Sample records for tail vein catheter

  1. Pulmonary vein stenosis following catheter ablation of atrial fibrillation.

    PubMed

    Pürerfellner, Helmut; Martinek, Martin

    2005-11-01

    This review provides an update on the mechanisms, incidence, and current management of significant pulmonary vein stenosis following catheter ablation of atrial fibrillation. Catheter ablation involving the pulmonary veins and the surrounding left atrial tissue is increasingly used to treat atrial fibrillation. In parallel with the fact that these procedures may cure a substantial proportion of patients, severe complications have been observed. Pulmonary vein stenosis is a new clinical entity produced by radiofrequency energy delivery mainly within or at the orifice of the pulmonary veins. The exact incidence is currently unknown because the diagnosis is dependent on the imaging modality and on the rigor with which patients are followed up. The optimal method for screening patients has not been determined. Stenosis of a pulmonary vein may be assessed by combining anatomic and functional imaging using computed tomographic or magnetic resonance imaging, transesophageal echocardiography, and lung scanning. Symptoms vary considerably and may be misdiagnosed, leading to severe clinical consequences. Current treatment strategies involve pulmonary vein dilatation or stenting; however, the restenosis rate remains high. The long-term outcome in patients with pulmonary vein stenosis is unclear. Strategies under development to prevent pulmonary vein stenosis include alternate energy sources and modified ablation techniques. Pulmonary vein stenosis following catheter ablation is a new clinical entity that has been described in various reports recently. There is much uncertainty with respect to causative factors, incidence, diagnosis, and treatment, and long-term sequelae are unclear.

  2. Modelling catheter-vein biomechanical interactions during an intravenous procedure.

    PubMed

    Weiss, Dar; Gefen, Amit; Einav, Shmuel

    2016-02-01

    A reliable intravenous (IV) access into the upper extremity veins requires the insertion of a temporary short peripheral catheter (SPC). This so common procedure is, however, associated with a risk of developing short peripheral catheter thrombophlebitis (SPCT) which causes distress and potentially prolongs patient hospitalization. We have developed and studied a biomechanical SPC-vein computational model during an IV procedure, and explored the biomechanical effects of repeated IV episodes on onset and reoccurrences of SPCT. The model was used to determine the effects of different insertion techniques as well as inter-patient biological variability on the catheter-vein wall contact pressures and wall deformations. We found that the maximal pressure exerted upon the vein wall was inhomogeneously distributed, and that the bending region was exposed to significantly greater pressures and deformations. The maximal exerted contact pressure on the inner vein's wall was 2938 Pa. The maximal extent of the SPC penetration into the vein wall reached 3.6 μm, which corresponds to approximately 100% of the average height of the inner layer, suggesting local squashing of endothelial cells at the contact site. The modelling describes a potential biomechanical damage pathway that can explain the reoccurrence of SPCT.

  3. Impact of Ultrasound on Short Peripheral Intravenous Catheter Placement on Vein Thrombosis Risk.

    PubMed

    Holder, Max R; Stutzman, Sonja E; Olson, DaiWai M

    Approximately 90% of hospitalized patients have a short peripheral intravenous catheter (SPC) placed. Methods of inserting the catheter have evolved over time and now include the use of ultrasound (US)-guided procedures for placement. Little is known about the impact that US-guided procedures have on the vein. This study compared the rate of venous thrombosis in patients with and without US-guided catheter placement. This prospective, single-blind, observational study assessed for venous thrombosis in 153 veins from 135 patients. Veins were evaluated by a research nurse blinded to the method of placement between 48 and 72 hours after the SPC was placed. The Fisher exact test showed a significant difference between vessel compressibility and catheter insertion method (P = .0012). The proportion of noncompressible veins was significantly greater when US was used in comparison with freehand SPC insertion. The Mantel-Haenszel chi-square value of 10.34 (P = .0013) showed that US insertion technique is associated with a higher likelihood of noncompressible veins. This pilot study provides compelling evidence that the use of US to assist with catheter placement is associated with a higher rate of noncompressible veins at day 2 or 3. Further studies are needed with a larger sample to determine the generalizability of the results from this pilot study.

  4. Mapping and isolation of the pulmonary veins using the PVAC catheter.

    PubMed

    Duytschaever, Mattias; Anne, Wim; Papiashvili, Giorgi; Vandekerckhove, Yves; Tavernier, Rene

    2010-02-01

    We aimed to investigate the feasibility, efficacy, and safety of the pulmonary vein ablation catheter (PVAC) catheter (a novel multielectrode catheter using duty-cycled bipolar and unipolar radiofrequency energy, Medtronic, Minneapolis, MN, USA) to completely isolate the pulmonary veins (PVs). Twenty-seven patients (60 +/- 8 years) with paroxysmal atrial fibrillation (AF) underwent PV isolation with the PVAC catheter. PVAC was used for both mapping and isolation of the PVs (PVAC-guided ablation). After PVAC ablation, presence/absence of PV potentials (PVP) was verified using a conventional circular mapping catheter. In case of residual PVP on the circular catheter, PVAC ablation was continued. After PVAC-guided ablation 99 of 106 PVs (93%) and 21 of 27 patients (78%) were proven to be isolated. Failure to isolate was due to a mapping failure in four right-sided PVs and a true ablation failure in three right-sided PVs. After continued PVAC ablation, 103 of 106 PVs (97%) and 25 of 27 patients (93%) were shown to be isolated. The total procedural time from femoral vein access to complete catheter withdrawal was 176 +/- 25 minutes. The actual dwelling-time of the PVAC within the left atrium was 102 +/- 37 minutes. Esophageal T degrees rise to >38.5 degrees occurred in nine of 19 monitored patients (47%). (1) PVAC-guided ablation (i.e., mapping and ablation with a single catheter) results in isolation of all PVs in 73% of the patients. (2) An additional circular mapping catheter is required to increase complete isolation rate to 93% of the patients. (3) Given the esophageal T degrees rise in almost 50% of patients, safety precautions are needed.

  5. Hemodialysis catheter implantation in the axillary vein by ultrasound guidance versus palpation or anatomical reference

    PubMed Central

    Valencia, Cesar A Restrepo; Villa, Carlos A Buitrago; Cardona, Jose A Chacon

    2013-01-01

    Background We compared the results of four different methods of hemodialysis catheter insertion in the medial segment of the axillary vein: ultrasound guidance, palpation, anatomical reference, and prior transient catheter. Methods All patients that required acute or chronic hemodialysis and for whom it was determined impossible or not recommended either to place a catheter in the internal jugular vein (for instance, those patients with a tracheostomy), or to practice arteriovenous fistula or graft; it was then essential to obtain an alternative vascular access. When the procedure of axillary vein catheter insertion was performed in the Renal Care Facility (RCF), ultrasound guidance was used, but in the intensive care unit (ICU), this resource was unavailable, so the palpation or anatomical reference technique was used. Results Two nephrologists with experience in the technique performed 83 procedures during a period lasting 15 years and 8 months (from January 1997–August 2012): 41 by ultrasound guidance; 19 by anatomical references; 15 by palpation of the contiguous axillary artery; and 8 through a temporary axillary catheter previously placed. The ultrasound-guided patients had fewer punctures than other groups, but the value was not statistically significant. Arterial punctures were infrequent in all techniques. Analyzing all the procedure-related complications, such as hematoma, pneumothorax, brachial-plexus injury, as well as the reasons for catheter removal, no differences were observed among the groups. The functioning time was longer in the ultrasound-guided and previous catheter groups. In 15 years and 8 months of surveillance, no clinical or image evidence for axillary vein stenosis was found. Conclusion The ultrasound guide makes the procedure of inserting catheters in the axillary veins easier, but knowledge of the anatomy of the midaxillary region and the ability to feel the axillary artery pulse (for the palpation method) also allow relatively easy

  6. Comparing Phlebotomy by Tail Tip Amputation, Facial Vein Puncture, and Tail Vein Incision in C57BL/6 Mice by Using Physiologic and Behavioral Metrics of Pain and Distress

    PubMed Central

    Moore, Elizabeth S; Cleland, Thomas A; Williams, Wendy O; Peterson, Christine M; Singh, Bhupinder; Southard, Teresa L; Pasch, Bret; Labitt, Rachael N; Daugherity, Erin K

    2017-01-01

    Tail tip amputation with minimal restraint is not widely used for mouse phlebotomy. In part, this infrequency may reflect policies influenced by tail tip amputation procedures for genotyping, which involve greater handling and tissue removal. To assess tail tip amputation with minimal restraint as a phlebotomy technique, we compared it with 2 more common methods: scruffing with facial vein puncture and lateral tail vein incision with minimal restraint. Blood glucose levels, audible and ultrasonic vocalizations, postphlebotomy activity and grooming behavior, open field and elevated plus maze behaviors, nest-building scores, and histologic changes at the phlebotomy site were evaluated. Mice in the facial vein phlebotomy group produced more audible vocalizations, exhibited lower postphlebotomy activity in the open field, and had more severe histologic changes than did mice in the tail incision and tail tip amputation groups. Facial vein phlebotomy did not affect grooming behavior relative to sham groups, whereas tail vein incision—but not tail tip amputation—increased tail grooming compared with that in control mice. Blood glucose levels, nest-building scores, and elevated plus maze behavior did not differ between groups, and no mice in any group produced ultrasonic vocalizations. Tail tip amputation mice did not perform differently than sham mice in any metric analyzed, indicating that this technique is a potentially superior method of blood collection in mice in terms of animal wellbeing. PMID:28535866

  7. Comparing Phlebotomy by Tail Tip Amputation, Facial Vein Puncture, and Tail Vein Incision in C57BL/6 Mice by Using Physiologic and Behavioral Metrics of Pain and Distress.

    PubMed

    Moore, Elizabeth S; Cleland, Thomas A; Williams, Wendy O; Peterson, Christine M; Singh, Bhupinder; Southard, Teresa L; Pasch, Bret; Labitt, Rachael N; Daugherity, Erin K

    2017-05-01

    Tail tip amputation with minimal restraint is not widely used for mouse phlebotomy. In part, this infrequency may reflect policies influenced by tail tip amputation procedures for genotyping, which involve greater handling and tissue removal. To assess tail tip amputation with minimal restraint as a phlebotomy technique, we compared it with 2 more common methods: scruffing with facial vein puncture and lateral tail vein incision with minimal restraint. Blood glucose levels, audible and ultrasonic vocalizations, postphlebotomy activity and grooming behavior, open field and elevated plus maze behaviors, nest-building scores, and histologic changes at the phlebotomy site were evaluated. Mice in the facial vein phlebotomy group produced more audible vocalizations, exhibited lower postphlebotomy activity in the open field, and had more severe histologic changes than did mice in the tail incision and tail tip amputation groups. Facial vein phlebotomy did not affect grooming behavior relative to sham groups, whereas tail vein incision-but not tail tip amputation-increased tail grooming compared with that in control mice. Blood glucose levels, nest-building scores, and elevated plus maze behavior did not differ between groups, and no mice in any group produced ultrasonic vocalizations. Tail tip amputation mice did not perform differently than sham mice in any metric analyzed, indicating that this technique is a potentially superior method of blood collection in mice in terms of animal wellbeing.

  8. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less

  9. Azygos Vein Dialysis Catheter Placement Using the Translumbar Approach in a Patient with Inferior Vena Cava Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaber, Mohammad R., E-mail: raffatj@msn.co; Thomson, Matthew J.; Smith, Douglas C.

    We describe percutaneous, translumbar placement of a 14-Fr dialysis catheter into an ascending lumbar vein to achieve tip position in an enlarged azygos vein. The patient had thrombosis of all traditional vascular sites, as well as the inferior vena cava. This catheter functioned well for 7 months before fatal catheter-related infection developed.

  10. [Thrombophlebitis in the central vein catheter (AVA3Xi) custody to the internal jugular vein: a case report].

    PubMed

    Morohashi, Toru; Ogura, Takahiro; Inamura, Rie; Kazama, Tomiei

    2012-06-01

    The central vein catheter-related infection and thrombosis are comparatively frequent and may cause a serious complication. AVA3Xi was taken into custody to the internal jugular vein, and the patient suffured from thrombophlebitis on the seventh day after the operation. A 73-year-old woman 151 cm tall and weighing 50 kg was scheduled for pancreatoduodenectomy under propofol-remifentanil anesthesia combined with epidural anesthesia (operating time 9 hours and 21 minutes, anesthetizing time 12 hours and 1 minute). The past history of the thrombosis was not present, and it was especially unquestionable for the trap including the preoperative testing and the central venous catheter insertion. The time course after the operation was also good. But the patient claimed the stiffness of the cervix on the postoperative seventh day; fever and shivering were also accompanied. S. epidermidis was identified by the blood culture. Thrombophlebitis was diagnosed with CT. It is necessary to choose an appropriate catheter and endeavor for the prevention and early detection of the blood clot formation to prevent catheter-related infection and thrombosis with cooperation with the surgeon.

  11. Anatomical Variations of the Right Adrenal Vein: Concordance Between Multidetector Computed Tomography and Catheter Venography.

    PubMed

    Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei

    2017-03-01

    Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.

  12. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.

    PubMed

    Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas

    2015-01-01

    Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach

  13. A Novel Microwave Catheter Can Perform Noncontact Circumferential Endocardial Ablation in a Model of Pulmonary Vein Isolation.

    PubMed

    Qian, Pierre; Barry, Michael Anthony; Nguyen, Trang; Ross, David; Kovoor, Pramesh; McEwan, Alistair; Thomas, Stuart; Thiagalingam, Aravinda

    2015-07-01

    Pulmonary vein isolation is an effective treatment for atrial fibrillation. Current endocardial ablation techniques require catheter contact for lesion formation. Inadequate or inconsistent catheter contact results in difficulty with achieving acute and long-term isolation and consequent atrial arrhythmia recurrence. Microwave energy produces radiant heating and therefore can be used for noncontact catheter ablation. We hypothesized that it is possible to design a microwave catheter to produce a circumferential transmural thermal lesion in an in vitro model of a pulmonary vein antrum. A monopole microwave catheter with a sideways firing axially symmetrical heating pattern was designed. Noncontact ablations were performed in a perfused pulmonary vein model constructed from microwave myocardial phantom embedded with a sheet of thermochromic liquid crystal to permit visualization and measurement of thermal lesions from color changes. 1200 J ablations were performed at 150 W for 80 seconds and 120 W for 100 seconds at high (0.8 L/min) and low (0.06 L/min) flow through the modeled pulmonary vein. Myocardial tissue was substituted for the phantom material and ablations repeated at 150 W for 180 seconds and stained with nitro-blue tetrazolium. The catheter was able to induce deep circumferential antral lesions in myocardial phantom and myocardial tissue. Higher power and shorter ablations delivering the same amount of microwave energy resulted in larger lesions with less surface sparing. A microwave catheter can be designed to produce a circumferential thermal lesion on noncontact ablation and may have possible applications for pulmonary vein isolation. © 2015 Wiley Periodicals, Inc.

  14. A retrospective comparative study of tunneled haemodialysis catheters inserted through occluded or collateral veins versus conventional methods.

    PubMed

    Powell, Steven; Chan, Tze Yuan; Bhat, Rammohan; Lam, Kimberly; Narlawar, Ranjeet S; Cullen, Nicola; Littler, Peter

    2010-08-01

    Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

  15. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    PubMed

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (<120 seconds) differed significantly between brachial vein and nonbrachial vein access (P = .001). There was no statistically significant difference between brachial vein and

  16. Pharmacomechanical Catheter-Directed Thrombolysis for Deep-Vein Thrombosis.

    PubMed

    Vedantham, Suresh; Goldhaber, Samuel Z; Julian, Jim A; Kahn, Susan R; Jaff, Michael R; Cohen, David J; Magnuson, Elizabeth; Razavi, Mahmood K; Comerota, Anthony J; Gornik, Heather L; Murphy, Timothy P; Lewis, Lawrence; Duncan, James R; Nieters, Patricia; Derfler, Mary C; Filion, Marc; Gu, Chu-Shu; Kee, Stephen; Schneider, Joseph; Saad, Nael; Blinder, Morey; Moll, Stephan; Sacks, David; Lin, Judith; Rundback, John; Garcia, Mark; Razdan, Rahul; VanderWoude, Eric; Marques, Vasco; Kearon, Clive

    2017-12-07

    The post-thrombotic syndrome frequently develops in patients with proximal deep-vein thrombosis despite treatment with anticoagulant therapy. Pharmacomechanical catheter-directed thrombolysis (hereafter "pharmacomechanical thrombolysis") rapidly removes thrombus and is hypothesized to reduce the risk of the post-thrombotic syndrome. We randomly assigned 692 patients with acute proximal deep-vein thrombosis to receive either anticoagulation alone (control group) or anticoagulation plus pharmacomechanical thrombolysis (catheter-mediated or device-mediated intrathrombus delivery of recombinant tissue plasminogen activator and thrombus aspiration or maceration, with or without stenting). The primary outcome was development of the post-thrombotic syndrome between 6 and 24 months of follow-up. Between 6 and 24 months, there was no significant between-group difference in the percentage of patients with the post-thrombotic syndrome (47% in the pharmacomechanical-thrombolysis group and 48% in the control group; risk ratio, 0.96; 95% confidence interval [CI], 0.82 to 1.11; P=0.56). Pharmacomechanical thrombolysis led to more major bleeding events within 10 days (1.7% vs. 0.3% of patients, P=0.049), but no significant difference in recurrent venous thromboembolism was seen over the 24-month follow-up period (12% in the pharmacomechanical-thrombolysis group and 8% in the control group, P=0.09). Moderate-to-severe post-thrombotic syndrome occurred in 18% of patients in the pharmacomechanical-thrombolysis group versus 24% of those in the control group (risk ratio, 0.73; 95% CI, 0.54 to 0.98; P=0.04). Severity scores for the post-thrombotic syndrome were lower in the pharmacomechanical-thrombolysis group than in the control group at 6, 12, 18, and 24 months of follow-up (P<0.01 for the comparison of the Villalta scores at each time point), but the improvement in quality of life from baseline to 24 months did not differ significantly between the treatment groups. Among patients

  17. Hepatic laceration because of malpositioning of the umbilical vein catheter: case report and literature review.

    PubMed

    Yiğiter, Murat; Arda, Irfan Serdar; Hiçsönmez, Akgün

    2008-05-01

    Umbilical vein catheterization that is a common bedside procedure in the neonatal intensive care units is not without complication. The most common complications are thrombus formation, embolism, vessel perforation, hemorrhage, and infection. Complications related to the liver carry a high risk for mortality. Laceration is an ominous complication of umbilical vein catheter that is generally a result of direct injury through the liver parenchyma. Abdominal distension that develops gradually should alert the physician for a likely development of intrahepatic bleeding. Surgery is mandatory in patients with ongoing bleeding after the withdrawal of the catheter. Early diagnosis and treatment are lifesaving in these patients.

  18. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    PubMed

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  19. Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia.

    PubMed

    Haines, David E; Stewart, Mark T; Dahlberg, Sarah; Barka, Noah D; Condie, Cathy; Fiedler, Gary R; Kirchhof, Nicole A; Halimi, Franck; Deneke, Thomas

    2013-02-01

    Cerebral diffusion-weighted MRI lesions have been observed after catheter ablation of atrial fibrillation. We hypothesized that conditions predisposing to microembolization could be identified using a porcine model of pulmonary vein ablation and an extracorporeal circulation loop. Ablations of the pulmonary veins were performed in 18 swine with echo monitoring. The femoral artery and vein were cannulated and an extracorporeal circulation loop with 2 ultrasonic bubble detectors and a 73-μm filter were placed in series. Microemboli and microbubbles were compared between ablation with an irrigated radiofrequency system (Biosense-Webster) and a phased radiofrequency multielectrode system (pulmonary vein ablation catheter [PVAC], Medtronic, Inc, Carlsbad, CA) in unipolar and 3 blended unipolar/bipolar modes. Animal pathology was examined. The size and number of microbubbles observed during ablation ranged from 30 to 180 μm and 0 to 3253 bubbles per ablation. Microbubble volumes with PVAC (29.1 nL) were greater than with irrigated radiofrequency (0.4 nL; P=0.045), and greatest with type II or III microbubbles on transesophageal echocardiography. Ablation with the PVAC showed fewest microbubbles in the unipolar mode (P=0.012 versus bipolar). The most occurred during bipolar energy delivery with overlap of proximal and distal electrodes (median microbubble volume, 1744 nL; interquartile range, 737-4082 nL; maximum, 19 516 nL). No cerebral MRI lesions were seen, but 2 animals had renal embolization. Left atrial ablation with irrigated radiofrequency and PVAC catheters in swine is associated with microbubble and microembolus production. Avoiding overlap of electrodes 1 and 10 on PVAC should reduce the microembolic burden associated with this procedure.

  20. [Prevalence of stenosis and thrombosis of central veins in hemodialysis after a tunneled jugular catheter].

    PubMed

    Jean, G; Vanel, T; Chazot, C; Charra, B; Terrat, J C; Hurot, J M

    2001-01-01

    Central venous stenosis (ST) and thrombosis (TB) related to catheter (KT) had been reported mostly for the subclavian vein. We performed a systematic cavographic study to evaluate the prevalence of these complications in 51 hemodialysis patients with present or previous history of tunneled internal jugular catheter. Each of them had used one or several KT (1.8 +/- 1.4 KT) for a mean 28 +/- 26 month cumulative time (i.e. 43,584 days total exposure time). Fifty percent of the KT were PermCath Quinton and 50% were Twincath (uncuffed) or CS 100 (cuffed) Medcomp. Twenty-seven had no ST (53%, group I), 24 had one or several significant ST (47%, group II) of superior Vena Cava (SVC, n = 4), inferior Vena Cava (IVC, n = 1), Brachio-cephalic Vein (BCV, n = 5) and subclavian vein (SC, n = 10), or a TB of SVC (n = 1), IVC (n = 3), BCV (n = 3), SC (n = 2). This accounts for an incidence of 0.55 ST or TB/1000 patient-days. Five of the twelve subclavian ST and TB had no history of previous subclavian catheter. Comparison between the two groups showed no differences according to age, time on dialysis, diabetes, hematocrit, CRP, cumulative time with catheter, catheter-related infections, type of catheter and anticoagulant treatment. IVC catheter tip's position is an important risk factor for TB and ST (4/6). Twelve group II patients had ST or TB-related symptoms, with a functional AV fistula in 9 cases. Eleven patients underwent repeated percutaneous angioplasty with 4 additional Wallstents and in 2 cases an AV fistula need to be closed. Central venous ST and TB after a jugular KT is extremely frequent, mostly without any symptoms. Consequences on peripheral or central vascular access, cost and poor long-term patency rate of angioplasty are of major importance. These results incite us to further reduce the catheter use in dialysis patients.

  1. Long-axis view for ultrasound-guided central venous catheter placement via the internal jugular vein.

    PubMed

    Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus

    2016-04-01

    In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.

  2. Tracing Fasting Glucose Fluxes with Unstressed Catheter Approach in Streptozotocin Induced Diabetic Rats

    PubMed Central

    Wu, Hui; Xu, Xiao; Meng, Ying; Xia, Fangzhen; Zhai, Hualing; Lu, Yingli

    2014-01-01

    Objective. Blood glucose concentrations of type 1 diabetic rats are vulnerable, especially to stress and trauma. The present study aimed to investigate the fasting endogenous glucose production and skeletal muscle glucose uptake of Streptozotocin induced type 1 diabetic rats using an unstressed vein and artery implantation of catheters at the tails of the rats as a platform. Research Design and Methods. Streptozotocin (65 mg·kg−1) was administered to induce type 1 diabetic state. The unstressed approach of catheters of vein and artery at the tails of the rats was established before the isotope tracer injection. Dynamic measurement of fasting endogenous glucose production was assessed by continuously infusing stable isotope [6, 6-2H2] glucose, while skeletal muscle glucose uptake by bolus injecting radioactively labeled [1-14C]-2-deoxy-glucose. Results. Streptozotocin induced type 1 diabetic rats displayed polydipsia, polyphagia, and polyuria along with overt hyperglycemia and hypoinsulinemia. They also had enhanced fasting endogenous glucose production and reduced glucose uptake in skeletal muscle compared to nondiabetic rats. Conclusions. The dual catheters implantation at the tails of the rats together with isotope tracers injection is a save time, unstressed, and feasible approach to explore the glucose metabolism in animal models in vivo. PMID:24772449

  3. Left spermatic vein retrograde sclerosis: comparison between sclerosant agent injection through a diagnostic catheter versus through an occluding balloon catheter.

    PubMed

    Basile, Antonio; Failla, Giovanni; La Vignera, Sandro; Condorelli, Rosita Angela; Calogero, Aldo; Vicari, Enzo; Granata, Antonio; Mundo, Elena; Caltabiano, Giuseppe; Pizzarelli, Marco; Messina, Martina; Scavone, Giovanni; Lanzafame, Franz; Iezzi, Roberto; Tsetis, Dimitrios

    2015-05-01

    The aim of this study was to compare the technical success between left spermatic vein (LSV) scleroembolisation achieved with the injection of sclerosant through a diagnostic catheter and through an occluding balloon (OB), in the treatment of male varicocele. From January 2012 to September 2013, we prospectively enrolled 100 patients with left varicocele and an indication for LSV scleroembolisation related to symptoms or spermiogram anomalies; patients were randomised to two groups (we wrote a list of 100 lines assigned casually with A or B and each patient was consecutively allocated to group A or B on the basis of this list). Patients in group A underwent injection of the sclerosing agent through an angiographic diagnostic catheter (free catheter technique) and patients in group B through an OB catheter (OB technique). In cases of incomplete occlusion of the LSV, the procedure was completed with coils. Total occlusion of the LSV at post-treatment phlebography during a Valsalva manoeuvre before any coil embolisation was considered a technical success. The rate of complications was also evaluated. The Fischer's test was used for statistical analysis. We evaluated a total of 90 patients because five patients for each group were not included in the statistical analysis owing to technical problems or complications. In group A we had a technical success of 75.6 versus 93.4 % in group B, and the difference was statistically significant (P = 0.003); in particular, we had to complete the embolisation with insertion of coils in 11 cases (24.4 %) in group A, and in three cases in group B (6.6 %). In group A, LSV rupture occurred in four cases (8 %) so the procedure was completed by sclerosant injection through the OB located distally to the lesion. These patients were not considered for evaluation. In another case, a high flow shunt towards the inferior vena cava was detected, so the patient underwent OB injection to stop the flow to the shunt, and was not included

  4. Dimerized plasmin fragment D as a potential biomarker to predict successful catheter-directed thrombolysis therapy in acute deep vein thrombosis.

    PubMed

    Luo, Chien-Ming; Wu, I-Hui; Chan, Chih-Yang; Chen, Yih-Sharng; Yang, Wei-Shiung; Wang, Shoei-Shen

    2015-10-01

    The value of dimerized plasmin fragment D in the clinical monitoring during the catheter-directed thrombolysis in patients with acute deep vein thrombosis is not known. Dimerized plasmin fragment D levels in 24 patients with acute deep vein thrombosis undergoing catheter-directed thrombolysis were prospectively evaluated. The plasma dimerized plasmin fragment D level was measured serially before and at every 12 h during catheter-directed thrombolysis for 24 h. Technical success was defined as restoration of patency and flow with less than 50% residual thrombus by surveillance rotational venography. Technical success was achieved in 79.2% (19 of 24) of the treated limbs after catheter-directed thrombolysis. In univariate analysis, there was significant elevation of the dimerized plasmin fragment D at 12th h after starting the catheter-directed thrombolysis (P < 0.05) in patients with less than 50% residual thrombus stenosis. The optimal cut-off value of dimerized plasmin fragment D to predict successful catheter-directed thrombolysis was determined as 18.4 µg/ml at the 12th h after starting the catheter-directed thrombolysis with sensitivity 0.8 and specificity 0.8 (P = 0.03). It was further validated in multivariate logistic regression analysis (odds ratio: 14.38; 95% CI: 1.22-169.20; P = 0.03). Catheter-directed thrombolysis is safe and effective for restoration of blood flow in patients with acute deep vein thrombosis. Dimerized plasmin fragment D value greater than 18.4 µg/ml at the 12th h after starting catheter-directed thrombolysis had a high predictive rate of greater than 50% lysis at the end of catheter-directed thrombolysis. © The Author(s) 2014.

  5. Is catheter-directed foam sclerotherapy more effective than the usual foam sclerotherapy for treatment of the great saphenous vein?

    PubMed

    Camillo, Orsini

    2018-01-01

    Objective This retrospective study presents the long-term results of catheter-directed foam sclerotherapy of the great saphenous vein. Method From January 2003 to June 2017, 277 patients with varices and great saphenous vein incompetence were treated with echo-guided foam sclerotherapy. Forty-six patients were treated with long-catheters guided by foam sclerotherapy. Foaming was carried out with sodium-tetra-decyl-sulphate. Results Results were examined in the two groups: A (long-catheters) and B (other procedures). The median overall follow-up was 52.1 months. In the A-group, the complete occlusion rate was 34/46 pts (73.9%) and partial occlusion was 10/46 (21.7%). In the B-group, respectively, 130/231 (56.2%) and 90/231 (38.9%). Comparisons between groups were statistically significant (p = 0.023; p = 0.021). Failures involved, respectively, 2/46 (4.3%) and 11/231 (4.7%) with no statistical significance. The complication rates were similar in the two groups. Conclusions In this long-term experience (median follow-up exceeding four years), foam-guided sclerotherapy of the great saphenous vein with a long-catheter turned out to be more effective than the usual foam-guided sclerotherapy.

  6. Hemodialysis Tunneled Catheter Noninfectious Complications

    PubMed Central

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922

  7. Catheter-Directed Thrombolysis via Small Saphenous Veins for Treating Acute Deep Venous Thrombosis.

    PubMed

    Yang, Bin; Xu, Xiao-Dong; Gao, Peng; Yu, Ji-Xiang; Li, Yu; Zhu, Ai-Dong; Meng, Ran-Ran

    2016-08-23

    BACKGROUND There is little data comparing catheter-directed thrombolysis (CDT) via small saphenous veins vs. systematic thrombolysis on complications and efficacy in acute deep venous thrombosis patients. The aim of our study was to compare the efficacy and safety of CDT via the small saphenous veins with systematic thrombolysis for patients with acute deep venous thrombosis (DVT). MATERIAL AND METHODS Sixty-six patients with acute DVT admitted from June 2012 to December 2013 were divided into 2 groups: 27 patients received systemic thrombolysis (ST group) and 39 patients received CDT via the small saphenous veins (CDT group). The thrombolysis efficiency, limb circumference differences, and complications such as post-thrombotic syndrome (PTS) in the 2 groups were recorded. RESULTS The angiograms demonstrated that all or part of the fresh thrombus was dissolved. There was a significant difference regarding thrombolysis efficiency between the CDT group and ST group (71.26% vs. 48.26%, P=0.001). In both groups the postoperative limb circumference changes were higher compared to the preoperative values. The differences between postoperative limb circumferences on postoperative days 7 and 14 were significantly higher in the CDT group than in the ST group (all P<0.05). The incidence of postoperative PTS in the CDT group (17.9%) was significantly lower in comparison to the ST group (51.85%) during the follow-up (P=0.007). CONCLUSIONS Catheter-directed thrombolysis via the small saphenous veins is an effective, safe, and feasible approach for treating acute deep venous thrombosis.

  8. Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator.

    PubMed

    Fredersdorf, Sabine; Weber, Stefan; Jilek, Clemens; Heinicke, Norbert; VON Bary, Christian; Jungbauer, Carsten; Riegger, Günter A; Hamer, Okka W; Jeron, Andreas

    2009-10-01

    Ablation of atrial fibrillation (AF) has been one of the most difficult and time-consuming electrophysiological procedures. Due to the rapidly increasing demand for ablation procedures, technical advances would be helpful to reduce complexity and procedure time in AF ablation. Therefore, we investigated the feasibility of a single-catheter technique for pulmonary vein (PV) isolation utilizing a decapolar catheter combined with a duty-cycled, unipolar-bipolar radiofrequency (RF) generator. AF mapping and ablation was performed in 21 consecutive patients (mean age 59 +/- 12 years, 9 males) with paroxysmal AF (n = 17) and persistent AF (n = 4). The ablation catheter was forwarded to the LA via single-transseptal puncture. All electrodes were energized in 2 to 5 applications per vein, followed by segmental RF applications, as needed, to achieve electrical isolation. To assess left atrial anatomy for purposes of catheter manipulation, and later evaluate the possibility of asymptomatic PV-stenosis, CT or MR imaging was performed both prior to ablation and at 6-month follow-up. Isolation could be achieved in 85/86 veins (99%). Procedure time for ablation was 81 +/- 13 minutes, and fluoroscopy time was 30 +/- 11 minutes. There were no procedural complications. Success rate at 6 months was 86% (18/21). MR or CT imaging excluded asymptomatic PV-stenosis. Mapping and ablation of PVs can be performed in a safe and efficient manner using a single-catheter technique, with short procedure times and minimal learning curve. Thus, this system may be of high interest not only for high volume but all centers performing AF ablation.

  9. Central Venous Catheter Placement in the Left Internal Jugular Vein Complicated by Perforation of the Left Brachiocephalic Vein and Massive Hemothorax: A Case Report.

    PubMed

    Wetzel, Lindsay R; Patel, Priyesh R; Pesa, Nicholas L

    2017-07-01

    An elderly male presented for emergent repair of a ruptured abdominal aortic aneurysm. For anticipated volume resuscitation, vasopressor administration, and hemodynamic monitoring, a large-bore central venous catheter was placed in the left internal jugular vein under ultrasound guidance before surgical incision. Initially, there were no readily apparent signs of venous perforation. However, a massive left hemothorax developed because of perforation of the brachiocephalic vein and violation of the pleural space. This case report discusses both prevention and management of such a complication.

  10. Risk factors associated with catheter-related upper extremity deep vein thrombosis in patients with peripherally inserted central venous catheters: literature review: part 1.

    PubMed

    Clemence, Bonnie J; Maneval, Rhonda E

    2014-01-01

    This is part 1 of a 2-part series of articles that report on the results of a prospective observational cohort study designed to examine the risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters. This article provides an extensive review and critique of the literature that serves to explicate what is currently known about risk factors associated with catheter-related UEDVT. Risk factors such as anticoagulant use, cancer, infection, hypertension, catheter tip placement, and catheter size were identified most frequently in the literature as being associated with UEDVT development. Other risk factors--such as obesity, smoking history, surgery, and presence of pain or edema--were examined in a limited number of studies and lacked consistent evidence of their impact on UEDVT development. The subsequent study that evolved from the review of the literature investigates the relationship between identified risk factors and UEDVT development.

  11. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  12. A simplified technique of percutaneous hepatic artery port-catheter insertion for the treatment of advanced hepatocellular carcinoma with portal vein invasion.

    PubMed

    Choi, Sun Young; Kim, Ah Hyun; Kim, Kyung Ah; Won, Jong Yun; Lee, Do Yun; Lee, Kwang-Hun

    2010-01-01

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis.

  13. Related factors with extravasation of non-cytostatic agents in peripheral vein catheters.

    PubMed

    Fernández-García, Cristina; Mata-Peón, Esther; Avanzas-Fernández, Sara

    To know the independent variables related to the occurrence of extravasation in patients with peripheral vein catheters (PVC). Retrospective study carried out in 6 longitudinal cuts between July 2013 an January 2014. A total of 1,442 PVC were reviewed, of which 730 met the inclusion criteria, and were divided into 2 groups: extravasation and not extravasation, with 365 cases each. The variables of age, gender, admission unit, catheter gauge, insertion site, previous insertion into the same limb, hospital unit where the insertion took place, communication difficulties, personal health history and analyzed parenterally drug administered were considered. Risk factors to develop extravasation were: female gender, with previous insertion in the same limb, <72h PVC of insertion, communication difficulties, personal health history of neoplasia and KCl, gentamicin or beta lactam treatment. Our study allows to know the variables that are related to the emergence of extravasations in patients with non-cancer treatments (gender, medical service of admission, catheter gauge, elapsed time since the insertion, patient communication difficulties, personal health history, and intravenous treatments), as well as the factors that may be considered protective. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  14. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teichgraeber, Ulf Karl-Martin, E-mail: ulf.teichgraeber@charite.de; Streitparth, Florian, E-mail: florian.streitparth@charite.d; Gebauer, Bernhard, E-mail: bernhard.gebauer@charite.d

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition whenmore » required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.« less

  15. Catheter-Directed Thrombolysis of Acute Deep Vein Thrombosis in the Lower Extremity of a Child with Interrupted Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Ozkan, Ugur; Tercan, Fahri

    2007-04-15

    We present the case of a 14-year-old girl who developed acute deep vein thrombosis (DVT) in her right lower extremity. Laboratory testing revealed protein S deficiency, and the patient's father also had this abnormality with a history of lower extremity DVT. Manual thromboaspiration followed by catheter-directed thrombolysis resulted in total clearance of all thrombi. Computed tomography and later venography revealed an interrupted inferior vena cava. Catheter-directed thrombolysis is an established treatment for adults with acute DVT. To the best of our knowledge, this report is the first to describe catheter-directed thrombolysis in a pediatric patient with lower extremity DVT. Ourmore » results suggest that catheter-directed thrombolysis is safe and effective for use in selected older children and adolescents with acute DVT in the lower extremity.« less

  16. Black pepper essential oil to enhance intravenous catheter insertion in patients with poor vein visibility: a controlled study.

    PubMed

    Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane

    2012-11-01

    To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.

  17. The retrobulbar sinus is superior to the lateral tail vein for the injection of contrast media in small animal cardiac imaging.

    PubMed

    Socher, M; Kuntz, J; Sawall, S; Bartling, S; Kachelrieß, M

    2014-04-01

    Cardiac perfusion studies using computed tomography are a common tool in clinical practice. Recent technical advances and the availability of dedicated small animal scanners allow the transfer of these techniques to the preclinical sector in general and to mouse models of cardiac diseases in particular. This necessitates new requirements for contrast injection techniques as a rapid transport of contrast media from the intravenous access to the animal heart. Clinical contrast agents containing high iodine concentrations are used within small animal studies although they exhibit a high viscosity which might limit their transport within the vasculature. The authors provide a comparison of the transport of contrast media following an injection into the lateral tail vein and an injection into the retrobulbar sinus and discuss the anatomy involved. The temporal evolution of a contrast bolus and its in vivo distribution is visualized. It is demonstrated that injecting contrast agents into the lateral tail vein of mice results in a retrograde blood flow to the liver veins and therefore does not deliver a detectable contrast bolus to the heart, and thus it cannot be used for cardiac perfusion studies. By contrast, boli injected into the retrobulbar sinus are rapidly transported to the heart and provide ventricular contrast enabling perfusion studies similar to those in human patients. The results demonstrate that an injection into the retrobulbar sinus is superior to an injection into the lateral tail vein for the delivery of contrast boli to the animal heart, while all drawbacks of an injection into the lateral tail vein are overcome.

  18. Hemothorax as a complication of subclavian vein cannulation with haemodialysis catheter - case report.

    PubMed

    Iwańczuk, Waldemar; Guźniczak, Piotr; Kasperczak, Jarosław

    2013-01-01

    We present the case of a 39 year-old male patient admitted to ICU with symptoms of acute metabolic acidosis. He was investigated for the presence of methanol and glycol. Conservative treatment was initially started, followed by haemodialysis. During insertion of a temporary haemodialysis catheter in a location of Haapaniemi and Slatis, the patient was conscious but restless; therefore sedation was required to continue the procedure. After three hours of haemodialysis, the patient's general condition suddenly deteriorated. Hypovolemic shock and acute respiratory distress led to hypothesis of right haemothorax, which was rapidly confirmed by angio-CT examination. Trachea was intubated, drainage of right pleura was performed and aggressive fluid treatment begun. The patient was admitted to the operating theatre, and thoracotomy with reconstruction of damaged right venous angle was carried out. After the operation, the patient was transferred to ICU. He was mechanically ventilated and remained haemodynamically unstable. Although fluids and blood-made concentrates were transfused and catecholamines continuously administered, his clinical condition deteriorated and finally the patient died. We found two independent causes of this fatality: hypovolemic shock and acute extrinsic metabolic acidosis. However, this paper focuses on the problem of the iatrogenic complication, which was haemothorax. In the literature there are described examples of such cases. Authors emphasise the most traumatic moment of cannulation as being insertion of the guidewire and dilator to perform a tunnel for the catheter. Puncture by needle and localisation of the central vein results in fewer complications. Furthermore, we strongly recommend monitoring patients after central veins cannulation. All sudden deteriorations in clinical condition should be followed by meticulous diagnosis for the presence of this life-threatening complication.

  19. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter.

    PubMed

    Wasmer, K; Foraita, P; Leitz, P; Güner, F; Pott, C; Lange, P S; Eckardt, L; Mönnig, G

    2016-01-01

    Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P < 0.001), RF duration (24 ± 10 vs. 49 ± 25 min; P < 0.001), and fluoroscopy time (21 ± 10 vs. 35 ± 13 min; P < 0.001) were significantly shorter using PVAC. Major complication rates [major bleeding, transitoric ischaemic attack (TIA), and pericardial tamponade] were not significantly different between groups (PVAC, n = 3; 2% vs. iRF n = 17; 6%). Overall complication rate, including minor events, was similar in both groups [n = 21 (14%) vs. n = 48 (16%)]. Most of these were bleeding complications due to vascular access [n = 8 (5.3%) vs. n = 22 (7.3%)], which required surgical intervention in five patients [n = 1 (0.7%) vs. n = 4 (1.3%)]. Pericardial effusion [n = 4 (2.7%) vs. n = 19 (6.3%); pericardial tamponade requiring drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode

  20. Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness.

    PubMed

    Pambrun, Thomas; Combes, Stéphane; Sousa, Pedro; Bloa, Mathieu Le; El Bouazzaoui, Rim; Grand-Larrieu, Delphine; Thompson, Nathaniel; Martin, Ruairidh; Combes, Nicolas; Boveda, Serge; Haïssaguerre, Michel; Albenque, Jean-Paul

    2017-03-01

    For conventional ablation of paroxysmal atrial fibrillation (AF), an ablation catheter in conjunction with a circular mapping catheter (CMC) is typically used for pulmonary vein isolation (PVI). The purpose of this study was to evaluate an approach for PVI with a single contact-force (CF) ablation catheter in terms of procedural reliability, outcomes, and cost-effectiveness. One hundred consecutive patients with paroxysmal AF were included in the study. Fifty patients (study group) underwent a CF-guided single-catheter approach, whereby PVI was demonstrated when sequential pacing at 9 equidistant points within the lesion set (carina included) failed to capture the left atrium. For confirmation, PVI was verified with a CMC. In comparison, 50 patients (control group) underwent a conventional PVI ablation guided by a CMC. Procedure time (101 ± 17 minutes vs 107 ± 15 minutes, P = .11), ablation time (24.2 ± 7.1 minutes vs 22.6 ± 8.8 minutes, P = .37), fluoroscopy time (5.6 ± 2.2 minutes vs 8.3 ± 3.4 minutes, P = .09), and applied CF (17.8 ± 2.6 g vs 18 ± 2.8 g, P = .72) did not reach statistical difference between the study and control groups. CF-guided single-catheter ablation achieved successful PVI in 98% of the study group and a 31% reduction in cost. At 1-year follow-up, sinus rhythm maintenance rate was similar in both groups (86% vs 84%, P = .78). In paroxysmal AF, a CF-guided single-catheter technique is an effective method for PVI, yielding substantial cost savings and clinical results similar to a conventional approach. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial

    PubMed Central

    De Greef, Yves; Dekker, Lukas; Boersma, Lucas; Murray, Stephen; Wieczorek, Marcus; Spitzer, Stefan G.; Davidson, Neil; Furniss, Steve; Hocini, Mélèze; Geller, J. Christoph; Csanádi, Zoltan

    2016-01-01

    Abstract Aims This prospective, multicentre study (PRECISION GOLD) evaluated the incidence of asymptomatic cerebral embolism (ACE) after pulmonary vein isolation (PVI) using a new gold multi-electrode radiofrequency (RF) ablation catheter, pulmonary vein ablation catheter (PVAC) GOLD. Also, procedural efficiency of PVAC GOLD was compared with ERACE. The ERACE study demonstrated that a low incidence of ACE can be achieved with a platinum multi-electrode RF catheter (PVAC) combined with procedural manoeuvres to reduce emboli. Methods and results A total of 51 patients with paroxysmal atrial fibrillation (AF) (age 57 ± 9 years, CHA2DS2-VASc score 1.4 ± 1.4) underwent AF ablation with PVAC GOLD. Continuous oral anticoagulation using vitamin K antagonists, submerged catheter introduction, and heparinization (ACT ≥ 350 s prior to ablation) were applied. Cerebral magnetic resonance imaging (MRI) scans were performed within 48 h before and 16–72 h post-ablation. Cognitive function assessed by the Mini-Mental State Exam at baseline and 30 days post-ablation. New post-procedural ACE occurred in only 1 of 48 patients (2.1%) and was not detectable on MRI after 30 days. The average number of RF applications per patient to achieve PVI was lower in PRECISION GOLD (20.3 ± 10.0) than in ERACE (28.8 ± 16.1; P = 0.001). Further, PVAC GOLD ablations resulted in significantly fewer low-power (<3 W) ablations (15 vs. 23%, 5 vs. 10% and 2 vs. 7% in 4:1, 2:1, and 1:1 bipolar:unipolar energy modes, respectively). Mini-Mental State Exam was unchanged in all patients. Conclusion Atrial fibrillation ablation with PVAC GOLD in combination with established embolic lowering manoeuvres results in a low incidence of ACE. Pulmonary vein ablation catheter GOLD demonstrates improved biophysical efficiency compared with platinum PVAC. Trial registration ClinicalTrials.gov NCT01767558. PMID:26826134

  2. Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe

    PubMed Central

    Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.

