Sample records for tactile illusory movement

  1. Active Manual Movement Improves Directional Perception of Illusory Force.

    PubMed

    Amemiya, Tomohiro; Gomi, Hiroaki

    2016-01-01

    Active touch sensing is known to facilitate the discrimination or recognition of the spatial properties of an object from the movement of tactile sensors on the skin and by integrating proprioceptive feedback about hand positions or motor commands related to ongoing hand movements. On the other hand, several studies have reported that tactile processing is suppressed by hand movement. Thus, it is unclear whether or not the active exploration of force direction by using hand or arm movement improves the perception of the force direction. Here, we show that active manual movement in both the rotational and translational directions enhances the precise perception of the force direction. To make it possible to move a hand in space without any physical constraints, we have adopted a method of inducing the sensation of illusory force by asymmetric vibration. We found that the precision of the perceived force direction was significantly better when the shoulder is rotated medially and laterally. We also found that directional errors supplied by the motor response of the perceived force were smaller than those resulting from perceptual judgments between visual and haptic directional stimuli. These results demonstrate that active manual movement boosts the precision of the perceived direction of an illusory force.

  2. Crossing the Hands Increases Illusory Self-Touch

    PubMed Central

    Pozeg, Polona; Rognini, Giulio; Salomon, Roy; Blanke, Olaf

    2014-01-01

    Manipulation of hand posture, such as crossing the hands, has been frequently used to study how the body and its immediately surrounding space are represented in the brain. Abundant data show that crossed arms posture impairs remapping of tactile stimuli from somatotopic to external space reference frame and deteriorates performance on several tactile processing tasks. Here we investigated how impaired tactile remapping affects the illusory self-touch, induced by the non-visual variant of the rubber hand illusion (RHI) paradigm. In this paradigm blindfolded participants (Experiment 1) had their hands either uncrossed or crossed over the body midline. The strength of illusory self-touch was measured with questionnaire ratings and proprioceptive drift. Our results showed that, during synchronous tactile stimulation, the strength of illusory self-touch increased when hands were crossed compared to the uncrossed posture. Follow-up experiments showed that the increase in illusion strength was not related to unfamiliar hand position (Experiment 2) and that it was equally strengthened regardless of where in the peripersonal space the hands were crossed (Experiment 3). However, while the boosting effect of crossing the hands was evident from subjective ratings, the proprioceptive drift was not modulated by crossed posture. Finally, in contrast to the illusion increase in the non-visual RHI, the crossed hand postures did not alter illusory ownership or proprioceptive drift in the classical, visuo-tactile version of RHI (Experiment 4). We argue that the increase in illusory self-touch is related to misalignment of somatotopic and external reference frames and consequently inadequate tactile-proprioceptive integration, leading to re-weighting of the tactile and proprioceptive signals.The present study not only shows that illusory self-touch can be induced by crossing the hands, but importantly, that this posture is associated with a stronger illusion. PMID:24699795

  3. Linkage between Free Exploratory Movements and Subjective Tactile Ratings.

    PubMed

    Yokosaka, Takumi; Kuroki, Scinob; Watanabe, Junji; Nishida, Shinya

    2017-01-01

    We actively move our hands and eyes when exploring the external world and gaining information about object's attributes. Previous studies showing that how we touch might be related to how we felt led us to consider whether we could decode observers' subjective tactile experiences only by analyzing their exploratory movements without explicitly asking how they perceived. However, in those studies, explicit judgment tasks were performed about specific tactile attributes that were prearranged by experimenters. Here, we systematically investigated whether exploratory movements can explain tactile ratings even when participants do not need to judge any tactile attributes. While measuring both hand and eye movements, we asked participants to touch materials freely without judging any specific tactile attributes (free-touch task) or to evaluate one of four tactile attributes (roughness, hardness, slipperiness, and temperature). We found that tactile ratings in the judgment tasks correlated with exploratory movements even in the free-touch task and that eye movements as well as hand movements correlated with tactile ratings. These results might open up the possibility of decoding tactile experiences by exploratory movements.

  4. Optimal visuotactile integration for velocity discrimination of self-hand movements

    PubMed Central

    Chancel, M.; Blanchard, C.; Guerraz, M.; Montagnini, A.

    2016-01-01

    Illusory hand movements can be elicited by a textured disk or a visual pattern rotating under one's hand, while proprioceptive inputs convey immobility information (Blanchard C, Roll R, Roll JP, Kavounoudias A. PLoS One 8: e62475, 2013). Here, we investigated whether visuotactile integration can optimize velocity discrimination of illusory hand movements in line with Bayesian predictions. We induced illusory movements in 15 volunteers by visual and/or tactile stimulation delivered at six angular velocities. Participants had to compare hand illusion velocities with a 5°/s hand reference movement in an alternative forced choice paradigm. Results showed that the discrimination threshold decreased in the visuotactile condition compared with unimodal (visual or tactile) conditions, reflecting better bimodal discrimination. The perceptual strength (gain) of the illusions also increased: the stimulation required to give rise to a 5°/s illusory movement was slower in the visuotactile condition compared with each of the two unimodal conditions. The maximum likelihood estimation model satisfactorily predicted the improved discrimination threshold but not the increase in gain. When we added a zero-centered prior, reflecting immobility information, the Bayesian model did actually predict the gain increase but systematically overestimated it. Interestingly, the predicted gains better fit the visuotactile performances when a proprioceptive noise was generated by covibrating antagonist wrist muscles. These findings show that kinesthetic information of visual and tactile origins is optimally integrated to improve velocity discrimination of self-hand movements. However, a Bayesian model alone could not fully describe the illusory phenomenon pointing to the crucial importance of the omnipresent muscle proprioceptive cues with respect to other sensory cues for kinesthesia. PMID:27385802

  5. The effect of chronic low back pain on tactile suppression during back movements.

    PubMed

    Van Damme, Stefaan; Van Hulle, Lore; Danneels, Lieven; Spence, Charles; Crombez, Geert

    2014-10-01

    The aim of the present study was to examine whether tactile suppression, the phenomenon whereby tactile perception is suppressed during movement, would occur in the context of back movements. Of particular interest, it was investigated if tactile suppression in the back would be attenuated in those suffering from chronic low back pain. Individuals with chronic low back pain (N = 30) and a matched control group (N = 24) detected tactile stimuli on three possible locations (back, arm, chest) while performing a back or arm movement, or no movement. We hypothesized that the movements would induce tactile suppression, and that this effect would be largest for low-intense stimuli on the moving body part. We further hypothesized that, during back movements, tactile suppression on the back would be less pronounced in the chronic low back pain group than in the control group. The results showed the expected general tactile suppression effects. The hypothesis of back-specific attenuation of tactile suppression in the chronic low back pain group was not supported. However, back-specific tactile suppression in the chronic low back pain group was less pronounced in those who performed the back movements more slowly. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. The tactile movement aftereffect.

    PubMed

    Hollins, M; Favorov, O

    1994-01-01

    The existence of a tactile movement aftereffect was established in a series of experiments on the palmar surface of the hand and fingers of psychophysical observers. During adaptation, observers cupped their hand around a moving drum for up to 3 min; following this period of stimulation, they typically reported an aftereffect consisting of movement sensations located on and deep to the skin, and lasting for up to 1 min. Preliminary experiments comparing a number of stimulus materials mounted on the drum demonstrated that a surface approximating a low-spatial-frequency square wave, with a smooth microtexture, was especially effective at inducing the aftereffect; this adapting stimulus was therefore used throughout the two main experiments. In Experiment 1, the vividness of the aftereffect produced by 2 min of adaptation was determined under three test conditions: with the hand (1) remaining on the now stationary drum; (2) in contact with a soft, textured surface; or (3) suspended in air. Subjects' free magnitude estimates of the peak vividness of the aftereffect were not significantly different across conditions; each subject experienced the aftereffect at least once under each condition. Thus the tactile movement aftereffect does not seem to depend critically on the ponditions of stimulation that obtain while it is being experienced. In Experiment 2, the vividness and duration of the aftereffect were measured as a function of the duration of the adapting stimulus. Both measures increased steadily over the range of durations explored (30-180 sec). In its dependence on adapting duration, the aftereffect resembles the waterfall illusion in vision. An explanation for the tactile movement aftereffect is proposed, based on the model of cortical dynamics of Whitsel et al. (1989, 1991). With assumed modest variation of one parameter across individuals, this application of the model is able to account both for the data of the majority of subjects, who experienced the

  7. Illusory movement perception improves motor control for prosthetic hands

    PubMed Central

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  8. Neural correlates of tactile perception during pre-, peri-, and post-movement.

    PubMed

    Juravle, Georgiana; Heed, Tobias; Spence, Charles; Röder, Brigitte

    2016-05-01

    Tactile information is differentially processed over the various phases of goal-directed movements. Here, event-related potentials (ERPs) were used to investigate the neural correlates of tactile and visual information processing during movement. Participants performed goal-directed reaches for an object placed centrally on the table in front of them. Tactile and visual stimulation (100 ms) was presented in separate trials during the different phases of the movement (i.e. preparation, execution, and post-movement). These stimuli were independently delivered to either the moving or resting hand. In a control condition, the participants only performed the movement, while omission (i.e. movement-only) ERPs were recorded. Participants were instructed to ignore the presence or absence of any sensory events and to concentrate solely on the execution of the movement. Enhanced ERPs were observed 80-200 ms after tactile stimulation, as well as 100-250 ms after visual stimulation: These modulations were greatest during the execution of the goal-directed movement, and they were effector based (i.e. significantly more negative for stimuli presented to the moving hand). Furthermore, ERPs revealed enhanced sensory processing during goal-directed movements for visual stimuli as well. Such enhanced processing of both tactile and visual information during the execution phase suggests that incoming sensory information is continuously monitored for a potential adjustment of the current motor plan. Furthermore, the results reported here also highlight a tight coupling between spatial attention and the execution of motor actions.

  9. Illusory movement perception improves motor control for prosthetic hands.

    PubMed

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  10. Illusory body ownership of an invisible body interpolated between virtual hands and feet via visual-motor synchronicity.

    PubMed

    Kondo, Ryota; Sugimoto, Maki; Minamizawa, Kouta; Hoshi, Takayuki; Inami, Masahiko; Kitazaki, Michiteru

    2018-05-15

    Body ownership can be modulated through illusory visual-tactile integration or visual-motor synchronicity/contingency. Recently, it has been reported that illusory ownership of an invisible body can be induced by illusory visual-tactile integration from a first-person view. We aimed to test whether a similar illusory ownership of the invisible body could be induced by the active method of visual-motor synchronicity and if the illusory invisible body could be experienced in front of and facing away from the observer. Participants observed left and right white gloves and socks in front of them, at a distance of 2 m, in a virtual room through a head-mounted display. The white gloves and socks were synchronized with the observers' actions. In the experiments, we tested the effect of synchronization, and compared this to a whole-body avatar, measuring self-localization drift. We observed that visual hands and feet were sufficient to induce illusory body ownership, and this effect was as strong as using a whole-body avatar.

  11. Spatiotemporal integration for tactile localization during arm movements: a probabilistic approach.

    PubMed

    Maij, Femke; Wing, Alan M; Medendorp, W Pieter

    2013-12-01

    It has been shown that people make systematic errors in the localization of a brief tactile stimulus that is delivered to the index finger while they are making an arm movement. Here we modeled these spatial errors with a probabilistic approach, assuming that they follow from temporal uncertainty about the occurrence of the stimulus. In the model, this temporal uncertainty converts into a spatial likelihood about the external stimulus location, depending on arm velocity. We tested the prediction of the model that the localization errors depend on arm velocity. Participants (n = 8) were instructed to localize a tactile stimulus that was presented to their index finger while they were making either slow- or fast-targeted arm movements. Our results confirm the model's prediction that participants make larger localization errors when making faster arm movements. The model, which was used to fit the errors for both slow and fast arm movements simultaneously, accounted very well for all the characteristics of these data with temporal uncertainty in stimulus processing as the only free parameter. We conclude that spatial errors in dynamic tactile perception stem from the temporal precision with which tactile inputs are processed.

  12. Voluntary movement affects simultaneous perception of auditory and tactile stimuli presented to a non-moving body part.

    PubMed

    Hao, Qiao; Ora, Hiroki; Ogawa, Ken-Ichiro; Ogata, Taiki; Miyake, Yoshihiro

    2016-09-13

    The simultaneous perception of multimodal sensory information has a crucial role for effective reactions to the external environment. Voluntary movements are known to occasionally affect simultaneous perception of auditory and tactile stimuli presented to the moving body part. However, little is known about spatial limits on the effect of voluntary movements on simultaneous perception, especially when tactile stimuli are presented to a non-moving body part. We examined the effect of voluntary movement on the simultaneous perception of auditory and tactile stimuli presented to the non-moving body part. We considered the possible mechanism using a temporal order judgement task under three experimental conditions: voluntary movement, where participants voluntarily moved their right index finger and judged the temporal order of auditory and tactile stimuli presented to their non-moving left index finger; passive movement; and no movement. During voluntary movement, the auditory stimulus needed to be presented before the tactile stimulus so that they were perceived as occurring simultaneously. This subjective simultaneity differed significantly from the passive movement and no movement conditions. This finding indicates that the effect of voluntary movement on simultaneous perception of auditory and tactile stimuli extends to the non-moving body part.

  13. Visual enhancing of tactile perception in the posterior parietal cortex.

    PubMed

    Ro, Tony; Wallace, Ruth; Hagedorn, Judith; Farnè, Alessandro; Pienkos, Elizabeth

    2004-01-01

    The visual modality typically dominates over our other senses. Here we show that after inducing an extreme conflict in the left hand between vision of touch (present) and the feeling of touch (absent), sensitivity to touch increases for several minutes after the conflict. Transcranial magnetic stimulation of the posterior parietal cortex after this conflict not only eliminated the enduring visual enhancement of touch, but also impaired normal tactile perception. This latter finding demonstrates a direct role of the parietal lobe in modulating tactile perception as a result of the conflict between these senses. These results provide evidence for visual-to-tactile perceptual modulation and demonstrate effects of illusory vision of touch on touch perception through a long-lasting modulatory process in the posterior parietal cortex.

  14. Illusory bending of a rigidly moving line segment: effects of image motion and smooth pursuit eye movements.

    PubMed

    Thaler, Lore; Todd, James T; Spering, Miriam; Gegenfurtner, Karl R

    2007-04-20

    Four experiments in which observers judged the apparent "rubberiness" of a line segment undergoing different types of rigid motion are reported. The results reveal that observers perceive illusory bending when the motion involves certain combinations of translational and rotational components and that the illusion is maximized when these components are presented at a frequency of approximately 3 Hz with a relative phase angle of approximately 120 degrees . Smooth pursuit eye movements can amplify or attenuate the illusion, which is consistent with other results reported in the literature that show effects of eye movements on perceived image motion. The illusion is unaffected by background motion that is in counterphase with the motion of the line segment but is significantly attenuated by background motion that is in-phase. This is consistent with the idea that human observers integrate motion signals within a local frame of reference, and it provides strong evidence that visual persistency cannot be the sole cause of the illusion as was suggested by J. R. Pomerantz (1983). An analysis of the motion patterns suggests that the illusory bending motion may be due to an inability of observers to accurately track the motions of features whose image displacements undergo rapid simultaneous changes in both space and time. A measure of these changes is presented, which is highly correlated with observers' numerical ratings of rubberiness.

  15. Importance of human right inferior frontoparietal network connected by inferior branch of superior longitudinal fasciculus tract in corporeal awareness of kinesthetic illusory movement.

    PubMed

    Amemiya, Kaoru; Naito, Eiichi

    2016-05-01

    It is generally believed that the human right cerebral hemisphere plays a dominant role in corporeal awareness, which is highly associated with conscious experience of the physical self. Prompted by our previous findings, we examined whether the right frontoparietal activations often observed when people experience kinesthetic illusory limb movement are supported by a large-scale brain network connected by a specific branch of the superior longitudinal fasciculus fiber tracts (SLF I, II, and III). We scanned brain activity with functional magnetic resonance imaging (MRI) while nineteen blindfolded healthy volunteers experienced illusory movement of the right stationary hand elicited by tendon vibration, which was replicated after the scanning. We also scanned brain activity when they executed and imagined right hand movement, and identified the active brain regions during illusion, execution, and imagery in relation to the SLF fiber tracts. We found that illusion predominantly activated the right inferior frontoparietal regions connected by SLF III, which were not substantially recruited during execution and imagery. Among these regions, activities in the right inferior parietal cortices and inferior frontal cortices showed right-side dominance and correlated well with the amount of illusion (kinesthetic illusory awareness) experienced by the participants. The results illustrated the predominant involvement of the right inferior frontoparietal network connected by SLF III when people recognize postural changes of their limb. We assume that the network bears a series of functions, specifically, monitoring the current status of the musculoskeletal system, and building-up and updating our postural model (body schema), which could be a basis for the conscious experience of the physical self. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Visual illusion of tool use recalibrates tactile perception

    PubMed Central

    Miller, Luke E.; Longo, Matthew R.; Saygin, Ayse P.

    2018-01-01

    Brief use of a tool recalibrates multisensory representations of the user’s body, a phenomenon called tool embodiment. Despite two decades of research, little is known about its boundary conditions. It has been widely argued that embodiment requires active tool use, suggesting a critical role for somatosensory and motor feedback. The present study used a visual illusion to cast doubt on this view. We used a mirror-based setup to induce a visual experience of tool use with an arm that was in fact stationary. Following illusory tool use, tactile perception was recalibrated on this stationary arm, and with equal magnitude as physical use. Recalibration was not found following illusory passive tool holding, and could not be accounted for by sensory conflict or general interhemispheric plasticity. These results suggest visual tool-use signals play a critical role in driving tool embodiment. PMID:28196765

  17. The effect of motor control and tactile acuity training on patients with non-specific low back pain and movement control impairment.

    PubMed

    Gutknecht, Magdalena; Mannig, Angelika; Waldvogel, Anja; Wand, Benedict M; Luomajoki, Hannu

    2015-10-01

    Movement control impairment is a clinical subgroup of non-specific low back pain which can be assessed reliably. There is a strong correlation between tactile acuity and movement control suggesting these two treatments might have additive effects. The first research aim was to determine if patients with a motor control impairment demonstrated improvement in outcome with combined tactile acuity and motor control training. The second aim was to determine if tactile acuity training enhanced the effect of motor control training. The primary study was a single-arm cohort study conducted in three physiotherapy practices in the German-speaking part of Switzerland. 40 patients (23 males and 17 females) suffering from non-specific low back pain (NSLBP) and movement control impairment were treated. Patients were assessed at baseline and immediately post treatment. Treatment included exercises to lumbopelvic control and graphesthesia training to improve tactile acuity. Treatment effects were evaluated using the Roland Morris disability questionnaire (RMQ) and the patient-specific functional scale (PSFS). The performance on a set of six movement control tests and lumbar two-point discrimination were also assessed. The results of this cohort study were compared with a historic control group which was comparable with the primary study but included only motor control exercises. All the outcomes improved significantly with the combined training (RMQ - 2.2 pts., PSFS - 2.8 pts.; MCTB - 2.02 pts. & TPD - 17.07 mm; all p < 0.05). In comparison to the outcomes of the historic control, there was no significant differences in movement control, patient-specific functional complaints or disability between the groups. The results of this study, based on a before and after intervention comparison, showed that outcome improved significantly following combined tactile acuity and motor control training. However, compared to an earlier study, the tactile acuity training did not have an

  18. Temporal coupling due to illusory movements in bimanual actions: evidence from anosognosia for hemiplegia.

    PubMed

    Pia, Lorenzo; Spinazzola, Lucia; Rabuffetti, Marco; Ferrarin, Maurizio; Garbarini, Francesca; Piedimonte, Alessandro; Driver, Jon; Berti, Anna

    2013-06-01

    In anosognosia for hemiplegia, patients may claim having performed willed actions with the paralyzed limb despite unambiguous evidence to the contrary. Does this false belief of having moved reflect the functioning of the same mechanisms that govern normal motor performance? Here, we examined whether anosognosics show the same temporal constraints known to exist during bimanual movements in healthy subjects. In these paradigms, when participants simultaneously reach for two targets of different difficulties, the motor programs of one hand affect the execution of the other. In detail, the movement time of the hand going to an easy target (i.e., near and large), while the other is going to a difficult target (i.e., far and small), is slowed with respect to unimanual movements (temporal coupling effect). One right-brain-damaged patient with left hemiplegia and anosognosia, six right-brain-damaged patients with left hemiplegia without anosognosia, and twenty healthy subjects were administered such a bimanual task. We recorded the movement times for easy and difficult targets, both in unimanual (one target) and bimanual (two targets) conditions. We found that, as healthy subjects, the anosognosic patient showed coupling effect. In bimanual asymmetric conditions (when one hand went to the easy target and the other went to the difficult target), the movement time of the non-paralyzed hand going to the easy target was slowed by the 'pretended' movement of the paralyzed hand going to the difficult target. This effect was not present in patients without anosognosia. We concluded that in anosognosic patients, the illusory movements of the paralyzed hand impose to the non-paralyzed hand the same motor constraints that emerge during the actual movements. Our data also support the view that coupling relies on central operations (i.e., activation of intention/programming system), rather than on online information from the periphery. Copyright © 2012 Elsevier Ltd. All rights

  19. Cross-modal illusory conjunctions between vision and touch.

    PubMed

    Cinel, Caterina; Humphreys, Glyn W; Poli, Riccardo

    2002-10-01

    Cross-modal illusory conjunctions (ICs) happen when, under conditions of divided attention, felt textures are reported as being seen or vice versa. Experiments provided evidence for these errors, demonstrated that ICs are more frequent if tactile and visual stimuli are in the same hemispace, and showed that ICs still occur under forced-choice conditions but do not occur when attention to the felt texture is increased. Cross-modal ICs were also found in a patient with parietal damage even with relatively long presentations of visual stimuli. The data are consistent with there being cross-modal integration of sensory information, with the modality of origin sometimes being misattributed when attention is constrained. The empirical conclusions from the experiments are supported by formal models.

  20. The magnetic touch illusion: A perceptual correlate of visuo-tactile integration in peripersonal space.

    PubMed

    Guterstam, Arvid; Zeberg, Hugo; Özçiftci, Vedat Menderes; Ehrsson, H Henrik

    2016-10-01

    To accurately localize our limbs and guide movements toward external objects, the brain must represent the body and its surrounding (peripersonal) visual space. Specific multisensory neurons encode peripersonal space in the monkey brain, and neurobehavioral studies have suggested the existence of a similar representation in humans. However, because peripersonal space lacks a distinct perceptual correlate, its involvement in spatial and bodily perception remains unclear. Here, we show that applying brushstrokes in mid-air at some distance above a rubber hand-without touching it-in synchrony with brushstrokes applied to a participant's hidden real hand results in the illusory sensation of a "magnetic force" between the brush and the rubber hand, which strongly correlates with the perception of the rubber hand as one's own. In eight experiments, we characterized this "magnetic touch illusion" by using quantitative subjective reports, motion tracking, and behavioral data consisting of pointing errors toward the rubber hand in an intermanual pointing task. We found that the illusion depends on visuo-tactile synchrony and exhibits similarities with the visuo-tactile receptive field properties of peripersonal space neurons, featuring a non-linear decay at 40cm that is independent of gaze direction and follows changes in the rubber hand position. Moreover, the "magnetic force" does not penetrate physical barriers, thus further linking this phenomenon to body-specific visuo-tactile integration processes. These findings provide strong support for the notion that multisensory integration within peripersonal space underlies bodily self-attribution. Furthermore, we propose that the magnetic touch illusion constitutes a perceptual correlate of visuo-tactile integration in peripersonal space. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  1. Illusory object motion in the centre of a radial pattern: The Pursuit–Pursuing illusion

    PubMed Central

    Ito, Hiroyuki

    2012-01-01

    A circular object placed in the centre of a radial pattern consisting of thin sectors was found to cause a robust motion illusion. During eye-movement pursuit of a moving target, the presently described stimulus produced illusory background-object motion in the same direction as that of the eye movement. In addition, the display induced illusory stationary perception of a moving object against the whole display motion. In seven experiments, the characteristics of the illusion were examined in terms of luminance relationships and figural characteristics of the radial pattern. Some potential explanations for these findings are discussed. PMID:23145267

  2. Illusory object motion in the centre of a radial pattern: The Pursuit-Pursuing illusion.

    PubMed

    Ito, Hiroyuki

    2012-01-01

    A circular object placed in the centre of a radial pattern consisting of thin sectors was found to cause a robust motion illusion. During eye-movement pursuit of a moving target, the presently described stimulus produced illusory background-object motion in the same direction as that of the eye movement. In addition, the display induced illusory stationary perception of a moving object against the whole display motion. In seven experiments, the characteristics of the illusion were examined in terms of luminance relationships and figural characteristics of the radial pattern. Some potential explanations for these findings are discussed.

  3. Surface texture can bias tactile form perception.

    PubMed

    Nakatani, Masashi; Howe, Robert D; Tachi, Susumu

    2011-01-01

    The sense of touch is believed to provide a reliable perception of the object's properties; however, our tactile perceptions could be illusory at times. A recently reported tactile illusion shows that a raised form can be perceived as indented when it is surrounded by textured areas. This phenomenon suggests that the form perception can be influenced by the surface textures in its adjacent areas. As perception of texture and that of form have been studied independently of each other, the present study examined whether textures, in addition to the geometric edges, contribute to the tactile form perception. We examined the perception of the flat and raised contact surface (3.0 mm width) with various heights (0.1, 0.2, 0.3 mm), which had either textured or non-textured adjacent areas, under the static, passive and active touch conditions. Our results showed that texture decreased the raised perception of the surface with a small height (0.1 mm) and decreased the flat perception of the physically flat surface under the passive and active touch conditions. We discuss a possible mechanism underlying the effect of the textures on the form perception based on previous neurophysiological findings.

  4. Using visuo-kinetic virtual reality to induce illusory spinal movement: the MoOVi Illusion

    PubMed Central

    Smith, Ross T.; Hunter, Estin V.; Davis, Miles G.; Sterling, Michele; Moseley, G. Lorimer

    2017-01-01

    Background Illusions that alter perception of the body provide novel opportunities to target brain-based contributions to problems such as persistent pain. One example of this, mirror therapy, uses vision to augment perceived movement of a painful limb to treat pain. Since mirrors can’t be used to induce augmented neck or other spinal movement, we aimed to test whether such an illusion could be achieved using virtual reality, in advance of testing its potential therapeutic benefit. We hypothesised that perceived head rotation would depend on visually suggested movement. Method In a within-subjects repeated measures experiment, 24 healthy volunteers performed neck movements to 50o of rotation, while a virtual reality system delivered corresponding visual feedback that was offset by a factor of 50%–200%—the Motor Offset Visual Illusion (MoOVi)—thus simulating more or less movement than that actually occurring. At 50o of real-world head rotation, participants pointed in the direction that they perceived they were facing. The discrepancy between actual and perceived direction was measured and compared between conditions. The impact of including multisensory (auditory and visual) feedback, the presence of a virtual body reference, and the use of 360o immersive virtual reality with and without three-dimensional properties, was also investigated. Results Perception of head movement was dependent on visual-kinaesthetic feedback (p = 0.001, partial eta squared = 0.17). That is, altered visual feedback caused a kinaesthetic drift in the direction of the visually suggested movement. The magnitude of the drift was not moderated by secondary variables such as the addition of illusory auditory feedback, the presence of a virtual body reference, or three-dimensionality of the scene. Discussion Virtual reality can be used to augment perceived movement and body position, such that one can perform a small movement, yet perceive a large one. The MoOVi technique tested here

  5. Using visuo-kinetic virtual reality to induce illusory spinal movement: the MoOVi Illusion.

    PubMed

    Harvie, Daniel S; Smith, Ross T; Hunter, Estin V; Davis, Miles G; Sterling, Michele; Moseley, G Lorimer

    2017-01-01

    Illusions that alter perception of the body provide novel opportunities to target brain-based contributions to problems such as persistent pain. One example of this, mirror therapy, uses vision to augment perceived movement of a painful limb to treat pain. Since mirrors can't be used to induce augmented neck or other spinal movement, we aimed to test whether such an illusion could be achieved using virtual reality, in advance of testing its potential therapeutic benefit. We hypothesised that perceived head rotation would depend on visually suggested movement. In a within-subjects repeated measures experiment, 24 healthy volunteers performed neck movements to 50 o of rotation, while a virtual reality system delivered corresponding visual feedback that was offset by a factor of 50%-200%-the Motor Offset Visual Illusion (MoOVi)-thus simulating more or less movement than that actually occurring. At 50 o of real-world head rotation, participants pointed in the direction that they perceived they were facing. The discrepancy between actual and perceived direction was measured and compared between conditions. The impact of including multisensory (auditory and visual) feedback, the presence of a virtual body reference, and the use of 360 o immersive virtual reality with and without three-dimensional properties, was also investigated. Perception of head movement was dependent on visual-kinaesthetic feedback ( p  = 0.001, partial eta squared = 0.17). That is, altered visual feedback caused a kinaesthetic drift in the direction of the visually suggested movement. The magnitude of the drift was not moderated by secondary variables such as the addition of illusory auditory feedback, the presence of a virtual body reference, or three-dimensionality of the scene. Virtual reality can be used to augment perceived movement and body position, such that one can perform a small movement, yet perceive a large one. The MoOVi technique tested here has clear potential for assessment and

  6. Gating of tactile information through gamma band during passive arm movement in awake primates

    PubMed Central

    Song, Weiguo; Francis, Joseph T.

    2015-01-01

    To make precise and prompt action in a dynamic environment, the sensorimotor system needs to integrate all related information. The inflow of somatosensory information to the cerebral cortex is regulated and mostly suppressed by movement, which is commonly referred to as sensory gating or gating. Sensory gating plays an important role in preventing redundant information from reaching the cortex, which should be considered when designing somatosensory neuroprosthetics. Gating can occur at several levels within the sensorimotor pathway, while the underlying mechanism is not yet fully understood. The average sensory evoked potential is commonly used to assess sensory information processing, however the assumption of a stereotyped response to each stimulus is still an open question. Event related spectral perturbation (ERSP), which is the power spectrum after time-frequency decomposition on single trial evoked potentials (total power), could overcome this limitation of averaging and provide additional information for understanding the underlying mechanism. To this aim, neural activities in primary somatosensory cortex (S1), primary motor cortex (M1), and ventral posterolateral (VPL) nucleus of thalamus were recorded simultaneously in two areas (S1 and M1 or S1 and VPL) during passive arm movement and rest in awake monkeys. Our results showed that neural activity at different recording areas demonstrated specific and unique response frequency characteristics. Tactile input induced early high frequency responses followed by low frequency oscillations within sensorimotor circuits, and passive movement suppressed these oscillations either in a phase-locked or non-phase-locked manner. Sensory gating by movement was non-phase-locked in M1, and complex in sensory areas. VPL showed gating of non-phase-locked at gamma band and mix of phase-locked and non-phase-locked at low frequency, while S1 showed gating of phase-locked and non-phase-locked at gamma band and an early phase

  7. Use of tactile feedback to control exploratory movements to characterize object compliance.

    PubMed

    Su, Zhe; Fishel, Jeremy A; Yamamoto, Tomonori; Loeb, Gerald E

    2012-01-01

    Humans have been shown to be good at using active touch to perceive subtle differences in compliance. They tend to use highly stereotypical exploratory strategies, such as applying normal force to a surface. We developed similar exploratory and perceptual algorithms for a mechatronic robotic system (Barrett arm/hand system) equipped with liquid-filled, biomimetic tactile sensors (BioTac(®) from SynTouch LLC). The distribution of force on the fingertip was measured by the electrical resistance of the conductive liquid trapped between the elastomeric skin and a cluster of four electrodes on the flat fingertip surface of the rigid core of the BioTac. These signals provided closed-loop control of exploratory movements, while the distribution of skin deformations, measured by more lateral electrodes and by the hydraulic pressure, were used to estimate material properties of objects. With this control algorithm, the robot plus tactile sensor was able to discriminate the relative compliance of various rubber samples.

  8. Perception of self-tilt in a true and illusory vertical plane

    NASA Technical Reports Server (NTRS)

    Groen, Eric L.; Jenkin, Heather L.; Howard, Ian P.; Oman, C. M. (Principal Investigator)

    2002-01-01

    A tilted furnished room can induce strong visual reorientation illusions in stationary subjects. Supine subjects may perceive themselves upright when the room is tilted 90 degrees so that the visual polarity axis is kept aligned with the subject. This 'upright illusion' was used to induce roll tilt in a truly horizontal, but perceptually vertical, plane. A semistatic tilt profile was applied, in which the tilt angle gradually changed from 0 degrees to 90 degrees, and vice versa. This method produced larger illusory self-tilt than usually found with static tilt of a visual scene. Ten subjects indicated self-tilt by setting a tactile rod to perceived vertical. Six of them experienced the upright illusion and indicated illusory self-tilt with an average gain of about 0.5. This value is smaller than with true self-tilt (0.8), but comparable to the gain of visually induced self-tilt in erect subjects. Apparently, the contribution of nonvisual cues to gravity was independent of the subject's orientation to gravity itself. It therefore seems that the gain of visually induced self-tilt is smaller because of lacking, rather than conflicting, nonvisual cues. A vector analysis is used to discuss the results in terms of relative sensory weightings.

  9. An Adaptation-Induced Repulsion Illusion in Tactile Spatial Perception

    PubMed Central

    Li, Lux; Chan, Arielle; Iqbal, Shah M.; Goldreich, Daniel

    2017-01-01

    Following focal sensory adaptation, the perceived separation between visual stimuli that straddle the adapted region is often exaggerated. For instance, in the tilt aftereffect illusion, adaptation to tilted lines causes subsequently viewed lines with nearby orientations to be perceptually repelled from the adapted orientation. Repulsion illusions in the nonvisual senses have been less studied. Here, we investigated whether adaptation induces a repulsion illusion in tactile spatial perception. In a two-interval forced-choice task, participants compared the perceived separation between two point-stimuli applied on the forearms successively. Separation distance was constant on one arm (the reference) and varied on the other arm (the comparison). In Experiment 1, we took three consecutive baseline measurements, verifying that in the absence of manipulation, participants’ distance perception was unbiased across arms and stable across experimental blocks. In Experiment 2, we vibrated a region of skin on the reference arm, verifying that this focally reduced tactile sensitivity, as indicated by elevated monofilament detection thresholds. In Experiment 3, we applied vibration between the two reference points in our distance perception protocol and discovered that this caused an illusory increase in the separation between the points. We conclude that focal adaptation induces a repulsion aftereffect illusion in tactile spatial perception. The illusion provides clues as to how the tactile system represents spatial information. The analogous repulsion aftereffects caused by adaptation in different stimulus domains and sensory systems may point to fundamentally similar strategies for dynamic sensory coding. PMID:28701936

  10. On the Reality of Illusory Conjunctions.

    PubMed

    Botella, Juan; Suero, Manuel; Durán, Juan I

    2017-01-01

    The reality of illusory conjunctions in perception has been sometimes questioned, arguing that they can be explained by other mechanisms. Most relevant experiments are based on migrations along the space dimension. But the low rate of illusory conjunctions along space can easily hide them among other types of errors. As migrations over time are a more frequent phenomenon, illusory conjunctions can be disentangled from other errors. We report an experiment in which series of colored letters were presented in several spatial locations, allowing for migrations over both space and time. The distribution of frequencies were fit by several multinomial tree models based on alternative hypothesis about illusory conjunctions and the potential sources of free-floating features. The best-fit model acknowledges that most illusory conjunctions are migrations in the time domain. Migrations in space are probably present, but the rate is very low. Other conjunction errors, as those produced by guessing or miscategorizations of the to-be-reported feature, are also present in the experiment. The main conclusion is that illusory conjunctions do exist.

  11. Inducing any virtual two-dimensional movement in humans by applying muscle tendon vibration.

    PubMed

    Roll, Jean-Pierre; Albert, Frédéric; Thyrion, Chloé; Ribot-Ciscar, Edith; Bergenheim, Mikael; Mattei, Benjamin

    2009-02-01

    In humans, tendon vibration evokes illusory sensation of movement. We developed a model mimicking the muscle afferent patterns corresponding to any two-dimensional movement and checked its validity by inducing writing illusory movements through specific sets of muscle vibrators. Three kinds of illusory movements were compared. The first was induced by vibration patterns copying the responses of muscle spindle afferents previously recorded by microneurography during imposed ankle movements. The two others were generated by the model. Sixteen different vibratory patterns were applied to 20 motionless volunteers in the absence of vision. After each vibration sequence, the participants were asked to name the corresponding graphic symbol and then to reproduce the illusory movement perceived. Results showed that the afferent patterns generated by the model were very similar to those recorded microneurographically during actual ankle movements (r=0.82). The model was also very efficient for generating afferent response patterns at the wrist level, if the preferred sensory directions of the wrist muscle groups were first specified. Using recorded and modeled proprioceptive patterns to pilot sets of vibrators placed at the ankle or wrist levels evoked similar illusory movements, which were correctly identified by the participants in three quarters of the trials. Our proprioceptive model, based on neurosensory data recorded in behaving humans, should then be a useful tool in fields of research such as sensorimotor learning, rehabilitation, and virtual reality.

  12. Investigating the mechanisms of visually-evoked tactile sensations.

    PubMed

    McKenzie, Kirsten J; Lloyd, Donna M; Brown, Richard J; Plummer, Faye; Poliakoff, Ellen

    2012-01-01

    When attempting to detect a near-threshold signal, participants often incorrectly report the presence of a signal, particularly when a stimulus in a different modality is presented. Here we investigated the effect of prior experience of bimodal visuotactile stimuli on the rate of falsely reported touches in the presence of a light. In Experiment 1, participants made more false alarms in light-present than light-absent trials, despite having no experience of the experimental visuotactile pairing. This suggests that light-evoked false alarms are a consequence of an existing association, rather than one learned during the experiment. In Experiment 2, we sought to manipulate the strength of the association through prior training, using supra-threshold tactile stimuli that were given a high or low association with the light. Both groups still exhibited an increased number of false alarms during light-present trials, however, the low association group made significantly fewer false alarms across conditions, and there was no corresponding group difference in the number of tactile stimuli correctly identified. Thus, while training did not affect the boosting of the tactile signal by the visual stimulus, the low association training affected perceptual decision-making more generally, leading to a lower number of illusory touch reports, independent of the light. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Spatio-temporal processing of tactile stimuli in autistic children

    PubMed Central

    Wada, Makoto; Suzuki, Mayuko; Takaki, Akiko; Miyao, Masutomo; Spence, Charles; Kansaku, Kenji

    2014-01-01

    Altered multisensory integration has been reported in autism; however, little is known concerning how the autistic brain processes spatio-temporal information concerning tactile stimuli. We report a study in which a crossed-hands illusion was investigated in autistic children. Neurotypical individuals often experience a subjective reversal of temporal order judgments when their hands are stimulated while crossed, and the illusion is known to be acquired in early childhood. However, under those conditions where the somatotopic representation is given priority over the actual spatial location of the hands, such reversals may not occur. Here, we showed that a significantly smaller illusory reversal was demonstrated in autistic children than in neurotypical children. Furthermore, in an additional experiment, the young boys who had higher Autism Spectrum Quotient (AQ) scores generally showed a smaller crossed hands deficit. These results suggest that rudimentary spatio-temporal processing of tactile stimuli exists in autistic children, and the altered processing may interfere with the development of an external frame of reference in real-life situations. PMID:25100146

  14. Availability of vision and tactile gating: vision enhances tactile sensitivity.

    PubMed

    Colino, Francisco L; Lee, Ji-Hang; Binsted, Gordon

    2017-01-01

    A multitude of events bombard our sensory systems at every moment of our lives. Thus, it is important for the sensory and motor cortices to gate unimportant events. Tactile suppression is a well-known phenomenon defined as a reduced ability to detect tactile events on the skin before and during movement. Previous experiments (Buckingham et al. in Exp Brain Res 201(3):411-419, 2010; Colino et al. in Physiol Rep 2(3):e00267, 2014) found detection rates decrease just prior to and during finger abduction and decrease according to the proximity of the moving effector. However, what effect does vision have on tactile gating? There is ample evidence (see Serino and Haggard in Neurosci Biobehav Rev 34:224-236, 2010) observing increased tactile acuity when participants see their limbs. The present study examined how tactile detection changes in response to visual condition (vision/no vision). Ten human participants used their right hand to reach and grasp a cylinder. Tactors were attached to the index finger and the forearm of both the right and left arm and vibrated at various epochs relative to a "go" tone. Results replicate previous findings from our laboratory (Colino et al. in Physiol Rep 2(3):e00267, 2014). Also, tactile acuity decreased when participants did not have vision. These results indicate that the vision affects the somatosensation via inputs from parietal areas (Konen and Haggard in Cereb Cortex 24(2):501-507, 2014) but does so in a reach-to-grasp context.

  15. Tactile cues can change movement: An example using tape to redistribute flexion from the lumbar spine to the hips and knees during lifting.

    PubMed

    Pinto, Brendan L; Beaudette, Shawn M; Brown, Stephen H M

    2018-05-14

    Given the appropriate cues, kinematic factors associated with low back injury risk and pain, such as spine flexion, can be avoided. Recent research has demonstrated the potential for tactile sensory information to change movement. In this study an athletic strapping tape was applied bilaterally along the lumbar extensor muscles to provide continuous tactile feedback information during a repeated lifting and lowering task. The presence of the tape resulted in a statistically significant reduction in lumbar spine flexion when compared to a baseline condition in which no tape was present. This reduction was further increased with the explicit instruction to pay attention to the sensations elicited by the tape. In both cases, the reduction in lumbar spine flexion was compensated for by increases in hip and knee flexion. When the tape was then removed and participants were instructed to continue lifting as if it was still present, the reduction in lumbar flexion and increases in hip and knee flexion were retained. Thus this study provides evidence that tactile cues can provide vital feedback information that can cue human lumbar spine movement to reduce kinematic factors associated with injury risk and pain. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. The extrastriate body area is involved in illusory limb ownership.

    PubMed

    Limanowski, Jakub; Lutti, Antoine; Blankenburg, Felix

    2014-02-01

    The Rubber Hand Illusion (RHI) is an established paradigm for studying body ownership, and several studies have implicated premotor and temporo-parietal brain regions in its neuronal foundation. Here we used an automated setup to induce a novel multi-site version of the RHI in healthy human participants inside an MR-scanner, with a RHI and control condition that were matched in terms of synchrony of visual and tactile stimulation. Importantly, as previous research has shown that most of the ownership-related brain areas also respond to observed human actions and touch, or body parts of others, here such potential effects of the experimenter were eliminated by the automated procedure. The RHI condition induced a strong ownership illusion; we found correspondingly stronger brain activity during the RHI versus control condition in contralateral middle occipital gyrus (mOCG) and bilateral anterior insula, which have previously been related to illusory body ownership. Using independent functional localizers, we confirmed that the activity in mOCG was located within the body-part selective extrastriate body area (EBA). Crucially, activity differences in participants' peak voxels within the left EBA correlated strongly positively with their behavioral illusion scores. Thus EBA activity also reflected interindividual differences in the experienced intensity of illusory limb ownership. Moreover, psychophysiological interaction analyses (PPI) revealed that contralateral primary somatosensory cortex had stronger brain connectivity with EBA during the RHI versus control condition, while EBA was more strongly interacting with temporo-parietal multisensory regions. In sum, our findings demonstrate a direct involvement of EBA in limb ownership. © 2013 Elsevier Inc. All rights reserved.

  17. Mechanisms underlying a thalamocortical transformation during active tactile sensation

    PubMed Central

    Gutnisky, Diego Adrian; Yu, Jianing; Hires, Samuel Andrew; To, Minh-Son; Svoboda, Karel

    2017-01-01

    During active somatosensation, neural signals expected from movement of the sensors are suppressed in the cortex, whereas information related to touch is enhanced. This tactile suppression underlies low-noise encoding of relevant tactile features and the brain’s ability to make fine tactile discriminations. Layer (L) 4 excitatory neurons in the barrel cortex, the major target of the somatosensory thalamus (VPM), respond to touch, but have low spike rates and low sensitivity to the movement of whiskers. Most neurons in VPM respond to touch and also show an increase in spike rate with whisker movement. Therefore, signals related to self-movement are suppressed in L4. Fast-spiking (FS) interneurons in L4 show similar dynamics to VPM neurons. Stimulation of halorhodopsin in FS interneurons causes a reduction in FS neuron activity and an increase in L4 excitatory neuron activity. This decrease of activity of L4 FS neurons contradicts the "paradoxical effect" predicted in networks stabilized by inhibition and in strongly-coupled networks. To explain these observations, we constructed a model of the L4 circuit, with connectivity constrained by in vitro measurements. The model explores the various synaptic conductance strengths for which L4 FS neurons actively suppress baseline and movement-related activity in layer 4 excitatory neurons. Feedforward inhibition, in concert with recurrent intracortical circuitry, produces tactile suppression. Synaptic delays in feedforward inhibition allow transmission of temporally brief volleys of activity associated with touch. Our model provides a mechanistic explanation of a behavior-related computation implemented by the thalamocortical circuit. PMID:28591219

  18. The role of attention in illusory conjunctions.

    PubMed

    Tsal, Y; Meiran, N; Lavie, N

    1994-03-01

    In five experiments, we investigated the effects of attention on illusory conjunctions formed between features of unrelated objects. The first three experiments used a weak manipulation of attention and found that illusory conjunctions formed either among features receiving high attentional priority or among features receiving low attentional priority were not more frequent than were conjunctions formed between mixed features of different attentional priority. The last two experiments used a strong manipulation of attention and failed to reveal any evidence of true illusory conjunctions. The results are inconsistent with the feature-integration theory, which predicts that when attention is focused on a subset of items, illusory conjunctions ought to occur within and outside of the attended subset, but not between the attended and unattended items.

  19. Tactile suppression of displacement.

    PubMed

    Ziat, Mounia; Hayward, Vincent; Chapman, C Elaine; Ernst, Marc O; Lenay, Charles

    2010-10-01

    In vision, the discovery of the phenomenon of saccadic suppression of displacement has made important contributions to the understanding of the stable world problem. Here, we report a similar phenomenon in the tactile modality. When scanning a single Braille dot with two fingers of the same hand, participants were asked to decide whether the dot was stationary or whether it was displaced from one location to another. The stimulus was produced by refreshable Braille devices that have dots that can be swiftly raised and recessed. In some conditions, the dot was stationary. In others, a displacement was created by monitoring the participant's finger position and by switching the dot activation when it was not touched by either finger. The dot displacement was of either 2.5 mm or 5 mm. We found that in certain cases, displaced dots were felt to be stationary. If the displacement was orthogonal to the finger movements, tactile suppression occurred effectively when it was of 2.5 mm, but when the displacement was of 5 mm, the participants easily detected it. If the displacement was medial-lateral, the suppression effect occurred as well, but less often when the apparent movement of the dot opposed the movement of the finger. In such cases, the stimulus appeared sooner than when the brain could predict it from finger movement, supporting a predictive rather than a postdictive differential processing hypothesis.

  20. Thinking about touch facilitates tactile but not auditory processing.

    PubMed

    Anema, Helen A; de Haan, Alyanne M; Gebuis, Titia; Dijkerman, H Chris

    2012-05-01

    Mental imagery is considered to be important for normal conscious experience. It is most frequently investigated in the visual, auditory and motor domain (imagination of movement), while the studies on tactile imagery (imagination of touch) are scarce. The current study investigated the effect of tactile and auditory imagery on the left/right discriminations of tactile and auditory stimuli. In line with our hypothesis, we observed that after tactile imagery, tactile stimuli were responded to faster as compared to auditory stimuli and vice versa. On average, tactile stimuli were responded to faster as compared to auditory stimuli, and stimuli in the imagery condition were on average responded to slower as compared to baseline performance (left/right discrimination without imagery assignment). The former is probably due to the spatial and somatotopic proximity of the fingers receiving the taps and the thumbs performing the response (button press), the latter to a dual task cost. Together, these results provide the first evidence of a behavioural effect of a tactile imagery assignment on the perception of real tactile stimuli.

  1. Decoding illusory self-location from activity in the human hippocampus.

    PubMed

    Guterstam, Arvid; Björnsdotter, Malin; Bergouignan, Loretxu; Gentile, Giovanni; Li, Tie-Qiang; Ehrsson, H Henrik

    2015-01-01

    Decades of research have demonstrated a role for the hippocampus in spatial navigation and episodic and spatial memory. However, empirical evidence linking hippocampal activity to the perceptual experience of being physically located at a particular place in the environment is lacking. In this study, we used a multisensory out-of-body illusion to perceptually 'teleport' six healthy participants between two different locations in the scanner room during high-resolution functional magnetic resonance imaging (fMRI). The participants were fitted with MRI-compatible head-mounted displays that changed their first-person visual perspective to that of a pair of cameras placed in one of two corners of the scanner room. To elicit the illusion of being physically located in this position, we delivered synchronous visuo-tactile stimulation in the form of an object moving toward the cameras coupled with touches applied to the participant's chest. Asynchronous visuo-tactile stimulation did not induce the illusion and served as a control condition. We found that illusory self-location could be successfully decoded from patterns of activity in the hippocampus in all of the participants in the synchronous (P < 0.05) but not in the asynchronous condition (P > 0.05). At the group-level, the decoding accuracy was significantly higher in the synchronous than in the asynchronous condition (P = 0.012). These findings associate hippocampal activity with the perceived location of the bodily self in space, which suggests that the human hippocampus is involved not only in spatial navigation and memory but also in the construction of our sense of bodily self-location.

  2. Decoding illusory self-location from activity in the human hippocampus

    PubMed Central

    Guterstam, Arvid; Björnsdotter, Malin; Bergouignan, Loretxu; Gentile, Giovanni; Li, Tie-Qiang; Ehrsson, H. Henrik

    2015-01-01

    Decades of research have demonstrated a role for the hippocampus in spatial navigation and episodic and spatial memory. However, empirical evidence linking hippocampal activity to the perceptual experience of being physically located at a particular place in the environment is lacking. In this study, we used a multisensory out-of-body illusion to perceptually ‘teleport’ six healthy participants between two different locations in the scanner room during high-resolution functional magnetic resonance imaging (fMRI). The participants were fitted with MRI-compatible head-mounted displays that changed their first-person visual perspective to that of a pair of cameras placed in one of two corners of the scanner room. To elicit the illusion of being physically located in this position, we delivered synchronous visuo-tactile stimulation in the form of an object moving toward the cameras coupled with touches applied to the participant’s chest. Asynchronous visuo-tactile stimulation did not induce the illusion and served as a control condition. We found that illusory self-location could be successfully decoded from patterns of activity in the hippocampus in all of the participants in the synchronous (P < 0.05) but not in the asynchronous condition (P > 0.05). At the group-level, the decoding accuracy was significantly higher in the synchronous than in the asynchronous condition (P = 0.012). These findings associate hippocampal activity with the perceived location of the bodily self in space, which suggests that the human hippocampus is involved not only in spatial navigation and memory but also in the construction of our sense of bodily self-location. PMID:26236222

  3. How Does Brain Activation Differ in Children with Unilateral Cerebral Palsy Compared to Typically Developing Children, during Active and Passive Movements, and Tactile Stimulation? An fMRI Study

    ERIC Educational Resources Information Center

    Van de Winckel, Ann; Klingels, Katrijn; Bruyninckx, Frans; Wenderoth, Nici; Peeters, Ron; Sunaert, Stefan; Van Hecke, Wim; De Cock, Paul; Eyssen, Maria; De Weerdt, Willy; Feys, Hilde

    2013-01-01

    The aim of the functional magnetic resonance imaging (fMRI) study was to investigate brain activation associated with active and passive movements, and tactile stimulation in 17 children with right-sided unilateral cerebral palsy (CP), compared to 19 typically developing children (TD). The active movements consisted of repetitive opening and…

  4. Mitigating Illusory Results through Preregistration in Education

    ERIC Educational Resources Information Center

    Gehlbach, Hunter; Robinson, Carly D.

    2018-01-01

    Like performance-enhancing drugs inflating apparent athletic achievements, several common social science practices contribute to the production of illusory results. In this article, we examine the processes that lead to illusory findings and describe their consequences. We borrow from an approach used increasingly by other disciplines--the norm of…

  5. How visual illusions illuminate complementary brain processes: illusory depth from brightness and apparent motion of illusory contours

    PubMed Central

    Grossberg, Stephen

    2014-01-01

    Neural models of perception clarify how visual illusions arise from adaptive neural processes. Illusions also provide important insights into how adaptive neural processes work. This article focuses on two illusions that illustrate a fundamental property of global brain organization; namely, that advanced brains are organized into parallel cortical processing streams with computationally complementary properties. That is, in order to process certain combinations of properties, each cortical stream cannot process complementary properties. Interactions between these streams, across multiple processing stages, overcome their complementary deficiencies to compute effective representations of the world, and to thereby achieve the property of complementary consistency. The two illusions concern how illusory depth can vary with brightness, and how apparent motion of illusory contours can occur. Illusory depth from brightness arises from the complementary properties of boundary and surface processes, notably boundary completion and surface-filling in, within the parvocellular form processing cortical stream. This illusion depends upon how surface contour signals from the V2 thin stripes to the V2 interstripes ensure complementary consistency of a unified boundary/surface percept. Apparent motion of illusory contours arises from the complementary properties of form and motion processes across the parvocellular and magnocellular cortical processing streams. This illusion depends upon how illusory contours help to complete boundary representations for object recognition, how apparent motion signals can help to form continuous trajectories for target tracking and prediction, and how formotion interactions from V2-to-MT enable completed object representations to be continuously tracked even when they move behind intermittently occluding objects through time. PMID:25389399

  6. Tactile Data Entry System

    NASA Technical Reports Server (NTRS)

    Adams, Richard J.

    2015-01-01

    The patent-pending Glove-Enabled Computer Operations (GECO) design leverages extravehicular activity (EVA) glove design features as platforms for instrumentation and tactile feedback, enabling the gloves to function as human-computer interface devices. Flexible sensors in each finger enable control inputs that can be mapped to any number of functions (e.g., a mouse click, a keyboard strike, or a button press). Tracking of hand motion is interpreted alternatively as movement of a mouse (change in cursor position on a graphical user interface) or a change in hand position on a virtual keyboard. Programmable vibro-tactile actuators aligned with each finger enrich the interface by creating the haptic sensations associated with control inputs, such as recoil of a button press.

  7. Vibratory tactile display for textures

    NASA Technical Reports Server (NTRS)

    Ikei, Yasushi; Ikeno, Akihisa; Fukuda, Shuichi

    1994-01-01

    We have developed a tactile display that produces vibratory stimulus to a fingertip in contact with a vibrating tactor matrix. The display depicts tactile surface textures while the user is exploring a virtual object surface. A piezoelectric actuator drives the individual tactor in accordance with both the finger movement and the surface texture being traced. Spatiotemporal display control schemes were examined for presenting the fundamental surface texture elements. The temporal duration of vibratory stimulus was experimentally optimized to simulate the adaptation process of cutaneous sensation. The selected duration time for presenting a single line edge agreed with the time threshold of tactile sensation. Then spatial stimulus disposition schemes were discussed for representation of other edge shapes. As an alternative means not relying on amplitude control, a method of augmented duration at the edge was investigated. Spatial resolution of the display was measured for the lines presented both in perpendicular and parallel to a finger axis. Discrimination of texture density was also measured on random dot textures.

  8. If it's not there, where is it? Locating illusory conjunctions.

    PubMed

    Hazeltine, R E; Prinzmetal, W; Elliott, W

    1997-02-01

    There is evidence that complex objects are decomposed by the visual system into features, such as shape and color. Consistent with this theory is the phenomenon of illusory conjunctions, which occur when features are incorrectly combined to form an illusory object. We analyzed the perceived location of illusory conjunctions to study the roles of color and shape in the location of visual objects. In Experiments 1 and 2, participants located illusory conjunctions about halfway between the veridical locations of the component features. Experiment 3 showed that the distribution of perceived locations was not the mixture of two distributions centered at the 2 feature locations. Experiment 4 replicated these results with an identification task rather than a detection task. We concluded that the locations of illusory conjunctions were not arbitrary but were determined by both constituent shape and color.

  9. Illusory body-ownership entails automatic compensative movement: for the unified representation between body and action.

    PubMed

    Asai, Tomohisa

    2015-03-01

    The sense of body-ownership involves the integration of vision and somatosensation. In the rubber hand illusion (RHI), watching a rubber hand being stroked for a short time synchronously as one's own unseen hand is also stroked causes the observers to attribute the rubber hand to their own body. The RHI may elicit proprioceptive drift: The observers' sense of their own hand's location drifts toward the external proxy hand. The current experiments examined the possibility of observing, not the proprioceptive drift, but the actual drift "movement" during RHI induction. The participants' hand, located on horizontally movable board, tended to move toward the rubber hand only while they observed synchronous visuo-tactile stimulation. Furthermore, even when the participants' hand was located on a fixed, unmovable board (that is, the conventional RHI paradigm), participants automatically administered the force toward the rubber hand. These findings suggest that since awareness of our own body and action are fundamental to self-consciousness, these components of "minimal self" are closely related and integrated into "one agent" with a unified awareness of the body and action.

  10. Perception of Fechner Illusory Colors in Alzheimer Disease Patients

    PubMed Central

    Kaubrys, Gintaras; Bukina, Vera; Bingelytė, Ieva; Taluntis, Vladas

    2016-01-01

    Background Alzheimer disease (AD) primarily affects cognition. A variety of visual disorders was established in AD. Fechner illusory colors are produced by a rotating disk with a black and white pattern. The purpose of our research was to explore the perception of illusory colors in AD. Material/Methods W recruited 40 AD patients (MMSE ≥14) and 40 normal controls (CG group) matched by age, education, gender in this prospective, cross-sectional, case-control study. An achromatic Benham’s disk attached to a device to control the speed and direction of rotation was used to produce illusory colors. Primary, secondary, and tertiary RGB system colors were used for matching of illusory and physical colors. Results Subjects in the AD group perceived less illusory colors in 5 arcs (p<0.05) of the 8 arcs assessed. The biggest difference was found between AD and CG groups for pure blue (χ2=26.87, p<0.001 clockwise, χ2=22.75, p<0.001 counter-clockwise). Groups did not differ in perception of pure yellow opponent colors (p>0.05). Mixed colors of the blue-yellow axis were perceived less often in AD, but more frequently than pure blue (#0000FF). The sequence of colors on Benham’s disk followed a complex pattern, different from the order of physical spectral colors and opponent processes-based colors. Conclusions AD patients retained reduced perception of illusory colors. The perception of pure blue illusory color is almost absent in AD. The asymmetrical shift to the yellow opponent is observed in AD with red prevailing over green constituent. This may indicate cortical rather than retinal impairment. PMID:27902677

  11. Perception of Fechner Illusory Colors in Alzheimer Disease Patients.

    PubMed

    Kaubrys, Gintaras; Bukina, Vera; Bingelytė, Ieva; Taluntis, Vladas

    2016-11-30

    BACKGROUND Alzheimer disease (AD) primarily affects cognition. A variety of visual disorders was established in AD. Fechner illusory colors are produced by a rotating disk with a black and white pattern. The purpose of our research was to explore the perception of illusory colors in AD. MATERIAL AND METHODS W recruited 40 AD patients (MMSE ≥14) and 40 normal controls (CG group) matched by age, education, gender in this prospective, cross-sectional, case-control study. An achromatic Benham's disk attached to a device to control the speed and direction of rotation was used to produce illusory colors. Primary, secondary, and tertiary RGB system colors were used for matching of illusory and physical colors. RESULTS Subjects in the AD group perceived less illusory colors in 5 arcs (p<0.05) of the 8 arcs assessed. The biggest difference was found between AD and CG groups for pure blue (χ²=26.87, p<0.001 clockwise, χ²=22.75, p<0.001 counter-clockwise). Groups did not differ in perception of pure yellow opponent colors (p>0.05). Mixed colors of the blue-yellow axis were perceived less often in AD, but more frequently than pure blue (#0000FF). The sequence of colors on Benham's disk followed a complex pattern, different from the order of physical spectral colors and opponent processes-based colors. CONCLUSIONS AD patients retained reduced perception of illusory colors. The perception of pure blue illusory color is almost absent in AD. The asymmetrical shift to the yellow opponent is observed in AD with red prevailing over green constituent. This may indicate cortical rather than retinal impairment.

  12. Is meaning implicated in illusory conjunctions?

    PubMed

    Virzi, R A; Egeth, H E

    1984-08-01

    According to feature-integration theory, when attention is diverted from a display, features from different objects in that display may be wrongly recombined, giving rise to "illusory conjunctions" (Treisman & Schmidt, 1982). Two experiments are reported that examine the nature of these illusory conjunctions. In displays that contain color names and adjectives printed in colored ink, subjects made two kinds of interesting and previously unreported errors. Consider, for example, a display that included the word BROWN in red ink and the word HEAVY in green ink. Subjects would sometimes incorrectly report that the word RED or the ink color brown had appeared in the display (e.g., RED in green ink or HEAVY in brown ink). It appears that subjects extract semantic representations from input and are sometimes confused about whether a particular representation has been extracted from a word or a color patch. Contrary to feature-integration theory, these findings suggest that illusory conjunctions may occur with high-level codes as well as with perceptual features.

  13. Directional bias of illusory stream caused by relative motion adaptation.

    PubMed

    Tomimatsu, Erika; Ito, Hiroyuki

    2016-07-01

    Enigma is an op-art painting that elicits an illusion of rotational streaming motion. In the present study, we tested whether adaptation to various motion configurations that included relative motion components could be reflected in the directional bias of the illusory stream. First, participants viewed the center of a rotating Enigma stimulus for adaptation. There was no physical motion on the ring area. During the adaptation period, the illusory stream on the ring was mainly seen in the direction opposite to that of the physical rotation. After the physical rotation stopped, the illusory stream on the ring was mainly seen in the same direction as that of the preceding physical rotation. Moreover, adapting to strong relative motion induced a strong bias in the illusory motion direction in the subsequently presented static Enigma stimulus. The results suggest that relative motion detectors corresponding to the ring area may produce the illusory stream of Enigma. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Illusory visual motion stimulus elicits postural sway in migraine patients

    PubMed Central

    Imaizumi, Shu; Honma, Motoyasu; Hibino, Haruo; Koyama, Shinichi

    2015-01-01

    Although the perception of visual motion modulates postural control, it is unknown whether illusory visual motion elicits postural sway. The present study examined the effect of illusory motion on postural sway in patients with migraine, who tend to be sensitive to it. We measured postural sway for both migraine patients and controls while they viewed static visual stimuli with and without illusory motion. The participants’ postural sway was measured when they closed their eyes either immediately after (Experiment 1), or 30 s after (Experiment 2), viewing the stimuli. The patients swayed more than the controls when they closed their eyes immediately after viewing the illusory motion (Experiment 1), and they swayed less than the controls when they closed their eyes 30 s after viewing it (Experiment 2). These results suggest that static visual stimuli with illusory motion can induce postural sway that may last for at least 30 s in patients with migraine. PMID:25972832

  15. Let me take the wheel: Illusory control and sense of agency

    PubMed Central

    Tobias-Webb, Juliette; Limbrick-Oldfield, Eve H.; Gillan, Claire M.; Moore, James W.; Aitken, Michael R. F.; Clark, Luke

    2017-01-01

    ABSTRACT Illusory control refers to an effect in games of chance where features associated with skilful situations increase expectancies of success. Past work has operationalized illusory control in terms of subjective ratings or behaviour, with limited consideration of the relationship between these definitions, or the broader construct of agency. This study used a novel card-guessing task in 78 participants to investigate the relationship between subjective and behavioural illusory control. We compared trials in which participants (a) had no opportunity to exercise illusory control, (b) could exercise illusory control for free, or (c) could pay to exercise illusory control. Contingency Judgment and Intentional Binding tasks assessed explicit and implicit sense of agency, respectively. On the card-guessing task, confidence was higher when participants exerted control than in the baseline condition. In a complementary model, participants were more likely to exercise control when their confidence was high, and this effect was accentuated in the pay condition relative to the free condition. Decisions to pay were positively correlated with control ratings on the Contingency Judgment task, but were not significantly related to Intentional Binding. These results establish an association between subjective and behavioural illusory control and locate the construct within the cognitive literature on agency. PMID:27376771

  16. Tactile responses in the granule cell layer of cerebellar folium crus IIa of freely behaving rats

    NASA Technical Reports Server (NTRS)

    Hartmann, M. J.; Bower, J. M.

    2001-01-01

    We recorded activity from the granule cell layer (GCL) of cerebellar folium Crus IIa as freely moving rats engaged in a variety of natural behaviors, including grooming, eating, and free tactile exploration. Multiunit responses in the 1000-4500 Hz range were found to be strongly correlated with tactile stimulation of lip and whisker (perioral) regions. These responses occurred regardless of whether the stimulus was externally or self-generated and during both active and passive touch. In contrast, perioral movements that did not tactually stimulate this region of the face (e.g., chewing) produced no detectable increases in GCL activity. In addition, GCL responses were not correlated with movement extremes. When rats used their lips actively for palpation and exploration, the tactile responses in the GCL were not detectably modulated by ongoing jaw movements. However, active palpation and exploratory behaviors did result in the largest and most continuous bursts of GCL activity: responses were on average 10% larger and 50% longer during palpation and exploration than during grooming or passive stimulation. Although activity levels differed between behaviors, the position and spatial extent of the peripheral receptive field was similar over all behaviors that resulted in tactile input. Overall, our data suggest that the 1000-4500 Hz multiunit responses in the Crus IIa GCL of awake rats are correlated with tactile input rather than with movement or any movement parameter and that these responses are likely to be of particular importance during the acquisition of sensory information by perioral structures.

  17. The moral foundations of illusory correlation

    PubMed Central

    Barberia, Itxaso

    2017-01-01

    Previous research has studied the relationship between political ideology and cognitive biases, such as the tendency of conservatives to form stronger illusory correlations between negative infrequent behaviors and minority groups. We further explored these findings by studying the relation between illusory correlation and moral values. According to the moral foundations theory, liberals and conservatives differ in the relevance they concede to different moral dimensions: Care, Fairness, Loyalty, Authority, and Purity. Whereas liberals consistently endorse the Care and Fairness foundations more than the Loyalty, Authority and Purity foundations, conservatives tend to adhere to the five foundations alike. In the present study, a group of participants took part in a standard illusory correlation task in which they were presented with randomly ordered descriptions of either desirable or undesirable behaviors attributed to individuals belonging to numerically different majority and minority groups. Although the proportion of desirable and undesirable behaviors was the same in the two groups, participants attributed a higher frequency of undesirable behaviors to the minority group, thus showing the expected illusory correlation effect. Moreover, this effect was specifically associated to our participants’ scores in the Loyalty subscale of the Moral Foundations Questionnaire. These results emphasize the role of the Loyalty moral foundation in the formation of attitudes towards minorities among conservatives. Our study points out the moral system as a useful fine-grained framework to explore the complex interaction between basic cognitive processes and ideology. PMID:28972990

  18. Reach Trajectories Characterize Tactile Localization for Sensorimotor Decision Making.

    PubMed

    Brandes, Janina; Heed, Tobias

    2015-10-07

    Spatial target information for movement planning appears to be coded in a gaze-centered reference frame. In touch, however, location is initially coded with reference to the skin. Therefore, the tactile spatial location must be derived by integrating skin location and posture. It has been suggested that this recoding is impaired when the limb is placed in the opposite hemispace, for example, by limb crossing. Here, human participants reached toward visual and tactile targets located at uncrossed and crossed feet in a sensorimotor decision task. We characterized stimulus recoding by analyzing the timing and spatial profile of hand reaches. For tactile targets at crossed feet, skin-based information implicates the incorrect side, and only recoded information points to the correct location. Participants initiated straight reaches and redirected the hand toward a target presented in midflight. Trajectories to visual targets were unaffected by foot crossing. In contrast, trajectories to tactile targets were redirected later with crossed than uncrossed feet. Reaches to crossed feet usually continued straight until they were directed toward the correct tactile target and were not biased toward the skin-based target location. Occasional, far deflections toward the incorrect target were most likely when this target was implicated by trial history. These results are inconsistent with the suggestion that spatial transformations in touch are impaired by limb crossing, but are consistent with tactile location being recoded rapidly and efficiently, followed by integration of skin-based and external information to specify the reach target. This process may be implemented in a bounded integrator framework. How do you touch yourself, for instance, to scratch an itch? The place you need to reach is defined by a sensation on the skin, but our bodies are flexible, so this skin location could be anywhere in 3D space. The movement toward the tactile sensation must therefore be specified

  19. Blindness to Curvature and Blindness to Illusory Curvature.

    PubMed

    Bertamini, Marco; Kitaoka, Akiyoshi

    2018-01-01

    We compare two versions of two known phenomena, the Curvature blindness and the Kite mesh illusions, to highlight how similar manipulations lead to blindness to curvature and blindness to illusory curvature, respectively. The critical factor is a change in luminance polarity; this factor interferes with the computation of curvature along the contour, for both real and illusory curvature.

