; P < .001) and before the initiation of β-blocker treatment (arrhythmic score 1.6 ± 0.9 vs 2.7 ± 0.9; P = .001); however, no differences were observed during treatment with β1-selective β-blockers compared with before the initiation of β-blocker treatment (arrhythmic score 2.5 ± 0.8 vs 2.7 ± 0.9; P = .46). The incidence and severity of ventricular arrhythmias decreased

  6. Estimation of the rate of oxygen consumption of the common eider duck (Somateria mollissima), with some measurements of heart rate during voluntary dives.

    PubMed

    Hawkins, P A; Butler, P J; Woakes, A J; Speakman, J R

    2000-09-01

    The relationship between heart rate (f(H)) and rate of oxygen consumption (V(O2)) was established for a marine diving bird, the common eider duck (Somateria mollissima), during steady-state swimming and running exercise. Both variables increased exponentially with speed during swimming and in a linear fashion during running. Eleven linear regressions of V(O2) (ml kg(-1 )min(-1)) on f(H) (beats min(-1)) were obtained: five by swimming and six by running the birds. The common regression was described by V(O2)=10.1 + 0.15f(H) (r(2)=0.46, N=272, P<0.0001). The accuracy of this relationship for predicting mean V(O2) was determined for a group of six birds by recording f(H) continuously over a 2-day period and comparing estimated V(O2) obtained using the common regression with (i) V(O2) estimated using the doubly labelled water technique (DLW) and (ii) V(O2) measured using respirometry. A two-pool model produced the most accurate estimated V(O2) using DLW. Because of individual variability within mean values of V(O2) estimated using both techniques, there was no significant difference between mean V(O2) estimated using f(H) or DLW and measured V(O2) values (P>0.2), although individual errors were substantially less when f(H) was used rather than DLW to estimate V(O2). Both techniques are, however, only suitable for estimating mean V(O2) for a group of animals, not for individuals. Heart rate and behaviour were monitored during a bout of 63 voluntary dives by one female bird in an indoor tank 1.7 m deep. Tachycardia occurred both in anticipation of and following each dive. Heart rate decreased before submersion but was above resting values for the whole of the dive cycle. Mean f(H) at mean dive duration was significantly greater than f(H) while swimming at maximum sustainable surface speeds. Heart rate was used to estimate mean V(O2) during the dive cycle and to predict aerobic dive limit (ADL) for shallow dives.

  7. Accuracy of smartphone apps for heart rate measurement.

    PubMed

    Coppetti, Thomas; Brauchlin, Andreas; Müggler, Simon; Attinger-Toller, Adrian; Templin, Christian; Schönrath, Felix; Hellermann, Jens; Lüscher, Thomas F; Biaggi, Patric; Wyss, Christophe A

    2017-08-01

    Background Smartphone manufacturers offer mobile health monitoring technology to their customers, including apps using the built-in camera for heart rate assessment. This study aimed to test the diagnostic accuracy of such heart rate measuring apps in clinical practice. Methods The feasibility and accuracy of measuring heart rate was tested on four commercially available apps using both iPhone 4 and iPhone 5. 'Instant Heart Rate' (IHR) and 'Heart Fitness' (HF) work with contact photoplethysmography (contact of fingertip to built-in camera), while 'Whats My Heart Rate' (WMH) and 'Cardiio Version' (CAR) work with non-contact photoplethysmography. The measurements were compared to electrocardiogram and pulse oximetry-derived heart rate. Results Heart rate measurement using app-based photoplethysmography was performed on 108 randomly selected patients. The electrocardiogram-derived heart rate correlated well with pulse oximetry ( r = 0.92), IHR ( r = 0.83) and HF ( r = 0.96), but somewhat less with WMH ( r = 0.62) and CAR ( r = 0.60). The accuracy of app-measured heart rate as compared to electrocardiogram, reported as mean absolute error (in bpm ± standard error) was 2 ± 0.35 (pulse oximetry), 4.5 ± 1.1 (IHR), 2 ± 0.5 (HF), 7.1 ± 1.4 (WMH) and 8.1 ± 1.4 (CAR). Conclusions We found substantial performance differences between the four studied heart rate measuring apps. The two contact photoplethysmography-based apps had higher feasibility and better accuracy for heart rate measurement than the two non-contact photoplethysmography-based apps.

  8. Treatment of out-of-hospital supraventricular tachycardia: adenosine vs verapamil.

    PubMed

    Brady, W J; DeBehnke, D J; Wickman, L L; Lindbeck, G

    1996-06-01

    To compare the use of adenosine and the use of verapamil as out-of-hospital therapy for supraventricular tachycardia (SVT). A period of prospective adenosine use (March 1993 to February 1994) was compared with a historical control period of verapamil use (March 1990 to February 1991) for SVT. Data were obtained for SVT patients treated in a metropolitan, fire-department-based paramedic system serving a population of approximately 1 million persons. Standard drug protocols were used and patient outcomes (i.e., conversion rates, complications, and recurrences) were monitored. During the adenosine treatment period, 105 patients had SVT; 87 (83%) received adenosine, of whom 60 (69%) converted to a sinus rhythm (SR). Vagal maneuvers (VM) resulted in restoration of SR in 8 patients (7.6%). Some patients received adenosine for non-SVT rhythms: 7 sinus tachycardia, 18 atrial fibrilation, 7 wide-complex tachycardia (WCT), and 2 ventricular tachycardia; no non-SVT rhythm converted to SR and none of these patients experienced an adverse effect. Twenty-five patients were hemodynamically unstable (systolic blood pressure < 90 mm Hg), with 20 receiving drug and 13 converting to SR; 8 patients required electrical cardioversion. Four patients experienced adverse effects related to adenosine (chest pain dyspnea, prolonged bradycardia, and ventricular tachycardia). In the verapamil period, 106 patients had SVT: 52 (49%) received verapamil (p < 0.001, compared with the adenosine period), of whom 43 (88%) converted to SR (p = 0.11). Two patients received verapamil for WCT; neither converted to SR and both experienced cardiovascular collapse. VM resulted in restoration of SR in 12 patients (11.0%) (p = 0.52). Sixteen patients were hemodynamically unstable, with 5 receiving drug (p = 0.005) and 5 converting to SR; 9 patients required electrical cardioversion (p = 0.48). Four patients experienced adverse effects related to verapamil (hypotension ventricular tachycardia, ventricular

  9. Mechanism of polyuria and natriuresis in atrioventricular nodal tachycardia.

    PubMed Central

    Canepa-Anson, R; Williams, M; Marshall, J; Mitsuoka, T; Lightman, S; Sutton, R

    1984-01-01

    A woman with tachycardia associated with polyuria was investigated. Electrophysiological analysis showed that the tachycardia was an atrioventricular nodal re-entrant tachycardia. Programmed stimulation was then used to provoke and sustain the tachycardia for 40 minutes. Polyuria, with an appreciable increase in free water clearance, was observed. This was associated with reduction in plasma and urinary arginine vasopressin concentrations. Appreciable natriuresis also developed. These results support the hypothesis that the polyuria with increased free water clearance and the natriuresis occurring during sustained tachycardia in man are due to inhibition of secretion of vasopressin and the release of natriuretic factor. PMID:6434116

  10. Idiopathic ventricular tachycardia and fibrillation.

    PubMed

    Belhassen, B; Viskin, S

    1993-06-01

    Important data have recently been added to our understanding of sustained ventricular tachyarrhythmias occurring in the absence of demonstrable heart disease. Idiopathic ventricular tachycardia (VT) is usually of monomorphic configuration and can be classified according to its site of origin as either right monomorphic (70% of all idiopathic VTs) or left monomorphic VT. Several physiopathological types of monomorphic VT can be presently individualized, according to their mode of presentation, their relationship to adrenergic stress, or their response to various drugs. The long-term prognosis is usually good. Idiopathic polymorphic VT is a much rarer type of arrhythmia with a less favorable prognosis. Idiopathic ventricular fibrillation may represent an underestimated cause of sudden cardiac death in ostensibly healty patients. A high incidence of inducibility of sustained polymorphic VT with programmed ventricular stimulation has been found by our group, but not by others. Long-term prognosis on Class IA antiarrhythmic medications that are highly effective at electrophysiologic study appears excellent.

  11. Earlier tachycardia onset in right than left mesial temporal lobe seizures.

    PubMed

    Kato, Kazuhiro; Jin, Kazutaka; Itabashi, Hisashi; Iwasaki, Masaki; Kakisaka, Yosuke; Aoki, Masashi; Nakasato, Nobukazu

    2014-10-07

    To clarify whether the presence and timing of peri-ictal heart rate (HR) change is a seizure lateralizing sign in patients with mesial temporal lobe epilepsy (mTLE). Long-term video EEGs were retrospectively reviewed in 21 patients, 7 men and 14 women aged 13 to 67 years, diagnosed as mTLE with MRI lesions in the mesial temporal structures (hippocampal sclerosis in 20 cases, amygdala hypertrophy in 1 case). Seventy-seven partial seizures without secondary generalization were extracted. Peri-ictal HR change was compared between 29 right seizures (9 patients) and 48 left seizures (12 patients). HR abruptly increased in all 29 right seizures and 42 of 48 left seizures. Onset time of HR increase in relation to ictal EEG onset was significantly earlier in right seizures than in left seizures (mean ± SD, -11.5 ± 14.8 vs 9.2 ± 21.7 seconds; p < 0.0001). Time of maximum HR was also significantly earlier in right seizures than in left seizures (36.0 ± 18.1 vs 58.0 ± 28.7 seconds; p < 0.0001). Maximum HR changes from baseline showed no significant difference between right and left seizures (47.5 ± 19.1 vs 40.8 ± 20.0/min). Significantly earlier tachycardia in right than left mTLE seizures supports previous hypotheses that the right cerebral hemisphere is dominant in the sympathetic network. No HR change, or delayed tachycardia possibly due to seizure propagation to the right hemisphere, may be a useful lateralizing sign of left mTLE seizures. © 2014 American Academy of Neurology.

  12. Mechanism of paroxysmal supraventricular tachycardia with ventriculoatrial conduction block.

    PubMed

    Issa, Ziad F

    2009-09-01

    Supraventricular tachycardia (SVT) with ventriculoatrial (VA) block. We report the case of a 25-year-old patient with paroxysmal SVT and intermittent VA block. Atrioventricular nodal re-entrant tachycardia with upper common pathway block and orthodromic nodoventricular or nodofascicular re-entrant tachycardia was considered in the differential diagnosis. Diagnostic characteristics were most compatible with non-re-entrant junctional tachycardia. The arrhythmia was cured by ablation at the right atrial posterior septum.

  13. Adolescent obesity adversely affects blood pressure and resting heart rate.

    PubMed

    Baba, Reizo; Koketsu, Masaaki; Nagashima, Masami; Inasaka, Hiroshi; Yoshinaga, Masao; Yokota, Mitsuhiro

    2007-05-01

    Obesity is associated with hypertension (HT) and high resting heart rate (HR), as well as metabolic disturbances. However, little is known about how strongly these hemodynamic abnormalities are associated with the degree of obesity in adolescents. Height, body weight, resting HR, and systolic and diastolic blood pressures were measured in 20,165 male and 19,683 female high-school students. Adiposity levels were classified into 6 groups by body mass index: group 1 (<20th percentile), group 2 (20th-39.9th percentile), group 3 (40th-59.9th percentile), group 4 (60th-79.9th percentile), group 5 (80th-98.9th percentile), and group 6 (> or =99th percentile). Systolic and diastolic hypertensions were defined as > or =140 mmHg and > or =85 mmHg, respectively. Resting tachycardia was defined as the corresponding 95th percentile or greater. Resting HR and systolic and diastolic blood pressures increased with adiposity level in both sexes (p<0.0001). Both systolic HT and diastolic HT were associated with high resting HR, and the clustering of these unfavorable conditions increased with the degree of obesity. Hemodynamic abnormalities, such as HT and a high resting HR, are closely associated with adolescent obesity and are probably explained by impaired autonomic nerve function.

  14. Reduced intrinsic heart rate is associated with reduced arrhythmic susceptibility in guinea-pig heart.

    PubMed

    Osadchii, Oleg E

    2014-12-01

    In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.

  15. Heart rate profile during exercise in patients with early repolarization.

    PubMed

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P < 0.05). The lower heart rate increment (< 106 beats/min) and heart rate decrement (< 95 beats/min) were significantly associated with the presence of early repolarization. After adjustment for age and sex, the multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P < 0.001) for the lower heart rate increment and heart rate decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  16. Long‐term Cardiovascular Risks Associated With an Elevated Heart Rate: The Framingham Heart Study

    PubMed Central

    Ho, Jennifer E.; Larson, Martin G.; Ghorbani, Anahita; Cheng, Susan; Coglianese, Erin E.; Vasan, Ramachandran S.; Wang, Thomas J.

    2014-01-01

    Background Higher heart rate has been associated with an adverse prognosis, but most prior studies focused on individuals with known cardiovascular disease or examined a limited number of outcomes. We sought to examine the association of baseline heart rate with both fatal and nonfatal outcomes during 2 decades of follow‐up. Methods and Results Our study included 4058 Framingham Heart Study participants (mean age 55 years, 56% women). Cox models were performed with multivariable adjustment for clinical risk factors and physical activity. A total of 708 participants developed incident cardiovascular disease (303 heart failure, 343 coronary heart disease, and 216 stroke events), 48 received a permanent pacemaker, and 1186 died. Baseline heart rate was associated with incident cardiovascular disease (hazard ratio [HR] 1.15 per 1 SD [11 bpm] increase in heart rate, 95% CI 1.07 to 1.24, P=0.0002), particularly heart failure (HR 1.32, 95% CI 1.18 to 1.48, P<0.0001). Higher heart rate was also associated with higher all‐cause (HR 1.17, 95% CI 1.11 to 1.24, P<0.0001) and cardiovascular mortality (HR 1.18, 95% CI 1.04 to 1.33, P=0.01). Spline analyses did not suggest a lower threshold beyond which the benefit of a lower heart rate abated or increased. In contrast, individuals with a higher heart rate had a lower risk of requiring permanent pacemaker placement (HR 0.55, 95% CI 0.38 to 0.79, P=0.001). Conclusions Individuals with a higher heart rate are at elevated long‐term risk for cardiovascular events, in particular, heart failure, and all‐cause death. On the other hand, a higher heart rate is associated with a lower risk of future permanent pacemaker implantation. PMID:24811610

  17. Surgery for ventricular tachycardia in patients undergoing surgical ventricular restoration: the Karolinska approach.

    PubMed

    Sartipy, Ulrik; Albåge, Anders; Insulander, Per; Lindblom, Dan

    2007-09-01

    This article presents a review on the efficacy of surgical ventricular restoration and direct surgery for ventricular tachycardia in patients with left ventricular aneurysm or dilated ischemic cardiomyopathy. The procedure includes a non-electrophysiologically guided subtotal endocardiectomy and cryoablation in addition to endoventricular patch plasty of the left ventricle. Coronary artery bypass surgery and mitral valve repair are performed concomitantly as needed. In our experience, this procedure yielded a 90% success rate in terms of freedom from spontaneous ventricular tachycardia, with an early mortality rate of 3.8%. A practical guide to the pre- and postoperative management of these patients is provided.

  18. Role of ivabradine and heart rate lowering in chronic heart failure: guideline update.

    PubMed

    Chow, Sheryl L; Page, Robert Lee; Depre, Christophe

    2018-06-14

    This review summarizes the current management of heart failure (HF) in patients with reduced ejection fraction and the potential role of heart rate lowering agents in select populations, as recommended in the updated guidelines. Areas covered: PubMed was searched for studies that evaluated the role of heart rate lowering or ivabradine in HF management. Expert commentary: Targeting heart rate may offer benefit when added to renin-angiotensin aldosterone antagonists, and beta-blockers. Ivabradine is a heart rate lowering agent that acts on the funny current (I f ) in the sinoatrial node, thereby reducing heart rate without directly affecting cardiac contraction and relaxation. Clinical data from a phase 3 trial demonstrated that ivabradine reduced the composite endpoint of cardiovascular death or hospital admission for worsening systolic HF, while maintaining an acceptable safety profile in patients receiving standard of care therapy. These data, in addition to more recently published guidelines, suggest ivabradine as a promising new treatment option for lowering heart rate after optimizing standard therapy in select patients with chronic HF.

  19. A protocol to study ex vivo mouse working heart at human-like heart rate.

    PubMed

    Feng, Han-Zhong; Jin, Jian-Ping

    2018-01-01

    Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Autonomic contribution to the blood pressure and heart rate variability changes in early experimental hyperthyroidism.

    PubMed

    Safa-Tisseront, V; Ponchon, P; Laude, D; Elghozi, J L

    1998-12-01

    To study the interaction between autonomic nervous activity and thyroid hormones in the control of heart rate (HR) and blood pressure (BP). Thyrotoxicosis was produced by injections of L-thyroxine (0.5 mg/kg/day for five days). Blockers were atropine (0.5 mg/kg), atenolol (1 mg/kg) or prazosin (1 mg/kg). Eight animals were studied in each group. Spectral analyses was performed using continuous BP time series obtained in conscious rats. Thyroxine treatment was sufficient to induce a significant degree of tachycardia (423+/-6 vs 353+/-4 bpm, P < 0.001, unpaired Student's t test), systolic BP elevation (142+/-3 vs 127+/-2 mmHg, P < 0.001) and cardiac hypertrophy (1.165+/-0.017 vs 1.006+/-0.012 g, P < 0.001). The intrinsic HR was markedly increased after treatment with thyroxine (497+/-16 vs 373+/-10 bpm, P < 0.05). Vagal tone was positively linearly related to intrinsic HR (r = 0.84, P< 0.01). Atenolol neither modified HR nor BP variability in rats with hyperthyroidism. The thyrotoxicosis was associated with a reduction of the 0.4 Hz component of BP variability (modulus 1.10+/-0.07 vs 1.41+/-0.06 mmHg, P < 0.01). Prazosin was without effect on this 0.4 Hz component in hyperthyroid animals. These data show a functional diminution of the vascular and cardiac sympathetic tone in early experimental hyperthyroidism. The marked rise in the intrinsic HR could be the main determinant of tachycardia. The BP elevation may reflexly induce vagal activation and sympathetic (vascular and cardiac) inhibition.

  1. Autonomic regulation of the heart during digestion and aerobic swimming in the European sea bass (Dicentrarchus labrax).

    PubMed

    Iversen, Nina K; Dupont-Prinet, Aurélie; Findorf, Inge; McKenzie, David J; Wang, Tobias

    2010-08-01

    The autonomic regulation of the heart was studied in European sea bass (Dicentrarchus labrax) during digestion and aerobic exercise by measuring cardiac output (Q), heart rate (f(H)), stroke volume (V(s)) and oxygen consumption (MO(2)) before and after pharmacological blockade by intraperitoneal injections of atropine and propranolol. The significant rise in MO(2) (134+/-14 to 174+/-14 mg kg(-)(1)h(-)(1)) 6h after feeding (3% body mass) caused a significant tachycardia (47.7+/-10.9 to 72.6+/-7.2 beats min(-)(1)), but only a small elevation of Q. MO(2) of fasting fish increased progressively with swimming speed (0.7-2.1BLs(-)(1)) causing a significant tachycardia (43+/-6 to 61+/-4 mL min(-)(1)kg(-)(1)) and increased Q but V(s) did not change. Inactive fish were characterized by a high vagal tone (98.3+/-21.7%), and the tachycardia during digestion and exercise was exclusively due to a reduction of vagal tone, while the adrenergic tone remained low during all conditions. Intrinsic f(H), revealed after double autonomic blockade, was not affected by digestion (71+/-4 and 70+/-6 min(-)(1), respectively), indicating that non-adrenergic, non-cholinergic (NANC) factors do not contribute to the tachycardia during digestion in sea bass. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. Optimization of pharmacotherapy in chronic heart failure: is heart rate adequately addressed?

    PubMed

    Franke, Jennifer; Wolter, Jan Sebastian; Meme, Lillian; Keppler, Jeannette; Tschierschke, Ramon; Katus, Hugo A; Zugck, Christian

    2013-01-01

    The aim of the study is to evaluate the use of beta-blockers in chronic heart failure (CHF) and the extent of heart rate reduction achieved in clinical practice and to determine differences in outcome of patients who fulfilled select inclusion criteria of the SHIFT study according to resting heart rate modulated by beta-blocker therapy. We evaluated an all-comer population of our dedicated CHF outpatient clinic between 2006 and 2010. For inclusion, individually optimized doses of guideline-recommended pharmacotherapy including beta-blockers had to be maintained for at least 3 months and routine follow-up performed at our outpatient CHF-clinic thereafter. Treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate were assessed. The outcome of patients who fulfilled select inclusion criteria of the SHIFT study (left-ventricular ejection fraction (LVEF) ≤35 %, sinus rhythm, NYHA II-IV) and were followed-up for at least 1 year was stratified according to resting heart rates: ≥75 versus <75 bpm and ≥70 versus <70 bpm. The composite primary endpoint was defined as all-cause death or hospital admission for worsening heart failure during 12-month follow-up. In total, 3,181 patients were assessed in regard to treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate. Of the overall studied population, 443 patients fulfilled all inclusion criteria and entered outcome analysis. Median observation time of survivors was 27.5 months with 1,039.7 observation-years in total. Up-titration to at least half the evidence-based target dose of beta-blockers was achieved in 69 % and full up-titration in 29 % of these patients. Patients with increased heart rates were younger, more often male, exhibited a higher NYHA functional class and lower LVEF. The primary endpoint occurred in 21 % of patients in the ≥70 bpm group versus 9 % of patients in the group with heart rates <70

  3. Fetal heart rate monitoring.

    PubMed

    Nageotte, Michael P

    2015-06-01

    Electronic fetal heart rate monitoring is a widely utilized means of assessment of fetal status during labor. Whereas little evidence exists regarding efficacy, this modality continues to be used extensively in every modern labor and delivery unit in developed countries. It is of importance that all providers of health care to the woman in labor and her newborn have a clear understanding of the basic pathophysiology of fetal heart rate monitoring and an appreciation for labor course and concerns as they arise in order to optimize outcomes and patient safety. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Symbolic dynamics for arrhythmia identification from heart variability of rats with cardiac failures

    NASA Astrophysics Data System (ADS)

    Letellier, C.; Roulin, E.; Loriot, S.; Morin, J.-P.; Dionnet, F.

    2004-12-01

    Heart rate variability of rats is investigated using concepts from the nonlinear dynamical system theory. Among the important techniques offered, symbolic dynamics is very appealing by its power to investigate patterns which can be repeated in a time series. The present analysis was performed in six control rats and six chronic cardiac insufficient rats (myocardial infarction due to left descendent coronary artery ligation). Rats are left in clean atmosphere or exposed to atmosphere containing diluted engine emission pollutants. The evolution of the heart rate variability is then investigated with a three element symbolic dynamics which allows to distinguish extrasystoles from tachycardia or bradycardia using the symbol sequences.

  5. An unusual tachycardia.

    PubMed

    Hanon, Sam; Shapiro, Michael; Schweitzer, Paul

    2004-07-01

    The following article presents an unusual case of atrial tachycardia, initially misdiagnosed due to a lack of clear P waves. The diagnosis was eventually confirmed using the atrial electrogram from the patient's pacemaker.

  6. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    PubMed

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P < .001, R 2 = .67, SEE = 2.78). HRR after a standardized warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  7. Inhibition of the reverse mode of the Na+/Ca2+ exchange by KB-R7943 augments arrhythmogenicity in the canine heart during rapid heart rates.

    PubMed

    Shinada, Takuro; Hirayama, Yoshiyuki; Maruyama, Mitsunori; Ohara, Toshihiko; Yashima, Masaaki; Kobayashi, Yoshinori; Atarashi, Hirotsugu; Takano, Teruo

    2005-07-01

    To test the hypothesis that the reverse mode of the Na+/Ca2+ exchange augmented by a rapid heart rate has an antiarrhythmic effect by shortening the action potential duration, we examined the effects of KB-R7943 (2-[2-[4-(4-nitrobenzyloxy)phenyl]ethyl] isothiourea methanesulfonate), a selective inhibitor of the reverse mode of the Na+/Ca2+ exchange, to attenuate this effect. We recorded the electrocardiogram, monophasic action potential (MAP), and left ventricular pressure in canine beating hearts. In comparison to the control, KB-R7943 significantly increased the QTc value and MAP duration. MAP alternans and left ventricular pressure alternans were observed after changing the cycle length to 300 milliseconds in the control studies. KB-R7943 magnified both types of alternans and produced spatially discordant alternans between right and left ventricles. Early after-depolarizations and nonsustained ventricular tachycardia occurred in the presence of KB-R7943. Our data suggest that the reverse mode of the Na+/Ca2+ exchange may contribute to suppression of arrhythmias by abbreviating action potential duration under pathophysiological conditions. This conclusion is based on further confirmation by future studies of the specificity of KB-R7943 for block of the reverse mode of the Na+/Ca2+ exchange.

  8. Differentiation of ventricular and supraventricular tachycardias based on the analysis of the first postpacing interval after sequential anti-tachycardia pacing in implantable cardioverter-defibrillator patients.

    PubMed

    Arenal, Angel; Ortiz, Mercedes; Peinado, Rafael; Merino, Jose L; Quesada, Aurelio; Atienza, Felipe; Alberola, Arcadio García; Ormaetxe, Jose; Castellanos, Eduardo; Rodriguez, Juan C; Pérez, Nicasio; García, Javier; Boluda, Luis; del Prado, Mario; Artés, Antonio

    2007-03-01

    Current discrimination algorithms do not completely avoid inappropriate tachycardia detection. This study analyzes the discrimination capability of the changes of the first postpacing interval (FPPI) after successive bursts of anti-tachycardia pacing (ATP) trains in implantable cardioverter-defibrillator (ICD)-recorded tachycardias. We included 50 ICD patients in this prospective study. We hypothesized that the FPPI variability (FPPIV) when comparing bursts with different numbers of beats would be shorter in ventricular tachycardias (VTs) compared with supraventricular tachycardias (SVTs). The ATP (5-10 pulses, 91% of tachycardia cycle length) was programmed for tachycardias >240 ms. Anti-tachycardia pacing was delivered during 37 sinus tachycardias (STs) in an exercise test, 96 induced VTs in an electrophysiological study, and 198 spontaneous episodes (144 VTs and 54 SVTs). The FPPI remained stable after all ATP bursts in VT but changed continuously in SVT; when comparing bursts of 5 and 10 pulses, the FPPIV was shorter in VT (34 +/- 65 vs.138 +/- 69, P<.0001, in all T and 12 +/- 20 vs. 138 +/- 69, P<.0001, in T>or=320 ms) than in SVT. In T>or=320 ms an FPPIVtachycardia pacing terminated 66% of induced VTs, 60% of spontaneous VTs, and 20% of spontaneous SVTs and induced no VT during spontaneous or exercise induced SVT. Five induced and two spontaneous VT episodes were accelerated. Analysis of FPPIV after ATP discriminates ICD-detected T. Successive bursts (of ATP) trains at 91% of tachycardia cycle length are safe, despite being delivered before rhythm classification.

  9. Heart Rates of Elite Synchronized Swimmers.

    ERIC Educational Resources Information Center

    Gemma, Karen Erickson; Wells, Christine L.

    1987-01-01

    Heart rates were recorded by radiotelemetry in ten elite and national-class synchronized swimmers as they performed competitive figures of high degrees of difficulty. The focus was on changes in heart rates and electrocardiogram patterns for each body position, especially those requiring facial immersion and breath-holding. (Author/MT)

  10. Long-term outcomes of remote magnetic navigation for ablation of supraventricular tachycardias.

    PubMed

    Kim, Sung-Hwan; Oh, Yong-Seog; Kim, Dong-Hwi; Choi, Ik Jun; Kim, Tae-Seok; Shin, Woo-Seung; Kim, Ji-Hoon; Jang, Sung-Won; Lee, Man Young; Rho, Tai-Ho

    2015-08-01

    Little is known about the long-term outcomes of catheter ablation of supraventricular tachycardia (SVT) using remote magnetic navigation system (RMN). One hundred twenty patients underwent catheter ablation of SVTs with RMN (Niobe, Stereotaxis, USA): atrioventricular nodal re-entrant tachycardia (AVNRT; n = 59), atrioventricular re-entrant tachycardia (AVRT; n = 45), and focal atrial tachycardia (AT, n = 16). The outcome of AVRT with right free wall accessory pathway was compared with those of a group of 26 consecutive patients undergoing manual ablation. Mean follow-up period was 2.2 ± 1.4 years. Overall arrhythmia-free survival was 86%; AVRT (77%), AVNRT (96%), and focal AT (71%). After the learning period (initial 50 cases), procedural outcomes had improved for AVRT and AVNRT (91% in overall group, 90% in AVRT group, 100% in AVNRT group, and 68% in focal AT group). The recurrence-free rate was higher for the free wall accessory pathways than those of the other sites (92 vs. 73%, log-rank P = 0.06). Furthermore, when it is confined for the right free wall accessory pathway, RMN showed excellent long-term outcome (7/7, 100 %) compared to the results of manual approach (18/26, 69.2%, log-rank P = 0.07). RMN showed favorable long-term outcomes for the ablation of SVT. In our experience, RMN-guided ablation may be associated with a higher success rate as compared to manual ablation when treating right-sided free wall pathways.

  11. Genome-wide association studies and resting heart rate.

    PubMed

    Kilpeläinen, Tuomas O

    Genome-wide association studies (GWASs) have revolutionized the search for genetic variants regulating resting heart rate. In the last 10years, GWASs have led to the identification of at least 21 novel heart rate loci. These discoveries have provided valuable insights into the mechanisms and pathways that regulate heart rate and link heart rate to cardiovascular morbidity and mortality. GWASs capture majority of genetic variation in a population sample by utilizing high-throughput genotyping chips measuring genotypes for up to several millions of SNPs across the genome in thousands of individuals. This allows the identification of the strongest heart rate associated signals at genome-wide level. While GWASs provide robust statistical evidence of the association of a given genetic locus with heart rate, they are only the starting point for detailed follow-up studies to locate the causal variants and genes and gain further insights into the biological mechanisms underlying the observed associations. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Heart rate at first postdischarge visit and outcomes in patients with heart failure.

    PubMed

    Kim, Tae-Hun; Kim, Hyungseop; Kim, In-Cheol; Yoon, Hyuck-Jun; Park, Hyoung-Seob; Cho, Yun-Kyeong; Nam, Chang-Wook; Han, Seongwook; Hur, Seung-Ho; Kim, Yoon-Nyun

    2018-07-01

    Heart rate control is important to prevent adverse outcomes in patients with heart failure (HF). However, postdischarge activity may worsen heart rate control, resulting in readmission. This study aimed to explore the implications of the heart rate differences between discharge and the first outpatient visit (D-O diff). We retrospectively identified 458 patients (male: 46%; mean age: 72 years) discharged after HF. The heart rates at admission, discharge and first outpatient visit were analysed. The primary outcome was a composite of cardiovascular (CV) death and readmission of non-fatal myocardial infarction (MI), non-fatal stroke or non-fatal HF over a mean follow-up of 16 months. During follow-up, the clinical outcomes were noted in 223 patients (49%): HF, 199; stroke, 9; MI, 6; CV death, 9. The heart rate at the first outpatient visit (r=-0.311, P<0.001) and D-O diff (r=0.416, P<0.001) showed a better correlation with the time-to-clinical event than the heart rate at admission or discharge. The events group displayed a pronounced heart rate increase (13 beats/min) from discharge to the first outpatient visit compared with the event-free group (a decrease of 2 beats/min). A decrease less than -15 in the D-O diff showed a 4.5-fold risk of clinical outcomes during follow-up (P<0.001). A decreased D-O diff was related to the adverse outcomes of HF. The failure of heart rate control within more than 15 beats/min at the first outpatient visit was an independent factor for CV events. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Heart Rate During Sleep: Implications for Monitoring Training Status

    PubMed Central

    Waldeck, Miriam R.; Lambert, Michael I.

    2003-01-01

    Resting heart rate has sometimes been used as a marker of training status. It is reasonable to assume that the relationship between heart rate and training status should be more evident during sleep when extraneous factors that may influence heart rate are reduced. Therefore the aim of the study was to assess the repeatability of monitoring heart rate during sleep when training status remained unchanged, to determine if this measurement had sufficient precision to be used as a marker of training status. The heart rate of ten female subjects was monitored for 24 hours on three occasions over three weeks whilst training status remained unchanged. Average, minimum and maximum heart rate during sleep was calculated. The average heart rate of the group during sleep was similar on each of the three tests (65 ± 9, 63 ± 6 and 67 ± 7 beats·min-1 respectively). The range in minimum heart rate variation during sleep for all subjects over the three testing sessions was from 0 to 10 beats·min-1 (mean = 5 ± 3 beats·min-1) and for maximum heart rate variation was 2 to 31 beats·min-1 (mean = 13 ± 9 beats·min-1). In summary it was found that on an individual basis the minimum heart rate during sleep varied by about 8 beats·min-1. This amount of intrinsic day-to-day variation needs to be considered when changes in heart rate that may occur with changes in training status are interpreted. PMID:24688273

  14. Heart Rate Dynamics During A Treadmill Cardiopulmonary Exercise Test in Optimized Beta-Blocked Heart Failure Patients

    PubMed Central

    Carvalho, Vitor Oliveira; Guimarães, Guilherme Veiga; Ciolac, Emmanuel Gomes; Bocchi, Edimar Alcides

    2008-01-01

    BACKGROUND Calculating the maximum heart rate for age is one method to characterize the maximum effort of an individual. Although this method is commonly used, little is known about heart rate dynamics in optimized beta-blocked heart failure patients. AIM The aim of this study was to evaluate heart rate dynamics (basal, peak and % heart rate increase) in optimized beta-blocked heart failure patients compared to sedentary, normal individuals (controls) during a treadmill cardiopulmonary exercise test. METHODS Twenty-five heart failure patients (49±11 years, 76% male), with an average LVEF of 30±7%, and fourteen controls were included in the study. Patients with atrial fibrillation, a pacemaker or noncardiovascular functional limitations or whose drug therapy was not optimized were excluded. Optimization was considered to be 50 mg/day or more of carvedilol, with a basal heart rate between 50 to 60 bpm that was maintained for 3 months. RESULTS Basal heart rate was lower in heart failure patients (57±3 bpm) compared to controls (89±14 bpm; p<0.0001). Similarly, the peak heart rate (% maximum predicted for age) was lower in HF patients (65.4±11.1%) compared to controls (98.6±2.2; p<0.0001). Maximum respiratory exchange ratio did not differ between the groups (1.2±0.5 for controls and 1.15±1 for heart failure patients; p=0.42). All controls reached the maximum heart rate for their age, while no patients in the heart failure group reached the maximum. Moreover, the % increase of heart rate from rest to peak exercise between heart failure (48±9%) and control (53±8%) was not different (p=0.157). CONCLUSION No patient in the heart failure group reached the maximum heart rate for their age during a treadmill cardiopulmonary exercise test, despite the fact that the percentage increase of heart rate was similar to sedentary normal subjects. A heart rate increase in optimized beta-blocked heart failure patients during cardiopulmonary exercise test over 65% of the

  15. Tachycardia, reduced vagal capacity, and age-dependent ventricular dysfunction arising from diminished expression of the presynaptic choline transporter.

    PubMed

    English, Brett A; Appalsamy, Martin; Diedrich, Andre; Ruggiero, Alicia M; Lund, David; Wright, Jane; Keller, Nancy R; Louderback, Katherine M; Robertson, David; Blakely, Randy D

    2010-09-01

    Healthy cardiovascular function relies on a balanced and responsive integration of noradrenergic and cholinergic innervation of the heart. High-affinity choline uptake by cholinergic terminals is pivotal for efficient ACh production and release. To date, the cardiovascular impact of diminished choline transporter (CHT) expression has not been directly examined, largely due to the transporter's inaccessibility in vivo. Here, we describe findings from cardiovascular experiments using transgenic mice that bear a CHT genetic deficiency. Whereas CHT knockout (CHT(-/-)) mice exhibit early postnatal lethality, CHT heterozygous (CHT(+/-)) mice survive, grow, and reproduce normally and exhibit normal spontaneous behaviors. However, the CHT(+/-) mouse heart displays significantly reduced levels of high-affinity choline uptake accompanied by significantly reduced levels of ACh. Telemeterized recordings of cardiovascular function in these mice revealed tachycardia and hypertension at rest. After treadmill exercise, CHT(+/-) mice exhibited slower heart rate recovery, consistent with a diminished cholinergic reserve, a contention validated through direct vagal nerve stimulation. Echocardiographic and histological experiments revealed an age-dependent decrease in fractional shortening, increased left ventricular dimensions, and increased ventricular fibrosis, consistent with ventricular dysfunction. These cardiovascular phenotypes of CHT(+/-) mice encourage an evaluation of humans bearing reduced CHT expression for their resiliency in maintaining proper heart function as well as risk for cardiovascular disease.

  16. Role of the autonomic nervous system in the control of heart rate and blood pressure in the defence reaction in conscious dogs.

    PubMed

    Federici, A; Rizzo, A; Cevese, A

    1985-04-01

    The present study was performed on conscious, chronically instrumented dogs, which underwent selective blockade of sympathetic adrenergic and vagal outflows. Excitements were performed on these animals in normal states (N), after chronic treatment with guanethidine, for sympathetic blockade (SB), after cold vagal blockade (VB), and after combined sympathetic and vagal blockade (SB + VB). Heart rate and arterial blood pressure were monitored in all the experiments, while a group of dogs was also tested with an electromagnetic flowmeter on the superior mesenteric artery. The role of the sympathetic and parasympathetic controls in the defence reaction was assumed from comparison of experiments performed in the presence or in the absence of each (or both) autonomic component(s). In the SB + VB condition, excitement was followed by sudden hypotension, without changes in heart rate. In VB experiments, a brief and transient hypotension appeared, followed by gradually developed hypertension, while heart rate progressively rose in about 5 s; there was no sudden increase in mesenteric vascular resistance, which contrasted with the very marked reaction in N experiments. Under vagal control alone (SB), the stimulus elicited prompt tachycardia and hypertension, followed by a period of moderately reduced blood pressure. We conclude that, while the defence reaction leads to a sudden fall of arterial blood pressure, in the absence of compensatory mechanisms, both branches of the autonomic nervous system play a protective role against hypotension. In addition, the modulation of the vagal outflow, leading to sudden changes in the heart performance, seems to be responsible for the initiation of the overall haemodynamic adjustments following excitements. The possibility that withdrawal of the parasympathetic outflow to the heart may raise arterial blood pressure was verified in a special experiment in which artificial vagal stimulation in a conscious (vagal blocked) dog, was turned

  17. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    PubMed

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  18. Comparison of cryoablation with 3D mapping versus conventional mapping for the treatment of atrioventricular re-entrant tachycardia and right-sided paraseptal accessory pathways.

    PubMed

    Russo, Mario S; Drago, Fabrizio; Silvetti, Massimo S; Righi, Daniela; Di Mambro, Corrado; Placidi, Silvia; Prosperi, Monica; Ciani, Michele; Naso Onofrio, Maria T; Cannatà, Vittorio

    2016-06-01

    Aim Transcatheter cryoablation is a well-established technique for the treatment of atrioventricular nodal re-entry tachycardia and atrioventricular re-entry tachycardia in children. Fluoroscopy or three-dimensional mapping systems can be used to perform the ablation procedure. The aim of this study was to compare the success rate of cryoablation procedures for the treatment of right septal accessory pathways and atrioventricular nodal re-entry circuits in children using conventional or three-dimensional mapping and to evaluate whether three-dimensional mapping was associated with reduced patient radiation dose compared with traditional mapping. In 2013, 81 children underwent transcatheter cryoablation at our institution, using conventional mapping in 41 children - 32 atrioventricular nodal re-entry tachycardia and nine atrioventricular re-entry tachycardia - and three-dimensional mapping in 40 children - 24 atrioventricular nodal re-entry tachycardia and 16 atrioventricular re-entry tachycardia. Using conventional mapping, the overall success rate was 78.1 and 66.7% in patients with atrioventricular nodal re-entry tachycardia or atrioventricular re-entry tachycardia, respectively. Using three-dimensional mapping, the overall success rate was 91.6 and 75%, respectively (p=ns). The use of three-dimensional mapping was associated with a reduction in cumulative air kerma and cumulative air kerma-area product of 76.4 and 67.3%, respectively (p<0.05). The use of three-dimensional mapping compared with the conventional fluoroscopy-guided method for cryoablation of right septal accessory pathways and atrioventricular nodal re-entry circuits in children was associated with a significant reduction in patient radiation dose without an increase in success rate.

  19. Dissociation of heart rate variability and heart rate recovery in well-trained athletes.

    PubMed

    Lee, C Matthew; Mendoza, Albert

    2012-07-01

    The purpose of this investigation was to examine the relationships between aerobic fitness, volume of physical activity (PA), heart rate variability (HRV), and heart rate recovery (HRR) in a group of well-trained endurance athletes. Nineteen endurance athletes participated in this study and had aerobic capacities that placed them above the 99th percentile based on normative values (VO(2max): 67.1 ± 2 ml kg(-1) min(-1)). HRV was obtained via an EKG collected during supine rest and reported as high-frequency (HF), low-frequency (LF), and total power (TP). Natural log (ln) transformation was applied when variables violated assumptions of normality. HRR recovery was reported as the reduction in heart rate from peak exercise to the heart rate 1 min after cessation of exercise and PA was estimated from a questionnaire. HRR was significantly correlated with PA and VO(2max) (r = 0.67, P = 0.003 and 0.51, P = 0.039, respectively), but not with any index of HRV. Age was significantly correlated with lnHF (r = -0.49, P = 0.033), lnLF/lnHF (r = 0.48, P = 0.037), and normalized units (NU) of LF (r = 0.47, P = 0.042) and HF (r = -0.47, P = 0.042). Stepwise regression revealed that the strongest predictor of HRR was PA (R (2) = 0.45) and that VO(2max) did not add significant predictive value to the model. The relationship between HRV and age is evident in well-trained endurance athletes, whereas the relationship between HRV and PA/aerobic fitness is not. The maintained relationship between HRR and PA/aerobic fitness suggests that HRR may be a better marker of fitness-related differences in autonomic control in this population.

  20. Heart Rate, Life Expectancy and the Cardiovascular System: Therapeutic Considerations.

    PubMed

    Boudoulas, Konstantinos Dean; Borer, Jeffrey S; Boudoulas, Harisios

    2015-01-01

    It has long been known that life span is inversely related to resting heart rate in most organisms. This association between heart rate and survival has been attributed to the metabolic rate, which is greater in smaller animals and is directly associated with heart rate. Studies have shown that heart rate is related to survival in apparently healthy individuals and in patients with different underlying cardiovascular diseases. A decrease in heart rate due to therapeutic interventions may result in an increase in survival. However, there are many factors regulating heart rate, and it is quite plausible that these may independently affect life expectancy. Nonetheless, a fast heart rate itself affects the cardiovascular system in multiple ways (it increases ventricular work, myocardial oxygen consumption, endothelial stress, aortic/arterial stiffness, decreases myocardial oxygen supply, other) which, in turn, may affect survival. In this brief review, the effects of heart rate on the heart, arterial system and survival will be discussed. © 2015 S. Karger AG, Basel.

  1. Right diaphragmatic paralysis following endocardial cryothermal ablation of inappropriate sinus tachycardia.

    PubMed

    Vatasescu, Radu; Shalganov, Tchavdar; Kardos, Attila; Jalabadze, Khatuna; Paprika, Dora; Gyorgy, Margit; Szili-Torok, Tamas

    2006-10-01

    Inappropriate sinus tachycardia (IST) is a rare disorder amenable to catheter ablation when refractory to medical therapy. Radiofrequency (RF) catheter modification/ablation of the sinus node (SN) is the usual approach, although it can be complicated by right phrenic nerve paralysis. We describe a patient with IST, who had symptomatic recurrences despite previous acutely successful RF SN modifications, including the use of electroanatomical mapping/navigation system. We decided to try transvenous cryothermal modification of the SN. We used 2 min applications at -85 degrees C at sites of the earliest atrial activation guided by activation mapping during isoprenaline infusion. Every application was preceded by high output stimulation to reveal phrenic nerve proximity. During the last application, heart rate slowly and persistently fell below 85 bpm despite isoprenaline infusion, but right diaphragmatic paralysis developed. At 6 months follow-up, the patient was asymptomatic and the diaphragmatic paralysis had partially resolved. This is the first report, we believe, of successful SN modification for IST by endocardial cryoablation, although this case also demonstrates the considerable risk of right phrenic nerve paralysis even with this ablation energy.