    2014-01-01

    Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628

  3. In Vitro and In Vivo Effectiveness of an Innovative Silver-Copper Nanoparticle Coating of Catheters To Prevent Methicillin-Resistant Staphylococcus aureus Infection

    PubMed Central

    Ballo, Myriam K. S.; Pulgarin, César; Hopf, Nancy; Berthet, Aurélie; Kiwi, John; Moreillon, Philippe; Bizzini, Alain

    2016-01-01

    In this study, silver/copper (Ag/Cu)-coated catheters were investigated for their efficacy in preventing methicillin-resistant Staphylococcus aureus (MRSA) infection in vitro and in vivo. Ag and Cu were sputtered (67/33% atomic ratio) on polyurethane catheters by direct-current magnetron sputtering. In vitro, Ag/Cu-coated and uncoated catheters were immersed in phosphate-buffered saline (PBS) or rat plasma and exposed to MRSA ATCC 43300 at 104 to 108 CFU/ml. In vivo, Ag/Cu-coated and uncoated catheters were placed in the jugular vein of rats. Directly after, MRSA (107 CFU/ml) was inoculated in the tail vein. Catheters were removed 48 h later and cultured. In vitro, Ag/Cu-coated catheters preincubated in PBS and exposed to 104 to 107 CFU/ml prevented the adherence of MRSA (0 to 12% colonization) compared to uncoated catheters (50 to 100% colonization; P < 0.005) and Ag/Cu-coated catheters retained their activity (0 to 20% colonization) when preincubated in rat plasma, whereas colonization of uncoated catheters increased (83 to 100%; P < 0.005). Ag/Cu-coating protection diminished with 108 CFU/ml in both PBS and plasma (50 to 100% colonization). In vivo, Ag/Cu-coated catheters reduced the incidence of catheter infection compared to uncoated catheters (57% versus 79%, respectively; P = 0.16) and bacteremia (31% versus 68%, respectively; P < 0.05). Scanning electron microscopy of explanted catheters suggests that the suboptimal activity of Ag/Cu catheters in vivo was due to the formation of a dense fibrin sheath over their surface. Ag/Cu-coated catheters thus may be able to prevent MRSA infections. Their activity might be improved by limiting plasma protein adsorption on their surfaces. PMID:27353266

  4. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonsalves, Carin F., E-mail: Carin.Gonsalves@mail.tju.edu; Eschelman, David J.; Sullivan, Kevin L.

    2003-04-15

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine cathetermore » dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access

  5. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial.

    PubMed

    De Greef, Yves; Dekker, Lukas; Boersma, Lucas; Murray, Stephen; Wieczorek, Marcus; Spitzer, Stefan G; Davidson, Neil; Furniss, Steve; Hocini, Mélèze; Geller, J Christoph; Csanádi, Zoltan

    2016-05-01

    This prospective, multicentre study (PRECISION GOLD) evaluated the incidence of asymptomatic cerebral embolism (ACE) after pulmonary vein isolation (PVI) using a new gold multi-electrode radiofrequency (RF) ablation catheter, pulmonary vein ablation catheter (PVAC) GOLD. Also, procedural efficiency of PVAC GOLD was compared with ERACE. The ERACE study demonstrated that a low incidence of ACE can be achieved with a platinum multi-electrode RF catheter (PVAC) combined with procedural manoeuvres to reduce emboli. A total of 51 patients with paroxysmal atrial fibrillation (AF) (age 57 ± 9 years, CHA2DS2-VASc score 1.4 ± 1.4) underwent AF ablation with PVAC GOLD. Continuous oral anticoagulation using vitamin K antagonists, submerged catheter introduction, and heparinization (ACT ≥ 350 s prior to ablation) were applied. Cerebral magnetic resonance imaging (MRI) scans were performed within 48 h before and 16-72 h post-ablation. Cognitive function assessed by the Mini-Mental State Exam at baseline and 30 days post-ablation. New post-procedural ACE occurred in only 1 of 48 patients (2.1%) and was not detectable on MRI after 30 days. The average number of RF applications per patient to achieve PVI was lower in PRECISION GOLD (20.3 ± 10.0) than in ERACE (28.8 ± 16.1; P = 0.001). Further, PVAC GOLD ablations resulted in significantly fewer low-power (<3 W) ablations (15 vs. 23%, 5 vs. 10% and 2 vs. 7% in 4:1, 2:1, and 1:1 bipolar:unipolar energy modes, respectively). Mini-Mental State Exam was unchanged in all patients. Atrial fibrillation ablation with PVAC GOLD in combination with established embolic lowering manoeuvres results in a low incidence of ACE. Pulmonary vein ablation catheter GOLD demonstrates improved biophysical efficiency compared with platinum PVAC. ClinicalTrials.gov NCT01767558. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  6. Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.

    PubMed

    Stabile, Giuseppe; Anselmino, Matteo; Soldati, Ezio; De Ruvo, Ermengildo; Solimene, Francesco; Iuliano, Assunta; Sciarra, Luigi; Bongiorni, Maria Grazia; Calò, Leonardo; Gaita, Fiorenzo

    2017-03-01

    Left atrial volume (LA) and pulmonary vein (PV) anatomy may potentially relate to technical challenges in achieving stable and effective catheter position in case of atrial fibrillation (AF) ablation by means of "one-shot" catheters. The aim of this study was to investigate whether LA volume and PV anatomy, evaluated by computed tomography (CT) or magnetic resonance (MR) prior to ablation, predict acute and midterm outcome of AF ablation by nMARQ™. We included 75 patients (mean age 58 ± 11 years, 67 % male) with symptomatic paroxysmal AF. All patients underwent CT/MR scanning prior to catheter ablation to evaluate LA volume and PV anatomy. All the patients underwent PV isolation by nMARQ™, an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter. Ablation was guided by electroanatomic mapping allowing RF energy delivery in the antral region of PVs from ten irrigated electrodes simultaneously. Mean LA volume was 75 ± 40 ml. A normal anatomy (4 PVs) was documented in 40 (53 %) patients and abnormal anatomy (common truncus or accessory PVs) in 35 patients. Mean procedural and fluoroscopy times were 94 ± 55 and 8 ± 5 min, respectively, without significant differences among patients with normal or abnormal anatomy (92 ± 45 vs 95 ± 64 min, p = 0.85 and 6 ± 3 vs 8 ± 4 min, p = 0.65, respectively). Mean ablation time was 14 ± 3 min, and 99 % of the targeted veins were isolated with a mean of 23 ± 5 RF pulses per patient. After a mean follow-up of 17 ± 8 months, 23 (31 %) patients had an atrial arrhythmia recurrence. Neither LA volume nor PV anatomy was a predictor of outcome. LA volume and PV anatomy did not affect procedural data and outcome in patients who underwent PV isolation by an open-irrigated mapping and RF decapolar ablation catheter.

  7. "Do Not Follow the Tail": A Practical Approach to Remove a Sheared Lumbar Catheter Fragment Avoiding Its Migration into the Spinal Canal.

    PubMed

    Oshino, Satoru; Kishima, Haruhiko; Ohnishi, Yu-ichiro; Iwatsuki, Koichi; Saitoh, Youichi

    2016-03-01

    Catheter shearing is one of the most common complications of various neurosurgical modalities that use an intrathecal lumbar catheter. The sheared catheter fragment often can spontaneously migrate into the spinal canal; however, in some cases, the end of the fragment will remain outside the spinal canal. In this situation, the consulting neurosurgeons may try to retrieve the catheter fragment by approaching it directly through the catheter tract. This simple maneuver, however, can cause the fragment to slip into the spinal canal before it is secured, as we experienced recently in 2 cases. Because the fragment of the sheared catheter slipped while manipulating it within the catheter tract, we suggest that surgeons not approach the fragment along the tract to prevent it from migrating downward. Using the operative findings of an illustrative case, we describe how to avoid downward migration of the catheter fragment when retrieving a sheared lumbar catheter. We found that the sheared catheter of a lumbar-peritoneal shunt was slowly slipping along with the pulsatile movement of cerebrospinal fluid within the catheter tract. We successfully retrieved the fragment by approaching it from outside the catheter tract. We propose that surgeons approach the fragment from outside of the catheter tract. One should keep in mind a simple phrase, 'Do not follow the tail', when retrieving the sheared lumbar catheter fragment. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Insertion of tunneled hemodialysis catheters without fluoroscopy.

    PubMed

    Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio

    2010-01-01

    The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.

  9. [Periinterventional prophylactic antibiotics in radiological port catheter implantation].

    PubMed

    Gebauer, B; Teichgräber, U; Werk, M; Wagner, H-J

    2007-08-01

    To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n = 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters.

  10. Peripheral Intravenous Catheterisation in Obstetric Patients in the Hand or Forearm Vein: A Randomised Trial

    PubMed Central

    Tan, Peng Chiong; Mackeen, Anjana; Khong, Su Yen; Omar, Siti Zawiah; Azmi, M. A. Noor

    2016-01-01

    A peripheral intravenous catheter is often inserted as part of care during labour. The catheter is inserted into the back of the hand or lower forearm vein in usual practice. There is no trial data to guide the care provider on which is the better insertion site in any clinical setting. 307 women admitted to the labour ward who required insertion of intravenous catheter were randomised to back of hand or lower forearm vein catheter insertion. Catheter insertion is by junior to mid-grade providers. We evaluated insertion success at the first attempt, pain during insertion and catheter replacement due to malfunction as main outcomes. After catheter removal, we recorded patient satisfaction with site, future site preference and insertion site swelling, bruising, tenderness, vein thrombosis and pain. Insertion of a catheter into back of hand vein is more likely to be successful at the first attempt. Insertion pain score, catheter replacement rate, patient satisfaction, patient fidelity to site in a future insertion and insertion site complications rate are not different between trial arms. In conclusion, both insertion sites are suitable; the back of the hand vein maybe easier to cannulate and seems to be preferred by our frontline providers. PMID:26987593

  11. Understanding the Patient Experience of Peripherally Inserted Central Catheter-Related Deep Vein Thrombosis Using Interpretive Phenomenology.

    PubMed

    Meyer, Britt M

    The purpose of this interpretive phenomenological study was to determine what it means to patients to live with a peripherally inserted central catheter (PICC)-related deep vein thrombosis and to describe the influence of the experience on the individual's quality of life. The sample included 11 adult patients from an acute care setting who developed a PICC-related symptomatic thrombus between November 2014 and March 2016, using purposive sampling. Three distinct themes emerged from the data in this study: a loss of trust in health care providers, additional burdens to existing problems, and a yearning for understanding.

  12. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizandari, Malkhaz; Ao, Guokun; Zhang Yaojun

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus.more » There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.« less

  13. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  14. Videothoracoscopic management of a perforated central vein and pleura after ultrasound-guided internal jugular vein cannulation: a case report

    PubMed Central

    Kim, Jeong-Eun; Jeon, Joon-Pyo; Kim, Yongsuk; Jeong, Su Ah

    2014-01-01

    A 23-year-old male underwent a left internal jugular vein catheterization during extended surgery for treatment of multiple fractures due to a traffic accident. Although the catheterization was performed under ultrasound (US) guidance, iatrogenic perforation of the central vein and pleura occurred. The catheter was removed, and the perforated site was addressed under thoracoscopy rather than an open thoracotomy. This case suggests that using US does not completely guarantee a complication-free outcome, and that catheter placement should be carefully confirmed. In addition, this case suggests that thoracoscopy may be an ideal method of resolving a perforation of the central vein and pleura. PMID:24851167

  15. Thrombus just beneath a retrievable inferior vena cava filter in a pregnant woman with deep vein thrombosis: its removal requiring catheter thrombus fragmentation with fibrinolysis.

    PubMed

    Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki

    2014-02-01

    Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  16. Respiratory motion influence on catheter contact force during radio frequency ablation procedures

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.

  17. Clinical outcomes of totally implantable venous access port placement via the axillary vein in patients with head and neck malignancy.

    PubMed

    Hong, Sun; Seo, Tae-Seok; Song, Myung Gyu; Seol, Hae-Young; Suh, Sang Il; Ryoo, In-Seon

    2018-06-01

    To evaluate the clinical outcomes and complications of totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy. A total of 176 totally implantable venous access ports were placed via the axillary vein in 171 patients with head and neck malignancy between May 2012 and June 2015. The patients included 133 men and 38 women, and the mean age was 58.8 years (range: 19-84 years). Medical records were retrospectively reviewed. This study included a total of 93,237 totally implantable venous access port catheter-days (median 478 catheter-days, range: 13-1380 catheter-days). Of the 176 implanted totally implantable venous access port, complications developed in nine cases (5.1%), with the overall incidence of 0.097 events/1000 catheter-days. The complications were three central line-associated blood-stream infection cases, one case of keloid scar at the needling access site, and five cases of central vein stenosis or thrombosis on neck computed tomography images. The 133 cases for which neck computed tomography images were available had a total of 59,777 totally implantable venous access port catheter-days (median 399 catheter-days, range: 38-1207 catheter-days). On neck computed tomography evaluation, the incidence of central vein stenosis or thrombosis was 0.083 events/1000 catheter-days. Thrombosis developed in four cases, yielding an incidence of 0.067 events/1000 catheter-days. All four patients presented with thrombus in the axillary or subclavian vein. Stenosis occurred in one case yielding an incidence of 0.017 events/1000 catheter-days. One case was catheter-related brachiocephalic vein stenosis, and the other case was subclavian vein stenosis due to extrinsic compression by tumor progression. Of the nine complication cases, six underwent port removal. These data indicate that totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy is safe and

  18. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  19. Abnormal gel flotation caused by contrast media during adrenal vein sampling.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare

    2016-10-15

    During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm 3 of density, was used close to the right adrenal vein due to some difficulty to access it. The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.

  20. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroepil, Patric; Lanzman, Rotem S., E-mail: rotemshlomo@yahoo.de; Miese, Falk R.

    2011-04-15

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thusmore » required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.« less

  1. A Randomized Controlled Comparison of the Internal Jugular Vein and the Subclavian Vein as Access Sites for Central Venous Catheterization in Pediatric Cardiac Surgery.

    PubMed

    Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash

    2016-09-01

    To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and

  2. [Injuries to blood vessels near the heart caused by central venous catheters].

    PubMed

    Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V

    2016-11-01

    Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.

  3. Prospective study of catheter-related central vein thrombosis in home parenteral nutrition patients with benign disease using serial venous Doppler ultrasound.

    PubMed

    Cuerda, Cristina; Joly, Francisca; Corcos, Olivier; Concejo, Javier; Puiggrós, Carolina; Gil, Carmen; Pironi, Loris

    2016-02-01

    Catheter-related central vein thrombosis (CRVT) is a severe complication of home parenteral nutrition (HPN) that may be clinically manifest or subclinical. The aims of the study were to prospectively investigate the incidence of CRVT in patients on HPN with benign disease and determine the influence of different variables on this complication. A prospective, multicentre, observational study in the Home Artificial Nutrition-Chronic Intestinal Failure ESPEN group was performed. Patients with benign disease starting HPN or already on HPN after the insertion of a new catheter, were recruited and followed up with Color Doppler Duplex Sonography (CDDS) evaluations at baseline, 1 week, 3, 6 and 12 months after catheter insertion. Fisher's exact test was used to calculate the association of different variables (related to the patient, type of catheter, vascular access, insertion method, catheter care and anticoagulant treatment) with CRVT events. Sixty-two patients (31 males, 31 females) aged 50 ± 19 (19-83) years were included and followed for a median 363 days, with an Inter Quartile Range of 180-365 days, and a total of 16,186 catheter-days. Six patients had previous CRVT and 16 had history of thromboembolic disease (pulmonary and mesenteric). Forty one patients were receiving anticoagulant treatment. Fifty two patients had tunneled catheters and 10 implanted ports. Two patients had symptomatic thrombosis at 3 and 12 months of follow-up (2 and 3 weeks after normal routine CDDS evaluation). The incidence of CRVT was 0.045/catheter/year. CRVT was not significantly associated with any of the variables analyzed. The incidence of CRVT in patients on HPN for benign disease followed by CDDS is low in the first year of catheterization. We did not observe any case of asymptomatic CRVT. Based on our data, CDDS seems to have low effectiveness as a screening tool for CRVT in asymptomatic patients on HPN with benign disease. Copyright © 2015 Elsevier Ltd and European Society for

  4. Single transseptal big Cryoballoon pulmonary vein isolation using an inner lumen mapping catheter.

    PubMed

    Chun, Kr Julian; Bordignon, Stefano; Gunawardene, Melanie; Urban, Verena; Kulikoglu, Mehmet; Schulte-Hahn, Britta; Nowak, Bernd; Schmidt, Boris

    2012-11-01

    The single big cryoballon technique for pulmonary vein isolation (PVI) has been limited by the need for two transseptal punctures (TP). We therefore investigated feasibility and safety of a simplified approach using a single TP and a novel circumferential mapping catheter (CMC). Patients underwent 28-mm cryoballoon PVI using a single TP. The CMC (Achieve(©) Medtronic Inc., Minneapolis, MN, USA) served as (1) guidewire and (2) as a PV mapping tool. Primary endpoint was PVI without switching to a regular guidewire. Secondary endpoints included: (1) PV signal quality during freezing, (2) time to PVI, (3) classification of successful ablation technique, (4) complications, and (5) procedural data. A total of 32 patients (126 PVs) were studied (mean age: 62 ± 11 years, 24 males, left atrium: 40 ± 4 mm). The primary endpoint was achieved in 29/32 patients (91%) and 123/126 PVs (98%) with a procedure and fluoroscopy time of 126 ± 26 minutes and 18.9 ± 7.5 minutes, respectively. Real-time visualization of PVI could be observed in 61/126 (48%) PVs. Time to sustained PVI versus nonsustained PVI was 66 ± 56 seconds versus 129 ± 76 seconds (P < 0.001). One phrenic nerve palsy was observed. After a follow-up of 250 ± 84 days 23/32 patients (72%) remained in sinus rhythm. The "simplified single big cryoballoon" PVI strategy appears to be safe and feasible. However, real-time PV recording was achieved in <50% of PVs. Therefore, further catheter refinements are warranted. (PACE 2012; 35:1304-1311). ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  5. Abnormal gel flotation caused by contrast media during adrenal vein sampling

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare

    2016-01-01

    Introduction During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. Materials and methods A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter’s position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. Results At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. Conclusion The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays. PMID:27812311

  6. Efficacy of Minocycline and EDTA Lock Solution in Preventing Catheter-Related Bacteremia, Septic Phlebitis, and Endocarditis in Rabbits

    PubMed Central

    Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert

    2002-01-01

    To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P < 0.01). Tricuspid endocarditis was equally prevented by vancomycin-heparin and M-EDTA (P ≤ 0.06). In conclusion, the M-EDTA catheter flush solution was highly efficacious in preventing catheter-related colonization, bacteremia, septic phlebitis, and endocarditis in rabbits. PMID:11796338

  7. Use of peripherally inserted central catheters as an alternative to central catheters in neurocritical care units.

    PubMed

    DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T

    2011-04-01

    Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.

  8. Idiopathic ventricular outflow tract arrhythmias from the great cardiac vein: challenges and risks of catheter ablation.

    PubMed

    Steven, D; Pott, C; Bittner, A; Sultan, A; Wasmer, K; Hoffmann, B A; Köbe, J; Drewitz, I; Milberg, P; Lueker, J; Mönnig, G; Servatius, H; Willems, S; Eckardt, L

    2013-11-20

    Catheter ablation for idiopathic ventricular arrhythmia is well established but epicardial origin, proximity to coronary arteries, and limited accessibility may complicate ablation from the venous system in particular from the great cardiac vein (GCV). Between April 2009 and October 2010 14 patients (56 ± 15 years; 9 male) out of a total group of 117 patients with idiopathic outflow tract tachycardias were included undergoing ablation for idiopathic VT or premature ventricular contractions (PVC) originating from GCV. All patients in whom the PVC arose from the GCV were subject to the study. In these patients angiography of the left coronary system was performed with the ablation catheter at the site of earliest activation. Successful ablation was performed in 6/14 (43%) and long-term success was achieved in 5/14 (36%) patients. In 4/14 patients (28.6%) ablation was not performed. In another 4 patients (26.7%), ablation did not abolish the PVC/VT. In the majority, the anatomical proximity to the left coronary system prohibited effective RF application. In 3 patients RF application resulted in a coronary spasm with complete regression as revealed in repeat coronary angiography. A relevant proportion idiopathic VT/PVC can safely be ablated from the GCV without significant permanent coronary artery stenosis after RF application. Our data furthermore demonstrate that damage to the coronary artery system is likely to be transient. © 2013.

  9. Single-stick tunneled central venous access using the jugular veins in infants weighing less than 5 kg.

    PubMed

    Lindquester, Will S; Hawkins, C Matthew; Monroe, Eric J; Gill, Anne E; Shivaram, Giridhar M; Seidel, F Glen; Lungren, Matthew P

    2017-11-01

    Despite the demonstrated feasibility of the single-stick technique in the femoral vein, its use in neonates and infants for placing central lines in internal and external jugular veins has not been reported. Describe and assess the safety and efficacy of tunneled jugular central venous catheter placement performed under ultrasound (US) and fluoroscopic guidance in neonates and infants weighing <5 kg using the single-stick technique at three tertiary pediatric hospitals. Thirty-three children weighing less than 5 kg received tunneled central venous access in either internal or external jugular veins using the single-stick technique. Patient history, procedural records and clinical follow-up documents were retrospectively reviewed. Complication rates were compared to those of 41 patients receiving single-stick femoral central lines. Technical complications occurred during one (3.0%) jugular placement with the patient having a failed right-side attempt with subsequent successful left-side placement. The catheters did not last the entire course of treatment in three (9.1%) patients with jugular lines. One patient had the catheter removed due to concern for infection, one catheter was accidentally removed during dressing changes, and one catheter was displaced and subsequently exchanged. Of patients receiving femoral central lines, 1 (2.4%) had a technical complication and 5 catheters (12.2%) did not last the entire course of treatment. The placement of tunneled central venous catheters in neonates/infants <5 kg is safe and technically feasible using the internal/external jugular vein via the single-stick technique. By theoretically reducing the risks of catheter infection by avoiding the diaper area and thrombosis by using larger veins, it may be preferable in certain patient populations.

  10. Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure.

    PubMed

    Ait-Oufella, Hafid; Boelle, Pierre-Yves; Galbois, Arnaud; Baudel, Jean-Luc; Margetis, Dimitri; Alves, Mikael; Offenstadt, Georges; Maury, Eric; Guidet, Bertrand

    2012-06-28

    Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.

  11. Catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Kirchhof, Paulus; Calkins, Hugh

    2017-01-01

    Catheter ablation is increasingly offered to patients who suffer from symptoms due to atrial fibrillation (AF), based on a growing body of evidence illustrating its efficacy compared with antiarrhythmic drug therapy. Approximately one-third of AF ablation procedures are currently performed in patients with persistent or long-standing persistent AF. Here, we review the available information to guide catheter ablation in these more chronic forms of AF. We identify the following principles: Our clinical ability to discriminate paroxysmal and persistent AF is limited. Pulmonary vein isolation is a reasonable and effective first approach for catheter ablation of persistent AF. Other ablation strategies are being developed and need to be properly evaluated in controlled, multicentre trials. Treatment of concomitant conditions promoting recurrent AF by life style interventions and medical therapy should be a routine adjunct to catheter ablation of persistent AF. Early rhythm control therapy has a biological rationale and trials evaluating its value are underway. There is a clear need to generate more evidence for the best approach to ablation of persistent AF beyond pulmonary vein isolation in the form of adequately powered controlled multi-centre trials. PMID:27389907

  12. Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.

    PubMed

    Ozmen, Evrim; Algin, Oktay

    2016-07-12

    Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.

  13. Retrieval of a subintimal fractured guide wire from the brachial artery following saphenous vein graft stenting.

    PubMed

    Danson, Edward J; Ward, Michael

    2015-06-01

    We present a case of a 58-year-old woman with diabetes mellitus with a history of angina, coronary artery bypass 24 years previously and who underwent retrieval of a fractured coronary buddy wire from the right brachial artery following attempted coronary intervention to a saphenous vein graft via the right radial route. Attempted removal of the guide wire had caused guide catheter-induced dissection of the vein graft in addition to a distal stent edge dissection before fracture in the brachial artery. The fractured end of the buddy wire was found to be in the subintimal space and could only be retrieved by advancing the wire into the subclavian artery by means of wrapping its free portion around the guiding catheter. Its fractured end could then be snared into the guiding catheter but could only be withdrawn from behind the stented segment in the vein graft by means of a trap balloon in the guiding catheter. Successful stenting of a guide catheter-induced dissection and distal stent edge dissection within the vein graft was then performed. This case highlights the hazards of deploying stents over buddy wires and of fractured guide wires in coronary intervention. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial

  15. Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.

    PubMed

    Soong, W J; Jeng, M J; Hwang, B

    1996-01-01

    A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.

  16. Risk factors associated with catheter-related upper extremity deep vein thrombosis in patients with peripherally inserted central venous catheters: a prospective observational cohort study: part 2.

    PubMed

    Maneval, Rhonda E; Clemence, Bonnie J

    2014-01-01

    This is the second part of a 2-part series that reports on the results of a prospective observational cohort study designed to examine risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters (PICCs). Part 1, published in the May/June 2014 issue of the Journal of Infusion Nursing, provided an extensive review and critique of the literature regarding risk factors associated with catheter-related UEDVT and identified 28 suspected risk factors. A study was undertaken to examine each of the risk factors among 203 acute care patients with PICCs, 13 of whom experienced a UEDVT, yielding an incidence of 6.4%. The most common reason for admission was infection (33.5%), and the primary reason for insertion of the PICC was venous access (58.6%). Hypertension (P = .022) and obesity (P = .008), defined as a body mass index ≥30, were associated with UEDVT. The clinical symptoms of edema (P < .001) and a 3-cm or more increase in arm circumference (P < .001) in the PICC arm after PICC placement were associated with UEDVT. All other variables were not statistically significant. The results suggest that patients who are obese and hypertensive may be at greater risk for the development of UEDVT and that the physical finding of edema and increased arm circumference in the PICC arm are possibly suggestive of UEDVT.

  17. A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tichelaar, Vladimir Y. I. G., E-mail: ynse.i.tichelaar@uit.no; Brodin, Ellen E.; Vik, Anders

    BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Eachmore » patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.« less

  18. Endovascular Radiofrequency Ablation for Varicose Veins

    PubMed Central

    2011-01-01

    or worse as other chronic diseases such as back pain and arthritis. Lower limb VV is a very common disease affecting adults – estimated to be the 7th most common reason for physician referral in the US. There is a very strong familial predisposition to VV. The risk in offspring is 90% if both parents affected, 20% when neither affected and 45% (25% boys, 62% girls) if one parent affected. The prevalence of VV worldwide ranges from 5% to 15% among men and 3% to 29% among women varying by the age, gender and ethnicity of the study population, survey methods and disease definition and measurement. The annual incidence of VV estimated from the Framingham Study was reported to be 2.6% among women and 1.9% among men and did not vary within the age range (40-89 years) studied. Approximately 1% of the adult population has a stasis ulcer of venous origin at any one time with 4% at risk. The majority of leg ulcer patients are elderly with simple superficial vein reflux. Stasis ulcers are often lengthy medical problems and can last for several years and, despite effective compression therapy and multilayer bandaging are associated with high recurrence rates. Recent trials involving surgical treatment of superficial vein reflux have resulted in healing and significantly reduced recurrence rates. Endovascular Radiofrequency Ablation for Varicose Veins RFA is an image-guided minimally invasive treatment alternative to surgical stripping of superficial venous reflux. RFA does not require an operating room or general anaesthesia and has been performed in an outpatient setting by a variety of medical specialties including surgeons and interventional radiologists. Rather than surgically removing the vein, RFA works by destroying or ablating the refluxing vein segment using thermal energy delivered through a radiofrequency catheter. Prior to performing RFA, color-flow Doppler ultrasonography is used to confirm and map all areas of venous reflux to devise a safe and effective

  19. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  20. Abnormal location of umbilical venous catheter due to Scimitar syndrome

    PubMed Central

    Mart, Christopher R; Van Dorn, Charlotte S

    2014-01-01

    Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705

  1. Pulmonary vein activity does not predict the outcome of catheter ablation for persistent atrial fibrillation: A long-term multicenter prospective study.

    PubMed

    Prabhu, Sandeep; Kalla, Manish; Peck, Kah Y; Voskoboinik, Aleksandr; McLellan, Alex J A; Pathik, Bupesh; Nalliah, Chrishan J; Wong, Geoff R; Sugumar, Hariharan; Azzopardi, Sonia M; Lee, Geoffrey; Ling, Liang-Han; Kalman, Jonathan M; Kistler, Peter M

    2018-03-02

    Pulmonary vein (PV) isolation (PVI) remains the cornerstone of catheter ablation (CA) in persistent atrial fibrillation (AF) (PeAF), although less successful than for paroxysmal AF. Whether rapid or fibrillatory (PV AF) PV firing may identify patients with PeAF more likely to benefit from a PV-based ablation approach is unclear. The purpose of this study was to determine the relationship between the PV cycle length (PVCL) and the PV AF outcome after CA. Before ablation, the multipolar catheter was placed in each PV and the left atrial appendage (LAA) for 100 consecutive cycles. The presence of PV AF, the average PVCL of all 4 veins (PV 4VAverage ), the fastest vein average (PV FVAverage ), the fastest cycle length (PV Fast ) both individually and relative to the average LAA cycle length were calculated. The ablation strategy included PVI and posterior wall isolation with a minimum of 12 months follow-up. A total of 123 patients underwent CA (age 62 ± 9.1 years; CHA 2 DS 2 -VASC score 1.6 ± 1.1; left ventricular ejection fraction 48% ± 13%; left atrial area 31 ± 8.7 cm 2 ; AF duration 16 ± 17 months). PVI was achieved in 100% of patients. Multiprocedure success (MPS; freedom from AF/atrial tachycardia episodes lasting >30 seconds) was achieved in 76% of patients at 24 ± 8.1 months of follow-up after 1.2 ± 0.4 procedures. PV activity was not associated with MPS either absolutely (PV 4VAverage [MPS no vs yes: 178 ± 27 ms vs 177 ± 24 ms; P = .92], PV FVAverage [P = .69], or PV Fast [P = .82]) or as a ratio relative to the LAA cycle length (PV 4VAverage /LAA 1.05 ± 0.11 vs 1.06 ± 0.21; P = .87). The presence of PV AF (31% vs 47%; P = .13) did not predict MPS. The rapidity of PV firing or presence of fibrillation within the PV was not predictive of outcome of CA for PeAF. PV activity does not identify patients most likely to benefit from a PV-based ablation strategy. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

    PubMed

    Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin

    2015-08-01

    This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.

  3. Hemodialysis Catheters: How to Keep Yours Working Well

    MedlinePlus

    ... Catheters have two openings inside; one is a red (arterial) opening to draw blood from your vein and out of your body into the dialysis pathway and the other is a blue (venous) opening that allows cleaned blood to return ...

  4. Central venous catheters: incidence and predictive factors of venous thrombosis.

    PubMed

    Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane

    2015-07-01

    Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.

  5. Catheter-related sepsis due to Rhodotorula glutinis.

    PubMed

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-02-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 microg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns.

  6. Catheter-Related Sepsis Due to Rhodotorula glutinis

    PubMed Central

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  7. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch; Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at; Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloonmore » catheter, inflating the balloon, and pulling the plug into the main right portal vein.« less

  8. New materials and devices for preventing catheter-related infections

    PubMed Central

    2011-01-01

    Catheters are the leading source of bloodstream infections for patients in the intensive care unit (ICU). Comprehensive unit-based programs have proven to be effective in decreasing catheter-related bloodstream infections (CR-BSIs). ICU rates of CR-BSI higher than 2 per 1,000 catheter-days are no longer acceptable. The locally adapted list of preventive measures should include skin antisepsis with an alcoholic preparation, maximal barrier precautions, a strict catheter maintenance policy, and removal of unnecessary catheters. The development of new technologies capable of further decreasing the now low CR-BSI rate is a major challenge. Recently, new materials that decrease the risk of skin-to-vein bacterial migration, such as new antiseptic dressings, were extensively tested. Antimicrobial-coated catheters can prevent CR-BSI but have a theoretical risk of selecting resistant bacteria. An antimicrobial or antiseptic lock may prevent bacterial migration from the hub to the bloodstream. This review discusses the available knowledge about these new technologies. PMID:21906266

  9. Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation.

    PubMed

    Lüthje, Lars; Vollmann, Dirk; Seegers, Joachim; Dorenkamp, Marc; Sohns, Christian; Hasenfuss, Gerd; Zabel, Markus

    2011-11-01

    Only limited data exist on the clinical utility of remote magnetic navigation (RMN) for pulmonary vein (PV) ablation. Aim of this prospective study was to evaluate the safety and efficacy of RMN for PV isolation as compared to the manual (CON) approach. A total of 161 consecutive patients undergoing circumferential PV isolation were included. Open-irrigated 3.5 mm ablation catheters under the guidance of a mapping system were used. The catheter was navigated with the Stereotaxis Niobe II system in the RMN group (n = 107) and guided manually in the CON group (n = 54). Electrical isolation of all PVs was achieved in 90% of the patients in the RMN group and in 87% in the CON group (p = 0.6). All subjects were followed every 3 months by 7d Holter-ECG. At 12 months of follow-up, 53.5% (RMN) and 55.5% (CON) of the patients were free of any left atrial tachycardia/atrial fibrillation (AF) episode (p = 0.57). Free of symptomatic AF recurrence were 66.3% (RMN) and 62.1% (CON) of the subjects (p = 0.80). Use of RMN was associated with longer procedure duration (p < 0.0001), ablation times (p < 0.0001), and RF current application duration (p < 0.05). In contrast, fluoroscopy time was lower in the RMN group (p < 0.0001). Major complications occurred in 6 of 161 procedures (3.7%), with no significant difference between groups (p = 0.75). RMN-guided PV ablation provides comparable acute and long-term success rates as compared to manual navigation. Procedural complication rates are similar. The use of RMN is associated with markedly reduced fluoroscopy time, but prolonged ablation and procedure duration.

  10. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices.

    PubMed

    Maurer, Tilman; Kuck, Karl-Heinz

    2017-08-01

    Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.

  11. Central vein stenosis: current concepts.

    PubMed

    Agarwal, Anil K

    2009-09-01

    Central vein stenosis (CVS) is a common complication of the central venous catheter (CVC) placement. The prevalence of CVS has mostly been studied in those who present with symptoms such as swelling of the extremity, neck and breast. CVS compromises arteriovenous access and can be resistant to treatment. A previous history of CVC placement is the most important risk factor for the development of CVS later. Pacemaker and defibrillator wires are associated with a high incidence of CVS. Increasingly liberal use of peripherally inserted central catheters (PICC) is likely to increase the incidence of CVS. The trauma and inflammation related to the catheter placement is thought to result in microthrombi formation, intimal hyperplasia and fibrotic response, with development of CVS. Treatment of CVS by endovascular procedures involves angioplasty of the stenosis. An elastic or recurrent stenosis may require a stent placement. The long-term benefits of the endovascular procedures, although improved with newer technology, remain modest. Surgical options are usually limited. Future studies to explore the pathogenesis and the use of novel therapies to prevent and treat CVS are needed. The key to reducing the prevalence of CVS is in reducing CVC placement and placement of arteriovenous accesses prior to initiating dialysis. Early referral of the patients to the nephrologists by the primary care physicians is important. Timely vein mapping and referral to the surgeon for fistula creation can obviate the need for a CVC and decrease incidence of CVS.

  12. Cost-effectiveness of additional catheter-directed thrombolysis for deep vein thrombosis.

    PubMed

    Enden, T; Resch, S; White, C; Wik, H S; Kløw, N E; Sandset, P M

    2013-06-01

    Additional treatment with catheter-directed thrombolysis (CDT) has recently been shown to reduce post-thrombotic syndrome (PTS). To estimate the cost effectiveness of additional CDT compared with standard treatment alone. Using a Markov decision model, we compared the two treatment strategies in patients with a high proximal deep vein thrombosis (DVT) and a low risk of bleeding. The model captured the development of PTS, recurrent venous thromboembolism and treatment-related adverse events within a lifetime horizon and the perspective of a third-party payer. Uncertainty was assessed with one-way and probabilistic sensitivity analyzes. Model inputs from the CaVenT study included PTS development, major bleeding from CDT and utilities for post DVT states including PTS. The remaining clinical inputs were obtained from the literature. Costs obtained from the CaVenT study, hospital accounts and the literature are expressed in US dollars ($); effects in quality adjusted life years (QALY). In base case analyzes, additional CDT accumulated 32.31 QALYs compared with 31.68 QALYs after standard treatment alone. Direct medical costs were $64,709 for additional CDT and $51,866 for standard treatment. The incremental cost-effectiveness ratio (ICER) was $20,429/QALY gained. One-way sensitivity analysis showed model sensitivity to the clinical efficacy of both strategies, but the ICER remained < $55,000/QALY over the full range of all parameters. The probability that CDT is cost effective was 82% at a willingness to pay threshold of $50,000/QALY gained. Additional CDT is likely to be a cost-effective alternative to the standard treatment for patients with a high proximal DVT and a low risk of bleeding. © 2013 International Society on Thrombosis and Haemostasis.

  13. Cost-effectiveness of additional catheter-directed thrombolysis for deep vein thrombosis

    PubMed Central

    ENDEN, T.; RESCH, S.; WHITE, C.; WIK, H. S.; KLØW, N. E.; SANDSET, P. M.

    2013-01-01

    Summary Background Additional treatment with catheter-directed thrombolysis (CDT) has recently been shown to reduce post-thrombotic syndrome (PTS). Objectives To estimate the cost effectiveness of additional CDT compared with standard treatment alone. Methods Using a Markov decision model, we compared the two treatment strategies in patients with a high proximal deep vein thrombosis (DVT) and a low risk of bleeding. The model captured the development of PTS, recurrent venous thromboembolism and treatment-related adverse events within a lifetime horizon and the perspective of a third-party payer. Uncertainty was assessed with one-way and probabilistic sensitivity analyzes. Model inputs from the CaVenT study included PTS development, major bleeding from CDT and utilities for post DVT states including PTS. The remaining clinical inputs were obtained from the literature. Costs obtained from the CaVenT study, hospital accounts and the literature are expressed in US dollars ($); effects in quality adjusted life years (QALY). Results In base case analyzes, additional CDT accumulated 32.31 QALYs compared with 31.68 QALYs after standard treatment alone. Direct medical costs were $64 709 for additional CDT and $51 866 for standard treatment. The incremental cost-effectiveness ratio (ICER) was $20 429/QALY gained. One-way sensitivity analysis showed model sensitivity to the clinical efficacy of both strategies, but the ICER remained < $55 000/QALY over the full range of all parameters. The probability that CDT is cost effective was 82% at a willingness to pay threshold of $50 000/QALY gained. Conclusions Additional CDT is likely to be a cost-effective alternative to the standard treatment for patients with a high proximal DVT and a low risk of bleeding. PMID:23452204

  14. Risk factors, management and primary prevention of thrombotic complications related to the use of central venous catheters.

    PubMed

    Linnemann, Birgit; Lindhoff-Last, Edelgard

    2012-09-01

    An adequate vascular access is of importance for the treatment of patients with cancer and complex illnesses in the intensive, perioperative or palliative care setting. Deep vein thrombosis and thrombotic occlusion are the most common complications attributed to central venous catheters in short-term and, especially, in long-term use. In this review we will focus on the risk factors, management and prevention strategies of catheter-related thrombosis and occlusion. Due to the lack of randomised controlled trials, there is still controversy about the optimal treatment of catheter-related thrombotic complications, and therapy has been widely adopted using the evidence concerning lower extremity deep vein thrombosis. Given the increasing use of central venous catheters in patients that require long-term intravenous therapy, the problem of upper extremity deep venous thrombosis can be expected to increase in the future. We provide data for establishing a more uniform strategy for preventing, diagnosing and treating catheter-related thrombotic complications.

  15. Multisensory System for the Detection and Localization of Peripheral Subcutaneous Veins

    PubMed Central

    Fernández, Roemi; Armada, Manuel

    2017-01-01

    This paper proposes a multisensory system for the detection and localization of peripheral subcutaneous veins, as a first step for achieving automatic robotic insertion of catheters in the near future. The multisensory system is based on the combination of a SWIR (Short-Wave Infrared) camera, a TOF (Time-Of-Flight) camera and a NIR (Near Infrared) lighting source. The associated algorithm consists of two main parts: one devoted to the features extraction from the SWIR image, and another envisaged for the registration of the range data provided by the TOF camera, with the SWIR image and the results of the peripheral veins detection. In this way, the detected subcutaneous veins are mapped onto the 3D reconstructed surface, providing a full representation of the region of interest for the automatic catheter insertion. Several experimental tests were carried out in order to evaluate the capabilities of the presented approach. Preliminary results demonstrate the feasibility of the proposed design and highlight the potential benefits of the solution. PMID:28422075

  16. Distal Superficial Femoral Vein Cannulation for Peripherally Inserted Central Catheter Placement in Infants with Cardiac Disease.

    PubMed

    Richter, Robert P; Law, Mark A; Borasino, Santiago; Surd, Jessica A; Alten, Jeffrey A

    2016-12-01

    To describe a novel real-time ultrasound (US)-guided distal superficial femoral vein (DSFV) cannulation technique for insertion of peripherally inserted central catheters (PICC) in critically ill infants with congenital heart disease. Descriptive retrospective cohort study SETTING: Pediatric cardiac intensive care unit in a pediatric tertiary hospital PATIENTS: First 28 critically ill infants that received DSFV PICCs via this new technique. Thirty-seven US-guided DSFV PICCs were attempted on 31 infants from September 2012 to November 2014; 34 PICCs were placed in 28 patients (success rate 92%). Twenty-six of 28 patients underwent cardiac surgery. Median (IQR) age at time of PICC placement 39 days (13, 151); weight 3.4 kg (3.2, 5.3). 25/34 PICCs were placed in patients with STAT 4 or 5 category. Median PICC duration 16 days (11, 29); maximum duration 123 days. Ten infants (36%) had DSFV PICCs placed as the primary central venous access in perioperative period. Ten of 28 patients underwent cardiac catheterization while DSFV PICC was in place, four of which were performed through ipsilateral common femoral vein. Two patients had femoral arterial lines placed in the ipsilateral femoral artery while DSFV PICC was in place. There were no reported inadvertent arterial punctures. The PICC-associated infection rate was 4.6 per 1000 line days. Four of 34 DSFV PICCs (11.8%) were associated with deep venous thrombosis. DSFV is a novel venous access site for PICC placement with high success rate and sufficient longevity and flexibility for critically ill infants with cardiac disease. More experience and larger studies are needed to confirm its potential advantages. © 2016 Wiley Periodicals, Inc.

  17. Guidewire Catheter Exchange in Pediatric Oncology: Indications, Postoperative Complications, and Outcomes.

    PubMed

    Fernandez-Pineda, I; Ortega-Laureano, L; Wu, H; Wu, J; Sandoval, J A; Rao, B N; Shochat, S J; Davidoff, A M

    2016-06-01

    Maintaining long-term central venous catheters (CVCs) in children undergoing chemotherapy can be challenging. Guidewire catheter exchange (GCE) replaces a CVC without repeat venipuncture. This study evaluated the indications, success rate, and complications of GCE in a large cohort of pediatric cancer patients. Medical records of pediatric cancer patients who underwent GCE at our institution between 2003 and 2013 were retrospectively reviewed. Variables analyzed included gender, age at GCE, primary cancer diagnosis, indication for GCE, absolute neutrophil count (ANC) at GCE, vein used, success rate, and postoperative complications (<30 days after exchange). A total of 435 GCEs performed in 407 patients (230 males and 177 females) were reviewed. Median age at GCE was 8 years (range, 0.2-24). Acute lymphoblastic leukemia was the most common diagnosis (50.6%). The primary indication for GCE was the desire to have an alternative type of CVC (71%). Other indications included catheter displacement (17%), catheter malfunction (11%), and catheter infection (1%). Median ANC at GCE was 2,581/mm(3) (range, 0-43,400). Left subclavian vein was more commonly used (57.7%). The success rate of GCE was 93.4% (406 of 435 procedures, 95% confidence interval: 91.0-97.5%). A total of 33 (7.5%) postoperative complications occurred including central line associated bloodstream infection (CLABSI) (n = 20, 4.5%), catheter dislodgement (n = 6, 1.4%), and catheter malfunction (n = 7, 1.6%). We conclude that GCE in pediatric cancer patients is associated with a high success rate and a low risk of complications. The most common postoperative complication, CLABSI, occurred at a rate significantly lower than following de novo CVC placement. © 2016 Wiley Periodicals, Inc.

