Sample records for tail-cuff blood pressure

  1. Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.

    PubMed

    Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D

    2017-06-27

    Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  2. Evaluation of indirect blood pressure monitoring in awake and anesthetized red-tailed hawks (Buteo jamaicensis): effects of cuff size, cuff placement, and monitoring equipment.

    PubMed

    Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H

    2009-09-01

    To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.

  3. Blood pressure measurement with the tail-cuff method in Wistar and spontaneously hypertensive rats: influence of adrenergic- and nitric oxide-mediated vasomotion.

    PubMed

    Fritz, M; Rinaldi, G

    2008-01-01

    Systolic blood pressure (SBP) is still measured in rats by the tail-cuff method, allowing readings when pulse/flow disappears during cuff inflation and reappears during deflation, separated by a compression interval. Although cuff deflation is habitually used to estimate SBP, we found cuff deflation-cuff inflation pressure to be usually negative, indicating that cuff deflation pressure < cuff inflation pressure. SBP was measured in 226 male Wistar and SHR utilizing compression intervals of different durations, and also pharmacological interventions intended to modulate the cuff deflation-cuff inflation cycle. Direct, simultaneous intravascular measurements were also performed in some animals. With compression interval congruent with 15 s, cuff deflation-cuff inflation was--6 +/- 0.6 mmHg in 73 Wistar and--6 +/- 1.4 mmHg in 51 SHR. Lengthening compression interval up to 4 min increased cuff deflation-cuff inflation pressure significantly to--27 +/- 3 mmHg in Wistar and to - 31 +/- 5 mmHg in SHR, suggesting accumulation of a vasodilating mediator. This increase of cuff deflation-cuff inflation pressure was prevented by papaverine (totally in Wistar, partially in SHR), indicating its dependence on vasodilatory capacity. Adrenergic blockade decreased cuff deflation-cuff inflation pressure to--13 +/- 5 mmHg (P < 0.05) in SHR, but had no effect in Wistar rats. Injection of L-NAME decreased cuff deflation-cuff inflation pressure to--5 +/- 2 mmHg (P < 0.05) in Wistar rats but was ineffective in SHR. Simultaneous measurements by tail-cuff method and carotid cannulation revealed that the cuff inflation most accurately estimated the intravascular SBP. 1) Cuff inflation measurements should be considered representative of SBP, as cuff deflation can underestimate SBP depending on compression interval duration, 2) nitric oxide accumulation due to flow deprivation is the main cause of SBP underestimation by cuff deflation in Wistar, and 3) in SHR, nitric oxide effects were minimal

  4. 21 CFR 870.1120 - Blood pressure cuff.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  5. 21 CFR 870.1120 - Blood pressure cuff.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  6. 21 CFR 870.1120 - Blood pressure cuff.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  7. 21 CFR 870.1120 - Blood pressure cuff.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  8. 21 CFR 870.1120 - Blood pressure cuff.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff...

  9. Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat.

    PubMed

    Fritz, Mariana; Rinaldi, Gustavo

    2007-11-01

    Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def-Inf) to be -6 +/- 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def-Inf) was increased to -17 +/- 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def-Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def-Inf), but pretreatment with L-NAME decreased it to -5 +/- 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values.

  10. Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients.

    PubMed

    Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel

    2007-10-01

    Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of

  11. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    PubMed

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  12. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes.

    PubMed

    Kuo, Chung-Hsien; Wu, Chun-Ju; Chou, Hung-Chyun; Chen, Guan-Ting; Kuo, Yu-Cheng

    2017-01-01

    This paper presents an oscillometric blood pressure (BP) measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP) and diastolic blood pressure (DBP), during the inflating cycle. Two modes of air injection measurement (AIM) and accurate dual-way measurement (ADM) were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation) in the measurements when compared to a commercial BP monitor.

  13. An affordable cuff-less blood pressure estimation solution.

    PubMed

    Jain, Monika; Kumar, Niranjan; Deb, Sujay

    2016-08-01

    This paper presents a cuff-less hypertension pre-screening device that non-invasively monitors the Blood Pressure (BP) and Heart Rate (HR) continuously. The proposed device simultaneously records two clinically significant and highly correlated biomedical signals, viz., Electrocardiogram (ECG) and Photoplethysmogram (PPG). The device provides a common data acquisition platform that can interface with PC/laptop, Smart phone/tablet and Raspberry-pi etc. The hardware stores and processes the recorded ECG and PPG in order to extract the real-time BP and HR using kernel regression approach. The BP and HR estimation error is measured in terms of normalized mean square error, Error Standard Deviation (ESD) and Mean Absolute Error (MAE), with respect to a clinically proven digital BP monitor (OMRON HBP1300). The computed error falls under the maximum standard allowable error mentioned by Association for the Advancement of Medical Instrumentation; MAE <; 5 mmHg and ESD <; 8mmHg. The results are validated using two-tailed dependent sample t-test also. The proposed device is a portable low-cost home and clinic bases solution for continuous health monitoring.

  14. Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff: Implications for noninvasive blood pressure measurement

    NASA Astrophysics Data System (ADS)

    Deng, Zhipeng; Liang, Fuyou

    2016-10-01

    An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement. However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element (FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.

  15. The influence of participant characteristics on the relationship between cuff pressure and level of blood flow restriction.

    PubMed

    Hunt, Julie E A; Stodart, Clare; Ferguson, Richard A

    2016-07-01

    Previous investigations to establish factors influencing the blood flow restriction (BFR) stimulus have determined cuff pressures required for complete arterial occlusion, which does not reflect the partial restriction prescribed for this training technique. This study aimed to establish characteristics that should be accounted for when prescribing cuff pressures required for partial BFR. Fifty participants were subjected to incremental blood flow restriction of the upper and lower limbs by proximal pneumatic cuff inflation. Popliteal and brachial artery diameter, blood velocity and blood flow was assessed with Doppler ultrasound. Height, body mass, limb circumference, muscle-bone cross-sectional area, adipose thickness (AT) and arterial blood pressure were measured and used in different models of hierarchical linear regression to predict the pressure at which 60 % BFR (partial occlusion) occurred. Combined analysis revealed a difference in cuff pressures required to elicit 60 % BFR in the popliteal (111 ± 12 mmHg) and brachial arteries (101 ± 12 mmHg). MAP (r = 0.58) and AT (r = -0.45) were the largest independent determinants of lower and upper body partial occlusion pressures. However, greater variance was explained by upper and lower limb regression models composed of DBP and BMI (48 %), and arm AT and DBP (30 %), respectively. Limb circumference has limited impact on the cuff pressure required for partial blood flow restriction which is in contrast to its recognised relationship with complete arterial occlusion. The majority of the variance in partial occlusion pressure remains unexplained by the predictor variables assessed in the present study.

  16. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    PubMed

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  17. Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation.

    PubMed

    Zheng, Dingchang; Pan, Fan; Murray, Alan

    2013-10-01

    The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P < 0.01), manual DBP was 1.5 mmHg higher (P < 0.01), manual PP was 4.2 mmHg lower (P < 0.001), automated DBP was 6.7 mmHg higher (P < 0.001) and automatic PP was 7.5 mmHg lower (P < 0.001). There was no statistically significant difference for any automated BPs between fast and standard cuff inflation. The statistically significant BP differences between inflation and deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.

  18. Cuff-Free Blood Pressure Estimation Using Pulse Transit Time and Heart Rate.

    PubMed

    Wang, Ruiping; Jia, Wenyan; Mao, Zhi-Hong; Sclabassi, Robert J; Sun, Mingui

    2014-10-01

    It has been reported that the pulse transit time (PTT), the interval between the peak of the R-wave in electrocardiogram (ECG) and the fingertip photoplethysmogram (PPG), is related to arterial stiffness, and can be used to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP). This phenomenon has been used as the basis to design portable systems for continuously cuff-less blood pressure measurement, benefiting numerous people with heart conditions. However, the PTT-based blood pressure estimation may not be sufficiently accurate because the regulation of blood pressure within the human body is a complex, multivariate physiological process. Considering the negative feedback mechanism in the blood pressure control, we introduce the heart rate (HR) and the blood pressure estimate in the previous step to obtain the current estimate. We validate this method using a clinical database. Our results show that the PTT, HR and previous estimate reduce the estimated error significantly when compared to the conventional PTT estimation approach (p<0.05).

  19. Wearable PWV technologies to measure Blood Pressure: eliminating brachial cuffs.

    PubMed

    Solá, J; Proença, M; Chételat, O

    2013-01-01

    The clinical demand for technologies to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is strong: new generation of BP monitors are expected to be not only accurate, but also non-occlusive. In this paper we review recent advances on the use of the so-called Pulse Wave Velocity (PWV) technologies to estimate BP in a beat-by-beat basis. After introducing the working principle and underlying methodological limitations, two implementation examples are provided. Pilot studies have demonstrated that novel PWV-based BP monitors depict accuracy scores falling within the limits of the British Hypertensive Society (BHS) Grade A standard. The reported techniques pave the way towards ambulatory-compliant, continuous and non-occlusive BP monitoring devices, where the use of inflation cuffs is drastically reduced.

  20. Blood Pressure Control

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Engineering Development Laboratory developed a system for the cardiovascular study of weightless astronauts. This was designed to aid people with congestive heart failure and diabetes. While in space, astronauts' blood pressure rises, heart rate becomes unstable, and there are sometimes postflight lightheadedness or blackouts. The Baro-Cuff studies the resetting of blood pressure. When a silicone rubber chamber is strapped to the neck, the Baro-Cuff stimulates the carotid arteries by electronically controlled pressure application. Blood pressure controls in patients may be studied.

  1. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    NASA Astrophysics Data System (ADS)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  2. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.

    PubMed

    Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald

    2016-11-01

    Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH 2 O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH 2 O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. We analyzed data for 55 patients. There was a mean age of 57 years (range 18-90). The mean ETT cuff pressure was 70 (95% CI= [61-80]) cmH 2 O. The mean lies 40 cmH 2 O above the maximum accepted value of 30 cmH 2 O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH 2 O, the maximum pressure on the analog gauge. Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should

  3. Differences and effects of medium and large adult cuffs on blood pressure readings in individuals with muscular arms.

    PubMed

    Fonseca-Reyes, Salvador; Fajardo-Flores, Ismael; Montes-Casillas, Mayra; Forsyth-Macquarrie, Avril

    2009-08-01

    This study analyzed systolic and diastolic blood pressure (SBP and DBP) reading differences in individuals with muscular arms, using medium and large adult cuffs. Resting blood pressures (BPs) were measured in bodybuilders competing at the Mexican National Bodybuilding and Fitness Championship. The means of two bilateral simultaneous arm BP measurements were obtained using two different cuff sizes, 12 cm (medium adult) and 16 cm (large adult). A total of 193 bodybuilders completed the measurements. With an arm circumference greater than 33 cm, the SBP and DBP average taken with the medium adult cuff was higher than that obtained with the large adult cuff, 8.2+/-10.6 and 1.6+/-7.4 mmHg, respectively; however, a significant difference was observed only with the SBP. With the medium adult cuff, 48 of 144 individuals showed SBP at least 140 mmHg, whereas with the large adult cuff there were only 17 of 144 individuals. In those participants with an arm circumference less than 33 cm, the BP was nonsignificantly lower with the large cuff, -4.24+/-9.2 and -2.24+/-5.4 mmHg for the SBP and DBP, respectively. Incorrect cuffing of a muscular arm leads to significant errors in the measurement of SBP and DBP, similar to that observed in miscuffing of nonmuscular arms.

  4. Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: the impact of posture.

    PubMed

    Muehlsteff, J; Aubert, X A; Morren, G

    2008-01-01

    There is an unmet need for cuff-less blood pressure (BP) monitoring especially, in personal healthcare applications. The pulse arrival time (PAT) approach might offer a suitable solution to enable comfortable BP monitoring even at beat-level. However, the methodology is based on hemodynamic surrogate measures, which are sensitive to patient activities such as posture changes, not necessarily related to blood pressure variations. In this paper, we analyze the impact of posture on the PAT measure and related hemodynamic parameters such as the pre-ejection period in well-defined procedures. Additionally, the PAT of a monitored subject is investigated in an unsupervised scenario illustrating the complexity of such a measurement. Our results show the failure of blood pressure inference based on simple calibration strategies using the PAT measure only. We discuss opportunities to compensate for the observed effects towards the realization of wearable cuff-less blood pressure monitoring. These findings emphasize the importance of accessing context information in personal healthcare applications, where vital sign monitoring is typically unsupervised.

  5. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport

    PubMed Central

    Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald

    2016-01-01

    Introduction Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH2O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH2O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. Methods We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. Results We analyzed data for 55 patients. There was a mean age of 57 years (range 18–90). The mean ETT cuff pressure was 70 (95% CI= [61–80]) cmH2O. The mean lies 40 cmH2O above the maximum accepted value of 30 cmH2O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH2O, the maximum pressure on the analog gauge. Conclusion Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow

  6. Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air and Saline Filled Cuffs

    DTIC Science & Technology

    2017-01-31

    AFRL-SA-WP-SR-2017-0004 Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled...Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled Cuffs 5a. CONTRACT NUMBER FA8650-14...descending from altitude. When using saline in the ETT cuff, TW pressure differences with the 7.5 high-volume, low-pressure cuff and 8.0 TaperGuard

  7. LB03.04: SPHYGMOMANOMETER CUFF CONSTRUCTION AND MATERIALS AFFECT TRANSMISSION OF PRESSURE FROM CUFF TO ARTERIAL WALL. FINITE ELEMENT ANALYSIS OF HUMAN PRESSURE MEASUREMENTS AND DICOM DATA.

    PubMed

    Lewis, P; Naqvi, S; Mandal, P; Potluri, P

    2015-06-01

    -arterial pressure 14 mmHg higher than with a fabric bladder.(Figure is included in full-text article.) : Wide variations of pressure within and under cuffs and at the artery wall interface, dependent on differing cuff materials and construction, may critically affect blood pressure measurement.

  8. Cuff-less PPG based continuous blood pressure monitoring: a smartphone based approach.

    PubMed

    Gaurav, Aman; Maheedhar, Maram; Tiwari, Vijay N; Narayanan, Rangavittal

    2016-08-01

    Cuff-less estimation of systolic (SBP) and diastolic (DBP) blood pressure is an efficient approach for non-invasive and continuous monitoring of an individual's vitals. Although pulse transit time (PTT) based approaches have been successful in estimating the systolic and diastolic blood pressures to a reasonable degree of accuracy, there is still scope for improvement in terms of accuracies. Moreover, PTT approach requires data from sensors placed at two different locations along with individual calibration of physiological parameters for deriving correct estimation of systolic and diastolic blood pressure (BP) and hence is not suitable for smartphone deployment. Heart Rate Variability is one of the extensively used non-invasive parameters to assess cardiovascular autonomic nervous system and is known to be associated with SBP and DBP indirectly. In this work, we propose a novel method to extract a comprehensive set of features by combining PPG signal based and Heart Rate Variability (HRV) related features using a single PPG sensor. Further, these features are fed into a DBP feedback based combinatorial neural network model to arrive at a common weighted average output of DBP and subsequently SBP. Our results show that using this current approach, an accuracy of ±6.8 mmHg for SBP and ±4.7 mmHg for DBP is achievable on 1,750,000 pulses extracted from a public database (comprising 3000 people). Since most of the smartphones are now equipped with PPG sensor, a mobile based cuff-less BP estimation will enable the user to monitor their BP as a vital parameter on demand. This will open new avenues towards development of pervasive and continuous BP monitoring systems leading to an early detection and prevention of cardiovascular diseases.

  9. Prenatal malnutrition-induced changes in blood pressure: dissociation of stress and nonstress responses using radiotelemetry.

    PubMed

    Tonkiss, J; Trzcińska, M; Galler, J R; Ruiz-Opazo, N; Herrera, V L

    1998-07-01

    A link between prenatal malnutrition and hypertension in human populations has recently been proposed. Rat models of prenatal malnutrition have provided major support for this theory on the basis of tail-cuff measurements. However, this technique requires restraint and elevated temperature, both potential sources of stress. To determine the effect of prenatal protein malnutrition on blood pressure under nonstress conditions, 24-hour radiotelemetric measurements were taken in the home cage. Male rats born to dams fed a 6% casein diet for 5 weeks before mating and throughout pregnancy were studied in early adulthood (from 96 days of age). During the waking phase of their cycle but not the sleep phase, prenatal malnutrition gave rise to small but significant elevations of diastolic blood pressure and heart rate compared with well-nourished controls. Direct effects of stress on blood pressure responses were determined in a second experiment using an olfactory stressor. Prenatally malnourished rats showed a greater increase in both systolic and diastolic pressures compared with well-nourished controls during the first exposure to ammonia. A different pattern of change of cardiovascular responses was also observed during subsequent presentations of the stressor. These findings of a small baseline increase in diastolic pressure consequent to prenatal malnutrition, but an augmented elevation of both systolic and diastolic pressures after first exposure to stress, suggest the need to reevaluate interpretation of the large elevations in blood pressure previously observed in malnourished animals using the stressful tail-cuff procedure.