  20. Behavioral Impact of Unisensory and Multisensory Audio-Tactile Events: Pros and Cons for Interlimb Coordination in Juggling

    PubMed Central

    Zelic, Gregory; Mottet, Denis; Lagarde, Julien

    2012-01-01

    Recent behavioral neuroscience research revealed that elementary reactive behavior can be improved in the case of cross-modal sensory interactions thanks to underlying multisensory integration mechanisms. Can this benefit be generalized to an ongoing coordination of movements under severe physical constraints? We choose a juggling task to examine this question. A central issue well-known in juggling lies in establishing and maintaining a specific temporal coordination among balls, hands, eyes and posture. Here, we tested whether providing additional timing information about the balls and hands motions by using external sound and tactile periodic stimulations, the later presented at the wrists, improved the behavior of jugglers. One specific combination of auditory and tactile metronome led to a decrease of the spatiotemporal variability of the juggler's performance: a simple sound associated to left and right tactile cues presented antiphase to each other, which corresponded to the temporal pattern of hands movement in the juggling task. A contrario, no improvements were obtained in the case of other auditory and tactile combinations. We even found a degraded performance when tactile events were presented alone. The nervous system thus appears able to integrate in efficient way environmental information brought by different sensory modalities, but only if the information specified matches specific features of the coordination pattern. We discuss the possible implications of these results for the understanding of the neuronal integration process implied in audio-tactile interaction in the context of complex voluntary movement, and considering the well-known gating effect of movement on vibrotactile perception. PMID:22384211

  1. Tactile-STAR: A Novel Tactile STimulator And Recorder System for Evaluating and Improving Tactile Perception.

    PubMed

    Ballardini, Giulia; Carlini, Giorgio; Giannoni, Psiche; Scheidt, Robert A; Nisky, Ilana; Casadio, Maura

    2018-01-01

    Many neurological diseases impair the motor and somatosensory systems. While several different technologies are used in clinical practice to assess and improve motor functions, somatosensation is evaluated subjectively with qualitative clinical scales. Treatment of somatosensory deficits has received limited attention. To bridge the gap between the assessment and training of motor vs. somatosensory abilities, we designed, developed, and tested a novel, low-cost, two-component (bimanual) mechatronic system targeting tactile somatosensation: the Tactile-STAR -a tactile stimulator and recorder. The stimulator is an actuated pantograph structure driven by two servomotors, with an end-effector covered by a rubber material that can apply two different types of skin stimulation: brush and stretch. The stimulator has a modular design, and can be used to test the tactile perception in different parts of the body such as the hand, arm, leg, big toe, etc. The recorder is a passive pantograph that can measure hand motion using two potentiometers. The recorder can serve multiple purposes: participants can move its handle to match the direction and amplitude of the tactile stimulator, or they can use it as a master manipulator to control the tactile stimulator as a slave. Our ultimate goal is to assess and affect tactile acuity and somatosensory deficits. To demonstrate the feasibility of our novel system, we tested the Tactile-STAR with 16 healthy individuals and with three stroke survivors using the skin-brush stimulation. We verified that the system enables the mapping of tactile perception on the hand in both populations. We also tested the extent to which 30 min of training in healthy individuals led to an improvement of tactile perception. The results provide a first demonstration of the ability of this new system to characterize tactile perception in healthy individuals, as well as a quantification of the magnitude and pattern of tactile impairment in a small cohort of

  2. Active tactile sampling by an insect in a step-climbing paradigm

    PubMed Central

    Krause, André F.; Dürr, Volker

    2012-01-01

    Many insects actively explore their near-range environment with their antennae. Stick insects (Carausius morosus) rhythmically move their antennae during walking and respond to antennal touch by repetitive tactile sampling of the object. Despite its relevance for spatial orientation, neither the spatial sampling patterns nor the kinematics of antennation behavior in insects are understood. Here we investigate unrestrained bilateral sampling movements during climbing of steps. The main objectives are: (1) How does the antennal contact pattern relate to particular object features? (2) How are the antennal joints coordinated during bilateral tactile sampling? We conducted motion capture experiments on freely climbing insects, using steps of different height. Tactile sampling was analyzed at the level of antennal joint angles. Moreover, we analyzed contact patterns on the surfaces of both the obstacle and the antenna itself. Before the first contact, both antennae move in a broad, mostly elliptical exploratory pattern. After touching the obstacle, the pattern switches to a narrower and faster movement, caused by higher cycle frequencies and lower cycle amplitudes in all joints. Contact events were divided into wall- and edge-contacts. Wall contacts occurred mostly with the distal third of the flagellum, which is flexible, whereas edge contacts often occurred proximally, where the flagellum is stiff. The movement of both antennae was found to be coordinated, exhibiting bilateral coupling of functionally analogous joints [e.g., left head-scape (HS) joint with right scape-pedicel (SP) joint] throughout tactile sampling. In comparison, bilateral coupling between homologous joints (e.g., both HS joints) was significantly weaker. Moreover, inter-joint coupling was significantly weaker during the contact episode than before. In summary, stick insects show contact-induced changes in frequency, amplitude and inter-joint coordination during tactile sampling of climbed obstacles

  3. Interocular induction of illusory size perception

    PubMed Central

    2011-01-01

    Background The perceived size of objects not only depends on their physical size but also on the surroundings in which they appear. For example, an object surrounded by small items looks larger than a physically identical object surrounded by big items (Ebbinghaus illusion), and a physically identical but distant object looks larger than an object that appears closer in space (Ponzo illusion). Activity in human primary visual cortex (V1) reflects the perceived rather than the physical size of objects, indicating an involvement of V1 in illusory size perception. Here we investigate the role of eye-specific signals in two common size illusions in order to provide further information about the mechanisms underlying illusory size perception. Results We devised stimuli so that an object and its spatial context associated with illusory size perception could be presented together to one eye or separately to two eyes. We found that the Ponzo illusion had an equivalent magnitude whether the objects and contexts were presented to the same or different eyes, indicating that it may be largely mediated by binocular neurons. In contrast, the Ebbinghaus illusion became much weaker when objects and their contexts were presented to different eyes, indicating important contributions to the illusion from monocular neurons early in the visual pathway. Conclusions Our findings show that two well-known size illusions - the Ponzo illusion and the Ebbinghaus illusion - are mediated by different neuronal populations, and suggest that the underlying neural mechanisms associated with illusory size perception differ and can be dependent on monocular channels in the early visual pathway. PMID:21396093

  4. Interocular induction of illusory size perception.

    PubMed

    Song, Chen; Schwarzkopf, D Samuel; Rees, Geraint

    2011-03-11

    The perceived size of objects not only depends on their physical size but also on the surroundings in which they appear. For example, an object surrounded by small items looks larger than a physically identical object surrounded by big items (Ebbinghaus illusion), and a physically identical but distant object looks larger than an object that appears closer in space (Ponzo illusion). Activity in human primary visual cortex (V1) reflects the perceived rather than the physical size of objects, indicating an involvement of V1 in illusory size perception. Here we investigate the role of eye-specific signals in two common size illusions in order to provide further information about the mechanisms underlying illusory size perception. We devised stimuli so that an object and its spatial context associated with illusory size perception could be presented together to one eye or separately to two eyes. We found that the Ponzo illusion had an equivalent magnitude whether the objects and contexts were presented to the same or different eyes, indicating that it may be largely mediated by binocular neurons. In contrast, the Ebbinghaus illusion became much weaker when objects and their contexts were presented to different eyes, indicating important contributions to the illusion from monocular neurons early in the visual pathway. Our findings show that two well-known size illusions - the Ponzo illusion and the Ebbinghaus illusion - are mediated by different neuronal populations, and suggest that the underlying neural mechanisms associated with illusory size perception differ and can be dependent on monocular channels in the early visual pathway.

  5. To what extent do Gestalt grouping principles influence tactile perception?

    PubMed

    Gallace, Alberto; Spence, Charles

    2011-07-01

    Since their formulation by the Gestalt movement more than a century ago, the principles of perceptual grouping have primarily been investigated in the visual modality and, to a lesser extent, in the auditory modality. The present review addresses the question of whether the same grouping principles also affect the perception of tactile stimuli. Although, to date, only a few studies have explicitly investigated the existence of Gestalt grouping principles in the tactile modality, we argue that many more studies have indirectly provided evidence relevant to this topic. Reviewing this body of research, we argue that similar principles to those reported previously in visual and auditory studies also govern the perceptual grouping of tactile stimuli. In particular, we highlight evidence showing that the principles of proximity, similarity, common fate, good continuation, and closure affect tactile perception in both unimodal and crossmodal settings. We also highlight that the grouping of tactile stimuli is often affected by visual and auditory information that happen to be presented simultaneously. Finally, we discuss the theoretical and applied benefits that might pertain to the further study of Gestalt principles operating in both unisensory and multisensory tactile perception.

  6. Kinesthetic information facilitates saccades towards proprioceptive-tactile targets.

    PubMed

    Voudouris, Dimitris; Goettker, Alexander; Mueller, Stefanie; Fiehler, Katja

    2016-05-01

    Saccades to somatosensory targets have longer latencies and are less accurate and precise than saccades to visual targets. Here we examined how different somatosensory information influences the planning and control of saccadic eye movements. Participants fixated a central cross and initiated a saccade as fast as possible in response to a tactile stimulus that was presented to either the index or the middle fingertip of their unseen left hand. In a static condition, the hand remained at a target location for the entire block of trials and the stimulus was presented at a fixed time after an auditory tone. Therefore, the target location was derived only from proprioceptive and tactile information. In a moving condition, the hand was first actively moved to the same target location and the stimulus was then presented immediately. Thus, in the moving condition additional kinesthetic information about the target location was available. We found shorter saccade latencies in the moving compared to the static condition, but no differences in accuracy or precision of saccadic endpoints. In a second experiment, we introduced variable delays after the auditory tone (static condition) or after the end of the hand movement (moving condition) in order to reduce the predictability of the moment of the stimulation and to allow more time to process the kinesthetic information. Again, we found shorter latencies in the moving compared to the static condition but no improvement in saccade accuracy or precision. In a third experiment, we showed that the shorter saccade latencies in the moving condition cannot be explained by the temporal proximity between the relevant event (auditory tone or end of hand movement) and the moment of the stimulation. Our findings suggest that kinesthetic information facilitates planning, but not control, of saccadic eye movements to proprioceptive-tactile targets. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Paranormal believers are more prone to illusory agency detection than skeptics.

    PubMed

    van Elk, Michiel

    2013-09-01

    It has been hypothesized that illusory agency detection is at the basis of belief in supernatural agents and paranormal beliefs. In the present study a biological motion perception task was used to study illusory agency detection in a group of skeptics and a group of paranormal believers. Participants were required to detect the presence or absence of a human agent in a point-light display. It was found that paranormal believers had a lower perceptual sensitivity than skeptics, which was due to a response bias to 'yes' for stimuli in which no agent was present. The relation between paranormal beliefs and illusory agency detection held only for stimuli with low to intermediate ambiguity, but for stimuli with a high number of visual distractors responses of believers and skeptics were at the same level. Furthermore, it was found that illusory agency detection was unrelated to traditional religious belief and belief in witchcraft, whereas paranormal beliefs (i.e. Psi, spiritualism, precognition, superstition) were strongly related to illusory agency detection. These findings qualify the relation between illusory pattern perception and supernatural and paranormal beliefs and suggest that paranormal beliefs are strongly related to agency detection biases. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Natural Whisker-Guided Behavior by Head-Fixed Mice in Tactile Virtual Reality

    PubMed Central

    Sofroniew, Nicholas J.; Cohen, Jeremy D.; Lee, Albert K.

    2014-01-01

    During many natural behaviors the relevant sensory stimuli and motor outputs are difficult to quantify. Furthermore, the high dimensionality of the space of possible stimuli and movements compounds the problem of experimental control. Head fixation facilitates stimulus control and movement tracking, and can be combined with techniques for recording and manipulating neural activity. However, head-fixed mouse behaviors are typically trained through extensive instrumental conditioning. Here we present a whisker-based, tactile virtual reality system for head-fixed mice running on a spherical treadmill. Head-fixed mice displayed natural movements, including running and rhythmic whisking at 16 Hz. Whisking was centered on a set point that changed in concert with running so that more protracted whisking was correlated with faster running. During turning, whiskers moved in an asymmetric manner, with more retracted whisker positions in the turn direction and protracted whisker movements on the other side. Under some conditions, whisker movements were phase-coupled to strides. We simulated a virtual reality tactile corridor, consisting of two moveable walls controlled in a closed-loop by running speed and direction. Mice used their whiskers to track the walls of the winding corridor without training. Whisker curvature changes, which cause forces in the sensory follicles at the base of the whiskers, were tightly coupled to distance from the walls. Our behavioral system allows for precise control of sensorimotor variables during natural tactile navigation. PMID:25031397

  9. Illusory conjunctions die hard: a reply to Prinzmetal, Diedrichsen, and Ivry (2001).

    PubMed

    Donk, M

    2001-06-01

    M. Donk (1999) showed that various data patterns that have been considered as evidence for the existence of illusory conjunctions may be due to errors of target-nontarget confusion, an account that challenges the mere existence of illusory conjunction. In a reply, W. Prinzmetal, J. Diedrichsen, and R. B. Ivry (2001) argued against this conclusion, claiming that some earlier findings can be explained only when one assumes that illusory conjunctions exist. The current article shows that Prinzmetal et al.'s claims cannot refute any of Donk's earlier conclusions, suggesting indeed that one can only conclude that "illusory conjunctions are an illusion."

  10. Tactile discrimination, but not tactile stimulation alone, reduces chronic limb pain.

    PubMed

    Moseley, G Lorimer; Zalucki, Nadia M; Wiech, Katja

    2008-07-31

    Chronic pain is often associated with reduced tactile acuity. A relationship exists between pain intensity, tactile acuity and cortical reorganisation. When pain resolves, tactile function improves and cortical organisation normalises. Tactile acuity can be improved in healthy controls when tactile stimulation is associated with a behavioural objective. We hypothesised that, in patients with chronic limb pain and decreased tactile acuity, discriminating between tactile stimuli would decrease pain and increase tactile acuity, but tactile stimulation alone would not. Thirteen patients with complex regional pain syndrome (CRPS) of one limb underwent a waiting period and then approximately 2 weeks of tactile stimulation under two conditions: stimulation alone or discrimination between stimuli according to their diameter and location. There was no change in pain (100 mm VAS) or two-point discrimination (TPD) during a no-treatment waiting period, nor during the stimulation phase (p > 0.32 for both). Pain and TPD were lower after the discrimination phase [mean (95% CI) effect size for pain VAS = 27 mm (14-40 mm) and for TPD = 5.7 mm (2.9-8. ), p < 0.015 for both]. These gains were maintained at three-month follow-up. We conclude that tactile stimulation can decrease pain and increase tactile acuity when patients are required to discriminate between the type and location of tactile stimuli.

  11. Categorization influences illusory conjunctions.

    PubMed

    Esterman, Michael; Prinzmetal, William; Robertson, Lynn

    2004-08-01

    Illusory conjunctions (ICs) provide evidence for a binding problem that must be resolved in vision. Objects that are perceptually grouped are more likely to have their features erroneously conjoined. We examined whether semantic grouping, determined by category membership (letter vs. number), also influences illusory conjunction rates. Participants were instructed to detect an "L" or a "7" among briefly presented character strings and to report its color. Despite high shape discrimination accuracy, participants often made color conjunction errors, reporting instead the color of a distractor character, "O". This distractor could be ambiguously interpreted as a letter or a number. The status of the "O" was determined by other noncolored flanker characters, which were either letters or numbers. When both the target and flankers were of the same category, participants made more ICs than when the target and flankers were of different categories. This finding demonstrates that alphanumeric categorization can precede and subsequently influence binding.

  12. Optimal combination of illusory and luminance-defined 3-D surfaces: A role for ambiguity.

    PubMed

    Hartle, Brittney; Wilcox, Laurie M; Murray, Richard F

    2018-04-01

    The shape of the illusory surface in stereoscopic Kanizsa figures is determined by the interpolation of depth from the luminance edges of adjacent inducing elements. Despite ambiguity in the position of illusory boundaries, observers reliably perceive a coherent three-dimensional (3-D) surface. However, this ambiguity may contribute additional uncertainty to the depth percept beyond what is expected from measurement noise alone. We evaluated the intrinsic ambiguity of illusory boundaries by using a cue-combination paradigm to measure the reliability of depth percepts elicited by stereoscopic illusory surfaces. We assessed the accuracy and precision of depth percepts using 3-D Kanizsa figures relative to luminance-defined surfaces. The location of the surface peak was defined by illusory boundaries, luminance-defined edges, or both. Accuracy and precision were assessed using a depth-discrimination paradigm. A maximum likelihood linear cue combination model was used to evaluate the relative contribution of illusory and luminance-defined signals to the perceived depth of the combined surface. Our analysis showed that the standard deviation of depth estimates was consistent with an optimal cue combination model, but the points of subjective equality indicated that observers consistently underweighted the contribution of illusory boundaries. This systematic underweighting may reflect a combination rule that attributes additional intrinsic ambiguity to the location of the illusory boundary. Although previous studies show that illusory and luminance-defined contours share many perceptual similarities, our model suggests that ambiguity plays a larger role in the perceptual representation of illusory contours than of luminance-defined contours.

  13. Proprio-tactile integration for kinesthetic perception: an fMRI study.

    PubMed

    Kavounoudias, A; Roll, J P; Anton, J L; Nazarian, B; Roth, M; Roll, R

    2008-01-31

    This study aims to identify the cerebral networks involved in the integrative processing of somesthetic inputs for kinesthetic purposes. In particular, we investigated how muscle proprioceptive and tactile messages can result in a unified percept of one's own body movements. We stimulated either separately or conjointly these two sensory channels in order to evoke kinesthetic illusions of a clockwise rotation of 10 subjects' right hand in an fMRI environment. Results first show that, whether induced by a tactile or a proprioceptive stimulation, the kinesthetic illusion was accompanied by the activation of a very similar cerebral network including cortical and subcortical sensorimotor areas, which are also classically found in passive or imagined movement tasks. In addition, the strongest kinesthetic illusions occurred under the congruent proprio-tactile co-stimulation condition. They were specifically associated to brain area activations distinct from those evidenced under the unimodal stimulations: the inferior parietal lobule, the superior temporal sulcus, the insula-claustrum region, and the cerebellum. These findings support the hypothesis that heteromodal areas may subserve multisensory integrative mechanisms at cortical and subcortical levels. They also suggest the integrative processing might consist of detection of the spatial coherence between the two kinesthetic messages involving the inferior parietal lobule activity and of a detection of their temporal coincidence via a subcortical relay, the insula structure, usually linked to the relative synchrony of different stimuli. Finally, the involvement of the superior temporal sulcus in the feeling of biological movement and that of the cerebellum in the movement timing control are also discussed.

  14. Tactile agnosia. Underlying impairment and implications for normal tactile object recognition.

    PubMed

    Reed, C L; Caselli, R J; Farah, M J

    1996-06-01

    In a series of experimental investigations of a subject with a unilateral impairment of tactile object recognition without impaired tactile sensation, several issues were addressed. First, is tactile agnosia secondary to a general impairment of spatial cognition? On tests of spatial ability, including those directed at the same spatial integration process assumed to be taxed by tactile object recognition, the subject performed well, implying a more specific impairment of high level, modality specific tactile perception. Secondly, within the realm of high level tactile perception, is there a distinction between the ability to derive shape ('what') and spatial ('where') information? Our testing showed an impairment confined to shape perception. Thirdly, what aspects of shape perception are impaired in tactile agnosia? Our results indicate that despite accurate encoding of metric length and normal manual exploration strategies, the ability tactually to perceive objects with the impaired hand, deteriorated as the complexity of shape increased. In addition, asymmetrical performance was not found for other body surfaces (e.g. her feet). Our results suggest that tactile shape perception can be disrupted independent of general spatial ability, tactile spatial ability, manual shape exploration, or even the precise perception of metric length in the tactile modality.

  15. Genetically identified spinal interneurons integrating tactile afferents for motor control

    PubMed Central

    Panek, Izabela; Farah, Carl

    2015-01-01

    Our movements are shaped by our perception of the world as communicated by our senses. Perception of sensory information has been largely attributed to cortical activity. However, a prior level of sensory processing occurs in the spinal cord. Indeed, sensory inputs directly project to many spinal circuits, some of which communicate with motor circuits within the spinal cord. Therefore, the processing of sensory information for the purpose of ensuring proper movements is distributed between spinal and supraspinal circuits. The mechanisms underlying the integration of sensory information for motor control at the level of the spinal cord have yet to be fully described. Recent research has led to the characterization of spinal neuron populations that share common molecular identities. Identification of molecular markers that define specific populations of spinal neurons is a prerequisite to the application of genetic techniques devised to both delineate the function of these spinal neurons and their connectivity. This strategy has been used in the study of spinal neurons that receive tactile inputs from sensory neurons innervating the skin. As a result, the circuits that include these spinal neurons have been revealed to play important roles in specific aspects of motor function. We describe these genetically identified spinal neurons that integrate tactile information and the contribution of these studies to our understanding of how tactile information shapes motor output. Furthermore, we describe future opportunities that these circuits present for shedding light on the neural mechanisms of tactile processing. PMID:26445867

  16. The influence of trait anxiety and illusory kinesthesia on pain threshold.

    PubMed

    Imai, Ryota; Osumi, Michihiro; Ishigaki, Tomoya; Morioka, Shu

    2017-07-01

    [Purpose] It has also been reported that decreased activity in the reward pathway causes a decrease in brain activity in the descending pain control system in people with high trait anxiety. Activation of this system is dependent on both the reward pathway and motor areas. Recently, studies have also shown that motor areas are activated by illusory kinesthesia. It was aimed to explore whether anxiety trait modulates the influence of illusory kinesthesia on pain threshold. [Subjects and Methods] The pain threshold and trait anxiety at rest before vibratory tendon stimulation (the task) were measured. After the task, the pain threshold, the illusory kinesthesia angle, and the intensity of illusory kinesthesia for patients with and without illusory kinesthesia were measured. A total of 35 healthy right-handed students participated, among whom 22 and 13 were included in the illusion and no-illusion groups, respectively. [Results] There was a significant increase in the pain threshold after task completion in both groups; however, there was no statistically significant difference between the two groups. Correlational analysis revealed that State-Trait Anxiety Inventory-trait score correlated negatively with the pain threshold in the no-illusion group, but there was no correlation in the illusion group. [Conclusion] The pain threshold improved regardless of the size of trait anxiety in the illusion group, but did not improve merely through sensory input by vibratory stimulation in the no-illusion group. Thus, illusory kinesthesia has effect of increasing the pain threshold.

  17. Visuokinesthetic Perception of Hand Movement is Mediated by Cerebro–Cerebellar Interaction between the Left Cerebellum and Right Parietal Cortex

    PubMed Central

    Hagura, Nobuhiro; Oouchida, Yutaka; Aramaki, Yu; Okada, Tomohisa; Matsumura, Michikazu; Sadato, Norihiro

    2009-01-01

    Combination of visual and kinesthetic information is essential to perceive bodily movements. We conducted behavioral and functional magnetic resonance imaging experiments to investigate the neuronal correlates of visuokinesthetic combination in perception of hand movement. Participants experienced illusory flexion movement of their hand elicited by tendon vibration while they viewed video-recorded flexion (congruent: CONG) or extension (incongruent: INCONG) motions of their hand. The amount of illusory experience was graded by the visual velocities only when visual information regarding hand motion was concordant with kinesthetic information (CONG). The left posterolateral cerebellum was specifically recruited under the CONG, and this left cerebellar activation was consistent for both left and right hands. The left cerebellar activity reflected the participants' intensity of illusory hand movement under the CONG, and we further showed that coupling of activity between the left cerebellum and the “right” parietal cortex emerges during this visuokinesthetic combination/perception. The “left” cerebellum, working with the anatomically connected high-order bodily region of the “right” parietal cortex, participates in online combination of exteroceptive (vision) and interoceptive (kinesthesia) information to perceive hand movement. The cerebro–cerebellar interaction may underlie updating of one's “body image,” when perceiving bodily movement from visual and kinesthetic information. PMID:18453537

  18. Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review

    PubMed Central

    Ge, Chang; Wang, Z. Jane; Cretu, Edmond; Li, Xiaoou

    2017-01-01

    During the last decades, smart tactile sensing systems based on different sensing techniques have been developed due to their high potential in industry and biomedical engineering. However, smart tactile sensing technologies and systems are still in their infancy, as many technological and system issues remain unresolved and require strong interdisciplinary efforts to address them. This paper provides an overview of smart tactile sensing systems, with a focus on signal processing technologies used to interpret the measured information from tactile sensors and/or sensors for other sensory modalities. The tactile sensing transduction and principles, fabrication and structures are also discussed with their merits and demerits. Finally, the challenges that tactile sensing technology needs to overcome are highlighted. PMID:29149080

  19. Active Prior Tactile Knowledge Transfer for Learning Tactual Properties of New Objects

    PubMed Central

    Feng, Di

    2018-01-01

    Reusing the tactile knowledge of some previously-explored objects (prior objects) helps us to easily recognize the tactual properties of new objects. In this paper, we enable a robotic arm equipped with multi-modal artificial skin, like humans, to actively transfer the prior tactile exploratory action experiences when it learns the detailed physical properties of new objects. These experiences, or prior tactile knowledge, are built by the feature observations that the robot perceives from multiple sensory modalities, when it applies the pressing, sliding, and static contact movements on objects with different action parameters. We call our method Active Prior Tactile Knowledge Transfer (APTKT), and systematically evaluated its performance by several experiments. Results show that the robot improved the discrimination accuracy by around 10% when it used only one training sample with the feature observations of prior objects. By further incorporating the predictions from the observation models of prior objects as auxiliary features, our method improved the discrimination accuracy by over 20%. The results also show that the proposed method is robust against transferring irrelevant prior tactile knowledge (negative knowledge transfer). PMID:29466300

  20. A historical note on illusory contours in shadow writing.

    PubMed

    Vezzani, Stefano; Marino, Barbara F M

    2009-01-01

    It is widely accepted that illusory contours have been first displayed and discussed by Schumann (1900, Zeitschrift für Psychologie und Physiologie der Sinnesorgane 23 1-32). Here we show that, before him, Jastrow (1899, Popular Science Monthly 54 299-312) produced illusory contours consisting of a shadow word. A brief history of shadow writing in psychological literature from Jastrow to Brunswik is presented, in which the contributions of Pillsbury, Warren, Koffka, and Benussi are examined.

  1. Oscillatory phase dynamics in neural entrainment underpin illusory percepts of time.

    PubMed

    Herrmann, Björn; Henry, Molly J; Grigutsch, Maren; Obleser, Jonas

    2013-10-02

    Neural oscillatory dynamics are a candidate mechanism to steer perception of time and temporal rate change. While oscillator models of time perception are strongly supported by behavioral evidence, a direct link to neural oscillations and oscillatory entrainment has not yet been provided. In addition, it has thus far remained unaddressed how context-induced illusory percepts of time are coded for in oscillator models of time perception. To investigate these questions, we used magnetoencephalography and examined the neural oscillatory dynamics that underpin pitch-induced illusory percepts of temporal rate change. Human participants listened to frequency-modulated sounds that varied over time in both modulation rate and pitch, and judged the direction of rate change (decrease vs increase). Our results demonstrate distinct neural mechanisms of rate perception: Modulation rate changes directly affected listeners' rate percept as well as the exact frequency of the neural oscillation. However, pitch-induced illusory rate changes were unrelated to the exact frequency of the neural responses. The rate change illusion was instead linked to changes in neural phase patterns, which allowed for single-trial decoding of percepts. That is, illusory underestimations or overestimations of perceived rate change were tightly coupled to increased intertrial phase coherence and changes in cerebro-acoustic phase lag. The results provide insight on how illusory percepts of time are coded for by neural oscillatory dynamics.

  2. Betting on Illusory Patterns: Probability Matching in Habitual Gamblers.

    PubMed

    Gaissmaier, Wolfgang; Wilke, Andreas; Scheibehenne, Benjamin; McCanney, Paige; Barrett, H Clark

    2016-03-01

    Why do people gamble? A large body of research suggests that cognitive distortions play an important role in pathological gambling. Many of these distortions are specific cases of a more general misperception of randomness, specifically of an illusory perception of patterns in random sequences. In this article, we provide further evidence for the assumption that gamblers are particularly prone to perceiving illusory patterns. In particular, we compared habitual gamblers to a matched sample of community members with regard to how much they exhibit the choice anomaly 'probability matching'. Probability matching describes the tendency to match response proportions to outcome probabilities when predicting binary outcomes. It leads to a lower expected accuracy than the maximizing strategy of predicting the most likely event on each trial. Previous research has shown that an illusory perception of patterns in random sequences fuels probability matching. So does impulsivity, which is also reported to be higher in gamblers. We therefore hypothesized that gamblers will exhibit more probability matching than non-gamblers, which was confirmed in a controlled laboratory experiment. Additionally, gamblers scored much lower than community members on the cognitive reflection task, which indicates higher impulsivity. This difference could account for the difference in probability matching between the samples. These results suggest that gamblers are more willing to bet impulsively on perceived illusory patterns.

  3. Scalable, MEMS-enabled, vibrational tactile actuators for high resolution tactile displays

    NASA Astrophysics Data System (ADS)

    Xie, Xin; Zaitsev, Yuri; Velásquez-García, Luis Fernando; Teller, Seth J.; Livermore, Carol

    2014-12-01

    The design, fabrication, and characterization of a new type of tactile display for people with blindness or low vision is reported. Each tactile element comprises a piezoelectric extensional actuator that vibrates in plane, with a microfabricated scissor mechanism to convert the in-plane actuations into robust, higher-amplitude, out-of-plane (vertical) vibrations that are sensed with the finger pads. When the tactile elements are formed into a 2D array, information can be conveyed to the user by varying the pattern of vibrations in space and time. Analytical models and finite element analysis were used to design individual tactile elements, which were implemented with PZT actuators and both SU-8 and 3D-printed scissor amplifiers. The measured displacements of these 3 mm × 10 mm, MEMS-enabled tactile elements exceed 10 µm, in agreement with models, with measured forces exceeding 45 mN. The performance of the MEMS-enabled tactile elements is compared with the performance of larger, fully-macroscale tactile elements to demonstrate the scale dependence of the devices. The creation of a 28-element prototype is also reported, and the qualitative user experience with the individual tactile elements and displays is described.

  4. Illusory expectations can affect retrieval-monitoring accuracy.

    PubMed

    McDonough, Ian M; Gallo, David A

    2012-03-01

    The present study investigated how expectations, even when illusory, can affect the accuracy of memory decisions. Participants studied words presented in large or small font for subsequent memory tests. Replicating prior work, judgments of learning indicated that participants expected to remember large words better than small words, even though memory for these words was equivalent on a standard test of recognition memory and subjective judgments. Critically, we also included tests that instructed participants to selectively search memory for either large or small words, thereby allowing different memorial expectations to contribute to performance. On these tests we found reduced false recognition when searching memory for large words relative to small words, such that the size illusion paradoxically affected accuracy measures (d' scores) in the absence of actual memory differences. Additional evidence for the role of illusory expectations was that (a) the accuracy effect was obtained only when participants searched memory for the aspect of the stimuli corresponding to illusory expectations (size instead of color) and (b) the accuracy effect was eliminated on a forced-choice test that prevented the influence of memorial expectations. These findings demonstrate the critical role of memorial expectations in the retrieval-monitoring process. 2012 APA, all rights reserved

  5. Tactile Stimulation of the Face and the Production of Facial Expressions Activate Neurons in the Primate Amygdala

    PubMed Central

    Mosher, Clayton P.; Zimmerman, Prisca E.; Fuglevand, Andrew J.

    2016-01-01

    Abstract The majority of neurophysiological studies that have explored the role of the primate amygdala in the evaluation of social signals have relied on visual stimuli such as images of facial expressions. Vision, however, is not the only sensory modality that carries social signals. Both humans and nonhuman primates exchange emotionally meaningful social signals through touch. Indeed, social grooming in nonhuman primates and caressing touch in humans is critical for building lasting and reassuring social bonds. To determine the role of the amygdala in processing touch, we recorded the responses of single neurons in the macaque amygdala while we applied tactile stimuli to the face. We found that one-third of the recorded neurons responded to tactile stimulation. Although we recorded exclusively from the right amygdala, the receptive fields of 98% of the neurons were bilateral. A fraction of these tactile neurons were monitored during the production of facial expressions and during facial movements elicited occasionally by touch stimuli. Firing rates arising during the production of facial expressions were similar to those elicited by tactile stimulation. In a subset of cells, combining tactile stimulation with facial movement further augmented the firing rates. This suggests that tactile neurons in the amygdala receive input from skin mechanoceptors that are activated by touch and by compressions and stretches of the facial skin during the contraction of the underlying muscles. Tactile neurons in the amygdala may play a role in extracting the valence of touch stimuli and/or monitoring the facial expressions of self during social interactions. PMID:27752543

  6. Tactile Stimulation of the Face and the Production of Facial Expressions Activate Neurons in the Primate Amygdala.

    PubMed

    Mosher, Clayton P; Zimmerman, Prisca E; Fuglevand, Andrew J; Gothard, Katalin M

    2016-01-01

    The majority of neurophysiological studies that have explored the role of the primate amygdala in the evaluation of social signals have relied on visual stimuli such as images of facial expressions. Vision, however, is not the only sensory modality that carries social signals. Both humans and nonhuman primates exchange emotionally meaningful social signals through touch. Indeed, social grooming in nonhuman primates and caressing touch in humans is critical for building lasting and reassuring social bonds. To determine the role of the amygdala in processing touch, we recorded the responses of single neurons in the macaque amygdala while we applied tactile stimuli to the face. We found that one-third of the recorded neurons responded to tactile stimulation. Although we recorded exclusively from the right amygdala, the receptive fields of 98% of the neurons were bilateral. A fraction of these tactile neurons were monitored during the production of facial expressions and during facial movements elicited occasionally by touch stimuli. Firing rates arising during the production of facial expressions were similar to those elicited by tactile stimulation. In a subset of cells, combining tactile stimulation with facial movement further augmented the firing rates. This suggests that tactile neurons in the amygdala receive input from skin mechanoceptors that are activated by touch and by compressions and stretches of the facial skin during the contraction of the underlying muscles. Tactile neurons in the amygdala may play a role in extracting the valence of touch stimuli and/or monitoring the facial expressions of self during social interactions.

  7. Pure associative tactile agnosia for the left hand: clinical and anatomo-functional correlations.

    PubMed

    Veronelli, Laura; Ginex, Valeria; Dinacci, Daria; Cappa, Stefano F; Corbo, Massimo

    2014-09-01

    Associative tactile agnosia (TA) is defined as the inability to associate information about object sensory properties derived through tactile modality with previously acquired knowledge about object identity. The impairment is often described after a lesion involving the parietal cortex (Caselli, 1997; Platz, 1996). We report the case of SA, a right-handed 61-year-old man affected by first ever right hemispheric hemorrhagic stroke. The neurological examination was normal, excluding major somaesthetic and motor impairment; a brain magnetic resonance imaging (MRI) confirmed the presence of a right subacute hemorrhagic lesion limited to the post-central and supra-marginal gyri. A comprehensive neuropsychological evaluation detected a selective inability to name objects when handled with the left hand in the absence of other cognitive deficits. A series of experiments were conducted in order to assess each stage of tactile recognition processing using the same stimulus sets: materials, 3D geometrical shapes, real objects and letters. SA and seven matched controls underwent the same experimental tasks during four sessions in consecutive days. Tactile discrimination, recognition, pantomime, drawing after haptic exploration out of vision and tactile-visual matching abilities were assessed. In addition, we looked for the presence of a supra-modal impairment of spatial perception and of specific difficulties in programming exploratory movements during recognition. Tactile discrimination was intact for all the stimuli tested. In contrast, SA was able neither to recognize nor to pantomime real objects manipulated with the left hand out of vision, while he identified them with the right hand without hesitations. Tactile-visual matching was intact. Furthermore, SA was able to grossly reproduce the global shape in drawings but failed to extract details of objects after left-hand manipulation, and he could not identify objects after looking at his own drawings. This case

  8. Illusory conjunctions and perceptual grouping in a visual search task in schizophrenia.

    PubMed

    Carr, V J; Dewis, S A; Lewin, T J

    1998-07-27

    This report describes part of a series of experiments, conducted within the framework of feature integration theory, to determine whether patients with schizophrenia show deficits in preattentive processing. Thirty subjects with a DSM-III-R diagnosis of schizophrenia and 30 age-, gender-, and education-matched normal control subjects completed two computerized experimental tasks, a visual search task assessing the frequency of illusory conjunctions (i.e. false perceptions) under conditions of divided attention (Experiment 3) and a task which examined the effects of perceptual grouping on illusory conjunctions (Experiment 4). We also assessed current symptomatology and its relationship to task performance. Contrary to our hypotheses, schizophrenia subjects did not show higher rates of illusory conjunctions, and the influence of perceptual grouping on the frequency of illusory conjunctions was similar for schizophrenia and control subjects. Nonetheless, specific predictions from feature integration theory about the impact of different target types (Experiment 3) and perceptual groups (Experiment 4) on the likelihood of forming an illusory conjunction were strongly supported, thereby confirming the integrity of the experimental procedures. Overall, these studies revealed no firm evidence that schizophrenia is associated with a preattentive abnormality in visual search using stimuli that differ on the basis of physical characteristics.

  9. Is the Positive Illusory Bias Illusory? Examining Discrepant Self-Perceptions of Competence in Girls with ADHD

    ERIC Educational Resources Information Center

    Swanson, Erika N.; Owens, Elizabeth B.; Hinshaw, Stephen P.

    2012-01-01

    It has been claimed that excessively positive self-perceptions of competence are a key risk factor for concurrent and subsequent impairments in youth with attention-deficit/ hyperactivity disorder (ADHD). We examined whether girls with ADHD demonstrate positive illusory self-perceptions in scholastic competence, social acceptance, and behavioral…

  10. The Tactile Ethics of Soft Robotics: Designing Wisely for Human-Robot Interaction.

    PubMed

    Arnold, Thomas; Scheutz, Matthias

    2017-06-01

    Soft robots promise an exciting design trajectory in the field of robotics and human-robot interaction (HRI), promising more adaptive, resilient movement within environments as well as a safer, more sensitive interface for the objects or agents the robot encounters. In particular, tactile HRI is a critical dimension for designers to consider, especially given the onrush of assistive and companion robots into our society. In this article, we propose to surface an important set of ethical challenges for the field of soft robotics to meet. Tactile HRI strongly suggests that soft-bodied robots balance tactile engagement against emotional manipulation, model intimacy on the bonding with a tool not with a person, and deflect users from personally and socially destructive behavior the soft bodies and surfaces could normally entice.

  11. Surface regions of illusory images are detected with a slower processing speed than those of luminance-defined images.

    PubMed

    Mihaylova, Milena; Manahilov, Velitchko

    2010-11-24

    Research has shown that the processing time for discriminating illusory contours is longer than for real contours. We know, however, little whether the visual processes, associated with detecting regions of illusory surfaces, are also slower as those responsible for detecting luminance-defined images. Using a speed-accuracy trade-off (SAT) procedure, we measured accuracy as a function of processing time for detecting illusory Kanizsa-type and luminance-defined squares embedded in 2D static luminance noise. The data revealed that the illusory images were detected at slower processing speed than the real images, while the points in time, when accuracy departed from chance, were not significantly different for both stimuli. The classification images for detecting illusory and real squares showed that observers employed similar detection strategies using surface regions of the real and illusory squares. The lack of significant differences between the x-intercepts of the SAT functions for illusory and luminance-modulated stimuli suggests that the detection of surface regions of both images could be based on activation of a single mechanism (the dorsal magnocellular visual pathway). The slower speed for detecting illusory images as compared to luminance-defined images could be attributed to slower processes of filling-in of regions of illusory images within the dorsal pathway.

  12. Illusory inferences from a disjunction of conditionals: a new mental models account.

    PubMed

    Barrouillet, P; Lecas, J F

    2000-08-14

    (Johnson-Laird, P.N., & Savary, F. (1999, Illusory inferences: a novel class of erroneous deductions. Cognition, 71, 191-229.) have recently presented a mental models account, based on the so-called principle of truth, for the occurrence of inferences that are compelling but invalid. This article presents an alternative account of the illusory inferences resulting from a disjunction of conditionals. In accordance with our modified theory of mental models of the conditional, we show that the way individuals represent conditionals leads them to misinterpret the locus of the disjunction and prevents them from drawing conclusions from a false conditional, thus accounting for the compelling character of the illusory inference.

  13. Robot-Assisted Proprioceptive Training with Added Vibro-Tactile Feedback Enhances Somatosensory and Motor Performance.

    PubMed

    Cuppone, Anna Vera; Squeri, Valentina; Semprini, Marianna; Masia, Lorenzo; Konczak, Jürgen

    2016-01-01

    This study examined the trainability of the proprioceptive sense and explored the relationship between proprioception and motor learning. With vision blocked, human learners had to perform goal-directed wrist movements relying solely on proprioceptive/haptic cues to reach several haptically specified targets. One group received additional somatosensory movement error feedback in form of vibro-tactile cues applied to the skin of the forearm. We used a haptic robotic device for the wrist and implemented a 3-day training regimen that required learners to make spatially precise goal-directed wrist reaching movements without vision. We assessed whether training improved the acuity of the wrist joint position sense. In addition, we checked if sensory learning generalized to the motor domain and improved spatial precision of wrist tracking movements that were not trained. The main findings of the study are: First, proprioceptive acuity of the wrist joint position sense improved after training for the group that received the combined proprioceptive/haptic and vibro-tactile feedback (VTF). Second, training had no impact on the spatial accuracy of the untrained tracking task. However, learners who had received VTF significantly reduced their reliance on haptic guidance feedback when performing the untrained motor task. That is, concurrent VTF was highly salient movement feedback and obviated the need for haptic feedback. Third, VTF can be also provided by the limb not involved in the task. Learners who received VTF to the contralateral limb equally benefitted. In conclusion, somatosensory training can significantly enhance proprioceptive acuity within days when learning is coupled with vibro-tactile sensory cues that provide feedback about movement errors. The observable sensory improvements in proprioception facilitates motor learning and such learning may generalize to the sensorimotor control of the untrained motor tasks. The implications of these findings for

  14. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies

    PubMed Central

    Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F.

    2018-01-01

    Abstract Tactile sensing is an essential component in human–robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing. PMID:29297773

  15. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies.

    PubMed

    Ward-Cherrier, Benjamin; Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F

    2018-04-01

    Tactile sensing is an essential component in human-robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing.

  16. Illusory conjunctions reflect the time course of the attentional blink.

    PubMed

    Botella, Juan; Privado, Jesús; de Liaño, Beatriz Gil-Gómez; Suero, Manuel

    2011-07-01

    Illusory conjunctions in the time domain are binding errors for features from stimuli presented sequentially but in the same spatial position. A similar experimental paradigm is employed for the attentional blink (AB), an impairment of performance for the second of two targets when it is presented 200-500 msec after the first target. The analysis of errors along the time course of the AB allows the testing of models of illusory conjunctions. In an experiment, observers identified one (control condition) or two (experimental condition) letters in a specified color, so that illusory conjunctions in each response could be linked to specific positions in the series. Two items in the target colors (red and white, embedded in distractors of different colors) were employed in four conditions defined according to whether both targets were in the same or different colors. Besides the U-shaped function for hits, the errors were analyzed by calculating several response parameters reflecting characteristics such as the average position of the responses or the attentional suppression during the blink. The several error parameters cluster in two time courses, as would be expected from prevailing models of the AB. Furthermore, the results match the predictions from Botella, Barriopedro, and Suero's (Journal of Experimental Psychology: Human Perception and Performance, 27, 1452-1467, 2001) model for illusory conjunctions.

  17. To What Extent Do Gestalt Grouping Principles Influence Tactile Perception?

    ERIC Educational Resources Information Center

    Gallace, Alberto; Spence, Charles

    2011-01-01

    Since their formulation by the Gestalt movement more than a century ago, the principles of perceptual grouping have primarily been investigated in the visual modality and, to a lesser extent, in the auditory modality. The present review addresses the question of whether the same grouping principles also affect the perception of tactile stimuli.…

  18. A Computational Model of a Descending Mechanosensory Pathway Involved in Active Tactile Sensing

    PubMed Central

    Ache, Jan M.; Dürr, Volker

    2015-01-01

    Many animals, including humans, rely on active tactile sensing to explore the environment and negotiate obstacles, especially in the dark. Here, we model a descending neural pathway that mediates short-latency proprioceptive information from a tactile sensor on the head to thoracic neural networks. We studied the nocturnal stick insect Carausius morosus, a model organism for the study of adaptive locomotion, including tactually mediated reaching movements. Like mammals, insects need to move their tactile sensors for probing the environment. Cues about sensor position and motion are therefore crucial for the spatial localization of tactile contacts and the coordination of fast, adaptive motor responses. Our model explains how proprioceptive information about motion and position of the antennae, the main tactile sensors in insects, can be encoded by a single type of mechanosensory afferents. Moreover, it explains how this information is integrated and mediated to thoracic neural networks by a diverse population of descending interneurons (DINs). First, we quantified responses of a DIN population to changes in antennal position, motion and direction of movement. Using principal component (PC) analysis, we find that only two PCs account for a large fraction of the variance in the DIN response properties. We call the two-dimensional space spanned by these PCs ‘coding-space’ because it captures essential features of the entire DIN population. Second, we model the mechanoreceptive input elements of this descending pathway, a population of proprioceptive mechanosensory hairs monitoring deflection of the antennal joints. Finally, we propose a computational framework that can model the response properties of all important DIN types, using the hair field model as its only input. This DIN model is validated by comparison of tuning characteristics, and by mapping the modelled neurons into the two-dimensional coding-space of the real DIN population. This reveals the

  19. Perception of Elasticity in the Kinetic Illusory Object with Phase Differences in Inducer Motion

    PubMed Central

    Masuda, Tomohiro; Sato, Kazuki; Murakoshi, Takuma; Utsumi, Ken; Kimura, Atsushi; Shirai, Nobu; Kanazawa, So; Yamaguchi, Masami K.; Wada, Yuji

    2013-01-01

    Background It is known that subjective contours are perceived even when a figure involves motion. However, whether this includes the perception of rigidity or deformation of an illusory surface remains unknown. In particular, since most visual stimuli used in previous studies were generated in order to induce illusory rigid objects, the potential perception of material properties such as rigidity or elasticity in these illusory surfaces has not been examined. Here, we elucidate whether the magnitude of phase difference in oscillation influences the visual impressions of an object's elasticity (Experiment 1) and identify whether such elasticity perceptions are accompanied by the shape of the subjective contours, which can be assumed to be strongly correlated with the perception of rigidity (Experiment 2). Methodology/Principal Findings In Experiment 1, the phase differences in the oscillating motion of inducers were controlled to investigate whether they influenced the visual impression of an illusory object's elasticity. The results demonstrated that the impression of the elasticity of an illusory surface with subjective contours was systematically flipped with the degree of phase difference. In Experiment 2, we examined whether the subjective contours of a perceived object appeared linear or curved using multi-dimensional scaling analysis. The results indicated that the contours of a moving illusory object were perceived as more curved than linear in all phase-difference conditions. Conclusions/Significance These findings suggest that the phase difference in an object's motion is a significant factor in the material perception of motion-related elasticity. PMID:24205281

  20. Visual Enhancement of Illusory Phenomenal Accents in Non-Isochronous Auditory Rhythms

    PubMed Central

    2016-01-01

    Musical rhythms encompass temporal patterns that often yield regular metrical accents (e.g., a beat). There have been mixed results regarding perception as a function of metrical saliency, namely, whether sensitivity to a deviant was greater in metrically stronger or weaker positions. Besides, effects of metrical position have not been examined in non-isochronous rhythms, or with respect to multisensory influences. This study was concerned with two main issues: (1) In non-isochronous auditory rhythms with clear metrical accents, how would sensitivity to a deviant be modulated by metrical positions? (2) Would the effects be enhanced by multisensory information? Participants listened to strongly metrical rhythms with or without watching a point-light figure dance to the rhythm in the same meter, and detected a slight loudness increment. Both conditions were presented with or without an auditory interference that served to impair auditory metrical perception. Sensitivity to a deviant was found greater in weak beat than in strong beat positions, consistent with the Predictive Coding hypothesis and the idea of metrically induced illusory phenomenal accents. The visual rhythm of dance hindered auditory detection, but more so when the latter was itself less impaired. This pattern suggested that the visual and auditory rhythms were perceptually integrated to reinforce metrical accentuation, yielding more illusory phenomenal accents and thus lower sensitivity to deviants, in a manner consistent with the principle of inverse effectiveness. Results were discussed in the predictive framework for multisensory rhythms involving observed movements and possible mediation of the motor system. PMID:27880850

  1. Artificial gravity: head movements during short-radius centrifugation

    NASA Technical Reports Server (NTRS)

    Young, L. R.; Hecht, H.; Lyne, L. E.; Sienko, K. H.; Cheung, C. C.; Kavelaars, J.

    2001-01-01

    Short-radius centrifugation is a potential countermeasure to long-term weightlessness. Unfortunately, head movements in a rotating environment induce serious discomfort, non-compensatory vestibulo-ocular reflexes, and subjective illusions of body tilt. In two experiments we investigated the effects of pitch and yaw head movements in participants placed supine on a rotating bed with their head at the center of rotation, feet at the rim. The vast majority of participants experienced motion sickness, inappropriate vertical nystagmus and illusory tilt and roll as predicted by a semicircular canal model. However, a small but significant number of the 28 participants experienced tilt in the predicted plane but in the opposite direction. Heart rate was elevated following one-second duration head turns. Significant adaptation occurred following a series of head turns in the light. Vertical nystagmus, motion sickness and illusory tilt all decreased with adaptation. Consequences for artificial gravity produced by short-radius centrifuges as a countermeasure are discussed. Grant numbers: NCC 9-58. c 2001. Elsevier Science Ltd. All rights reserved.

  2. Illusory correlation: a function of availability or representativeness heuristics?

    PubMed

    MacDonald, M G

    2000-08-01

    The present study sought to investigate the illusory correlation phenomenon by experimentally manipulating the availability of information through the use of the "lag" effect (Madigan, 1969). Seventy-four university students voluntarily participated in this study. Similar to Starr and Katkin's (1969) methodology, subjects were visually presented with each possible combination of four experimental problem descriptions and four sentence completions that were paired and shown twice at each of four lags (i.e., with 0, 2, 8 and 20 intervening variables). Subjects were required to make judgements concerning the frequency with which sentence completions and problem descriptions co-occurred. In agreement with previous research (Starr & Katkin, 1969), the illusory correlation effect was found for specific descriptions and sentence completions. Results also yielded a significant effect of lag for mean ratings between 0 and 2 lags; however, there was no reliable increase in judged co-occurrence at lags 8 and 20. Evidence failed to support the hypothesis that greater availability, through the experimental manipulation of lag, would result in increased frequency of co-occurrence judgements. Findings indicate that, in the present study, the illusory correlation effect is probably due to a situational bias based on the representativeness heuristic.

  3. [Passive tactile stimulation and its clinical and neurophysiological repercussions (P300) in blind children with symptoms of attention deficit disorder].

    PubMed

    Serrano-Marugán, Isabel; Herrera, Begoña; Romero, Sara; Nogales, Ramón; Poch-Broto, Joaquín; Quintero, Javier; Ortiz, Tomás

    2014-02-24

    Tactile stimulation is key for the posterior brain re-organization activity and attention processes, however the impact of tactile stimulation on attention deficit disorder (ADD) in blind children remains unexplored. We carried out a study with children having or not ADD (four per group). The subjects have been exposed during six months to tactile stimulation protocol consisting in two daily sessions (morning and afternoon sessions) of 30 minutes each. We have measured the ability to detect an infrequent tactile stimulus, reaction time, latency of P300, sources of brain activity, and ADD clinical symptoms, before and after tactile training. Passive tactile stimulation significantly improves ADD clinical symptoms, particularly attention, behavior and self-control of involuntary movements and tics. In addition, tactile stimulation changes the pattern of brain activity in ADD blind children inducing activity in frontal and occipital areas, which could be associated to a compensation of the attention deficit. Passive tactile stimulation training may improve ADD clinical symptoms and can reorganize the pattern of brain activity in blind ADD children.

  4. An overview of tactile sensing

    NASA Technical Reports Server (NTRS)

    Agrawal, Rajeev; Jain, Ramesh

    1986-01-01

    Existing or proposed tactile sensors are reviewed. General considerations involved in tactile sensing and various performance criteria are discussed. Typical specifications to be expected from the sensors are also described. A representative set of present day tactile sensors is studied. Finally, some of the proposed recognition systems using tactile sensing are described.

  5. Illusion of arm movement evoked by tendon vibration in patients with spinal cord injury.

    PubMed

    Fusco, Gabriele; Tidoni, Emmanuele; Barone, Nicola; Pilati, Claudio; Aglioti, Salvatore Maria

    2016-09-21

    Studies in healthy people show that stimulation of muscle spindles through frequency-specific tendon vibration (TV) induces the illusory perception of movement. Following spinal cord injury (SCI), motor and sensory connections between the brain and parts of the body below-the-lesion level are partially or totally impaired. The present investigation is a descriptive study aimed to investigate whether people living with SCI may experience movement illusions comparable to a control group. Healthy and people with SCI were asked to report on three illusion-related features (Vividness, Duration, Illusory Extension) after receiving 70 Hz TV on the biceps brachii tendon of both arms. Two different forces of stimulation were applied: 2.4 N and 4.2 N. Both patients and controls were susceptible to the kinesthetic illusion. However patients presented lower sensitivity to TV than healthy subjects. Participants rated stronger illusions of movement after 4.2 N than 2.4 N stimulation in all the three illusion-related features. Further, patients reported atypical illusory experiences of movement (e.g. as if the arm wanted to extend, or a sensation of pushing against something) that may reflect different reorganization processes following spinal cord injury. The study provides a preliminary evidence of the possible use of the proprioceptive stimulation in the upper limbs of people living with SCI. Results are discussed in the light of recent advancements of brain-computer applications based on motor imagery for the control of neuroprosthetic and robotic devices in patients with severe sensorimotor deficits.

  6. Illusory conjunctions are alive and well: a reply to Donk (1999).

    PubMed

    Prinzmetal, W; Diedrichsen, J; Ivry, R B

    2001-06-01

    When presented with a red T and a green O, observers occasionally make conjunction responses and indicate that they saw a green T. These errors have been interpreted as reflecting separable processing stages of feature detection and integration with the illusory conjunctions arising from a failure at the integration stage. Recently, M. Donk (1999) asserted that the phenomenon of illusory conjunctions is an artifact. Conjunction reports are actually the result of confusing a nontarget item (O in the example above) for a target item (the letter T) and (correctly) reporting the color associated with the (incorrectly) selected target. The authors demonstrate that although target-nontarget confusion errors are a potential source of conjunction reports, there is a plethora of findings that cannot be accounted for by this confusion model. A review of the literature indicates that in many studies, illusory conjunctions do result from a failure to properly integrate features.

  7. Tactile Signing with One-Handed Perception

    ERIC Educational Resources Information Center

    Mesch, Johanna

    2013-01-01

    Tactile signing among persons with deaf-blindness is not homogenous; rather, like other forms of language, it exhibits variation, especially in turn taking. Early analyses of tactile Swedish Sign Language, tactile Norwegian Sign Language, and tactile French Sign Language focused on tactile communication with four hands, in which partially blind or…

  8. Why Early Tactile Speech Aids May Have Failed: No Perceptual Integration of Tactile and Auditory Signals.

    PubMed

    Rizza, Aurora; Terekhov, Alexander V; Montone, Guglielmo; Olivetti-Belardinelli, Marta; O'Regan, J Kevin

    2018-01-01

    Tactile speech aids, though extensively studied in the 1980's and 1990's, never became a commercial success. A hypothesis to explain this failure might be that it is difficult to obtain true perceptual integration of a tactile signal with information from auditory speech: exploitation of tactile cues from a tactile aid might require cognitive effort and so prevent speech understanding at the high rates typical of everyday speech. To test this hypothesis, we attempted to create true perceptual integration of tactile with auditory information in what might be considered the simplest situation encountered by a hearing-impaired listener. We created an auditory continuum between the syllables /BA/ and /VA/, and trained participants to associate /BA/ to one tactile stimulus and /VA/ to another tactile stimulus. After training, we tested if auditory discrimination along the continuum between the two syllables could be biased by incongruent tactile stimulation. We found that such a bias occurred only when the tactile stimulus was above, but not when it was below its previously measured tactile discrimination threshold. Such a pattern is compatible with the idea that the effect is due to a cognitive or decisional strategy, rather than to truly perceptual integration. We therefore ran a further study (Experiment 2), where we created a tactile version of the McGurk effect. We extensively trained two Subjects over 6 days to associate four recorded auditory syllables with four corresponding apparent motion tactile patterns. In a subsequent test, we presented stimulation that was either congruent or incongruent with the learnt association, and asked Subjects to report the syllable they perceived. We found no analog to the McGurk effect, suggesting that the tactile stimulation was not being perceptually integrated with the auditory syllable. These findings strengthen our hypothesis according to which tactile aids failed because integration of tactile cues with auditory speech

  9. Why Early Tactile Speech Aids May Have Failed: No Perceptual Integration of Tactile and Auditory Signals

    PubMed Central

    Rizza, Aurora; Terekhov, Alexander V.; Montone, Guglielmo; Olivetti-Belardinelli, Marta; O’Regan, J. Kevin

    2018-01-01

    Tactile speech aids, though extensively studied in the 1980’s and 1990’s, never became a commercial success. A hypothesis to explain this failure might be that it is difficult to obtain true perceptual integration of a tactile signal with information from auditory speech: exploitation of tactile cues from a tactile aid might require cognitive effort and so prevent speech understanding at the high rates typical of everyday speech. To test this hypothesis, we attempted to create true perceptual integration of tactile with auditory information in what might be considered the simplest situation encountered by a hearing-impaired listener. We created an auditory continuum between the syllables /BA/ and /VA/, and trained participants to associate /BA/ to one tactile stimulus and /VA/ to another tactile stimulus. After training, we tested if auditory discrimination along the continuum between the two syllables could be biased by incongruent tactile stimulation. We found that such a bias occurred only when the tactile stimulus was above, but not when it was below its previously measured tactile discrimination threshold. Such a pattern is compatible with the idea that the effect is due to a cognitive or decisional strategy, rather than to truly perceptual integration. We therefore ran a further study (Experiment 2), where we created a tactile version of the McGurk effect. We extensively trained two Subjects over 6 days to associate four recorded auditory syllables with four corresponding apparent motion tactile patterns. In a subsequent test, we presented stimulation that was either congruent or incongruent with the learnt association, and asked Subjects to report the syllable they perceived. We found no analog to the McGurk effect, suggesting that the tactile stimulation was not being perceptually integrated with the auditory syllable. These findings strengthen our hypothesis according to which tactile aids failed because integration of tactile cues with auditory speech

  10. Tactile Evaluation Feedback System for Multi-Layered Structure Inspired by Human Tactile Perception Mechanism.

    PubMed

    Hashim, Iza Husna Mohamad; Kumamoto, Shogo; Takemura, Kenjiro; Maeno, Takashi; Okuda, Shin; Mori, Yukio

    2017-11-11

    Tactile sensation is one type of valuable feedback in evaluating a product. Conventionally, sensory evaluation is used to get direct subjective responses from the consumers, in order to improve the product's quality. However, this method is a time-consuming and costly process. Therefore, this paper proposes a novel tactile evaluation system that can give tactile feedback from a sensor's output. The main concept of this system is hierarchically layering the tactile sensation, which is inspired by the flow of human perception. The tactile sensation is classified from low-order of tactile sensation (LTS) to high-order of tactile sensation (HTS), and also to preference. Here, LTS will be correlated with physical measures. Furthermore, the physical measures that are used to correlate with LTS are selected based on four main aspects of haptic information (roughness, compliance, coldness, and slipperiness), which are perceived through human tactile sensors. By using statistical analysis, the correlation between each hierarchy was obtained, and the preference was derived in terms of physical measures. A verification test was conducted by using unknown samples to determine the reliability of the system. The results showed that the system developed was capable of estimating preference with an accuracy of approximately 80%.

  11. On Known Unknowns: Fluency and the Neural Mechanisms of Illusory Truth

    PubMed Central

    Wang, Wei-Chun; Brashier, Nadia M.; Wing, Erik A.; Marsh, Elizabeth J.; Cabeza, Roberto

    2016-01-01

    The “illusory truth” effect refers to the phenomenon whereby repetition of a statement increases its likelihood of being judged true. This phenomenon has important implications for how we come to believe oft-repeated information that may be misleading or unknown. Behavioral evidence indicates that fluency or the subjective ease experienced while processing a statement underlies this effect. This suggests that illusory truth should be mediated by brain regions previously linked to fluency, such as the perirhinal cortex (PRC). To investigate this possibility, we scanned participants with fMRI while they rated the truth of unknown statements, half of which were presented earlier (i.e., repeated). The only brain region that showed an interaction between repetition and ratings of perceived truth was PRC, where activity increased with truth ratings for repeated, but not for new, statements. This finding supports the hypothesis that illusory truth is mediated by a fluency mechanism and further strengthens the link between PRC and fluency. PMID:26765947

  12. Multisensory Integration in the Virtual Hand Illusion with Active Movement

    PubMed Central

    Satoh, Satoru; Hachimura, Kozaburo

    2016-01-01

    Improving the sense of immersion is one of the core issues in virtual reality. Perceptual illusions of ownership can be perceived over a virtual body in a multisensory virtual reality environment. Rubber Hand and Virtual Hand Illusions showed that body ownership can be manipulated by applying suitable visual and tactile stimulation. In this study, we investigate the effects of multisensory integration in the Virtual Hand Illusion with active movement. A virtual xylophone playing system which can interactively provide synchronous visual, tactile, and auditory stimulation was constructed. We conducted two experiments regarding different movement conditions and different sensory stimulations. Our results demonstrate that multisensory integration with free active movement can improve the sense of immersion in virtual reality. PMID:27847822

  13. Optokinetic motion sickness - Attenuation of visually-induced apparent self-rotation by passive head movements

    NASA Technical Reports Server (NTRS)

    Teixeira, R. A.; Lackner, J. R.

    1979-01-01

    An experimental study was conducted on seven normal subjects to evaluate the effectiveness of passive head movements in suppressing the optokinetically-induced illusory self-rotation. Visual simulation was provided by a servo-controlled optokinetic drum. Each subject participated in two experimental sessions. In one condition, the subject's head remained stationary while he gazed passively at a moving stripe pattern. In the other, he gazed passively and relaxed his neck muscles while his head was rotated from side to side. It appears that suppression of optokinetically-induced illusory self-rotation with passive head movements results from the operation of a spatial constancy mechanism interrelating visual, vestibular, and kinesthetic information on ongoing body orientation. The results support the view that optokinetic 'motion sickness' is related, at least in part, to an oculomotor disturbance rather than a visually triggered disturbance of specifically vestibular etiology.

  14. Seeking Positive Experiences Can Produce Illusory Correlations

    ERIC Educational Resources Information Center

    Denrell, Jerker; Le Mens, Gael

    2011-01-01

    Individuals tend to select again alternatives about which they have positive impressions and to avoid alternatives about which they have negative impressions. Here we show how this sequential sampling feature of the information acquisition process leads to the emergence of an illusory correlation between estimates of the attributes of…

  15. Influence of Visual Motion, Suggestion, and Illusory Motion on Self-Motion Perception in the Horizontal Plane.

    PubMed

    Rosenblatt, Steven David; Crane, Benjamin Thomas

    2015-01-01

    A moving visual field can induce the feeling of self-motion or vection. Illusory motion from static repeated asymmetric patterns creates a compelling visual motion stimulus, but it is unclear if such illusory motion can induce a feeling of self-motion or alter self-motion perception. In these experiments, human subjects reported the perceived direction of self-motion for sway translation and yaw rotation at the end of a period of viewing set visual stimuli coordinated with varying inertial stimuli. This tested the hypothesis that illusory visual motion would influence self-motion perception in the horizontal plane. Trials were arranged into 5 blocks based on stimulus type: moving star field with yaw rotation, moving star field with sway translation, illusory motion with yaw, illusory motion with sway, and static arrows with sway. Static arrows were used to evaluate the effect of cognitive suggestion on self-motion perception. Each trial had a control condition; the illusory motion controls were altered versions of the experimental image, which removed the illusory motion effect. For the moving visual stimulus, controls were carried out in a dark room. With the arrow visual stimulus, controls were a gray screen. In blocks containing a visual stimulus there was an 8s viewing interval with the inertial stimulus occurring over the final 1s. This allowed measurement of the visual illusion perception using objective methods. When no visual stimulus was present, only the 1s motion stimulus was presented. Eight women and five men (mean age 37) participated. To assess for a shift in self-motion perception, the effect of each visual stimulus on the self-motion stimulus (cm/s) at which subjects were equally likely to report motion in either direction was measured. Significant effects were seen for moving star fields for both translation (p = 0.001) and rotation (p<0.001), and arrows (p = 0.02). For the visual motion stimuli, inertial motion perception was shifted in the

  16. Suppressive and enhancing effects in early visual cortex during illusory shape perception: A comment on.

    PubMed

    Moors, Pieter

    2015-01-01

    In a recent functional magnetic resonance imaging study, Kok and de Lange (2014) observed that BOLD activity for a Kanizsa illusory shape stimulus, in which pacmen-like inducers elicit an illusory shape percept, was either enhanced or suppressed relative to a nonillusory control configuration depending on whether the spatial profile of BOLD activity in early visual cortex was related to the illusory shape or the inducers, respectively. The authors argued that these findings fit well with the predictive coding framework, because top-down predictions related to the illusory shape are not met with bottom-up sensory input and hence the feedforward error signal is enhanced. Conversely, for the inducing elements, there is a match between top-down predictions and input, leading to a decrease in error. Rather than invoking predictive coding as the explanatory framework, the suppressive effect related to the inducers might be caused by neural adaptation to perceptually stable input due to the trial sequence used in the experiment.

  17. Active tactile exploration using a brain-machine-brain interface.

    PubMed

    O'Doherty, Joseph E; Lebedev, Mikhail A; Ifft, Peter J; Zhuang, Katie Z; Shokur, Solaiman; Bleuler, Hannes; Nicolelis, Miguel A L

    2011-10-05

    Brain-machine interfaces use neuronal activity recorded from the brain to establish direct communication with external actuators, such as prosthetic arms. It is hoped that brain-machine interfaces can be used to restore the normal sensorimotor functions of the limbs, but so far they have lacked tactile sensation. Here we report the operation of a brain-machine-brain interface (BMBI) that both controls the exploratory reaching movements of an actuator and allows signalling of artificial tactile feedback through intracortical microstimulation (ICMS) of the primary somatosensory cortex. Monkeys performed an active exploration task in which an actuator (a computer cursor or a virtual-reality arm) was moved using a BMBI that derived motor commands from neuronal ensemble activity recorded in the primary motor cortex. ICMS feedback occurred whenever the actuator touched virtual objects. Temporal patterns of ICMS encoded the artificial tactile properties of each object. Neuronal recordings and ICMS epochs were temporally multiplexed to avoid interference. Two monkeys operated this BMBI to search for and distinguish one of three visually identical objects, using the virtual-reality arm to identify the unique artificial texture associated with each. These results suggest that clinical motor neuroprostheses might benefit from the addition of ICMS feedback to generate artificial somatic perceptions associated with mechanical, robotic or even virtual prostheses.

  18. Pain sensitivity and tactile spatial acuity are altered in healthy musicians as in chronic pain patients

    PubMed Central

    Zamorano, Anna M.; Riquelme, Inmaculada; Kleber, Boris; Altenmüller, Eckart; Hatem, Samar M.; Montoya, Pedro

    2015-01-01

    Extensive training of repetitive and highly skilled movements, as it occurs in professional classical musicians, may lead to changes in tactile sensitivity and corresponding cortical reorganization of somatosensory cortices. It is also known that professional musicians frequently experience musculoskeletal pain and pain-related symptoms during their careers. The present study aimed at understanding the complex interaction between chronic pain and music training with respect to somatosensory processing. For this purpose, tactile thresholds (mechanical detection, grating orientation, two-point discrimination) and subjective ratings to thermal and pressure pain stimuli were assessed in 17 professional musicians with chronic pain, 30 pain-free musicians, 20 non-musicians with chronic pain, and 18 pain-free non-musicians. We found that pain-free musicians displayed greater touch sensitivity (i.e., lower mechanical detection thresholds), lower tactile spatial acuity (i.e., higher grating orientation thresholds) and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. Moreover, we also found that musicians and non-musicians with chronic pain presented lower tactile spatial acuity and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. The significant increment of pain sensitivity together with decreased spatial discrimination in pain-free musicians and the similarity of results found in chronic pain patients, suggests that the extensive training of repetitive and highly skilled movements in classical musicians could be considered as a risk factor for developing chronic pain, probably due to use-dependent plastic changes elicited in somatosensory pathways. PMID:25610384

  19. Implicit and Explicit Illusory Correlation as a Function of Political Ideology

    PubMed Central

    Carraro, Luciana; Negri, Paolo; Castelli, Luigi; Pastore, Massimiliano

    2014-01-01

    Research has demonstrated that people who embrace different ideological orientations often show differences at the level of basic cognitive processes. For instance, conservatives (vs. liberals) display an automatic selective attention for negative (vs. positive) stimuli, and tend to more easily form illusory correlations between negative information and minority groups. In the present work, we further explored this latter effect by examining whether it only involves the formation of explicit attitudes or it extends to implicit attitudes. To this end, following the typical illusory correlation paradigm, participants were presented with members of two numerically different groups (majority and minority) each performing either a positive or negative behaviour. Negative behaviors were relatively infrequent, and the proportion of positive and negative behaviors within each group was the same. Next, explicit and implicit (i.e., IAT-measured) attitudes were assessed. Results showed that conservatives (vs. liberals) displayed stronger explicit as well as implicit illusory correlations effects, forming more negative attitudes toward the minority (vs. majority) group at both the explicit and implicit level. PMID:24820311

  20. Implicit and explicit illusory correlation as a function of political ideology.

    PubMed

    Carraro, Luciana; Negri, Paolo; Castelli, Luigi; Pastore, Massimiliano

    2014-01-01

    Research has demonstrated that people who embrace different ideological orientations often show differences at the level of basic cognitive processes. For instance, conservatives (vs. liberals) display an automatic selective attention for negative (vs. positive) stimuli, and tend to more easily form illusory correlations between negative information and minority groups. In the present work, we further explored this latter effect by examining whether it only involves the formation of explicit attitudes or it extends to implicit attitudes. To this end, following the typical illusory correlation paradigm, participants were presented with members of two numerically different groups (majority and minority) each performing either a positive or negative behaviour. Negative behaviors were relatively infrequent, and the proportion of positive and negative behaviors within each group was the same. Next, explicit and implicit (i.e., IAT-measured) attitudes were assessed. Results showed that conservatives (vs. liberals) displayed stronger explicit as well as implicit illusory correlations effects, forming more negative attitudes toward the minority (vs. majority) group at both the explicit and implicit level.