  18. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    PubMed

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  19. Isolation of canine coronary sinus musculature from the atria by radiofrequency catheter ablation prevents induction of atrial fibrillation.

    PubMed

    Morita, Hiroshi; Zipes, Douglas P; Morita, Shiho T; Wu, Jiashin

    2014-12-01

    The junction between the coronary sinus (CS) musculature and both atria contributes to initiation of atrial tachyarrhythmias. The current study investigated the effects of CS isolation from the atria by radiofrequency catheter ablation on the induction and maintenance of atrial fibrillation (AF). Using an optical mapping system, we mapped action potentials at 256 surface sites in 17 isolated and arterially perfused canine atrial tissues containing the entire musculature of the CS, right atrial septum, posterior left atrium, left inferior pulmonary vein, and vein of Marshal. Rapid pacing from each site before and after addition of acetylcholine (0.5 μmol/L) was applied to induce AF. Epicardial radiofrequency catheter ablation at CS-atrial junctions isolated the CS from the atria. Rapid pacing induced sustained AF in all tissues after acetylcholine. Microreentry within the CS drove AF in 88% of preparations. Reentries associated with the vein of Marshall (29%), CS-atrial junctions (53%), right atrium (65%), and pulmonary vein (76%) (frequently with 2-4 simultaneous circuits) were additional drivers of AF. Radiofrequency catheter ablation eliminated AF in 13 tissues before acetylcholine (P<0.01) and in 5 tissues after acetylcholine. Radiofrequency catheter ablation also abbreviated the duration of AF in 12 tissues (P<0.01). CS and its musculature developed unstable reentry and AF, which were prevented by isolation of CS musculature from atrial tissue. The results suggest that CS can be a substrate of recurrent AF in patients after pulmonary vein isolation and that CS isolation might help prevent recurrent AF. © 2014 American Heart Association, Inc.

  20. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    PubMed

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  1. Relationship between peripheral insertion site and catheter-related phlebitis in adult hospitalized patients: a systematic review.

    PubMed

    Comparcini, Dania; Simonetti, Valentina; Blot, Stijn; Tomietto, Marco; Cicolini, Giancarlo

    2017-01-01

    To explore the relationship between the anatomical site of peripheral venous catheterization and risk of catheter-related phlebitis. Peripheral venous catheterization is frequently associated with phlebitis. Recent guidelines, recommend the use of an upper-extremity site for catheter insertion but no univocal consensus exists on the anatomical site with lower risk of phlebitis. Systematic review. We searched Medline (PubMed) and CINAHL (EBSCOhost) databases until the end of January 2017. We also reviewed the reference lists of retrieved articles and gray literature was excluded. Searches were limited to articles published in English with no restriction imposed to date of publication. The primary outcome was the incidence of phlebitis associated with anatomical site of peripheral catheterization. We included randomized controlled trials and observational studies on adult patients who required a peripheral catheter for the administration of medi- cation, intermittent or continuous fluid infusion. Antecubital fossa veins are associated with lower phlebitis rates, while hands veins are the most risky sites to develop phlebitis. There is no consensus regarding vein in forearm. Choosing the right anatomical site to insert a peripheral venous catheter is important to decrease phlebitis rate. Further studies should compare indwelling time in different anatomical sites with phlebitis rate. A more standardized approach in defining and assessing phlebitis among studies is recommended.

  2. Peripherally inserted central catheters in the neonatal period.

    PubMed

    Uygun, Ibrahim; Okur, Mehmet Hanifi; Otcu, Selcuk; Ozturk, Hayrettin

    2011-10-01

    Peripherally inserted central catheters (PICC) have been extensively used in neonates. However, insertion of these thinnest catheters is a very delicate procedure associated with a high failure rate. In our Neonatal Surgical Intensive Care Unit, we developed a very easy new PICC insertion and evaluated the neonates treated with PICCs which were inserted by using our technique as well as catheter features such as success rate, number of insertion attempts, reason for removal and complications. Information was retrospectively collected on all 40 PICCs inserted at Kutahya Evliya Celebi Goverment Hospital and Dicle University Hospital during a 6-years period from September 2004 to September 2010. A total of 40 PICCs were inserted in 37 patients (26, 70% males, 11, 30% females) by using new technique. The median age of patients was 8.3 days (range 1 to 66 days) and the median weight of patients was 2365 g (range 600 to 5000 g). The vein most commonly accessed was long saphenous vein (85%). The length of PICCs in the body was 19.6 cm (range 5 cm to 30 cm). The tip was located in a central vein in all patients. Surgical abdomen was the most common cause for PICC insertion (38%). Duration of catheterization was 7.7±5.6 days (1-F 5.5 days, 2-F 8.6 days). Almost all of the PICCs were inserted successfully (40/42, success rate 95%) and in the first venipucture (36/42, 86%). Completion of therapy and removed after death were achieved with 87% of PICCs. Three minor complications were noted. Minor bleeding in the insertion site which was stopped via compression occurred in two neonates. Major complication was not seen. No deaths were directly attributed to PICCs use. The new insertion technique of the neonatal peripherally inserted central catheters may be one of the easiest and safest techniques, in comparison to previous techniques reported in the literature.

  3. Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.

    PubMed

    Paik, Peter; Arukala, Sanjay K; Sule, Anupam A

    2018-01-09

    Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.

  4. [Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].

    PubMed

    Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A

    2007-10-06

    Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.

  5. Comparison of PV signal quality using a novel circular mapping and ablation catheter versus a standard circular mapping catheter.

    PubMed

    von Bary, Christian; Fredersdorf-Hahn, Sabine; Heinicke, Norbert; Jungbauer, Carsten; Schmid, Peter; Riegger, Günter A; Weber, Stefan

    2011-08-01

    Recently, new catheter technologies have been developed for atrial fibrillation (AF) ablation. We investigate the diagnostic accuracy of a circular mapping and pulmonary vein ablation catheter (PVAC) compared with a standard circular mapping catheter (Orbiter) and the influence of filter settings on signal quality. After reconstruction of the left atrium by three-dimensional atriography, baseline PV potentials (PVP) were recorded consecutively with PVAC and Orbiter in 20 patients with paroxysmal AF. PVPs were compared and attributed to predefined anatomical PV segments. Ablation was performed in 80 PVs using the PVAC. If isolation of the PVs was assumed, signal assessment of each PV was repeated with the Orbiter. If residual PV potentials could be uncovered, different filter settings were tested to improve mapping quality of the PVAC. Ablation was continued until complete PV isolation (PVI) was confirmed with the Orbiter. Baseline mapping demonstrated a good correlation between the Orbiter and PVAC. Mapping accuracy using the PVAC for mapping and ablation was 94% (74 of 79 PVs). Additional mapping with the Orbiter improved the PV isolation rate to 99%. Adjustment of filter settings failed to improve quality of the PV signals compared with standard filter settings. Using the PVAC as a stand-alone strategy for mapping and ablation, one should be aware that in some cases, different signal morphology mimics PVI isolation. Adjustment of filter settings failed to improve signal quality. The use of an additional mapping catheter is recommended to become familiar with the particular signal morphology during the first PVAC cases or whenever there is a doubt about successful isolation of the pulmonary veins.

  6. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  7. Permcath Catheter Embolization: a Case Report

    PubMed Central

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-01-01

    Introduction: Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. Case Presentation: A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. Conclusions: It is better to remove the unused devices safely to prevent and decrease their possible complications. PMID:25964881

  8. Permcath catheter embolization: a case report.

    PubMed

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-04-01

    Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. It is better to remove the unused devices safely to prevent and decrease their possible complications.

  9. Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izaki, Kenta, E-mail: izaki@med.kobe-u.ac.jp; Yamaguchi, Masato; Matsumoto, Ippei

    2011-06-15

    A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our techniquemore » for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.« less

  10. Magnetic navigation and catheter ablation of right atrial ectopic tachycardia in the presence of a hemi-azygos continuation: a magnetic navigation case using 3D electroanatomical mapping.

    PubMed

    Ernst, Sabine; Chun, Julian K R; Koektuerk, Buelent; Kuck, Karl-Heinz

    2009-01-01

    We report on a 63-year-old female patient in whom an electrophysiologic study discovered a hemi-azygos continuation. Using the magnetic navigation system, remote-controlled ablation was performed in conjunction with the 3D electroanatomical mapping system. Failing the attempt to advance a diagnostic catheter from the femoral vein, a diagnostic catheter was advanced via the left subclavian vein into the coronary sinus. The soft magnetic catheter was positioned in the right atrium via the hemi-azygos vein, and 3D mapping demonstrated an ectopic atrial tachycardia. Successful ablation was performed entirely remote controlled. Fluoroscopy time was only 7.1 minutes, of which 45 seconds were required during remote navigation. Remote-controlled catheter ablation using magnetic navigation in conjunction with the electroanatomical mapping system proved to be a valuable tool to perform successful ablation in the presence of a hemi-azygos continuation.

  11. Use of intraoperative venography to guide the distal portion of a ventriculoatrial shunt past an obstruction in the central veins: technical case report.

    PubMed

    Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele

    2010-06-01

    Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.

  12. Quantifying and correcting for tail vein extravasation in small animal PET scans in cancer research: is there an impact on therapy assessment?

    PubMed

    Lasnon, Charline; Dugué, Audrey Emmanuelle; Briand, Mélanie; Dutoit, Soizic; Aide, Nicolas

    2015-12-01

    Tail vein injection under short anesthesia is the most commonly used route for administering radiopharmaceuticals. However, the small caliber of the vein in rodents may lead to tracer extravasation and thereby compromise quantitative accuracy of PET. We aimed to evaluate a method for correction of interstitial radiotracer leakage in the context of pre-clinical therapeutic response assessment. In two separate studies involving 16 nude rats, a model of human ovarian cancer was xenografted and each was treated with a Phosphoinositide 3-kinase/mammalian target of rapamycin inhibitor or used as a control. Tracer injections were performed via the tail vein by a single operator. Two observers qualitatively evaluated the resulting images and if appropriate drew a volume of interest (VOI) over the injection site to record extravasated activities. Uncorrected and corrected tumors' mean standardized uptake value (SUV)mean was computed (corrected injected activity = calibrated activity - decay corrected residual syringe activity - decay corrected tail extravasated activity). Molecular analyses were taken as a gold standard. The frequency and magnitude of extravasation were analyzed, as well as the inter-observer agreement and the impact of the correction method on tumor uptake quantification. Extravasation never exceeded 20 % of the injected dose but occurred in more than 50 % of injections. It was independent of groups of animals and protocol time points with p values of 1.00 and 0.61, respectively, in the first experiment and 0.47 and 0.13, respectively, in the second experiment. There was a good inter-observer agreement for qualitative analysis (kappa = 0.72) and a moderate agreement when using quantitative analysis (ρ c = 0.94). In both experiments, there was significant difference between uncorrected and corrected SUVmean. Despite this significant difference, mean percent differences between uncorrected and corrected SUVmean in the first and the second

  13. Endovascular interventions for central vein stenosis.

    PubMed

    Agarwal, Anil K

    2015-12-01

    Central vein stenosis is common because of the placement of venous access and cardiac intravascular devices and compromises vascular access for dialysis. Endovascular intervention with angioplasty and/or stent placement is the preferred approach, but the results are suboptimal and limited. Primary patency after angioplasty alone is poor, but secondary patency can be maintained with repeated angioplasty. Stent placement is recommended for quick recurrence or elastic recoil of stenosis. Primary patency of stents is also poor, though covered stents have recently shown better patency than bare metal stents. Secondary patency requires repeated intervention. Recanalization of occluded central veins is tedious and not always successful. Placement of hybrid graft-catheter with a combined endovascular surgical approach can maintain patency in many cases. In the presence of debilitating symptoms, palliative approach with endovascular banding or occlusion of the access may be necessary. Prevention of central vein stenosis is the most desirable strategy.

  14. Comparison of catheter-related large vein thrombosis in centrally inserted versus peripherally inserted central venous lines in the neurological intensive care unit.

    PubMed

    Wilson, Thomas J; Stetler, William R; Fletcher, Jeffrey J

    2013-07-01

    To compare cumulative complication rates of peripherally (PICC) and centrally (CICVC) inserted central venous catheters, including catheter-related large vein thrombosis (CRLVT), central line-associated bloodstream infection (CLABSI), and line insertion-related complications in neurological intensive care patients. Retrospective cohort study and detailed chart review for 431 consecutive PICCs and 141 CICVCs placed in patients under neurological intensive care from March 2008 through February 2010. Cumulative incidence of CRLVT, CLABSI, and line insertion-related complications were compared between PICC and CICVC groups. Risk factors for CRLVT including mannitol therapy during dwell time, previous history of venous thromboembolism, surgery longer than 1h during dwell time, and line placement in a paretic arm were also compared between groups. During the study period, 431 unique PICCs were placed with cumulative incidence of symptomatic thrombosis of 8.4%, CLABSI 2.8%, and line insertion-related complications 0.0%. During the same period, 141 unique CICVCs were placed with cumulative incidence of symptomatic thrombosis of 1.4%, CLABSI 1.4%, and line insertion-related complications 0.7%. There was a statistically significant difference in CRLVT with no difference in CLABSI or line insertion-related complications. In neurological critical care patients, CICVCs appear to have a better risk profile compared to PICCs, with a decreased risk of CRLVT. As use of PICCs in critical care patients increases, a prospective randomized trial comparing PICCs and CICVCs in neurological critical care patients is necessary to assist in choosing the appropriate catheter and to minimize risks of morbidity and mortality associated with central venous access. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates

    PubMed Central

    Merchaoui, Zied; Lausten-Thomsen, Ulrik; Pierre, Florence; Ben Laiba, Maher; Le Saché, Nolwenn; Tissieres, Pierre

    2017-01-01

    The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subclavian vein (SCV) has been described in children and neonates. This article gives an overview of the current use of US for achieving central venous catheter placement in the SCV or the brachiocephalic vein (BCV) in neonates. More than 1,250 catheters have been reported inserted in children and neonates for a cumulated success rate of 98.4% and the complication rate is reported to be low. The technical aspects of various approaches are discussed, and we offer our recommendation of an US-guided technique for SCV and BCV cannulation based on our experience in a large NICU setting. Although the cannulation the SCV or BCV does not substitute the use of peripherally inserted central catheters or umbilical venous central catheters in neonates, it is a feasible route in very small children who are in need of a large caliber central venous access. PMID:29051889

  16. Long-term outcome of permanent hemodialysis catheters: a controlled study.

    PubMed

    Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M

    2001-01-01

    Hemodialysis tunneled catheters are widely used nowadays. However, their complications, infection and dysfunction, remain much too frequent. Different types of tunneled silicone hemodialysis catheters are available. We prospectively compared the long-term outcome of the two most popular devices, Permcath cuffed double catheter and TwinCath uncuffed twin catheter, both inserted percutaneously. From January 1994 to April 1998, 125 tunneled catheters were inserted in the internal jugular vein of 86 chronic hemodialysis patients, 63 TwinCath MedComp (TC) and 62 Permcath Quinton (PC). They were prospectively followed looking for technical patency, infection and dysfunction rate. TC were used more often for iterative access (52 vs. 25%, p = 0.01) and were inserted more frequently in the left internal jugular vein (59 vs. 16% p < 0.001). Their median technical survival rate was longer (869 vs. 433 days for PC, p < 0.01) with a 1-year patency rate of 80 vs. 53% (p = 0.002). Total catheter extrusion was also slightly less frequent with TC (4.7 vs. 9.6%), but partial extrusion happened more frequently (43 vs. 16%, p = 0.02). No significant difference in infection rate was observed, 0.77 for TC vs. 1.3 local infection/1,000 catheter days; 1.08 vs. 1.30 bacteremia/1,000 catheter days. A persistent catheter thrombosis was observed in 7.9 vs. 20.9% in PC (p = 0.04), the number of dysfunction was 10.5 vs. 24/1,000 days in use (p = 0.0001) and the number of urokinase infusion was 4.4 vs. 12/1,000 days (p = 0.001). PC needed more radiological interventions for dysfunction with endolumenal brushes (4 vs. 0) or fibrin sleeve removal (4 vs. 0). The vena cava thrombosis incidence was not different (2 vs. 3). Although the study was not randomized, TC appears more efficient allowing for a longer patency with a lower dysfunction rate than PC. This was reinforced by less favorable conditions of TC including more left jugular side and more iterative catheters. The cuff does not offer a

  17. Iliopsoas abscess as a complication of tunneled jugular vein catheterization in a hemodialysis patient.

    PubMed

    Hsiao, Po-Jen; Tsai, Ming-Hsien; Leu, Jyh-Gang; Fang, Yu-Wei

    2015-04-01

    Iliopsoas abscess is a rare complication in hemodialysis patients that is mainly due to adjacent catheterization, local acupuncture, discitis, and bacteremia. Herein, we report a 47-year-old woman undergoing regular hemodialysis via a catheter in the internal jugular vein who presented with low back pain and dyspnea. A heart murmur suggested the presence of catheter-related endocarditis, and this was confirmed by an echocardiogram and a blood culture of methicillin-resistant Staphylococcus aureus. A computed tomography indicated a pulmonary embolism and an incidental finding of iliopsoas abscess. Following surgical intervention and intravenous daptomycin, the patient experienced full recovery and a return to usual activities. This case indicates that an iliopsoas abscess can be related to a jugular vein catheter, which is apparently facilitated by infective endocarditis. The possibility of iliopsoas abscess should be considered when a hemodialysis patient presents with severe low back pain, even when there is no history of adjacent mechanical intervention. © 2014 International Society for Hemodialysis.

  18. Strict sequential catheter ablation strategy targeting the pulmonary veins and superior vena cava for persistent atrial fibrillation.

    PubMed

    Yoshiga, Yasuhiro; Shimizu, Akihiko; Ueyama, Takeshi; Ono, Makoto; Fukuda, Masakazu; Fumimoto, Tomoko; Ishiguchi, Hironori; Omuro, Takuya; Kobayashi, Shigeki; Yano, Masafumi

    2018-08-01

    An effective catheter ablation strategy, beyond pulmonary vein isolation (PVI), for persistent atrial fibrillation (AF) is necessary. Pulmonary vein (PV)-reconduction also causes recurrent atrial tachyarrhythmias. The effect of the PVI and additional effect of a superior vena cava (SVC) isolation (SVCI) was strictly evaluated. Seventy consecutive patients with persistent AF who underwent a strict sequential ablation strategy targeting the PVs and SVC were included in this study. The initial ablation strategy was a circumferential PVI. A segmental SVCI was only applied as a repeat procedure when patients demonstrated no PV-reconduction. After the initial procedure, persistent AF was suppressed in 39 of 70 (55.7%) patients during a median follow-up of 32 months. After multiple procedures, persistent AF was suppressed in 46 (65.7%) and 52 (74.3%) patients after receiving the PVI alone and PVI plus SVCI strategies, respectively. In 6 of 15 (40.0%) patients with persistent AF resistant to PVI, persistent AF was suppressed. The persistent AF duration independently predicted persistent AF recurrences after multiple PVI alone procedures [HR: 1.012 (95% confidence interval: 1.006-1.018); p<0.001] and PVI plus SVCI strategies [HR: 1.018 (95% confidence interval: 1.011-1.025); p<0.001]. A receiver-operating-characteristic analysis for recurrent persistent AF indicated an optimal cut-off value of 20 and 32 months for the persistent AF duration using the PVI alone and PVI plus SVCI strategies, respectively. The outcomes of the PVI plus SVCI strategy were favorable for patients with shorter persistent AF durations. The initial SVCI had the additional effect of maintaining sinus rhythm in some patients with persistent AF resistant to PVI. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  19. Interventional Therapy for Upper Extremity Deep Vein Thrombosis

    PubMed Central

    Carlon, Timothy A.; Sudheendra, Deepak

    2017-01-01

    Approximately 10% of all deep vein thromboses occur in the upper extremity, and that number is increasing due to the use of peripherally inserted central catheters. Sequelae of upper extremity deep vein thrombosis (UEDVT) are similar to those for lower extremity deep vein thrombosis (LEDVT) and include postthrombotic syndrome and pulmonary embolism. In addition to systemic anticoagulation, there are multiple interventional treatment options for UEDVT with the potential to reduce the incidence of these sequelae. To date, there have been no randomized trials to define the optimal management strategy for patients presenting with UEDVT, so many conclusions are drawn from smaller, single-center studies or from LEDVT research. In this article, the authors describe the evidence for the currently available treatment options and an approach to a patient with acute UEDVT. PMID:28265130

  20. Extravasation from venous catheter: a serious complication potentially missed by lung imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spicer, K.M.; Gordon, L.

    Three patients were referred for lung ventiliation and perfusion (V/Q) imaging with symptoms strongly suggestive of pulmonary embolus (PE). Chest roentgenograms and xenon ventilation studies on all three were normal, save for prominent mediastinal silhouettes and effusions. Technetium-99m macroaggregated albumin(Tc-99m MAA), when injected through the central venous catheter (CVP), revealed mediastinal localization, whereas antecubital injections showed normal pulmonary perfusion. Contrast fluoroscopy introduced through the venous catheter in the first patient defined the extravasation. For patients under strong suspicion of PE, with a venous catheter whose distal tip is seen about the level of the heart on chest radiograph, the authorsmore » recommend administering the perfusion agent slowly through the central catheter to exclude catheter-induced complications. When extravasation is detected, injection of Tc-99m MAA by peripheral vein should be used to exclude PE.« less

  1. Rare malposition following left jugular vein catheterization: Case reports and a literature review.

    PubMed

    Wang, Lin; Liu, Zhangsuo; Wang, Changan; Liu, Dongwei; Yuan, Yiqiang

    2015-01-01

    The number of patients requiring chronic hemodialysis via a tunneled cuffed catheter is increasing. The right internal jugular vein (IJV) is generally the preferred site of percutaneous insertion. In certain situations, for example, in patients with a history of multiple access failures, catheterization of the left IJV is an important option. In this report, we present two rare cases of catheter malposition after left IJV catheterization; catheter adjustments, with the help of chest radiographs, resulted in a positive outcome in both cases. These cases exemplify the difficulties associated with left IJV catheterization, of which there are few reports in the published literature.

  2. Optimization of left adrenal vein sampling in primary aldosteronism: Coping with asymmetrical cortisol secretion.

    PubMed

    Kishino, Mitsuhiro; Yoshimoto, Takanobu; Nakadate, Masashi; Katada, Yoshiaki; Kanda, Eiichiro; Nakaminato, Shuichiro; Saida, Yukihisa; Ogawa, Yoshihiro; Tateishi, Ukihide

    2017-03-31

    We evaluated the influence of catheter sampling position and size on left adrenal venous sampling (AVS) in patients with primary aldosteronism (PA) and analyzed their relationship to cortisol secretion. This retrospective study included 111 patients with a diagnosis of primary aldosteronism who underwent tetracosactide-stimulated AVS. Left AVS was obtained from two catheter positions - the central adrenal vein (CAV) and the common trunk. For common trunk sampling, 5-French catheters were used in 51 patients, and microcatheters were used in 60 patients. Autonomous cortisol secretion was evaluated with a low-dose dexamethasone suppression test in 87 patients. The adrenal/inferior vena cava cortisol concentration ratio [selectivity index (SI)] was significantly lower in samples from the left common trunk than those of the left CAV and right adrenal veins, but this difference was reduced when a microcatheter was used for common trunk sampling. Sample dilution in the common trunk of the left adrenal vein can be decreased by limiting sampling speed with the use of a microcatheter. Meanwhile, there was no significant difference in SI between the left CAV and right adrenal veins. Laterality, determined according to aldosterone/cortisol ratio (A/C ratio) based criteria, showed good reproducibility regardless of sampling position, unlike the absolute aldosterone value based criteria. However, in 11 cases with autonomous cortisol co-secretion, the cortisol hypersecreting side tended to be underestimated when using A/C ratio based criteria. Left CAV sampling enables symmetrical sampling, and may be essential when using absolute aldosterone value based criteria in cases where symmetrical cortisol secretion is uncertain.

  3. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.

    PubMed

    Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y

    2004-03-01

    Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.

  4. Factor v leiden mutation in patients with breast cancer with a central venous catheter: risk of deep vein thrombosis.

    PubMed

    Curigliano, Giuseppe; Mandalà, Mario; Sbanotto, Alberto; Colleoni, Marco; Ferretti, Gianluigi; Bucciarelli, Paolo; Peruzzotti, Giulia; de Braud, Filippo; De Pas, Tommaso; Spitaleri, Gianluca; Pietri, E; Orsi, Franco; Banfi, Maria G; Goldhirsch, Aron

    2006-01-01

    The objective of this study was to analyze the influence of the prothrombotic factor V Leiden (FVL) and G20210A prothrombin mutations on the frequency of the first episode of catheter-related deep vein thrombosis (DVT) in a cohort of patients with locally advanced or metastatic breast cancer during continuous venous insult (infusion of 5-fluorouracil-based chemotherapy). Between January 1999 and February 2001, we retrospectively analyzed the incidence of first DVT in 300 consecutive patients with locally advanced or metastatic breast cancer treated at a single institution with a combination of chemotherapy administered continuously through a totally implanted access port. We identified 25 women (study group) with catheter-related DVT. For each of the 25 patients, we selected 2 women eligible for identical chemotherapy who had similar age, stage of disease, and prognostic features as a control group. The prothrombotic FVL and prothrombin mutation G20210A genotype analyses were performed in all patients. Analyses were performed on blinded samples, and all patients signed a specific informed consent form. A total of 25 cases (with thrombosis) and 50 frequency-matched controls were evaluated for FVL. Five cases and 2 controls were found with the mutation in the FVL, for incidences of 20% (95% CI, 9%-39%) and 4% (95% CI, 1%-14%), respectively. Thus, the frequency of the mutation was significantly higher in the cases than in controls (P = 0.04), and a logistic regression analysis, adjusted by age, yielded an odds ratio of 6.1 (95% CI, 1.1%-34.3%; P = 0.04). Time from start of infusion chemotherapy to thrombosis was not significantly different between those with the mutation (median, 31 days) and without the mutation (median, 43 days; P = 0.6). Only 1 subject (in the case group) was found with the G20210A mutation in the prothrombin gene. Factor V Leiden carriers with locally advanced or metastatic breast cancer are at high risk of catheter-related DVT during chemotherapy

  5. Intra-arterial catheter system to repeatedly deliver mesenchymal stem cells in a rat renal failure model.

    PubMed

    Katsuoka, Yuichi; Ohta, Hiroki; Fujimoto, Eisuke; Izuhara, Luna; Yokote, Shinya; Kurihara, Sho; Yamanaka, Shuichiro; Tajiri, Susumu; Chikaraish, Tatsuya; Okano, Hirotaka J; Yokoo, Takashi

    2016-04-01

    Mesenchymal stem cell therapy in renal failure is rarely used because of low rates of cell engraftment after systemic delivery. Repeated intra-arterial cell administration may improve results; however, no current delivery method permits repeated intra-arterial infusions in a rat model. In this study, we developed an intra-arterial delivery system for repeated stem cell infusion via the aorta, catheterizing the left femoral artery to the suprarenal aorta under fluoroscopic guidance in rats with adenosine-induced renal failure. First, we compared our intra-arterial catheter system (C group, n = 3) with tail vein injection (V group, n = 3) for engraftment efficacy, using mesenchymal stem cells from luciferase transgenic rats. Rats were infused with the cells and euthanized the following day; we performed cell-tracking experiments using a bioluminescence imaging system to assess the distribution of the infused cells. Second, we assessed the safety of the system over a 30-day period in a second group of six rats receiving infusions every 7 days. Cells infused through our delivery system efficiently engrafted into the kidney, compared with peripheral venous infusion. In five of the six rats in the safety study, the delivery system remained patent for at least 9 days (range, 9-24 days). Complications became evident only after 10 days. Our intra-arterial catheter system was effective in delivering cells to the kidney and permitted repeated injection of cells.

  6. Difficulties of Distal Catheter Insertion of Ventriculoatrial Shunting in Infants and Little Children.

    PubMed

    Erdogan, Hakan; Altun, Adnan; Kuruoglu, Enis; Kaya, Ahmet Hilmi; Dagcinar, Adnan

    2017-09-26

    Ventriculoatrial (VA) shunting is a well-described cerebrospinal fluid diversion method for the treatment of hydrocephalus. However, it may be very challenging in infants and little children because of atrial catheter placement difficulties. This study aimed to create an algorithm to solve problems faced during open surgical procedures based on the present authors' experience. We conducted a retrospective analysis on 18 infants and children who underwent VA shunt insertion at the Department of Neurosurgery, Ondokuz Mayıs University School of Medicine Hospital between 2005 and 2012. Complications, clinical outcomes, revisions, and solutions for overcoming distal catheter placement difficulties were evaluated. Twenty-six VA shunt operations were performed in 18 patients. Six patients required eight VA shunt revisions. VA shunting was primarily performed from the internal jugular, facial, cephalic, and subclavian veins to the right atrium. In revision procedures, the internal jugular, cephalic, and subclavian veins were used. VA shunting in infants and little children requires careful surgical techniques. Neurosurgeons should necessarily have an appropriate strategy for VA shunting considering the complications and revisions. Our results suggest open surgical solutions to overcome distal catheter placement difficulties in this age group.

  7. Port in oncology practice: 3-monthly locking with normal saline for catheter maintenance, a preliminary report.

    PubMed

    Solinas, Gianfranca; Platini, Francesca; Trivellato, Maurizio; Rigo, Carla; Alabiso, Oscar; Galetto, Alessandra S

    2017-07-14

    Patients with cancer need stable venous access using central vascular devices like central venous ports and peripherally inserted central catheters that can be used for a wide range of indications. Numerous flushing protocols exist including different frequencies for catheter locking to maintain catheter patency. The aim of this retrospective study was to evaluate the incidence of lumen occlusion of central venous ports in a group of adult cancer patients, adopting a policy of locking with normal saline every three months. This is a single-center retrospective observational study. During follow-up, we analyzed adult cancer patients who had undergone port insertion from January 1st, 2007 to August 31st, 2014. Flushing and locking were performed every three months with a syringe containing normal saline. We collected data from 381 patients with ports inserted in subclavian vein (379 patients) and in the right jugular vein (2 patients). Locking was performed during 3-monthly follow-up visits. Median follow-up was 810 days (90-2700 days). Among 381 ports, 59 were removed; the reasons for removal were: end of use (45 cases), catheter rupture (9 cases), dislocation (3 cases) and catheter-related bloodstream infection (2 cases). We had no reports of lumen occlusion. Our data suggest that locking ports with normal saline every three months is not associated with an increased risk of lumen occlusion.

  8. Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters

    PubMed Central

    Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119

  9. Trans-Splenic Portal Vein Embolization: A Technique to Avoid Damage to the Future Liver Remnant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarwar, Ammar, E-mail: asarwar@bidmc.harvard.edu; Brook, Olga R.; Weinstein, Jeffrey L.

    2016-10-15

    Portal vein embolization (PVE) induces hypertrophy of the future liver remnant (FLR) in patients undergoing extensive hepatic resection. Portal vein access for PVE via the ipsilateral hepatic lobe (designated for resection) places veins targeted for embolization at acute angles to the access site requiring reverse curve catheters for access. This approach also involves access close to tumors in the ipsilateral lobe and requires care to avoid traversing tumor. Alternatively, a contralateral approach (through the FLR) risks damage to the FLR due to iatrogenic trauma or non-target embolization. Two patients successfully underwent PVE via trans-splenic portal vein access, allowing easy accessmore » to the ipsilateral portal veins and eliminating risk of damage to FLR. Technique and advantages of trans-splenic portal vein access to perform PVE are described.« less

  10. Hemodialysis tunneled central venous catheters: five-year outcome analysis.

    PubMed

    Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea

    2014-01-01

    Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.

  11. Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs.

    PubMed

    Morishita, Keitaro; Hiramoto, Akira; Michishita, Asuka; Takagi, Satoshi; Hoshino, Yuki; Itami, Takaharu; Lim, Sue Yee; Osuga, Tatsuyuki; Nakamura, Sayuri; Ochiai, Kenji; Nakamura, Kensuke; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2017-04-01

    OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.

  12. Approaches to catheter ablation for persistent atrial fibrillation.

    PubMed

    Verma, Atul; Jiang, Chen-yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan

    2015-05-07

    Catheter ablation is less successful for persistent atrial fibrillation than for paroxysmal atrial fibrillation. Guidelines suggest that adjuvant substrate modification in addition to pulmonary-vein isolation is required in persistent atrial fibrillation. We randomly assigned 589 patients with persistent atrial fibrillation in a 1:4:4 ratio to ablation with pulmonary-vein isolation alone (67 patients), pulmonary-vein isolation plus ablation of electrograms showing complex fractionated activity (263 patients), or pulmonary-vein isolation plus additional linear ablation across the left atrial roof and mitral valve isthmus (259 patients). The duration of follow-up was 18 months. The primary end point was freedom from any documented recurrence of atrial fibrillation lasting longer than 30 seconds after a single ablation procedure. Procedure time was significantly shorter for pulmonary-vein isolation alone than for the other two procedures (P<0.001). After 18 months, 59% of patients assigned to pulmonary-vein isolation alone were free from recurrent atrial fibrillation, as compared with 49% of patients assigned to pulmonary-vein isolation plus complex electrogram ablation and 46% of patients assigned to pulmonary-vein isolation plus linear ablation (P=0.15). There were also no significant differences among the three groups for the secondary end points, including freedom from atrial fibrillation after two ablation procedures and freedom from any atrial arrhythmia. Complications included tamponade (three patients), stroke or transient ischemic attack (three patients), and atrioesophageal fistula (one patient). Among patients with persistent atrial fibrillation, we found no reduction in the rate of recurrent atrial fibrillation when either linear ablation or ablation of complex fractionated electrograms was performed in addition to pulmonary-vein isolation. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT01203748.).

  13. Cigarette smoking causes a worse long-term outcome in persistent atrial fibrillation following catheter ablation.

    PubMed

    Cheng, Wen-Han; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Hung, Yuan; Chung, Fa-Po; Chang, Ting-Yung; Huang, Ting-Chung; Yamada, Shinya; Salim, Simon; Te, Abigail Louise D; Liao, Jo-Nan; Tuan, Ta-Chuan; Chao, Tze-Fan; Tsai, Tseng-Ying; Liu, Shin-Huei; Chen, Shih-Ann

    2018-02-09

    Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium. © 2018 Wiley Periodicals, Inc.

  14. Consensus for the Treatment of Varicose Vein with Radiofrequency Ablation

    PubMed Central

    Joh, Jin Hyun; Kim, Woo-Shik; Jung, In Mok; Park, Ki-Hyuk; Lee, Taeseung; Kang, Jin Mo

    2014-01-01

    The objective of this paper is to introduce the schematic protocol of radiofrequency (RF) ablation for the treatment of varicose veins. Indication: anatomic or pathophysiologic indication includes venous diameter within 2–20 mm, reflux time ≥0.5 seconds and distance from the skin ≥5 mm or subfascial location. Access: it is recommended to access at or above the knee joint for great saphenous vein and above the mid-calf for small saphenous vein. Catheter placement: the catheter tip should be placed 2.0 cm inferior to the saphenofemoral or saphenopopliteal junction. Endovenous heat-induced thrombosis ≥class III should be treated with low-molecular weight heparin. Tumescent solution: the composition of solution can be variable (e.g., 2% lidocaine 20 mL+500 mL normal saline+bicarbonate 2.5 mL with/without epinephrine). Infiltration can be done from each direction. Ablation: two cycles’ ablation for the first proximal segment of saphenous vein and the segment with the incompetent perforators is recommended. The other segments should be ablated one time. During RF energy delivery, it is recommended to apply external compression. Concomitant procedure: It is recommended to do simultaneously ambulatory phlebectomy. For sclerotherapy, it is recommended to defer at least 2 weeks. Post-procedural management: post-procedural ambulation is encouraged to reduce the thrombotic complications. Compression stocking should be applied for at least 7 days. Minor daily activity is not limited, but strenuous activities should be avoided for 2 weeks. It is suggested to take showers after 24 hours and tub baths, swimming, or soaking in water after 2 weeks. PMID:26217628

  15. Risk factor analysis for long-term tunneled dialysis catheter-related bacteremias.

    PubMed

    Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M; Laurent, G

    2002-07-01

    Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors. Copyright 2002 S. Karger AG, Basel

  16. Antimicrobial Efficacy of a New Chlorhexidine-based Device Against Staphylococcus aureus Colonization of Venous Catheters

    PubMed Central

    Kowalewska, Paulina M.; Petrik, Shawn M.; Di Fiore, Attilio E.; Fox-Robichaud, Alison E.

    2018-01-01

    Vascular catheters are a major cause of nosocomial bloodstream infections. ChloraLock (ATTWILL Medical Solutions, Inc, West Jordan, UT, and ICU Medical, Inc, San Clemente, CA) is a novel antimicrobial device containing chlorhexidine digluconate (CHG) that is fitted onto a syringe and infuses CHG into the catheter lumen during locking. The objective of this study was to evaluate the antimicrobial efficacy of ChloraLock with in vitro tests and its ability to reduce Staphylococcus aureus contamination of catheters in the external jugular veins of Yorkshire swine. ChloraLock significantly reduced the bacterial load in the in vitro tests by up to 6 log10 colony-forming units (CFU) and by 3 to 4 log10 CFU/lumen in vivo in a swine model with 0.9% NaCl catheter locks. PMID:29489705

  17. Antimicrobial Efficacy of a New Chlorhexidine-based Device Against Staphylococcus aureus Colonization of Venous Catheters.

    PubMed

    Kowalewska, Paulina M; Petrik, Shawn M; Di Fiore, Attilio E; Fox-Robichaud, Alison E

    Vascular catheters are a major cause of nosocomial bloodstream infections. ChloraLock (ATTWILL Medical Solutions, Inc, West Jordan, UT, and ICU Medical, Inc, San Clemente, CA) is a novel antimicrobial device containing chlorhexidine digluconate (CHG) that is fitted onto a syringe and infuses CHG into the catheter lumen during locking. The objective of this study was to evaluate the antimicrobial efficacy of ChloraLock with in vitro tests and its ability to reduce Staphylococcus aureus contamination of catheters in the external jugular veins of Yorkshire swine. ChloraLock significantly reduced the bacterial load in the in vitro tests by up to 6 log10 colony-forming units (CFU) and by 3 to 4 log10 CFU/lumen in vivo in a swine model with 0.9% NaCl catheter locks.

  18. Central vein perforation during tunneled dialysis catheter insertion: principles of acute management.

    PubMed

    Pua, Uei

    2014-10-01

    Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.

  19. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    PubMed

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  20. Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).

    PubMed

    Head, Valerie; Eshar, David; Nau, Melissa R

    2017-03-01

    Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.

  1. Minimally Invasive Monitoring of Chronic Central Venous Catheter Patency in Mice Using Digital Subtraction Angiography (DSA)

    PubMed Central

    Figueiredo, Giovanna; Fiebig, Teresa; Kirschner, Stefanie; Nikoubashman, Omid; Kabelitz, Lisa; Othman, Ahmed; Nonn, Andrea; Kramer, Martin; Brockmann, Marc A.

    2015-01-01

    Background Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. Methods Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 μL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 μL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. Results DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. Conclusion From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice. PMID:26098622

  2. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters

  3. Changing profile of excimer laser coronary angioplasty: refinements in catheters

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1994-07-01

    During more than five years of investigation with excimer laser angioplasty, several changes have been made in patient selection and laser catheters. It is unclear, however, whether these changes have improved the outcome of excimer laser angioplasty. A total of 2041 patients underwent treatment with excimer laser coronary angioplasty for 2324 lesions with clinical success in 89%, ischemic complications in 7.5%, and vessel perforation in 2.1%. When the entire 5-year period of investigation was divided into four discrete phases, as defined by the successive release of improved laser catheters (prototype, flexible, extremely flexible, and eccentric), clinical success was seen to improve from 86% to 95% (p<0.001) despite the increased incidence of advanced age (pequals0.01) and unstable angina (p<0.001). Multivariable analysis identified improved laser catheters, saphenous vein graft lesions, and unclarified stenoses as predictors of favorable outcome. Operator experience was associated with decreased complications. Reduced catheter size relative to vessel size was associated with decreased risk of vessel perforation. Thus, refinements in patient selection and in laser technique have been associated with enhanced safety and efficacy of excimer laser angioplasty.

  4. Effects of Axial Vibration on Needle Insertion into the Tail Veins of Rats and Subsequent Serial Blood Corticosterone Levels

    PubMed Central

    Clement, Ryan S; Unger, Erica L; Ocón-Grove, Olga M; Cronin, Thomas L; Mulvihill, Maureen L

    2016-01-01

    Blood collection is commonplace in biomedical research. Obtaining sufficient sample while minimizing animal stress requires significant skill and practice. Repeated needle punctures can cause discomfort and lead to variable release of stress hormones, potentially confounding analysis. We designed a handheld device to reduce the force necessary for needle insertion by using low-frequency, axial (forward and backward) micromotions (that is, vibration) delivered to the needle during venipuncture. Tests with cadaver rat-tail segments (n = 18) confirmed that peak insertion forces were reduced by 73% on average with needle vibration. A serial blood-sampling study was then conducted by using Sprague–Dawley rats divided into 2 groups based on needle condition used to cause bleeds: vibration on (n = 10) and vibration off (n = 9). On 3 days (1 wk apart), 3 tail-vein blood collections were performed in each subject at 1-h intervals. To evaluate associated stress levels, plasma corticosterone concentration was quantified by radioimmunoassay and behavior (that is, movement and vocalization) was scored by blinded review of blood-sampling videos. After the initial trial, average corticosterone was lower (46% difference), the mean intrasubject variance trended lower (72%), and behavioral indications of stress were rated lower for the vibration-on group compared with the vibration-off group. Adding controlled vibrations to needles during insertion may decrease the stress associated with blood sampling from rats—an important methodologic advance for investigators studying and assessing stress processes and a refinement over current blood sampling techniques. PMID:27025813

  5. Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation.

    PubMed

    Sohns, Christian; Bergau, Leonard; Seegers, Joachim; Lüthje, Lars; Vollmann, Dirk; Zabel, Markus

    2014-10-01

    In ablation of atrial fibrillation, the single-ring method aims for isolation of the posterior wall of the left atrium (LA) including the pulmonary veins (PVs) but avoiding posterior LA lesions. The aim of this randomized prospective study was to evaluate safety and efficacy of remote magnetic navigation (RMN)-guided single-ring ablation strategy as compared to standard RMN-guided circumferential PV ablation (PVA). Eighty consecutive patients undergoing PVA were enrolled prospectively and randomized equally into two study groups. RMN using the Stereotaxis system and open-irrigated 3.5-mm ablation catheters were used with a 3D mapping system in all procedures. Forty patients underwent RMN-guided single-ring ablation, and 40 patients received RMN-guided circumferential PVA. In the circumferential group, 3.3 ± 1.1 PVs were successfully isolated at the end of the procedure as compared to 3.1 ± 1.3 in the single-ring (box) group (p=0.38). All patients in the box group required additional posterior lesions in order to achieve electrical isolation of the PVs. Single-ring ablation was associated with longer procedure duration (p=0.01) and ablation time (p=0.001). After a single procedure, the proportion of patients free of any atrial tachycardia (AT)/atrial fibrillation (AF) episode at 12-month follow-up was 57 % in the box group and 58 % in the circ group. Using RMN, only minor complications have been observed. RMN-guided single-ring PVA provides comparable acute and long-term success rates as compared to RMN-guided circumferential PVA but requires additional posterior lesions to achieve PV isolation and increased procedure and ablation time. Procedural complication rates are low when using RMN.

  6. An umbilical venous catheter complication presented as acute abdomen: case report.

    PubMed

    Oztan, Mustafa O; Ilhan, Ozkan; Abay, Elif; Koyluoglu, Gokhan

    2016-12-01

    Umbilical venous catheterization has become a widely accepted intravenous route for premature babies. These catheters allow administration of parenteral nutrition and medication and facilitate blood sampling. Besides these benefits, they also have significant potential complications like portal vein thrombosis, infection, vascular or hepatic injury, arrhythmia and sepsis. One of the rare but important complication is extravasation of the fluids due to misplacement of the catheter. The typical symptoms of this condition are sudden deterioration, hepatic enlargement, hematocrit drop, hypotension and abdominal distension. We herein present a premature newborn with unusual acute abdomen findings suggesting a surgical pathology after the extravasation of total parenteral nutrition into the abdomen. Sociedad Argentina de Pediatría.

  7. Ease of intravenous catheterisation in dogs and cats: a comparative study of two peripheral catheters.

    PubMed

    Chebroux, A; Leece, E A; Brearley, J C

    2015-04-01

    To evaluate animal comfort and ease of placement of a veterinary-specific intravenous catheter compared with a catheter manufactured for human use. Fifty-nine veterinary undergraduates were recruited to perform intravenous catheterisations with two brands of over-the-needle catheter [Smiths Medical Jelco® (human use) and Abbott Animal Health catheter® (veterinary use)] in 69 healthy cats (n = 28) and dogs (n = 41) requiring general anaesthesia. After a standardised pre-anaesthetic medication, each animal was randomly allocated to have one of the two brands of catheter placed. Each student was allowed a maximum of three attempts to achieve cephalic vein catheterisation. The student and a single experienced observer evaluated each attempt. Observations related to ease of placement and to the animal's reaction were recorded. Human use catheters were placed in 34 and veterinary use in 35 animals. There was no difference in weight, sex or sedation score between the two groups. The number of failed attempts was similar between the two groups. There was no difference between groups for the number of animals reacting to catheter insertion. The two types of catheters evaluated are equally suitable for intravenous catheterisation of sedated animals by veterinary undergraduate students. © 2015 British Small Animal Veterinary Association.