  10. Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure

    PubMed Central

    Annoni, Raquel; de Almeida, Antonio Evanir

    2015-01-01

    Objective To test the agreement between two handcrafted devices and a cuff-specific manometer. Methods The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1 and HD2). The data were compared using Wilcoxon and Spearman tests, the intraclass correlation coefficient (ICC) and limit-of-agreement analysis. Results Cuff pressures assessed with handcrafted devices were significantly different from commercial device measurements (pressures were higher when measured with HD1 and lower with HD2). The ICCs between the commercial device and HD1 and HD2 were excellent (ICC = 0.8 p < 0.001) and good (ICC = 0.66, p < 0.001), respectively. However, the Bland- Altman plots showed wide limits of agreement between HD1 and HD2 and the commercial device. Conclusion The handcrafted manometers do not provide accurate cuff pressure measurements when compared to a cuff-specific device and should not be used to replace the commercial cuff manometers in mechanically ventilated patients. PMID:26376160

  11. The correlation between body mass index, limb circumferences and blood pressure cuff fit in bariatric surgical patients.

    PubMed

    Schumann, R; Alyamani, O; Viswanath, A; Bonney, I

    2016-01-01

    The purpose of this study was to determine the correlation between body mass index (BMI) and upper and lower arm as well as lower leg circumferences and the frequency of correct blood pressure (BP) cuff fit. We explored recommendations for the most likely BP cuff size and location for the three BMI categories. Following IRB approval we retrospectively analyzed a research database of bariatric surgical patients with a BMI of ≥40 kg/m(2). Data included patients' characteristics, upper and lower arm as well as lower leg circumferences. Patients were divided into three groups based on BMI (kg/m(2), Group I: <45, Group II: 45-55, and Group III: >55). Appropriate cuff fit using a standard or large adult BP cuff (CRITIKON(®), GE Healthcare, Waukesha, Wisconsin, USA) on the upper and lower arm, and lower leg was determined. We analyzed the percent proportion of proper cuff fit for cuff sizes and locations between groups using appropriate nonparametric testing. Limb circumference correlated significantly with BMI (P = 0.01), and the upper arm correlated most closely (r = 0.76). A standard adult BP cuff on the lower arm fit properly in >90% and >80% and in Groups I and II, respectively. A large cuff on the lower arm was appropriate in 87% of Group III. In two participants, a large cuff fit properly on the lower leg. Limb circumference significantly correlated with BMI. Recommendations for proper cuff fit in different BMI categories can be made.

  12. Automated Blood Pressure Measurement

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Vital-2 unit pictured is a semi-automatic device that permits highly accurate blood pressure measurement, even by untrained personnel. Developed by Meditron Instrument Corporation, Milford, New Hampshire, it is based in part on NASA technology found in a similar system designed for automatic monitoring of astronauts' blood pressure. Vital-2 is an advancement over the familiar arm cuff, dial and bulb apparatus customarily used for blood pressure checks. In that method, the physician squeezes the bulb to inflate the arm cuff, which restricts the flow of blood through the arteries. As he eases the pressure on the arm, he listens, through a stethoscope, to the sounds of resumed blood flow as the arteries expand and contract. Taking dial readings related to sound changes, he gets the systolic (contracting) and diastolic (expanding) blood pressure measurements. The accuracy of the method depends on the physician's skill in interpreting the sounds. Hospitals sometimes employ a more accurate procedure, but it is "invasive," involving insertion of a catheter in the artery.

  13. Measuring Time-Averaged Blood Pressure

    NASA Technical Reports Server (NTRS)

    Rothman, Neil S.

    1988-01-01

    Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.

  14. Blood-Pressure Measuring System Gives Accurate Graphic Output

    NASA Technical Reports Server (NTRS)

    1965-01-01

    The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

  15. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    PubMed Central

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  16. Cuff for Blood-Vessel Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Shimizu, M.

    1982-01-01

    Pressure within blood vessel is measured by new cufflike device without penetration of vessel. Device continuously monitors blood pressure for up to 6 months or longer without harming vessel. Is especially useful for vessels smaller than 4 or 5 millimeters in diameter. Invasive methods damage vessel wall, disturb blood flow, and cause clotting. They do not always give reliable pressure measurements over prolonged periods.

  17. Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise

    NASA Technical Reports Server (NTRS)

    Gallagher, K. M.; Fadel, P. J.; Smith, S. A.; Norton, K. H.; Querry, R. G.; Olivencia-Yurvati, A.; Raven, P. B.

    2001-01-01

    This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.

  18. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    PubMed

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  19. The Effect of Endotracheal Inflation Technique on Endotracheal Cuff Pressure

    DTIC Science & Technology

    1999-10-01

    mucosal pressure had upon tracheal wall blood flow of anesthetized dogs . This study found that low-volume, high-pressure cuffs required 320 to 360 mm...Journal, 288, 965-968. Som, P., Khilnani, M., Keller, R., & Som, M. (1972). Tracheal stenosis secondary to cuffed tubes. Mount Siai Journal of Medicine

  20. Blood pressure cuffs as a vector for transmission of multi-resistant organisms: colonisation rates and effects of disinfection.

    PubMed

    Grewal, Harjeet; Varshney, Kavita; Thomas, Lee C; Kok, Jen; Shetty, Amith

    2013-06-01

    Blood pressure (BP) cuffs are potential vectors for transmission of multi-resistant organisms (MROs). The present study aims to determine MRO colonisation rates in BP cuffs from areas of high patient flow as an assessment of the quality of disinfection and infection control practices. BP cuffs in the ED, high dependency unit (HDU) and operating theatres (OT) were prospectively examined after routine disinfection procedures. Swabs collected from the inner and outer surfaces of BP cuffs during inter-patient intervals were plated onto replicate organism detection and counting, methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) chromogenic agar plates to detect rates of bacterial, MRSA and VRE colonisation, respectively. High bacterial colonisation rates were detected in BP cuffs from all three areas. BP cuffs from OT were significantly less colonised compared with cuffs from HDU and ED; 76% versus 96% and 100% (P < 0.0001) for inner surfaces and 86% versus 98% and 100% (P < 0.0001) for outer surfaces, respectively. Equivalent or higher bacterial growth was observed on the inner surface compared with outer surface in 54%, 84% and 86% of BP cuffs from OT, HDU and ED, respectively. MRSA was detected in 3 of 150 (2%) swabs collected, but no VRE was detected. Although MRSA and VRE were infrequently isolated, current disinfection and infection control protocols need to be improved given the greater recovery of organisms from the inner compared with outer surfaces of BP cuffs. © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  1. The Effect of Endotracheal Inflation Technique on Endotracheal Cuff Pressure

    DTIC Science & Technology

    1999-10-01

    had upon tracheal wall blood flow of anesthetized dogs . This study found that low-volume, high-pressure cuffs required 320 to 360 mm Hg of pressure to...Som, P., Khilnani, M., Keller, R., & Som, M. (1972). Tracheal stenosis secondary to cuffed tubes. Mount Siai Journal of Medicine, 40, 652-665

  2. Automated control of endotracheal tube cuff pressure during simulated flight.

    PubMed

    Blakeman, Thomas; Rodriquez, Dario; Woods, James; Cox, Daniel; Elterman, Joel; Branson, Richard

    2016-11-01

    Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers-Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions-were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8,000 feet and then to 16,000 feet at 2,500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2O. Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2O; Pyton, 25 ± 0.8 cm H2O; Cuff Sentry, 22 ± 0.3 cm H2O; and Intellicuff, 29 ± 6.6 cm H2O. The mean time that cuff pressure was >30 cm H2O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. Therapeutic study, level V.

  3. Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults.

    PubMed

    Chen, Diliang; Chen, Fei; Murray, Alan; Zheng, Dingchang

    2016-05-10

    Accurate blood pressure (BP) measurement depends on the reliability of oscillometric cuff pressure pulses (OscP) and Korotkoff sounds (KorS) for automated oscillometric and manual techniques. It has been widely accepted that respiration is one of the main factors affecting BP measurement. However, little is known about how respiration affects the signals from which BP measurement is obtained. The aim was to quantify the modulation effect of respiration on oscillometric pulses and KorS during clinical BP measurement. Systolic and diastolic BPs were measured manually from 40 healthy subjects (from 23 to 65 years old) under normal and regular deep breathing. The following signals were digitally recorded during linear cuff deflation: chest motion from a magnetometer to obtain reference respiration, cuff pressure from an electronic pressure sensor to derive OscP, and KorS from a digital stethoscope. The effects of respiration on both OscP and KorS were determined from changes in their amplitude associated with respiration between systole and diastole. These changes were normalized to the mean signal amplitude of OscP and KorS to derive the respiratory modulation depth. Reference respiration frequency, and the frequencies derived from the amplitude modulation of OscP and KorS were also calculated and compared. Respiratory modulation depth was 14 and 40 % for OscP and KorS respectively under normal breathing condition, with significant increases (both p < 0.05) to 16 and 49 % with deeper breathing. There was no statistically significant difference between the reference respiration frequency and those derived from the oscillometric and Korotkoff signals (both p > 0.05) during deep breathing, and for the oscillometric signal during normal breathing (p > 0.05). Our study confirmed and quantified the respiratory modulation effect on the oscillometric pulses and KorS during clinical BP measurement, with increased modulation depth under regular deeper breathing.

  4. Identification of a Very High Cuff Pressure by Manual Palpation of the External Cuff Balloon on an Endotracheal Tube.

    PubMed

    Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra

    2015-06-01

    The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.

  5. An underwater blood pressure measuring device.

    PubMed

    Sieber, Arne; Kuch, Benjamin; L'abbate, Antonio; Wagner, Matthias; Dario, Paolo; Bedini, Remo

    2008-09-01

    Measurement of arterial blood pressure is an important vital sign for monitoring the circulation. However, up to now no instrument has been available that enables the measurement of blood pressure underwater. The present paper details a novel, oscillometric, automatic digital blood pressure (BP) measurement device especially designed for this purpose. It consists mainly of analogue and digital electronics in a lexan housing that is rated to a depth of up to 200 metres' sea water, a cuff and a solenoid for inflation of the cuff with air supplied from a scuba tank. An integrated differential pressure sensor, exposed to the same ambient pressure as the cuff, allows accurate BP measurement. Calculation of systolic and diastolic pressures is based on the analysis of pressure oscillations recorded during the deflation. In hyperbaric chamber tests to pressures up to 405 kPa, BP measurements taken with the prototype were comparable to those obtained with established manual and automated methods. Swimming pool tests confirmed the correct functioning of the system underwater. The quality of the recorded pressure oscillations was very good even at 10 metres' fresh water, and allowed determination of diastolic and systolic pressure values. Based on these results we envisage that this device will lead to a better understanding of human cardiovascular physiology in underwater and hyperbaric environments.

  6. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure.

    PubMed

    Climie, Rachel E D; Schultz, Martin G; Nikolic, Sonja B; Ahuja, Kiran D K; Fell, James W; Sharman, James E

    2012-04-01

    Noninvasive central blood pressure (BP) independently predicts mortality, but current methods are operator-dependent, requiring skill to obtain quality recordings. The aims of this study were first, to determine the validity of an automatic, upper arm oscillometric cuff method for estimating central BP (O(CBP)) by comparison with the noninvasive reference standard of radial tonometry (T(CBP)). Second, we determined the intratest and intertest reliability of O(CBP). To assess validity, central BP was estimated by O(CBP) (Pulsecor R6.5B monitor) and compared with T(CBP) (SphygmoCor) in 47 participants free from cardiovascular disease (aged 57 ± 9 years) in supine, seated, and standing positions. Brachial mean arterial pressure (MAP) and diastolic BP (DBP) from the O(CBP) device were used to calibrate in both devices. Duplicate measures were recorded in each position on the same day to assess intratest reliability, and participants returned within 10 ± 7 days for repeat measurements to assess intertest reliability. There was a strong intraclass correlation (ICC = 0.987, P < 0.001) and small mean difference (1.2 ± 2.2 mm Hg) for central systolic BP (SBP) determined by O(CBP) compared with T(CBP). Ninety-six percent of all comparisons (n = 495 acceptable recordings) were within 5 mm Hg. With respect to reliability, there were strong correlations but higher limits of agreement for the intratest (ICC = 0.975, P < 0.001, mean difference 0.6 ± 4.5 mm Hg) and intertest (ICC = 0.895, P < 0.001, mean difference 4.3 ± 8.0 mm Hg) comparisons. Estimation of central SBP using cuff oscillometry is comparable to radial tonometry and has good reproducibility. As a noninvasive, relatively operator-independent method, O(CBP) may be as useful as T(CBP) for estimating central BP in clinical practice.

  7. Cuff filling volumes for pediatric classic laryngeal mask airways: comparison of clinical end points versus adjusted cuff pressure.

    PubMed

    Ghai, Babita; Sethi, Sameer; Ram, Jagat; Wig, Jyotsna

    2013-02-01

    Clinical end points are often used to guide inflation and adequacy of cuff seal after laryngeal mask airway placement. However, clinical end points for cuff inflation have been shown to have significantly higher intracuff pressure. The adjusted cuff pressure between 55 and 60 cm H(2)O causes significantly better seal of laryngeal mask airway. We prospectively assessed the cuff pressures generated by cuff inflation guided by clinical end points, and the actual volume of air required to achieve cuff pressures between 55 and 60 cm H(2)O for sizes 1-2.5 reusable classic laryngeal mask airway. Two hundred and three ASA I and II children undergoing elective cataract surgery requiring general anesthesia receiving laryngeal mask airway sizes 1-2.5 were recruited to this study. The laryngeal mask airway was placed using standard technique. After insertion of laryngeal mask airway, the cuff was slowly inflated until a slight outward shift of device was noted. Cuff pressures were measured using calibrated hand held Portex Cuff Inflator Pressure Gauge (Portex Limited, Hythe, Kent, UK). If the cuff pressure was >60 cm H(2)O, the cuff was deflated to achieve a cuff pressure of 55-60 cm H(2)O. The volume of air required to achieve this pressure was recorded. The volume of air required to achieve the pressure between 55 and 60 cm H(2)O in laryngeal mask airway size 1, 1.5, 2.0, and 2.5 were 2.750 ± 0.2565, 4.951 ± 0.5378, 6.927 ± 0.6328, and 10.208 ± 1.4535 ml, respectively. The difference between the initial and the final cuff volumes and pressures in all laryngeal mask airway sizes were statistically significant(P = 0.000). Lower cuff volumes are required to achieve a pressure of 60 cm H(2)O than those required if clinical end points are used as a sole guide for determining cuff inflation for patients receiving pediatric laryngeal mask airways. © 2012 Blackwell Publishing Ltd.

  8. Relationship of ABO Blood Type on Rotator Cuff Tears.

    PubMed

    Lee, Doo-Hyung; Lee, Han-Dong; Yoon, Seung-Hyun

    2015-11-01

    ABO blood groups are associated with various diseases. A relationship between Achilles tendon ruptures and blood type O has been reported, although its pathogenesis was not clear. To the best of our knowledge, there is no published study describing the relationship between blood type and rotator cuff tendon tears. To determine whether patients with rotator cuff tear had a greater prevalence of blood type O than those without rotator cuff tear. A cross-sectional study. Research hospital outpatient evaluation. A total of 316 subjects with shoulder pain were included and divided into "tear" and "no-tear" groups according to ultrasonographic examination. ABO blood group, gender, dominant arm, smoking history, trauma history, and age were compared between the 2 groups and the odds ratios of these factors were evaluated by logistic regression. The tear group (38.6%) had more instances of blood type O than the healthy population (27.2%; P = .002). The adjusted odds ratio for rotator cuff tear for blood type O to non-O was 2.38 (95% confidence interval 1.28-4.42). The odds ratios for rotator cuff tears for smoking, major trauma history, minor trauma history, and age were 2.08, 3.11, 2.29, and 1.06, respectively. Patients with rotator cuff tears were more likely to have blood type O. The odds ratios of factors for rotator cuff tears were high in the following order: major trauma history, blood type O, minor trauma history, and age. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  9. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    PubMed

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P<0.05) was lower in the group ≤26 cm than in the group >26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  10. [Influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge].

    PubMed

    Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong

    2017-01-01

    To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the

  11. Smart blood pressure holter.

    PubMed

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  12. The effect of cuff presence and cuff inflation on airway pressure in a canine tracheostomy tube model.

    PubMed

    Wignall, Jamie R; Baines, Stephen J

    2014-01-01

    To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.

  13. Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS.