  2. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  3. Yield of the RYR2 Genetic Test in Suspected Catecholaminergic Polymorphic Ventricular Tachycardia and Implications for Test Interpretation.

    PubMed

    Kapplinger, Jamie D; Pundi, Krishna N; Larson, Nicholas B; Callis, Thomas E; Tester, David J; Bikker, Hennie; Wilde, Arthur A M; Ackerman, Michael J

    2018-02-01

    Pathogenic RYR2 variants account for ≈60% of clinically definite cases of catecholaminergic polymorphic ventricular tachycardia. However, the rate of rare benign RYR2 variants identified in the general population remains a challenge for genetic test interpretation. Therefore, we examined the results of the RYR2 genetic test among patients referred for commercial genetic testing and examined factors impacting variant interpretability. Frequency and location comparisons were made for RYR2 variants identified among 1355 total patients of varying clinical certainty and 60 706 Exome Aggregation Consortium controls. The impact of the clinical phenotype on the yield of RYR2 variants was examined. Six in silico tools were assessed using patient- and control-derived variants. A total of 18.2% (218/1200) of patients referred for commercial testing hosted rare RYR2 variants, statistically less than the 59% (46/78) yield among clinically definite cases, resulting in a much higher potential genetic false discovery rate among referrals considering the 3.2% background rate of rare, benign RYR2 variants. Exclusion of clearly putative pathogenic variants further complicates the interpretation of the next novel RYR2 variant. Exonic/topologic analyses revealed overrepresentation of patient variants in exons covering only one third of the protein. In silico tools largely failed to show evidence toward enhancement of variant interpretation. Current expert recommendations have resulted in increased use of RYR2 genetic testing in patients with questionable clinical phenotypes. Using the largest to date catecholaminergic polymorphic ventricular tachycardia patient versus control comparison, this study highlights important variables in the interpretation of variants to overcome the 3.2% background rate that confounds RYR2 variant interpretation. © 2018 American Heart Association, Inc.

  4. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    PubMed Central

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669

  5. Cardiorespiratory functional assessment after pediatric heart transplantation.

    PubMed

    Pastore, E; Turchetta, A; Attias, L; Calzolari, A; Giordano, U; Squitieri, C; Parisi, F

    2001-12-01

    Limited data are available on the exercise capacity of young heart transplant recipients. The aim of this study was therefore to assess cardiorespiratory responses to exercise in this group of patients. Fourteen consecutive heart transplant recipients (six girls and eight boys, age-range 5-15 yr) and 14 healthy matched controls underwent a Bruce treadmill test to determine: duration of test; resting and maximum heart rates; maximum systolic blood pressure; peak oxygen consumption (VO2 peak); and cardiac output. Duration of test and heart rate increase were then compared with: time since transplantation, rejections per year, and immunosuppressive drugs received. The recipients also underwent the following lung function tests: forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). When compared with healthy controls, transplant recipients had tachycardia at rest (126 +/- 3.7 beats/min; p < 0.001); significantly reduced tolerance (9.3 +/- 0.4 min; p < 0.001), a maximum heart rate of 169 +/- 5.4 beats/min (p < 0.05); a cardiac output of 5.65 +/- 0.6 L/min (p < 0.05); and a lower heart-rate increase from rest to peak exercise (p < 0.001) but a similar VO2 peak. The heart-rate increase correlated significantly with time post-transplant (r = 0.55; p < 0.05), number of rejection episodes per year (r = - 0.63; p < 0.05), and number of immunosuppressive drugs (r = - 0.60; p < 0.05). The recipients had normal FVC and FEV1 values. After surgery, few heart transplant recipients undertake physical activity, possibly owing to over-protective parents and teachers and to a lack of suitable supervised facilities. The authors stress the importance of a cardiorespiratory functional evaluation for assessment of health status and to encourage recipients, if possible, to undertake regular physical activity.

  6. Inhalation of ultrafine carbon particles alters heart rate and heart rate variability in people with type 2 diabetes.

    PubMed

    Vora, Rathin; Zareba, Wojciech; Utell, Mark J; Pietropaoli, Anthony P; Chalupa, David; Little, Erika L; Oakes, David; Bausch, Jan; Wiltshire, Jelani; Frampton, Mark W

    2014-07-16

    Diabetes may confer an increased risk for the cardiovascular health effects of particulate air pollution, but few human clinical studies of air pollution have included people with diabetes. Ultrafine particles (UFP, ≤100 nm in diameter) have been hypothesized to be an important component of particulate air pollution with regard to cardiovascular health effects. 17 never-smoker subjects 30-60 years of age, with stable type 2 diabetes but otherwise healthy, inhaled either filtered air (0-10 particles/cm3) or elemental carbon UFP (~107 particles/cm3, ~50 ug/m3, count median diameter 32 nm) by mouthpiece, for 2 hours at rest, in a double-blind, randomized, crossover study design. A digital 12-lead electrocardiogram (ECG) was recorded continuously for 48 hours, beginning 1 hour prior to exposure. Analysis of 5-minute segments of the ECG during quiet rest showed reduced high-frequency heart rate variability with UFP relative to air exposure (p = 0.014), paralleled by non-significant reductions in time-domain heart rate variability parameters. In the analysis of longer durations of the ECG, we found that UFP exposure increased the heart rate relative to air exposure. During the 21- to 45-hour interval after exposure, the average heart rate increased approximately 8 beats per minute with UFP, compared to 5 beats per minute with air (p = 0.045). There were no UFP effects on cardiac rhythm or repolarization. Inhalation of elemental carbon ultrafine particles alters heart rate and heart rate variability in people with type 2 diabetes. Our findings suggest that effects may occur and persist hours after a single 2-hour exposure.

  7. [Analysis of Foetal Heart Rate Data using Complex Software: Comparison of Recurrence Plot of Foetal Heart Rate with the Course of Pregnancy -].

    PubMed

    Jörn, H; Morgenstern, B; Wassenberg, B; Rath, W

    2004-08-01

    Is it useful to further analyse foetal heart rate to improve the prediction of pregnancy complications? The analysis of the foetal heart rate is usually based on the variability of the heart rate, i. e. the more variable the heart rate presents - except a decrease - the better the condition of the foetus is. The same concept is applied in our own analysis which differs only in the presentation of the data. We analysed 25 non-stress-tests from unselected third trimester pregnancies using sophisticated software. The recurrence plot (RP) is able to rearrange data from foetal heart rate monitoring in order to make the heart rate variability visible. We developed criteria for a normal and an abnormal test result describing the structure of the diagram to predict an uneventful and a high-risk pregnancy, respectively. 11 out of 11 patients with uneventful course and outcome of pregnancy showed a coarse and blurred RP pattern. 12 out of 14 (86 %) patients developing either intrauterine growth retardation or preeclampsia and requiring caesarean section because of foetal heart rate abnormalities showed a fine and clear RP pattern. Our preliminary results show that it makes sense to further evaluate foetal heart rate variability in order to predict pregnancy complications. Computer programs including the algorithms needed (calculation of the recurrence plot) are not expensive and easy to handle. A widespread use of these programs represents the basis requirement for large controlled clinical trials.

  8. The mitochondrial uniporter controls fight or flight heart rate increases.

    PubMed

    Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E

    2015-01-20

    Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.

  9. Arduino-based noise robust online heart-rate detection.

    PubMed

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  10. Heart Rate and Reinforcement Sensitivity in ADHD

    ERIC Educational Resources Information Center

    Luman, Marjolein; Oosterlaan, Jaap; Hyde, Christopher; van Meel, Catharina S.; Sergeant, Joseph A.

    2007-01-01

    Background: Both theoretical and clinical accounts of attention-deficit/hyperactivity disorder (ADHD) implicate a dysfunctional reinforcement system. This study investigated heart rate parameters in response to feedback associated with reward and response cost in ADHD children and controls aged 8 to 12. Methods: Heart rate responses (HRRs)…

  11. Imaging cardiac activation sequence during ventricular tachycardia in a canine model of nonischemic heart failure.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Yu, Long; Zhou, Zhaoye; Killingsworth, Cheryl R; He, Bin

    2015-01-15

    Noninvasive cardiac activation imaging of ventricular tachycardia (VT) is important in the clinical diagnosis and treatment of arrhythmias in heart failure (HF) patients. This study investigated the ability of the three-dimensional cardiac electrical imaging (3DCEI) technique for characterizing the activation patterns of spontaneously occurring and norepinephrine (NE)-induced VTs in a newly developed arrhythmogenic canine model of nonischemic HF. HF was induced by aortic insufficiency followed by aortic constriction in three canines. Up to 128 body-surface ECGs were measured simultaneously with bipolar recordings from up to 232 intramural sites in a closed-chest condition. Data analysis was performed on the spontaneously occurring VTs (n=4) and the NE-induced nonsustained VTs (n=8) in HF canines. Both spontaneously occurring and NE-induced nonsustained VTs initiated by a focal mechanism primarily from the subendocardium, but occasionally from the subepicardium of left ventricle. Most focal initiation sites were located at apex, right ventricular outflow tract, and left lateral wall. The NE-induced VTs were longer, more rapid, and had more focal sites than the spontaneously occurring VTs. Good correlation was obtained between imaged activation sequence and direct measurements (averaged correlation coefficient of ∼0.70 over 135 VT beats). The reconstructed initiation sites were ∼10 mm from measured initiation sites, suggesting good localization in such a large animal model with cardiac size similar to a human. Both spontaneously occurring and NE-induced nonsustained VTs had focal initiation in this canine model of nonischemic HF. 3DCEI is feasible to image the activation sequence and help define arrhythmia mechanism of nonischemic HF-associated VTs. Copyright © 2015 the American Physiological Society.

  12. How heart rate variability affects emotion regulation brain networks.

    PubMed

    Mather, Mara; Thayer, Julian

    2018-02-01

    Individuals with high heart rate variability tend to have better emotional well-being than those with low heart rate variability, but the mechanisms of this association are not yet clear. In this paper, we propose the novel hypothesis that by inducing oscillatory activity in the brain, high amplitude oscillations in heart rate enhance functional connectivity in brain networks associated with emotion regulation. Recent studies using daily biofeedback sessions to increase the amplitude of heart rate oscillations suggest that high amplitude physiological oscillations have a causal impact on emotional well-being. Because blood flow timing helps determine brain network structure and function, slow oscillations in heart rate have the potential to strengthen brain network dynamics, especially in medial prefrontal regulatory regions that are particularly sensitive to physiological oscillations.

  13. Heart Rate Monitoring in Team Sports-A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription.

    PubMed

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To

  14. Heart Rate Monitoring in Team Sports—A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription

    PubMed Central

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics

  15. Association of heart rate at hospital discharge with mortality and hospitalizations in patients with heart failure.

    PubMed

    Habal, Marlena V; Liu, Peter P; Austin, Peter C; Ross, Heather J; Newton, Gary E; Wang, Xuesong; Tu, Jack V; Lee, Douglas S

    2014-01-01

    Heart failure (HF) is associated with a high burden of morbidity and mortality. Hospital discharge is an opportunity for identification of modifiable prognostic factors in the transition to chronic HF. We examined the association of discharge heart rate with 30-day and 1-year mortality and hospitalization outcomes in a cohort of 9097 patients with HF discharged from hospital. Discharge heart rate was categorized into predefined groups: 40 to 60 (n=1333), 61 to 70 (n=2170), 71 to 80 (n=2631), 81 to 90 (n=1700), and >90 bpm (n=1263). There was a significant increase in all-cause 30-day mortality with adjusted odds ratios of 1.59 (95% confidence interval [CI], 1.18-2.14; P=0.003) for discharge heart rates 81 to 90 bpm and 1.56 (95% CI, 1.13-2.16; P=0.007) for heart rates>90 bpm when compared with the reference group (heart rates, 61-70 bpm). Cardiovascular death risk at 30 days was also higher with adjusted odds ratio 1.59 (discharge heart rates, 81-90 bpm; 95% CI, 1.09-2.33; P=0.017) and 1.65 (discharge heart rates, >90 bpm; 95% CI, 1.09-2.48; P=0.017). One-year all-cause mortality (adjusted odds ratio, 1.41; 95% CI, 1.16-1.72; P<0.001) and cardiovascular death (adjusted odds ratio, 1.47; 95% CI, 1.12-1.92; P=0.005) were higher with discharge heart rates>90 bpm when compared with the reference group (heart rates, 40-60 bpm). Readmissions for HF (adjusted hazard ratio, 1.26; 95% CI, 1.04-1.54; P=0.021) and cardiovascular disease (adjusted hazard ratio, 1.29; 95% CI, 1.08-1.54; P=0.004) within 30 days were also higher with discharge heart rates>90 bpm. Higher discharge heart rates were associated with greater risk of all-cause and cardiovascular mortality≤1-year follow-up and an elevated risk of 30-day readmission for HF and cardiovascular disease.

  16. Tachycardia, reduced vagal capacity, and age-dependent ventricular dysfunction arising from diminished expression of the presynaptic choline transporter

    PubMed Central

    English, Brett A.; Appalsamy, Martin; Diedrich, Andre; Ruggiero, Alicia M.; Lund, David; Wright, Jane; Keller, Nancy R.; Louderback, Katherine M.; Robertson, David

    2010-01-01

    Healthy cardiovascular function relies on a balanced and responsive integration of noradrenergic and cholinergic innervation of the heart. High-affinity choline uptake by cholinergic terminals is pivotal for efficient ACh production and release. To date, the cardiovascular impact of diminished choline transporter (CHT) expression has not been directly examined, largely due to the transporter's inaccessibility in vivo. Here, we describe findings from cardiovascular experiments using transgenic mice that bear a CHT genetic deficiency. Whereas CHT knockout (CHT−/−) mice exhibit early postnatal lethality, CHT heterozygous (CHT+/−) mice survive, grow, and reproduce normally and exhibit normal spontaneous behaviors. However, the CHT+/− mouse heart displays significantly reduced levels of high-affinity choline uptake accompanied by significantly reduced levels of ACh. Telemeterized recordings of cardiovascular function in these mice revealed tachycardia and hypertension at rest. After treadmill exercise, CHT+/− mice exhibited slower heart rate recovery, consistent with a diminished cholinergic reserve, a contention validated through direct vagal nerve stimulation. Echocardiographic and histological experiments revealed an age-dependent decrease in fractional shortening, increased left ventricular dimensions, and increased ventricular fibrosis, consistent with ventricular dysfunction. These cardiovascular phenotypes of CHT+/− mice encourage an evaluation of humans bearing reduced CHT expression for their resiliency in maintaining proper heart function as well as risk for cardiovascular disease. PMID:20601463

  17. Heart rate measurement based on face video sequence

    NASA Astrophysics Data System (ADS)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  18. Mechanism-specific effects of adenosine on ventricular tachycardia.

    PubMed

    Lerman, Bruce B; Ip, James E; Shah, Bindi K; Thomas, George; Liu, Christopher F; Ciaccio, Edward J; Wit, Andrew L; Cheung, Jim W; Markowitz, Steven M

    2014-12-01

    There is no universally accepted method by which to diagnose clinical ventricular tachycardia (VT) due to cAMP-mediated triggered activity. Based on cellular and clinical data, adenosine termination of VT is thought to be consistent with a diagnosis of triggered activity. However, a major gap in evidence mitigates the validity of this proposal, namely, defining the specificity of adenosine response in well-delineated reentrant VT circuits. To this end, we systematically studied the effects of adenosine in a model of canine reentrant VT and in human reentrant VT, confirmed by 3-dimensional, pace- and substrate mapping. Adenosine (12 mg [IQR 12-24]) failed to terminate VT in 31 of 31 patients with reentrant VT due to structural heart disease, and had no effect on VT cycle length (age, 67 years [IQR 53-74]); ejection fraction, 35% [IQR 20-55]). In contrast, adenosine terminated VT in 45 of 50 (90%) patients with sustained focal right or left outflow tract tachycardia. The sensitivity of adenosine for identifying VT due to triggered activity was 90% (95% CI, 0.78-0.97) and its specificity was 100% (95% CI, 0.89-1.0). Additionally, reentrant circuits were mapped in the epicardial border zone of 4-day-old infarcts in mongrel dogs. Adenosine (300-400 μg/kg) did not terminate sustained VT or have any effect on VT cycle length. These data support the concept that adenosine's effects on ventricular myocardium are mechanism specific, such that termination of VT in response to adenosine is diagnostic of cAMP-mediated triggered activity. © 2014 Wiley Periodicals, Inc.

  19. A study of the 200-metre fast walk test as a possible new assessment tool to predict maximal heart rate and define target heart rate for exercise training of coronary heart disease patients.

    PubMed

    Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles

    2015-02-01

    To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.

  20. Ablation of post-surgical intra-atrial reentrant tachycardia. Predilection target sites and mapping approach.

    PubMed

    Anné, W; van Rensburg, H; Adams, J; Ector, H; Van de Werf, F; Heidbüchel, H

    2002-10-01

    Atrial arrhythmias are a frequent complication of atrial surgery. The location of these tachycardias is very diverse due to the individual difference in the original anatomy, surgical corrections, and effects of atrial fibrosis. Nevertheless some recurrent patterns are emerging. Forty-five patients underwent 51 ablation procedures between September 1995 and March 2001 using conventional mapping and temperature-controlled ablation. A duadecapolar catheter was swept from anterior to posterior in the right (and/or left) atrium, allowing for rapid mapping followed by entrainment confirmation. Twenty-eight patients had corrected congenital heart disease, 17 surgery for acquired heart disease. One hundred and sixteen arrhythmias were found, 86 circuits were targeted, 81 with success (94%). Despite the heterogeneous anatomy, the same targets were often encountered: the posterior isthmus between the inferior vena cava and the tricuspid ring (62%), the gap between the inferior vena cava and the atriotomy scar (49%), and the region around the atriopulmonary connection in Fontans (two out of four patients). After a mean follow-up of 24 months, 13 patients had a recurrent arrhythmia (29%) after their last procedure. There was a significant association between the number of circuits found during the initial procedure and the likelihood of recurrent arrhythmias. Knowledge of anatomical predilection sites and mapping the right (and/or left) atrium with a 'sweeping Halo technique' allow for effective ablation of most post-surgical atrial tachycardias. Severely damaged atria with multiple arrhythmias may require 'preventive' ablation of all recognizable channels.

  1. Six-minute walk test and heart rate variability: lack of association in advanced stages of heart failure.

    PubMed

    Woo, M A; Moser, D K; Stevenson, L W; Stevenson, W G

    1997-09-01

    The 6-minute walk and heart rate variability have been used to assess mortality risk in patients with heart failure, but their relationship to each other and their usefulness for predicting mortality at 1 year are unknown. To assess the relationships between the 6-minute walk test, heart rate variability, and 1-year mortality. A sample of 113 patients in advanced stages of heart failure (New York Heart Association Functional Class III-IV, left ventricular ejection < 0.25) were studied. All 6-minute walks took place in an enclosed, level, measured corridor and were supervised by the same nurse. Heart rate variability was measured by using (1) a standard-deviation method and (2) Poincaré plots. Data on RR intervals obtained by using 24-hour Holter monitoring were analyzed. Survival was determined at 1 year after the Holter recording. The results showed no significant associations between the results of the 6-minute walk and the two measures of heart rate variability. The results of the walk were related to 1-year mortality but not to the risk of sudden death. Both measures of heart rate variability had significant associations with 1-year mortality and with sudden death. However, only heart rate variability measured by using Poincaré plots was a predictor of total mortality and risk of sudden death, independent of left ventricular ejection fraction, serum levels of sodium, results of the 6-minute walk test, and the standard-deviation measure of heart rate variability. Results of the 6-minute walk have poor association with mortality and the two measures of heart rate variability in patients with advanced-stage heart failure and a low ejection fraction. Further studies are needed to determine the optimal clinical usefulness of the 6-minute walk and heart rate variability in patients with advanced-stage heart failure.

  2. Idiosyncratic heart rate response in men during sexual arousal.

    PubMed

    Rowland, David L; Crawford, Sara B

    2011-05-01

    Heart rate, sensitive to sympathetic activation, is known to change during sexual arousal and therefore may be a useful tool for investigating psychosomatic differences between sexually functional and dysfunctional men. However, heart rate during arousal also tends to be highly variable across individual men, making its predictability based on group patterns relatively poor. We wanted to determine whether individual men show idiosyncratic heart rate patterns during sexual arousal, that is, whether they exhibit consistent patterns across similar (though not identical) stimulus situations. Agreement between heart rates under the two conditions, visual sexual stimulation (VSS) and VSS + vibrotactile (VIB), was assessed using the concordance correlation coefficient (CCC).   Thirty-eight men, 25 of whom were diagnosed with premature ejaculation (PE), were monitored for penile response and heart rate under two similar (though not identical) conditions: a 9-minute erotic video (VSS), then a 9-minute erotic video combined with vibrotactile penile stimulation (VSS + VIB). CCC for men with PE was 0.65; for the sexually functional comparison group, CCC was 0.82. For both groups combined, CCC was 0.71. For all groupings, the CCC was relatively high, indicating agreement in heart rate from one session to the next within individual men. Despite high intersubject variation in heart rate patterns, individual men show signature heart rates across similar sexual stimulus sessions. Such stereotypy helps explain previous inconsistent findings and may also serve as a marker for the effectiveness of treatments designed to improve ejaculatory control in men with PE. © 2011 International Society for Sexual Medicine.

  3. Heart-rate pulse-shift detector

    NASA Technical Reports Server (NTRS)

    Anderson, M.

    1974-01-01

    Detector circuit accurately separates and counts phase-shift pulses over wide range of basic pulse-rate frequency, and also provides reasonable representation of full repetitive EKG waveform. Single telemeter implanted in small animal monitors not only body temperature but also animal movement and heart rate.

  4. The heart field effect: Synchronization of healer-subject heart rates in energy therapy.

    PubMed

    Bair, Christine Caldwell

    2008-01-01

    Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.

  5. Postural hypocapnic hyperventilation is associated with enhanced peripheral vasoconstriction in postural tachycardia syndrome with normal supine blood flow

    PubMed Central

    Stewart, Julian M.; Medow, Marvin S.; Cherniack, Neil S.; Natelson, Benjamin H.

    2015-01-01

    Previous investigations have demonstrated a subset of postural tachycardia syndrome (POTS) patients characterized by normal peripheral resistance and blood volume while supine but thoracic hypovolemia and splanchnic blood pooling while upright secondary to splanchnic hyperemia. Such “normal-flow” POTS patients often demonstrate hypocapnia during orthostatic stress. We studied 20 POTS patients (14–23 yr of age) and compared them with 10 comparably aged healthy volunteers. We measured changes in heart rate, blood pressure, heart rate and blood pressure variability, arm and leg strain-gauge occlusion plethysmography, respiratory impedance plethysmography calibrated against pneumotachography, end-tidal partial pressure of carbon dioxide (PetCO2), and impedance plethysmographic indexes of blood volume and blood flow within the thoracic, splanchnic, pelvic (upper leg), and lower leg regional circulations while supine and during upright tilt to 70°. Ten POTS patients demonstrated significant hyperventilation and hypocapnia (POTSHC) while 10 were normocapnic with minimal increase in postural ventilation, comparable to control. While relative splanchnic hypervolemia and hyperemia occurred in both POTS groups compared with controls, marked enhancement in peripheral vasoconstriction occurred only in POTSHC and was related to thoracic blood flow. Variability indexes suggested enhanced sympathetic activation in POTSHC compared with other subjects. The data suggest enhanced cardiac and peripheral sympathetic excitation in POTSHC. PMID:16565300

  6. Rate of change of heart size before congestive heart failure in dogs with mitral regurgitation.

    PubMed

    Lord, P; Hansson, K; Kvart, C; Häggström, J

    2010-04-01

    The objective of the study was to examine the changes in vertebral heart scale, and left atrial and ventricular dimensions before and at onset of congestive heart failure in cavalier King Charles spaniels with mitral regurgitation. Records and radiographs from 24 cavalier King Charles spaniels with mitral regurgitation were used. Vertebral heart scale (24 dogs), and left atrial dimension and left ventricular end diastolic and end systolic diameters (18 dogs) and their rate of increase were measured at intervals over years to the onset of congestive heart failure. They were plotted against time to onset of congestive heart failure. Dimensions and rates of change of all parameters were highest at onset of congestive heart failure, the difference between observed and chance outcome being highly significant using a two-tailed chi-square test (P<0.001). The left heart chambers increase in size rapidly only in the last year before the onset of congestive heart failure. Increasing left ventricular end systolic dimension is suggestive of myocardial failure before the onset of congestive heart failure. Rate of increase of heart dimensions may be a useful indicator of impending congestive heart failure.

  7. Reentry Tachycardia in Children: Adenosine Can Make It Worse.

    PubMed

    Hien, Maximilian D; Benito Castro, Fernando; Fournier, Philippe; Filleron, Anne; Tran, Tu-Anh

    2016-10-08

    We report on a rare but severe complication of adenosine use in a child with reentry tachycardia. Treatment with adenosine, which is the standard medical therapy of atrioventricular reentry tachycardia, led to the development of an irregular wide complex tachycardia, caused by rapid ventricular response to atrial fibrillation. The girl was finally stabilized with electrical cardioversion. We analyze the pathomechanism and discuss possible treatment options. Atrial fibrillation, as well as its conduction to the ventricles, can be caused by adenosine. Rapid ventricular response in children with Wolff-Parkinson-White syndrome is more frequent than previously believed. A patient history of atrial fibrillation is a contraindication for cardioversion with adenosine and needs to be assessed in children with reentry tachycardia. High-risk patients may potentially profit from prophylactic comedication with antiarrhythmic agents, such as flecainide, ibutilide, or vernakalant, before adenosine administration.

  8. Efficacy of Therapies for Postural Tachycardia Syndrome: A Systematic Review and Meta-analysis.

    PubMed

    Wells, Rachel; Elliott, Adrian D; Mahajan, Rajiv; Page, Amanda; Iodice, Valeria; Sanders, Prashanthan; Lau, Dennis H

    2018-06-21

    To identify the evidence base and evaluate the efficacy of each treatment for postural tachycardia syndrome (POTS) in light of a recent consensus statement highlighting the lack of treatment options with clear benefit to risk ratios for this debilitating condition. The CENTRAL (Cochrane Central Register of Controlled Trials), PubMed, and Embase databases from inception to May 2017 were searched using the terms postural AND tachycardia AND syndrome. A total of 135 full-text publications were screened after excluding duplicates (n=681), conference abstracts (n=467), and records that did not relate to POTS therapy (n=876). We included 28 studies with at least 4 patients with POTS in which symptomatic response was reported after more than 4 weeks of therapy. This review was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. Two investigators independently performed the data extraction and evaluated the quality of evidence. This study comprised 25 case series and 3 small randomized controlled trials that evaluated 755 and 103 patients with POTS, respectively. Interventions directed at increasing intravascular volume, increasing peripheral or splanchnic vascular tone, controlling heart rate, and increasing exercise tolerance demonstrate moderate efficacy (range, 51%-72%). Few data exist on their comparative effectiveness. Significant heterogeneities were seen in terms of patient age, symptom severity, and the measures used to evaluate treatment efficacy. The current evidence base to guide optimal management of patients with POTS is extremely limited. More high-quality collaborative research with standardized reporting of symptom response and treatment tolerability is urgently needed. Copyright © 2018 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  9. Assessing Heart Rate in Physical Education. Assessment Series: K-12 Physical Education.

    ERIC Educational Resources Information Center

    Buck, Marilyn M.

    This guide discusses the assessment of heart rate and, in particular, the assessment of heart rate using a heart monitor. Part 1, "Foundation for the Use of Heart Rate," reviews literature about heart rate assessment and heart rate monitors, offering an overview of national guidelines for physical activity. It focuses on the importance…

  10. Accuracy of Heart Rate Watches: Implications for Weight Management.

    PubMed

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  11. G protein-coupled estrogen receptor regulates embryonic heart rate in zebrafish

    PubMed Central

    Romano, Shannon N.; Edwards, Hailey E.; Ryan, Kevin J.

    2017-01-01

    Estrogens act by binding to estrogen receptors alpha and beta (ERα, ERβ), ligand-dependent transcription factors that play crucial roles in sex differentiation, tumor growth and cardiovascular physiology. Estrogens also activate the G protein-coupled estrogen receptor (GPER), however the function of GPER in vivo is less well understood. Here we find that GPER is required for normal heart rate in zebrafish embryos. Acute exposure to estrogens increased heart rate in wildtype and in ERα and ERβ mutant embryos but not in GPER mutants. GPER mutant embryos exhibited reduced basal heart rate, while heart rate was normal in ERα and ERβ mutants. We detected gper transcript in discrete regions of the brain and pituitary but not in the heart, suggesting that GPER acts centrally to regulate heart rate. In the pituitary, we observed gper expression in cells that regulate levels of thyroid hormone triiodothyronine (T3), a hormone known to increase heart rate. Compared to wild type, GPER mutants had reduced levels of T3 and estrogens, suggesting pituitary abnormalities. Exposure to exogenous T3, but not estradiol, rescued the reduced heart rate phenotype in gper mutant embryos, demonstrating that T3 acts downstream of GPER to regulate heart rate. Using genetic and mass spectrometry approaches, we find that GPER regulates maternal estrogen levels, which are required for normal embryonic heart rate. Our results demonstrate that estradiol plays a previously unappreciated role in the acute modulation of heart rate during zebrafish embryonic development and suggest that GPER regulates embryonic heart rate by altering maternal estrogen levels and embryonic T3 levels. PMID:29065151

  12. G protein-coupled estrogen receptor regulates embryonic heart rate in zebrafish.

    PubMed

    Romano, Shannon N; Edwards, Hailey E; Souder, Jaclyn Paige; Ryan, Kevin J; Cui, Xiangqin; Gorelick, Daniel A

    2017-10-01

    Estrogens act by binding to estrogen receptors alpha and beta (ERα, ERβ), ligand-dependent transcription factors that play crucial roles in sex differentiation, tumor growth and cardiovascular physiology. Estrogens also activate the G protein-coupled estrogen receptor (GPER), however the function of GPER in vivo is less well understood. Here we find that GPER is required for normal heart rate in zebrafish embryos. Acute exposure to estrogens increased heart rate in wildtype and in ERα and ERβ mutant embryos but not in GPER mutants. GPER mutant embryos exhibited reduced basal heart rate, while heart rate was normal in ERα and ERβ mutants. We detected gper transcript in discrete regions of the brain and pituitary but not in the heart, suggesting that GPER acts centrally to regulate heart rate. In the pituitary, we observed gper expression in cells that regulate levels of thyroid hormone triiodothyronine (T3), a hormone known to increase heart rate. Compared to wild type, GPER mutants had reduced levels of T3 and estrogens, suggesting pituitary abnormalities. Exposure to exogenous T3, but not estradiol, rescued the reduced heart rate phenotype in gper mutant embryos, demonstrating that T3 acts downstream of GPER to regulate heart rate. Using genetic and mass spectrometry approaches, we find that GPER regulates maternal estrogen levels, which are required for normal embryonic heart rate. Our results demonstrate that estradiol plays a previously unappreciated role in the acute modulation of heart rate during zebrafish embryonic development and suggest that GPER regulates embryonic heart rate by altering maternal estrogen levels and embryonic T3 levels.

  13. Procedural Pain Heart Rate Responses in Massaged Preterm Infants

    PubMed Central

    Diego, Miguel A.; Field, Tiffany; Hernandez-Reif, Maria

    2009-01-01

    Heart rate (HR) responses to the removal of a monitoring lead were assessed in 56 preterm infants who received moderate pressure, light pressure or no massage therapy. The infants who received moderate pressure massage therapy exhibited lower increases in HR suggesting an attenuated pain response. The heart rate of infants who received moderate pressure massage also returned to baseline faster than the heart rate of the other two groups, suggesting a faster recovery rate. PMID:19185352

  14. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    PubMed

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  15. Estimating 'lost heart beats' rather than reductions in heart rate during the intubation of critically-ill children.

    PubMed

    Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J

    2014-01-01

    Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.

  16. [Population characteristics and impact on heart rate variability, heart rate and blood pressure of passive smoking].

    PubMed

    Zhao, Jing; He, Fei; Hu, Da-yi; Ding, Rong-jing; Yu, Xiao-jun; Wang, Long; Zhang, Ping; Li, Xue-bin; Guo, Ji-hong; Liu, Wen-ling; Li, Cui-lan; Li, Lei; Gao, Chuan-yu; Zhao, Luo-sha; Chu, Ying-jie; Huang, Zhen-wen; Wei, Jing-han; Hua, Shao-hua; Liu, Rui-yun; Zhuang, Xiao-feng

    2013-05-01

    To investigate the basic characteristics of passive smoking population, and the impact of passive smoking on heart rate variability, heart rate and blood pressure. Eighty-six passive smokers [mean age: (52.4 ± 7.6) years] were recruited from patients and their relatives who visited cardiovascular outpatient department and excluded structural heart disease between June 2010 and June 2012, 80 normal subjects who were not exposed to smoking served as controls. Questionnaire survey, 24 hours ambulatory electrocardiogram examination and blood pressure measurement were performed in all recruited subjects. (1) Non-marriage rate [18.60% (16/86) vs. 3.75% (3/80), P < 0.01] was significantly higher while education level were significantly lower in passive smoking group than in control group. Passive smokers were more likely service industry workers [29.07% (25/86) vs. 15.00% (12/80), P < 0.05] and had longer daily working time [(7.56 ± 1.24) h vs. (6.02 ± 0.96) h, P < 0.01], and were less likely to be professional technology industry employers [20.93% (18/86) vs. 36.25% (29/80), P < 0.05] and managers [13.95% (12/86) vs. 38.75% (31/80), P < 0.01] compared to controls. The main place of passive smoking was workplace (67.44%, 58/86), entertainment venues (63.95%,55/86), restaurants (48.84%, 42/86). (2) Standard of the normal sinus RR intervals (SDNN), the normal consecutive sinus RR interval difference between the root-mean-square (rMSSD) and adjacent the difference between the RR interval>50 ms the number of share the percentage (PNN50) were significantly lower in passive smoking group than in the control group (all P < 0.05). Every 5 min average of the standard deviation of sinus RR cycle (SDNN index) and 24 h every 5 min sinus RR interval mean standard deviation (SDANN) were similar between the 2 groups (all P > 0.05). Ultra-low-frequency power (VLF), low frequency power (LF), high frequency power (HF) and LF/HF were significantly lower in passive smoking group than in

  17. Amiodarone prophylaxis for tachycardias after coronary artery surgery: a randomised, double blind, placebo controlled trial.

    PubMed Central

    Butler, J; Harriss, D R; Sinclair, M; Westaby, S

    1993-01-01

    BACKGROUND--Arrhythmias are a common cause of morbidity after cardiac surgery. This study assessed the efficacy of prophylactic amiodarone in reducing the incidence of atrial fibrillation or flutter and ventricular arrhythmias after coronary artery surgery. METHODS--A double blind, randomised, placebo controlled trial. 60 patients received a 24 hour intravenous infusion of amiodarone (15 mg/kg started after removal of the aortic cross clamp) followed by 200 mg orally three times daily for 5 days, and 60 patients received placebo. RESULTS--6 patients (10%) in the amiodarone group and 14 (23%) in the placebo group needed treatment for arrhythmias (95% confidence interval (95% CI) for the difference between groups was 0 to 26%, p = 0.05). The incidence of supraventricular tachycardia detected clinically and requiring treatment was lower in the amiodarone group (8% amiodarone v 20% placebo, 95% CI 0 to 24%, p = 0.07). The incidence detected by 24 hour Holter monitoring was similar (17% amiodarone v 20% placebo). Untreated arrhythmias in the amiodarone group were either clinically benign and undetected (n = 3) or the ventricular response rate was slow (n = 2). Age > 60 years was a positive risk factor for the development of supraventricular tachycardia in the amiodarone group but not in the placebo group. Fewer patients had episodes of ventricular tachycardia or fibrillation recorded on Holter monitoring in the amiodarone group (15% amiodarone v 33% placebo, 95% CI 3 to 33%, p = 0.02). Bradycardia (78% amiodarone v 48% placebo, 95% CI 14% to 46%, p < 0.005) and pauses (7% amiodarone v 0% placebo) occurred in more amiodarone treated patients. Bradycardia warranted discontinuation of treatment in one patient treated with amiodarone. CONCLUSIONS--The incidence of clinically significant tachycardia was reduced by amiodarone. The ventricular response rate was slowed in supraventricular tachycardia, but the induction of bradycardia may preclude the routine use of amiodarone

  18. Heart Rate and Outcomes in Hospitalized Patients With Heart Failure With Preserved Ejection Fraction.

    PubMed

    Lam, Phillip H; Dooley, Daniel J; Deedwania, Prakash; Singh, Steven N; Bhatt, Deepak L; Morgan, Charity J; Butler, Javed; Mohammed, Selma F; Wu, Wen-Chih; Panjrath, Gurusher; Zile, Michael R; White, Michel; Arundel, Cherinne; Love, Thomas E; Blackman, Marc R; Allman, Richard M; Aronow, Wilbert S; Anker, Stefan D; Fonarow, Gregg C; Ahmed, Ali

    2017-10-10

    A lower heart rate is associated with better outcomes in patients with heart failure (HF) with reduced ejection fraction (EF). Less is known about this association in patients with HF with preserved ejection fraction (HFpEF). The aims of this study were to examine associations of discharge heart rate with outcomes in hospitalized patients with HFpEF. Of the 8,873 hospitalized patients with HFpEF (EF ≥50%) in the Medicare-linked OPTIMIZE-HF (Organized Program to Initiate Lifesaving Treatment in Hospitalized Patients with Heart Failure) registry, 6,286 had a stable heart rate, defined as ≤20 beats/min variation between admission and discharge. Of these, 2,369 (38%) had a discharge heart rate of <70 beats/min. Propensity scores for discharge heart rate <70 beats/min, estimated for each of the 6,286 patients, were used to assemble a cohort of 2,031 pairs of patients with heart rate <70 versus ≥70 beats/min, balanced on 58 baseline characteristics. The 4,062 matched patients had a mean age of 79 ± 10 years, 66% were women, and 10% were African American. During 6 years (median 2.8 years) of follow-up, all-cause mortality was 65% versus 70% for matched patients with a discharge heart rate <70 versus ≥70 beats/min, respectively (hazard ratio [HR]: 0.86; 95% confidence interval [CI]: 0.80 to 0.93; p < 0.001). A heart rate <70 beats/min was also associated with a lower risk for the combined endpoint of HF readmission or all-cause mortality (HR: 0.90; 95% CI: 0.84 to 0.96; p = 0.002), but not with HF readmission (HR: 0.93; 95% CI: 0.85 to 1.01) or all-cause readmission (HR: 1.01; 95% CI: 0.95 to 1.08). Similar associations were observed regardless of heart rhythm or receipt of beta-blockers. Among hospitalized patients with HFpEF, a lower discharge heart rate was independently associated with a lower risk of all-cause mortality, but not readmission. Published by Elsevier Inc.

  19. Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity.

    PubMed

    Jarchi, Delaram; Casson, Alexander J

    2017-09-01

    Recently numerous methods have been proposed for estimating average heart rate using photoplethysmography (PPG) during physical activity, overcoming the significant interference that motion causes in PPG traces. We propose a new algorithm framework for extracting instantaneous heart rate from wearable PPG and Electrocardiogram (ECG) signals to provide an estimate of heart rate variability during exercise. For ECG signals, we propose a new spectral masking approach which modifies a particle filter tracking algorithm, and for PPG signals constrains the instantaneous frequency obtained from the Hilbert transform to a region of interest around a candidate heart rate measure. Performance is verified using accelerometry and wearable ECG and PPG data from subjects while biking and running on a treadmill. Instantaneous heart rate provides more information than average heart rate alone. The instantaneous heart rate can be extracted during motion to an accuracy of 1.75 beats per min (bpm) from PPG signals and 0.27 bpm from ECG signals. Estimates of instantaneous heart rate can now be generated from PPG signals during motion. These estimates can provide more information on the human body during exercise. Instantaneous heart rate provides a direct measure of vagal nerve and sympathetic nervous system activity and is of substantial use in a number of analyzes and applications. Previously it has not been possible to estimate instantaneous heart rate from wrist wearable PPG signals.

  20. Accuracy of Heart Rate Watches: Implications for Weight Management

    PubMed Central

    2016-01-01

    Background Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. Aim To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Methods Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). Results None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67–0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16–0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1–9%) but greater for energy expenditure (9–43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. Conclusion These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss. PMID:27232714

  1. Children's Heart Rate Reactivity Responses to Three School Tasks.

    ERIC Educational Resources Information Center

    Sharpley, Christopher F.; And Others

    1989-01-01

    Investigated effects of 3 routine classroom arithmetic and reading tasks upon the heart rate reactivity of 30 fifth grade children. Results indicated that some children showed large increases in heart rates during the three tasks, and that these children should be considered at risk for coronary heart disease. (Author/TE)

  2. Fighter pilots' heart rate, heart rate variation and performance during instrument approaches.

    PubMed

    Mansikka, Heikki; Simola, Petteri; Virtanen, Kai; Harris, Don; Oksama, Lauri

    2016-10-01

    Fighter pilots' heart rate (HR), heart rate variation (HRV) and performance during instrument approaches were examined. The subjects were required to fly instrument approaches in a high-fidelity simulator under various levels of task demand. The task demand was manipulated by increasing the load on the subjects by reducing the range at which they commenced the approach. HR and the time domain components of HRV were used as measures of pilot mental workload (PMWL). The findings of this study indicate that HR and HRV are sensitive to varying task demands. HR and HRV were able to distinguish the level of PMWL after which the subjects were no longer able to cope with the increasing task demands and their instrument landing system performance fell to a sub-standard level. The major finding was the HR/HRV's ability to differentiate the sub-standard performance approaches from the high-performance approaches. Practitioner Summary: This paper examined if HR and HRV were sensitive to varying task demands in a fighter aviation environment and if these measures were related to variations in pilot's performance.

  3. Heart Rate Fragmentation: A Symbolic Dynamical Approach.

    PubMed

    Costa, Madalena D; Davis, Roger B; Goldberger, Ary L

    2017-01-01

    Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability. Objective: The objectives of this study were to: (1) introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2) evaluate how the distribution of the different dynamical patterns ("words") varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD); and (3) quantify the differences in the fragmentation patterns between the two sample populations. Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words) with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW). Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed "soft" inflection points). In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to deceleration and vice

  4. Heart rate detection from an electronic weighing scale.

    PubMed

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2007-01-01

    We propose a novel technique for heart rate detection on a subject that stands on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear, and does not require any sensors attached to the body. We have applied our method to three different weighing scales, and estimated whether their sensitivity and frequency response suited heart rate detection. Scale sensitivities were from 490 nV/V/N to 1670 nV/V/N, all had an underdamped transient response and their dynamic gain error was below 19% at 10 Hz, which are acceptable values for heart rate estimation. We also designed a pulse detection system based on off-the-shelf integrated circuits, whose gain was about 70x10(3) and able to sense force variations about 240 mN. The signal-to-noise ratio (SNR) of the main peaks of the pulse signal detected was higher than 48 dB, which is large enough to estimate the heart rate by simple signal processing methods. To validate the method, the ECG and the force signal were simultaneously recorded on 12 volunteers. The maximal error obtained from heart rates determined from these two signals was +/-0.6 beats/minute.

  5. Heart Rate and Electrocardiography Monitoring in Mice

    PubMed Central

    Ho, David; Zhao, Xin; Gao, Shumin; Hong, Chull; Vatner, Dorothy E.; Vatner, Stephen F.