  1. Tactile Sensitivity in Asperger Syndrome

    ERIC Educational Resources Information Center

    Blakemore, Sarah-Jayne; Tavassoli, Teresa; Calo, Susana; Thomas, Richard M.; Catmur, Caroline; Frith, Uta; Haggard, Patrick

    2006-01-01

    People with autism and Asperger syndrome are anecdotally said to be hypersensitive to touch. In two experiments, we measured tactile thresholds and suprathreshold tactile sensitivity in a group of adults with Asperger syndrome. In the first experiment, tactile perceptual thresholds were measured. Two frequencies of vibrotactile stimulation were…

  2. Dissociated active and passive tactile shape recognition: a case study of pure tactile apraxia.

    PubMed

    Valenza, N; Ptak, R; Zimine, I; Badan, M; Lazeyras, F; Schnider, A

    2001-11-01

    Disorders of tactile object recognition (TOR) may result from primary motor or sensory deficits or higher cognitive impairment of tactile shape representations or semantic memory. Studies with healthy participants suggest the existence of exploratory motor procedures directly linked to the extraction of specific properties of objects. A pure deficit of these procedures without concomitant gnostic disorders has never been described in a brain-damaged patient. Here, we present a patient with a right hemispheric infarction who, in spite of intact sensorimotor functions, had impaired TOR with the left hand. Recognition of 2D shapes and objects was severely deficient under the condition of spontaneous exploration. Tactile exploration of shapes was disorganized and exploratory procedures, such as the contour-following strategy, which is necessary to identify the precise shape of an object, were severely disturbed. However, recognition of 2D shapes under manually or verbally guided exploration and the recognition of shapes traced on the skin were intact, indicating a dissociation in shape recognition between active and passive touch. Functional MRI during sensory stimulation of the left hand showed preserved activation of the spared primary sensory cortex in the right hemisphere. We interpret the deficit of our patient as a pure tactile apraxia without tactile agnosia, i.e. a specific inability to use tactile feedback to generate the exploratory procedures necessary for tactile shape recognition.

  3. Volitional Control of Movement: The Physiology of Free Will

    PubMed Central

    Hallett, Mark

    2007-01-01

    This review deals with the physiology of the initiation of a voluntary movement and the appreciation of whether it is voluntary or not. I argue that free will is not a driving force for movement, but a conscious awareness concerning the nature of the movement. Movement initiation and the perception of willing the movement can be separately manipulated. Movement is generated subconsciously, and the conscious sense of volition comes later, but the exact time of this event is difficult to assess because of the potentially illusory nature of introspection. Neurological disorders of volition are also reviewed. The evidence suggests that movement is initiated in frontal lobe, particularly the mesial areas, and the sense of volition arises as the result of a corollary discharge likely involving multiple areas with reciprocal connections including those in the parietal lobe and insular cortex. PMID:17466580

  4. The Positive Illusory Bias in Children and Adolescents With ADHD: Further Evidence.

    PubMed

    Volz-Sidiropoulou, Eftychia; Boecker, Maren; Gauggel, Siegfried

    2016-02-01

    This study aimed to examine the accuracy of self-reports of children and adolescents with ADHD in evaluating activity limitations. Self-reports of children/adolescents with ADHD (n = 89) were compared with those of nonreferred children (n = 94), relative to parent reports about children's competence. Competence was measured with a 34-item rating scale. Behavioral disorders were documented with the Child Behavior Checklist. Children/adolescents with ADHD were much more likely than controls to overestimate their competence in certain daily activities relative to parent reports, demonstrating a positive illusory bias. Positive illusory bias was found to be pronounced in activities, which were expected to be affected by symptoms of ADHD. Overestimations of competencies were more likely to be accompanied with externalizing problems. Results support the presence of the positive illusory bias also in the domain of everyday life activities. Improvement of self-evaluation of competencies should become a focus of treatment. © The Author(s) 2013.

  5. Directional harmonic theory: a computational Gestalt model to account for illusory contour and vertex formation.

    PubMed

    Lehar, Steven

    2003-01-01

    Visual illusions and perceptual grouping phenomena offer an invaluable tool for probing the computational mechanism of low-level visual processing. Some illusions, like the Kanizsa figure, reveal illusory contours that form edges collinear with the inducing stimulus. This kind of illusory contour has been modeled by neural network models by way of cells equipped with elongated spatial receptive fields designed to detect and complete the collinear alignment. There are, however, other illusory groupings which are not so easy to account for in neural network terms. The Ehrenstein illusion exhibits an illusory contour that forms a contour orthogonal to the stimulus instead of collinear with it. Other perceptual grouping effects reveal illusory contours that exhibit a sharp corner or vertex, and still others take the form of vertices defined by the intersection of three, four, or more illusory contours that meet at a point. A direct extension of the collinear completion models to account for these phenomena tends towards a combinatorial explosion, because it would suggest cells with specialized receptive fields configured to perform each of those completion types, each of which would have to be replicated at every location and every orientation across the visual field. These phenomena therefore challenge the adequacy of the neural network approach to account for these diverse perceptual phenomena. I have proposed elsewhere an alternative paradigm of neurocomputation in the harmonic resonance theory (Lehar 1999, see website), whereby pattern recognition and completion are performed by spatial standing waves across the neural substrate. The standing waves perform a computational function analogous to that of the spatial receptive fields of the neural network approach, except that, unlike that paradigm, a single resonance mechanism performs a function equivalent to a whole array of spatial receptive fields of different spatial configurations and of different orientations

  6. Knowledge does not protect against illusory truth.

    PubMed

    Fazio, Lisa K; Brashier, Nadia M; Payne, B Keith; Marsh, Elizabeth J

    2015-10-01

    In daily life, we frequently encounter false claims in the form of consumer advertisements, political propaganda, and rumors. Repetition may be one way that insidious misconceptions, such as the belief that vitamin C prevents the common cold, enter our knowledge base. Research on the illusory truth effect demonstrates that repeated statements are easier to process, and subsequently perceived to be more truthful, than new statements. The prevailing assumption in the literature has been that knowledge constrains this effect (i.e., repeating the statement "The Atlantic Ocean is the largest ocean on Earth" will not make you believe it). We tested this assumption using both normed estimates of knowledge and individuals' demonstrated knowledge on a postexperimental knowledge check (Experiment 1). Contrary to prior suppositions, illusory truth effects occurred even when participants knew better. Multinomial modeling demonstrated that participants sometimes rely on fluency even if knowledge is also available to them (Experiment 2). Thus, participants demonstrated knowledge neglect, or the failure to rely on stored knowledge, in the face of fluent processing experiences. (c) 2015 APA, all rights reserved).

  7. Tactile functions after cerebral hemispherectomy.

    PubMed

    Backlund, H; Morin, C; Ptito, A; Bushnell, M C; Olausson, H

    2005-01-01

    Patients that were hemispherectomized due to brain lesions early in life sometimes have remarkably well-preserved tactile functions on their paretic body half. This has been attributed to developmental neuroplasticity. However, the tactile examinations generally have been fairly crude, and subtle deficits may not have been revealed. We investigated monofilament detection and three types of tactile directional sensibility in four hemispherectomized patients and six healthy controls. Patients were examined bilaterally on the face, forearm and lower leg. Normal subjects were examined unilaterally. Following each test of directional sensibility, subjects were asked to rate the intensity of the stimulation. On the nonparetic side, results were almost always in the normal range. On the paretic side, the patients' capacity for monofilament detection was less impaired than their directional sensibility. Despite the disturbed directional sensibility on their paretic side the patients rated tactile sensations evoked by the stimuli, on both their paretic and nonparetic body halves, as more intense than normals. Thus, mechanisms of plasticity seem adequate for tactile detection and intensity coding but not for more complex tactile functions such as directional sensibility. The reason for the high vulnerability of tactile directional sensibility may be that it depends on spatially and temporally precise afferent information processed in a distributed cortical network.

  8. Recent Progress in Technologies for Tactile Sensors

    PubMed Central

    Sun, Xuguang; Xue, Ning; Li, Tong; Liu, Chang

    2018-01-01

    Over the last two decades, considerable scientific and technological efforts have been devoted to developing tactile sensing based on a variety of transducing mechanisms, with prospective applications in many fields such as human–machine interaction, intelligent robot tactile control and feedback, and tactile sensorized minimally invasive surgery. This paper starts with an introduction of human tactile systems, followed by a presentation of the basic demands of tactile sensors. State-of-the-art tactile sensors are reviewed in terms of their diverse sensing mechanisms, design consideration, and material selection. Subsequently, typical performances of the sensors, along with their advantages and disadvantages, are compared and analyzed. Two major potential applications of tactile sensing systems are discussed in detail. Lastly, we propose prospective research directions and market trends of tactile sensing systems. PMID:29565835

  9. Recent Progress in Technologies for Tactile Sensors.

    PubMed

    Chi, Cheng; Sun, Xuguang; Xue, Ning; Li, Tong; Liu, Chang

    2018-03-22

    Over the last two decades, considerable scientific and technological efforts have been devoted to developing tactile sensing based on a variety of transducing mechanisms, with prospective applications in many fields such as human-machine interaction, intelligent robot tactile control and feedback, and tactile sensorized minimally invasive surgery. This paper starts with an introduction of human tactile systems, followed by a presentation of the basic demands of tactile sensors. State-of-the-art tactile sensors are reviewed in terms of their diverse sensing mechanisms, design consideration, and material selection. Subsequently, typical performances of the sensors, along with their advantages and disadvantages, are compared and analyzed. Two major potential applications of tactile sensing systems are discussed in detail. Lastly, we propose prospective research directions and market trends of tactile sensing systems.

  10. Tactile modulation of hippocampal place fields.

    PubMed

    Gener, Thomas; Perez-Mendez, Lorena; Sanchez-Vives, Maria V

    2013-12-01

    Neural correlates of spatial representation can be found in the activity of the hippocampal place cells. These neurons are characterized by firing whenever the animal is located in a particular area of the space, the place field. Place fields are modulated by sensory cues, such as visual, auditory, or olfactory cues, being the influence of visual inputs the most thoroughly studied. Tactile information gathered by the whiskers has a prominent representation in the rat cerebral cortex. However, the influence of whisker-detected tactile cues on place fields remains an open question. Here we studied place fields in an enriched tactile environment where the remaining sensory cues were occluded. First, place cells were recorded before and after blockade of tactile transmission by means of lidocaine applied on the whisker pad. Following tactile deprivation, the majority of place cells decreased their firing rate and their place fields expanded. We next rotated the tactile cues and 90% of place fields rotated with them. Our results demonstrate that tactile information is integrated into place cells at least in a tactile-enriched arena and when other sensory cues are not available. Copyright © 2013 Wiley Periodicals, Inc.

  11. Illusory Distance Modulates Perceived Size of Afterimage despite the Disappearance of Depth Cues

    PubMed Central

    Liu, Shengxi; Lei, Quan

    2016-01-01

    It is known that the perceived size of an afterimage is modulated by the perceived distance between the observer and the depth plane on which the afterimage is projected (Emmert’s law). Illusions like Ponzo demonstrate that illusory distance induced by depth cues can also affect the perceived size of an object. In this study, we report that the illusory distance not only modulates the perceived size of object’s afterimage during the presence of the depth cues, but the modulation persists after the disappearance of the depth cues. We used an adapted version of the classic Ponzo illusion. Illusory depth perception was induced by linear perspective cues with two tilted lines converging at the upper boundary of the display. Two horizontal bars were placed between the two lines, resulting in a percept of the upper bar to be farther away than the lower bar. Observers were instructed to make judgment about the relative size of the afterimage of the lower and the upper bars after adaptation. When the perspective cues and the bars were static, the illusory effect of the Ponzo afterimage is consistent with that of the traditional size-distance illusion. When the perspective cues were flickering and the bars were static, only the afterimage of the latter was perceived, yet still a considerable amount of the illusory effect was perceived. The results could not be explained by memory of a prejudgment of the bar length during the adaptation phase. The findings suggest that cooccurrences of depth cues and object may link a depth marker for the object, so that the perceived size of the object or its afterimage is modulated by feedback of depth information from higher-level visual cortex even when there is no depth cues directly available on the retinal level. PMID:27391335

  12. Optical-to-Tactile Translator

    NASA Technical Reports Server (NTRS)

    Langevin, Maurice L. (Inventor); Moynihan, Philip I. (Inventor)

    2000-01-01

    An optical-to-tactile translator provides an aid for the visually impaired by translating a near-field scene to a tactile signal corresponding to said near-field scene. An optical sensor using a plurality of active pixel sensors (APS) converts the optical image within the near-field scene to a digital signal. The digital signal is then processed by a microprocessor and a simple shape signal is generated based on the digital signal. The shape signal is then communicated to a tactile transmitter where the shape signal is converted into a tactile signal using a series of contacts. The shape signal may be an outline of the significant shapes determined in the near-field scene, or the shape signal may comprise a simple symbolic representation of common items encountered repeatedly. The user is thus made aware of the unseen near-field scene, including potential obstacles and dangers, through a series of tactile contacts. In a preferred embodiment, a range determining device such as those commonly found on auto-focusing cameras is included to limit the distance that the optical sensor interprets the near-field scene.

  13. Blind Braille readers mislocate tactile stimuli.

    PubMed

    Sterr, Annette; Green, Lisa; Elbert, Thomas

    2003-05-01

    In a previous experiment, we observed that blind Braille readers produce errors when asked to identify on which finger of one hand a light tactile stimulus had occurred. With the present study, we aimed to specify the characteristics of this perceptual error in blind and sighted participants. The experiment confirmed that blind Braille readers mislocalised tactile stimuli more often than sighted controls, and that the localisation errors occurred significantly more often at the right reading hand than at the non-reading hand. Most importantly, we discovered that the reading fingers showed the smallest error frequency, but the highest rate of stimulus attribution. The dissociation of perceiving and locating tactile stimuli in the blind suggests altered tactile information processing. Neuroplasticity, changes in tactile attention mechanisms as well as the idea that blind persons may employ different strategies for tactile exploration and object localisation are discussed as possible explanations for the results obtained.

  14. Influences of Age and Emotion on Source Guessing: Are Older Adults More Likely to Show Fear-Relevant Illusory Correlations?

    PubMed

    Meyer, Miriam Magdalena; Buchner, Axel; Bell, Raoul

    2016-09-01

    The present study investigates age differences in the vulnerability to illusory correlations between fear-relevant stimuli and threatening information. Younger and older adults saw pictures of threatening snakes and nonthreatening fish, paired with threatening and nonthreatening context information ("poisonous" and "nonpoisonous") with a null contingency between animal type and poisonousness. In a source monitoring test, participants were required to remember whether an animal was associated with poisonousness or nonpoisonousness. Illusory correlations were implicitly measured via a multinomial model. One advantage of this approach is that memory and guessing processes can be assessed independently. An illusory correlation would be reflected in a higher probability of guessing that a snake rather than a fish was poisonous if the poisonousness of the animal was not remembered. Older adults showed evidence of illusory correlations in source guessing while younger adults did not; instead they showed evidence of probability matching. Moreover, snake fear was associated with increased vulnerability to illusory correlations in older adults. The findings confirm that older adults are more susceptible to fear-relevant illusory correlations than younger adults. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Behavioral analysis of preterm neonates included in a tactile and kinesthetic stimulation program during hospitalization.

    PubMed

    Ferreira, Andréia M; Bergamasco, Niélsy H P

    2010-01-01

    To evaluate the effect of tactile and kinesthetic stimulation on behavioral and clinical development in preterm neonates while still in the hospital. Thirty-two clinically stable preterm infants weighing <2.500 grams, with no significant perinatal asphyxia, were allocated to two groups: a control group (CG) in which no intervention was made (n=16) and a study group (SG) in which the newborn infants received tactile and kinesthetic stimulation (n=16). Data on the infants' clinical progress were collected from medical charts and behavioral evaluations by means of a series of weekly, eight-minute films recorded from the time of inclusion into the study until hospital discharge. There was a trend towards a shorter duration of hospital stay, increased daily weight gain and a predominance of self-regulated behavior (regular breathing, state of alertness, balanced tonus, a range of postures, coordinated movements, hand-to-face movement control, suction, grip, support) in infants in the SG. With respect to motor control, comparative analysis of postconceptional ages according to age-bracket (I - 31-33 weeks 6/7; II - 34-36 weeks 6/7; and III - 37-39 weeks 6/7) revealed balanced tonus and coordinated voluntary movements in all three periods, a longer time spent in a range of postures (age bracket I) or in flexion (age bracket II) and more regular breathing in age bracket I in the SG. In the hospital, tactile and kinesthetic stimulation was shown to have a positive effect, contributing towards adjustment and self-regulation of behavior in the preterm newborn infant. Article registered in the Australian New Zealand Clinical Trials Registry (ANZCTR) under the number ACTRN12610000133033.

  16. Slanted joint axes of the stick insect antenna: an adaptation to tactile acuity

    NASA Astrophysics Data System (ADS)

    Mujagic, Samir; Krause, André F.; Dürr, Volker

    2007-04-01

    Like many flightless, obligatory walking insects, the stick insect Carausius morosus makes intensive use of active antennal movements for tactile near range exploration and orientation. The antennal joints of C. morosus have a peculiar oblique and non-orthogonal joint axis arrangement. Moreover, this arrangement is known to differ from that in crickets (Ensifera), locusts (Caelifera) and cockroaches (Blattodea), all of which have an orthogonal joint axis arrangement. Our hypothesis was that the situation found in C. morosus represents an important evolutionary trait of the order of stick and leaf insects (Phasmatodea). If this was true, it should be common to other species of the Phasmatodea. The objective of this comparative study was to resolve this question. We have measured the joint axis orientation of the head scape and scape pedicel joints along with other parameters that affect the tactile efficiency of the antenna. The obtained result was a complete kinematic description of the antenna. This was used to determine the size and location of kinematic out-of-reach zones, which are indicators of tactile acuity. We show that the oblique and non-orthogonal arrangement is common to eight species from six sub-families indicating that it is a synapomorphic character of the Euphasmatodea. This character can improve tactile acuity compared to the situation in crickets, locusts and cockroaches. Finally, because molecular data of a recent study indicate that the Phasmatodea may have evolved as flightless, obligatory walkers, we argue that the antennal joint axis arrangement of the Euphasmatodea reflects an evolutionary adaptation to tactile near range exploration during terrestrial locomotion.

  17. Saccades to remembered targets: the effects of smooth pursuit and illusory stimulus motion

    NASA Technical Reports Server (NTRS)

    Zivotofsky, A. Z.; Rottach, K. G.; Averbuch-Heller, L.; Kori, A. A.; Thomas, C. W.; Dell'Osso, L. F.; Leigh, R. J.

    1996-01-01

    error was greater than under any other experimental condition. 6. In most trials, the initial saccade to the remembered target was followed by additional saccades while the subject was still in darkness. These secondary saccades, which were executed in the absence of visual feedback, brought the eye closer to the target location. During paradigms involving horizontal background movement, these corrections were more prominent horizontally than vertically. 7. Further measurements were made in two subjects to determine whether inaccuracy of memory-guided saccades, in the horizontal plane, was due to mislocalization at the time that the target flashed, misrepresentation of the trajectory of the pursuit eye movement during the memory period, or both. 8. The magnitude of the saccadic error, both with and without corrections made in darkness, was mislocalized by approximately 30% of the displacement of the background at the time that the target flashed. The magnitude of the saccadic error also was influenced by net movement of the background during the memory period, corresponding to approximately 25% of net background movement for the initial saccade and approximately 13% for the final eye position achieved in darkness. 9. We formulated simple linear models to test specific hypotheses about which combinations of signals best describe the observed saccadic amplitudes. We tested the possibilities that the brain made an accurate memory of target location and a reliable representation of the eye movement during the memory period, or that one or both of these was corrupted by the illusory visual stimulus. Our data were best accounted for by a model in which both the working memory of target location and the internal representation of the horizontal eye movements were corrupted by the illusory visual stimulus. We conclude that extraretinal signals played only a minor role, in comparison with visual estimates of the direction of gaze, in planning eye movements to remembered targ.

  18. Auditory-tactile echo-reverberating stuttering speech corrector

    NASA Astrophysics Data System (ADS)

    Kuniszyk-Jozkowiak, Wieslawa; Adamczyk, Bogdan

    1997-02-01

    The work presents the construction of a device, which transforms speech sounds into acoustical and tactile signals of echo and reverberation. Research has been done on the influence of the echo and reverberation, which are transmitted as acoustic and tactile stimuli, on speech fluency. Introducing the echo or reverberation into the auditory feedback circuit results in a reduction of stuttering. A bit less, but still significant corrective effects are observed while using the tactile channel for transmitting the signals. The use of joined auditory and tactile channels increases the effects of their corrective influence on the stutterers' speech. The results of the experiment justify the use of the tactile channel in the stutterers' therapy.

  19. Differentiation of Illusory and True Halo in Writing Scores

    ERIC Educational Resources Information Center

    Lai, Emily R.; Wolfe, Edward W.; Vickers, Daisy

    2015-01-01

    This report summarizes an empirical study that addresses two related topics within the context of writing assessment--illusory halo and how much unique information is provided by multiple analytic scores. Specifically, we address the issue of whether unique information is provided by analytic scores assigned to student writing, beyond what is…

  20. Disrupted integration of sensory stimuli with information about the movement of the body as a mechanism explaining LSD-induced experience.

    PubMed

    Juszczak, Grzegorz R

    2017-03-01

    LSD (lysergic acid diethylamide) is a model psychedelic drug used to study mechanism underlying the effects induced by hallucinogens. However, despite advanced knowledge about molecular mechanism responsible for the effects induced by LSD and other related substances acting at serotonergic 5-HT 2a receptors, we still do not understand how these drugs trigger specific sensory experiences. LSD-induced experience is characterised by perception of movement in the environment and by presence of various bodily sensations such as floating in space, merging into surroundings and movement out of the physical body (the out-of-body experience). It means that a large part of the experience induced by the LSD can be simplified to the illusory movement that can be attributed to the self or to external objects. The phenomenology of the LSD-induced experience has been combined with the fact that serotonergic neurons provide all major parts of the brain with information about the level of tonic motor activity, occurrence of external stimuli and the execution of orienting responses. Therefore, it has been proposed that LSD-induced stimulation of 5-HT 2a receptors disrupts the integration of the sensory stimuli with information about the movement of the body leading to perception of illusory movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Illusory conjunctions of pitch and duration in unfamiliar tone sequences.

    PubMed

    Thompson, W F; Hall, M D; Pressing, J

    2001-02-01

    In 3 experiments, the authors examined short-term memory for pitch and duration in unfamiliar tone sequences. Participants were presented a target sequence consisting of 2 tones (Experiment 1) or 7 tones (Experiments 2 and 3) and then a probe tone. Participants indicated whether the probe tone matched 1 of the target tones in both pitch and duration. Error rates were relatively low if the probe tone matched 1 of the target tones or if it differed from target tones in pitch, duration, or both. Error rates were remarkably high, however, if the probe tone combined the pitch of 1 target tone with the duration of a different target tone. The results suggest that illusory conjunctions of these dimensions frequently occur. A mathematical model is presented that accounts for the relative contribution of pitch errors, duration errors, and illusory conjunctions of pitch and duration.

  2. Virtual environment tactile system

    DOEpatents

    Renzi, Ronald

    1996-01-01

    A method for providing a realistic sense of touch in virtual reality by means of programmable actuator assemblies is disclosed. Each tactile actuator assembly consists of a number of individual actuators whose movement is controlled by a computer and associated drive electronics. When an actuator is energized, the rare earth magnet and the associated contactor, incorporated within the actuator, are set in motion by the opposing electromagnetic field of a surrounding coil. The magnet pushes the contactor forward to contact the skin resulting in the sensation of touch. When the electromagnetic field is turned off, the rare earth magnet and the contactor return to their neutral positions due to the magnetic equilibrium caused by the interaction with the ferrous outer sleeve. The small size and flexible nature of the actuator assemblies permit incorporation into a glove, boot or body suit. The actuator has additional applications, such as, for example, as an accelerometer, an actuator for precisely controlled actuations or to simulate the sensation of braille letters.

  3. Displacement of location in illusory line motion.

    PubMed

    Hubbard, Timothy L; Ruppel, Susan E

    2013-05-01

    Six experiments examined displacement in memory for the location of the line in illusory line motion (ILM; appearance or disappearance of a stationary cue is followed by appearance of a stationary line that is presented all at once, but the stationary line is perceived to "unfold" or "be drawn" from the end closest to the cue to the end most distant from the cue). If ILM was induced by having a single cue appear, then memory for the location of the line was displaced toward the cue, and displacement was larger if the line was closer to the cue. If ILM was induced by having one of two previously visible cues vanish, then memory for the location of the line was displaced away from the cue that vanished. In general, the magnitude of displacement increased and then decreased as retention interval increased from 50 to 250 ms and from 250 to 450 ms, respectively. Displacement of the line (a) is consistent with a combination of a spatial averaging of the locations of the cue and the line with a relatively weaker dynamic in the direction of illusory motion, (b) might be implemented in a spreading activation network similar to networks previously suggested to implement displacement resulting from implied or apparent motion, and (c) provides constraints and challenges for theories of ILM.

  4. Alternative mode of presentation of Kanizsa figures sheds new light on the chronometry of the mechanisms underlying the perception of illusory figures.

    PubMed

    Brodeur, M; Lepore, F; Lepage, M; Bacon, B A; Jemel, B; Debruille, J B

    2008-01-31

    The mechanisms responsible for the perception of illusory modal figures are usually studied by presenting entire Kanizsa figures at stimulus onset. However, with this mode of presentation, the brain activity generated by the inducers (the 'pacmen') is difficult to differentiate from the activity underlying the perception of the illusory figure. Therefore, in addition to this usual presentation mode, we used an alternative presentation mode. Inducer disks remained permanently on the screen and the illusory figure was induced by just removing the notches from the disks. The results support the heuristic value of this alternative mode of presentation. The P1 deflection of the visual evoked potentials (VEPs) was found to be greater for the illusory modal figure than for its control and for an amodal figure. This modulation is one of the earliest direct evidences for a low-level processing of illusory forms in the human brain. Meanwhile, larger N1s were obtained for the control figures than for the illusory figures in the notch mode of presentation. While this new type of N1 modulation could shed some light on the stage of processing indexed by this deflection, several propositions are put forward to account for the P1 and N1 variations found.

  5. Exploration of the Effectiveness of Tactile Methods

    ERIC Educational Resources Information Center

    Aldajani, Neda F.

    2016-01-01

    This paper introduces the tactile method and aims to explore the effectiveness of using tactile methods with students who are blind and visually impaired. Although there was limited research about using this strategy, all of the research agrees that using tactile is one of the best ways for students who are blind and visually impaired to be…

  6. Evidence against the temporal subsampling account of illusory motion reversal

    PubMed Central

    Kline, Keith A.; Eagleman, David M.

    2010-01-01

    An illusion of reversed motion may occur sporadically while viewing continuous smooth motion. This has been suggested as evidence of discrete temporal sampling by the visual system in analogy to the sampling that generates the wagon–wheel effect on film. In an alternative theory, the illusion is not the result of discrete sampling but instead of perceptual rivalry between appropriately activated and spuriously activated motion detectors. Results of the current study demonstrate that illusory reversals of two spatially overlapping and orthogonal motions often occur separately, providing evidence against the possibility that illusory motion reversal (IMR) is caused by temporal sampling within a visual region. Further, we find that IMR occurs with non-uniform and non-periodic stimuli—an observation that is not accounted for by the temporal sampling hypothesis. We propose, that a motion aftereffect is superimposed on the moving stimulus, sporadically allowing motion detectors for the reverse direction to dominate perception. PMID:18484852

  7. Presentation of words to separate hemispheres prevents interword illusory conjunctions.

    PubMed

    Liederman, J; Sohn, Y S

    1999-03-01

    We tested the hypothesis that division of inputs between the hemispheres could prevent interword letter migrations in the form of illusory conjunctions. The task was to decide whether a centrally-presented consonant-vowel-consonant (CVC) target word matched one of four CVC words presented to a single hemisphere or divided between the hemispheres in a subsequent test display. During half of the target-absent trials, known as conjunction trials, letters from two separate words (e.g., "tag" and "cop") in the test display could be mistaken for a target word (e.g., "top"). For the other half of the target-absent trails, the test display did not match any target consonants (Experiment 1, N = 16) or it matched one target consonant (Experiment 2, N = 29), the latter constituting true "feature" trials. Bi- as compared to unihemispheric presentation significantly reduced the number of conjunction, but not feature, errors. Illusory conjunctions did not occur when the words were presented to separate hemispheres.

  8. Eye movement instructions modulate motion illusion and body sway with Op Art

    PubMed Central

    Kapoula, Zoï; Lang, Alexandre; Vernet, Marine; Locher, Paul

    2015-01-01

    Op Art generates illusory visual motion. It has been proposed that eye movements participate in such illusion. This study examined the effect of eye movement instructions (fixation vs. free exploration) on the sensation of motion as well as the body sway of subjects viewing Op Art paintings. Twenty-eight healthy adults in orthostatic stance were successively exposed to three visual stimuli consisting of one figure representing a cross (baseline condition) and two Op Art paintings providing sense of motion in depth—Bridget Riley’s Movements in Squares and Akiyoshi Kitaoka’s Rollers. Before their exposure to the Op Art images, participants were instructed either to fixate at the center of the image (fixation condition) or to explore the artwork (free viewing condition). Posture was measured for 30 s per condition using a body fixed sensor (accelerometer). The major finding of this study is that the two Op Art paintings induced a larger antero-posterior body sway both in terms of speed and displacement and an increased motion illusion in the free viewing condition as compared to the fixation condition. For body sway, this effect was significant for the Riley painting, while for motion illusion this effect was significant for Kitaoka’s image. These results are attributed to macro-saccades presumably occurring under free viewing instructions, and most likely to the small vergence drifts during fixations following the saccades; such movements in interaction with visual properties of each image would increase either the illusory motion sensation or the antero-posterior body sway. PMID:25859197

  9. Eye movement instructions modulate motion illusion and body sway with Op Art.

    PubMed

    Kapoula, Zoï; Lang, Alexandre; Vernet, Marine; Locher, Paul

    2015-01-01

    Op Art generates illusory visual motion. It has been proposed that eye movements participate in such illusion. This study examined the effect of eye movement instructions (fixation vs. free exploration) on the sensation of motion as well as the body sway of subjects viewing Op Art paintings. Twenty-eight healthy adults in orthostatic stance were successively exposed to three visual stimuli consisting of one figure representing a cross (baseline condition) and two Op Art paintings providing sense of motion in depth-Bridget Riley's Movements in Squares and Akiyoshi Kitaoka's Rollers. Before their exposure to the Op Art images, participants were instructed either to fixate at the center of the image (fixation condition) or to explore the artwork (free viewing condition). Posture was measured for 30 s per condition using a body fixed sensor (accelerometer). The major finding of this study is that the two Op Art paintings induced a larger antero-posterior body sway both in terms of speed and displacement and an increased motion illusion in the free viewing condition as compared to the fixation condition. For body sway, this effect was significant for the Riley painting, while for motion illusion this effect was significant for Kitaoka's image. These results are attributed to macro-saccades presumably occurring under free viewing instructions, and most likely to the small vergence drifts during fixations following the saccades; such movements in interaction with visual properties of each image would increase either the illusory motion sensation or the antero-posterior body sway.

  10. Fingertip-shaped optical tactile sensor for robotic applications

    NASA Technical Reports Server (NTRS)

    Begej, Stefan

    1988-01-01

    Progress is described regarding the development of a high-density, fiber-optic, fingertip-shaped tactile sensor specifically designed for application to dexterous robotics. The sensor operates on optical principles involving the frustration of total internal reflection at a waveguide/elastomer interface and generates a grey-scale tactile image that represents the normal forces of contact. The sensor contains 256 taxels (sensing sites) distributed in a dual-density pattern that includes a tactile fovea near the tip which measures 13 mm x 13 mm and contains 169 taxels. The details regarding the design and construction of this tactile sensor are presented, in addition to photographs of tactile imprints.

  11. Summary of Tactile User Interfaces Techniques and Systems

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly

    2005-01-01

    Mental workload can be de.ned as the ratio of demand to allocated resources. Multiple-resource theory stresses the importance of distribution of tasks and information across various human sensory channels to reduce mental workload. One sensory channel that has been of interest since the late 1800s is touch. Unlike the more typical displays that target vision or hearing, tactile displays present information to the user s sense of touch. We present a summary of different methods for tactile display, historic and more recent systems that incorporate tactile display for information presentation, advantages and disadvantages of targeting the tactile channel, and future directions in tactile display research.

  12. Summary of Tactile User Interfaces Techniques and Systems

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly

    2004-01-01

    Mental workload can be defined as the ratio of demand to allocated resources. Multiple- resource theory stresses the importance of distribution of tasks and information across various sensory channels of the human to reduce mental workload. One sensory channel that has been of interest since the late 1800s is touch. Unlike the more typical displays that target vision or hearing, tactile displays present information to the user s sense of touch. We present a summary of different methods for tactile display; historic and more recent systems that incorporate tactile display for information presentation; advantages and disadvantages of targeting the tactile channel; and future directions in tactile display research.

  13. A Tactile Carina Nebula

    NASA Astrophysics Data System (ADS)

    Grice, Noreen A.; Mutchler, M.

    2010-01-01

    Astronomy was once considered a science restricted to fully sighted participants. But in the past two decades, accessible books with large print/Braille and touchable pictures have brought astronomy and space science to the hands and mind's eye of students, regardless of their visual ability. A new universally-designed tactile image featuring the Hubble mosaic of the Carina Nebula is being presented at this conference. The original dataset was obtained with Hubble's Advanced Camera for Surveys (ACS) hydrogen-alpha filter in 2005. It became an instant icon after being infused with additional color information from ground-based CTIO data, and released as Hubble's 17th anniversary image. Our tactile Carina Nebula promotes multi-mode learning about the entire life-cycle of stars, which is dramatically illustrated in this Hubble mosaic. When combined with descriptive text in print and Braille, the visual and tactile components seamlessly reach both sighted and blind populations. Specific touchable features of the tactile image identify the shapes and orientations of objects in the Carina Nebula that include star-forming regions, jets, pillars, dark and light globules, star clusters, shocks/bubbles, the Keyhole Nebula, and stellar death (Eta Carinae). Visit our poster paper to touch the Carina Nebula!

  14. Encoding of Tactile Stimuli by Mechanoreceptors and Interneurons of the Medicinal Leech

    PubMed Central

    Kretzberg, Jutta; Pirschel, Friederice; Fathiazar, Elham; Hilgen, Gerrit

    2016-01-01

    For many animals processing of tactile information is a crucial task in behavioral contexts like exploration, foraging, and stimulus avoidance. The leech, having infrequent access to food, developed an energy efficient reaction to tactile stimuli, avoiding unnecessary muscle movements: The local bend behavior moves only a small part of the body wall away from an object touching the skin, while the rest of the animal remains stationary. Amazingly, the precision of this localized behavioral response is similar to the spatial discrimination threshold of the human fingertip, although the leech skin is innervated by an order of magnitude fewer mechanoreceptors and each midbody ganglion contains only 400 individually identified neurons in total. Prior studies suggested that this behavior is controlled by a three-layered feed-forward network, consisting of four mechanoreceptors (P cells), approximately 20 interneurons and 10 individually characterized motor neurons, all of which encode tactile stimulus location by overlapping, symmetrical tuning curves. Additionally, encoding of mechanical force was attributed to three types of mechanoreceptors reacting to distinct intensity ranges: T cells for touch, P cells for pressure, and N cells for strong, noxious skin stimulation. In this study, we provide evidences that tactile stimulus encoding in the leech is more complex than previously thought. Combined electrophysiological, anatomical, and voltage sensitive dye approaches indicate that P and T cells both play a major role in tactile information processing resulting in local bending. Our results indicate that tactile encoding neither relies on distinct force intensity ranges of different cell types, nor location encoding is restricted to spike count tuning. Instead, we propose that P and T cells form a mixed type population, which simultaneously employs temporal response features and spike counts for multiplexed encoding of touch location and force intensity. This hypothesis

  15. Optic flow improves adaptability of spatiotemporal characteristics during split-belt locomotor adaptation with tactile stimulation

    PubMed Central

    Anthony Eikema, Diderik Jan A.; Chien, Jung Hung; Stergiou, Nicholas; Myers, Sara A.; Scott-Pandorf, Melissa M.; Bloomberg, Jacob J.; Mukherjee, Mukul

    2015-01-01

    Human locomotor adaptation requires feedback and feed-forward control processes to maintain an appropriate walking pattern. Adaptation may require the use of visual and proprioceptive input to decode altered movement dynamics and generate an appropriate response. After a person transfers from an extreme sensory environment and back, as astronauts do when they return from spaceflight, the prolonged period required for re-adaptation can pose a significant burden. In our previous paper, we showed that plantar tactile vibration during a split-belt adaptation task did not interfere with the treadmill adaptation however, larger overground transfer effects with a slower decay resulted. Such effects, in the absence of visual feedback (of motion) and perturbation of tactile feedback, is believed to be due to a higher proprioceptive gain because, in the absence of relevant external dynamic cues such as optic flow, reliance on body-based cues is enhanced during gait tasks through multisensory integration. In this study we therefore investigated the effect of optic flow on tactile stimulated split-belt adaptation as a paradigm to facilitate the sensorimotor adaptation process. Twenty healthy young adults, separated into two matched groups, participated in the study. All participants performed an overground walking trial followed by a split-belt treadmill adaptation protocol. The tactile group (TC) received vibratory plantar tactile stimulation only, whereas the virtual reality and tactile group (VRT) received an additional concurrent visual stimulation: a moving virtual corridor, inducing perceived self-motion. A post-treadmill overground trial was performed to determine adaptation transfer. Interlimb coordination of spatiotemporal and kinetic variables was quantified using symmetry indices, and analyzed using repeated-measures ANOVA. Marked changes of step length characteristics were observed in both groups during split-belt adaptation. Stance and swing time symmetry were

  16. Tactile communication.

    DOT National Transportation Integrated Search

    1962-05-01

    Tactile communication presents a relatively unexploited channel of information transmission in the field of aviation. Visual and auditory input channels frequently reach an information saturation point during various flight operations. A cutaneous co...

  17. Viewing the body modulates tactile receptive fields.

    PubMed

    Haggard, Patrick; Christakou, Anastasia; Serino, Andrea

    2007-06-01

    Tactile discrimination performance depends on the receptive field (RF) size of somatosensory cortical (SI) neurons. Psychophysical masking effects can reveal the RF of an idealized "virtual" somatosensory neuron. Previous studies show that top-down factors strongly affect tactile discrimination performance. Here, we show that non-informative vision of the touched body part influences tactile discrimination by modulating tactile RFs. Ten subjects performed spatial discrimination between touch locations on the forearm. Performance was improved when subjects saw their forearm compared to viewing a neutral object in the same location. The extent of visual information was relevant, since restricted view of the forearm did not have this enhancing effect. Vibrotactile maskers were placed symmetrically on either side of the tactile target locations, at two different distances. Overall, masking significantly impaired discrimination performance, but the spatial gradient of masking depended on what subjects viewed. Viewing the body reduced the effect of distant maskers, but enhanced the effect of close maskers, as compared to viewing a neutral object. We propose that viewing the body improves functional touch by sharpening tactile RFs in an early somatosensory map. Top-down modulation of lateral inhibition could underlie these effects.

  18. Tactility and the body in early Chinese medicine.

    PubMed

    Hsu, Elisabeth

    2005-03-01

    If visual inspection of corpses was central to the development of anatomy in modern Europe, one may ask which of the senses was important for the emergence of the predominant currents of scholarly medical knowledge and practice in third- and second-century B.C.E. China? This article argues that it was tactile perception prompted by a tactile exploration of living bodies. The evidence, derived from a close reading of the Mawangdui medical manuscripts, the 105th chapter of the Records of the Historian, and selected passages from the Huang Di's Inner Canon, points to three important trends: first, the tactile exploration of the extremities led to a rich vocabulary of compound words for pain as localized in specific body parts; second, the tactile exploration of the mai gave rise to an even richer vocabulary on qualities of touch in pulse diagnostics; and third, the tactile exploration of the abdomen led to the assessment of the quality of the internal viscera with words that generally were used for describing the tactile quality of skin and flesh. This finding may appear surprising in the light of later developments during the dynastic history of Chinese medicine where tactile exploration of abdomen and extremities would appear unseemly. The author suggests that extensive tactile explorations of the body were possible before Confucius' teachings became a predominant aspect of state ideology.

  19. Learning tactile skills through curious exploration

    PubMed Central

    Pape, Leo; Oddo, Calogero M.; Controzzi, Marco; Cipriani, Christian; Förster, Alexander; Carrozza, Maria C.; Schmidhuber, Jürgen

    2012-01-01

    We present curiosity-driven, autonomous acquisition of tactile exploratory skills on a biomimetic robot finger equipped with an array of microelectromechanical touch sensors. Instead of building tailored algorithms for solving a specific tactile task, we employ a more general curiosity-driven reinforcement learning approach that autonomously learns a set of motor skills in absence of an explicit teacher signal. In this approach, the acquisition of skills is driven by the information content of the sensory input signals relative to a learner that aims at representing sensory inputs using fewer and fewer computational resources. We show that, from initially random exploration of its environment, the robotic system autonomously develops a small set of basic motor skills that lead to different kinds of tactile input. Next, the system learns how to exploit the learned motor skills to solve supervised texture classification tasks. Our approach demonstrates the feasibility of autonomous acquisition of tactile skills on physical robotic platforms through curiosity-driven reinforcement learning, overcomes typical difficulties of engineered solutions for active tactile exploration and underactuated control, and provides a basis for studying developmental learning through intrinsic motivation in robots. PMID:22837748

  20. Assimilation of virtual legs and perception of floor texture by complete paraplegic patients receiving artificial tactile feedback.

    PubMed

    Shokur, Solaiman; Gallo, Simone; Moioli, Renan C; Donati, Ana Rita C; Morya, Edgard; Bleuler, Hannes; Nicolelis, Miguel A L

    2016-09-19

    Spinal cord injuries disrupt bidirectional communication between the patient's brain and body. Here, we demonstrate a new approach for reproducing lower limb somatosensory feedback in paraplegics by remapping missing leg/foot tactile sensations onto the skin of patients' forearms. A portable haptic display was tested in eight patients in a setup where the lower limbs were simulated using immersive virtual reality (VR). For six out of eight patients, the haptic display induced the realistic illusion of walking on three different types of floor surfaces: beach sand, a paved street or grass. Additionally, patients experienced the movements of the virtual legs during the swing phase or the sensation of the foot rolling on the floor while walking. Relying solely on this tactile feedback, patients reported the position of the avatar leg during virtual walking. Crossmodal interference between vision of the virtual legs and tactile feedback revealed that patients assimilated the virtual lower limbs as if they were their own legs. We propose that the addition of tactile feedback to neuroprosthetic devices is essential to restore a full lower limb perceptual experience in spinal cord injury (SCI) patients, and will ultimately, lead to a higher rate of prosthetic acceptance/use and a better level of motor proficiency.

  1. Assimilation of virtual legs and perception of floor texture by complete paraplegic patients receiving artificial tactile feedback

    PubMed Central

    Shokur, Solaiman; Gallo, Simone; Moioli, Renan C.; Donati, Ana Rita C.; Morya, Edgard; Bleuler, Hannes; Nicolelis, Miguel A.L.

    2016-01-01

    Spinal cord injuries disrupt bidirectional communication between the patient’s brain and body. Here, we demonstrate a new approach for reproducing lower limb somatosensory feedback in paraplegics by remapping missing leg/foot tactile sensations onto the skin of patients’ forearms. A portable haptic display was tested in eight patients in a setup where the lower limbs were simulated using immersive virtual reality (VR). For six out of eight patients, the haptic display induced the realistic illusion of walking on three different types of floor surfaces: beach sand, a paved street or grass. Additionally, patients experienced the movements of the virtual legs during the swing phase or the sensation of the foot rolling on the floor while walking. Relying solely on this tactile feedback, patients reported the position of the avatar leg during virtual walking. Crossmodal interference between vision of the virtual legs and tactile feedback revealed that patients assimilated the virtual lower limbs as if they were their own legs. We propose that the addition of tactile feedback to neuroprosthetic devices is essential to restore a full lower limb perceptual experience in spinal cord injury (SCI) patients, and will ultimately, lead to a higher rate of prosthetic acceptance/use and a better level of motor proficiency. PMID:27640345

  2. The Cognitive and Neural Correlates of Tactile Memory

    ERIC Educational Resources Information Center

    Gallace, Alberto; Spence, Charles

    2009-01-01

    Tactile memory systems are involved in the storage and retrieval of information about stimuli that impinge on the body surface and objects that people explore haptically. Here, the authors review the behavioral, neuropsychological, neurophysiological, and neuroimaging research on tactile memory. This body of research reveals that tactile memory…

  3. Audio-Visual, Visuo-Tactile and Audio-Tactile Correspondences in Preschoolers.

    PubMed

    Nava, Elena; Grassi, Massimo; Turati, Chiara

    2016-01-01

    Interest in crossmodal correspondences has recently seen a renaissance thanks to numerous studies in human adults. Yet, still very little is known about crossmodal correspondences in children, particularly in sensory pairings other than audition and vision. In the current study, we investigated whether 4-5-year-old children match auditory pitch to the spatial motion of visual objects (audio-visual condition). In addition, we investigated whether this correspondence extends to touch, i.e., whether children also match auditory pitch to the spatial motion of touch (audio-tactile condition) and the spatial motion of visual objects to touch (visuo-tactile condition). In two experiments, two different groups of children were asked to indicate which of two stimuli fitted best with a centrally located third stimulus (Experiment 1), or to report whether two presented stimuli fitted together well (Experiment 2). We found sensitivity to the congruency of all of the sensory pairings only in Experiment 2, suggesting that only under specific circumstances can these correspondences be observed. Our results suggest that pitch-height correspondences for audio-visual and audio-tactile combinations may still be weak in preschool children, and speculate that this could be due to immature linguistic and auditory cues that are still developing at age five.

  4. The Houdini Transformation: True, but Illusory.

    PubMed

    Bentler, Peter M; Molenaar, Peter C M

    2012-01-01

    Molenaar (2003, 2011) showed that a common factor model could be transformed into an equivalent model without factors, involving only observed variables and residual errors. He called this invertible transformation the Houdini transformation. His derivation involved concepts from time series and state space theory. This paper verifies the Houdini transformation on a general latent variable model using algebraic methods. The results show that the Houdini transformation is illusory, in the sense that the Houdini transformed model remains a latent variable model. Contrary to common knowledge, a model that is a path model with only observed variables and residual errors may, in fact, be a latent variable model.

  5. The Houdini Transformation: True, but Illusory

    PubMed Central

    Bentler, Peter M.; Molenaar, Peter C. M.

    2012-01-01

    Molenaar (2003, 2011) showed that a common factor model could be transformed into an equivalent model without factors, involving only observed variables and residual errors. He called this invertible transformation the Houdini transformation. His derivation involved concepts from time series and state space theory. This paper verifies the Houdini transformation on a general latent variable model using algebraic methods. The results show that the Houdini transformation is illusory, in the sense that the Houdini transformed model remains a latent variable model. Contrary to common knowledge, a model that is a path model with only observed variables and residual errors may, in fact, be a latent variable model. PMID:23180888

  6. Virtual environment tactile system

    DOEpatents

    Renzi, R.

    1996-12-10

    A method for providing a realistic sense of touch in virtual reality by means of programmable actuator assemblies is disclosed. Each tactile actuator assembly consists of a number of individual actuators whose movement is controlled by a computer and associated drive electronics. When an actuator is energized, the rare earth magnet and the associated contactor, incorporated within the actuator, are set in motion by the opposing electromagnetic field of a surrounding coil. The magnet pushes the contactor forward to contact the skin resulting in the sensation of touch. When the electromagnetic field is turned off, the rare earth magnet and the contactor return to their neutral positions due to the magnetic equilibrium caused by the interaction with the ferrous outer sleeve. The small size and flexible nature of the actuator assemblies permit incorporation into a glove, boot or body suit. The actuator has additional applications, such as, for example, as an accelerometer, an actuator for precisely controlled actuations or to simulate the sensation of braille letters. 28 figs.

  7. Illusory conjunctions in simultanagnosia: coarse coding of visual feature location?

    PubMed

    McCrea, Simon M; Buxbaum, Laurel J; Coslett, H Branch

    2006-01-01

    Simultanagnosia is a disorder characterized by an inability to see more than one object at a time. We report a simultanagnosic patient (ED) with bilateral posterior infarctions who produced frequent illusory conjunctions on tasks involving form and surface features (e.g., a red T) and form alone. ED also produced "blend" errors in which features of one familiar perceptual unit appeared to migrate to another familiar perceptual unit (e.g., "RO" read as "PQ"). ED often misread scrambled letter strings as a familiar word (e.g., "hmoe" read as "home"). Finally, ED's success in reporting two letters in an array was inversely related to the distance between the letters. These findings are consistent with the hypothesis that ED's illusory reflect coarse coding of visual feature location that is ameliorated in part by top-down information from object and word recognition systems; the findings are also consistent, however, with Treisman's Feature Integration Theory. Finally, the data provide additional support for the claim that the dorsal parieto-occipital cortex is implicated in the binding of visual feature information.

  8. Compliant Tactile Sensors

    NASA Technical Reports Server (NTRS)

    Torres-Jara, Eduardo R.

    2011-01-01

    Tactile sensors are currently being designed to sense interactions with human hands or pen-like interfaces. They are generally embedded in screens, keyboards, mousepads, and pushbuttons. However, they are not well fitted to sense interactions with all kinds of objects. A novel sensor was originally designed to investigate robotics manipulation where not only the contact with an object needs to be detected, but also where the object needs to be held and manipulated. This tactile sensor has been designed with features that allow it to sense a large variety of objects in human environments. The sensor is capable of detecting forces coming from any direction. As a result, this sensor delivers a force vector with three components. In contrast to most of the tactile sensors that are flat, this one sticks out from the surface so that it is likely to come in contact with objects. The sensor conforms to the object with which it interacts. This augments the contact's surface, consequently reducing the stress applied to the object. This feature makes the sensor ideal for grabbing objects and other applications that require compliance with objects. The operational range of the sensor allows it to operate well with objects found in peoples' daily life. The fabrication of this sensor is simple and inexpensive because of its compact mechanical configuration and reduced electronics. These features are convenient for mass production of individual sensors as well as dense arrays. The biologically inspired tactile sensor is sensitive to both normal and lateral forces, providing better feedback to the host robot about the object to be grabbed. It has a high sensitivity, enabling its use in manipulation fingers, which typically have low mechanical impedance in order to be very compliant. The construction of the sensor is simple, using inexpensive technologies like silicon rubber molding and standard stock electronics.

  9. Development of multichannel soft tactile sensors having fingerprint structure.

    PubMed

    Tsutsui, H; Murashima, Y; Honma, N; Kobayashi, K

    2014-01-01

    It is possible to accurately recognize the shape of an object or to grip it by setting soft tactile sensors on a robot's hands. We studied a multichannel soft tactile sensor as an artificial hand and evaluated the pressure's response performance from several directions and the slipping and sliding responses. The tactile sensor consisted of multiple pneumatic sensors and a soft cap with a fingerprint structure that was made of silicone gum and was separated from multiple spaces. Evaluation tests showed that the multiple soft tactile sensors estimate both an object's contact force and its contact location. Our tactile sensor also measured the object's roughness by the slide on surface texture.

  10. “Seeing” and “feeling” architecture: how bodily self-consciousness alters architectonic experience and affects the perception of interiors

    PubMed Central

    Pasqualini, Isabella; Llobera, Joan; Blanke, Olaf

    2013-01-01

    Over the centuries architectural theory evolved several notions of embodiment, proposing in the nineteenth and twentieth century that architectonic experience is related to physiological responses of the observer. Recent advances in the cognitive neuroscience of embodiment (or bodily self-consciousness) enable empirical studies of architectonic embodiment. Here, we investigated how architecture modulates bodily self-consciousness by adapting a video-based virtual reality (VR) setup previously used to investigate visuo-tactile mechanisms of bodily self-consciousness. While standing in two different interiors, participants were filmed from behind and watched their own virtual body online on a head-mounted display (HMD). Visuo-tactile strokes were applied in synchronous or asynchronous mode to the participants and their virtual body. Two interiors were simulated in the laboratory by placing the sidewalls either far or near from the participants, generating a large and narrow room. We tested if bodily self-consciousness was differently modulated when participants were exposed to both rooms and whether these changes depend on visuo-tactile stimulation. We measured illusory touch, self-identification, and performed length estimations. Our data show that synchronous stroking of the physical and the virtual body induces illusory touch and self-identification with the virtual body, independent of room-size. Moreover, in the narrow room we observed weak feelings of illusory touch with the sidewalls and of approaching walls. These subjective changes were complemented by a stroking-dependent modulation of length estimation only in the narrow room with participants judging the room-size more accurately during conditions of illusory self-identification. We discuss our findings and previous notions of architectonic embodiment in the context of the cognitive neuroscience of bodily self-consciousness and propose an empirical framework grounded in architecture, cognitive

  11. "Seeing" and "feeling" architecture: how bodily self-consciousness alters architectonic experience and affects the perception of interiors.

    PubMed

    Pasqualini, Isabella; Llobera, Joan; Blanke, Olaf

    2013-01-01

    Over the centuries architectural theory evolved several notions of embodiment, proposing in the nineteenth and twentieth century that architectonic experience is related to physiological responses of the observer. Recent advances in the cognitive neuroscience of embodiment (or bodily self-consciousness) enable empirical studies of architectonic embodiment. Here, we investigated how architecture modulates bodily self-consciousness by adapting a video-based virtual reality (VR) setup previously used to investigate visuo-tactile mechanisms of bodily self-consciousness. While standing in two different interiors, participants were filmed from behind and watched their own virtual body online on a head-mounted display (HMD). Visuo-tactile strokes were applied in synchronous or asynchronous mode to the participants and their virtual body. Two interiors were simulated in the laboratory by placing the sidewalls either far or near from the participants, generating a large and narrow room. We tested if bodily self-consciousness was differently modulated when participants were exposed to both rooms and whether these changes depend on visuo-tactile stimulation. We measured illusory touch, self-identification, and performed length estimations. Our data show that synchronous stroking of the physical and the virtual body induces illusory touch and self-identification with the virtual body, independent of room-size. Moreover, in the narrow room we observed weak feelings of illusory touch with the sidewalls and of approaching walls. These subjective changes were complemented by a stroking-dependent modulation of length estimation only in the narrow room with participants judging the room-size more accurately during conditions of illusory self-identification. We discuss our findings and previous notions of architectonic embodiment in the context of the cognitive neuroscience of bodily self-consciousness and propose an empirical framework grounded in architecture, cognitive

  12. The Design of Tactile Thematic Symbols

    ERIC Educational Resources Information Center

    Lawrence, Megan M.; Lobben, Amy K.

    2011-01-01

    The study reported here investigated the design and legibility of tactile thematic maps, focusing on symbolization and the comprehension of spatial patterns on the maps. The results indicate that discriminable and effective tactile thematic maps can be produced using classed data with a microcapsule paper production method. The participants…

  13. Misunderstanding and Repair in Tactile Auslan

    ERIC Educational Resources Information Center

    Willoughby, Louisa; Manns, Howard; Iwasaki, Shimako; Bartlett, Meredith

    2014-01-01

    This article discusses ways in which misunderstandings arise in Tactile Australian Sign Language (Tactile Auslan) and how they are resolved. Of particular interest are the similarities to and differences from the same processes in visually signed and spoken conversation. This article draws on detailed conversation analysis (CA) and demonstrates…

  14. Real-time vision, tactile cues, and visual form agnosia: removing haptic feedback from a "natural" grasping task induces pantomime-like grasps.

    PubMed

    Whitwell, Robert L; Ganel, Tzvi; Byrne, Caitlin M; Goodale, Melvyn A

    2015-01-01

    Investigators study the kinematics of grasping movements (prehension) under a variety of conditions to probe visuomotor function in normal and brain-damaged individuals. "Natural" prehensile acts are directed at the goal object and are executed using real-time vision. Typically, they also entail the use of tactile, proprioceptive, and kinesthetic sources of haptic feedback about the object ("haptics-based object information") once contact with the object has been made. Natural and simulated (pantomimed) forms of prehension are thought to recruit different cortical structures: patient DF, who has visual form agnosia following bilateral damage to her temporal-occipital cortex, loses her ability to scale her grasp aperture to the size of targets ("grip scaling") when her prehensile movements are based on a memory of a target previewed 2 s before the cue to respond or when her grasps are directed towards a visible virtual target but she is denied haptics-based information about the target. In the first of two experiments, we show that when DF performs real-time pantomimed grasps towards a 7.5 cm displaced imagined copy of a visible object such that her fingers make contact with the surface of the table, her grip scaling is in fact quite normal. This finding suggests that real-time vision and terminal tactile feedback are sufficient to preserve DF's grip scaling slopes. In the second experiment, we examined an "unnatural" grasping task variant in which a tangible target (along with any proxy such as the surface of the table) is denied (i.e., no terminal tactile feedback). To do this, we used a mirror-apparatus to present virtual targets with and without a spatially coincident copy for the participants to grasp. We compared the grasp kinematics from trials with and without terminal tactile feedback to a real-time-pantomimed grasping task (one without tactile feedback) in which participants visualized a copy of the visible target as instructed in our laboratory in the

  15. Crossmodal Congruency Benefits of Tactile and Visual Signalling

    DTIC Science & Technology

    2013-11-12

    modal information format seemed to produce faster and more accurate performance. The question of learning complex tactile communication signals...SECURITY CLASSIFICATION OF: We conducted an experiment in which tactile messages were created based on five common military arm and hand signals. We...compared response times and accuracy rates of novice individuals responding to visual and tactile representations of these messages, which were

  16. Illusory movements induced by tendon vibration in right- and left-handed people.

    PubMed

    Tidoni, Emmanuele; Fusco, Gabriele; Leonardis, Daniele; Frisoli, Antonio; Bergamasco, Massimo; Aglioti, Salvatore Maria

    2015-02-01

    Frequency-specific vibratory stimulation of peripheral tendons induces an illusion of limb movement that may be useful for restoring proprioceptive information in people with sensorimotor disability. This potential application may be limited by inter- and intra-subject variability in the susceptibility to such an illusion, which may depend on a variety of factors. To explore the influence of stimulation parameters and participants' handedness on the movement illusion, we vibrated the right and left tendon of the biceps brachii in a group of right- and left-handed people with five stimulation frequencies (from 40 to 120 Hz in step of 20 Hz). We found that all participants reported the expected illusion of elbow extension, especially after 40 and 60 Hz. Left-handers exhibited less variability in reporting the illusion compared to right-handers across the different stimulation frequencies. Moreover, the stimulation of the non-dominant arm elicited a more vivid illusion with faster onset relative to the stimulation of the dominant arm, an effect that was independent from participants' handedness. Overall, our data show that stimulation frequency, handedness and arm dominance influence the tendon vibration movement illusion. The results are discussed in reference to their relevance in linking motor awareness, improving current devices for motor ability recovery after brain or spinal damage and developing prosthetics and virtual embodiment systems.

  17. Observing the Use of Tactile Schedules

    ERIC Educational Resources Information Center

    Aasen, Gro; Naerland, Terje

    2014-01-01

    This article explores the use of tactile schedules in a heterogeneous sample of children with congenital blindness and varying degrees of additional disabilities. Basic conditions for the use of tactile schedules are proposed and discussed. Child behaviour indicative of some particular functions that can be attained with the use of tactile…

  18. Enhanced tactile encoding and memory recognition in congenital blindness.

    PubMed

    D'Angiulli, Amedeo; Waraich, Paul

    2002-06-01

    Several behavioural studies have shown that early-blind persons possess superior tactile skills. Since neurophysiological data show that early-blind persons recruit visual as well as somatosensory cortex to carry out tactile processing (cross-modal plasticity), blind persons' sharper tactile skills may be related to cortical re-organisation resulting from loss of vision early in their life. To examine the nature of blind individuals' tactile superiority and its implications for cross-modal plasticity, we compared the tactile performance of congenitally totally blind, low-vision and sighted children on raised-line picture identification test and re-test, assessing effects of task familiarity, exploratory strategy and memory recognition. What distinguished the blind from the other children was higher memory recognition and higher tactile encoding associated with efficient exploration. These results suggest that enhanced perceptual encoding and recognition memory may be two cognitive correlates of cross-modal plasticity in congenital blindness.

  19. Exploring Tactile Perceptual Dimensions Using Materials Associated with Sensory Vocabulary.

    PubMed

    Sakamoto, Maki; Watanabe, Junji

    2017-01-01

    Considering tactile sensation when designing products is important because the decision to purchase often depends on how products feel. Numerous psychophysical studies have attempted to identify important factors that describe tactile perceptions. However, the numbers and types of major tactile dimensions reported in previous studies have varied because of differences in materials used across experiments. To obtain a more complete picture of perceptual space with regard to touch, our study focuses on using vocabulary that expresses tactile sensations as a guiding principle for collecting material samples because these types of words are expected to cover all the basic categories within tactile perceptual space. We collected 120 materials based on a variety of Japanese sound-symbolic words for tactile sensations, and used the materials to examine tactile perceptual dimensions and their associations with affective evaluations. Analysis revealed six major dimensions: "Affective evaluation and Friction," "Compliance," "Surface," "Volume," "Temperature," and "Naturalness." These dimensions include four factors that previous studies have regarded as fundamental, as well as two new factors: "Volume" and "Naturalness." Additionally, we showed that "Affective evaluation" is more closely related to the "Friction" component (slipperiness and dryness) than to other tactile perceptual features. Our study demonstrates that using vocabulary could be an effective method for selecting material samples to explore tactile perceptual space.

  20. Tactile friction of topical formulations.

    PubMed

    Skedung, L; Buraczewska-Norin, I; Dawood, N; Rutland, M W; Ringstad, L

    2016-02-01

    The tactile perception is essential for all types of topical formulations (cosmetic, pharmaceutical, medical device) and the possibility to predict the sensorial response by using instrumental methods instead of sensory testing would save time and cost at an early stage product development. Here, we report on an instrumental evaluation method using tactile friction measurements to estimate perceptual attributes of topical formulations. Friction was measured between an index finger and an artificial skin substrate after application of formulations using a force sensor. Both model formulations of liquid crystalline phase structures with significantly different tactile properties, as well as commercial pharmaceutical moisturizing creams being more tactile-similar, were investigated. Friction coefficients were calculated as the ratio of the friction force to the applied load. The structures of the model formulations and phase transitions as a result of water evaporation were identified using optical microscopy. The friction device could distinguish friction coefficients between the phase structures, as well as the commercial creams after spreading and absorption into the substrate. In addition, phase transitions resulting in alterations in the feel of the formulations could be detected. A correlation was established between skin hydration and friction coefficient, where hydrated skin gave rise to higher friction. Also a link between skin smoothening and finger friction was established for the commercial moisturizing creams, although further investigations are needed to analyse this and correlations with other sensorial attributes in more detail. The present investigation shows that tactile friction measurements have potential as an alternative or complement in the evaluation of perception of topical formulations. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. A measurement theory of illusory conjunctions.

    PubMed

    Prinzmetal, William; Ivry, Richard B; Beck, Diane; Shimizu, Naomi

    2002-04-01

    Illusory conjunctions refer to the incorrect perceptual combination of correctly perceived features, such as color and shape. Research on the phenomenon has been hampered by the lack of a measurement theory that accounts for guessing features, as well as the incorrect combination of correctly perceived features. Recently, several investigators have suggested using multinomial models as a tool for measuring feature integration. The authors examined the adequacy of these models in 2 experiments by testing whether model parameters reflect changes in stimulus factors. In a third experiment, confidence ratings were used as a tool for testing the model. Multinomial models accurately reflected both variations in stimulus factors and observers' trial-by-trial confidence ratings.

  2. Path integration in tactile perception of shapes.

    PubMed

    Moscatelli, Alessandro; Naceri, Abdeldjallil; Ernst, Marc O

    2014-11-01

    Whenever we move the hand across a surface, tactile signals provide information about the relative velocity between the skin and the surface. If the system were able to integrate the tactile velocity information over time, cutaneous touch may provide an estimate of the relative displacement between the hand and the surface. Here, we asked whether humans are able to form a reliable representation of the motion path from tactile cues only, integrating motion information over time. In order to address this issue, we conducted three experiments using tactile motion and asked participants (1) to estimate the length of a simulated triangle, (2) to reproduce the shape of a simulated triangular path, and (3) to estimate the angle between two-line segments. Participants were able to accurately indicate the length of the path, whereas the perceived direction was affected by a direction bias (inward bias). The response pattern was thus qualitatively similar to the ones reported in classical path integration studies involving locomotion. However, we explain the directional biases as the result of a tactile motion aftereffect. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Virtual surface characteristics of a tactile display using magneto-rheological fluids.

    PubMed

    Lee, Chul-Hee; Jang, Min-Gyu

    2011-01-01

    Virtual surface characteristics of tactile displays are investigated to characterize the feeling of human touch for a haptic interface application. In order to represent the tactile feeling, a prototype tactile display incorporating Magneto-Rheological (MR) fluid has been developed. Tactile display devices simulate the finger's skin to feel the sensations of contact such as compliance, friction, and topography of the surface. Thus, the tactile display can provide information on the surface of an organic tissue to the surgeon in virtual reality. In order to investigate the compliance feeling of a human finger's touch, normal force responses of a tactile display under various magnetic fields have been assessed. Also, shearing friction force responses of the tactile display are investigated to simulate the action of finger dragging on the surface. Moreover, different matrix arrays of magnetic poles are applied to form the virtual surface topography. From the results, different tactile feelings are observed according to the applied magnetic field strength as well as the arrays of magnetic poles combinations. This research presents a smart tactile display technology for virtual surfaces.

  4. Planar and finger-shaped optical tactile sensors for robotic applications

    NASA Technical Reports Server (NTRS)

    Begej, Stefan

    1988-01-01

    Progress is described regarding the development of optical tactile sensors specifically designed for application to dexterous robotics. These sensors operate on optical principles involving the frustration of total internal reflection at a waveguide/elastomer interface and produce a grey-scale tactile image that represents the normal (vertical) forces of contact. The first tactile sensor discussed is a compact, 32 x 32 planar sensor array intended for mounting on a parallel-jaw gripper. Optical fibers were employed to convey the tactile image to a CCD camera and microprocessor-based image analysis system. The second sensor had the shape and size of a human fingertip and was designed for a dexterous robotic hand. It contained 256 sensing sites (taxels) distributed in a dual-density pattern that included a tactile fovea near the tip measuring 13 x 13 mm and containing 169 taxels. The design and construction details of these tactile sensors are presented, in addition to photographs of tactile imprints.

  5. Vibrotactile pattern recognition: a portable compact tactile matrix.

    PubMed

    Thullier, Francine; Bolmont, Benoît; Lestienne, Francis G

    2012-02-01

    Compact tactile matrix (CTM) is a vibrotactile device composed of a seven-by-seven array of electromechanical vibrators "tactip" used to represent tactile patterns applied to a small skin area. The CTM uses a dynamic feature to generate spatiotemporal tactile patterns. The design requirements focus particularly on maximizing the transmission of the vibration from one tactip to the others as well as to the skin over a square area of 16 cm (2) while simultaneously minimizing the transmission of vibrations throughout the overall structure of the CTM. Experiments were conducted on 22 unpracticed subjects to evaluate how the CTM could be used to develop a tactile semantics for communication of instructions in order to test the ability of the subjects to identify: 1) directional prescriptors for gesture guidance and 2) instructional commands for operational task requirements in a military context. The results indicate that, after familiarization, recognition accuracies in the tactile patterns were remarkably precise for more 80% of the subjects. © 2011 IEEE

  6. Real-time edge tracking using a tactile sensor

    NASA Technical Reports Server (NTRS)

    Berger, Alan D.; Volpe, Richard; Khosla, Pradeep K.