    PubMed

    Weisberg, Stacy N; McCall, Jonathan C; Tennyson, Joseph

    2017-06-01

    Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH 2 O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH 2 O. Maximum altitude for the program ranged from 1,000-3,000 feet above sea level, with a change in altitude from 800-2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH 2 O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs.

  14. Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS

    PubMed Central

    Weisberg, Stacy N.; McCall, Jonathan C.; Tennyson, Joseph

    2017-01-01

    Introduction Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. Methods ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH2O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. Results We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH2O. Maximum altitude for the program ranged from 1,000–3,000 feet above sea level, with a change in altitude from 800–2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH2O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Conclusion Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs. PMID:28611883

  15. Intraoperative Endotracheal Cuff Pressure Study: How Education and Availability of Manometers Help Guide Safer Pressures.

    PubMed

    Stevens, Gregory J; Warfel, Joel W; Aden, James K; Blackwell, Scott D

    2018-02-13

    Endotracheal intubation is a medical procedure that is often indicated in both the perioperative and critical care environments. Cuffed endotracheal tubes (ETT) allow for safer and more efficient delivery of positive pressure ventilation, as well as create a barrier to reduce the risk of micro-aspiration and anesthetic pollution in the operating room environment. Over-inflation of the endotracheal cuff can lead to serious and harmful sequelae. This study aimed to assess if departmental education paired with ready access to a manometer to assess cuff pressure would result in an improvement in the proportion of ETT cuff pressures in the goal range. A quality improvement study was conducted at the San Antonio Military Medical Center (SAMMC; Department of Defense hospital in San Antonio, TX). The initiative was divided into three key periods: pre-implementation, implementation, and post-implementation. During the pre-implementation period, ETT cuff pressures were obtained to assess the baseline state of ETT cuff pressures for patients in the operating room; the proportion of in-range (20-30 cmH2O) pressures was calculated. During the implementation phase, operating rooms were equipped with manometers and anesthesia departmental education was performed regarding the use of the manometers. Three months later, post-implementation cuff pressures were measured in the OR, and the proportion of in-range pressures was again calculated. The pre-implementation data showed an average cuff pressure of 48.92 cmH2O and a median of 38.5 cmH2O. Of the 100 pre-implementation pressures, 20 were in the goal range. Post-implementation data had an average cuff pressure of 41.96 cmH2O and a median of 30 cmH2O. A chi-squared test of pressures in the safe range from the pre-implementation versus post-implementation values yielded a highly significant p-value of 0.0003. The data from this study clearly demonstrated a statistically significant improvement in the proportion of in-range cuff

  16. Student Nurses' Knowledge in Relation to Blood Pressure Measurement by Sphygmomanometry and Auscultation.

    ERIC Educational Resources Information Center

    Torrance, Colin; Serginson, Eve

    1996-01-01

    British nursing students (78 of 93) completed a questionnaire about blood pressure; 90% were not familiar with Korotkoff sounds or auscultary gap; most thought blood pressure was the same in both arms; 63% knew resting was essential before measurement; 59% assessed the arm for cuff size; only 25% thought the cuff should be placed at heart level.…

  17. Endotracheal cuff pressure changes with change in position in neurosurgical patients.

    PubMed

    Athiraman, UmeshKumar; Gupta, Rohit; Singh, Georgene

    2015-01-01

    Placement of a cuffed endotracheal tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent micro-aspiration. Over inflation of the cuff can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. Inadequate seal can lead to micro aspiration. So the cuff pressure has to be monitored and kept within the prescribed limits of 20-30 cms of water. To observe the effect of different positions on the endotracheal cuff pressure in patients undergoing neurosurgical procedures. This is an observational study conducted on 70 patients undergoing neurosurgical procedures in various positions. After intubation, the cuff pressure was checked with a cuff pressure manometer, Endotest (Teleflex Medical, Rush) and adjusted to be within the allowable pressure limits as is the routine practice. The cuff pressure was checked again at three time points after achieving the final position with the head on pins, at the end of the procedure and before extubation. Various factors such as the age, position, duration of surgery were studied. There were no major complications like aspiration, stridor or hoarseness of voice post extubation in any of the patients. A significant decline in the cuff pressures were noted from the initial supine position to extubation (P < .001) in the supine group. Also a significant decline in the cuff pressures were found in the prone group from their initial intubated supine position to all the other three corresponding time points namely after final positioning (P < .001), at the end of the procedure (P < .001) and before extubation (P < .001). Cuff pressure has to be checked after achieving the final positioning of the patient and adjusted to the prescribed limits to prevent micro aspiration.

  18. Effects of Increasing Airway Pressures on the Pressure of the Endotracheal Tube Cuff During Pelvic Laparoscopic Surgery.

    PubMed

    Rosero, Eric B; Ozayar, Esra; Eslava-Schmalbach, Javier; Minhajuddin, Abu; Joshi, Girish P

    2017-11-17

    Tracheal tube cuff pressures exceeding the perfusion pressures of the tracheal mucosa have been associated with complications such as sore throat, tracheal mucosa ulcers, tracheal rupture, and subglottic stenosis. Despite appropriate inflation, many factors can increase the tracheal cuff pressure during mechanical ventilation. This prospective observational cohort study was designed to test the hypothesis that during a clinical model of decreasing respiratory compliance, the pressure within the endotracheal tube cuff will rise in direct relationship to increases in the airway pressures. Twenty-eight adult obese patients (BMI ≥30 kg/m) scheduled for elective laparoscopic gynecologic procedures were enrolled. All patients received general anesthesia utilizing endotracheal tubes with low-pressure high-volume cuffs. After baseline adjustment of the cuff pressure to 25 cm H2O, the airway pressures and endotracheal cuff pressures were continuously measured using pressure transducers connected to the anesthesia circuit and cuff pilot, respectively. Data on cuff and airway pressures, mechanical ventilation parameters, intraabdominal pressures, and degree of surgical table inclination were collected throughout the anesthetic procedure. General linear regression models with fixed and random effects were fit to assess the effect of increases in airway pressures on cuff pressure, after adjusting for covariates and the clustered structure of the data. The mean (standard deviation) age and body mass index were 42.2 (8.8) years and 37.7 (5.1) kg/m, respectively. After tracheal intubation, the cuffs were overinflated (ie, intracuff pressures >30 cm H2O) in 89% of patients. The cuff pressures significantly changed after concomitant variations in the airway pressures from a mean (standard error) value of 29.6 (1.30) cm H2O before peritoneal insufflations, to 35.6 (0.68) cm H2O after peritoneal insufflation, and to 27.8 (0.79) cm H2O after peritoneal deflation (P < .0001). The

  19. Special report: Occlusive cuff controller

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1975-01-01

    A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

  20. Comparison of endotracheal tube cuff pressure values before and after training seminar.

    PubMed

    Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa

    2018-06-01

    It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p < 0.001). Average pressure measure for Group I was 54 cm H 2 O, while average pressure in Group II declined to 33 cm H 2 O. It was observed that as the working period and experience of physician assistants increased, cuff pressure values decreased, however no statistically significant different was found (p < 0.375). We believe that clinical experience does not have significant effects on cuff pressure and that training seminars held at intervals would prevent high cuff pressure values and potential complications.

  1. Managing endotracheal tube cuff pressure at altitude: a comparison of four methods.

    PubMed

    Britton, Tyler; Blakeman, Thomas C; Eggert, John; Rodriquez, Dario; Ortiz, Heather; Branson, Richard D

    2014-09-01

    Ascent to altitude results in the expansion of gases in closed spaces. The management of overinflation of the endotracheal tube (ETT) cuff at altitude is critical to prevent mucosal injury. We continuously measured ETT cuff pressures during a Critical Care Air Transport Team training flight to 8,000-ft cabin pressure using four methods of cuff pressure management. ETTs were placed in a tracheal model, and mechanical ventilation was performed. In the control ETT, the cuff was inflated to 20 mm Hg to 22 mm Hg and not manipulated. The manual method used a pressure manometer to adjust pressure at cruising altitude and after landing. A PressureEasy device was connected to the pilot balloon of the third tube and set to a pressure of 20 mm Hg to 22 mm Hg. The final method filled the balloon with 10 mL of saline. Both size 8.0-mm and 7.5-mm ETT were studied during three flights. In the control tube, pressure exceeded 70 mm Hg at cruising altitude. Manual management corrected for pressure at altitude but resulted in low cuff pressures upon landing (<10 mm Hg). The PressureEasy reduced the pressure change to a maximum of 36 mm Hg, but on landing, cuff pressures were less than 15 mm Hg. Saline inflation ameliorated cuff pressure changes at altitude, but initial pressures were 40 mm Hg. None of the three methods using air inflation managed to maintain cuff pressures below those associated with tracheal damage at altitude or above pressures associated with secretion aspiration during descent. Saline inflation minimizes altitude-related alteration in cuff pressure but creates excessive pressures at sea level. New techniques need to be developed.

  2. Cuffless Blood Pressure Estimation Based on Data-Oriented Continuous Health Monitoring System

    PubMed Central

    Kawanaka, Haruki; Oguri, Koji

    2017-01-01

    Measuring blood pressure continuously helps monitor health and also prevent lifestyle related diseases to extend the expectancy of healthy life. Blood pressure, which is nowadays used for monitoring patient, is one of the most useful indexes for prevention of lifestyle related diseases such as hypertension. However, continuously monitoring the blood pressure is unrealistic because of discomfort caused by the tightening of a cuff belt. We have earlier researched the data-oriented blood pressure estimation without using a cuff. Remarkably, our blood pressure estimation method only uses a photoplethysmograph sensor. Therefore, the application is flexible for sensor locations and measuring situations. In this paper, we describe the implementation of our estimation method, the launch of a cloud system which can collect and manage blood pressure data measured by a wristwatch-type photoplethysmograph sensor, and the construction of our applications to visualize life-log data including the time-series data of blood pressure. PMID:28523074

  3. Improved Measurement of Blood Pressure by Extraction of Characteristic Features from the Cuff Oscillometric Waveform

    PubMed Central

    Lim, Pooi Khoon; Ng, Siew-Cheok; Jassim, Wissam A.; Redmond, Stephen J.; Zilany, Mohammad; Avolio, Alberto; Lim, Einly; Tan, Maw Pin; Lovell, Nigel H.

    2015-01-01

    We present a novel approach to improve the estimation of systolic (SBP) and diastolic blood pressure (DBP) from oscillometric waveform data using variable characteristic ratios between SBP and DBP with mean arterial pressure (MAP). This was verified in 25 healthy subjects, aged 28 ± 5 years. The multiple linear regression (MLR) and support vector regression (SVR) models were used to examine the relationship between the SBP and the DBP ratio with ten features extracted from the oscillometric waveform envelope (OWE). An automatic algorithm based on relative changes in the cuff pressure and neighbouring oscillometric pulses was proposed to remove outlier points caused by movement artifacts. Substantial reduction in the mean and standard deviation of the blood pressure estimation errors were obtained upon artifact removal. Using the sequential forward floating selection (SFFS) approach, we were able to achieve a significant reduction in the mean and standard deviation of differences between the estimated SBP values and the reference scoring (MLR: mean ± SD = −0.3 ± 5.8 mmHg; SVR and −0.6 ± 5.4 mmHg) with only two features, i.e., Ratio2 and Area3, as compared to the conventional maximum amplitude algorithm (MAA) method (mean ± SD = −1.6 ± 8.6 mmHg). Comparing the performance of both MLR and SVR models, our results showed that the MLR model was able to achieve comparable performance to that of the SVR model despite its simplicity. PMID:26087370

  4. Tracheal tube cuff inflation guided by pressure volume loop closure associated with lower postoperative cuff-related complications: Prospective, randomized clinical trial.

    PubMed

    Almarakbi, Waleed A; Kaki, Abdullah M

    2014-07-01

    The main function of an endotracheal tube (ETT) cuff is to prevent aspiration. High cuff pressure is usually associated with postoperative complications. We tried to compare cuff inflation guided by pressure volume loop closure (PV-L) with those by just to seal technique (JS) and assess the postoperative incidence of sore throat, cough and hoarseness. In a prospective, randomized clinical trial, 100 patients' tracheas were intubated. In the first group (n = 50), ETT cuff inflation was guided by PV-L, while in the second group (n. = 50) the ETT cuff was inflated using the JS technique. Intracuff pressures and volumes were measured. The incidence of postoperative cuff-related complications was reported. Demographic data and durations of intubation were comparable between the groups. The use of PV-L was associated with a lesser amount of intracuff air [4.05 (3.7-4.5) vs 5 (4.8-5.5), P < 0.001] and lower cuff pressure than those in the JS group [18.25 (18-19) vs 33 (32-35), P ≤ 0.001]. The incidence of postextubation cuff-related complications was significantly less frequent among the PV-L group patients as compared with the JS group patients (P ≤ 0.009), except for hoarseness of voice, which was less frequent among the PV-L group, but not statistically significant (P ≤ 0.065). Multiple regression models for prediction of intra-cuff pressure after intubation and before extubation revealed a statistically significant association with the technique used for cuff inflation (P < 0.0001). The study confirms that PV-L-guided ETT cuff inflation is an effective way to seal the airway and associates with a lower ETT cuff pressure and lower incidence of cuff-related complications.

  5. Measurement of carotid blood pressure and local pulse wave velocity changes during cuff induced hyperemia.

    PubMed

    Nabeel, P M; Karthik, Srinivasa; Joseph, Jayaraj; Sivaprakasam, Mohanasankar

    2017-07-01

    We present a prototype design of dual element photoplethysmograph (PPG) probe along with associated measurement system for carotid local pulse wave velocity (PWV) evaluation in a non-invasive and continuous manner. The PPG probe consists of two identical sensing modules placed 23 mm apart. Simultaneously measured blood pulse waveforms from these arterial sites were processed and the pulse transit time delay was resolved using the developed application-specific software. The ability of developed PPG probe and associated measurement system to detect acute changes in carotid local PWV due to blood pressure (BP) variations was experimentally validated by an in-vivo study. Intra-subject carotid BP elevation was achieved by an upper arm cuff based occlusion, which offered a controlled way of local PWV escalation. The elevated carotid BP values were also recorded by a calibrated pressure tonometer prior to the study, and was used as a reference. A significant increment (1.0 - 2.6 m/s) in local PWV was observed and was proportional to the BP increment induced by the occlusive reactive hyperemia. Study results demonstrated the feasibility of real-time signal acquisition and reliable local PWV evaluation under normal and elevated BP conditions using the developed measurement system.

  6. Comparison of Different Cuff Pressure Use with the Supreme Laryngeal Mask Airway on Haemodynamic Response, Seal Pressure and Postoperative Adverse Events: A Prospective Randomized Study.

    PubMed

    Ali, Achmet; Altun, Demet; Sivrikoz, Nukhet; Yornuk, Mesut; Turgut, Namigar; Akıncı, İbrahim Özkan

    2018-04-01

    The Supreme™ laryngeal mask airway (SLMA) is a supra glottic airway (SGA) device that is used as an alternative to endotracheal tubes. In the present study, we aimed to compare the use of the SLMA with normal cuff pressure and low cuff pressure, primarily for haemodynamic response. In the present study, 120 patients diagnosed with hypertension and scheduled for varicose vein or inguinal hernia operation were enrolled and 99 patients finished. Using randomization, patients were divided into two groups according to cuff pressure as a low-pressure group (Group L, 45 cm H 2 O) and a normal-pressure group (Group N, 60 cm H 2 O). Demographics, Mallampati score and the type and duration of surgery, heart rate (HR), mean arterial pressure (MAP), percentage of tidal volume leakage, Ppeak, Pmean, etCO 2 , seal pressure, fibreoptic scores and postoperative adverse effects of all patients were recorded. MAP and HR values immediately and 2 minutes after SLMA insertion were significantly lower in Group L (p<0.001). In Group L and Group N, the seal pressures were 24.1±3.1 cm H 2 O and 26.2±3.9 cm H 2 O, respectively (p=0.003). Also, blood staining and sore throat occurred less frequently in Group L (p<0.05). The fibreoptic average score, insertion features and ventilation parameters were similar between the groups (p>0.05). SLMA use with a cuff pressure of 45 cm H 2 O significantly decreases haemodynamic response and post-operative side effects compared with a normal cuff pressure. Therefore, except for some specific surgeries that require higher seal pressures, we recommend the use of the SLMA with cuff pressures as low as 45 cm H 2 O.