    2011-01-01

    The majority of current cardiovascular research involves studies in genetically engineered mouse models. The measurement of heart rate is central to understanding cardiovascular control under normal conditions, with altered autonomic tone, superimposed stress or disease states, both in wild type mice as well as those with altered genes. Electrocardiography (ECG) is the “gold standard” using either hard wire or telemetry transmission. In addition, heart rate is measured or monitored from the frequency of the arterial pressure pulse or cardiac contraction, or by pulse oximetry. For each of these techniques, discussions of materials and methods, as well as advantages and limitations are covered. However, only the direct ECG monitoring will determine not only the precise heart rates but also whether the cardiac rhythm is normal or not. PMID:21743842

  6. A randomised, simulated study assessing auscultation of heart rate at birth.

    PubMed

    Voogdt, Kevin G J A; Morrison, Allison C; Wood, Fiona E; van Elburg, Ruurd M; Wyllie, Jonathan P

    2010-08-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated resuscitation scenarios. The VitalSim((c)) manikin (Laerdal Medical, Stavanger, Norway) was used in this randomised, single blind study. Four heart rate settings (0, 40, 80, 120 beats per minute (bpm)) were randomly assigned. Participants assessed them by auscultation in three different scenarios. The first scenario was to assess the actual heart rate at birth. In the second scenario, heart rate was assessed during ventilation and assigned to standard ranges (<60, 60-100, >100bpm). In the third scenario, heart rate was assessed after three cycles of compressions and ventilation and assigned to standard ranges. In total 61 midwives, nurses and doctors performed 183 assessments. Mean time to estimate heart rate for scenarios 1, 2 and 3 was: 17.0, 9.8 and 7.8s respectively. Heart rate assessments were inaccurate in 31% (scenario 1), 28% (scenarios 2) and 26% (scenario 3). There was a trend for assessors who were accurate to be quicker and this achieved significance in scenario 2 (p<0.02). Inaccurate assessment would have made a difference to management in 28% of all cases. Mean time to estimate heart rate for the scenarios varied between 7.8 and 17.0s. Twenty-eight percent of all heart rate assessments would have prompted incorrect management during resuscitation or stabilization. Of incorrect assessments, 73% were overestimations. Further research is required to develop a rapid and accurate method for determining heart rate during newborn resuscitation. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for

  8. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for

  9. Heart Rate at Hospital Discharge in Patients With Heart Failure Is Associated With Mortality and Rehospitalization

    PubMed Central

    Laskey, Warren K.; Alomari, Ihab; Cox, Margueritte; Schulte, Phillip J.; Zhao, Xin; Hernandez, Adrian F.; Heidenreich, Paul A.; Eapen, Zubin J.; Yancy, Clyde; Bhatt, Deepak L.; Fonarow, Gregg C.

    2015-01-01

    Background Whether heart rate upon discharge following hospitalization for heart failure is associated with long‐term adverse outcomes and whether this association differs between patients with sinus rhythm (SR) and atrial fibrillation (AF) have not been well studied. Methods and Results We conducted a retrospective cohort study from clinical registry data linked to Medicare claims for 46 217 patients participating in Get With The Guidelines®–Heart Failure. Cox proportional‐hazards models were used to estimate the association between discharge heart rate and all‐cause mortality, all‐cause readmission, and the composite outcome of mortality/readmission through 1 year. For SR and AF patients with heart rate ≥75, the association between heart rate and mortality (expressed as hazard ratio [HR] per 10 beats‐per‐minute increment) was significant at 0 to 30 days (SR: HR 1.30, 95% CI 1.22 to 1.39; AF: HR 1.23, 95% CI 1.16 to 1.29) and 31 to 365 days (SR: HR 1.15, 95% CI 1.12 to 1.20; AF: HR 1.05, 95% CI 1.01 to 1.08). Similar associations between heart rate and all‐cause readmission and the composite outcome were obtained for SR and AF patients from 0 to 30 days but only in the composite outcome for SR patients over the longer term. The HR from 0 to 30 days exceeded that from 31 to 365 days for both SR and AF patients. At heart rates <75, an association was significant for mortality only for both SR and AF patients. Conclusions Among older patients hospitalized with heart failure, higher discharge heart rate was associated with increased risks of death and rehospitalization, with higher risk in the first 30 days and for SR compared with AF. PMID:25904590

  10. Monitoring nocturnal heart rate with bed sensor.

    PubMed

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  11. Asymmetric acceleration/deceleration dynamics in heart rate variability

    NASA Astrophysics Data System (ADS)

    Alvarez-Ramirez, J.; Echeverria, J. C.; Meraz, M.; Rodriguez, E.

    2017-08-01

    The heart rate variability (HRV) is an important physiological signal used either to assess the risk of cardiac death or to model the cardiovascular regulatory dynamics. Asymmetries in HRV data have been observed using 2D Poincare plots, which have been linked to a non-equilibrium operation of the cardiac autonomic system. This work further explores the presence of asymmetries but in the serial correlations of the dynamics of HRV data. To this end, detrended fluctuation analysis (DFA) was used to estimate the Hurst exponent both when the heart rate is accelerating and when it is decelerating. The analysis is conducted using data collected from subjects under normal sinus rhythm (NSR), congestive heart failure (CHF) and atrial fibrillation (AF) . For the NSR cases, it was found that correlations are stronger (p < 0 . 05) when the heart rate is accelerating than when it is decelerating over different scales in the range 20-40 beats. In contrast, the opposite behavior was detected for the CHF and AF patients. Possible links between asymmetric correlations in the dynamics and the mechanisms controlling the operation of the heart rate are discussed, as well as their implications for modeling the cardiovascular regulatory dynamics.

  12. Long-term effectiveness of surgical treatment of ectopic atrial tachycardia.

    PubMed

    Prager, N A; Cox, J L; Lindsay, B D; Ferguson, T B; Osborn, J L; Cain, M E

    1993-07-01

    The purpose of this study was to determine the long-term clinical outcome of patients with ectopic atrial tachycardias treated surgically. Ectopic atrial tachycardia is an uncommon arrhythmia that can be symptomatic and is associated with the development of a cardiomyopathy. Management strategies are not well defined because of the paucity of data on the long-term effectiveness of pharmacologic and nonpharmacologic therapies. The long-term clinical impact of medical and surgical therapy was determined in 15 consecutive patients with ectopic atrial tachycardia. All 15 patients were initially treated with antiarrhythmic drugs (mean 5.7 +/- 2.2 drugs/patient). An effective drug regimen was identified in only 5 (33%) of the 15 patients; the remaining 10 patients were treated surgically. In each, individualized surgical procedures were guided by computer-assisted intraoperative mapping, with atrial plaques comprising up to 156 electrodes. Focal ablation was performed in four patients and atrial isolation procedures in six. The 10 patients treated surgically were followed up a mean of 4 +/- 3.2 years. Ectopic atrial tachycardia recurred in one patient. A permanent pacemaker was implanted in two patients, one of whom also required reoperation for constrictive pericarditis. There were no operative deaths. Ectopic atrial tachycardia recurred in three (60%) of the five patients discharged on antiarrhythmic drug therapy during a mean follow-up interval of 6.4 +/- 4.3 years. There was one nonarrhythmic death. Map-guided surgery demonstrated long-term efficacy in abolishing symptoms in 9 of the 10 patients with ectopic atrial tachycardia. Results demonstrate that surgery is effective for patients with ectopic atrial tachycardias who are not easily treated with antiarrhythmic drugs.

  13. Heart Rate and Heart Rate Variability in Dairy Cows with Different Temperament and Behavioural Reactivity to Humans

    PubMed Central

    Tőzsér, János; Szenci, Ottó; Póti, Péter; Pajor, Ferenc

    2015-01-01

    From the 1990s, extensive research was started on the physiological aspects of individual traits in animals. Previous research has established two extreme (proactive and reactive) coping styles in several animal species, but the means of reactivity with the autonomic nervous system (ANS) activity has not yet been investigated in cattle. The aim of this study was the characterization of cardiac autonomic activity under different conditions in cows with different individual characteristics. For this purpose, we investigated heart rate and ANS-related heart rate variability (HRV) parameters of dairy cows (N = 282) on smaller- and larger-scale farms grouped by (1) temperament and (2) behavioural reactivity to humans (BRH). Animals with high BRH scores were defined as impulsive, while animals with low BRH scores were defined as reserved. Cardiac parameters were calculated for undisturbed lying (baseline) and for milking bouts, the latter with the presence of an unfamiliar person (stressful situation). Sympathetic tone was higher, while vagal activity was lower in temperamental cows than in calm animals during rest both on smaller- and larger-scale farms. During milking, HRV parameters were indicative of a higher sympathetic and a lower vagal activity of temperamental cows as compared to calm ones in farms of both sizes. Basal heart rate did not differ between BRH groups either on smaller- or larger-scale farms. Differences between basal ANS activity of impulsive and reserved cows reflected a higher resting vagal and lower sympathetic activity of reserved animals compared to impulsive ones both on smaller- and larger-scale farms. There was no difference either in heart rate or in HRV parameters between groups during milking neither in smaller- nor in larger-scale farms. These two groupings allowed to draw possible parallels between personality and cardiac autonomic activity during both rest and milking in dairy cows. Heart rate and HRV seem to be useful for

  14. Fighter pilots' heart rate, heart rate variation and performance during an instrument flight rules proficiency test.

    PubMed

    Mansikka, Heikki; Virtanen, Kai; Harris, Don; Simola, Petteri

    2016-09-01

    Increased task demand will increase the pilot mental workload (PMWL). When PMWL is increased, mental overload may occur resulting in degraded performance. During pilots' instrument flight rules (IFR) proficiency test, PMWL is typically not measured. Therefore, little is known about workload during the proficiency test and pilots' potential to cope with higher task demands than those experienced during the test. In this study, fighter pilots' performance and PMWL was measured during a real IFR proficiency test in an F/A-18 simulator. PMWL was measured using heart rate (HR) and heart rate variation (HRV). Performance was rated using Finnish Air Force's official rating scales. Results indicated that HR and HRV differentiate varying task demands in situations where variations in performance are insignificant. It was concluded that during a proficiency test, PMWL should be measured together with the task performance measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia.

    PubMed

    Burkhardt, J David; Saliba, Walid I; Schweikert, Robert A; Cummings, Jennifer; Natale, Andrea

    2006-10-01

    Premature ventricular contractions (PVCs) and ventricular tachycardia may arise from the coronary cusps. Navigation, mapping, and ablation in the coronary cusps can be challenging. Remote magnetic navigation may offer an alternative to conventional manually operated catheters. We report a case of left coronary cusp ventricular tachycardia ablation using remote magnetic navigation. Right ventricular outflow tract and coronary cusp mapping, and ablation of the left coronary cusp using a remote magnetic navigation and three-dimensional (3-D) mapping system was performed in a 28-year-old male with frequent, symptomatic PVCs and ventricular tachycardia. Successful ablation of left coronary cusp ventricular tachycardia was performed using remote magnetic navigation. Remote magnetic navigation may be used to map and ablate PVCs and ventricular tachycardia originating from the coronary cusps.

  16. Validation of heart rate extraction through an iPhone accelerometer.

    PubMed

    Kwon, Sungjun; Lee, Jeongsu; Chung, Gih Sung; Park, Kwang Suk

    2011-01-01

    Ubiquitous medical technology may provide advanced utility for evaluating the status of the patient beyond the clinical environment. The iPhone provides the capacity to measure the heart rate, as the iPhone consists of a 3-axis accelerometer that is sufficiently sensitive to perceive tiny body movements caused by heart pumping. In this preliminary study, an iPhone was tested and evaluated as the reliable heart rate extractor to use for medical purpose by comparing with reference electrocardiogram. By comparing the extracted heart rate from acquired acceleration data with the extracted one from ECG reference signal, iPhone functioning as the reliable heart rate extractor has demonstrated sufficient accuracy and consistency.

  17. Heart rates increase after hatching in two species of natricine snakes

    PubMed Central

    Aubret, Fabien

    2013-01-01

    Experimental studies have shown heart rates to decrease from embryo to hatchling stage in turtles, remain steady in skinks, and increase in birds. However, no snake species has been studied in this regard. I recorded heart rate evolution trajectories from embryo to juvenile stage in 78 eggs from two species of European Natricine snakes. Unexpectedly, snakes behaved more like birds than turtles or lizards: heart rates increased after hatching in both N. maura and N. natrix, respectively by 43.92 ± 22.84% and 35.92 ± 24.52%. Heart rate shift was not related to an abrupt elevation of metabolism per se (snakes that increased their heart rates the most sharply grew the least after birth), but rather due to a number of smaller eggs that experienced lower than normal heart rates throughout the incubation and recovered a normal heart rate post-birth. This finding is discussed in the light of hatching synchrony benefits. PMID:24287712

  18. When heart goes “BOOM” to fast. Heart rate greater than 80 as mortality predictor in acute myocardial infarction

    PubMed Central

    Davidovic, Goran; Iric-Cupic, Violeta; Milanov, Srdjan; Dimitijevic, Aleksandra; Petrovic-Janicijevic, Mirjana

    2013-01-01

    Many prospective studies established association between high heart rate and increased cardiovascular morbidity and mortality, independently of other risk factors. Heart rate over 80 beats per minute more often leads to atherosclerotic plaque disruption, the main step in developing acute coronary syndrome. Purpose was to investigate the incidence of higher heart rate levels in patients with anterior wall acute myocardial infarction with ST-segment elevation and the influence of heart rate on mortality. Research included 140 patients with anterior wall acute myocardial infarction with ST-segment elevation treated in Coronary Unit, Clinical Center Kragujevac in the period from January 2001-June 2006. Heart rate was calculated as the mean value of baseline and heart rate in the first 30 minutes after admission. Other risk factors were also followed to determine their connection with elevated heart rate. Results showed that the majority of patients survived (over 70%). In a total number of patients, more than 75% had a heart rate levels greater than 80 beats per minute. There was a significant difference in heart rate on addmision between survivors and patients who died, with a greater levels in patients with fatal outcome. Both, univariate and multivariate regression analysis singled out heart rate greater than 80 beats per minute as independent mortality predictor in these patients. Heart rate greater than 80 beats per minute is a major, independent risk factor for morbidity and important predictor of mortality in patients with acute myocardial infarction. PMID:23991346

  19. Phase Transition in a Healthy Human Heart Rate

    NASA Astrophysics Data System (ADS)

    Kiyono, Ken; Struzik, Zbigniew R.; Aoyagi, Naoko; Togo, Fumiharu; Yamamoto, Yoshiharu

    2005-07-01

    A healthy human heart rate displays complex fluctuations which share characteristics of physical systems in a critical state. We demonstrate that the human heart rate in healthy individuals undergoes a dramatic breakdown of criticality characteristics, reminiscent of continuous second order phase transitions. By studying the germane determinants, we show that the hallmark of criticality—highly correlated fluctuations—is observed only during usual daily activity, and a breakdown of these characteristics occurs in prolonged, strenuous exercise and sleep. This finding is the first reported discovery of the dynamical phase transition phenomenon in a biological control system and will be a key to understanding the heart rate control system in health and disease.

  20. Elucidation of the Strongest Predictors of Cardiovascular Events in Patients with Heart Failure.

    PubMed

    Fukuda, Hiroki; Shindo, Kazuhiro; Sakamoto, Mari; Ide, Tomomi; Kinugawa, Shintaro; Fukushima, Arata; Tsutsui, Hiroyuki; Ito, Shin; Ishii, Akira; Washio, Takashi; Kitakaze, Masafumi

    2018-06-20

    In previous retrospective studies, we identified the 50 most influential clinical predictors of cardiovascular outcomes in patients with heart failure (HF). The present study aimed to use the novel limitless-arity multiple-testing procedure to filter these 50 clinical factors and thus yield combinations of no more than four factors that could potentially predict the onset of cardiovascular events. A Kaplan-Meier analysis was used to investigate the importance of the combinations. In a multi-centre observational trial, we prospectively enrolled 213 patients with HF who were hospitalized because of exacerbation, discharged according to HF treatment guidelines and observed to monitor cardiovascular events. After the observation period, we stratified patients according to whether they experienced cardiovascular events (rehospitalisation or cardiovascular death). Among 77,562 combinations of fewer than five clinical parameters, we identified 151 combinations that could potentially explain the occurrence of cardiovascular events. Of these, 145 combinations included the use of inotropic agents, whereas the remaining 6 included the use of diuretics without bradycardia or tachycardia, suggesting that the high probability of cardiovascular events is exclusively determined by these two clinical factors. Importantly, Kaplan-Meier curves demonstrated that the use of inotropes or of diuretics without bradycardia or tachycardia were independent predictors of a markedly worse cardiovascular prognosis. Patients treated with either inotropic agents or diuretics without bradycardia or tachycardia were at a higher risk of cardiovascular events. The uses of these drugs, regardless of heart rate, are the strongest clinical predictors of cardiovascular events in patients with HF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Heart Rates in Hospitalized Children by Age and Body Temperature

    PubMed Central

    Bonafide, Christopher P.; Brady, Patrick W.

    2015-01-01

    BACKGROUND AND OBJECTIVES: Heart rate (HR) is frequently used by clinicians in the hospital to assess a patient’s severity of illness and make treatment decisions. We sought to develop percentiles that characterize the relationship of expected HR by age and body temperature in hospitalized children and to compare these percentiles with published references in both primary care and emergency department (ED) settings. METHODS: Vital sign data were extracted from electronic health records of inpatients <18 years of age at 2 large freestanding children’s hospitals from July 2011 to June 2012. We selected up to 10 HR-temperature measurement pairs from each admission. Measurements from 60% of patients were used to derive the percentile curves, with the remainder used for validation. We compared our upper percentiles with published references in primary care and ED settings. RESULTS: We used 60 863 observations to derive the percentiles. Overall, an increase in body temperature of 1°C was associated with an increase of ∼10 beats per minute in HR, although there were variations across age and temperature ranges. For infants and young children, our upper percentiles were lower than in primary care and ED settings. For school-age children, our upper percentiles were higher. CONCLUSIONS: We characterized expected HR by age and body temperature in hospitalized children. These percentiles differed from references in primary care and ED settings. Additional research is needed to evaluate the performance of these percentiles for the identification of children who would benefit from further evaluation or intervention for tachycardia. PMID:25917984

  2. Heart rates in hospitalized children by age and body temperature.

    PubMed

    Daymont, Carrie; Bonafide, Christopher P; Brady, Patrick W

    2015-05-01

    Heart rate (HR) is frequently used by clinicians in the hospital to assess a patient's severity of illness and make treatment decisions. We sought to develop percentiles that characterize the relationship of expected HR by age and body temperature in hospitalized children and to compare these percentiles with published references in both primary care and emergency department (ED) settings. Vital sign data were extracted from electronic health records of inpatients <18 years of age at 2 large freestanding children's hospitals from July 2011 to June 2012. We selected up to 10 HR-temperature measurement pairs from each admission. Measurements from 60% of patients were used to derive the percentile curves, with the remainder used for validation. We compared our upper percentiles with published references in primary care and ED settings. We used 60,863 observations to derive the percentiles. Overall, an increase in body temperature of 1°C was associated with an increase of ∼ 10 beats per minute in HR, although there were variations across age and temperature ranges. For infants and young children, our upper percentiles were lower than in primary care and ED settings. For school-age children, our upper percentiles were higher. We characterized expected HR by age and body temperature in hospitalized children. These percentiles differed from references in primary care and ED settings. Additional research is needed to evaluate the performance of these percentiles for the identification of children who would benefit from further evaluation or intervention for tachycardia. Copyright © 2015 by the American Academy of Pediatrics.

  3. Heart Rate Response in Spectators of the Montreal Canadiens Hockey Team.

    PubMed

    Khairy, Leia T; Barin, Roxana; Demonière, Fabrice; Villemaire, Christine; Billo, Marie-Josée; Tardif, Jean-Claude; Macle, Laurent; Khairy, Paul

    2017-12-01

    To our knowledge, heart rate responses have not previously been assessed in hockey fans. We quantified heart rate increases in spectators of the Montreal Canadiens, compared televised with live games, explored features associated with peak heart rates, and assessed whether increases correlate with a fan passion score. Healthy adults were enrolled, with half attending live games and half viewing televised games. All subjects completed questionnaires and had continuous Holter monitoring. Intensity of the physical stress response was defined according to previously published heart rate index thresholds as mild (< 1.33), moderate (1.33-1.83), or vigorous (> 1.83). In 20 participants, 35% women, age 46 ± 10 years, the heart rate increased by a median of 92% during the hockey game, from 60 (interquartile range, 54-65) beats per minute at rest to 114 (interquartile range, 103-129) beats per minute (P < 0.001). The heart rate increased by 110% vs 75% during live vs televised games (P < 0.001). Heart rate index (2.16 ± 0.27 vs 1.73 ± 0.15; P < 0.001) and percent maximum predicted heart rate attained (75% ± 8% vs 58% ± 7%; P < 0.001) were significantly higher during live vs televised games. Number of premature beats was nonsignificantly higher during live games (5 vs 1; P = 0.181). The fan passion score was not predictive of the heart rate response (P = 0.753). Peak heart rates most commonly occurred during overtime (40%) and scoring opportunities for (25%) and against (15%). It is exciting to watch the Montreal Canadiens! Viewing a live hockey game is associated with a heart rate response equivalent to vigorous physical stress and a televised game to moderate physical stress. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  4. Interesting Electrophysiological Findings in a Patient With Coincidental Right Ventricular Outflow Tract and Atrioventricular Nodal Reentrant Tachycardia

    PubMed Central

    Ozin, Bulent; Pirat, Bahar; Muderrisoglu, Haldun

    2004-01-01

    Tachycardia induced tachycardias are not common in clinical practice, and it is believed that most cases of double tachycardia are coincidental. The existence of two different tachycardias in the same patient almost always poses problems in the electrophysiology laboratory. However, in rare instances, the emergence of a second tachycardia can actually provide invaluable information about the first one. In this report, we describe a 30-year-old woman who presented with palpitations. Electrophysiological study revealed that atrial programmed stimulation at baseline induced right ventricular outflow tract (RVOT) tachycardia and supraventricular tachycardia. The study also showed that each of the tachycardias was able to induce the other. A short run of RVOT tachycardia during supraventricular tachycardia was able to entrain the latter. This finding provided important information about the nature of the supraventricular tachycardia, which proved to be atrioventricular nodal reentrant tachycardia. Both of these tachycardias were successfully ablated, and the patient’s palpitations disappeared. PMID:16943976

  5. Resting Heart Rate as Predictor for Left Ventricular Dysfunction and Heart Failure: The Multi-Ethnic Study of Atherosclerosis

    PubMed Central

    Opdahl, Anders; Venkatesh, Bharath Ambale; Fernandes, Veronica R. S.; Wu, Colin O.; Nasir, Khurram; Choi, Eui-Young; Almeida, Andre L. C.; Rosen, Boaz; Carvalho, Benilton; Edvardsen, Thor; Bluemke, David A.; Lima, Joao A. C.

    2014-01-01

    OBJECTIVE To investigate the relationship between baseline resting heart rate and incidence of heart failure (HF) and global and regional left ventricular (LV) dysfunction. BACKGROUND The association of resting heart rate to HF and LV function is not well described in an asymptomatic multi-ethnic population. METHODS Participants in the Multi-Ethnic Study of Atherosclerosis had resting heart rate measured at inclusion. Incident HF was registered (n=176) during follow-up (median 7 years) in those who underwent cardiac MRI (n=5000). Changes in ejection fraction (ΔEF) and peak circumferential strain (Δεcc) were measured as markers of developing global and regional LV dysfunction in 1056 participants imaged at baseline and 5 years later. Time to HF (Cox model) and Δεcc and ΔEF (multiple linear regression models) were adjusted for demographics, traditional cardiovascular risk factors, calcium score, LV end-diastolic volume and mass in addition to resting heart rate. RESULTS Cox analysis demonstrated that for 1 bpm increase in resting heart rate there was a 4% greater adjusted relative risk for incident HF (Hazard Ratio: 1.04 (1.02, 1.06 (95% CI); P<0.001). Adjusted multiple regression models demonstrated that resting heart rate was positively associated with deteriorating εcc and decrease in EF, even in analyses when all coronary heart disease events were excluded from the model. CONCLUSION Elevated resting heart rate is associated with increased risk for incident HF in asymptomatic participants in MESA. Higher heart rate is related to development of regional and global LV dysfunction independent of subclinical atherosclerosis and coronary heart disease. PMID:24412444

  6. Evaluation of the metabolic rate based on the recording of the heart rate.

    PubMed

    Malchaire, Jacques; d'AMBROSIO Alfano, Francesca Romana; Palella, Boris Igor

    2017-06-08

    The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%.

  7. Evaluation of the metabolic rate based on the recording of the heart rate

    PubMed Central

    MALCHAIRE, Jacques; ALFANO, Francesca Romana d’AMBROSIO; PALELLA, Boris Igor

    2017-01-01

    The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%. PMID:28250334

  8. Effect of Selective Heart Rate Slowing in Heart Failure With Preserved Ejection Fraction.

    PubMed

    Pal, Nikhil; Sivaswamy, Nadiya; Mahmod, Masliza; Yavari, Arash; Rudd, Amelia; Singh, Satnam; Dawson, Dana K; Francis, Jane M; Dwight, Jeremy S; Watkins, Hugh; Neubauer, Stefan; Frenneaux, Michael; Ashrafian, Houman

    2015-11-03

    Heart failure with preserved ejection fraction (HFpEF) is associated with significant morbidity and mortality but is currently refractory to therapy. Despite limited evidence, heart rate reduction has been advocated, on the basis of physiological considerations, as a therapeutic strategy in HFpEF. We tested the hypothesis that heart rate reduction improves exercise capacity in HFpEF. We conducted a randomized, crossover study comparing selective heart rate reduction with the If blocker ivabradine at 7.5 mg twice daily versus placebo for 2 weeks each in 22 symptomatic patients with HFpEF who had objective evidence of exercise limitation (peak oxygen consumption at maximal exercise [o2 peak] <80% predicted for age and sex). The result was compared with 22 similarly treated matched asymptomatic hypertensive volunteers. The primary end point was the change in o2 peak. Secondary outcomes included tissue Doppler-derived E/e' at echocardiography, plasma brain natriuretic peptide, and quality-of-life scores. Ivabradine significantly reduced peak heart rate compared with placebo in the HFpEF (107 versus 129 bpm; P<0.0001) and hypertensive (127 versus 145 bpm; P=0.003) cohorts. Ivabradine compared with placebo significantly worsened the change in o2 peak in the HFpEF cohort (-2.1 versus 0.9 mL·kg(-1)·min(-1); P=0.003) and significantly reduced submaximal exercise capacity, as determined by the oxygen uptake efficiency slope. No significant effects on the secondary end points were discernable. Our observations bring into question the value of heart rate reduction with ivabradine for improving symptoms in a HFpEF population characterized by exercise limitation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02354573. © 2015 The Authors.

  9. Discovery of novel heart rate-associated loci using the Exome Chip

    PubMed Central

    van den Berg, Marten E.; Warren, Helen R.; Cabrera, Claudia P.; Verweij, Niek; Mifsud, Borbala; Haessler, Jeffrey; Bihlmeyer, Nathan A.; Fu, Yi-Ping; Weiss, Stefan; Lin, Henry J.; Grarup, Niels; Li-Gao, Ruifang; Pistis, Giorgio; Shah, Nabi; Brody, Jennifer A.; Müller-Nurasyid, Martina; Lin, Honghuang; Mei, Hao; Smith, Albert V.; Lyytikäinen, Leo-Pekka; Hall, Leanne M.; van Setten, Jessica; Trompet, Stella; Prins, Bram P.; Isaacs, Aaron; Radmanesh, Farid; Marten, Jonathan; Entwistle, Aiman; Kors, Jan A.; Silva, Claudia T.; Alonso, Alvaro; Bis, Joshua C.; de Boer, Rudolf; de Haan, Hugoline G.; de Mutsert, Renée; Dedoussis, George; Dominiczak, Anna F.; Doney, Alex S. F.; Ellinor, Patrick T.; Eppinga, Ruben N.; Felix, Stephan B.; Guo, Xiuqing; Hagemeijer, Yanick; Hansen, Torben; Harris, Tamara B.; Heckbert, Susan R.; Huang, Paul L.; Hwang, Shih-Jen; Kähönen, Mika; Kanters, Jørgen K.; Kolcic, Ivana; Launer, Lenore J.; Li, Man; Yao, Jie; Linneberg, Allan; Liu, Simin; Macfarlane, Peter W.; Mangino, Massimo; Morris, Andrew D.; Mulas, Antonella; Murray, Alison D.; Nelson, Christopher P.; Orrú, Marco; Padmanabhan, Sandosh; Peters, Annette; Porteous, David J.; Poulter, Neil; Psaty, Bruce M.; Qi, Lihong; Raitakari, Olli T.; Rivadeneira, Fernando; Roselli, Carolina; Rudan, Igor; Sattar, Naveed; Sever, Peter; Sinner, Moritz F.; Soliman, Elsayed Z.; Spector, Timothy D.; Stanton, Alice V.; Stirrups, Kathleen E.; Taylor, Kent D.; Tobin, Martin D.; Uitterlinden, André; Vaartjes, Ilonca; Hoes, Arno W.; van der Meer, Peter; Völker, Uwe; Waldenberger, Melanie; Xie, Zhijun; Zoledziewska, Magdalena; Tinker, Andrew; Polasek, Ozren; Rosand, Jonathan; Jamshidi, Yalda; van Duijn, Cornelia M.; Zeggini, Eleftheria; Jukema, J. Wouter; Asselbergs, Folkert W.; Samani, Nilesh J.; Lehtimäki, Terho; Gudnason, Vilmundur; Wilson, James; Lubitz, Steven A.; Kääb, Stefan; Sotoodehnia, Nona; Caulfield, Mark J.; Palmer, Colin N. A.; Sanna, Serena; Mook-Kanamori, Dennis O.; Deloukas, Panos; Pedersen, Oluf; Rotter, Jerome I.; Dörr, Marcus; O'Donnell, Chris J.; Hayward, Caroline; Arking, Dan E.; Kooperberg, Charles; van der Harst, Pim; Eijgelsheim, Mark; Stricker, Bruno H.; Munroe, Patricia B.

    2017-01-01

    Abstract Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to discover new genetic loci associated with heart rate from Exome Chip meta-analyses. Heart rate was measured from either elecrtrocardiograms or pulse recordings. We meta-analysed heart rate association results from 104 452 European-ancestry individuals from 30 cohorts, genotyped using the Exome Chip. Twenty-four variants were selected for follow-up in an independent dataset (UK Biobank, N = 134 251). Conditional and gene-based testing was undertaken, and variants were investigated with bioinformatics methods. We discovered five novel heart rate loci, and one new independent low-frequency non-synonymous variant in an established heart rate locus (KIAA1755). Lead variants in four of the novel loci are non-synonymous variants in the genes C10orf71, DALDR3, TESK2 and SEC31B. The variant at SEC31B is significantly associated with SEC31B expression in heart and tibial nerve tissue. Further candidate genes were detected from long-range regulatory chromatin interactions in heart tissue (SCD, SLF2 and MAPK8). We observed significant enrichment in DNase I hypersensitive sites in fetal heart and lung. Moreover, enrichment was seen for the first time in human neuronal progenitor cells (derived from embryonic stem cells) and fetal muscle samples by including our novel variants. Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies. PMID:28379579

  10. Discovery of novel heart rate-associated loci using the Exome Chip.

    PubMed

    van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P; Verweij, Niek; Mifsud, Borbala; Haessler, Jeffrey; Bihlmeyer, Nathan A; Fu, Yi-Ping; Weiss, Stefan; Lin, Henry J; Grarup, Niels; Li-Gao, Ruifang; Pistis, Giorgio; Shah, Nabi; Brody, Jennifer A; Müller-Nurasyid, Martina; Lin, Honghuang; Mei, Hao; Smith, Albert V; Lyytikäinen, Leo-Pekka; Hall, Leanne M; van Setten, Jessica; Trompet, Stella; Prins, Bram P; Isaacs, Aaron; Radmanesh, Farid; Marten, Jonathan; Entwistle, Aiman; Kors, Jan A; Silva, Claudia T; Alonso, Alvaro; Bis, Joshua C; de Boer, Rudolf; de Haan, Hugoline G; de Mutsert, Renée; Dedoussis, George; Dominiczak, Anna F; Doney, Alex S F; Ellinor, Patrick T; Eppinga, Ruben N; Felix, Stephan B; Guo, Xiuqing; Hagemeijer, Yanick; Hansen, Torben; Harris, Tamara B; Heckbert, Susan R; Huang, Paul L; Hwang, Shih-Jen; Kähönen, Mika; Kanters, Jørgen K; Kolcic, Ivana; Launer, Lenore J; Li, Man; Yao, Jie; Linneberg, Allan; Liu, Simin; Macfarlane, Peter W; Mangino, Massimo; Morris, Andrew D; Mulas, Antonella; Murray, Alison D; Nelson, Christopher P; Orrú, Marco; Padmanabhan, Sandosh; Peters, Annette; Porteous, David J; Poulter, Neil; Psaty, Bruce M; Qi, Lihong; Raitakari, Olli T; Rivadeneira, Fernando; Roselli, Carolina; Rudan, Igor; Sattar, Naveed; Sever, Peter; Sinner, Moritz F; Soliman, Elsayed Z; Spector, Timothy D; Stanton, Alice V; Stirrups, Kathleen E; Taylor, Kent D; Tobin, Martin D; Uitterlinden, André; Vaartjes, Ilonca; Hoes, Arno W; van der Meer, Peter; Völker, Uwe; Waldenberger, Melanie; Xie, Zhijun; Zoledziewska, Magdalena; Tinker, Andrew; Polasek, Ozren; Rosand, Jonathan; Jamshidi, Yalda; van Duijn, Cornelia M; Zeggini, Eleftheria; Jukema, J Wouter; Asselbergs, Folkert W; Samani, Nilesh J; Lehtimäki, Terho; Gudnason, Vilmundur; Wilson, James; Lubitz, Steven A; Kääb, Stefan; Sotoodehnia, Nona; Caulfield, Mark J; Palmer, Colin N A; Sanna, Serena; Mook-Kanamori, Dennis O; Deloukas, Panos; Pedersen, Oluf; Rotter, Jerome I; Dörr, Marcus; O'Donnell, Chris J; Hayward, Caroline; Arking, Dan E; Kooperberg, Charles; van der Harst, Pim; Eijgelsheim, Mark; Stricker, Bruno H; Munroe, Patricia B

    2017-06-15

    Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to discover new genetic loci associated with heart rate from Exome Chip meta-analyses.Heart rate was measured from either elecrtrocardiograms or pulse recordings. We meta-analysed heart rate association results from 104 452 European-ancestry individuals from 30 cohorts, genotyped using the Exome Chip. Twenty-four variants were selected for follow-up in an independent dataset (UK Biobank, N = 134 251). Conditional and gene-based testing was undertaken, and variants were investigated with bioinformatics methods.We discovered five novel heart rate loci, and one new independent low-frequency non-synonymous variant in an established heart rate locus (KIAA1755). Lead variants in four of the novel loci are non-synonymous variants in the genes C10orf71, DALDR3, TESK2 and SEC31B. The variant at SEC31B is significantly associated with SEC31B expression in heart and tibial nerve tissue. Further candidate genes were detected from long-range regulatory chromatin interactions in heart tissue (SCD, SLF2 and MAPK8). We observed significant enrichment in DNase I hypersensitive sites in fetal heart and lung. Moreover, enrichment was seen for the first time in human neuronal progenitor cells (derived from embryonic stem cells) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies. © The Author 2017. Published by Oxford University Press.

  11. 38 CFR 4.119 - Schedule of ratings-endocrine system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., cardiovascular, or astrointestinal symptoms 100 Emotional instability, tachycardia, fatigability, and increased... 10 Note (1): If disease of the heart is the predominant finding, evaluate as hyperthyroid heart disease (DC 7008) if doing so would result in a higher evaluation than using the criteria above. Note (2...

  12. Heart rate and respiratory rhythm dynamics on ascent to high altitude

    NASA Technical Reports Server (NTRS)

    Lipsitz, L. A.; Hashimoto, F.; Lubowsky, L. P.; Mietus, J.; Moody, G. B.; Appenzeller, O.; Goldberger, A. L.

    1995-01-01

    OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P < 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress.

  13. Robust sensor fusion of unobtrusively measured heart rate.

    PubMed

    Wartzek, Tobias; Brüser, Christoph; Walter, Marian; Leonhardt, Steffen

    2014-03-01

    Contactless vital sign measurement technologies often have the drawback of severe motion artifacts and periods in which no signal is available. However, using several identical or physically different sensors, redundancy can be used to decrease the error in noncontact heart rate estimation, while increasing the time period during which reliable data are available. In this paper, we show for the first time two major results in case of contactless heart rate measurements deduced from a capacitive ECG and optical pulse signals. First, an artifact detection is an essential preprocessing step to allow a reliable fusion. Second, the robust but computationally efficient median already provides good results; however, using a Bayesian approach, and a short time estimation of the variance, best results in terms of difference to reference heart rate and temporal coverage can be achieved. In this paper, six sensor signals were used and coverage increased from 0-90% to 80-94%, while the difference between the estimated heart rate and the gold standard was less than ±2 BPM.

  14. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    PubMed

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  15. Spectro-Temporal Electrocardiogram Analysis for Noise-Robust Heart Rate and Heart Rate Variability Measurement

    PubMed Central

    Tobón, Diana P.; Jayaraman, Srinivasan

    2017-01-01

    The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training). PMID:29255653

  16. Ordinal pattern statistics for the assessment of heart rate variability

    NASA Astrophysics Data System (ADS)

    Graff, G.; Graff, B.; Kaczkowska, A.; Makowiec, D.; Amigó, J. M.; Piskorski, J.; Narkiewicz, K.; Guzik, P.

    2013-06-01

    The recognition of all main features of a healthy heart rhythm (the so-called sinus rhythm) is still one of the biggest challenges in contemporary cardiology. Recently the interesting physiological phenomenon of heart rate asymmetry has been observed. This phenomenon is related to unbalanced contributions of heart rate decelerations and accelerations to heart rate variability. In this paper we apply methods based on the concept of ordinal pattern to the analysis of electrocardiograms (inter-peak intervals) of healthy subjects in the supine position. This way we observe new regularities of the heart rhythm related to the distribution of ordinal patterns of lengths 3 and 4.

  17. Heart rate variability alterations in late life depression: A meta-analysis.

    PubMed

    Brown, Lydia; Karmakar, Chandan; Gray, Richard; Jindal, Ripu; Lim, Terrence; Bryant, Christina

    2018-08-01

    There is strong evidence for a bi-directional relationship between heart-health and depression in later life, but the physiological mechanisms underlying this relationship remain unclear. Heart rate variability is one promising factor that might help explain this relationship. We present results of a meta-analysis that considers heart rate variability alterations in older adults with depression. Literature search of Embase, PsychInfo and Medline revealed five clinical studies and six observational studies that examined the relationship between heart rate variability and depression in adults with a mean age over 60. These studies were included in this meta-analysis. Heart rate variability was reduced among older adults with clinical depression (N = 550), relative to healthy controls (Hedges' g = -0.334, 95%CI [-0.579, -0.090], p = .007). When high-frequency and low-frequency heart rate variability were investigated separately, only low-frequency heart rate variability was significantly reduced in depressed patients (Hedges' g = -0.626, 95%CI [-1.083, -0.169], p = .007). A similar but weaker pattern of results was found in the observational studies. Most findings remained significant among unmedicated depressed older adults. Evidence of effect-size heterogeneity was found in the clinical studies, indicating the need for more well-designed research in the area. Heart rate variability is reduced among older adults with depression, and this effect is not fully attributable to antidepressant medication use. Specifically, low-frequency heart rate variability may be reduced in depressed older adults. Heart rate variability warrants further attention, as it could help inform research into the prevention and treatment of depression in later life. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Heart rate and respiratory rhythm dynamics on ascent to high altitude.

    PubMed Central

    Lipsitz, L. A.; Hashimoto, F.; Lubowsky, L. P.; Mietus, J.; Moody, G. B.; Appenzeller, O.; Goldberger, A. L.

    1995-01-01

    OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P < 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress. PMID:7488453

  19. Assessing the Atrial Electromechanical Coupling during Atrial Focal Tachycardia, Flutter, and Fibrillation using Electromechanical Wave Imaging in Humans

    PubMed Central

    Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.

    2015-01-01

    Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338

  20. Heart rate and heart rate variability modification in chronic insomnia patients.

    PubMed

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  1. Effect of alpha-adrenoceptor antagonists (phentolamine, nicergoline and prazosin) on reperfusion arrhythmias and noradrenaline release in perfused rat heart.

    PubMed Central

    Bralet, J.; Didier, J.; Moreau, D.; Opie, L. H.; Rochette, L.

    1985-01-01

    Rat isolated hearts were perfused through the left atrium with a modified Krebs-Henseleit solution or mounted on a Langendorff perfusion system. The hearts were prelabelled with [3H]-noradrenaline [( 3H]-NA) and the left main coronary artery was ligated for 10 min after which reperfusion followed. The liberation of [3H]-NA and the development of ventricular tachycardia and fibrillation were monitored throughout. During the occlusion period, ventricular arrhythmias did not occur and heart rate was not significantly altered in the control series. In contrast, reperfusion was followed by ventricular fibrillation and ventricular tachycardia in all the hearts in the control series (Langendorff or 'working' models). The alpha-adrenoceptor antagonists phentolamine (7.1 X 10(-6) M and 7.1 X 10(-5) M) and nicergoline (3.1 X 10(-6) M) diminished or prevented reperfusion arrhythmias. However, prazosin (5.2 X 10(-6) M) was not effective. The lower concentration of phentolamine did not alter the pattern of [3H]-NA release, whereas, high doses of phentolamine and nicergoline increased the release of [3H]-NA. Prazosin (5.2 X 10(-6) M) caused a very marked increase in release of [3H]-NA but was not antiarrhythmic. A 'membrane-stabilizing' effect seems the most appropriate explanation for these antiarrhythmic effects of alpha-antagonist agents. PMID:2858234

  2. Physiological state characterization by clustering heart rate, heart rate variability and movement activity information.

    PubMed

    Bidargaddi, Niranjan; Sarela, Antti; Korhonen, Ilkka

    2008-01-01

    The objective is to identify whether it is possible to discriminate between normal and abnormal physiological state based on heart rate (HR), heart rate variability (HRV) and movement activity information in subjects with cardiovascular complications. HR, HRV and movement information were obtained from cardiac patients over a period of 6 weeks using an ambulatory activity and single lead ECG monitor. By applying k-means clustering on HR, HRV and movement information obtained from cardiac patients, we obtained 3 clusters in inactive state and one cluster in active state. Two clusters in inactive state characterized by - a) high HR and low HRV b) low HRV and low HR, could be inferred as pathological with abnormal autonomic function. Further, activity information was significant in differentiating between the normal cluster found in active and an abnormal cluster found in inactive states, both with low HRV. This indicates that the activity information must be taken into account while interpreting HR and HRV information.