    1989-01-01

    Object recognition through the use of input from multiple sensors is an important aspect of an autonomous manipulation system. In tactile object recognition, it is necessary to determine the location and orientation of object edges and surfaces. A controller is proposed that utilizes a tactile sensor in the feedback loop of a manipulator to track along edges. In the control system, the data from the tactile sensor is first processed to find edges. The parameters of these edges are then used to generate a control signal to a hybrid controller. Theory is presented for tactile edge detection and an edge tracking controller. In addition, experimental verification of the edge tracking controller is presented.

  7. First-Time Mothers' Use of Music and Movement with Their Young Infants: The Impact of a Teaching Program.

    ERIC Educational Resources Information Center

    Vlismas, Wendy; Bowes, Jennifer

    1999-01-01

    Examined impact of a 5-week music/movement program involving relaxation, kinesics, singing, visual contact, and tactile stimulation on first-time mothers' use of music and movement with their infants. Found that the program extended mothers' use of relaxation to music and rhythmical movement with their infants but not the use of song and massage…

  8. Illusory conjunctions in visual short-term memory: Individual differences in corpus callosum connectivity and splitting attention between the two hemifields.

    PubMed

    Qin, Shuo; Ray, Nicholas R; Ramakrishnan, Nithya; Nashiro, Kaoru; O'Connell, Margaret A; Basak, Chandramallika

    2016-11-01

    Overloading the capacity of visual attention can result in mistakenly combining the various features of an object, that is, illusory conjunctions. We hypothesize that if the two hemispheres separately process visual information by splitting attention, connectivity of corpus callosum-a brain structure integrating the two hemispheres-would predict the degree of illusory conjunctions. In the current study, we assessed two types of illusory conjunctions using a memory-scanning paradigm; the features were either presented across the two opposite hemifields or within the same hemifield. Four objects, each with two visual features, were briefly presented together followed by a probe-recognition and a confidence rating for the recognition accuracy. MRI scans were also obtained. Results indicated that successful recollection during probe recognition was better for across hemifields conjunctions compared to within hemifield conjunctions, lending support to the bilateral advantage of the two hemispheres in visual short-term memory. Age-related differences regarding the underlying mechanisms of the bilateral advantage indicated greater reliance on recollection-based processing in young and on familiarity-based processing in old. Moreover, the integrity of the posterior corpus callosum was more predictive of opposite hemifield illusory conjunctions compared to within hemifield illusory conjunctions, even after controlling for age. That is, individuals with lesser posterior corpus callosum connectivity had better recognition for objects when their features were recombined from the opposite hemifields than from the same hemifield. This study is the first to investigate the role of the corpus callosum in splitting attention between versus within hemifields. © 2016 Society for Psychophysiological Research.

  9. Piezoelectric Polymer Tactile Sensor Arrays for Robotics.

    DTIC Science & Technology

    1987-12-01

    response to slow and fast stimuli (Dario and others, 1984:2). The touch receptors relate tactile information through a variety of tactile sensory...flexure. The only occurrence when an evaporated electrode broke (and became intermit - tently open circuited) was during the measurement of the PPTSA *4

  10. 3D Printed Stretchable Tactile Sensors.

    PubMed

    Guo, Shuang-Zhuang; Qiu, Kaiyan; Meng, Fanben; Park, Sung Hyun; McAlpine, Michael C

    2017-07-01

    The development of methods for the 3D printing of multifunctional devices could impact areas ranging from wearable electronics and energy harvesting devices to smart prosthetics and human-machine interfaces. Recently, the development of stretchable electronic devices has accelerated, concomitant with advances in functional materials and fabrication processes. In particular, novel strategies have been developed to enable the intimate biointegration of wearable electronic devices with human skin in ways that bypass the mechanical and thermal restrictions of traditional microfabrication technologies. Here, a multimaterial, multiscale, and multifunctional 3D printing approach is employed to fabricate 3D tactile sensors under ambient conditions conformally onto freeform surfaces. The customized sensor is demonstrated with the capabilities of detecting and differentiating human movements, including pulse monitoring and finger motions. The custom 3D printing of functional materials and devices opens new routes for the biointegration of various sensors in wearable electronics systems, and toward advanced bionic skin applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Illusory motion reversal is caused by rivalry, not by perceptual snapshots of the visual field.

    PubMed

    Kline, Keith; Holcombe, Alex O; Eagleman, David M

    2004-10-01

    In stroboscopic conditions--such as motion pictures--rotating objects may appear to rotate in the reverse direction due to under-sampling (aliasing). A seemingly similar phenomenon occurs in constant sunlight, which has been taken as evidence that the visual system processes discrete "snapshots" of the outside world. But if snapshots are indeed taken of the visual field, then when a rotating drum appears to transiently reverse direction, its mirror image should always appeared to reverse direction simultaneously. Contrary to this hypothesis, we found that when observers watched a rotating drum and its mirror image, almost all illusory motion reversals occurred for only one image at a time. This result indicates that the motion reversal illusion cannot be explained by snapshots of the visual field. The same result is found when the two images are presented within one visual hemifield, further ruling out the possibility that discrete sampling of the visual field occurs separately in each hemisphere. The frequency distribution of illusory reversal durations approximates a gamma distribution, suggesting perceptual rivalry as a better explanation for illusory motion reversal. After adaptation of motion detectors coding for the correct direction, the activity of motion-sensitive neurons coding for motion in the reverse direction may intermittently become dominant and drive the perception of motion.

  12. Endoscopic vs. tactile evaluation of subgingival calculus.

    PubMed

    Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M

    2014-08-01

    Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (p<0.005). Mean changes (reduction) in calculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (p<0.0001). However, further reductions in calculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (p<0.025), indicating that this methodology was able to more precisely detect calculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.

  13. Hearing visuo-tactile synchrony - Sound-induced proprioceptive drift in the invisible hand illusion.

    PubMed

    Darnai, Gergely; Szolcsányi, Tibor; Hegedüs, Gábor; Kincses, Péter; Kállai, János; Kovács, Márton; Simon, Eszter; Nagy, Zsófia; Janszky, József

    2017-02-01

    The rubber hand illusion (RHI) and its variant the invisible hand illusion (IHI) are useful for investigating multisensory aspects of bodily self-consciousness. Here, we explored whether auditory conditioning during an RHI could enhance the trisensory visuo-tactile-proprioceptive interaction underlying the IHI. Our paradigm comprised of an IHI session that was followed by an RHI session and another IHI session. The IHI sessions had two parts presented in counterbalanced order. One part was conducted in silence, whereas the other part was conducted on the backdrop of metronome beats that occurred in synchrony with the brush movements used for the induction of the illusion. In a first experiment, the RHI session also involved metronome beats and was aimed at creating an associative memory between the brush stroking of a rubber hand and the sounds. An analysis of IHI sessions showed that the participants' perceived hand position drifted more towards the body-midline in the metronome relative to the silent condition without any sound-related session differences. Thus, the sounds, but not the auditory RHI conditioning, influenced the IHI. In a second experiment, the RHI session was conducted without metronome beats. This confirmed the conditioning-independent presence of sound-induced proprioceptive drift in the IHI. Together, these findings show that the influence of visuo-tactile integration on proprioceptive updating is modifiable by irrelevant auditory cues merely through the temporal correspondence between the visuo-tactile and auditory events. © 2016 The British Psychological Society.

  14. Merkel cells transduce and encode tactile stimuli to drive Aβ-afferent impulses

    PubMed Central

    Ikeda, Ryo; Cha, Myeounghoon; Ling, Jennifer; Jia, Zhanfeng; Coyle, Dennis; Gu, Jianguo G.

    2014-01-01

    SUMMARY Sensory systems for detecting tactile stimuli have evolved from touch-sensing nerves in invertebrates to complicated tactile end-organs in mammals. Merkel discs are tactile end-organs consisting of Merkel cells and Aβ-afferent nerve endings, and are localized in fingertips, whisker hair follicles and other touch-sensitive spots. Merkel discs transduce touch into slowly adapting impulses to enable tactile discrimination, but their transduction and encoding mechanisms remain unknown. Using rat whisker hair follicles, we show that Merkel cells rather than Aβ-afferent nerve endings are primary sites of tactile transduction, and identify the Piezo2 ion channel as the Merkel cell mechanical transducer. Piezo2 transduces tactile stimuli into Ca2+-action potentials in Merkel cells, which drive Aβ-afferent nerve endings to fire slowly adapting impulses. We further demonstrate that Piezo2 and Ca2+-action potentials in Merkel cells are required for behavioral tactile responses. Our findings provide insights into how tactile end-organs function and have clinical implications for tactile dysfunctions. PMID:24746027

  15. Tactile priming modulates the activation of the fronto-parietal circuit during tactile angle match and non-match processing: an fMRI study

    PubMed Central

    Yang, Jiajia; Yu, Yinghua; Kunita, Akinori; Huang, Qiang; Wu, Jinglong; Sawamoto, Nobukatsu; Fukuyama, Hidenao

    2014-01-01

    The repetition of a stimulus task reduces the neural activity within certain cortical regions responsible for working memory (WM) processing. Although previous evidence has shown that repeated vibrotactile stimuli reduce the activation in the ventrolateral prefrontal cortex, whether the repeated tactile spatial stimuli triggered the priming effect correlated with the same cortical region remains unclear. Therefore, we used event-related functional magnetic resonance imaging (fMRI) and a delayed match-to-sample task to investigate the contributions of the priming effect to tactile spatial WM processing. Fourteen healthy volunteers were asked to encode three tactile angle stimuli during the encoding phase and one tactile angle stimulus during the recognition phase. Then, they answered whether the last angle stimulus was presented during the encoding phase. As expected, both the Match and Non-Match tasks activated a similar cerebral network. The critical new finding was decreased brain activity in the left inferior frontal gyrus (IFG), the right posterior parietal cortex (PPC) and bilateral medial frontal gyri (mFG) for the match task compared to the Non-Match task. Therefore, we suggest that the tactile priming engaged repetition suppression mechanisms during tactile angle matching, and this process decreased the activation of the fronto-parietal circuit, including IFG, mFG and PPC. PMID:25566010

  16. Connecting the dots: Illusory pattern perception predicts belief in conspiracies and the supernatural

    PubMed Central

    Douglas, Karen M.; De Inocencio, Clara

    2017-01-01

    Abstract A common assumption is that belief in conspiracy theories and supernatural phenomena are grounded in illusory pattern perception. In the present research we systematically tested this assumption. Study 1 revealed that such irrational beliefs are related to perceiving patterns in randomly generated coin toss outcomes. In Study 2, pattern search instructions exerted an indirect effect on irrational beliefs through pattern perception. Study 3 revealed that perceiving patterns in chaotic but not in structured paintings predicted irrational beliefs. In Study 4, we found that agreement with texts supporting paranormal phenomena or conspiracy theories predicted pattern perception. In Study 5, we manipulated belief in a specific conspiracy theory. This manipulation influenced the extent to which people perceive patterns in world events, which in turn predicted unrelated irrational beliefs. We conclude that illusory pattern perception is a central cognitive mechanism accounting for conspiracy theories and supernatural beliefs. PMID:29695889

  17. Connecting the dots: Illusory pattern perception predicts belief in conspiracies and the supernatural.

    PubMed

    van Prooijen, Jan-Willem; Douglas, Karen M; De Inocencio, Clara

    2018-04-01

    A common assumption is that belief in conspiracy theories and supernatural phenomena are grounded in illusory pattern perception. In the present research we systematically tested this assumption. Study 1 revealed that such irrational beliefs are related to perceiving patterns in randomly generated coin toss outcomes. In Study 2, pattern search instructions exerted an indirect effect on irrational beliefs through pattern perception. Study 3 revealed that perceiving patterns in chaotic but not in structured paintings predicted irrational beliefs. In Study 4, we found that agreement with texts supporting paranormal phenomena or conspiracy theories predicted pattern perception. In Study 5, we manipulated belief in a specific conspiracy theory. This manipulation influenced the extent to which people perceive patterns in world events, which in turn predicted unrelated irrational beliefs. We conclude that illusory pattern perception is a central cognitive mechanism accounting for conspiracy theories and supernatural beliefs.

  18. Tactile mental body parts representation in obesity.

    PubMed

    Scarpina, Federica; Castelnuovo, Gianluca; Molinari, Enrico

    2014-12-30

    Obese people׳s distortions in visually-based mental body-parts representations have been reported in previous studies, but other sensory modalities have largely been neglected. In the present study, we investigated possible differences in tactilely-based body-parts representation between an obese and a healthy-weight group; additionally we explore the possible relationship between the tactile- and the visually-based body representation. Participants were asked to estimate the distance between two tactile stimuli that were simultaneously administered on the arm or on the abdomen, in the absence of visual input. The visually-based body-parts representation was investigated by a visual imagery method in which subjects were instructed to compare the horizontal extension of body part pairs. According to the results, the obese participants overestimated the size of the tactilely-perceived distances more than the healthy-weight group when the arm, and not the abdomen, was stimulated. Moreover, they reported a lower level of accuracy than did the healthy-weight group when estimating horizontal distances relative to their bodies, confirming an inappropriate visually-based mental body representation. Our results imply that body representation disturbance in obese people is not limited to the visual mental domain, but it spreads to the tactilely perceived distances. The inaccuracy was not a generalized tendency but was body-part related. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Artificial tactile sensing in minimally invasive surgery - a new technical approach.

    PubMed

    Schostek, Sebastian; Ho, Chi-Nghia; Kalanovic, Daniel; Schurr, Marc O

    2006-01-01

    The loss of tactile sensation is a commonly known drawback of minimally invasive surgery (MIS). Since the advent of MIS, research activities in providing tactile information to the surgeon are still ongoing, in order to improve patient safety and to extend the indications for MIS. We have designed a tactile sensor system comprising a tactile laparoscopic grasper for surgical palpation. For this purpose, we developed a novel tactile sensor technology which allows the manufacturing of an integrated sensor array within an acceptable price range. The array was integrated into the jaws of a 10mm laparoscopic grasper. The tactile data are transferred wirelessly via Bluetooth and are presented visually to the surgeon. The goal was to be able to obtain information about the shape and consistency of tissue structures by gently compressing the tissue between the jaws of the tactile instrument and thus to be able to recognize and assess anatomical or pathological structures, even if they are hidden in the tissue. With a prototype of the tactile sensor system we have conducted bench-tests as well as in-vitro and in-vivo experiments. The system proved feasibility in an experimental environment, it was easy to use, and the novel tactile sensor array was applicable for both palpation and grasping manoeuvres with forces of up to 60N. The tactile data turned out to be a useful supplement to the minimal amount of haptic feedback that is provided by current endoscopic instruments and the endoscopic image under certain conditions.

  20. Real-time vision, tactile cues, and visual form agnosia: removing haptic feedback from a “natural” grasping task induces pantomime-like grasps

    PubMed Central

    Whitwell, Robert L.; Ganel, Tzvi; Byrne, Caitlin M.; Goodale, Melvyn A.

    2015-01-01

    Investigators study the kinematics of grasping movements (prehension) under a variety of conditions to probe visuomotor function in normal and brain-damaged individuals. “Natural” prehensile acts are directed at the goal object and are executed using real-time vision. Typically, they also entail the use of tactile, proprioceptive, and kinesthetic sources of haptic feedback about the object (“haptics-based object information”) once contact with the object has been made. Natural and simulated (pantomimed) forms of prehension are thought to recruit different cortical structures: patient DF, who has visual form agnosia following bilateral damage to her temporal-occipital cortex, loses her ability to scale her grasp aperture to the size of targets (“grip scaling”) when her prehensile movements are based on a memory of a target previewed 2 s before the cue to respond or when her grasps are directed towards a visible virtual target but she is denied haptics-based information about the target. In the first of two experiments, we show that when DF performs real-time pantomimed grasps towards a 7.5 cm displaced imagined copy of a visible object such that her fingers make contact with the surface of the table, her grip scaling is in fact quite normal. This finding suggests that real-time vision and terminal tactile feedback are sufficient to preserve DF’s grip scaling slopes. In the second experiment, we examined an “unnatural” grasping task variant in which a tangible target (along with any proxy such as the surface of the table) is denied (i.e., no terminal tactile feedback). To do this, we used a mirror-apparatus to present virtual targets with and without a spatially coincident copy for the participants to grasp. We compared the grasp kinematics from trials with and without terminal tactile feedback to a real-time-pantomimed grasping task (one without tactile feedback) in which participants visualized a copy of the visible target as instructed in our

  1. Tactile roughness perception in the presence of olfactory and trigeminal stimulants

    PubMed Central

    Koijck, Lara A.; Van Erp, Jan B.F.

    2015-01-01

    Previous research has shown that odorants consistently evoke associations with textures and their tactile properties like smoothness and roughness. Also, it has been observed that olfaction can modulate tactile perception. We therefore hypothesized that tactile roughness perception may be biased towards the somatosensory connotation of an ambient odorant. We performed two experiments to test this hypothesis. In the first experiment, we investigated the influence of ambient chemosensory stimuli with different roughness connotations on tactile roughness perception. In addition to a pleasant odor with a connotation of softness (PEA), we also included a trigeminal stimulant with a rough, sharp or prickly connotation (Ethanol). We expected that—compared to a No-odorant control condition—tactile texture perception would be biased towards smoothness in the presence of PEA and towards roughness in the presence of Ethanol. However, our results show no significant interaction between chemosensory stimulation and perceived tactile surface roughness. It could be argued that ambient odors may be less effective in stimulating crossmodal associations, since they are by definition extraneous to the tactile stimuli. In an attempt to optimize the conditions for sensory integration, we therefore performed a second experiment in which the olfactory and tactile stimuli were presented in synchrony and in close spatial proximity. In addition, we included pleasant (Lemon) and unpleasant (Indole) odorants that are known to have the ability to affect tactile perception. We expected that tactile stimuli would be perceived as less rough when simultaneously presented with Lemon or PEA (both associated with softness) than when presented with Ethanol or Indole (odors that can be associated with roughness). Again, we found no significant main effect of chemosensory condition on perceived tactile roughness. We discuss the limitations of this study and we present suggestions for future research

  2. Microfabricated Tactile Sensors for Biomedical Applications: A Review

    PubMed Central

    Saccomandi, Paola; Schena, Emiliano; Oddo, Calogero Maria; Zollo, Loredana; Silvestri, Sergio; Guglielmelli, Eugenio

    2014-01-01

    During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described. PMID:25587432

  3. A Pneumatic Tactile Sensor for Co-Operative Robots

    PubMed Central

    He, Rui; Yu, Jianjun; Zuo, Guoyu

    2017-01-01

    Tactile sensors of comprehensive functions are urgently needed for the advanced robot to co-exist and co-operate with human beings. Pneumatic tactile sensors based on air bladder possess some noticeable advantages for human-robot interaction application. In this paper, we construct a pneumatic tactile sensor and apply it on the fingertip of robot hand to realize the sensing of force, vibration and slippage via the change of the pressure of the air bladder, and we utilize the sensor to perceive the object’s features such as softness and roughness. The pneumatic tactile sensor has good linearity, repeatability and low hysteresis and both its size and sensing range can be customized by using different material as well as different thicknesses of the air bladder. It is also simple and cheap to fabricate. Therefore, the pneumatic tactile sensor is suitable for the application of co-operative robots and can be widely utilized to improve the performance of service robots. We can apply it to the fingertip of the robot to endow the robotic hand with the ability to co-operate with humans and handle the fragile objects because of the inherent compliance of the air bladder. PMID:29125565

  4. Microfabricated tactile sensors for biomedical applications: a review.

    PubMed

    Saccomandi, Paola; Schena, Emiliano; Oddo, Calogero Maria; Zollo, Loredana; Silvestri, Sergio; Guglielmelli, Eugenio

    2014-12-01

    During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described.

  5. Review of Recent Inkjet-Printed Capacitive Tactile Sensors

    PubMed Central

    Salim, Ahmed

    2017-01-01

    Inkjet printing is an advanced printing technology that has been used to develop conducting layers, interconnects and other features on a variety of substrates. It is an additive manufacturing process that offers cost-effective, lightweight designs and simplifies the fabrication process with little effort. There is hardly sufficient research on tactile sensors and inkjet printing. Advancements in materials science and inkjet printing greatly facilitate the realization of sophisticated tactile sensors. Starting from the concept of capacitive sensing, a brief comparison of printing techniques, the essential requirements of inkjet-printing and the attractive features of state-of-the art inkjet-printed tactile sensors developed on diverse substrates (paper, polymer, glass and textile) are presented in this comprehensive review. Recent trends in inkjet-printed wearable/flexible and foldable tactile sensors are evaluated, paving the way for future research. PMID:29125584

  6. Robust tactile sensory responses in finger area of primate motor cortex relevant to prosthetic control

    NASA Astrophysics Data System (ADS)

    Schroeder, Karen E.; Irwin, Zachary T.; Bullard, Autumn J.; Thompson, David E.; Bentley, J. Nicole; Stacey, William C.; Patil, Parag G.; Chestek, Cynthia A.

    2017-08-01

    Objective. Challenges in improving the performance of dexterous upper-limb brain-machine interfaces (BMIs) have prompted renewed interest in quantifying the amount and type of sensory information naturally encoded in the primary motor cortex (M1). Previous single unit studies in monkeys showed M1 is responsive to tactile stimulation, as well as passive and active movement of the limbs. However, recent work in this area has focused primarily on proprioception. Here we examined instead how tactile somatosensation of the hand and fingers is represented in M1. Approach. We recorded multi- and single units and thresholded neural activity from macaque M1 while gently brushing individual finger pads at 2 Hz. We also recorded broadband neural activity from electrocorticogram (ECoG) grids placed on human motor cortex, while applying the same tactile stimulus. Main results. Units displaying significant differences in firing rates between individual fingers (p  <  0.05) represented up to 76.7% of sorted multiunits across four monkeys. After normalizing by the number of channels with significant motor finger responses, the percentage of electrodes with significant tactile responses was 74.9%  ±  24.7%. No somatotopic organization of finger preference was obvious across cortex, but many units exhibited cosine-like tuning across multiple digits. Sufficient sensory information was present in M1 to correctly decode stimulus position from multiunit activity above chance levels in all monkeys, and also from ECoG gamma power in two human subjects. Significance. These results provide some explanation for difficulties experienced by motor decoders in clinical trials of cortically controlled prosthetic hands, as well as the general problem of disentangling motor and sensory signals in primate motor cortex during dextrous tasks. Additionally, examination of unit tuning during tactile and proprioceptive inputs indicates cells are often tuned differently in different

  7. Unmyelinated tactile cutaneous nerves signal erotic sensations.

    PubMed

    Jönsson, Emma H; Backlund Wasling, Helena; Wagnbeck, Vicktoria; Dimitriadis, Menelaos; Georgiadis, Janniko R; Olausson, Håkan; Croy, Ilona

    2015-06-01

    Intrapersonal touch is a powerful tool for communicating emotions and can among many things evoke feelings of eroticism and sexual arousal. The peripheral neural mechanisms of erotic touch signaling have been less studied. C tactile afferents (unmyelinated low-threshold mechanoreceptors), known to underpin pleasant aspects of touch processing, have been posited to play an important role. In two studies, we investigated the relationship between C tactile activation and the perception of erotic and pleasant touch, using tactile brushing stimulation. In total, 66 healthy subjects (37 women, age range 19-51 years) were examined. In study 1 (n = 20), five different stroking velocities were applied to the forearm and the inner thigh. The participants answered questions about partnership, mood, and touch. In study 2 (n = 46), the same five stroking velocities were applied to the forearm. The participants answered questions about partnership, touch, and sexuality. Both touch eroticism and pleasantness were rated significantly higher for C tactile optimal velocities compared with suboptimal velocities. No difference was found between the ratings of the thigh and the forearm. The velocity-dependent rating curves of pleasantness, intensity, and eroticism differed from each other. Pleasantness was best explained by a quadratic fit, intensity by a linear fit, and eroticism by both. A linear transformation of pleasantness and intensity predicted the observed eroticism ratings reliably. Eroticism ratings were negatively correlated with length of relationship. Touch was rated most erotic when perceived as pleasant and weak. In human hairy skin, perception of pleasantness is correlated with the firing rate of C tactile afferents, and perception of intensity is correlated with the firing rate of Aβ afferents. Accordingly, eroticism may be perceived most readily for touch stimuli that induce high activity in C tactile fibers and low activity in Aβ fibers. © 2015 International

  8. Texture- and deformability-based surface recognition by tactile image analysis.

    PubMed

    Khasnobish, Anwesha; Pal, Monalisa; Tibarewala, D N; Konar, Amit; Pal, Kunal

    2016-08-01

    Deformability and texture are two unique object characteristics which are essential for appropriate surface recognition by tactile exploration. Tactile sensation is required to be incorporated in artificial arms for rehabilitative and other human-computer interface applications to achieve efficient and human-like manoeuvring. To accomplish the same, surface recognition by tactile data analysis is one of the prerequisites. The aim of this work is to develop effective technique for identification of various surfaces based on deformability and texture by analysing tactile images which are obtained during dynamic exploration of the item by artificial arms whose gripper is fitted with tactile sensors. Tactile data have been acquired, while human beings as well as a robot hand fitted with tactile sensors explored the objects. The tactile images are pre-processed, and relevant features are extracted from the tactile images. These features are provided as input to the variants of support vector machine (SVM), linear discriminant analysis and k-nearest neighbour (kNN) for classification. Based on deformability, six household surfaces are recognized from their corresponding tactile images. Moreover, based on texture five surfaces of daily use are classified. The method adopted in the former two cases has also been applied for deformability- and texture-based recognition of four biomembranes, i.e. membranes prepared from biomaterials which can be used for various applications such as drug delivery and implants. Linear SVM performed best for recognizing surface deformability with an accuracy of 83 % in 82.60 ms, whereas kNN classifier recognizes surfaces of daily use having different textures with an accuracy of 89 % in 54.25 ms and SVM with radial basis function kernel recognizes biomembranes with an accuracy of 78 % in 53.35 ms. The classifiers are observed to generalize well on the unseen test datasets with very high performance to achieve efficient material

  9. Cathodal transcranial direct current stimulation can stabilize perception of movement: Evidence from the two-thirds power law illusion.

    PubMed

    Scocchia, Lisa; Bolognini, Nadia; Convento, Silvia; Stucchi, Natale

    2015-11-16

    Human movements conform to specific kinematic laws of motion. One of such laws, the "two-thirds power law", describes the systematic co-variation between curvature and velocity of body movements. Noticeably, the same law also influences the perception of moving stimuli: the velocity of a dot moving along a curvilinear trajectory is perceived as uniform when the dot kinematics complies with the two-thirds power law. Instead, if the dot moves at constant speed, its velocity is perceived as highly non-uniform. This dynamic visual illusion points to a strong coupling between action and perception; however, how this coupling is implemented in the brain remains elusive. In this study, we tested whether the premotor cortex (PM) and the primary visual cortex (V1) play a role in the illusion by means of transcranial Direct Current Stimulation (tDCS). All participants underwent three tDCS sessions during which they received active or sham cathodal tDCS (1.5mA) over PM or V1 of the left hemisphere. During tDCS, participants were required to adjust the velocity of a dot moving along an elliptical trajectory until it looked uniform across the whole trajectory. Results show that occipital tDCS decreases the illusion variability both within and across participants, as compared to sham tDCS. This means that V1 stimulation increases individual sensitivity to the illusory motion and also increases coherence across different observers. Conversely, the illusion seems resistant to tDCS in terms of its magnitude, with cathodal stimulation of V1 or PM not affecting the amount of the illusory effect. Our results provide evidence for strong visuo-motor coupling in visual perception: the velocity of a dot moving along an elliptical trajectory is perceived as uniform only when its kinematics closely complies to the same law of motion that constrains human movement production. Occipital stimulation by cathodal tDCS can stabilize such illusory percept. Copyright © 2015 Elsevier Ireland Ltd

  10. Displaying Sensed Tactile Cues with a Fingertip Haptic Device.

    PubMed

    Pacchierotti, Claudio; Prattichizzo, Domenico; Kuchenbecker, Katherine J

    2015-01-01

    Telerobotic systems enable humans to explore and manipulate remote environments for applications such as surgery and disaster response, but few such systems provide the operator with cutaneous feedback. This article presents a novel approach to remote cutaneous interaction; our method is compatible with any fingertip tactile sensor and any mechanical tactile display device, and it does not require a position/force or skin deformation model. Instead, it directly maps the sensed stimuli to the best possible input commands for the device's motors using a data set recorded with the tactile sensor inside the device. As a proof of concept, we considered a haptic system composed of a BioTac tactile sensor, in charge of measuring contact deformations, and a custom 3-DoF cutaneous device with a flat contact platform, in charge of applying deformations to the user's fingertip. To validate the proposed approach and discover its inherent tradeoffs, we carried out two remote tactile interaction experiments. The first one evaluated the error between the tactile sensations registered by the BioTac in a remote environment and the sensations created by the cutaneous device for six representative tactile interactions and 27 variations of the display algorithm. The normalized average errors in the best condition were 3.0 percent of the BioTac's full 12-bit scale. The second experiment evaluated human subjects' experiences for the same six remote interactions and eight algorithm variations. The average subjective rating for the best algorithm variation was 8.2 out of 10, where 10 is best.

  11. MEMS tactile display: from fabrication to characterization

    NASA Astrophysics Data System (ADS)

    Miki, Norihisa; Kosemura, Yumi; Watanabe, Junpei; Ishikawa, Hiroaki

    2014-03-01

    We report fabrication and characterization of MEMS-based tactile display that can display users various tactile information, such as Braille codes and surface textures. The display consists of 9 micro-actuators that are equipped with hydraulic displacement amplification mechanism (HDAM) to achieve large enough displacement to stimulate the human tactile receptors. HDAM encapsulates incompressible liquids. We developed a liquid encapsulation process, which we termed as Bonding-in-Liquid Technique, where bonding with a UV-curable resin in glycerin is conducted in the liquid, which prevented interfusion of air bubbles and deformation of the membrane during the bonding. HDAM successfully amplified the displacement generated by piezoelectric actuators by a factor of 6. The display could virtually produce "rough" and "smooth" surfaces, by controlling the vibration frequency, displacement, and the actuation periods of an actuator until the adjacent actuator was driven. We introduced a sample comparison method to characterize the surfaces, which involves human tactile sensation. First, we prepared samples whose mechanical properties are known. We displayed a surface texture to the user by controlling the parameters and then, the user selects a sample that has the most similar surface texture. By doing so, we can correlate the parameters with the mechanical properties of the sample as well as find the sets of the parameters that can provide similar tactile information to many users. The preliminary results with respect to roughness and hardness is presented.

  12. A Single Session of Mirror-based Tactile and Motor Training Improves Tactile Dysfunction in Children with Unilateral Cerebral Palsy: A Replicated Randomized Controlled Case Series.

    PubMed

    Auld, Megan L; Johnston, Leanne M; Russo, Remo N; Moseley, G Lorimer

    2017-10-01

    This replicated randomized controlled crossover case series investigated the effect of mirror-based tactile and motor training on tactile registration and perception in children with unilateral cerebral palsy (UCP). Six children with UCP (6-18 years; median 10 years, five male, three-left hemiplegia, four-manual ability classification system (MACS) I, one MACS II and one MACS III) participated. They attended two 90-minute sessions - one of mirror-based training and one of standard practice, bimanual therapy - in alternated order. Tactile registration (Semmes Weinstein Monofilaments) and perception (double simultaneous or single-point localization) were assessed before and after each session. Change was estimated using reliable change index (RCI). Tactile perception improved in four participants (RCI > 1.75), with mirror-based training, but was unchanged with bimanual therapy (RCI < 1.0 for all participants). Neither intervention affected tactile registration. Mirror-based training demonstrates potential to improve tactile perception in children with UCP. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Tactile texture and friction of soft sponge surfaces.

    PubMed

    Takahashi, Akira; Suzuki, Makoto; Imai, Yumi; Nonomura, Yoshimune

    2015-06-01

    We evaluated the tactile texture and frictional properties of five soft sponges with various cell sizes. The frictional forces were measured by a friction meter containing a contact probe with human-finger-like geometry and mechanical properties. When the subjects touched these sponges with their fingers, hard-textured sponges were deemed unpleasant. This tactile feeling changed with friction factors including friction coefficients, their temporal patterns, as well as mechanical and shape factors. These findings provide useful information on how to control the tactile textures of various sponges. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Differential effects of tactile high- and low-frequency stimulation on tactile discrimination in human subjects.

    PubMed

    Ragert, Patrick; Kalisch, Tobias; Bliem, Barbara; Franzkowiak, Stephanie; Dinse, Hubert R

    2008-01-23

    Long-term potentiation (LTP) and long-term depression (LTD) play important roles in mediating activity-dependent changes in synaptic transmission and are believed to be crucial mechanisms underlying learning and cortical plasticity. In human subjects, however, the lack of adequate input stimuli for the induction of LTP and LTD makes it difficult to study directly the impact of such protocols on behavior. Using tactile high- and low-frequency stimulation protocols in humans, we explored the potential of such protocols for the induction of perceptual changes. We delivered tactile high-frequency and low-frequency stimuli (t-HFS, t-LFS) to skin sites of approximately 50 mm2 on the tip of the index finger. As assessed by 2-point discrimination, we demonstrate that 20 minutes of t-HFS improved tactile discrimination, while t-LFS impaired performance. T-HFS-effects were stable for at least 24 hours whereas t-LFS-induced changes recovered faster. While t-HFS changes were spatially very specific with no changes on the neighboring fingers, impaired tactile performance after t-LFS was also observed on the right middle-finger. A central finding was that for both t-LFS and t-HFS perceptual changes were dependent on the size of the stimulated skin area. No changes were observed when the stimulated area was very small (< 1 mm2) indicating special requirements for spatial summation. Our results demonstrate differential effects of such protocols in a frequency specific manner that might be related to LTP- and LTD-like changes in human subjects.

  15. The Alternative Omen Effect: Illusory negative correlation between the outcomes of choice options.

    PubMed

    Marciano-Romm, Déborah; Romm, Assaf; Bourgeois-Gironde, Sacha; Deouell, Leon Y

    2016-01-01

    In situations of choice between uncertain options, one might get feedback on both the outcome of the chosen option and the outcome of the unchosen option ("the alternative"). Extensive research has shown that when both outcomes are eventually revealed, the alternative's outcome influences the way people evaluate their own outcome. In a series of experiments, we examined whether the outcome of the alternative plays an additional role in the decision-making process by creating expectations regarding the outcome of the chosen option. Specifically, we hypothesized that people see a good (bad) alternative's outcome as a bad (good) sign regarding their own outcome when the two outcomes are in fact uncorrelated, a phenomenon we call the "Alternative Omen Effect" (ALOE). Subjects had to repeatedly choose between two boxes, the outcomes of which were then sequentially revealed. In Experiments 1 and 2 the alternative's outcome was presented first, and we assessed the individual's prediction of their own outcome. In Experiment 3, subjects had to predict the alternative's outcome after seeing their own. We find that even though the two outcomes were in fact uncorrelated, people tended to see a good (bad) alternative outcome as a bad (good) sign regarding their own outcome. Importantly, this illusory negative correlation affected subsequent behavior and led to irrational choices. Furthermore, the order of presentation was critical: when the outcome of the chosen option was presented first, the effect disappeared, suggesting that this illusory negative correlation is influenced by self-relevance. We discuss the possible sources of this illusory correlation as well as its implications for research on counterfactual thinking. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Tactile Radar: experimenting a computer game with visually disabled.

    PubMed

    Kastrup, Virgínia; Cassinelli, Alvaro; Quérette, Paulo; Bergstrom, Niklas; Sampaio, Eliana

    2017-09-18

    Visually disabled people increasingly use computers in everyday life, thanks to novel assistive technologies better tailored to their cognitive functioning. Like sighted people, many are interested in computer games - videogames and audio-games. Tactile-games are beginning to emerge. The Tactile Radar is a device through which a visually disabled person is able to detect distal obstacles. In this study, it is connected to a computer running a tactile-game. The game consists in finding and collecting randomly arranged coins in a virtual room. The study was conducted with nine congenital blind people including both sexes, aged 20-64 years old. Complementary methods of first and third person were used: the debriefing interview and the quasi-experimental design. The results indicate that the Tactile Radar is suitable for the creation of computer games specifically tailored for visually disabled people. Furthermore, the device seems capable of eliciting a powerful immersive experience. Methodologically speaking, this research contributes to the consolidation and development of first and third person complementary methods, particularly useful in disabled people research field, including the evaluation by users of the Tactile Radar effectiveness in a virtual reality context. Implications for rehabilitation Despite the growing interest in virtual games for visually disabled people, they still find barriers to access such games. Through the development of assistive technologies such as the Tactile Radar, applied in virtual games, we can create new opportunities for leisure, socialization and education for visually disabled people. The results of our study indicate that the Tactile Radar is adapted to the creation of video games for visually disabled people, providing a playful interaction with the players.

  17. Illusory displacement of equiluminous kinetic edges.

    PubMed

    Ramachandran, V S; Anstis, S M

    1990-01-01

    A stationary window was cut out of a stationary random-dot pattern. When a field of dots was moved continuously behind the window (a) the window appeared to move in the same direction even though it was stationary, (b) the position of the 'kinetic edges' defining the window was also displaced along the direction of dot motion, and (c) the edges of the window tended to fade on steady fixation even though the dots were still clearly visible. The illusory displacement was enhanced considerably if the kinetic edge was equiluminous and if the 'window' region was seen as 'figure' rather than 'ground'. Since the extraction of kinetic edges probably involves the use of direction-selective cells, the illusion may provide insights into how the visual system uses the output of these cells to localize the kinetic edges.

  18. Graphical tactile displays for visually-impaired people.

    PubMed

    Vidal-Verdú, Fernando; Hafez, Moustapha

    2007-03-01

    This paper presents an up-to-date survey of graphical tactile displays. These devices provide information through the sense of touch. At best, they should display both text and graphics (text may be considered a type of graphic). Graphs made with shapeable sheets result in bulky items awkward to store and transport; their production is expensive and time-consuming and they deteriorate quickly. Research is ongoing for a refreshable tactile display that acts as an output device for a computer or other information source and can present the information in text and graphics. The work in this field has branched into diverse areas, from physiological studies to technological aspects and challenges. Moreover, interest in these devices is now being shown by other fields such as virtual reality, minimally invasive surgery and teleoperation. It is attracting more and more people, research and money. Many proposals have been put forward, several of them succeeding in the task of presenting tactile information. However, most are research prototypes and very expensive to produce commercially. Thus the goal of an efficient low-cost tactile display for visually-impaired people has not yet been reached.

  19. RETENTION OF HIGH TACTILE ACUITY THROUGHOUT THE LIFESPAN IN BLINDNESS

    PubMed Central

    Legge, Gordon E.; Madison, Cindee; Vaughn, Brenna N.; Cheong, Allen M.Y.; Miller, Joseph C.

    2009-01-01

    Previous studies of tactile acuity on the fingertip using passive touch have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have re-examined this age dependence with two newly designed tactile-acuity charts requiring active exploration of the test symbols. One chart used dot patterns similar to Braille and the other used embossed Landolt rings. Groups of blind Braille readers and sighted subjects, ranging in age from 12 to 85 years, were tested in two experiments. We replicated previous findings for sighted subjects by showing an age related decrease in tactile acuity by nearly 1% per year. Surprisingly, the blind subjects retained high acuity into old age showing no age-related decline. For the blind subjects, tactile acuity did not correlate with braille reading speed, the amount of daily reading, or the age at which braille was learned. We conclude that when measured with active touch, blind subjects retain high tactile acuity into old age, unlike their aging sighted peers. We propose that blind people's use of active touch in daily activities, not specifically Braille reading, results in preservation of tactile acuity across the lifespan. PMID:19064491

  20. Blindness enhances tactile acuity and haptic 3-D shape discrimination.

    PubMed

    Norman, J Farley; Bartholomew, Ashley N

    2011-10-01

    This study compared the sensory and perceptual abilities of the blind and sighted. The 32 participants were required to perform two tasks: tactile grating orientation discrimination (to determine tactile acuity) and haptic three-dimensional (3-D) shape discrimination. The results indicated that the blind outperformed their sighted counterparts (individually matched for both age and sex) on both tactile tasks. The improvements in tactile acuity that accompanied blindness occurred for all blind groups (congenital, early, and late). However, the improvements in haptic 3-D shape discrimination only occurred for the early-onset and late-onset blindness groups; the performance of the congenitally blind was no better than that of the sighted controls. The results of the present study demonstrate that blindness does lead to an enhancement of tactile abilities, but they also suggest that early visual experience may play a role in facilitating haptic 3-D shape discrimination.

  1. Electro-tactile stimulation of the posterior neck induces body anteropulsion during upright stance.

    PubMed

    De Nunzio, A M; Yavuz, U S; Martinez-Valdes, E; Farina, D; Falla, D

    2018-05-01

    Sensory information conveyed along afferent fibers from muscle and joint proprioceptors play an important role in the control of posture and gait in humans. In particular, proprioceptive information from the neck is fundamental in supplying the central nervous system with information about the orientation and movement of the head relative to the rest of the body. The previous studies have confirmed that proprioceptive afferences originating from the neck region, evoked via muscle vibration, lead to strong body-orienting effects during static conditions (e.g., leaning of the body forwards or backwards, depending on location of vibration). However, it is not yet certain in humans, whether the somatosensory receptors located in the deep skin (cutaneous mechanoreceptors) have a substantive contribution to postural control, as vibratory stimulation encompasses the receptive field of all the somatosensory receptors from the skin to the muscles. The aim of this study was to investigate the postural effect of cutaneous mechanoreceptor afferences using electro-tactile stimulation applied to the neck. Ten healthy volunteers (8M, 2F) were evaluated. The average position of their centre of foot pressure (CoP) was acquired before, during, and after a subtle electro-tactile stimulation over their posterior neck (mean ± SD = 5.1 ± 2.3 mA at 100 Hz-140% of the perception threshold) during upright stance with their eyes closed. The electro-tactile stimulation led to a body-orienting effect with the subjects consistently leaning forward. An average shift of the CoP of 12.1 ± 11.9 mm (mean ± SD) was reported, which significantly (p < 0.05) differed from its average position under a control condition (no stimulation). These results indicate that cutaneous mechanoreceptive inflow from the neck is integrated to control stance. The findings are relevant for the exploitation of electro-tactile stimulation for rehabilitation interventions where induced

  2. Tactile directional sensibility: peripheral neural mechanisms in man.

    PubMed

    Olausson, H; Wessberg, J; Kakuda, N

    2000-06-02

    Tactile directional sensibility, i.e. the ability to tell the direction of an object's motion across the skin, is an easily observed sensory function that is highly sensitive to disturbances of the somatosensory system. Based on previous psychophysical experiments on healthy subjects it was concluded that directional sensibility depends on two kinds of information from cutaneous mechanoreceptors; spatio-temporal information and information about friction-induced changes in skin stretch. In the present study responses to similar probe movements as in the psychophysical experiments were recorded from human single mechanoreceptors in the forearm skin. All slowly adapting type 2 (SA2) units were spontaneously active, and with increasing force of friction their discharge rates were modified by probe movements at increasing distances from the Ruffini end-organ, reflecting the high stretch-sensitivity of these units. Slowly adapting type 1 (SA1) and field units responded to the moving probe within well-defined skin areas directly overlying the individual receptor terminals, and compared to the SA2 units their response properties were less dependent on the force of friction. The results suggest that SA1 and field units have the capacity to signal spatio-temporal information, whereas a population of SA2 units have the capacity to signal direction-specific information about changes in lateral skin stretch.

  3. Synthetic and Bio-Artificial Tactile Sensing: A Review

    PubMed Central

    Lucarotti, Chiara; Oddo, Calogero Maria; Vitiello, Nicola; Carrozza, Maria Chiara

    2013-01-01

    This paper reviews the state of the art of artificial tactile sensing, with a particular focus on bio-hybrid and fully-biological approaches. To this aim, the study of physiology of the human sense of touch and of the coding mechanisms of tactile information is a significant starting point, which is briefly explored in this review. Then, the progress towards the development of an artificial sense of touch are investigated. Artificial tactile sensing is analysed with respect to the possible approaches to fabricate the outer interface layer: synthetic skin versus bio-artificial skin. With particular respect to the synthetic skin approach, a brief overview is provided on various technologies and transduction principles that can be integrated beneath the skin layer. Then, the main focus moves to approaches characterized by the use of bio-artificial skin as an outer layer of the artificial sensory system. Within this design solution for the skin, bio-hybrid and fully-biological tactile sensing systems are thoroughly presented: while significant results have been reported for the development of tissue engineered skins, the development of mechanotransduction units and their integration is a recent trend that is still lagging behind, therefore requiring research efforts and investments. In the last part of the paper, application domains and perspectives of the reviewed tactile sensing technologies are discussed. PMID:23348032

  4. Comparison of measurement methods for capacitive tactile sensors and their implementation

    NASA Astrophysics Data System (ADS)

    Tarapata, Grzegorz; Sienkiewicz, Rafał

    2015-09-01

    This paper presents a review of ideas and implementations of measurement methods utilized for capacity measurements in tactile sensors. The paper describes technical method, charge amplification method, generation and as well integration method. Three selected methods were implemented in dedicated measurement system and utilised for capacitance measurements of ourselves made tactile sensors. The tactile sensors tested in this work were fully fabricated with the inkjet printing technology. The tests result were presented and summarised. The charge amplification method (CDC) was selected as the best method for the measurement of the tactile sensors.

  5. The Effects of Extravehicular Activity (EVA) Glove Pressure on Tactility

    NASA Technical Reports Server (NTRS)

    Thompson, Shelby; Miranda, Mesloh; England, Scott; Benson, Elizabeth; Rajulu, Sudhakar

    2010-01-01

    The purpose of the current study was to quantify finger tactility, while wearing a Phase VI Extravehicular Activity (EVA) glove. Subjects were fully suited in an Extravehicular Mobility Unit (EMU) suit. Data was collected under three conditions: bare-handed, gloved at 0 psi, and gloved at 4.3 psi. In order to test tactility, a series of 30 tactile stimuli (bumps) were created that varied in both height and width. With the hand obscured, subjects applied pressure to each bump until detected tactilely. The amount of force needed to detect each bump was recorded using load cells located under a force-plate. The amount of force needed to detect a bump was positively related to width, but inversely related to height. In addition, as the psi of the glove increased, more force was needed to detect the bump. In terms of application, it was possible to determine the optimal width and height a bump needs to be for a specific amount of force applied for tactility.

  6. Audio-tactile integration and the influence of musical training.

    PubMed

    Kuchenbuch, Anja; Paraskevopoulos, Evangelos; Herholz, Sibylle C; Pantev, Christo

    2014-01-01

    Perception of our environment is a multisensory experience; information from different sensory systems like the auditory, visual and tactile is constantly integrated. Complex tasks that require high temporal and spatial precision of multisensory integration put strong demands on the underlying networks but it is largely unknown how task experience shapes multisensory processing. Long-term musical training is an excellent model for brain plasticity because it shapes the human brain at functional and structural levels, affecting a network of brain areas. In the present study we used magnetoencephalography (MEG) to investigate how audio-tactile perception is integrated in the human brain and if musicians show enhancement of the corresponding activation compared to non-musicians. Using a paradigm that allowed the investigation of combined and separate auditory and tactile processing, we found a multisensory incongruency response, generated in frontal, cingulate and cerebellar regions, an auditory mismatch response generated mainly in the auditory cortex and a tactile mismatch response generated in frontal and cerebellar regions. The influence of musical training was seen in the audio-tactile as well as in the auditory condition, indicating enhanced higher-order processing in musicians, while the sources of the tactile MMN were not influenced by long-term musical training. Consistent with the predictive coding model, more basic, bottom-up sensory processing was relatively stable and less affected by expertise, whereas areas for top-down models of multisensory expectancies were modulated by training.

  7. Tactile device utilizing a single magnetorheological sponge: experimental investigation

    NASA Astrophysics Data System (ADS)

    Kim, Soomin; Kim, Pyunghwa; Choi, Seung-Hyun; Oh, Jong-Seok; Choi, Seung-Bok

    2015-04-01

    In the field of medicine, several new areas have been currently introduced such as robot-assisted surgery. However, the major drawback of these systems is that there is no tactile communication between doctors and surgical sites. When the tactile system is brought up, telemedicine including telerobotic surgery can be enhanced much more than now. In this study, a new tactile device is designed using a single magnetorhological (MR) sponge cell to realize the sensation of human organs. MR fluids and an open celled polyurethane foam are used to propose the MR sponge cell. The viscous and elastic sensational behaviors of human organs are realized by the MR sponge cell. Before developing the tactile device, tactile sensation according to touch of human fingers are quantified in advance. The finger is then treated as a reduced beam bundle model (BBM) in which the fingertip is comprised of an elastic beam virtually. Under the reduced BBM, when people want to sense an object, the fingertip is investigated by pushing and sliding. Accordingly, while several magnitudes of magnetic fields are applied to the tactile device, normal and tangential reaction forces and bending moment are measured by 6-axis force/torque sensor instead of the fingertip. These measured data are used to compare with soft tissues. It is demonstrated that the proposed MR sponge cell can realize any part of the organ based on the obtained data.

  8. Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors.

    PubMed

    Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter

    2016-08-24

    Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design.

  9. Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors

    PubMed Central

    Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter

    2016-01-01

    Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design. PMID:27563908

  10. The phase of prestimulus alpha oscillations affects tactile perception.

    PubMed

    Ai, Lei; Ro, Tony

    2014-03-01

    Previous studies have shown that neural oscillations in the 8- to 12-Hz range influence sensory perception. In the current study, we examined whether both the power and phase of these mu/alpha oscillations predict successful conscious tactile perception. Near-threshold tactile stimuli were applied to the left hand while electroencephalographic (EEG) activity was recorded over the contralateral right somatosensory cortex. We found a significant inverted U-shaped relationship between prestimulus mu/alpha power and detection rate, suggesting that there is an intermediate level of alpha power that is optimal for tactile perception. We also found a significant difference in phase angle concentration at stimulus onset that predicted whether the upcoming tactile stimulus was perceived or missed. As has been shown in the visual system, these findings suggest that these mu/alpha oscillations measured over somatosensory areas exert a strong inhibitory control on tactile perception and that pulsed inhibition by these oscillations shapes the state of brain activity necessary for conscious perception. They further suggest that these common phasic processing mechanisms across different sensory modalities and brain regions may reflect a common underlying encoding principle in perceptual processing that leads to momentary windows of perceptual awareness.

  11. Contextual cueing of tactile search is coded in an anatomical reference frame.

    PubMed

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Tactile Cueing for Target Acquisition and Identification

    DTIC Science & Technology

    2005-09-01

    method of coding tactile information, and the method of presenting elevation information were studied. Results: Subjects were divided into video game experienced...VGP) subjects and non- video game (NVGP) experienced subjects. VGPs showed a significantly lower’ target acquisition time with the 12...that video game players performed better with the highest level of tactile resolution, while non- video game players performed better with simpler pattern and a lower resolution display.

  13. Improvement and decline in tactile discrimination behavior after cortical plasticity induced by passive tactile coactivation.

    PubMed

    Hodzic, Amra; Veit, Ralf; Karim, Ahmed A; Erb, Michael; Godde, Ben

    2004-01-14

    Perceptual learning can be induced by passive tactile coactivation without attention or reinforcement. We used functional MRI (fMRI) and psychophysics to investigate in detail the specificity of this type of learning for different tactile discrimination tasks and the underlying cortical reorganization. We found that a few hours of Hebbian coactivation evoked a significant increase of primary (SI) and secondary (SII) somatosensory cortical areas representing the stimulated body parts. The amount of plastic changes was strongly correlated with improvement in spatial discrimination performance. However, in the same subjects, frequency discrimination was impaired after coactivation, indicating that even maladaptive processes can be induced by intense passive sensory stimulation.

  14. Cooperative processing in primary somatosensory cortex and posterior parietal cortex during tactile working memory.

    PubMed

    Ku, Yixuan; Zhao, Di; Bodner, Mark; Zhou, Yong-Di

    2015-08-01

    In the present study, causal roles of both the primary somatosensory cortex (SI) and the posterior parietal cortex (PPC) were investigated in a tactile unimodal working memory (WM) task. Individual magnetic resonance imaging-based single-pulse transcranial magnetic stimulation (spTMS) was applied, respectively, to the left SI (ipsilateral to tactile stimuli), right SI (contralateral to tactile stimuli) and right PPC (contralateral to tactile stimuli), while human participants were performing a tactile-tactile unimodal delayed matching-to-sample task. The time points of spTMS were 300, 600 and 900 ms after the onset of the tactile sample stimulus (duration: 200 ms). Compared with ipsilateral SI, application of spTMS over either contralateral SI or contralateral PPC at those time points significantly impaired the accuracy of task performance. Meanwhile, the deterioration in accuracy did not vary with the stimulating time points. Together, these results indicate that the tactile information is processed cooperatively by SI and PPC in the same hemisphere, starting from the early delay of the tactile unimodal WM task. This pattern of processing of tactile information is different from the pattern in tactile-visual cross-modal WM. In a tactile-visual cross-modal WM task, SI and PPC contribute to the processing sequentially, suggesting a process of sensory information transfer during the early delay between modalities. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  15. Seeing the body distorts tactile size perception.

    PubMed

    Longo, Matthew R; Sadibolova, Renata

    2013-03-01

    Vision of the body modulates somatosensation, even when entirely non-informative about stimulation. For example, seeing the body increases tactile spatial acuity, but reduces acute pain. While previous results demonstrate that vision of the body modulates somatosensory sensitivity, it is unknown whether vision also affects metric properties of touch, and if so how. This study investigated how non-informative vision of the body modulates tactile size perception. We used the mirror box illusion to induce the illusion that participants were directly seeing their stimulated left hand, though they actually saw their reflected right hand. We manipulated whether participants: (a) had the illusion of directly seeing their stimulated left hand, (b) had the illusion of seeing a non-body object at the same location, or (c) looked directly at their non-stimulated right-hand. Participants made verbal estimates of the perceived distance between two tactile stimuli presented simultaneously to the dorsum of the left hand, either 20, 30, or 40mm apart. Vision of the body significantly reduced the perceived size of touch, compared to vision of the object or of the contralateral hand. In contrast, no apparent changes of perceived hand size were found. These results show that seeing the body distorts tactile size perception. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Re-examining overlap between tactile and visual motion responses within hMT+ and STS

    PubMed Central

    Jiang, Fang; Beauchamp, Michael S.; Fine, Ione

    2015-01-01

    Here we examine overlap between tactile and visual motion BOLD responses within the human MT+ complex. Although several studies have reported tactile responses overlapping with hMT+, many used group average analyses, leaving it unclear whether these responses were restricted to sub-regions of hMT+. Moreover, previous studies either employed a tactile task or passive stimulation, leaving it unclear whether or not tactile responses in hMT+ are simply the consequence of visual imagery. Here we carried out a replication of one of the classic papers finding tactile responses in hMT+ (Hagen et al. 2002). We mapped MT and MST in individual subjects using visual field localizers. We then examined responses to tactile motion on the arm, either presented passively or in the presence of a visual task performed at fixation designed to minimize visualization of the concurrent tactile stimulation. To our surprise, without a visual task, we found only weak tactile motion responses in MT (6% of voxels showing tactile responses) and MST (2% of voxels). With an unrelated visual task designed to withdraw attention from the tactile modality, responses in MST reduced to almost nothing (<1% regions). Consistent with previous results, we did observe tactile responses in STS regions superior and anterior to hMT+. Despite the lack of individual overlap, group averaged responses produced strong spurious overlap between tactile and visual motion responses within hMT+ that resembled those observed in previous studies. The weak nature of tactile responses in hMT+ (and their abolition by withdrawal of attention) suggests that hMT+ may not serve as a supramodal motion processing module. PMID:26123373

  17. A preliminary investigation of lumbar tactile acuity in yoga practitioners.

    PubMed

    Flaherty, Mary; Connolly, Martin

    2014-01-01

    Tactile acuity in the back relates to voluntary lumbo-pelvic control and is lower in chronic low back pain (CLBP) patients. Two-point discrimination (TPD) thresholds are higher, indicating decreased tactile acuity in patients with CLBP. Yoga has been shown to help relieve CLBP. This study investigated the hypothesis that regular practitioners of yoga have increased tactile acuity (i.e., lower TPD thresholds) when compared to matched controls who regularly perform gym-based (resistance training or aerobic-type) exercise. Tactile acuity in the low back was assessed using TPD in 16 long-term practitioners of yoga (5 Ashtanga, 5 Bikram, and 6 Iyengar practitioners) and 16 age- and gender-matched healthy controls who exercise (with weights and aerobic exercise). The yoga practitioners' TPD was lower than that of the exercisers, indicating greater tactile acuity in the low back. While there was no difference between the TPD of the practitioners of different yoga styles, the TPD of the Ashtanga yoga participants were significantly lower than those of the exercisers. The yogis whose main reasons to practice yoga were for "meditation or increased mindfulness" and for "well-being" showed a nonsignificant trend of higher tactile acuity than those who did yoga for "physical exercise." There was no association between TPD threshold and cumulative amount of yoga practice in terms of hours per week and years of experience. However, increased hours of exercise per week correlated with higher TPD. The findings suggest that there may be a relationship between yoga practice and enhanced tactile acuity in the low back.

  18. Inert gas narcosis has no influence on thermo-tactile sensation.

    PubMed

    Jakovljević, Miroljub; Vidmar, Gaj; Mekjavic, Igor B

    2012-05-01

    Contribution of skin thermal sensors under inert gas narcosis to the raising hypothermia is not known. Such information is vital for understanding the impact of narcosis on behavioural thermoregulation, diver safety and judgment of thermal (dis)comfort in the hyperbaric environment. So this study aimed at establishing the effects of normoxic concentration of 30% nitrous oxide (N(2)O) on thermo-tactile threshold sensation by studying 16 subjects [eight females and eight males; eight sensitive (S) and eight non-sensitive (NS) to N(2)O]. Their mean (SD) age was 22.1 (1.8) years, weight 72.8 (15.3) kg, height 1.75 (0.10) m and body mass index 23.8 (3.8) kg m(-2). Quantitative thermo-tactile sensory testing was performed on forearm, upper arm and thigh under two experimental conditions: breathing air (air trial) and breathing normoxic mixture of 30% N(2)O (N(2)O trial) in the mixed sequence. Difference in thermo-tactile sensitivity thresholds between two groups of subjects in two experimental conditions was analysed by 3-way mixed-model analysis of covariance. There were no statistically significant differences in thermo-tactile thresholds either between the Air and N(2)O trials, or between S and NS groups, or between females and males, or with respect to body mass index. Some clinically insignificant lowering of thermo-tactile thresholds occurred only for warm thermo-tactile thresholds on upper arm and thigh. The results indicated that normoxic mixture of 30% N(2)O had no influence on thermo-tactile sensation in normothermia.

  19. Development of tactile sensory circuits in the CNS.

    PubMed

    Iwasato, Takuji; Erzurumlu, Reha S

    2018-06-13

    Molecular identification of neuronal types and genetic and imaging approaches to characterize their properties reveal morphological, physiological and dynamic aspects of sensory circuit development. Here we focus on the mouse tactile sensory circuitry, with particular emphasis on the main trigeminal pathway that connects the whiskers, the major tactile organ in rodents, to the neocortex. At each level of this pathway, neurogenesis, axonal elongation, pathfinding, target recognition and circuit reorganization including dendritic refinement of cortical layer 4 neurons occur contemporaneously and a multitude of molecular signals are used in differing combinations. We highlight recent advances in development of tactile circuitry and note gaps in our understanding. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Prototype tactile feedback system for examination by skin touch.

    PubMed

    Lee, O; Lee, K; Oh, C; Kim, K; Kim, M

    2014-08-01

    Diagnosis of conditions such as psoriasis and atopic dermatitis, in the case of induration, involves palpating the infected area via hands and then selecting a ratings score. However, the score is determined based on the tester's experience and standards, making it subjective. To provide tactile feedback on the skin, we developed a prototype tactile feedback system to simulate skin wrinkles with PHANToM OMNI. To provide the user with tactile feedback on skin wrinkles, a visual and haptic Augmented Reality system was developed. First, a pair of stereo skin images obtained by a stereo camera generates a disparity map of skin wrinkles. Second, the generated disparity map is sent to an implemented tactile rendering algorithm that computes a reaction force according to the user's interaction with the skin image. We first obtained a stereo image of skin wrinkles from the in vivo stereo imaging system, which has a baseline of 50.8 μm, and obtained the disparity map with a graph cuts algorithm. The left image is displayed on the monitor to enable the user to recognize the location visually. The disparity map of the skin wrinkle image sends skin wrinkle information as a tactile response to the user through a haptic device. We successfully developed a tactile feedback system for virtual skin wrinkle simulation by means of a commercialized haptic device that provides the user with a single point of contact to feel the surface roughness of a virtual skin sample. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Sensorimotor aspects of high-speed artificial gravity: II. The effect of head position on illusory self motion

    NASA Technical Reports Server (NTRS)

    Mast, F. W.; Newby, N. J.; Young, L. R.

    2002-01-01

    The effects of cross-coupled stimuli on the semicircular canals are shown to be influenced by the position of the subject's head with respect to gravity and the axis of rotation, but not by the subject's head position relative to the trunk. Seventeen healthy subjects made head yaw movements out of the horizontal plane while lying on a horizontal platform (MIT short radius centrifuge) rotating at 23 rpm about an earth-vertical axis. The subjects reported the magnitude and duration of the illusory pitch or roll sensations elicited by the cross-coupled rotational stimuli acting on the semicircular canals. The results suggest an influence of head position relative to gravity. The magnitude estimation is higher and the sensation decays more slowly when the head's final position is toward nose-up (gravity in the subject's head x-z-plane) compared to when the head is turned toward the side (gravity in the subject's head y-z-plane). The results are discussed with respect to artificial gravity in space and the possible role of pre-adaptation to cross-coupled angular accelerations on earth.

  2. Nitrogen narcosis and tactile shape memory in low visibility.

    PubMed

    van Wijk, Charles H; Meintjes, W A J

    2014-01-01

    Commercial diving often occurs in low visibility, where divers are reliant on their tactile senses. This study examined the effect of nitrogen narcosis on tactile memory for shapes as well as the influence of psychological and biographical factors on this relationship. This crossover study tested 139 commercial divers in a dry hyperbaric chamber at 101.325 and 607.95 kPa (1 and 6 atmospheres absolute/atm abs). Divers memorized shapes while blindfolded, using their tactile senses only. Delayed recall was measured at the surface after each dive. Psychological and biographical data were also collected. A significant effect of hyperbaric pressure on tactile memory was demonstrated, and a further effect of sequence of testing found. Thus, divers' delayed shape recall deteriorated by 8% after learning material at depth, compared to learning on the surface. There were also significant but small effects of psychological and biographical markers on tactile memory performance, with lower trait anxiety associated with better recall, and lower education associated with poorer recall. The findings emphasize the importance of utilizing other forms of recording of events or objects at depth, particularly in conditions of low visibility during deeper diving, to aid memory encoding and subsequent recall at the surface.

  3. Meet our Neighbours - a tactile experience

    NASA Astrophysics Data System (ADS)

    Canas, L.; Lobo Correia, A.

    2013-09-01

    Planetary science is a key field in astronomy that draws lots of attention and that engages large amounts of enthusiasts. On its essence, it is a visual science and the current resources and activities for the inclusion of visually impaired children, although increasing, are still costly and somewhat scarce. Therefore there is a paramount need to develop more low cost resources in order to provide experiences that can reach all, even the more socially deprived communities. "Meet our neighbours!-a tactile experience", plans to promote and provide inclusion activities for visually impaired children and their non-visually impaired peers through the use of astronomy hands-on low cost activities. Is aimed for children from the ages of 6 to 12 years old and produce data set 13 tactile images of the main objects of the Solar System that can be used in schools, science centres and outreach associations. Accessing several common problems through tactile resources, with this project we present ways to successfully provide low cost solutions (avoiding the expensive tactile printing costs), promote inclusion and interactive hands-on activities for visually impaired children and their non-visually impaired peers and create dynamic interactions based on oral knowledge transmission between them. Here we describe the process of implementing such initiative near target communities: establishing a bridge between scientists, children and teachers. The struggles and challenges perceived during the project and the enrichment experience of engaging astronomy with these specific groups, broadening horizons in an overall experience accessible to all.

  4. Evolutionary Specialization of Tactile Perception in Vertebrates.

    PubMed

    Schneider, Eve R; Gracheva, Elena O; Bagriantsev, Slav N

    2016-05-01

    Evolution has endowed vertebrates with the remarkable tactile ability to explore the world through the perception of physical force. Yet the sense of touch remains one of the least well understood senses at the cellular and molecular level. Vertebrates specializing in tactile perception can highlight general principles of mechanotransduction. Here, we review cellular and molecular adaptations that underlie the sense of touch in typical and acutely mechanosensitive vertebrates. ©2016 Int. Union Physiol. Sci./Am. Physiol. Soc.

  5. Braille in the Sighted: Teaching Tactile Reading to Sighted Adults.

    PubMed

    Bola, Łukasz; Siuda-Krzywicka, Katarzyna; Paplińska, Małgorzata; Sumera, Ewa; Hańczur, Paweł; Szwed, Marcin

    2016-01-01

    Blind people are known to have superior perceptual abilities in their remaining senses. Several studies suggest that these enhancements are dependent on the specific experience of blind individuals, who use those remaining senses more than sighted subjects. In line with this view, sighted subjects, when trained, are able to significantly progress in relatively simple tactile tasks. However, the case of complex tactile tasks is less obvious, as some studies suggest that visual deprivation itself could confer large advantages in learning them. It remains unclear to what extent those complex skills, such as braille reading, can be learnt by sighted subjects. Here we enrolled twenty-nine sighted adults, mostly braille teachers and educators, in a 9-month braille reading course. At the beginning of the course, all subjects were naive in tactile braille reading. After the course, almost all were able to read whole braille words at a mean speed of 6 words-per-minute. Subjects with low tactile acuity did not differ significantly in braille reading speed from the rest of the group, indicating that low tactile acuity is not a limiting factor for learning braille, at least at this early stage of learning. Our study shows that most sighted adults can learn whole-word braille reading, given the right method and a considerable amount of motivation. The adult sensorimotor system can thus adapt, to some level, to very complex tactile tasks without visual deprivation. The pace of learning in our group was comparable to congenitally and early blind children learning braille in primary school, which suggests that the blind's mastery of complex tactile tasks can, to a large extent, be explained by experience-dependent mechanisms.

  6. Braille in the Sighted: Teaching Tactile Reading to Sighted Adults

    PubMed Central

    Bola, Łukasz; Siuda-Krzywicka, Katarzyna; Paplińska, Małgorzata; Sumera, Ewa; Hańczur, Paweł; Szwed, Marcin

    2016-01-01

    Blind people are known to have superior perceptual abilities in their remaining senses. Several studies suggest that these enhancements are dependent on the specific experience of blind individuals, who use those remaining senses more than sighted subjects. In line with this view, sighted subjects, when trained, are able to significantly progress in relatively simple tactile tasks. However, the case of complex tactile tasks is less obvious, as some studies suggest that visual deprivation itself could confer large advantages in learning them. It remains unclear to what extent those complex skills, such as braille reading, can be learnt by sighted subjects. Here we enrolled twenty-nine sighted adults, mostly braille teachers and educators, in a 9-month braille reading course. At the beginning of the course, all subjects were naive in tactile braille reading. After the course, almost all were able to read whole braille words at a mean speed of 6 words-per-minute. Subjects with low tactile acuity did not differ significantly in braille reading speed from the rest of the group, indicating that low tactile acuity is not a limiting factor for learning braille, at least at this early stage of learning. Our study shows that most sighted adults can learn whole-word braille reading, given the right method and a considerable amount of motivation. The adult sensorimotor system can thus adapt, to some level, to very complex tactile tasks without visual deprivation. The pace of learning in our group was comparable to congenitally and early blind children learning braille in primary school, which suggests that the blind’s mastery of complex tactile tasks can, to a large extent, be explained by experience-dependent mechanisms. PMID:27187496

  7. Merkel disc is a serotonergic synapse in the epidermis for transmitting tactile signals in mammals.

    PubMed

    Chang, Weipang; Kanda, Hirosato; Ikeda, Ryo; Ling, Jennifer; DeBerry, Jennifer J; Gu, Jianguo G

    2016-09-13

    The evolution of sensory systems has let mammals develop complicated tactile end organs to enable sophisticated sensory tasks, including social interaction, environmental exploration, and tactile discrimination. The Merkel disc, a main type of tactile end organ consisting of Merkel cells (MCs) and Aβ-afferent endings, are highly abundant in fingertips, touch domes, and whisker hair follicles of mammals. The Merkel disc has high tactile acuity for an object's physical features, such as texture, shape, and edges. Mechanisms underlying the tactile function of Merkel discs are obscured as to how MCs transmit tactile signals to Aβ-afferent endings leading to tactile sensations. Using mouse whisker hair follicles, we show herein that tactile stimuli are transduced by MCs into excitatory signals that trigger vesicular serotonin release from MCs. We identify that both ionotropic and metabotropic 5-hydroxytryptamine (5-HT) receptors are expressed on whisker Aβ-afferent endings and that their activation by serotonin released from MCs initiates Aβ-afferent impulses. Moreover, we demonstrate that these ionotropic and metabotropic 5-HT receptors have a synergistic effect that is critical to both electrophysiological and behavioral tactile responses. These findings elucidate that the Merkel disc is a unique serotonergic synapse located in the epidermis and plays a key role in tactile transmission. The epidermal serotonergic synapse may have important clinical implications in sensory dysfunctions, such as the loss of tactile sensitivity and tactile allodynia seen in patients who have diabetes, inflammatory diseases, and undergo chemotherapy. It may also have implications in the exaggerated tactile sensations induced by recreational drugs that act on serotoninergic synapses.