  7. Comparison of Pressure Changes by Head and Neck Position between High-Volume Low-Pressure and Taper-Shaped Cuffs: A Randomized Controlled Trial

    PubMed Central

    Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki

    2015-01-01

    The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152

  8. How Does Circadian Rhythm Impact Salt Sensitivity of Blood Pressure in Mice? A Study in Two Close C57Bl/6 Substrains.

    PubMed

    Combe, Roy; Mudgett, John; El Fertak, Lahcen; Champy, Marie-France; Ayme-Dietrich, Estelle; Petit-Demoulière, Benoit; Sorg, Tania; Herault, Yann; Madwed, Jeffrey B; Monassier, Laurent

    2016-01-01

    Mouse transgenesis has provided the unique opportunity to investigate mechanisms underlying sodium kidney reabsorption as well as end organ damage. However, understanding mouse background and the experimental conditions effects on phenotypic readouts of engineered mouse lines such as blood pressure presents a challenge. Despite the ability to generate high sodium and chloride plasma levels during high-salt diet, observed changes in blood pressure are not consistent between wild-type background strains and studies. The present work was designed in an attempt to determine guidelines in the field of salt-induced hypertension by recording continuously blood pressure by telemetry in mice submitted to different sodium and potassium loaded diets and changing experimental conditions in both C57BL/6N and C57BL/6J mice strain (Normal salt vs. Low salt vs. High-salt/normal potassium vs. High salt/low potassium, standard vs. modified light cycle, Non-invasive tail cuff blood pressure vs. telemetry). In this study, we have shown that, despite a strong blood pressure (BP) basal difference between C57BL/6N and C57BL/6J mice, High salt/normal potassium diet increases BP and heart rate during the active phase only (dark period) in the same extent in both strains. On the other hand, while potassium level has no effect on salt-induced hypertension in C57BL/6N mice, high-salt/low potassium diet amplifies the effect of the high-salt challenge only in C57BL/6J mice. Indeed, in this condition, salt-induced hypertension can also be detected during light period even though this BP increase is lower compared to the one occurring during the dark period. Finally, from a methodological perspective, light cycle inversion has no effect on this circadian BP phenotype and tail-cuff method is less sensitive than telemetry to detect BP phenotypes due to salt challenges. Therefore, to carry investigations on salt-induced hypertension in mice, chronic telemetry and studies in the active phase are

  9. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    PubMed Central

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval −3.5 to −2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  10. Noninvasive and continuous blood pressure measurement via superficial temporal artery tonometry.

    PubMed

    Canning, Julia; Helbert, Kendall; Iashin, Grigoriy; Matthews, Jonathan; Yang, Jason; Delano, Margaret K; Sodini, Charles G; Quan Zhang

    2016-08-01

    The measurement of blood pressure is an important cardiovascular health assessment, yet the current set of methodologies is limited in resolution, repeatability, accuracy, simplicity, and safety. This paper presents the design and prototype implementation of a novel and easy-to-use medical device for noninvasive and continuous blood pressure monitoring through tonometry at the superficial temporal artery (STA). The device features a stable form factor inspired by over-ear headphones that adjusts easily from person to person using a combination prismatic and rotational joint. A stepper motor and pressure sensor, built into the device, apply a controlled force to flatten the artery and measure the wearer's blood pressure. The design is fully wireless, using Bluetooth communication to connect to a custom control and monitoring interface on the user's laptop that allows for easy calibration and real-time measurement. Preliminary testing of the device showed a percentage error from a blood pressure cuff mean arterial pressure measurement of 7.7% (7.0 mmHg). This was also compared to a Nexfin vascular unloading device, which showed a percentage error from the blood pressure cuff of 7.3% (6.6 mmHg).

  11. [A design and study of a novel electronic device for cuff-pressure monitoring].

    PubMed

    Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang

    2017-06-01

    To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P

  12. Blood pressure measurement and display system

    NASA Technical Reports Server (NTRS)

    Farkas, A. J.

    1972-01-01

    System is described that employs solid state circuitry to transmit visual display of patient's blood pressure. Response of sphygmomanometer cuff and microphone provide input signals. Signals and their amplitudes, from turn-on time to turn-off time, are continuously fed to data transmitter which transmits to display device.

  13. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    PubMed

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  14. Sleep deprivation increases blood pressure in healthy normotensive elderly and attenuates the blood pressure response to orthostatic challenge.

    PubMed

    Robillard, Rébecca; Lanfranchi, Paola A; Prince, François; Filipini, Daniel; Carrier, Julie

    2011-03-01

    To determine how aging affects the impact of sleep deprivation on blood pressure at rest and under orthostatic challenge. Subjects underwent a night of sleep and 24.5 h of sleep deprivation in a crossover counterbalanced design. Sleep laboratory. Sixteen healthy normotensive men and women: 8 young adults (mean 24 years [SD 3.1], range 20-28 years) and 8 elderly adults (mean 64.1 years [SD 3.4], range 60-69 years). Sleep deprivation. Brachial cuff arterial blood pressure and heart rate were measured in semi-recumbent and upright positions. These measurements were compared across homeostatic sleep pressure conditions and age groups. Sleep deprivation induced a significant increase in systolic and diastolic blood pressure in elderly but not young adults. Moreover, sleep deprivation attenuated the systolic blood pressure orthostatic response in both age groups. Our results suggest that sleep deprivation alters the regulatory mechanisms of blood pressure and might increase the risk of hypertension in healthy normotensive elderly.

  15. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.

    PubMed

    El Feghali, Ramzi N; Topouchian, Jirar A; Pannier, Bruno M; El Assaad, Hiba A; Asmar, Roland G

    2007-06-01

    A high percentage of hypertensive patients present an arm circumference of over 32 cm; the use of a large cuff is therefore recommended. Validation studies are usually performed in the general population using a standard-size cuff. The aim of this study was to assess the accuracy of the Omron M7 device in a population with an arm circumference ranging from 32 to 42 cm. A validation study was performed according to the International Protocol of the European Society of Hypertension. This protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood-pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood-pressure measurements), making a total number of 33 participants (99 pairs of blood-pressure measurements), on whom the analysis is performed. For each participant, four blood-pressure measurements were performed simultaneously by two trained observers, using mercury sphygmomanometers fitted with a Y tube; the measurements alternated with three by the test device. The difference between the blood-pressure value given by the device and that obtained by the two observers (mean of the two observations) was calculated for each measure. The 99 pairs of blood-pressure differences were classified into three categories (blood pressure and diastolic blood pressure, and those between the device and the mercury sphygmomanometer were -1.6+/-6.7 for systolic blood pressure and -0.12+/-4.0 mmHg for diastolic blood pressure Readings that differ by less than 5, 10 and 15 mmHg for systolic blood-pressure and diastolic blood-pressure

  16. Clinical aviation medicine research : comparison of simultaneous measurements of intra-aortic and auscultatory blood pressures with pressure-flow dynamics during rest and excercise.

    DOT National Transportation Integrated Search

    1966-10-01

    The study provides correlative information with respect to the comparative accuracy of the traditional 'cuff' clinical method of obtaining blood pressure and the laboratory catheterization procedure which measures actual blood pressure. The informati...

  17. A device and method for rapid indirect measurement of human systolic and diastolic blood pressures.

    DOT National Transportation Integrated Search

    1970-12-01

    An indirect blood pressure measuring device and method were evolved for human use. This system is capable of providing 30 measurements each of systolic and diastolic pressures per minute. The system utilizes two brachial blood pressure cuffs (one on ...

  18. Effects of S-1-propenylcysteine, a sulfur compound in aged garlic extract, on blood pressure and peripheral circulation in spontaneously hypertensive rats.

    PubMed

    Ushijima, Mitsuyasu; Takashima, Miyuki; Kunimura, Kayo; Kodera, Yukihiro; Morihara, Naoaki; Tamura, Koichi

    2018-04-01

    This study was designed to investigate the antihypertensive effect of S-1-propenylcysteine, a characteristic sulfur compound in aged garlic extract, using a hypertensive rat model. The blood pressure and tail blood flow of both spontaneously hypertensive rats and control Wistar Kyoto rats were measured by the tail-cuff method and the noncontact laser Doppler method, respectively, at various times after single oral administration of a test compound for 24 h. Treatment with S-1-propenylcysteine (6.5 mg/kg BW) significantly decreased the systolic blood pressure of spontaneously hypertensive rat approximately 10% at 3 h after administration, and thereafter, the systolic blood pressure gradually returned to the baseline level in 24 h. The effect of S-1-propenylcysteine was dose-dependent and was maximal at the dose of 6.5 mg/kg BW at 3 h. However, the other compounds such as S-allylcysteine and S-allylmercaptocysteine in aged garlic extract were ineffective. In addition, S-1-propenylcysteine had no effect on systolic blood pressure of control Wistar Kyoto rats. Furthermore, S-1-propenylcysteine significantly increased the blood flow at 3 h after administration at the dose of 6.5 mg/kg BW. S-1-propenylcysteine is a key constituent of aged garlic extract responsible for its antihypertensive effect, and the effect of S-1-propenylcysteine involves the improvement in peripheral circulation. © 2018 Royal Pharmaceutical Society.

  19. Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maltz, Jonathan S.

    Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal ismore » not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.« less

  20. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    PubMed

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  1. Pressure ramp programmer; IMBLMS Phase B4 Additional Tasks: Task 3.0 pressure ramp programmer

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Reinhardt, C. G.

    1972-01-01

    A pressure ramp programmer model was designed, fabricated and tested. This model, in conjunction with an automatic blood pressure monitor, automatically controls the pressure in the blood pressure monitor arterial cuff. The cuff pressurization cycle is designed to maximize accuracy and repeatability of blood pressure measurements. The key feature of this automatic cycle is rapid blood pressure cuff bleed down from an initial setting until systolic (diastolic) pressure is encountered followed by a short repressurization and slow bleed, long enough to permit accurate systolic (diastolic) pressure determination. The system includes a pressure reservoir which bleeds the cuff through a precision needle valve; a solenoid valve which permits rapid pressurization from the reservoir; and a pressure sensor which provides information for bleed rate and set point controls. Korotkoff sound signals from a microphone in the blood pressure cuff (not part of the system) provide decision information to the digital control system. The system completed a series of engineering tests using simulated Korotkoff sound inputs. The system performed successfully in all cases and was stable over an extended period of time.

  2. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    PubMed

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval -3.5 to -2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  3. Comparison of the autoregulatory mechanisms between middle cerebral artery and ophthalmic artery after thigh cuff deflation in healthy subjects.

    PubMed

    Kolodjaschna, Julia; Berisha, Fatmire; Lung, Solveig; Schima, Heinrich; Polska, Elzbieta; Schmetterer, Leopold

    2005-02-01

    To compare dynamic autoregulation in the middle cerebral artery (MCA) and the ophthalmic artery (OA) after a step decrease in systemic blood pressure. Eighteen healthy male young subjects were studied. Ultrasound parameters and systemic blood pressures were recorded in each subject before, during, and after a step decrease in blood pressure. Continuous blood pressure recordings were made with a finger plethysmograph system, and flow velocities in the MCA and the OA were continuously measured with Doppler ultrasound. Large bilateral thigh cuffs were inflated and a pressure approximately 20 mm Hg above peak systolic blood pressure was maintained for 3 minutes. A decrease in blood pressure was induced by rapid deflation of bilateral thigh cuffs. Experiments were performed separately for the OA and the MCA. Systemic blood pressure showed a step decrease immediately after thigh cuff release (9%-15%) and returned to baseline 7 to 10 pulse cycles later. Flow velocities in the MCA returned to baseline earlier than systemic blood pressure, indicating peripheral vasodilatation, with a maximum of five to six pulse cycles after the blood pressure decrease. By contrast, flow velocities in the OA returned to baseline later than systemic blood pressure, reflecting peripheral vasoconstriction with a maximum 10 to 15 pulse cycles after cuff release. There was a statistically significant difference in the time course of the resistance changes in the two selected arteries after thigh cuff release (P < 0.001). The results of the present study suggest substantial differences in the autoregulatory behavior of the vascular beds peripheral to the MCA and the OA. Results in the MCA would be compatible with either metabolic or myogenic vasodilatation, whereas the results in the OA could reflect sympathetic vasoconstriction. Further studies are needed to support this hypothesis. The thigh cuff technique may represent an interesting approach to the study of autoregulation in patients with

  4. [Cuff pressure control at the intersinve care unit: influence of nursing professionals' training].

    PubMed

    Velasco Sanz, T R; Ronda Delgado de la Fuente, M; Sánchez de la Ventana, A B; Reyes Merino Martínez, M

    2015-01-01

    To analyze proper control of endotracheal cuff pressure in an intensive care unit. The specific objective is to verify whether training of nursing professionals improves monitoring endotracheal cuff pressure. the study type is descriptive, observational and retrospective. All patients were admitted to the Critical Unit II of the Clínico San Carlos Hospital between May 2010-November 2011, requiring either a tracheal tube or tracheal cannula. Studied variables were: number of in range measures, number of intubated patients, or with tracheal cannula and register. Four cuts were made on all admitted patients admitted during the study period in order to measure endotracheal cuff pressure. Two cuts were performed before the professional nurses training and the other two cuts after a specific training with respect to endotracheal cuff pressure and Zero pneumonia. There were 74 measurements. The first cut obtained 40.74% of measures in range. In the second cut 61.90% of measures were identified in range. In the third cut, it was found that 85.7% of measures were in range and in the fourth court, it was noted the 89.47% of measures were in range. Monitoring of the endotracheal cuff pressure was inadequate before specific training of professionals. Nursing professionals training facilitates the correct measurement of the endotracheal cuff pressure, which improves patient safety. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  5. Involvement of Inflammation and Adverse Vascular Remodelling in the Blood Pressure Raising Effect of Repeatedly Heated Palm Oil in Rats

    PubMed Central

    Ng, Chun-Yi; Kamisah, Yusof; Faizah, Othman; Jubri, Zakiah; Qodriyah, Hj Mohd Saad; Jaarin, Kamsiah

    2012-01-01

    Oil thermoxidation during deep frying generates harmful oxidative free radicals that induce inflammation and increase the risk of hypertension. This study aimed to investigate the effect of repeatedly heated palm oil on blood pressure, aortic morphometry, and vascular cell adhesion molecule-1 (VCAM-1) expression in rats. Male Sprague-Dawley rats were divided into five groups: control, fresh palm oil (FPO), one-time-heated palm oil (1HPO), five-time-heated palm oil (5HPO), or ten-time-heated palm oil (10HPO). Feeding duration was six months. Blood pressure was measured at baseline and monthly using tail-cuff method. After six months, the rats were sacrificed and the aortic arches were dissected for morphometric and immunohistochemical analyses. FPO group showed significantly lower blood pressure than all other groups. Blood pressure was increased significantly in 5HPO and 10HPO groups. The aortae of 5HPO and 10HPO groups showed significantly increased thickness and area of intima-media, circumferential wall tension, and VCAM-1 than other groups. Elastic lamellae were disorganised and fragmented in 5HPO- and 10HPO-treated rats. VCAM-1 expression showed a significant positive correlation with blood pressure. In conclusion, prolonged consumption of repeatedly heated palm oil causes blood pressure elevation, adverse remodelling, and increased VCAM-1, which suggests a possible involvement of inflammation. PMID:22778962

  6. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    PubMed

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  7. Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time.

    PubMed

    Xiang, Haiyan; Liu, Yanyong; Li, Yinhua; Qin, Yufei; Yu, Mengsun

    2012-02-01

    To propose a novel noninvasive beat-to-beat arterial blood pressure measurement method based on the Korotkoff sound delay time (KDT) and evaluate its accuracy in preliminary experiments. KDT decreases as the cuff pressure P deflates, which can be described by a function KDT=f (P). Actually, KDT is a function of arterial transmural pressure. Therefore, the variation in blood pressure can be obtained by the transmural pressure, which is estimated by the KDT. Holding the cuff pressure at an approximate constant pressure between systolic pressure and diastolic pressure, the variation in blood pressure ΔEBP between successive heartbeats can be estimated according to KDT and f'(p), which represents the variation of KDT corresponding to unit pressure. Then the blood pressure for each heartbeat can be obtained by accumulating the ΔEBP. Invasive and noninvasive blood pressure values of six participants were measured simultaneously to evaluate the method. The average of the correlation coefficients between the invasive mean arterial pressure (MAP) and the KDT for six participants was -0.91. The average of the correlation coefficients between the invasive MAP and the estimated mean blood pressure (EBP) was 0.92. The mean difference between EBP and MAP was 0.51 mmHg, and the SD was 2.65 mmHg. The mean blood pressure estimated by the KDT is consistent with the invasive MAP. The beat-to-beat blood pressure estimated by KDT provides an accurate estimate of MAP in the preliminary experiments and represents a potential acceptable alternative to invasive blood pressure monitoring during laboratory studies.

  8. Embedded programmable blood pressure monitoring system

    NASA Astrophysics Data System (ADS)

    Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk

    2010-02-01

    A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.