  3. Ambulatory heart rate range predicts mode-specific mortality and hospitalisation in chronic heart failure

    PubMed Central

    Cubbon, Richard M; Ruff, Naomi; Groves, David; Eleuteri, Antonio; Denby, Christine; Kearney, Lorraine; Ali, Noman; Walker, Andrew M N; Jamil, Haqeel; Gierula, John; Gale, Chris P; Batin, Phillip D; Nolan, James; Shah, Ajay M; Fox, Keith A A; Sapsford, Robert J; Witte, Klaus K; Kearney, Mark T

    2016-01-01

    Objective We aimed to define the prognostic value of the heart rate range during a 24 h period in patients with chronic heart failure (CHF). Methods Prospective observational cohort study of 791 patients with CHF associated with left ventricular systolic dysfunction. Mode-specific mortality and hospitalisation were linked with ambulatory heart rate range (AHRR; calculated as maximum minus minimum heart rate using 24 h Holter monitor data, including paced and non-sinus complexes) in univariate and multivariate analyses. Findings were then corroborated in a validation cohort of 408 patients with CHF with preserved or reduced left ventricular ejection fraction. Results After a mean 4.1 years of follow-up, increasing AHRR was associated with reduced risk of all-cause, sudden, non-cardiovascular and progressive heart failure death in univariate analyses. After accounting for characteristics that differed between groups above and below median AHRR using multivariate analysis, AHRR remained strongly associated with all-cause mortality (HR 0.991/bpm increase in AHRR (95% CI 0.999 to 0.982); p=0.046). AHRR was not associated with the risk of any non-elective hospitalisation, but was associated with heart-failure-related hospitalisation. AHRR was modestly associated with the SD of normal-to-normal beats (R2=0.2; p<0.001) and with peak exercise-test heart rate (R2=0.33; p<0.001). Analysis of the validation cohort revealed AHRR to be associated with all-cause and mode-specific death as described in the derivation cohort. Conclusions AHRR is a novel and readily available prognosticator in patients with CHF, which may reflect autonomic tone and exercise capacity. PMID:26674986

  4. Using Target Heart-Rate Zones in Your Class

    ERIC Educational Resources Information Center

    Gilbert, Jennie A.

    2005-01-01

    Should teachers teach the calculation of target heart rate to students? And when is it appropriate to engage students in the attainment of these heart rates during physical education class activities? The answers to these questions are not easy. One might be tempted to state a simple yes or no and to identify a specific age to begin using training…

  5. Exaggerated heart rate oscillations during two meditation techniques.

    PubMed

    Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L

    1999-07-31

    We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.

  6. Heart rate variability and sympathetic skin response in male patients suffering from acute alcohol withdrawal syndrome.

    PubMed

    Bär, Karl-Jürgen; Boettger, Michael Karl; Neubauer, Rene; Grotelüschen, Marei; Jochum, Thomas; Baier, Vico; Sauer, Heinrich; Voss, Andreas

    2006-09-01

    Many symptoms of alcohol withdrawal (AW) such as tachycardia or elevated blood pressure might be explained by increased peripheral and central adrenergic activity. In contrast to many neurochemical studies of sympathetic activation during AW, only very few studies investigated autonomic balance using neurophysiological methods. We investigated heart rate variability (HRV) and sympathetic skin response (SSR) in male patients suffering from mild AW syndrome (n = 20, no treatment required) and in patients with moderate to severe AW syndrome (n = 20, clomethiazole treatment) in the acute stage. Sympathovagal influence was quantified using measures of time and frequency domain of HRV as well as modern nonlinear parameters (compression entropy). Furthermore, we obtained latencies and amplitudes of SSR to quantify isolated sympathetic influence. Measures were obtained during the climax of withdrawal symptomatology before treatment, 1 day after climax, and shortly before discharge from hospital. Alcohol withdrawal scores were obtained and correlated to autonomic measures. Ambulatory blood pressure and AW scores revealed characteristic withdrawal symptoms in both patient groups. Apart from the nonlinear parameter compression entropy, Hc, measures of HRV revealed no sign of autonomic dysfunction in contrast to the significantly increased heart rates at the time of admission. Latencies and amplitudes of SSR did not indicate any increase of sympathetic activity. A negative correlation was found between Hc and mental withdrawal symptoms. We show here that classical measures for autonomic nervous system activity such as HRV and SSR are not suitable for describing the autonomic changes seen in acute AW, although a major role for the sympathetic nervous system has been proposed. This might be due to multiple dysregulation of metabolites in AWS or to subtle alcohol-induced damage to neuronal structures, issues that should be addressed in future studies.

  7. Association of heart rate profile during exercise with the severity of coronary artery disease.

    PubMed

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6

  8. A randomized controlled trial investigating the effects of craniosacral therapy on pain and heart rate variability in fibromyalgia patients.

    PubMed

    Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen

    2011-01-01

    Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.

  9. Heart Rate Variability During Early Adaptation to Space

    NASA Technical Reports Server (NTRS)

    Toscano, W. B.; Cowings, P. S.

    1994-01-01

    A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.

  10. Randomised controlled trial of intrapartum fetal heart rate monitoring.

    PubMed

    Mahomed, K; Nyoni, R; Mulambo, T; Kasule, J; Jacobus, E

    1994-02-19

    To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. Prospective randomised controlled trial. Referral maternity hospital, Harare, Zimbabwe. 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.

  11. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    PubMed Central

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  12. Intrinsic cardiac nervous system in tachycardia induced heart failure.

    PubMed

    Arora, Rakesh C; Cardinal, Rene; Smith, Frank M; Ardell, Jeffrey L; Dell'Italia, Louis J; Armour, J Andrew

    2003-11-01

    The purpose of this study was to test the hypothesis that early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiac function. After 2 wk of rapid ventricular pacing in nine anesthetized canines, cardiac and right atrial neuronal function were evaluated in situ in response to enhanced cardiac sensory inputs, stimulation of extracardiac autonomic efferent neuronal inputs, and close coronary arterial administration of neurochemicals that included nicotine. Right atrial neuronal intracellular electrophysiological properties were then evaluated in vitro in response to synaptic activation and nicotine. Intrinsic cardiac nicotine-sensitive, neuronally induced cardiac responses were also evaluated in eight sham-operated, unpaced animals. Two weeks of rapid ventricular pacing reduced the cardiac index by 54%. Intrinsic cardiac neurons of paced hearts maintained their cardiac mechano- and chemosensory transduction properties in vivo. They also responded normally to sympathetic and parasympathetic preganglionic efferent neuronal inputs, as well as to locally administered alpha-or beta-adrenergic agonists or angiotensin II. The dose of nicotine needed to modify intrinsic cardiac neurons was 50 times greater in failure compared with normal preparations. That dose failed to alter monitored cardiovascular indexes in failing preparations. Phasic and accommodating neurons identified in vitro displayed altered intracellular membrane properties compared with control, including decreased membrane resistance, indicative of reduced excitability. Early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiodynamics. While maintaining its capacity to transduce cardiac mechano- and chemosensory inputs, as well as inputs from extracardiac autonomic efferent neurons, intrinsic cardiac nicotine-sensitive, local-circuit neurons differentially remodel such that their capacity to

  13. Algorithm for heart rate extraction in a novel wearable acoustic sensor

    PubMed Central

    Imtiaz, Syed Anas; Aguilar–Pelaez, Eduardo; Rodriguez–Villegas, Esther

    2015-01-01

    Phonocardiography is a widely used method of listening to the heart sounds and indicating the presence of cardiac abnormalities. Each heart cycle consists of two major sounds – S1 and S2 – that can be used to determine the heart rate. The conventional method of acoustic signal acquisition involves placing the sound sensor at the chest where this sound is most audible. Presented is a novel algorithm for the detection of S1 and S2 heart sounds and the use of them to extract the heart rate from signals acquired by a small sensor placed at the neck. This algorithm achieves an accuracy of 90.73 and 90.69%, with respect to heart rate value provided by two commercial devices, evaluated on more than 38 h of data acquired from ten different subjects during sleep in a pilot clinical study. This is the largest dataset for acoustic heart sound classification and heart rate extraction in the literature to date. The algorithm in this study used signals from a sensor designed to monitor breathing. This shows that the same sensor and signal can be used to monitor both breathing and heart rate, making it highly useful for long-term wearable vital signs monitoring. PMID:26609401

  14. Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database.

    PubMed

    Lunati, Maurizio; Proclemer, Alessandro; Boriani, Giuseppe; Landolina, Maurizio; Locati, Emanuela; Rordorf, Roberto; Daleffe, Elisabetta; Ricci, Renato Pietro; Catanzariti, Domenico; Tomasi, Luca; Gulizia, Michele; Baccillieri, Maria Stella; Molon, Giulio; Gasparini, Maurizio

    2016-09-01

    Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0-3.5] in Control CRT-D and 0.9% (CI = 0.4-2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21-0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16-0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11-0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1-4.2) in New CRT-D and 3.2 (CI = 2.1-5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2-0.9) in New CRT-D and 0.7 (CI = 0.5-1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6-1.6) in New CRT-D and 3.5 (CI = 3.0-4.1) in Control CRT-D (P < 0.001). Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Bluetooth Heart Rate Monitors For Spaceflight

    NASA Technical Reports Server (NTRS)

    Buxton, R. E.; West, M. R.; Kalogera, K. L.; Hanson, A. M.

    2016-01-01

    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be

  16. Ambulatory heart rate range predicts mode-specific mortality and hospitalisation in chronic heart failure.

    PubMed

    Cubbon, Richard M; Ruff, Naomi; Groves, David; Eleuteri, Antonio; Denby, Christine; Kearney, Lorraine; Ali, Noman; Walker, Andrew M N; Jamil, Haqeel; Gierula, John; Gale, Chris P; Batin, Phillip D; Nolan, James; Shah, Ajay M; Fox, Keith A A; Sapsford, Robert J; Witte, Klaus K; Kearney, Mark T

    2016-02-01

    We aimed to define the prognostic value of the heart rate range during a 24 h period in patients with chronic heart failure (CHF). Prospective observational cohort study of 791 patients with CHF associated with left ventricular systolic dysfunction. Mode-specific mortality and hospitalisation were linked with ambulatory heart rate range (AHRR; calculated as maximum minus minimum heart rate using 24 h Holter monitor data, including paced and non-sinus complexes) in univariate and multivariate analyses. Findings were then corroborated in a validation cohort of 408 patients with CHF with preserved or reduced left ventricular ejection fraction. After a mean 4.1 years of follow-up, increasing AHRR was associated with reduced risk of all-cause, sudden, non-cardiovascular and progressive heart failure death in univariate analyses. After accounting for characteristics that differed between groups above and below median AHRR using multivariate analysis, AHRR remained strongly associated with all-cause mortality (HR 0.991/bpm increase in AHRR (95% CI 0.999 to 0.982); p=0.046). AHRR was not associated with the risk of any non-elective hospitalisation, but was associated with heart-failure-related hospitalisation. AHRR was modestly associated with the SD of normal-to-normal beats (R(2)=0.2; p<0.001) and with peak exercise-test heart rate (R(2)=0.33; p<0.001). Analysis of the validation cohort revealed AHRR to be associated with all-cause and mode-specific death as described in the derivation cohort. AHRR is a novel and readily available prognosticator in patients with CHF, which may reflect autonomic tone and exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Optimizing catecholaminergic polymorphic ventricular tachycardia therapy in calsequestrin-mutant mice

    PubMed Central

    Katz, Guy; Khoury, Assad; Kurtzwald, Efrat; Hochhauser, Edith; Porat, Eyal; Shainberg, Asher; Seidman, Jonathan G.; Seidman, Christine E.; Lorber, Abraham; Eldar, Michael; Arad, Michael

    2014-01-01

    BACKGROUND Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a lethal arrhythmia provoked by physical or emotional stress and mediated by spontaneous Ca2+ release and delayed after-depolarizations. Beta-adrenergic blockers are the therapy of choice but fail to control arrhythmia in up to 50% of patients. OBJECTIVE To optimize antiarrhythmic therapy in recessively inherited CPVT caused by calsequestrin (CASQ2) mutations. METHODS Murine heart rhythm telemetry was obtained at rest, during treadmill exercise, and after injection of epinephrine. The protocol was repeated after injection of different antiarrhythmic drugs. Results were then validated in human patients. RESULTS Adult CASQ2 mutant mice had complex ventricular arrhythmia at rest and developed bidirectional and polymorphic ventricular tachycardia on exertion. Class I antiarrhythmic agents (procainamide, lidocaine, flecainide) were ineffective in controlling arrhythmia. Propranolol and sotalol attenuated arrhythmia at rest but failed to prevent VT during sympathetic stimulation. The calcium channel blocker verapamil showed a dose-dependent protection against CPVT. Verapamil was more effective than the dihydropyridine L-type Ca2+ channel blocker nifedipine, and its activity was markedly enhanced when combined with propranolol. Human patients homozygous for CASQ2D307H mutation, remaining symptomatic despite chronic β-blocker therapy, underwent exercise testing according to the Bruce protocol with continuous electrocardiogram recording. Verapamil was combined with propranolol at maximum tolerated doses. Adding verapamil attenuated ventricular arrhythmia and prolonged exercise duration in five of 11 patients. CONCLUSION Verapamil is highly effective against catecholamine-induced arrhythmia in mice with CASQ2 mutations and may potentiate the antiarrhythmic activity of β-blockers in humans with CPVT2. PMID:20620233

  18. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    USGS Publications Warehouse

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  19. Is the normal heart rate ``chaotic'' due to respiration?

    NASA Astrophysics Data System (ADS)

    Wessel, Niels; Riedl, Maik; Kurths, Jürgen

    2009-06-01

    The incidence of cardiovascular diseases increases with the growth of the human population and an aging society, leading to very high expenses in the public health system. Therefore, it is challenging to develop sophisticated methods in order to improve medical diagnostics. The question whether the normal heart rate is chaotic or not is an attempt to elucidate the underlying mechanisms of cardiovascular dynamics and therefore a highly controversial topical challenge. In this contribution we demonstrate that linear and nonlinear parameters allow us to separate completely the data sets of the three groups provided for this controversial topic in nonlinear dynamics. The question whether these time series are chaotic or not cannot be answered satisfactorily without investigating the underlying mechanisms leading to them. We give an example of the dominant influence of respiration on heart beat dynamics, which shows that observed fluctuations can be mostly explained by respiratory modulations of heart rate and blood pressure (coefficient of determination: 96%). Therefore, we recommend reformulating the following initial question: "Is the normal heart rate chaotic?" We rather ask the following: "Is the normal heart rate `chaotic' due to respiration?"

  20. Heart rate and treatment effect in children with disruptive behavior disorders.

    PubMed

    Stadler, Christina; Grasmann, Dörte; Fegert, Jörg M; Holtmann, Martin; Poustka, Fritz; Schmeck, Klaus

    2008-09-01

    To examine whether children with disruptive behavior disorders (DBDs; hyperkinetic conduct disorder, conduct disorder, hyperkinetic disorder) characterized by low heart rate profit less from an intensive cognitive behavioral intervention aimed at reducing impulsive, oppositional and aggressive behavior problems. Basal heart rate was studied in twenty-three children (aged 7-12 years) with DBD at the beginning of intervention comprising an intensive day-care treatment and parent training. The disruptive behavior of the child was assessed before treatment and after termination (12 weeks later). Therapy responders and non-responders were compared in regard to heart rate and other risk factors (cognitive functioning and socio-economic status). Statistical analyses yielded evidence for a significant reduction of disruptive problem behaviors (aggression, delinquency) that is more prominent in DBD children with high heart rate scores compared to patients with low heart rate scores. Heart rate was significantly lower in children who did not profit from therapy. A logistic regression analysis revealed that heart rate is a significant predictor for therapy success whereas other risk factors had no impact on therapy success. Further studies investigating biological and psychosocial predictors of treatment effectiveness are necessary. In addition, it might be helpful to consider different subtypes of aggressive behavior for selecting the best possible treatment options.

  1. Relation of milrinone after surgery for congenital heart disease to significant postoperative tachyarrhythmias.

    PubMed

    Smith, Andrew H; Owen, Jill; Borgman, Kristie Y; Fish, Frank A; Kannankeril, Prince J

    2011-12-01

    Milrinone reduces the risk of low cardiac output syndrome for some pediatric patients after congenital heart surgery. Data from adults undergoing cardiac surgery suggest an association between milrinone and an increased risk of postoperative arrhythmias. We tested the hypothesis that milrinone is an independent risk factor for tachyarrhythmias after congenital heart surgery. Subjects undergoing congenital heart surgery at our institution were consecutively enrolled for 38 months, through September 2010. The data were prospectively collected, including a review of full-disclosure telemetry and the medical records. Within 38 months, 603 enrolled subjects underwent 724 operative procedures. The median age was 5.5 months (range 0.0 to 426), the median weight was 6.0 kg (range 0.7 to 108), and the cohort was 45% female. The overall arrhythmia incidence was 50%, most commonly monomorphic ventricular tachycardia (n = 85, 12%), junctional ectopic tachycardia (n = 69, 10%), accelerated junctional rhythm (n = 58, 8%), and atrial tachyarrhythmias (including atrial fibrillation, atrial flutter, and ectopic or chaotic atrial tachycardia, n = 58, 8%). Multivariate logistic regression analysis demonstrated that independent of age <1 month, the use of cardiopulmonary bypass, the duration of cardiopulmonary bypass, Risk Adjusted classification for Congenital Heart Surgery, version 1, score >3, and the use of epinephrine or dopamine, milrinone use on admission to the cardiac intensive care unit remained independently associated with an increase in the odds of postoperative tachyarrhythmia resulting in an intervention (odds ratio 2.8, 95% confidence interval 1.3 to 6.0, p = 0.007). In conclusion, milrinone use is an independent risk factor for clinically significant tachyarrhythmias in the early postoperative period after congenital heart surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Caffeine Consumption and Heart Rate and Blood Pressure Response to Regadenoson

    PubMed Central

    Bitar, Abbas; Mastouri, Ronald; Kreutz, Rolf P.

    2015-01-01

    Background Current guidelines recommend that caffeinated products should be avoided for at least 12 hours prior to regadenoson administration. We intended to examine the effect of caffeine consumption and of timing of last dose on hemodynamic effects after regadenoson administration for cardiac stress testing. Methods 332 subjects undergoing regadenoson stress testing were enrolled. Baseline characteristics, habits of coffee/caffeine exposure, baseline vital signs and change in heart rate, blood pressure, percent of maximal predicted heart rate, and percent change in heart rate were prospectively collected. Results Non-coffee drinkers (group 1) (73 subjects) and subjects who last drank coffee >24 hours (group 3) (139 subjects) prior to regadenoson did not demonstrate any difference in systolic blood pressure, heart rate change, maximal predicted heart rate and percent change in heart rate. Systolic blood pressure change (15.2±17.1 vs. 7.2±10.2 mmHg, p = 0.001), heart rate change (32.2±14 vs. 27.3±9.6 bpm, p = 0.038) and maximal predicted heart rate (65.5±15.6 vs. 60.7±8.6%, p = 0.038) were significantly higher in non-coffee drinkers (group 1) compared to those who drank coffee 12–24 hours prior (group 2) (108 subjects). Subjects who drank coffee >24 hours prior (group 3) exhibited higher systolic blood pressure change (13±15.8 vs. 7±10.2, p = 0.007), and heart rate change (32.1±15.3 vs. 27.3±9.6, p = 0.017) as compared to those who drank coffee 12–24 hours prior to testing (group 2). Conclusions Caffeine exposure 12–24 hours prior to regadenoson administration attenuates the vasoactive effects of regadenoson, as evidenced by a blunted rise in heart rate and systolic blood pressure. These results suggest that caffeine exposure within 24 hours may reduce the effects of regadenoson administered for vasodilatory cardiac stress testing. PMID:26098883

  3. Determination of Anaerobic Threshold by Heart Rate or Heart Rate Variability using Discontinuous Cycle Ergometry.

    PubMed

    Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan

    The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.

  4. The effects of baseline heart rate recovery normality and exercise training protocol on heart rate recovery in patients with heart failure.

    PubMed

    Yaylalı, Yalın Tolga; Fındıkoğlu, Gülin; Yurtdaş, Mustafa; Konukçu, Sibel; Şenol, Hande

    2015-09-01

    It is unclear which exercise training protocol yields superior heart rate recovery (HRR) improvement in heart failure (HF) patients. Whether baseline HRR normality plays a role in the improvement is unknown. We hypothesized that an exercise training protocol and baseline HRR normality would be factors in altering HRR in HF patients. In this prospective, randomized, controlled and 3 group parallel study, 41 stable HF patients were randomly assigned to 3-times-weekly training sessions for 12 weeks, consisting of i) 30 minutes of interval training (IT) (n=17, 63.7±8.8 years old) versus ii) 30 minutes of continuous training (CT) (n=13, 59.6±6.8 years old) versus iii) no training (CON) (n=11, 60.6±9.9 years old). Each patient had cardiopulmonary exercise testing before and after the training program. Maximum heart rates attained during the test and heart rates at 1 and 2 min (HRR1 and HRR2) during the recovery phase were recorded. Paired samples t-test or Wilcoxon signed-rank test was used for comparisons before and after training. One-way ANOVA or Kruskal-Wallis variance analysis was used for comparisons among groups. HRR1 was unchanged after training. HRR2 improved in the IT group after training, and post-training HRR2 values were significantly faster in the IT group than in controls. Both HRR1 and HRR2 was significantly faster, irrespective of exercise protocol in patients with abnormal baseline values after training. HRR1 did not improve after training. HRR2 improved only in the IT group. Both HRRs in patients with abnormal baseline values improved after both exercise protocols. IT might be superior to CT in improving HRR2. Baseline HRR might play a role in its response to exercise.

  5. Randomised controlled trial of intrapartum fetal heart rate monitoring.

    PubMed Central

    Mahomed, K.; Nyoni, R.; Mulambo, T.; Kasule, J.; Jacobus, E.

    1994-01-01

    OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources. PMID:8136665

  6. Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

    NASA Technical Reports Server (NTRS)

    Osaka, M.; Saitoh, H.; Sasabe, N.; Atarashi, H.; Katoh, T.; Hayakawa, H.; Cohen, R. J.

    1996-01-01

    Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic

  7. Probability of detection of clinical seizures using heart rate changes.

    PubMed

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (p<0.001) shaped by patients' age and gender, seizure class, and years with epilepsy. The probability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  8. Effects of thyroid hormones on the heart.

    PubMed

    Vargas-Uricoechea, Hernando; Bonelo-Perdomo, Anilsa; Sierra-Torres, Carlos Hernán

    2014-01-01

    Thyroid hormones have a significant impact on heart function, mediated by genomic and non-genomic effects. Consequently, thyroid hormone deficiencies, as well as excesses, are expected to result in profound changes in cardiac function regulation and cardiovascular hemodynamics. Thyroid hormones upregulate the expression of the sarcoplasmic reticulum calcium-activated ATPase and downregulate the expression of phospholamban. Overall, hyperthyroidism is characterized by an increase in resting heart rate, blood volume, stroke volume, myocardial contractility, and ejection fraction. The development of "high-output heart failure" in hyperthyroidism may be due to "tachycardia-mediated cardiomyopathy". On the other hand, in a hypothyroid state, thyroid hormone deficiency results in lower heart rate and weakening of myocardial contraction and relaxation, with prolonged systolic and early diastolic times. Cardiac preload is decreased due to impaired diastolic function. Cardiac afterload is increased, and chronotropic and inotropic functions are reduced. Subclinical thyroid dysfunction is relatively common in patients over 65 years of age. In general, subclinical hypothyroidism increases the risk of coronary heart disease (CHD) mortality and CHD events, but not of total mortality. The risk of CHD mortality and atrial fibrillation (but not other outcomes) in subclinical hyperthyroidism is higher among patients with very low levels of thyrotropin. Finally, medications such as amiodarone may induce hypothyroidism (mediated by the Wolff-Chaikoff), as well as hyperthyroidism (mediated by the Jod-Basedow effect). In both instances, the underlying cause is the high concentration of iodine in this medication. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  9. Association between resting heart rate and arterial stiffness in Korean adults.

    PubMed

    Park, Byoung-Jin; Lee, Hye-Ree; Shim, Jae-Yong; Lee, Jung-Hyun; Jung, Dong-Hyuk; Lee, Yong-Jae

    2010-04-01

    Higher resting heart rate, a simple and useful indicator of autonomic balance and metabolic rate, has emerged as an independent predictor for atherosclerotic cardiovascular disease. To determine the association between resting heart rate and arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV). We examined the association between resting heart rate and baPWV in 641 Korean adults (366 men, 275 women) in a health examination program. A high baPWV was defined as greater than 1450 cm/s (>75th percentile). The odds ratios for high baPWVs were calculated using multivariable logistic regression analysis after adjusting for confounding variables across heart rate quartiles (Q1or=69 beats/min). Age-adjusted baPWV mean values increased gradually with heart rate quartile (Q1=1281, Q2=1285, Q3=1354, Q4=1416 cm/s). The odds ratios (95% confidence intervals) for high baPWVs in each heart rate quartile were 1.00, 1.28 (0.57-2.86), 2.63 (1.20-5.79) and 3.66 (1.66-8.05), respectively, after adjusting for age, sex, smoking status, alcohol intake, exercise, body mass index, hypertension medication, diabetes medication, hyperlipidaemia medication, mean arterial blood pressure, fasting plasma glucose, total cholesterol, triglycerides, high-density lipoprotein cholesterol, white blood cell count, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyltransferase and uric acid. These findings indicate that a higher resting heart rate is independently associated with arterial stiffness. Accordingly, early detection of increased resting heart rate is important for preservation of arterial function and assessment of cardiovascular risk. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  10. Maternal exercise, season and sex modify the daily fetal heart rate rhythm.

    PubMed

    Sletten, J; Cornelissen, G; Assmus, J; Kiserud, T; Albrechtsen, S; Kessler, J

    2018-05-13

    The knowledge on biological rhythms is rapidly expanding. We aimed to define the longitudinal development of the daily (24-hour) fetal heart rate rhythm in an unrestricted, out-of-hospital setting and to examine the effects of maternal physical activity, season and fetal sex. We recruited 48 women with low-risk singleton pregnancies. Using a portable monitor for continuous fetal electrocardiography, fetal heart rate recordings were obtained around gestational weeks 24, 28, 32 and 36. Daily rhythms in fetal heart rate and fetal heart rate variation were detected by cosinor analysis; developmental trends were calculated by population-mean cosinor and multilevel analysis. For the fetal heart rate and fetal heart rate variation, a significant daily rhythm was present in 122/123 (99.2%) and 116/121 (95.9%) of the individual recordings respectively. The rhythms were best described by combining cosine waves with periods of 24 and 8 hours. With increasing gestational age, the magnitude of the fetal heart rate rhythm increased, and the peak of the fetal heart rate variation rhythm shifted from a mean of 14:25 (24 weeks) to 20:52 (36 weeks). With advancing gestation, the rhythm-adjusted mean value of the fetal heart rate decreased linearly in females (P < .001) and nonlinearly in males (quadratic function, P = .001). At 32 and 36 weeks, interindividual rhythm diversity was found in male fetuses during higher maternal physical activity and during the summer season. The dynamic development of the daily fetal heart rate rhythm during the second half of pregnancy is modified by fetal sex, maternal physical activity and season. © 2018 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  11. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    PubMed Central

    Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave). PMID:27826247

  12. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    PubMed

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  13. The effect of respiratory oscillations in heart rate on detrended fluctuation analysis

    NASA Astrophysics Data System (ADS)

    Govindan, Rathinaswamy B.; Kota, Srinivas; Al-Shargabi, Tareq; Swisher, Christopher B.; du Plessis, Adre

    2017-10-01

    Characterization of heart rate using detrended fluctuation analysis (DFA) is impeded by respiratory oscillations. In particular, the short-term exponent measured from 15 to 30 beats is compromised in the DFA. We reconstruct respiratory signal from electrocardiograms and attenuate the respiratory oscillation in the heart rate using a frequency-dependent subtraction approach. We validate this method by applying it to an electrocardiogram signal simulated using a coupled differential equation with the respiratory oscillation modelled using a sine function. The exponent estimated using the proposed approach agreed with the exponent incorporated in the model within a narrow range. In contrast, the exponent obtained from the raw data deviated from the expected value. Furthermore, the exponents obtained for the raw heart rate are smaller than the exponents obtained for the respiration oscillation attenuated heart rate. We apply this approach to heart rate measured from 12 preterm infants that were being treated for prematurity related complications. As observed in the simulated data, we show that compared to the raw heart rate, the respiratory oscillation attenuated heart rate shows higher short-term exponent (p < 0.001).

  14. Relation of Milrinone Following Surgery for Congenital Heart Disease to Significant Postoperative Tachyarrhythmias

    PubMed Central

    Smith, Andrew H.; Owen, Jill; Borgman, Kristie Y.; Fish, Frank A.; Kannankeril, Prince J.

    2011-01-01

    Milrinone reduces the risk of low cardiac output syndrome for some pediatric patients following congenital heart surgery. Data from adults undergoing cardiac surgery suggest an association between milrinone and increased risk for postoperative arrhythmias. We tested the hypothesis that milrinone is an independent risk factor for tachyarrhythmias following congenital heart surgery. Subjects undergoing congenital heart surgery at our institution were consecutively enrolled for 38 months, through September 2010. Data was prospectively collected, including review of full-disclosure telemetry and the medical record. Over 38 months, 603 enrolled subjects underwent 724 operative procedures. The median age was 5.5 months (0.0–426), weight was 6.0 kg (0.7–108), and the cohort was 45% female. Overall arrhythmia incidence was 50%, most commonly monomorphic ventricular tachycardia (n=85, 12%), junctional ectopic tachycardia (n=69, 10%), accelerated junctional rhythm (n=58, 8%), and atrial tachyarrhythmias (including atrial fibrillation, atrial flutter, and ectopic or chaotic atrial tachycardia, n=58, 8%). Multivariate logistic regression analysis demonstrated that independent of age less than 1 month, use of cardiopulmonary bypass, duration of cardiopulmonary bypass, RACHS-1 score greater than 3, and the use of epinephrine or dopamine, milrinone use on admission to the cardiac intensive care unit remained independently associated with an increase in the odds of postoperative tachyarrhythmia resulting in an intervention (OR 2.8 [95%CI 1.3–6.0], p=0.007). In conclusion, milrinone use is an independent risk factor for clinically significant tachyarrhythmias in the early postoperative period following congenital heart surgery. PMID:21890079

  15. Heart rate variability in newborns.

    PubMed

    Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M

    2017-09-22

    Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.

  16. Heart rate and physical activity patterns in persons with profound intellectual and multiple disabilities.

    PubMed

    Waninge, Aly; van der Putten, Annette A J; Stewart, Roy E; Steenbergen, Bert; van Wijck, Ruud; van der Schans, Cees P

    2013-11-01

    Because physical fitness and health are related to physical activity, it is important to gain an insight into the physical activity levels of persons with profound intellectual and multiple disabilities (PIMD). The purpose of this study was to examine heart rate patterns to measure the activity levels of persons with PIMD and to analyze these heart rate patterns according to participant characteristics, observed level of activity, days, and time of day. The heart rate patterns of 24 participants with PIMD were measured continuously using a heart rate monitor for 8 h · d for a period of 6 days. Physical activity levels were measured with questionnaires. Data were analyzed using multilevel analysis. The results indicate that the participants use only 32% of their heart rate reserve over 6 days. The intensity of heart rate reserve ranged from 1 to 62%. On a given day, wide ranges in heart rates between participants and within persons were observed. Between days, only small ranges in the heart rate were found. The participants could be grouped into 4 classes according to their heart rate. In addition, factors such as time of day, physical activity, and age are significantly related to heart rate patterns. In conclusion, this study is an important first step in exploring activity patterns based on heart rate patterns in persons with PIMD. The participants used relatively small fractions of their heart rate reserves. Time of day and age appear to have a considerable influence on heart rate patterns. The observed classes in heart rate patterns suggest that other probably more personal and psychosocial factors have significant influences on heart rate patterns, as well.

  17. Quantification of fetal heart rate regularity using symbolic dynamics

    NASA Astrophysics Data System (ADS)

    van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.

    2007-03-01

    Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to

  18. A Prospective Study of Ripple Mapping the Post-Infarct Ventricular Scar to Guide Substrate Ablation for Ventricular Tachycardia.

    PubMed

    Luther, Vishal; Linton, Nick W F; Jamil-Copley, Shahnaz; Koa-Wing, Michael; Lim, Phang Boon; Qureshi, Norman; Ng, Fu Siong; Hayat, Sajad; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2016-06-01

    Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (<1.5 mV) occupied a median 29% of the total surface area (median 540 points collected within scar). A median of 2 ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation. © 2016 American Heart Association

  19. Introducing a novel mechanism to control heart rate in the ancestral Pacific hagfish.

    PubMed

    Wilson, Christopher M; Roa, Jinae N; Cox, Georgina K; Tresguerres, Martin; Farrell, Anthony P

    2016-10-15

    Although neural modulation of heart rate is well established among chordate animals, the Pacific hagfish (Eptatretus stoutii) lacks any cardiac innervation, yet it can increase its heart rate from the steady, depressed heart rate seen in prolonged anoxia to almost double its normal normoxic heart rate, an almost fourfold overall change during the 1-h recovery from anoxia. The present study sought mechanistic explanations for these regulatory changes in heart rate. We provide evidence for a bicarbonate-activated, soluble adenylyl cyclase (sAC)-dependent mechanism to control heart rate, a mechanism never previously implicated in chordate cardiac control. © 2016. Published by The Company of Biologists Ltd.

  20. Diminution of Heart Rate Variability in Bipolar Depression

    PubMed Central

    Hage, Brandon; Britton, Briana; Daniels, David; Heilman, Keri; Porges, Stephen W.; Halaris, Angelos

    2017-01-01

    Autonomic nervous system (ANS) dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV) provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD) patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia) was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20) than controls (ln = 5.50) (p < 0.01). Baseline heart period was significantly shorter (i.e., faster heart rate) in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients. PMID:29270399

  1. Power spectral analysis of heart rate in hyperthyroidism.

    PubMed

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P < 0.01); standing, 6.0 +/- 2.7 vs. 15.0 +/- 4.0 NU (P < 0.01); mean +/- SEM]. On the other hand components were comparable in the 2 groups (lying, 64.0 +/- 6.9 vs. 62.0 +/- 6.5 NU; standing, 77.0 +/- 6.5 vs. 78.0 +/- 5.4 NU). Hence, the LF/HF ratio, which is considered an index of sympathovagal balance, was increased in hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P < 0.05) and standing (54.0 +/- 12.6 vs. 9.8 +/- 2.6; P < 0.02). This parameter was positively correlated with both T3 (r = 0.61; P < 0.05) and free T4 (r = 0.63; P < 0.05) serum levels. Among traditional cardiovascular autonomic tests, the reflex response of heart rate during lying to standing was significantly lower in hyperthyroid patients than in controls (1

  2. Effect of uterine contractions on fetal heart rate in pregnancy: a prospective observational study.

    PubMed

    Sletten, Julie; Kiserud, Torvid; Kessler, Jörg

    2016-10-01

    The new Holter monitoring technology enables long-term electrocardiographic recording of the fetal heart rate without discomfort for the mother. The aim of the study was to assess the feasibility of a fetal Holter monitor. This technology was further used to study fetal heart rate outside the hospital setting during normal daily activities and to test the hypothesis that uterine activity during pregnancy influences fetal heart rate. Prospective observational study including 12 healthy pregnant women at 20-40 weeks of gestation. Data were collected using the Monica AN24 system. Outcome measures were fetal heart rate, maternal heart rate, and uterine activity categorized according to the strength of the electrohysterographic signal. The recordings had a median length of 18.8 h, and fetal heart rate and maternal heart rate were obtained with success rates of 73.1 and 99.9%, respectively. Uterine activity was found to affect fetal heart rate in all participants. Compared with the basal tone and mild levels of uterine activity, moderate and strong levels of uterine activity were associated with increases in fetal heart rate of 4.0 and 5.7 beats/min, respectively. At night, the corresponding increases were 4.9 and 7.6 beats/min. Linear correlations were found between maternal heart rate and fetal heart rate in 11 of the 12 cases, with a mean coefficient beta of 0.189. Both maternal heart rate and fetal heart rate exhibited a diurnal pattern, with lower heart rates being recorded at night. Uterine activity during pregnancy is associated with a graded response in fetal heart rate and may represent a physiological challenge for the development and adaptation of the fetal cardiovascular system. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  3. Evaluation of Dry Electrodes in Canine Heart Rate Monitoring.

    PubMed

    Virtanen, Juhani; Somppi, Sanni; Törnqvist, Heini; Jeyhani, Vala; Fiedler, Patrique; Gizatdinova, Yulia; Majaranta, Päivi; Väätäjä, Heli; Valldeoriola Cardó, Anna; Lekkala, Jukka; Tuukkanen, Sampo; Surakka, Veikko; Vainio, Outi; Vehkaoja, Antti

    2018-05-30

    The functionality of three dry electrocardiogram electrode constructions was evaluated by measuring canine heart rate during four different behaviors: Standing, sitting, lying and walking. The testing was repeated (n = 9) in each of the 36 scenarios with three dogs. Two of the electrodes were constructed with spring-loaded test pins while the third electrode was a molded polymer electrode with Ag/AgCl coating. During the measurement, a specifically designed harness was used to attach the electrodes to the dogs. The performance of the electrodes was evaluated and compared in terms of heartbeat detection coverage. The effect on the respective heart rate coverage was studied by computing the heart rate coverage from the measured electrocardiogram signal using a pattern-matching algorithm to extract the R-peaks and further the beat-to-beat heart rate. The results show that the overall coverage ratios regarding the electrodes varied between 45⁻95% in four different activity modes. The lowest coverage was for lying and walking and the highest was for standing and sitting.

  4. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    PubMed

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P < 0.001. There were no such differences for turbulence slope (Ts). In the 24-hour analysis almost all heart rate variability parameters were significantly lower in the systemic lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R

  5. Lack of correlation between canine heart rate and body size in veterinary clinical practice.

    PubMed

    Ferasin, L; Ferasin, H; Little, C J L

    2010-08-01

    An association between heart rate (HR) and bodyweight has been reported in dogs and it is common belief that small breeds of dog exhibit higher HR than large breeds. The first aim of this study was to test the null hypothesis that, in veterinary clinical practice, bodyweight does not affect HR measured in healthy dogs. A second objective of this investigation was to assess whether other variables, such as gender, breed morphology, age and demeanour, may have a significant effect on dog's HR measured in a clinical setting. The investigation was performed via two different studies: a retrospective analysis performed on 243 electrocardiogram recordings and a prospective study based on 153 standardised clinical examinations. The two separate studies did not show any significant correlation between HR and bodyweight (P=0.5705 and P=0.4682, respectively). Subject's breed morphology and gender did not appear to affect HR measured under these circumstances. However, dogs under the age of one year seem to have significantly higher HRs than older dogs (P < 0.05). Finally, subject's demeanour was also found to have a significant influence on HR; lower values were recorded in relaxed dogs, and higher rates were documented in excited, nervous dogs (P < 0.05). Normal HR could be erroneously interpreted as bradycardia or tachycardia if bodyweight was to be considered a determinant factor. Instead, HR in healthy dogs undergoing routine clinical examination is related to their demeanour or age, if younger than 12 months, but does not appear to be related to bodyweight.

  6. RyR2R420Q catecholaminergic polymorphic ventricular tachycardia mutation induces bradycardia by disturbing the coupled clock pacemaker mechanism

    PubMed Central

    Wang, Yue Yi; Mesirca, Pietro; Marqués-Sulé, Elena; Villejoubert, Olivier; D’Ocon, Pilar; Ruiz, Cristina; Domingo, Diana; Zorio, Esther; Mangoni, Matteo E.; Benitah, Jean-Pierre; Gómez, Ana María

    2017-01-01

    Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a lethal genetic arrhythmia that manifests syncope or sudden death in children and young adults under stress conditions. CPVT patients often present bradycardia and sino-atrial node (SAN) dysfunction. However, the mechanism remains unclear. We analyzed SAN function in two CPVT families and in a novel knock-in (KI) mouse model carrying the RyR2R420Q mutation. Humans and KI mice presented slower resting heart rate. Accordingly, the rate of spontaneous intracellular Ca2+ ([Ca2+]i) transients was slower in KI mouse SAN preparations than in WT, without any significant alteration in the “funny” current (If ). The L-type Ca2+ current was reduced in KI SAN cells in a [Ca2+]i-dependent way, suggesting that bradycardia was due to disrupted crosstalk between the “voltage” and “Ca2+” clock, and the mechanisms of pacemaking was induced by aberrant spontaneous RyR2- dependent Ca2+ release. This finding was consistent with a higher Ca2+ leak during diastolic periods produced by long-lasting Ca2+ sparks in KI SAN cells. Our results uncover a mechanism for the CPVT-causing RyR2 N-terminal mutation R420Q, and they highlight the fact that enhancing the Ca2+ clock may slow the heart rhythm by disturbing the coupling between Ca2+ and voltage clocks. PMID:28422759

  7. Effects of acute hyperthermia on the carotid baroreflex control of heart rate in humans

    NASA Astrophysics Data System (ADS)

    Yamazaki, F.; Sagawa, S.; Torii, R.; Endo, Y.; Shiraki, K.

    The purpose of this study was to examine the effect of hyperthermia on the carotid baroreceptor-cardiac reflexes in humans. Nine healthy males underwent acute hyperthermia (esophageal temperature 38.0° C) produced by hot water-perfused suits. Beat-to-beat heart rate (HR) responses were determined during positive and negative R-wave-triggered neck pressure steps from +40 to -65 mm Hg during normothermia and hyperthermia. The carotid baroreceptor-cardiac reflex sensitivity was evaluated from the maximum slope of the HR response to changes in carotid distending pressure. Buffering capacity of the HR response to carotid distending pressure was evaluated in % from a reference point calculated as (HR at 0 mm Hg neck pressure-minimum HR)/HR range ×100. An upward shift of the curve was evident in hyperthermia because HR increased from 57.7+/-2.4 beats/min in normothermia to 88.7+/-4.1 beats/min in hyperthermia (P<0.05) without changes in mean arterial pressure. The maximum slope of the curve in hyperthermia was similar to that in normothermia. The reference point was increased (P<0.05) during hyperthermia. These results suggest that the sensitivity of the carotid baroreflex of HR remains unchanged in hyperthermia. However, the capacity for tachycardia response to rapid onset of hypotension is reduced and the capacity for bradycardia response to sudden hypertension is increased during acute hyperthermia.

  8. Food composition influences metabolism, heart rate and organ growth during digestion in Python regius.

    PubMed

    Henriksen, Poul Secher; Enok, Sanne; Overgaard, Johannes; Wang, Tobias

    2015-05-01

    Digestion in pythons is associated with a large increase in oxygen consumption (SDA), increased cardiac output and growth in visceral organs assisting in digestion. The processes leading to the large postprandial rise in metabolism in snakes is subject to opposing views. Gastric work, protein synthesis and organ growth have each been speculated to be major contributors to the SDA. To investigate the role of food composition on SDA, heart rate (HR) and organ growth, 48 ball pythons (Python regius) were fed meals of either fat, glucose, protein or protein combined with carbonate. Our study shows that protein, in the absence or presence of carbonate causes a large SDA response, while glucose caused a significantly smaller SDA response and digestion of fat failed to affect metabolism. Addition of carbonate to the diet to stimulate gastric acid secretion did not increase the SDA response. These results support protein synthesis as a major contributor to the SDA response and show that increased gastric acid secretion occurs at a low metabolic cost. The increase in metabolism was supported by tachycardia caused by altered autonomic regulation as well as an increased non-adrenergic, non-cholinergic (NANC) tone in response to all diets, except for the lipid meal. Organ growth only occurred in the small intestine and liver in snakes fed on a high protein diet. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Computerized analysis of the 12-lead electrocardiogram to identify epicardial ventricular tachycardia exit sites.

    PubMed

    Yokokawa, Miki; Jung, Dae Yon; Joseph, Kim K; Hero, Alfred O; Morady, Fred; Bogun, Frank

    2014-11-01

    Twelve-lead electrocardiogram (ECG) criteria for epicardial ventricular tachycardia (VT) origins have been described. In patients with structural heart disease, the ability to predict an epicardial origin based on QRS morphology is limited and has been investigated only for limited regions in the heart. The purpose of this study was to determine whether a computerized algorithm is able to accurately differentiate epicardial vs endocardial origins of ventricular arrhythmias. Endocardial and epicardial pace-mapping were performed in 43 patients at 3277 sites. The 12-lead ECGs were digitized and analyzed using a mixture of gaussian model (MoG) to assess whether the algorithm was able to identify an epicardial vs endocardial origin of the paced rhythm. The MoG computerized algorithm was compared to algorithms published in prior reports. The computerized algorithm correctly differentiated epicardial vs endocardial pacing sites for 80% of the sites compared to an accuracy of 42% to 66% of other described criteria. The accuracy was higher in patients without structural heart disease than in those with structural heart disease (94% vs 80%, P = .0004) and for right bundle branch block (82%) compared to left bundle branch block morphologies (79%, P = .001). Validation studies showed the accuracy for VT exit sites to be 84%. A computerized algorithm was able to accurately differentiate the majority of epicardial vs endocardial pace-mapping sites. The algorithm is not region specific and performed best in patients without structural heart disease and with VTs having a right bundle branch block morphology. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Heart-Rate Recovery Index Is Impaired in Behçet's Disease

    PubMed Central

    Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali

    2009-01-01

    Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299

  11. Heart rate at baseline influences the effect of ivabradine on cardiovascular outcomes in chronic heart failure: analysis from the SHIFT study.