  8. Tactile display device using an electrorheological fluid

    NASA Technical Reports Server (NTRS)

    Garner, H. Douglas (Inventor)

    1994-01-01

    A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

  9. Where are my hands? Influence of limb posture on tactile extinction.

    PubMed

    Auclair, Laurent; Barra, Julien; Raibaut, Patrick

    2012-05-01

    Tactile localization on the skin involves both a somatotopic and a postural schema (body-schema) representation. The present study determines the extent to which body posture influences tactile perception in right-brain-damaged patients. In a first set of experiments, patients were asked to detect single tactile stimulation delivered to their left or right hands or to both hands simultaneously (double stimulation) in different arm postures. Only patients who had no difficulty localizing single and double tactile stimulations when their hands were placed in anatomic position were tested. Participant's hands were crossed, one over the other, and the tactile stimuli were delivered either to the hand (beyond the crossing point, Experiment 1) or to the forearm (before the crossing point, Experiment 2). In Experiment 3, the left hand was placed in the right hemispace and the right hand in the left hemispace without crossing over (opposite condition). In a second set of experiments, patients were asked to detect stimulation delivered to the forefinger. The fingers were crossed, one over the other at the level of the middle phalanx, and stimuli were delivered either beyond or before the crossing point. In all experimental conditions, control participants performed at ceiling. We observed a left-hand tactile extinction on double stimulation in the crossed condition. These results suggest that tactile stimuli can be encoded based on multiple specific body-part representations rather than on an integrated body-schema representation.

  10. Tapered whiskers are required for active tactile sensation.

    PubMed

    Hires, Samuel Andrew; Pammer, Lorenz; Svoboda, Karel; Golomb, David

    2013-11-19

    Many mammals forage and burrow in dark constrained spaces. Touch through facial whiskers is important during these activities, but the close quarters makes whisker deployment challenging. The diverse shapes of facial whiskers reflect distinct ecological niches. Rodent whiskers are conical, often with a remarkably linear taper. Here we use theoretical and experimental methods to analyze interactions of mouse whiskers with objects. When pushed into objects, conical whiskers suddenly slip at a critical angle. In contrast, cylindrical whiskers do not slip for biologically plausible movements. Conical whiskers sweep across objects and textures in characteristic sequences of brief sticks and slips, which provide information about the tactile world. In contrast, cylindrical whiskers stick and remain stuck, even when sweeping across fine textures. Thus the conical whisker structure is adaptive for sensor mobility in constrained environments and in feature extraction during active haptic exploration of objects and surfaces. DOI: http://dx.doi.org/10.7554/eLife.01350.001.

  11. Tactile Acuity Charts: A Reliable Measure of Spatial Acuity

    PubMed Central

    Bruns, Patrick; Camargo, Carlos J.; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R.; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds. PMID:24504346

  12. Attentional Modulation of Somatosensory Processing During the Anticipation of Movements Accompanying Pain: An Event-Related Potential Study.

    PubMed

    Clauwaert, Amanda; Torta, Diana M; Danneels, Lieven; Van Damme, Stefaan

    2018-02-01

    Attending to pain-relevant information is crucial to protect us from physical harm. Behavioral studies have already suggested that during anticipation of pain somatosensory input at the body location under threat is prioritized. However, research using daily life cues for pain, especially movements, is lacking. Furthermore, to our knowledge, no studies have investigated cortical processing associated with somatosensory processing during threatened movements. The current study aims to investigate whether movements accompanying pain automatically steer attention toward somatosensory input at the threatened location, affecting somatosensory evoked potentials (SEPs). Healthy volunteers were cued to perform movements with the left or the right hand, and one of these movements could be accompanied by pain on the moving hand. During movement anticipation, a task-irrelevant tactile stimulus was presented to the threatened or pain-free hand to evoke SEPs. During anticipation of movements accompanying pain, the N120 component was increased for tactile stimuli at the threatened relative to the hand without pain. Moreover, the P200 SEP was enhanced during anticipation of movements accompanying pain relative to movements without pain, irrespective of which hand was stimulated. These findings show that the anticipation of pain-accompanying movements may affect the processing of somatosensory input, and that this is likely to be driven by attentional processes. This study shows that the anticipation of pain-related movements automatically biases attention toward stimuli at a pain-related location, measured according to SEPs. The present study provides important new insights in the interplay between pain and attention, and its consequences at the cortical level. Copyright © 2017 The American Pain Society. Published by Elsevier Inc. All rights reserved.

  13. Force/torque and tactile sensors for sensor-based manipulator control

    NASA Technical Reports Server (NTRS)

    Vanbrussel, H.; Belieen, H.; Bao, Chao-Ying

    1989-01-01

    The autonomy of manipulators, in space and in industrial environments, can be dramatically enhanced by the use of force/torque and tactile sensors. The development and future use of a six-component force/torque sensor for the Hermes Robot Arm (HERA) Basic End-Effector (BEE) is discussed. Then a multifunctional gripper system based on tactile sensors is described. The basic transducing element of the sensor is a sheet of pressure-sensitive polymer. Tactile image processing algorithms for slip detection, object position estimation, and object recognition are described.

  14. Resonant vibrating sensors for tactile tissue differentiation

    NASA Astrophysics Data System (ADS)

    Hemsel, T.; Stroop, R.; Oliva Uribe, D.; Wallaschek, J.

    2007-12-01

    Surgical resection of brain tumours is a difficult task. To enhance surgery results, a tactile sensor is wanted that gives better resolution and sensitivity than the human tactile sense. The characteristics of resonant vibrating piezoelectric elements change with varying load. This allows for calculation of mechanical load parameters by measuring electrical quantities. Different setups of piezoelectric sensors have been used to investigate soft materials. Finally, a piezoelectric bimorph sensor gave good results for distinguishing tissue mimicking gel-phantoms with different gelatine concentrations.

  15. Scalable fabric tactile sensor arrays for soft bodies

    NASA Astrophysics Data System (ADS)

    Day, Nathan; Penaloza, Jimmy; Santos, Veronica J.; Killpack, Marc D.

    2018-06-01

    Soft robots have the potential to transform the way robots interact with their environment. This is due to their low inertia and inherent ability to more safely interact with the world without damaging themselves or the people around them. However, existing sensing for soft robots has at least partially limited their ability to control interactions with their environment. Tactile sensors could enable soft robots to sense interaction, but most tactile sensors are made from rigid substrates and are not well suited to applications for soft robots which can deform. In addition, the benefit of being able to cheaply manufacture soft robots may be lost if the tactile sensors that cover them are expensive and their resolution does not scale well for manufacturability. This paper discusses the development of a method to make affordable, high-resolution, tactile sensor arrays (manufactured in rows and columns) that can be used for sensorizing soft robots and other soft bodies. However, the construction results in a sensor array that exhibits significant amounts of cross-talk when two taxels in the same row are compressed. Using the same fabric-based tactile sensor array construction design, two different methods for cross-talk compensation are presented. The first uses a mathematical model to calculate a change in resistance of each taxel directly. The second method introduces additional simple circuit components that enable us to isolate each taxel electrically and relate voltage to force directly. Fabric sensor arrays are demonstrated for two different soft-bodied applications: an inflatable single link robot and a human wrist.

  16. A comparison of colour, shape, and flash induced illusory line motion.

    PubMed

    Hamm, Jeff P

    2017-04-01

    When a bar suddenly appears between two boxes, the bar will appear to shoot away from the box that matches it in colour or in shape-a phenomenon referred to as attribute priming of illusory line motion (ILM; colour ILM and shape ILM, respectively). If the two boxes are identical, ILM will still occur away from a box if it changes luminance shortly before the presentation of the bar ( flash ILM). This flash condition has been suggested to produce the illusory motion due to the formation of an attentional gradient surrounding the flashed location. However, colour ILM and shape ILM cannot be explained by an attentional gradient as there is no way for attention to select the matching box prior to the presentation of the bar. These findings challenge the attentional gradient explanation for ILM, but only if it is assumed that ILM arises for the same underlying reason. Two experiments are presented that address the question of whether or not flash ILM is the same as colour ILM or shape ILM. The results suggest that while colour ILM and shape ILM reflect a common illusion, flash ILM arises for a different reason. Therefore, the attentional gradient explanation for flash ILM is not refuted by the occurrence of colour ILM or shape ILM, which may reflect transformational apparent motion (TAM).

  17. Nano opto-mechanical systems (NOMS) as a proposal for tactile displays

    NASA Astrophysics Data System (ADS)

    Campo, E. M.; Roig, J.; Roeder, B.; Wenn, D.; Mamojka, B.; Omastova, M.; Terentjev, E. M.; Esteve, J.

    2011-10-01

    For over a decade, special emphasis has been placed in the convergence of different fields of science and technology, in an effort to serve human needs by way of enhancing human capabilities. The convergence of the Nano-Bio-Info-Cogni (NBIC) quartet will provide unique solutions to specific needs. This is the case of, Nano-opto mechanical Systems (NOMS), presented as a solution to tactile perception, both for the visually-impaired and for the general public. NOMS, based on photoactive polymer actuators and devices, is a much sought-after technology. In this scheme, light sources promote mechanical actuation producing a variety of nano-opto mechanical systems such as nano-grippers. In this paper, we will provide a series of specifications that the NOMS team is targeting towards the development of a tactile display using optically-activated smart materials. Indeed, tactile displays remain mainly mechanical, compromising reload speeds and resolution which inhibit 3D tactile representation of web interfaces. We will also discuss how advantageous NOMS tactile displays could be for the general public. Tactile processing based on stimulation delivered through the NOMS tablet, will be tested using neuropsychology methods, in particular event-related brain potentials. Additionally, the NOMS tablet will be instrumental to the development of basic neuroscience research.

  18. Learning in Tactile Channels

    ERIC Educational Resources Information Center

    Gescheider, George A.; Wright, John H.

    2012-01-01

    Vibrotactile intensity-discrimination thresholds for sinusoidal stimuli applied to the thenar eminence of the hand declined as a function of practice. However, improvement was confined to the tactile information-processing channel in which learning had occurred. Specifically, improvements in performance with training within the Pacinian-corpuscle…

  19. Can tactile sensory processing differentiate between children with autistic disorder and asperger's disorder?

    PubMed

    Ghanizadeh, Ahmad

    2011-05-01

    There are debates whether autistic disorder (autism) and Asperger's disorder are two distinct disorders. Moreover, interventional sensory occupational therapy should consider the clinical characteristics of patients. Already, commonalities and differences between Asperger's disorder and autistic disorder are not well studied. The aim of this study is to compare tactile sensory function of children with autistic disorder and children with Asperger's disorder. Tactile sensory function was compared between 36 children with autism and 19 children with Asperger's disorder. The two disorders were diagnosed based on Diagnostic and Statistical Manual of Mental Disorders Fourth Edition, Text Revision. The parent-reported Tactile Dysfunction Checklist was used to assess the three aspects of hypersensitivity, hyposensitivity, and poor tactile perception and discrimination. Developmental coordination was also assessed. Developmental coordination problems total score was not associated with group. The mean (standard deviation) score of tactile hyper-responsivity was not different between the groups. Tactile hyporesponsivity and poor tactile perception and discrimination scores were statistically higher in autistic disorder than Asperger's disorder group. These results for the first time indicated that at least some aspects of tactile perception can differentiate these two disorders. Children with autistic disorder have more tactile sensory seeking behaviors than children with Asperger's disorder. Moreover, the ability of children with autistic disorder for tactile discrimination and sensory perception is less than those with Asperger's disorder. Interventional sensory therapy in children with autistic disorder should have some characteristics that can be different and specific for children with Asperger's disorder. Formal intelligence quotient testing was not performed on all of the children evaluated, which is a limitation to this study. In some cases, a clinical estimation of

  20. Effect of stationary objects on illusory forward self-motion induced by a looming display.

    PubMed

    Ohmi, M; Howard, I P

    1988-01-01

    It has previously been shown that when a moving and a stationary display are superimposed, illusory self-rotation (circular vection) is induced only when the moving display appears as the background. Three experiments are reported on the extent to which illusory forward self-motion (forward vection) induced by a looming display is inhibited by a superimposed stationary display as a function of the size and location of the stationary display and of the depth between the stationary and looming displays. Results showed that forward vection was controlled by the display that was perceived as the background, and background stationary displays suppressed forward vection by about the same amount whatever their size and eccentricity. Also, the perception of foreground-background properties of competing displays determined which controlled forward vection, and this control was not tied to specific depth cues. The inhibitory effect of a stationary background on forward vection was, however, weaker than that found with circular vection. This difference makes sense because, for forward body motion, the image of a distant scene is virtually stationary whereas, when the body rotates, it is not.

  1. A reconfigurable tactile display based on polymer MEMS technology

    NASA Astrophysics Data System (ADS)

    Wu, Xiaosong

    A tactile display provides information such as shape, texture, temperature, and hardness to a user. Ultimately, a tactile display could be used to recreate a virtual object that may be stored in a computer. However, such advanced displays are not yet widely available, primarily due to the lack of low cost, large area, compact actuator arrays that can stimulate the large numbers of receptors of the user and that can also meet the high requirements for user safety and comfort. This research focuses on the development of polymer microfabrication technologies for the realization of two major components of a pneumatic tactile display: a microactuator array and a complementary microvalve (control) array. In this work, the concept, fabrication, and characterization of a kinematically-stabilized polymeric microbubble actuator ("endoskeletal microbubble actuator") is presented. A systematic design and modeling procedure was carried out to generate an optimized geometry of the corrugated diaphragm to satisfy membrane deflection, force, and stability requirements set forth by the tactile display goals. A mass-manufacturable actuator has been fabricated using the approaches of lithography and micromolding. A prototype of a single endoskeletal bubble actuator with a diameter of 2.6mm has been fabricated and characterized. In addition, in order to further reduce the size and cost of the tactile display, a microvalve array can be integrated into the tactile display system to control the pneumatic fluid that actuates the microbubble actuator. A piezoelectrically-driven and hydraulically-amplified polymer microvalve has been designed, fabricated, and tested. An incompressible elastomer was used as a solid hydraulic medium to convert the small axial displacement of a piezoelectric actuator into a large valve head stroke while maintaining a large blocking force. The function of the microvalve as an on-off switch for a pneumatic microbubble tactile actuator has been demonstrated

  2. Development of a tactile display with 5 mm resolution using an array of magnetorheological fluid

    NASA Astrophysics Data System (ADS)

    Ishizuka, Hiroki; Miki, Norihisa

    2017-06-01

    In this study, we demonstrate the design and evaluation of a stiffness tactile display using a magnetorheological (MR) fluid. The tactile display is based on the change in mechanical properties under an external magnetic field. In the tactile display, the MR fluid is encapsulated in chambers of 3 mm diameter and arranged at intervals of 2 mm. Magnetic fields were spatially applied to the tactile display using neodymium magnets of 3.5 mm diameter. The design and spatial magnetic field application enable the tactile display to present stiff dots of 5 mm resolution. We confirmed that the tactile display can present a spatial stiff dot and its pattern on the surface by compression experiments. Sensory evaluation revealed that the users were able to perceive the approximate position of the stiff dots. From the experiments, the tactile display has potential as a palpation tactile display and requires improvement to present various types of tissues.

  3. E-Pad: a comfortable electrocutaneous-based tactile feedback display

    NASA Astrophysics Data System (ADS)

    Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi

    2018-01-01

    The devices with touchscreen are becoming more popular recently; however, most of them suffer from the crucial drawbacks of lacking accurate tactile feedback. A novel electrocutaneous-based tactile device with the name of E-pad is proposed to provide a dynamic and static low-voltage feedback for touchscreen. We optimize the key parameters of the output voltage and design custom-made hardwares to guarantee a comfortable user experience. Users could move their fingers freely across the touchscreen of the proposed device to really feel virtual objects. Two preliminary experiments are conducted to evaluate the interactive performance of the proposed device and the experimental results show that the proposed device can provide a comfortable and distinct tactile feedback.

  4. The spiral aftereffect : influence of stimulus size and viewing distance on the duration of illusory motion.

    DOT National Transportation Integrated Search

    1968-05-01

    The study examined some effects of stimulus size and distance on the persistence of one type of illusory motion, viz., the spiral aftereffect (SAE). Duration of SAE was investigated with stimuli of 2, 4, 8, 12, and 16 inches in diameter. The distance...

  5. Effects of passive and active movement on vibrotactile detection thresholds of the Pacinian channel and forward masking.

    PubMed

    Yıldız, Mustafa Z; Toker, İpek; Özkan, Fatma B; Güçlü, Burak

    2015-01-01

    We investigated the gating effect of passive and active movement on the vibrotactile detection thresholds of the Pacinian (P) psychophysical channel and forward masking. Previous work on gating mostly used electrocutaneous stimulation and did not allow focusing on tactile submodalities. Ten healthy adults participated in our study. Passive movement was achieved by swinging a platform, on which the participant's stimulated hand was attached, manually by a trained operator. The root-mean-square value of the movement speed was kept in a narrow range (slow: 10-20 cm/s, fast: 50-60 cm/s). Active movement was performed by the participant him-/herself using the same apparatus. The tactile stimuli consisted of 250-Hz sinusoidal mechanical vibrations, which were generated by a shaker mounted on the movement platform and applied to the middle fingertip. In the forward-masking experiments, a high-level masking stimulus preceded the test stimulus. Each movement condition was tested separately in a two-interval forced-choice detection task. Both passive and active movement caused a robust gating effect, that is, elevation of thresholds, in the fast speed range. Statistically significant change of thresholds was not found in slow movement conditions. Passive movement yielded higher thresholds than those measured during active movement, but this could not be confirmed statistically. On the other hand, the effect of forward masking was approximately constant as the movement condition varied. These results imply that gating depends on both peripheral and central factors in the P channel. Active movement may have some facilitatory role and produce less gating. Additionally, the results support the hypothesis regarding a critical speed for gating, which may be relevant for daily situations involving vibrations transmitted through grasped objects and for manual exploration.

  6. Tactile Sensitivity of Children: Effects of Frequency, Masking, and the Non-Pacinian I Psychophysical Channel

    ERIC Educational Resources Information Center

    Guclu, Burak; Oztek, Cigdem

    2007-01-01

    Tactile perception depends on the contributions of four psychophysical tactile channels mediated by four corresponding receptor systems. The sensitivity of the tactile channels is determined by detection thresholds that vary as a function of the stimulus frequency. It has been widely reported that tactile thresholds increase (i.e., sensitivity…

  7. Change of reference frame for tactile localization during child development.

    PubMed

    Pagel, Birthe; Heed, Tobias; Röder, Brigitte

    2009-11-01

    Temporal order judgements (TOJ) for two tactile stimuli, one presented to the left and one to the right hand, are less precise when the hands are crossed over the midline than when the hands are uncrossed. This 'crossed hand' effect has been considered as evidence for a remapping of tactile input into an external reference frame. Since late, but not early, blind individuals show such remapping, it has been hypothesized that the use of an external reference frame develops during childhood. Five- to 10-year-old children were therefore tested with the tactile TOJ task, both with uncrossed and crossed hands. Overall performance in the TOJ task improved with age. While children older than 5 1/2 years displayed a crossed hand effect, younger children did not. Therefore the use of an external reference frame for tactile, and possibly multisensory, localization seems to be acquired at age 5.

  8. Multisensory effects on somatosensation: a trimodal visuo-vestibular-tactile interaction

    PubMed Central

    Kaliuzhna, Mariia; Ferrè, Elisa Raffaella; Herbelin, Bruno; Blanke, Olaf; Haggard, Patrick

    2016-01-01

    Vestibular information about self-motion is combined with other sensory signals. Previous research described both visuo-vestibular and vestibular-tactile bilateral interactions, but the simultaneous interaction between all three sensory modalities has not been explored. Here we exploit a previously reported visuo-vestibular integration to investigate multisensory effects on tactile sensitivity in humans. Tactile sensitivity was measured during passive whole body rotations alone or in conjunction with optic flow, creating either purely vestibular or visuo-vestibular sensations of self-motion. Our results demonstrate that tactile sensitivity is modulated by perceived self-motion, as provided by a combined visuo-vestibular percept, and not by the visual and vestibular cues independently. We propose a hierarchical multisensory interaction that underpins somatosensory modulation: visual and vestibular cues are first combined to produce a multisensory self-motion percept. Somatosensory processing is then enhanced according to the degree of perceived self-motion. PMID:27198907

  9. A Tactile Stimulator for Studying Passive Shape Perception

    PubMed Central

    Lane, John W.; Fitzgerald, Paul J.; Yau, Jeffrey M.; Pembeci, Izzet; Hsiao, Steven S.

    2009-01-01

    We describe a computer-controlled tactile stimulator for use in human psychophysical and monkey neurophysiological studies of 3-D shape perception. The stimulator is constructed primarily of commercially available parts, as well as a few custom-built pieces for which we will supply diagrams upon request. There are two components to the stimulator: a tactile component and a hand positioner component. The tactile component consists of multiple stimulating units that move about in a Cartesian plane above the restrained hand. Each stimulating unit contains a servo-controlled linear motor with an attached small rotary stepper motor, allowing arbitrary stimulus shapes to contact the skin through vibration, static indentation, or scanning. The hand positioner component modifies the conformation of the restrained hand through a set of mechanical linkages under motorized control. The present design controls the amount of spread between digits two and three, the spread between digits four and three, and the degree to which digit three is flexed or extended, thereby simulating different conformations of the hand in contact with objects. This design is easily modified to suit the needs of the experimenter. Because the two components of the stimulator are independently controlled, the stimulator allows for parametric study of the mechanoreceptive and proprioceptive contributions to 3-D tactile shape perception. PMID:19800916

  10. Tactile short-term memory in sensory-deprived individuals.

    PubMed

    Papagno, Costanza; Minniti, Giovanna; Mattavelli, Giulia C; Mantovan, Lara; Cecchetto, Carlo

    2017-02-01

    To verify whether loosing a sense or two has consequences on a spared sensory modality, namely touch, and whether these consequences depend on practice or are biologically determined, we investigated 13 deafblind participants, 16 deaf participants, 15 blind participants, and 13 matched normally sighted and hearing controls on a tactile short-term memory task, using checkerboard matrices of increasing length in which half of the squares were made up of a rough texture and half of a smooth one. Time of execution of a fixed matrix, number of correctly reproduced matrices, largest matrix correctly reproduced and tactile span were recorded. The three groups of sensory-deprived individuals did not differ in any measure, while blind and deaf participants outscored controls in all parameters except time of execution; the difference approached significance for deafblind people compared to controls only in one measure, namely correctly reproduced matrices. In blind and deafblind participants, performance negatively correlated with age of Braille acquisition, the older being the subject when acquiring Braille, the lower the performance, suggesting that practice plays a role. However, the fact that deaf participants, who did not share tactile experience, performed similarly to blind participants and significantly better than controls highlights that practice cannot be the only contribution to better tactile memory.

  11. Tactile Cueing as a Gravitational Substitute for Spatial Navigation During Parabolic Flight

    NASA Technical Reports Server (NTRS)

    Montgomery, K. L.; Beaton, K. H.; Barba, J. M.; Cackler, J. M.; Son, J. H.; Horsfield, S. P.; Wood, S. J.

    2010-01-01

    INTRODUCTION: Spatial navigation requires an accurate awareness of orientation in your environment. The purpose of this experiment was to examine how spatial awareness was impaired with changing gravitational cues during parabolic flight, and the extent to which vibrotactile feedback of orientation could be used to help improve performance. METHODS: Six subjects were restrained in a chair tilted relative to the plane floor, and placed at random positions during the start of the microgravity phase. Subjects reported their orientation using verbal reports, and used a hand-held controller to point to a desired target location presented using a virtual reality video mask. This task was repeated with and without constant tactile cueing of "down" direction using a belt of 8 tactors placed around the mid-torso. Control measures were obtained during ground testing using both upright and tilted conditions. RESULTS: Perceptual estimates of orientation and pointing accuracy were impaired during microgravity or during rotation about an upright axis in 1g. The amount of error was proportional to the amount of chair displacement. Perceptual errors were reduced during movement about a tilted axis on earth. CONCLUSIONS: Reduced perceptual errors during tilts in 1g indicate the importance of otolith and somatosensory cues for maintaining spatial awareness. Tactile cueing may improve navigation in operational environments or clinical populations, providing a non-visual non-auditory feedback of orientation or desired direction heading.

  12. Structural design and output characteristic analysis of magnetostrictive tactile sensor for robotic applications

    NASA Astrophysics Data System (ADS)

    Zheng, Wendong; Wang, Bowen; Liu, Huaping; Li, Yunkai; Zhao, Ran; Weng, Ling; Zhang, Changgeng

    2018-05-01

    A novel magnetostrictive tactile sensor has been designed according to the transduction mechanism of cilia and Villari effect of iron-gallium alloy. The tactile sensor consists of a Galfenol beam, a pair of permanent magnets, a Hall sensor and a signal processing system. Compared with the conventional tactile sensor, our proposed tactile sensor can not only detect the contact-force, but also sense stiffness of an object. The performance and measurement range of tactile sensor have theoretically been analyzed and experimentally investigated. The results have revealed that the sensibility of tactile sensor for sensing force is up to 22.81mV/N at applied bias magnetic field of 2.56kA/m. Moreover, the sensor can effectively discriminate objects with different stiffness. The sensor is characterized by high sensitivity, good linearity, and quick response. It has the potential of being miniaturized and integrated into the finger of a robotic hand to realize force sensing and object recognition in real-time.

  13. Tactile massage as a nursing intervention in child and adolescent psychiatry: nurses' experiences.

    PubMed

    Robertz, A-C; Rudolfsson, G

    2016-10-01

    WHAT IS KNOWN ABOUT THE SUBJECT?: There is little research on the implementation of tactile massage in child and adolescent psychiatry that describes children's and adolescents' experiences and outcomes. There is also limited knowledge of providing tactile massage in child and adolescent psychiatry. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: This paper describes 10 nurses' experiences of tactile massage as a nursing intervention in child and adolescent psychiatry. The nurses considered tactile massage a non-verbal nursing intervention that could complement other available treatments. It reveals their reflections on the impact of tactile massage on their nursing and on themselves as a person, including the belief that they had developed deepened self-reflection and attentiveness. The nurses highlighted the importance of providing a trusting environment and collaborating with the children and adolescents. They both experienced and observed that tactile massage triggered various physical and mental processes in the children and adolescents, such as improvement in sleep disturbances, an ability to relax in body and mind and a deeper connectedness with their own bodies and feelings. The nurses described instructing next of kin in the use of tactile massage, which they believed could serve as a tool at home, mainly as a way for next of kin to help their children to relax, fall asleep more easily and to deepen connectedness. However, the nurses stressed the need to consider if it was appropriate or desired by the children and adolescents. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: Tactile massage addresses the individual's emotional and physiological responses and could therefore bring holistic nursing to child and adolescent psychiatry. It could also help nurses in child and adolescent psychiatry to develop their attentiveness and sensitivity in acknowledging the needs of children and adolescents in psychiatric care. Introduction There is limited research on tactile

  14. Illusory Motion Reproduced by Deep Neural Networks Trained for Prediction.

    PubMed

    Watanabe, Eiji; Kitaoka, Akiyoshi; Sakamoto, Kiwako; Yasugi, Masaki; Tanaka, Kenta

    2018-01-01

    The cerebral cortex predicts visual motion to adapt human behavior to surrounding objects moving in real time. Although the underlying mechanisms are still unknown, predictive coding is one of the leading theories. Predictive coding assumes that the brain's internal models (which are acquired through learning) predict the visual world at all times and that errors between the prediction and the actual sensory input further refine the internal models. In the past year, deep neural networks based on predictive coding were reported for a video prediction machine called PredNet. If the theory substantially reproduces the visual information processing of the cerebral cortex, then PredNet can be expected to represent the human visual perception of motion. In this study, PredNet was trained with natural scene videos of the self-motion of the viewer, and the motion prediction ability of the obtained computer model was verified using unlearned videos. We found that the computer model accurately predicted the magnitude and direction of motion of a rotating propeller in unlearned videos. Surprisingly, it also represented the rotational motion for illusion images that were not moving physically, much like human visual perception. While the trained network accurately reproduced the direction of illusory rotation, it did not detect motion components in negative control pictures wherein people do not perceive illusory motion. This research supports the exciting idea that the mechanism assumed by the predictive coding theory is one of basis of motion illusion generation. Using sensory illusions as indicators of human perception, deep neural networks are expected to contribute significantly to the development of brain research.

  15. Visual detail about the body modulates tactile localisation biases.

    PubMed

    Margolis, Aaron N; Longo, Matthew R

    2015-02-01

    The localisation of tactile stimuli requires the integration of visual and somatosensory inputs within an internal representation of the body surface and is prone to consistent bias. Joints may play a role in segmenting such internal body representations, and may therefore influence tactile localisation biases, although the nature of this influence remains unclear. Here, we investigate the relationship between conceptual knowledge of joint locations and tactile localisation biases on the hand. In one task, participants localised tactile stimuli applied to the dorsum of their hand. A distal localisation bias was observed in all participants, consistent with previous results. We also manipulated the availability of visual information during this task, to determine whether the absence of this information could account for the distal bias observed here and by Mancini et al. (Neuropsychologia 49:1194-1201, 2011). The observed distal bias increased in magnitude when visual information was restricted, without a corresponding decrease in precision. In a separate task, the same participants indicated, from memory, knuckle locations on a silhouette image of their hand. Analogous distal biases were also seen in the knuckle localisation task. The accuracy of conceptual joint knowledge was not correlated with tactile localisation bias magnitude, although a similarity in observed bias direction suggests that both tasks may rely on a common, higher-order body representation. These results also suggest that distortions of conceptual body representation may be more common in healthy individuals than previously thought.

  16. Short-Term Visual Deprivation, Tactile Acuity, and Haptic Solid Shape Discrimination

    PubMed Central

    Crabtree, Charles E.; Norman, J. Farley

    2014-01-01

    Previous psychophysical studies have reported conflicting results concerning the effects of short-term visual deprivation upon tactile acuity. Some studies have found that 45 to 90 minutes of total light deprivation produce significant improvements in participants' tactile acuity as measured with a grating orientation discrimination task. In contrast, a single 2011 study found no such improvement while attempting to replicate these earlier findings. A primary goal of the current experiment was to resolve this discrepancy in the literature by evaluating the effects of a 90-minute period of total light deprivation upon tactile grating orientation discrimination. We also evaluated the potential effect of short-term deprivation upon haptic 3-D shape discrimination using a set of naturally-shaped solid objects. According to previous research, short-term deprivation enhances performance in a tactile 2-D shape discrimination task – perhaps a similar improvement also occurs for haptic 3-D shape discrimination. The results of the current investigation demonstrate that not only does short-term visual deprivation not enhance tactile acuity, it additionally has no effect upon haptic 3-D shape discrimination. While visual deprivation had no effect in our study, there was a significant effect of experience and learning for the grating orientation task – the participants' tactile acuity improved over time, independent of whether they had, or had not, experienced visual deprivation. PMID:25397327

  17. Short-term visual deprivation, tactile acuity, and haptic solid shape discrimination.

    PubMed

    Crabtree, Charles E; Norman, J Farley

    2014-01-01

    Previous psychophysical studies have reported conflicting results concerning the effects of short-term visual deprivation upon tactile acuity. Some studies have found that 45 to 90 minutes of total light deprivation produce significant improvements in participants' tactile acuity as measured with a grating orientation discrimination task. In contrast, a single 2011 study found no such improvement while attempting to replicate these earlier findings. A primary goal of the current experiment was to resolve this discrepancy in the literature by evaluating the effects of a 90-minute period of total light deprivation upon tactile grating orientation discrimination. We also evaluated the potential effect of short-term deprivation upon haptic 3-D shape discrimination using a set of naturally-shaped solid objects. According to previous research, short-term deprivation enhances performance in a tactile 2-D shape discrimination task - perhaps a similar improvement also occurs for haptic 3-D shape discrimination. The results of the current investigation demonstrate that not only does short-term visual deprivation not enhance tactile acuity, it additionally has no effect upon haptic 3-D shape discrimination. While visual deprivation had no effect in our study, there was a significant effect of experience and learning for the grating orientation task - the participants' tactile acuity improved over time, independent of whether they had, or had not, experienced visual deprivation.

  18. Human detection and discrimination of tactile repeatability, mechanical backlash, and temporal delay in a combined tactile-kinesthetic haptic display system.

    PubMed

    Doxon, Andrew J; Johnson, David E; Tan, Hong Z; Provancher, William R

    2013-01-01

    Many of the devices used in haptics research are over-engineered for the task and are designed with capabilities that go far beyond human perception levels. Designing devices that more closely match the limits of human perception will make them smaller, less expensive, and more useful. However, many device-centric perception thresholds have yet to be evaluated. To this end, three experiments were conducted, using one degree-of-freedom contact location feedback device in combination with a kinesthetic display, to provide a more explicit set of specifications for similar tactile-kinesthetic haptic devices. The first of these experiments evaluated the ability of humans to repeatedly localize tactile cues across the fingerpad. Subjects could localize cues to within 1.3 mm and showed bias toward the center of the fingerpad. The second experiment evaluated the minimum perceptible difference of backlash at the tactile element. Subjects were able to discriminate device backlash in excess of 0.46 mm on low-curvature models and 0.93 mm on high-curvature models. The last experiment evaluated the minimum perceptible difference of system delay between user action and device reaction. Subjects were able to discriminate delays in excess of 61 ms. The results from these studies can serve as the maximum (i.e., most demanding) device specifications for most tactile-kinesthetic haptic systems.

  19. Concurrent emotional pictures modulate temporal order judgments of spatially separated audio-tactile stimuli.

    PubMed

    Jia, Lina; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J

    2013-11-06

    Although attention can be captured toward high-arousal stimuli, little is known about how perceiving emotion in one modality influences the temporal processing of non-emotional stimuli in other modalities. We addressed this issue by presenting observers spatially uninformative emotional pictures while they performed an audio-tactile temporal-order judgment (TOJ) task. In Experiment 1, audio-tactile stimuli were presented at the same location straight ahead of the participants, who had to judge "which modality came first?". In Experiments 2 and 3, the audio-tactile stimuli were delivered one to the left and the other to the right side, and participants had to judge "which side came first?". We found both negative and positive high-arousal pictures to significantly bias TOJs towards the tactile and away from the auditory event when the audio-tactile stimuli were spatially separated; by contrast, there was no such bias when the audio-tactile stimuli originated from the same location. To further examine whether this bias is attributable to the emotional meanings conveyed by the pictures or to their high arousal effect, we compared and contrasted the influences of near-body threat vs. remote threat (emotional) pictures on audio-tactile TOJs in Experiment 3. The bias manifested only in the near-body threat condition. Taken together, the findings indicate that visual stimuli conveying meanings of near-body interaction activate a sensorimotor functional link prioritizing the processing of tactile over auditory signals when these signals are spatially separated. In contrast, audio-tactile signals from the same location engender strong crossmodal integration, thus counteracting modality-based attentional shifts induced by the emotional pictures. © 2013 Published by Elsevier B.V.

  20. Exploring the Invisible Universe: A Tactile and Braille Exhibit of Astronomical Images

    NASA Astrophysics Data System (ADS)

    Arcand, K. K.; Watzke, M.; de Pree, C.

    2010-06-01

    A tactile/Braille exhibit for the visually impaired community in the USA was launched in July 2009. The exhibit is part of the global From Earth to the Universe (FETTU) project, a Cornerstone of the International Year of Astronomy 2009. The science content of the travelling tactile/Braille exhibit includes explanations of our Sun, Eta Carinae, the Crab Nebula, the Whirlpool Galaxy and the electromagnetic spectrum, and was adapted from the tactile/Braille book Touch the Invisible Sky. We present some of the early observations and findings on the tactile/Braille FETTU exhibit. The new exhibit opens a wider door to experiencing and understanding astronomy for the underserved visually impaired population.

  1. Tactile display landing safety and precision improvements for the Space Shuttle

    NASA Astrophysics Data System (ADS)

    Olson, John M.

    A tactile display belt using 24 electro-mechanical tactile transducers (tactors) was used to determine if a modified tactile display system, known as the Tactile Situation Awareness System (TSAS) improved the safety and precision of a complex spacecraft (i.e. the Space Shuttle Orbiter) in guided precision approaches and landings. The goal was to determine if tactile cues enhance safety and mission performance through reduced workload, increased situational awareness (SA), and an improved operational capability by increasing secondary cognitive workload capacity and human-machine interface efficiency and effectiveness. Using both qualitative and quantitative measures such as NASA's Justiz Numerical Measure and Synwork1 scores, an Overall Workload (OW) measure, the Cooper-Harper rating scale, and the China Lake Situational Awareness scale, plus Pre- and Post-Flight Surveys, the data show that tactile displays decrease OW, improve SA, counteract fatigue, and provide superior warning and monitoring capacity for dynamic, off-nominal, high concurrent workload scenarios involving complex, cognitive, and multi-sensory critical scenarios. Use of TSAS for maintaining guided precision approaches and landings was generally intuitive, reduced training times, and improved task learning effects. Ultimately, the use of a homogeneous, experienced, and statistically robust population of test pilots demonstrated that the use of tactile displays for Space Shuttle approaches and landings with degraded vehicle systems, weather, and environmental conditions produced substantial improvements in safety, consistency, reliability, and ease of operations under demanding conditions. Recommendations for further analysis and study are provided in order to leverage the results from this research and further explore the potential to reduce the risk of spaceflight and aerospace operations in general.

  2. Establishing Auditory-Tactile-Visual Equivalence Classes in Children with Autism and Developmental Delays

    ERIC Educational Resources Information Center

    Mullen, Stuart; Dixon, Mark R.; Belisle, Jordan; Stanley, Caleb

    2017-01-01

    The current study sought to evaluate the efficacy of a stimulus equivalence training procedure in establishing auditory-tactile-visual stimulus classes with 2 children with autism and developmental delays. Participants were exposed to vocal-tactile (A-B) and tactile-picture (B-C) conditional discrimination training and were tested for the…

  3. The relationship between virtual body ownership and temperature sensitivity

    PubMed Central

    Llobera, Joan; Sanchez-Vives, M. V.; Slater, Mel

    2013-01-01

    In the rubber hand illusion, tactile stimulation seen on a rubber hand, that is synchronous with tactile stimulation felt on the hidden real hand, can lead to an illusion of ownership over the rubber hand. This illusion has been shown to produce a temperature decrease in the hidden hand, suggesting that such illusory ownership produces disownership of the real hand. Here, we apply immersive virtual reality (VR) to experimentally investigate this with respect to sensitivity to temperature change. Forty participants experienced immersion in a VR with a virtual body (VB) seen from a first-person perspective. For half the participants, the VB was consistent in posture and movement with their own body, and in the other half, there was inconsistency. Temperature sensitivity on the palm of the hand was measured before and during the virtual experience. The results show that temperature sensitivity decreased in the consistent compared with the inconsistent condition. Moreover, the change in sensitivity was significantly correlated with the subjective illusion of virtual arm ownership but modulated by the illusion of ownership over the full VB. This suggests that a full body ownership illusion results in a unification of the virtual and real bodies into one overall entity—with proprioception and tactile sensations on the real body integrated with the visual presence of the VB. The results are interpreted in the framework of a ‘body matrix’ recently introduced into the literature. PMID:23720537

  4. Tactile Perception in Adults with Autism: A Multidimensional Psychophysical Study

    ERIC Educational Resources Information Center

    Cascio, Carissa; McGlone, Francis; Folger, Stephen; Tannan, Vinay; Baranek, Grace; Pelphrey, Kevin A.; Essick, Gregory

    2008-01-01

    Although sensory problems, including unusual tactile sensitivity, are heavily associated with autism, there is a dearth of rigorous psychophysical research. We compared tactile sensation in adults with autism to controls on the palm and forearm, the latter innervated by low-threshold unmyelinated afferents subserving a social/affiliative…

  5. Neuromimetic Event-Based Detection for Closed-Loop Tactile Feedback Control of Upper Limb Prostheses

    PubMed Central

    Osborn, Luke; Kaliki, Rahul; Soares, Alcimar; Thakor, Nitish

    2016-01-01

    Upper limb amputees lack the valuable tactile sensing that helps provide context about the surrounding environment. Here we utilize tactile information to provide active touch feedback to a prosthetic hand. First, we developed fingertip tactile sensors for producing biomimetic spiking responses for monitoring contact, release, and slip of an object grasped by a prosthetic hand. We convert the sensor output into pulses, mimicking the rapid and slowly adapting spiking responses of receptor afferents found in the human body. Second, we designed and implemented two neuromimetic event-based algorithms, Compliant Grasping and Slip Prevention, on a prosthesis to create a local closed-loop tactile feedback control system (i.e. tactile information is sent to the prosthesis). Grasping experiments were designed to assess the benefit of this biologically inspired neuromimetic tactile feedback to a prosthesis. Results from able-bodied and amputee subjects show the average number of objects that broke or slipped during grasping decreased by over 50% and the average time to complete a grasping task decreased by at least 10% for most trials when comparing neuromimetic tactile feedback with no feedback on a prosthesis. Our neuromimetic method of closed-loop tactile sensing is a novel approach to improving the function of upper limb prostheses. PMID:27777640

  6. When Content Matters: The Role of Processing Code in Tactile Display Design.

    PubMed

    Ferris, Thomas K; Sarter, Nadine

    2010-01-01

    The distribution of tasks and stimuli across multiple modalities has been proposed as a means to support multitasking in data-rich environments. Recently, the tactile channel and, more specifically, communication via the use of tactile/haptic icons have received considerable interest. Past research has examined primarily the impact of concurrent task modality on the effectiveness of tactile information presentation. However, it is not well known to what extent the interpretation of iconic tactile patterns is affected by another attribute of information: the information processing codes of concurrent tasks. In two driving simulation studies (n = 25 for each), participants decoded icons composed of either spatial or nonspatial patterns of vibrations (engaging spatial and nonspatial processing code resources, respectively) while concurrently interpreting spatial or nonspatial visual task stimuli. As predicted by Multiple Resource Theory, performance was significantly worse (approximately 5-10 percent worse) when the tactile icons and visual tasks engaged the same processing code, with the overall worst performance in the spatial-spatial task pairing. The findings from these studies contribute to an improved understanding of information processing and can serve as input to multidimensional quantitative models of timesharing performance. From an applied perspective, the results suggest that competition for processing code resources warrants consideration, alongside other factors such as the naturalness of signal-message mapping, when designing iconic tactile displays. Nonspatially encoded tactile icons may be preferable in environments which already rely heavily on spatial processing, such as car cockpits.

  7. A flexible tactile sensitive sheet using a hetero-core fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Fujino, S.; Yamazaki, H.; Hosoki, A.; Watanabe, K.

    2014-05-01

    In this report, we have designed a tactile sensitive sheet based on a hetero-core fiber-optic sensor, which realize an areal sensing by using single sensor potion in one optical fiber line. Recently, flexible and wide-area tactile sensing technology is expected to applied to acquired biological information in living space and robot achieve long-term care services such as welfare and nursing-care and humanoid technology. A hetero-core fiber-optic sensor has several advantages such as thin and flexible transmission line, immunity to EMI. Additionally this sensor is sensitive to moderate bending actions with optical loss changes and is independent of temperature fluctuation. Thus, the hetero-core fiber-optic sensor can be suitable for areal tactile sensing. We measure pressure characteristic of the proposed sensitive sheet by changing the pressure position and pinching characteristic on the surface. The proposed tactile sensitive sheet shows monotonic responses on the whole sensitive sheet surface although different sensitivity by the position is observed at the sensitive sheet surface. Moreover, the tactile sensitive sheet could sufficiently detect the pinching motion. In addition, in order to realize the discrimination between pressure and pinch, we fabricated a doubled-over sensor using a set of tactile sensitive sheets, which has different kinds of silicon robbers as a sensitive sheet surface. In conclusion, the flexible material could be given to the tactile sensation which is attached under proposed sensitive sheet.

  8. Exploring potential social influences on brain potentials during anticipation of tactile stimulation.

    PubMed

    Shen, Guannan; Saby, Joni N; Drew, Ashley R; Marshall, Peter J

    2017-03-15

    This study explored interpersonal influences on electrophysiological responses during the anticipation of tactile stimulation. It is well-known that broad, negative-going potentials are present in the event-related potential (ERP) between a forewarning cue and a tactile stimulus. It has also been shown that the alpha-range mu rhythm shows a lateralized desynchronization over central electrode sites during anticipation of tactile stimulation of the hand. The current study used a tactile discrimination task in which a visual cue signaled that an upcoming stimulus would either be delivered 1500ms later to the participant's hand, to a task partner's hand, or to neither person. For the condition in which participants anticipated the tactile stimulation to their own hand, a negative potential (contingent negative variation, CNV) was observed in the ERP at central sites in the 1000ms prior to the tactile stimulus. Significant mu rhythm desynchronization was also present in the same time window. The magnitudes of the ERPs and of the mu desynchronization were greater in the contralateral than in the ipsilateral hemisphere prior to right hand stimulation. Similar ERP and EEG changes were not present when the visual cue indicated that stimulation would be delivered to the task partner or to neither person. The absence of social influences during anticipation of tactile stimulation, and the relationship between the two brain signatures of anticipatory attention (CNV and mu rhythm) are discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Investigation and modification of a commercially available tactile sensor suited for robotic applications. Thesis

    NASA Technical Reports Server (NTRS)

    Creus, Carolina

    1991-01-01

    Active (dynamic) tactile sensing was explored using a commercially available tactile array sensor. This task requires the redesign of the sensor interface and a full understanding of the old sensor hardware implementation. There were different stages to this research; the first stage involved the reverse engineering of the old tactile sensor. The second stage had to do with the exploration of the characteristics and behavior of the tactile sensor pad. The next stage dealt with the redesign of the sensor interface using the knowledge gained from the previous two stages. Finally, in the last stage, software to control the tactile sensor was developed to aid in the data acquisition process.

  10. Can Tactile Sensory Processing Differentiate Between Children with Autistic Disorder and Asperger's Disorder?

    PubMed Central

    2011-01-01

    Objective There are debates whether autistic disorder (autism) and Asperger's disorder are two distinct disorders. Moreover, interventional sensory occupational therapy should consider the clinical characteristics of patients. Already, commonalities and differences between Asperger's disorder and autistic disorder are not well studied. The aim of this study is to compare tactile sensory function of children with autistic disorder and children with Asperger's disorder. Methods Tactile sensory function was compared between 36 children with autism and 19 children with Asperger's disorder. The two disorders were diagnosed based on Diagnostic and Statistical Manual of Mental Disorders Fourth Edition, Text Revision. The parent-reported Tactile Dysfunction Checklist was used to assess the three aspects of hypersensitivity, hyposensitivity, and poor tactile perception and discrimination. Developmental coordination was also assessed. Results Developmental coordination problems total score was not associated with group. The mean (standard deviation) score of tactile hyper-responsivity was not different between the groups. Tactile hyporesponsivity and poor tactile perception and discrimination scores were statistically higher in autistic disorder than Asperger's disorder group. Conclusion These results for the first time indicated that at least some aspects of tactile perception can differentiate these two disorders. Children with autistic disorder have more tactile sensory seeking behaviors than children with Asperger's disorder. Moreover, the ability of children with autistic disorder for tactile discrimination and sensory perception is less than those with Asperger's disorder. Interventional sensory therapy in children with autistic disorder should have some characteristics that can be different and specific for children with Asperger's disorder. Formal intelligence quotient testing was not performed on all of the children evaluated, which is a limitation to this study. In

  11. Market study: Tactile paging system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A market survey was conducted regarding the commercialization potential and key market factors relevant to a tactile paging system for deaf-blind people. The purpose of the tactile paging system is to communicate to the deaf-blind people in an institutional environment. The system consists of a main console and individual satellite wrist units. The console emits three signals by telemetry to the wrist com (receiving unit) which will measure approximately 2 x 4 x 3/4 inches and will be fastened to the wrist by a strap. The three vibration signals are fire alarm, time period indication, and a third signal which will alert the wearer of the wrist com to the fact that the pin on the top of the wrist is emitting a morse coded message. The Morse code message can be felt and recognized with the finger.

  12. Brief Report: Atypical Neuromagnetic Responses to Illusory Auditory Pitch in Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Brock, Jon; Bzishvili, Samantha; Reid, Melanie; Hautus, Michael; Johnson, Blake W.

    2013-01-01

    Atypical auditory perception is a widely recognised but poorly understood feature of autism. In the current study, we used magnetoencephalography to measure the brain responses of 10 autistic children as they listened passively to dichotic pitch stimuli, in which an illusory tone is generated by sub-millisecond inter-aural timing differences in…

  13. Tactile Functioning in Children Who Are Blind: A Clinical Perspective

    ERIC Educational Resources Information Center

    Withagen, Ans; Vervloed, Mathijs P. J.; Janssen, Neeltje M.; Knoors, Harry; Verhoeven, Ludo

    2010-01-01

    This study of 48 children with congenital blindness who attended mainstream schools focused on the tactile and haptic skills they needed in typical academic and everyday tasks. The results showed that, in general, the children mastered such tactile tasks, but some items posed special problems. (Contains 4 tables.)

  14. A Prototype Tactile Sensor Array.

    DTIC Science & Technology

    1982-09-15

    Active Touch Sensing. Technical Report, MIT Artificial Inteligence Laboratory, 1981. (9] Larcombe, M. Carbon Fibre Tactile Sensors. Technical Report...thesis, Carnegie-Mellon University, 1981. [13] Purbrick, John A. A Force Transducer Employing Conductive Silicone Rubber. Technical Report, MIT Artificial

  15. Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring

    PubMed Central

    Tseng, Hong-Jie; Tian, Wei-Cheng; Wu, Wen-Jong

    2013-01-01

    This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g. PMID:23698262

  16. Flexible PZT thin film tactile sensor for biomedical monitoring.

    PubMed

    Tseng, Hong-Jie; Tian, Wei-Cheng; Wu, Wen-Jong

    2013-04-25

    This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

  17. Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment

    PubMed Central

    Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé

    2015-01-01

    Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments. PMID:27019593

  18. Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment.

    PubMed

    Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé

    2015-01-01

    Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments.

  19. Illusory memories of emotionally charged words in autism spectrum disorder: further evidence for atypical emotion processing outside the social domain.

    PubMed

    Gaigg, Sebastian B; Bowler, Dermot M

    2009-07-01

    Recent evidence suggests that individuals with ASD may not accumulate distinct representations of emotional information throughout development. On the basis of this observation we predicted that such individuals would not be any less likely to falsely remember emotionally significant as compared to neutral words when such illusory memories are induced by asking participants to study lists of words that are orthographically associated to these words. Our findings showed that typical participants are far less likely to experience illusory memories of emotionally charged as compared to neutral words. Individuals with ASD, on the other hand, did not exhibit this emotional modulation of false memories. We discuss this finding in relation to the role of emotional processing atypicalities in ASD.

  20. Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions.

    PubMed

    van Raalte, Heather; Egorov, Vladimir

    2015-08-01

    The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions ( p < 0.05 for one-way ANOVA and/or p < 0.05 for t -test with correlation factor r from -0.73 to -0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse.

  1. Illusory Motion Reproduced by Deep Neural Networks Trained for Prediction

    PubMed Central

    Watanabe, Eiji; Kitaoka, Akiyoshi; Sakamoto, Kiwako; Yasugi, Masaki; Tanaka, Kenta

    2018-01-01

    The cerebral cortex predicts visual motion to adapt human behavior to surrounding objects moving in real time. Although the underlying mechanisms are still unknown, predictive coding is one of the leading theories. Predictive coding assumes that the brain's internal models (which are acquired through learning) predict the visual world at all times and that errors between the prediction and the actual sensory input further refine the internal models. In the past year, deep neural networks based on predictive coding were reported for a video prediction machine called PredNet. If the theory substantially reproduces the visual information processing of the cerebral cortex, then PredNet can be expected to represent the human visual perception of motion. In this study, PredNet was trained with natural scene videos of the self-motion of the viewer, and the motion prediction ability of the obtained computer model was verified using unlearned videos. We found that the computer model accurately predicted the magnitude and direction of motion of a rotating propeller in unlearned videos. Surprisingly, it also represented the rotational motion for illusion images that were not moving physically, much like human visual perception. While the trained network accurately reproduced the direction of illusory rotation, it did not detect motion components in negative control pictures wherein people do not perceive illusory motion. This research supports the exciting idea that the mechanism assumed by the predictive coding theory is one of basis of motion illusion generation. Using sensory illusions as indicators of human perception, deep neural networks are expected to contribute significantly to the development of brain research. PMID:29599739

  2. Optical based tactile shear and normal load sensor

    DOEpatents

    Salisbury, Curt Michael

    2015-06-09

    Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.

  3. Effects of inter-stimulus interval and intensity on the perceived urgency of tactile patterns.

    PubMed

    White, Timothy L; Krausman, Andrea S

    2015-05-01

    This research examines the feasibility of coding urgency into tactile patterns. Four tactile patterns were presented at either, 12 or 23.5 dB above mean threshold, with an ISI of either 0 (no interval) or 500 msec. Measures included pattern identification and urgency rating on a scale of 1 (least urgent) to 10 (most urgent). Two studies were conducted, a laboratory study and a field study. In the laboratory study, participants received the tactile patterns while seated in front of a computer. For the field study, participants performed dismounted Soldier maneuvers while receiving the tactile patterns. Higher identification rates were found for the 23.5 dB intensity. Patterns presented at the 23.5 dB intensity and no ISI were rated most urgent. No differences in urgency ratings were found for 12 dB based on ISI. Findings support the notion of coding urgency into tactile patterns as a way of augmenting tactile communication. Published by Elsevier Ltd.

  4. Illusory Late Heavy Bombardments

    NASA Astrophysics Data System (ADS)

    Boehnke, Patrick; Harrison, T. Mark

    2016-09-01

    The Late Heavy Bombardment (LHB), a hypothesized impact spike at ˜3.9 Ga, is one of the major scientific concepts to emerge from Apollo-era lunar exploration. A significant portion of the evidence for the existence of the LHB comes from histograms of 40Ar/39Ar “plateau” ages (i.e., regions selected on the basis of apparent isochroneity). However, due to lunar magmatism and overprinting from subsequent impact events, virtually all Apollo-era samples show evidence for 40Ar/39Ar age spectrum disturbances, leaving open the possibility that partial 40Ar* resetting could bias interpretation of bombardment histories due to plateaus yielding misleadingly young ages. We examine this possibility through a physical model of 40Ar* diffusion in Apollo samples and test the uniqueness of the impact histories obtained by inverting plateau age histograms. Our results show that plateau histograms tend to yield age peaks, even in those cases where the input impact curve did not contain such a spike, in part due to the episodic nature of lunar crust or parent body formation. Restated, monotonically declining impact histories yield apparent age peaks that could be misinterpreted as LHB-type events. We further conclude that the assignment of apparent 40Ar/39Ar plateau ages bears an undesirably high degree of subjectivity. When compounded by inappropriate interpretations of histograms constructed from plateau ages, interpretation of apparent, but illusory, impact spikes is likely.

  5. Illusory Late Heavy Bombardments

    PubMed Central

    Boehnke, Patrick; Harrison, T. Mark

    2016-01-01

    The Late Heavy Bombardment (LHB), a hypothesized impact spike at ∼3.9 Ga, is one of the major scientific concepts to emerge from Apollo-era lunar exploration. A significant portion of the evidence for the existence of the LHB comes from histograms of 40Ar/39Ar “plateau” ages (i.e., regions selected on the basis of apparent isochroneity). However, due to lunar magmatism and overprinting from subsequent impact events, virtually all Apollo-era samples show evidence for 40Ar/39Ar age spectrum disturbances, leaving open the possibility that partial 40Ar* resetting could bias interpretation of bombardment histories due to plateaus yielding misleadingly young ages. We examine this possibility through a physical model of 40Ar* diffusion in Apollo samples and test the uniqueness of the impact histories obtained by inverting plateau age histograms. Our results show that plateau histograms tend to yield age peaks, even in those cases where the input impact curve did not contain such a spike, in part due to the episodic nature of lunar crust or parent body formation. Restated, monotonically declining impact histories yield apparent age peaks that could be misinterpreted as LHB-type events. We further conclude that the assignment of apparent 40Ar/39Ar plateau ages bears an undesirably high degree of subjectivity. When compounded by inappropriate interpretations of histograms constructed from plateau ages, interpretation of apparent, but illusory, impact spikes is likely. PMID:27621460

  6. Achieving a hybrid brain-computer interface with tactile selective attention and motor imagery.

    PubMed

    Ahn, Sangtae; Ahn, Minkyu; Cho, Hohyun; Chan Jun, Sung

    2014-12-01

    We propose a new hybrid brain-computer interface (BCI) system that integrates two different EEG tasks: tactile selective attention (TSA) using a vibro-tactile stimulator on the left/right finger and motor imagery (MI) of left/right hand movement. Event-related desynchronization (ERD) from the MI task and steady-state somatosensory evoked potential (SSSEP) from the TSA task are retrieved and combined into two hybrid senses. One hybrid approach is to measure two tasks simultaneously; the features of each task are combined for testing. Another hybrid approach is to measure two tasks consecutively (TSA first and MI next) using only MI features. For comparison with the hybrid approaches, the TSA and MI tasks are measured independently. Using a total of 16 subject datasets, we analyzed the BCI classification performance for MI, TSA and two hybrid approaches in a comparative manner; we found that the consecutive hybrid approach outperformed the others, yielding about a 10% improvement in classification accuracy relative to MI alone. It is understood that TSA may play a crucial role as a prestimulus in that it helps to generate earlier ERD prior to MI and thus sustains ERD longer and to a stronger degree; this ERD may give more discriminative information than ERD in MI alone. Overall, our proposed consecutive hybrid approach is very promising for the development of advanced BCI systems.

  7. Achieving a hybrid brain-computer interface with tactile selective attention and motor imagery

    NASA Astrophysics Data System (ADS)

    Ahn, Sangtae; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan

    2014-12-01

    Objective. We propose a new hybrid brain-computer interface (BCI) system that integrates two different EEG tasks: tactile selective attention (TSA) using a vibro-tactile stimulator on the left/right finger and motor imagery (MI) of left/right hand movement. Event-related desynchronization (ERD) from the MI task and steady-state somatosensory evoked potential (SSSEP) from the TSA task are retrieved and combined into two hybrid senses. Approach. One hybrid approach is to measure two tasks simultaneously; the features of each task are combined for testing. Another hybrid approach is to measure two tasks consecutively (TSA first and MI next) using only MI features. For comparison with the hybrid approaches, the TSA and MI tasks are measured independently. Main results. Using a total of 16 subject datasets, we analyzed the BCI classification performance for MI, TSA and two hybrid approaches in a comparative manner; we found that the consecutive hybrid approach outperformed the others, yielding about a 10% improvement in classification accuracy relative to MI alone. It is understood that TSA may play a crucial role as a prestimulus in that it helps to generate earlier ERD prior to MI and thus sustains ERD longer and to a stronger degree; this ERD may give more discriminative information than ERD in MI alone. Significance. Overall, our proposed consecutive hybrid approach is very promising for the development of advanced BCI systems.

  8. Nanowire FET Based Neural Element for Robotic Tactile Sensing Skin

    PubMed Central

    Taube Navaraj, William; García Núñez, Carlos; Shakthivel, Dhayalan; Vinciguerra, Vincenzo; Labeau, Fabrice; Gregory, Duncan H.; Dahiya, Ravinder

    2017-01-01

    This paper presents novel Neural Nanowire Field Effect Transistors (υ-NWFETs) based hardware-implementable neural network (HNN) approach for tactile data processing in electronic skin (e-skin). The viability of Si nanowires (NWs) as the active material for υ-NWFETs in HNN is explored through modeling and demonstrated by fabricating the first device. Using υ-NWFETs to realize HNNs is an interesting approach as by printing NWs on large area flexible substrates it will be possible to develop a bendable tactile skin with distributed neural elements (for local data processing, as in biological skin) in the backplane. The modeling and simulation of υ-NWFET based devices show that the overlapping areas between individual gates and the floating gate determines the initial synaptic weights of the neural network - thus validating the working of υ-NWFETs as the building block for HNN. The simulation has been further extended to υ-NWFET based circuits and neuronal computation system and this has been validated by interfacing it with a transparent tactile skin prototype (comprising of 6 × 6 ITO based capacitive tactile sensors array) integrated on the palm of a 3D printed robotic hand. In this regard, a tactile data coding system is presented to detect touch gesture and the direction of touch. Following these simulation studies, a four-gated υ-NWFET is fabricated with Pt/Ti metal stack for gates, source and drain, Ni floating gate, and Al2O3 high-k dielectric layer. The current-voltage characteristics of fabricated υ-NWFET devices confirm the dependence of turn-off voltages on the (synaptic) weight of each gate. The presented υ-NWFET approach is promising for a neuro-robotic tactile sensory system with distributed computing as well as numerous futuristic applications such as prosthetics, and electroceuticals. PMID:28979183

  9. Salience of Tactile Cues: An Examination of Tactor Actuator and Tactile Cue Characteristics

    DTIC Science & Technology

    2015-08-01

    this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense ...patterns of tactile cue arrays, and some differences due to measurement approach. Implications for future research are discussed. 15. SUBJECT TERMS...results for tactor type, taction, and interaction term for the prediction of forced-choice preference ................................................21

  10. The role of alpha oscillations for illusory perception

    PubMed Central

    Lange, Joachim; Keil, Julian; Schnitzler, Alfons; van Dijk, Hanneke; Weisz, Nathan

    2014-01-01

    Alpha oscillations are a prominent electrophysiological signal measured across a wide range of species and cortical and subcortical sites. Alpha oscillations have been viewed for a long time as an “idling” rhythm, purely reflecting inactive sites. Despite earlier evidence from neurophysiology, awareness that alpha oscillations can substantially influence perception and behavior has grown only recently in cognitive neuroscience. Evidence for an active role of alpha for perception comes mainly from several visual, near-threshold experiments. In the current review, we extend this view by summarizing studies showing how alpha-defined brain states relate to illusory perception, i.e. cases of perceptual reports that are not “objectively” verifiable by distinct stimuli or stimulus features. These studies demonstrate that ongoing or prestimulus alpha oscillations substantially influence the perception of auditory, visual or multisensory illusions. PMID:24931795

  11. An Experimental Optical Three-axis Tactile Sensor Featured with Hemispherical Surface

    NASA Astrophysics Data System (ADS)

    Ohka, Masahiro; Kobayashi, Hiroaki; Takata, Jumpei; Mitsuya, Yasunaga

    We are developing an optical three-axis tactile sensor capable of acquiring normal and shearing force to mount on a robotic finger. The tactile sensor is based on the principle of an optical waveguide-type tactile sensor, which is composed of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera. The sensing element of the silicone rubber comprises one columnar feeler and eight conical feelers. The contact areas of the conical feelers, which maintain contact with the acrylic dome, detect the three-axis force applied to the tip of the sensing element. Normal and shearing forces are then calculated from integration and centroid displacement of the grayscale value derived from the conical feeler's contacts. To evaluate the present tactile sensor, we conducted a series of experiments using an x-z stage, a rotational stage, and a force gauge. Although we discovered that the relationship between the integrated grayscale value and normal force depends on the sensor's latitude on the hemispherical surface, it is easy to modify the sensitivity based on the latitude to make the centroid displacement of the grayscale value proportional to the shearing force. When we examined the repeatability of the present tactile sensor with 1,000 load/unload cycles, the error was 2%.

  12. Bilateral Symmetry of Distortions of Tactile Size Perception.

    PubMed

    Longo, Matthew R; Ghosh, Arko; Yahya, Tasneem

    2015-01-01

    The perceived distance between touches on the limbs is generally bigger for distances oriented across the width of the limb than for distances oriented along the length of the limb. The present study aimed to investigate the coherence of such distortions of tactile size perception across different skin surfaces. We investigated distortions of tactile size perception on the dorsal and palmar surfaces of both the left and right hands as well as the forehead. Participants judged which of two tactile distances felt larger. One distance was aligned with the proximodistal axis (along the body), the other with the mediolateral axis (across the body). Clear distortions were found on all five skin surfaces, with stimuli oriented across the width of the body being perceived as farther apart than those oriented along the length of the body. Consistent with previous results, distortions were smaller on the palmar than on the dorsal hand surface. Distortion on the forehead was intermediate between the dorsal and palmar surfaces. There were clear correlations between distortion on the left and right hands, for both the dorsal and palmar skin surfaces. In contrast, within each hand, there was no significant correlation between the two skin surfaces. Distortion on the forehead was not significantly correlated with that on any of the other skin surfaces. These results provide evidence for bilaterally symmetric representations underlying tactile size perception. © The Author(s) 2015.

  13. Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions

    PubMed Central

    van Raalte, Heather; Egorov, Vladimir

    2015-01-01

    The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions (p < 0.05 for one-way ANOVA and/or p < 0.05 for t-test with correlation factor r from −0.73 to −0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse. PMID:26389014

  14. Braille and Tactile Graphics: Youths with Visual Impairments Share Their Experiences

    ERIC Educational Resources Information Center

    Rosenblum, L. Penny; Herzberg, Tina S.

    2015-01-01

    Introduction: Data were collected from youths with visual impairment about their experiences with tactile graphics and braille materials used in mathematics and science classes. Methods: Youths answered questions and explored four tactile graphics made using different production methods. They located specific information on each graphic and shared…

  15. Use of early tactile stimulation in rehabilitation of digital nerve injuries.

    PubMed

    Cheng, A S

    2000-01-01

    Digital nerves are the most frequently injured peripheral nerve. To improve the recovery of functional sensibility of digital nerve injuries, a prospective randomized controlled study was conducted to see the effect of using early tactile stimulation in rehabilitation of digital nerve injuries. Two specific tactile stimulators were made and prescribed for patients with digital nerve-injury. Twenty-four participants with 32 digital nerve injuries received the prescribed tactile stimulators (experimental group), and another 25 participants with 33 digital nerve injuries received only routine conventional therapy (control group). A significant difference (p < .05) was seen in the experimental group, although there were some variations between the different classes of associated injuries, with least benefit observed in the combined nerve, tendon, and bone injury class. Use of early tactile stimulation as described in this study can be considered an effective way to improve both quality and quantity of recovery of functional sensibility in digital nerve injuries without combined nerve, tendon, and bone injuries.

  16. Tactile agnosia. Casuistic evidence and theoretical remarks on modality-specific meaning representations and sensorimotor integration.

    PubMed

    Platz, T

    1996-10-01

    Somaesthetic, motor and cognitive functions were studied in a man with impaired tactile object-recognition (TOR) in his left hand due to a right parietal convexity meningeoma which had been surgically removed. Primary motor and somatosensory functions were not impaired, and discriminative abilities for various tactile aspects and cognitive skills were preserved. Nevertheless, the patient could often not appreciate the object's nature or significance when it was placed in his left hand and was unable to name or to describe or demonstrate the use of these objects. Therefore, he can be regarded as an example of associative tactile agnosia. The view is taken and elaborated that defective modality-specific meaning representations account for associative tactile agnosia. These meaning representations are conceptualized as learned unimodal feature-entity relationships which are thought to be defective in tactile agnosia. In line with this hypothesis, tactile feature analysis and cross-modal matching of features were largely preserved in the investigated patient, while combining features to form entities was defective in the tactile domain. The alternative hypothesis of agnosia as deficit of cross-modal association of features was not supported. The presumed distributed functional network responsible for TOR is thought to involve perception of features, object recognition and related tactile motor behaviour interactively. A deficit leading primarily to impaired combining features to form entities can therefore be expected to result in additional minor impairment of related perceptual-motor processes. Unilaterality of the gnostic deficit can be explained by a lateralized organization of the functional network responsible for tactile recognition of objects.