  8. A rare case of renal vein thrombosis due to urinary obstruction.

    PubMed

    Jana, Tanima; Orlander, Philip R; Molony, Donald A

    2015-08-01

    Renal vein thrombosis (RVT) is an uncommon condition in adults and may be caused by endothelial damage, stasis, or hypercoagulable states. RVT is commonly identified in patients with nephrotic syndrome or malignancy. We present the case of a 57-yearold man with no past medical history who presented with a 1-month history of abdominal pain, dysuria, and hematuria. Initial laboratory studies were consistent with acute kidney injury (AKI). Imaging revealed bladder distension, enlargement of the prostate, bilateral hydronephrosis, and left renal vein thrombosis extending into the inferior vena cava. His renal failure and presenting symptoms resolved with placement of a Foley catheter and ureteral stent. The patient was discharged on anticoagulation. Here, we report a rare case of RVT that appears to have occurred as a consequence of obstructive uropathy causing massive bladder distention resulting in compression of the renal vein.

  9. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  10. Short-term infection in cuffed versus noncuffed small bore central catheters: a randomized trial.

    PubMed

    Trerotola, Scott O; Patel, Aalpen A; Shlansky-Goldberg, Richard D; Solomon, Jeffrey A; Mondschein, Jeffrey I; Stavropoulos, S William; Soulen, Michael C; Itkin, Maxim; Chittams, Jesse

    2010-02-01

    To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

  11. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.

    PubMed

    Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T

    2009-12-01

    To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

  12. Vascular adaptations for heat conservation in the tail of Florida manatees (Trichechus manatus latirostris)

    PubMed Central

    Rommel, Sentiel A; Caplan, Heather

    2003-01-01

    Although Florida manatees (Trichechus manatus latirostris) have relatively low basal metabolic rates for aquatic mammals of their size, they maintain normal mammalian core temperatures. We describe vascular structures in the manatee tail that permit countercurrent heat exchange (CCHE) to conserve thermal energy. Approximately 1000 arteries juxtaposed to 2000 veins are found at the cranial end of the caudal vascular bundle (CVB); these numbers decrease caudally, but the 1 : 2 ratio of arteries to veins persists. Arterial walls are relatively thin when compared to those previously described in vascular countercurrent heat exchangers in cetaceans. It is assumed that CCHE in the CVB helps manatees to maintain core temperatures. Activity in warm water, however, mandates a mechanism that prevents elevated core temperatures. The tail could transfer heat to the environment if arterial blood delivered to the skin were warmer than the surrounding water; unfortunately, CCHE prevents this heat transfer. We describe deep caudal veins that provide a collateral venous return from the tail. This return, which is physically outside the CVB, reduces the venous volume within the bundle and allows arterial expansion and increased arterial supply to the skin, and thus helps prevent elevated core temperatures. PMID:12739612

  13. Vascular adaptations for heat conservation in the tail of Florida manatees (Trichechus manatus latirostris).

    PubMed

    Rommel, Sentiel A; Caplan, Heather

    2003-04-01

    Although Florida manatees (Trichechus manatus latirostris) have relatively low basal metabolic rates for aquatic mammals of their size, they maintain normal mammalian core temperatures. We describe vascular structures in the manatee tail that permit countercurrent heat exchange (CCHE) to conserve thermal energy. Approximately 1000 arteries juxtaposed to 2000 veins are found at the cranial end of the caudal vascular bundle (CVB); these numbers decrease caudally, but the 1:2 ratio of arteries to veins persists. Arterial walls are relatively thin when compared to those previously described in vascular countercurrent heat exchangers in cetaceans. It is assumed that CCHE in the CVB helps manatees to maintain core temperatures. Activity in warm water, however, mandates a mechanism that prevents elevated core temperatures. The tail could transfer heat to the environment if arterial blood delivered to the skin were warmer than the surrounding water; unfortunately, CCHE prevents this heat transfer. We describe deep caudal veins that provide a collateral venous return from the tail. This return, which is physically outside the CVB, reduces the venous volume within the bundle and allows arterial expansion and increased arterial supply to the skin, and thus helps prevent elevated core temperatures.

  14. Central Vein Dilatation Prior to Concomitant Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian

    2010-04-15

    Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less

  15. Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery

    PubMed Central

    Teragawa, Hiroki; Sueda, Takashi; Fujii, Yuichi; Takemoto, Hiroaki; Toyota, Yasushi; Nomura, Shuichi; Nakagawa, Keigo

    2013-01-01

    We report a successful endovascular technique using a snare with a suture for retrieving a migrated broken peripherally inserted central catheter (PICC) in a chemotherapy patient. A 62-year-old male received monthly chemotherapy through a central venous port implanted into his right subclavian area. The patient completed chemotherapy without complications 1 mo ago; however, he experienced pain in the right subclavian area during his last chemotherapy session. Computed tomography on that day showed migration of a broken PICC in his left pulmonary artery, for which the patient was admitted to our hospital. We attempted to retrieve the ectopic PICC through the right jugular vein using a gooseneck snare, but were unsuccessful because the catheter was lodged in the pulmonary artery wall. Therefore, a second attempt was made through the right femoral vein using a snare with triple loops, but we could not grasp the migrated PICC. Finally, a string was tied to the top of the snare, allowing us to curve the snare toward the pulmonary artery by pulling the string. Finally, the catheter body was grasped and retrieved. The endovascular suture technique is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters. PMID:24109502

  16. Percutaneous Catheterization of the Internal Jugular Vein for Hemodialysis

    PubMed Central

    Yeum, Chung Ho; Kim, Soo Wan; Nah, Myong Yun; Ma, Seong Kwon; Ko, Jung Hee; Kim, Nam Ho; Choi, Ki Chul

    2001-01-01

    Objectives The present study was aimed at evaluating the clinical experiences in the internal jugular venous catheterization for hemodialysis. Methods We retrospectively analyzed the data on internal jugular venous catheterization at Chonnam National University Hospital from May 2000 to Februrary 2001. Results There were 132 uremic patients with a total of 150 attempts of internal jugular cannulation. Overall success rate was 90.9% with average puncture trials of 2.3±2.1. 124 (82.7%) of the catheterization attempts were made on the right side and 26 (17.3%) were made on the left. The catheters were left in place from 2 to 87 days with an average of 19.5±15.3 days per catheter. The dialysis sessions per catheter were from 2 to 58 with an average of 11.3±6.8. The mean blood flow during hemodialysis immediately after catheterization was 213.4±42.2 ml/min. Thirty two (21.3%) patients had early complications. These included carotid artery puncture (11.3%), local bleeding (4.7%), local pain (3.3%), neck hematoma (0.7%) and malposition of the catheter (1.3%). Seventeen (11.3%) patients had late complications. These included fever or infection (11.3%), inadequate blood flow rate (3.3%) and inadvertent withdrawal (2.0%). There was no catheter-related mortality. Conclusions Our experiences revealed that the internal jugular vein catheterization is relatively safe and efficient for temporary vascular access for hemodialysis. PMID:11855153

  17. Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

    PubMed Central

    Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung

    2012-01-01

    Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269

  18. Infection and natural history of emergency department-placed central venous catheters.

    PubMed

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  19. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    PubMed

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  20. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    PubMed

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  1. In Vivo Imaging of Branched Chain Amino Acid Metabolism in Prostate Cancer

    DTIC Science & Technology

    2012-08-01

    system with heart rate and O2 saturation recorded using a pulse oximeter . Within a given scanning session, each mouse received one bolus injection... oxygen (~1.5 l/min), a tail vein catheter was inserted into each mouse, and the animal placed in a custom-build dual-tuned 13C/1H quadrature

  2. Risk factors for upper extremity venous thrombosis associated with peripherally inserted central venous catheters.

    PubMed

    Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David

    2012-01-01

    To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in

  3. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    PubMed

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  4. Pseudocyst in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage.

    PubMed

    Naitoh, Itaru; Ohara, Hirotaka; Okayama, Yasutaka; Nakazawa, Takahiro; Ando, Tomoaki; Hayashi, Kazuki; Okumura, Fumihiro; Kitajima, Yasuhiro; Ban, Tessin; Miyabe, Katsuyuki; Ueno, Koichiro; Joh, Takashi; Sano, Hitoshi

    2008-09-01

    We report a 50-year-old male with pseudocysts in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage. He had previously undergone ultrasonography-guided percutaneous cyst drainage for a pancreatic pseudocyst in our hospital. He was readmitted due to abdominal pain and fever. Computed tomography showed recurrence of a pseudocyst in the pancreatic tail measuring 5 cm in diameter. Since conservative treatment failed, endoscopic retrograde pancreatography was performed. There was communication between the pseudocyst and the main pancreatic duct, and pancreatic duct stenosis proximal to the pseudocyst. First, transpapillary pancreatic duct drainage was performed using a plastic stent, but the pseudocyst did not decrease in size and became infected. After removal of the stent, a pigtail type nasocystic catheter was placed in the pseudocyst via the pancreatic duct. The pseudocyst infection immediately disappeared, and the pseudocyst gradually decreased and disappeared. After removal of the nasocystic catheter, no recurrence was observed. As transpapillary drainage of pancreatic pseudocyst, cyst drainage and pancreatic duct drainage have been reported. In our patient with pseudocyst in the pancreatic tail, duct drainage was ineffective and the pseudocyst was infected, whereas cyst drainage was very effective. We considered that cyst drainage by a nasocystic catheter was the first-line therapy as the transpapillary drainage of the pancreatic pseudocyst.

  5. Pseudocyst in the Pancreatic Tail Associated with Chronic Pancreatitis Successfully Treated by Transpapillary Cyst Drainage

    PubMed Central

    Naitoh, Itaru; Ohara, Hirotaka; Okayama, Yasutaka; Nakazawa, Takahiro; Ando, Tomoaki; Hayashi, Kazuki; Okumura, Fumihiro; Kitajima, Yasuhiro; Ban, Tessin; Miyabe, Katsuyuki; Ueno, Koichiro; Joh, Takashi; Sano, Hitoshi

    2008-01-01

    We report a 50-year-old male with pseudocysts in the pancreatic tail associated with chronic pancreatitis successfully treated by transpapillary cyst drainage. He had previously undergone ultrasonography-guided percutaneous cyst drainage for a pancreatic pseudocyst in our hospital. He was readmitted due to abdominal pain and fever. Computed tomography showed recurrence of a pseudocyst in the pancreatic tail measuring 5 cm in diameter. Since conservative treatment failed, endoscopic retrograde pancreatography was performed. There was communication between the pseudocyst and the main pancreatic duct, and pancreatic duct stenosis proximal to the pseudocyst. First, transpapillary pancreatic duct drainage was performed using a plastic stent, but the pseudocyst did not decrease in size and became infected. After removal of the stent, a pigtail type nasocystic catheter was placed in the pseudocyst via the pancreatic duct. The pseudocyst infection immediately disappeared, and the pseudocyst gradually decreased and disappeared. After removal of the nasocystic catheter, no recurrence was observed. As transpapillary drainage of pancreatic pseudocyst, cyst drainage and pancreatic duct drainage have been reported. In our patient with pseudocyst in the pancreatic tail, duct drainage was ineffective and the pseudocyst was infected, whereas cyst drainage was very effective. We considered that cyst drainage by a nasocystic catheter was the first-line therapy as the transpapillary drainage of the pancreatic pseudocyst. PMID:21897788

  6. A systematic review of ultrasound-accelerated catheter-directed thrombolysis in the treatment of deep vein thrombosis.

    PubMed

    Shi, Yadong; Shi, Wanyin; Chen, Liang; Gu, Jianping

    2018-04-01

    To review the clinical evidence for ultrasound-accelerated catheter-directed thrombolysis (UACDT) using the EKOS system in the treatment of deep vein thrombosis (DVT) in terms of case selection, procedural outcomes, clinical outcomes and safety outcomes. A systematic literature search strategy was used to identify the use of the EKOS system in the treatment of DVT using the following electronic databases: MEDLINE, EMBASE, the Cochrane databases and the Web of Science. The references in the relevant literature were also screened. Our literature search identified a total of 16 unique clinical studies. Twelve of the sixteen studies were retrospective case series studies. To date, only one randomised controlled trial (RCT) is available. Overall, UACDT using the EKOS system was performed 548 times in 512 patients. Among all cases, 77-100% achieved substantial lysis (> 50%) based on the different definitions of the individual studies. This treatment modality appears to be safe, as there were no reported procedure-related pulmonary embolisms (PE) and only one procedure-related death was reported. Bleeding events were reported in 14 of the 16 studies, and 3.9% (20/512) of the cases of bleeding were considered major. During the follow-up, post-thrombotic syndrome was observed in 17.1% (20/117) of cases. UACDT using the EKOS system is an effective, safe and promising treatment modality for DVT, but the existing clinical evidence is inadequate to make UACDT using the EKOS system the first-line choice for DVT. Additional prospective large-sample RCTs with long-term follow-ups are warranted to define the role of UACDT using the EKOS system in the treatment of DVT.

  7. Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation.

    PubMed

    Miyazaki, Shinsuke; Shah, Ashok J; Xhaët, Olivier; Derval, Nicolas; Matsuo, Seiichiro; Wright, Matthew; Nault, Isabelle; Forclaz, Andrei; Jadidi, Amir S; Knecht, Sébastien; Rivard, Lena; Liu, Xingpeng; Linton, Nick; Sacher, Frédéric; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel

    2010-12-01

    The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 ± 27 versus 43 ± 16 minutes; P = 0.0019) than in the manual group (246 ± 50 versus 153 ± 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 ± 24 versus 40 ± 14 minutes; P = 0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P = 0.961). Cardiac tamponade occurred in 1 patient in the manual group. In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage.

  8. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

    PubMed

    Maurer, Tilman; Rottner, Laura; Makimoto, Hisaki; Reissmann, Bruno; Heeger, Christian-H; Lemes, Christine; Fink, Thomas; Riedl, Johannes; Santoro, Francesco; Wohlmuth, Peter; Volkmer, Marius; Mathew, Shibu; Metzner, Andreas; Ouyang, Feifan; Kuck, Karl-Heinz; Sohns, Christian

    2018-05-08

    This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter ("Thermocool SmartTouch SurroundFlow"; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device. A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation ("Thermocool SmartTouch", 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10-39 g and a force time integral (FTI) of > 400 g s was targeted. Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan-Meier estimate 12-month arrhythmia-free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18). PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in

  9. The air-bubble method of locking central-vein catheters with acidified, concentrated sodium chloride as a bactericidal agent: in vitro studies.

    PubMed

    Moore, Harold L; Twardowski, Zbylut J

    2003-10-01

    Soft, cuffed indwelling catheters are used for hemodialysis access and intravenous infusions. The majority of these catheters are removed as a result of infection caused by contamination of the catheter hub during the connection/disconnection procedures. To prevent clot formation in the lumen, these catheters are routinely "locked" with heparin or some other anticoagulant. None of the anticoagulants commonly used as locking solutions demonstrates any significant bactericidal properties. The primary goal of this study was the development of a catheter locking method that retains anticoagulant properties at the catheter tip and bactericidal properties at the catheter hub. The second goal was to find a solution that possesses excellent bactericidal properties but is not detrimental in the event of injection into the patient's blood stream. The bactericidal properties of acidified, concentrated saline (ACS) were compared to concentrated trisodium citrate and to commonly used bactericidal agents such as povidone iodine, sodium hypochlorite, and chlorhexidine. In preliminary studies, the rate of diffusion of solutes was measured in glass tubes. In another set of experiments, the mixing of two solutions (anticoagulant and bactericide) separated by an air bubble ("air-bubble method") was observed in stationary and moving systems. The final series of studies compared the bactericidal properties of ACS to other bactericidal solutions mentioned above. The solutions diffused swiftly in the glass tubes, and by the third day, both solutions were mixed. The air-bubble method prevented mixing in both stationary and moving systems. The bactericidal properties of ACS were superior to all other tested solutions. The proposed method of catheter locking with anticoagulant at the catheter tip and ACS at the catheter hub separated by an air bubble is a promising technique and clinical studies are warranted.

  10. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong

    PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less

  11. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein.

    PubMed

    Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil

    2017-03-01

    The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

  12. Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.

    PubMed

    Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji

    2018-06-01

    To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.

  13. Pulmonary vein anatomy predicts freedom from atrial fibrillation using remote magnetic navigation for circumferential pulmonary vein ablation.

    PubMed

    Sohns, Christian; Sohns, Jan M; Bergau, Leonard; Sossalla, Samuel; Vollmann, Dirk; Lüthje, Lars; Staab, Wieland; Dorenkamp, Marc; Harrison, James L; O'Neill, Mark D; Lotz, Joachim; Zabel, Markus

    2013-08-01

    Multidetector computed tomography (MDCT) is frequently used to guide circumferential pulmonary vein ablation (PVA) for treatment of atrial fibrillation (AF) as it offers accurate visualization of the left atrial (LA) and pulmonary vein (PV) anatomy. This study aimed to identify if PV anatomy is associated with outcomes following PVA using remote magnetic navigation (RMN). We analysed data from 138 consecutive patients and 146 ablation procedures referred for PVA due to drug-refractory symptomatic AF (age 63 ± 11 years; 57% men; 69% paroxysmal AF). The RMN using the stereotaxis system and open-irrigated 3.5 mm ablation catheters was used in all procedures. Prior to PVA, all patients underwent electrocardiogram-gated 64-MDCT for assessment of LA dimensions, PV anatomy, and electro-anatomical image integration during the procedure. Regular PV anatomy was found in 68%, a common left PV ostium was detected in 26%, and variant anatomy of the right PVs was detected in 6%. After a mean follow-up of 337 ± 102 days, 63% of the patients maintained sinus rhythm after the initial ablation, and 83% when including repeat PVA. Although acutely successful PV isolation did not differ between anatomical subgroups (regular 3.5 ± 0.8 vs. variant 3.2 ± 1.3; P = 0.31), AF recurrence was significantly higher in patients with non-regular PV anatomy (P = 0.04, hazard ratio 1.72). Pulmonary vein anatomy did not influence complication rates. Pulmonary vein anatomy assessed by MDCT is a good predictor of AF recurrence after PVA using RMN.

  14. Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakamoto, Noriaki, E-mail: nosakamoto@hotmail.co.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Takeuchi, Yoshito, E-mail: yostakeu@ncc.go.jp

    2010-10-15

    The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurredmore » in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.« less

  15. Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.

    PubMed

    Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai

    2014-01-01

    Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.

  16. Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation-the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale.

    PubMed

    Andrade, Jason G; Deyell, Marc W; Badra, Mariano; Champagne, Jean; Dubuc, Marc; Leong-Sit, Peter; Macle, Laurent; Novak, Paul; Roux, Jean-Francois; Sapp, John; Tang, Anthony; Verma, Atul; Wells, George A; Khairy, Paul

    2017-10-05

    Pulmonary vein isolation (PVI) is an effective therapy for paroxysmal atrial fibrillation (AF), but it has limitations. The two most significant recent advances have centred on the integration of real-time quantitative assessment of catheter contact force into focal radio frequency (RF) ablation catheters and the development of dedicated ablation tools capable of achieving PVI with a single ablation lesion (Arctic Front cryoballoon, Medtronic, Minneapolis, MN, USA). Although each of these holds promise for improving the clinical success of catheter ablation of AF, there has not been a rigorous comparison of these advanced ablation technologies. Moreover, the optimal duration of cryoablation (freezing time) has not been determined. Patients undergoing an initial PVI procedure for paroxysmal AF will be recruited. Patients will be randomised 1:1:1 between contact-force irrigated RF ablation, short duration cryoballoon ablation (2 min applications) and standard duration cryoballoon ablation (4 min applications). The primary outcome is time to first documented AF recurrence on implantable loop recorder. With a sample size of 111 per group and a two-sided 0.025 significance level (to account for the two main comparisons), the study will have 80% power (using a log-rank test) to detect a difference of 20% between contact force RF catheter ablation and either of the two cryoballoon ablation groups. Factoring in a 4% loss to follow-up, 116 patients per group should be randomised and followed for a year (total study population of 348). The study was approved by the University of British Columbia Office of Research (Services) Ethics Clinical Research Ethics Board. Results of the study will be submitted for publication in a peer-reviewed journal. NCT01913522; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Urinary catheters

    MedlinePlus

    ... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...

  18. New technology applications: thrombolysis of acute deep vein thrombosis.

    PubMed

    Marchigiano, Gail; Riendeau, Debra; Jo Morse, Carol

    2006-01-01

    Treatment of deep vein thrombosis traditionally has focused on preventing the potentially life-threatening complication of pulmonary embolism rather than on removing or reducing the thrombus. Although treatment with anticoagulants may prevent thrombus propagation, the body's intrinsic thrombolytic system is left to attempt clot dissolution. Because this natural process is generally ineffective in its ability to fully recanalize a proximal vein, the risks of recurrent thrombosis as well as the disabling complication of postthrombotic syndrome increase. Moreover, the long-term consequences of postthrombotic syndrome include pain, disability, and, for many, a significant decrease in the quality of life. Recent technology using high-frequency, low-power ultrasound, or mechanical thrombectomy with catheter-directed delivery of a thrombolytic drug directly into the clot is available and showing promise. Nurses are caring for patients who receive endovascular interventions with lytic infusions. The nursing challenge is to provide safe and effective patient care.

  19. MEMS-Based Flexible Force Sensor for Tri-Axial Catheter Contact Force Measurement

    PubMed Central

    Sheng, Jun; Desai, Jaydev P.

    2016-01-01

    Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter contact force measurement during RF ablation can reduce the rate of AFib recurrence, since it helps to determine effective contact of the catheter with the tissue, thereby resulting in effective power delivery for ablation. This paper presents the development of a three-dimensional (3D) force sensor to provide the real-time measurement of tri-axial catheter contact force. The 3D force sensor consists of a plastic cubic bead and five flexible force sensors. Each flexible force sensor was made of a PEDOT:PSS strain gauge and a PDMS bump on a flexible PDMS substrate. Calibration results show that the fabricated sensor has a linear response in the force range required for RF ablation. To evaluate its working performance, the fabricated sensor was pressed against gelatin tissue by a micromanipulator and also integrated on a catheter tip to test it within deionized water flow. Both experiments simulated the ventricular environment and proved the validity of applying the 3D force sensor in RF ablation. PMID:28190945

  20. Outcomes of catheter-directed treatment of lower extremity deep vein thrombosis of patients presenting to a tertiary care hospital.

    PubMed

    Sundar, Gaurav; Keshava, Shyamkumar N; Moses, Vinu; Chiramel, George K; Ahmed, Munawwar; Mammen, Suraj; Aggarwal, Sunil; Stephen, Edwin

    2016-01-01

    Lower extremity deep vein thrombosis (DVT) is a common illness with an annual incidence of 1 per 1000 adults. The major long-term complication of DVT is post-thrombotic syndrome (PTS) which occurs in up to 60% of patients within 2 years of an episode of DVT. We aim to evaluate the outcomes of catheter-directed treatment (CDT) for symptomatic acute or subacute lower extremity DVT. A retrospective 12-year study was conducted on the outcomes of CDT on 54 consecutive patients who presented with acute or subacute lower extremity DVT to our hospital. Descriptive summary statistics and the Chi-square test were used to measure the outcomes of CDT. Grade 3 thrombolysis was achieved in 25 (46.3%) patients, grade 2 thrombolysis in 25 (46.3%) patients, and grade 1 thrombolysis in 4 (7.4%) patients. Significant recanalization (grade 2 or 3 thrombolysis) was possible in 50 (92.6%) patients. There was no statistically significant difference in the percentage of significant recanalization that could be achieved between patients who underwent CDT before and after 10 days. There was no significant difference between the thrombolysis achieved between urokinase and r-tPA. PTS was seen in 33% of the patients. Major complications were seen in 5.5% of the patients. CDT is a safe and effective therapeutic technique in patients with acute and subacute lower extremity DVT, if appropriate patient selection is made.

  1. Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.

    PubMed

    Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G

    2013-04-01

    This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.

  2. Hydrophilic Catheters

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the

  3. Risk of Venous Thromboembolism Following Peripherally Inserted Central Catheter Exchange: An Analysis of 23,000 Hospitalized Patients.

    PubMed

    Chopra, Vineet; Kaatz, Scott; Grant, Paul; Swaminathan, Lakshmi; Boldenow, Tanya; Conlon, Anna; Bernstein, Steven J; Flanders, Scott A

    2018-02-01

    Catheter exchange over a guidewire is frequently performed for malfunctioning peripherally inserted central catheters (PICCs). Whether such exchanges are associated with venous thromboembolism is not known. We performed a retrospective cohort study to assess the association between PICC exchange and risk of thromboembolism. Adult hospitalized patients that received a PICC during clinical care at one of 51 hospitals participating in the Michigan Hospital Medicine Safety consortium were included. The primary outcome was hazard of symptomatic venous thromboembolism (radiographically confirmed upper-extremity deep vein thrombosis and pulmonary embolism) in those that underwent PICC exchange vs those that did not. Of 23,010 patients that underwent PICC insertion in the study, 589 patients (2.6%) experienced a PICC exchange. Almost half of all exchanges were performed for catheter dislodgement or occlusion. A total of 480 patients (2.1%) experienced PICC-associated deep vein thrombosis. The incidence of deep vein thrombosis was greater in those that underwent PICC exchange vs those that did not (3.6% vs 2.0%, P < .001). Median time to thrombosis was shorter among those that underwent exchange vs those that did not (5 vs 11 days, P = .02). Following adjustment, PICC exchange was independently associated with twofold greater risk of thrombosis (hazard ratio [HR] 1.98; 95% confidence interval [CI], 1.37-2.85) vs no exchange. The effect size of PICC exchange on thrombosis was second in magnitude to device lumens (HR 2.06; 95% CI, 1.59-2.66 and HR 2.31; 95% CI, 1.6-3.33 for double- and triple-lumen devices, respectively). Guidewire exchange of PICCs may be associated with increased risk of thrombosis. As some exchanges may be preventable, consideration of risks and benefits of exchanges in clinical practice is needed. Published by Elsevier Inc.

  4. Contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

    PubMed

    Krause, Ulrich; Backhoff, David; Klehs, Sophia; Schneider, Heike E; Paul, Thomas

    2016-08-01

    Monitoring of catheter contact force during catheter ablation of atrial fibrillation has been shown to increase efficacy and safety. However, almost no data exists on the use of this technology in catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease. The aim of the present study was to evaluate the impact of contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in those patients. Catheter ablation of intraatrial reentrant tachycardia using monitoring of catheter contact force was performed in 28 patients with congenital heart disease (CHD). Thirty-two patients matched according to gender, age, and body weight with congenital heart disease undergoing catheter ablation without contact force monitoring served as control group. Parameters reflecting acute procedural success, long-term efficacy, and safety were compared. Acute procedural success was statistically not different in both groups (contact force 93 % vs. control 84 %, p = 0.3). Likewise the recurrence rate 1 year after ablation as shown by Kaplan-Meier analysis did not differ (contact force 28 % vs. control 37 %, p = 0.63). Major complications were restricted to groin vessel injuries and occurred in 3 out of 60 patients (contact force n = 1; control n = 2). Complications related to excessive catheter contact force were not observed. The present study did not show superiority of catheter contact force monitoring during ablation of intraatrial reentrant tachycardia in patients with CHD in terms of efficacy and safety. Higher contact force compared to pulmonary vein isolation might therefore be required to increase the efficacy of catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

  5. [Absence of chemical interaction between short catheters (ETFE) and three major antibiotics. Study model].

    PubMed

    Minosio, J P; Bourget, P; Clapeau, G; Rieutord, A; Hamon, M

    1994-01-01

    Recourse to sounding with vein catheters is more and more frequent in hospital environments. At the same time, a perceptible increase in incidents and accidents linked to this constantly growing practice is noted. The multiplication of new biomaterials used in the composition of catheters leads to taking into account the criteria of innocuousness and physiochemical inertia as discriminant elements in the choice of biomaterials. A study in vitro has been undertaken of the interaction between short catheters made of ethylenetetrafluoroethylen (ETFE) and antibiotic solutions widely used in hospital environments. The confrontation concerned solutions of vancomycine (Vancocin), ciprofloxacine (Ciflox) and the amoxicillin-clavulanic acid (Augmentin) association. A device has been fitted up and operative conditions have been set in order that the flushing out of the catheters by the solutions be in quality and quantity, as near as possible to actual conditions of use. The interaction marked chosen being a possible release of fluorides ions by the polymer, the determination of this anion has been made by liquid-gas chromatography paired with a flame ionization detection. We show the inertia of ETFE catheters with respect to the solutions examined. Taking into account the initially defined objectives, the conclusion of the work is important and constitutes a considerable factor of security for the catheters user whether he be buyer or practitioner. The model of study making up this approach could very be applied to other categories of materials and therapeutics.

  6. THE MECHANISM OF LESION FORMATION BY FOCUSED ULTRASOUND ABLATION CATHETER FOR TREATMENT OF ATRIAL FIBRILLATION

    PubMed Central

    Sinelnikov, Y.D.; Fjield, T.; Sapozhnikov, O.A.

    2009-01-01

    The application of therapeutic ultrasound for the treatment of atrial fibrillation (AF) is investigated. The results of theoretical and experimental investigation of ultrasound ablation catheter are presented. The major components of the catheter are the high power cylindrical piezoelectric element and parabolic balloon reflector. Thermal elevation in the ostia of pulmonary veins is achieved by focusing the ultrasound beam in shape of a torus that transverses the myocardial tissue. High intensity ultrasound heating in the focal zone results in a lesion surrounding the pulmonary veins that creates an electrical conduction blocks and relief from AF symptoms. The success of the ablation procedure largely depends on the correct choice of reflector geometry and ultrasonic power. We present a theoretical model of the catheter’s acoustic field and bioheat transfer modeling of cardiac lesions. The application of an empirically derived relation between lesion formation and acoustic power is shown to correlate with the experimental data. Developed control methods combine the knowledge of theoretical acoustics and the thermal lesion formation simulations with experiment and thereby establish rigorous dosimetry that contributes to a safe and effective ultrasound ablation procedure. PMID:20161431

  7. Pulmonary vein stenosis in patients with Smith-Lemli-Opitz syndrome.

    PubMed

    Prosnitz, Aaron R; Leopold, Jane; Irons, Mira; Jenkins, Kathy; Roberts, Amy E

    2017-07-01

    To describe a group of children with co-incident pulmonary vein stenosis and Smith-Lemli-Opitz syndrome and to generate hypotheses as to the shared pathogenesis of these disorders. Retrospective case series. Five subjects in a pulmonary vein stenosis cohort of 170 subjects were diagnosed with Smith-Lemli-Opitz syndrome soon after birth. All five cases were diagnosed with Smith-Lemli-Opitz syndrome within 6 weeks of life, with no family history of either disorder. All cases had pathologically elevated 7-dehydrocholesterol levels and two of the five cases had previously reported pathogenic 7-dehydrocholesterol reductase mutations. Smith-Lemli-Opitz syndrome severity scores ranged from mild to classical (2-7). Gestational age at birth ranged from 35 to 39 weeks. Four of the cases were male by karyotype. Pulmonary vein stenosis was diagnosed in all cases within 2 months of life, earlier than most published cohorts. All cases progressed to bilateral disease and three cases developed atresia of at least one vein. Despite catheter and surgical interventions, all subjects' pulmonary vein stenosis rapidly recurred and progressed. Three of the subjects died, at 2 months, 3 months, and 11 months. Survival at 16 months after diagnosis was 43%. Patients with pulmonary vein stenosis who have a suggestive syndromic presentation should be screened for Smith-Lemli-Opitz syndrome with easily obtainable serum sterol tests. Echocardiograms should be obtained in all newly diagnosed patients with Smith-Lemli-Opitz syndrome, with a low threshold for repeating the study if new respiratory symptoms of uncertain etiology arise. Further studies into the pathophysiology of pulmonary vein stenosis should consider the role of cholesterol-based signaling pathways in the promotion of intimal proliferation. © 2017 Wiley Periodicals, Inc.

  8. An Intelligent Catheter System Robotic Controlled Catheter System

    PubMed Central

    Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.

    2001-01-01

    Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387

  9. The mid-sternal length, a practical anatomical landmark for optimal positioning of long-term central venous catheters

    PubMed Central

    Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah

    2013-01-01

    Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941

  10. Peroperative electrocardiographic control of catheter tip position during implantation of femoral venous ports.

    PubMed

    Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis

    2015-01-01

    Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

  11. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    PubMed

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (< 1 mm) for a length of 40 mm, or the anterior half of the SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular

  12. Comparison of heparinized saline and 0.9% sodium chloride for maintaining peripheral intravenous catheter patency in dogs.

    PubMed

    Ueda, Yu; Odunayo, Adesola; Mann, F A

    2013-01-01

    To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.

  13. Management of complications related to central venous catheters in cancer patients: an update.

    PubMed

    Linnemann, Birgit

    2014-04-01

    Central venous catheters (CVCs) are important for the treatment of patients with cancer, especially in the perioperative and palliative care settings. These devices not only allow for the administration of chemotherapy, parenteral nutrition, and other intravenous therapies, but they may also improve the patients' quality of life by reducing the need for repeated peripheral venipunctures. Thrombotic and infectious complications are common, especially in the long-term use of CVCs. There are different types of thrombotic complications associated with CVCs, that is, a thrombotic occlusion of the catheter, a mural thrombus at the catheter tip and classical deep vein thrombosis, which occurs most frequently in the upper extremity where the majority of long-term catheters are inserted. Infections are common complications associated with CVCs. Patients with cancer who receive intensive chemotherapy and those patients who undergo hematopoietic stem cell transplantation have a markedly increased risk for insertion site and bloodstream infections. In this review, the epidemiology and risk factors that predispose patients to CVC-related thrombosis and infection are discussed. The diagnostic and therapeutic options according to the published data and the current guidelines are summarized and data for establishing primary and secondary preventative strategies are provided. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. A deflectable guiding catheter for real-time MRI-guided interventions.

    PubMed

    Bell, Jamie A; Saikus, Christina E; Ratnayaka, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z; Colyer, Jessica H; Lederman, Robert J; Kocaturk, Ozgur

    2012-04-01

    To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. Copyright © 2011 Wiley Periodicals, Inc.

  15. A deflectable guiding catheter for real-time MRI-guided interventions

    PubMed Central

    Bell, Jamie A.; Saikus, Christina E.; Ratnakaya, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z.; Colyer, Jessica H.; Lederman, Robert J.; Kocaturk, Ozgur

    2011-01-01

    Purpose To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. Materials and Methods The catheter shaft incorporated Kevlar braiding. 180° deflection was attained with a 5 cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively-coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Results Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Conclusion Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057” lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. PMID:22128071

  16. ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, R. S.; Wiens, R. C.; Vaniman, D. T.

    The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. Furthermore, the drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, whilemore » the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This then allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. But, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.« less

  17. ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

    DOE PAGES

    Jackson, R. S.; Wiens, R. C.; Vaniman, D. T.; ...

    2016-05-13

    The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. Furthermore, the drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, whilemore » the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This then allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. But, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.« less

  18. Impact of Catheter Ablation for Paroxysmal Atrial Fibrillation in Patients With Sick Sinus Syndrome - Important Role of Non-Pulmonary Vein Foci.

    PubMed

    Hayashi, Kentaro; Fukunaga, Masato; Yamaji, Kyohei; An, Yoshimori; Nagashima, Michio; Hiroshima, Kenichi; Ohe, Masatsugu; Makihara, Yu; Yamashita, Kennosuke; Ando, Kenji; Iwabuchi, Masashi; Goya, Masahiko

    2016-01-01

    The clinical efficacy of catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) in patients with sick sinus syndrome (SSS) and the mechanism and predictors of recurrence are not yet completely elucidated. Of 963 consecutive patients who underwent PAF ablation during the study period, a total of 108 patients with SSS (SSS group) and 108 matched controls without SSS (non-SSS group) were followed up. During the follow-up period (mean, 32.8±17.5 months), the SSS group had significantly higher AF recurrence rate since the last procedure than the non-SSS group (26.9% vs. 12.0%; P=0.02). The SSS group had significantly higher prevalence of non-pulmonary vein (non-PV) foci than the non-SSS group (25.9% vs. 13.9%; P=0.027). On multivariate analysis congestive heart failure (HR, 13.7; 95% CI: 1.57-119; P=0.02) and non-PV foci (HR, 5.75; 95% CI: 1.69-19.6; P=0.005) were independent predictors of recurrence following CA in the SSS group. In the SSS group, 88 patients had bradycardia-tachycardia syndrome without prior permanent pacemaker implantation. Of these, 6 required pacemaker implantation because of AF and sinus pause recurrence. Patients with SSS are at higher risk of AF recurrence after CA. Non-PV foci are associated with AF recurrence following PAF with SSS.

  19. Comparison of resource utilization of pulmonary vein isolation: cryoablation versus RF ablation with three-dimensional mapping in the Value PVI Study.

    PubMed

    DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Lim, Hae W; Plummer, Lisa; Baker, James; Kowalski, Marcin; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter

    2014-06-01

    Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon

  20. Efficacy and safety of ultrasound-guided placement of central venous port systems via the right internal jugular vein in elderly oncologic patients: our single-center experience and protocol.

    PubMed

    Canfora, Alfonso; Mauriello, Claudio; Ferronetti, Antonio; Marte, Gianpaolo; Di Maio, Vittorio; Ciorra, Guido; Esposito, Maria Grazia; Giuliano, Maria Elena; Fregola, Giovanni; Barra, Luigi; Cuzzovaglia, Salvatore; Bottino, Vincenzo; Maida, Pietro

    2017-02-01

    Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.

  1. Risk factors for central venous catheter thrombotic complications in children and adolescents with cancer.

    PubMed

    Revel-Vilk, S; Yacobovich, J; Tamary, H; Goldstein, G; Nemet, S; Weintraub, M; Paltiel, O; Kenet, G

    2010-09-01

    The use of central venous catheters (CVCs) has greatly improved the quality of care in children with cancer, yet these catheters may cause serious infectious and thrombotic complications. The aim of this prospective registry study was to assess the host and CVC-related risk factors for CVC-created thrombotic complications. Patients undergoing CVC insertion for chemotherapy were followed prospectively for CVC complications. At the time of enrollment, demographic, clinical, and CVC-related data, and family history of thrombosis were collected. Survival and Cox regression analyses were performed. A total of 423 CVCs were inserted into 262 patients for a total of 76,540 catheter days. The incidence of CVC-related deep-vein thrombosis (DVT) was 0.13 per 1000 catheter-days (95% confidence interval [CI], 0.06-0.24). Insertion of peripherally inserted central catheters (PICCs) and insertion in an angiography suite significantly increased the risk of symptomatic CVC-related DVT. The incidence of CVC occlusion was 1.35 per 1000 catheter-days (95% CI, 1.1-1.63). Positive family history of thrombosis significantly increased the risk of CVC occlusion (hazard ratio [HR], 2.16; 95% CI, 1.2-3.8). The CVC-related risk factors were insertion of Hickman catheters, insertion in angiography suite, and proximal-tip location. Patients developing at least 1 episode of both CVC occlusion and infection had an increased risk for developing symptomatic CVC-related DVT (HR, 4.15; 95% CI, 1.2-14.4). Both patient-related and CVC-related factors are associated with higher risk of symptomatic thrombotic complications. These risk factors could be used in the clinical setting and in developing future studies for CVC thromboprophylaxis.

  2. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.

    PubMed

    Brass, Patrick; Hellmich, Martin; Kolodziej, Laurentius; Schick, Guido; Smith, Andrew F

    2015-01-09

    Central venous catheters (CVCs) can help with diagnosis and treatment of the critically ill. The catheter may be placed in a large vein in the neck (internal jugular vein), upper chest (subclavian vein) or groin (femoral vein). Whilst this is beneficial overall, inserting the catheter risks arterial puncture and other complications and should be performed with as few attempts as possible. Traditionally, anatomical 'landmarks' on the body surface were used to find the correct place in which to insert catheters, but ultrasound imaging is now available. A Doppler mode is sometimes used to supplement plain 'two-dimensional' ultrasound. The primary objective of this review was to evaluate the effectiveness and safety of two-dimensional (imaging ultrasound (US) or ultrasound Doppler (USD)) guided puncture techniques for insertion of central venous catheters via the internal jugular vein in adults and children. We assessed whether there was a difference in complication rates between traditional landmark-guided and any ultrasound-guided central vein puncture.Our secondary objectives were to assess whether the effect differs between US and USD; whether the effect differs between ultrasound used throughout the puncture ('direct') and ultrasound used only to identify and mark the vein before the start of the puncture procedure (indirect'); and whether the effect differs between different groups of patients or between different levels of experience among those inserting the catheters. We searched the Central Register of Controlled Trials (CENTRAL) (2013, Issue 1), MEDLINE (1966 to 15 January 2013), EMBASE (1966 to 15 January 2013), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to 15 January 2013 ), reference lists of articles, 'grey literature' and dissertations. An additional handsearch focused on intensive care and anaesthesia journals and abstracts and proceedings of scientific meetings. We attempted to identify unpublished or ongoing studies

  3. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    PubMed

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  4. SU-E-J-65: Motion Difference Between the Pancreas and Nearby Veins for Pancreas Motion Monitoring Using Ultrasound During Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omari, E; Erickson, B; Li, X

    2015-06-15

    Purpose: As it is generally difficult to outline the pancreas on an ultrasound b-mode image, visualized structures such as the portal or the splenic veins are assumed to have the same motion as the pancreas. These structures can be used as a surrogate for monitoring pancreas motion during radiation therapy (RT) delivery using ultrasound. To verify this assumption, we studied the motion difference between the head of the pancreas, the portal vein, the tail of the pancreas, and splenic vein. Methods: 4DCT data acquired during RT simulation were analyzed for a total of 5 randomly selected patients with pancreatic cancer.more » The data was sorted into 10 respiratory phases from 0% to 90% (0%: end of the inspiration, 50%: end of expiration) . The head of the pancreas (HP), tail of the pancreas (TP), portal vein (PV), and splenic vein (SV) were contoured on all 10 phases. The volume change and motion were measured in the left-right (LR), anterior-superior (AP), and superior-inferior (SI) directions. Results: The volume change for all patients/phases were: 1.2 ± 3% for HP, 0.78 ± 1.6% for PV, 2.5 ± 2.9% for TP, and 0.53 ± 2.1% for SV. Motion for each structure was estimated from the centroid displacements due to the uniformity of the structures and the small volume change. The measured motion between HP and PV was: LR: 0.1 ± 0.17 mm, AP: 0.04 ± 0.1 mm, SI: 0.17 ± 0.16 mm and between TP and the PV was: LR: 0.05 ± 0.3 mm, AP: 0.1 ± 0.4 mm, SI: 0.01 ± 0.022 mm. Conclusion: There are small motion differences between the portal vein and the head of the pancreas, and the splenic vein and the tail of the pancreas. This suggests the feasibility of utilizing these features for monitoring the pancreas motion during radiation therapy.« less

  5. A NEW PRINCIPLE FOR ELECTROMAGNETIC CATHETER FLOW METERS*

    PubMed Central

    Kolin, Alexander

    1969-01-01

    An electromagnetic catheter flow meter is described in which the magnetic field is generated by two parallel bundles of wire carrying equal currents in opposite directions. The electrodes are fixed centrally to the insulated wire bundles that generate the magnetic field. The flow sensor is flexible, resembling a split catheter. The flow transducer is designed to constrict as it is introduced through a branch artery and to expand in the main artery over the span of its diameter. The principle is suitable for branch flow measurement as well as for measurement of flow in a major artery or vein by the same transducer. A special method of guiding the electrode wires results in a zero base line at zero flow for the entire range of diameters accommodating the field generating coil. The electrodes could be used in this configuration with a magnetic field generated by coils external to the patient for blood flow measurements with a catheter of reduced gauge. The transducer can be made smaller in circumference than those employed in other electromagnetic flow measuring catheter devices. This feature is of special value for envisaged clinical uses (percutaneous introduction) to minimize surgical intervention. The velocity sensitivity of the flow transducer is a logarithmic function of the tube diameter. The flow throughout the entire tube cross section contributes to the flow signal. It is sufficient to calibrate the transducer by one measurement in a dielectric conduit of less than maximum diameter. The sensitivity at other diameters follows from a logarithmic plot. The diameter of the blood vessel is outlined by the transducer in radiograms, thus obviating the need for radiopaque materials. The principle was demonstrated by measurements in vitro. Experiments in vivo, derivation of equations, and construction details will be published elsewhere. Images PMID:5257127

  6. Isolated Disruption of the Right Coronary Artery Following a Steam Pop during Cavotricuspid Linear Ablation with a Contact Force Catheter.