  9. User-independent assessment of conditioning pain modulation by cuff pressure algometry.

    PubMed

    Graven-Nielsen, T; Izumi, M; Petersen, K K; Arendt-Nielsen, L

    2017-03-01

    The use of conditioning pain modulation (CPM) is hampered by poor reproducibility and lack of user-independent paradigms. This study refined the CPM paradigm by applying user-independent cuff algometry. In 20 subjects, the CPM effect of conditioning with cuff stimulation on the arm was investigated by pain test stimuli on the contralateral leg before and in parallel with different cuff conditionings (10, 30, 60 kPa/60 s; 30, 60 kPa/10 s). As test stimulus, another cuff was inflated (1 kPa/s) until the subjects detected the pain tolerance threshold (PTT) during which the pain detection threshold (PDT) and the pressure at a pain intensity of 6 cm on a 10-cm visual analogue scale (PVAS6) were extracted. For comparison, pressure pain thresholds (PPTs) as test stimuli were recorded by the user-dependent handheld pressure algometry. Combinations of cuff locations for conditioning (pain intensity standardized) and contralateral test stimuli were additionally evaluated (leg-arm, leg-leg, arm-thigh). The test-retest reliability in two sessions 1 month apart was assessed in five CPM protocols. In all protocols, the PDT, PVAS6 and PTT increased during conditioning compared with baseline (p < 0.05). The CPM effect (i.e. conditioning minus baseline) for PVAS6, PTT and PPT increased for increasing conditioning intensities (p < 0.05). The CPM effects were not significantly different for changes in conditioning durations or conditioning/test stimulus locations. In two sessions, the CPM effects for PVAS6 and PTT assessed after 60 s of conditioning on the leg/thigh showed the highest intra-class correlations (0.47-0.73), where they were 0.04-0.6 for PPTs. The user-independent cuff algometry is reliable for CPM assessment and for supra-pain threshold test stimuli better than the user-dependent technology. A user-independent CPM technique where the conditioning is controlled by one cuff stimulation, and the test-stimulus is provided by another cuff stimulation. This study

  10. Postanesthesia patients with large upper arm circumference: is use of an "extra-long" adult cuff or forearm cuff placement accurate?

    PubMed

    Watson, Sheri; Aguas, Marita; Bienapfl, Tracy; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Yosses, Mary Beth; Yu, Larissa; Anastas, Zoe

    2011-06-01

    The purpose of this study was to determine if blood pressure (BP) measured in the forearm or with an extra-long BP cuff in the upper arm accurately reflects BP measured in the upper arm with an appropriately sized BP cuff in patients with large upper arm circumference. A method-comparison design was used with a convenience sample of 49 PACU patients. Noninvasive blood pressures were obtained in two different locations (forearm; upper arm) and in the upper arm with an extra-long adult and recommended large adult cuff sizes. Data were analyzed by calculating bias and precision for the BP cuff size and location and Student's t-tests, with P < .0125 considered significant. Significantly higher forearm systolic (P < .0001) and diastolic (P < .0002) BP measurements were found compared to BP obtained in the upper arm with the reference standard BP cuff. Significantly higher systolic (t(48df) = 5.38, P < .0001), but not diastolic (t(48df) = 4.11, P < .019), BP differences were found for BP measured with the extra-long cuff at the upper arm site compared to the upper arm, reference standard BP. Findings suggest that the clinical practice of using the forearm or an extra-long cuff in the upper arm for BP measurement in post anesthesia patients with large upper arm circumferences may result in inaccurate BP values. Copyright © 2011 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  11. Tracheal cuff pressure monitoring in the ICU: a literature review and survey of current practice in Queensland.

    PubMed

    Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D

    2014-11-01

    The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.

  12. Perivascular fluid cuffs decrease lung compliance by increasing tissue resistance.

    PubMed

    Lowe, Kevin; Alvarez, Diego F; King, Judy A; Stevens, Troy

    2010-06-01

    Lung inflammation causes perivascular fluid cuffs to form around extra-alveolar blood vessels; however, the physiologic consequences of such cuffs remain poorly understood. Herein, we tested the hypothesis that perivascular fluid cuffs, without concomitant alveolar edema, are sufficient to decrease lung compliance. Prospective, randomized, controlled study. Research laboratory. One hundred twenty male CD40 rats. To test this hypothesis, the plant alkaloid thapsigargin was used to activate store-operated calcium entry and increase cytosolic calcium in endothelium. Thapsigargin was infused into a central venous catheter of intact, sedated, and mechanically ventilated rats. Static and dynamic lung mechanics and hemodynamics were measured continuously. Thapsigargin produced perivascular fluid cuffs along extra-alveolar vessels but did not cause alveolar flooding or blood gas abnormalities. Lung compliance dose-dependently decreased after thapsigargin infusion, attributable to an increase in tissue resistance that was attributed to increased tissue damping and tissue elastance. Airway resistance was not changed. Neither central venous pressure nor left ventricular end diastolic pressure was altered by thapsigargin. Heart rate did not change, although thapsigargin decreased left ventricular systolic function sufficient to reduce cardiac output by 50%. Infusion of the type 4 phosphodiesterase inhibitor, rolipram, prevented thapsigargin from inducing perivascular cuffs and decreasing lung compliance. Rolipram also normalized pressure over time and corrected the deficit in cardiac output. Our findings resolve for the first time that perivascular cuff formation negatively impacts mechanical coupling between the bronchovascular bundle and the lung parenchyma, decreasing lung compliance without impacting central venous pressure.

  13. Arm position during ambulatory blood pressure monitoring: a review of the evidence and clinical guidelines.

    PubMed

    Byrd, James B; Brook, Robert D

    2014-03-01

    Ambulatory blood pressure monitoring (ABPM) offers advantages over clinic blood pressure measurement. Supporting the arm at the level of the right atrium has long been standard in clinic blood pressure measurement. In contrast, there is no consensus regarding arm position in the guidelines addressing ABPM. Research studies have used a variety of arm positions during ABPM. Discussed in this review are the merits of ABPM and a review of the several arm positions recommended in ABPM guidelines, suggested by cuff manufacturers, and used in research studies. To address this lack of standardization, a rationale for a clinically reasonable arm position during ABPM is offered. Specifically, the authors recommend advising the patient to keep the arm still and relaxed straight down at the side of the body when the cuff is going to inflate, when safe to do so. ©2014 Wiley Periodicals, Inc.

  14. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review

    PubMed Central

    Holden, John

    2016-01-01

    Objective To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Design Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. Data sources MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Eligibility criteria Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. Results 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2

  15. Noninvasive monitoring of blood pressure using optical Ballistocardiography and Photoplethysmograph approaches.

    PubMed

    Chen, Zhihao; Yang, Xiufeng; Teo, Ju Teng; Ng, Soon Huat

    2013-01-01

    A new all optical method for long term and continuous blood pressure measurement and monitoring without using cuffs is proposed by using Ballistocardiography (BCG) and Photoplethysmograph (PPG). Based on BCG signal and PPG signal, a time delay between these two signals is obtained to calculate both systolic blood pressure and diastolic blood pressure via linear regression analysis. The fabricated noninvasive blood pressure monitoring device consists of a fiber sensor mat to measure BCG signal and a SpO2 sensor to measure PPG signal. A commercial digital oscillometric blood pressure meter is used to obtain reference values and for calibration. It has been found that by comparing with the reference device, our prototype has typical means and standard deviations of 9+/-5.6 mmHg for systolic blood pressure, 1.8+/-1.3 mmHg for diastolic blood pressure and 0.6+/-0.9 bpm for pulse rate, respectively. If the fiber optic SpO2 probe is used, this new all fiber cuffless noninvasive blood pressure monitoring device will truly be a MRI safe blood pressure measurement and monitoring device.

  16. Noninvasive monitoring of systolic blood pressure on the arm utilizing photoplethysmography (PPG): clinical report

    NASA Astrophysics Data System (ADS)

    Laurent, Claes; Jonsson, Bjorn; Vegfors, Magnus; Eneling, Martin; Lindberg, Lars-Goran

    2004-07-01

    A soft (silicone) probe, containing six light emitting diodes (880 nm) and three photo detectors, utilizes photoplethysmography (PPG) to monitor pulsations from the brachialis artery under an occluding cuff during deflation. When the arterial pulse returns, measured by PPG, the corresponding pressure in the cuff is determined. This pressure is assumed to equal the systolic pressure. An assessment trial was performed on 21 patients (9 women and 12 men, aged 27-69) at the Neuro-Intensive care unit. Since the patients were already provided with arterial needles, invasive blood pressure could be used as the reference. By choosing a threshold, for detecting pulses, as a fraction (4%) of the maximum amplitude, the systolic blood pressure was underestimated (-0.57 mmHg, SD 12.1). The range of systolic pressure for the patients was 95.5 - 199.0 mmHg, n=14. The method is promising, but improvements still have to be made in order to improve the technique.

  17. Peripheral vascular effects on auscultatory blood pressure measurement.

    PubMed

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p < 0.3] and diastolic [p < 0.02]). Nevertheless, such alterations were found to modify the amplitude of the Korotkoff sound, which can manifest itself as an apparent change in arterial blood pressure that is readily discerned by the human ear. The increase in diastolic pressure for the cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  18. Automated Control of Endotracheal Tube Cuff Pressure during Simulated Flight

    DTIC Science & Technology

    2016-06-21

    accomplished in the intensive care unit (ICU) with stand-alone devices as well as those integral to a ventilator [13,14]. We hypothesized that closed loop ... Administration approved automatic cuff pressure adjustment devices (Intellicuff, Hamilton Medical , Reno, NV; Pyton, ARM Medical , Bristol, CT; Cuff Sentry, Outcome...711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Int’l Expeditionary Educ & Training Dept Air Force Expeditionary Medical

  19. Automated Control of Endotracheal Tube Cuff Pressure During Simulated Flight

    DTIC Science & Technology

    2016-06-01

    ventilator, while the other two devices are stand-alone products. The fourth group of ETTs had the cuff pressure measured by the respiratory ...Maquet, Rastatt, Germany). To simulate a clinical environment, each model was ventilated using ventilator settings of respiratory rate of 12...rapidly changes with descent to below 10 cmH2O, allowing fluid above the cuff to readily move into the lower respiratory tract. As with ascent

  20. Automated cuff pressure modulation: a novel device to reduce endotracheal tube injury.

    PubMed

    Chadha, Neil K; Gordin, Arie; Luginbuehl, Igor; Patterson, Greg; Campisi, Paolo; Taylor, Glenn; Forte, Vito

    2011-01-01

    To assess whether dynamically modulating endotracheal tube (ETT) cuff pressure, by decreasing it during each ventilatory cycle instead of maintaining a constant level, would reduce the extent of intubation-related laryngotracheal injury. Single-blind, randomized controlled animal study using a previously validated live porcine model of accelerated intubation-related tracheal injury. Animal research facility. Ten piglets (weight, 16-20 kg each) were anesthetized and underwent intubation using a cuffed ETT. The animals were randomized into the following 2 groups: 5 pigs had a novel device to modulate their cuff pressure from 25 cm H₂O during inspiration to 7 cm H₂O during expiration, and 5 pigs had a constant cuff pressure of 25 cm H₂O. Both groups underwent ventilation under hypoxic conditions for 4 hours. Laryngotracheal mucosal injury after blinded histopathological assessment. The modulated-pressure group showed significantly less overall laryngotracheal damage than the constant-pressure group (mean grades, 1.2 vs 2.1; P < .001). Subglottic damage and tracheal damage were significantly less severe in the modulated-pressure group (mean grades, 1.0 vs 2.2; P < .001, and 1.9 vs 3.2; P < .001, respectively). There was no significant difference in glottic or supraglottic damage between the groups (P = .06 and .27, respectively). This novel device reduces the risk of subglottic and tracheal injury by modulating ETT cuff pressure in synchronization with the ventilatory cycle. This finding could have far-reaching implications for reducing the risk of airway injury in patients undergoing long-term intubation. Further clinical study of this device is warranted.

  1. [Microcuff pediatric tracheal tube. A new tracheal tube with a high volume-low pressure cuff for children].

    PubMed

    Weiss, M; Dullenkopf, A; Gerber, A C

    2004-01-01

    Principles and characteristics of the recently introduced Microcuff paediatric tracheal tube (Microcuff, GmbH, Weinheim, Germany) with anatomically based depth markings, cuff-free subglottic tube shaft and short high volume-low pressure cuff with ultrathin cuff membrane are presented. First available tubes (ID 4.0 mm) were evaluated regarding cuff pressures required to seal the trachea and regarding the distance from the tube tip to the carina. After obtaining approval of the local ethical committee, 20 children aged 2-4 years, receiving tracheal intubation under general anaesthesia with muscle paralysis, were included. The tubes were placed during direct laryngoscopy and the glottic depth marking placed between the vocal cords. Cuff pressure to prevent audible air leakage at standardised ventilator settings (PIP 20 cm H(2)O/PEEP 5 cm H(2)O/RR20 x min(-1)) was assessed by means of a cuff pressure manometer within 5 min after intubation. Subsequently, the distance from the tube tip to the tracheal carina was measured by means of fibre bronchoscopy. Data are presented as the median (range). Patient age was 3.0 years (2.0-3.9 years), weight 13.5 kg (9.1-19.2 kg) and body length 95 cm (79-105 cm). The lowest cuff pressure required to seal the trachea ranged from 4-14 cmH(2)O (median 10 cm H(2)O), the distance from tube tip to tracheal carina was to 2.9 cm (2.0-4.5 cm). The new Microcuff paediatric tracheal tube with ultrathin high volume-low pressure cuff required tracheal sealing pressures below tracheal wall pressures usually required with uncuffed tracheal tubes for efficient sealing and ventilation at 20 cm H(2)O peak inspiratory pressure. The distance from the tube tip to carina was in the safe range in all patients.

  2. Development of a cuffless blood pressure measurement system.

    PubMed

    Shyu, Liang-Yu; Kao, Yao-Lin; Tsai, Wen-Ya; Hu, Weichih

    2012-01-01

    This study constructs a novel blood pressure measurement device without the air cuff to overcome the problem of discomfort and portability. The proposed device measures the blood pressure through a mechanism that is made of silicon rubber and pressure transducer. The system uses a microcontroller to control the measurement procedure and to perform the necessary computation. To verify the feasibility of the constructed device, ten young volunteers were recruited. Ten blood pressure readings were obtained using the new system and were compared with ten blood pressure readings from bedside monitor (Spacelabs Medical, model 90367). The results indicated that, when all the readings were included, the mean pressure, systolic pressure and diastolic pressure from the new system were all higher than those from bedside monitor. The correlation coefficients between these two were 0.15, 0.18 and 0.29, for mean, systolic and diastolic pressures, respectively. After excluding irregular apparatus utilization, the correlation coefficient increased to 0.71, 0.60 and 0.41 for diastolic pressure, mean pressure and systolic pressure, respectively. We can conclude from these results that the accuracy can be improved effectively by defining the user regulation more precisely. The above mentioned irregular apparatus utilization factors can be identified and eliminated by the microprocessor to provide a reliable blood pressure measurement in practical applications in the future.

  3. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    PubMed

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P < .001 for both). Mean systolic pressures, but not mean diastolic pressures, in the upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  4. The origin of mean arterial and jugular venous blood pressures in giraffes.

    PubMed

    Mitchell, Graham; Maloney, Shane K; Mitchell, Duncan; Keegan, D James

    2006-07-01

    Using a mechanical model of the giraffe neck and head circulation consisting of a rigid, ascending, 'carotid' limb, a 'cranial' circulation that could be rigid or collapsible, and a descending, 'jugular' limb that also could be rigid or collapsible, we have analyzed the origin of the high arterial and venous pressures in giraffe, and whether blood flow is assisted by a siphon. When the tubes were rigid and the 'jugular' limb exit was lower than the 'carotid' limb entrance a siphon operated, 'carotid' hydrostatic pressures became more negative, and flow was 3.3 l min(-1) but ceased when the 'cranial' and 'jugular' limbs were collapsible or when the 'jugular' limb was opened to the atmosphere. Pumping water through the model produced positive pressures in the 'carotid' limb similar to those found in giraffe. Applying an external 'tissue' pressure to the 'jugular' tube during pump flow produced the typical pressures found in the jugular vein in giraffe. Constriction of the lowest, 'jugular cuff', portion of the 'jugular' limb showed that the cuff may augment the orthostatic reflex during head raising. Except when all tubes were rigid, pressures were unaffected by a siphon. We conclude that mean arterial blood pressure in giraffes is a consequence of the hydrostatic pressure generated by the column of blood in the neck, that tissue pressure around the collapsible jugular vein produces the known jugular pressures, and that a siphon does not assist flow through the cranial circulation.

  5. Method and Simple Apparatus for Teaching the Auscultatory Method for Measuring Human Blood Pressure to Large Classes.

    ERIC Educational Resources Information Center

    Geddes, L. A.