    PubMed

    Böhm, Michael; Borer, Jeffrey; Ford, Ian; Gonzalez-Juanatey, Jose R; Komajda, Michel; Lopez-Sendon, Jose; Reil, Jan-Christian; Swedberg, Karl; Tavazzi, Luigi

    2013-01-01

    We analysed the effect of ivabradine on outcomes in heart failure (HF) patients on recommended background therapies with heart rates ≥75 bpm and <75 bpm in the SHIFT trial. A cut-off value of ≥75 bpm was chosen by the EMEA for approval for the use of ivabradine in chronic heart failure. The SHIFT population was divided by baseline heart rate ≥75 or <75 bpm. The effect of ivabradine was analysed for primary composite endpoint (cardiovascular death or HF hospitalization) and other endpoints. In the ≥75 bpm group, ivabradine reduced primary endpoint (HR 0.76, 95 % CI 0.68-0.85, P < 0.0001), all-cause mortality (HR 0.83, 95 % CI, 0.72-0.96, P = 0.0109), cardiovascular mortality (HR 0.83, 95 % CI, (0.71-0.97, P = 0.0166), HF death (HR 0.61, 95 % CI, 0.46-0.81, P < 0.0006), and HF hospitalization (HR 0.70, 95 % CI, 0.61-0.80, P < 0.0001). Risk reduction depended on heart rate after 28 days, with the best protection for heart rates <60 bpm or reductions >10 bpm. None of the endpoints was significantly reduced in the <75 bpm group, though there were trends for risk reductions in HF death and hospitalization for heart rate <60 bpm and reductions >10 bpm. Ivabradine was tolerated similarly in both groups. The effect of ivabradine on outcomes is greater in patients with heart rate ≥75 bpm with heart rates achieved <60 bpm or heart rate reductions >10 bpm predicting best risk reduction. Our findings emphasize the importance of identification of high-risk HF patients by high heart rates and their treatment with heart rate-lowering drugs such as ivabradine.

  12. Opportunity for information search and the effect of false heart rate feedback.

    PubMed

    Barefoot, John C; Straub, Ronald B

    2005-01-01

    The role of information search in the attribution of physiological states was investigated by manipulating the subject's opportunity for information search following the presentation of false information about his heart-rate reactions to photographs of female nudes. Consistent with the self-persuasion hypothesis proposed by Valins, the rated attractiveness of the slides was not affected by the false heart-rate feedback for those subjects who were prevented from visually searching the slides. Those subjects who had ample opportunity to view the slides rated those slides accompanied by false information of a heart-rate change as more attractive than those slides which were not paired with a change in heart rate.

  13. Heart rate measurement as a tool to quantify sedentary behavior.

    PubMed

    Åkerberg, Anna; Koshmak, Gregory; Johansson, Anders; Lindén, Maria

    2015-01-01

    Sedentary work is very common today. The aim of this pilot study was to attempt to differentiate between typical work situations and to investigate the possibility to break sedentary behavior, based on physiological measurement among office workers. Ten test persons used one heart rate based activity monitor (Linkura), one pulse oximeter device (Wrist) and one movement based activity wristband (Fitbit Flex), in different working situations. The results showed that both heart rate devices, Linkura and Wrist, were able to detect differences in heart rate between the different working situations (resting, sitting, standing, slow walk and medium fast walk). The movement based device, Fitbit Flex, was only able to separate differences in steps between slow walk and medium fast walk. It can be concluded that heart rate measurement is a promising tool for quantifying and separating different working situations, such as sitting, standing and walking.

  14. Comparison of heart rate variability and pulse rate variability detected with photoplethysmography

    NASA Astrophysics Data System (ADS)

    Rauh, Robert; Limley, Robert; Bauer, Rainer-Dieter; Radespiel-Troger, Martin; Mueck-Weymann, Michael

    2004-08-01

    This study compares ear photoplethysmography (PPG) and electrocardiogram (ECG) in providing accurate heart beat intervals for use in calculations of heart rate variability (HRV, from ECG) or of pulse rate variability (PRV, from PPG) respectively. Simultaneous measurements were taken from 44 healthy subjects at rest during spontaneous breathing and during forced metronomic breathing (6/min). Under both conditions, highly significant (p > 0.001) correlations (1.0 > r > 0.97) were found between all evaluated common HRV and PRV parameters. However, under both conditions the PRV parameters were higher than HRV. In addition, we calculated the limits of agreement according to Bland and Altman between both techniques and found good agreement (< 10% difference) for heart rate and standard deviation of normal-to-normal intervals (SDNN), but only moderate (10-20%) or even insufficient (> 20%) agreement for other standard HRV and PRV parameters. Thus, PRV data seem to be acceptable for screening purposes but, at least at this state of knowledge, not for medical decision making. However, further studies are needed before more certain determination can be made.

  15. [Catheter ablation of ectopic incessant atrial tachycardia using radiofrequency. Reversion of tachycardiomyopathy].

    PubMed

    de Paola, A A; Mendonça, A; Balbão, C E; Tavora, M Z; da Silva, R M; Hara, V M; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-10-01

    A 8-year-old female patient with refractory incessant atrial tachycardia, very symptomatic and with left ventricular ejection fraction of 0.25. Electrophysiological study and endocardial mapping localized the site of the origin of atrial tachycardia in the superior right atrium. In this site 2 applications of radiofrequency current (25V, 20 and 50 seconds) resulted in termination of the atrial tachycardia. She was discharged off antiarrhythmic drugs and after 2 months ejection fraction was 0.52. She was completely asymptomatic 6 months after ablation procedure.

  16. [The influence of physical exercise on heart rate variability].

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  17. Heart rate and outcomes in patients with heart failure with preserved ejection fraction: A dose-response meta-analysis.

    PubMed

    Shang, Xiaoke; Lu, Rong; Liu, Mei; Xiao, Shuna; Dong, Nianguo

    2017-10-01

    Although elevated resting heart rate is related to poor outcomes in heart failure (HF) with reduced ejection fraction, the association in HF with preserved ejection fraction (HFpEF) remains inconclusive. Therefore, we conducted a dose-response meta-analysis to examine the prognostic role of heart rate in patients with HFpEF.We searched PubMed and Embase databases until April 2017 and manually reviewed the reference lists of relevant literatures. Random effect models were used to pool the study-specific hazard ratio (HR) of outcomes, including all-cause death, cardiovascular death, and HF hospitalization.Six studies with 7 reports were finally included, totaling 14,054 patients with HFpEF. The summary HR (95% confidence interval [CI]) for every 10 beats/minute increment in heart rate was 1.04 (1.02-1.06) for all-cause death, 1.06 (1.02-1.10) for cardiovascular death, and 1.05 (1.01-1.08) for HF hospitalization. Subgroup analyses indicated that these positive relationships were significant in patients with sinus rhythm but not in those with atrial fibrillation. There was also evidence for nonlinear relationship of heart rate with each of the outcomes (All P for nonlinearity < .05).Higher heart rate in sinus rhythm is a risk factor for adverse outcomes in patients with HFpEF. Future trials are required to determine whether heart rate reduction may improve the prognosis of HFpEF.

  18. Can heart rate predict blood pressure response to anti-hypertensive drug therapy?

    PubMed

    Owens, P E; Lyons, S; O'Brien, E

    1998-04-01

    The use of heart rate in clinical practice is limited by its variability under measurement situations. The mean heart rate on ambulatory monitoring provides a more robust statistic for clinical use. We examined the relationship between mean heart rate on initial referral ambulatory blood pressure monitoring (ABPM) to the BP-lowering efficacy of the four main groups of anti-hypertensive medications, in a referral hypertensive population. Patients were retrospectively identified by review of the BP database, and data collected from the initial referral BP monitor off medication, and the subsequent ABPM after treatment with either beta-blockers, diuretics, calcium antagonists or angiotensin-converting enzyme (ACE) inhibitors. The change in mean arterial BP from the initial to the subsequent ABPM (ie, as a result of treatment) was correlated with the mean heart rate on the initial ABPM. A moderate association was found for initial daytime heart rate and BP response to beta-blockers (r = 0.24, P = 0.02), and ACE inhibitors (r = 0.14, P = 0.05). No such association was found for calcium antagonists or diuretics. When the groups were divided into those with a mean daytime heart rate <75 and > or =75 beats per min, BP reduction from beta-blocker and ACE inhibitor therapy was significantly greater in those patients with a higher daytime heart rate. We conclude that average daytime heart rate on pre-treatment ABPM can be useful as a predictor of BP response to beta-blockade or ACE inhibition.

  19. Voluntary control of breathing does not alter vagal modulation of heart rate

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.

    1995-01-01

    Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

  20. Effects of acute hypoxia on the determination of anaerobic threshold using the heart rate-work rate relationships during incremental exercise tests.

    PubMed

    Ozcelik, O; Kelestimur, H

    2004-01-01

    Anaerobic threshold which describes the onset of systematic increase in blood lactate concentration is a widely used concept in clinical and sports medicine. A deflection point between heart rate-work rate has been introduced to determine the anaerobic threshold non-invasively. However, some researchers have consistently reported a heart rate deflection at higher work rates, while others have not. The present study was designed to investigate whether the heart rate deflection point accurately predicts the anaerobic threshold under the condition of acute hypoxia. Eight untrained males performed two incremental exercise tests using an electromagnetically braked cycle ergometer: one breathing room air and one breathing 12 % O2. The anaerobic threshold was estimated using the V-slope method and determined from the increase in blood lactate and the decrease in standard bicarbonate concentration. This threshold was also estimated by in the heart rate-work rate relationship. Not all subjects exhibited a heart rate deflection. Only two subjects in the control and four subjects in the hypoxia groups showed a heart rate deflection. Additionally, the heart rate deflection point overestimated the anaerobic threshold. In conclusion, the heart rate deflection point was not an accurate predictor of anaerobic threshold and acute hypoxia did not systematically affect the heart rate-work rate relationships.

  1. Automatic Vagus Nerve Stimulation Triggered by Ictal Tachycardia: Clinical Outcomes and Device Performance--The U.S. E-37 Trial.

    PubMed

    Fisher, Robert S; Afra, Pegah; Macken, Micheal; Minecan, Daniela N; Bagić, Anto; Benbadis, Selim R; Helmers, Sandra L; Sinha, Saurabh R; Slater, Jeremy; Treiman, David; Begnaud, Jason; Raman, Pradheep; Najimipour, Bita

    2016-02-01

    The Automatic Stimulation Mode (AutoStim) feature of the Model 106 Vagus Nerve Stimulation (VNS) Therapy System stimulates the left vagus nerve on detecting tachycardia. This study evaluates performance, safety of the AutoStim feature during a 3-5-day Epilepsy Monitoring Unit (EMU) stay and long- term clinical outcomes of the device stimulating in all modes. The E-37 protocol (NCT01846741) was a prospective, unblinded, U.S. multisite study of the AspireSR(®) in subjects with drug-resistant partial onset seizures and history of ictal tachycardia. VNS Normal and Magnet Modes stimulation were present at all times except during the EMU stay. Outpatient visits at 3, 6, and 12 months tracked seizure frequency, severity, quality of life, and adverse events. Twenty implanted subjects (ages 21-69) experienced 89 seizures in the EMU. 28/38 (73.7%) of complex partial and secondarily generalized seizures exhibited ≥20% increase in heart rate change. 31/89 (34.8%) of seizures were treated by Automatic Stimulation on detection; 19/31 (61.3%) seizures ended during the stimulation with a median time from stimulation onset to seizure end of 35 sec. Mean duty cycle at six-months increased from 11% to 16%. At 12 months, quality of life and seizure severity scores improved, and responder rate was 50%. Common adverse events were dysphonia (n = 7), convulsion (n = 6), and oropharyngeal pain (n = 3). The Model 106 performed as intended in the study population, was well tolerated and associated with clinical improvement from baseline. The study design did not allow determination of which factors were responsible for improvements. © 2015 The Authors. Neuromodulation: Technology at the Neural Interface published by Wiley Periodicals, Inc. on behalf of International Neuromodulation Society.

  2. AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS

    PubMed Central

    Báez, San Martín E.; Von Oetinger, A.; Cañas, Jamett R.; Ramírez, Campillo R.

    2013-01-01

    The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW). A total of 18 male athletes were evaluated, ten highly trained (HT) and eight moderately trained (MT), who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s), and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1) analysis of heart rate variability (HRV), using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s). Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05) and in the non linear analysis of HRV from SD130-45s (p <0.05) and SD145-60s (p <0.05). The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW. PMID:24744476

  3. Autonomic control of heart rate after exercise in trained wrestlers.

    PubMed

    Henríquez, Olguín C; Báez, San Martín E; Von Oetinger, A; Cañas, Jamett R; Ramírez, Campillo R

    2013-06-01

    The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW). A total of 18 male athletes were evaluated, ten highly trained (HT) and eight moderately trained (MT), who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s), and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability - SD1) analysis of heart rate variability (HRV), using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s). Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05) and in the non linear analysis of HRV from SD130-45s (p <0.05) and SD145-60s (p <0.05). The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.

  4. Sensor fusion methods for reducing false alarms in heart rate monitoring.

    PubMed

    Borges, Gabriel; Brusamarello, Valner

    2016-12-01

    Automatic patient monitoring is an essential resource in hospitals for good health care management. While alarms caused by abnormal physiological conditions are important for the delivery of fast treatment, they can be also a source of unnecessary noise because of false alarms caused by electromagnetic interference or motion artifacts. One significant source of false alarms is related to heart rate, which is triggered when the heart rhythm of the patient is too fast or too slow. In this work, the fusion of different physiological sensors is explored in order to create a robust heart rate estimation. A set of algorithms using heart rate variability index, Bayesian inference, neural networks, fuzzy logic and majority voting is proposed to fuse the information from the electrocardiogram, arterial blood pressure and photoplethysmogram. Three kinds of information are extracted from each source, namely, heart rate variability, the heart rate difference between sensors and the spectral analysis of low and high noise of each sensor. This information is used as input to the algorithms. Twenty recordings selected from the MIMIC database were used to validate the system. The results showed that neural networks fusion had the best false alarm reduction of 92.5 %, while the Bayesian technique had a reduction of 84.3 %, fuzzy logic 80.6 %, majority voter 72.5 % and the heart rate variability index 67.5 %. Therefore, the proposed algorithms showed good performance and could be useful in bedside monitors.

  5. Design of heart rate monitor based on piezoelectric sensor using an Arduino

    NASA Astrophysics Data System (ADS)

    Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.

    2017-01-01

    Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.

  6. A comparison of heart rate responses in racquet games.

    PubMed Central

    Docherty, D.

    1982-01-01

    The present study investigated the heart rate response to playing tennis with special reference to the skill levels and ages of the participants. Data obtained in a similar manner during earlier studies of badminton and squash players were compared with that obtained during tennis. The number of rallies, mean rally time and actual playing time in 30 minutes of play was also compared for the different skill levels and sports. Results showed that playing tennis raised the players' heart rates to 68-70% of their predicted maximum heart rate (PMHR). Playing squash and badminton could raise heart rates to 80-85% of the players' PMHR which was significantly higher than the values obtained for tennis. The actual skill level of the participants within their chosen sport did not have a significant effect in predicting the physical demands of squash or tennis but was important in predicting the heart rate response of badminton players. The more skillful the badminton player the greater the cardiac response as a result of game play. Analysis of time spent in actual play revealed that tennis players were involved in play for only five of the thirty minutes of game play, compared to 15 and 10 min respectively for squash and badminton. Skill level within each sport was only a significant factor in predicting length of play for squash players in which the medium and highly skilled groups played significantly longer than those of a lower level of skill. Images p96-a PMID:7104564

  7. Effect of suprachiasmatic lesions on diurnal heart rate rhythm in the rat

    NASA Technical Reports Server (NTRS)

    Saleh, M. A.; Winget, C. M.

    1977-01-01

    Heart rate and locomotor activity of rats kept under 12L/12D illumination regimen were recorded every six minutes for ten days using implantable radio transmitters. Some of the rats then received bilateral RF lesions into the suprachiasmatic nucleus (SCN). Control sham operations were performed on the rest of the animals. After recovery from surgery, recording of heart rate and locomotor activity was continued for ten days. SCN-lesioned rats showed no significant diurnal fluctuation in heart rate, while normal and sham-operated rats showed the normal diurnal rhythm in that function. The arrhythmic diurnal heart-rate pattern of SCN rats appeared to be correlated with their sporadic activity pattern. The integrity of the suprachiasmatic nucleus is therefore necessary for the generation and/or expression of diurnal rhythmicity in heart rate in the rat.

  8. Effects of volume loading and pressor agents in idiopathic orthostatic tachycardia

    NASA Technical Reports Server (NTRS)

    Jacob, G.; Shannon, J. R.; Black, B.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.

    1997-01-01

    BACKGROUND: Idiopathic orthostatic tachycardia (IOT) is characterized by an increase in heart rate (HR) with standing of > or = 30 bpm that is associated with elevated catecholamine levels and orthostatic symptoms. A dynamic orthostatic hypovolemia and alpha1-adrenoreceptor hypersensitivity have been demonstrated in IOT patients. There is evidence of an autonomic neuropathy affecting the lower-extremity blood vessels. METHODS AND RESULTS: We studied the effects of placebo, the alpha1-adrenoreceptor agonist midodrine (5 to 10 mg), the alpha2-adrenoreceptor agonist clonidine (0.1 mg), and I.V. saline (1 L) in 13 patients with IOT. Supine and upright blood pressure (BP) and HR were measured before and at 1 and 2 hours after intervention. Midodrine decreased both supine and upright HR (all HR values are given as bpm) at 2 hours (from 78+/-2 supine to 108+/-5 upright before treatment and from 69+/-2 supine to 95+/-5 upright after treatment, P<.005 for supine and P<.01 for upright). Saline decreased both supine and upright HR (from 80+/-3 supine to 112+/-5 upright before infusion and from 77+/-3 supine to 91+/-3 upright 1 hour after infusion, P<.005 for supine and P<.001 for upright). Clonidine decreased supine HR (from 78+/-2 to 74+/-2, P<.03) but did not affect the HR increase with standing. Clonidine very significantly decreased supine systolic BP (from 109+/-3 at baseline to 99+/-2 mm Hg at 2 hours, P<.001), and midodrine decreased supine systolic BP mildly. CONCLUSIONS: IOT responds best acutely to saline infusion to correct the underlying hypovolemia. Chronically, this can be accomplished with increased salt and water intake in conjunction with fludrocortisone. The response of patients to the alpha1-agonist midodrine supports the hypothesis of partial dysautonomia and indicates that the use of alpha1-agonists to pharmacologically replace lower-extremity postganglionic sympathetics is an appropriate overall goal of therapy. These findings are consistent with our

  9. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    PubMed

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  10. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability

    PubMed Central

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L.

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain. PMID:25324790

  11. Secondary ventricular fibrillation or pulseless ventricular tachycardia during cardiac arrest and epinephrine dosing.

    PubMed

    Straznitskas, Andrew D; Wong, Sylvia; Kupchik, Nicole; Carlbom, David

    2015-05-01

    Development of ventricular fibrillation or pulseless ventricular tachycardia after an initial rhythm of pulseless electrical activity or asystole is associated with significantly increased cardiac arrest mortality. To examine differences in epinephrine administration during cardiac arrest between patients who had a secondary ventricular fibrillation or ventricular tachycardia develop and patients who did not. Data were collected for 2 groups of patients with in-hospital cardiac arrest and an initial rhythm of pulseless electrical activity or asystole: those who had a secondary ventricular fibrillation or ventricular tachycardia develop (cases) and those who did not (controls). Dosing of epinephrine during cardiac arrest and other variables were compared between cases and controls. Of the 215 patients identified with an initial rhythm of pulseless electrical activity or asystole, 51 (23.7%) had a secondary ventricular fibrillation or ventricular tachycardia develop. Throughout the total duration of arrest, including periods of return of spontaneous circulation, the dosing interval for epinephrine in patients who had a secondary ventricular fibrillation or ventricular tachycardia develop was 1 mg every 3.4 minutes compared with 1 mg every 5 minutes in controls (P= .001). For the total duration of pulselessness, excluding periods of return of spontaneous circulation during the arrest, the dosing interval for epinephrine in patients who had a secondary ventricular fibrillation or ventricular tachycardia develop was 1 mg every 3.1 minutes versus 1 mg every 4.3 minutes in controls (P= .001). More frequent administration of epinephrine during cardiac arrest is associated with development of secondary ventricular fibrillation or ventricular tachycardia. ©2015 American Association of Critical-Care Nurses.

  12. An improved method of measuring heart rate using a webcam

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Ouyang, Jianfei; Yan, Yonggang

    2014-09-01

    Measuring heart rate traditionally requires special equipment and physical contact with the subject. Reliable non-contact and low-cost measurements are highly desirable for convenient and comfortable physiological self-assessment. Previous work has shown that consumer-grade cameras can provide useful signals for remote heart rate measurements. In this paper a simple and robust method of measuring the heart rate using low-cost webcam is proposed. Blood volume pulse is extracted by proper Region of Interest (ROI) and color channel selection from image sequences of human faces without complex computation. Heart rate is subsequently quantified by spectrum analysis. The method is successfully applied under natural lighting conditions. Results of experiments show that it takes less time, is much simpler, and has similar accuracy to the previously published and widely used method of Independent Component Analysis (ICA). Benefitting from non-contact, convenience, and low-costs, it provides great promise for popularization of home healthcare and can further be applied to biomedical research.

  13. A novel 'splice site' HCN4 Gene mutation, c.1737+1 G>T, causes familial bradycardia, reduced heart rate response, impaired chronotropic competence and increased short-term heart rate variability.

    PubMed

    Hategan, Lidia; Csányi, Beáta; Ördög, Balázs; Kákonyi, Kornél; Tringer, Annamária; Kiss, Orsolya; Orosz, Andrea; Sághy, László; Nagy, István; Hegedűs, Zoltán; Rudas, László; Széll, Márta; Varró, András; Forster, Tamás; Sepp, Róbert

    2017-08-15

    The most important molecular determinant of heart rate regulation in sino-atrial pacemaker cells includes hyperpolarization-activated, cyclic nucleotide-gated ion channels, the major isoform of which is encoded by the HCN4 gene. Mutations affecting the HCN4 gene are associated primarily with sick sinus syndrome. A novel c.1737+1 G>T 'splice-site' HCN4 mutation was identified in a large family with familial bradycardia which co-segregated with the disease providing a two-point LOD score of 4.87. Twelve out of the 22 investigated family members [4 males, 8 females average age 36 (SD 6) years] were considered as clinically affected (heart rate<60/min on resting ECG). Minimum [36 (SD 7) vs. 47 (SD 5) bpm, p=0.0087) and average heart rates [62 (SD 8) vs. 73 (SD 8) bpm, p=0.0168) were significantly lower in carriers on 24-hour Holter recordings. Under maximum exercise test carriers achieved significantly lower heart rates than non-carrier family members, and percent heart rate reserve and percent corrected heart rate reserve were significantly lower in carriers. Applying rigorous criteria for chronotropic incompetence a higher number of carriers exhibited chronotropic incompetence. Parameters, characterizing short-term variability of heart rate (i.e. rMSSD and pNN50%) were increased in carrier family members, even after normalization for heart rate, in the 24-hour ECG recordings with the same relative increase in 5-minute recordings. The identified novel 'splice site' HCN4 gene mutation, c.1737+1 G>T, causes familial bradycardia and leads to reduced heart rate response, impaired chronotropic competence and increased short-term heart rate variability in the mutation carriers. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    PubMed

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  15. Measuring task-related changes in heart rate variability.

    PubMed

    Moses, Ziev B; Luecken, Linda J; Eason, James C

    2007-01-01

    Small beat-to-beat differences in heart rate are the result of dynamic control of the cardiovascular system by the sympathetic and parasympathetic nervous systems. Heart rate variability (HRV) has been positively correlated with both mental and physical health. While many studies measure HRV under rest conditions, few have measured HRV during stressful situations. We describe an experimental protocol designed to measure baseline, task, and recovery values of HRV as a function of three different types of stressors. These stressors involve an attention task, a cold pressor test, and a videotaped speech presentation. We found a measurable change in heart rate in participants (n=10) during each task (all p's < 0.05). The relative increase or decrease from pre-task heart rate was predicted by task (one-way ANOVA, p= 0.0001). Spectral analysis of HRV during the attention task revealed consistently decreased measures of both high (68+/-7%, mean+/-S.E.) and low (62+/-13%) frequency HRV components as compared to baseline. HRV spectra for the cold pressor and speech tasks revealed no consistent patterns of increase or decrease from baseline measurements. We also found no correlation in reactivity measures between any of our tasks. These findings suggest that each of the tasks in our experimental design elicits a different type of stress response in an individual. Our experimental approach may prove useful to biobehavioral researchers searching for factors that determine individual differences in responses to stress in daily life.

  16. Interdisciplinary Team Huddles for Fetal Heart Rate Tracing Review.

    PubMed

    Thompson, Lisa; Krening, Cynthia; Parrett, Dolores

    2018-06-01

    To address an increase in unexpected poor outcomes in term neonates, our team developed a goal of high reliability and improved fetal safety in the culture of the Labor and Delivery nursing department. We implemented interdisciplinary reviews of fetal heart rate, along with a Category II fetal heart rate management algorithm and a fetal heart rate assessment rapid response alert to call for unscheduled reviews when needed. Enhanced communication between nurses and other clinicians supported an interdisciplinary approach to fetal safety, and we observed an improvement in health outcomes for term neonates. We share our experience with the intention of making our methods available to any labor and delivery unit team committed to safe, high-quality care and service excellence. Copyright © 2018 AWHONN. Published by Elsevier Inc. All rights reserved.

  17. Arrhythmogenic Right Ventricular Cardiomyopathy with Multiple Thrombi and Ventricular Tachycardia of Atypical Left Branch Bundle Block Morphology.

    PubMed

    Gong, Shenzhen; Wei, Xin; Liu, Guyue; Wu, Feng; Chen, Xiaoping

    2018-04-06

    A 61-year-old male patient was admitted to our hospital with recurrent palpitations and syncope. Electrocardiography, echocardiography, and contrast-enhanced computed tomography were performed. The patient was diagnosed with arrhythmogenic right ventricular cardiomyopathy (ARVC) complicated by multiple thrombi, and ventricular tachycardia (VT) without typical left bundle branch block (LBBB) morphology. This case suggests that VT is not always the sole contributor to syncope and death in patients with ARVC, and pulmonary embolism should be considered. Furthermore, VT with typical LBBB morphology is not an absolute necessity as a major criterion for the diagnosis of ARVC when the right heart is extremely enlarged.

  18. Human Fetal Heart Rate Dishabituation between Thirty and Thirty-Two Weeks Gestation.

    ERIC Educational Resources Information Center

    Sandman, Curt A.; Wadhwa, Pathik; Hetrick, William; Porto, Manuel; Peeke, Harmon V. S.

    1997-01-01

    Examined the ability of 32-week human fetuses to learn and recall information. Found a significant heart rate habituation pattern for a series of vibroacoustic stimuli. After a single novel stimulus, the heart rate to stimulus 1 reemerged. Uterine contractions were not related to presentation of the novel stimulus or change in heart rate after the…

  19. Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles

    PubMed Central

    Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard

    2011-01-01

    New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948

  20. Heart Rate Monitor for Portable MP3 Player.

    PubMed

    Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong

    2005-01-01

    This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

  1. Estimation of heart rate variability using a compact radiofrequency motion sensor.

    PubMed

    Sugita, Norihiro; Matsuoka, Narumi; Yoshizawa, Makoto; Abe, Makoto; Homma, Noriyasu; Otake, Hideharu; Kim, Junghyun; Ohtaki, Yukio

    2015-12-01

    Physiological indices that reflect autonomic nervous activity are considered useful for monitoring peoples' health on a daily basis. A number of such indices are derived from heart rate variability, which is obtained by a radiofrequency (RF) motion sensor without making physical contact with the user's body. However, the bulkiness of RF motion sensors used in previous studies makes them unsuitable for home use. In this study, a new method to measure heart rate variability using a compact RF motion sensor that is sufficiently small to fit in a user's shirt pocket is proposed. To extract a heart rate related component from the sensor signal, an algorithm that optimizes a digital filter based on the power spectral density of the signal is proposed. The signals of the RF motion sensor were measured for 29 subjects during the resting state and their heart rate variability was estimated from the measured signals using the proposed method and a conventional method. A correlation coefficient between true heart rate and heart rate estimated from the proposed method was 0.69. Further, the experimental results showed the viability of the RF sensor for monitoring autonomic nervous activity. However, some improvements such as controlling the direction of sensing were necessary for stable measurement. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Effect of varying heart rate on intra-ventricular filling fluid dynamics

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit

    2013-11-01

    Impaired exercise tolerance is used to delineate asymptomatic patients during the clinical diagnosis of diastolic left heart failure. Examining the effects of varying heart rate on intra-ventricular filling can provide a physical understanding of the specific flow characteristics that are impacted during exercise. In this study, diastolic filling was investigated with an anatomical left ventricle (LV) physical model under normal heart rate of 70 bpm, and varying exercise conditions of 100 bpm and 120 bpm. The LV model was incorporated into a flow loop and tuned for physiological inflow rates and outflow pressures. 2D PIV measurements were conducted along 3 parallel longitudinal planes. The systemic pressure was maintained the same across all test conditions. The E/A ratio was maintained within 1.0-1.2 across all heart rates. The strength of the mitral vortex ring formed during E-wave, as well as the peak incoming jet velocity, decreased with increasing heart rate. During peak flow of the A-wave, the vortex ring propagated farther into the LV for 120 bpm as compared to 70 bpm. The results point to the heightened role of the atrial kick for optimal LV filling during exercise conditions. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).

  3. Signal processing methodologies for an acoustic fetal heart rate monitor

    NASA Technical Reports Server (NTRS)

    Pretlow, Robert A., III; Stoughton, John W.

    1992-01-01

    Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.

  4. iHeartLift: a closed loop system with bio-feedback that uses music tempo variability to improve heart rate variability.

    PubMed

    Ho, Thomas C T; Chen, Xiang

    2011-01-01

    "Musica delenit bestiam feram" translates into "Music soothes the savage beast". There is a hidden truth in this ancient quip passed down from generations. Besides soothing the heart, it also incites the heart to a healthier level of heart rate variability (HRV). In this paper, an approach to use and test music and biofeedback to increase the heart rate variability for people facing daily stress is discussed. By determining the music tempo variability (MTV) of a piece of music and current heart rate variability, iHeartLift is able to compare the 2 trends and locate a musical piece that is suited to increase the user's heart rate variability to a healthier level. With biofeedback, the 2 trends are continuously compared in real-time and the musical piece is changed in accordance with the current comparisons. A study was conducted and it was generally found that HRV can be uplifted by music regardless of language and meaning of musical lyrics but with limitations to musical genre.

  5. Catecholamine-Independent Heart Rate Increases Require CaMKII

    PubMed Central

    Gao, Zhan; Singh, Madhu V; Hall, Duane D; Koval, Olha M.; Luczak, Elizabeth D.; Joiner, Mei-ling A.; Chen, Biyi; Wu, Yuejin; Chaudhary, Ashok K; Martins, James B; Hund, Thomas J; Mohler, Peter J; Song, Long-Sheng; Anderson, Mark E.

    2011-01-01

    Background Catecholamines increase heart rate by augmenting the cAMP responsive HCN4 ‘pacemaker current’ (If) and/or by promoting inward Na+/Ca2+ exchanger current (INCX), by a ‘Ca2+ clock’ mechanism in sinoatrial nodal cells (SANCs). The importance, identity and function of signals that connect If and Ca2+ clock mechanisms are uncertain and controversial, but the multifunctional Ca2+ and calmodulin-dependent protein kinase II (CaMKII) is required for physiological heart rate responses to β-adrenergic receptor (β-AR) stimulation. The aim of this stuy is to measure the contribution of the Ca2+ clock and CaMKII to cardiac pacing independent of β-AR agonist stimulation. Methods and Results We used the L-type Ca2+ channel agonist BayK 8644 (BayK) to activate the SANC Ca2+ clock. BayK and isoproterenol were similarly effective in increasing rates in SANCs and Langendorff-perfused hearts from WT control mice. In contrast, SANCs and isolated hearts from mice with CaMKII inhibition by transgenic expression of an inhibitory peptide (AC3-I) were resistant to rate increases by BayK. BayK only activated CaMKII in control SANCs, but increased ICa equally in all SANCs, indicating that increasing ICa was insufficient and suggesting CaMKII activation was required for heart rate increases by BayK. BayK did not increase If or protein kinase A (PKA)-dependent phosphorylation of phospholamban (at Ser16), indicating that increased SANC Ca2+ by BayK did not augment cAMP/PKA signaling at these targets. Late diastolic intracellular Ca2+ release and INCX were significantly reduced in AC3-I SANCs and the response to BayK was eliminated by ryanodine in all groups. Conclusions The Ca2+ clock is capable of supporting physiological fight or flight responses, independent of β-AR stimulation or If increases. Complete Ca2+ clock and β-AR stimulation responses require CaMKII. PMID:21406683

  6. Physiological thermoregulation in a crustacean? Heart rate hysteresis in the freshwater crayfish Cherax destructor.

    PubMed

    Goudkamp, Jacqueline E; Seebacher, Frank; Ahern, Mark; Franklin, Craig E

    2004-07-01

    Differential heart rates during heating and cooling (heart rate hysteresis) are an important thermoregulatory mechanism in ectothermic reptiles. We speculate that heart rate hysteresis has evolved alongside vascularisation, and to determine whether this phenomenon occurs in a lineage with vascularised circulatory systems that is phylogenetically distant from reptiles, we measured the response of heart rate to convective heat transfer in the Australian freshwater crayfish, Cherax destructor. Heart rate during convective heating (from 20 to 30 degrees C) was significantly faster than during cooling for any given body temperature. Heart rate declined rapidly immediately following the removal of the heat source, despite only negligible losses in body temperature. This heart rate 'hysteresis' is similar to the pattern reported in many reptiles and, by varying peripheral blood flow, it is presumed to confer thermoregulatory benefits particularly given the thermal sensitivity of many physiological rate functions in crustaceans.

  7. Using complexity metrics with R-R intervals and BPM heart rate measures.

    PubMed

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics-fractal (DFA) and recurrence (RQA) analyses-reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, "oversampled" BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics.

  8. Using complexity metrics with R-R intervals and BPM heart rate measures

    PubMed Central

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics—fractal (DFA) and recurrence (RQA) analyses—reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, “oversampled” BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics. PMID:23964244

  9. Heart Rate Recovery, Physical Activity Level, and Functional Status in Subjects With COPD.

    PubMed

    Morita, Andrea A; Silva, Laís K O; Bisca, Gianna W; Oliveira, Joice M; Hernandes, Nidia A; Pitta, Fabio; Furlanetto, Karina C

    2018-05-15

    A normal heart rate reflects the balance between the sympathetic and parasympathetic autonomic nervous system. When the difference between heart rate at the end of an exercise test and after 1 min of recovery, known as the 1-min heart rate recovery, is ≤ 12 beats/min, this may indicate an abnormal delay. We sought to compare physical activity patterns and subjects' functional status with COPD with or without delayed 1-min heart rate recovery after the 6-min walk test (6MWT). 145 subjects with COPD (78 men, median [interquartile range (IQR)] age 65 [60-73] y, body mass index 25 [21-30] kg/m 2 , FEV 1 45 ± 15% predicted) were underwent the following assessments: spirometry, 6MWT, functional status, and physical activity in daily life (PADL). A delayed heart rate recovery of 1 min was defined as ≤ 12 beats/min. Subjects with delayed 1-min heart rate recovery walked a shorter distance in the 6MWT compared to subjects without delayed heart rate recovery (median [IQR] 435 [390-507] m vs 477 [425-515] m, P = .01; 81 [71-87] vs 87 [79-98]% predicted, P = .002). Regarding PADL, subjects with delayed heart rate recovery spent less time in the standing position (mean ± SD 185 ± 89 min vs 250 ± 107 min, P = .002) and more time in sedentary positions (472 ± 110 min vs 394 ± 129 min, P = .002). Scores based on the self-care domain of the London Chest Activity of Daily Living questionnaire and the activity domain of the Pulmonary Functional Status and Dyspnea questionnaire were also worse in the group with delayed heart rate recovery (6 ± 2 points vs 5 ± 2 points; P = .039 and 29 ± 24 points vs 19 ± 17 points; P = .037, respectively). Individuals with COPD who exhibit delayed 1-min heart rate recovery after the 6MWT exhibited worse exercise capacity as well as a more pronounced sedentary lifestyle and worse functional status than those without delayed heart rate recovery. Despite its assessment simplicity, heart rate recovery after the 6MWT can be further explored

  10. Optically Remote Noncontact Heart Rates Sensing Technique

    NASA Astrophysics Data System (ADS)

    Thongkongoum, W.; Boonduang, S.; Limsuwan, P.

    2017-09-01

    Heart rate monitoring via optically remote noncontact technique was reported in this research. A green laser (5 mW, 532±10 nm) was projected onto the left carotid artery. The reflected laser light on the screen carried the deviation of the interference patterns. The interference patterns were recorded by the digital camera. The recorded videos of the interference patterns were frame by frame analysed by 2 standard digital image processing (DIP) techniques, block matching (BM) and optical flow (OF) techniques. The region of interest (ROI) pixels within the interference patterns were analysed for periodically changes of the interference patterns due to the heart pumping action. Both results of BM and OF techniques were compared with the reference medical heart rate monitoring device by which a contact measurement using pulse transit technique. The results obtained from BM technique was 74.67 bpm (beats per minute) and OF technique was 75.95 bpm. Those results when compared with the reference value of 75.43±1 bpm, the errors were found to be 1.01% and 0.69%, respectively.

  11. Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.

    PubMed

    Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D

    1998-08-01

    Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the

  12. [Autonomic contribution to the blood pressure and heart rate variability changes in early experimental hyperthyroidism].

    PubMed

    Safa-Tisseront, V; Ponchon, P; Blanc, J; Elghozi, J L

    1998-08-01

    A great deal of uncertainty persists regarding the exact nature of the interaction between autonomic nervous activity and thyroid hormones in the control of heart rate (HR) and blood pressure (BP). Thyrotoxicosis was produced by a daily intraperitoneal (i.p.) injection of L-thyroxine (0.5 mg/kg body wt in 1 ml of 5 mM NaOH for 5 days). Control rats received i.p. daily injections of the thyroxine solvant. Autonomic blockers were administered intravenously: atropine (0.5 mg/kg), atenolol (1 mg/kg), atenolol + atropine or prazosin (1 mg/kg). Eight animals were studied in each group. Thyroxine treatment was sufficient to induce a significant degree of tachycardia (423 +/- 6 vs 353 +/- 4 bpm; p < 0.001, unpaired Student's tests), systolic BP elevation (142 +/- 3 vs 127 +/- 2 mmHg; p < 0.001), pulse pressure increase (51 +/- 2 vs 41 +/- 2 mmHg, p < 0.01), cardiac hypertrophy (1.165 +/- 0.017 vs 1.006 +/- 0.012 g, p < 0.001), weight loss (-21 +/- 2 g; p < 0.001) and hyperthermia (37.8 +/- 0.1 vs 37.0 +/- 0.1 degrees C, p < 0.001). The intrinsic HR observed after double blockade (atenolol + atropine) was markedly increased after treatment with thyroxine (497 +/- 16 vs 373 +/- 10 bpm, p < 0.05). Vagal tone (difference between HR obtained after atenolol and intrinsic HR) was positively linearly related to intrinsic HR (r = 0.84; p < 0.01). Atenolol neither modified HR nor BP variability in rats with hyperthyrodism. The thyrotoxicosis was associated with a reduction of the 0.4 Hz component of BP variability (analyses on 102.4 sec segments, modulus 1.10 +/- 0.07 vs 1.41 +/- 0.06 mmHg; p < 0.01). Prazosin was without effect on this 0.4 Hz component in these animals. These data show a functional diminution of the vascular and cardiac sympathetic tone in experimental hyperthyroidism. Increased intrinsic HR resulting from the direct effect of thyroid hormone on the sinoatrial node is the main determinant of a tachycardia leading to a subsequent rise in cardiac output. The

  13. Spontaneous Transition of Double Tachycardias with Atrial Fusion in a Patient with Wolff-Parkinson-White Syndrome.

    PubMed

    Kim, Dongmin; Lee, Myung-Yong

    2016-07-01

    Among patients with Wolff-Parkinson-White syndrome, atrioventricular reciprocating tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) can coexist in a single patient. Direct transition of both tachycardias is rare; however, it can occur after premature atrial or ventricular activity if the cycle lengths of the two tachycardias are similar. Furthermore, persistent atrial activation by an accessory pathway (AP) located outside of the AV node during ongoing AVNRT is also rare. This article describes a case of uncommon atrial activation by an AP during AVNRT and gradual transition of the two supraventricular tachycardias without any preceding atrial or ventricular activity in a patient with preexcitation syndrome.

  14. Effects of Vibration and G-Loading on Heart Rate, Breathing Rate, and Response Time

    NASA Technical Reports Server (NTRS)

    Godinez, Angelica; Ayzenberg, Ruthie; Liston, Dorian B.; Stone, Leland S.

    2013-01-01

    Aerospace and applied environments commonly expose pilots and astronauts to G-loading and vibration, alone and in combination, with well-known sensorimotor (Cohen, 1970) and performance consequences (Adelstein et al., 2008). Physiological variables such as heart rate (HR) and breathing rate (BR) have been shown to increase with G-loading (Yajima et al., 1994) and vibration (e.g. Guignard, 1965, 1985) alone. To examine the effects of G-loading and vibration, alone and in combination, we measured heart rate and breathing rate under aerospace-relevant conditions (G-loads of 1 Gx and 3.8 Gx; vibration of 0.5 gx at 8, 12, and 16 Hz).

  15. A new method to measure heart rate with EMFi and PVDF materials.

    PubMed

    Kärki, S; Lekkala, J

    2009-01-01

    In this paper we propose a new simple method to measure the heart rate of a person sitting on a chair or lying in a bed. The heart rate is measured with a thin sensor pad consisting of separate electromechanical film (EMFi) and polyvinylidenefluoride (PVDF) transducers located beneath the leg of chair or bed. This study aims to evaluate the operation of the sensor system with measurements, and also to compare the results provided by the two transducer materials. Based on the results obtained here, the heart rates measured with the transducers mainly corresponded to the values of reference ECG signal. Some minor differences between the heart rate values of PVDF and EMFi appeared, especially in supine position, possible due to the material sensitivities to different force directions. However, to conclude, both materials seem to be convenient for this kind of measurement of heart rate.

  16. Heart rate detection from an electronic weighing scale.

    PubMed

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-08-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V(-1) N(-1) to 1670 nV V(-1) N(-1). The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland-Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was +/-21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate.

  17. Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.

    PubMed

    Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin

    2011-02-01

    Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.

  18. Resonance of about-weekly human heart rate rhythm with solar activity change.

    PubMed

    Cornelissen, G; Halberg, F; Wendt, H W; Bingham, C; Sothern, R B; Haus, E; Kleitman, E; Kleitman, N; Revilla, M A; Revilla, M; Breus, T K; Pimenov, K; Grigoriev, A E; Mitish, M D; Yatsyk, G V; Syutkina, E V

    1996-12-01

    In several human adults, certain solar activity rhythms may influence an about 7-day rhythm in heart rate. When no about-weekly feature was found in the rate of change in sunspot area, a measure of solar activity, the double amplitude of a circadian heart rate rhythm, approximated by the fit of a 7-day cosine curve, was lower, as was heart rate corresponds to about-weekly features in solar activity and/or relates to a sunspot cycle.