    PubMed

    Brunelli, Michele; Frommhold, Markus; Back, Dieter; Mierzwa, Marco; Lauer, Bernard; Geller, J Christoph

    2016-07-01

    A 70-year-old woman with persistent atrial fibrillation underwent pulmonary vein isolation and linear ablation with a contact sensor catheter. During cavotricuspid isthmus ablation, a steam pop resulted in cardiac tamponade, and the patient developed severe hypotension despite successful pericardial puncture and minimal residual pericardial effusion. Right coronary artery angiography revealed extravasal contrast medium accumulation posterior of the Crux Cordis. Emergent cardiac surgery confirmed isolated disruption of the artery in the absence of additional heart perforation. Although contact sensor catheters may reduce complications, steam pops can still occur and result in dramatic complications. © 2016 Wiley Periodicals, Inc.

  7. Duplex sonography for detection of deep vein thrombosis of upper extremities: a 13-year experience.

    PubMed

    Chung, Amy S Y; Luk, W H; Lo, Adrian X N; Lo, C F

    2015-04-01

    To determine the prevalence and characteristics of sonographically evident upper-extremity deep vein thrombosis in symptomatic Chinese patients and identify its associated risk factors. Regional hospital, Hong Kong. Data on patients undergoing upper-extremity venous sonography examinations during a 13-year period from November 1999 to October 2012 were retrieved. Variables including age, sex, history of smoking, history of lower-extremity deep vein thrombosis, major surgery within 30 days, immobilisation within 30 days, cancer (history of malignancy), associated central venous or indwelling catheter, hypertension, diabetes mellitus, sepsis within 30 days, and stroke within 30 days were tested using binary logistic regression to understand the risk factors for upper-extremity deep vein thrombosis. The presence of upper-extremity deep vein thrombosis identified. Overall, 213 patients with upper-extremity sonography were identified. Of these patients, 29 (13.6%) had upper-extremity deep vein thrombosis. The proportion of upper-extremity deep vein thrombosis using initial ultrasound was 0.26% of all deep vein thrombosis ultrasound requests. Upper limb swelling was the most common presentation seen in a total of 206 (96.7%) patients. Smoking (37.9%), history of cancer (65.5%), and hypertension (27.6%) were the more prevalent conditions among patients in the upper-extremity deep vein thrombosis-positive group. No statistically significant predictor of upper-extremity deep vein thrombosis was noted if all variables were included. After backward stepwise logistic regression, the final model was left with only age (P=0.119), female gender (P=0.114), and history of malignancy (P=0.024) as independent variables. History of malignancy remained predictive of upper-extremity deep vein thrombosis. Upper-extremity deep vein thrombosis is uncommon among symptomatic Chinese population. The most common sign is swelling and the major risk factor for upper-extremity deep vein

  8. Comparative evaluation of subclavian vein catheterisation using supraclavicular versus infraclavicular approach

    PubMed Central

    Thakur, Anil; Kaur, Kiranpreet; Lamba, Aditya; Taxak, Susheela; Dureja, Jagdish; Singhal, Suresh; Bhardwaj, Mamta

    2014-01-01

    Background and Aims: Infraclavicular (IC) approach of subclavian vein (SCV) catheterisation is widely used as compared to supraclavicular (SC) approach. The aim of the study was to compare the ease of catheterisation of SCV using SC versus IC approach and also record the incidence of complications related to either approach, if any. Methods: In the study, 60 patients enrolled were randomly divided into two groups of 30 patients each. In Gp. SC right SCV catheterisation was performed using SC approach and in Gp. IC catheterisation was performed using IC approach. Access time, success rate of cannulation, number of attempts to cannulate vein, ease of guidewire and catheter insertion and length of catheter inserted and any associated complications were recorded. Results: The mean access time in group SC for SCV catheterisation was 4.30 ± 1.02 min compared to 6.07 ± 2.14 min in group IC. The overall success rate in catheterisation of the right SCV using SC approach (29 out of 30) was better as compared with group IC (27 out of 30) using IC approach. First attempt success in the SC group was 75.6% as compared with 59.25% in the IC group. All successful subclavian vein  catheterisations in SC group and IC group were associated with smooth insertion of guidewire following subclavian venipuncture. Conclusion: The SC approach of SCV catheterisation is comparable to IC approach in terms of landmarks accessibility, success rate and rate of complications. PMID:24963180

  9. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    PubMed

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  10. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    PubMed

    Lorente, Leonardo

    2016-05-04

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.

  11. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections

    PubMed Central

    Lorente, Leonardo

    2016-01-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  12. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    PubMed

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  13. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration

    PubMed Central

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-01-01

    Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505

  14. Portal Vein Embolization with Radiolabeled Polyvinyl Alcohol Particles in a Swine Model: Hepatic Distribution and Implications for Pancreatic Islet Cell Transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, Richard J., E-mail: drrichardowen@tbwifi.c; Mercer, John R.; Al-Saif, Faisal

    2009-05-15

    The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 {mu}m (Contour SE) and labeled with {sup 99m}Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for {sup 99m}Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulatemore » labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 {+-} 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with {sup 99m}Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-{mu}m particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.« less

  15. The Arm is Not the Leg: Pathophysiology, Diagnosis, and Management of Upper Extremity Deep Vein Thrombosis.

    PubMed

    Noyes, Adam M; Dickey, John

    2017-05-01

    Upper extremity deep venous thrombosis (UEDVT) involves thrombosis of the deep veins of the arm as they enter the thorax. They are increasing in frequency, largely due to the rising use of central venous catheters and implantable cardiac devices, and represent more than 10% of all DVT cases, Upper extremity deep venous thrombosis has been historically misunderstood when compared to lower extremity deep vein thrombosis (LEDVT). Their associated disease states may carry devastating complications, with mortality rates often higher than that of LEDVT. Thus, education on recognition, classification and management is critical to avoid long-term sequelae and mortality from UEDVT. [Full article available at http://rimed.org/rimedicaljournal-2017-05.asp].

  16. Endosonography and cytology in diagnosing and staging pancreatic body and tail carcinoma: Preliminary results of endosonographic guided puncture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tio, T.L.; Sie, L.H.; Tytgat, G.N.J.

    1993-01-01

    Endosonography was performed in diagnosing and staging pancreatic body and tail carcinoma in two patients. In the first case endoscopy, abdominal ultrasound, and computed tomography were nondiagnostic in diagnosing the origin of submucosal gastric abnormalities. Endosonography diagnosed a pancreatic tail carcinoma with submucosal gastric involvement, and this was confirmed by endosonographic-guided cytology. Fundus varices due to segmented splenic vein involvement were found. Surgery was not recommended due to the advanced disease. In the second case pancreatic body carcinoma was diagnosed by ERCP and computed tomography. Transcutaneous ultrasonographic-guided cytological puncture confirmed the diagnosis. Endosonography revealed additional information of segmental portal hypertensionmore » with fundic varices due to splenic vein involvement. Autopsy confirmed the endosonographic diagnosis. 18 refs., 5 figs.« less

  17. Internal jugular vein thrombosis associated with venous hypoplasia and protein S deficiency revealed by ultrasonography.

    PubMed

    Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung

    2011-12-01

    A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.

  18. [Chronic outcome of patients with paroxysmal atrial fibrillation post catheter ablation].

    PubMed

    Lin, Yu-bi; Xia, Yun-long; Gao, Lian-jun; Chu, Zhen-liang; Cong, Pei-xin; Chang, Dong; Yin, Xiao-meng; Zhang, Shu-long; Yang, Dong-Hui; Yang, Yan-Zong

    2009-12-01

    High short-term successful rate was reported for catheter ablation in patients with paroxysmal atrial fibrillation (AF), we analyzed the long-term outcome (success rate, anticoagulation therapy and embolism event, anti-arrhythmic therapy and death post procedure) of catheter ablation for paroxysmal AF in this study. From January 2000 to December 2004, 106 consecutive patients with drug-refractory paroxysmal AF underwent catheter ablation and were followed-up for (60.7 + or - 11.8) months. Segmental pulmonary vein isolation (SPVI) was routinely performed by radiofrequency energy under the guidance of circular mapping catheter. The patients were followed up with 24 h-holter, ECG, telephone or letter. Data on recurrence of AF, the anticoagulation medication and the incidence of embolism, anti-arrhythmic therapy were obtained. There were 9 patients lost to follow up. In the remaining 97 patients [65 males, (54.8 + or - 11.2) years old], 3 cases died from cancer, sinus rhythm was maintained in 68 patients (Group S, 72.3%) and AF recurrence evidenced in 26 patients (Group R, 27.7%). In Group S, 56 patients (82.4%) discontinued anticoagulation medication, and 12 patients continued to take aspirin. There was no embolism event in Group S during follow-up. In Group R, 1 patient continued to take warfarin; 11 patients continued to take aspirin and 2 patients suffered from cerebral embolism. Anticoagulation medication was discontinued in 14 patients (53.8%) and 1 patient suffered form cerebral embolism. The incidence of embolism event in Group R is significantly higher than in Group S (P < 0.01). More patients discontinued anti-arrhythmic medication in Group S than in Group R (80.9% vs. 56.0%, P < 0.05). Catheter ablation is associated with satisfactory long-term success rate, reduced anti-arrhythmia medication, improved quality of life in patients with paroxysmal AF.

  19. Achieving normothermia in patients with febrile subarachnoid hemorrhage: feasibility and safety of a novel intravascular cooling catheter.

    PubMed

    Badjatia, Neeraj; O'Donnell, Joan; Baker, John R; Huang, David; Ayata, Cenk; Greer, David M; Carter, Bob S; Ogilvy, Christopher S; McDonald, Colin T

    2004-01-01

    Fever is common and difficult to control in patients with subarachnoid hemorrhage (SAH). We have previously shown an inverse relationship between fever and outcome in patients with SAH. This was a prospective, single-arm, feasibility trial in which nine patients with SAH underwent temperature management using an intravascular cooling catheter (ICC) to restore and maintain 24 hours of normothermia (36.5 degrees+/-0.2 degrees C). Enrollment occurred after development of a fever of at least 38.3 degrees C within 7 days of SAH that was refractory to acetaminophen treatment. The ICC was placed at the bedside through an introducer sheath via the femoral vein into the inferior vena cava (IVC). Portable X-ray confirmed placement. Normothermia was achieved in seven of the nine patients treated (78%); it was achieved in 100% of the patients with a 14F catheter (n=4) and in 60% of the patients with a 9F catheter (n=5). The two patients not reaching normothermia were not adequately treated for shivering. All other patients reached normothermia irrespective of intubation status. Overall, normothermia was well tolerated and not discontinued because of discomfort or adverse events. Two incidences of deep vein thrombosis were diagnosis by ultrasound that were not associated with clinical sequelae, and IVC filters were placed. No unanticipated adverse events occurred. We have demonstrated that fever can be safely and effectively controlled in patients with SAH for at least 24 hours using an ICC. Future studies are needed to assess the effect of such sustained therapy on outcome in patients with SAH.

  20. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study.

    PubMed

    Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb

    2014-11-01

    This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.

  1. Diagnosis of catheter-related bloodstream infections among pediatric oncology patients lacking a peripheral culture, using differential time to detection.

    PubMed

    Gaur, Aditya H; Flynn, Patricia M; Heine, Daniel J; Giannini, Mary Anne; Shenep, Jerry L; Hayden, Randall T

    2005-05-01

    Current methods for in situ diagnosis of catheter-related bloodstream infections require concurrent collection of central venous catheter (CVC) and peripheral vein (PV) blood cultures. Both the pain and inconvenience of PV cultures are undesirable. A prospective study was conducted (August 2002 to March 2004) to assess the accuracy of diagnosing catheter-related bloodstream infections based on the difference in time to detection of blood cultures drawn concurrently from 2 lumens of a multilumen CVC. This difference in time to detection between 2 lumens was compared with results of the standard criterion with paired CVC and PV blood cultures. Twenty-one infectious episodes were categorized as catheter-related bloodstream infections and 38 as non-catheter-related bloodstream infections. With a cutoff in difference in time to detection between 2 lumens of > or =180 minutes, the sensitivity of this test to diagnose a catheter-related bloodstream infection was 61% (95% confidence interval, 39-80%) and the specificity was 94% (95% confidence interval, 82-99%). In 4 of 7 episodes with false-negative results, the colony counts in cultures from both lumens were >400 colony-forming units/mL (maximal value reported), indicating the limitation of this method when both lumens of the catheter are colonized. With the pretest probability of catheter-related bloodstream infections ranging from 28% to 54%, the positive predictive value of a difference in time to detection between 2 lumens of > or =180 minutes for diagnosis of catheter-related bloodstream infections ranged from 81% to 93% and the negative predictive value ranged from 67% to 86%. Within the context of its limitations, this novel method provides an alternative for diagnosing catheter-related bloodstream infections among patients with a CVC, without PV cultures.

  2. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    PubMed

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P < .001), but there was substantial overlap with pace capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete

  3. Detailed Surgical Anatomy of Prostate: Relationship between Urethra and Dorsal Vein Complex with Apex.

    PubMed

    Tunc, Lutfi; Akin, Yigit; Gumustas, Huseyin; Ak, Esat; Peker, Tuncay; Veneziano, Domenico; Guneri, Cagri

    2016-01-01

    To describe our surgical technique for dissecting the apex of prostate during robotic-assisted laparoscopic radical prostatectomy (RALP) and detailed surgical anatomy of prostate including relationship between urethra and dorsal vein complex with apex. In retrospective view of prospective collected data, 73 patients underwent RALP between December 2012 and September 2014. Surgical anatomy of prostate was revealed in all procedures. Quality of life (QoL) scores were assessed before, immediately after catheter removal, and 1 month after surgery. We divided urinary continence into 3 groups, as very early continence; continence at time of urethral catheter removal, early continent; and continence 1 month after surgery. The rest of the patients were accepted as continence. The mean follow-up was 10.2 ± 5.4 months and mean age was 61.5 ± 6.6. Maximum protection of urethra could be provided in all. Mean catheter removal was 8.9 ± 1.7 days, and all patients were continent at the time of catheter removal. QoL scores before RALP could be protected after surgery (p = 0.2). Neither conversion to open/conventional laparoscopic surgery nor complications related with bladder neck were detected. Our surgical technique can be a strong candidate for being a surgical technique for preserving urethra and very early continence could be provided after surgery. © 2016 S. Karger AG, Basel.

  4. Assessing the influence of risk factors on rates and dynamics of peripheral vein phlebitis: an observational cohort study.

    PubMed

    Mestre Roca, Gabriel; Berbel Bertolo, Cristina; Tortajada Lopez, Purificación; Gallemi Samaranch, Gema; Aguilar Ramirez, Mari Carmen; Caylà Buqueras, Joan; Rodríguez-Baño, Jesús; Martinez, José Antonio

    2012-07-21

    To assess the influence of risk factors on the rates and kinetics of peripheral vein phlebitis (PVP) development and its theoretical influence in absolute PVP reduction after catheter replacement. All peripheral short intravenous catheters inserted during one month were included (1201 catheters and 967 patients). PVP risk factors were assessed by a Cox proportional hazard model. Cumulative probability, conditional failure of PVP and theoretical estimation of the benefit from replacement at different intervals were performed. Female gender, catheter insertion at the emergency or medical-surgical wards, forearm site, amoxicillin-clavulamate or aminoglycosides were independent predictors of PVP with hazard ratios (95 confidence interval) of 1.46 (1.09-2.15), 1.94 (1.01-3.73), 2.51 (1.29-4.88), 1.93 (1.20-3.01), 2.15 (1.45-3.20) and 2.10 (1.01-4.63), respectively. Maximum phlebitis incidence was reached sooner in patients with ≥2 risk factors (days 3-4) than in those with <2 (days 4-5). Conditional failure increased from 0.08 phlebitis/one catheter-day for devices with ≤1 risk factors to 0.26 for those with ≥3. The greatest benefit of routine catheter exchange was obtained by replacement every 60h. However, this benefit differed according to the number of risk factors: 24.8% reduction with ≥3, 13.1% with 2, and 9.2% with ≤1. PVP dynamics is highly influenced by identifiable risk factors which may be used to refine the strategy of catheter management. Routine replacement every 72h seems to be strictly necessary only in high-risk catheters. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  5. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].

    PubMed

    Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S

    2015-01-01

    Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  6. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Minimally invasive vein therapy and treatment options for endovenous heat-induced thrombus.

    PubMed

    Frasier, Krista; Latessa, Victoria

    2008-06-01

    Radiofrequency ablation and endovenous laser therapy are types of minimally invasive techniques that have been used in the treatment of chronic venous insufficiency. In both procedures, high-intensity heat via thermal energy is produced and delivered via an endovenous catheter placed in the saphenous vein. This results in changes that therapeutically induce closure of the vein by denaturing the vessel wall with subsequent thrombus formation. Patients undergo ultrasound 48 to 72 hours postprocedure to confirm vessel occlusion and assess for possible extension of thrombus into the deep venous system. Thrombus is frequently visualized with the procedure in the tributaries, the venous dilations, and at times the saphenofemoral junction. In any other setting, thrombus at the saphenofemoral junction would warrant anticoagulation. However, the characteristics, composition, and behavior of endovenous heat-induced thrombus are different than de novo thrombosis. This postprocedure endovenous heat-induced thrombus is considered a normal consequence of the procedure and does not require traditional anticoagulation in most cases, depending on the location.

  8. Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.

    PubMed

    Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun

    2015-06-01

    Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.

  9. Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation.

    PubMed

    Nölker, Georg; Gutleben, Klaus-Jürgen; Muntean, Bogdan; Vogt, Jürgen; Horstkotte, Dieter; Dabiri Abkenari, Lara; Akca, Ferdi; Szili-Torok, Tamas

    2012-12-01

    Studies have shown that remote magnetic navigation is safe and effective for ablation of atrial arrhythmias, although optimal outcomes often require frequent manual manipulation of a circular mapping catheter. The Vdrive robotic system ('Vdrive') was designed for remote navigation of circular mapping catheters to enable a fully remote procedure. This study details the first human clinical experience with remote circular catheter manipulation in the left atrium. This was a prospective, multi-centre, non-randomized consecutive case series that included patients presenting for catheter ablation of left atrial arrhythmias. Remote systems were used exclusively to manipulate both the circular mapping catheter and the ablation catheter. Patients were followed through hospital discharge. Ninety-four patients were included in the study, including 23 with paroxysmal atrial fibrillation (AF), 48 with persistent AF, and 15 suffering from atrial tachycardias. The population was predominately male (77%) with a mean age of 60.5 ± 11.7 years. The Vdrive was used for remote navigation between veins, creation of chamber maps, and gap identification with segmental isolation. The intended acute clinical endpoints were achieved in 100% of patients. Mean case time was 225.9 ± 70.5 min. Three patients (3.2%) crossed over to manual circular mapping catheter navigation. There were no adverse events related to the use of the remote manipulation system. The results of this study demonstrate that remote manipulation of a circular mapping catheter in the ablation of atrial arrhythmias is feasible and safe. Prospective randomized studies are needed to prove efficiency improvements over manual techniques.

  10. Pelvic Vein Embolisation in the Management of Varicose Veins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.

    2008-11-15

    Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47more » (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.« less

  11. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    PubMed Central

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  12. Mid-term outcome of endovascular treatment for acute lower extremity deep venous thrombosis.

    PubMed

    Jiang, Kun; Li, Xiao-Qiang; Sang, Hong-Fei; Qian, Ai-Min; Rong, Jian-Jie; Li, Cheng-Long

    2017-04-01

    Purposes of the study To evaluate the benefit of stenting the iliac vein in patients with residual iliac vein stenosis treated with catheter-directed thrombolysis for acute iliofemoral deep venous thrombosis. Procedures In this randomized prospective study, patients with a first-time acute lower extremity deep venous thrombosis that had persisted <14 days were treated with catheter-directed thrombolysis. After catheter-directed thrombolysis, patients with >50% residual iliac vein stenosis were randomly divided into two groups: catheter-directed thrombolysis + Stent Group and catheter-directed thrombolysis Alone Group. Patients received urokinase thrombolysis and low-molecular-weight heparin/oral warfarin during the hospitalization period and were administrated oral warfarin after discharge. Cumulative deep vein patency, the Clinical Etiology Anatomic Pathophysiologic classification system, the Venous Clinical Severity Score and the Chronic Venous Insufficiency Questionnaire score were evaluated. Findings The cumulative deep vein patency rate was 74.07% in the catheter-directed thrombolysis + Stent Group and 46.59% in the catheter-directed thrombolysis Alone Group. The mean postoperative Clinical Etiology Anatomic Pathophysiologic classification and Venous Clinical Severity Score was significantly lower in the catheter-directed thrombolysis + Stent Group than in the catheter-directed thrombolysis Alone Group. The mean postoperative Chronic Venous Insufficiency Questionnaire score was significantly higher in the catheter-directed thrombolysis + Stent Group than the catheter-directed thrombolysis Alone Group. Conclusions Placement of an iliac vein stent in patients with residual iliac vein stenosis after catheter-directed thrombolysis for acute lower extremity deep venous thrombosis increases iliac vein patency and improves clinical symptoms and health-related quality of life at mid-term follow-up compared to patients treated with catheter

  13. Varicose Veins

    MedlinePlus

    ... This causes the veins to swell, which can lead to varicose veins. Varicose veins are very common. You are more at risk if you are older, are female, have obesity, don't exercise, or have a family history of varicose veins. They can also be more ...

  14. Catheter-related bloodstream infection.

    PubMed

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  15. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  16. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    PubMed

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and

  17. Post-fabrication QAC-functionalized thermoplastic polyurethane for contact-killing catheter applications.

    PubMed

    Zander, Zachary K; Chen, Peiru; Hsu, Yen-Hao; Dreger, Nathan Z; Savariau, Laura; McRoy, Willie C; Cerchiari, Alec E; Chambers, Sean D; Barton, Hazel A; Becker, Matthew L

    2018-05-11

    The use of catheters is ubiquitous in medicine and the incidence of infection remains unacceptably high despite numerous advances in functional surfaces and drug elution. Herein we report the use of a thermoplastic polyurethane containing an allyl ether side-chain functionality (allyl-TPU) that allows for rapid and convenient surface modification with antimicrobial reagents, post-processing. This post-processing functionalization affords the ability to target appropriate TPU properties and maintain the functional groups on the surface of the device where they do not affect bulk properties. A series of quaternary ammonium thiol compounds (Qx-SH) possessing various hydrocarbon tail lengths (8-14 carbons) were synthesized and attached to the surface using thiol-ene "click" chemistry. A quantitative assessment of the amount of Qx-SH available on the surface was determined using fluorescence spectroscopy and X-ray photoelectron spectroscopy (XPS). Contact-killing assays note the Q8-SH composition has the highest antimicrobial activity, and a live/dead fluorescence assay reveals rapid contact-killing of Staphylococcus aureus (>75% in 5 min) and Escherichia coli (90% in 10 min) inocula. Scale-up and extrusion of allyl-TPU provides catheter prototypes for biofilm formation testing with Pseudomonas aeruginosa, and surface-functionalized catheters modified with Q8-SH demonstrate their ability to reduce biofilm formation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The effects of vasoactive agents on flow through saphenous vein grafts during lower-extremity peripheral vascular surgery.

    PubMed

    Maslow, Andrew D; Bert, Arthur; Slaiby, Jeffrey; Carney, William; Marcaccio, Edward

    2007-06-01

    The purpose of this study was to assess the effects of hemodynamic alterations on vein graft flow during peripheral vascular surgery. It was hypothesized that vasopressors can be administered without compromising flow through the vein grafts. Tertiary care center, university medical center. Randomized placebo-controlled double-blinded study. The effects of phenylephrine, epinephrine, milrinone, intravenous fluid, and placebo on newly constructed peripheral vein grafts were assessed in 60 patients (12 patients in each of 5 groups). Systemic and central hemodynamics were measured by using intra-arterial and pulmonary artery catheters. Vein graft flow was measured by using a transultrasonic flow probe (Transultrasonic Inc, Ithaca, NY). Phenylephrine increased systemic mean blood pressure (mBP) (68.2-94.0 mmHg, p < 0.01), systemic vascular resistance (SVR) (1,091-1,696 dynes x sec x cm(-5), p < 0.001), and vein graft flow (39.5-58.9 mL/min, p < 0.01), whereas cardiac output remained unchanged. Epinephrine resulted in increased cardiac output (4.4-6.9 L/min, p < 0.01) and mBP (72.7-89.1 mmHg, p < 0.01), whereas vein graft flow was reduced in 6 of 12 patients. Intravenous fluid administration resulted in a relatively smaller increase in graft flow (37.6-46.0 mL/min, p < 0.05), an increase in cardiac output, and an insignificant decrease in SVR. Other treatments had either little or no effect on vein graft flow. The study hypothesis was partly supported. Although both phenylephrine and epinephrine increased blood pressure, only the former increased vein graft flow in all patients. In conjunction with increases in graft flow after fluid administration, these data suggest that factors affecting vein graft flow are not just simply related to systemic hemodynamics.

  19. Catheter associated urinary tract infections

    PubMed Central

    2014-01-01

    Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308

  20. Formation of thermal coagulum on multielectrode catheters during phased radiofrequency energy ablation of persistent atrial fibrillation.

    PubMed

    Debruyne, Philippe; Rossenbacker, Tom; Vankelecom, Bart; Charlier, Filip; Roosen, John; Ector, Bavo; Janssens, Luc

    2014-02-01

    Radiofrequency ablation (RFA) can unfavorably cause coagulum on the ablation electrode. The aim of this study was to assess this phenomenon on three different multielectrode catheters used to treat persistent atrial fibrillation with duty-cycled RFA. Twenty-six consecutive patients have been treated with the pulmonary vein ablation catheter (PVAC) and the multiarray ablation catheter (MAAC). In 13 patients, additional ablation with the multiarray septal catheter (MASC) has been performed. The multichannel RF generator GENius™ (Medtronic Inc., Minneapolis, MN, USA) independently delivered energy in a bipolar and unipolar mode (ratio of 4/1, 2/1, or 1/1) to any of the electrodes. Versions 14.2, 14.3, and 14.4 of the generator were used. Coagulum presence was determined postablation by careful visual inspection of the catheter electrodes. No coagulum formation was visualized on the PVACs. Coagulum formation was visualized in 59% of the electrodes of the MAACs using a 2/1 mode and the 14.2 software version versus 69% using the 14.4 version and a 2/1 mode (P = 0.7) versus 14% of the electrodes applying a 1/1 ratio and the 14.4 software version (P < 0.001). Duty-cycled RFA in 2/1 bipolar/unipolar ratio generates a substantial frequency of coagulum formation on the multielectrode catheters MAAC and MASC. The use of the 14.4 version of the software to drive the RF generator and the use of energy in the default 1/1 bipolar/unipolar ratio could significantly reduce the frequency of coagulum formation, but so far, could not completely overcome it. The PVAC did not form coagulum, regardless of generator version or energy ratio used. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  1. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients

    PubMed Central

    Karakitsos, Dimitrios; Labropoulos, Nicolaos; De Groot, Eric; Patrianakos, Alexandros P; Kouraklis, Gregorios; Poularas, John; Samonis, George; Tsoutsos, Dimosthenis A; Konstadoulakis, Manousos M; Karabinis, Andreas

    2006-01-01

    Introduction Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. Methods In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. Results There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). Conclusion The present data suggest that ultrasound

  2. Radiofrequency catheter ablation in patients with symptomatic atrial flutter/tachycardia after orthotopic heart transplantation.

    PubMed

    Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H

    2006-12-20

    Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of

  3. Hereditary and acquired thrombophilia in patients with upper extremity deep-vein thrombosis. Results from the MAISTHRO registry.

    PubMed

    Linnemann, Birgit; Meister, Florian; Schwonberg, Jan; Schindewolf, Marc; Zgouras, Dimitrios; Lindhoff-Last, Edelgard

    2008-09-01

    The prevalence of coagulation disorders in patients with upper extremity deep-vein thrombosis (UE-DVT) is unknown due to only a few observational studies of limited size reporting varying results. Therefore, we aimed to evaluate the prevalence of thrombophilia in patients with UE-DVT compared to patients with lower extremity deep vein thrombosis (LE-DVT). One hundred fifty consecutive patients (15 to 91 years of age) with UE-DVT were recruited from the MAISTHRO (MAin-ISar-THROmbosis) registry. Three hundred LE-DVT patients matched for gender and age served as controls. Thrombophilia screening included tests for the factor V Leiden mutation, the prothrombin G20210A mutation, antiphospholipid antibodies and factor VIII (FVIII), protein C, protein S and antithrombin activities. At least one thrombophilia was present in 34.2% of UE-DVT and 39.2% in UE-DVT that was unrelated to venous catheters relative to 55.3% in LE-DVT patients (p<0.001). In particular, a persistently elevated FVIII is less likely to be found in UE-DVT patients than in those with LE-DVT and is the only thrombophilia that is differentially expressed after controlling for established VTE risk factors [OR 0.46, (95% CI 0.25-0.83)]. Although less prevalent than in LE-DVT patients, thrombophilia is a common finding in patients with UE-DVT, especially in those with thrombosis that is unrelated to venous catheters.

  4. Avoiding the use of a femoral bridging catheter using a two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique.

    PubMed

    Yoon, William J; Lorelli, David R

    2015-01-01

    To evaluate a two-stage Hemodialysis Reliable Outflow (HeRO) implantation technique that avoids the use of a femoral bridging catheter versus the conventional one-stage technique requiring a bridging catheter in selected patients. A retrospective review was performed on 20 end-stage renal disease patients with an internal jugular vein (IJV) catheter selected for two-stage HeRO implantation at our institution between January 2010 and March 2013. The arterial graft component (AGC) was implanted without anastomosing it to the target artery (first stage). After AGC incorporation, the venous outflow component was inserted (second stage). The preexisting IJV catheter was maintained for hemodialysis access during the interstage period. Patient characteristics, patency using Kaplan-Meier method and infection rates were analyzed. A total of 17 patients with a mean age of 59 years (70.6% women) completed the two-stage procedure. During the interstage period (mean 12 weeks, range 4-22 weeks), no graft- or surgery-related infection occurred. The need of a femoral bridging catheter was avoided by utilizing the preexisting IJV dialysis catheter. The accumulated HeRO days were 3,916 days with a mean follow-up of 7.7 months (range 1-22.6 months). The HeRO-related infection rate was 0.3/1,000 days. The primary assisted and secondary patency rates at 6 months were 69% and 82%, respectively, which were similar to those of arteriovenous grafts. Staging conferred immediate vascular accessibility. Avoiding the use of a femoral bridging catheter using the two-stage technique may lower infection rate, with comparable primary assisted and secondary patency to arteriovenous grafts and added benefit of immediate cannulatability in this subset of patients.

  5. Brachial arteriovenous fistula as a complication of placement of a peripherally inserted central venous catheter: a case report and review of the literature.

    PubMed

    Tran, Hoang S; Burrows, Brian J; Zang, William A; Han, David C

    2006-09-01

    Peripherally inserted central venous catheter (PICC) lines have become a frequently used method of intravenous access for long-term administration of antibiotics, chemotherapy, and parenteral nutrition. Catheter-related complications involving the arterial tree are rare. We report a case of a 25-year-old woman with a history of difficult PICC line placement that presented with an arteriovenous fistula in the left arm. Duplex ultrasound confirmed the diagnosis of a brachial artery-to-brachial vein arteriovenous fistula (AVF), and the patient underwent surgical repair. To our knowledge, this is the first reported case of an AVF resulting from PICC line placement. Correction of AVF is indicated to alleviate symptoms as well as to prevent future complications.

  6. PRE-INOCULATION OF URINARY CATHETERS WITH ESCHERICHIA COLI 83972 INHIBITS CATHETER COLONIZATION BY ENTEROCOCCUS FAECALIS

    PubMed Central

    TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.

    2010-01-01

    Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359

  7. Devices and dressings to secure peripheral venous catheters to prevent complications.

    PubMed

    Marsh, Nicole; Webster, Joan; Mihala, Gabor; Rickard, Claire M

    2015-06-12

    A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically. To assess the effects of PVC dressings and securement devices on the incidence of PVC failure. We searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard

  8. The Nelaton Catheter Guard for Safe and Effective Placement of Subdural Drain for Two-Burr-Hole Trephination in Chronic Subdural Hematoma: A Technical Note.

    PubMed

    Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning

    2015-09-01

    For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.

  9. Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.

    PubMed

    Satyapal, K S

    1999-10-01

    level of entry of renal veins into IVC in foetuses. These findings are clinically important for the angiographer, catheter design, and planning porto-renal shunt procedures. Copyright 1999 Wiley-Liss, Inc.

  10. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation.

    PubMed

    Martinek, Martin; Lemes, Christine; Sigmund, Elisabeth; Derndorfer, Michael; Aichinger, Josef; Winter, Siegmund; Nesser, Hans-Joachim; Pürerfellner, Helmut

    2012-11-01

    Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  11. Characterization of central venous catheter-associated deep venous thrombosis in infants.

    PubMed

    Gray, Brian W; Gonzalez, Raquel; Warrier, Kavita S; Stephens, Lauren A; Drongowski, Robert A; Pipe, Steven W; Mychaliska, George B

    2012-06-01

    Deep venous thrombosis (DVT) is a frequent complication in infants with central venous catheters (CVCs). We performed this study to identify risk factors and risk-reduction strategies of CVC-associated DVT in infants. Infants younger than 1 year who had a CVC placed at our center from 2005 to 2009 were reviewed. Patients with ultrasonically diagnosed DVT were compared to those without radiographic evidence. Of 333 patients, 47% (155/333) had femoral, 33% (111/333) had jugular, and 19% (64/333) had subclavian CVCs. Deep venous thromboses occurred in 18% (60/333) of patients. Sixty percent (36/60) of DVTs were in femoral veins. Femoral CVCs were associated with greater DVT rates (27%; 42/155) than jugular (11%; 12/111) or subclavian CVCs (9%; 6/64; P < .01). There was a 16% DVT rate in those with saphenofemoral Broviac CVCs vs 83% (20/24) in those with percutaneous femoral lines (P < .01). Multilumen CVCs had higher DVT rates than did single-lumen CVCs (54% vs 6%, P < .01), and mean catheter days before DVT diagnosis was shorter for percutaneous lines than Broviacs (13 ± 17 days vs 30 ± 37 days, P = .02). Patients with +DVT had longer length of stay (86 ± 88 days vs 48 ± 48 days, P < .01) and higher percentage of intensive care unit admission (82% vs 70%, P = .02). Deep venous thrombosis reduction strategies in infants with CVCs include avoiding percutaneous femoral and multilumen CVCs, screening percutaneous lines, and early catheter removal. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Influence of arm position on catheter placement during real-time ultrasound-guided right infraclavicular proximal axillary venous catheterization.

    PubMed

    Ahn, J H; Kim, I S; Shin, K M; Kang, S S; Hong, S J; Park, J H; Kim, H J; Lee, S H; Kim, D Y; Jung, J H

    2016-03-01

    Real-time ultrasound-guided infraclavicular proximal axillary venous catheterization is used in many clinical situations and provides the advantages of catheter stabilization, a reduced risk of catheter-related infection, and comfort for the patient without limitation of movement. However, unintended catheter tip dislocation and accidental arterial puncture occur occasionally. This study was designed to investigate the influence of arm position on catheter placement and complications. Patients were randomized to either the neutral group (n=240) or the abduction group (n=241). In the neutral group, patients were positioned with the head and shoulders placed in an anatomically neutral position and the arms kept by the side during catheterization. In the abduction group, the right upper arm was abducted at 90° from the trunk during catheterization. After real-time ultrasound-guided catheterization was carried out in the right infraclavicular proximal axillary vein, misplacement of the catheter and all complications were evaluated with ultrasound and chest radiography. The success rate of complete catheterization before evaluating the placement of the catheter was high in both groups (97.1 vs 98.8%, P=not significant). The incidence of accidental arterial puncture was not different (1.7 vs 0%, P=not significant). The incidence of misplacement of the catheter was higher in the neutral group than in the abduction group (3.9 vs 0.4%, P=0.01). There were no complications, such as haemothorax, pneumothorax, or injury to the brachial plexus and phrenic nerve, in either group. Upper arm abduction may minimize the risk of misplacement of the catheter during real-time ultrasound-guided infraclavicular proximal axillary venous catheterization. The trial was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp. Identifier: KCT0001417. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia

  13. Deep Vein Thrombosis

    MedlinePlus

    Deep vein thrombosis, or DVT, is a blood clot that forms in a vein deep in the body. Most ... vein swells, the condition is called thrombophlebitis. A deep vein thrombosis can break loose and cause a serious problem ...

  14. Catheter interventional treatment of congenital portosystemic venous shunts in childhood.

    PubMed

    Knirsch, Walter; Benz, Dominik C; Bühr, Patrick; Quandt, Daniel; Weber, Roland; Kellenberger, Christian; Braegger, Christian P; Kretschmar, Oliver

    2016-06-01

    The study aimed on the catheter interventional treatment of congenital portosystemic venous shunt (CPSVS) in childhood and the impact on vascular growth of hypoplastic portal veins. Clinical course and follow up of partial or complete closure of CPSVS are described. CPSVS is a very rare vascular malformation of the portal venous drainage resulting in potentially life threatening abdominal, pulmonary, cerebral, and cardiac complications. The anatomic type, clinical course, and diagnosis must be determined for optimal management. Single centre case series. Eight (6 female) children with extrahepatic (n = 5) and intrahepatic (n = 3) CPSVS were diagnosed invasively by catheterization, including test balloon occlusion of the shunt and simultaneous retrograde angiography, and treated by catheter interventions (n = 5) with partial (n = 2) and complete (n = 3) occlusion of CPSVS at a median age of 3.9 years (range 0.7-21). Congenital heart disease (CHD) was the most frequent associated organ manifestation (n = 5) followed by mild to severe pulmonary arterial hypertension (n = 4), hepatopulmonary syndrome (n = 2), and portosystemic encephalopathy (n = 1). CHD was simple (n = 3) or complex type (n = 2). Three patients were untreated so far, because they were in excellent clinical condition at an age <1 year, refused treatment, or planned for later treatment. Accurate invasive diagnosis of CPSVS with test balloon occlusion of the shunt is mandatory to depict the anatomic situation. Catheter interventional treatment of CPSVS offers a feasible and safe approach with complete or partial closure of the vascular malformation inducing potentially significant vascular growth of a former hypoplastic portal venous system. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  15. Indwelling catheter care

    MedlinePlus

    ... it overnight. You will be shown how to disconnect the bags from the Foley catheter in order ... bags through a separate valve without needing to disconnect the bag from the Foley catheter. Making Sure ...

  16. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement

    PubMed Central

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically. PMID:29284881

  17. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    PubMed

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  18. Atrial rhythm influences catheter tissue contact during radiofrequency catheter ablation of atrial fibrillation: comparison of contact force between sinus rhythm and atrial fibrillation.

    PubMed

    Matsuda, Hisao; Parwani, Abdul Shokor; Attanasio, Philipp; Huemer, Martin; Wutzler, Alexander; Blaschke, Florian; Haverkamp, Wilhelm; Boldt, Leif-Hendrik

    2016-09-01

    Catheter tissue contact force (CF) is an important factor for durable lesion formation during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Since CF varies in the beating heart, atrial rhythm during RFCA may influence CF. A high-density map and RFCA points were obtained in 25 patients undergoing RFCA of AF using a CF-sensing catheter (Tacticath, St. Jude Medical). The operators were blinded to the CF information. Contact type was classified into three categories: constant, variable, and intermittent contact. Average CF and contact type were analyzed according to atrial rhythm (SR vs. AF) and anatomical location. A total of 1364 points (891 points during SR and 473 points during AF) were analyzed. Average CFs showed no significant difference between SR (17.2 ± 11.3 g) and AF (17.2 ± 13.3 g; p = 0.99). The distribution of points with an average CF of ≥20 and <10 g also showed no significant difference. However, the distribution of excessive CF (CF ≥40 g) was significantly higher during AF (7.4 %) in comparison with SR (4.2 %; p < 0.05). At the anterior area of the right inferior pulmonary vein (RIPV), the average CF during AF was significantly higher than during SR (p < 0.05). Constant contact was significantly higher during AF (32.2 %) when compared to SR (9.9 %; p < 0.01). Although the average CF was not different between atrial rhythms, constant contact was more often achievable during AF than it was during SR. However, excessive CF also seems to occur more frequently during AF especially at the anterior part of RIPV.

  19. Central venous catheter-related infections in patients receiving short-term hemodialysis therapy: incidence, associated factors, and microbiological aspects.

    PubMed

    Menegueti, Mayra Gonçalves; Betoni, Natália Cristina; Bellissimo-Rodrigues, Fernando; Romão, Elen Almeida

    2017-01-01

    Bloodstream infections are the second most common cause of death among patients on hemodialysis. This study aimed to evaluate the incidence of and risk factors associated with central venous catheter-related infections in patients undergoing hemodialysis, and to identify and characterize the type and antimicrobial susceptibility profiles of the primary microorganisms isolated during one year of follow-up. A prospective cohort study was conducted in 2014 in a hemodialysis referral center. We included 200 outpatients with acute kidney injury who had no permanent venous access. A nurse assessed the patients for signs of infection three times per week during dressing changes. The clinicopathologic characteristics of patients with and without local or systemic infection were compared. Fifty-five episodes of catheter-related infections occurred in 43 (22%) patients; 38 (69%) were bloodstream infections and 17 (31%) were local infections. Thirty-two (75%) patients with infection had femoral vein catheter placement. In total, 6,240 hemodialysis sessions were performed; the rates of primary bloodstream and local infection were 6.1 and 2.7 episodes per 1,000 patients on daily dialysis, respectively. In the univariate analysis, diabetes was significantly associated with the development of infection, while level of education, ethnicity, age, and sex were not. Gram-negative bacteria were primarily isolated from blood culture specimens (55% of samples). Of the Gram-negative isolates, 56% were resistant to the carbapenems. We identified a high incidence of catheter-related infections caused by resistant microorganisms in patients undergoing hemodialysis via central venous catheters.

  20. A prospective clinical trial to assess peripheral venous catheter-related phlebitis using needleless connectors in a surgery department.

    PubMed

    Ronen, Ohad; Shlomo, Fanny; Ben-Adiva, Gila; Edri, Zehava; Shema-Didi, Lilach

    2017-10-01

    The use of intravascular catheters is often complicated by phlebitis, which is associated with increased morbidity and extended duration of hospitalization. We conducted a study to investigate the impact of needleless intravenous access devices on the rate of phlebitis in peripheral venous catheters (PVCs). We prospectively recruited patients in 2 phases. The first group was treated with a regular cap, and the second group was treated with a needleless connector. The incidence of catheter-related phlebitis (CRP) was recorded as the primary end point. A total of 620 PVCs using regular caps were inserted into 340 patients and CRP rates were recorded. In the second phase of the study, 169 PVCs using needleless connectors were inserted into 135 patients. In the group treated with the regular cap, the CRP rate was 60% compared with 7% in the group treated with the needleless cap (P <.001). Consequently, the number of catheter replacements was decreased from 1.9 on average to 1.3 (P <.001). In both phases, patients who developed phlebitis had a statistically significant longer mean hospitalization period (P <.001), as were patients in the regular cap group (P <.01). The use of needleless connectors was found to be associated with a significant reduction of CRP in peripheral veins in a surgery department setting. The decreased morbidity resulted in a lower number of catheter replacements and duration of hospitalization. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. IR Approaches to Difficult Removals of Totally Implanted Venous Access Port Catheters in Children: A Single-Center Experience.

    PubMed

    Patel, Premal Amrishkumar; Parra, Dimitri A; Bath, Ramnik; Amaral, Joao G; Temple, Michael J; John, Philip R; Connolly, Bairbre L

    2016-06-01

    To identify factors associated with adherence of implanted venous access port catheters in children and describe technical strategies for removing "stuck" ports. A retrospective single-center review of port removals was conducted between 2003 and 2012. Cases were identified through radiology reports. Clinical details (eg, demographics, disease, port dwell time, interventional techniques) were obtained through patient charts. Cases were classified as difficult removals if there was documented adherence to soft tissues or vein, or simple removals if no difficulty was recorded. Difficult removals were categorized and graded on increasing invasiveness of techniques required. Successful removal was defined as complete removal of the port catheter. Difficult removals were compared with simple removals for factors associated with difficult removal. Of all removals (N = 1,306), 58 were classified as difficult removals (4%). Using various techniques, 57 of 58 (98%) adherent port catheters were successfully removed. Factors identified with difficult removals included primary diagnosis of acute lymphoblastic leukemia (ALL) (78% vs 37%, P < .0001), age at insertion (3.7 y vs 5.4 y, P = .0019), and port dwell time (median 1,087 d vs 616 d, P < .0001). Difficulty removing port catheters in children is uncommon. Port catheters can usually be removed successfully using various IR techniques ranging in invasiveness. There is an association of difficult removal with early age at insertion, ALL diagnosis, and long port dwell time. Awareness of these factors may help physicians inform parents of potential difficulties and plan the removal procedure. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  2. Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study.