    1980-01-01

    Presents audiovisual methods to aid instruction in measuring blood pressure by indirect methods, so that a large screen display for cuff pressure is produced and high intensity Korotkoff sounds are amplified. (CS)

  6. Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring

    NASA Astrophysics Data System (ADS)

    Woo, Sung Hun; Choi, Yun Young; Kim, Dae Jung; Bien, Franklin; Kim, Jae Joon

    2014-10-01

    Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, they mostly involve physical inconveniences such as pressure or stress on the human body. Here, we introduce a new non-invasive mechanism of tissue-informative measurement, where an experimental phenomenon called subcutaneous tissue pressure equilibrium is revealed and related for application in detection of absolute blood pressure. A prototype was experimentally verified to provide an absolute blood pressure measurement by wearing a watch-type measurement module that does not cause any discomfort. This work is supposed to contribute remarkably to the advancement of continuous non-invasive mobile devices for 24-7 daily-life ambulatory blood-pressure monitoring.

  7. Obesity, hypertension and home sphygmomanometer cuffs.

    PubMed

    Akpolat, Tekin

    2010-08-01

    Since the increasing prevalence of obesity leads to a larger mean arm circumferences in the hypertensive population and appropriate cuff size is essential for accurate measurement of blood pressure, overweight and obese patients often require automated home sphygmomanometers with large- or extra large-sized cuffs. The aims of this study were to evaluate the information about cuff size on automated upper arm home sphygmomanometer packing boxes and compare the findings with wrist device boxes. One hundred twelve different device boxes (49 automated upper arm, 5 semi-automatic, and 58 wrist) produced by 40 manufacturers were investigated. Three different types of information were observed (written, graphical, or a combination of both). There was not any information about cuff size on 49 (44%) device boxes. Most of the information expressed on the boxes was not attractive or informative for the patients. This study showed that the information regarding cuff size on most of the device boxes was obtuse and the patients are not warned sufficiently about appropriate cuff size. Physicians and health care providers should inform and train their patients about appropriate cuff size.

  8. Pediatric Endotracheal Tube Cuff Pressures During Aeromedical Transport.

    PubMed

    Orsborn, Jonathan; Graham, James; Moss, Michele; Melguizo, Maria; Nick, Todd; Stroud, Michael

    2016-01-01

    Cuffed endotracheal tubes (ETTs) are frequently used in children, allowing fewer air leaks and helping prevent ventilator-associated pneumonia. Tracheal mucosal perfusion is compromised at an ETT cuff pressure (ETTCP) of 30 cm H2O with blood flow completely absent above 50 cm H2O. Our objective was to compare multiple pediatric-sized ETTCPs at ground level and various altitudes during aeromedical transport. Simulating the transport environment, 4 pediatric-sized mannequin heads were intubated with appropriately sized cuffed ETTs (3.0, 4.0, 5.0, 6.0) and transported by helicopter or nonpressurized fixed-wing aircraft 20 times each. The ETTCP was set to 10 cm H2O before transport, and the pressure was measured with a standard manometer at 1000-ft intervals until reaching peak altitude or CP greater than 60 cm H2O. Ground elevation ranged from 400-650 ft mean sea level (MSL) and peak altitude from 3500 to 5000 ft MSL. Increased altitude caused a significant increase in ETTCP of all ETT sizes (P < 0.001). However, there is no statistical difference in pressures between ETT sizes (P = 0.28). On average, ETTCP in 3.0, 4.0, and 6.0 ETTs surpassed 30 cm H2O at approximately 1500 ft MSL and 50 cm H2O at approximately 2800 ft MSL. In the 5.0 ETT, the CP reached 30 cm H2O at 2000 ft MSL and 50 cm H2O at 3700 ft MSL. The ETTCP in pediatric-sized ETTs regularly exceed recommended pressure limits at relatively low altitudes. There is no additional pressure increase related to ETT size. This has the potential to decrease mucosal blood flow, possibly increasing risk of subsequent tracheal stenosis, rupture, and other complications.

  9. Automatic Blood Pressure Measurements During Exercise

    NASA Technical Reports Server (NTRS)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  10. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.

    PubMed

    Irving, Greg; Holden, John; Stevens, Richard; McManus, Richard J

    2016-11-03

    To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. BP measurement

  11. Non-invasive determination of instantaneous brachial blood flow using the oscillometric method.

    PubMed

    Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan

    2009-08-01

    The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r = 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.

  12. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  13. Arterial blood pressure estimation using ultrasound: Clinical results on healthy volunteers and a medicated hypertensive volunteer.

    PubMed

    Zakrzewski, Aaron M; Anthony, Brian W

    2017-07-01

    This study presents a non-occlusive and non-invasive ultrasound-based technique to measure blood pressure. Most popular clinically-used arterial blood pressure measurement techniques suffer from important weaknesses including being inaccurate, invasive, or occlusive. In the proposed technique, an ultrasound probe is placed on the patient's carotid artery and the contact force between the probe and the tissue is slowly increased while ultrasound images and contact force data are recorded. From this data, the artery is segmented and the segmentation data is sent into an optimization procedure; after post-processing, blood pressure is displayed to the user. This technique was applied to 24 healthy single-visit volunteers, one multi-visit healthy volunteer, and one multi-visit medicated hypertensive volunteer. Compared to the oscillometric cuff, the accuracy and precision of the algorithm-reported systolic pressure is -2.4 ± 10.2 mmHg, and for diastolic pressure is -0.3 ± 8.2 mmHg. This method has the potential to occupy a clinical middle-ground between the arterial catheter and the oscillometric cuff.

  14. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

    PubMed

    Pickering, Thomas G; Hall, John E; Appel, Lawrence J; Falkner, Bonita E; Graves, John; Hill, Martha N; Jones, Daniel W; Kurtz, Theodore; Sheps, Sheldon G; Roccella, Edward J

    2005-01-01

    Accurate measurement of blood pressure is essential to classify individuals, to ascertain blood pressure-related risk, and to guide management. The auscultatory technique with a trained observer and mercury sphygmomanometer continues to be the method of choice for measurement in the office, using the first and fifth phases of the Korotkoff sounds, including in pregnant women. The use of mercury is declining, and alternatives are needed. Aneroid devices are suitable, but they require frequent calibration. Hybrid devices that use electronic transducers instead of mercury have promise. The oscillometric method can be used for office measurement, but only devices independently validated according to standard protocols should be used, and individual calibration is recommended. They have the advantage of being able to take multiple measurements. Proper training of observers, positioning of the patient, and selection of cuff size are all essential. It is increasingly recognized that office measurements correlate poorly with blood pressure measured in other settings, and that they can be supplemented by self-measured readings taken with validated devices at home. There is increasing evidence that home readings predict cardiovascular events and are particularly useful for monitoring the effects of treatment. Twenty-four-hour ambulatory monitoring gives a better prediction of risk than office measurements and is useful for diagnosing white-coat hypertension. There is increasing evidence that a failure of blood pressure to fall during the night may be associated with increased risk. In obese patients and children, the use of an appropriate cuff size is of paramount importance.

  15. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

    PubMed

    Pickering, Thomas G; Hall, John E; Appel, Lawrence J; Falkner, Bonita E; Graves, John; Hill, Martha N; Jones, Daniel W; Kurtz, Theodore; Sheps, Sheldon G; Roccella, Edward J

    2005-02-08

    Accurate measurement of blood pressure is essential to classify individuals, to ascertain blood pressure-related risk, and to guide management. The auscultatory technique with a trained observer and mercury sphygmomanometer continues to be the method of choice for measurement in the office, using the first and fifth phases of the Korotkoff sounds, including in pregnant women. The use of mercury is declining, and alternatives are needed. Aneroid devices are suitable, but they require frequent calibration. Hybrid devices that use electronic transducers instead of mercury have promise. The oscillometric method can be used for office measurement, but only devices independently validated according to standard protocols should be used, and individual calibration is recommended. They have the advantage of being able to take multiple measurements. Proper training of observers, positioning of the patient, and selection of cuff size are all essential. It is increasingly recognized that office measurements correlate poorly with blood pressure measured in other settings, and that they can be supplemented by self-measured readings taken with validated devices at home. There is increasing evidence that home readings predict cardiovascular events and are particularly useful for monitoring the effects of treatment. Twenty-four-hour ambulatory monitoring gives a better prediction of risk than office measurements and is useful for diagnosing white-coat hypertension. There is increasing evidence that a failure of blood pressure to fall during the night may be associated with increased risk. In obese patients and children, the use of an appropriate cuff size is of paramount importance.

  16. Effects of nandrolone and resistance training on the blood pressure, cardiac electrophysiology, and expression of atrial β-adrenergic receptors.

    PubMed

    das Neves, Vander José; Tanno, Ana Paula; Cunha, Tatiana Sousa; Fernandes, Tiago; Guzzoni, Vinicius; da Silva, Carlos Alberto; de Oliveira, Edilamar Menezes; Moura, Maria José Costa Sampaio; Marcondes, Fernanda Klein

    2013-05-30

    This study was performed to assess isolated and combined effects of nandrolone and resistance training on the blood pressure, cardiac electrophysiology, and expression of the β1- and β2-adrenergic receptors in the heart of rats. Wistar rats were randomly divided into four groups and submitted to a 6-week treatment with nandrolone and/or resistance training. Cardiac hypertrophy was accessed by the ratio of heart weight to the final body weight. Blood pressure was determined by a computerized tail-cuff system. Electrocardiography analyses were performed. Western blotting was used to access the protein levels of the β1- and β2-adrenergic receptors in the right atrium and left ventricle. Both resistance training and nandrolone induced cardiac hypertrophy. Nandrolone increased systolic blood pressure depending on the treatment time. Resistance training decreased systolic, diastolic and mean arterial blood pressure, as well as induced resting bradycardia. Nandrolone prolonged the QTc interval for both trained and non-trained groups when they were compared to their respective vehicle-treated one. Nandrolone increased the expression of β1- and β2-adrenergic receptors in the right atrium for both trained and non-trained groups when they were compared to their respective vehicle-treated one. This study indicated that nandrolone, associated or not with resistance training increases blood pressure depending on the treatment time, induces prolongation of the QTc interval, and increases the expression of β1- and β2-adrenergic receptors in the cardiac right atrium, but not in the left ventricle. Copyright © 2013. Published by Elsevier Inc.

  17. [Analysis of compliance of 2 prevention measures for ventilator-associated pneumonia (raised head of bed and cuff pressure control)].

    PubMed

    del Cotillo Fuente, M; Valls Matarín, J

    2014-01-01

    To quantify the hours of mechanical ventilation in patients with head of bed elevation≥30°. Determining compliance of cuff measurement every 6h. Descriptive longitudinal study. Measured: time head of bed elevation≥30°, <30° and reasons for non compliance, as well as cuff control every 6h. One hundred and seventy-two records of head of bed elevation and 584 of cuff pressure. Daily average head<30° for care or procedures: 2h (1h19'). The theoretical average number of hours that patients should remain at≥30° was 21h15' (3h) and actual 14h (5h) (P<.001). Registration of cuff was 76,7%. Cuffs between 20-30cmH2O were 75.9%. The 20% of cuff pressure were measured every 6h<20cmH2O and 33.7% when the interval was higher (P=.04). A third of the day patients are<30° without justification. Cuff pressure registration and percentage of therapeutic range are high. Control every 6h decreases the cuff with pressure<20cmH2O. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  18. Blood pressure monitoring: theory and practice. European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability Teaching Course Proceedings.

    PubMed

    Stergiou, George S; Palatini, Paolo; Asmar, Roland; Bilo, Grzegorz; de la Sierra, Alejandro; Head, Geoff; Kario, Kazuomi; Mihailidou, Anastasia; Wang, Jiguang; Mancia, Giuseppe; O'Brien, Eoin; Parati, Gianfranco

    2018-02-01

    The European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and Cardiovascular Variability organized a Teaching Course on 'Blood Pressure Monitoring: Theory and Practice' during the 2017 ESH Meeting in Milan, Italy. This course performed by 11 international BP monitoring experts covered key topics of BP monitoring, including office BP measurement, ambulatory BP monitoring, home BP monitoring, ambulatory versus home BP, white-coat and masked hypertension, cuff use, and BP variability. This article presents a summary of the proceedings of the ESH BP Monitoring Teaching Course, including essential information, practical issues, and recommendations on the clinical application of BP monitoring methods, aiming to the optimal management of patients with suspected or diagnosed hypertension.

  19. Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.

    PubMed

    Borhazowal, Rishiraj; Harde, Minal; Bhadade, Rakesh; Dave, Sona; Aswar, Swapnil Ganeshrao

    2017-06-01

    The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. We aimed to compare Just-Seal (JS) and Stethoscope-Guided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H 2 O in the JS and 29.64 cm H 2 O in SG with p=2.29E-14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.

  20. Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: a randomized trial.

    PubMed

    Valencia, Mauricio; Ferrer, Miquel; Farre, Ramon; Navajas, Daniel; Badia, Joan Ramon; Nicolas, Josep Maria; Torres, Antoni

    2007-06-01

    The aspiration of subglottic secretions colonized by bacteria pooled around the tracheal tube cuff due to inadvertent deflation (<20 cm H2O) of the cuff plays a relevant role in the pathogenesis of ventilator-associated pneumonia. We assessed the efficacy of an automatic, validated device for the continuous regulation of tracheal tube cuff pressure in preventing ventilator-associated pneumonia. Prospective randomized controlled trial. Respiratory intensive care unit and general medical intensive care unit. One hundred and forty-two mechanically ventilated patients (age, 64 +/- 17 yrs; Acute Physiology and Chronic Health Evaluation II score, 18 +/- 6) without pneumonia or aspiration at admission. Within 24 hrs of intubation, patients were randomly allocated to undergo continuous regulation of the cuff pressure with the automatic device (n = 73) or routine care of the cuff pressure (control group, n = 69). Patients remained in a semirecumbent position in bed. The primary end point variable was the incidence of ventilator-associated pneumonia. Main causes for intubation were decreased consciousness (43, 30%) and exacerbation of chronic respiratory diseases (38, 27%). Cuff pressure <20 cm H2O was more frequently observed in the control than the automatic group (45.3 vs. 0.7% determinations, p < .001). However, the rate of ventilator-associated pneumonia with clinical criteria (16, 22% vs. 20, 29%) and microbiological confirmation (11, 15% vs. 10, 15%), the distribution of early and late onset, the causative microorganisms, and intensive care unit (20, 27% vs. 16, 23%) and hospital mortality (30, 41% vs. 23, 33%) were similar for the automatic and control groups, respectively. Cuff pressure is better controlled with the automatic device. However, it did not result in additional benefits to the semirecumbent position in preventing ventilator-associated pneumonia.

  1. Combined electric and pressure cuff pain stimuli for assessing conditioning pain modulation (CPM).

    PubMed

    Tsukamoto, M; Petersen, K K; Mørch, C D; Arendt-Nielsen, L

    2017-12-29

    Aims Traditionally, conditioning pain modulation (CPM) can be assessed by applying a test stimulus (TS) before and after application of a conditioning stimulus (CS), which is normally applied extra-segmental. Currently, no studies have attempted to apply the TS and CS to the same site using different stimuli modalities. The aim of this study was to evaluate electrical TS and cuff pressure CS applied to the same experimental site for studying CPM. Methods 20 male volunteers participated in this study, which consisted of stimulations applied by a cuff-algometer (NociTech and Aalborg University, Denmark) and current stimulator (Digitimer DS5, UK), through two Ag/AgCl electrodes (Ambu® Neuroline 700, Denmark). The cuff was wrapped around the lower leg and stimulation electrodes were placed under the cuff and to the same location on the contralateral leg. Electrical TS were applied to the non-dominant leg with or without cuff pressure CS on the dominant (CS1) or the same (non-dominant) leg (CS2, electrode under cuff). The subjects were instructed to rate the electrical evoked pain intensity on a 10-cm continuous visual analog scale (VAS, "0" represented "no pain", and "10" represented "maximal pain"). The pain detection threshold (PDT) was defined as "1" on the VAS scale. Results There was no significant deference in PDT for neither CS1 nor CS2. A median split subanalysis on CPM-responders versus CPM-nonresponders to the TS + CS1 combination. Using this grouping, there was significant increase in PDT when comparing TS to TS + CS1 or TS + CS2 (4.0 mA vs 5.6 mA; P < 0.05, 4.0 mA vs 5.1 mA; P < 0.05). Conclusions The study indicates that CPM can be evoked in a subgroup of subjects by applying the electrical test stimulus and cuff pressure conditioning stimuli to the same experimental site.

  2. [Nitrous Oxide Exposure-mediated Increases in Cuff Pressure: A Comparison of Disposable Type and Re-use Type air-Q Devices].