  19. Effect of Age and Other Factors on Maximal Heart Rate.

    ERIC Educational Resources Information Center

    Londeree, Ben R.; Moeschberger, Melvin L.

    1982-01-01

    To reduce confusion regarding reported effects of age on maximal exercise heart rate, a comprehensive review of the relevant English literature was conducted. Data on maximal heart rate after exercising with a bicycle, a treadmill, and after swimming were analyzed with regard to physical fitness and to age, sex, and racial differences. (Authors/PP)

  20. Effects of different training amplitudes on heart rate and heart rate variability in young rowers.

    PubMed

    Vaz, Marcelo S; Picanço, Luan M; Del Vecchio, Fabrício B

    2014-10-01

    The aim of this study was to investigate the autonomic nervous system recovery and the psychological response as a result of 3 training amplitudes on heart rate (HR), heart rate variability (HRV), and rate of perceived exertion (RPE) in rowing. Eight young rowers (16.8 ± 1.4 years) performed, in a randomized fashion, 2 sessions of high-intensity interval training, with high and low amplitude and a continuous training (CT) session, with the same exercise duration (10 minutes) and mean intensity (60% of maximal stroke test). The data of HR, HRV, and RPE were collected 5 minutes before, immediately after each session, and 24 hours later. High amplitude promoted higher impact in maximum HR (p ≤ 0.05) and RPE (p < 0.001) when compared with CT. For the time domain HRV variable, there was a statistically significant difference between moments of rest (pretraining or post 24 hours) and posttraining in all training sessions. Originally, we conclude that training with higher load variation between effort and recovery impacts HRV, HR, and RPE with greater intensity, but the younger rowers were ready for new training sessions 24 hours after either training method. Coaches can use the polarized training method, observing the stimulus nature and time required for recovery, because it may be an adequate strategy for the development of rower's conditioning.

  1. Variability in heart rate recovery measurements over 1 year in healthy, middle-aged adults.

    PubMed

    Mellis, M G; Ingle, L; Carroll, S

    2014-02-01

    This study assessed the longer-term (12-month) variability in post-exercise heart rate recovery following a submaximal exercise test. Longitudinal data was analysed for 97 healthy middle-aged adults (74 male, 23 female) from 2 occasions, 12 months apart. Participants were retrospectively selected if they had stable physical activity habits, submaximal treadmill fitness and anthropometric measurements between the 2 assessment visits. A submaximal Bruce treadmill test was performed to at least 85% age-predicted maximum heart rate. Absolute heart rate and Δ heart rate recovery (change from peak exercise heart rate) were recorded for 1 and 2 min post-exercise in an immediate supine position. Heart rate recovery at both time-points was shown to be reliable with intra-class correlation coefficient values ≥ 0.714. Absolute heart rate 1-min post-exercise showed the strongest agreement between repeat tests (r = 0.867, P < 0.001). Lower coefficient of variation (≤ 10.2%) and narrower limits of agreement were found for actual heart rate values rather than Δ heart rate recovery, and for 1-min rather than 2-min post-exercise recovery time points. Log-transformed values generated better variability with acceptable coefficient of variation for all measures (2.2-10%). Overall, 1 min post-exercise heart rate recovery data had least variability over the 12-month period in apparently healthy middle-aged adults. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Elevated resting heart rate is associated with dyslipidemia in middle-aged and elderly Chinese.

    PubMed

    Sun, Ji Chao; Huang, Xiao Lin; Deng, Xin Ru; Lv, Xiao Fei; Lu, Jie Li; Chen, Yu Hong; Bi, Yu Fang; Wang, Wei Qing; Xu, Min; Ning, Guang

    2014-08-01

    To study the relationship between resting heart rate and blood lipid level. A total of 9 415 subjects aged ⋝ 40 years were included in the present study. Their resting heart rate was monitored and their serum levels of triglyceride (TG), total cholesterol (TC), low density lipoprotein cholesterol (LDL-C) and high density lipoprotein cholesterol (HDL-C) were measured to define dyslipidemia according to the 2007 Chinese Guidelines on Prevention and Treatment of Dyslipidemia in Adults. The subjects were divided into group A with their resting heart rate <70 beats/min, group B with their resting heart rate =70-79 beats/min, group C with their resting heart rate =80-89 beats/min, and group D with their resting heart rate ⋝ 90 beats/min. High TG, TC, and LDL-C were presented across the resting heart rate (Ptrend <0.01). Multiple logistic regression analysis revealed that the risk of high TG and TC was higher in subjects with their resting heart rate ⋝ 90 beats/min than in those with their resting heart rate <70 beats/min (OR=1.42; 95% CI: 1.16-1.74 and OR=1.33; 95% CI: 1.09-1.64, respectively). Elevated resting heart rate is associated with high TG and TC in middle-aged and elderly Chinese subjects. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  3. Resting Heart Rate and Outcomes in Patients with Cardiovascular Disease: Where Do We Currently Stand?

    PubMed Central

    Menown, Ian BA; Davies, Simon; Gupta, Sandeep; Kalra, Paul R; Lang, Chim C; Morley, Chris; Padmanabhan, Sandosh

    2013-01-01

    Background Data from large epidemiological studies suggest that elevated heart rate is independently associated with cardiovascular and all-cause mortality in patients with hypertension and in those with established cardiovascular disease. Clinical trial findings also suggest that the favorable effects of beta-blockers and other heart rate–lowering agents in patients with acute myocardial infarction and congestive heart failure may be, at least in part, due to their heart rate–lowering effects. Contemporary clinical outcome prediction models such as the Global Registry of Acute Coronary Events (GRACE) score include admission heart rate as an independent risk factor. Aims This article critically reviews the key epidemiology concerning heart rate and cardiovascular risk, potential mechanisms through which an elevated resting heart rate may be disadvantageous and evaluates clinical trial outcomes associated with pharmacological reduction in resting heart rate. Conclusions Prospective randomised data from patients with significant coronary heart disease or heart failure suggest that intervention to reduce heart rate in those with a resting heart rate >70 bpm may reduce cardiovascular risk. Given the established observational data and randomised trial evidence, it now appears appropriate to include reduction of elevated resting heart rate by lifestyle +/− pharmacological therapy as part of a secondary prevention strategy in patients with cardiovascular disease. PMID:22954325

  4. The effect of competition on heart rate during kart driving: A field study.

    PubMed

    Matsumura, Kenta; Yamakoshi, Takehiro; Yamakoshi, Yasuhiro; Rolfe, Peter

    2011-09-09

    Both the act of competing, which can create a kind of mental stress, and participation in motor sports, which induces physical stress from intense g-forces, are known to increase heart rate dramatically. However, little is known about the specific effect of competition on heart rate during motor sports, particularly during four-wheel car driving. The goal of this preliminary study, therefore, was to investigate whether competition increases heart rate under such situations. The participants drove an entry-level formula kart during two competitive races and during solo driving against the clock while heart rate and g-forces were measured. Analyses showed that heart rate values during the races (168.8 beats/min) were significantly higher than those during solo driving (140.9 beats/min) and rest (75.1 beats/min). The results of this preliminary study indicate that competition heightens heart rate during four-wheel car driving. Kart drivers should be concerned about maintaining good health and developing physical strength.

  5. The effect of competition on heart rate during kart driving: A field study

    PubMed Central

    2011-01-01

    Background Both the act of competing, which can create a kind of mental stress, and participation in motor sports, which induces physical stress from intense g-forces, are known to increase heart rate dramatically. However, little is known about the specific effect of competition on heart rate during motor sports, particularly during four-wheel car driving. The goal of this preliminary study, therefore, was to investigate whether competition increases heart rate under such situations. Findings The participants drove an entry-level formula kart during two competitive races and during solo driving against the clock while heart rate and g-forces were measured. Analyses showed that heart rate values during the races (168.8 beats/min) were significantly higher than those during solo driving (140.9 beats/min) and rest (75.1 beats/min). Conclusions The results of this preliminary study indicate that competition heightens heart rate during four-wheel car driving. Kart drivers should be concerned about maintaining good health and developing physical strength. PMID:21906298

  6. Reduced heart rate response after premature ventricular contraction depending on severity of atrial fibrillation symptoms - Analysis on heart rate turbulence in atrial fibrillation patients.

    PubMed

    Makimoto, Hisaki; Blockhaus, Christian; Meyer, Christian; Lin, Tina; Jungen, Christiane; Eickholt, Christian; Clasen, Lukas; Schmidt, Jan; Kurt, Muhammed; Müller, Patrick; Shin, Dong-In; Kelm, Malte; Fürnkranz, Alexander

    2018-03-01

    The severity of symptoms during atrial fibrillation (AF) may be influenced by heart rate and blood pressure variation, due to irregular beats and the related adaptations in baroreflex sensitivity. This study investigated whether heart rate turbulence (HRT) as a reflection of baroreflex sensitivity is related to symptom severity during AF. Ninety-seven patients (pts) who underwent electrophysiological study were enrolled. Consecutive 56 pts had paroxysmal AF (21 with milder symptoms [EHRA I or II; Group-M], 35 with severe symptoms [EHRA III or IV; Group-S]), and 41 age-matched controls without AF were included. After delivering a single ventricular extrastimulus during sinus rhythm and repeating the process 10 times, the quantification of HRT was performed by measuring turbulence onset (TO: heart rate acceleration) and turbulence slope (TS: rate of heart rate deceleration). Group-M pts showed significantly diminished TO as compared to controls and Group-S pts (P = 0.012). There was no significant difference of the TS between the 3 groups. Given that a TO ≥ 0% or TS ≤ 2.5 ms/RR was considered abnormal, Group-M pts showed significantly higher incidences of abnormal HRT as compared to controls and Group-S pts (71% vs 40% vs 21%, respectively, P = 0.0012). Regression analysis demonstrated an independent and significant association between a diminished TO and milder AF symptoms (P < 0.05). The usual heart rate acceleration after premature ventricular contraction is significantly diminished in pts with milder AF symptoms as compared to pts with severe AF symptoms. The mechanism of association between this diminished response and symptoms should be further investigated.

  7. Heart rate measurement based on a time-lapse image.

    PubMed

    Takano, Chihiro; Ohta, Yuji

    2007-10-01

    Using a time-lapse image acquired from a CCD camera, we developed a non-contact and non-invasive device, which could measure both the respiratory and pulse rate simultaneously. The time-lapse image of a part of the subject's skin was consecutively captured, and the changes in the average image brightness of the region of interest (ROI) were measured for 30s. The brightness data were processed by a series of operations of interpolation as follows a first-order derivative, a low pass filter of 2 Hz, and a sixth-order auto-regressive (AR) spectral analysis. Fourteen sound and healthy female subjects (22-27 years of age) participated in the experiments. Each subject was told to keep a relaxed seating posture with no physical restriction. At the same time, heart rate was measured by a pulse oximeter and respiratory rate was measured by a thermistor placed at the external naris. Using AR spectral analysis, two clear peaks could be detected at approximately 0.3 and 1.2 Hz. The peaks were thought to correspond to the respiratory rate and the heart rate. Correlation coefficients of 0.90 and 0.93 were obtained for the measurement of heart rate and respiratory rate, respectively.

  8. Junctional tachycardia in a child with non-rheumatic fever streptococcal pharyngitis.

    PubMed

    Bansal, Neha; Karpawich, Peter P; Sriram, Chenni S

    2017-07-01

    Accelerated junctional rhythm has been reported in children in the setting of acute rheumatic fever; however, we describe a hitherto unreported case of isolated junctional tachycardia in a child with streptococcal pharyngitis, not meeting revised Jones criteria for rheumatic fever. A previously healthy, 9-year-old girl presented to the emergency department with complaints of sore throat, low-grade fever, and intermittent chest pain. She was found to have a positive rapid streptococcal antigen test. The initial electrocardiogram showed junctional tachycardia with atrioventricular dissociation in addition to prolonged and aberrant atrioventricular conduction. An echocardiogram revealed normal cardiac anatomy with normal biventricular function. The patient responded to treatment with amoxicillin for streptococcal pharyngitis. The junctional tachycardia and other electrocardiogram abnormalities resolved during follow-up.

  9. Heart rate sensitive optical coherence angiography

    NASA Astrophysics Data System (ADS)

    Alvarez, Karl; Lopez-Tremoleda, Jordi; Donnan, Rob; Michael-Titus, Adina T.; Tomlins, Peter H.

    2018-02-01

    Optical coherence angiography (OCA) enables visualisation of three-dimensional micro-vasculature from optical coherence tomography data volumes. Typically, various statistical methods are used to discriminate static tissue from blood flow within vessels. In this paper, we introduce a new method that relies upon the beating heart frequency to isolate blood vessels from the surrounding tissue. Vascular blood flow is assumed to be more strongly modulated by the heart-beat compared to surrounding tissue and therefore short-time Fourier transform of sequential measurements can discriminate the two. Furthermore, it is demonstrated that adjacent B-Scans within an OCT data volume can provide the required sampling frequency. As such, the technique can be considered to be a spatially mapped variation of photoplethysmography (PPG), whereby each image voxel operates as a PPG detector. This principle is demonstrated using both a model system and in vivo for monitoring the vascular changes effected by traumatic brain injury in mice. In vivo measurements were acquired at an A-Scan rate of 10kHz to form a 500x500x512 (lateral x lateral x axial) pixel volume, enabling sequential sampling of the mouse heart rate in an expected range of 300-600 bpm. One of the advantages of this new OCA processing method is that it can be used in conjunction with existing algorithms as an additional filter for signal to noise enhancement.

  10. Heart rate estimation from FBG sensors using cepstrum analysis and sensor fusion.

    PubMed

    Zhu, Yongwei; Fook, Victor Foo Siang; Jianzhong, Emily Hao; Maniyeri, Jayachandran; Guan, Cuntai; Zhang, Haihong; Jiliang, Eugene Phua; Biswas, Jit

    2014-01-01

    This paper presents a method of estimating heart rate from arrays of fiber Bragg grating (FBG) sensors embedded in a mat. A cepstral domain signal analysis technique is proposed to characterize Ballistocardiogram (BCG) signals. With this technique, the average heart beat intervals can be estimated by detecting the dominant peaks in the cepstrum, and the signals of multiple sensors can be fused together to obtain higher signal to noise ratio than each individual sensor. Experiments were conducted with 10 human subjects lying on 2 different postures on a bed. The estimated heart rate from BCG was compared with heart rate ground truth from ECG, and the mean error of estimation obtained is below 1 beat per minute (BPM). The results show that the proposed fusion method can achieve promising heart rate measurement accuracy and robustness against various sensor contact conditions.

  11. Short-term variability of blood pressure and heart rate in hyperthyroidism.

    PubMed

    Girard, A; Hugues, F C; Le Jeunne, C; Elghozi, J L

    1998-06-01

    The effect of hyperthyroidism on the short-term memory variability of blood pressure and heart rate was evaluated in 12 untreated hyperthyroid patients during thyrotoxicosis and after a 6 1/2 month treatment designed to achieve a stable euthyroid state. Beat-by-beat finger blood pressure was measured with a Finapres device. The pulse interval, from which pulse rate was derived, was obtained from the blood pressure signal. Due to the significant change in heart rhythm associated with thyrotoxicosis, both pulse interval (taken as a surrogate of heart period) and pulse rate (taken as a surrogate of heart rate) were computed. Power spectral analysis showed a reduction in the overall heart period variability in the supine position in the hyperthyroid compared to the euthyroid state. This effect was observed in the low-frequency (0.005-0.068 Hz), mid-frequency (0.068-0.127 Hz) and high-frequency (respiratory) domains as well, with a significant reduction of the modulus of these bands of 31%, 35% and 47%, respectively. The heart rate spectral modulus also exhibited a reduction of the high-frequency component (31%) in the supine position in the hyperthyroid subjects. These changes in heart rhythmicity corroborate a vagal deficit in hyperthyroidism. In addition, blood pressure spectral power exhibited a significant deficit in the orthostatism-induced mid-frequency systolic blood pressure rise in the hyperthyroid state (64%) compared with the euthyroid state. This observation may reflect a reduced vascular sympathetic activation with standing. The resulting vasodilatation could well contribute to normalize blood pressure in thyrotoxicosis in which cardiac output is increased.

  12. Deriving temperature and age appropriate heart rate centiles for children with acute infections.

    PubMed

    Thompson, M; Harnden, A; Perera, R; Mayon-White, R; Smith, L; McLeod, D; Mant, D

    2009-05-01

    To describe the reference range for heart rate in children aged 3 months-10 years presenting to primary care with self-limiting infections. Cross-sectional study of children presenting to primary care with suspected acute infection. Heart rate was measured using a pulse oximeter and axillary temperature using an electronic thermometer. Centile charts of heart rates expected at given temperatures for children with self-limiting infections were calculated. Ten general practice surgeries and two out-of-hours centres in England. 1933 children presenting with suspected acute infections were recruited from in-hours general practice surgeries (1050 or 54.3%) or out-of-hours centres (883 or 45.7%). After excluding children who subsequently attended hospital and those without a final diagnosis of acute infection, 1589 children were used to create the centile charts of whom (859 or 54.1%) had upper respiratory tract infections and (215 or 13.5%) non-specific viral illness. Median, 75th, 90th and 97th centiles of heart rate at each temperature level. Heart rate increased by 9.9-14.1 bpm with each 1 degrees C increment in temperature. The 50th, 75th, 90th and 97th centiles of heart rate at each temperature level are presented graphically. Age-specific centile charts of heart rates expected at different temperatures should be used by clinicians in the initial assessment of children with acute infections. The charts will identify children who have a heart rate higher than expected for a given temperature and facilitate the interpretation of changes in heart rate on reassessment. Further research on the predictive value of the centile charts is needed to optimise their diagnostic utility.

  13. Case report: an unstable wide QRS complexes tachycardia after ablation of a poster-septal accessory pathway: What is the mechanism?

    PubMed

    Wang, Huan; Che, Xiaoru

    2018-03-01

    Differentiation of wide QRS complex tachycardia required repeated electrophysiological stimuli and mapping. However, instability of tachycardia would increase the difficulty in differential diagnosis. In this paper, we reported a wide QRS tachycardia following ablation of an atrioventricular reentrant tachycardia participated by a poster-septal accessory pathway. Limited differentiation strategy was performed because the wide QRS tachycardia was self-limited and with unstable hemodynamics. We analyzed the mechanism of the wide QRS tachycardia by only 4 beats ventricular overpacing. On the basis of the last ventricular pacing, an atypical atrioventricular nodal reentrant tachycardia was confirmed. After slow-pathway modification, the wide QRS tachycardia was eliminated. It was an atypical atrial-ventricular node reentrant tachycardia with right bundle branch block. Reasonable analysis based on electrophysiological electrophysiologic knowledge was the basis of successful diagnosis and treatment.

  14. Universal structures of normal and pathological heart rate variability.

    PubMed

    Gañán-Calvo, Alfonso M; Fajardo-López, Juan

    2016-02-25

    The circulatory system of living organisms is an autonomous mechanical system softly tuned with the respiratory system, and both developed by evolution as a response to the complex oxygen demand patterns associated with motion. Circulatory health is rooted in adaptability, which entails an inherent variability. Here, we show that a generalized N-dimensional normalized graph representing heart rate variability reveals two universal arrhythmic patterns as specific signatures of health one reflects cardiac adaptability, and the other the cardiac-respiratory rate tuning. In addition, we identify at least three universal arrhythmic profiles whose presences raise in proportional detriment of the two healthy ones in pathological conditions (myocardial infarction; heart failure; and recovery from sudden death). The presence of the identified universal arrhythmic structures together with the position of the centre of mass of the heart rate variability graph provide a unique quantitative assessment of the health-pathology gradient.

  15. The effect of relaxing massage on heart rate and heart rate variability in purebred Arabian racehorses.

    PubMed

    Kowalik, Sylwester; Janczarek, Iwona; Kędzierski, Witold; Stachurska, Anna; Wilk, Izabela

    2017-04-01

    The objective of this study was to assess the effect of relaxing massage on the heart rate (HR) and heart rate variability (HRV) in young racehorses during their first racing season. In the study, 72 Purebred Arabian racehorses were included. The study was implemented during the full race season. The horses from control and experimental groups were included in regular race training 6 days a week. The horses from the experimental group were additionally subject to the relaxing massage 3 days a week during the whole study. HR and HRV were assumed as indicators of the emotional state of the horses. The measurements were taken six times, every 4-5 weeks. The HRV parameters were measured at rest, during grooming and saddling the horse and during warm-up walking under a rider. The changes of the parameters throughout the season suggest that the relaxing massage may be effectively used to make the racehorses more relaxed and calm. Moreover, the horses from the experimental group had better race performance records. © 2016 Japanese Society of Animal Science.

  16. Effect of Heart Rate on Arterial Stiffness as Assessed by Pulse Wave Velocity.

    PubMed

    Tan, Isabella; Butlin, Mark; Spronck, Bart; Xiao, Huanguang; Avolio, Alberto

    2017-07-24

    Vascular assessment is becoming increasingly important in the diagnosis of cardiovascular diseases. In particular, clinical assessment of arterial stiffness, as measured by pulse wave velocity (PWV), is gaining increased interest due to the recognition of PWV as an influential factor on the prognosis of hypertension as well as being an independent predictor of cardiovascular and all-cause mortality. Whilst age and blood pressure are established as the two major determinants of PWV, the influence of heart rate on PWV measurements remains controversial with conflicting results being observed in both acute and epidemiological studies. In a majority of studies investigating the acute effects of heart rate on PWV, results were confounded by concomitant changes in blood pressure. Observations from epidemiological studies have also failed to converge, with approximately just half of such studies reporting a significant blood-pressure-independent association between heart rate and PWV. Further to the lack of consensus on the effects of heart rate on PWV, the possible mechanisms contributing to observed PWV changes with heart rate have yet to be fully elucidated, although many investigators have attributed heart-rate related changes in arterial stiffness to the viscoelasticity of the arterial wall. With elevated heart rate being an independent prognostic factor of cardiovascular disease and its association with hypertension, the interaction between heart rate and PWV continues to be relevant in assessing cardiovascular risk. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. [Radioisotopic mapping of the arrhythmogenic focus in patients with chronic chagasic cardiomyopathy and sustained ventricular tachycardia].

    PubMed

    de Paola, A A; Balbão, C E; Castiglioni, M L; Barbieri, A; Mendonça, A; Netto, O S; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-06-01

    To localize the site of the origin of sustained ventricular tachycardia in chronic chagasic cardiomyopathy patients refractory to antiarrhythmic therapy by radionuclide angiography techniques. Five patients underwent radionuclide angiography by intravenous administration of 25mCi 99mTc. The images were obtained in sinus rhythm and during sustained ventricular tachycardia induced in the electrophysiologic laboratory for endocardial mapping. Amplitude and phase images were obtained resulting in a contraction wave synchronic to ventricular dispolarization. All patients had haemodynamic stability during the arrhythmia. One patient had incessant ventricular tachycardia. Mean ejection fraction was 0.38. In 4 patients the site of the origin of ventricular tachycardia was posterior and in one it was localized in the interventricular septum. There was identity in the site of the origin of ventricular tachycardia obtained by endocardial mapping or radionuclide angiography in all patients. The therapy was chemical ablation in 3 patients, surgical aneurysmectomy in one and pharmacologic therapy in the last patient. The site of the origin of ventricular tachycardia can be estimated by analyzing the contraction wave obtained by radionuclide angiography techniques in patients with hemodynamic stable sustained ventricular tachycardia.

  18. First experience with zero-fluoroscopic ablation for supraventricular tachycardias using a novel impedance and magnetic-field-based mapping system.

    PubMed

    Walsh, Katie A; Galvin, Joseph; Keaney, John; Keelan, Edward; Szeplaki, Gabor

    2018-02-23

    Zero- and near-zero-fluoroscopic ablation techniques reduce the harmful effects of ionizing radiation during invasive electrophysiology procedures. We aimed to test the feasibility and safety of a zero-fluoroscopic strategy using a novel integrated magnetic and impedance-based electroanatomical mapping system for radiofrequency ablation (RFA) of supraventricular tachycardias (SVTs). We retrospectively studied 92 consecutive patients undergoing electrophysiology studies with/without RFA for supraventricular tachycardia (SVT) performed by a single operator at a single center. The first 42 (Group 1) underwent a conventional fluoroscopic-guided approach and the second 50 (Group 2) underwent a zero-fluoroscopic approach using the Ensite Precision ™ 3-D magnetic and impedance-based mapping system (Abbott Inc). Group 1 comprised 14 AV-nodal re-entrant tachycardia (AVNRT), 12 typical atrial flutter, 4 accessory pathway (AP), 2 atrial tachycardia (AT), and 9 diagnostic EP studies (EPS). Group 2 comprised 16 AVNRT, 17 atrial flutter, 6 AP, 3 AT, 2 AV-nodal ablations, and 7 EPS. A complete zero-fluoroscopic approach was achieved in 94% of Group 2 patients. All procedures were acutely successful, and no complications occurred. There was a significant reduction in fluoroscopy dose, dose area product, and time (p < 0.0001, for all), with no difference in procedure times. Ablation time for typical atrial flutter was shorter in Group 2 (p = 0.006). A zero-fluoroscopic strategy for diagnosis and treatment of SVTs using this novel 3D-electroanatomical mapping system is feasible in majority of patients, is safe, reduces ionizing radiation exposure, and does not compromise procedural times, success rates, or complication rates.

  19. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    PubMed

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (P<0.001) but was higher in Chihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  20. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    PubMed

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  1. Cortisol and progestin release, heart rate and heart rate variability in the pregnant and postpartum mare, fetus and newborn foal.

    PubMed

    Nagel, C; Erber, R; Bergmaier, C; Wulf, M; Aurich, J; Möstl, E; Aurich, C

    2012-09-01

    The mechanisms leading to parturition in the horse in many aspects differ from those in other species. Pregnancy is maintained not by progesterone but by 5α-pregnanes and the progestin precursor pregnenolone originates from the fetus. As parturition approaches, the fetal adrenal switches from pregnenolone to cortisol synthesis but it is not known whether cortisol crosses the placenta. We hypothesized that in parallel to fetal cortisol release, cortisol in the maternal circulation increases before foaling and this increase can be determined in both saliva and plasma. In addition, maternal, fetal and neonatal heart rate and heart rate variability were measured. In 25 pregnant mares, saliva for cortisol analysis was collected 4 times daily from 15 days before to 5 days after foaling. In 13 mares, in addition, fetomaternal electrocardiogram (ECG) recordings were made and blood samples for progestin and cortisol analysis were collected once daily. Heart rate (HR) was recorded until 5 days after foaling. The heart rate variability (HRV) variables standard deviation of the beat-to-beat (RR) interval (SDRR) and root mean square of successive RR differences (RMSSD) were calculated. From Days 15 to 4 before parturition, progestin concentration increased (peak 267 ± 42 ng/mL) and decreased thereafter (P < 0.05, day of foaling 113 ± 18 ng/mL). A prepartum increase in maternal cortisol concentrations was evident in blood (P < 0.05) and saliva (P < 0.05) and paralleled the decrease in progestin concentrations. In mares, HR remained constant during the last days of pregnancy but decreased within one day after parturition (P < 0.05) while maternal HRV did not change. In the fetus and neonate, HR increased from before to after birth (P < 0.05) indicating increasing demands on the cardiovascular system with adaptation to extrauterine life. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Heart rate recovery and heart rate variability are unchanged in patients with coronary artery disease following 12 weeks of high-intensity interval and moderate-intensity endurance exercise training.

    PubMed

    Currie, Katharine D; Rosen, Lee M; Millar, Philip J; McKelvie, Robert S; MacDonald, Maureen J

    2013-06-01

    Decreased heart rate variability and attenuated heart rate recovery following exercise are associated with an increased risk of mortality in cardiac patients. This study investigated the effects of 12 weeks of moderate-intensity endurance exercise (END) and a novel low-volume high-intensity interval exercise protocol (HIT) on measures of heart rate recovery and heart rate variability in patients with coronary artery disease (CAD). Fourteen males with CAD participated in 12 weeks of END or HIT training, each consisting of 2 supervised exercise sessions per week. END consisted of 30-50 min of continuous cycling at 60% peak power output (PPO). HIT involved ten 1-min intervals at 88% PPO separated by 1-min intervals at 10% PPO. Heart rate recovery at 1 min and 2 min was measured before and after training (pre- and post-training, respectively) using a submaximal exercise bout. Resting time and spectral and nonlinear domain measures of heart rate variability were calculated. Following 12 weeks of END and HIT, there was no change in heart rate recovery at 1 min (END, 40 ± 12 beats·min(-1) vs. 37 ± 19 beats·min(-1); HIT, 31 ± 8 beats·min(-1) vs. 35 ± 8 beats·min(-1); p ≥ 0.05 for pre- vs. post-training) or 2 min (END, 44 ± 18 beats·min(-1) vs. 43 ± 19 beats·min(-1); HIT, 42 ± 10 beats·min(-1) vs. 50 ± 6 beats·min(-1); p ≥ 0.05 for pre- vs. post-training). All heart rate variability indices were unchanged following END and HIT training. In conclusion, neither END nor HIT exercise programs elicited training-induced improvements in cardiac autonomic function in patients with CAD. The absence of improvements with training may be attributed to the optimal medical management and normative pretraining state of our sample.

  3. QRS peak detection for heart rate monitoring on Android smartphone

    NASA Astrophysics Data System (ADS)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  4. An assessment of fatigue in patients with postural orthostatic tachycardia syndrome.

    PubMed

    Wise, Shelby; Ross, Amanda; Brown, Abigail; Evans, Meredyth; Jason, Leonard

    2017-05-01

    Individuals with postural orthostatic tachycardia syndrome share many symptoms with those who have chronic fatigue syndrome; one of which is severe fatigue. Previous literature found that those with chronic fatigue syndrome experience many forms of fatigue. The goal of this study was to investigate whether individuals with postural orthostatic tachycardia syndrome also experience multidimensional fatigue and whether these individuals can be clustered into subgroups based on the types of fatigue they endorse. A convenience sample of 138 participants (aged 14-29) with postural orthostatic tachycardia syndrome completed questionnaires that assessed fatigue, brain fog symptom severity, activities that improve brain fog, and brain fog-related disability. An exploratory factor analysis was conducted on the Fatigue Types Questionnaire, and a three-factor solution was produced. Factor scores were then used to cluster the patients into groups using a TwoStep cluster analysis. This resulted in two clusters, a high severity group and a low severity group. The clusters were then compared on a number of items related to symptom expression. Individuals within the more severe cluster had significantly more brain fog at the beginning and end of the survey when compared to cluster two. Those in the more severe cluster also described more activity impairment as well as more frequent, more severe, and more debilitation from postural orthostatic tachycardia syndrome and brain fog. The findings of the factor analysis suggest that patients with postural orthostatic tachycardia syndrome experience fatigue as a multidimensional construct and they also can be subgrouped based on symptom severity.

  5. Heart Rate Effects of Intraosseous Injections Using Slow and Fast Rates of Anesthetic Solution Deposition

    PubMed Central

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe. PMID:18327970

  6. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    PubMed

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  7. Smart pillow for heart-rate monitoring using a fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  8. Cognitive Performance and Heart Rate Variability: The Influence of Fitness Level

    PubMed Central

    Luque-Casado, Antonio; Zabala, Mikel; Morales, Esther; Mateo-March, Manuel; Sanabria, Daniel

    2013-01-01

    In the present study, we investigated the relation between cognitive performance and heart rate variability as a function of fitness level. We measured the effect of three cognitive tasks (the psychomotor vigilance task, a temporal orienting task, and a duration discrimination task) on the heart rate variability of two groups of participants: a high-fit group and a low-fit group. Two major novel findings emerged from this study. First, the lowest values of heart rate variability were found during performance of the duration discrimination task, compared to the other two tasks. Second, the results showed a decrement in heart rate variability as a function of the time on task, although only in the low-fit group. Moreover, the high-fit group showed overall faster reaction times than the low-fit group in the psychomotor vigilance task, while there were not significant differences in performance between the two groups of participants in the other two cognitive tasks. In sum, our results highlighted the influence of cognitive processing on heart rate variability. Importantly, both behavioral and physiological results suggested that the main benefit obtained as a result of fitness level appeared to be associated with processes involving sustained attention. PMID:23437276

  9. Evaluation of a novel high-resolution mapping technology for ablation of recurrent scar-related atrial tachycardias.

    PubMed

    Anter, Elad; McElderry, Thomas H; Contreras-Valdes, Fernando M; Li, Jianqing; Tung, Patricia; Leshem, Eran; Haffajee, Charles I; Nakagawa, Hiroshi; Josephson, Mark E

    2016-10-01

    Rhythmia is a new technology capable of rapid and high-resolution mapping. However, its potential advantage over existing technologies in mapping complex scar-related atrial tachycardias (ATs) has not yet been evaluated. The purpose of this study was to examine the utility of Rhythmia for mapping scar-related ATs in patients who had failed previous ablation procedure(s). This multicenter study included 20 patients with recurrent ATs within 2 years after a previous ablation procedure (1.8 ± 0.7 per patient). In all cases, the ATs could not be adequately mapped during the index procedure because of scar with fractionated electrograms, precluding accurate time annotation, frequent change in the tachycardia in response to pacing, and/or degeneration into atrial fibrillation. These patients underwent repeat mapping and ablation procedure with Rhythmia. From a total of 28 inducible ATs, 24 were successfully mapped. Eighteen ATs (75%) terminated during radiofrequency ablation and 4 (16.6%) with catheter pressure or entrainment from the site of origin or isthmus. Two ATs that were mapped to the interatrial septum slowed but did not terminate with ablation. In 21 of 24 ATs the mechanism was macroreentry, while in 3 of 24 the mechanism was focal. Interestingly, in 5 patients with previously failed ablation of an allegedly "focal" tachycardia, high-resolution mapping demonstrated macroreentrant arrhythmia. The mean mapping time was 28.6 ± 17 minutes, and the mean radiofrequency ablation time to arrhythmia termination was 3.2 ± 2.6 minutes. During a mean follow-up of 7.5 ± 3.1 months, 15 of 20 patients (75%) were free of AT recurrences. The Rhythmia mapping system may be advantageous for mapping complex scar-related ATs. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Effect of energy drink dose on exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise.

    PubMed

    An, Sang Min; Park, Jong Suk; Kim, Sang Ho

    2014-03-01

    The purpose of this research was to investigate the effects of exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise on caffeine concentration of energy drink. The volunteers for this study were 15 male university student. 15 subjects were taken basic physical examinations such as height, weight and BMI before the experiment. Primary tests were examined of VO2max per weight of each subjects by graded exercise test using Bruce protocol. Each of five subject was divided 3 groups (CON, ECGⅠ, ECGⅡ) by matched method based on weight and VO2max per weight what gained of primary test for minimize the differences of exercise capacity and ingestion of each groups. For the secondary tests, the groups of subjects were taken their materials before and after exercise as a blind test. After the ingestion, subjects were experimented on exercise test of VO2max 80% by treadmill until the all-out. Heart rate was measured by 1minute interval, and respiratory variables were analyzed VO2, VE, VT, RR and so on by automatic respiratory analyzer. And exercise exhaustion time was determined by stopwatch. Moreover, HRV was measured after exercise and recovery 3 min. Among the intake groups, ECGⅡ was showed the longest of exercise exhaustion time more than CON group (p = .05). Result of heart rate during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). Result of RPE during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). In conclusion, EDGⅡ showed the significant increase of exercise exhaustion time more than CON group (p=.05) and not significant differences in HR, RPE, RER, HRV, HRR, blood pressure (p > .05). Therefore, 2.5 mg/kg(-1) ingestion of energy drink might be positive effect

  11. Age-related disappearance of Mayer-like heart rate waves

    NASA Technical Reports Server (NTRS)

    Jarisch, W. R.; Ferguson, J. J.; Shannon, R. P.; Wei, J. Y.; Goldberger, A. L.

    1987-01-01

    The effect of age on the principal spectral components of heart rate obtained immediately after passive upright tilt was investigated in human subjects who underwent a 60-deg tilt over 9 sec. Two groups were examined, the first of which consisting of healthy male subjects aged 22-26 years, while the second was comprised of subjects aged 65-84 years on no medication; radiograms were recorded continuously beginning just prior to tilt until 3 min posttilt. The results of spectral analysis showed that elderly subjects did not exhibit the Mayer-like heart rate waves (the 0.07-0.09 Hz oscillations) that were present in the spectra of young subjects immediately after passive upright tilt. The findings are consistent with the concept of a 'dysautonomia of aging'. It is suggested that postural stress testing with spectral analysis of heart rate fluctuations may provide a useful way of assessing physiologic vs chronologic age.

  12. Estimating energy expenditure from heart rate in older adults: a case for calibration.

    PubMed

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  13. Gaussian Mixture Model of Heart Rate Variability

    PubMed Central

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  14. Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.

    PubMed

    See, Jason; Amora, Jonah L; Lee, Sheldon; Lim, Paul; Teo, Wee Siong; Tan, Boon Yew; Ho, Kah Leng; Lee, Chee Wan; Ching, Chi-Keong

    2016-07-01

    The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time. Copyright © Singapore Medical Association.

  15. Blockade of hyperpolarizing currents produces a dose-dependent effect on heart rate.

    PubMed

    Ziyatdinova, N I; Giniatullin, R A; Svyatova, N V; Zefirov, T L

    2001-03-01

    Intravenous injection of ZD 7288, a new specific hyperpolarizing current blocker, dose-dependently reduces heart rate in adult rats. The autonomic nervous system modulates changes in heart rate caused by hyperpolarizing currents.

  16. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders.

    PubMed

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu; Brundel, Bianca J J M; Peal, David S; Evans, David M; Nolte, Ilja M; Segrè, Ayellet V; Holm, Hilma; Handsaker, Robert E; Westra, Harm-Jan; Johnson, Toby; Isaacs, Aaron; Yang, Jian; Lundby, Alicia; Zhao, Jing Hua; Kim, Young Jin; Go, Min Jin; Almgren, Peter; Bochud, Murielle; Boucher, Gabrielle; Cornelis, Marilyn C; Gudbjartsson, Daniel; Hadley, David; van der Harst, Pim; Hayward, Caroline; den Heijer, Martin; Igl, Wilmar; Jackson, Anne U; Kutalik, Zoltán; Luan, Jian'an; Kemp, John P; Kristiansson, Kati; Ladenvall, Claes; Lorentzon, Mattias; Montasser, May E; Njajou, Omer T; O'Reilly, Paul F; Padmanabhan, Sandosh; St Pourcain, Beate; Rankinen, Tuomo; Salo, Perttu; Tanaka, Toshiko; Timpson, Nicholas J; Vitart, Veronique; Waite, Lindsay; Wheeler, William; Zhang, Weihua; Draisma, Harmen H M; Feitosa, Mary F; Kerr, Kathleen F; Lind, Penelope A; Mihailov, Evelin; Onland-Moret, N Charlotte; Song, Ci; Weedon, Michael N; Xie, Weijia; Yengo, Loic; Absher, Devin; Albert, Christine M; Alonso, Alvaro; Arking, Dan E; de Bakker, Paul I W; Balkau, Beverley; Barlassina, Cristina; Benaglio, Paola; Bis, Joshua C; Bouatia-Naji, Nabila; Brage, Søren; Chanock, Stephen J; Chines, Peter S; Chung, Mina; Darbar, Dawood; Dina, Christian; Dörr, Marcus; Elliott, Paul; Felix, Stephan B; Fischer, Krista; Fuchsberger, Christian; de Geus, Eco J C; Goyette, Philippe; Gudnason, Vilmundur; Harris, Tamara B; Hartikainen, Anna-Liisa; Havulinna, Aki S; Heckbert, Susan R; Hicks, Andrew A; Hofman, Albert; Holewijn, Suzanne; Hoogstra-Berends, Femke; Hottenga, Jouke-Jan; Jensen, Majken K; Johansson, Asa; Junttila, Juhani; Kääb, Stefan; Kanon, Bart; Ketkar, Shamika; Khaw, Kay-Tee; Knowles, Joshua W; Kooner, Angrad S; Kors, Jan A; Kumari, Meena; Milani, Lili; Laiho, Päivi; Lakatta, Edward G; Langenberg, Claudia; Leusink, Maarten; Liu, Yongmei; Luben, Robert N; Lunetta, Kathryn L; Lynch, Stacey N; Markus, Marcello R P; Marques-Vidal, Pedro; Mateo Leach, Irene; McArdle, Wendy L; McCarroll, Steven A; Medland, Sarah E; Miller, Kathryn A; Montgomery, Grant W; Morrison, Alanna C; Müller-Nurasyid, Martina; Navarro, Pau; Nelis, Mari; O'Connell, Jeffrey R; O'Donnell, Christopher J; Ong, Ken K; Newman, Anne B; Peters, Annette; Polasek, Ozren; Pouta, Anneli; Pramstaller, Peter P; Psaty, Bruce M; Rao, Dabeeru C; Ring, Susan M; Rossin, Elizabeth J; Rudan, Diana; Sanna, Serena; Scott, Robert A; Sehmi, Jaban S; Sharp, Stephen; Shin, Jordan T; Singleton, Andrew B; Smith, Albert V; Soranzo, Nicole; Spector, Tim D; Stewart, Chip; Stringham, Heather M; Tarasov, Kirill V; Uitterlinden, André G; Vandenput, Liesbeth; Hwang, Shih-Jen; Whitfield, John B; Wijmenga, Cisca; Wild, Sarah H; Willemsen, Gonneke; Wilson, James F; Witteman, Jacqueline C M; Wong, Andrew; Wong, Quenna; Jamshidi, Yalda; Zitting, Paavo; Boer, Jolanda M A; Boomsma, Dorret I; Borecki, Ingrid B; van Duijn, Cornelia M; Ekelund, Ulf; Forouhi, Nita G; Froguel, Philippe; Hingorani, Aroon; Ingelsson, Erik; Kivimaki, Mika; Kronmal, Richard A; Kuh, Diana; Lind, Lars; Martin, Nicholas G; Oostra, Ben A; Pedersen, Nancy L; Quertermous, Thomas; Rotter, Jerome I; van der Schouw, Yvonne T; Verschuren, W M Monique; Walker, Mark; Albanes, Demetrius; Arnar, David O; Assimes, Themistocles L; Bandinelli, Stefania; Boehnke, Michael; de Boer, Rudolf A; Bouchard, Claude; Caulfield, W L Mark; Chambers, John C; Curhan, Gary; Cusi, Daniele; Eriksson, Johan; Ferrucci, Luigi; van Gilst, Wiek H; Glorioso, Nicola; de Graaf, Jacqueline; Groop, Leif; Gyllensten, Ulf; Hsueh, Wen-Chi; Hu, Frank B; Huikuri, Heikki V; Hunter, David J; Iribarren, Carlos; Isomaa, Bo; Jarvelin, Marjo-Riitta; Jula, Antti; Kähönen, Mika; Kiemeney, Lambertus A; van der Klauw, Melanie M; Kooner, Jaspal S; Kraft, Peter; Iacoviello, Licia; Lehtimäki, Terho; Lokki, Marja-Liisa L; Mitchell, Braxton D; Navis, Gerjan; Nieminen, Markku S; Ohlsson, Claes; Poulter, Neil R; Qi, Lu; Raitakari, Olli T; Rimm, Eric B; Rioux, John D; Rizzi, Federica; Rudan, Igor; Salomaa, Veikko; Sever, Peter S; Shields, Denis C; Shuldiner, Alan R; Sinisalo, Juha; Stanton, Alice V; Stolk, Ronald P; Strachan, David P; Tardif, Jean-Claude; Thorsteinsdottir, Unnur; Tuomilehto, Jaako; van Veldhuisen, Dirk J; Virtamo, Jarmo; Viikari, Jorma; Vollenweider, Peter; Waeber, Gérard; Widen, Elisabeth; Cho, Yoon Shin; Olsen, Jesper V; Visscher, Peter M; Willer, Cristen; Franke, Lude; Erdmann, Jeanette; Thompson, John R; Pfeufer, Arne; Sotoodehnia, Nona; Newton-Cheh, Christopher; Ellinor, Patrick T; Stricker, Bruno H Ch; Metspalu, Andres; Perola, Markus; Beckmann, Jacques S; Smith, George Davey; Stefansson, Kari; Wareham, Nicholas J; Munroe, Patricia B; Sibon, Ody C M; Milan, David J; Snieder, Harold; Samani, Nilesh J; Loos, Ruth J F

    2013-06-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously established loci. Experimental downregulation of gene expression in Drosophila melanogaster and Danio rerio identified 20 genes at 11 loci that are relevant for heart rate regulation and highlight a role for genes involved in signal transmission, embryonic cardiac development and the pathophysiology of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate with risk of atrial fibrillation. Our findings provide fresh insights into the mechanisms regulating heart rate and identify new therapeutic targets.