  17. Tactile Perception of Roughness and Hardness to Discriminate Materials by Friction-Induced Vibration

    PubMed Central

    Zhao, Xuezeng

    2017-01-01

    The human fingertip is an exquisitely powerful bio-tactile sensor in perceiving different materials based on various highly-sensitive mechanoreceptors distributed all over the skin. The tactile perception of surface roughness and material hardness can be estimated by skin vibrations generated during a fingertip stroking of a surface instead of being maintained in a static position. Moreover, reciprocating sliding with increasing velocities and pressures are two common behaviors in humans to discriminate different materials, but the question remains as to what the correlation of the sliding velocity and normal load on the tactile perceptions of surface roughness and hardness is for material discrimination. In order to investigate this correlation, a finger-inspired crossed-I beam structure tactile tester has been designed to mimic the anthropic tactile discrimination behaviors. A novel method of characterizing the fast Fourier transform integral (FFT) slope of the vibration acceleration signal generated from fingertip rubbing on surfaces at increasing sliding velocity and normal load, respectively, are defined as kv and kw, and is proposed to discriminate the surface roughness and hardness of different materials. Over eight types of materials were tested, and they proved the capability and advantages of this high tactile-discriminating method. Our study may find applications in investigating humanoid robot perceptual abilities. PMID:29182538

  18. Integration of tactile input across fingers in a patient with finger agnosia.

    PubMed

    Anema, Helen A; Overvliet, Krista E; Smeets, Jeroen B J; Brenner, Eli; Dijkerman, H Chris

    2011-01-01

    Finger agnosia has been described as an inability to explicitly individuate between the fingers, which is possibly due to fused neural representations of these fingers. Hence, are patients with finger agnosia unable to keep tactile information perceived over several fingers separate? Here, we tested a finger agnosic patient (GO) on two tasks that measured the ability to keep tactile information simultaneously perceived by individual fingers separate. In experiment 1 GO performed a haptic search task, in which a target (the absence of a protruded line) needed to be identified among distracters (protruded lines). The lines were presented simultaneously to the fingertips of both hands. Similarly to the controls, her reaction time decreased when her fingers were aligned as compared to when her fingers were stretched and in an unaligned position. This suggests that she can keep tactile input from different fingers separate. In experiment two, GO was required to judge the position of a target tactile stimulus to the index finger, relatively to a reference tactile stimulus to the middle finger, both in fingers uncrossed and crossed position. GO was able to indicate the relative position of the target stimulus as well as healthy controls, which indicates that she was able to keep tactile information perceived by two neighbouring fingers separate. Interestingly, GO performed better as compared to the healthy controls in the finger crossed condition. Together, these results suggest the GO is able to implicitly distinguish between tactile information perceived by multiple fingers. We therefore conclude that finger agnosia is not caused by minor disruptions of low-level somatosensory processing. These findings further underpin the idea of a selective impaired higher order body representation restricted to the fingers as underlying cause of finger agnosia. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. The role of tactile feedback in grip force during laparoscopic training tasks.

    PubMed

    Wottawa, Christopher R; Cohen, Jeremiah R; Fan, Richard E; Bisley, James W; Culjat, Martin O; Grundfest, Warren S; Dutson, Erik P

    2013-04-01

    Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon's hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.

  20. Microstructured graphene arrays for highly sensitive flexible tactile sensors.

    PubMed

    Zhu, Bowen; Niu, Zhiqiang; Wang, Hong; Leow, Wan Ru; Wang, Hua; Li, Yuangang; Zheng, Liyan; Wei, Jun; Huo, Fengwei; Chen, Xiaodong

    2014-09-24

    A highly sensitive tactile sensor is devised by applying microstructured graphene arrays as sensitive layers. The combination of graphene and anisotropic microstructures endows this sensor with an ultra-high sensitivity of -5.53 kPa(-1) , an ultra-fast response time of only 0.2 ms, as well as good reliability, rendering it promising for the application of tactile sensing in artificial skin and human-machine interface. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Improved tactile resonance sensor for robotic assisted surgery

    NASA Astrophysics Data System (ADS)

    Oliva Uribe, David; Schoukens, Johan; Stroop, Ralf

    2018-01-01

    This paper presents an improved tactile sensor using a piezoelectric bimorph able to differentiate soft materials with similar mechanical characteristics. The final aim is to develop intelligent surgical tools for brain tumour resection using integrated sensors in order to improve tissue tumour delineation and tissue differentiation. The bimorph sensor is driven using a random phase multisine and the properties of contact between the sensor's tip and a certain load are evaluated by means of the evaluation of the nonparametric FRF. An analysis of the nonlinear contributions is presented to show that the use of a linear model is feasible for the measurement conditions. A series of gelatine phantoms were tested. The tactile sensor is able to identify minimal differences in the consistency of the measured samples considering viscoelastic behaviour. A variance analysis was performed to evaluate the reliability of the sensors and to identify possible error sources due to inconsistencies in the preparation method of the phantoms. The results of the variance analysis are discussed showing that ability of the proposed tactile sensor to perform high quality measurements.

  2. Tactile sensitivity of gloved hands in the cold operation.

    PubMed

    Geng, Q; Kuklane, K; Holmér, I

    1997-11-01

    In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.

  3. Type of featural attention differentially modulates hMT+ responses to illusory motion aftereffects.

    PubMed

    Castelo-Branco, Miguel; Kozak, Lajos R; Formisano, Elia; Teixeira, João; Xavier, João; Goebel, Rainer

    2009-11-01

    Activity in the human motion complex (hMT(+)/V5) is related to the perception of motion, be it either real surface motion or an illusion of motion such as apparent motion (AM) or motion aftereffect (MAE). It is a long-lasting debate whether illusory motion-related activations in hMT(+) represent the motion itself or attention to it. We have asked whether hMT(+) responses to MAEs are present when shifts in arousal are suppressed and attention is focused on concurrent motion versus nonmotion features. Significant enhancement of hMT(+) activity was observed during MAEs when attention was focused either on concurrent spatial angle or color features. This observation was confirmed by direct comparison of adapting (MAE inducing) versus nonadapting conditions. In contrast, this effect was diminished when subjects had to report on concomitant speed changes of superimposed AM. The same finding was observed for concomitant orthogonal real motion (RM), suggesting that selective attention to concurrent illusory or real motion was interfering with the saliency of MAE signals in hMT(+). We conclude that MAE-related changes in the global activity of hMT(+) are present provided selective attention is not focused on an interfering feature such as concurrent motion. Accordingly, there is a genuine MAE-related motion signal in hMT(+) that is neither explained by shifts in arousal nor by selective attention.

  4. Tactile perceptual learning: learning curves and transfer to the contralateral finger.

    PubMed

    Kaas, Amanda L; van de Ven, Vincent; Reithler, Joel; Goebel, Rainer

    2013-02-01

    Tactile perceptual learning has been shown to improve performance on tactile tasks, but there is no agreement about the extent of transfer to untrained skin locations. The lack of such transfer is often seen as a behavioral index of the contribution of early somatosensory brain regions. Moreover, the time course of improvements has never been described explicitly. Sixteen subjects were trained on the Ludvigh task (a tactile vernier task) on four subsequent days. On the fifth day, transfer of learning to the non-trained contralateral hand was tested. In five subjects, we explored to what extent training effects were retained approximately 1.5 years after the final training session, expecting to find long-term retention of learning effects after training. Results showed that tactile perceptual learning mainly occurred offline, between sessions. Training effects did not transfer initially, but became fully available to the untrained contralateral hand after a few additional training runs. After 1.5 years, training effects were not fully washed out and could be recuperated within a single training session. Interpreted in the light of theories of visual perceptual learning, these results suggest that tactile perceptual learning is not fundamentally different from visual perceptual learning, but might proceed at a slower pace due to procedural and task differences, thus explaining the apparent divergence in the amount of transfer and long-term retention.

  5. Pure Amorphagnosia without Tactile Object Agnosia.

    PubMed

    Kubota, Shinichirou; Yamada, Mai; Satoh, Hideyo; Satoh, Akira; Tsujihata, Mitsuhiro

    2017-01-01

    A 54-year-old female showed amorphagnosia without ahylognosia and tactile agnosia 40 days after the onset of right cerebral infarction. Her basic somatosensory functions were normal. The appreciation of substance qualities (hylognosia) was preserved, but the patient's inability to recognize the size and shape (morphagnosia) was confined to 2- and 3-dimensional shapes (amorphagnosia) in the left hand. However, the patient's ability to recognize real daily objects was well preserved. Brain MRI after admission showed ischemic lesions confined to the right pre- and postcentral gyri and the medial frontal cortex on DWI and FLAIR images. An analysis of SPECT images revealed that the most decreased areas were localized to the pre- and postcentral gyri, superior and inferior parietal lobules, supramarginal gyrus, and angular gyrus. Considering the previous reported cases, the responsible lesion for the impaired perception of hylognosia and morphagnosia may not necessarily be confined to the right hemisphere. To date, 5 reports (6 cases) of tactile agnosia have been published; 4 cases presented with both ahylognosia and amorphagnosia, while 1 presented with only amorphagnosia, and another showed amorphagnosia and mild ahylognosia. Our case is the first to present with only amorphagnosia without tactile agnosia. The mechanism for the well-preserved recognition of real objects may depend on the preserved hylognosia. Of note, there have been no reports showing only ahylognosia without amorphagnosia. Further studies are necessary to clarify whether or not patients with preserved hylognosia or morphagnosia retain the ability to perceive real objects.

  6. Generalization of a tactile stimulus in horses.

    PubMed Central

    Dougherty, D M; Lewis, P

    1993-01-01

    Using horses, we investigated the control of operant behavior by a tactile stimulus (the training stimulus) and the generalization of behavior to six other similar test stimuli. In a stall, the experimenters mounted a response panel in the doorway. Located on this panel were a response lever and a grain dispenser. The experimenters secured a tactile-stimulus belt to the horse's back. The stimulus belt was constructed by mounting seven solenoids along a piece of burlap in a manner that allowed each to provide the delivery of a tactile stimulus, a repetitive light tapping, at different locations (spaced 10.0 cm apart) along the horse's back. Two preliminary steps were necessary before generalization testing: training a measurable response (lip pressing) and training on several reinforcement schedules in the presence of a training stimulus (tapping by one of the solenoids). We then gave each horse two generalization test sessions. Results indicated that the horses' behavior was effectively controlled by the training stimulus. Horses made the greatest number of responses to the training stimulus, and the tendency to respond to the other test stimuli diminished as the stimuli became farther away from the training stimulus. These findings are discussed in the context of behavioral principles and their relevance to the training of horses. PMID:8315368

  7. Generalization of a tactile stimulus in horses.

    PubMed

    Dougherty, D M; Lewis, P

    1993-05-01

    Using horses, we investigated the control of operant behavior by a tactile stimulus (the training stimulus) and the generalization of behavior to six other similar test stimuli. In a stall, the experimenters mounted a response panel in the doorway. Located on this panel were a response lever and a grain dispenser. The experimenters secured a tactile-stimulus belt to the horse's back. The stimulus belt was constructed by mounting seven solenoids along a piece of burlap in a manner that allowed each to provide the delivery of a tactile stimulus, a repetitive light tapping, at different locations (spaced 10.0 cm apart) along the horse's back. Two preliminary steps were necessary before generalization testing: training a measurable response (lip pressing) and training on several reinforcement schedules in the presence of a training stimulus (tapping by one of the solenoids). We then gave each horse two generalization test sessions. Results indicated that the horses' behavior was effectively controlled by the training stimulus. Horses made the greatest number of responses to the training stimulus, and the tendency to respond to the other test stimuli diminished as the stimuli became farther away from the training stimulus. These findings are discussed in the context of behavioral principles and their relevance to the training of horses.

  8. Left hand tactile agnosia after posterior callosal lesion.

    PubMed

    Balsamo, Maddalena; Trojano, Luigi; Giamundo, Arcangelo; Grossi, Dario

    2008-09-01

    We report a patient with a hemorrhagic lesion encroaching upon the posterior third of the corpus callosum but sparing the splenium. She showed marked difficulties in recognizing objects and shapes perceived through her left hand, while she could appreciate elementary sensorial features of items tactually presented to the same hand flawlessly. This picture, corresponding to classical descriptions of unilateral associative tactile agnosia, was associated with finger agnosia of the left hand. This very unusual case report can be interpreted as an instance of disconnection syndrome, and allows a discussion of mechanisms involved in tactile object recognition.

  9. Refreshable tactile displays based on bistable electroactive polymer

    NASA Astrophysics Data System (ADS)

    Niu, Xiaofan; Brochu, Paul; Salazar, Brandon; Pei, Qibing

    2011-04-01

    Refreshable tactile displays can significantly improve the education of blind children and the quality of life of people with severe vision impairment. A number of actuator technologies have been investigated. Bistable Electroactive Polymer (BSEP) appears to be well suited for this application. The BSEP exhibits a bistable electrically actuated strain as large as 335%. We present improved refreshable tactile display devices fabricated on thin plastic sheets. Stacked BSEP films were employed to meet the requirements in raised dot height and supporting force. The bistable nature of the actuation reduces the power consumption and simplifies the device operation.

  10. Effect of tactile vibration on annoyance to synthesized propfan noise

    NASA Technical Reports Server (NTRS)

    Clevenson, S. A.

    1981-01-01

    Design information that maximizes passenger comfort for propfan aircraft is presented. Predicted noise and vibration environments and the resultant passenger acceptability were studied. The effect of high frequency tactile vibration (i.e., greater than 30 Hz) on passenger reactions was analyzed. Passenger reactions to a wide range of noise with and without tactile vibration was studied. The passenger ride quality simulator was employed using subjects who evaluated either synthesized propeller noises only, or these noises combined with seat/arm vibration. The noises ranging from 80-100 dB consisted of a turbulent boundary layer noise with a factorial combination of five blade passage frequencies (50-200 Hz), two harmonic rolloffs, and three tone/noise ratios. It is indicated that passenger reaction (annoyance) to noise is not significantly changed in the presence of tactile vibration.

  11. New Magnetic Microactuator Design Based on PDMS Elastomer and MEMS Technologies for Tactile Display.

    PubMed

    Streque, Jeremy; Talbi, Abdelkrim; Pernod, Philippe; Preobrazhensky, Vladimir

    2010-01-01

    Highly efficient tactile display devices must fulfill technical requirements for tactile stimulation, all the while preserving the lightness and compactness needed for handheld operation. This paper focuses on the elaboration of highly integrated magnetic microactuators for tactile display devices. FEM simulation, conception, fabrication, and characterization of these microactuators are presented in this paper. The current demonstrator offers a 4 × 4 flexible microactuator array with a resolution of 2 mm. Each actuator is composed of a Poly (Dimethyl-Siloxane) (PDMS) elastomeric membrane, magnetically actuated by coil-magnet interaction. It represents a proof of concept for fully integrated MEMS tactile devices, with fair actuation forces provided for a power consumption up to 100 mW per microactuator. The prototypes are destined to provide both static and dynamic tactile sensations, with an optimized membrane geometry for actuation frequencies between DC and 350 Hz. On the basis of preliminary experiments, this display device can offer skin stimulations for various tactile stimuli for applications in the fields of Virtual Reality or Human-Computer Interaction (HCI). Moreover, the elastomeric material used in this device and its global compactness offer great advantages in matter of comfort of use and capabilities of integration in haptic devices.

  12. Tactile-Sensing Based on Flexible PVDF Nanofibers via Electrospinning: A Review

    PubMed Central

    Wang, Xiaomei; Sun, Fazhe; Yin, Guangchao; Wang, Yuting; Liu, Bo

    2018-01-01

    The flexible tactile sensor has attracted widespread attention because of its great flexibility, high sensitivity, and large workable range. It can be integrated into clothing, electronic skin, or mounted on to human skin. Various nanostructured materials and nanocomposites with high flexibility and electrical performance have been widely utilized as functional materials in flexible tactile sensors. Polymer nanomaterials, representing the most promising materials, especially polyvinylidene fluoride (PVDF), PVDF co-polymer and their nanocomposites with ultra-sensitivity, high deformability, outstanding chemical resistance, high thermal stability and low permittivity, can meet the flexibility requirements for dynamic tactile sensing in wearable electronics. Electrospinning has been recognized as an excellent straightforward and versatile technique for preparing nanofiber materials. This review will present a brief overview of the recent advances in PVDF nanofibers by electrospinning for flexible tactile sensor applications. PVDF, PVDF co-polymers and their nanocomposites have been successfully formed as ultrafine nanofibers, even as randomly oriented PVDF nanofibers by electrospinning. These nanofibers used as the functional layers in flexible tactile sensors have been reviewed briefly in this paper. The β-phase content, which is the strongest polar moment contributing to piezoelectric properties among all the crystalline phases of PVDF, can be improved by adjusting the technical parameters in electrospun PVDF process. The piezoelectric properties and the sensibility for the pressure sensor are improved greatly when the PVDF fibers become more oriented. The tactile performance of PVDF composite nanofibers can be further promoted by doping with nanofillers and nanoclay. Electrospun P(VDF-TrFE) nanofiber mats used for the 3D pressure sensor achieved excellent sensitivity, even at 0.1 Pa. The most significant enhancement is that the aligned electrospun core-shell P

  13. A new dynamic tactile display for reconfigurable braille: implementation and tests.

    PubMed

    Motto Ros, Paolo; Dante, Vittorio; Mesin, Luca; Petetti, Erminio; Del Giudice, Paolo; Pasero, Eros

    2014-01-01

    Different tactile interfaces have been proposed to represent either text (braille) or, in a few cases, tactile large-area screens as replacements for visual displays. None of the implementations so far can be customized to match users' preferences, perceptual differences and skills. Optimal choices in these respects are still debated; we approach a solution by designing a flexible device allowing the user to choose key parameters of tactile transduction. We present here a new dynamic tactile display, a 8 × 8 matrix of plastic pins based on well-established and reliable piezoelectric technology to offer high resolution (pin gap 0.7mm) as well as tunable strength of the pins displacement, and refresh rate up to 50s(-1). It can reproduce arbitrary patterns, allowing it to serve the dual purpose of providing, depending on contingent user needs, tactile rendering of non-character information, and reconfigurable braille rendering. Given the relevance of the latter functionality for the expected average user, we considered testing braille encoding by volunteers a benchmark of primary importance. Tests were performed to assess the acceptance and usability with minimal training, and to check whether the offered flexibility was indeed perceived by the subject as an added value compared to conventional braille devices. Different mappings between braille dots and actual tactile pins were implemented to match user needs. Performances of eight experienced braille readers were defined as the fraction of correct identifications of rendered content. Different information contents were tested (median performance on random strings, words, sentences identification was about 75%, 85%, 98%, respectively, with a significant increase, p < 0.01), obtaining statistically significant improvements in performance during the tests (p < 0.05). Experimental results, together with qualitative ratings provided by the subjects, show a good acceptance and the effectiveness of the proposed solution.

  14. A new dynamic tactile display for reconfigurable braille: implementation and tests

    PubMed Central

    Motto Ros, Paolo; Dante, Vittorio; Mesin, Luca; Petetti, Erminio; Del Giudice, Paolo; Pasero, Eros

    2014-01-01

    Different tactile interfaces have been proposed to represent either text (braille) or, in a few cases, tactile large-area screens as replacements for visual displays. None of the implementations so far can be customized to match users' preferences, perceptual differences and skills. Optimal choices in these respects are still debated; we approach a solution by designing a flexible device allowing the user to choose key parameters of tactile transduction. We present here a new dynamic tactile display, a 8 × 8 matrix of plastic pins based on well-established and reliable piezoelectric technology to offer high resolution (pin gap 0.7mm) as well as tunable strength of the pins displacement, and refresh rate up to 50s−1. It can reproduce arbitrary patterns, allowing it to serve the dual purpose of providing, depending on contingent user needs, tactile rendering of non-character information, and reconfigurable braille rendering. Given the relevance of the latter functionality for the expected average user, we considered testing braille encoding by volunteers a benchmark of primary importance. Tests were performed to assess the acceptance and usability with minimal training, and to check whether the offered flexibility was indeed perceived by the subject as an added value compared to conventional braille devices. Different mappings between braille dots and actual tactile pins were implemented to match user needs. Performances of eight experienced braille readers were defined as the fraction of correct identifications of rendered content. Different information contents were tested (median performance on random strings, words, sentences identification was about 75%, 85%, 98%, respectively, with a significant increase, p < 0.01), obtaining statistically significant improvements in performance during the tests (p < 0.05). Experimental results, together with qualitative ratings provided by the subjects, show a good acceptance and the effectiveness of the proposed solution

  15. TACTILE RESPONSIVENESS PATTERNS AND THEIR ASSOCIATION WITH CORE FEATURES IN AUTISM SPECTRUM DISORDERS

    PubMed Central

    Foss-Feig, Jennifer H.; Heacock, Jessica L.; Cascio, Carissa J.

    2011-01-01

    Autism spectrum disorders (ASD) are often associated with aberrant responses to sensory stimuli, which are thought to contribute to the social, communication, and repetitive behavior deficits that define ASD. However, there are few studies that separate aberrant sensory responses by individual sensory modality to assess modality-specific associations between sensory features and core symptoms. Differences in response to tactile stimuli are prevalent in ASD, and tactile contact early in infancy is a foundation for the development of social and communication skills affected by ASD. We assessed the association between three aberrant patterns of tactile responsiveness (hyper-responsiveness, hypo-responsiveness, sensory seeking) and core symptoms of ASD. Both sensory and core features were measured with converging methods including both parent-report and direct observation. Our results demonstrate that for the tactile modality, sensory hypo-responsiveness correlates strongly with increased social and communication impairments, and to a lesser degree, repetitive behaviors. Sensory seeking was found to correlate strongly with social impairment, nonverbal communication impairment, and repetitive behaviors. Surprisingly, tactile hyper-responsiveness did not significantly correlate with any core features of ASD. This differential association between specific tactile processing patterns and core features provides an important step in defining the significance of sensory symptoms in ASD, and may be useful in the development of sensory–based approaches for early detection and intervention. PMID:22059092

  16. Spatially digitized tactile pressure sensors with tunable sensitivity and sensing range.

    PubMed

    Choi, Eunsuk; Sul, Onejae; Hwang, Soonhyung; Cho, Joonhyung; Chun, Hyunsuk; Kim, Hongjun; Lee, Seung-Beck

    2014-10-24

    When developing an electronic skin with touch sensation, an array of tactile pressure sensors with various ranges of pressure detection need to be integrated. This requires low noise, highly reliable sensors with tunable sensing characteristics. We demonstrate the operation of tactile pressure sensors that utilize the spatial distribution of contact electrodes to detect various ranges of tactile pressures. The device consists of a suspended elastomer diaphragm, with a carbon nanotube thin-film on the bottom, which makes contact with the electrodes on the substrate with applied pressure. The electrodes separated by set distances become connected in sequence with tactile pressure, enabling consecutive electrodes to produce a signal. Thus, the pressure is detected not by how much of a signal is produced but by which of the electrodes is registering an output. By modulating the diaphragm diameter, and suspension height, it was possible to tune the pressure sensitivity and sensing range. Also, adding a fingerprint ridge structure enabled the sensor to detect the periodicity of sub-millimeter grating patterns on a silicon wafer.

  17. GelSight: High-Resolution Robot Tactile Sensors for Estimating Geometry and Force

    PubMed Central

    Yuan, Wenzhen; Dong, Siyuan; Adelson, Edward H.

    2017-01-01

    Tactile sensing is an important perception mode for robots, but the existing tactile technologies have multiple limitations. What kind of tactile information robots need, and how to use the information, remain open questions. We believe a soft sensor surface and high-resolution sensing of geometry should be important components of a competent tactile sensor. In this paper, we discuss the development of a vision-based optical tactile sensor, GelSight. Unlike the traditional tactile sensors which measure contact force, GelSight basically measures geometry, with very high spatial resolution. The sensor has a contact surface of soft elastomer, and it directly measures its deformation, both vertical and lateral, which corresponds to the exact object shape and the tension on the contact surface. The contact force, and slip can be inferred from the sensor’s deformation as well. Particularly, we focus on the hardware and software that support GelSight’s application on robot hands. This paper reviews the development of GelSight, with the emphasis in the sensing principle and sensor design. We introduce the design of the sensor’s optical system, the algorithm for shape, force and slip measurement, and the hardware designs and fabrication of different sensor versions. We also show the experimental evaluation on the GelSight’s performance on geometry and force measurement. With the high-resolution measurement of shape and contact force, the sensor has successfully assisted multiple robotic tasks, including material perception or recognition and in-hand localization for robot manipulation. PMID:29186053

  18. Tactile cueing effects on performance in simulated aerial combat with high acceleration.

    PubMed

    van Erp, Jan B F; Eriksson, Lars; Levin, Britta; Carlander, Otto; Veltman, J A; Vos, Wouter K

    2007-12-01

    Recent evidence indicates that vibrotactile displays can potentially reduce the risk of sensory and cognitive overload. Before these displays can be introduced in super agile aircraft, it must be ascertained that vibratory stimuli can be sensed and interpreted by pilots subjected to high G loads. Each of 9 pilots intercepted 32 targets in the Swedish Dynamic Flight Simulator. Targets were indicated on simulated standard Gripen visual displays. In addition, in half of the trials target direction was also displayed on a 60-element tactile torso display. Performance measures and subjective ratings were recorded. Each pilot pulled G peaks above +8 Gz. With tactile cueing present, mean reaction time was reduced from 1458 ms (SE = 54) to 1245 ms (SE = 88). Mean total chase time for targets that popped up behind the pilot's aircraft was reduced from 13 s (SE = 0.45) to 12 s (SE = 0.41). Pilots rated the tactile display favorably over the visual displays at target pop-up on the easiness of detecting a threat presence and on the clarity of initial position of the threats. This study is the first to show that tactile display information is perceivable and useful in hypergravity (up to +9 Gz). The results show that the tactile display can capture attention at threat pop-up and improve threat awareness for threats in the back, even in the presence of high-end visual displays. It is expected that the added value of tactile displays may further increase after formal training and in situations of unexpected target pop-up.

  19. Acoustic Tactile Representation of Visual Information

    NASA Astrophysics Data System (ADS)

    Silva, Pubudu Madhawa

    Our goal is to explore the use of hearing and touch to convey graphical and pictorial information to visually impaired people. Our focus is on dynamic, interactive display of visual information using existing, widely available devices, such as smart phones and tablets with touch sensitive screens. We propose a new approach for acoustic-tactile representation of visual signals that can be implemented on a touch screen and allows the user to actively explore a two-dimensional layout consisting of one or more objects with a finger or a stylus while listening to auditory feedback via stereo headphones. The proposed approach is acoustic-tactile because sound is used as the primary source of information for object localization and identification, while touch is used for pointing and kinesthetic feedback. A static overlay of raised-dot tactile patterns can also be added. A key distinguishing feature of the proposed approach is the use of spatial sound (directional and distance cues) to facilitate the active exploration of the layout. We consider a variety of configurations for acoustic-tactile rendering of object size, shape, identity, and location, as well as for the overall perception of simple layouts and scenes. While our primary goal is to explore the fundamental capabilities and limitations of representing visual information in acoustic-tactile form, we also consider a number of relatively simple configurations that can be tied to specific applications. In particular, we consider a simple scene layout consisting of objects in a linear arrangement, each with a distinct tapping sound, which we compare to a ''virtual cane.'' We will also present a configuration that can convey a ''Venn diagram.'' We present systematic subjective experiments to evaluate the effectiveness of the proposed display for shape perception, object identification and localization, and 2-D layout perception, as well as the applications. Our experiments were conducted with visually blocked

  20. Tactile pavement for guiding walking direction: An assessment of heading direction and gait stability.

    PubMed

    Pluijter, Nanda; de Wit, Lieke P W; Bruijn, Sjoerd M; Plaisier, Myrthe A

    2015-10-01

    For maintaining heading direction while walking we heavily rely on vision. Therefore, walking in the absence of vision or with visual attention directed elsewhere potentially leads to dangerous situations. Here we investigated whether tactile information from the feet can be used as a (partial) substitute for vision in maintaining a stable heading direction. If so, participants should be better able to keep a constant heading direction on tactile pavement that indicates directionality than on regular flat pavement. However, such a pavement may also be destabilizing. Thus we asked participants to walk straight ahead on regular pavement, and on tactile pavement (tiles with ridges along the walking direction) while varying the amount of vision. We assessed the effects of the type of pavement as well as the amount of vision on the variability of the heading direction as well as gait stability. Both of these measures were calculated from accelerations and angular velocities recorded from a smartphone attached to the participants trunk. Results showed that on tactile pavement participants had a less variations in their heading direction than on regular pavement. The drawback, however, was that the tactile pavement used in this study decreased gait stability. In sum, tactile pavement can be used as a partial substitute for vision in maintaining heading direction, but it can also decrease gait stability. Future work should focus on designing tactile pavement that does provided directional clues, but is less destabilizing. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Artery cross-clamping during laparoscopic vascular surgeries; a computational tactile sensing approach.

    PubMed

    Pahlavan, Pedram; Najarian, Siamak; Afshari, Elnaz; Moini, Majid

    2013-01-01

    Artificial palpation is one of the most valuable achievements of artificial tactile sensing approach that can be used in various fields of medicine and more specifically in surgery. These techniques cause different surgical maneuvers to be done more precisely and noninvasively. In this study, considering the present problems and limitations of cross-clamping an artery during laparoscopic vascular surgeries, a new tactile sensory system will be introduced.Having imitated surgeon's palpation during open vascular surgeries and modeled it conceptually, the optimal amount of the total angular displacement of each robot joint in order to cross-clamping an artery without damaging to the artery surrounding tissues will be calculated. The elastic governing equation of contact occurred between the tactile sensor placed on the first link of the robot and the surrounding tissues around the artery were developed. A finite element model is coupled with genetic algorithm optimization method so that the normal stress and displacements in contact surface of the robot and artery's surrounding tissues would be minimized. Thus, reliability and accuracy of artificial tactile sensing method in artery cross-clamping will be demonstrated. Finally, the functional principles of the new tactile system capable of cross-clamping an artery during laparoscopic surgeries will be presented.

  2. Spatial cues serving the tactile directional sensibility of the human forearm.

    PubMed Central

    Norrsell, U; Olausson, H

    1994-01-01

    1. Tactile directional sensibility is considered to rely on the parallel processing of direction-contingent sensory data that depend on skin stretching caused by friction, and spatial cues that vary with time. A temperature-controlled airstream stimulus that prevented the activation of stretch receptors was used to investigate directional sensibility for the skin of the forearm. 2. The dependence on contact load and distance of movement was determined for normal subjects with a two-alternative forced-choice method. Testing was performed under two conditions, elbow bent or straight. Bracing the skin by straightening the arm did not alter the accuracy of the directional sensibility, in contrast to previous findings with stimuli that caused friction. 3. The accuracy of directional sensibility was correlated linearly to the logarithm of the distance of movement of the air jet. No correlation was found between accuracy and contact load, unlike findings with stimuli that cause friction. 4. Measurements were made with different subjects to determine the threshold distance at constant load. On average, subjects were able to distinguish direction with movements of < or = 8 mm. This acuity is sharper than has been reported with static stimuli. There was no correlation between subjects' threshold distances for judging direction and spatial acuity measured with absolute point localization. 5. The ability to distinguish direction was poor for the airstream stimulus compared with stimuli causing frictional contact with hairy skin. Nevertheless, the present findings are consistent with the suggestion that cutaneous spatial acuity is better for dynamic than for static stimuli. Images Figure 1 PMID:7965863

  3. Sulfasalazine Blocks the Development of Tactile Allodynia in Diabetic Rats

    PubMed Central

    Berti-Mattera, Liliana N.; Kern, Timothy S.; Siegel, Ruth E.; Nemet, Ina; Mitchell, Rochanda

    2008-01-01

    OBJECTIVE—Diabetic neuropathy is manifested either by loss of nociception (painless syndrome) or by mechanical hyperalgesia and tactile allodynia (pain in response to nonpainful stimuli). While therapies with vasodilators or neurotrophins reverse some functional and metabolic abnormalities in diabetic nerves, they only partially ameliorate neuropathic pain. The reported link between nociception and targets of the anti-inflammatory drug sulfasalazine prompted us to investigate its effect on neuropathic pain in diabetes. RESEARCH DESIGN AND METHODS—We examined the effects of sulfasalazine, salicylates, and the poly(ADP-ribose) polymerase-1 inhibitor PJ34 on altered nociception in streptozotocin-induced diabetic rats. We also evaluated the levels of sulfasalazine targets in sciatic nerves and dorsal root ganglia (DRG) of treated animals. Finally, we analyzed the development of tactile allodynia in diabetic mice lacking expression of the sulfasalazine target nuclear factor-κB (NF-κB) p50. RESULTS—Sulfasalazine completely blocked the development of tactile allodynia in diabetic rats, whereas relatively minor effects were observed with other salicylates and PJ34. Along with the behavioral findings, sciatic nerves and DRG from sulfasalazine-treated diabetic rats displayed a decrease in NF-κB p50 expression compared with untreated diabetic animals. Importantly, the absence of tactile allodynia in diabetic NF-κB p50−/− mice supported a role for NF-κB in diabetic neuropathy. Sulfasalazine treatment also increased inosine levels in sciatic nerves of diabetic rats. CONCLUSIONS—The complete inhibition of tactile allodynia in experimental diabetes by sulfasalazine may stem from its ability to regulate both NF-κB and inosine. Sulfasalazine might be useful in the treatment of nociceptive alterations in diabetic patients. PMID:18633115

  4. Lateralized ultradian rhythms: evidence from tactile discrimination of either hand.

    PubMed

    Meier-Koll, A

    1998-12-01

    Endogenous ultradian rhythms with periods of one or a few hours affect not only on physiological and behavioural functions but also perception and cognition. In particular, lateralized ultradian rhythms which seem to operate separately in the right and left hemispheres of the brain can be monitored by testing the tactile discrimination of the contralateral hand. The present paper is based on two subsequent studies: First, ultradian rhythms in tactile discrimination of either hand were examined in German subjects under laboratory conditions. Considerably different ultradian periods of right and left-handed tactile error rate were found in men but not in women. In a second study, a group of Kenyan Masai shepherds were tested while the subjects were leading herds on daily feeding routes through a savanna habitat. They showed ultradian periods of about 2 hours in tactile discrimination of either hand. Since the right hemisphere is specialized for visuospatial, the left for verbal processing lateralized ultradian rhythms may serve for a long-scale timing of neural processes underlying spatial and semantic mapping of the environment. Sex difference in German subjects and lateral differences found in left-handed (right-hemispheric) ultradian rhythms of German and Masai subjects are discussed from this point of view.

  5. Making your skin crawl: The role of tactile sensitivity in disease avoidance.

    PubMed

    Hunt, David Francis; Cannell, Grace; Davenhill, Nicholas A; Horsford, Stephanie A; Fleischman, Diana S; Park, Justin H

    2017-07-01

    Mounting evidence indicates that animals, including humans, have evolved a behavioral disease-avoidance system designed to facilitate the detection and avoidance of sources of pathogens, and that this system interacts with physiological defenses. The skin acts as an important anatomical barrier, yet little research has investigated the role of tactile sensitivity in disease avoidance. Increased tactile sensitivity in the presence of potential sources of pathogens may facilitate prophylactic behaviors such as self-grooming. Across multiple studies, we tested the hypothesis that the induction of disgust-the key emotion underlying disease avoidance-may lead to greater tactile sensitivity compared to control conditions. A nonsignificant trend was found in a pilot study, which was replicated (and found to be significant) in Studies 1 and 2. To our knowledge, these results are the first to demonstrate disgust-induced changes in tactile sensitivity, and they contribute to the growing literature on the integrated evolved defenses against infectious disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Anterior insula coordinates hierarchical processing of tactile mismatch responses

    PubMed Central

    Allen, Micah; Fardo, Francesca; Dietz, Martin J.; Hillebrandt, Hauke; Friston, Karl J.; Rees, Geraint; Roepstorff, Andreas

    2016-01-01

    The body underlies our sense of self, emotion, and agency. Signals arising from the skin convey warmth, social touch, and the physical characteristics of external stimuli. Surprising or unexpected tactile sensations can herald events of motivational salience, including imminent threats (e.g., an insect bite) and hedonic rewards (e.g., a caressing touch). Awareness of such events is thought to depend upon the hierarchical integration of body-related mismatch responses by the anterior insula. To investigate this possibility, we measured brain activity using functional magnetic resonance imaging, while healthy participants performed a roving tactile oddball task. Mass-univariate analysis demonstrated robust activations in limbic, somatosensory, and prefrontal cortical areas previously implicated in tactile deviancy, body awareness, and cognitive control. Dynamic Causal Modelling revealed that unexpected stimuli increased the strength of forward connections along a caudal to rostral hierarchy—projecting from thalamic and somatosensory regions towards insula, cingulate and prefrontal cortices. Within this ascending flow of sensory information, the AIC was the only region to show increased backwards connectivity to the somatosensory cortex, augmenting a reciprocal exchange of neuronal signals. Further, participants who rated stimulus changes as easier to detect showed stronger modulation of descending PFC to AIC connections by deviance. These results suggest that the AIC coordinates hierarchical processing of tactile prediction error. They are interpreted in support of an embodied predictive coding model where AIC mediated body awareness is involved in anchoring a global neuronal workspace. PMID:26584870

  7. Pure Amorphagnosia without Tactile Object Agnosia

    PubMed Central

    Kubota, Shinichirou; Yamada, Mai; Satoh, Hideyo; Satoh, Akira; Tsujihata, Mitsuhiro

    2017-01-01

    A 54-year-old female showed amorphagnosia without ahylognosia and tactile agnosia 40 days after the onset of right cerebral infarction. Her basic somatosensory functions were normal. The appreciation of substance qualities (hylognosia) was preserved, but the patient's inability to recognize the size and shape (morphagnosia) was confined to 2- and 3-dimensional shapes (amorphagnosia) in the left hand. However, the patient's ability to recognize real daily objects was well preserved. Brain MRI after admission showed ischemic lesions confined to the right pre- and postcentral gyri and the medial frontal cortex on DWI and FLAIR images. An analysis of SPECT images revealed that the most decreased areas were localized to the pre- and postcentral gyri, superior and inferior parietal lobules, supramarginal gyrus, and angular gyrus. Considering the previous reported cases, the responsible lesion for the impaired perception of hylognosia and morphagnosia may not necessarily be confined to the right hemisphere. To date, 5 reports (6 cases) of tactile agnosia have been published; 4 cases presented with both ahylognosia and amorphagnosia, while 1 presented with only amorphagnosia, and another showed amorphagnosia and mild ahylognosia. Our case is the first to present with only amorphagnosia without tactile agnosia. The mechanism for the well-preserved recognition of real objects may depend on the preserved hylognosia. Of note, there have been no reports showing only ahylognosia without amorphagnosia. Further studies are necessary to clarify whether or not patients with preserved hylognosia or morphagnosia retain the ability to perceive real objects. PMID:28559827

  8. Topographic generalization of tactile perceptual learning.

    PubMed

    Harrar, Vanessa; Spence, Charles; Makin, Tamar R

    2014-02-01

    Perceptual learning can improve our sensory abilities. Understanding its underlying mechanisms, in particular, when perceptual learning generalizes, has become a focus of research and controversy. Specifically, there is little consensus regarding the extent to which tactile perceptual learning generalizes across fingers. We measured tactile orientation discrimination abilities on 4 fingers (index and middle fingers of both hands), using psychophysical measures, before and after 4 training sessions on 1 finger. Given the somatotopic organization of the hand representation in the somatosensory cortex, the topography of the cortical areas underlying tactile perceptual learning can be inferred from the pattern of generalization across fingers; only fingers sharing cortical representation with the trained finger ought to improve with it. Following training, performance improved not only for the trained finger but also for its adjacent and homologous fingers. Although these fingers were not exposed to training, they nevertheless demonstrated similar levels of learning as the trained finger. Conversely, the performance of the finger that was neither adjacent nor homologous to the trained finger was unaffected by training, despite the fact that our procedure was designed to enhance generalization, as described in recent visual perceptual learning research. This pattern of improved performance is compatible with previous reports of neuronal receptive fields (RFs) in the primary somatosensory cortex (SI) spanning adjacent and homologous digits. We conclude that perceptual learning rooted in low-level cortex can still generalize, and suggest potential applications for the neurorehabilitation of syndromes associated with maladaptive plasticity in SI. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Tactile Instrument for Aviation

    DTIC Science & Technology

    2000-07-30

    response times using 8 tactor locations was repeated with a dual memory /tracking task or an air combat simulation to evaluate the effectiveness of the...Global Positioning/Inertial Navigation System technologies into a single system for evaluation in an UH-60 Helicopter. A 10-event test operation was... evaluation of the following technology areas need to be pursued: • Integration of tactile instruments with helmet mounted displays and 3D audio displays

  10. A long-lasting improvement of tactile extinction after galvanic vestibular stimulation: two Sham-stimulation controlled case studies.

    PubMed

    Kerkhoff, Georg; Hildebrandt, Helmut; Reinhart, Stefan; Kardinal, Mareike; Dimova, Violeta; Utz, Kathrin S

    2011-01-01

    Sensory extinction is frequent and often persistent after brain damage. Previous studies have shown the transient influence of sensory stimulation on tactile extinction. In the present two case studies we investigated whether subliminal galvanic vestibular stimulation (GVS) modulates tactile extinction. GVS induces polarity-specific changes in cerebral excitability in the vestibular cortices and adjacent cortical areas in the temporo-parietal cortex via polarization of the vestibular nerves. Two patients (DL, CJ) with left-sided tactile extinction due to chronic (5 vs. 6 (1/2) years lesion age) right-hemisphere lesions (right fronto-parietal in DL, right frontal and discrete parietal in CJ) were examined. Both showed normal tactile sensitivity to light touch and yielded 90-100% correct identifications in unilateral tactile stimulations for both hands. In Baseline investigations without GVS and Sham-GVS both showed stable left-sided tactile extinction rates of 40-55% (DL) and 49-72% (CJ). In contrast, one session of right-cathodal GVS (intensity: 0.6 mA, duration: 20 min) permanently improved tactile identification of identical stimuli, while a second session with left-cathodal GVS significantly reduced left-sided extinction rates for different stimuli in DL. Patient CJ's left-sided tactile extinction was significantly improved by left-cathodal GVS (0.5 mA, 20 min) for different stimuli, while right-cathodal GVS induced a significant reduction for identical materials. In contrast, Sham-stimulation was ineffective. Improvements remained stable for at least 1 year (DL) resp. 3 weeks (CJ). Control experiments ruled out improvements in tactile extinction merely by retesting. In conclusion, chronic tactile extinction may be permanently improved by GVS in a polarity-specific way. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Tactile Sun: Bringing an Invisible Universe to the Visually Impaired

    NASA Astrophysics Data System (ADS)

    Isidro, G. M.; Pantoja, C. A.

    2014-07-01

    A tactile model of the Sun has been created as a strategy for communicating astronomy to the blind or visually impaired, and as a useful outreach tool for general audiences. The model design was a collaboration between an education specialist, an astronomy specialist and a sculptor. The tactile Sun has been used at astronomy outreach events in Puerto Rico to make activities more inclusive and to increase public awareness of the needs of those with disabilities.

  12. Development of a biomimetic roughness sensor for tactile information with an elastomer

    NASA Astrophysics Data System (ADS)

    Choi, Jae-Young; Kim, Sung Joon; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, Ja Choon

    2016-04-01

    Human uses various sensational information for identifying an object. When contacting an unidentified object with no vision, tactile sensation provides a variety of information to perceive. Tactile sensation plays an important role to recognize a shape of surfaces from touching. In robotic fields, tactile sensation is especially meaningful. Robots can perform more accurate job using comprehensive tactile information. And in case of using sensors made by soft material like silicone, sensors can be used in various situations. So we are developing a tactile sensor with soft materials. As the conventional robot operates in a controlled environment, it is a good model to make robots more available at any circumstance that sensory systems of living things. For example, there are lots of mechanoreceptors that each of them has different roles detecting simulation in side of human skin tissue. By mimicking the mechanoreceptor, a sensory system can be realized more closely to human being. It is known that human obtains roughness information through scanning the surface with fingertips. During that times, subcutaneous mechanoreceptors detect vibration. In the same way, while a robot is scanning a surface of object, a roughness sensor developed detects vibrations generated between contacting two surfaces. In this research, a roughness sensor made by an elastomer was developed and experiment for perception of objects was conducted. We describe means to compare the roughness of objects with a newly developed sensor.

  13. Biologically inspired multi-layered synthetic skin for tactile feedback in prosthetic limbs.

    PubMed

    Osborn, Luke; Nguyen, Harrison; Betthauser, Joseph; Kaliki, Rahul; Thakor, Nitish

    2016-08-01

    The human body offers a template for many state-of-the-art prosthetic devices and sensors. In this work, we present a novel, sensorized synthetic skin that mimics the natural multi-layered nature of mechanoreceptors found in healthy glabrous skin to provide tactile information. The multi-layered sensor is made up of flexible piezoresistive textiles that act as force sensitive resistors (FSRs) to convey tactile information, which are embedded within a silicone rubber to resemble the compliant nature of human skin. The top layer of the synthetic skin is capable of detecting small loads less than 5 N whereas the bottom sensing layer responds reliably to loads over 7 N. Finite element analysis (FEA) of a simplified human fingertip and the synthetic skin was performed. Results suggest similarities in behavior during loading. A natural tactile event is simulated by loading the synthetic skin on a prosthetic limb. Results show the sensors' ability to detect applied loads as well as the ability to simulate neural spiking activity based on the derivative and temporal differences of the sensor response. During the tactile loading, the top sensing layer responded 0.24 s faster than the bottom sensing layer. A synthetic biologically-inspired skin such as this will be useful for enhancing the functionality of prosthetic limbs through tactile feedback.

  14. Assessment of Dementia in Individuals with Dual Sensory Loss: Application of a Tactile Test Battery

    PubMed Central

    Bruhn, Peter; Dammeyer, Jesper

    2018-01-01

    Background/Aims Individuals with dual sensory loss (DSL) are more likely to experience cognitive decline with age than individuals without sensory loss. Other studies have pointed to the challenges in assessing cognitive abilities in individuals with DSL, as most existing instruments rely on use of vision and hearing. The aim of this study was to develop and evaluate a Tactile Test Battery (TTB) for cognitive assessment in individuals with DSL. Method Twenty elderly individuals with DSL, 20 with diagnosed dementia, and 20 without dementia or DSL (controls) completed the following tactile tests developed for the present study: Spatial learning, Spatial recall, Tactile form board, Clock reading, and Naming. The participants with dementia and controls also completed the Mini-Mental State Examination (MMSE). Results Overall, participants with dementia performed significantly worse on the tactile tests than participants with DSL and control participants. No significant differences on the tactile tests were found between participants with DSL and controls. The TTB and MMSE scores correlated significantly. Conclusion The findings from this study of applying tactile tests for cognitive examination in individuals with DSL are promising. They indicate that symptoms of dementia can be differentiated from symptoms related to DSL. PMID:29515619

  15. Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices.

    PubMed

    Mun, Seongcheol; Yun, Sungryul; Nam, Saekwang; Park, Seung Koo; Park, Suntak; Park, Bong Je; Lim, Jeong Mook; Kyung, Ki-Uk

    2018-01-01

    This paper reports soft actuator based tactile stimulation interfaces applicable to wearable devices. The soft actuator is prepared by multi-layered accumulation of thin electro-active polymer (EAP) films. The multi-layered actuator is designed to produce electrically-induced convex protrusive deformation, which can be dynamically programmable for wide range of tactile stimuli. The maximum vertical protrusion is and the output force is up to 255 mN. The soft actuators are embedded into the fingertip part of a glove and front part of a forearm band, respectively. We have conducted two kinds of experiments with 15 subjects. Perceived magnitudes of actuator's protrusion and vibrotactile intensity were measured with frequency of 1 Hz and 191 Hz, respectively. Analysis of the user tests shows participants perceive variation of protrusion height at the finger pad and modulation of vibration intensity through the proposed soft actuator based tactile interface.

  16. Computational Intelligence Techniques for Tactile Sensing Systems

    PubMed Central

    Gastaldo, Paolo; Pinna, Luigi; Seminara, Lucia; Valle, Maurizio; Zunino, Rodolfo

    2014-01-01

    Tactile sensing helps robots interact with humans and objects effectively in real environments. Piezoelectric polymer sensors provide the functional building blocks of the robotic electronic skin, mainly thanks to their flexibility and suitability for detecting dynamic contact events and for recognizing the touch modality. The paper focuses on the ability of tactile sensing systems to support the challenging recognition of certain qualities/modalities of touch. The research applies novel computational intelligence techniques and a tensor-based approach for the classification of touch modalities; its main results consist in providing a procedure to enhance system generalization ability and architecture for multi-class recognition applications. An experimental campaign involving 70 participants using three different modalities in touching the upper surface of the sensor array was conducted, and confirmed the validity of the approach. PMID:24949646

  17. Computational intelligence techniques for tactile sensing systems.

    PubMed

    Gastaldo, Paolo; Pinna, Luigi; Seminara, Lucia; Valle, Maurizio; Zunino, Rodolfo

    2014-06-19

    Tactile sensing helps robots interact with humans and objects effectively in real environments. Piezoelectric polymer sensors provide the functional building blocks of the robotic electronic skin, mainly thanks to their flexibility and suitability for detecting dynamic contact events and for recognizing the touch modality. The paper focuses on the ability of tactile sensing systems to support the challenging recognition of certain qualities/modalities of touch. The research applies novel computational intelligence techniques and a tensor-based approach for the classification of touch modalities; its main results consist in providing a procedure to enhance system generalization ability and architecture for multi-class recognition applications. An experimental campaign involving 70 participants using three different modalities in touching the upper surface of the sensor array was conducted, and confirmed the validity of the approach.

  18. A slow-adapting microfluidic-based tactile sensor

    NASA Astrophysics Data System (ADS)

    Tseng, W.-Y.; Fisher, J. S.; Prieto, J. L.; Rinaldi, K.; Alapati, G.; Lee, A. P.

    2009-08-01

    We present a microfluidic-based tactile sensor mimicking the human slow-adapting mechanoreceptor such as Merkel's disc. The sensor is composed of a polyimide (PI)/polydimethylsiloxane (PDMS) multilayer structure. The device uses a hemispherical reservoir filled with electrolyte solution in the PDMS layer, a microchannel in the PI layer and a pair of sensing electrodes below the microchannel as the force transducer. The tactile signal is detected as the impedance change resulting predominantly from the resistance variance due to the electrodes coverage by the 1M NaCl solution and is measured across the electrode pair. The sensor response is linear and the working range is shown to be in the range of 0-1.8 N. The characterization results also demonstrate the sensing of various levels of forces and its long-term signal stability.

  19. Stiffness mapping prostate biopsy samples using a tactile sensor.

    PubMed

    Peng, Qiyu; Omata, Sadao; Peehl, Donna M; Constantinou, Chris E

    2011-01-01

    Previous studies have demonstrated that the stiffness of cancerous cells reflects their pathological stage and progression rates, with increased cancerous cell stiffness associated with increased aggressiveness. Therefore, the elasticity of the cancerous cells has the potential to be used as an indicator of the cancer's aggressiveness. However, the sensitivity and resolution of current palpation and imaging techniques are not sufficient to detect small cancerous tissues. In previous studies, we developed a tactile-based device to map with high resolution the stiffness of a tissue section. The purpose of this study is to evaluate this device using different tissues (BPH, Cancer and PZ) collected from human prostates. The preliminary results show that the tactile device is sensitive enough to tell the differences of the stiffness of different tissues. The results also disclosed the factors (humidity, temperature and tissue degradation) which could dramatically affect the results of stiffness mapping. The tactile technology described in this paper has the potential to help disclose the underlying mechanical mechanisms that lead to increased stiffness in prostate tumors.

  20. Bioinspired active whisker sensor for robotic vibrissal tactile sensing

    NASA Astrophysics Data System (ADS)

    Ju, Feng; Ling, Shih-Fu

    2014-12-01

    A whisker transducer (WT) inspired by rat’s vibrissal tactile perception is proposed based on a transduction matrix model characterizing the electro-mechanical transduction process in both forward and backward directions. It is capable of acting as an actuator to sweep the whisker and simultaneously as a sensor to sense the force, motion, and mechanical impedance at whisker tip. Its validity is confirmed by numerical simulation using a finite element model. A prototype is then fabricated and its transduction matrix is determined by parameter identification. The calibrated WT can accurately sense mechanical impedance which is directly related to stiffness, mass and damping. Subsequent vibrissal tactile sensing of sandpaper texture reveals that the real part of mechanical impedance sensed by WT is correlated with sandpaper roughness. Texture discrimination is successfully achieved by inputting the real part to a k-means clustering algorithm. The mechanical impedance sensing ability as well as other features of the WT such as simultaneous-actuation-and-sensing makes it a good solution to robotic tactile sensing.

  1. Tactile Data Entry for Extravehicular Activity

    NASA Technical Reports Server (NTRS)

    Adams, Richard J.; Olowin, Aaron B.; Hannaford, Blake; Sands, O Scott

    2012-01-01

    In the task-saturated environment of extravehicular activity (EVA), an astronaut's ability to leverage suit-integrated information systems is limited by a lack of options for data entry. In particular, bulky gloves inhibit the ability to interact with standard computing interfaces such as a mouse or keyboard. This paper presents the results of a preliminary investigation into a system that permits the space suit gloves themselves to be used as data entry devices. Hand motion tracking is combined with simple finger gesture recognition to enable use of a virtual keyboard, while tactile feedback provides touch-based context to the graphical user interface (GUI) and positive confirmation of keystroke events. In human subject trials, conducted with twenty participants using a prototype system, participants entered text significantly faster with tactile feedback than without (p = 0.02). The results support incorporation of vibrotactile information in a future system that will enable full touch typing and general mouse interactions using instrumented EVA gloves.

  2. Now You Feel both: Galvanic Vestibular Stimulation Induces Lasting Improvements in the Rehabilitation of Chronic Tactile Extinction

    PubMed Central

    Schmidt, Lena; Utz, Kathrin S.; Depper, Lena; Adams, Michaela; Schaadt, Anna-Katharina; Reinhart, Stefan; Kerkhoff, Georg

    2013-01-01

    Tactile extinction is frequent, debilitating, and often persistent after brain damage. Currently, there is no treatment available for this disorder. In two previous case studies we showed an influence of galvanic vestibular stimulation (GVS) on tactile extinction. Here, we evaluated in further patients the immediate and lasting effects of GVS on tactile extinction. GVS is known to induce polarity-specific changes in cerebral excitability in the vestibular cortices and adjacent cortical areas. Tactile extinction was examined with the Quality Extinction Test (QET) where subjects have to discriminate six different tactile fabrics in bilateral, double simultaneous stimulations on their dorsum of hands with identical or different tactile fabrics. Twelve patients with stable left-sided tactile extinction after unilateral right-hemisphere lesions were divided into two groups. The GVS group (N = 6) performed the QET under six different experimental conditions (two Baselines, Sham-GVS, left-cathodal/right-anodal GVS, right-cathodal/left-anodal GVS, and a Follow-up test). The second group of patients with left-sided extinction (N = 6) performed the QET six times repetitively, but without receiving GVS (control group). Both right-cathodal/left-anodal as well as left-cathodal/right-anodal GVS (mean: 0.7 mA) improved tactile identification of identical and different stimuli in the experimental group. These results show a generic effect of GVS on tactile extinction, but not in a polarity-specific way. These observed effects persisted at follow-up. Sham-GVS had no significant effect on extinction. In the control group, no significant improvements were seen in the QET after the six measurements of the QET, thus ruling out test repetition effects. In conclusion, GVS improved bodily awareness permanently for the contralesional body side in patients with tactile extinction and thus offers a novel treatment option for these patients. PMID:23519604

  3. Tactile feedback to the palm using arbitrarily shaped DEA

    NASA Astrophysics Data System (ADS)

    Mößinger, Holger; Haus, Henry; Kauer, Michaela; Schlaak, Helmut F.

    2014-03-01

    Tactile stimulation enhances user experience and efficiency in human machine interaction by providing information via another sensory channel to the human brain. DEA as tactile interfaces have been in the focus of research in recent years. Examples are (vibro-) tactile keyboards or Braille displays. These applications of DEA focus mainly on interfacing with the user's fingers or fingertips only - demonstrating the high spatial resolution achievable with DEA. Besides providing a high resolution, the flexibility of DEA also allows designing free form surfaces equipped with single actuators or actuator matrices which can be fitted to the surface of the human skin. The actuators can then be used to provide tactile stimuli to different areas of the body, not to the fingertips only. Utilizing and demonstrating this flexibility we designed a free form DEA pad shaped to fit into the inside of the human palm. This pad consists of four single actuators which can provide e.g. directional information such as left, right, up and down. To demonstrate the value of such free form actuators we manufactured a PC-mouse using 3d printing processes. The actuator pad is mounted on the back of the mouse, resting against the palm while operating it. Software on the PC allows control of the vibration patterns displayed by the actuators. This allows helping the user by raising attention to certain directions or by discriminating between different modes like "pick" or "manipulate". Results of first tests of the device show an improved user experience while operating the PC mouse.

  4. An Extreme Learning Machine-Based Neuromorphic Tactile Sensing System for Texture Recognition.

    PubMed

    Rasouli, Mahdi; Chen, Yi; Basu, Arindam; Kukreja, Sunil L; Thakor, Nitish V

    2018-04-01

    Despite significant advances in computational algorithms and development of tactile sensors, artificial tactile sensing is strikingly less efficient and capable than the human tactile perception. Inspired by efficiency of biological systems, we aim to develop a neuromorphic system for tactile pattern recognition. We particularly target texture recognition as it is one of the most necessary and challenging tasks for artificial sensory systems. Our system consists of a piezoresistive fabric material as the sensor to emulate skin, an interface that produces spike patterns to mimic neural signals from mechanoreceptors, and an extreme learning machine (ELM) chip to analyze spiking activity. Benefiting from intrinsic advantages of biologically inspired event-driven systems and massively parallel and energy-efficient processing capabilities of the ELM chip, the proposed architecture offers a fast and energy-efficient alternative for processing tactile information. Moreover, it provides the opportunity for the development of low-cost tactile modules for large-area applications by integration of sensors and processing circuits. We demonstrate the recognition capability of our system in a texture discrimination task, where it achieves a classification accuracy of 92% for categorization of ten graded textures. Our results confirm that there exists a tradeoff between response time and classification accuracy (and information transfer rate). A faster decision can be achieved at early time steps or by using a shorter time window. This, however, results in deterioration of the classification accuracy and information transfer rate. We further observe that there exists a tradeoff between the classification accuracy and the input spike rate (and thus energy consumption). Our work substantiates the importance of development of efficient sparse codes for encoding sensory data to improve the energy efficiency. These results have a significance for a wide range of wearable, robotic

  5. First Person Perspective of Seated Participants Over a Walking Virtual Body Leads to Illusory Agency Over the Walking.

    PubMed

    Kokkinara, Elena; Kilteni, Konstantina; Blom, Kristopher J; Slater, Mel

    2016-07-01

    Agency, the attribution of authorship to an action of our body, requires the intention to carry out the action, and subsequently a match between its predicted and actual sensory consequences. However, illusory agency can be generated through priming of the action together with perception of bodily action, even when there has been no actual corresponding action. Here we show that participants can have the illusion of agency over the walking of a virtual body even though in reality they are seated and only allowed head movements. The experiment (n = 28) had two factors: Perspective (1PP or 3PP) and Head Sway (Sway or NoSway). Participants in 1PP saw a life-sized virtual body spatially coincident with their own from a first person perspective, or the virtual body from third person perspective (3PP). In the Sway condition the viewpoint included a walking animation, but not in NoSway. The results show strong illusions of body ownership, agency and walking, in the 1PP compared to the 3PP condition, and an enhanced level of arousal while the walking was up a virtual hill. Sway reduced the level of agency. We conclude with a discussion of the results in the light of current theories of agency.

  6. Artificial Roughness Encoding with a Bio-inspired MEMS- based Tactile Sensor Array

    PubMed Central

    Oddo, Calogero Maria; Beccai, Lucia; Felder, Martin; Giovacchini, Francesco; Carrozza, Maria Chiara

    2009-01-01

    A compliant 2×2 tactile sensor array was developed and investigated for roughness encoding. State of the art cross shape 3D MEMS sensors were integrated with polymeric packaging providing in total 16 sensitive elements to external mechanical stimuli in an area of about 20 mm2, similarly to the SA1 innervation density in humans. Experimental analysis of the bio-inspired tactile sensor array was performed by using ridged surfaces, with spatial periods from 2.6 mm to 4.1 mm, which were indented with regulated 1N normal force and stroked at constant sliding velocity from 15 mm/s to 48 mm/s. A repeatable and expected frequency shift of the sensor outputs depending on the applied stimulus and on its scanning velocity was observed between 3.66 Hz and 18.46 Hz with an overall maximum error of 1.7%. The tactile sensor could also perform contact imaging during static stimulus indentation. The experiments demonstrated the suitability of this approach for the design of a roughness encoding tactile sensor for an artificial fingerpad. PMID:22412304

  7. Functionalization of Tactile Sensation for Robot Based on Haptograph and Modal Decomposition

    NASA Astrophysics Data System (ADS)

    Yokokura, Yuki; Katsura, Seiichiro; Ohishi, Kiyoshi

    In the real world, robots should be able to recognize the environment in order to be of help to humans. A video camera and a laser range finder are devices that can help robots recognize the environment. However, these devices cannot obtain tactile information from environments. Future human-assisting-robots should have the ability to recognize haptic signals, and a disturbance observer can possibly be used to provide the robot with this ability. In this study, a disturbance observer is employed in a mobile robot to functionalize the tactile sensation. This paper proposes a method that involves the use of haptograph and modal decomposition for the haptic recognition of road environments. The haptograph presents a graphic view of the tactile information. It is possible to classify road conditions intuitively. The robot controller is designed by considering the decoupled modal coordinate system, which consists of translational and rotational modes. Modal decomposition is performed by using a quarry matrix. Once the robot is provided with the ability to recognize tactile sensations, its usefulness to humans will increase.

  8. A flexible tactile-feedback touch screen using transparent ferroelectric polymer film vibrators

    NASA Astrophysics Data System (ADS)

    Ju, Woo-Eon; Moon, Yong-Ju; Park, Cheon-Ho; Choi, Seung Tae

    2014-07-01

    To provide tactile feedback on flexible touch screens, transparent relaxor ferroelectric polymer film vibrators were designed and fabricated in this study. The film vibrator can be integrated underneath a transparent cover film or glass, and can also produce acoustic waves that cause a tactile sensation on human fingertips. Poly(vinylidene fluoride-trifluoroethylene-chlorotrifluoroethylene) [P(VDF-TrFE-CTFE)] polymer was used as the relaxor ferroelectric polymer because it produces a large strain under applied electric fields, shows a fast response, and has excellent optical transparency. The natural frequency of this tactile-feedback touch screen was designed to be around 200-240 Hz, at which the haptic perception of human fingertips is the most sensitive; therefore, the resonance of the touch screen at its natural frequency provides maximum haptic sensation. A multilayered relaxor ferroelectric polymer film vibrator was also demonstrated to provide the same vibration power at reduced voltage. The flexible P(VDF-TrFE-CTFE) film vibrators developed in this study are expected to provide tactile sensation not only in large-area flat panel displays, but also in flexible displays and touch screens.

  9. Symbol recognition produced by points of tactile stimulation: the illusion of linear continuity.

    PubMed

    Gonzales, G R

    1996-11-01

    To determine whether tactile receptive communication is possible through the use of a mechanical device that produces the phi phenomenon on the body surface. Twenty-six subjects (11 blind and 15 sighted participants) were tested with use of a tactile communication device (TCD) that produces an illusion of linear continuity forming numbers on the dorsal aspect of the wrist. Recognition of a number or number set was the goal. A TCD with protruding and vibrating solenoids produced sequentially delivered points of cutaneous stimulation along a pattern resembling numbers and created the illusion of dragging a vibrating stylet to form numbers, similar to what might be felt by testing for graphesthesia. Blind subjects recognized numbers with fewer trials than did sighted subjects, although all subjects were able to recognize all the numbers produced by the TCD. Subjects who had been blind since birth and had no prior tactile exposure to numbers were able to draw the numbers after experiencing them delivered by the TCD even though they did not recognize their meaning. The phi phenomenon is probably responsible for the illusion of continuous lines in the shape of numbers as produced by the TCD. This tactile illusion could potentially be used for more complex tactile communications such as letters and words.

  10. Differences in Early Stages of Tactile ERP Temporal Sequence (P100) in Cortical Organization during Passive Tactile Stimulation in Children with Blindness and Controls.

    PubMed

    Ortiz Alonso, Tomás; Santos, Juan Matías; Ortiz Terán, Laura; Borrego Hernández, Mayelin; Poch Broto, Joaquín; de Erausquin, Gabriel Alejandro

    2015-01-01

    Compared to their seeing counterparts, people with blindness have a greater tactile capacity. Differences in the physiology of object recognition between people with blindness and seeing people have been well documented, but not when tactile stimuli require semantic processing. We used a passive vibrotactile device to focus on the differences in spatial brain processing evaluated with event related potentials (ERP) in children with blindness (n = 12) vs. normally seeing children (n = 12), when learning a simple spatial task (lines with different orientations) or a task involving recognition of letters, to describe the early stages of its temporal sequence (from 80 to 220 msec) and to search for evidence of multi-modal cortical organization. We analysed the P100 of the ERP. Children with blindness showed earlier latencies for cognitive (perceptual) event related potentials, shorter reaction times, and (paradoxically) worse ability to identify the spatial direction of the stimulus. On the other hand, they are equally proficient in recognizing stimuli with semantic content (letters). The last observation is consistent with the role of P100 on somatosensory-based recognition of complex forms. The cortical differences between seeing control and blind groups, during spatial tactile discrimination, are associated with activation in visual pathway (occipital) and task-related association (temporal and frontal) areas. The present results show that early processing of tactile stimulation conveying cross modal information differs in children with blindness or with normal vision.

  11. Differences in Early Stages of Tactile ERP Temporal Sequence (P100) in Cortical Organization during Passive Tactile Stimulation in Children with Blindness and Controls

    PubMed Central

    Ortiz Alonso, Tomás; Santos, Juan Matías; Ortiz Terán, Laura; Borrego Hernández, Mayelin; Poch Broto, Joaquín; de Erausquin, Gabriel Alejandro

    2015-01-01

    Compared to their seeing counterparts, people with blindness have a greater tactile capacity. Differences in the physiology of object recognition between people with blindness and seeing people have been well documented, but not when tactile stimuli require semantic processing. We used a passive vibrotactile device to focus on the differences in spatial brain processing evaluated with event related potentials (ERP) in children with blindness (n = 12) vs. normally seeing children (n = 12), when learning a simple spatial task (lines with different orientations) or a task involving recognition of letters, to describe the early stages of its temporal sequence (from 80 to 220 msec) and to search for evidence of multi-modal cortical organization. We analysed the P100 of the ERP. Children with blindness showed earlier latencies for cognitive (perceptual) event related potentials, shorter reaction times, and (paradoxically) worse ability to identify the spatial direction of the stimulus. On the other hand, they are equally proficient in recognizing stimuli with semantic content (letters). The last observation is consistent with the role of P100 on somatosensory-based recognition of complex forms. The cortical differences between seeing control and blind groups, during spatial tactile discrimination, are associated with activation in visual pathway (occipital) and task-related association (temporal and frontal) areas. The present results show that early processing of tactile stimulation conveying cross modal information differs in children with blindness or with normal vision. PMID:26225827

  12. [Advances in the research of function of Merkel cells in tactile formation of skin].

    PubMed

    You, X; Wei, Z R

    2018-01-20

    Skin is the largest sense organ of human, with many mechanoreceptor cells under epidermis or dermis of skin and Merkel cell is one of them. It has been confirmed that Merkel cells play an important role in the process of mechanical transmission of mammalian soft tactile stimulation. Researches showed that Merkel cells had close relation to tactile formation and functioned by Merkel cell-neurite complexes and ion channels Piezo2. This article reviews Merkel cells and the function, problem and prospect of Merkel cells in tactile formation.

  13. Attenuating illusory binding with TMS of the right parietal cortex

    PubMed Central

    Esterman, Michael; Verstynen, Timothy; Robertson, Lynn C.