    PubMed

    Miyazaki, Yu; Komasawa, Nobuyasu; Fujiawara, Shunsuke; Majima, Nozomi; Tatsumi, Shinichi; Minami, Toshiaki

    2015-02-01

    BaCKGROUND: The present study aimed to compare nitrous oxide-mediated increases in cuff pressure between the disposable type air-Q (air-Q-DT) and re-use type air-Q (air-Q-RU) in a simulated adult airway model. Automated cuff pressure was adjusted to 10, 20, and 30 cmH2O. The air-Q-DT and air-Q-RU were exposed to 80% nitrous oxide and cuff pressure was measured 15 and 30 minutes later. Cuff pressure of the air-Q-DT was significantly lower than that of the air-Q-RU after 15 and 30 minutes, regardless of the initial pressure. The polyvinyl chloride-based air-Q-DT may be more effective than the silicon-based air-Q-RU in preventing hyperinflation of the tracheal tube cuff in response to nitrous oxide exposure.

  3. Changes in extracellular muscle volume affect heart rate and blood pressure responses to static exercise

    NASA Astrophysics Data System (ADS)

    Baum, K.; Essfeld, D.; Stegemann, J.

    To investigate the effect of μg-induced peripheral extracellular fluid reductions on heart rate and blood pressure during isometric exercise, six healthy male subjects performed three calf ergometer test with different extracellular volumes of working muscles. In all tests, body positions during exercise were identical (supine with the knee joint flexed to 900). After a pre-exercise period of 25 min, during which calf volumes were manipulated, subjects had to counteract an external force of 180 N for 5 min. During the pre-exercise period three different protocols were applied. Test A: Subjects rested in the exercise position; test B: Body position was the same as in A but calf volume was increased by venous congestion (cuffs inflated to 80 mm Hg); test C: Calf volumes were decreased by a negative hydrostatic pressure (calves about 40 cm above heart level with the subjects supine). To clamp the changed calf volumes in tests B and C, cuffs were inflated to 300 mm Hg 5 min before the onset of exercise. This occlusion was maintained until termination of exercise. Compared to tests A and B, the reduced volume of test C led to significant increases in heart rate and blood pressure during exercise. Oxygen uptake did not exceed resting levels in B and C until cuffs were deflated, indicating that exclusively calf muscles contributed to the neurogenic peripheral drive. It is concluded that changes in extracellular muscle volume have to be taken into account when comparing heart rate and blood pressure during lg- and μg- exercise.

  4. [In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes].

    PubMed

    Coelho, Rafael de Macedo; Paiva, Thiago Trigueiro Morais de; Mathias, Ligia Andrade da Silva Telles

    2016-01-01

    Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30cm H2O. Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5 to 8.5), using three times inflation (10, 15 and 20seconds), totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30cm H2O or <20cm H2O were considered failures. There were eight failures (0.5%, 95% CI: 0.1-0.9%), with all by pressures <20cm H2O and after 10seconds inflation (1.6%, 95% CI: 0 5-2.7%). One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3-0.9%), six with 7.0 tubes (2%, 95% CI: 0.4 to 3.6%), and one with a 7.5 tube (0.3%, 95% CI: -0.3-0.9%). This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%). Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes.

    PubMed

    Coelho, Rafael de Macedo; de Paiva, Thiago Trigueiro Morais; da Silva Telles Mathias, Ligia Andrade

    2016-01-01

    Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30cm H2O. Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5-8.5), using three times inflation (10, 15 and 20s), totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30cm H2O or <20cm H2O were considered failures. There were eight failures (0.5%, 95% CI: 0.1-0.9%), with all by pressures <20cm H2O and after 10s inflation (1.6%, 95% CI: 0 5-2.7%). One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3 to 0.9%), six with 7.0 tubes (2%, 95% CI: 0.4-3.6%), and one with a 7.5 tube (0.3%, 95% CI: -0.3 to 0.9%). This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%). Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  6. Validity and Usefulness of `Wearable Blood Pressure Sensing' for Detection of Inappropriate Short-Term Blood Pressure Variability in the Elderly

    NASA Astrophysics Data System (ADS)

    Iijima, Katsuya; Kameyama, Yumi; Akishita, Masahiro; Ouchi, Yasuyoshi; Yanagimoto, Shintaro; Imai, Yasushi; Yahagi, Naoki; Lopez, Guillaume; Shuzo, Masaki; Yamada, Ichiro

    An increase in short-term blood pressure (BP) variability is a characteristic feature in the elderly. It makes the management of hemodynamics more difficult, because it is frequently seen disturbed baro-reflex function and increased arterial stiffness, leading to isolated systolic hypertension. Large BP variability aggravates hypertensive target organ damage and is an independent risk factor for the cardiovascular (CV) events in elderly hypertensive patients. Therefore, appropriate control in BP is indispensable to manage lifestyle-related diseases and to prevent subsequent CV events. In addition, accumulating recent reports show that excessive BP variability is also associated with a decline in cognitive function and fall in the elderly. In the clinical settings, we usually evaluate their health condition, mainly with single point BP measurement using cuff inflation. However, unfortunately we are not able to find the close changes in BP by the traditional way. Here, we can show our advantageous approach of continuous BP monitoring using newly developing device `wearable BP sensing' without a cuff stress in the elderly. The new device could reflect systolic BP and its detailed changes, in consistent with cuff-based BP measurement. Our new challenge suggests new possibility of its clinical application with high accuracy.

  7. Development of a wireless blood pressure measuring device with smart mobile device.

    PubMed

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.

    PubMed

    Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny

    2014-03-01

    Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30  cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72  h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25  cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49  ml  min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63  ml  min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17  ml  min⁻¹ with continuous cuff pressure monitoring (P <0.001). Using a SACETT tracheal tube with a subglottic aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48  ml  min⁻¹ (P <0.001). Subglottic secretions leaked past the tracheal tube cuff with all tube types and cuff pressure monitoring strategies in this model. Significantly higher rates were observed with continuous cuff pressure monitoring and significantly lower rates were observed when using a tracheal tube with a subglottic aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.

  9. Evaluation of a teaching tool to increase the accuracy of pilot balloon palpation for measuring tracheostomy tube cuff pressure.

    PubMed

    Jiang, Nancy; Del Signore, Anthony G; Iloreta, Alfred M; Malkin, Benjamin D

    2013-08-01

    The purpose of this study was to evaluate the efficacy of a novel teaching tool to improve health care providers' ability to inflate tracheostomy tube cuffs to the appropriate pressure. Single-blinded, randomized, controlled trial. Subjects were randomized to a control and study group. The control group viewed a video about inflating tracheostomy tube cuffs to safe pressure levels. The study group viewed the same video and also got to palpate the pilot balloons of tracheostomy tube cuffs inflated to three different pressures. All subjects inflated tracheostomy tube cuffs to pressures they believed to be appropriate based on palpation of the pilot balloon preintervention, and immediately, 2 weeks, and 3 months postintervention. Forty-nine health care providers participated in the study. There was no significant difference in the mean preintervention cuff inflation pressures between the two groups (36 cm H2 O vs. 38 cm H2 O, P = 0.4888), with both initially overinflating. Postintervention, the study group inflated the cuffs to significantly lower pressures than the control group, closer to the ideal of 25 cm H2 O (26 cm H2 O vs. 35 cm H2 O, P = 0.0001). This difference was also observed 2 weeks (28 cm H2 O vs. 37 cm H2 O P <0.0001) and 3 months (28 cm H2 O vs. 36 cm H2 O, P = 0.0002) postintervention. The novel teaching tool evaluated in this study is simple, easily reproducible, and low-cost. Its use leads to long-lasting improvement in health care providers' ability to more accurately inflate tracheostomy tube cuffs to safe pressures. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Ablation of the GNB3 gene in mice does not affect body weight, metabolism or blood pressure, but causes bradycardia

    PubMed Central

    Ye, Yuanchao; Sun, Zhizeng; Guo, Ang; Song, Long-sheng; Grobe, Justin L.; Chen, Songhai

    2014-01-01

    G protein β3 (Gβ3) is an isoform of heterotrimeric G protein β subunits involved in transducing G protein coupled receptor (GPCR) signaling. Polymorphisms in Gβ3 (GNB3) are associated with many human disorders (e.g. hypertension, diabetes and obesity) but the role of GNB3 in these pathogeneses remains unclear. Here, Gβ3-null mice (GNB3−/−) were characterized to determine how Gβ3 functions to regulate blood pressure, body weight and metabolism. We found Gβ3 expression restricted to limited types of tissues, including the retina, several regions of brain and heart ventricles. Gβ3-deficient mice were normal as judged by body weight gain by age or by feeding with high-fat diet (HFD); glucose tolerance and insulin sensitivity; baseline blood pressure and angiotensin II infusion-induced hypertension. During tail-cuff blood pressure measurements, however, Gβ3-null mice had slower heart rates (~450 vs ~500 beats/min). This bradycardia was not observed in isolated and perfused Gβ3-null mouse hearts. Moreover, mouse hearts isolated from GNB3−/− and controls responded equivalently to muscarinic receptor- and β-adrenergic receptor-stimulated bradycardia and tachycardia, respectively. Since no difference was seen in isolated hearts, Gβ3 is unlikely to be involved directly in the GPCR signaling activity that controls heart pacemaker activity. These results demonstrate that although Gβ3 appears dispensable in mice for regulation of blood pressure, body weight and metabolic features associated with obesity and diabetes, Gβ3 may regulate heart rate. PMID:25093805

  11. Increased blood flow in the anterior humeral circumflex artery correlates with night pain in patients with rotator cuff tear.

    PubMed

    Terabayashi, Nobuo; Watanabe, Tsuneo; Matsumoto, Kazu; Takigami, Iori; Ito, Yoshiki; Fukuta, Masashi; Akiyama, Haruhiko; Shimizu, Katsuji

    2014-09-01

    Night pain is a particularly vexing symptom in patients with rotator cuff tear. It disturbs sleep and decreases quality of life, and there is no consensus regarding its etiology. Based on arthroscopic surgical observations of synovitis around the rotator interval or capsule surface in rotator cuff tear, we hypothesized that blood flow from the artery feeding the capsule increases blood supply to the synovium. This study aimed to investigate the relationship between blood flow and night pain using pulse Doppler ultrasonography. A series of 47 consecutive patients with rotator cuff tear was evaluated. The peak systolic velocity and resistance index of blood flow in the ascending branch of the anterior humeral circumflex artery were evaluated using pulse Doppler ultrasonography. We also investigated 20 normal shoulders in healthy volunteers. The peak systolic velocity and resistance index were compared between affected and unaffected sides in patients and between dominant and nondominant sides in controls. Anterior humeral circumflex artery peak systolic velocity and resistance index did not differ between sides in control subjects or in patients with rotator cuff tear without night pain. However, anterior humeral circumflex artery peak systolic velocity and resistance index did differ significantly between sides in patients with rotator cuff tear with night pain. This study revealed anterior humeral circumflex artery hemodynamics in patients with rotator cuff tear and normal subjects using Doppler ultrasonography. Night pain, particularly involving aching, appears to be related to the hemodynamics. These findings suggest that investigating the hemodynamics of patients with rotator cuff tear with night pain may lead to greater understanding of the etiology of this symptom.

  12. Dose-Response Evaluation of Braslet-M Occlusion Cuffs

    NASA Technical Reports Server (NTRS)

    Ebert, Douglas; Garcia, Kathleen; Sargsyan, Ashot E.; Ham, David; Hamilton, Douglas; Dulchavsky, Scott A.

    2010-01-01

    Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current

  13. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the

  14. Telling tails: selective pressures acting on investment in lizard tails.

    PubMed

    Fleming, Patricia A; Valentine, Leonie E; Bateman, Philip W

    2013-01-01

    Caudal autotomy is a common defense mechanism in lizards, where the animal may lose part or all of its tail to escape entrapment. Lizards show an immense variety in the degree of investment in a tail (i.e., length) across species, with tails of some species up to three or four times body length (snout-vent length [SVL]). Additionally, body size and form also vary dramatically, including variation in leg development and robustness and length of the body and tail. Autotomy is therefore likely to have fundamentally different effects on the overall body form and function in different species, which may be reflected directly in the incidence of lost/regenerating tails within populations or, over a longer period, in terms of relative tail length for different species. We recorded data (literature, museum specimens, field data) for relative tail length (n=350 species) and the incidence of lost/regenerating tails (n=246 species). We compared these (taking phylogeny into account) with intrinsic factors that have been proposed to influence selective pressures acting on caudal autotomy, including body form (robustness, body length, leg development, and tail specialization) and ecology (foraging behavior, physical and temporal niches), in an attempt to identify patterns that might reflect adaptive responses to these different factors. More gracile species have relatively longer tails (all 350 spp., P < 0.001; also significant for five of the six families tested separately), as do longer (all species, P < 0.001; Iguanidae, P < 0.05; Lacertidae, P < 0.001; Scindidae, P < 0.001), climbing (all species, P < 0.05), and diurnal (all species, P < 0.01; Pygopodidae, P < 0.01) species; geckos without specialized tails (P < 0.05); or active-foraging skinks (P < 0.05). We also found some relationships with the data for caudal autotomy, with more lost/regenerating tails for nocturnal lizards (all 246 spp., P < 0.01; Scindidae, P < 0.05), larger skinks (P < 0.05), climbing geckos (P < 0

  15. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    PubMed

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  16. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    PubMed

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  17. Does cuff pressure monitoring reduce postoperative pharyngolaryngeal adverse events after LMA-ProSeal insertion? A parallel group randomised trial.

    PubMed

    Vasanth Karthik, R; Ranganathan, Priya; Kulkarni, Atul P; Sharma, Kailash S

    2014-10-01

    The incidence of postoperative pharyngolaryngeal complications after laryngeal mask airway (LMA) insertion can be as high as 50%. Over-inflation of the LMA cuff may be a causal factor. We conducted a single-centre parallel group randomised trial to determine whether maintaining LMA-ProSeal intra-cuff pressures below 60 cm H2O decreases postoperative pharyngolaryngeal complications. We recruited 120 adult patients who were scheduled to undergo elective surgery under general anaesthesia. Appropriate sized LMA-ProSeal was inserted and the cuff was inflated with air (to no more than the maximum recommended volume) until there was no audible leak. Patients were randomised to either the control group (n = 60), where the intra-cuff pressure was noted and no further action was taken, or to the pressure-monitored group (n = 60), where intra-cuff pressure was maintained below 60 cm H2O. Pharyngolaryngeal complications consisting of sore throat, dysphonia and dysphagia were assessed at 1, 2, and 24 h postoperatively. Patients, anaesthesiologists and assessors were blinded to group allocation. The primary outcome was a composite endpoint of any pharyngolaryngeal complication at any of the three time points. Secondary outcomes were the incidence of individual outcomes at each time point. The incidence of pharyngolaryngeal complications at any time point was 42% in the routine care group and 32% in the pressure-monitored group (95% CI for difference +28 to -7%, p = 0.26). There was no difference between groups for any of the secondary outcomes. Our study failed to demonstrate a statistically significant reduction in postoperative pharyngolaryngeal complications by limiting intra-cuff pressures in the LMA-Proseal.

  18. The minimal leak test technique for endotracheal cuff maintenance.

    PubMed

    Harvie, D A; Darvall, J N; Dodd, M; De La Cruz, A; Tacey, M; D'Costa, R L; Ward, D

    2016-09-01

    Endotracheal tube (ETT) cuff pressure management is an essential part of airway management in intubated and mechanically ventilated patients. Both under- and over-inflation of the ETT cuff can lead to patient complications, with an ideal pressure range of 20-30 cmH 2 O defined. A range of techniques are employed to ensure adequate ETT cuff inflation, with little comparative data. We performed an observational cross-sectional study in a tertiary metropolitan ICU, assessing the relationship between the minimal leak test and cuff manometry. Forty-five mechanically ventilated patients, over a three-month period, had ETT cuff manometry performed at the same time as their routine cuff maintenance (minimal leak test). Bedside nurse measurements were compared with investigator measurements. At the endpoint of cuff inflation, 20 of 45 patients (44%) had cuff pressures between 20 and 30 cmH 2 O; 11 of 45 patients (24%) had cuff pressures <20 cmH 2 O; 14 of 45 patients (31%) had cuff pressures ≥30 cmH 2 O. Univariate analysis demonstrated an association between both patient obesity and female gender requiring less ETT cuff volume ( P =0.008 and P <0.001 respectively), though this association was lost on multivariate analysis. No association was demonstrated between any measured variables and cuff pressures. Inter-operator reliability in performing the minimal leak test showed no evidence of bias between nurse and investigators (Pearson coefficient = 0.897). We conclude the minimal leak test for maintenance of ETT cuffs leads to both over- and under-inflation, and alternative techniques, such as cuff manometry, should be employed.

  19. Maternal exposure to di-(2-ethylhexyl) phthalate exposure deregulates blood pressure, adiposity, cholesterol metabolism and social interaction in mouse offspring.