  17. Heart rate and heart rate variability response to the transpiration of vortex-water by Begonia Eliator plants to the air in an office during visual display terminal work.

    PubMed

    Johansson, Benny

    2008-10-01

    This study explores the effects of vortex-water transpired from indoor greenery to office air, in relation to heart rate and heart rate variability during exposure to an electromagnetic field (EMF) from a visual display terminal (VDT). The study followed a randomized prospective single group cross-over design. Fifty (50) healthy volunteers, seated in any ordinary working posture in front of a VDT. Electrocardiography was measured in five 10-minute sequential tests. The VDT was turned off during the first test and switched on for the subsequent four tests. During tests 3 and 4, one of two Begonia Eliator plants, irrigated with either tap water or vortex-rotated (active) tap water during growth, was placed adjacent to the VDT. Heart rate, heart rate variability (HRV) and power spectral density (PSD) were analyzed. The heart rate was unchanged at the start of EMF exposure. The time domain measurements indicated a significant decrease in heart rate and a significant increase in HRV, accompanied by higher vagal tone in the presence, and finally in the absence, of the active plant. PSD parameters revealed significantly higher total power, as well as an increase in low frequencies (LF) and high frequencies (HF) in the condition induced by the active plant as well as after its removal. Very low frequencies (VLF) increased at EMF exposure whereas normally HF power decreased, accompanied by a rise in LF power and LF/HF ratio. HF power was higher at exposure to the active compared to the control plant. Spectral power density diagrams revealed an intensified spectral power band at frequencies of around 0.1 Hz at the condition of both plants, indicating systemic autonomic stability. The findings suggest that the parasympathetic response was associated with reduced heart rate, implicating restoration and maintenance of metabolic energy resources mediated by an involuntary adaptation to active plant-related stimuli.

  18. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    PubMed

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  19. Heart rate reactivity and current post-traumatic stress disorder when data are missing.

    PubMed

    Jeon-Slaughter, Haekyung; Tucker, Phebe; Pfefferbaum, Betty; North, Carol S; de Andrade, Bernardo Borba; Neas, Barbara

    2011-08-01

    This study demonstrates that auxiliary and exclusion criteria variables increase the effectiveness of missing imputation in correcting underestimation of physiologic reactivity in relation to post-traumatic stress disorder (PTSD) caused by deleting cases with missing physiologic data. This study used data from survivors of the 1995 Oklahoma City bombing and imputed missing heart rate data using auxiliary and exclusion criteria variables. Logistic regression was used to examine heart rate reactivity in relation to current PTSD. Of 113 survivors who participated in the bombing study's 7-year follow-up interview, 42 (37%) had missing data on heart rate reactivity due to exclusion criteria (medical illness or use of cardiovascular or psychotropic medications) or non-participation. Logistic regression results based on imputed heart rate data using exclusion criteria and auxiliary (the presence of any current PTSD arousal symptoms) variables showed that survivors with current bombing-related PTSD had significantly higher heart rates at baseline and recovered more slowly back to baseline heart rate during resting periods than survivors without current PTSD, while results based on complete cases failed to show significant correlations between current PTSD and heart rates at any assessment points. Suggested methods yielded an otherwise undetectable link between physiology and current PTSD. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  20. Heart rate variability of human in hypoxic oxygen-argon environment

    NASA Astrophysics Data System (ADS)

    Khayrullina, Rezeda; Smoleevskiy, Alexandr; Bubeev, Yuri

    Human adaptive capacity, reliability and stability in extreme environments depend primarily on the individual resistance to stresses, includes both innate and acquired components. We have conducted studies in six healthy subjects - men aged between 24 to 42 years who psychophysiological indicators acterizing the severity of stress reactions studied directly during an emergency situation, before and after it. The subjects were in a hypoxic oxygen-argon atmosphere 10 days. Cardiovascular system is one of the first to respond to stressful reaction. The method of heart rate variability (HRV) allows us to estimate balance of sympathetic and parasympathetic parts of vegetative nervous system. In the course of the baseline study it was found that resting heart rate (HR) in the examined individuals is within normal limits. During the experiment in all subjects there was a trend towards more frequent heartbeat. Each subject at one stage or another stay in a hypoxic oxygen-argon environment heart rate go beyond the group norm, but the extent and duration of these abnormalities were significantly different. Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). This suggests that the ability to adapt to living in the investigated gas environment have marked individual differences. SDNN (mean square deviation of all R-R intervals) is the integral indicator of the total effect of the sinus node to the sympathetic and parasympathetic parts of vegetative nervous system, as well as indicating the higher functional reserves of the cardiovascular systems. Increase in heart rate in the majority of subject was accompanied by an increase in individual SDNN. This suggests that the parasympathetic system is able to balance the increase in activity of the sympathetic system, and functional reserves are

  1. Low-dose β-blocker in combination with milrinone safely improves cardiac function and eliminates pulsus alternans in patients with acute decompensated heart failure.

    PubMed

    Kobayashi, Shigeki; Susa, Takehisa; Tanaka, Takeo; Murakami, Wakako; Fukuta, Seiko; Okuda, Shinichi; Doi, Masahiro; Wada, Yasuaki; Nao, Tomoko; Yamada, Jutaro; Okamura, Takayuki; Yano, Masafumi; Matsuzaki, Masunori

    2012-01-01

    The purpose of this study was to determine whether a low-dose β-blocker, in combination with milrinone, improves cardiac function in acute decompensated heart failure (ADHF) with tachycardia. Twenty ADHF patients (New York Heart Association classification III, n=1, and IV, n=19; heart rate [HR], 107±12 beats/min; left ventricular ejection fraction, 24±7%; cardiac index [CI], 2.2±0.6 L·min(-1)·m(-2); pulmonary capillary wedge pressure [PCWP], 26±8 mmHg) were enrolled in this study. The patients first underwent conventional therapy with milrinone, vasodilators and diuretics; landiolol (1.5-6.0 µg·kg(-1)·min(-1); i.v.), which is an ultra-short-acting β(1)-selective blocker, was then added to the treatment regimen to study its effect on hemodynamics. Low-dose landiolol (1.5 µg·kg(-1)·min(-1)) significantly reduced HR by 11% without changing blood pressure (BP) and CI, whereas higher doses (≥3.0 µg·kg(-1)·min(-1)) tended to decrease BP and CI while increasing PCWP and systemic vascular resistance. After treatment with landiolol (1.5 µg·kg(-1)·min(-1)), hemodynamic parameters such as PCWP, stroke volume index, SvO(2), rate pressure product, filling time/RR, E/e', and Tei index were significantly improved. A low-dose β-blocker in combination with milrinone improved cardiac function in ADHF patients with tachycardia; therefore, it may be considered as an adjunct therapy for use when standard therapy with milrinone is not effective at slowing HR.

  2. [The influence of individually fitted controlled breathing frequency on the heart rate variability indexes].

    PubMed

    Chuian, O M; Biriukova, O O; Ravaieva, M Iu

    2010-01-01

    We studied the changes in indexes of variability of heart rate and fractal neurodynamics under conditions of controlled breathing on fluctuation frequency of a spectrum of heart rate. It is shown that the controlled breathing, which frequency corresponds to a frequency of localization of the maximum peak of capacity ofa heart rate in low-frequency is a powerful mechanism of management of heart rate and change of a functional condition of an organism as a whole.

  3. Direct negative chronotropic action of desflurane on sinoatrial node pacemaker activity in the guinea pig heart.

    PubMed

    Kojima, Akiko; Ito, Yuki; Kitagawa, Hirotoshi; Matsuura, Hiroshi; Nosaka, Shuichi

    2014-06-01

    Desflurane inhalation is associated with sympathetic activation and concomitant increase in heart rate in humans and experimental animals. There is, however, little information concerning the direct effects of desflurane on electrical activity of sinoatrial node pacemaker cells that determines the intrinsic heart rate. Whole-cell patch-clamp experiments were conducted on guinea pig sinoatrial node pacemaker cells to record spontaneous action potentials and ionic currents contributing to sinoatrial node automaticity, namely, hyperpolarization-activated cation current (If), T-type and L-type Ca currents (ICa,T and ICa,L, respectively), Na/Ca exchange current (INCX), and rapidly and slowly activating delayed rectifier K currents (IKr and IKs, respectively). Electrocardiograms were recorded from ex vivo Langendorff-perfused hearts and in vivo hearts. Desflurane at 6 and 12% decreased spontaneous firing rate of sinoatrial node action potentials by 15.9% (n = 11) and 27.6% (n = 10), respectively, which was associated with 20.4% and 42.5% reductions in diastolic depolarization rate, respectively. Desflurane inhibited If, ICa,T, ICa,L, INCX, and IKs but had little effect on IKr. The negative chronotropic action of desflurane was reasonably well reproduced in sinoatrial node computer model. Desflurane reduced the heart rate in Langendorff-perfused hearts. High concentration (12%) of desflurane inhalation was associated with transient tachycardia, which was totally abolished by pretreatment with the β-adrenergic blocker propranolol. Desflurane has a direct negative chronotropic action on sinoatrial node pacemaking activity, which is mediated by its inhibitory action on multiple ionic currents. This direct inhibitory action of desflurane on sinoatrial node automaticity seems to be counteracted by sympathetic activation associated with desflurane inhalation in vivo.

  4. Gender- and age-related differences in heart rate dynamics: are women more complex than men?

    NASA Technical Reports Server (NTRS)

    Ryan, S. M.; Goldberger, A. L.; Pincus, S. M.; Mietus, J.; Lipsitz, L. A.

    1994-01-01

    OBJECTIVES. This study aimed to quantify the complex dynamics of beat-to-beat sinus rhythm heart rate fluctuations and to determine their differences as a function of gender and age. BACKGROUND. Recently, measures of heart rate variability and the nonlinear "complexity" of heart rate dynamics have been used as indicators of cardiovascular health. Because women have lower cardiovascular risk and greater longevity than men, we postulated that there are important gender-related differences in beat-to-beat heart rate dynamics. METHODS. We analyzed heart rate dynamics during 8-min segments of continuous electrocardiographic recording in healthy young (20 to 39 years old), middle-aged (40 to 64 years old) and elderly (65 to 90 years old) men (n = 40) and women (n = 27) while they performed spontaneous and metronomic (15 breaths/min) breathing. Relatively high (0.15 to 0.40 Hz) and low (0.01 to 0.15 Hz) frequency components of heart rate variability were computed using spectral analysis. The overall "complexity" of each heart rate time series was quantified by its approximate entropy, a measure of regularity derived from nonlinear dynamics ("chaos" theory). RESULTS. Mean heart rate did not differ between the age groups or genders. High frequency heart rate power and the high/low frequency power ratio decreased with age in both men and women (p < 0.05). The high/low frequency power ratio during spontaneous and metronomic breathing was greater in women than men (p < 0.05). Heart rate approximate entropy decreased with age and was higher in women than men (p < 0.05). CONCLUSIONS. High frequency heart rate spectral power (associated with parasympathetic activity) and the overall complexity of heart rate dynamics are higher in women than men. These complementary findings indicate the need to account for gender-as well as age-related differences in heart rate dynamics. Whether these gender differences are related to lower cardiovascular disease risk and greater longevity in

  5. A rare case of supraventricular tachycardia induced by Infliximab: a case report

    PubMed Central

    2009-01-01

    Background Infliximab, a chimeric monoclonal immunoglobulin antibody to tumor necrosis factor-α, has been established as a safe and effective treatment of rheumatoid arthritis, active and fistulising crohn's disease. Infliximab is generally well tolerated drug. The commonly reported cardiac side effects of Infliximab include exacerbation of congestive heart failure, hypotension and syncope. Symptomatic disorders of cardiac rhythm have been reported only rarely in few case reports and to the best of our knowledge, no tachyarrhythmia has been reported in past. Case report We report the case of a supraventricular tachycardia that occurred within three hours of Infliximab infusion in a patient with rheumatoid arthritis. Conclusion It is interesting to note that prior infusions in this patient did not precipitate similar consequences, thus, emphasising the importance of careful monitoring of patients on Infliximab therapy for possible reactions, even if prior exposures have been uneventful. PMID:19946518

  6. Computerized system for assessing heart rate variability.

    PubMed

    Frigy, A; Incze, A; Brânzaniuc, E; Cotoi, S

    1996-01-01

    The principal theoretical, methodological and clinical aspects of heart rate variability (HRV) analysis are reviewed. This method has been developed over the last 10 years as a useful noninvasive method of measuring the activity of the autonomic nervous system. The main components and the functioning of the computerized rhythm-analyzer system developed by our team are presented. The system is able to perform short-term (maximum 20 minutes) time domain HRV analysis and statistical analysis of the ventricular rate in any rhythm, particularly in atrial fibrillation. The performances of our system are demonstrated by using the graphics (RR histograms, delta RR histograms, RR scattergrams) and the statistical parameters resulted from the processing of three ECG recordings. These recordings are obtained from a normal subject, from a patient with advanced heart failure, and from a patient with atrial fibrillation.

  7. A PC-aided optical foetal heart rate detection system.

    PubMed

    Oweis, Rami J; As'ad, Hala; Aldarawsheh, Amany; Al-Khdeirat, Rawan; Lwissy, Kaldoun

    2014-01-01

    Safe monitoring of foetal heart rate is a valuable tool for the healthy evolution and wellbeing of both foetus and mother. This paper presents a non-invasive optical technique that allows for foetal heart rate detection using a photovoltaic infrared (IR) detector placed on the mother's abdomen. The system presented here consists of a photoplethysmography (PPG) circuit, abdomen circuit and a personal computer equipped with MATLAB. A near IR beam having a wavelength of 880 nm is transmitted through the mother's abdomen and foetal tissue. The received abdominal signal that conveys information pertaining to the mother and foetal heart rate is sensed by a low noise photodetector. The PC receives the signal through the National Instrumentation Data Acquisition Card (NIDAQ). After synchronous detection of the abdominal and finger PPG signals, the designed MATLAB-based software saves, analyses and extracts information related to the foetal heart rate. Extraction is carried out using recursive least squares adaptive filtration. Measurements on eight pregnant women with gestational periods ranging from 35-39 weeks were performed using the proposed system and CTG. Results show a correlation coefficient of 0.978 and a correlation confidence interval between 88-99.6%. The t test results in a p value of 0.034, which is less than 0.05. Low power, low cost, high signal-to-noise ratio, reduction of ambient light effect and ease of use are the main characteristics of the proposed system.

  8. Problem Behavior and Heart Rate Reactivity in Adopted Adolescents: Longitudinal and Concurrent Relations

    ERIC Educational Resources Information Center

    Bimmel, Nicole; van IJzendoorn, Marinus H.; Bakermans-Kranenburg, Marian J.; Juffer, Femmie; De Geus, Eco J. C.

    2008-01-01

    The present longitudinal study examined resting heart rate and heart rate variability and reactivity to a stressful gambling task in adopted adolescents with aggressive, delinquent, or internalizing behavior problems and adopted adolescents without behavior problems (total N=151). Early-onset delinquent adolescents showed heart rate…

  9. All-cancers mortality rates approaching diseases of the heart mortality rates as leading cause of death in Texas.

    PubMed

    Wyatt, Stephen W; Maynard, William Ryan; Risser, David R; Hakenewerth, Anne M; Williams, Melanie A; Garcia, Rebecca

    2014-01-01

    Diseases of the heart and malignant neoplasms (all-cancers) are the leading causes of death in the United States. The gap between the two has been closing in recent years. To assess the gap status in Texas and to establish a baseline to support evaluation efforts for the Cancer Prevention Research Institute of Texas, mortality data from 2006 to 2009 were analyzed. Immediate cause of death data in Texas for the years 2006-2009 were analyzed and rates developed by sex, race/ethnicity, and four metropolitan counties. Overall, for the years 2006-2009, the age-adjusted mortality rates (AARs) among Texas residents for both diseases of the heart and all-cancers decreased; however, during this time frame, there was greater improvement in diseases of the heart AARs as compared with all-cancers AARs. For the four large metropolitan counties of Bexar, Dallas, Harris, and Travis, data were analyzed by sex and race/ethnicity, and 11 of the 12 largest percent mortality rate decreases were for diseases of the heart. Age-adjusted mortality rates among Texas residents from diseases of the heart are showing improvement as compared with the rates for all-cancers.

  10. Cardiovascular Fitness and Maximal Heart Rate Differences Among Three Ethnic Groups.

    ERIC Educational Resources Information Center

    Farrell, S. W.

    1988-01-01

    Examination of differences in maximal heart rate and treadmill time among three ethnic groups revealed no significant age-adjusted differences among white, black, and Mexican-American males, and suggested that black females' lower maximal heart rate may be explained by their lower cardiovascular fitness level when compared to those of other…

  11. Relative refractoriness of left ventricular contraction underlies human tachycardia-induced mechanical and electrical alternans.

    PubMed

    Kashimura, Takeshi; Kodama, Makoto; Watanabe, Tohru; Tanaka, Komei; Hayashi, Yuka; Ohno, Yukako; Obata, Hiroaki; Ito, Masahiro; Hirono, Satoru; Hanawa, Haruo; Minamino, Tohru

    2014-02-01

    Mechanical alternans (MA) and electrical alternans (EA) are predictors of cardiac events. Experimental studies have suggested that refractoriness of calcium cycling underlies these cardiac alternans. However, refractoriness of left ventricular contraction has not been examined in patients with cardiac alternans. In 51 patients with miscellaneous heart diseases, incremental right atrial pacing was performed to induce MA and EA. MA was quantified by alternans amplitude (AA: the difference between left ventricular dP/dt of a strong beat and that of a weak beat), and AA at 100/min (AA100) and maximal AA (AAmax) were measured. EA was defined as alternation of T wave morphology in 12-lead electrocardiogram. Relative refractoriness of left ventricular contraction was examined by drawing the mechanical restitution curve under a basal coupling interval (BCL) of 600 ms (100/min) and was assessed by the slope at BCL (Δmechanical restitution). Postextrasystolic potentiation (PESP) was also examined and the slope of PESP curve (ΔPESP) was assessed as a property to alternate strong and weak beats. MA and EA were induced in 19 patients and in none at 100/min or less, and at any heart rate in 32 and in 10, respectively. AA100 and AAmax correlated positively with Δmechanical restitution and negatively with ΔPESP. Patients with EA had a significantly larger Δmechanical restitution and a significantly larger absolute value of ΔPESP than those without. In patients with MA and EA, the left ventricular contractile force during tachycardia is under relative refractoriness and prone to cause large fluctuation of contractile force. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  12. Association of educational status with heart rate recovery: a population-based propensity analysis.

    PubMed

    Shishehbor, Mehdi H; Baker, David W; Blackstone, Eugene H; Lauer, Michael S

    2002-12-01

    An abnormally attenuated heart rate recovery after exercise is a predictor of mortality that is thought to reflect decreased parasympathetic activity. Lower educational level may be associated with automatic imbalance. We sought to assess the association of educational level with heart rate recovery. Among 5246 healthy adults from a population-based cohort who underwent exercise testing, 874 (17%) did not graduate from high school, 1823 (35%) completed high school, and 2549 (49%) attended at least some college. An abnormal heart rate recovery was defined as a difference of heart rate and that after 2 minutes of recovery. Propensity scores were used to account for differences by educational status. An abnormal heart rate recovery was more common among adults who did not graduate from high school compared with those who attended at least some college (50% [440/874] vs. 28% [701/2549]; odds ratio [OR]: 2.7; 95% confidence interval [CI]: 2.3 to 3.1; P <0.001). After using propensity scores, lower educational status remained associated with an abnormal heart rate recovery (OR = 1.9; 95% CI: 1.6 to 2.4; P <0.001). During 12-years of follow-up, there were 327 deaths. Poor educational status was associated with greater mortality (9% [80/874] vs. 6% [247/4372]; unadjusted hazard ratio [HR] = 1.9; 95% CI: 1.4 to 2.5; P <0.001). However, after accounting for age, sex, and heart rate recovery, educational status was a weaker predictor (HR = 1.3; 95% CI: 1.0 to 1.7). Educational status is independently associated with an abnormal heart rate recovery.

  13. Reliability of the Parabola Approximation Method in Heart Rate Variability Analysis Using Low-Sampling-Rate Photoplethysmography.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol

    2017-10-24

    Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.

  14. Heart rate variability as determinism with jump stochastic parameters.

    PubMed

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  15. Music structure determines heart rate variability of singers

    PubMed Central

    Vickhoff, Björn; Malmgren, Helge; Åström, Rickard; Nyberg, Gunnar; Ekström, Seth-Reino; Engwall, Mathias; Snygg, Johan; Nilsson, Michael; Jörnsten, Rebecka

    2013-01-01

    Choir singing is known to promote wellbeing. One reason for this may be that singing demands a slower than normal respiration, which may in turn affect heart activity. Coupling of heart rate variability (HRV) to respiration is called Respiratory sinus arrhythmia (RSA). This coupling has a subjective as well as a biologically soothing effect, and it is beneficial for cardiovascular function. RSA is seen to be more marked during slow-paced breathing and at lower respiration rates (0.1 Hz and below). In this study, we investigate how singing, which is a form of guided breathing, affects HRV and RSA. The study comprises a group of healthy 18 year olds of mixed gender. The subjects are asked to; (1) hum a single tone and breathe whenever they need to; (2) sing a hymn with free, unguided breathing; and (3) sing a slow mantra and breathe solely between phrases. Heart rate (HR) is measured continuously during the study. The study design makes it possible to compare above three levels of song structure. In a separate case study, we examine five individuals performing singing tasks (1–3). We collect data with more advanced equipment, simultaneously recording HR, respiration, skin conductance and finger temperature. We show how song structure, respiration and HR are connected. Unison singing of regular song structures makes the hearts of the singers accelerate and decelerate simultaneously. Implications concerning the effect on wellbeing and health are discussed as well as the question how this inner entrainment may affect perception and behavior. PMID:23847555

  16. Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.

    PubMed Central

    Iyriboz, Y; Powers, S; Morrow, J; Ayers, D; Landry, G

    1991-01-01

    Pulse oximeters are being widely used for non-invasive, simultaneous assessment of haemoglobin oxygen saturation. They are reliable, accurate, relatively inexpensive and portable. Pulse oximeters are often used for estimating heart rate at rest and during exercise. However, at present the data available to validate their use as heart rate monitors are not sufficient. We evaluated the accuracy of two oximeters (Radiometer, ear and finger probe; Ohmeda 3700, ear probe) in monitoring heart rate during incremental exercise by comparing the pulse oximeters with simultaneous ECG readings. Data were collected on eight men (713 heart rate readings) during graded cycle ergometer and treadmill exercise to volitional fatigue. Analysis by linear regression revealed that general oximeter readings significantly correlated with those of ECG (r = 0.91, P less than 0.0001). However, comparison of heart rate at each level of work showed that oximeter readings significantly (P less than 0.05) under-estimated rates above 155 beats/min. These results indicate that the use of pulse oximeters as heart rate monitors during strenuous exercise is questionable. This inaccuracy may well originate from the instability of the probes, sweating, other artefacts during exercise, and measurement of different components in the cardiovascular cycle. PMID:1777787

  17. Heart rate and outcome in heart failure with reduced ejection fraction: Differences between atrial fibrillation and sinus rhythm-A CIBIS II analysis.

    PubMed

    Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel

    2017-09-01

    Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.

  18. Pharmacological heart rate lowering in patients with a preserved ejection fraction-review of a failing concept.

    PubMed

    Meyer, Markus; Rambod, Mehdi; LeWinter, Martin

    2018-07-01

    Epidemiological studies have demonstrated that high resting heart rates are associated with increased mortality. Clinical studies in patients with heart failure and reduced ejection fraction have shown that heart rate lowering with beta-blockers and ivabradine improves survival. It is therefore often assumed that heart rate lowering is beneficial in other patients as well. Here, we critically appraise the effects of pharmacological heart rate lowering in patients with both normal and reduced ejection fraction with an emphasis on the effects of pharmacological heart rate lowering in hypertension and heart failure. Emerging evidence from recent clinical trials and meta-analyses suggest that pharmacological heart rate lowering is not beneficial in patients with a normal or preserved ejection fraction. This has just begun to be reflected in some but not all guideline recommendations. The detrimental effects of pharmacological heart rate lowering are due to an increase in central blood pressures, higher left ventricular systolic and diastolic pressures, and increased ventricular wall stress. Therefore, we propose that heart rate lowering per se reproduces the hemodynamic effects of diastolic dysfunction and imposes an increased arterial load on the left ventricle, which combine to increase the risk of heart failure and atrial fibrillation. Pharmacologic heart rate lowering is clearly beneficial in patients with a dilated cardiomyopathy but not in patients with normal chamber dimensions and normal systolic function. These conflicting effects can be explained based on a model that considers the hemodynamic and ventricular structural effects of heart rate changes.

  19. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

    PubMed

    Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh

    2017-11-01

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.

  20. Impaired heart rate variability and altered cardiac sympathovagal balance after antidepressant overdose.

    PubMed

    Waring, W S; Rhee, J Y; Bateman, D N; Leggett, G E; Jamie, H

    2008-11-01

    Antidepressant overdose may be associated with significant cardiotoxicity, and recent data have shown that acute toxic effects are associated with impaired heart rate variability. This study was designed to examine the feasibility of non-invasive heart rate variability recording in patients that present to hospital after deliberate antidepressant ingestion. This was a prospective study of 72 consecutive patients attending the Emergency Department after deliberate antidepressant overdose and 72 age-matched patients that ingested paracetamol, as a control group. Single time-point continuous electrocardiographic recordings were used to allow spectral analyses of heart rate variability determined in low-frequency (LF) and high-frequency (HF) domains. The LF:HF ratio was used to represent overall sympathovagal cardiac activity. Antidepressant overdose was associated with reduced overall heart rate variability: 1329 vs. 2018 ms(2) (P = 0.0239 by Mann-Whitney test). Variability in the LF domain was higher (64.8 vs. 49.8, P = 0.0006), whereas that in the HF domain was lower (24.3 vs. 36.4, P = 0.0001), and the LF:HF ratio was higher in the antidepressant group (2.4 vs. 1.2, P = 0.0003). Antidepressant overdose is associated with impaired heart rate variability in a pattern consistent with excess cardiac sympathetic activity. Further work is required to establish the significance of these findings and to explore whether the impairment of heart rate variability may be used to predict the development of arrhythmia in this patient group.

  1. The Relationship Between Heart Rate Reserve and Oxygen Uptake Reserve in Heart Failure Patients on Optimized and Non-Optimized Beta-Blocker Therapy

    PubMed Central

    Carvalho, Vitor Oliveira; Guimarães, Guilherme Veiga; Bocchi, Edimar Alcides

    2008-01-01

    BACKGROUND The relationship between the percentage of oxygen consumption reserve and percentage of heart rate reserve in heart failure patients either on non-optimized or off beta-blocker therapy is known to be unreliable. The aim of this study was to evaluate the relationship between the percentage of oxygen consumption reserve and percentage of heart rate reserve in heart failure patients receiving optimized and non-optimized beta-blocker treatment during a treadmill cardiopulmonary exercise test. METHODS A total of 27 sedentary heart failure patients (86% male, 50±12 years) on optimized beta-blocker therapy with a left ventricle ejection fraction of 33±8% and 35 sedentary non-optimized heart failure patients (75% male, 47±10 years) with a left ventricle ejection fraction of 30±10% underwent the treadmill cardiopulmonary exercise test (Naughton protocol). Resting and peak effort values of both the percentage of oxygen consumption reserve and percentage of heart rate reserve were, by definition, 0 and 100, respectively. RESULTS The heart rate slope for the non-optimized group was derived from the points 0.949±0.088 (0 intercept) and 1.055±0.128 (1 intercept), p<0.0001. The heart rate slope for the optimized group was derived from the points 1.026±0.108 (0 intercept) and 1.012±0.108 (1 intercept), p=0.47. Regression linear plots for the heart rate slope for each patient in the non-optimized and optimized groups revealed a slope of 0.986 (almost perfect) for the optimized group, but the regression analysis for the non-optimized group was 0.030 (far from perfect, which occurs at 1). CONCLUSION The relationship between the percentage of oxygen consumption reserve and percentage of heart rate reserve in patients on optimized beta-blocker therapy was reliable, but this relationship was unreliable in non-optimized heart failure patients. PMID:19060991

  2. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    PubMed

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  3. Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    PubMed Central

    Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592

  4. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    PubMed

    Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  5. Bundle-branch reentry ventricular tachycardia after transcatheter aortic valve replacement

    PubMed Central

    de la Rosa Riestra, Adriana; Rubio Caballero, José Amador; Freites Estévez, Alfonso; Alonso Belló, Javier; Botas Rodríguez, Javier

    2016-01-01

    An 83-year-old male suffering from severe symptomatic aortic valve stenosis received an implant of a biological aortic prosthesis through the femoral artery without complications. Seven days after dischargement he experienced a syncope. The patient was wearing an ECG holter monitor that day, which showed a wide QRS complex tachycardia of 300 beats per minute. The electrophysiological study revealed a bundle-branch reentry ventricular tachycardia as the cause of the syncope. Radio-frequency was applied on the right-bundle branch. Twelve months later, the patient has remained asymptomatic. PMID:27134443

  6. Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.

    PubMed

    Sell, Katie M; Ledesma, Allison B

    2016-08-01

    Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.

  7. Optimal Body Temperature in Transitional ELBW Infants Using Heart Rate and Temperature as Indicators

    PubMed Central

    Knobel, Robin B.; Holditch-Davis, Diane; Schwartz, Todd A.

    2013-01-01

    Extremely low birth weight (ELBW) infants are vulnerable to cold stress after birth. Therefore, caregivers need to control body temperature optimally to minimize energy expenditure. Objective We explored body temperature in relationship to heart rate in ELBW infants during their first 12 hours to help identify the ideal set point for incubator control of body temperature. Design Within subject, multiple-case design. Setting A tertiary NICU in North Carolina. Participants 10 infants, born less than 29 weeks gestation and weighing 400-1000 grams. Methods Heart rate and abdominal body temperature were measured at 1-minute intervals for 12 hours. Heart rates were considered normal if they were between the 25th and 75th percentile for each infant. Results Abdominal temperatures were low throughout the 12-hour study period (mean 35.17° C-36.68° C). Seven of ten infants had significant correlations between abdominal temperature and heart rate. Heart rates above the 75th percentile were associated with low and high abdominal temperatures; heart rates less than the 25th percentile were associated with very low abdominal temperatures. The extent to which abdominal temperature was abnormally low was related the extent to which the heart rate trended away from normal in six of the ten infants. Optimal temperature control point that maximized normal heart rate observations for each infant was between 36.8° C and 37° C. Conclusions Hypothermia was associated with abnormal heart rates in transitional ELBW infants. We suggest nurses set incubator servo between 36.8° C and 36.9° C to optimally control body temperature for ELBW infants. PMID:20409098

  8. Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    NASA Technical Reports Server (NTRS)

    Buxton, Roxanne E.; West, Michael R.; Kalogera, Kent L.; Hanson, Andrea M.

    2016-01-01

    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an

  9. [Detection of Heart Rate of Fetal ECG Based on STFT and BSS].

    PubMed

    Wang, Xu; Cai, Kun

    2016-01-01

    Changes in heart rate of fetal is function regulating performance of the circulatory system and the central nervous system, it is significant to detect heart rate of fetus in perinatal fetal. This paper puts forward the fetal heart rate detection method based on short time Fourier transform and blind source separation. First of all, the mixed ECG signal was preprocessed, and then the wavelet transform technique was used to separate the fetal ECG signal with noise from mixed ECG signal, after that, the short-time Fourier transform and the blind separation were carried on it, and then calculated the correlation coefficient of it, Finally, An independent component that it has strongest correlation with the original signal was selected to make FECG peak detection and calculated the fetal instantaneous heart rate. The experimental results show that the method can improve the detection rate of the FECG peak (R), and it has high accuracy in fixing peak(R) location in the case of low signal-noise ratio.

  10. In silico prediction of drug therapy in catecholaminergic polymorphic ventricular tachycardia

    PubMed Central

    Yang, Pei‐Chi; Moreno, Jonathan D.; Miyake, Christina Y.; Vaughn‐Behrens, Steven B.; Jeng, Mao‐Tsuen; Grandi, Eleonora; Wehrens, Xander H. T.; Noskov, Sergei Y.

    2016-01-01

    Key points The mechanism of therapeutic efficacy of flecainide for catecholaminergic polymorphic ventricular tachycardia (CPVT) is unclear.Model predictions suggest that Na+ channel effects are insufficient to explain flecainide efficacy in CPVT.This study represents a first step toward predicting therapeutic mechanisms of drug efficacy in the setting of CPVT and then using these mechanisms to guide modelling and simulation to predict alternative drug therapies. Abstract Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome characterized by fatal ventricular arrhythmias in structurally normal hearts during β‐adrenergic stimulation. Current treatment strategies include β‐blockade, flecainide and ICD implementation – none of which is fully effective and each comes with associated risk. Recently, flecainide has gained considerable interest in CPVT treatment, but its mechanism of action for therapeutic efficacy is unclear. In this study, we performed in silico mutagenesis to construct a CPVT model and then used a computational modelling and simulation approach to make predictions of drug mechanisms and efficacy in the setting of CPVT. Experiments were carried out to validate model results. Our simulations revealed that Na+ channel effects are insufficient to explain flecainide efficacy in CPVT. The pure Na+ channel blocker lidocaine and the antianginal ranolazine were additionally tested and also found to be ineffective. When we tested lower dose combination therapy with flecainide, β‐blockade and CaMKII inhibition, our model predicted superior therapeutic efficacy than with flecainide monotherapy. Simulations indicate a polytherapeutic approach may mitigate side‐effects and proarrhythmic potential plaguing CPVT pharmacological management today. Importantly, our prediction of a novel polytherapy for CPVT was confirmed experimentally. Our simulations suggest that flecainide therapeutic efficacy in CPVT is unlikely

  11. Assessment of cardiac autonomic functions by heart rate recovery, heart rate variability and QT dynamicity parameters in patients with acromegaly.

    PubMed

    Dural, Muhammet; Kabakcı, Giray; Cınar, Neşe; Erbaş, Tomris; Canpolat, Uğur; Gürses, Kadri Murat; Tokgözoğlu, Lale; Oto, Ali; Kaya, Ergün Barış; Yorgun, Hikmet; Sahiner, Levent; Dağdelen, Selçuk; Aytemir, Kudret

    2014-04-01

    Cardiovascular complications are the most common causes of morbidity and mortality in acromegaly. However, there is little data regarding cardiac autonomic functions in these patients. Herein, we aimed to investigate several parameters of cardiac autonomic functions in patients with acromegaly compared to healthy subjects. We enrolled 20 newly diagnosed acromegalic patients (55% female, age:45.7 ± 12.6 years) and 32 age- and gender-matched healthy subjects. All participants underwent 24 h Holter recording. Heart rate recovery (HRR) indices were calculated by subtracting 1st, 2nd and 3rd minute heart rates from maximal heart rate. All patients underwent heart rate variability (HRV) and QT dynamicity analysis. Baseline characteristics were similar except diabetes mellitus and hypertension among groups. Mean HRR1 (29.2 ± 12.3 vs 42.6 ± 6.5, p = 0.001), HRR2 (43.5 ± 15.6 vs 61.1 ± 10.8, p = 0.001) and HRR3 (46.4 ± 16.2 vs 65.8 ± 9.8, p = 0.001) values were significantly higher in control group. HRV parameters as, SDNN [standard deviation of all NN intervals] (p = 0.001), SDANN [SD of the 5 min mean RR intervals] (p = 0.001), RMSSD [root square of successive differences in RR interval] (p = 0.001), PNN50 [proportion of differences in successive NN intervals >50 ms] (p = 0.001) and high-frequency [HF] (p = 0.001) were significantly decreased in patients with acromegaly; but low frequency [LF] (p = 0.046) and LF/HF (p = 0.001) were significantly higher in acromegaly patients. QTec (p = 0.009), QTac/RR slope (p = 0.017) and QTec/RR slope (p = 0.01) were significantly higher in patients with acromegaly. Additionally, there were significant negative correlation of disease duration with HRR2, HRR3, SDNN, PNN50, RMSSD, variability index. Our study results suggest that cardiac autonomic functions are impaired in patients with acromegaly. Further large scale studies are needed to exhibit the prognostic significance of impaired autonomic functions in patients with

  12. Heart rate variability based on risk stratification for type 2 diabetes mellitus.

    PubMed

    Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne

    2017-01-01

    To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score

  13. Heart rate-induced modifications of concentric left ventricular hypertrophy: exploration of a novel therapeutic concept.

    PubMed

    Klein, Franziska J; Bell, Stephen; Runte, K Elisabeth; Lobel, Robert; Ashikaga, Takamuru; Lerman, Lilach O; LeWinter, Martin M; Meyer, Markus

    2016-10-01

    Lowering the heart rate is considered to be beneficial in heart failure (HF) with reduced ejection fraction (HFrEF). In a dilated left ventricle (LV), pharmacological heart rate lowering is associated with a reduction in LV chamber size. In patients with HFrEF, this structural change is associated with better survival. HF with preserved ejection fraction (HFpEF) is increasingly prevalent but, so far, without any evidence-based treatment. HFpEF is typically associated with LV concentric remodeling and hypertrophy. The effects of heart rate on this structural phenotype are not known. Analogous with the benefits of a low heart rate on a dilated heart, we hypothesized that increased heart rates could lead to potentially beneficial remodeling of a concentrically hypertrophied LV. This was explored in an established porcine model of concentric LV hypertrophy and fibrosis. Our results suggest that a moderate increase in heart rate can be used to reduce wall thickness, normalize LV chamber volumes, decrease myocardial fibrosis, and improve LV compliance. Our results also indicate that the effects of heart rate can be titrated, are reversible, and do not induce HF. These findings may provide the rationale for a novel therapeutic approach for HFpEF and its antecedent disease substrate. Copyright © 2016 the American Physiological Society.

  14. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    PubMed

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  15. Heart rate variability.

    PubMed

    Cygankiewicz, Iwona; Zareba, Wojciech

    2013-01-01

    Heart rate variability (HRV) provides indirect insight into autonomic nervous system tone, and has a well-established role as a marker of cardiovascular risk. Recent decades brought an increasing interest in HRV assessment as a diagnostic tool in detection of autonomic impairment, and prediction of prognosis in several neurological disorders. Both bedside analysis of simple markers of HRV, as well as more sophisticated HRV analyses including time, frequency domain and nonlinear analysis have been proven to detect early autonomic involvement in several neurological disorders. Furthermore, altered HRV parameters were shown to be related with cardiovascular risk, including sudden cardiac risk, in patients with neurological diseases. This chapter aims to review clinical and prognostic application of HRV analysis in diabetes, stroke, multiple sclerosis, muscular dystrophies, Parkinson's disease and epilepsy. © 2013 Elsevier B.V. All rights reserved.

  16. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    PubMed

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  17. Successful ventricular tachycardia ablation in patients with electrical storm reduces recurrences and improves survival.

    PubMed

    Vergara, Pasquale; Tung, Roderick; Vaseghi, Marmar; Brombin, Chiara; Frankel, David; Di Biase, Luigi; Nagashima, Koichi; Tedrow, Usha; Tzou, Wendy S; Sauer, William H; Mathuria, Nilesh; Nakahara, Shiro; Vakil, Kairav; Tholakanahalli, Venkat; Bunch, T Jared; Weiss, J Peter; Dickfeld, Timm; Vunnam, Rama; Lakireddy, Dhanunjaya; Burkhardt, J David; Correra, Anna; Santangeli, Pasquale; Callans, David; Natale, Andrea; Marchlinski, Francis; Stevenson, William G; Shivkumar, Kalyanam; Della Bella, Paolo

    2018-01-01

    The purpose of this study was to evaluate the characteristics and outcome of patients undergoing ablation after electrical storm (ES). Clinical and procedural characteristics, ventricular tachycardia (VT) recurrence, and mortality rates from 1940 patients undergoing VT ablation were compared between patients with and without ES. The group of 677 patients with ES (34.9%) were older, were more frequently men, and had a lower ejection fraction, more advanced heart failure, and a higher prevalence of cardiovascular comorbidities as compared with those without ES (86.1% patients with ES had ≥2 comorbidities vs 71.4%; P < .001). Patients with ES had more inducible VTs (2.5 ± 1.8 vs 1.9 ± 1.9; P < .001), required longer procedures (296.1 ± 119.1 minutes vs 265.7 ± 110.3 minutes; P < .001), and had a higher in-hospital mortality (42 deaths [6.2%] vs 18 deaths [1.4%]; P < .001). At 1-year follow-up, patients with ES experienced a higher risk of VT recurrence and mortality (32.1% vs 22.6% and 20.1% vs 8.5%; long-rank, P < .001 for both). Among patients with ES, those without any inducible VT after ablation had a higher survival rate (86.3%) than did those with nonclinical VTs only (72.9%), those with clinical VTs inducible at programmed electrical stimulation (51.2%), and not-tested patients (65.0%) (long-rank, P < .001 for all). In multivariate analysis, ES remained an independent predictor of in-hospital mortality, VT recurrence, and 1-year mortality (P < .001). Patients with ES have a high risk of VT recurrence and mortality. Patient and procedure characteristics are consistent with advanced cardiac disease and longer and more complex procedures. In patients with ES, acute procedural success is associated with a significant reduction in VT recurrence and improved 1-year survival. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Ambulatory blood pressure and heart rate during shuttle flight, entry and landing

    NASA Technical Reports Server (NTRS)

    Thornton, W.; Moore, T. P.; Uri, J.

    1993-01-01

    Ambulatory blood pressures (BP) and heart rates (HR) were recorded on a series of early Shuttle flights during preflight and pre-entry, entry, landing and egress. There were no significant differences between flight and preflight values during routine activity. Systolic blood pressure was slightly elevated in the deorbit period and systolic and diastolic blood pressure and heart rates were all elevated with onset of gravitoinertial loads and remained so through egress. Two of seven subjects had orthostatic problems in egress but their data did not show significant differences from others except in heart rate. Comparison of this data to that from recent studies show even larger increase in HR/BP values during current deorbit and entry phases which is consistent with increased heat and weight loads imposed by added survival gear. Both value and limitations of ambulatory heart rate/blood pressure data in this situation are demonstrated.

  19. Systolic time interval v heart rate regression equations using atropine: reproducibility studies.

    PubMed Central

    Kelman, A W; Sumner, D J; Whiting, B

    1981-01-01

    1. Systolic time intervals (STI) were recorded in six normal male subjects over a period of 3 weeks. On one day per week, each subject received incremental doses of atropine intravenously to increase heart rate, allowing the determination of individual STI v HR regression equations. On the other days STI were recorded with the subjects resting, in the supine position. 2. There were highly significant regression relationships between heart rate and both LVET and QS2, but not between heart rate and PEP. 3. The regression relationships showed little intra-subject variability, but a large degree of inter-subject variability: they proved adequate to correct the STI for the daily fluctuations in heart rate. 4. Administration of small doses of atropine intravenously provides a satisfactory and convenient method of deriving individual STI v HR regression equations which can be applied over a period of weeks. PMID:7248136

  20. Systolic time interval v heart rate regression equations using atropine: reproducibility studies.

    PubMed

    Kelman, A W; Sumner, D J; Whiting, B

    1981-07-01

    1. Systolic time intervals (STI) were recorded in six normal male subjects over a period of 3 weeks. On one day per week, each subject received incremental doses of atropine intravenously to increase heart rate, allowing the determination of individual STI v HR regression equations. On the other days STI were recorded with the subjects resting, in the supine position. 2. There were highly significant regression relationships between heart rate and both LVET and QS2, but not between heart rate and PEP. 3. The regression relationships showed little intra-subject variability, but a large degree of inter-subject variability: they proved adequate to correct the STI for the daily fluctuations in heart rate. 4. Administration of small doses of atropine intravenously provides a satisfactory and convenient method of deriving individual STI v HR regression equations which can be applied over a period of weeks.