    2007-01-01

    A number of neuroimaging and neuropsychology studies have implicated various regions of parietal cortex as playing a critical role in the binding of color and form into conjunctions. The current study investigates the role of two such regions by examining how parietal transcranial magnetic stimulation (TMS) influences binding errors known as ‘illusory conjunctions.’ Participants made fewer binding errors after 1 Hz rTMS of the right intraparietal sulcus (IPS), while basic perception of features (colors and shape) was unaffected. No perceptual effects were found following left IPS stimulation, or stimulation of the right angular gyrus at the junction of the transverse occipital sulcus (IPS/TOS). These results support a role for the parietal cortex in feature binding but in ways that may require rethinking. PMID:17336097

  14. Illusory Changes in Body Size Modulate Body Satisfaction in a Way That Is Related to Non-Clinical Eating Disorder Psychopathology

    PubMed Central

    Preston, Catherine; Ehrsson, H. Henrik

    2014-01-01

    Historically, body size overestimation has been linked to abnormal levels of body dissatisfaction found in eating disorders. However, recently this relationship has been called into question. Indeed, despite a link between how we perceive and how we feel about our body seeming intuitive, until now lack of an experimental method to manipulate body size has meant that a causal link, even in healthy participants, has remained elusive. Recent developments in body perception research demonstrate that the perceptual experience of the body can be readily manipulated using multisensory illusions. The current study exploits such illusions to modulate perceived body size in an attempt to influence body satisfaction. Participants were presented with stereoscopic video images of slimmer and wider mannequin bodies viewed through head-mounted displays from first person perspective. Illusory ownership was induced by synchronously stroking the seen mannequin body with the unseen real body. Pre and post-illusion affective and perceptual measures captured changes in perceived body size and body satisfaction. Illusory ownership of a slimmer body resulted in participants perceiving their actual body as slimmer and giving higher ratings of body satisfaction demonstrating a direct link between perceptual and affective body representations. Change in body satisfaction following illusory ownership of a wider body, however, was related to degree of (non-clinical) eating disorder psychopathology, which can be linked to fluctuating body representations found in clinical samples. The results suggest that body perception is linked to body satisfaction and may be of importance for eating disorder symptomology. PMID:24465698

  15. Integration of Hand and Finger Location in External Spatial Coordinates for Tactile Localization

    ERIC Educational Resources Information Center

    Heed, Tobias; Backhaus, Jenny; Roder, Brigitte

    2012-01-01

    Tactile stimulus location is automatically transformed from somatotopic into external spatial coordinates, rendering information about the location of touch in three-dimensional space. This process is referred to as tactile remapping. Whereas remapping seems to occur automatically for the hands and feet, the fingers may constitute an exception in…

  16. Tactile feedback for relief of deafferentation pain using virtual reality system: a pilot study.

    PubMed

    Sano, Yuko; Wake, Naoki; Ichinose, Akimichi; Osumi, Michihiro; Oya, Reishi; Sumitani, Masahiko; Kumagaya, Shin-Ichiro; Kuniyoshi, Yasuo

    2016-06-28

    Previous studies have tried to relieve deafferentation pain (DP) by using virtual reality rehabilitation systems. However, the effectiveness of multimodal sensory feedback was not validated. The objective of this study is to relieve DP by neurorehabilitation using a virtual reality system with multimodal sensory feedback and to validate the efficacy of tactile feedback on immediate pain reduction. We have developed a virtual reality rehabilitation system with multimodal sensory feedback and applied it to seven patients with DP caused by brachial plexus avulsion or arm amputation. The patients executed a reaching task using the virtual phantom limb manipulated by their real intact limb. The reaching task was conducted under two conditions: one with tactile feedback on the intact hand and one without. The pain intensity was evaluated through a questionnaire. We found that the task with the tactile feedback reduced DP more (41.8 ± 19.8 %) than the task without the tactile feedback (28.2 ± 29.5 %), which was supported by a Wilcoxon signed-rank test result (p < 0.05). Overall, our findings indicate that the tactile feedback improves the immediate pain intensity through rehabilitation using our virtual reality system.

  17. Vibration-enhanced posture stabilization achieved by tactile supplementation: may blind individuals get extra benefits?

    PubMed

    Magalhães, Fernando Henrique; Kohn, André Fabio

    2011-08-01

    Diminished balance ability poses a serious health risk due to the increased likelihood of falling, and impaired postural stability is significantly associated with blindness and poor vision. Noise stimulation (by improving the detection of sub-threshold somatosensory information) and tactile supplementation (i.e., additional haptic information provided by an external contact surface) have been shown to improve the performance of the postural control system. Moreover, vibratory noise added to the source of tactile supplementation (e.g., applied to a surface that the fingertip touches) has been shown to enhance balance stability more effectively than tactile supplementation alone. In view of the above findings, in addition to the well established consensus that blind subjects show superior abilities in the use of tactile information, we hypothesized that blind subjects may take extra benefits from the vibratory noise added to the tactile supplementation and hence show greater improvements in postural stability than those observed for sighted subjects. If confirmed, this hypothesis may lay the foundation for the development of noise-based assistive devices (e.g., canes, walking sticks) for improving somatosensation and hence prevent falls in blind individuals. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. An Examination of the Potential for Blissymbolics to Serve as the Foundation for a Tactile Symbol System

    ERIC Educational Resources Information Center

    Isaacson, Mickey

    2012-01-01

    The primary purpose of this study was to determine whether Blissymbolics have the potential for being developed into a tactile symbol communication system. Tactile techniques are used by many individuals with augmentative and alternative communication (AAC) needs. Tactile processing is optimized by the use of minimalistic stimuli, i.e., stimuli…

  19. Visual and tactile interfaces for bi-directional human robot communication

    NASA Astrophysics Data System (ADS)

    Barber, Daniel; Lackey, Stephanie; Reinerman-Jones, Lauren; Hudson, Irwin

    2013-05-01

    Seamless integration of unmanned and systems and Soldiers in the operational environment requires robust communication capabilities. Multi-Modal Communication (MMC) facilitates achieving this goal due to redundancy and levels of communication superior to single mode interaction using auditory, visual, and tactile modalities. Visual signaling using arm and hand gestures is a natural method of communication between people. Visual signals standardized within the U.S. Army Field Manual and in use by Soldiers provide a foundation for developing gestures for human to robot communication. Emerging technologies using Inertial Measurement Units (IMU) enable classification of arm and hand gestures for communication with a robot without the requirement of line-of-sight needed by computer vision techniques. These devices improve the robustness of interpreting gestures in noisy environments and are capable of classifying signals relevant to operational tasks. Closing the communication loop between Soldiers and robots necessitates them having the ability to return equivalent messages. Existing visual signals from robots to humans typically require highly anthropomorphic features not present on military vehicles. Tactile displays tap into an unused modality for robot to human communication. Typically used for hands-free navigation and cueing, existing tactile display technologies are used to deliver equivalent visual signals from the U.S. Army Field Manual. This paper describes ongoing research to collaboratively develop tactile communication methods with Soldiers, measure classification accuracy of visual signal interfaces, and provides an integration example including two robotic platforms.

  20. Weber's Illusion and Body Shape: Anisotropy of Tactile Size Perception on the Hand

    ERIC Educational Resources Information Center

    Longo, Matthew R.; Haggard, Patrick

    2011-01-01

    The perceived distance between touches on a single skin surface is larger on regions of high tactile sensitivity than those with lower acuity, an effect known as "Weber's illusion". This illusion suggests that tactile size perception involves a representation of the perceived size of body parts preserving characteristics of the somatosensory…

  1. Inhibition drives configural superiority of illusory Gestalt: Combined behavioral and drift-diffusion model evidence.

    PubMed

    Nie, Qi-Yang; Maurer, Mara; Müller, Hermann J; Conci, Markus

    2016-05-01

    Illusory Kanizsa figures demonstrate that a perceptually completed whole is more than the sum of its composite parts. In the current study, we explored part/whole relationships in object completion using the configural superiority effect (CSE) with illusory figures (Pomerantz & Portillo, 2011). In particular, we investigated to which extent the CSE is modulated by closure in target and distractor configurations. Our results demonstrated a typical CSE, with detection of a configural whole being more efficient than the detection of a corresponding part-level target. Moreover, the CSE was more pronounced when grouped objects were presented in distractors rather than in the target. A follow-up experiment systematically manipulated closure in whole target or, respectively, distractor configurations. The results revealed the effect of closure to be again stronger in distractor, rather than in target configurations, suggesting that closure primarily affects the inhibition of distractors, and to a lesser extent the selection of the target. In addition, a drift-diffusion model analysis of our data revealed that efficient distractor inhibition expedites the rate of evidence accumulation, with closure in distractors particularly speeding the drift toward the decision boundary. In sum, our findings demonstrate that the CSE in Kanizsa figures derives primarily from the inhibition of closed distractor objects, rather than being driven by a conspicuous target configuration. Altogether, these results support a fundamental role of inhibition in driving configural superiority effects in visual search. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Development of CMOS MEMS inductive type tactile sensor with the integration of chrome steel ball force interface

    NASA Astrophysics Data System (ADS)

    Yeh, Sheng-Kai; Chang, Heng-Chung; Fang, Weileun

    2018-04-01

    This study presents an inductive tactile sensor with a chrome steel ball sensing interface based on the commercially available standard complementary metal-oxide-semiconductor (CMOS) process (the TSMC 0.18 µm 1P6M CMOS process). The tactile senor has a deformable polymer layer as the spring of the device and no fragile suspended thin film structures are required. As a tactile force is applied on the chrome steel ball, the polymer would deform. The distance between the chrome steel ball and the sensing coil would changed. Thus, the tactile force can be detected by the inductance change of the sensing coil. In short, the chrome steel ball acts as a tactile bump as well as the sensing interface. Experimental results show that the proposed inductive tactile sensor has a sensing range of 0-1.4 N with a sensitivity of 9.22(%/N) and nonlinearity of 2%. Preliminary wireless sensing test is also demonstrated. Moreover, the influence of the process and material issues on the sensor performances have also been investigated.

  3. Attention to sound improves auditory reliability in audio-tactile spatial optimal integration.

    PubMed

    Vercillo, Tiziana; Gori, Monica

    2015-01-01

    The role of attention on multisensory processing is still poorly understood. In particular, it is unclear whether directing attention toward a sensory cue dynamically reweights cue reliability during integration of multiple sensory signals. In this study, we investigated the impact of attention in combining audio-tactile signals in an optimal fashion. We used the Maximum Likelihood Estimation (MLE) model to predict audio-tactile spatial localization on the body surface. We developed a new audio-tactile device composed by several small units, each one consisting of a speaker and a tactile vibrator independently controllable by external software. We tested participants in an attentional and a non-attentional condition. In the attentional experiment, participants performed a dual task paradigm: they were required to evaluate the duration of a sound while performing an audio-tactile spatial task. Three unisensory or multisensory stimuli, conflictual or not conflictual sounds and vibrations arranged along the horizontal axis, were presented sequentially. In the primary task participants had to evaluate in a space bisection task the position of the second stimulus (the probe) with respect to the others (the standards). In the secondary task they had to report occasionally changes in duration of the second auditory stimulus. In the non-attentional task participants had only to perform the primary task (space bisection). Our results showed an enhanced auditory precision (and auditory weights) in the auditory attentional condition with respect to the control non-attentional condition. The results of this study support the idea that modality-specific attention modulates multisensory integration.

  4. The Invisible Universe: A Tactile and Braille Exhibit of Astronomical Images

    NASA Astrophysics Data System (ADS)

    Arcand, Kimberly; Lestition, K.; Watzke, M.; Steel, S.

    2010-01-01

    As part of the "From Earth to the Universe" (FETTU) project, a NASA-funded tactile exhibit for the visually impaired community was launched in July 2009 at the Martin Luther King Library in D.C. The exhibit is part of the global FETTU exhibit, a project of the International Year of Astronomy 2009. The science content of the exhibit includes explanations of our Sun, Eta Carinae, Crab Nebula, Whirlpool Galaxy, and the electromagnetic spectrum, and was adapted from the NASA-funded Braille/tactile book Touch the Invisible Sky. Multiple geographic locations and venue types have been targeted for the displays. The FETTU-tactile exhibit opens a wider door to experiencing and understanding astronomy, bridging a gap in learning. This exhibit is based upon work supported by the National Aeronautics and Space Administration under proposal 08-EPO08-0068 issued through the Science Mission Directorate.

  5. Adapted physical activity programme and self-perception in obese adolescents with intellectual disability: between morphological awareness and positive illusory bias.

    PubMed

    Salaun, Laureline; Reynes, Eric; Berthouze-Aranda, Sophie E

    2014-03-01

    In adolescent with intellectual disability, the management of obesity is a crucial issue, yet also quite complex because of their particular perception of themselves. This study investigated the relationship between self-perception variables and morphological variables and their changes after a 9-month Adapted Physical Activity (APA) programme. Twenty-three adolescents with intellectual disability responded to an adapted questionnaire, including the PSI-VSF-ID and a nine-drawing body silhouette scale. Anthropometric and body composition indicators were measured before and after the APA programme. The main predictor of the adolescents' self-perceptions was the inclination towards positive illusory bias before the intervention; obesity awareness ranked second. Morphological measurements did not contribute in the same way to self-perceptions in the initial and final data. This study confirms the interest of weight management programmes for adolescents with intellectual disability and points to the need to take positive illusory bias more fully into account in the study of self-perception. © 2013 John Wiley & Sons Ltd.

  6. Cross-modal tactile-taste interactions in food evaluations

    PubMed Central

    Slocombe, B. G.; Carmichael, D.A.; Simner, J.

    2016-01-01

    Detecting the taste components within a flavoured substance relies on exposing chemoreceptors within the mouth to the chemical components of ingested food. In our paper, we show that the evaluation of taste components can also be influenced by the tactile quality of the food. We first discuss how multisensory factors might influence taste, flavour and smell for both typical and atypical (synaesthetic) populations and we then present two empirical studies showing tactile-taste interactions in the general population. We asked a group of average adults to evaluate the taste components of flavoured food substances, whilst we presented simultaneous cross-sensory visuo-tactile cues within the eating environment. Specifically, we presented foodstuffs between subjects that were otherwise identical but had a rough versus smooth surface, or were served on a rough versus smooth serving-plate. We found no effect of the serving-plate, but we found the rough/smoothness of the foodstuff itself significantly influenced perception: food was rated as significantly more sour if it had a rough (vs. smooth) surface. In modifying taste perception via ostensibly unrelated dimensions, we demonstrate that the detection of tastes within flavours may be influenced by higher level cross-sensory cues. Finally, we suggest that the direction of our cross-sensory associations may speak to the types of hedonic mapping found both in normal multisensory integration, and in the unusual condition of synaesthesia. PMID:26169315

  7. A new tactile gnosis instrument in sensibility testing.

    PubMed

    Rosén, B; Lundborg, G

    1998-01-01

    A new quantitative test instrument for the assessment of tactile gnosis--the ability to identify shapes and textures without vision--is introduced. Introductory investigations of validity and reliability are presented. Fifty-four patients (60 hands) with carpal tunnel syndrome, vibration-induced neuropathy, or nerve repair at distal forearm level, and a matched asymptomatic control group were initially examined. After establishing the cut-off limit for normal tactile gnosis, sensitivity and specificity were calculated to determine the discriminative power of the new instrument. A high sensitivity (1.0) of the new shape/texture identification test was found in the group of patients with nerve repair. Given a cut-off limit, the sensitivity was lower in the groups with vibration-induced neuropathy and carpal tunnel syndrome (0.65 and 0.40, respectively), and the specificity of the test was 0.90 to 0.95. In a second step, a group of 52 patients who had had nerve repair at the distal forearm level were examined. Test-retest reliability was good, with a weighted kappa value of 0.79 to 0.81. Good reliability was also shown in the internal consistency of test items, with a Cronbach alpha value of 0.78. These introductory results indicate that the new shape/texture identification test can be useful in the assessment of tactile gnosis.

  8. Interaction of Perceptual Grouping and Crossmodal Temporal Capture in Tactile Apparent-Motion

    PubMed Central

    Chen, Lihan; Shi, Zhuanghua; Müller, Hermann J.

    2011-01-01

    Previous studies have shown that in tasks requiring participants to report the direction of apparent motion, task-irrelevant mono-beeps can “capture” visual motion perception when the beeps occur temporally close to the visual stimuli. However, the contributions of the relative timing of multimodal events and the event structure, modulating uni- and/or crossmodal perceptual grouping, remain unclear. To examine this question and extend the investigation to the tactile modality, the current experiments presented tactile two-tap apparent-motion streams, with an SOA of 400 ms between successive, left-/right-hand middle-finger taps, accompanied by task-irrelevant, non-spatial auditory stimuli. The streams were shown for 90 seconds, and participants' task was to continuously report the perceived (left- or rightward) direction of tactile motion. In Experiment 1, each tactile stimulus was paired with an auditory beep, though odd-numbered taps were paired with an asynchronous beep, with audiotactile SOAs ranging from −75 ms to 75 ms. Perceived direction of tactile motion varied systematically with audiotactile SOA, indicative of a temporal-capture effect. In Experiment 2, two audiotactile SOAs—one short (75 ms), one long (325 ms)—were compared. The long-SOA condition preserved the crossmodal event structure (so the temporal-capture dynamics should have been similar to that in Experiment 1), but both beeps now occurred temporally close to the taps on one side (even-numbered taps). The two SOAs were found to produce opposite modulations of apparent motion, indicative of an influence of crossmodal grouping. In Experiment 3, only odd-numbered, but not even-numbered, taps were paired with auditory beeps. This abolished the temporal-capture effect and, instead, a dominant percept of apparent motion from the audiotactile side to the tactile-only side was observed independently of the SOA variation. These findings suggest that asymmetric crossmodal grouping leads to an

  9. Tactile spatial resolution in blind braille readers.

    PubMed

    Van Boven, R W; Hamilton, R H; Kauffman, T; Keenan, J P; Pascual-Leone, A

    2000-06-27

    To determine if blind people have heightened tactile spatial acuity. Recently, studies using magnetic source imaging and somatosensory evoked potentials have shown that the cortical representation of the reading fingers of blind Braille readers is expanded compared to that of fingers of sighted subjects. Furthermore, the visual cortex is activated during certain tactile tasks in blind subjects but not sighted subjects. The authors hypothesized that the expanded cortical representation of fingers used in Braille reading may reflect an enhanced fidelity in the neural transmission of spatial details of a stimulus. If so, the quantitative limit of spatial acuity would be superior in blind people. The authors employed a grating orientation discrimination task in which threshold performance is accounted for by the spatial resolution limits of the neural image evoked by a stimulus. The authors quantified the psychophysical limits of spatial acuity at the middle and index fingers of 15 blind Braille readers and 15 sighted control subjects. The mean grating orientation threshold was significantly (p = 0.03) lower in the blind group (1.04 mm) compared to the sighted group (1.46 mm). The self-reported dominant reading finger in blind subjects had a mean grating orientation threshold of 0.80 mm, which was significantly better than other fingers tested. Thresholds at non-Braille reading fingers in blind subjects averaged 1.12 mm, which were also superior to sighted subjects' performances. Superior tactile spatial acuity in blind Braille readers may represent an adaptive, behavioral correlate of cortical plasticity.

  10. Motor adaptation to Coriolis force perturbations of reaching movements: endpoint but not trajectory adaptation transfers to the nonexposed arm

    NASA Technical Reports Server (NTRS)

    Dizio, P.; Lackner, J. R.

    1995-01-01

    1. Reaching movements made in a rotating room generate Coriolis forces that are directly proportional to the cross product of the room's angular velocity and the arm's linear velocity. Such Coriolis forces are inertial forces not involving mechanical contact with the arm. 2. We measured the trajectories of arm movements made in darkness to a visual target that was extinguished at the onset of each reach. Prerotation subjects pointed with both the right and left arms in alternating sets of eight movements. During rotation at 10 rpm, the subjects reached only with the right arm. Postrotation, the subjects pointed with the left and right arms, starting with the left, in alternating sets of eight movements. 3. The initial perrotary reaching movements of the right arm were highly deviated both in movement path and endpoint relative to the prerotation reaches of the right arm. With additional movements, subjects rapidly regained straight movement paths and accurate endpoints despite the absence of visual or tactile feedback about reaching accuracy. The initial postrotation reaches of the left arm followed straight paths to the wrong endpoint. The initial postrotation reaches of the right arm had paths with mirror image curvature to the initial perrotation reaches of the right arm but went to the correct endpoint. 4. These observations are inconsistent with current equilibrium point models of movement control. Such theories predict accurate reaches under our experimental conditions. Our observations further show independent implementation of movement and posture, as evidenced by transfer of endpoint adaptation to the nonexposed arm without transfer of path adaptation. Endpoint control may occur at a relatively central stage that represents general constraints such as gravitoinertial force background or egocentric direction relative to both arms, and control of path may occur at a more peripheral stage that represents moments of inertia and muscle dynamics unique to each

  11. Anticipation increases tactile stimulus processing in the ipsilateral primary somatosensory cortex.

    PubMed

    van Ede, Freek; de Lange, Floris P; Maris, Eric

    2014-10-01

    Stimulus anticipation improves perception. To account for this improvement, we investigated how stimulus processing is altered by anticipation. In contrast to a large body of previous work, we employed a demanding perceptual task and investigated sensory responses that occur beyond early evoked activity in contralateral primary sensory areas: Stimulus-induced modulations of neural oscillations. For this, we recorded magnetoencephalography in 19 humans while they performed a cued tactile identification task involving the identification of either a proximal or a distal stimulation on the fingertips. We varied the cue-target interval between 0 and 1000 ms such that tactile targets occurred at various degrees of anticipation. This allowed us to investigate the influence of anticipation on stimulus processing in a parametric fashion. We observed that anticipation increases the stimulus-induced response (suppression of beta-band oscillations) originating from the ipsilateral primary somatosensory cortex. This occurs in the period in which the tactile memory trace is analyzed and is correlated with the anticipation-induced improvement in tactile perception. We propose that this ipsilateral response indicates distributed processing across bilateral primary sensory cortices, of which the extent increases with anticipation. This constitutes a new and potentially important mechanism contributing to perception and its improvement following anticipation. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Compact Tactile Sensors for Robot Fingers

    NASA Technical Reports Server (NTRS)

    Martin, Toby B.; Lussy, David; Gaudiano, Frank; Hulse, Aaron; Diftler, Myron A.; Rodriguez, Dagoberto; Bielski, Paul; Butzer, Melisa

    2004-01-01

    Compact transducer arrays that measure spatial distributions of force or pressure have been demonstrated as prototypes of tactile sensors to be mounted on fingers and palms of dexterous robot hands. The pressure- or force-distribution feedback provided by these sensors is essential for the further development and implementation of robot-control capabilities for humanlike grasping and manipulation.

  13. Hearing shapes our perception of time: temporal discrimination of tactile stimuli in deaf people.

    PubMed

    Bolognini, Nadia; Cecchetto, Carlo; Geraci, Carlo; Maravita, Angelo; Pascual-Leone, Alvaro; Papagno, Costanza

    2012-02-01

    Confronted with the loss of one type of sensory input, we compensate using information conveyed by other senses. However, losing one type of sensory information at specific developmental times may lead to deficits across all sensory modalities. We addressed the effect of auditory deprivation on the development of tactile abilities, taking into account changes occurring at the behavioral and cortical level. Congenitally deaf and hearing individuals performed two tactile tasks, the first requiring the discrimination of the temporal duration of touches and the second requiring the discrimination of their spatial length. Compared with hearing individuals, deaf individuals were impaired only in tactile temporal processing. To explore the neural substrate of this difference, we ran a TMS experiment. In deaf individuals, the auditory association cortex was involved in temporal and spatial tactile processing, with the same chronometry as the primary somatosensory cortex. In hearing participants, the involvement of auditory association cortex occurred at a later stage and selectively for temporal discrimination. The different chronometry in the recruitment of the auditory cortex in deaf individuals correlated with the tactile temporal impairment. Thus, early hearing experience seems to be crucial to develop an efficient temporal processing across modalities, suggesting that plasticity does not necessarily result in behavioral compensation.

  14. The Relationship between Gentle Tactile Stimulation on the Fetus and Its Temperament 3 Months after Birth

    PubMed Central

    Wang, Zhe-Wei; Hua, Jing; Xu, Yu-Hong

    2015-01-01

    Objective. The aim of this study was to evaluate the effect of gentle tactile stimulation on the fetus in its temperament 3 months after birth. Method. A total of 302 mother-3-month-infant dyads enrolled the retrospective cohort study. 76 mothers had regular gentle tactile stimulation on the fetus in their pregnancy; 62 mothers had irregular tactile stimulation on the fetus, and the rest of 164 mothers who had no tactile stimulation served as nonexposure group. Temperament was assessed using the EITS (a nine-dimensional scale of temperament). Results. Significant difference in temperament type was found among infants in 3 groups at 3 months of age. In the regular practice group, the babies with easy type temperament accounted for 73.7%, which was higher than that in irregular practice group (53.2%, P = 0.012) and that in the control group (42.1%, P < 0.001). Compared to infants in no practice group, the infants who had received regular gentle tactile stimulation before birth were lower in negative mood (P = 0.047) while higher in adaptability (P < 0.001), approach (P = 0.001), and persistence (P = 0.001), respectively. Conclusion. Regular gentle tactile stimulation on fetus may promote the formation of easy type infant temperament. PMID:26180374

  15. Illusory Memories of Emotionally Charged Words in Autism Spectrum Disorder: Further Evidence for Atypical Emotion Processing outside the Social Domain

    ERIC Educational Resources Information Center

    Gaigg, Sebastian B.; Bowler, Dermot M.

    2009-01-01

    Recent evidence suggests that individuals with ASD may not accumulate distinct representations of emotional information throughout development. On the basis of this observation we predicted that such individuals would not be any less likely to falsely remember emotionally significant as compared to neutral words when such "illusory memories" are…

  16. High-Accuracy Readout Electronics for Piezoresistive Tactile Sensors

    PubMed Central

    Vidal-Verdú, Fernando

    2017-01-01

    The typical layout in a piezoresistive tactile sensor arranges individual sensors to form an array with M rows and N columns. While this layout reduces the wiring involved, it does not allow the values of the sensor resistors to be measured individually due to the appearance of crosstalk caused by the nonidealities of the array reading circuits. In this paper, two reading methods that minimize errors resulting from this phenomenon are assessed by designing an electronic system for array reading, and the results are compared to those obtained using the traditional method, obviating the nonidealities of the reading circuit. The different models were compared by testing the system with an array of discrete resistors. The system was later connected to a tactile sensor with 8 × 7 taxels. PMID:29104229

  17. 3D capacitive tactile sensor using DRIE micromachining

    NASA Astrophysics Data System (ADS)

    Chuang, Chiehtang; Chen, Rongshun

    2005-07-01

    This paper presents a three dimensional micro capacitive tactile sensor that can detect normal and shear forces which is fabricated using deep reactive ion etching (DRIE) bulk silicon micromachining. The tactile sensor consists of a force transmission plate, a symmetric suspension system, and comb electrodes. The sensing character is based on the changes of capacitance between coplanar sense electrodes. High sensitivity is achieved by using the high aspect ratio interdigital electrodes with narrow comb gaps and large overlap areas. The symmetric suspension mechanism of this sensor can easily solve the coupling problem of measurement and increase the stability of the structure. In this paper, the sensor structure is designed, the capacitance variation of the proposed device is theoretically analyzed, and the finite element analysis of mechanical behavior of the structures is performed.

  18. The interaction between felt touch and tactile consequences of observed actions: an action-based somatosensory congruency paradigm.

    PubMed

    Deschrijver, Eliane; Wiersema, Jan R; Brass, Marcel

    2016-07-01

    Action observation leads to a representation of both the motor aspect of an observed action (motor simulation) and its somatosensory consequences (action-based somatosensory simulation) in the observer's brain. In the current electroencephalography-study, we investigated the neuronal interplay of action-based somatosensory simulation and felt touch. We presented index or middle finger tapping movements of a human or a wooden hand, while simultaneously presenting 'tap-like' tactile sensations to either the corresponding or non-corresponding fingertip of the participant. We focused on an early stage of somatosensory processing [P50, N100 and N140 sensory evoked potentials (SEPs)] and on a later stage of higher-order processing (P3-complex). The results revealed an interaction effect of animacy and congruency in the early P50 SEP and an animacy effect in the N100/N140 SEPs. In the P3-complex, we found an interaction effect indicating that the influence of congruency was larger in the human than in the wooden hand. We argue that the P3-complex may reflect higher-order self-other distinction by signaling simulated action-based touch that does not match own tactile information. As such, the action-based somatosensory congruency paradigm might help understand higher-order social processes from a somatosensory point of view. © The Author (2015). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  19. Short-term memory for spatial configurations in the tactile modality: a comparison with vision.

    PubMed

    Picard, Delphine; Monnier, Catherine

    2009-11-01

    This study investigates the role of acquisition constraints on the short-term retention of spatial configurations in the tactile modality in comparison with vision. It tests whether the sequential processing of information inherent to the tactile modality could account for limitation in short-term memory span for tactual-spatial information. In addition, this study investigates developmental aspects of short-term memory for tactual- and visual-spatial configurations. A total of 144 child and adult participants were assessed for their memory span in three different conditions: tactual, visual, and visual with a limited field of view. The results showed lower tactual-spatial memory span than visual-spatial, regardless of age. However, differences in memory span observed between the tactile and visual modalities vanished when the visual processing of information occurred within a limited field. These results provide evidence for an impact of acquisition constraints on the retention of spatial information in the tactile modality in both childhood and adulthood.

  20. Stereo camera based virtual cane system with identifiable distance tactile feedback for the blind.

    PubMed

    Kim, Donghun; Kim, Kwangtaek; Lee, Sangyoun

    2014-06-13

    In this paper, we propose a new haptic-assisted virtual cane system operated by a simple finger pointing gesture. The system is developed by two stages: development of visual information delivery assistant (VIDA) with a stereo camera and adding a tactile feedback interface with dual actuators for guidance and distance feedbacks. In the first stage, user's pointing finger is automatically detected using color and disparity data from stereo images and then a 3D pointing direction of the finger is estimated with its geometric and textural features. Finally, any object within the estimated pointing trajectory in 3D space is detected and the distance is then estimated in real time. For the second stage, identifiable tactile signals are designed through a series of identification experiments, and an identifiable tactile feedback interface is developed and integrated into the VIDA system. Our approach differs in that navigation guidance is provided by a simple finger pointing gesture and tactile distance feedbacks are perfectly identifiable to the blind.

  1. Stereo Camera Based Virtual Cane System with Identifiable Distance Tactile Feedback for the Blind

    PubMed Central

    Kim, Donghun; Kim, Kwangtaek; Lee, Sangyoun

    2014-01-01

    In this paper, we propose a new haptic-assisted virtual cane system operated by a simple finger pointing gesture. The system is developed by two stages: development of visual information delivery assistant (VIDA) with a stereo camera and adding a tactile feedback interface with dual actuators for guidance and distance feedbacks. In the first stage, user's pointing finger is automatically detected using color and disparity data from stereo images and then a 3D pointing direction of the finger is estimated with its geometric and textural features. Finally, any object within the estimated pointing trajectory in 3D space is detected and the distance is then estimated in real time. For the second stage, identifiable tactile signals are designed through a series of identification experiments, and an identifiable tactile feedback interface is developed and integrated into the VIDA system. Our approach differs in that navigation guidance is provided by a simple finger pointing gesture and tactile distance feedbacks are perfectly identifiable to the blind. PMID:24932864

  2. A dense array stimulator to generate arbitrary spatio-temporal tactile stimuli

    PubMed Central

    Killebrew, Justin H.; Bensmaïa, Sliman J.; Dammann, John F.; Denchev, Peter; Hsiao, Steven S.; Craig, James C.

    2007-01-01

    The generation and presentation of tactile stimuli presents a unique challenge. Unlike vision and audition, in which standard equipment such as monitors and audio systems can be used for most experiments, tactile stimuli and/or stimulators often have to be tailor-made for a given study. Here, we present a novel tactile stimulator designed to present arbitrary spatio-temporal stimuli to the skin. The stimulator consists of 400 pins, arrayed over a 1 cm2 area, each under independent computer control. The dense array allows for an unprecedented number of stimuli to be presented within an experimental session (e.g., up to 1200 stimuli per minute) and for stimuli to be generated adaptively. The stimulator can be used in a variety of modes and can deliver indented and scanned patterns as well as stimuli defined by mathematical spatio-temporal functions (e.g., drifting sinusoids). We describe the hardware and software of the system, and discuss previous and prospective applications. PMID:17134760

  3. Tactile perception of skin and skin cream by friction induced vibrations.

    PubMed

    Ding, Shuyang; Bhushan, Bharat

    2016-11-01

    Skin cream smooths, softens, and moistens skin by altering surface roughness and tribological properties of skin. Sliding generates vibrations that activate mechanoreceptors located in skin. The brain interprets tactile information to identify skin feel. Understanding the tactile sensing mechanisms of skin with and without cream treatment is important to numerous applications including cosmetics, textiles, and robotics sensors. In this study, frequency spectra of friction force and friction induced vibration signals were carried out to investigate tactile perception by an artificial finger sliding on skin. The influence of normal load, velocity, and cream treatment time were studied. Coherence between friction force and vibration signals were found. The amplitude of vibration decreased after cream treatment, leading to smoother perception. Increasing normal load or velocity between contacting surfaces generated a smoother perception with cream treatment, but rougher perception without treatment. As cream treatment time increases, skin becomes smoother. The related mechanisms are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Sensing Senses: Tactile Feedback for the Prevention of Decubitus Ulcers

    PubMed Central

    Verbunt, Marcel

    2009-01-01

    Decubitus ulcers, also known as pressure sores, is a major problem in health care, in particular for patients with spinal cord injuries. These patients cannot feel the discomfort that would urge healthy people to change their posture. We describe a system that uses a sensor mat to detect problematic postures and provides tactile feedback to the user. The results of our preliminary study with healthy subjects show that the tactile feedback is a viable option to spoken feedback. We envision the system being used for rehabilitation games, but also for everyday Decubitus ulcers prevention. PMID:19949852

  5. The effects of negative emotions on sensory perception: fear but not anger decreases tactile sensitivity

    PubMed Central

    Kelley, Nicholas J.; Schmeichel, Brandon J.

    2014-01-01

    Emotions and sensory perceptions are closely intertwined. Of the five senses, sight has been by far the most extensively studied sense in emotion research. Relatively less is known about how emotions influence the other four senses. Touch is essential for nonverbal communication in both humans and other animals. The current investigation tested competing hypotheses about the effect of fear on tactile perception. One hypothesis based on evolutionary considerations predicts that fear enhances sensory perception, including tactile sensitivity. A competing hypothesis based on research on peripheral psychophysiology predicts that fear should decrease tactile sensitivity. Two experiments that induced negative emotional states and measured two-point discrimination ability at the fingertip found that fear reduces tactile sensitivity relative to anger or a neutral control condition (Studies 1 and 2). These findings did not appear to be driven by participants’ naïve beliefs about the influence of emotions on touch (Study 3). The results represent the first evidence of the causal impact of emotional states on tactile sensitivity, are consistent with prior evidence for the peripheral physiological effects of fear, and offer novel empirical grounds for developing and advancing theories of emotional influences on sensory perception. PMID:25202299

  6. The effects of negative emotions on sensory perception: fear but not anger decreases tactile sensitivity.

    PubMed

    Kelley, Nicholas J; Schmeichel, Brandon J

    2014-01-01

    Emotions and sensory perceptions are closely intertwined. Of the five senses, sight has been by far the most extensively studied sense in emotion research. Relatively less is known about how emotions influence the other four senses. Touch is essential for nonverbal communication in both humans and other animals. The current investigation tested competing hypotheses about the effect of fear on tactile perception. One hypothesis based on evolutionary considerations predicts that fear enhances sensory perception, including tactile sensitivity. A competing hypothesis based on research on peripheral psychophysiology predicts that fear should decrease tactile sensitivity. Two experiments that induced negative emotional states and measured two-point discrimination ability at the fingertip found that fear reduces tactile sensitivity relative to anger or a neutral control condition (Studies 1 and 2). These findings did not appear to be driven by participants' naïve beliefs about the influence of emotions on touch (Study 3). The results represent the first evidence of the causal impact of emotional states on tactile sensitivity, are consistent with prior evidence for the peripheral physiological effects of fear, and offer novel empirical grounds for developing and advancing theories of emotional influences on sensory perception.

  7. Tactile Object Familiarity in the Blind Brain Reveals the Supramodal Perceptual-Mnemonic Nature of the Perirhinal Cortex

    PubMed Central

    Cacciamani, Laura; Likova, Lora T.

    2016-01-01

    This study is the first to investigate the neural underpinnings of tactile object familiarity in the blind during both perception and memory. In the sighted, the perirhinal cortex (PRC) has been implicated in the assessment of visual object familiarity—a crucial everyday task—as evidenced by reduced activation when an object becomes familiar. Here, to examine the PRC’s role in tactile object familiarity in the absence of vision, we trained blind participants on a unique memory-guided drawing technique and measured brain activity while they perceptually explored raised-line drawings, drew them from tactile memory, and scribbled (control). Functional magnetic resonance imaging (fMRI) before and after a week of training revealed a significant decrease in PRC activation from pre- to post-training (i.e., from unfamiliar to familiar) during perceptual exploration as well as memory-guided drawing, but not scribbling. This familiarity-based reduction is the first evidence that the PRC represents tactile object familiarity in the blind. Furthermore, the finding of this effect during both tactile perception and tactile memory provides the critical link in establishing the PRC as a structure whose representations are supramodal for both perception and memory. PMID:27148002

  8. Fully printed flexible fingerprint-like three-axis tactile and slip force and temperature sensors for artificial skin.

    PubMed

    Harada, Shingo; Kanao, Kenichiro; Yamamoto, Yuki; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu

    2014-12-23

    A three-axis tactile force sensor that determines the touch and slip/friction force may advance artificial skin and robotic applications by fully imitating human skin. The ability to detect slip/friction and tactile forces simultaneously allows unknown objects to be held in robotic applications. However, the functionalities of flexible devices have been limited to a tactile force in one direction due to difficulties fabricating devices on flexible substrates. Here we demonstrate a fully printed fingerprint-like three-axis tactile force and temperature sensor for artificial skin applications. To achieve economic macroscale devices, these sensors are fabricated and integrated using only printing methods. Strain engineering enables the strain distribution to be detected upon applying a slip/friction force. By reading the strain difference at four integrated force sensors for a pixel, both the tactile and slip/friction forces can be analyzed simultaneously. As a proof of concept, the high sensitivity and selectivity for both force and temperature are demonstrated using a 3×3 array artificial skin that senses tactile, slip/friction, and temperature. Multifunctional sensing components for a flexible device are important advances for both practical applications and basic research in flexible electronics.

  9. Feeling small: exploring the tactile perception limits.

    PubMed

    Skedung, Lisa; Arvidsson, Martin; Chung, Jun Young; Stafford, Christopher M; Berglund, Birgitta; Rutland, Mark W

    2013-01-01

    The human finger is exquisitely sensitive in perceiving different materials, but the question remains as to what length scales are capable of being distinguished in active touch. We combine material science with psychophysics to manufacture and haptically explore a series of topographically patterned surfaces of controlled wavelength, but identical chemistry. Strain-induced surface wrinkling and subsequent templating produced 16 surfaces with wrinkle wavelengths ranging from 300 nm to 90 μm and amplitudes between 7 nm and 4.5 μm. Perceived similarities of these surfaces (and two blanks) were pairwise scaled by participants, and interdistances among all stimuli were determined by individual differences scaling (INDSCAL). The tactile space thus generated and its two perceptual dimensions were directly linked to surface physical properties - the finger friction coefficient and the wrinkle wavelength. Finally, the lowest amplitude of the wrinkles so distinguished was approximately 10 nm, demonstrating that human tactile discrimination extends to the nanoscale.

  10. Predicting successful tactile mapping of virtual objects.

    PubMed

    Brayda, Luca; Campus, Claudio; Gori, Monica

    2013-01-01

    Improving spatial ability of blind and visually impaired people is the main target of orientation and mobility (O&M) programs. In this study, we use a minimalistic mouse-shaped haptic device to show a new approach aimed at evaluating devices providing tactile representations of virtual objects. We consider psychophysical, behavioral, and subjective parameters to clarify under which circumstances mental representations of spaces (cognitive maps) can be efficiently constructed with touch by blindfolded sighted subjects. We study two complementary processes that determine map construction: low-level perception (in a passive stimulation task) and high-level information integration (in an active exploration task). We show that jointly considering a behavioral measure of information acquisition and a subjective measure of cognitive load can give an accurate prediction and a practical interpretation of mapping performance. Our simple TActile MOuse (TAMO) uses haptics to assess spatial ability: this may help individuals who are blind or visually impaired to be better evaluated by O&M practitioners or to evaluate their own performance.

  11. The outcome of tactile touch on stress parameters in intensive care: a randomized controlled trial.

    PubMed

    Henricson, Maria; Ersson, Anders; Määttä, Sylvia; Segesten, Kerstin; Berglund, Anna-Lena

    2008-11-01

    The study aimed to investigate the effects of a five-day tactile touch intervention in order to find new and unconventional measures to moderate the detrimental influence of patients' stressors during intensive care. The hypothesis was that tactile touch would decrease stress indicators such as anxiety, glucose metabolism, blood pressure, heart rate and requirements of sedative drugs and noradrenalin. A randomized controlled trial was undertaken with 44 patients, which were assigned either to tactile touch or standard treatment (a rest hour). Observations of the stress indicators were made before, during and after the intervention or standard treatment. The study showed that tactile touch led to significantly lower levels of anxiety. The circulatory parameters suggested increased circulatory stability indicated by a reduction in noradrenalin requirement. The results need to be further validated through studies with larger sample sizes.

  12. Investigation of the piezoelectric thimble tactile device operating modes.

    PubMed

    Bansevicius, Ramutis; Dragasius, Egidijus; Grigas, Vytautas; Jurenas, Vytautas; Mazeika, Darius; Zvironas, Arunas

    2014-01-01

    A multifunctional device to transfer graphical or text information for blind or visually impaired is presented. The prototype using tactile perception has been designed where information displayed on the screen of electronic device (mobile phone, PC) is transferred by oscillating needle, touching the fingertip. Having the aim to define optimal parameters of the fingertip excitation by needle, the computational analysis of different excitation modes has been carried out. A 3D solid computational finite element model of the skin segment, comprising four main fingertip skin layers (stratum corneum, epidermis, dermis and hypodermis) was built by using ANSYS Workbench FEA software. Harmonic analysis of its stress-strain state under excitation with different frequency (up to 10000 Hz) and harmonic force (0.01 N), acting outer stratum corneum layer in normal direction at one, two or three points has been performed. The influence of the mode of dynamic loading of skin was evaluated (in terms of the tactile signal level) on the basis of the normal and shear elastic strain in dermis, where mechanoreceptors are placed. It is shown that the tactile perception of information, delivered by three vibrating pins, may be influenced by configuration of excitation points (their number and phase of loading) and the frequency of excitation.

  13. Changes in passive tactile sensibility associated with dental implants following their placement.

    PubMed

    El-Sheikh, Ali M; Hobkirk, John A; Howell, Peter G T; Gilthorpe, Mark S

    2003-01-01

    This study investigated the changes that might occur in passive tactile sensibility during a period of 3 months following Implant placement in a group of edentulous subjects treated with dental implants. The effect of changing the velocity of force application on passive tactile sensibility was also investigated. Five edentulous subjects who had been treated (as a part of an immediate loading study) with 2 or more Nobel Biocare dental implants in the anterior mandible were studied. Pushing forces were applied directly and perpendicular to the long axes of the abutments until the subjects felt the first sensation of pressure, using a computer-controlled, custom-made device. The force was measured with an integral transducer. The applied force had a ramped staircase pattern, which was used at 2 different tip velocities. The measurements were taken on 4 occasions: 1, 2, 4, and 12 weeks after fitting the abutments. Statistical analysis, using multilevel modeling, demonstrated that there was a significant decrease In the tactile threshold over successive weeks following implant placement. It also demonstrated that high velocity exhibited a higher threshold than low velocity. It could be concluded that there was a significant increase In passive tactile sensibility during the healing phase following implant placement.

  14. A systematic approach to the Kansei factors of tactile sense regarding the surface roughness.

    PubMed

    Choi, Kyungmee; Jun, Changrim

    2007-01-01

    Designing products to satisfy customers' emotion requires the information gathered through the human senses, which are visual, auditory, olfactory, gustatory, or tactile senses. By controlling certain design factors, customers' emotion can be evaluated, designed, and satisfied. In this study, a systematic approach is proposed to study the tactile sense regarding the surface roughness. Numerous pairs of antonymous tactile adjectives are collected and clustered. The optimal number of adjective clusters is estimated based on the several criterion functions. The representative average preferences of the final clusters are obtained as the estimates of engineering parameters to control the surface roughness of the commercial polymer-based products.

  15. Seeing the Body Distorts Tactile Size Perception

    ERIC Educational Resources Information Center

    Longo, Matthew R.; Sadibolova, Renata

    2013-01-01

    Vision of the body modulates somatosensation, even when entirely non-informative about stimulation. For example, seeing the body increases tactile spatial acuity, but reduces acute pain. While previous results demonstrate that vision of the body modulates somatosensory sensitivity, it is unknown whether vision also affects metric properties of…

  16. Incrementally learning objects by touch: online discriminative and generative models for tactile-based recognition.

    PubMed

    Soh, Harold; Demiris, Yiannis

    2014-01-01

    Human beings not only possess the remarkable ability to distinguish objects through tactile feedback but are further able to improve upon recognition competence through experience. In this work, we explore tactile-based object recognition with learners capable of incremental learning. Using the sparse online infinite Echo-State Gaussian process (OIESGP), we propose and compare two novel discriminative and generative tactile learners that produce probability distributions over objects during object grasping/palpation. To enable iterative improvement, our online methods incorporate training samples as they become available. We also describe incremental unsupervised learning mechanisms, based on novelty scores and extreme value theory, when teacher labels are not available. We present experimental results for both supervised and unsupervised learning tasks using the iCub humanoid, with tactile sensors on its five-fingered anthropomorphic hand, and 10 different object classes. Our classifiers perform comparably to state-of-the-art methods (C4.5 and SVM classifiers) and findings indicate that tactile signals are highly relevant for making accurate object classifications. We also show that accurate "early" classifications are possible using only 20-30 percent of the grasp sequence. For unsupervised learning, our methods generate high quality clusterings relative to the widely-used sequential k-means and self-organising map (SOM), and we present analyses into the differences between the approaches.

  17. A Magnetoresistive Tactile Sensor for Harsh Environment Applications

    PubMed Central

    Alfadhel, Ahmed; Khan, Mohammed Asadullah; Cardoso, Susana; Leitao, Diana; Kosel, Jürgen

    2016-01-01

    A magnetoresistive tactile sensor is reported, which is capable of working in high temperatures up to 140 °C. Hair-like bioinspired structures, known as cilia, made out of permanent magnetic nanocomposite material on top of spin-valve giant magnetoresistive (GMR) sensors are used for tactile sensing at high temperatures. The magnetic nanocomposite, consisting of iron nanowires incorporated into the polymer polydimethylsiloxane (PDMS), is very flexible, biocompatible, has high remanence, and is also resilient to antagonistic sensing ambient. When the cilia come in contact with a surface, they deflect in compliance with the surface topology. This yields a change of the GMR sensor signal, enabling the detection of extremely fine features. The spin-valve is covered with a passivation layer, which enables adequate performance in spite of harsh environmental conditions, as demonstrated in this paper for high temperature. PMID:27164113

  18. Those are Your Legs: The Effect of Visuo-Spatial Viewpoint on Visuo-Tactile Integration and Body Ownership

    PubMed Central

    Pozeg, Polona; Galli, Giulia; Blanke, Olaf

    2015-01-01

    Experiencing a body part as one’s own, i.e., body ownership, depends on the integration of multisensory bodily signals (including visual, tactile, and proprioceptive information) with the visual top-down signals from peripersonal space. Although it has been shown that the visuo-spatial viewpoint from where the body is seen is an important visual top-down factor for body ownership, different studies have reported diverging results. Furthermore, the role of visuo-spatial viewpoint (sometime also called first-person perspective) has only been studied for hands or the whole body, but not for the lower limbs. We thus investigated whether and how leg visuo-tactile integration and leg ownership depended on the visuo-spatial viewpoint from which the legs were seen and the anatomical similarity of the visual leg stimuli. Using a virtual leg illusion, we tested the strength of visuo-tactile integration of leg stimuli using the crossmodal congruency effect (CCE) as well as the subjective sense of leg ownership (assessed by a questionnaire). Fifteen participants viewed virtual legs or non-corporeal control objects, presented either from their habitual first-person viewpoint or from a viewpoint that was rotated by 90°(third-person viewpoint), while applying visuo-tactile stroking between the participants legs and the virtual legs shown on a head-mounted display. The data show that the first-person visuo-spatial viewpoint significantly boosts the visuo-tactile integration as well as the sense of leg ownership. Moreover, the viewpoint-dependent increment of the visuo-tactile integration was only found in the conditions when participants viewed the virtual legs (absent for control objects). These results confirm the importance of first person visuo-spatial viewpoint for the integration of visuo-tactile stimuli and extend findings from the upper extremity and the trunk to visuo-tactile integration and ownership for the legs. PMID:26635663

  19. Studies on adaptation to complete dentures. Part II: Oral stereognosis and tactile sensibility.

    PubMed

    Müller, F; Link, I; Fuhr, K; Utz, K H

    1995-10-01

    High oral perception is thought to contribute to poor adaptation to new dentures. The aim of this study was to evaluate the oral stereognosis and tactile sensibility in edentate subjects and relate these to patient age and capability of adaptation to new prostheses. A total of 67 patients were provided with new complete dentures 2-3 weeks before the experiment. In 54 subjects, the oral stereognosis was evaluated by 12 different test-pieces, which were placed unseen on the tongue and had to be recognized. In 38 patients, the oral tactile sensibility was determined in the premolar area using copper foils. The capability of adaptation was evaluated by a questionnaire. Denture retention was assessed by clinical examination. The number of correctly identified test-pieces and the average identification time were related to the age, but no relation was found to patients' capability of adaptation. The tactile sensibility was found to be impaired with age and diminished capability of adaptation. Both adaptation and oral tactile sensibility were significantly lower in subjects with poor lower-denture retention. In conclusion, the results cannot support a relationship between high oral stereognosis and adaptation problems. However, good denture retention facilitates the adaptation process.

  20. Evaluation of magical thinking: validation of the Illusory Beliefs Inventory.

    PubMed

    Shihata, Sarah; Egan, Sarah J; Rees, Clare S

    2014-01-01

    Magical thinking has been related to obsessive-compulsive disorder; yet, little research has examined this construct in other anxiety disorders. The Illusory Beliefs Inventory (IBI) is a recently developed measure of magical thinking. The aim of this study was to investigate the psychometric properties of this new measure and to determine if magical thinking accounts for pathological worry beyond the well-researched constructs of intolerance of uncertainty (IU) and perfectionism. A sample of 502 participants completed an online survey. Confirmatory factor analysis identified a three-factor solution for the IBI, and the measure had good internal consistency (α = .92), test-retest reliability (r = .94) and discriminant validity. Magical thinking, IU, and perfectionism all predicted pathological worry; however, magical thinking accounted for less than 1% of unique variance in worry, suggesting that it is not strongly related to worry. Further investigation regarding the validity and clinical utility of the IBI is required.

  1. An Evaluation of Substrates for Tactile Maps and Diagrams: Scanning Speed and Users' Preferences

    ERIC Educational Resources Information Center

    Jehoel, Sandra; Ungar, Simon; McCallum, Don; Rowell, Jonathan

    2005-01-01

    This study evaluated the relative suitability of a range of base materials for producing tactile maps and diagrams via a new ink-jet process. The visually impaired and sighted participants tactilely scanned arrays of symbols that were printed on seven substrate materials, including paper, plastic, and aluminum. In general, the rougher substrates…

  2. Neurosurgical tactile discrimination training with haptic-based virtual reality simulation.

    PubMed

    Patel, Achal; Koshy, Nick; Ortega-Barnett, Juan; Chan, Hoi C; Kuo, Yong-Fan; Luciano, Cristian; Rizzi, Silvio; Matulyauskas, Martin; Kania, Patrick; Banerjee, Pat; Gasco, Jaime

    2014-12-01

    To determine if a computer-based simulation with haptic technology can help surgical trainees improve tactile discrimination using surgical instruments. Twenty junior medical students participated in the study and were randomized into two groups. Subjects in Group A participated in virtual simulation training using the ImmersiveTouch simulator (ImmersiveTouch, Inc., Chicago, IL, USA) that required differentiating the firmness of virtual spheres using tactile and kinesthetic sensation via haptic technology. Subjects in Group B did not undergo any training. With their visual fields obscured, subjects in both groups were then evaluated on their ability to use the suction and bipolar instruments to find six elastothane objects with areas ranging from 1.5 to 3.5 cm2 embedded in a urethane foam brain cavity model while relying on tactile and kinesthetic sensation only. A total of 73.3% of the subjects in Group A (simulation training) were able to find the brain cavity objects in comparison to 53.3% of the subjects in Group B (no training) (P  =  0.0183). There was a statistically significant difference in the total number of Group A subjects able to find smaller brain cavity objects (size ≤ 2.5 cm2) compared to that in Group B (72.5 vs. 40%, P  =  0.0032). On the other hand, no significant difference in the number of subjects able to detect larger objects (size ≧ 3 cm2) was found between Groups A and B (75 vs. 80%, P  =  0.7747). Virtual computer-based simulators with integrated haptic technology may improve tactile discrimination required for microsurgical technique.

  3. Illusory motion reveals velocity matching, not foveation, drives smooth pursuit of large objects

    PubMed Central

    Ma, Zheng; Watamaniuk, Scott N. J.; Heinen, Stephen J.

    2017-01-01

    When small objects move in a scene, we keep them foveated with smooth pursuit eye movements. Although large objects such as people and animals are common, it is nonetheless unknown how we pursue them since they cannot be foveated. It might be that the brain calculates an object's centroid, and then centers the eyes on it during pursuit as a foveation mechanism might. Alternatively, the brain merely matches the velocity by motion integration. We test these alternatives with an illusory motion stimulus that translates at a speed different from its retinal motion. The stimulus was a Gabor array that translated at a fixed velocity, with component Gabors that drifted with motion consistent or inconsistent with the translation. Velocity matching predicts different pursuit behaviors across drift conditions, while centroid matching predicts no difference. We also tested whether pursuit can segregate and ignore irrelevant local drifts when motion and centroid information are consistent by surrounding the Gabors with solid frames. Finally, observers judged the global translational speed of the Gabors to determine whether smooth pursuit and motion perception share mechanisms. We found that consistent Gabor motion enhanced pursuit gain while inconsistent, opposite motion diminished it, drawing the eyes away from the center of the stimulus and supporting a motion-based pursuit drive. Catch-up saccades tended to counter the position offset, directing the eyes opposite to the deviation caused by the pursuit gain change. Surrounding the Gabors with visible frames canceled both the gain increase and the compensatory saccades. Perceived speed was modulated analogous to pursuit gain. The results suggest that smooth pursuit of large stimuli depends on the magnitude of integrated retinal motion information, not its retinal location, and that the position system might be unnecessary for generating smooth velocity to large pursuit targets. PMID:29090315

  4. Retinotopically specific reorganization of visual cortex for tactile pattern recognition

    PubMed Central

    Cheung, Sing-Hang; Fang, Fang; He, Sheng; Legge, Gordon E.

    2009-01-01

    Although previous studies have shown that Braille reading and other tactile-discrimination tasks activate the visual cortex of blind and sighted people [1–5], it is not known whether this kind of cross-modal reorganization is influenced by retinotopic organization. We have addressed this question by studying S, a visually impaired adult with the rare ability to read print visually and Braille by touch. S had normal visual development until age six years, and thereafter severe acuity reduction due to corneal opacification, but no evidence of visual-field loss. Functional magnetic resonance imaging (fMRI) revealed that, in S’s early visual areas, tactile information processing activated what would be the foveal representation for normally-sighted individuals, and visual information processing activated what would be the peripheral representation. Control experiments showed that this activation pattern was not due to visual imagery. S’s high-level visual areas which correspond to shape- and object-selective areas in normally-sighted individuals were activated by both visual and tactile stimuli. The retinotopically specific reorganization in early visual areas suggests an efficient redistribution of neural resources in the visual cortex. PMID:19361999

  5. Using a high spatial resolution tactile sensor for intention detection.

    PubMed

    Castellini, Claudio; Koiva, Risto

    2013-06-01

    Intention detection is the interpretation of biological signals with the aim of automatically, reliably and naturally understanding what a human subject desires to do. Although intention detection is not restricted to disabled people, such methods can be crucial in improving a patient's life, e.g., aiding control of a robotic wheelchair or of a self-powered prosthesis. Traditionally, intention detection is done using, e.g., gaze tracking, surface electromyography and electroencephalography. In this paper we present exciting initial results of an experiment aimed at intention detection using a high-spatial-resolution, high-dynamic-range tactile sensor. The tactile image of the ventral side of the forearm of 9 able-bodied participants was recorded during a variable-force task stimulated at the fingertip. Both the forces at the fingertip and at the forearm were synchronously recorded. We show that a standard dimensionality reduction technique (Principal Component Analysis) plus a Support Vector Machine attain almost perfect detection accuracy of the direction and the intensity of the intended force. This paves the way for high spatial resolution tactile sensors to be used as a means for intention detection.

  6. Sustained maintenance of somatotopic information in brain regions recruited by tactile working memory.

    PubMed

    Katus, Tobias; Müller, Matthias M; Eimer, Martin

    2015-01-28

    To adaptively guide ongoing behavior, representations in working memory (WM) often have to be modified in line with changing task demands. We used event-related potentials (ERPs) to demonstrate that tactile WM representations are stored in modality-specific cortical regions, that the goal-directed modulation of these representations is mediated through hemispheric-specific activation of somatosensory areas, and that the rehearsal of somatotopic coordinates in memory is accomplished by modality-specific spatial attention mechanisms. Participants encoded two tactile sample stimuli presented simultaneously to the left and right hands, before visual retro-cues indicated which of these stimuli had to be retained to be matched with a subsequent test stimulus on the same hand. Retro-cues triggered a sustained tactile contralateral delay activity component with a scalp topography over somatosensory cortex contralateral to the cued hand. Early somatosensory ERP components to task-irrelevant probe stimuli (that were presented after the retro-cues) and to subsequent test stimuli were enhanced when these stimuli appeared at the currently memorized location relative to other locations on the cued hand, demonstrating that a precise focus of spatial attention was established during the selective maintenance of tactile events in WM. These effects were observed regardless of whether participants performed the matching task with uncrossed or crossed hands, indicating that WM representations in this task were based on somatotopic rather than allocentric spatial coordinates. In conclusion, spatial rehearsal in tactile WM operates within somatotopically organized sensory brain areas that have been recruited for information storage. Copyright © 2015 Katus et al.

  7. Transfer of tactile perceptual learning to untrained neighboring fingers reflects natural use relationships

    PubMed Central

    Harrar, Vanessa; Oliver, Jonathan; Johansen-Berg, Heidi; Spence, Charles

    2015-01-01

    Tactile learning transfers from trained to untrained fingers in a pattern that reflects overlap between the representations of fingers in the somatosensory system (e.g., neurons with multifinger receptive fields). While physical proximity on the body is known to determine the topography of somatosensory representations, tactile coactivation is also an established organizing principle of somatosensory topography. In this study we investigated whether tactile coactivation, induced by habitual inter-finger cooperative use (use pattern), shapes inter-finger overlap. To this end, we used psychophysics to compare the transfer of tactile learning from the middle finger to its adjacent fingers. This allowed us to compare transfer to two fingers that are both physically and cortically adjacent to the middle finger but have differing use patterns. Specifically, the middle finger is used more frequently with the ring than with the index finger. We predicted this should lead to greater representational overlap between the former than the latter pair. Furthermore, this difference in overlap should be reflected in differential learning transfer from the middle to index vs. ring fingers. Subsequently, we predicted temporary learning-related changes in the middle finger's representation (e.g., cortical magnification) would cause transient interference in perceptual thresholds of the ring, but not the index, finger. Supporting this, longitudinal analysis revealed a divergence where learning transfer was fast to the index finger but relatively delayed to the ring finger. Our results support the theory that tactile coactivation patterns between digits affect their topographic relationships. Our findings emphasize how action shapes perception and somatosensory organization. PMID:26631145

  8. Transfer of tactile perceptual learning to untrained neighboring fingers reflects natural use relationships.

    PubMed

    Dempsey-Jones, Harriet; Harrar, Vanessa; Oliver, Jonathan; Johansen-Berg, Heidi; Spence, Charles; Makin, Tamar R

    2016-03-01

    Tactile learning transfers from trained to untrained fingers in a pattern that reflects overlap between the representations of fingers in the somatosensory system (e.g., neurons with multifinger receptive fields). While physical proximity on the body is known to determine the topography of somatosensory representations, tactile coactivation is also an established organizing principle of somatosensory topography. In this study we investigated whether tactile coactivation, induced by habitual inter-finger cooperative use (use pattern), shapes inter-finger overlap. To this end, we used psychophysics to compare the transfer of tactile learning from the middle finger to its adjacent fingers. This allowed us to compare transfer to two fingers that are both physically and cortically adjacent to the middle finger but have differing use patterns. Specifically, the middle finger is used more frequently with the ring than with the index finger. We predicted this should lead to greater representational overlap between the former than the latter pair. Furthermore, this difference in overlap should be reflected in differential learning transfer from the middle to index vs. ring fingers. Subsequently, we predicted temporary learning-related changes in the middle finger's representation (e.g., cortical magnification) would cause transient interference in perceptual thresholds of the ring, but not the index, finger. Supporting this, longitudinal analysis revealed a divergence where learning transfer was fast to the index finger but relatively delayed to the ring finger. Our results support the theory that tactile coactivation patterns between digits affect their topographic relationships. Our findings emphasize how action shapes perception and somatosensory organization. Copyright © 2016 the American Physiological Society.

  9. A tactile sensing element based on a hetero-core optical fiber for force measurement and texture detection

    NASA Astrophysics Data System (ADS)

    Yamazaki, Hiroshi; Koyama, Yuya; Watanabe, Kazuhiro

    2014-05-01

    Tactile sensing technology can measure a given property of an object through physical contact between a sensing element and the object. Various tactile sensing techniques have been developed for several applications such as intelligent robots, tactile interface, medical support and nursing care support. A desirable tactile sensing element for supporting human daily life can be embedded in the soft material with high sensitivity and accuracy in order to prevent from damaging to human or object physically. This report describes a new tactile sensing element. Hetero-core optical fibers have high sensitivity of macro-bending at local sensor portion and temperature independency, including advantages of optical fiber itself; thin size, light weight, flexible transmission line, and immunity to electro-magnetic interference. The proposed tactile sensing element could detect textures of touched objects through the optical loss caused by the force applied to the sensing element. The characteristics of the sensing element have been evaluated, in which the sensing element has the monotonic and non-linear sensitivity against the normal force ranged from 0 to 5 N with lower accuracy than 0.25 dB. Additionally, texture detection have been successfully demonstrated in which small surface figures of 0.1 mm in height were detected with spatial resolution of 0.4 mm.

  10. Risk prediction and impaired tactile sensory perception among cancer patients during chemotherapy.

    PubMed

    Cardoso, Ana Carolina Lima Ramos; Araújo, Diego Dias de; Chianca, Tânia Couto Machado

    2018-01-08

    to estimate the prevalence of impaired tactile sensory perception, identify risk factors, and establish a risk prediction model among adult patients receiving antineoplastic chemotherapy. historical cohort study based on information obtained from the medical files of 127 patients cared for in the cancer unit of a private hospital in a city in Minas Gerais, Brazil. Data were analyzed using descriptive and bivariate statistics, with survival and multivariate analysis by Cox regression. 57% of the 127 patients included in the study developed impaired tactile sensory perception. The independent variables that caused significant impact, together with time elapsed from the beginning of treatment up to the onset of the condition, were: bone, hepatic and regional lymph node metastases; alcoholism; palliative chemotherapy; and discomfort in lower limbs. impaired tactile sensory perception was common among adult patients during chemotherapy, indicating the need to implement interventions designed for early identification and treatment of this condition.

  11. The Influence of Tactile Cognitive Maps on Auditory Space Perception in Sighted Persons.

    PubMed

    Tonelli, Alessia; Gori, Monica; Brayda, Luca

    2016-01-01

    We have recently shown that vision is important to improve spatial auditory cognition. In this study, we investigate whether touch is as effective as vision to create a cognitive map of a soundscape. In particular, we tested whether the creation of a mental representation of a room, obtained through tactile exploration of a 3D model, can influence the perception of a complex auditory task in sighted people. We tested two groups of blindfolded sighted people - one experimental and one control group - in an auditory space bisection task. In the first group, the bisection task was performed three times: specifically, the participants explored with their hands the 3D tactile model of the room and were led along the perimeter of the room between the first and the second execution of the space bisection. Then, they were allowed to remove the blindfold for a few minutes and look at the room between the second and third execution of the space bisection. Instead, the control group repeated for two consecutive times the space bisection task without performing any environmental exploration in between. Considering the first execution as a baseline, we found an improvement in the precision after the tactile exploration of the 3D model. Interestingly, no additional gain was obtained when room observation followed the tactile exploration, suggesting that no additional gain was obtained by vision cues after spatial tactile cues were internalized. No improvement was found between the first and the second execution of the space bisection without environmental exploration in the control group, suggesting that the improvement was not due to task learning. Our results show that tactile information modulates the precision of an ongoing space auditory task as well as visual information. This suggests that cognitive maps elicited by touch may participate in cross-modal calibration and supra-modal representations of space that increase implicit knowledge about sound propagation.

  12. Method and device for producing a tactile display using an electrorheological fluid

    NASA Technical Reports Server (NTRS)

    Garner, H. Douglas (Inventor)

    1996-01-01

    A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

  13. Cassini Scientist for a Day: a tactile experience

    NASA Astrophysics Data System (ADS)

    Canas, L.; Altobelli, N.

    2012-09-01

    In September 2011, the Cassini spacecraft took images of three targets and a challenge was launched to all students: to choose the one target they thought would provide the best science and to write an essay explaining their reasons (more information on the "Cassini Scientist for a Day" essay contest official webpage in: http://saturn.jpl.nasa.gov/education/scientistforaday10thedition/, run by NASA/JPL) The three targets presented were: Hyperion, Rhea and Titan, and Saturn. The idea behind "Cassini Scientist for a Day: a tactile experience" was to transform each of these images into schematic tactile images, highlighting relevant features apprehended through a tactile key, accompanied by a small text in Braille with some additional information. This initial approach would allow reach a broader community of students, more specifically those with visual impairment disabilities. Through proper implementation and careful study cases the adapted images associated with an explanatory key provide more resources in tactile astronomy. As the 2012 edition approaches a new set of targeted objet images will be once again transformed and adapted to visually impaired students and will aim to reach more students into participate in this international competition and to engage them in a quest to expand their knowledge in the amazing Cassini discoveries and the wonders of Saturn and its moons. As the winning essays will be published on the Cassini website and contest winners invited to participate in a dedicated teleconference with Cassini scientists from NASA's Jet Propulsion Laboratory, this initiative presents a great chance to all visually impaired students and teachers to participate in an exciting experience. These initiatives must be complemented with further information to strengthen the learning experience. However they stand as a good starting point to tackle further astronomical concepts in the classroom, especially this field that sometimes lacks the resources. Although

  14. Detection of fever in children emergency care: comparisons of tactile and rectal temperatures in Nigerian children

    PubMed Central

    2010-01-01

    Background Clinical thermometry is the objective method for temperature measurements but tactile assessment of fever at home is usually the basis for seeking medical attention especially where the cost and level of literacy preclude the use of thermometers. This study was carried out to determine the reliability of tactile perception of fever by caregivers, nurses and house physicians in comparison to rectal thermometry and also the use of commonly practiced surface of the hand in the care of ill children. All caregivers of children aged 6 to 59 months who presented to the emergency department were approached consecutively at the triage stage but 182 children participated. Each child had tactile assessment of fever using palmar and dorsal surfaces of the hand by the caregivers, House Physicians and Nursing Officers. Rectal temperature was also measured and read independently by nurses and house physicians. Comparisons were made between tactile assessments and thermometer readings using a cut-off for fever, 38.0°C and above. Findings The caregivers' perception of fever had a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 95%, 23%, 66% and 73%, respectively compared with 93%, 26%, 67% and 69%, respectively for nursing officers. Irrespective of the groups studied, 77.1% of 336 assessors opined that the dorsal surface of the hand was more sensitive in tactile assessment of temperature and the frequently used site for assessment of fever were the head (35.6%) and neck (33.3%). Tactile assessment of temperature over-detected fever in ≥ 24% of cases among the three groups of assessors. Conclusions The present study suggests that tactile assessment of temperature may over estimate the prevalence of fever, it does not detect some cases and the need for objective measurement of temperature is emphasised in paediatric emergency care. PMID:20406473

  15. Role of combined tactile and kinesthetic feedback in minimally invasive surgery.

    PubMed

    Lim, Soo-Chul; Lee, Hyung-Kew; Park, Joonah

    2014-10-18

    Haptic feedback is of critical importance in surgical tasks. However, conventional surgical robots do not provide haptic feedback to surgeons during surgery. Thus, in this study, a combined tactile and kinesthetic feedback system was developed to provide haptic feedback to surgeons during robotic surgery. To assess haptic feasibility, the effects of two types of haptic feedback were examined empirically - kinesthetic and tactile feedback - to measure object-pulling force with a telesurgery robotics system at two desired pulling forces (1 N and 2 N). Participants answered a set of questionnaires after experiments. The experimental results reveal reductions in force error (39.1% and 40.9%) when using haptic feedback during 1 N and 2 N pulling tasks. Moreover, survey analyses show the effectiveness of the haptic feedback during teleoperation. The combined tactile and kinesthetic feedback of the master device in robotic surgery improves the surgeon's ability to control the interaction force applied to the tissue. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Psychophysical evaluation of a variable friction tactile interface

    NASA Astrophysics Data System (ADS)

    Samur, Evren; Colgate, J. Edward; Peshkin, Michael A.

    2009-02-01

    This study explores the haptic rendering capabilities of a variable friction tactile interface through psychophysical experiments. In order to obtain a deeper understanding of the sensory resolution associated with the Tactile Pattern Display (TPaD), friction discrimination experiments are conducted. During the experiments, subjects are asked to explore the glass surface of the TPaD using their bare index fingers, to feel the friction on the surface, and to compare the slipperiness of two stimuli, displayed in sequential order. The fingertip position data is collected by an infrared frame and normal and translational forces applied by the finger are measured by force sensors attached to the TPaD. The recorded data is used to calculate the coefficient of friction between the fingertip and the TPaD. The experiments determine the just noticeable difference (JND) of friction coefficient for humans interacting with the TPaD.