    PubMed

    Tamura, Akio; Kato, Kenichi; Kamata, Masayoshi; Suzuki, Tomohiro; Suzuki, Michiko; Nakayama, Manabu; Tomabechi, Makiko; Nakasato, Tatsuhiko; Ehara, Shigeru

    2017-02-01

    To compare the 24-gauge side-holes catheter and conventional 22-gauge end-hole catheter in terms of safety, injection pressure, and contrast enhancement on multi-detector computed tomography (MDCT). In a randomized single-center study, 180 patients were randomized to either the 24-gauge side-holes catheter or the 22-gauge end-hole catheter groups. The primary endpoint was safety during intravenous administration of contrast material for MDCT, using a non-inferiority analysis (lower limit 95% CI greater than -10% non-inferiority margin for the group difference). The secondary endpoints were injection pressure and contrast enhancement. A total of 174 patients were analyzed for safety during intravenous contrast material administration for MDCT. The overall extravasation rate was 1.1% (2/174 patients); 1 (1.2%) minor episode occurred in the 24-gauge side-holes catheter group and 1 (1.1%) in the 22-gauge end-hole catheter group (difference: 0.1%, 95% CI: -3.17% to 3.28%, non-inferiority P=1). The mean maximum pressure was higher with the 24-gauge side-holes catheter than with the 22-gauge end-hole catheter (8.16±0.95kg/cm 2 vs. 4.79±0.63kg/cm 2 , P<0.001). The mean contrast enhancement of the abdominal aorta, celiac artery, superior mesenteric artery, and pancreatic parenchyma in the two groups were not significantly different. In conclusion, our study showed that the 24-gauge side-holes catheter is safe and suitable for delivering iodine with a concentration of 300mg/mL at a flow-rate of 3mL/s, and it may contribute to the care of some patients, such as patients who have fragile and small veins. (Trial registration: UMIN000023727). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Online Measurement of Microembolic Signal Burden by Transcranial Doppler during Catheter Ablation for Atrial Fibrillation-Results of a Multicenter Trial.

    PubMed

    von Bary, Christian; Deneke, Thomas; Arentz, Thomas; Schade, Anja; Lehrmann, Heiko; Fredersdorf, Sabine; Baldaranov, Dobri; Maier, Lars; Schlachetzki, Felix

    2017-01-01

    Left atrial pulmonary vein isolation (PVI) is an accepted treatment option for patients with symptomatic atrial fibrillation (AF). This procedure can be complicated by stroke or silent cerebral embolism. Online measurement of microembolic signals (MESs) by transcranial Doppler (TCD) may be useful for characterizing thromboembolic burden during PVI. In this prospective multicenter trial, we investigated the burden, characteristics, and composition of MES during left atrial catheter ablation using a variety of catheter technologies. PVI was performed in a total of 42 patients using the circular-shaped multielectrode pulmonary vein ablation catheter (PVAC) technology in 23, an irrigated radiofrequency (IRF) in 14, and the cryoballoon (CB) technology in 5 patients. TCD was used to detect the total MES burden and sustained thromboembolic showers (TESs) of >30 s. During TES, the site of ablation within the left atrium was registered. MES composition was classified manually into "solid," "gaseous," or "equivocal" by off-line expert assessment. The total MES burden was higher when using IRF compared to CB (2,336 ± 1,654 vs. 593 ± 231; p  = 0.007) and showed a tendency toward a higher burden when using IRF compared to PVAC (2,336 ± 1,654 vs. 1,685 ± 2,255; p  = 0.08). TES occurred more often when using PVAC compared to IRF (1.5 ± 2 vs. 0.4 ± 1.3; p  = 0.04) and most frequently when ablation was performed close to the left superior pulmonary vein (LSPV). Of the MES, 17.004 (23%) were characterized as definitely solid, 13.204 (18%) as clearly gaseous, and 44.366 (59%) as equivocal. We investigated the burden and characteristics of MES during left atrial catheter ablation for AF. All ablation techniques applied in this study generated a relevant number of MES. There was a significant difference in total MES burden using IRF compared to CB and a tendency toward a higher burden using IRF compared to PVAC. The highest TES burden was

  4. Determining the best catheter for sonohysterography.

    PubMed

    Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B

    2001-09-01

    To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

  5. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    PubMed

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  6. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    PubMed

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  7. Rational choice of peritoneal dialysis catheter.

    PubMed

    Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio

    2007-06-01

    The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.

  8. Acute urinary retention: which catheter?

    PubMed Central

    Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.

    1988-01-01

    There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328

  9. The identification of conduction gaps after pulmonary vein isolation using a new electroanatomic mapping system.

    PubMed

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2017-11-01

    The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  11. Implantation of active fixation leads in coronary veins for left ventricular stimulation: report of five cases.

    PubMed

    Hansky, Bert; Vogt, Juergen; Gueldner, Holger; Schulte-Eistrup, Sebastian; Lamp, Barbara; Heintze, Johannes; Horstkotte, Dieter; Koerfer, Reiner

    2007-01-01

    Securing transvenous left ventricular (LV) pacing leads without an active fixation mechanism in proximal coronary vein (CV) segments is usually challenging and frequently impossible. We investigated how active fixation leads can be safely implanted in this location, how to avoid perforating the free wall of the CV, and how to recognize and respond to perforations. In five patients with no alternative to LV pacing from proximal CV segments, 4 Fr SelectSecure (Medtronic, Minneapolis, MN, USA) leads, which have a fixed helix, were implanted through a modified 6 Fr guide catheter with a pre-shaped tip (Launcher, Medtronic). Active fixation leads were successfully implanted in proximal CVs in five patients. There were no complications. Acute and chronic pacing thresholds were comparable to those of conventional CV leads. The pre-shaped guide catheter tip remains in close proximity to the myocardial aspect of the CV, directing the lead helix toward a safe implantation site. If only proximal CV pacing sites are available, 4 Fr SelectSecure leads can be safely implanted through a modified Launcher guide catheter, avoiding more invasive implantation techniques. Other than venous stenting or implantation of leads with retractable tines, SelectSecure leads are expected to remain extractable.

  12. Does a patent foramen ovale matter when using a remote-controlled magnetic system for pulmonary vein isolation?

    PubMed

    Gate-Martinet, Alexie; Da Costa, Antoine; Romeyer-Bouchard, Cécile; Bisch, Laurence; Levallois, Marie; Isaaz, Karl

    2014-02-01

    Pulmonary vein isolation (PVI) takes longer when using a patent foramen ovale (PFO) compared with a transseptal puncture in paroxysmal atrial fibrillation (AF) with manual catheter ablation. To our knowledge, no data exist concerning the impact of a PFO on AF ablation procedure variables when using a remote magnetic navigation (RMN) system. To assess the impact of a PFO when using an RMN system in patients requiring AF ablation. Between December 2011 and December 2012, catheter ablation was performed remotely using the CARTO(®) 3 system in 167 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power ≤ 35 W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation for all patients and including additional lesion lines (left atrial roof) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data. Mean age 58±10 years; 18% women; 107 (64%) patients with symptomatic paroxysmal AF; 60 (36%) with persistent AF; CHA2DS2-VASc score 1.2 ± 1. The PFO presence was evidenced in 49/167 (29.3%) patients during the procedure but in only 26/167 (16%) by transoesophageal echocardiography. Median procedure time 2.5 ± 1 hours; median total X-ray exposure time 14 ± 7 minutes; transseptal puncture and catheter positioning time 7.5 ± 5 minutes; left atrium electroanatomical reconstruction time 3 ± 2.3 minutes; catheter ablation time 3 ± 3 minutes. No procedure time or X-ray exposure differences were observed between patients with or without a PFO during magnetic navigation catheter ablation. X-ray exposure time was significantly reduced using a PFO compared with double transseptal puncture access. A PFO does not affect magnetic navigation during AF ablation; procedure times and X-ray exposure were similar. Septal catheter probing is mandatory to limit X-ray exposure and prevent potential complications

  13. Accidental dural puncture, postdural puncture headache, intrathecal catheters, and epidural blood patch: revisiting the old nemesis.

    PubMed

    Kaddoum, Roland; Motlani, Faisal; Kaddoum, Romeo N; Srirajakalidindi, Arvi; Gupta, Deepak; Soskin, Vitaly

    2014-08-01

    One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.

  14. Inspiration from nature: dynamic modelling of the musculoskeletal structure of the seahorse tail.

    PubMed

    Praet, Tomas; Adriaens, Dominique; Van Cauter, Sofie; Masschaele, Bert; De Beule, Matthieu; Verhegghe, Benedict

    2012-10-01

    Technological advances are often inspired by nature, considering that engineering is frequently faced by the same challenges as organisms in nature. One such interesting challenge is creating a structure that is at the same time stiff in a certain direction, yet flexible in another. The seahorse tail combines both radial stiffness and bending flexibility in a particularly elegant way: even though the tail is covered in a protective armour, it still shows sufficient flexibility to fully function as a prehensile organ. We therefore study the complex mechanics and dynamics of the musculoskeletal system of the seahorse tail from an engineering point of view. The seahorse tail derives its combination of flexibility and resilience from a chain of articulating skeletal segments. A versatile dynamic model of those segments was constructed, on the basis of automatic recognition of joint positions and muscle attachments. Both muscle structures that are thought to be responsible for ventral and ventral-lateral tail bending, namely the median ventral muscles and the hypaxial myomere muscles, were included in the model. Simulations on the model consist mainly of dynamic multi-body simulations. The results show that the sequential structure of uniformly shaped bony segments can remain flexible because of gliding joints that connect the corners of the segments. Radial stiffness on the other hand is obtained through the support that the central vertebra provides to the tail plating. Such insights could help in designing biomedical instruments that specifically require both high bending flexibility and radial stiffness (e.g. flexible stents and steerable catheters). Copyright © 2012 John Wiley & Sons, Ltd.

  15. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  16. Radiofrequency catheter ablation versus balloon cryoablation of atrial fibrillation: markers of myocardial damage, inflammation, and thrombogenesis.

    PubMed

    Antolič, Bor; Pernat, Andrej; Cvijić, Marta; Žižek, David; Jan, Matevž; Šinkovec, Matjaž

    2016-07-01

    Evidence from animal and human studies suggests that cryoablation might be associated with a lesser inflammatory response and activation of coagulation compared with radiofrequency ablation. The study was aimed at comparing the effect of cryoballoon and radiofrequency catheter ablation of paroxysmal atrial fibrillation on markers of myocardial damage, inflammation, and activation of coagulation. Forty-one patients received either cryoballoon (n = 23) or radiofrequency (n = 18) ablation of atrial fibrillation. We measured troponin I, high-sensitivity CRP, and interleukin 6 at baseline from the cubital vein, and from the right and left atrium before and after ablation, and from the cubital vein the following day. Prothrombin fragments 1 + 2, soluble P‑selectin, and D‑dimer were measured before and after ablation from both atria. We observed higher troponin I release in the cryoballoon than in the radiofrequency group (7.01 mcg/l (interquartile range [IQR]: 5.30-9.09) vs 2.32 mcg/l (IQR: 1.45-2.98), p < 0.001). The levels of inflammatory markers (high-sensitivity CRP and interleukin 6) in the two groups were comparable, as were the levels of markers of coagulation activation. Procedure duration, fluoroscopy times, and mid-term success (23 months, IQR 7-32) of the two groups were also comparable. Cryoballoon ablation of atrial fibrillation causes more significant myocardial damage, that is, more extensive ablation lesions, compared with radiofrequency catheter ablation. However, no major differences between these two ablation techniques with regard to the inflammatory response and activation of the coagulation system were observed.

  17. Percutaneous intraportal application of adipose tissue-derived mesenchymal stem cells using a balloon occlusion catheter in a porcine model of liver fibrosis.

    PubMed

    Avritscher, Rony; Abdelsalam, Mohamed E; Javadi, Sanaz; Ensor, Joe; Wallace, Michael J; Alt, Eckhard; Madoff, David C; Vykoukal, Jody V

    2013-12-01

    To investigate the safety and effectiveness of a novel endovascular approach for therapeutic cell delivery using a balloon occlusion catheter in a large animal model of liver fibrosis. Transcatheter arterial embolization with ethiodized oil (Ethiodol) and ethanol was used to induce liver damage in 11 pigs. Mesenchymal stem cells (MSCs) were harvested from adipose tissue and engineered to express green fluorescent protein (GFP). A balloon occlusion catheter was positioned in the bilateral first-order portal vein branches 2 weeks after embolization to allow intraportal application of MSCs in six experimental animals. MSCs were allowed to dwell for 10 minutes using prolonged balloon inflation. Five control animals received a sham injection of normal saline in a similar fashion. Hepatic venous pressure gradient (HVPG) was measured immediately before necropsy. Specimens from all accessible lobes were obtained with ultrasound-guided percutaneous 18-gauge biopsy 2 hours after cell application. All animals were euthanized within 4 weeks. Fluorescent microscopy was used to assess the presence and distribution of cells. Liver injury and fibrosis were successfully induced in all animals. MSCs (6-10 × 10(7)) were successfully delivered into the portal vein in the six experimental animals. Cell application was not associated with vascular complications. HVPG showed no instances of portal hypertension. GFP-expressing MSCs were visualized in biopsy specimens and were distributed primarily within the sinusoidal spaces; however, 4 weeks after implantation, MSCs could not be identified in histologic specimens. A percutaneous endovascular approach for cell delivery using a balloon occlusion catheter proved safe for intraportal MSC application in a large animal model of liver fibrosis. © 2013 SIR Published by SIR All rights reserved.

  18. Pulmonary Hypertension due to Radiofrequency Catheter Ablation (RFCA) for Atrial Fibrillation: The Lungs, the Atrium or the Ventricle?

    PubMed

    Verma, Isha; Tripathi, Hemantkumar; Sikachi, Rutuja Rajanikant; Agrawal, Abhinav

    2016-12-01

    Atrial fibrillation is the most common heart rhythm disorder in United States, characterised by rapid and irregular beating of both the atria resulting in the similar ventricular response. While rate and rhythm control using pharmacological regimens remain the primary management strategies in these patients, radiofrequency catheter ablation (RFCA) is rapidly rising as an alternative modality of treatment. Increase in the incidence of RFCA has shed light on complications associated with this procedure. Pulmonary hypertension (PH) is one of the long-term complications that has been observed postcatheter ablation. There have been multiple mechanisms which have been proposed to explain these elevated pulmonary pressures. These include the involvement of the lungs due to pulmonary vein stenosis, pulmonary vein occlusion and, rarely, pulmonary embolism. Radiofrequency catheter ablation can also lead to scarring of the atrium which can cause left atrial diastolic dysfunction leading to elevated pulmonary pressures. Recently, it was also proposed that elevated pulmonary pressure was related to the unmasking of left ventricular diastolic dysfunction occurring after this procedure. In this article, we review all the mechanisms that are associated with the development of pulmonary hypertension in patients undergoing RCFA for atrial fibrillation and the approach to diagnosis and management of such patients. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  19. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    PubMed

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  20. Differentiation of deep venous thrombosis from femoral vein mixing artifact on routine abdominopelvic CT.

    PubMed

    Doshi, Ankur M; Hoffman, David; Kierans, Andrea S; Ream, Justin M; Rosenkrantz, Andrew B

    2015-10-01

    The objective of this study is to assess the performance of qualitative and quantitative imaging features for the differentiation of deep venous thrombosis (DVT) from mixing artifact on routine portal venous phase abdominopelvic CT. This retrospective study included 40 adult patients with a femoral vein filling defect on portal venous phase CT and a Duplex ultrasound (n = 36) or catheter venogram (n = 4) to confirm presence or absence of DVT. Two radiologists (R1, R2) assessed the femoral veins for various qualitative and quantitative features. 60% of patients were confirmed to have DVT and 40% had mixing artifact. Features with significantly greater frequency in DVT than mixing artifact (all p ≤ 0.006) were central location (R1 90% vs. 28%; R2 96% vs. 31%), sharp margin (R1 83% vs. 28%; R2 96% vs. 31%), venous expansion (R1 48% vs. 6%, R2 56% vs. 6%), and venous wall enhancement (R1 62% vs. 0%; R2 48% vs. 0%). DVT exhibited significantly lower mean attenuation than mixing artifact (R1 42.1 ± 20.2 vs. 57.1 ± 23.6 HU; R2 43.6 ± 19.4 vs. 58.8 ± 23.4 HU, p ≤ 0.031) and a significantly larger difference in vein diameter compared to the contralateral vein (R1 0.4 ± 0.4 vs. 0.1 ± 0.2 cm; R2 0.3 ± 0.4 vs. 0.0 ± 0.1 cm, p ≤ 0.026). At multivariable analysis, central location and sharp margin were significant independent predictors of DVT for both readers (p ≤ 0.013). Awareness of these qualitative and quantitative imaging features may improve radiologists' confidence for differentiating femoral vein DVT and mixing artifact on routine portal venous phase CT. However, given overlap with mixing artifact, larger studies remain warranted.

  1. Improvements of deep vein reflux following radiofrequency ablation for saphenous vein incompetence.

    PubMed

    Kim, Suh Min; Jung, In Mok; Chung, Jung Kee

    2017-02-01

    Objectives The aim of this study was to describe the changes of deep vein reflux after radiofrequency ablation for great saphenous vein incompetence. Method The data on 139 limbs which were treated with radiofrequency ablation for great saphenous vein incompetence were prospectively collected and reviewed. Results Deep vein reflux was present in 43 of 139 limbs (30.9%). There were no significant differences in the rate of successful closure, the incidence of procedure-related complications, and the improvements of symptoms and quality of life between the limbs with or without deep vein reflux. With a mean follow-up of 5.9 months, the peak reflux velocity and duration of reflux were improved in all limbs with deep vein reflux and it was completely corrected in 13 limbs (30.2%) after radiofrequency ablation. Conclusions The presence of deep vein reflux does not affect the treatment outcomes of radiofrequency ablation for great saphenous vein incompetence and is improved in all patients. Deep vein reflux is not a barrier to performing radiofrequency ablation.

  2. [Urinary catheter biofilm infections].

    PubMed

    Holá, V; Růzicka, F

    2008-04-01

    Urinary tract infections, most of which are biofilm infections in catheterized patients, account for more than 40% of hospital infections. Bacterial colonization of the urinary tract and catheters causes not only infection but also other complications such as catheter blockage by bacterial encrustation, urolithiasis and pyelonephritis. About 50% of long-term catheterized patients face urinary flow obstruction due to catheter encrustation, but no measure is currently available to prevent it. Encrustation has been known either to result from metabolic dysfunction or to be of microbial origin, with urease positive bacterial species implicated most often. Infectious calculi account for about 15-20% of all cases of urolithiasis and are often associated with biofilm colonization of a long-term indwelling urinary catheter or urethral stent. The use of closed catheter systems is helpful in reducing such problems; nevertheless, such a system only delays the inevitable, with infections emerging a little later. Various coatings intended to prevent the bacterial adhesion to the surface of catheters and implants and thus also the emergence of biofilm infections, unfortunately, do not inhibit the microbial adhesion completely and permanently and the only reliable method for biofilm eradication remains the removal of the foreign body from the patient.

  3. [Rotational stability of angiography catheters].

    PubMed

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  4. How to perform posterior wall isolation in catheter ablation for atrial fibrillation.

    PubMed

    Sugumar, Hariharan; Thomas, Stuart P; Prabhu, Sandeep; Voskoboinik, Aleksandr; Kistler, Peter M

    2018-02-01

    Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described. © 2017 Wiley Periodicals, Inc.

  5. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    PubMed

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  6. Bladder Morphology Using 2 Different Catheter Designs

    ClinicalTrials.gov

    2017-04-10

    Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence

  7. Embryo Transfer Catheters: Softer is Easier.

    PubMed

    Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G

    2015-11-01

    This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.

  8. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

    PubMed Central

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most

  9. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases.

    PubMed

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8 ± 14 [17-84] years old), with mean EF of 0.66 ± 0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. The mean esophageal displacement was 4 to 9.1cm (5.9 ± 0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11 ± 0.13ºC versus 1.1 ± 0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was

  10. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Catheter-related bloodstream infection with removal of catheter in pediatric oncology patients: a 10-year experience in Taiwan.

    PubMed

    Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih

    2012-04-01

    Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.

  12. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy - Case report.

    PubMed

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B

    2014-12-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  13. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?

    PubMed

    Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio

    2014-07-01

    Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. TROPICS 1: a phase III, randomized, double-blind, placebo-controlled study of tenecteplase for restoration of function in dysfunctional central venous catheters.

    PubMed

    Gabrail, Nashat; Sandler, Eric; Charu, Veena; Anas, Nick; Lim, Eduardo; Blaney, Martha; Ashby, Mark; Gillespie, Barbara S; Begelman, Susan M

    2010-12-01

    To evaluate the efficacy and safety of the thrombolytic tenecteplase, a fibrin-specific recombinant tissue plasminogen activator, for restoring function to dysfunctional central venous catheters (CVCs). In this double-blind, placebo-controlled study, eligible patients with dysfunctional nonhemodialysis CVCs were randomly assigned to two treatment arms. In the first arm (TNK-TNK-PBO), patients received an initial dose of intraluminal tenecteplase (TNK) (up to 2 mg), a second dose of tenecteplase if indicated, and a third placebo (PBO) dose. In the PBO-TNK-TNK arm, placebo was instilled first followed by up to two doses of tenecteplase, if needed, for restoration of catheter function. After administration of each dose, CVC function was assessed at 15, 30, and 120 minutes. There were 97 patients who received either TNK-TNK-PBO (n = 50) or PBO-TNK-TNK (n = 47). Within 120 minutes of initial study drug instillation, catheter function was restored to 30 patients (60%) in the TNK-TNK-PBO arm and 11 patients (23%) in the PBO-TNK-TNK arm, for a treatment difference of 37 percentage points (95% confidence interval 18-55; P = .0002). Cumulative restoration rates for CVC function increased to 87% after the second dose of tenecteplase in both study arms combined. Two patients developed a deep vein thrombosis (DVT) after exposure to tenecteplase; one DVT was considered to be drug related. No cases of intracranial hemorrhage, major bleeding, embolic events, catheter-related bloodstream infections, or catheter-related complications were reported. Tenecteplase was efficacious for restoration of catheter function in these study patients with dysfunctional CVCs. Copyright © 2010 SIR. Published by Elsevier Inc. All rights reserved.

  15. Safety of catheter-directed thrombolysis for the treatment of acute lower extremity deep vein thrombosis: A systematic review and meta-analysis.

    PubMed

    Wang, Li; Zhang, Chuanlin; Mu, Shaoyu; Yeh, Chao Hsing; Chen, Liqun; Zhang, Zeju; Wang, Xueqin

    2017-09-01

    Despite established guidelines, catheter-directed thrombolysis (CDT) for the management of acute lower extremity deep vein thrombosis (DVT) should not be overstated because the risks of CDT are uncertain. We performed a meta-analysis to comprehensively and quantitatively evaluate the safety of CDT for patients with acute lower extremity DVT. Relevant databases, including PubMed, Embase, Cochrane, Ovid MEDLINE, and Scopus, were searched up to January 2017. The inclusion criteria were applied to select patients with acute lower extremity DVT treated by CDT or compared CDT with anticoagulation. In case series studies, the pooled estimates of safety outcomes for complications, pulmonary embolism (PE), and mortality were calculated across studies. In studies comparing CDT with anticoagulation, summary odds ratios (ORs) were calculated. Of the 1696 citations identified, 24 studies (6 comparing CDT with anticoagulation and 18 case series) including 9157 patients met the eligibility criteria. In the case series studies, the pooled risks of major, minor, and total complications were 0.03 (95% confidence interval [CI]: 0.02-0.04), 0.07 (95% CI: 0.05-0.08), and 0.09 (95% CI: 0.08-0.11), respectively; other pooled risk results were 0.00 for PE (95% CI: 0.00-0.01) and 0.07 for mortality (95% CI: 0.03-0.11). Our meta-analysis of 6 studies comparing the risk of complications and PE related to CDT with those related to anticoagulation showed that CDT was associated with an increased risk of complications (OR = 4.36; 95% CI: 2.94-6.47) and PE (OR = 1.57; 95% CI: 1.37-1.79). Acute lower extremity DVT patients receiving CDT are associated with a low risk of complications. However, compared with anticoagulation, CDT is associated with a higher risk of complications and PE. Rare mortality related to thrombolytic therapy was reported. More evidence should be accumulated to prove the safety of CDT.

  16. Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

    PubMed

    Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E

    2013-01-01

    Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  17. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  18. Varicose vein - noninvasive treatment

    MedlinePlus

    Sclerotherapy; Laser therapy - varicose veins; Radiofrequency vein ablation; Endovenous thermal ablation; Ambulatory phlebectomy; Transilluminated power phlebotomy; Endovenous laser ablation; Varicose vein therapy

  19. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.

    PubMed

    Aryana, Arash; Singh, Sheldon M; Mugnai, Giacomo; de Asmundis, Carlo; Kowalski, Marcin; Pujara, Deep K; Cohen, Andrew I; Singh, Steve K; Fuenzalida, Charles E; Prager, Nelson; Bowers, Mark R; O'Neill, Padraig Gearoid; Brugada, Pedro; d'Avila, André; Chierchia, Gian-Battista

    2016-12-01

    Catheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities. In this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined. Of the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure. In this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.

  20. Reduction in Thrombosis and Bacterial Adhesion with 7 Day Implantation of S-Nitroso-N-acetylpenicillamine (SNAP)-Doped Elast-eon E2As Catheters in Sheep

    PubMed Central

    Brisbois, Elizabeth J.; Davis, Ryan P.; Jones, Anna M.; Major, Terry C.; Bartlett, Robert H.; Meyerhoff, Mark E.; Handa, Hitesh

    2015-01-01

    Thrombosis and infection are two common problems associated with blood-contacting medical devices such as catheters. Nitric oxide (NO) is known to be a potent antimicrobial agent as well as an inhibitor of platelet activation and adhesion. Healthy endothelial cells that line the inner walls of all blood vessels exhibit a NO flux of 0.5~4×10−10 mol cm−2 min−1 that helps prevent thrombosis. Materials with a NO flux that is equivalent to this level are expected to exhibit similar anti-thrombotic properties. In this study, NO-releasing catheters were fabricated by incorporating S-nitroso-N-acetylpenicillamine (SNAP) in the Elast-eon E2As polymer. The SNAP/E2As catheters release physiological levels of NO for up to 20 d, as measured by chemiluminescence. Furthermore, SNAP is stable in the E2As polymer, retaining 89% of the initial SNAP after ethylene oxide (EO) sterilization. The SNAP/E2As and E2As control catheters were implanted in sheep veins for 7 d to examine the effect on thrombosis and bacterial adhesion. The SNAP/E2As catheters reduced the thrombus area when compared to the control (1.56 ± 0.76 and 5.06 ± 1.44 cm2, respectively). A 90% reduction in bacterial adhesion was also observed for the SNAP/E2As catheters as compared to the controls. The results suggest that the SNAP/E2As polymer has the potential to improve the hemocompatibility and bactericidal activity of intravascular catheters, as well as other blood-contacting medical devices (e.g., vascular grafts, extracorporeal circuits). PMID:25685358

  1. Catheter-associated urinary tract infection.

    PubMed

    Tambyah, Paul A; Oon, Jolene

    2012-08-01

    Catheter-associated urinary tract infection (CAUTI) is the commonest nosocomial infection worldwide. Here we review the recent advances in the prevention of CAUTI. After more than 30 years, new guidelines were issued in 2008-2011 by the Infectious Diseases Society of America, Society for Healthcare Epidemiology of America, Healthcare Infection Control Practices Advisory Committee and European Association of Urology. These guidelines addressed novel technologies such as silver alloy or antimicrobial coatings on catheters, hydrophilic catheters, urethral stents, use of sealed catheter-tube junctions and antiinfective bladder irrigation. In addition, multiple trials have been published recently on the reduction of inappropriate urinary tract catheterization. Numerous strategies have been developed to reduce the incidence of CAUTI but few have proven effective. Reducing the inappropriate use of catheters and development of novel technologies targeted against these increasingly multidrug-resistant pathogens may be useful in the prevention of CAUTI in our vulnerable patients.

  2. Haemorrhoids are associated with internal iliac vein reflux in up to one-third of women presenting with varicose veins associated with pelvic vein reflux.

    PubMed

    Holdstock, J M; Dos Santos, S J; Harrison, C C; Price, B A; Whiteley, M S

    2015-03-01

    To determine the prevalence of haemorrhoids in women with pelvic vein reflux, identify which pelvic veins are associated with haemorrhoids and assess if extent of pelvic vein reflux influences the prevalence of haemorrhoids. Females presenting with leg varicose veins undergo duplex ultrasonography to assess all sources of venous reflux. Those with significant reflux arising from the pelvis are offered transvaginal duplex ultrasound (TVS) to evaluate reflux in the ovarian veins and internal Iliac veins and associated pelvic varices in the adnexa, vulvar/labial veins and haemorrhoids. Patterns and severity of reflux were evaluated. Between January 2010 and December 2012, 419 female patients with leg or vulvar varicose vein patterns arising from the pelvis underwent TVS. Haemorrhoids were identified on TVS via direct tributaries from the internal Iliac veins in 152/419 patients (36.3%) and absent in 267/419 (63.7%). The prevalence of the condition increased with the number of pelvic trunks involved. There is a strong association between haemorrhoids and internal Iliac vein reflux. Untreated reflux may be a cause of subsequent symptomatic haemorrhoids. Treatment with methods proven to work in conditions caused by pelvic vein incompetence, such as pelvic vein embolisation and foam sclerotherapy, could be considered. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Efficacy of catheter ablation of atrial fibrillation beyond HATCH score.

    PubMed

    Tang, Ri-Bo; Dong, Jian-Zeng; Long, De-Yong; Yu, Rong-Hui; Ning, Man; Jiang, Chen-Xi; Sang, Cai-Hua; Liu, Xiao-Hui; Ma, Chang-Sheng

    2012-10-01

    HATCH score is an established predictor of progression from paroxysmal to persistent atrial fibrillation (AF). The purpose of this study was to determine if HATCH score could predict recurrence after catheter ablation of AF. The data of 488 consecutive paroxysmal AF patients who underwent an index circumferential pulmonary veins (PV) ablation were retrospectively analyzed. Of these patients, 250 (51.2%) patients had HATCH score = 0, 185 (37.9%) patients had HATCH score = 1, and 53 (10.9%) patients had HATCH score ≥ 2 (28 patients had HATCH score = 2, 23 patients had HATCH score = 3, and 2 patients had HATCH score = 4). The patients with HATCH score ≥ 2 had significantly larger left atrium size, the largest left ventricular end systolic diameter, and the lowest ejection fraction. After a mean follow-up of (823 ± 532) days, the recurrence rates were 36.4%, 37.8% and 28.3% from the HATCH score = 0, HATCH score = 1 to HATCH score ≥ 2 categories (P = 0.498). Univariate analysis revealed that left atrium size, body mass index, and failure of PV isolation were predictors of AF recurrence. After adjustment for body mass index, left atrial size and PV isolation, the HATCH score was not an independent predictor of recurrence (HR = 0.92, 95% confidence interval = 0.76 - 1.12, P = 0.406) in multivariate analysis. HATCH score has no value in prediction of AF recurrence after catheter ablation.

  4. Is the treatment of the small saphenous veins with foam sclerotherapy at risk of deep vein thrombosis?

    PubMed

    Gillet, J L; Lausecker, M; Sica, M; Guedes, J M; Allaert, F A

    2014-10-01

    To assess the deep vein thrombosis risk of the treatment of the small saphenous veins depending on the anatomical pattern of the veins. A multicenter, prospective and controlled study was carried out in which small saphenous vein trunks were treated with ultrasound-guided foam sclerotherapy. The anatomical pattern (saphenopopliteal junction, perforators) was assessed by Duplex ultrasound before the treatment. All patients were systematically checked by Duplex ultrasound 8 to 30 days after the procedure to identify a potential deep vein thrombosis. Three hundred and thirty-one small saphenous veins were treated in 22 phlebology clinics. No proximal deep vein thrombosis occurred. Two (0.6%) medial gastrocnemius veins thrombosis occurred in symptomatic patients. Five medial gastrocnemius veins thrombosis and four cases of extension of the small saphenous vein sclerosis into the popliteal vein, which all occurred when the small saphenous vein connected directly into the popliteal vein, were identified by systematic Duplex ultrasound examination in asymptomatic patients. Medial gastrocnemius veins thrombosis were more frequent (p = 0.02) in patients with medial gastrocnemius veins perforator. A common outlet or channel between the small saphenous vein and the medial gastrocnemius veins did not increase the risk of deep vein thrombosis. Deep vein thrombosis after foam sclerotherapy of the small saphenous vein are very rare. Only 0.6% medial gastrocnemius veins thrombosis occurred in symptomatic patients. However, the anatomical pattern of the small saphenous vein should be taken into account and patients with medial gastrocnemius veins perforators and the small saphenous vein connected directly into the popliteal vein should be checked by Duplex ultrasound one or two weeks after the procedure. Recommendations based on our everyday practice and the findings of this study are suggested to prevent and treat deep vein thrombosis. © The Author(s) 2013 Reprints and

  5. Reduction of Thrombosis and Bacterial Infection via Controlled Nitric Oxide (NO) Release from S-Nitroso-N-acetylpenicillamine (SNAP) Impregnated CarboSil Intravascular Catheters

    PubMed Central

    2017-01-01

    Nitric oxide (NO) has many important physiological functions, including its ability to inhibit platelet activation and serve as potent antimicrobial agent. The multiple roles of NO in vivo have led to great interest in the development of biomaterials that can deliver NO for specific biomedical applications. Herein, we report a simple solvent impregnation technique to incorporate a nontoxic NO donor, S-nitroso-N-acetylpenicillamine (SNAP), into a more biocompatible biomedical grade polymer, CarboSil 20 80A. The resulting polymer-crystal composite material yields a very stable, long-term NO release biomaterial. The SNAP impregnation process is carefully characterized and optimized, and it is shown that SNAP crystal formation occurs in the bulk of the polymer after solvent evaporation. LC-MS results demonstrate that more than 70% of NO release from this new composite material originates from the SNAP embedded CarboSil phase, and not from the SNAP species leaching out into the soaking solution. Catheters prepared with CarboSil and then impregnated with 15 wt % SNAP provide a controlled NO release over a 14 d period at physiologically relevant fluxes and are shown to significantly reduce long-term (14 day) bacterial biofilm formation against Staphylococcus epidermidis and Pseudonomas aeruginosa in a CDC bioreactor model. After 7 h of catheter implantation in the jugular veins of rabbit, the SNAP CarboSil catheters exhibit a 96% reduction in thrombus area (0.03 ± 0.01 cm2/catheter) compared to the controls (0.84 ± 0.19 cm2/catheter) (n = 3). These results suggest that SNAP impregnated CarboSil can become an attractive new biomaterial for use in preparing intravascular catheters and other implanted medical devices. PMID:28317023

  6. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  7. Rapid guiding catheter swapping for management of rupture during percutaneous venoplasty for idiopathic occlusion of superior vena cava.

    PubMed

    Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay

    2015-04-01

    Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.

  8. Predisposing factors to phlebitis in patients with peripheral intravenous catheters: a descriptive study.

    PubMed

    Uslusoy, Esin; Mete, Samiye

    2008-04-01

    The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.

  9. Fast Track ultrasound protocol to detect acute complications after totally implantable venous access device placement.

    PubMed

    Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng

    2015-01-01

    The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.

  10. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    PubMed Central

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.

    2014-01-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802

  11. Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation.

    PubMed

    Malcolme-Lawes, Louisa C; Lim, Phang Boon; Koa-Wing, Michael; Whinnett, Zachary I; Jamil-Copley, Shahnaz; Hayat, Sajad; Francis, Darrel P; Kojodjojo, Pipin; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2013-01-01

    Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on

  12. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  13. Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.

    PubMed

    Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan

    2013-01-01

    Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.

  14. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    PubMed

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  15. Serratia marcescens bacteraemia outbreak in haemodialysis patients with tunnelled catheters due to colonisation of antiseptic solution. Experience at 4 hospitals.

    PubMed

    Merino, José L; Bouarich, Hanane; Pita, Mª José; Martínez, Patricia; Bueno, Blanca; Caldés, Silvia; Corchete, Elena; Jaldo, Mª Teresa; Espejo, Beatriz; Paraíso, Vicente

    The application of antiseptic solution for handling tunnelled catheters is recommended in patients undergoing haemodialysis. These routine antiseptic procedures in handling catheters are crucial to avoid complications. We report an outbreak of Serratia marcescens (S. marcescens) bacteraemia in numerous haemodialysis units of the Community of Madrid. The first cases of bacteraemia due to S. marcescens were isolated in December 2014. The Preventive Medicine Services were informed of the detection of an atypical pathogen in several patients, suspecting a probable nosocomial outbreak. Information from 4 centres with similar S. marcescens bacteraemia was analysed. Twenty-one cases of bacteraemia related to S. marcescens were identified. The mean age of affected patients was 72±10 years. The mean time on haemodialysis of affected patients was 33±13 months (range: 3-83 months), the median time of tunnelled catheter was 22±13 months. In 11 cases the clinical picture was similar, with hypotension and general malaise during the haemodialysis session. Fever was present in a further 7 cases. In 3 cases the presentation was asymptomatic and was detected by blood cultures. All patients had tunnelled catheters (12 patients with catheter in the right jugular vein, 5 in the left jugular, 2 in the right femoral artery and 2 in the left subclavian artery). Gentamicin intravenous doses (1mg/kg) with catheter lock solution with ciprofloxacin post-dialysis were administered for 3 weeks in 6 patients. In 12 patients the treatment was ceftazidime (2g IV) plus catheter lock solution with the same antibiotic, for 2 weeks. Four patients received oral ciprofloxacin for 2 weeks, in one case together with IV vancomycin. The patients were asymptomatic and without new episodes 48hours after the treatment. No major complications were observed. The teams informed the health authorities of the situation, which then reported the presence of batches of antiseptic (chlorhexidine 0.05 and 2

  16. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  17. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  18. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  19. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  20. Extrahepatic portal vein obstruction and portal vein thrombosis in special situations: Need for a new classification.

    PubMed

    Wani, Zeeshan A; Bhat, Riyaz A; Bhadoria, Ajeet S; Maiwall, Rakhi

    2015-01-01

    Extrahepatic portal vein obstruction is a vascular disorder of liver, which results in obstruction and cavernomatous transformation of portal vein with or without the involvement of intrahepatic portal vein, splenic vein, or superior mesenteric vein. Portal vein obstruction due to chronic liver disease, neoplasm, or postsurgery is a separate entity and is not the same as extrahepatic portal vein obstruction. Patients with extrahepatic portal vein obstruction are generally young and belong mostly to Asian countries. It is therefore very important to define portal vein thrombosis as acute or chronic from management point of view. Portal vein thrombosis in certain situations such as liver transplant and postsurgical/liver transplant period is an evolving area and needs extensive research. There is a need for a new classification, which includes all areas of the entity. In the current review, the most recent literature of extrahepatic portal vein obstruction is reviewed and summarized.

  1. Extrahepatic Portal Vein Obstruction and Portal Vein Thrombosis in Special Situations: Need for a New Classification

    PubMed Central

    Wani, Zeeshan A.; Bhat, Riyaz A.; Bhadoria, Ajeet S.; Maiwall, Rakhi

    2015-01-01

    Extrahepatic portal vein obstruction is a vascular disorder of liver, which results in obstruction and cavernomatous transformation of portal vein with or without the involvement of intrahepatic portal vein, splenic vein, or superior mesenteric vein. Portal vein obstruction due to chronic liver disease, neoplasm, or postsurgery is a separate entity and is not the same as extrahepatic portal vein obstruction. Patients with extrahepatic portal vein obstruction are generally young and belong mostly to Asian countries. It is therefore very important to define portal vein thrombosis as acute or chronic from management point of view. Portal vein thrombosis in certain situations such as liver transplant and postsurgical/liver transplant period is an evolving area and needs extensive research. There is a need for a new classification, which includes all areas of the entity. In the current review, the most recent literature of extrahepatic portal vein obstruction is reviewed and summarized. PMID:26021771

  2. Anti-fouling strategies for central venous catheters

    PubMed Central

    Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-01-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528

  3. Anti-fouling strategies for central venous catheters.

    PubMed

    Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-12-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.

  4. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    PubMed

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  5. Outcomes after peritoneal dialysis catheter placement.

    PubMed

    Carpenter, Jennifer L; Fallon, Sara C; Swartz, Sarah J; Minifee, Paul K; Cass, Darrell L; Nuchtern, Jed G; Pimpalwar, Ashwin P; Brandt, Mary L

    2016-05-01

    The purpose of this study was to review surgical outcomes after elective placement of peritoneal dialysis (PD) catheters in children with end-stage renal disease. Children with PD catheters placed between February 2002 and July 2014 were retrospectively reviewed. Outcomes were catheter life, late (>30days post-op) complications (catheter malfunction, catheter malposition, infection), and re-operation rates. Comparison groups included laparoscopic versus open placement, age<2, and weight<10kg. Univariate and multivariate analysis were performed. One hundred sixteen patients had 173 catheters placed (122 open, 51 laparoscopic) with an average patient age of 9.7±6.3years. Mean catheter life was similar in the laparoscopic and open groups (581±539days versus 574±487days, p=0.938). The late complication rate was higher for open procedures (57% versus 37%, p=0.013). Children age<2 or weight<10kg had higher re-operation rates (64% versus 42%, p=0.014 and 73% versus 40%, p=0.001, respectively). Adjusted for age and weight, open technique remained a risk factor for late complications (OR 2.44, 95% CI 1.20-4.95) but not re-operation. Laparoscopic placement appears to reduce the rate of late complications in children who require PD dialysis catheters. Children <2years age or <10kg remain at risk for complications regardless of technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine

    PubMed Central

    van Duin, Richard W B; Verzijl, Annemarie; Reiss, Irwin K; Duncker, Dirk J; Merkus, Daphne

    2016-01-01

    This protocol describes the surgical procedure to chronically instrument swine and the procedure to exercise swine on a motor-driven treadmill. Early cardiopulmonary dysfunction is difficult to diagnose, particularly in animal models, as cardiopulmonary function is often measured invasively, requiring anesthesia. As many anesthetic agents are cardiodepressive, subtle changes in cardiovascular function may be masked. In contrast, chronic instrumentation allows for measurement of cardiopulmonary function in the awake state, so that measurements can be obtained under quiet resting conditions, without the effects of anesthesia and acute surgical trauma. Furthermore, when animals are properly trained, measurements can also be obtained during graded treadmill exercise. Flow probes are placed around the aorta or pulmonary artery for measurement of cardiac output and around the left anterior descending coronary artery for measurement of coronary blood flow. Fluid-filled catheters are implanted in the aorta, pulmonary artery, left atrium, left ventricle and right ventricle for pressure measurement and blood sampling. In addition, a 20 G catheter is positioned in the anterior interventricular vein to allow coronary venous blood sampling. After a week of recovery, swine are placed on a motor-driven treadmill, the catheters are connected to pressure and flow meters, and swine are subjected to a five-stage progressive exercise protocol, with each stage lasting 3 min. Hemodynamic signals are continuously recorded and blood samples are taken during the last 30 sec of each exercise stage. The major advantage of studying chronically instrumented animals is that it allows serial assessment of cardiopulmonary function, not only at rest but also during physical stress such as exercise. Moreover, cardiopulmonary function can be assessed repeatedly during disease development and during chronic treatment, thereby increasing statistical power and hence limiting the number of animals

  7. Advanced Imaging Catheter: Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body

  8. Role of Catheter-directed Thrombolysis in Management of Iliofemoral Deep Venous Thrombosis.

    PubMed

    Chen, James X; Sudheendra, Deepak; Stavropoulos, S William; Nadolski, Gregory J

    2016-01-01

    The treatment for iliofemoral deep venous thrombosis (DVT) is challenging, as the use of anticoagulation alone can be insufficient for restoring venous patency and thus lead to prolongation of acute symptoms and an increased risk of chronic complications, including venous insufficiency and postthrombotic syndrome (PTS). In these cases, earlier and more complete thrombus removal can ameliorate acute symptoms and reduce long-term sequelae. Endovascular therapies involving the use of pharmacologic, mechanical, and combined pharmacomechanical modalities have been developed to achieve these goals. The most frequently used of these techniques, catheter-directed thrombolysis (CDT), involves the infusion of a thrombolytic agent through a multiple-side-hole catheter placed within the thrombosed vein to achieve high local doses and thereby break down the clot while minimizing systemic thrombolytic agent exposure. Randomized controlled trial results have indicated decreased PTS rates and improved venous patency rates in patients treated with CDT compared with these rates in patients treated with anticoagulation. The use of newer pharmacomechanical techniques, as compared with conventional CDT, reduces procedural times and thrombolytic agent doses and is the subject of ongoing investigations. Endovascular thrombus removal techniques offer a means to improve venous valvular function and decrease the risk of debilitating long-term complications such as PTS and are a promising option for treating patients with iliofemoral DVT. (©)RSNA, 2016.

  9. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  10. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  11. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  12. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  13. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  14. Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.

    PubMed

    Sunaga, Akihiro; Masuda, Masaharu; Asai, Mitsutoshi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Syota; Mano, Toshiaki

    2018-04-10

    Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media. Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation. We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%. Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.

  15. Prevention of catheter-associated urinary tract infection

    PubMed Central

    Trautner, Barbara W.; Hull, Richard A.; Darouiche, Rabih O.