  1. Association between resting heart rate, metabolic syndrome and cardiorespiratory fitness in Korean male adults.

    PubMed

    Kang, Seol-Jung; Ha, Gi-Chul; Ko, Kwang-Jun

    2017-06-01

    The present study aimed to investigate the association between metabolic syndrome and cardiorespiratory fitness according to resting heart rate of Korean male adults. A total of 11,876 male adults aged 20-65 years who underwent health examinations from 2010 to 2015 at a National Fitness Centre in South Korea were included. Subjects' resting heart rate, cardiorespiratory fitness (VO 2 max), and metabolic syndrome parameters were collected. The subjects were divided into 5 categories (<60 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and ≥90 bpm) of resting heart rate for further analysis. We found that elevated resting heart rate was positively associated with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, and fasting blood glucose levels ( p  < 0.001, respectively); in contrast, elevated resting heart rate was inversely associated with VO 2 max ( p  < 0.001). When resting heart rate of subjects was categorized into quintiles and analysed, the results showed that the relative risk of metabolic syndrome was 1.53-fold higher (95% CI, 1.34 to 1.82) in the range of 60-69 beats per minute (bpm), 2.08-fold higher (95% CI, 1.77 to 2.45) in the range of 70-79 bpm, 2.28-fold higher (95% CI, 1.73 to 3.00) in the range of 80-89 bpm, and 2.61-fold higher (95% CI, 1.62 to 4.20) in the range of ≥90 bpm, compared to those <60 bpm; this indicated that as resting heart rate increased, the relative risk of metabolic syndrome also increased. Resting heart rate of male adults was found to be associated with cardiorespiratory fitness; the risk factors for metabolic syndrome and relative risk of metabolic syndrome increased as resting heart rate increased.

  2. Effects of subchronic exposures to concentrated ambient particles (CAPs) in mice. III. Acute and chronic effects of CAPs on heart rate, heart-rate fluctuation, and body temperature.

    PubMed

    Hwang, Jing-Shiang; Nadziejko, Christine; Chen, Lung Chi

    2005-04-01

    Normal mice (C57) and mice prone to develop atherosclerosis (ApoE-/-) were implanted with electrocardiograph (EKG), core body temperature, and motion transmitters were exposed daily for 6 h to Tuxedo, NY, concentrated ambient particles (CAPs) for 5 day/wk during the spring and summer of 2003. The series of 5-min EKG monitoring and body-temperature measurements were obtained for each animal in the CAPs and filtered air sham exposure groups. Our hypothesis was that chronic exposure could cause cumulative health effects. We used our recently developed nonparametric method to estimate the daily time periods that mean heart rates (HR), body temperature, and physical activity differed significantly between the CAPs and sham exposed group. CAPs exposure most affected heart rate between 1:30 a.m. and 4:30 a.m. With the response variables being the average heart rate, body temperature, and physical activity, we adopted a two-stage modeling approach to obtain the estimates of chronic and acute effects on the changes of these three response variables. In the first stage, a time-varying model estimated daily crude effects. In the second stage, the true means of the estimated crude effects were modeled with a polynominal function of time for chronic effects, a linear term of daily CAPs exposure concentrations for acute effects, and a random component for unknown noise. A Bayesian framework combined these two stages. There were significant decreasing patterns of HR, body temperature, and physical activity for the ApoE-/- mice over the 5 mo of CAPs exposure, with smaller and nonsignificant changes for the C57 mice. The chronic effect changes of the three response variables for ApoE-/- mice were maximal in the last few weeks. There was also a significant relationship between CAPs exposure concentration and short-term changes of heart rate in ApoE-/- mice during exposure. Response variables were also defined for examining fluctuations of 5-min heart rates within long (i.e., 3-6 h

  3. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    NASA Astrophysics Data System (ADS)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  4. Clinical and Electrocardiographic Characteristics of Electrical Storms Due to Monomorphic Ventricular Tachycardia Refractory to Intravenous Amiodarone.

    PubMed

    Murata, Hiroshige; Miyauchi, Yasushi; Hayashi, Meiso; Iwasaki, Yu-Ki; Yodogawa, Kenji; Ueno, Akira; Hayashi, Hiroshi; Tsuboi, Ippei; Uetake, Shunsuke; Takahashi, Kenta; Yamamoto, Teppei; Maruyama, Mitsunori; Akutsu, Koichi; Yamamoto, Takeshi; Kobayashi, Yoshinori; Tanaka, Keiji; Atarashi, Hirotsugu; Katoh, Takao; Shimizu, Wataru

    2015-01-01

    Few reports are available on the characteristics of electrical storms of ventricular tachycardia (VT storm) refractory to intravenous (IV) amiodarone. IV-amiodarone was administered to 60 patients with ventricular tachyarrhythmia between 2007 and 2012. VT storms, defined as 3 or more episodes of VT within 24 h, occurred in 30 patients (68±12 years, 7 female), with 12 having ischemic and 18 non-ischemic heart disease. We compared the clinical and electrocardiographic characteristics of the patients with VT storms suppressed by IV-amiodarone (Effective group) to those of patients not affected by the treatment (Refractory group). IV-amiodarone could not control recurrence of VT in 9 patients (30%). The Refractory group comprised 5 patients with acute myocardial infarctions. Although there was no difference in the VT cycle length, the QRS duration of both the VT and premature ventricular contractions (PVCs) followed by VT was narrower in the Refractory group than in the Effective group (140±30 vs. 178±25 ms, P<0.01; 121±14 vs. 179±22 ms, P<0.01). In the Refractory group, additional administration of IV-mexiletine and/or Purkinje potential-guided catheter ablation was effective. IV-amiodarone-refractory VT exhibited a relatively narrow QRS tachycardia. The narrow triggering PVCs, suggesting a Purkinje fiber origin, may be treated by additional IV-mexiletine and endocardial catheter ablation.

  5. Radiofrequency ablation versus cryoablation for atrioventricular nodal re-entrant tachycardia in children: a value comparison.

    PubMed

    Oster, Matthew E; Yang, Zhou; Stewart-Huey, Kay; Glanville, Michelle; Porter, Arlene; Campbell, Robert; Webb, Brad; Strieper, Margaret

    2017-03-01

    It is unclear whether cryoablation or radiofrequency ablation offers better value for treating atrioventricular nodal re-entrant tachycardia in children. We aimed to compare the value of these procedures for treating atrioventricular nodal re-entrant tachycardia in children, with value being outcomes relative to costs. We performed a retrospective cohort study of all atrioventricular nodal re-entrant tachycardia ablations for children (age⩽18 years) from July, 2009 to June, 2011 at our institution. Costs included fixed costs, miscellaneous hospital costs, and labour costs, and key outcomes were acute and long-term success (6 months) of the ablations. We conducted T-tests and regression analyses to investigate the associations between the ablation procedure type and the cost and success of the ablations. Of 96 unique cases performed by three paediatric electrophysiologists, 48 were cryoablation only, 42 radiofrequency ablation only, and six were a combination. Acute success was 100% for the cryoablation only and radiofrequency ablation only cases and 83% for the combination cases. There were no notable adverse events. The average total cost was $9636 for cryoablation cases, $9708 for radiofrequency ablation cases, and $10,967 for combination cases (p=0.51 for cryoablation only versus radiofrequency ablation only). The long-term success rate was 79.1% for cryoablation only, 92.8% for radiofrequency ablation only, and 66.7% for the combination (p=0.01 for cryoablation only versus radiofrequency ablation only), but long-term success varied notably by provider. Cryoablation and radiofrequency ablation offer similar value in the short term for the treatment of atrioventricular nodal re-entrant tachycardia in children. Differences in long-term success may vary substantially by physician, and thus may lead to differences in long-term value.

  6. Remote Measurements of Heart and Respiration Rates for Telemedicine

    PubMed Central

    Qian, Yi; Tsien, Joe Z.

    2013-01-01

    Non-contact and low-cost measurements of heart and respiration rates are highly desirable for telemedicine. Here, we describe a novel technique to extract blood volume pulse and respiratory wave from a single channel images captured by a video camera for both day and night conditions. The principle of our technique is to uncover the temporal dynamics of heart beat and breathing rate through delay-coordinate transformation and independent component analysis-based deconstruction of the single channel images. Our method further achieves robust elimination of false positives via applying ratio-variation probability distributions filtering approaches. Moreover, it enables a much needed low-cost means for preventing sudden infant death syndrome in new born infants and detecting stroke and heart attack in elderly population in home environments. This noncontact-based method can also be applied to a variety of animal model organisms for biomedical research. PMID:24115996

  7. Long-term follow-up of implantable cardioverter-defibrillators in adult congenital heart disease patients: indications and outcomes.

    PubMed

    Santharam, Sandhya; Hudsmith, Lucy; Thorne, Sara; Clift, Paul; Marshall, Howard; De Bono, Joseph

    2017-03-01

    Ventricular arrhythmias are a major cause of mortality in adult congenital heart disease (ACHD) patients. The European Society of Cardiology guidelines state that implantable cardioverter-defibrillators (ICD) should be considered in patients with congenital heart disease following spontaneous sustained ventricular tachycardia (VT) or cardiac arrest and in patients at presumed high risk. This study sought to analyse the circumstances in which ACHD patients received ICD and to assess outcomes of ICD implantation, including therapies delivered and the rate of complications. A retrospective review was performed of all adult patients with congenital heart disease undergoing ICD implant between 2000 and 2014, in a large quaternary referral centre with over 4000 adults with congenital heart disease under active follow-up. Demographics: 42 patients with congenital heart disease had ICD implants: 55% male; age range 21-71 years and mean age 45 years. Mean age at implantation of ICD was 41 years. Mean follow-up was 5 years. Diagnosis: 50% of patients had repaired tetralogy of Fallot (TOF). Twelve per cent of patients had repaired transposition of the great arteries. Reason for ICD: 15 patients (35.7%) received ICD after sustained VT. Eleven patients (26.2%) received ICD after cardiac arrest. Sixteen (38%) had ICD implanted as primary prophylaxis. Outcome: Since implantation, six patients received an appropriate full-output shock for VT from ICD. Nineteen (45%) patients suffered significant complications (inappropriate shocks 11, inappropriate anti-tachycardia pacing resulting in VF 1, infection requiring extraction 3, lead abnormalities 3, and pneumothorax 1). Equal proportions of primary and secondary prevention patients received appropriate shocks. Most patients had ICD for secondary prevention (62%), and the majority had repaired TOF. There was a 2.9% annual appropriate shock rate. However, there was a high incidence of complications with more than a third suffering a

  8. [Current status and recommendations for intrapartum monitoring of fetal heart rate].

    PubMed

    Měchurová, A; Velebil, P; Hruban, L; Janků, P

    2016-04-01

    Monitoring of fetal heart rate is one of the basic components of obstetrical care, in which the cardiotocography remains the gold standard and screening method in early diagnosis of fetal hypoxia, even after introduction of other selective methods of intrauterine monitoring of fetal well-being. The review article is divided into several parts: pathophysiology of fetal oxygenation, fetal heart rate and changes of fetal hemodynamics, and rules for fetal heart rate auscultation. The main principles of cardiotocographic monitoring and evaluation of ante- and intrapartrum recordings according to the FIGO criteria from 1986 and evaluation of intrapartum recordings according to the 2015 FIGO recommendations are mentioned. At the end a comparative table of 1986 FIGO and 2015 FIGO criteria is presented. Review.

  9. Transfer entropy analysis of maternal and fetal heart rate coupling.

    PubMed

    Marzbanrad, Faezeh; Kimura, Yoshitaka; Endo, Miyuki; Palaniswami, Marimuthu; Khandoker, Ahsan H

    2015-01-01

    Although evidence of the short term relationship between maternal and fetal heart rates has been found in previous model-based studies, knowledge about the mechanism and patterns of the coupling during gestation is still limited. In this study, a model-free method based on Transfer Entropy (TE) was applied to quantify the maternal-fetal heart rate couplings in both directions. Furthermore, analysis of the lag at which TE was maximum and its changes throughout gestation, provided more information about the mechanism of coupling and its latency. Experimental results based on fetal electrocardiograms (fECGs) and maternal ECG showed the evidence of coupling for 62 out of 65 healthy mothers and fetuses in each direction, by statistically validating against the surrogate pairs. The fetuses were divided into three gestational age groups: early (16-25 weeks), mid (26-31 weeks) and late (32-41 weeks) gestation. The maximum TE from maternal to fetal heart rate significantly increased from early to mid gestation, while the coupling delay on both directions decreased significantly from mid to late gestation. These changes occur concomitant with the maturation of the fetal sensory and autonomic nervous systems with advancing gestational age. In conclusion, the application of TE with delays revealed detailed information about the changes in fetal-maternal heart rate coupling strength and latency throughout gestation, which could provide novel clinical markers of fetal development and well-being.

  10. Determination of heart rate variability with an electronic stethoscope.

    PubMed

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  11. Comparative Efficacy of Nebivolol and Metoprolol to Prevent Tachycardia-Induced Cardiomyopathy in a Porcine Model.

    PubMed

    Nazeri, Alireza; Elayda, MacArthur A; Segura, Ana Maria; Stainback, Raymond F; Nathan, Joanna; Lee, Vei-Vei; Bove, Christina; Sampaio, Luiz; Grace, Brian; Massumi, Ali; Razavi, Mehdi

    2016-12-01

    Chronic tachycardia is a well-known cause of nonischemic cardiomyopathy. We hypothesized that nebivolol, a β-blocker with nitric oxide activity, would be superior to a pure β-blocker in preventing tachycardia-induced cardiomyopathy in a porcine model. Fifteen healthy Yucatan pigs were randomly assigned to receive nebivolol, metoprolol, or placebo once a day. All pigs underwent dual-chamber pacemaker implantation. The medication was started the day after the pacemaker implantation. On day 7 after implantation, each pacemaker was set at atrioventricular pace (rate, 170 beats/min), and the pigs were observed for another 7 weeks. Transthoracic echocardiograms, serum catecholamine levels, and blood chemistry data were obtained at baseline and at the end of the study. At the end of week 8, the pigs were euthanized, and complete histopathologic studies were performed. All the pigs developed left ventricular cardiomyopathy but remained hemodynamically stable and survived to the end of the study. The mean left ventricular ejection fraction decreased from baseline by 34%, 20%, and 20% in the nebivolol, metoprolol, and placebo groups, respectively. These changes did not differ significantly among the 3 groups ( P =0.51). Histopathologic analysis revealed mild left ventricular perivascular fibrosis with cardiomyocyte hypertrophy in 14 of the 15 pigs. Both nebivolol and metoprolol failed to prevent cardiomyopathy in our animal model of persistent tachycardia and a high catecholamine state.

  12. Congenital heart disease infant death rates decrease as gestational age advances from 34 to 40 weeks.

    PubMed

    Cnota, James F; Gupta, Resmi; Michelfelder, Erik C; Ittenbach, Richard F

    2011-11-01

    To describe congenital heart disease death rates in infants born between 34 and 40 weeks, estimate the relationship between gestational age and congenital heart disease infant death rates, and compare congenital heart disease death rates across 1- and 2-week intervals in gestational age. The 2000 to 2003 national linked birth/infant death cohort datasets were obtained. Congenital heart disease deaths were identified by using International Statistical Classification of Diseases, 10th Revision codes. Proportional death rates were calculated by using congenital heart disease deaths and all live births. The relationship between congenital heart disease death rates and gestational age was determined. Death rates were compared across intervals. A total of 14.9 million records were analyzed. Congenital heart disease deaths occurred in 4736 infants (0.04%) born between 34 and 40 weeks. There was a significant, negative linear relationship between congenital heart disease death rate and gestational age (R(2) = 0.97). Comparisons across 1-week intervals varied (P = .02-.23). All 2-week intervals were statistically significant (P < .01). Congenital heart disease death rates decrease as gestational age approaches 40 weeks. These results should be considered before elective delivery for the sole indication of prenatally diagnosed congenital heart disease. Copyright © 2011 Mosby, Inc. All rights reserved.

  13. Fitbit Charge HR Wireless Heart Rate Monitor: Validation Study Conducted Under Free-Living Conditions.

    PubMed

    Gorny, Alexander Wilhelm; Liew, Seaw Jia; Tan, Chuen Seng; Müller-Riemenschneider, Falk

    2017-10-20

    Many modern smart watches and activity trackers feature an optical sensor that estimates the wearer's heart rate. Recent studies have evaluated the performance of these consumer devices in the laboratory. The objective of our study was to examine the accuracy and sensitivity of a common wrist-worn tracker device in measuring heart rates and detecting 1-min bouts of moderate to vigorous physical activity (MVPA) under free-living conditions. Ten healthy volunteers were recruited from a large university in Singapore to participate in a limited field test, followed by a month of continuous data collection. During the field test, each participant would wear one Fitbit Charge HR activity tracker and one Polar H6 heart rate monitor. Fitbit measures were accessed at 1-min intervals, while Polar readings were available for 10-s intervals. We derived intraclass correlation coefficients (ICCs) for individual participants comparing heart rate estimates. We applied Centers for Disease Control and Prevention heart rate zone cut-offs to ascertain the sensitivity and specificity of Fitbit in identifying 1-min epochs falling into MVPA heart rate zone. We collected paired heart rate data for 2509 1-min epochs in 10 individuals under free-living conditions of 3 to 6 hours. The overall ICC comparing 1-min Fitbit measures with average 10-s Polar H6 measures for the same epoch was .83 (95% CI .63-.91). On average, the Fitbit tracker underestimated heart rate measures by -5.96 bpm (standard error, SE=0.18). At the low intensity heart rate zone, the underestimate was smaller at -4.22 bpm (SE=0.15). This underestimate grew to -16.2 bpm (SE=0.74) in the MVPA heart rate zone. Fitbit devices detected 52.9% (192/363) of MVPA heart rate zone epochs correctly. Positive and negative predictive values were 86.1% (192/223) and 92.52% (2115/2286), respectively. During subsequent 1 month of continuous data collection (270 person-days), only 3.9% of 1-min epochs could be categorized as MVPA according

  14. Heart rate changes in partial seizures: analysis of influencing factors among refractory patients

    PubMed Central

    2014-01-01

    Background We analyzed the frequency of heart rate (HR) changes related to seizures, and we sought to identify the influencing factors of these changes during partial seizures, to summarize the regularity of the HR changes and gain some insight into the mechanisms involved in the neuronal regulation of cardiovascular function. To date, detailed information on influencing factors of HR changes related to seizures by multiple linear regression analysis remains scarce. Methods Using video-electroencephalograph (EEG)-electrocardiograph (ECG) recordings, we retrospectively assessed the changes in the HR of 81 patients during a total of 181 seizures, including 27 simple partial seizures (SPS), 110 complex partial seizures (CPS) and 44 complex partial seizures secondarily generalized (CPS-G). The epileptogenic focus and the seizure type, age, gender, and sleep/wakefulness state of each patient were evaluated during and after the seizure onset. The HR changes were evaluated in the stage of epilepsy as time varies. Results Of the 181 seizures from 81 patients with ictal ECGs, 152 seizures (83.98%) from 74 patients were accompanied by ictal tachycardia (IT). And only 1 patient was accompanied by ictal bradycardia (IB). A patient has both IT and IB. We observed that HR difference was independently correlated with side, type and sleep/wakefulness state. In this analysis, the HR changes were related to the side, gender, seizure type, and sleep/wakefulness state. Right focus, male, sleep, and CPS-G showed more significant increases than that were observed in left, female, wakefulness, SPS and CPS. HR increases rapidly within 10 seconds before seizure onset and ictus, and typically slows to normal with seizure offset. Conclusion CPS-G, sleep and right focus led to higher ictal HR. The HR in the stage of epilepsy has regularly been observed to change to become time-varying. The risk factors of ictal HR need to be controlled along with sleep, CPS-G and right focus. Our study first

  15. Analysis of long term heart rate variability: methods, 1/f scaling and implications

    NASA Technical Reports Server (NTRS)

    Saul, J. P.; Albrecht, P.; Berger, R. D.; Cohen, R. J.

    1988-01-01

    The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.

  16. Ventricular, but not atrial, M2-muscarinic receptors increase in the canine pacing-overdrive model of heart failure.

    PubMed

    Wilkinson, M; Giles, A; Armour, J A; Cardinal, R

    1996-01-01

    To investigate the effects of heart failure induced by chronic rapid ventricular pacing (six weeks) on canine atrial and ventricular muscarinic receptors. Dogs (n = 4) were fitted with a bipolar pacing electrode connected to a Medtronic pacemaker set at 240 stimuli/min. Pacing was maintained for six weeks. Tissue samples obtained from the left atrium and ventral wall of the left ventricle were frozen at -70 degrees C. Control tissue was obtained from normal dogs (n = 6) following anesthesia and thoracotomy. M2-muscarinic receptors were characterized and quantified in tissue micropunches using the hydrophilic ligand [3H] N-methyl-scopolamine (NMS). Cardiac tissue bound [3H] NMS with the specificity of an M2 subtype. Tachycardia-induced heart failure did not affect atrial muscarinic receptors but signify left ventricular myocytes (control 160.0 +/- 10.0 fmol/mg protein versus heart failure 245.0 +/- 25.0 fmol/mg protein; P < 0.01). Canine ventricular muscarinic receptors display a specificity for the M2 subtype. In contrast to previous work, tachycardia-induced heart failure was accompanied by an increase (+ 53%) in ventricular, but not atrial, M2 receptors compared with normal dogs.

  17. Single delivery of an adeno-associated viral construct to transfer the CASQ2 gene to knock-in mice affected by catecholaminergic polymorphic ventricular tachycardia is able to cure the disease from birth to advanced age.

    PubMed

    Denegri, Marco; Bongianino, Rossana; Lodola, Francesco; Boncompagni, Simona; De Giusti, Verónica C; Avelino-Cruz, José E; Liu, Nian; Persampieri, Simone; Curcio, Antonio; Esposito, Francesca; Pietrangelo, Laura; Marty, Isabelle; Villani, Laura; Moyaho, Alejandro; Baiardi, Paola; Auricchio, Alberto; Protasi, Feliciano; Napolitano, Carlo; Priori, Silvia G

    2014-06-24

    Catecholaminergic polymorphic ventricular tachycardia is an inherited arrhythmogenic disorder characterized by sudden cardiac death in children. Drug therapy is still insufficient to provide full protection against cardiac arrest, and the use of implantable defibrillators in the pediatric population is limited by side effects. There is therefore a need to explore the curative potential of gene therapy for this disease. We investigated the efficacy and durability of viral gene transfer of the calsequestrin 2 (CASQ2) wild-type gene in a catecholaminergic polymorphic ventricular tachycardia knock-in mouse model carrying the CASQ2(R33Q/R33Q) (R33Q) mutation. We engineered an adeno-associated viral vector serotype 9 (AAV9) containing cDNA of CASQ2 wild-type (AAV9-CASQ2) plus the green fluorescent protein (GFP) gene to infect newborn R33Q mice studied by in vivo and in vitro protocols at 6, 9, and 12 months to investigate the ability of the infection to prevent the disease and adult R33Q mice studied after 2 months to assess whether the AAV9-CASQ2 delivery could revert the catecholaminergic polymorphic ventricular tachycardia phenotype. In both protocols, we observed the restoration of physiological expression and interaction of CASQ2, junctin, and triadin; the rescue of electrophysiological and ultrastructural abnormalities in calcium release units present in R33Q mice; and the lack of life-threatening arrhythmias. Our data demonstrate that viral gene transfer of wild-type CASQ2 into the heart of R33Q mice prevents and reverts severe manifestations of catecholaminergic polymorphic ventricular tachycardia and that this curative effect lasts for 1 year after a single injection of the vector, thus posing the rationale for the design of a clinical trial. © 2014 American Heart Association, Inc.

  18. Surgical ablation of ventricular tachycardia secondary to congenital ventricular septal aneurysm.

    PubMed

    Graffigna, A; Minzioni, G; Ressia, L; Vigano, M

    1994-04-01

    Three patients underwent surgical ablation for ventricular tachycardia resulting from an aneurysm of the membranous portion of the ventricular septum. Two patients had a definite history of cardiac murmur during infancy, and one of them was found at the time of operation to have a left-to-right shunt through the apex of the aneurysm. The earliest ventricular activation sites were located around the neck of the aneurysm and were ablated in 1 patient by encircling the endocardial ventriculotomy and by cryoablation in the remaining 2. After focus resection had been completed, aneurysm resection and ventricular septal reconstruction were performed. All patients were alive and free of ventricular tachycardia and did not need medication as of 61, 66, and 88 months postoperatively. Spontaneous closure of a ventricular septal defect may lead to the formation of an aneurysm in the ventricular septum that may sustain ventricular tachycardias. Such arrhythmias can be effectively treated using electrically guided surgical techniques.

  19. Heart rate profiles and energy cost of locomotion during cross-country skiing races.

    PubMed

    Mognoni, P; Rossi, G; Gastaldelli, F; Canclini, A; Cotelli, F

    2001-07-01

    The purpose of this study was to compare heart rate responses and speed in two cross-country skiing races, which were run by seven male and seven female subjects by using classic and free style. Heart rates and skiing velocities were analyzed over flat, uphill and downhill sections, which were run from one to three times. Heart rates were higher in uphill sections than in flat sections; a steady-state heart rate was never reached in the downhill section. When the same uphill section was repeated, the heart rate tended to increase but the speed to decrease. Oxygen uptake (VO2) was calculated from heart rate:VO2 ratio, measured during uphill walking with the aid of poles. The mean (SD) energy cost of locomotion (i.e., the ratio between net VO2 and speed) was 162.1 (9.4) ml.km(-1).kg(-1) and 147.7 (7.1) ml.km(-1).kg(-1) when male subjects ran the flat section after first downhill by using classic and free style, respectively. Females had lower values for VO2 and speed, but similar energy costs. In general, the variability of the energy cost of locomotion in skiers of a similar competitive level is of the same order as that found in uphill walking on a treadmill.

  20. Zebrafish heart as a model to study the integrative autonomic control of pacemaker function

    PubMed Central

    Stoyek, Matthew R.; Quinn, T. Alexander; Croll, Roger P.

    2016-01-01

    The cardiac pacemaker sets the heart's primary rate, with pacemaker discharge controlled by the autonomic nervous system through intracardiac ganglia. A fundamental issue in understanding the relationship between neural activity and cardiac chronotropy is the identification of neuronal populations that control pacemaker cells. To date, most studies of neurocardiac control have been done in mammalian species, where neurons are embedded in and distributed throughout the heart, so they are largely inaccessible for whole-organ, integrative studies. Here, we establish the isolated, innervated zebrafish heart as a novel alternative model for studies of autonomic control of heart rate. Stimulation of individual cardiac vagosympathetic nerve trunks evoked bradycardia (parasympathetic activation) and tachycardia (sympathetic activation). Simultaneous stimulation of both vagosympathetic nerve trunks evoked a summative effect. Effects of nerve stimulation were mimicked by direct application of cholinergic and adrenergic agents. Optical mapping of electrical activity confirmed the sinoatrial region as the site of origin of normal pacemaker activity and identified a secondary pacemaker in the atrioventricular region. Strong vagosympathetic nerve stimulation resulted in a shift in the origin of initial excitation from the sinoatrial pacemaker to the atrioventricular pacemaker. Putative pacemaker cells in the sinoatrial and atrioventricular regions expressed adrenergic β2 and cholinergic muscarinic type 2 receptors. Collectively, we have demonstrated that the zebrafish heart contains the accepted hallmarks of vertebrate cardiac control, establishing this preparation as a viable model for studies of integrative physiological control of cardiac function by intracardiac neurons. PMID:27342878

  1. Deep-Diving California Sea Lions: Are They Pushing Their Physiological Limit

    DTIC Science & Technology

    2015-09-30

    resting heart rate (70 bpm ) (Ponganis et al. 1997) is reached, and e) duration of and heart rate during the ascent tachycardia. If possible, heart rate...Resting heart rates were 54 + 6 beats min-1 ( bpm ), and in dives of 1-3 min, 3-5 min, and > 5 min, dive heart rates (number of beats/dive duration...were 55 + 8, 51 + 6, and 40 + bpm . As illustrated in Figs. 1 and 2, the heart rate profile was characterized by rapid development of a bradycardia

  2. Vagal Nerve Stimulation Evoked Heart Rate Changes and Protection from Cardiac Remodeling.

    PubMed

    Agarwal, Rahul; Mokelke, Eric; Ruble, Stephen B; Stolen, Craig M

    2016-02-01

    This study investigated whether vagal nerve stimulation (VNS) leads to improvements in ischemic heart failure via heart rate modulation. At 7 ± 1 days post left anterior descending artery (LAD) ligation, 63 rats with myocardial infarctions (MI) were implanted with ECG transmitters and VNS devices (MI + VNS, N = 44) or just ECG transmitters (MI, N = 17). VNS stimulation was active from 14 ± 1 days to 8 ± 1 weeks post MI. The average left ventricular (LV) end diastolic volumes at 8 ± 1 weeks were MI = 672.40 μl and MI + VNS = 519.35 μl, p = 0.03. The average heart weights, normalized to body weight (± std) at 14 ± 1 weeks were MI = 3.2 ± 0.6 g*kg(-1) and MI + VNS = 2.9 ± 0.3 g*kg(-1), p = 0.03. The degree of cardiac remodeling was correlated with the magnitude of acute VNS-evoked heart rate (HR) changes. Further research is required to determine if the acute heart rate response to VNS activation is useful as a heart failure biomarker or as a tool for VNS therapy characterization.

  3. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise.

    PubMed

    Sadeghi, Masoumeh; Gharipour, Mojgan; Nezafati, Pouya; Shafie, Davood; Aghababaei, Esmaeil; Sarrafzadegan, Nizal

    2016-11-01

    The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS) patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III) definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5%) were diagnosed as MetS. The mean resting heart rate (RHR) was not statistically different between the two groups (P=0.078). However, the mean maximum heart (MHR) rate was considerably higher in participants with MetS (142.37±14.84 beats per min) compared to the non-MetS group (134.62±21.63 beats per min) (P<0.001). In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033) and was inversely associated with age (β=-0.469, P<0.001). The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004) with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  4. When an Increase in Central Systolic Pressure Overrides the Benefits of Heart Rate Lowering.

    PubMed

    Messerli, Franz H; Rimoldi, Stefano F; Bangalore, Sripal; Bavishi, Chirag; Laurent, Stephane

    2016-08-16

    An elevated resting heart rate has been unequivocally linked to adverse cardiovascular events. Conversely, a physiologically low heart rate may confer longevity benefits. Moreover, pharmacological heart rate lowering reduces cardiovascular outcomes in patients with heart failure, with the magnitude of the reduction associated with survival benefit. In contrast, pharmacological heart rate lowering paradoxically increases cardiovascular events in hypertension, possibly because it elicits a ventricular-vascular mismatch, leading to increased central systolic blood pressure (BP). By the same hemodynamic mechanism, pharmacological heart rate lowering also engenders an increase in central (aortic) BP in coronary heart disease and, as a consequence, fails to decrease myocardial oxygen consumption. Whether in heart failure, hypertension, or coronary heart disease, or even athletes, heart rate lowering consistently increases central systolic pressure. The increase in central systolic BP is prone to abolish the potential benefits of heart rate lowering interventions, possibly accounting for failure to reduce outcomes in patients with hypertension and coronary artery disease. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Possible role for cryoballoon ablation of right atrial appendage tachycardia when conventional ablation fails.

    PubMed

    Amasyali, Basri; Kilic, Ayhan

    2015-06-01

    Focal atrial tachycardia arising from the right atrial appendage usually responds well to radiofrequency ablation; however, successful ablation in this anatomic region can be challenging. Surgical excision of the right atrial appendage has sometimes been necessary to eliminate the tachycardia and prevent or reverse the resultant cardiomyopathy. We report the case of a 48-year-old man who had right atrial appendage tachycardia resistant to multiple attempts at ablation with use of conventional radiofrequency energy guided by means of a 3-dimensional mapping system. The condition led to cardiomyopathy in 3 months. The arrhythmia was successfully ablated with use of a 28-mm cryoballoon catheter that had originally been developed for catheter ablation of paroxysmal atrial fibrillation. To our knowledge, this is the first report of cryoballoon ablation without isolation of the right atrial appendage. It might also be an alternative to epicardial ablation or surgery when refractory atrial tachycardia originates from the right atrial appendage.

  6. [Design of hand-held heart rate variability acquisition and analysis system].

    PubMed

    Li, Kaiyuan; Wang, Buqing; Wang, Weidong

    2012-07-01

    A design of handheld heart rate variability acquisition and analysis system is proposed. The system collects and stores the patient's ECG every five minutes through both hands touching on the electrodes, and then -uploads data to a PC through USB port. The system uses software written in LabVIEW to analyze heart rate variability parameters, The parameters calculated function is programmed and generated to components in Matlab.

  7. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure.

    PubMed

    Turianikova, Zuzana; Javorka, Kamil; Baumert, Mathias; Calkovska, Andrea; Javorka, Michal

    2011-09-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1-10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change.

  8. Monitoring the fetal heart rate variability during labor.

    PubMed

    Moslem, B; Mohydeen, A; Bazzi, O

    2015-08-01

    In respect to the main goal of our ongoing work for estimating the heart rate variability (HRV) from fetal electrocardiogram (FECG) signals for monitoring the health of the fetus, we investigate in this paper the possibility of extracting the fetal heart rate variability (HRV) directly from the abdominal composite recordings. Our proposed approach is based on a combination of two techniques: Periodic Component Analysis (PiCA) and recursive least square (RLS) adaptive filtering. The Fetal HRV of the estimated FECG signal is compared to a reference value extracted from an FECG signal recorded by using a spiral electrode attached directly to the fetal scalp. The results obtained show that the fetal HRV can be directly evaluated from the abdominal composite recordings without the need of recording an external reference signal.

  9. Robust efficient estimation of heart rate pulse from video.

    PubMed

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-04-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity.

  10. Robust efficient estimation of heart rate pulse from video

    PubMed Central

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-01-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294

  11. Modeling of Diffusion Based Correlations Between Heart Rate Modulations and Respiration Pattern

    DTIC Science & Technology

    2001-10-25

    1 of 4 MODELING OF DIFFUSION BASED CORRELATIONS BETWEEN HEART RATE MODULATIONS AND RESPIRATION PATTERN R.Langer,(1) Y.Smorzik,(2) S.Akselrod,(1...generations of the bronchial tree. The second stage describes the oxygen diffusion process from the pulmonary gas in the alveoli into the pulmonary...patterns (FRC, TV, rate). Keywords – Modeling, Diffusion , Heart Rate fluctuations I. INTRODUCTION Under a whole-body management perception, the

  12. Pulse transducer with artifact signal attenuator. [heart rate sensors

    NASA Technical Reports Server (NTRS)

    Cash, W. H., Jr.; Polhemus, J. T. (Inventor)

    1980-01-01

    An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

  13. Post-exercise heart rate recovery independently predicts mortality risk in patients with chronic heart failure.

    PubMed

    Tang, Yi-Da; Dewland, Thomas A; Wencker, Detlef; Katz, Stuart D

    2009-12-01

    Post-exercise heart rate recovery (HRR) is an index of parasympathetic function associated with clinical outcomes in populations with and without documented coronary heart disease. Decreased parasympathetic activity is thought to be associated with disease progression in chronic heart failure (HF), but an independent association between post-exercise HRR and clinical outcomes among such patients has not been established. We measured HRR (calculated as the difference between heart rate at peak exercise and after 1 minute of recovery) in 202 HF subjects and recorded 17 mortality and 15 urgent transplantation outcome events over 624 days of follow-up. Reduced post-exercise HRR was independently associated with increased event risk after adjusting for other exercise-derived variables (peak oxygen uptake and change in minute ventilation per change in carbon dioxide production slope), for the Heart Failure Survival Score (adjusted HR 1.09 for 1 beat/min reduction, 95% CI 1.05-1.13, P < .0001), and the Seattle Heart Failure Model score (adjusted HR 1.08 for one beat/min reduction, 95% CI 1.05-1.12, P < .0001). Subjects in the lowest risk tertile based on post-exercise HRR (>or=30 beats/min) had low risk of events irrespective of the risk predicted by the survival scores. In a subgroup of 15 subjects, reduced post-exercise HRR was associated with increased serum markers of inflammation (interleukin-6, r = 0.58, P = .024; high-sensitivity C-reactive protein, r = 0.66, P = .007). Post-exercise HRR predicts mortality risk in patients with HF and provides prognostic information independent of previously described survival models. Pathophysiologic links between autonomic function and inflammation may be mediators of this association.

  14. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    PubMed

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  15. Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program

    ERIC Educational Resources Information Center

    Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John

    2011-01-01

    We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…

  16. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    PubMed

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  17. Development of porcine model of chronic tachycardia-induced cardiomyopathy.

    PubMed

    Paslawska, Urszula; Gajek, Jacek; Kiczak, Liliana; Noszczyk-Nowak, Agnieszka; Skrzypczak, Piotr; Bania, Jacek; Tomaszek, Alicja; Zacharski, Maciej; Sambor, Izabela; Dziegiel, Piotr; Zysko, Dorota; Banasiak, Waldemar; Jankowska, Ewa A; Ponikowski, Piotr

    2011-11-17

    There are few experimental models of heart failure (HF) in large animals, despite structural and functional similarities to human myocardium. We have developed a porcine model of chronic tachycardia-induced cardiomyopathy. Homogenous siblings of White Large breed swine (n=6) underwent continuous right ventricular (RV) pacing at 170 bpm; 2 subjects served as controls. In the course of RV pacing, animals developed a clinical picture of HF and were presented for euthanasia at subsequent stages: mild, moderate and end-stage HF. Left ventricle (LV) sections were analyzed histologically and relative ANP, BNP, phospholamban and sarcoplasmic reticulum calcium ATPase 2a transcript levels in LV were quantified by real time RT-PCR. In the course of RV pacing, animals demonstrated reduced exercise capacity (time of running until being dyspnoeic: 6.6 ± 0.5 vs. 2.4 ± 1.4 min), LV dilatation (LVEDD: 4.9 ± 0.4 vs. 6.7 ± 0.4 cm), impaired LV systolic function (LVEF: 69 ± 8 vs. 32 ± 7 %), (all baseline vs. before euthanasia, all p<0.001). LV tissues from animals with moderate and end-stage HF demonstrated local foci of interstitial fibrosis, congestion, cardiomyocyte hypertrophy and atrophy, which was not detected in controls and mild HF animals. The up-regulation of ANP and BNP and a reduction in a ratio of sarcoplasmic reticulum calcium ATPase 2a and phospholamban in failing myocardium were observed as compared to controls. In pigs, chronic RV pacing at relatively low rate can be used as an experimental model of HF, as it results in a gradual deterioration of exercise tolerance accompanied by myocardial remodeling confirmed at subcellular level. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Left Septal Slow Pathway Ablation for Atrioventricular Nodal Reentrant Tachycardia.

    PubMed

    Katritsis, Demosthenes G; John, Roy M; Latchamsetty, Rakesh; Muthalaly, Rahul G; Zografos, Theodoros; Katritsis, George D; Stevenson, William G; Efimov, Igor R; Morady, Fred

    2018-03-01

    Immunohistochemistry studies suggest that the anatomic substrate of the slow pathway in atrioventricular nodal reentrant tachycardia (AVNRT) is the left inferior nodal extension. We hypothesized that slow pathway ablation from the left septum is an effective alternative to right-sided ablation. We analyzed our databases of AVNRT in search of cases that had used slow pathway ablation from the left septum because of failure of right septal ablation, and then prospectively subjected consenting patients to a left septal-only procedure. Of 1342 patients subjected to right septal slow pathway ablation for AVNRT, 15 patients, 11 with typical and 4 with atypical AVNRT, had a left septal approach after unsuccessful right-sided ablation (R+L group). Eleven patients were subjected to a left septal-only approach for slow pathway ablation without a previous right septal attempt (L group). Fluoroscopy times in the R+L and L groups were 30.5 (21.0-44.0) and 20.0 (17.0-25.0) minutes, respectively ( P =0.061), and radiofrequency current delivery times were 11.3 (5.0-19.1) and 10.0 (7.0-12.0) minutes, respectively ( P =0.897). There was no need for additional ablation lesions at other anatomic sites in either group, and no cases of atrioventricular block were encountered. Recurrence rates of the arrhythmia for the R+L and L groups were 6.7% and 0%, respectively, in the 3 months after ablation ( P =1.000). Left septal ablation at the anatomic site of the left inferior nodal extension is an alternative for ablation of both typical and atypical AVNRT when ablation at the right posterior septum is ineffective. © 2018 American Heart Association, Inc.

  19. Arrhythmogenic Mechanisms in a Mouse Model of Catecholaminergic Polymorphic Ventricular Tachycardia

    PubMed Central

    Cerrone, Marina; Noujaim, Sami F.; Tolkacheva, Elena G.; Talkachou, Arkadzi; O’Connell, Ryan; Berenfeld, Omer; Anumonwo, Justus; Pandit, Sandeep V.; Vikstrom, Karen; Napolitano, Carlo; Priori, Silvia G.; Jalife, José

    2008-01-01

    Catecholaminergic polymorphic ventricular tachycardia (VT) is a lethal familial disease characterized by bidirectional VT, polymorphic VT, and ventricular fibrillation. Catecholaminergic polymorphic VT is caused by enhanced Ca2+ release through defective ryanodine receptor (RyR2) channels. We used epicardial and endocardial optical mapping, chemical subendocardial ablation with Lugol’s solution, and patch clamping in a knockin (RyR2/RyR2R4496C) mouse model to investigate the arrhythmogenic mechanisms in catecholaminergic polymorphic VT. In isolated hearts, spontaneous ventricular arrhythmias occurred in 54% of 13 RyR2/RyR2R4496C and in 9% of 11 wild-type (P=0.03) littermates perfused with Ca2+ and isoproterenol; 66% of 12 RyR2/RyR2R4496C and 20% of 10 wild-type hearts perfused with caffeine and epinephrine showed arrhythmias (P=0.04). Epicardial mapping showed that monomorphic VT, bidirectional VT, and polymorphic VT manifested as concentric epicardial breakthrough patterns, suggesting a focal origin in the His–Purkinje networks of either or both ventricles. Monomorphic VT was clearly unifocal, whereas bidirectional VT was bifocal. Polymorphic VT was initially multifocal but eventually became reentrant and degenerated into ventricular fibrillation. Endocardial mapping confirmed the Purkinje fiber origin of the focal arrhythmias. Chemical ablation of the right ventricular endocardial cavity with Lugol’s solution induced complete right bundle branch block and converted the bidirectional VT into monomorphic VT in 4 anesthetized RyR2/RyR2R4496C mice. Under current clamp, single Purkinje cells from RyR2/RyR2R4496C mouse hearts generated delayed afterdepolarization–induced triggered activity at lower frequencies and level of adrenergic stimulation than wild-type. Overall, the data demonstrate that the His–Purkinje system is an important source of focal arrhythmias in catecholaminergic polymorphic VT. PMID:17872467

  20. Office and 24-hour heart rate and target organ damage in hypertensive patients

    PubMed Central

    2012-01-01

    Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male). Heart rate (HR) and its standard deviation (HRV) in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033) and night/day systolic blood pressure ratio (OR = 1.425 and 1.512). Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064 PMID:22439900