  17. Pain intensity attenuates movement control of the lumbar spine in low back pain.

    PubMed

    Bauer, C M; Rast, F M; Ernst, M J; Oetiker, S; Meichtry, A; Kool, J; Rissanen, S M; Suni, J H; Kankaanpää, M

    2015-12-01

    Pain intensity attenuates muscular activity, proprioception, and tactile acuity, with consequent changes of joint kinematics. People suffering from low back pain (LBP) frequently show movement control impairments of the lumbar spine in sagittal plane. This cross-sectional, observational study investigated if the intensity of LBP attenuates lumbar movement control. The hypothesis was that lumbar movement control becomes more limited with increased pain intensity. The effect of LBP intensity, measured with a numeric rating scale (NRS), on lumbar movement control was tested using three movement control tests. The lumbar range of motion (ROM), the ratio of lumbar and hip ROM as indicators of direction specific movement control, and the recurrence and determinism of repetitive lumbar movement patterns were assessed in ninety-four persons suffering from LBP of different intensity and measured with an inertial measurement unit system. Generalized linear models were fitted for each outcome. Lumbar ROM (+ 0.03°, p = 0.24) and ratio of lumbar and hip ROM (0.01, p = 0.84) were unaffected by LBP intensity. Each one point increase on the NRS resulted in a decrease of recurrence and determinism of lumbar movement patterns (-3.11 to -0.06, p ⩽ 0.05). Our results indicate changes in movement control in people suffering from LBP. Whether decreased recurrence and determinism of lumbar movement patterns are intensifiers of LBP intensity or a consequence thereof should be addressed in a future prospective study. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Plasticity of illusory vowel perception in Brazilian-Japanese bilinguals.

    PubMed

    Parlato-Oliveira, Erika; Christophe, Anne; Hirose, Yuki; Dupoux, Emmanuel

    2010-06-01

    Previous research shows that monolingual Japanese and Brazilian Portuguese listeners perceive illusory vowels (/u/ and /i/, respectively) within illegal sequences of consonants. Here, several populations of Japanese-Brazilian bilinguals are tested, using an explicit vowel identification task (experiment 1), and an implicit categorization and sequence recall task (experiment 2). Overall, second-generation immigrants, who first acquired Japanese at home and Brazilian during childhood (after age 4) showed a typical Brazilian pattern of result (and so did simultaneous bilinguals, who were exposed to both languages from birth on). In contrast, late bilinguals, who acquired their second language in adulthood, exhibited a pattern corresponding to their native language. In addition, an influence of the second language was observed in the explicit task of Exp. 1, but not in the implicit task used in Exp. 2, suggesting that second language experience affects mostly explicit or metalinguistic skills. These results are compared to other studies of phonological representations in adopted children or immigrants, and discussed in relation to the role of age of acquisition and sociolinguistic factors.

  19. Good vibrations: tactile feedback in support of attention allocation and human-automation coordination in event-driven domains.

    PubMed

    Sklar, A E; Sarter, N B

    1999-12-01

    Observed breakdowns in human-machine communication can be explained, in part, by the nature of current automation feedback, which relies heavily on focal visual attention. Such feedback is not well suited for capturing attention in case of unexpected changes and events or for supporting the parallel processing of large amounts of data in complex domains. As suggested by multiple-resource theory, one possible solution to this problem is to distribute information across various sensory modalities. A simulator study was conducted to compare the effectiveness of visual, tactile, and redundant visual and tactile cues for indicating unexpected changes in the status of an automated cockpit system. Both tactile conditions resulted in higher detection rates for, and faster response times to, uncommanded mode transitions. Tactile feedback did not interfere with, nor was its effectiveness affected by, the performance of concurrent visual tasks. The observed improvement in task-sharing performance indicates that the introduction of tactile feedback is a promising avenue toward better supporting human-machine communication in event-driven, information-rich domains.

  20. A Corticothalamic Circuit for Refining Tactile Encoding.

    PubMed

    Pauzin, François Philippe; Krieger, Patrik

    2018-05-01

    A fundamental task for the brain is to determine which aspects of the continuous flow of information is the most relevant in a given behavioral situation. The information flow is regulated via dynamic interactions between feedforward and feedback pathways. One such pathway is via corticothalamic feedback. Layer 6 (L6) corticothalamic (CT) cells make both cortical and thalamic connections and, therefore, are key modulators of activity in both areas. The functional properties of L6 CT cells in sensory processing were investigated in the mouse whisker system. Optogenetic activation of L6 CT neurons decreased spontaneous spiking, with the net effect that a whisker-evoked response was more accurately detected (larger evoked-to-spontaneous spiking ratio) but at the expense of reducing the response probability. In addition, L6 CT activation decreases sensory adaptation in both the thalamus and cortex. L6 CT activity can thus tune the tactile system, depending on the behaviorally relevant tactile input. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Tactile and bone-conduction auditory brain computer interface for vision and hearing impaired users.

    PubMed

    Rutkowski, Tomasz M; Mori, Hiromu

    2015-04-15

    The paper presents a report on the recently developed BCI alternative for users suffering from impaired vision (lack of focus or eye-movements) or from the so-called "ear-blocking-syndrome" (limited hearing). We report on our recent studies of the extents to which vibrotactile stimuli delivered to the head of a user can serve as a platform for a brain computer interface (BCI) paradigm. In the proposed tactile and bone-conduction auditory BCI novel multiple head positions are used to evoke combined somatosensory and auditory (via the bone conduction effect) P300 brain responses, in order to define a multimodal tactile and bone-conduction auditory brain computer interface (tbcaBCI). In order to further remove EEG interferences and to improve P300 response classification synchrosqueezing transform (SST) is applied. SST outperforms the classical time-frequency analysis methods of the non-linear and non-stationary signals such as EEG. The proposed method is also computationally more effective comparing to the empirical mode decomposition. The SST filtering allows for online EEG preprocessing application which is essential in the case of BCI. Experimental results with healthy BCI-naive users performing online tbcaBCI, validate the paradigm, while the feasibility of the concept is illuminated through information transfer rate case studies. We present a comparison of the proposed SST-based preprocessing method, combined with a logistic regression (LR) classifier, together with classical preprocessing and LDA-based classification BCI techniques. The proposed tbcaBCI paradigm together with data-driven preprocessing methods are a step forward in robust BCI applications research. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Object-based warping: an illusory distortion of space within objects.

    PubMed

    Vickery, Timothy J; Chun, Marvin M

    2010-12-01

    Visual objects are high-level primitives that are fundamental to numerous perceptual functions, such as guidance of attention. We report that objects warp visual perception of space in such a way that spatial distances within objects appear to be larger than spatial distances in ground regions. When two dots were placed inside a rectangular object, they appeared farther apart from one another than two dots with identical spacing outside of the object. To investigate whether this effect was object based, we measured the distortion while manipulating the structure surrounding the dots. Object displays were constructed with a single object, multiple objects, a partially occluded object, and an illusory object. Nonobject displays were constructed to be comparable to object displays in low-level visual attributes. In all cases, the object displays resulted in a more powerful distortion of spatial perception than comparable non-object-based displays. These results suggest that perception of space within objects is warped.

  3. Noncontact Tactile Display Based on Radiation Pressure of Airborne Ultrasound.

    PubMed

    Hoshi, T; Takahashi, M; Iwamoto, T; Shinoda, H

    2010-01-01

    This paper describes a tactile display which provides unrestricted tactile feedback in air without any mechanical contact. It controls ultrasound and produces a stress field in a 3D space. The principle is based on a nonlinear phenomenon of ultrasound: Acoustic radiation pressure. The fabricated prototype consists of 324 airborne ultrasound transducers, and the phase and intensity of each transducer are controlled individually to generate a focal point. The DC output force at the focal point is 16 mN and the diameter of the focal point is 20 mm. The prototype produces vibrations up to 1 kHz. An interaction system including the prototype is also introduced, which enables users to see and touch virtual objects.

  4. When touch matters: an affective tactile intervention for older adults.

    PubMed

    Mammarella, Nicola; Fairfield, Beth; Di Domenico, Alberto

    2012-10-01

    Our goal was to test the hypothesis that positive tactile experiences can lead to an improvement in cognitive, emotional skills and perceived quality of life in a group of healthy community-dwelling older adults. During a 10-week period, older adults completed a series of activities that required manipulating either a piece of velvet, a piece of canvas or velcro. Only older adults who worked with velvet showed an increase in cognitive and emotional skills, and the perceived quality of life. Our study is one of the first to show that positive tactile experiences might have a beneficial effect on the psychological well-being of healthy community-dwelling older adults across different domains. © 2012 Japan Geriatrics Society.

  5. Illusory ownership of a virtual child body causes overestimation of object sizes and implicit attitude changes

    PubMed Central

    Banakou, Domna; Groten, Raphaela; Slater, Mel

    2013-01-01

    An illusory sensation of ownership over a surrogate limb or whole body can be induced through specific forms of multisensory stimulation, such as synchronous visuotactile tapping on the hidden real and visible rubber hand in the rubber hand illusion. Such methods have been used to induce ownership over a manikin and a virtual body that substitute the real body, as seen from first-person perspective, through a head-mounted display. However, the perceptual and behavioral consequences of such transformed body ownership have hardly been explored. In Exp. 1, immersive virtual reality was used to embody 30 adults as a 4-y-old child (condition C), and as an adult body scaled to the same height as the child (condition A), experienced from the first-person perspective, and with virtual and real body movements synchronized. The result was a strong body-ownership illusion equally for C and A. Moreover there was an overestimation of the sizes of objects compared with a nonembodied baseline, which was significantly greater for C compared with A. An implicit association test showed that C resulted in significantly faster reaction times for the classification of self with child-like compared with adult-like attributes. Exp. 2 with an additional 16 participants extinguished the ownership illusion by using visuomotor asynchrony, with all else equal. The size-estimation and implicit association test differences between C and A were also extinguished. We conclude that there are perceptual and probably behavioral correlates of body-ownership illusions that occur as a function of the type of body in which embodiment occurs. PMID:23858436

  6. Does the sight of physical threat induce a tactile processing bias? Modality-specific attentional facilitation induced by viewing threatening pictures.

    PubMed

    Van Damme, Stefaan; Gallace, Alberto; Spence, Charles; Crombez, Geert; Moseley, G Lorimer

    2009-02-09

    Threatening stimuli are thought to bias spatial attention toward the location from which the threat is presented. Although this effect is well-established in the visual domain, little is known regarding whether tactile attention is similarly affected by threatening pictures. We hypothesised that tactile attention might be more affected by cues implying physical threat to a person's bodily tissues than by cues implying general threat. In the present study, participants made temporal order judgments (TOJs) concerning which of a pair of tactile (or auditory) stimuli, one presented to either hand, at a range of inter-stimulus intervals, had been presented first. A picture (showing physical threat, general threat, or no threat) was presented in front of one or the other hand shortly before the tactile stimuli. The results revealed that tactile attention was biased toward the side on which the picture was presented, and that this effect was significantly larger for physical threat pictures than for general threat or neutral pictures. By contrast, the bias in auditory attention toward the side of the picture was significantly larger for general threat pictures than for physical threat pictures or neutral pictures. These findings therefore demonstrate a modality-specific effect of physically threatening cues on the processing of tactile stimuli, and of generally threatening cues on auditory information processing. These results demonstrate that the processing of tactile information from the body part closest to the threatening stimulus is prioritized over tactile information from elsewhere on the body.

  7. Functional consequences of experience-dependent plasticity on tactile perception following perceptual learning

    PubMed Central

    Trzcinski, Natalie K; Gomez-Ramirez, Manuel; Hsiao, Steven S.

    2016-01-01

    Continuous training enhances perceptual discrimination and promotes neural changes in areas encoding the experienced stimuli. This type of experience-dependent plasticity has been demonstrated in several sensory and motor systems. Particularly, non-human primates trained to detect consecutive tactile bar indentations across multiple digits showed expanded excitatory receptive fields (RFs) in somatosensory cortex. However, the perceptual implications of these anatomical changes remain undetermined. Here, we trained human participants for nine days on a tactile task that promoted expansion of multi-digit RFs. Participants were required to detect consecutive indentations of bar stimuli spanning multiple digits. Throughout the training regime we tracked participants’ discrimination thresholds on spatial (grating orientation) and temporal tasks on the trained and untrained hands in separate sessions. We hypothesized that training on the multi-digit task would decrease perceptual thresholds on tasks that require stimulus processing across multiple digits, while also increasing thresholds on tasks requiring discrimination on single digits. We observed an increase in orientation thresholds on a single-digit. Importantly, this effect was selective for the stimulus orientation and hand used during multi-digit training. We also found that temporal acuity between digits improved across trained digits, suggesting that discriminating the temporal order of multi-digit stimuli can transfer to temporal discrimination of other tactile stimuli. These results suggest that experience-dependent plasticity following perceptual learning improves and interferes with tactile abilities in manners predictive of the task and stimulus features used during training. PMID:27422224

  8. A case of cervico-brachial disorder due to tactile interpretation for deaf-blind persons.

    PubMed

    Kitahara, Teruyo; Nakamura, Kenji; Taoda, Kazushi; Shigeta, Hiromasa; Hirata, Mamoru

    2012-01-01

    We herein report a case of cervico-brachial disorder (CBD) due to long-term tactile interpreting. The patient was interviewed to investigate her past history, occupational history, work conditions and clinical course in detail. The case was diagnosed in accordance with the "Diagnostic Criteria for CBD 2007" established by the Research Association for CBD of the Japanese Society for Occupational Health. The patient was a 49-year-old female who has worked as a regular occupational instructor at a welfare work activity center for deaf people since April 22, 2010. Her primary job is to instruct and aid others in learning confectionery manufacturing and coffee shop tasks. She also performs tactile interpreting for two deaf-blind workers during a morning health check and during any meetings. On September 3, 2010, she interpreted by tactile signing for about three hours alone during a meeting, due to the absence of other interpreters. She developed severe pain in her back immediately after carrying out this interpretation, and the pain thereafter continued and developed in the upper extremities. She was diagnosed with a severe and prolonged case of the non-specific type of CBD. Interpretation by tactile signing may impose a heavier burden on the upper extremities, shoulders and neck than that imposed by common sign language. A shorter time of interpretation, ensuring the availability of rest time and supporting tools or methods for the upper extremities, are therefore considered to be necessary to prevent the incidence of CBD among interpreters using tactile signing.

  9. Tactile discrimination activates the visual cortex of the recently blind naive to Braille: a functional magnetic resonance imaging study in humans.

    PubMed

    Sadato, Norihiro; Okada, Tomohisa; Kubota, Kiyokazu; Yonekura, Yoshiharu

    2004-04-08

    The occipital cortex of blind subjects is known to be activated during tactile discrimination tasks such as Braille reading. To investigate whether this is due to long-term learning of Braille or to sensory deafferentation, we used fMRI to study tactile discrimination tasks in subjects who had recently lost their sight and never learned Braille. The occipital cortex of the blind subjects without Braille training was activated during the tactile discrimination task, whereas that of control sighted subjects was not. This finding suggests that the activation of the visual cortex of the blind during performance of a tactile discrimination task may be due to sensory deafferentation, wherein a competitive imbalance favors the tactile over the visual modality.

  10. Self-motion perception: assessment by real-time computer-generated animations

    NASA Technical Reports Server (NTRS)

    Parker, D. E.; Phillips, J. O.

    2001-01-01

    We report a new procedure for assessing complex self-motion perception. In three experiments, subjects manipulated a 6 degree-of-freedom magnetic-field tracker which controlled the motion of a virtual avatar so that its motion corresponded to the subjects' perceived self-motion. The real-time animation created by this procedure was stored using a virtual video recorder for subsequent analysis. Combined real and illusory self-motion and vestibulo-ocular reflex eye movements were evoked by cross-coupled angular accelerations produced by roll and pitch head movements during passive yaw rotation in a chair. Contrary to previous reports, illusory self-motion did not correspond to expectations based on semicircular canal stimulation. Illusory pitch head-motion directions were as predicted for only 37% of trials; whereas, slow-phase eye movements were in the predicted direction for 98% of the trials. The real-time computer-generated animations procedure permits use of naive, untrained subjects who lack a vocabulary for reporting motion perception and is applicable to basic self-motion perception studies, evaluation of motion simulators, assessment of balance disorders and so on.

  11. Greater tactile sensitivity and less use of immature psychological defense mechanisms predict women's penile-vaginal intercourse orgasm.

    PubMed

    Brody, Stuart; Houde, Stephanie; Hess, Ursula

    2010-09-01

    Previous research has suggested that diminished tactile sensitivity might be associated with reduced sexual activity and function. Research has also demonstrated significant physiological and psychological differences between sexual behaviors, including immature psychological defense mechanisms (associated with various psychopathologies) impairing specifically women's orgasm from penile-vaginal intercourse (PVI). To examine the extent to which orgasm triggered by PVI (distinguished from other sexual activities) is associated with both greater tactile sensitivity and lesser use of immature psychological defenses. Seventy French-Canadian female university students (aged 18-30) had their finger sensitivity measured with von Frey type microfilaments, completed the Defense Style Questionnaire and a short form of the Marlowe-Crowne social desirability scale, and provided details of the 1 month (and ever) frequencies of engaging in, and having an orgasm from, PVI, masturbation, anal intercourse, partner masturbation, and cunnilingus. Logistic and linear regression prediction of orgasm triggered by PVI from tactile sensitivity, age, social desirability responding, and immature psychological defenses. Having a PVI orgasm in the past month was associated with greater tactile sensitivity (odds ratio=4.0 for each filament point) and less use of immature defense mechanisms (odds ratio=5.1 for each scale point). Lifetime PVI orgasm was associated only with less use of immature defense mechanisms (and lower social desirability responding score). Orgasms triggered by other activities were not associated with either tactile sensitivity or immature defense mechanisms. Tactile sensitivity was also associated with greater past month PVI frequency (inclusion of PVI frequency in a logistic regression model displaced tactile sensitivity), and lesser use of immature defenses was associated with greater past month PVI and PVI orgasm frequencies. Both diminished physical sensitivity and the

  12. Application of tactile/kinesthetic stimulation in preterm infants: a systematic review.

    PubMed

    Pepino, Vanessa C; Mezzacappa, Maria Aparecida

    2015-01-01

    To verify the methods used by the clinical trials that assessed the effect of tactile/kinesthetic stimulation on weight gain in preterm infants and highlight the similarities and differences among such studies. This review collected studies from two databases, PEDro and PubMed, in July of 2014, in addition to bibliographies. Two researchers assessed the relevant titles independently, and then chose which studies to read in full and include in this review by consensus. Clinical trials that studied tactile stimulation or massage therapy whether or not associated with kinesthetic stimulation of preterm infants; that assessed weight gain after the intervention; that had a control group and were composed in English, Portuguese, or Spanish were included. A total of 520 titles were found and 108 were selected for manuscript reading. Repeated studies were excluded, resulting in 40 different studies. Of these, 31 met all the inclusion criteria. There were many differences in the application of tactile/kinesthetic stimulation techniques among studies, which hindered the accurate reproduction of the procedure. Also, many studies did not describe the adverse events that occurred during stimulation, the course of action taken when such events occurred, and their effect on the outcome. These studies made a relevant contribution towards indicating tactile/kinesthetic stimulation as a promising tool. Nevertheless, there was no standard for application among them. Future studies should raise the level of methodological rigor and describe the adverse events. This may permit other researchers to be more aware of expected outcomes, and a standard technique could be established. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  13. Simultaneous Stimulus Preexposure Enhances Human Tactile Perceptual Learning

    ERIC Educational Resources Information Center

    Rodríguez, Gabriel; Angulo, Rocío

    2014-01-01

    An experiment with human participants established a novel procedure to assess perceptual learning with tactile stimuli. Participants received unsupervised exposure to two sandpaper surfaces differing in roughness (A and B). The ability of the participants to discriminate between the stimuli was subsequently assessed on a same/different test. It…

  14. Tactile sensor is useful for estimating liver hardness and liver fibrosis compared with ultrasonography and computed tomography.

    PubMed

    Suzuki, Satoshi; Watanabe, Yohei; Yazawa, Takashi; Ishigame, Teruhide; Sassa, Motoki; Monma, Tomoyuki; Takawa, Tadashi; Kumamoto, Kensuke; Nakamura, Izumi; Ohoki, Shinji; Hatakeyama, Yuichi; Sakuma, Hiroshi; Ono, Toshiyuki; Omata, Sadao; Takenoshita, Seiichi

    2014-01-01

    We examined whether conventional ultrasonography (US) and computed tomography (CT) were useful to evaluate liver hardness and hepatic fibrosis by comparing the results with those obtained by a tactile sensor using rats with liver fibrosis. We used 44 Wistar rats in which liver fibrosis was induced by intraperitoneal administration of thioacetamide. The CT and US values of each liver were measured before laparotomy. After laparotomy, a tactile sensor was used to measure liver hardness. We prepared Azan stained sections of each excised liver specimen and calculated the degree of liver fibrosis (HFI: hepatic fibrosis index) by computed color image analysis. The stiffness values and HFI showed a positive correlation (r=0.690, p<0.001), as did the tactile values and HFI (r=0.709, p<0.001).In addition, the stiffness and tactile values correlated positively with each other (r=0.814, p<0.001). There was no correlation between the CT values and HFI, as well as no correlation between the US values and HFI. We confirmed that it was difficult to evaluate liver hardness and HFI by CT or US examination, and considered that, at present, a tactile sensor is useful method for evaluating HFI.

  15. Rendering edge enhancement tactile phenomenon by friction variation in dynamic touch.

    PubMed

    Abdolvahab, Mohammad

    2011-01-04

    Variable friction tactile displays have been recently used to render virtual textures and gratings. Neural basis of perceptual mechanism of detection of edge-like features resulting in discrimination of virtual gratings during active touching these tactile actuators is studied using a finite-element biomechanical model of human fingertip. The predicted neural response of the mechanoreceptors, i.e. the computed strain energy density at the location of selected mechanoreceptors as a measure of neural discharge rate of the corresponding receptors, to local reduction of friction between fingerpad and surface are shown to exhibit a similar shape as the edge enhancement phenomenon, particularly in a sudden burst at the boundary of variable friction regions. This phenomenon is supposed to account for the illusion of virtual edges rendered through the modification of contact forces. The presence of this sudden burst under varied model parameters was investigated. It was shown that while the appearance of this phenomenon in simulation results was invariant to model parameters, associated alteration of the edge enhancement ratio might be considered for the purpose of the tuning of the variable friction tactile display. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Audio-Tactile Integration in Congenitally and Late Deaf Cochlear Implant Users

    PubMed Central

    Nava, Elena; Bottari, Davide; Villwock, Agnes; Fengler, Ineke; Büchner, Andreas; Lenarz, Thomas; Röder, Brigitte

    2014-01-01

    Several studies conducted in mammals and humans have shown that multisensory processing may be impaired following congenital sensory loss and in particular if no experience is achieved within specific early developmental time windows known as sensitive periods. In this study we investigated whether basic multisensory abilities are impaired in hearing-restored individuals with deafness acquired at different stages of development. To this aim, we tested congenitally and late deaf cochlear implant (CI) recipients, age-matched with two groups of hearing controls, on an audio-tactile redundancy paradigm, in which reaction times to unimodal and crossmodal redundant signals were measured. Our results showed that both congenitally and late deaf CI recipients were able to integrate audio-tactile stimuli, suggesting that congenital and acquired deafness does not prevent the development and recovery of basic multisensory processing. However, we found that congenitally deaf CI recipients had a lower multisensory gain compared to their matched controls, which may be explained by their faster responses to tactile stimuli. We discuss this finding in the context of reorganisation of the sensory systems following sensory loss and the possibility that these changes cannot be “rewired” through auditory reafferentation. PMID:24918766

  17. Audio-tactile integration in congenitally and late deaf cochlear implant users.

    PubMed

    Nava, Elena; Bottari, Davide; Villwock, Agnes; Fengler, Ineke; Büchner, Andreas; Lenarz, Thomas; Röder, Brigitte

    2014-01-01

    Several studies conducted in mammals and humans have shown that multisensory processing may be impaired following congenital sensory loss and in particular if no experience is achieved within specific early developmental time windows known as sensitive periods. In this study we investigated whether basic multisensory abilities are impaired in hearing-restored individuals with deafness acquired at different stages of development. To this aim, we tested congenitally and late deaf cochlear implant (CI) recipients, age-matched with two groups of hearing controls, on an audio-tactile redundancy paradigm, in which reaction times to unimodal and crossmodal redundant signals were measured. Our results showed that both congenitally and late deaf CI recipients were able to integrate audio-tactile stimuli, suggesting that congenital and acquired deafness does not prevent the development and recovery of basic multisensory processing. However, we found that congenitally deaf CI recipients had a lower multisensory gain compared to their matched controls, which may be explained by their faster responses to tactile stimuli. We discuss this finding in the context of reorganisation of the sensory systems following sensory loss and the possibility that these changes cannot be "rewired" through auditory reafferentation.

  18. Visual and tactile information in double bass intonation control.

    PubMed

    Lage, Guilherme Menezes; Borém, Fausto; Vieira, Maurílio Nunes; Barreiros, João Pardal

    2007-04-01

    Traditionally, the teaching of intonation on the non-tempered orchestral strings (violin, viola, cello, and double bass) has resorted to the auditory and proprioceptive senses only. This study aims at understanding the role of visual and tactile information in the control of the non-tempered intonation of the acoustic double bass. Eight musicians played 11 trials of an atonal sequence of musical notes on two double basses of different sizes under different sensorial constraints. The accuracy of the played notes was analyzed by measuring their frequencies and comparing them with respective target values. The main finding was that the performance which integrated visual and tactile information was superior in relation to the other performances in the control of double bass intonation. This contradicts the traditional belief that proprioception and hearing are the most effective feedback information in the performance of stringed instruments.

  19. Ageing effects on the diameter, nanomechanical properties and tactile perception of human hair.

    PubMed

    Tang, W; Zhang, S G; Zhang, J K; Chen, S; Zhu, H; Ge, S R

    2016-04-01

    The typical changes to hair associated with ageing are greying, thinning, dryness and brittleness. Research on the influence of ageing on hair properties will enable a detailed understanding of the natural ageing process. The studies were carried out using an SEM (scanning electron microscope), a TriboIndenter and an artificial finger. Three characteristic features of tactile perception that could reflect the perceptual dimensions of the fineness, roughness and slipperiness of hair were extracted. The influences of ageing on the diameter, surface topography, nanomechanical properties and tactile perception of hair were determined. In the three age group hair samples, the children's group hair samples have the smallest diameter. The hair cuticles in the children and young adult groups were relatively complete and less damaged than in the elderly group. The hardness and elastic modulus of the young adult group's hair samples were higher than those in the elderly and children's groups. For all groups, loss modulus E" was smaller than storage modulus E'. Vertical deviations (R) and coefficient of friction (μ) increased, and spectral centroid (SC) decreased, with the increase in age. Ageing decreased the tactile perception of hair. Ageing influences the diameter, surface topography, hardness, loss modulus, storage modulus and tactile perception of human hair. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  20. Effects of Visual, Auditory, and Tactile Alerts on Platoon Leader Performance and Decision Making

    DTIC Science & Technology

    2005-12-01

    Effects of Visual, Auditory, and Tactile Alerts on Platoon Leader Performance and Decision Making by Andrea S . Krausman, Linda R. Elliott...Tactile Alerts on Platoon Leader Performance and Decision Making Andrea S . Krausman, Linda R. Elliott, and Rodger A. Pettitt Human Research and...Platoon Leader Performance and Decision Making 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 62716AH70 5e. TASK NUMBER 6. AUTHOR( S

  1. A User Study on Tactile Graphic Generation Methods

    ERIC Educational Resources Information Center

    Krufka, S. E.; Barner, K. E.

    2006-01-01

    Methods to automatically convert graphics into tactile representations have been recently investigated, creating either raised-line or relief images. In particular, we briefly review one raised-line method where important features are emphasized. This paper focuses primarily on the effects of such emphasis and on comparing both raised-line and…

  2. The recalibration of tactile perception during tool use is body-part specific

    PubMed Central

    Cawley-Bennett, Andrew; Longo, Matthew R.; Saygin, Ayse P.

    2018-01-01

    Two decades of research have demonstrated that using a tool modulates spatial representations of the body. Whether this embodiment is specific to representations of the tool-using limb or extends to representations of other body parts has received little attention. Several studies of other perceptual phenomena have found that modulations to the primary somatosensory representation of the hand transfers to the face, due in part to their close proximity in primary somatosensory cortex. In the present study, we investigated whether tool-induced recalibration of tactile perception on the hand transfers to the cheek. Participants verbally estimated the distance between two tactile points applied to either their hand or face, before and after using a hand-shaped tool. Tool use recalibrated tactile distance perception on the hand—in line with previous findings—but left perception on the cheek unchanged. This finding provides support for the idea that embodiment is body-part specific. Furthermore, it suggests that tool-induced perceptual recalibration occurs at a level of somatosensory processing, where representations of the hand and face have become functionally disentangled. PMID:28702834

  3. Bilateral Saccadic Eye Movements and Tactile Stimulation, but Not Auditory Stimulation, Enhance Memory Retrieval

    ERIC Educational Resources Information Center

    Nieuwenhuis, Sander; Elzinga, Bernet M.; Ras, Priscilla H.; Berends, Floris; Duijs, Peter; Samara, Zoe; Slagter, Heleen A.

    2013-01-01

    Recent research has shown superior memory retrieval when participants make a series of horizontal saccadic eye movements between the memory encoding phase and the retrieval phase compared to participants who do not move their eyes or move their eyes vertically. It has been hypothesized that the rapidly alternating activation of the two hemispheres…

  4. Computational optical palpation: a finite-element approach to micro-scale tactile imaging using a compliant sensor

    PubMed Central

    Sampson, David D.; Kennedy, Brendan F.

    2017-01-01

    High-resolution tactile imaging, superior to the sense of touch, has potential for future biomedical applications such as robotic surgery. In this paper, we propose a tactile imaging method, termed computational optical palpation, based on measuring the change in thickness of a thin, compliant layer with optical coherence tomography and calculating tactile stress using finite-element analysis. We demonstrate our method on test targets and on freshly excised human breast fibroadenoma, demonstrating a resolution of up to 15–25 µm and a field of view of up to 7 mm. Our method is open source and readily adaptable to other imaging modalities, such as ultrasonography and confocal microscopy. PMID:28250098

  5. Remotely deployable aerial inspection using tactile sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLeod, C. N.; Cao, J.; Pierce, S. G.

    For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment,more » resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.« less

  6. An Investigation of the Visual and Tactile Spatial Reasoning Abilities of the Hearing Impaired/Deaf Student.

    ERIC Educational Resources Information Center

    Hauptman, Anna R.

    Two experiments involving 42 students from the Model Secondary School for the Deaf investigated both the visual and tactile components in the processing of spatial information. Test measures used were the Figures Rotations Test, Group Embedded Figures Test, and Tactile Rotations Test. The study suggested that spatial reasoning is a determining…

  7. Participation of Parents in the Early Exploration of Tactile Graphics by Children Who Are Visually Impaired

    ERIC Educational Resources Information Center

    Ryles, Ruby; Bell, Edward

    2009-01-01

    Seventy-three children with visual impairments aged 2-10 and their parents participated in a project that examined the children's interest in and exploration of tactile graphics. The parents reported that the children's interest in and conceptual understanding of the project's tactile workbook were high and that the children explored the…

  8. A Meta-Analytic Review of Tactile-Cued Self-Monitoring Interventions Used by Students in Educational Settings

    ERIC Educational Resources Information Center

    McDougall, Dennis; Ornelles, Cecily; Mersberg, Kawika; Amona, Kekama

    2015-01-01

    In this meta-analytic review, we critically evaluate procedures and outcomes from nine intervention studies in which students used tactile-cued self-monitoring in educational settings. Findings suggest that most tactile-cued self-monitoring interventions have moderate to strong effects, have emerged only recently, and have not yet achieved the…

  9. Stimulus meanings alter illusory self-motion (vection)--experimental examination of the train illusion.

    PubMed

    Seno, Takeharu; Fukuda, Haruaki

    2012-01-01

    Over the last 100 years, numerous studies have examined the effective visual stimulus properties for inducing illusory self-motion (known as vection). This vection is often experienced more strongly in daily life than under controlled experimental conditions. One well-known example of vection in real life is the so-called 'train illusion'. In the present study, we showed that this train illusion can also be generated in the laboratory using virtual computer graphics-based motion stimuli. We also demonstrated that this vection can be modified by altering the meaning of the visual stimuli (i.e., top down effects). Importantly, we show that the semantic meaning of a stimulus can inhibit or facilitate vection, even when there is no physical change to the stimulus.

  10. Discrimination of Dynamic Tactile Contact by Temporally Precise Event Sensing in Spiking Neuromorphic Networks

    PubMed Central

    Lee, Wang Wei; Kukreja, Sunil L.; Thakor, Nitish V.

    2017-01-01

    This paper presents a neuromorphic tactile encoding methodology that utilizes a temporally precise event-based representation of sensory signals. We introduce a novel concept where touch signals are characterized as patterns of millisecond precise binary events to denote pressure changes. This approach is amenable to a sparse signal representation and enables the extraction of relevant features from thousands of sensing elements with sub-millisecond temporal precision. We also proposed measures adopted from computational neuroscience to study the information content within the spiking representations of artificial tactile signals. Implemented on a state-of-the-art 4096 element tactile sensor array with 5.2 kHz sampling frequency, we demonstrate the classification of transient impact events while utilizing 20 times less communication bandwidth compared to frame based representations. Spiking sensor responses to a large library of contact conditions were also synthesized using finite element simulations, illustrating an 8-fold improvement in information content and a 4-fold reduction in classification latency when millisecond-precise temporal structures are available. Our research represents a significant advance, demonstrating that a neuromorphic spatiotemporal representation of touch is well suited to rapid identification of critical contact events, making it suitable for dynamic tactile sensing in robotic and prosthetic applications. PMID:28197065

  11. Tactile acuity and lumbopelvic motor control in patients with back pain and healthy controls.

    PubMed

    Luomajoki, H; Moseley, G L

    2011-04-01

    Voluntary lumbopelvic control is compromised in patients with back pain. Loss of proprioceptive acuity is one contributor to decreased control. Several reasons for decreased proprioceptive acuity have been proposed, but the integrity of cortical body maps has been overlooked. We investigated whether tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to lumbopelvic control in people with back pain. Forty-five patients with back pain and 45 age- and sex-matched healthy controls participated in this cross-sectional study. Tactile acuity at the back was assessed using two-point discrimination (TPD) threshold in vertical and horizontal directions. Voluntary motor control was assessed using an established battery of clinical tests. Patients performed worse on the voluntary lumbopelvic tasks than healthy controls did (p<0.001). TPD threshold was larger in patients (mean (SD)=61 (13) mm) than in healthy controls (44 (10) mm). Moreover, larger TPD threshold was positively related to worse performance on the voluntary lumbopelvic tasks (Pearson's r=0.49; p<0.001). Tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to voluntary lumbopelvic control. This relationship raises the possibility that the former contributes to the latter, in which case training tactile acuity may aid recovery and assist in achieving normal motor performance after back injury.

  12. Functional consequences of experience-dependent plasticity on tactile perception following perceptual learning.

    PubMed

    Trzcinski, Natalie K; Gomez-Ramirez, Manuel; Hsiao, Steven S

    2016-09-01

    Continuous training enhances perceptual discrimination and promotes neural changes in areas encoding the experienced stimuli. This type of experience-dependent plasticity has been demonstrated in several sensory and motor systems. Particularly, non-human primates trained to detect consecutive tactile bar indentations across multiple digits showed expanded excitatory receptive fields (RFs) in somatosensory cortex. However, the perceptual implications of these anatomical changes remain undetermined. Here, we trained human participants for 9 days on a tactile task that promoted expansion of multi-digit RFs. Participants were required to detect consecutive indentations of bar stimuli spanning multiple digits. Throughout the training regime we tracked participants' discrimination thresholds on spatial (grating orientation) and temporal tasks on the trained and untrained hands in separate sessions. We hypothesized that training on the multi-digit task would decrease perceptual thresholds on tasks that require stimulus processing across multiple digits, while also increasing thresholds on tasks requiring discrimination on single digits. We observed an increase in orientation thresholds on a single digit. Importantly, this effect was selective for the stimulus orientation and hand used during multi-digit training. We also found that temporal acuity between digits improved across trained digits, suggesting that discriminating the temporal order of multi-digit stimuli can transfer to temporal discrimination of other tactile stimuli. These results suggest that experience-dependent plasticity following perceptual learning improves and interferes with tactile abilities in manners predictive of the task and stimulus features used during training. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  13. Numbness in clinical and experimental pain--a cross-sectional study exploring the mechanisms of reduced tactile function.

    PubMed

    Geber, Christian; Magerl, Walter; Fondel, Ricarda; Fechir, Marcel; Rolke, Roman; Vogt, Thomas; Treede, Rolf-Detlef; Birklein, Frank

    2008-09-30

    Pain patients often report distinct numbness of the painful skin although no structural peripheral or central nerve lesion is obvious. In this cross-sectional study we assessed the reduction of tactile function and studied underlying mechanisms in patients with chronic pain and in healthy participants exposed to phasic and tonic experimental nociceptive stimulation. Mechanical detection (MDT) and pain thresholds (MPT) were assessed in the painful area and the non-painful contralateral side in 10 patients with unilateral musculoskeletal pain. Additionally, 10 healthy participants were exposed to nociceptive stimulation applied to the volar forearms (capsaicin; electrical stimulation, twice each). Areas of tactile hypaesthesia and mechanical hyperalgesia were assessed. MDT and MPT were quantified adjacent to the stimulation site. Tactile hypaesthesia in pain patients and in experimental pain (MDT-z-scores: -0.66+/-0.30 and -0.42+/-0.15, respectively, both p<0.01) was paralleled by mechanical hyperalgesia (MPT-z-scores: +0.51+/-0.27, p<0.05; and +0.48+/-0.10, p<0.001). However, hypaesthesia and hyperalgesia were not correlated. Although 9 patients reported numbness, only 3 of them were able to delineate circumscript areas of tactile hypaesthesia. In experimental pain, the area of tactile hypaesthesia could be mapped in 31/40 experiments (78%). Irrespective of the mode of nociceptive stimulation (phasic vs. tonic) tactile hypaesthesia and hyperalgesia developed with a similar time course and disappeared within approximately 1 day. Hypaesthesia (numbness) often encountered in clinical pain can be reproduced by experimental nociceptive stimulation. The time course of effects suggests a mechanism involving central plasticity.

  14. Cortical and thalamic contributions to response dynamics across layers of the primary somatosensory cortex during tactile discrimination

    PubMed Central

    Pais-Vieira, Miguel; Kunicki, Carolina; Tseng, Po-He; Martin, Joel; Lebedev, Mikhail

    2015-01-01

    Tactile information processing in the rodent primary somatosensory cortex (S1) is layer specific and involves modulations from both thalamocortical and cortico-cortical loops. However, the extent to which these loops influence the dynamics of the primary somatosensory cortex while animals execute tactile discrimination remains largely unknown. Here, we describe neural dynamics of S1 layers across the multiple epochs defining a tactile discrimination task. We observed that neuronal ensembles within different layers of the S1 cortex exhibited significantly distinct neurophysiological properties, which constantly changed across the behavioral states that defined a tactile discrimination. Neural dynamics present in supragranular and granular layers generally matched the patterns observed in the ventral posterior medial nucleus of the thalamus (VPM), whereas the neural dynamics recorded from infragranular layers generally matched the patterns from the posterior nucleus of the thalamus (POM). Selective inactivation of contralateral S1 specifically switched infragranular neural dynamics from POM-like to those resembling VPM neurons. Meanwhile, ipsilateral M1 inactivation profoundly modulated the firing suppression observed in infragranular layers. This latter effect was counterbalanced by contralateral S1 block. Tactile stimulus encoding was layer specific and selectively affected by M1 or contralateral S1 inactivation. Lastly, causal information transfer occurred between all neurons in all S1 layers but was maximal from infragranular to the granular layer. These results suggest that tactile information processing in the S1 of awake behaving rodents is layer specific and state dependent and that its dynamics depend on the asynchronous convergence of modulations originating from ipsilateral M1 and contralateral S1. PMID:26180115

  15. Evaluation of the MEMS based portable respiratory training system with a tactile sensor for respiratory-gated radiotherapy

    NASA Astrophysics Data System (ADS)

    Moon, Sun Young; Yoon, Myonggeun; Chung, Mijoo; Chung, Weon Kuu; Kim, Dong Wook

    2017-10-01

    In respiratory-gated radiotherapy, it is important to maintain the regular respiratory cycles of patients. If patients undergo respiration training, their regular breathing pattern is affected. Therefore, we developed a respiratory training system based on a micro electromechanical system (MEMS) and evaluated the feasibility of the MEMS in radiotherapy. By comparing the measured signal before and after radiation exposure, we confirmed the effects of radiation. By evaluating the period of the electric signal emitted by a tactile sensor and its constancy, the performance of the tactile sensor was confirmed. Moreover, by comparing the delay between the motion of the MEMS and the electric signal from the tactile sensor, we confirmed the reaction time of the tactile sensor. The results showed that a baseline shift occurred for an accumulated dose of 400 Gy in the sensor, and both the amplitude and period changed. The period of the signal released by the tactile sensor was 5.39 and its standard deviation was 0.06. Considering the errors from the motion phantom, a standard deviation of 0.06 was desirable. The delay time was within 0.5 s and not distinguishable by a patient. We confirmed the performance of the MEMS and concluded that MEMS could be applied to patients for respiratory-gated radiotherapy.

  16. Task demands affect spatial reference frame weighting during tactile localization in sighted and congenitally blind adults

    PubMed Central

    Schubert, Jonathan T. W.; Badde, Stephanie; Röder, Brigitte

    2017-01-01

    Task demands modulate tactile localization in sighted humans, presumably through weight adjustments in the spatial integration of anatomical, skin-based, and external, posture-based information. In contrast, previous studies have suggested that congenitally blind humans, by default, refrain from automatic spatial integration and localize touch using only skin-based information. Here, sighted and congenitally blind participants localized tactile targets on the palm or back of one hand, while ignoring simultaneous tactile distractors at congruent or incongruent locations on the other hand. We probed the interplay of anatomical and external location codes for spatial congruency effects by varying hand posture: the palms either both faced down, or one faced down and one up. In the latter posture, externally congruent target and distractor locations were anatomically incongruent and vice versa. Target locations had to be reported either anatomically (“palm” or “back” of the hand), or externally (“up” or “down” in space). Under anatomical instructions, performance was more accurate for anatomically congruent than incongruent target-distractor pairs. In contrast, under external instructions, performance was more accurate for externally congruent than incongruent pairs. These modulations were evident in sighted and blind individuals. Notably, distractor effects were overall far smaller in blind than in sighted participants, despite comparable target-distractor identification performance. Thus, the absence of developmental vision seems to be associated with an increased ability to focus tactile attention towards a non-spatially defined target. Nevertheless, that blind individuals exhibited effects of hand posture and task instructions in their congruency effects suggests that, like the sighted, they automatically integrate anatomical and external information during tactile localization. Moreover, spatial integration in tactile processing is, thus, flexibly

  17. How Do Batters Use Visual, Auditory, and Tactile Information about the Success of a Baseball Swing?

    ERIC Educational Resources Information Center

    Gray, Rob

    2009-01-01

    Bat/ball contact produces visual (the ball leaving the bat), auditory (the "crack" of the bat), and tactile (bat vibration) feedback about the success of the swing. We used a batting simulation to investigate how college baseball players use visual, tactile, and auditory feedback. In Experiment 1, swing accuracy (i.e., the lateral separation…

  18. The display of tactile information

    NASA Technical Reports Server (NTRS)

    Sherrick, Carl E.

    1991-01-01

    There are a number of examples of natural tactile displays that can five us some insights about the solid geometry of touch, and recent experimental work on the subject has extended our thinking considerably. The concern of here is, however, more with synthetic or artificial displays for the production of a virtual environment. Features of synthetic displays that have enjoyed some success in one of the following two enterprises are discussed: the study of the spatio-temporal dimensions of stimuli that afford accurate and rapid processing of environmental information, or the use of displays in the design of sensory aids for disabled persons.

  19. Durable Tactile Glove for Human or Robot Hand

    NASA Technical Reports Server (NTRS)

    Butzer, Melissa; Diftler, Myron A.; Huber, Eric

    2010-01-01

    A glove containing force sensors has been built as a prototype of tactile sensor arrays to be worn on human hands and anthropomorphic robot hands. The force sensors of this glove are mounted inside, in protective pockets; as a result of this and other design features, the present glove is more durable than earlier models.

  20. An adenosine kinase inhibitor attenuates tactile allodynia in a rat model of diabetic neuropathic pain.

    PubMed

    Lynch, J J; Jarvis, M F; Kowaluk, E A

    1999-01-08

    The present study was conducted to characterize the development of tactile allodynia in the streptozotocin-induced rat model of diabetes, and to evaluate the antinociceptive effects of systemically administered morphine and the adenosine kinase inhibitor, 5'-deoxy-5-iodotubercidin (5'd-5IT) in this model. Rats were injected with 75 mg/kg streptozotocin (i.p.), and blood glucose levels were determined 3-4 weeks later. Diabetic (blood glucose levels > or = 250 mg/dl) and vehicle-injected rats were examined weekly for the development of tactile allodynia by measuring the threshold for hind paw withdrawal using von Frey hairs. Withdrawal thresholds were reduced to 6.8+/-0.6 g (mean+/-S.E.M.) in approximately one-third of streptozotocin-treated rats 7 weeks after streptozotocin treatment as compared to control thresholds (13.2+/-0.1 g), and this allodynia persisted for at least an additional 7 weeks. In additional experiments, morphine sulfate (5-21 micromol/kg, i.p.) produced dose-dependent antinociceptive effects on tactile allodynia for up to 2 h post-dosing. The adenosine kinase inhibitor, 5'd-5IT (2.5 and 5 micromol/kg, i.p.) also dose-dependently attenuated tactile allodynia. Pretreatment with the opioid receptor antagonist, naloxone (27 micromol/kg, i.p.) or the non-selective adenosine receptor antagonist, theophylline (111 micromol/kg, i.p.) significantly diminished the anti-allodynic effects of morphine and 5'd-5IT, respectively. The present study demonstrates that the potent and selective adenosine kinase inhibitor, 5'd-5IT, is equally effective as morphine in blocking tactile allodynia in this model.

  1. Toward a tactile language for human-robot interaction: two studies of tacton learning and performance.

    PubMed

    Barber, Daniel J; Reinerman-Jones, Lauren E; Matthews, Gerald

    2015-05-01

    Two experiments were performed to investigate the feasibility for robot-to-human communication of a tactile language using a lexicon of standardized tactons (tactile icons) within a sentence. Improvements in autonomous systems technology and a growing demand within military operations are spurring interest in communication via vibrotactile displays. Tactile communication may become an important element of human-robot interaction (HRI), but it requires the development of messaging capabilities approaching the communication power of the speech and visual signals used in the military. In Experiment 1 (N = 38), we trained participants to identify sets of directional, dynamic, and static tactons and tested performance and workload following training. In Experiment 2 (N = 76), we introduced an extended training procedure and tested participants' ability to correctly identify two-tacton phrases. We also investigated the impact of multitasking on performance and workload. Individual difference factors were assessed. Experiment 1 showed that participants found dynamic and static tactons difficult to learn, but the enhanced training procedure in Experiment 2 produced competency in performance for all tacton categories. Participants in the latter study also performed well on two-tacton phrases and when multitasking. However, some deficits in performance and elevation of workload were observed. Spatial ability predicted some aspects of performance in both studies. Participants may be trained to identify both single tactons and tacton phrases, demonstrating the feasibility of developing a tactile language for HRI. Tactile communication may be incorporated into multi-modal communication systems for HRI. It also has potential for human-human communication in challenging environments. © 2014, Human Factors and Ergonomics Society.

  2. Contact geometry and mechanics predict friction forces during tactile surface exploration.

    PubMed

    Janko, Marco; Wiertlewski, Michael; Visell, Yon

    2018-03-20

    When we touch an object, complex frictional forces are produced, aiding us in perceiving surface features that help to identify the object at hand, and also facilitating grasping and manipulation. However, even during controlled tactile exploration, sliding friction forces fluctuate greatly, and it is unclear how they relate to the surface topography or mechanics of contact with the finger. We investigated the sliding contact between the finger and different relief surfaces, using high-speed video and force measurements. Informed by these experiments, we developed a friction force model that accounts for surface shape and contact mechanical effects, and is able to predict sliding friction forces for different surfaces and exploration speeds. We also observed that local regions of disconnection between the finger and surface develop near high relief features, due to the stiffness of the finger tissues. Every tested surface had regions that were never contacted by the finger; we refer to these as "tactile blind spots". The results elucidate friction force production during tactile exploration, may aid efforts to connect sensory and motor function of the hand to properties of touched objects, and provide crucial knowledge to inform the rendering of realistic experiences of touch contact in virtual reality.

  3. Sensory Responsiveness and the Effects of Equal Subjective Rewards on Tactile Learning and Memory of Honeybees

    ERIC Educational Resources Information Center

    Scheiner, Ricarda; Kuritz-Kaiser, Anthea; Menzel, Randolf; Erber, Joachim

    2005-01-01

    In tactile learning, sucrose is the unconditioned stimulus and reward, which is usually applied to the antenna to elicit proboscis extension and which the bee can drink when it is subsequently applied to the extended proboscis. The conditioned stimulus is a tactile object that the bee can scan with its antennae. In this paper we describe the…

  4. Electrical Signals in Prayer Plants (Marantaceae)? Insights into the Trigger Mechanism of the Explosive Style Movement

    PubMed Central

    Jerominek, Markus; Claßen-Bockhoff, Regine

    2015-01-01

    The explosive pollination mechanism of the prayer plants (Marantaceae) is unique among plants. After a tactile stimulus by a pollinator, the style curls up rapidly and mediates pollen exchange. It is still under discussion whether this explosive movement is released electrophysiologically, i.e. by a change in the membrane potential (as in Venus flytrap), or purely mechanically. In the present study, electrophysiological experiments are conducted to clarify the mechanism. Artificial release experiments (chemical and electrical) and electrophysiological measurements were conducted with two phylogenetically distant species, Goeppertia bachemiana (E. Morren) Borchs. & S. Suárez and Donax canniformis (G. Forst.) K. Schum. Electric responses recorded after style release by extracellular measurements are characterised as variation potentials due to their long repolarization phase and lack of self-perpetuation. In both species, chemical and electric stimulations do not release the style movement. It is concluded that the style movement in Marantaceae is released mechanically by relieving the tissue pressure. Accordingly, the variation potential is an effect of the movement and not its cause. The study exemplarily shows that fast movements in plants are not necessarily initiated by electric changes of the membrane as known from the Venus flytrap. PMID:25997015

  5. Electrical signals in prayer plants (marantaceae)? Insights into the trigger mechanism of the explosive style movement.

    PubMed

    Jerominek, Markus; Claßen-Bockhoff, Regine

    2015-01-01

    The explosive pollination mechanism of the prayer plants (Marantaceae) is unique among plants. After a tactile stimulus by a pollinator, the style curls up rapidly and mediates pollen exchange. It is still under discussion whether this explosive movement is released electrophysiologically, i.e. by a change in the membrane potential (as in Venus flytrap), or purely mechanically. In the present study, electrophysiological experiments are conducted to clarify the mechanism. Artificial release experiments (chemical and electrical) and electrophysiological measurements were conducted with two phylogenetically distant species, Goeppertia bachemiana (E. Morren) Borchs. & S. Suárez and Donax canniformis (G. Forst.) K. Schum. Electric responses recorded after style release by extracellular measurements are characterised as variation potentials due to their long repolarization phase and lack of self-perpetuation. In both species, chemical and electric stimulations do not release the style movement. It is concluded that the style movement in Marantaceae is released mechanically by relieving the tissue pressure. Accordingly, the variation potential is an effect of the movement and not its cause. The study exemplarily shows that fast movements in plants are not necessarily initiated by electric changes of the membrane as known from the Venus flytrap.

  6. [A comparison of time resolution among auditory, tactile and promontory electrical stimulation--superiority of cochlear implants as human communication aids].

    PubMed

    Matsushima, J; Kumagai, M; Harada, C; Takahashi, K; Inuyama, Y; Ifukube, T

    1992-09-01

    Our previous reports showed that second formant information, using a speech coding method, could be transmitted through an electrode on the promontory. However, second formant information can also be transmitted by tactile stimulation. Therefore, to find out whether electrical stimulation of the auditory nerve would be superior to tactile stimulation for our speech coding method, the time resolutions of the two modes of stimulation were compared. The results showed that the time resolution of electrical promontory stimulation was three times better than the time resolution of tactile stimulation of the finger. This indicates that electrical stimulation of the auditory nerve is much better for our speech coding method than tactile stimulation of the finger.

  7. Connections between intraparietal sulcus and a sensorimotor network underpin sustained tactile attention.

    PubMed

    Goltz, Dominique; Gundlach, Christopher; Nierhaus, Till; Villringer, Arno; Müller, Matthias; Pleger, Burkhard

    2015-05-20

    Previous studies on sustained tactile attention draw conclusions about underlying cortical networks by averaging over experimental conditions without considering attentional variance in single trials. This may have formed an imprecise picture of brain processes underpinning sustained tactile attention. In the present study, we simultaneously recorded EEG-fMRI and used modulations of steady-state somatosensory evoked potentials (SSSEPs) as a measure of attentional trial-by-trial variability. Therefore, frequency-tagged streams of vibrotactile stimulations were simultaneously presented to both index fingers. Human participants were cued to sustain attention to either the left or right finger stimulation and to press a button whenever they perceived a target pulse embedded in the to-be-attended stream. In-line with previous studies, a classical general linear model (GLM) analysis based on cued attention conditions revealed increased activity mainly in somatosensory and cerebellar regions. Yet, parametric modeling of the BOLD response using simultaneously recorded SSSEPs as a marker of attentional trial-by-trial variability quarried the intraparietal sulcus (IPS). The IPS in turn showed enhanced functional connectivity to a modality-unspecific attention network. However, this was only revealed on the basis of cued attention conditions in the classical GLM. By considering attentional variability as captured by SSSEPs, the IPS showed increased connectivity to a sensorimotor network, underpinning attentional selection processes between competing tactile stimuli and action choices (press a button or not). Thus, the current findings highlight the potential value by considering attentional variations in single trials and extend previous knowledge on the role of the IPS in tactile attention. Copyright © 2015 the authors 0270-6474/15/357938-12$15.00/0.

  8. Multisensory Motion Perception in 3–4 Month-Old Infants

    PubMed Central

    Nava, Elena; Grassi, Massimo; Brenna, Viola; Croci, Emanuela; Turati, Chiara

    2017-01-01

    Human infants begin very early in life to take advantage of multisensory information by extracting the invariant amodal information that is conveyed redundantly by multiple senses. Here we addressed the question as to whether infants can bind multisensory moving stimuli, and whether this occurs even if the motion produced by the stimuli is only illusory. Three- to 4-month-old infants were presented with two bimodal pairings: visuo-tactile and audio-visual. Visuo-tactile pairings consisted of apparently vertically moving bars (the Barber Pole illusion) moving in either the same or opposite direction with a concurrent tactile stimulus consisting of strokes given on the infant’s back. Audio-visual pairings consisted of the Barber Pole illusion in its visual and auditory version, the latter giving the impression of a continuous rising or ascending pitch. We found that infants were able to discriminate congruently (same direction) vs. incongruently moving (opposite direction) pairs irrespective of modality (Experiment 1). Importantly, we also found that congruently moving visuo-tactile and audio-visual stimuli were preferred over incongruently moving bimodal stimuli (Experiment 2). Our findings suggest that very young infants are able to extract motion as amodal component and use it to match stimuli that only apparently move in the same direction. PMID:29187829

  9. Flexible Tactile Sensing Based on Piezoresistive Composites: A Review

    PubMed Central

    Stassi, Stefano; Cauda, Valentina; Canavese, Giancarlo; Pirri, Candido Fabrizio

    2014-01-01

    The large expansion of the robotic field in the last decades has created a growing interest in the research and development of tactile sensing solutions for robot hand and body integration. Piezoresistive composites are one of the most widely employed materials for this purpose, combining simple and low cost preparation with high flexibility and conformability to surfaces, low power consumption, and the use of simple read-out electronics. This work provides a review on the different type of composite materials, classified according to the conduction mechanism and analyzing the physics behind it. In particular piezoresistors, strain gauges, percolative and quantum tunnelling devices are reviewed here, with a perspective overview on the most used filler types and polymeric matrices. A description of the state-of-the-art of the tactile sensor solutions from the point of view of the architecture, the design and the performance is also reviewed, with a perspective outlook on the main promising applications. PMID:24638126

  10. Design and simulation of a tactile display based on a CMUT array

    NASA Astrophysics Data System (ADS)

    Chouvardas, Vasilios G.; Hatalis, Miltiadis K.; Miliou, Amalia N.

    2012-10-01

    In this article, we present the design of a tactile display based on a CMUT-phased array. The array implements a 'pixel' of the display and is used to focus airborne ultrasound energy on the skin surface. The pressure field, generated by the focused ultrasound waves, is used to excite the mechanoreceptors under the skin and transmit tactile information. The results of Finite Element Analysis (FEA) of the Capacitive Micromachined Ultrasonic Transducer (CMUT) and the CMUT-phased array for ultrasound emission are presented. The 3D models of the device and the array were developed using a commercial FEA package. Modelling and simulations were performed using the parameters from the POLYMUMPS surface micromachining technology from MEMSCAP. During the analysis of the phased array, several parameters were studied in order to determine their importance in the design of the tactile display. The output of the array is compared with the acoustic intensity thresholds in order to prove the feasibility of the design. Taking into account the density of the mechanoreceptors in the skin, we conclude that there should be at least one receptor under the excitation area formed on the skin.

  11. The use of a tactile interface to convey position and motion perceptions

    NASA Technical Reports Server (NTRS)

    Rupert, A. H.; Guedry, F. E.; Reschke, M. F.

    1994-01-01

    Under normal terrestrial conditions, perception of position and motion is determined by central nervous system integration of concordant and redundant information from multiple sensory channels (somatosensory, vestibular, visual), which collectively yield vertical perceptions. In the acceleration environment experienced by the pilots, the somatosensory and vestibular sensors frequently present false information concerning the direction of gravity. When presented with conflicting sensory information, it is normal for pilots to experience episodes of disorientation. We have developed a tactile interface that obtains vertical roll and pitch information from a gyro-stabilized attitude indicator and maps this information in a one-to-one correspondence onto the torso of the body using a matrix of vibrotactors. This enables the pilot to continuously maintain an awareness of aircraft attitude without reference to visual cues, utilizing a sensory channel that normally operates at the subconscious level. Although initially developed to improve pilot spatial awareness, this device has obvious applications to 1) simulation and training, 2) nonvisual tracking of targets, which can reduce the need for pilots to make head movements in the high-G environment of aerial combat, and 3) orientation in environments with minimal somatosensory cues (e.g., underwater) or gravitational cues (e.g., space).

  12. Tactile sensor of hardness recognition based on magnetic anomaly detection

    NASA Astrophysics Data System (ADS)

    Xue, Lingyun; Zhang, Dongfang; Chen, Qingguang; Rao, Huanle; Xu, Ping

    2018-03-01

    Hardness, as one kind of tactile sensing, plays an important role in the field of intelligent robot application such as gripping, agricultural harvesting, prosthetic hand and so on. Recently, with the rapid development of magnetic field sensing technology with high performance, a number of magnetic sensors have been developed for intelligent application. The tunnel Magnetoresistance(TMR) based on magnetoresistance principal works as the sensitive element to detect the magnetic field and it has proven its excellent ability of weak magnetic detection. In the paper, a new method based on magnetic anomaly detection was proposed to detect the hardness in the tactile way. The sensor is composed of elastic body, ferrous probe, TMR element, permanent magnet. When the elastic body embedded with ferrous probe touches the object under the certain size of force, deformation of elastic body will produce. Correspondingly, the ferrous probe will be forced to displace and the background magnetic field will be distorted. The distorted magnetic field was detected by TMR elements and the output signal at different time can be sampled. The slope of magnetic signal with the sampling time is different for object with different hardness. The result indicated that the magnetic anomaly sensor can recognize the hardness rapidly within 150ms after the tactile moment. The hardness sensor based on magnetic anomaly detection principal proposed in the paper has the advantages of simple structure, low cost, rapid response and it has shown great application potential in the field of intelligent robot.

  13. The Tactile Vision Substitution System: Applications in Education and Employment

    ERIC Educational Resources Information Center

    Scadden, Lawrence A.

    1974-01-01

    The Tactile Vision Substitution System converts the visual image from a narrow-angle television camera to a tactual image on a 5-inch square, 100-point display of vibrators placed against the abdomen of the blind person. (Author)

  14. Aristotle's illusion reveals interdigit functional somatosensory alterations in focal hand dystonia.

    PubMed

    Tinazzi, Michele; Marotta, Angela; Fasano, Alfonso; Bove, Francesco; Bentivoglio, Anna Rita; Squintani, Giovanna; Pozzer, Lara; Fiorio, Mirta

    2013-03-01

    In focal hand dystonia, the cortical somatosensory representation of the fingers is abnormal, with overlapping receptive fields and reduced interdigit separation. These abnormalities are associated with deficits in sensory perception, as previously demonstrated by applying tactile stimuli to one finger at a time. What is still unknown is whether the sensory deficits can be observed when tactile perception involves more than one finger. To address this issue, we applied 'Aristotle's illusion' to 15 patients with focal hand dystonia, 15 patients with dystonia not affecting the hand (blepharospasm and cervical dystonia) and 15 healthy control subjects. In this illusion, one object touching the contact point of two crossed fingertips is perceived as two objects by a blindfolded subject. The same object placed between two parallel fingertips is correctly perceived as one. The illusory doubling sensation is because of the fact that the contact point between the crossed fingers consists of non-adjacent and functionally unrelated skin regions, which usually send sensory signals to separate spots in the somatosensory cortex. In our study, participants were touched by one sphere between the second-third digits, the second-fourth digits and the fourth-fifth digits of both hands, either in crossed or in parallel position, and had to refer whether they felt one or two stimuli. The percentage of 'two stimuli' responses was an index of the illusory doubling. Both healthy control subjects and dystonic patients presented Aristotle's illusion when the fingers were crossed. However, patients with focal hand dystonia presented a significant reduction of the illusion when the sphere was placed between the crossed fourth and fifth digits of the affected hand. This reduction correlated with the severity of motor disease at the fingers. Similar findings were not observed in non-hand dystonia and control groups. The reduction of Aristotle's illusion in non-affected fingers and its

  15. A Test of Tactile Concentration and Short-Term Memory.

    ERIC Educational Resources Information Center

    Kainthola, S. D.; Singh, T. B.

    1992-01-01

    Twenty students and 45 adults with visual impairments or blindness were administered a test of tactile concentration and short-term memory involving the reproduction of the order of finger stimulation using the Finger Knocking Box. Reliability and validity scores indicated encouraging results with use of the instrument. (JDD)

  16. Decline of human tactile angle discrimination in patients with mild cognitive impairment and Alzheimer's disease.

    PubMed

    Yang, Jiajia; Ogasa, Takashi; Ohta, Yasuyuki; Abe, Koji; Wu, Jinglong

    2010-01-01

    There is a need to differentiate between patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD) from normal-aged controls (NC) in the field of clinical drug discovery. In this study, we developed a tactile angle discrimination system and examined whether the ability to discriminate tactile angle differed between patients with MCI and AD and the NC group. Thirty-seven subjects were divided into three groups: NC individuals (n=14); MCI patients (n=10); and probable AD patients (n=13). All subjects were asked to differentiate the relative sizes of the reference angle (60°) and one of eight comparison angles by passive touch. The accuracy of angle discrimination was measured and the discrimination threshold was calculated. We discovered that there were significant differences in the angle discrimination thresholds of AD patients compared to the NC group. Interestingly, we also found that ability to discriminate tactile angle of MCI patients were significantly lower than that of the NC group. This is the first study to report that patients with MCI and AD have substantial performance deficits in tactile angle discrimination compared to the NC individuals. This finding may provide a monitor and therapeutic approach in AD diagnosis and treatment.

  17. A Finger-Shaped Tactile Sensor for Fabric Surfaces Evaluation by 2-Dimensional Active Sliding Touch

    PubMed Central

    Hu, Haihua; Han, Yezhen; Song, Aiguo; Chen, Shanguang; Wang, Chunhui; Wang, Zheng

    2014-01-01

    Sliding tactile perception is a basic function for human beings to determine the mechanical properties of object surfaces and recognize materials. Imitating this process, this paper proposes a novel finger-shaped tactile sensor based on a thin piezoelectric polyvinylidene fluoride (PVDF) film for surface texture measurement. A parallelogram mechanism is designed to ensure that the sensor applies a constant contact force perpendicular to the object surface, and a 2-dimensional movable mechanical structure is utilized to generate the relative motion at a certain speed between the sensor and the object surface. By controlling the 2-dimensional motion of the finger-shaped sensor along the object surface, small height/depth variation of surface texture changes the output charge of PVDF film then surface texture can be measured. In this paper, the finger-shaped tactile sensor is used to evaluate and classify five different kinds of linen. Fast Fourier Transformation (FFT) is utilized to get original attribute data of surface in the frequency domain, and principal component analysis (PCA) is used to compress the attribute data and extract feature information. Finally, low dimensional features are classified by Support Vector Machine (SVM). The experimental results show that this finger-shaped tactile sensor is effective and high accurate for discriminating the five textures. PMID:24618775

  18. A Novel Tactile Sensor with Electromagnetic Induction and Its Application on Stick-Slip Interaction Detection

    PubMed Central

    Liu, Yanjie; Han, Haijun; Liu, Tao; Yi, Jingang; Li, Qingguo; Inoue, Yoshio

    2016-01-01

    Real-time detection of contact states, such as stick-slip interaction between a robot and an object on its end effector, is crucial for the robot to grasp and manipulate the object steadily. This paper presents a novel tactile sensor based on electromagnetic induction and its application on stick-slip interaction. An equivalent cantilever-beam model of the tactile sensor was built and capable of constructing the relationship between the sensor output and the friction applied on the sensor. With the tactile sensor, a new method to detect stick-slip interaction on the contact surface between the object and the sensor is proposed based on the characteristics of friction change. Furthermore, a prototype was developed for a typical application, stable wafer transferring on a wafer transfer robot, by considering the spatial magnetic field distribution and the sensor size according to the requirements of wafer transfer. The experimental results validate the sensing mechanism of the tactile sensor and verify its feasibility of detecting stick-slip on the contact surface between the wafer and the sensor. The sensing mechanism also provides a new approach to detect the contact state on the soft-rigid surface in other robot-environment interaction systems. PMID:27023545

  19. A finger-shaped tactile sensor for fabric surfaces evaluation by 2-dimensional active sliding touch.

    PubMed

    Hu, Haihua; Han, Yezhen; Song, Aiguo; Chen, Shanguang; Wang, Chunhui; Wang, Zheng

    2014-03-11

    Sliding tactile perception is a basic function for human beings to determine the mechanical properties of object surfaces and recognize materials. Imitating this process, this paper proposes a novel finger-shaped tactile sensor based on a thin piezoelectric polyvinylidene fluoride (PVDF) film for surface texture measurement. A parallelogram mechanism is designed to ensure that the sensor applies a constant contact force perpendicular to the object surface, and a 2-dimensional movable mechanical structure is utilized to generate the relative motion at a certain speed between the sensor and the object surface. By controlling the 2-dimensional motion of the finger-shaped sensor along the object surface, small height/depth variation of surface texture changes the output charge of PVDF film then surface texture can be measured. In this paper, the finger-shaped tactile sensor is used to evaluate and classify five different kinds of linen. Fast Fourier Transformation (FFT) is utilized to get original attribute data of surface in the frequency domain, and principal component analysis (PCA) is used to compress the attribute data and extract feature information. Finally, low dimensional features are classified by Support Vector Machine (SVM). The experimental results show that this finger-shaped tactile sensor is effective and high accurate for discriminating the five textures.

  20. A case of tactile agnosia with a lesion restricted to the post-central gyrus.

    PubMed

    Estañol, Bruno; Baizabal-Carvallo, José Fidel; Sentíes-Madrid, Horacio

    2008-01-01

    Tactile agnosia has been described after lesions of the primary sensory cortex but the exact location and extension of those lesions is not clear. We report the clinical features and imaging findings in a patient with an acute ischemic stroke restricted to the primary sensory area (S1). A 73-year-old man had a sudden onset of a left alien hand, without left hemiparesis. Neurological examination showed intact primary sensory functions, but impaired recognition of shape, size (macrogeometrical) and texture (microgeometrical) of objects; damage confined to the post-central gyrus, sparing the posterior parietal cortex was demonstrated on MRI. An embolic occlusion of the anterior parietal artery was suspected as mechanism of stroke. Tactile agnosia with impaired microgeometrical and macrogeometrical features' recognition can result from a single lesion in the primary sensory cortex (S1) in the right parietal hemisphere, sparing other regions of the cerebral cortex which presumably participate in tactile object recognition.