    2010-01-01

    Purpose of review The underlying cause of catheter-associated urinary tract infection is biofilm formation by uropathogens on the urinary catheter. Biofilm is a relatively new concept in medicine, and current measures to prevent biofilm formation are inadequate. Considerable work is being done in this area, but little clinical progress has been made. The purpose of this review is to analyze recent publications concerning prevention of catheter-associated urinary tract infection. Recent findings Several recent studies have elucidated aspects of biofilm formation in catheter-associated urinary tract infection. Other researchers are working on methods to disrupt biofilm formation on catheter surfaces. At the same time, the magnitude of the problem of catheter-associated urinary tract infection has increased awareness of the effectiveness of basic infection control measures. A modern approach to infection control may include computerized ordering systems that minimize unnecessary days of catheterization. Finally, consumption of cranberry juice products and bacterial interference are two novel approaches to urinary tract infection prevention. Summary Biofilm-disrupting strategies offer promise for the future but have little immediate applicability. Implementation of infection control measures to improve catheter function and remove unnecessary catheters can be done at the present time. In general, prevention of catheter-associated urinary tract infection remains an elusive goal. More basic research at the level of pathogenesis is needed so that novel strategies can be designed. PMID:15647698

  16. Cavernous Transformation of Portal Vein Secondary to Portal Vein Thrombosis: A Case Report

    PubMed Central

    Ramos, Radhames; Park, Yoojin; Shazad, Ghulamullah; A.Garcia, Christine; Cohen, Ronny

    2012-01-01

    There are few reported cases of cavernous transformation of the portal vein (CTPV) in adults. We present a case of a 58 year-old male who was found to have this complication due to portal vein thrombosis (PVT). A 58-year old African American male with chronic alcohol and tobacco use presented with a 25-day history of weakness, generalized malaise, nausea and vomiting associated with progressively worsening anorexia and weight loss. The patient was admitted for severe anemia in conjunction with abnormal liver function tests and electrolyte abnormalities, and to rule out end stage liver disease or hepatic malignancy. The work-up for anemia showed no significant colon abnormalities, cholecystitis, liver cirrhosis, or liver abnormalities but could not rule out malignancy. An esophageogastroduodenoscopy (EGD) was suspicious for a mass compressing the stomach and small bowel. After further work-up, the hepatic mass has been diagnosed as a cavernous transformation of the portal vein (CTPV), a very rare complication of portal vein thrombosis (PVT). Cavernous Transformation of the Portal Vein (CTPV) is a rare and incurable complication of portal vein thrombosis (PVT) that should be considered as one of the differential diagnoses of a hepatic mass. Keywords Cavernous transformation of the portal vein; Portal vein thrombosis; Portal hypertension; Hyperbilirubinemia; Hepatic mass PMID:22383935

  17. FAQs about Catheter-Associated Urinary Tract Infection

    MedlinePlus

    ... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...

  18. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  19. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  20. Hepatic venous outflow obstruction after living donor liver transplantation managed with ectopic placement of a foley catheter: A case report

    PubMed Central

    Wahab, Mohamed Abdel; Shehta, Ahmed; Hamed, Hosam; Elshobary, Mohamed; Salah, Tarek; Sultan, Ahmed Mohamed; Fathy, Omar; Elghawalby, Ahmed; Yassen, Amr; Shiha, Usama

    2015-01-01

    Introduction The early hepatic venous outflow obstruction (HVOO) is a rare but serious complication after liver transplantation, which may result in graft loss. We report a case of early HVOO after living donor liver transplantation, which was managed by ectopic placement of foley catheter. Presentation A 51 years old male patient with end stage liver disease received a right hemi-liver graft. On the first postoperative day the patient developed impairment of the liver functions. Doppler ultrasound (US) showed absence of blood flow in the right hepatic vein without thrombosis. The decision was to re-explore the patient, which showed torsion of the graft upward and to the right side causing HVOO. This was managed by ectopic placement of a foley catheter between the graft and the diaphragm and the chest wall. Gradual deflation of the catheter was gradually done guided by Doppler US and the patient was discharged without complications. Discussion Mechanical HVOO results from kinking or twisting of the venous anastomosis due to anatomical mismatch between the graft and the recipient abdomen. It should be managed surgically by repositioning of the graft or redo of venous anastomosis. Several ideas had been suggested for repositioning and fixation of the graft by the use of Sengstaken–Blakemore tubes, tissue expanders, and surgical glove expander. Conclusion We report the use of foley catheter to temporary fix the graft and correct the HVOO. It is a simple and safe way, and could be easily monitored and removed under Doppler US without any complications. PMID:25805611

  1. Real-time rotational ICE imaging of the relationship of the ablation catheter tip and the esophagus during atrial fibrillation ablation.

    PubMed

    Helms, Adam; West, J Jason; Patel, Amit; Mounsey, J Paul; DiMarco, John P; Mangrum, J Michael; Ferguson, John D

    2009-02-01

    Atrioesophageal fistula is a rare complication of atrial fibrillation (AF) ablation that should be avoided. We investigated whether rotational intracardiac echocardiography (ICE) can help to minimize ablation close to the esophagus. We studied 41 patients referred for catheter ablation of refractory AF. A rotational ICE catheter was inserted into the (LA) to determine the location of the esophagus. The esophagus was identified to be either adjacent to the pulmonary vein (PV) ostium or to a cuff 2 cm outside the ostium. Circumferential ablation was performed at the PV ostium, with the exact ablation location determined by ICE. The relationship of the catheter tip to the esophagus was imaged during energy delivery, allowing interruption when respiration moved the tip closer to the esophagus. Out of 41 patients, the esophagus was seen near left-sided PVs in 32 and near right-sided PVs in three patients. The median distance from LA endocardium to esophagus was 2.2 mm (range, 1.4-6 mm). In 21 of 35 patients with a closely related esophagus, ablation over the esophagus was avoided by ablating either lateral or medial to the esophagus. In 14 patients, the esophagus could not be avoided, and risk was minimized by limiting lesion size. Significant movement (>10 mm) of the esophagus during the procedure occurred in 3/41 cases. Rotational ICE can accurately determine the distance of ablation sites from the esophagus. Real-time imaging of the relationship of the ablation catheter tip to the esophagus may reduce the incidence of esophageal injury.

  2. Guidelines of the First International Consensus Conference on Endovenous Thermal Ablation for Varicose Vein Disease--ETAV Consensus Meeting 2012.

    PubMed

    Pavlović, Miloš D; Schuller-Petrović, Sanja; Pichot, Olivier; Rabe, Eberhard; Maurins, Uldis; Morrison, Nick; Pannier, Felizitas

    2015-05-01

    Endovenous thermal ablation (ETA) procedures are catheter-directed, ultrasound (US)-guided thermal methods for treatment in varicose veins disease. Radiofrequency, laser or steam energy thermally denatures vein wall collagen, leading first to vein wall inflammation, then fibrosis and finally to occlusion. The aim of this guideline is to give evidence-based recommendations for ETA procedures. These guidelines were drafted during a consensus meeting of a group of experts in the field of ETA in June 2012 (Hvar, Croatia) under the auspices of the International Union of Phlebology (IUP). These guidelines review the present state of knowledge as reflected in peer-reviewed published medical literature. The recommendations of these guidelines are graded according to the American College of Chest Physicians Task Force recommendations on Grading Strength of Recommendations and Quality of Evidence in Clinical Guidelines. Recommendations on the use of ETA procedures were made based on the quality of evidence for efficacy, safety, tolerability, cosmetic outcome, patient satisfaction/preference and, where appropriate, on the experts' opinion. Health economics were not considered, since differences in national health systems and pricing make it difficult to form general conclusions that are relevant at an international level. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. [Peripheral intravenous catheter-related phlebitis].

    PubMed

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  4. Effects of albendazole nanoparticles in mice with hepatic echinococosis: Portal vein cannulation versus intravenous administration.

    PubMed

    Zhu, Di-Wen; Zhang, Ming-Xing; Bao, Ying-Jun; Gu, Jun-Peng; Ji, Wei-Zheng; Zhang, Hai-Xiao; Ren, Wei-Xin

    2015-07-01

    To compare the ABZ and its metabolites concentration in cyst tissue of hepatic alveolar echinococcosis administered by different routes, forty male Wistar rats receiving albendazole nanoparticles from tail vein and portal vein were divided into two groups, the concentration of ABZ and its metabolites ABZSO, ABZSO2, in the cyst tissue, were analyzed by HPLC at 2, 4, 8, 24, 36 h after administration. The parent drug and its metabolites were detected in plasm and the cyst tissue after portal cannulation and intravenous administration. The last results were the concentration of ABZ in the portal cannulation group was higher than in the intravenous group at every time point (p < 0.05). Compared to the intravenous group, the portal cannulation administration of ABZ led to a lower plasm concentration of ABZ. The concentration of ABZ and the active ABZSO were significantly higher in the portal cannulation group than that of the intravenous group. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Safety and Efficacy of Catheter Direct Thrombolysis in Management of Acute Iliofemoral Deep Vein Thrombosis: A Systematic Review.

    PubMed

    Elbasty, Ahmed; Metcalf, James

    2017-12-01

    Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration's tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured.

  6. Transoesophageal echocardiographic evaluation of central venous catheter positioning using Peres' formula or a radiological landmark-based approach: a prospective randomized single-centre study.

    PubMed

    Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P

    2017-02-01

    The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  8. Transverse closure of mesenterico-portal vein after vein resection in pancreatoduodenectomy.

    PubMed

    Chua, T C; de Reuver, P R; Staerkle, R F; Neale, M L; Arena, J; Mittal, A; Shanbhag, S T; Gill, A J; Samra, J S

    2016-02-01

    Resection of the involved mesenteric-portal vein (MPV) is increasingly performed in pancreatoduodenectomy. The primary aim of this study is to assess the rate of R0 resection in transverse closure (TC) versus segmental resection with end-to-end (EE) closure and the secondary aims are to assess the short-term morbidity and long-term survival of TC versus EE. Patients undergoing pancreatoduodenectomy with MPV resection were identified from a prospectively database. The reconstruction technique were examined and categorized. Clinical, pathological, short-term and long-term survival outcomes were compared between groups. 110 patients underwent PD with MPV resection of which reconstruction was performed with an end-to-end technique in 92 patients (84%) and transverse closure technique in 18 patients (16%). Patients undergoing transverse closure tended to have had a shorter segment of vein resected (≤2 cm) compared to the end-to-end (83% vs. 43%; P = 0.004) with no difference in R0 rate. Short-term morbidity was similar. The median and 5-year survival was 30.0 months and 18% respectively for patients undergoing transverse closure and 28.6 months and 7% respectively for patients undergoing end-to-end reconstruction (P = 0.766). Without compromising the R0 rate, transverse closure to reconstruct the mesenteric-portal vein is shown to be feasible and safe in the setting when a short segment of vein resection is required during pancreatoduodenectomy. Synopsis - We describe a vein closure technique, transverse closure, which avoids the need for a graft, or re-implantation of the splenic vein when resection of the mesenteric-portal vein confluence is required during pancreatoduodenectomy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  10. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  11. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  12. S-Nitroso-N-acetylpenicillamine (SNAP) Impregnated Silicone Foley Catheters: A Potential Biomaterial/Device To Prevent Catheter-Associated Urinary Tract Infections

    PubMed Central

    2016-01-01

    Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294

  13. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    PubMed

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P < 0.001). Venous pressure waveforms were obtained in all patients and attenuation of the waveform was always observed prior to onset of phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  14. Vein matching using artificial neural network in vein authentication systems

    NASA Astrophysics Data System (ADS)

    Noori Hoshyar, Azadeh; Sulaiman, Riza

    2011-10-01

    Personal identification technology as security systems is developing rapidly. Traditional authentication modes like key; password; card are not safe enough because they could be stolen or easily forgotten. Biometric as developed technology has been applied to a wide range of systems. According to different researchers, vein biometric is a good candidate among other biometric traits such as fingerprint, hand geometry, voice, DNA and etc for authentication systems. Vein authentication systems can be designed by different methodologies. All the methodologies consist of matching stage which is too important for final verification of the system. Neural Network is an effective methodology for matching and recognizing individuals in authentication systems. Therefore, this paper explains and implements the Neural Network methodology for finger vein authentication system. Neural Network is trained in Matlab to match the vein features of authentication system. The Network simulation shows the quality of matching as 95% which is a good performance for authentication system matching.

  15. Is traditional reading of the bedside chest radiograph appropriate to detect intraatrial central venous catheter position?

    PubMed

    Wirsing, Melanie; Schummer, Claudia; Neumann, Rotraud; Steenbeck, Jörg; Schmidt, Peter; Schummer, Wolfram

    2008-09-01

    Traditionally, the positioning of central venous catheters (CVCs) outside the right atrium (RA) in patients receiving intensive care is determined by surrogate landmarks on bedside chest radiographs (CXRs). The validity of this method was examined by comparing readings of radiologists with the results of transesophageal echocardiography (TEE). Prospective study at university hospital. Two hundred thirteen adults scheduled for cardiothoracic surgery were randomized to right or left internal jugular vein catheterization under ECG guidance. One senior radiologist and two radiologists in training independently read the CXRs, and determined whether the CVC tip ended in the RA and measured the vertical distance from the CVC tip to the carina (TC-distance). Two hundred twelve CVC tips could be identified by TEE. Only left-sided CVCs (n = 5) ended in the upper RA (2.4%). Three of those patients were shorter than 160 cm. Specificity was 94% for senior radiologist, 44% for the first radiologist in training, and 60% for the second radiologist in training. The TC-distance of intraatrial catheters was 39, 55, 59, 80, and 83 mm, respectively. Thus, a TC-distance < or = 55 mm ensured extraatrial tip position in four of five intraatrial CVCs (80%, p = 0.002). The TC-distance of extraatrial catheters ranged from - 26 to 102 mm. Reading of a bedside CXR alone is not very accurate to identify intraatrial CVC tip position. TC-distance is a helpful marker, and its specificity is as good as that of an experienced radiologist if a cutoff value of 55 mm is chosen.

  16. Early removal of urethral catheter with suprapubic tube drainage versus urethral catheter drainage alone after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P

    2014-07-01

    Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. The dangers of long-term catheter drainage.

    PubMed

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  18. Risk Factors of Catheter-Related Thrombosis (CRT) in Cancer Patients: A Patient-Level Data (IPD) Meta-Analysis of Clinical Trials and Prospective Studies

    PubMed Central

    Saber, W.; Moua, T.; Williams, E. C.; Verso, M.; Agnelli, G.; Couban, S.; Young, A.; De Cicco, M.; Biffi, R.; van Rooden, C. J.; Huisman, M. V.; Fagnani, D.; Cimminiello, C.; Moia, M.; Magagnoli, M.; Povoski, S. P.; Malak, S. F.; Lee, A. Y.

    2010-01-01

    Background Knowledge of independent, baseline risk factors of catheter-related thrombosis (CRT) may help select adult cancer patients at high risk to receive thromboprophylaxis. Objectives We conducted a meta-analysis of individual patient-level data to identify these baseline risk factors. Patients/Methods MEDLINE, EMBASE, CINAHL, CENTRAL, DARE, Grey literature databases were searched in all languages from 1995-2008. Prospective studies and randomized controlled trials (RCTs) were eligible. Studies were included if original patient-level data were provided by the investigators and if CRT was objectively confirmed with valid imaging. Multivariate logistic regression analysis of 17 prespecified baseline characteristics was conducted. Adjusted odds ratios (OR) and 95% confidence intervals (CI) were estimated. Results A total sample of 5636 subjects from 5 RCTs and 7 prospective studies was included in the analysis. Among these subjects, 425 CRT events were observed. In multivariate logistic regression, the use of implanted ports as compared with peripherally implanted central venous catheters (PICC), decreased CRT risk (OR = 0.43; 95% CI, 0.23-0.80), whereas past history of deep vein thrombosis (DVT) (OR = 2.03; 95% CI, 1.05-3.92), subclavian venipuncture insertion technique (OR = 2.16; 95% CI, 1.07-4.34), and improper catheter tip location (OR = 1.92; 95% CI, 1.22-3.02), increased CRT risk. Conclusions CRT risk is increased with using PICC catheters, previous history of DVT, subclavian venipuncture insertion technique and improper positioning of the catheter tip. These factors may be useful for risk stratifying patients to select those for thromboprophylaxis. Prospective studies are needed to validate these findings. PMID:21040443

  19. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  20. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.

    PubMed

    Stensballe, J; Looms, D; Nielsen, P N; Tvede, M

    2005-12-01

    To compare two hydrophilic-coated (SpeediCath and LoFric and one uncoated gel-lubricated catheter (InCare Advance Plus) concerning withdrawal friction force and urethral micro trauma. 49 healthy male volunteers participated in this prospective, randomised, blinded, crossover study of three different bladder catheters. The withdrawal friction force was measured, and urine analysis of blood, nitrite and leucocytes, microbiological analysis of urine cultures and subjective evaluation of the catheters were performed. 40 participants completed the study and were included in the analysis. SpeediCath exerted a significantly lower mean withdrawal friction force and work than the gel-lubricated uncoated catheter, whereas LoFric exerted a significantly higher mean friction force than both of the other catheters. The hydrophilic catheters caused less microscopic haematuria and less pain than the gel-lubricated uncoated catheter. Furthermore, 93% of the participants preferred the hydrophilic catheters. Hydrophilic-coated catheters perform better than uncoated catheters with regard to haematuria and preference. SpeediCath, but not LoFric, exerts less withdrawal friction force than InCare Advance Plus.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minko, P., E-mail: peterminko@yahoo.com; Bücker, A.; Laschke, M.

    PurposeTo investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model.Materials and MethodsIliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performedmore » to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination.ResultsThrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters.ConclusionThe Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.« less

  2. Evaluation of the pharmacokinetics of imipenem following regional limb perfusion using the saphenous and the cephalic veins in standing horses.

    PubMed

    Kelmer, G; Tatz, A J; Kdoshim, E; Britzi, M; Segev, G

    2017-10-01

    This prospective experimental study goal was to determine the pharmacokinetics of imipenem after intravenous regional limb perfusion (IV-RLP) in standing horses. Nine horses participated in the study; that was approved by the University Animal Care and Use Committee. One thoracic limb or one pelvic limb of each horse was randomly selected. After the veins were catheterized, an Esmarch bandage tourniquet was applied and the catheter was injected with a solution containing 500mg of imipenem. Synovial fluid samples were collected from the fetlock joint and blood samples were collected from the jugular vein. All samples were analyzed for imipenem concentration using liquid chromatography mass spectrometry. Cmax of imipenem in the fetlock joint using the cephalic and the saphenous vein was 87 and 60μg⁄mL, respectively. The results indicate that by performing IV-RLP using the cephalic/saphenous, one can achieve imipenem concentrations in the fetlock joint that are well above the MIC of most susceptible pathogens including resistant bacteria such as Methicillin Resistant Staphylococcus aureus (MRSA) and Pseudomonas aeruginosa. Thus, with selective; judicious use, RLP with imipenem can markedly increase treatment efficacy of severe distal limb infections in horses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    PubMed

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  4. Study Comparing Vein Integrity and Clinical Outcomes in Open Vein Harvesting and 2 Types of Endoscopic Vein Harvesting for Coronary Artery Bypass Grafting: The VICO Randomized Clinical Trial (Vein Integrity and Clinical Outcomes)

    PubMed Central

    Krishnamoorthy, Bhuvaneswari; Critchley, William R.; Thompson, Alexander J.; Payne, Katherine; Morris, Julie; Venkateswaran, Rajamiyer V.; Caress, Ann L.

    2018-01-01

    Background Current consensus statements maintain that endoscopic vein harvesting (EVH) should be standard care in coronary artery bypass graft surgery, but vein quality and clinical outcomes have been questioned. The VICO trial (Vein Integrity and Clinical Outcomes) was designed to assess the impact of different vein harvesting methods on vessel damage and whether this contributes to clinical outcomes after coronary artery bypass grafting. Methods In this single-center, randomized clinical trial, patients undergoing coronary artery bypass grafting with an internal mammary artery and with 1 to 4 vein grafts were recruited. All veins were harvested by a single experienced practitioner. We randomly allocated 300 patients into closed tunnel CO2 EVH (n=100), open tunnel CO2 EVH (n=100), and traditional open vein harvesting (n=100) groups. The primary end point was endothelial integrity and muscular damage of the harvested vein. Secondary end points included clinical outcomes (major adverse cardiac events), use of healthcare resources, and impact on health status (quality-adjusted life-years). Results The open vein harvesting group demonstrated marginally better endothelial integrity in random samples (85% versus 88% versus 93% for closed tunnel EVH, open tunnel EVH, and open vein harvesting; P<0.001). Closed tunnel EVH displayed the lowest longitudinal hypertrophy (1% versus 13.5% versus 3%; P=0.001). However, no differences in endothelial stretching were observed between groups (37% versus 37% versus 31%; P=0.62). Secondary clinical outcomes demonstrated no significant differences in composite major adverse cardiac event scores at each time point up to 48 months. The quality-adjusted life-year gain per patient was 0.11 (P<0.001) for closed tunnel EVH and 0.07 (P=0.003) for open tunnel EVH compared with open vein harvesting. The likelihood of being cost-effective, at a predefined threshold of £20 000 per quality-adjusted life-year gained, was 75% for closed tunnel EVH

  5. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schellhammer, Frank, E-mail: frank.schellhammer@med.uni-duesseldorf.d; Esch, Jan Schulte am; Hammerschlag, Sascha

    2008-07-15

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  6. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  7. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  10. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  11. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  12. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  13. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    PubMed

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  14. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    PubMed Central

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-01-01

    ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. PMID:27508916

  15. Near-tail reconnection as the cause of cometary tail disconnections

    NASA Technical Reports Server (NTRS)

    Russell, C. T.; Saunders, M. A.; Phillips, J. L.; Fedder, J. A.

    1986-01-01

    In a cometary tail disconnection event the plasma tail appears to separate from the coma and to accelerate away from it. As this occurs a new tail begins to form. It is proposed that these disconnections arise in a manner analogous to geomagnetic substorms, i.e., by the formation of a strongly reconnecting region in the near tail that forms a magnetic island in the coma and ejects the plasma tail by strengthening the magnetic 'slingshot' within the tail. This reconnection process may be triggered by several different processes, such as interplanetary shocks or variations in the Alfven Mach number.

  16. Safety and Efficacy of Catheter Direct Thrombolysis in Management of Acute Iliofemoral Deep Vein Thrombosis: A Systematic Review

    PubMed Central

    Elbasty, Ahmed; Metcalf, James

    2017-01-01

    Purpose Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. Materials and Methods MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration’s tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Results Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. Conclusion CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured. PMID:29354622

  17. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    PubMed

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  18. Development of Bend Sensor for Catheter Tip

    NASA Astrophysics Data System (ADS)

    Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo

    Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.

  19. A novel, inexpensive, double lumen suprapubic catheter for urodynamics.

    PubMed

    Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G

    2004-03-01

    We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.

  20. Routine Chest Radiographs After Central Line Insertion: Mandatory Postprocedural Evaluation or Unnecessary Waste of Resources?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucey, Brian; Varghese, Jose C.; Haslam, Philip

    1999-09-15

    Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less

  1. Thermal Windows on Brazilian Free-tailed Bats Facilitate Thermoregulation during Prolonged Flight

    PubMed Central

    Reichard, Jonathan D.; Prajapati, Suresh I.; Austad, Steven N.; Keller, Charles; Kunz, Thomas H.

    2010-01-01

    The Brazilian free-tailed bat (Tadarida brasiliensis) experiences challenging thermal conditions while roosting in hot caves, flying during warm daylight conditions, and foraging at cool high altitudes. Using thermal infrared cameras, we identified hot spots along the flanks of free-ranging Brazilian free-tailed bats, ventral to the extended wings. These hot spots are absent in syntopic cave myotis (Myotis velifer), a species that forages over relatively short distances, and does not engage in long-distance migration. We hypothesized that the hot spots, or “radiators,” on Brazilian free-tailed bats may be adaptations for migration, particularly in this long-distance, high-flying species. We examined the vasculature of radiators on Brazilian free-tailed bats with transillumination to characterize the unique arrangements of arteries and veins that are positioned perpendicular to the body in the proximal region of the wing. We hypothesized that these radiators aid in maintaining heat balance by flushing the uninsulated thermal window with warm blood, thereby dissipating heat while bats are flying under warm conditions, but shunting blood away and conserving heat when they are flying in cooler air at high altitudes. We also examined fluid-preserved specimens representing 122 species from 15 of 18 chiropteran families and radiators appeared present only in species in the family Molossidae, including both sedentary and migratory species and subspecies. Thus, the radiator appears to be a unique trait that may facilitate energy balance and water balance during sustained dispersal, foraging, and long-distance migration. PMID:20811514

  2. The economics of vein disease.

    PubMed

    Sales, Clifford M; Podnos, Joan; Levison, Jonathan

    2007-09-01

    The management of cosmetic vein problems requires a very different approach than that for the majority of most other vascular disorders that occur in a vascular surgery practice. This article focuses on the business aspects of a cosmetic vein practice, with particular attention to the uniqueness of these issues. Managing patient expectations is critical to the success of a cosmetic vein practice. Maneuvering within the insurance can be difficult and frustrating for both the patient and the practice. Practices should use cost accounting principles to evaluate the success of their vein work. Vein surgery--especially if performed within the office--can undergo an accurate break-even analysis to determine its profitability.

  3. [Catheter ablation of atrial fibrillation: Health Technology Assessment Report from the Italian Association of Arrhythmology and Cardiac Pacing (AIAC)].

    PubMed

    Themistoclakis, Sakis; Tritto, Massimo; Bertaglia, Emanuele; Berto, Patrizia; Bongiorni, Maria Grazia; Catanzariti, Domenico; De Fabrizio, Giuseppe; De Ponti, Roberto; Grimaldi, Massimo; Pandozi, Claudio; Tondo, Claudio; Gulizia, Michele

    2011-11-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and significantly impact patients' quality of life, morbidity and mortality. The number of affected patients is expected to increase as well as the costs associated with AF management, mainly driven by hospitalizations. Over the last decade, catheter ablation techniques targeting pulmonary vein isolation have demonstrated to be effective in treating AF and preventing AF recurrence. This Health Technology Assessment report of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) aims to define the current role of catheter ablation of AF in terms of effectiveness, efficiency and appropriateness. On the basis of an extensive review of the available literature, this report provides (i) an overview of the epidemiology, clinical impact and socio-economic burden of AF; (ii) an evaluation of therapeutic options other than catheter ablation of AF; and (iii) a detailed presentation of clinical outcomes and cost-benefit ratio associated with catheter ablation. The costs of catheter ablation of AF in Italy were obtained using a bottom-up analysis of a resource utilization survey of 52 hospitals that were considered a representative sample, including 4 Centers that contributed with additional unit cost information in a separate questionnaire. An analysis of budget impact was also performed to evaluate the impact of ablation on the management costs of AF. Results of this analysis show that (1) catheter ablation is effective, safe and superior to antiarrhythmic drug therapy in maintaining sinus rhythm; (2) the cost of an ablation procedure in Italy typically ranges from €8868 to €9455, though current reimbursement remains insufficient, covering only about 60% of the costs; (3) the costs of follow-up are modest (about 8% of total costs); (4) assuming an adjustment of reimbursement to the real cost of an ablation procedure and a 5-10% increase in the annual rate of ablation procedures, after

  4. Use of a latest-generation vascular plug for peripheral vascular embolization with use of a diagnostic catheter: preliminary clinical experience.

    PubMed

    Mordasini, Pasquale; Szucs-Farkas, Zsolt; Do, Do-Dai; Gralla, Jan; Kettenbach, Joachim; Hoppe, Hanno

    2010-08-01

    The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization. Embolization with the AVP 4 was attempted in 13 patients (11 men) for trauma (n = 7) and other indications (n = 6). Technical success rate, vascular bed, size of catheter, and number and size of AVP 4 devices were recorded. Embolization with the AVP 4 was successful in 10 of 13 patients (77%). In trauma patients (n = 7), embolization of the splenic artery (n = 4), lumbar artery (n = 2), and superior gluteal artery (n = 1) was performed. In other patients, preoperative embolization of the right portal vein (n = 1), a gastric varix after transjugular intrahepatic portosystemic shunt creation (n = 1), an aneurysm of the internal iliac artery (n = 1), and inferior mesenteric artery (IMA) embolization before aneurysm repair (n = 2) was performed. Sizes of the AVP 4 were 4 mm (n = 6), 6 mm (n = 5), and 8 mm (n = 1). In all patients, 4- and 5-F catheters with a 0.038-inch minimum inner lumen were used. In one patient, IMA embolization was attempted via a femoral approach but was unsuccessful as a result of repeated catheter tip dislocation because of acute angle; coils were used instead. Peripheral embolization with the AVP 4 was successful in the majority of patients. Future comparative study is necessary to evaluate this device's benefits over other embolization materials such as earlier-generation AVPs or microcoils. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

  5. A CONTROLLED TECHNIQUE FOR VEIN STRIPPING

    PubMed Central

    Gordon, Milton; Payne, Robert D.

    1953-01-01

    A number of difficulties encountered in vein stripping operations for varicose veins in the legs have been overcome by use of a technique evolved by adaptation and modifications of various reported methods. The stripping instrument is passed from below upward, the valves or branches offering less impediment to its passage in that direction. Inserting the tip of the instrument at the ankle through an incision in the vein while it is still in continuity is easier than introducing it into the end of a transected vein. Ligation of major superficial branches or subfascial division of communicating veins can be readily carried out while the stripper is still in place in the vein. Applying pressure bandages to the entire length of the leg before removing the stripper and the telescoped vein diminishes the chances of ecchymosis yet does not hinder withdrawal of the instrument and the vein. PMID:13106726

  6. Locating difficult veins for venepuncture and cannulation.

    PubMed

    Shaw, Sally Jane

    2017-02-15

    Vein location and assessment are essential to improve the success rates for vascular access. However, problems remain with first attempt success rates for peripheral cannulation and locating difficult veins. Practitioners may not be aware of developments in technology and aids to assist in the location and assessment of veins to achieve vascular access. This article provides an overview of two vein location aids that can be used to locate difficult veins: the IV-eye vein imager and the Vacuderm tourniquet. It discusses the patient factors that can increase the difficulty of vein assessment and location, and emphasises the importance of vessel health and preservation, and vein palpation. Practitioners should be experienced and skilled in the assessment of veins, and they are encouraged to revisit how they locate and assess veins.

  7. [Percutaneous catheter-based implantation of artificial pulmonary valves in patients with congenital heart defects].

    PubMed

    Wyller, Vegard Bruun; Aaberge, Lars; Thaulow, Erik; Døhlen, Gaute

    2011-07-01

    Percutaneous catheter-based implantation of artificial heart valves is a new technique that may supplement surgery and which may be used more in the future. We here report our first experience with implantation of artificial pulmonary valves in children with congenital heart defects. Eligible patients were those with symptoms of heart failure combined with stenosis and/or insufficiency in an established artificial right ventricular outflow tract. The valve was inserted through a catheter from a vein in the groin or neck. Symptoms, echocardiography, invasive measurements and angiography were assessed for evaluation of treatment effect. Our treatment results are reported for the period April 2007-September 2009. Ten patients (seven men and three women, median age 17 years) were assessed. The procedure reduced pressure in the right ventricle (p = 0.008) and resolved the pulmonary insufficiency in all patients. The median time in hospital was two days. No patients had complications that were directly associated with the implantation procedure. One patient developed a pseudoaneurysm in the femoral artery, another had a short-lasting fever two days after the procedure and one patient experienced a stent fracture that required surgery 9 months after the implantation. After 6 months all patients had a reduced pressure gradient in the right ventricular outflow tract (p = 0.008), the pulmonary insufficiency had improved (p = 0.006) and they all reported improval of symptoms. These results persisted for at least 24 months for the four patients who were monitored until then. Percutaneous catheter-based implantation of artificial pulmonary valves improves hemodynamics in the right ventricle of selected patients with congenital heart defects. A randomized controlled study should be undertaken to provide a stronger evidence-base for usefulness of this procedure.

  8. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...

  9. Comparison of external catheters with subcutaneous vascular access ports for chronic vascular access in a porcine model.

    PubMed

    Chuang, Marc; Orvieto, Marcelo; Laven, Brett; Gerber, Glenn; Wardrip, Craig; Ritch, Chad; Shalhav, Arieh

    2005-03-01

    We sought to compare the outcomes of two chronic vascular access techniques, the externalized catheter and the subcutaneous vascular access port, in pigs. Female farm pigs (n = 30) underwent placement of a chronic vascular access device in the jugular vein for a research protocol: 18 of the animals underwent placement of a tunneled Hickman catheter (THC), and the remaining 12 animals underwent placement of a subcutaneous vascular access port (VAP) without external components. After placement of the devices, animals underwent serial blood sampling. All animals were given identical antibiotic prophylaxis. VAP access required the use of a restraint sling for Huber needle insertion, whereas THC access required no additional equipment. Animals were euthanatized 1 month after placement of the device. In the VAP group, the port was retrieved, cleaned, and steam-autoclaved for reuse. In the THC group, 13 (72%) animals developed infectious complications, and blood and wound cultures were often polymicrobial. One animal was euthanatized secondary to overwhelming sepsis. In addition, three (17%) animals developed thromboembolic complications. In contrast, no thromboembolic complications were noted in the VAP group, and only one animal developed a transient fever which resolved spontaneously; no septic complications or abscesses developed. Blood draws with no anesthesia were successful in both groups. We conclude that subcutaneous vascular access ports are a safe and efficient method for obtaining reliable chronic vascular access for a 1-month period in pigs. The subcutaneous devices were associated with low morbidity. In contrast, externalized catheters can be associated with considerable morbidity.

  10. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  11. Silicon sensors for catheters and guide wires

    NASA Astrophysics Data System (ADS)

    Goosen, Hans F.

    2001-11-01

    One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.

  12. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  13. Detection of electrophysiology catheters in noisy fluoroscopy images.

    PubMed

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  14. Rescue pulmonary vein isolation for hemodynamically unstable atrial fibrillation storm in a patient with an acute extensive myocardial infarction.

    PubMed

    Morishima, Itsuro; Sone, Takahito; Tsuboi, Hideyuki; Mukawa, Hiroaki

    2012-11-26

    New-onset atrial fibrillation in patients hospitalized for an acute myocardial infarction often leads to hemodynamic deterioration and has serious adverse prognostic implications; mortality is particularly high in patients with congestive heart failure and/or a reduced left ventricular ejection fraction. The mechanism of atrial fibrillation in the context of an acute myocardial infarction has not been well characterized and an effective treatment other than optimal medical therapy and mechanical hemodynamic support are expected. A 71 year-old male with an acute myocardial infarction due to an occlusion of the left main coronary artery was treated with percutaneous coronary intervention. He had developed severe congestive heart failure with a left ventricular ejection fraction of 34%. The systemic circulation was maintained with an intraaortic balloon pump, continuous hemodiafiltration, and mechanical ventilation until atrial fibrillation occurred on day 3 which immediately led to cardiogenic shock. Because atrial fibrillation was refractory to intravenous amiodarone, beta-blockers, and a total of 15 electrical cardioversions, the patient underwent emergent radiofrequency catheter ablation on day 4. Soon after electrical cardioversion, ectopies from the right superior pulmonary vein triggered the initiation of atrial fibrillation. The right pulmonary veins were isolated during atrial fibrillation. Again, atrial fibrillation was electrically cardioverted, then, sinus rhythm was restored. Subsequently, the left pulmonary veins were isolated. The stabilization of the hemodynamics was successfully achieved with an increase in the blood pressure and urine volume. Hemodiafiltration and amiodarone were discontinued. The patient had been free from atrial fibrillation recurrence until he suddenly died due to ventricular fibrillation on day 9. To the best of our knowledge, this is the first report of pulmonary vein isolation for a rescue purpose applied in a patient with

  15. [Unilateral pleural effusion caused by vessel perforation due to peripherally inserted central catheter: Indocyanine green as a diagnostic tool].

    PubMed

    Álvarez-Baena, L; Duque, P; Ramos, R; Zarain Obrador, L; Fernández-Quero, L

    2016-01-01

    A peripherally inserted central catheter (PICC) was inserted into a 44-year-old man to provide parenteral nutrition in a protein-calorie malnutrition secondary to a benign pyloric stenosis. On the fifth day while monitoring the catheter, the patient presented with a massive whitish pleural effusion after undergoing gastric endoscopy in order to treat pyloric stenosis. Chylothorax was initially suspected, and the patient was admitted to a recovery unit. Indocyanine green was administered through the PICC, obtaining a greenish discoloration in the pleural effusion 30 min later. This led to the diagnosis of a pleural effusion caused by a vessel perforation due to the PICC, leading to parenteral nutrition extravasation. Thoraco-abdominal computed tomography was performed, which confirmed an innominate vein perforation due to the PICC. PICC insertion may be associated with severe complications, such as central vessel perforation, and therefore the correct position of a central catheter should be always checked. Intravenous computed tomography contrast is the gold standard for central vascular perforation diagnosis. However if a pleural effusion occurs in this context, it is possible to use a dye, which administered intravenously can lead us to the correct diagnosis in situ. Indocyanine green was used for this purpose in this case. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Mechanochemical endovenous ablation of saphenous veins using the ClariVein: A systematic review.

    PubMed

    Witte, Marianne E; Zeebregts, Clark J; de Borst, Gert Jan; Reijnen, Michel M P J; Boersma, Doeke

    2017-12-01

    Objective To systematically review all available English literature on mechanochemical endovenous ablation and to report on the anatomical, technical, and clinical success. Methods A systematic literature search was performed in PubMed, EMBASE, and the Cochrane Library on mechanochemical endovenous ablation for the treatment of insufficient great and/or small saphenous vein. Methodological quality of the included studies was evaluated using the MINORS score. The primary outcome measure was anatomical success, defined as closure of the treated vein on follow-up duplex ultrasound imaging. Secondary outcomes were technical and clinical success, and major complications defined as deep venous thrombosis, pulmonary embolisms or paresthesia. Results The literature search identified 759 records, of which 13 were included, describing 10 unique cohorts. A total of 1521 veins (1267 great saphenous vein and 254 small saphenous vein) were included, with cohort sizes ranging from 30 to 570 veins. The pooled anatomical success rate after short-term follow up was 92% (95% CI 90-94%) ( n = 1314 veins). After 6 and 12 months these numbers were 92% (95% CI 88-95%) ( n = 284) and 91% (95% CI 86-94%) ( n = 228), respectively. The long-term anatomical success rates at 2 and 3 years were 91% (95% CI 85-95%) ( n = 136) and 87% (95% CI 75-94%) ( n = 48), respectively. Major complications and especially nerve injury were very rare (≤ 0.2%). All studies were of moderate or good quality using the MINORS scoring scale. Conclusions Mechanochemical endovenous ablation using the ClariVein in combination with liquid sclerosant is associated with an anatomical success rate ranging from 87% to 92% and good clinical success. To date, no randomized controlled trials are available studying the anatomical success after mechanochemical ablation, compared to the endothermal ablation. The risk of major complications is very low after the procedure.

  17. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    PubMed

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  18. Femoral vein injury managed by in situ saphenous vein bypass : a case report.

    PubMed

    Coppin, Th; Kuhnle, M

    2014-01-01

    Injured veins of the lower limbs may cause massive haemorrhage requiring early control. Operative management of injured veins remains a controversial topic and reconstruction or ligation depends on venous and adjacent tissue damage. Nevertheless, venous reconstruction seems to reduce the complications of venous ligation. The case of a 33 year old women with a venous wound to the right groin is presented. Surgical management consisted of controlling the bleeding and venous revascularisation with an in situ saphenous vein bypass to substitute the injured femoral vein. The patient had an uneventful postoperative period without any complications. The case demonstrates this method of vascular venous repair is the preferable one. Copyright© Acta Chirurgica Belgica.

  19. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  20. Arabidopsis thaliana Ei-5: Minor Vein Architecture Adjustment Compensates for Low Vein Density in Support of Photosynthesis.

    PubMed

    Stewart, Jared J; Polutchko, Stephanie K; Demmig-Adams, Barbara; Adams, William W

    2018-01-01

    An Arabidopsis thaliana accession with naturally low vein density, Eifel-5 (Ei-5), was compared to Columbia-0 (Col-0) with respect to rosette growth, foliar vein architecture, photosynthesis, and transpiration. In addition to having to a lower vein density, Ei-5 grew more slowly, with significantly lower rates of rosette expansion, but had similar capacities for photosynthetic oxygen evolution on a leaf area basis compared to Col-0. The individual foliar minor veins were larger in Ei-5, with a greater number of vascular cells per vein, compared to Col-0. This compensation for low vein density resulted in similar values for the product of vein density × phloem cell number per minor vein in Ei-5 and Col-0, which suggests a similar capacity for foliar sugar export to support similar photosynthetic capacities per unit leaf area. In contrast, the product of vein density × xylem cell number per minor vein was significantly greater in Ei-5 compared to Col-0, and was associated not only with a higher ratio of water-transporting tracheary elements versus sugar-transporting sieve elements but also significantly higher foliar transpiration rates per leaf area in Ei-5. In contrast, previous studies in other systems had reported higher ratios of tracheary to sieve elements and higher transpiration rate to be associated with higher - rather than lower - vein densities. The Ei-5 accession thus further underscores the plasticity of the foliar vasculature by illustrating an example where a higher ratio of tracheary to sieve elements is associated with a lower vein density. Establishment of the Ei-5 accession, with a low vein density but an apparent overcapacity for water flux through the foliar xylem network, may have been facilitated by a higher level of precipitation in its habitat of origin compared to that of the Col-0 accession.

  1. Varicose Veins, Deep Vein Thrombosis, and Haemorrhoids: Epidemiology and Suggested Aetiology

    PubMed Central

    Burkitt, Denis P.

    1972-01-01

    Current concepts on the aetiology of varicose veins, deep vein thrombosis, and haemorrhoids have been examined and, in the light of epidemiological evidence, found wanting. It is suggested that the fundamental cause of these disorders is faecal arrest which is the result of a low-residue diet. PMID:5032782

  2. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  3. Scattering Removal for Finger-Vein Image Restoration

    PubMed Central

    Yang, Jinfeng; Zhang, Ben; Shi, Yihua

    2012-01-01

    Finger-vein recognition has received increased attention recently. However, the finger-vein images are always captured in poor quality. This certainly makes finger-vein feature representation unreliable, and further impairs the accuracy of finger-vein recognition. In this paper, we first give an analysis of the intrinsic factors causing finger-vein image degradation, and then propose a simple but effective image restoration method based on scattering removal. To give a proper description of finger-vein image degradation, a biological optical model (BOM) specific to finger-vein imaging is proposed according to the principle of light propagation in biological tissues. Based on BOM, the light scattering component is sensibly estimated and properly removed for finger-vein image restoration. Finally, experimental results demonstrate that the proposed method is powerful in enhancing the finger-vein image contrast and in improving the finger-vein image matching accuracy. PMID:22737028

  4. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  5. Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.

    PubMed

    Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim

    2017-05-01

    Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    PubMed

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  7. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    PubMed

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Bacteria on catheters in patients undergoing peritoneal dialysis.

    PubMed

    Pihl, Maria; Davies, Julia R; Johansson, Ann-Cathrine; Svensäter, Gunnel

    2013-01-01

    Peritonitis is the leading cause of morbidity for peritoneal dialysis (PD) patients, and microbial biofilms have previously been identified on catheters from infected patients. However, few studies of catheters from patients without clinical signs of infection have been undertaken. The aim of the present study was to investigate the extent to which bacteria are present on catheters from PD patients with no symptoms of infection. Microbiologic culturing under aerobic and anaerobic conditions and confocal laser scanning microscopy were used to determine the distribution of bacteria on PD catheters from 15 patients without clinical signs of infection and on catheters from 2 infected patients. The 16S rRNA gene sequencing technique was used to identify cultured bacteria. Bacteria were detected on 12 of the 15 catheters from patients without signs of infection and on the 2 catheters from infected patients. Single-species and mixed-microbial communities containing up to 5 species were present on both the inside and the outside along the whole length of the colonized catheters. The bacterial species most commonly found were the skin commensals Staphylococcus epidermidis and Propionibacterium acnes, followed by S. warneri and S. lugdunensis. The strains of these micro-organisms, particularly those of S. epidermidis, varied in phenotype with respect to their tolerance of the major classes of antibiotics. Bacteria were common on catheters from patients without symptoms of infection. Up to 4 different bacterial species were found in close association and may represent a risk factor for the future development of peritonitis in patients hosting such micro-organisms.

  9. Magnetic Catheter Manipulation in the Interventional MRI Environment

    PubMed Central

    Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.

    2013-01-01

    Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097

  10. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  11. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  12. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  13. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  14. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    PubMed

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  15. Catheter placement for lysis of spontaneous intracerebral hematomas: is a navigated stylet better than pointer-guided frameless stereotaxy for intrahematomal catheter positioning?

    PubMed

    Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit

    2014-06-01

    The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.

  16. [Incidence and risk factors for infections from hemodialysis catheters].

    PubMed

    Jean, G

    2001-01-01

    We report here a revue of hemodialysis catheter-related infections data published since 1985. The reported prevalence of bacteremia is 1 to 20% of catheters, and incidence is 0.72 to 9/1000 catheter-days. Local infection is reported in 6 to 63% of catheters and in 1 to 5/1000 catheter-days. Tunneled catheters and implantables chambers reported less infection rate. The most severe complication is endocarditis (4% rate). Death occurs in 8 to 20% of cases. Reported microbial data show that Staphylococcus aureus (SA) is responsible for most infections ahead of non-aureus Staphylococcus. SA skin colonisation is a risk factor for catheter colonisation and the first step of infection. On the other hand, the host immunity impairment in hemodialysis patients seems a significant risk factor. Iron overload, specially after blood transfusions, older age, diabetes mellitus, low serum albumin level, previous history of bacteremia and immunosuppressive treatment have been frequently involved. Other catheter-related factors are time of use, absence of tunnel and use for parenteral nutrition. Nurses plans, dressing type and frequency, nurses work experience are also important. In spite of recent progress in risk factor understanding, hemodialysis-related infection remains frequent. Multicentre studies are necessary to better evaluated care protocols and new catheter material.

  17. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    PubMed

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  18. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  19. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  20. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  1. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  2. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    PubMed Central

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700

  3. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    PubMed

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  4. Tail gut cyst.

    PubMed

    Rao, G Mallikarjuna; Haricharan, P; Ramanujacharyulu, S; Reddy, K Lakshmi

    2002-01-01

    The tail gut is a blind extension of the hindgut into the tail fold just distal to the cloacal membrane. Remnants of this structure may form tail gut cyst. We report a 14-year-old girl with tail gut cyst that presented as acute abdomen. The patient recovered after cyst excision.

  5. Randomized Study Comparing the Effect of Carbon Dioxide Insufflation on Veins Using 2 Types of Endoscopic and Open Vein Harvesting.

    PubMed

    Krishnamoorthy, Bhuvaneswari; Critchley, William R; Nair, Janesh; Malagon, Ignacio; Carey, John; Barnard, James B; Waterworth, Paul D; Venkateswaran, Rajamiyer V; Fildes, James E; Caress, Ann L; Yonan, Nizar

    The aim of the study was to assess whether the use of carbon dioxide insufflation has any impact on integrity of long saphenous vein comparing 2 types of endoscopic vein harvesting and traditional open vein harvesting. A total of 301 patients were prospectively randomized into 3 groups. Group 1 control arm of open vein harvesting (n = 101), group 2 closed tunnel (carbon dioxide) endoscopic vein harvesting (n = 100) and Group 3 open tunnel (carbon dioxide) endoscopic vein harvesting (open tunnel endoscopic vein harvesting) (n = 100). Each group was assessed to determine the systemic level of partial arterial carbon dioxide, end-tidal carbon dioxide, and pH. Three blood samples were obtained at baseline, 10 minutes after start of endoscopic vein harvesting, and 10 minutes after the vein was retrieved. Vein samples were taken immediately after vein harvesting without further surgical handling to measure the histological level of endothelial damage. A modified validated endothelial scoring system was used to compare the extent of endothelial stretching and detachment. The level of end-tidal carbon dioxide was maintained in the open tunnel endoscopic vein harvesting and open vein harvesting groups but increased significantly in the closed tunnel endoscopic vein harvesting group (P = 0.451, P = 0.385, and P < 0.001). Interestingly, partial arterial carbon dioxide also did not differ over time in the open tunnel endoscopic vein harvesting group (P = 0.241), whereas partial arterial carbon dioxide reduced significantly over time in the open vein harvesting group (P = 0.001). A profound increase in partial arterial carbon dioxide was observed in the closed tunnel endoscopic vein harvesting group (P < 0.001). Consistent with these patterns, only the closed tunnel endoscopic vein harvesting group demonstrated a sudden drop in pH over time (P < 0.001), whereas pH remained stable for both open tunnel endoscopic vein harvesting and open vein harvesting groups (P = 0.105 and P

  6. Telling tails: selective pressures acting on investment in lizard tails.

    PubMed

    Fleming, Patricia A; Valentine, Leonie E; Bateman, Philip W

    2013-01-01

    Caudal autotomy is a common defense mechanism in lizards, where the animal may lose part or all of its tail to escape entrapment. Lizards show an immense variety in the degree of investment in a tail (i.e., length) across species, with tails of some species up to three or four times body length (snout-vent length [SVL]). Additionally, body size and form also vary dramatically, including variation in leg development and robustness and length of the body and tail. Autotomy is therefore likely to have fundamentally different effects on the overall body form and function in different species, which may be reflected directly in the incidence of lost/regenerating tails within populations or, over a longer period, in terms of relative tail length for different species. We recorded data (literature, museum specimens, field data) for relative tail length (n=350 species) and the incidence of lost/regenerating tails (n=246 species). We compared these (taking phylogeny into account) with intrinsic factors that have been proposed to influence selective pressures acting on caudal autotomy, including body form (robustness, body length, leg development, and tail specialization) and ecology (foraging behavior, physical and temporal niches), in an attempt to identify patterns that might reflect adaptive responses to these different factors. More gracile species have relatively longer tails (all 350 spp., P < 0.001; also significant for five of the six families tested separately), as do longer (all species, P < 0.001; Iguanidae, P < 0.05; Lacertidae, P < 0.001; Scindidae, P < 0.001), climbing (all species, P < 0.05), and diurnal (all species, P < 0.01; Pygopodidae, P < 0.01) species; geckos without specialized tails (P < 0.05); or active-foraging skinks (P < 0.05). We also found some relationships with the data for caudal autotomy, with more lost/regenerating tails for nocturnal lizards (all 246 spp., P < 0.01; Scindidae, P < 0.05), larger skinks (P < 0.05), climbing geckos (P < 0

  7. Vein visualization: patient characteristic factors and efficacy of a new infrared vein finder technology.

    PubMed

    Chiao, F B; Resta-Flarer, F; Lesser, J; Ng, J; Ganz, A; Pino-Luey, D; Bennett, H; Perkins, C; Witek, B

    2013-06-01

    We investigated the patient characteristic factors that correlate with identification of i.v. cannulation sites with normal eyesight. We evaluated a new infrared vein finding (VF) technology device in identifying i.v. cannulation sites. Each subject underwent two observations: one using the conventional method (CM) of normal, unassisted eyesight and the other with the infrared VF device, VueTek's Veinsite™ (VF). A power analysis for moderate effect size (β=0.95) required 54 samples for within-subject differences. Patient characteristic profiles were obtained from 384 subjects (768 observations). Our sample population exhibited an overall average of 5.8 [95% confidence interval (CI) 5.4-6.2] veins using CM. As a whole, CM vein visualization were less effective among obese [4.5 (95% CI 3.8-5.3)], African-American [4.6 (95% CI 3.6-5.5 veins)], and Asian [5.1 (95% CI 4.1-6.0)] subjects. Next, the VF technology identified an average of 9.1 (95% CI 8.6-9.5) possible cannulation sites compared with CM [average of 5.8 (95% CI 5.4-6.2)]. Seventy-six obese subjects had an average of 4.5 (95% CI 3.8-5.3) and 8.2 (95% CI 7.4-9.1) veins viewable by CM and VF, respectively. In dark skin subjects, 9.1 (95% CI 8.3-9.9) veins were visible by VF compared with 5.4 (95% CI 4.8-6.0) with CM. African-American or Asian ethnicity, and obesity were associated with decreased vein visibility. The visibility of veins eligible for cannulation increased for all subgroups using a new infrared device.

  8. Focus on Varicose Veins

    MedlinePlus

    ... veins no longer work. Under the pressure of gravity these veins can continue to expand and, in ... flow from the legs toward the heart against gravity, while preventing reverse flow back down the legs. ...

  9. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    PubMed

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  10. Biophysics and pathology of catheter energy delivery systems.

    PubMed

    Nath, S; Haines, D E

    1995-01-01

    Catheter ablation has rapidly emerged as the treatment of choice for many symptomatic cardiac arrhythmias. The initial experience with catheter ablation used high-energy DC as the energy source. However, over the last several years radiofrequency (RF) catheter ablation has become the dominant mode of energy delivery. Currently, a major limitation of RF ablation is the small lesion size created by this technique that has reduced its success rate in ablation of larger arrhythmogenic substrates such as coronary artery disease-related ventricular tachycardia. Alternate energy sources such as microwave or ultrasound catheter ablation are being developed that have the potential for producing larger lesions than RF ablation. This review will discuss the biophysics and pathophysiology of the various energy modalities used in catheter ablation.

  11. Leaf hydraulic conductance varies with vein anatomy across Arabidopsis thaliana wild-type and leaf vein mutants.

    PubMed

    Caringella, Marissa A; Bongers, Franca J; Sack, Lawren

    2015-12-01

    Leaf venation is diverse across plant species and has practical applications from paleobotany to modern agriculture. However, the impact of vein traits on plant performance has not yet been tested in a model system such as Arabidopsis thaliana. Previous studies analysed cotyledons of A. thaliana vein mutants and identified visible differences in their vein systems from the wild type (WT). We measured leaf hydraulic conductance (Kleaf ), vein traits, and xylem and mesophyll anatomy for A. thaliana WT (Col-0) and four vein mutants (dot3-111 and dot3-134, and cvp1-3 and cvp2-1). Mutant true leaves did not possess the qualitative venation anomalies previously shown in the cotyledons, but varied quantitatively in vein traits and leaf anatomy across genotypes. The WT had significantly higher mean Kleaf . Across all genotypes, there was a strong correlation of Kleaf with traits related to hydraulic conductance across the bundle sheath, as influenced by the number and radial diameter of bundle sheath cells and vein length per area. These findings support the hypothesis that vein traits influence Kleaf , indicating the usefulness of this mutant system for testing theory that was primarily established comparatively across species, and supports a strong role for the bundle sheath in influencing Kleaf . © 2015 John Wiley & Sons Ltd.

  12. Outcomes after cryoablation vs. radiofrequency in patients with paroxysmal atrial fibrillation: impact of pulmonary veins anatomy.

    PubMed

    Khoueiry, Z; Albenque, J-P; Providencia, R; Combes, S; Combes, N; Jourda, F; Sousa, P A; Cardin, C; Pasquie, J-L; Cung, T T; Massin, F; Marijon, E; Boveda, S

    2016-09-01

    Pulmonary vein isolation is the mainstay of treatment in catheter ablation of paroxysmal atrial fibrillation (AF). Cryoballoon ablation has been introduced more recently than radiofrequency ablation, the standard technique in most centres. Pulmonary veins frequently display anatomical variants, which may compromise the results of cryoballoon ablation. We aimed to evaluate the mid-term outcomes of cryoballoon ablation in an unselected population with paroxysmal AF from an anatomical viewpoint. Consecutive patients with paroxysmal AF who underwent a first procedure of cryoballoon ablation or radiofrequency were enrolled in this single-centre study. All patients underwent systematic standardized follow-up. Comparisons between radiofrequency and cryoballoon ablation (Arctic Front™ or Arctic Front Advance™) were performed regarding safety and efficacy endpoints, according to pulmonary vein (PV) anatomical variants. A total of 687 patients were enrolled (376 radiofrequency and 311 cryoballoon ablation). Baseline characteristics and distribution of PV anatomical variants were generally similar in the groups. After a mean follow-up of 14 ± 8 months, there was no difference in the incidence of relapse (17.0% cryoballoon ablation vs. 14.1% radiofrequency, P = 0.25). We observed no interaction of PV anatomical variants on mid-term procedural success. Our findings suggest that mid-term outcomes of cryoballoon ablation for paroxysmal AF ablation are similar to those of radiofrequency, regardless of PV anatomy. The presence of anatomical variants of PVs should not discourage the referral of patients with paroxysmal AF for cryoballoon ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  13. Pacing threshold changes after transvenous catheter countershock.

    PubMed

    Yee, R; Jones, D L; Klein, G J

    1984-02-01

    The serial changes in pacing threshold and R-wave amplitude were examined after insertion of a countershock catheter in 12 patients referred for management of recurrent ventricular tachyarrhythmias. In 6 patients, values before and immediately after catheter countershock were monitored. Pacing threshold increased (from 1.4 +/- 0.2 to 2.4 +/- 0.5 V, mean +/- standard error of the mean, p less than 0.05) while the R-wave amplitude decreased (bipolar R wave from 5.9 +/- 1.1 to 3.4 +/- 0.7 mV, p less than 0.01; unipolar R wave recorded from the distal ventricular electrode from 8.9 +/- 1.8 to 4.6 +/- 1.2 mV, p less than 0.01; and proximal ventricular electrode from 7.7 +/- 1.5 to 5.0 +/- 1.0 mV, p less than 0.01). A return to control values occurred within 10 minutes. In all patients, pacing threshold increased by 154 +/- 30% (p less than 0.001) during the first 7 days that the catheter was in place. It is concluded that catheter countershock causes an acute increase in pacing threshold and decrease in R-wave amplitude. A catheter used for countershock may not be acceptable as a backup pacing catheter.

  14. General anesthesia with methoxyflurane given intravenously to the dog.

    PubMed

    Hilwig, R W

    1976-03-01

    Dogs were anesthetized with liquid methoxyflurane administered intravenously by gaseous diffusion through sealed medical grade silicone rubber tubing placed in the femoral vein. A similar catheter placed in the other femoral vein and connected to a pressure transducer measured the increase in intraluminal pressure due to methoxyflurane diffusion into the 2nd catheter from the bloodstream 20 seconds after the catheter was flushed with room air. These pressures were plotted against venous blood methoxyflurane concentration, as determined by gas chromatography, for increasing lengths of anesthetic-administering catheter exposed to the bloodstream.

  15. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  16. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  17. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  18. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  19. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    PubMed

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  20. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  1. Concerns and Discomforts of Pregnancy - Varicose Veins

    MedlinePlus

    Concerns and Discomforts of Pregnancy - Varicose Veins Varicose veins are enlarged veins you may see on your ... Healthy Roads Media project www. healthyroadsmedia. org English - Concerns and Discomforts of Pregnancy (Varicose Veins) Last reviewed ...

  2. 5-Year Outcome of Pulmonary Vein Isolation by Loss of Pace Capture on the Ablation Line Versus Electrical Circumferential Pulmonary Vein Isolation.

    PubMed

    Moser, Julia; Sultan, Arian; Lüker, Jakob; Servatius, Helge; Salzbrunn, Tim; Altenburg, Manuel; Schäffer, Benjamin; Schreiber, Doreen; Akbulak, Ruken Ö; Vogler, Julia; Hoffmann, Boris A; Willems, Stephan; Steven, Daniel

    2017-11-01

    This study sought to compare long-term arrhythmia-free survival between electrical circumferential pulmonary vein isolation (PVI) and PVI with the endpoint of unexcitability along the ablation line. PVI is the standard ablation strategy of paroxysmal atrial fibrillation, although arrhythmia recurrence in long-term follow-up (FU) is high. The endpoint of unexcitability along the ablation line results in decreased arrhythmia recurrence compared to electrical PVI in 1-year FU. Seventy-four consecutive patients (age 62.5 ± 10.6 years; 70.3% male) with de novo paroxysmal atrial fibrillation who were initially included in our randomized trial and underwent catheter ablation at our institution were analyzed. Patients who were randomized to either a conventional group (PVI, guided by circumferential catheter signals) or a pace-guided group (PG, anatomical ablation line encircling, ablation until loss of pace capture at 10 V, 2-ms pulse width on the ablation line) underwent long-term FU. The primary endpoint was recurrence of any atrial fibrillation or atrial tachycardia after a blanking period of 3 months. Sixty-nine patients completed a mean FU period of 5.14 ± 0.98 years. Arrhythmia-free survival without antiarrhythmic drug therapy was significantly higher in the PG group (71.05% vs. 25.81%, p = 0.002). Furthermore, multiple procedure success (1.29 ± 0.61 procedures in PG vs. 1.97 ± 1.06 procedures in conventional group, p < 0.001) was higher in the PG group compared to the conventional group (89.47% vs. 58.06%, p = 0.005). The endpoint of unexcitability along the PVI line improves success rates, resulting in a significant reduction of exposure to invasive procedures in 5-year FU. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Corrosion cast study of the canine hepatic veins.

    PubMed

    Uršič, M; Vrecl, M; Fazarinc, G

    2014-11-01

    This study presents a detailed description of the distribution, diameters and drainage patterns of hepatic veins on the basis of the corrosion cast analysis in 18 dogs. We classified the hepatic veins in three main groups: the right hepatic veins of the caudate process and right lateral liver lobe, the middle hepatic veins of the right medial and quadrate lobes and the left hepatic veins of both left liver lobes and the papillary process. The corrosion cast study showed that the number of the veins in the Nomina Anatomica Veterinaria and most anatomical textbooks is underestimated. The number of various-sized hepatic veins of the right liver division ranged from 3 to 5 and included 1 to 4 veins from the caudate process and 2 to 4 veins from the right lateral liver lobe. Generally, in all corrosion casts, one middle-sized vein from the right part of the right medial lobe, which emptied separately in the caudal vena cava, was established. The other vein was a large-sized vein from the remainder of the central division, which frequently joined the common left hepatic vein from the left liver lobes. The common left hepatic vein was the largest of all the aforementioned hepatic veins.

  4. Fibrinogen release and deposition on urinary catheters placed during urologic procedures

    PubMed Central

    Potretzke, Aaron M.; Schreiber, Henry L.; Park, Alyssa M.; Pinkner, Jerome S.; Caparon, Michael G.; Hultgren, Scott J.; Desai, Alana

    2016-01-01

    Purpose Catheter-associated urinary tract infections (CAUTI) account for ~40% of all hospital-acquired infections worldwide, with more than one million cases diagnosed annually. Recent data from a CAUTI animal model has shown that inflammation induced by catheterization releases host fibrinogen that accumulates on the catheter. Further, Enterococcus faecalis catheter colonization was found to be dependent on EbpA, a fibrinogen binding adhesin. We sought to evaluate this mechanism in a human model. Materials and methods Urinary catheters were collected from human subjects hospitalized for surgical or non-surgical urologic procedures. Catheters were subjected to immunofluorescence analyses by incubating them with anti-fibrinogen antibody and then stained for fluorescence. The fluorescence intensity was compared to standard catheters. Catheters were incubated with strains of Enterococcus faecalis, Staphylococcus aureus, or Candida to assess their binding to fibrinogen-laden catheters. Results Fifty catheters were collected after various surgical and urological procedures. In vivo dwell time ranged from 1 hour to 59 days. All catheters had fibrinogen deposition and its accumulation was dependent on dwell time but not on surgical procedure or catheter material. Catheters were probed ex vivo with E. faecalis, S. aureus, and Candida albicans, which bound to catheters only in those regions where fibrinogen was deposited. Conclusions Taken together, these data show that urinary catheters act as a binding surface for accumulation of fibrinogen, which is released due to inflammation resulting from a urological procedure or from catheter placement, creating a niche that can be exploited by uropathogens to cause CAUTI. PMID:26827873

  5. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance

  6. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    PubMed

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  7. Homestake Vein, False Color

    NASA Image and Video Library

    2011-12-07

    This false-color view of a mineral vein called Homestake comes from the panoramic camera Pancam on NASA Mars Exploration Rover Opportunity. The vein is about the width of a thumb and about 18 inches 45 centimeters long.

  8. Remodelling of the Superior Caval Vein After Angioplasty in an Infant with Superior Caval Vein Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mert, Murat; Saltik, Levent; Gunay, Ilhan

    2004-08-15

    An 8-month old girl was presented with superior caval vein syndrome early after cardiac surgery. Angiography showed severe stenosis of the superior caval vein with 50 mmHg pressure gradient. Following balloon angioplasty, the pressure gradient was reduced to 7 mmHg with some residual stenosis of the superior caval vein. When the patient was reevaluated 5 months after the procedure, angiography revealed a normal diameter of the superior caval vein without a pressure gradient.

  9. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  10. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  11. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  12. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  13. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  14. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  15. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  16. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  17. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  18. What Are Varicose Veins?

    MedlinePlus

    ... most severe with vein stripping and ligation (li-GA-shun). Rarely, this procedure can cause severe pain, infections, blood clots, and scarring. Sclerotherapy Sclerotherapy (SKLER-o-ther-ah-pe) uses a liquid chemical to close off a varicose vein. The ...

  19. How to deal with atrial septal defect closure from right internal jugular vein: Role of venous-arterial circuit for sizing and over-the-wire device implantation.

    PubMed

    Butera, Gianfranco; Lovin, Nicusor; Basile, Domenica Paola

    2017-01-01

    Secundum atrial septum defect (ASD) is the most common congenital heart disease. It is usually treated by a transcatheter approach using a femoral venous access. In case of bilateral femoral vein occlusion, the internal jugular venous approach for ASD closure is an option, in particular in cases where ASD balloon occlusion test and sizing is needed. Here, we report on a new technique for ASD closure using a venous-arterial circuit from the right internal jugular vein to the femoral artery. Two patients (females, 4 and 10 years of age) had occlusion of both femoral veins because of a previous history of pulmonary atresia and intact ventricular septum, for which they underwent percutaneous radiofrequency perforation and balloon angioplasty. These subjects needed balloon occlusion test of a residual ASD to size the hole and to check for hemodynamic suitability to ASD closure. After performing a venous-arterial circuit, a 24 mm St Jude ASD sizing balloon catheter was advanced over the circuit and the defect closed for 15 min to check hemodynamics and size the defect. ASD was closed is hemodinamically suitable. This technique was safe and reliable. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  1. A clinical decision rule and D-dimer testing to rule out upper extremity deep vein thrombosis in high-risk patients.

    PubMed

    van Es, Nick; Bleker, Suzanne M; Di Nisio, Marcello; Kleinjan, Ankie; Beyer-Westendorf, Jan; Camporese, Giuseppe; Kamphuisen, Pieter W; Büller, Harry R; Bossuyt, Patrick M

    2016-12-01

    In a management study, a diagnostic algorithm consisting of a clinical decision rule, D-dimer, and ultrasonography was shown to safely exclude upper extremity deep vein thrombosis (UEDVT). Efficiency may be lower in high-risk subgroups: those with a central venous catheter or pacemaker, inpatients, cancer, and elderly patients. Data of 406 patients with suspected UEDVT enrolled in a prospective management study were used for the present analysis. The aim was to evaluate the efficiency of the algorithm in subgroups, defined as the proportion of patients in whom imaging could be safely withheld based on the combination of a decision rule result indicating "UEDVT unlikely" and a normal D-dimer result. The strategy excluded UEDVT in 87 of 406 patients (21%); ultrasonography was withheld in these patients and none developed UEDVT during 3months of follow-up. In contrast, ultrasonography could be withheld in only 4 of 92 patients with a catheter or pacemaker (4.3%; 95% CI: 1.7% to 11%) and in 4 of 83 inpatients (4.8%; 95% CI: 1.9% to 12%). The efficiency was 11% in patients with cancer and 13% in those older than 75years. Although the combination of a decision rule and D-dimer testing is safe in excluding UEDVT in the overall population of patients with suspected UEDVT, its efficiency appears limited in some subgroups, in particular those with a central venous catheter or pacemaker, and inpatients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. The umbilical and paraumbilical veins of man.

    PubMed

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  3. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  4. A magnetic-resonance-imaging-compatible remote catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Thakur, Yogesh; Haider, Syed; Drangova, Maria

    2013-04-01

    A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within the bore of the magnet. While inside the scanner bore, motion accuracy was characterized during the acquisition of frequently used imaging sequences, including real-time gradient echo. The effect of the catheter navigation system on image signal-to-noise ratio (SNR) was also evaluated. The results show that the master-slave system has a maximum time delay of 41 ± 21 ms in replicating motion; an absolute value error of 2 ± 2° was measured for radial catheter motion replication over 360° and 1.0 ± 0.8 mm in axial catheter motion replication over 100 mm of travel. The worst-case SNR drop was observed to be 2.5%.

  5. Factors associated with peritoneal dialysis catheter complications in children.

    PubMed

    Stewart, Camille L; Acker, Shannon N; Pyle, Laura L; Kulungowski, Ann; Cadnapaphornchai, Melissa; Bruny, Jennifer L; Karrer, Frederick

    2016-01-01

    Peritoneal dialysis (PD) is a common method of renal replacement therapy for children. However, placement of PD catheters has risk, and some are never used. We conducted a retrospective chart review of children with a PD catheter placed between 2000 and 2014. Logistic regression analyses were used to identify covariates associated with complications. We identified 175 children with PD catheters. 110 complications developed in 80 children (45.7%). Complications including unexpected return to the operating room and peritonitis increased as the length of time a catheter was in place increased. Children who weighed <12.4 kg had 3.2 times greater odds of developing a leak (95% CI 1.21-8.63, p=0.02). Twelve children never used their PD catheters, 9 with acute kidney injury (AKI) who recovered from their disease more quickly than expected. No covariate was associated with nonuse. Complications with PD catheters are common and increase the longer catheters are in place. Lower weight children are at greater risk of PD catheter leak. Decreased initial volumes of dialysate in smaller children may mitigate this risk. Nonuse may be reduced if dialysis is permitted the day of placement for children with AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Idiopathic Bilateral External Jugular Vein Thrombosis.

    PubMed

    Hindi, Zakaria; Fadhel, Ehab

    2015-08-20

    Vein thrombosis is mainly determined by 3 factors, which constitute a triad called Virchow's triad: hypercoagulability, stasis, and endothelial injury. Venous thrombosis commonly occurs in the lower extremities since most of the blood resides there and flows against gravity. The veins of the lower extremities are dependent on intact valves and fully functional leg muscles. However, in case of valvular incompetency or muscular weakness, thrombosis and blood stasis will occur as a result. In contrast, the veins of the neck, specially the jugulars, have distensible walls which allow flexibility during respiration. In addition, the blood directly flows downward towards the heart. Nevertheless, many case reports mentioned the thrombosis of internal jugular veins and external jugular veins with identified risk factors. Jugular vein thrombosis has previously been associated in the literature with a variety of medical conditions, including malignancy. This report is of a case of idiopathic bilateral external jugular vein thrombosis in a 21 year-old male construction worker of Southeast Asian origin with no previous medical history who presented with bilateral facial puffiness of gradual onset over 1 month. Doppler ultrasound and computed tomography were used in the diagnosis. Further work-up showed no evidence of infection or neoplasia. The patient was eventually discharged on warfarin. The patient was assessed after 6 months and his symptoms had resolved completely. Bilateral idiopathic external jugular veins thrombosis is extremely rare and can be an indicator of early malignancy or hidden infection. While previous reports in the literature have associated jugular vein thrombosis with malignancy, the present case shows that external jugular vein thrombosis can also be found in persons without malignancy.

  7. Indwelling catheters and medical implants with FXIIIa inhibitors: a novel approach to the treatment of catheter and medical device-related infections

    PubMed Central

    Daneshpour, Nooshin; Collighan, Russell; Perrie, Yvonne; Lambert, Peter; Rathbone, Dan; Lowry, Deborah; Griffin, Martin

    2013-01-01

    Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection and thrombosis (of the catheter or vessel itself) during catheterisation. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalisation and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. PMID:23022540

  8. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  9. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  10. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  11. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  12. Association of thrombophilia and catheter-associated thrombosis in children: a systematic review and meta-analysis.

    PubMed

    Neshat-Vahid, S; Pierce, R; Hersey, D; Raffini, L J; Faustino, E V S

    2016-09-01

    Essentials It is unclear if thrombophilia increases the risk of catheter-associated thrombosis in children. We conducted a meta-analysis on thrombophilia and pediatric catheter-associated thrombosis. Presence of ≥1 trait confers additional risk of venous thrombosis in children with catheters. Limitations of included studies preclude us from recommending routine thrombophilia testing. Background The association between thrombophilia and deep vein thrombosis (DVT) associated with central venous catheter (CVC) use, the most important pediatric risk factor for thrombosis, is unclear in children. Pediatric studies with small sample sizes have reported conflicting results. We sought to evaluate whether, among children with CVCs, thrombophilia increases the risk of CVC-associated DVT (CADVT). Materials and methods We systematically searched MEDLINE, EMBASE, the Web of Science, the Cochrane Central Register for Controlled Trials, PubMed and reference lists for controlled studies published from the inception of the database until September 2015. Included were studies of children aged <21 years with CVCs who were systematically tested for thrombophilic traits that are commonly screened for in clinical practice. Pooled prevalence rates and pooled odds ratios (pORs) of CADVT with thrombophilia were estimated by use of a random effects model. Results We analyzed 16 cohort studies with 1279 children, 277 of whom had CADVT, and with 12 traits tested. There was significant heterogeneity in the included studies. The presence of one or more traits was associated with CADVT (pOR 3.20; 95% confidence interval [CI] 1.56-6.54). Although the prevalence of most traits was < 0.10, children with protein C deficiency, elevated factor VIII levels and the FV Leiden mutation had an increased prevalence of CADVT. The association with thrombophilia seemed to be stronger for symptomatic CADVT (pOR 6.71; 95% CI 1.93-23.37) than for asymptomatic CADVT (pOR 2.14; 95% CI 1.10-4.18). Conclusions On

  13. Multimodal ultrasonographic assessment of leiomyosarcoma of the femoral vein in a patient misdiagnosed as having deep vein thrombosis

    PubMed Central

    Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong

    2017-01-01

    Abstract Rationale: Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. Patient concerns: We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. Diagnoses: She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. Interventions: This patient was treated successfully with surgery. Outcomes: This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. Lessons: The pitfall of misdiagnosing this tumor as DVT is a useful reminder. PMID:29145269

  14. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    PubMed

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  15. The anatomy of the cardiac veins in mice

    PubMed Central

    Ciszek, Bogdan; Skubiszewska, Daria; Ratajska, Anna

    2007-01-01

    Although the cardiac coronary system in mice has been the studied in detail by many research laboratories, knowledge of the cardiac veins remains poor. This is because of the difficulty in marking the venous system with a technique that would allow visualization of these large vessels with thin walls. Here we present the visualization of the coronary venous system by perfusion of latex dye through the right caudal vein. Latex injected intravenously does not penetrate into the capillary system. Murine cardiac veins consist of several principal branches (with large diameters), the distal parts of which are located in the subepicardium. We have described the major branches of the left atrial veins, the vein of the left ventricle, the caudal veins, the vein of the right ventricle and the conal veins forming the conal venous circle or the prepulmonary conal venous arch running around the conus of the right ventricle. The venous system of the heart drains the blood to the coronary sinus (the left cranial caval vein) to the right atrium or to the right cranial caval vein. Systemic veins such as the left cranial caval, the right cranial caval and the caudal vein open to the right atrium. Knowledge of cardiac vein location may help to elucidate abnormal vein patterns in certain genetic malformations. PMID:17553104

  16. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    PubMed

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. The risk factors and clinical outcomes of upper extremity deep vein thrombosis.

    PubMed

    Lee, Jung-Ah; Zierler, Brenda K; Zierler, R Eugene

    2012-02-01

    The prevalence of upper extremity deep vein thrombosis (UEDVT) has shown a dramatic increase with the use of central venous catheters (CVCs) for patient care. The objective of this study was to identify risk factors and clinical outcomes in patients diagnosed with UEDVT at an academic medical center over a 1-year period. Medical records of 373 consecutive patients who underwent upper extremity venous duplex ultrasound (VDU) examination were retrospectively reviewed. A quarter of the patients screened by VDU (94 of 373) had acute UEDVT; 63% presented with arm swelling or arm pain; 48% had cancer; and 93% had indwelling CVCs. Cancer patients with CVCs were more likely to develop UEDVT (48%). Of the 94 UEDVTs, 16% had concurrent lower extremity DVT. The incidence of objectively confirmed pulmonary embolism (PE) was 9% (8 of 94 patients), and the 1-month mortality rate was 6.4%. The majority of patients (80%) with UEDVT received anticoagulation therapy and 20% were not treated. The most common risk factors for UEDVT were indwelling CVCs and a diagnosis of cancer. The incidence rate of PE and mortality rate from UEDVT were not insignificant at 9% and 6%, respectively. There were no institutional screening protocols for patients at risk of UEDVT associated with CVCs. Future research should focus on risk assessment and management protocols for patients at risk of UEDVT. In addition, a comparison of clinical outcomes associated with the type, size, and duration of catheter placement should be conducted in patients at risk of or diagnosed with UEDVT.

  18. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  19. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  20. Catheter-Directed Thrombolysis of Lower Limb Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pianta, Marcus J.; Thomson, Kenneth R., E-mail: k.thomson@alfred.org.au

    2011-02-15

    Late complications of thrombosis of the deep veins in the region between the popliteal vein termination and the confluence of the common iliac veins and inferior vena cava (suprapopliteal deep-vein thrombosis) are common and often unrecognized by those responsible for the initial management. Pharmacomechanical-assisted clearance of the thrombus at the time of first presentation provides the best opportunity for complete recovery with preservation of normal venous valve function and avoidance of recurrent deep-vein thrombosis and postthrombotic syndrome. Recent interventional radiology methods provide for rapid and complete thrombolysis even in some patients in whom thrombolysis was previously considered contraindicated. This reviewmore » describes the methods, safety, and efficacy of acute interventional treatment of suprapopliteal deep-vein thrombosis.« less

  1. The Origin of Fibrous Calcite Veins: Aragonite?

    NASA Astrophysics Data System (ADS)

    Elburg, M. A.; Bons, P. D.

    2005-12-01

    Truly fibrous calcite veins occur mainly in carbonaceous shales and are characterised by high length:width ratios of their fibres (>10). Previous studies on their Sr isotopic geochemistry (Elburg et al., 2002: Geol. Soc. London Spec. Publ. 200, 103-118; Hilgers and Sindern, 2005: Geofluids, in press) have shown that some of the material could be derived from the local wall rock. These studies also showed that the veins were always enriched in Sr compared to the calcite in the host rocks. Aragonite can contain significantly more Sr than calcite, while it also tends to have a fibrous crystal habit. It is therefore possible that the fibrous habit of these veins, which now consist of calcite, are a reflection of their initial aragonitic mineralogy, rather than of any special tectonic regime during their formation. This idea was investigated by analysing the major and trace element geochemistry of selected fibrous and non-fibrous calcite veins from Arkaroola (northern Flinders Ranges, Australia). The fibrous vein analysed for major elements contains less than 1% MgCO3, whereas calcite in the host rock, with which it is in Sr isotopic equilibrium, contains 18% MgCO3. Calcite can contain significant Mg, whereas the aragonitic structure cannot accomodate this ion, so this result is consistent with the idea of an original aragonitic mineralogy of the veins. The fibrous veins show an enrichment in the middle rare earth elements (REE) compared to the calcite in the host rock and blocky veins. In a Post-Archean Average Shale normalised diagram, Eu is more strongly enriched compared to its neighbouring elements in the fibrous veins, but not in the host calcite, blocky veins, or in the silicate fraction of the host rock, suggesting more reducing conditions during fibrous vein formation. This data cannot be used as direct evidence for the fibrous veins' aragonitic mineralogy. It does, however, show that significant differences exist between calcite in host rocks, blocky and

  2. Gold Veins near Great Falls, Maryland

    USGS Publications Warehouse

    Reed, John Calvin; Reed, John C.

    1969-01-01

    Small deposits of native gold are present along an anastomosing system of quartz veins and shear zones just east of Great Falls, Montgomery County, Md. The deposits were discovered in 1861 and were worked sporadically until 1951, yielding more than 5,000 ounces of gold. The vein system and the principal veins within it strike a few degrees west of north, at an appreciable angle to foliation and fold axial planes in enclosing rocks of the Wissahickon Formation of late Precambrian (?) age. The veins cut granitic rocks of Devonian or pre-Devonian age and may be as young as Triassic. Further development of the deposits is unlikely under present economic conditions because of their generally low gold content and because much of the vein system lies on park property, but study of the Great Falls vein system may be useful in the search for similar deposits elsewhere in the Appalachian Piedmont.

  3. Magnetic catheter manipulation in the interventional MR imaging environment.

    PubMed

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  4. Antibiofilm surface functionalization of catheters by magnesium fluoride nanoparticles

    PubMed Central

    Lellouche, Jonathan; Friedman, Alexandra; Lahmi, Roxanne; Gedanken, Aharon; Banin, Ehud

    2012-01-01

    The ability of bacteria to colonize catheters is a major cause of infection. In the current study, catheters were surface-modified with MgF2 nanoparticles (NPs) using a sonochemical synthesis protocol described previously. The one-step synthesis and coating procedure yielded a homogenous MgF2 NP layer on both the inside and outside of the catheter, as analyzed by high resolution scanning electron microscopy and energy dispersive spectroscopy. The coating thickness varied from approximately 750 nm to 1000 nm on the inner walls and from approximately 450 nm to approximately 580 nm for the outer wall. The coating consisted of spherical MgF2 NPs with an average diameter of approximately 25 nm. These MgF2 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. Two bacterial strains most commonly associated with catheter infections, Escherichia coli and Staphylococcus aureus, were cultured in tryptic soy broth, artificial urine and human plasma on the modified catheters. The MgF2 NP-coated catheters were able to significantly reduce bacterial colonization for a period of 1 week compared to the uncoated control. Finally, the potential cytotoxicity of MgF2 NPs was also evaluated using human and mammalian cell lines and no significant reduction in the mitochondrial metabolism was observed. Taken together, our results indicate that the surface modification of catheters with MgF2 NPs can be effective in preventing bacterial colonization and can provide catheters with long-lasting self-sterilizing properties. PMID:22419866

  5. REAR PROFILE OF TAIL FROM SECOND LEVEL OF TAIL DOCK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    REAR PROFILE OF TAIL FROM SECOND LEVEL OF TAIL DOCK STAND, SHOWING AIRCRAFT NUMBER (319), HORIZONTAL STABILIZER, TAIL CONE AND COOLING CTS FOR THE AUXILIARY POWER UNIT (APU), MECHANIC PAUL RIDEOUT IS LOWERING THE BALANCE PANELS ON THE STABILIZERS FOR LUBRICATION AND INSPECTION. - Greater Buffalo International Airport, Maintenance Hangar, Buffalo, Erie County, NY

  6. Positioning of nasobiliary tube using magnet-loaded catheters.

    PubMed

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Theory of porous catheters and their applications in intraparenchymal infusions.

    PubMed

    Raghavan, Raghu; Odland, Rick M

    2017-01-01

    Multiport catheters and catheters with a porous surface have been proposed for intraparenchymal infusions of therapeutics in fluid suspensions. Target diseases include brain cancer and serious neurodegenerative diseases, as well as peripheral tumors, for example in the prostate and the liver. We set up the theory for infusions from such devices, in particular the fluid flow equations which demand a coupling between the flow within the catheter and that in tissue. (Such a coupling is not necessary in the theory of infusion from single port catheters.) The new feature of such catheters, treated by our model, is revealed by infusions into inhomogeneous media. Multiport designs have the potential to overcome the limitation of single port catheters, for which the path of the fluid leaving the port is dominated by the inhomogeneities. We solve these equations for some simple cases to illustrate the key design features of porous catheters that show such advantages. The mathematics required for numerical solution with more realistic assumptions is also developed. We confirm the robustness of such catheters, when the ports are sufficiently resistive, against leakage paths that would compromise the infusions from catheters with one or a few large ports. The methods of this paper can be incorporated into a larger planning system for intraparenchymal infusions involving such devices.

  8. Semi-automated location identification of catheters in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.

    2007-03-01

    Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.

  9. Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.

    PubMed

    Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M

    1984-11-01

    Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.

  10. Portal vein thrombosis in paroxysmal nocturnal haemoglobinuria.

    PubMed

    Tomizuka, H; Hatake, K; Kitagawa, S; Yamashita, K; Arai, H; Miura, Y

    1999-01-01

    A 28-year-old man was hospitalized with nausea, vomiting, abdominal pain and low-grade fever. He had a 6-month history of paroxysmal nocturnal haemoglobinuria (PNH), and laboratory data showed anaemia and liver dysfunction. An abdominal ultrasonography showed ascites and portal vein thrombosis. After receiving antithrombotic treatment, the portal vein thrombosis did not extend. Portal vein thrombosis is very rare but should be considered when we encounter liver dysfunction associated with PNH as well as hepatic vein thrombosis. Ultrasonography is very useful in detecting portal vein thrombosis and facilitating early diagnosis. Warfarin is very effective in preventing exacerbation of portal vein thrombosis in PNH.

  11. Portal Vein Thrombosis

    PubMed Central

    Chawla, Yogesh K.; Bodh, Vijay

    2015-01-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion. PMID:25941431

  12. Potential in vivo UVC disinfection of catheter lumens: estimation of the doses received by the blood flow outside the catheter tip hole.

    PubMed

    Bak, Jimmy; Jørgensen, Thomas M; Helfmann, Jurgen; Gravemann, Ute; Vorontsova, Inessa

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2)). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting. © 2011 Jimmy Bak. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  13. Urethral catheter insertion forces: a comparison of experience and training.

    PubMed

    Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj

    2009-01-01

    This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  14. Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis

    PubMed Central

    Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio

    2013-01-01

    ♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical

  15. Multicenter Cohort Study to Assess the Impact of a Silver-Alloy and Hydrogel-Coated Urinary Catheter on Symptomatic Catheter-Associated Urinary Tract Infections

    PubMed Central

    Lederer, James W.; Jarvis, William R.; Thomas, Lendon

    2014-01-01

    PURPOSE: The purpose of this study was to determine the effect of a silver-alloy hydrogel catheter on symptomatic catheter-associated urinary tract infections (CAUTIs). DESIGN: Multicenter before-after non-randomized cohort study. SUBJECTS AND SETTING: Seven acute care hospitals ranging in size from 124 to 607 beds participated in this study. The study population included adult patients with a positive urine culture 2 or more days after admission, who underwent Foley catheterization. METHODS: Catheter-associated urinary tract infection surveillance was conducted at each hospital for at least 3 months during the use of a standard catheter and 3 months during the use of the silver-alloy hydrogel catheter. Both the National Healthcare Safety Network (NHSN) surveillance and a clinical definition of CAUTI were used for rate calculation. RESULTS: A 47% relative reduction in the CAUTI rate was observed with the silver-alloy hydrogel catheter compared to the standard catheter when both infection definitions were used (0.945/1000 patient days vs 0.498/1000 patient days) (odds ratio = 0.53; P < .0001; 95% CI: 0.45–0.62). When only NHSN-defined CAUTIs were considered, a 58% relative reduction occurred in the silver-alloy hydrogel period (0.60/1000 patient days vs 0.25/1000 patient days) (odds ratio = 0.42; P < .0001; 95% CI: 0.34–0.53). Antimicrobial days for CAUTIs decreased from 1165 (standard catheter period) to 406 (silver-alloy hydrogel period). CONCLUSIONS: Use of a silver-alloy hydrogel urinary catheter reduced symptomatic CAUTI occurrences as defined by both NHSN and clinical criteria. PMID:24922561

  16. The importance of effective catheter securement.

    PubMed

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  17. Assessment of a new hub design and the semiquantitative catheter culture method using an in vivo experimental model of catheter sepsis.

    PubMed Central

    Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A

    1990-01-01

    An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430

  18. Catheter fracture of intravenous ports and its management.

    PubMed

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P < 0.05 was considered statistically significant. There were 59 and 1,448 procedures in the fracture and non-fracture groups, respectively. Monovariate analysis revealed that the risk factors for catheter fracture were as follows: large angle (P < 0.0001), female gender (P < 0.0008), subclavian route (P < 0.0001), and port type Arrow French (Fr.) 8.1 (P < 0.0001). Because these risk factors showed no interaction effects, they were all considered independent risk factors. When all factors were considered together, all risk factors, except angle and age, retained their statistical significance. Most catheter fractures were caused by material weakness. If catheter fracture is confirmed, further intervention for port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  19. Development of Active Catheter,Active Guide Wire and Micro Sensor Systems

    PubMed Central

    Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.

    2001-01-01

    Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389

  20. Natural history of deep vein thrombosis in children.

    PubMed

    Spentzouris, G; Gasparis, A; Scriven, R J; Lee, T K; Labropoulos, N

    2015-07-01

    To determine the natural history of deep vein thrombosis in children presented with a first episode in the lower extremity veins. Children with objective diagnosis of acute deep vein thrombosis were followed up with ultrasound and clinical examination. Risk factors and clinical presentation were prospectively collected. The prevalence of recurrent deep vein thrombosis and the development of signs and symptoms of chronic venous disease were recorded. There were 27 children, 15 males and 12 females, with acute deep vein thrombosis, with a mean age of 4 years, range 0.1-16 years. The median follow-up was 23 months, range 8-62 months. The location of thrombosis involved the iliac and common femoral vein in 18 patients and the femoral and popliteal veins in 9. Only one vein was affected in 7 children, two veins in 14 and more than two veins in 6. Recurrent deep vein thrombosis occurred in two patients, while no patient had a clinically significant pulmonary embolism. Signs and symptoms of chronic venous disease were present at last follow-up in 11 patients. There were nine patients with vein collaterals, but no patient developed varicose veins. Reflux was found in 18 veins of 11 patients. Failure of recanalization was seen in 7 patients and partial recanalization in 11. Iliofemoral thrombosis (p = 0.012) and failure to recanalize (p = 0.036) increased significantly the risk for developing signs and symptoms. Children with acute proximal deep vein thrombosis develop mild chronic venous disease signs and symptoms at mid-term follow-up and are closely related with iliofemoral thrombosis and failure to recanalization. © The Author(s) 2014.