    PubMed

    Lee, Kuan-I; Chiang, Chin-Wei; Lin, Hui-Ching; Zhao, Jin-Feng; Li, Cheng-Ta; Shyue, Song-Kun; Lee, Tzong-Shyuan

    2016-05-01

    Long-term exposure to di-(2-ethylhexyl) phthalate (DEHP) is highly associated with carcinogenicity, fetotoxicity, psychological disorders and metabolic diseases, but the detrimental effects and mechanisms are not fully understood. We investigated the effect of exposing mouse mothers to DEHP, and the underlying mechanism, on blood pressure, obesity and cholesterol metabolism as well as psychological and learning behaviors in offspring. Tail-cuff plethysmography was used for blood pressure measurement; Western blot used was for phosphorylation and expression of protein; hematoxylin and eosin staining, Nissl staining and Golgi staining were used for histological examination. The serum levels of cholesterol, triglycerides and glucose were measured by blood biochemical analysis. Hepatic cholesterol and triglyceride levels were assessed by colorimetric assay kits. Offspring behaviors were evaluated by open-field activity, elevated plus maze, social preference test and Morris water maze. Maternal DEHP exposure deregulated the phosphorylation of endothelial nitric oxide synthase and upregulated angiotensin type 1 receptor in offspring, which led to increased blood pressure. It led to obesity in offspring by increasing the size of adipocytes in white adipose tissue and number of adipocytes in brown adipose tissue. It increased the serum level of cholesterol in offspring by decreasing the hepatic capacity for cholesterol clearance. The impaired social interaction ability induced by maternal DEHP exposure might be due to abnormal neuronal development. Collectively, our findings provide new evidence that maternal exposure to DEHP has a lasting effect on the physiological functions of the vascular system, adipose tissue and nerve system in offspring.

  20. Optimization of Endotracheal Tube Cuff Pressure by Monitoring CO2 Levels in the Subglottic Space in Mechanically Ventilated Patients: A Randomized Controlled Trial.

    PubMed

    Efrati, Shai; Bolotin, Gil; Levi, Leon; Zaaroor, Menashe; Guralnik, Ludmila; Weksler, Natan; Levinger, Uriel; Soroksky, Arie; Denman, William T; Gurman, Gabriel M

    2017-10-01

    Many of the complications of mechanical ventilation are related to inappropriate endotracheal tube (ETT) cuff pressure. The aim of the current study was to evaluate the effectiveness of automatic cuff pressure closed-loop control in patients under prolonged intubation, where presence of carbon dioxide (CO2) in the subglottic space is used as an indicator for leaks. The primary outcome of the study is leakage around the cuff quantified using the area under the curve (AUC) of CO2 leakage over time. This was a multicenter, prospective, randomized controlled, noninferiority trial including intensive care unit patients. All patients were intubated with the AnapnoGuard ETT, which has an extra lumen used to monitor CO2 levels in the subglottic space.The study group was connected to the AnapnoGuard system operating with cuff control adjusted automatically based on subglottic CO2 (automatic group). The control group was connected to the AnapnoGuard system, while cuff pressure was managed manually using a manometer 3 times/d (manual group). The system recorded around cuff CO2 leakage in both groups. Seventy-two patients were recruited and 64 included in the final analysis. The mean hourly around cuff CO2 leak (mm Hg AUC/h) was 0.22 ± 0.32 in the manual group and 0.09 ± 0.04 in the automatic group (P = .01) where the lower bound of the 1-sided 95% confidence interval was 0.05, demonstrating noninferiority (>-0.033). Additionally, the 2-sided 95% confidence interval was 0.010 to 0.196, showing superiority (>0.0) as well. Significant CO2 leakage (CO2 >2 mm Hg) was 0.027 ± 0.057 (mm Hg AUC/h) in the automatic group versus 0.296 ± 0.784 (mm Hg AUC/h) in the manual group (P = .025). In addition, cuff pressures were in the predefined safety range 97.6% of the time in the automatic group compared to 48.2% in the automatic group (P < .001). This study shows that the automatic cuff pressure group is not only noninferior but also superior compared to the manual cuff pressure group

  1. Effect of γ-aminobutyric acid and nattokinase-enriched fermented beans on the blood pressure of spontaneously hypertensive and normotensive Wistar-Kyoto rats.

    PubMed

    Suwanmanon, Kanintra; Hsieh, Pao-Chuan

    2014-12-01

    In this study we have evaluated the changes in arterial blood pressure in spontaneously hypertensive rats (SHR) caused by the short-term intake of Bacillus subtilis B060-fermented beans with significant γ-aminobutyric acid (GABA) and nattokinase activity. After being weaned, 7-week-old male SHR and 7-week-old male Wistar-Kyoto (WKY) rats were randomized into seven groups. Until the 8 th week of life, the rats in each group were given one of the following: Group 1, high dose of GABA and nattokinase in the SHR (SHD); Group 2, medium dose of GABA and nattokinase in the SHR (SMD); Group 3, low dose of GABA and nattokinase in the SHR (SLD); Group 4, negative control in the SHR (SD); Group 5, positive control in the SHR (SM); Group 6, high dose of GABA and nattokinase in the WKY (WHD); and Group 7, negative control in the WKY (WD). Distilled water served as the negative control, and captopril (50 mg/kg), a known ACE inhibitor, served as the positive control. Systolic blood pressure and diastolic blood pressure values were measured weekly from the 8 th week to the 16 th week of life using the tail-cuff method. A definite decrease in systolic and diastolic blood pressure values could be observed in the rats treated with captopril and in the rats that received GABA and nattokinase. The greatest antihypertensive effect was observed when the pharmacological treatment was administered. The effect of the daily intake of fermented beans containing GABA and nattokinase may be helpful in controlling blood pressure levels in hypertensive model animals. The fermentation of beans with B. subtilis B060 may therefore constitute a successful strategy for producing a functional food with antihypertensive activity. Copyright © 2014. Published by Elsevier B.V.

  2. The effect of deep-tissue massage therapy on blood pressure and heart rate.

    PubMed

    Kaye, Alan David; Kaye, Aaron J; Swinford, Jan; Baluch, Amir; Bawcom, Brad A; Lambert, Thomas J; Hoover, Jason M

    2008-03-01

    In the present study, we describe the effects of deep tissue massage on systolic, diastolic, and mean arterial blood pressure. The study involved 263 volunteers (12% males and 88% females), with an average age of 48.5. Overall muscle spasm/muscle strain was described as either moderate or severe for each patient. Baseline blood pressure and heart rate were measured via an automatic blood pressure cuff. Twenty-one (21) different soothing CDs played in the background as the deep tissue massage was performed over the course of the study. The massages were between 45 and 60 minutes in duration. The data were analyzed using analysis of variance with post-hoc Scheffe's F-test. Results of the present study demonstrated an average systolic pressure reduction of 10.4 mm Hg (p<0.06), a diastolic pressure reduction of 5.3 mm Hg (p<0.04), a mean arterial pressure reduction of 7.0 mm Hg (p<0.47), and an average heart rate reduction of 10.8 beats per minute (p<0.0003), respectively. Additional scientific research in this area is warranted.

  3. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure: a pooled analysis of 1018 population-based measurement studies with 88.6 million participants.

    PubMed

    2018-03-19

    Change in the prevalence of raised blood pressure could be due to both shifts in the entire distribution of blood pressure (representing the combined effects of public health interventions and secular trends) and changes in its high-blood-pressure tail (representing successful clinical interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. We pooled 1018 population-based studies with blood pressure measurements on 88.6 million participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence-mean association, to the change in prevalence of raised blood pressure. In 2005-16, at the same level of population mean SBP and DBP, men and women in South Asia and in Central Asia, the Middle East and North Africa would have the highest prevalence of raised blood pressure, and men and women in the high-income Asia Pacific and high-income Western regions would have the lowest. In most region-sex-age groups where the prevalence of raised blood pressure declined, one half or more of the decline was due to the decline in mean blood pressure. Where prevalence of raised blood pressure has increased, the change was entirely driven by increasing mean blood pressure, offset partly by the change in the prevalence-mean association. Change in mean blood pressure is the main driver of the worldwide change in

  4. Accurate blood pressure recording: is it difficult?

    PubMed

    Bhalla, A; Singh, R; D'cruz, S; Lehl, S S; Sachdev, A

    2005-11-01

    Blood pressure (BP) measurement is a routine procedure but errors are frequently committed during BP recording. AIMS AND SETTINGS: The aim of the study was to look at the prevalent practices in the institute regarding BP recording. The study was conducted in the Medicine Department at Government Medical College, Chandigarh, a teaching institute for MBBS students. A prospective, observational study was performed amongst the 80 doctors in a tertiary care hospital. All of them were observed by a single observer during the act of BP recording. The observer was well versed with the guidelines issued by British Hypertension Society (BHS) and the deviations from the standard set of guidelines issued by BHS were noted. The errors were defined as deviations from these guidelines. The results were recorded as percentage of doctors committing these errors. In our study, 90% used mercury type sphygmomanometer. Zero error of the apparatus, hand dominance was not noted by any one. Every one used the standard BP cuff for recording BP. 70% of them did not let the patient rest before recording BP. 80% did not remove the clothing from the arm. None of them recorded BP in both arms. In out patient setting, 80% recorded blood pressure in sitting position and 14% in supine position. In all the patients where BP was recorded in sitting position BP apparatus was below the level of heart and 20% did not have their arm supported. 60% did not use palpatory method for noticing systolic BP and 70% did not raise pressure 30-40 mm Hg above the systolic level before checking the BP by auscultation. 80% lowered the BP at a rate of more than 2 mm/s and 60% rounded off the BP to nearest 5-10 mm Hg. 70% recorded BP only once and 90% of the rest re inflated the cuff without completely deflating and allowing rest before a second reading was obtained. The practice of recording BP in our hospital varies from the standard guidelines issued by the BHS.

  5. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring.

    PubMed

    Stergiou, G S; Tzamouranis, D; Nasothimiou, E G; Protogerou, A D

    2008-11-01

    An appropriate cuff according to the individual's arm circumference is recommended with all blood pressure (BP) monitors. An electronic device for home monitoring has been developed (Visomat Comfort 20/40) that estimates the individual's arm circumference by measuring the cuff filing volume and makes an adjustment of measured BP taking into account the estimated arm circumference. Thus the manufacturer recommends the use of a single cuff for arm circumference 23-43 cm. The device accuracy was assessed using the European Society of Hypertension International Protocol. Simultaneous BP measurements were obtained in 33 adults by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute device-observer BP differences were classified into < or =5, < or =10 and < or =15 mm Hg zones. For each participant the number of measurements with a difference < or =5 mm Hg was calculated. The device produced 60/89/97 measurements within 5/10/15 mm Hg respectively for systolic BP, and 72/97/98 for diastolic. Twenty-three subjects had at least two of their systolic BP differences < or =5 mm Hg and three had no differences < or =5 mm Hg (for diastolic 27 and 1, respectively). Mean device-observer BP difference (systolic/diastolic) was 3.7 +/- 5.6/-1.5 +/- 4.7 mm Hg (4.7 +/- 4.9/ - 1.7 +/- 4.3 in arm circumference 23-29 cm [39 readings] and 3.1 +/- 5.9/-1.4 +/- 5.0 in arm 30-34 cm [60 readings], P=NS). In conclusion, the device fulfils the International Protocol requirements and can be recommended for clinical use. Interestingly, the device was accurate using a single cuff in a wide range of arm circumference (23-34 cm). This study provides no information about the device accuracy in larger arms.

  6. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    PubMed

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Cuff Pressure Pain Detection Is Associated with Both Sex and Physical Activity Level in Nonathletic Healthy Subjects.

    PubMed

    Lemming, Dag; Börsbo, Björn; Sjörs, Anna; Lind, Eva-Britt; Arendt-Nielsen, Lars; Graven-Nielsen, Thomas; Gerdle, Björn

    2017-08-01

    The aim of this study was to evaluate pressure pain sensitivity on leg and arm in 98 healthy persons (50 women) using cuff algometry. Furthermore, associations with sex and physical activity level were investigated. Normal physical activity level was defined as Godin Leisure-Time Exercise Questionnaire (GLTEQ) score ≤ 45 and high activity level as GLTEQ > 45. A pneumatic double-chamber cuff was placed around the arm or leg where a single chamber was inflated. The cuff inflation rate (1 kPa/s) was constant, and pain intensity was registered continuously on a 10 cm electronic visual analogue scale (VAS). The pain detection threshold (PDT) was defined as when the pressure was perceived as painful, and pain tolerance (PTT) was when the subject terminated the cuff inflation. For PTT, the corresponding VAS score was recorded (VAS-PTT). The protocol was repeated with two chambers inflated. Only single cuff results are given. For women compared with men, the PDT was lower when assessed in the arm ( P = 0.002), PTTs were lower in the arm and leg ( P < 0.001), and the VAS-PTT was higher in the arm and leg ( P < 0.033). Highly active participants compared with less active had higher PDT ( P = 0.027) in the leg. Women showed facilitated spatial summation ( P < 0.014) in the arm and leg and a steeper VAS slope (i.e., the slope of the VAS pressure curve between PDT and PPT) in the arm and leg ( P < 0.003). This study indicates that reduced pressure pain sensitivity is associated both with male sex and physical activity level. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    PubMed

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  9. Wearable and low-stress ambulatory blood pressure monitoring technology for hypertension diagnosis.

    PubMed

    Altintas, Ersin; Takoh, Kimiyasu; Ohno, Yuji; Abe, Katsumi; Akagawa, Takeshi; Ariyama, Tetsuri; Kubo, Masahiro; Tsuda, Kenichiro; Tochikubo, Osamu

    2015-01-01

    We propose a highly wearable, upper-arm type, oscillometric-based blood pressure monitoring technology with low-stress. The low-stress is realized by new developments in the hardware and software design. In the hardware design, conventional armband; cuff, is almost halved in volume thanks to a flexible plastic core and a liquid bag which enhances the fitness and pressure uniformity over the arm. Reduced air bag volume enables smaller motor pump size and battery leading to a thinner, more compact and more wearable unified device. In the software design, a new prediction algorithm enabled to apply less stress (and less pain) on arm of the patient. Proof-of-concept experiments on volunteers show a high accuracy on both technologies. This paper mainly introduces hardware developments. The system is promising for less-painful and less-stressful 24-hour blood pressure monitoring in hypertension managements and related healthcare solutions.

  10. Regulation of Blood Pressure by Targeting CaV1.2-Galectin-1 Protein Interaction.

    PubMed

    Hu, Zhenyu; Li, Guang; Wang, Jiong-Wei; Chong, Suet Yen; Yu, Dejie; Wang, Xiaoyuan; Soon, Jia Lin; Liang, Mui Cheng; Wong, Yuk Peng; Huang, Na; Colecraft, Henry M; Liao, Ping; Soong, Tuck Wah

    2018-04-12

    Background -L-type Ca V 1.2 channels play crucial roles in regulation of blood pressure. Galectin-1 (Gal-1), has been reported to bind to the I-II loop of Ca V 1.2 channels to reduce their current density. However, the mechanistic understanding for the down-regulation of Ca V 1.2 channels by Gal-1, and whether Gal-1 plays a direct role in blood pressure regulation remain unclear. Methods - In vitro experiments involving co-IP, western blot, patch-clamp recordings, immunohistochemistry and pressure myography were used to evaluate the molecular mechanisms by which Gal-1 down-regulates Ca V 1.2 channel in transfected HEK 293 cells, smooth muscle cells, arteries from Lgasl1 -/- mice, rat and human patients. In vivo experiments involving delivery of Tat-e9c peptide and AAV5-Gal-1 into rats were performed to investigate the effect of targeting Ca V 1.2-Gal-1 interaction on blood pressure monitored by tail cuff or telemetry methods. Results -Our study reveals that Gal-1 is a key regulator for proteasomal degradation of Ca V 1.2 channels. Gal-1 competed allosterically with Ca V β subunit for binding to the I-II loop of Ca V 1.2 channel. This competitive disruption of Ca V β binding led to Ca V 1.2 degradation by exposing the channels to poly-ubiquitination. Notably, we demonstrated that the inverse relationship of reduced Gal-1 and increased Ca V 1.2 protein levels in arteries was associated with hypertension in hypertensive rats and patients, and Gal-1 deficiency induces higher blood pressure in mice due to up-regulated Ca V 1.2 protein level in arteries. To directly regulate blood pressure by targeting the Ca V 1.2-Gal-1 interaction, we administered Tat-e9c, a peptide that competed for binding of Gal-1, by a mini-osmotic pump and this specific disruption of Ca V 1.2-Gal-1 coupling increased smooth muscle Ca V 1.2 currents, induced larger arterial contraction and caused hypertension in rats. In contrasting experiments, over-expression of Gal-1 in smooth muscle by a

  11. Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.

    PubMed

    Zeng, Wei-Fang; Kang, Yuan-Yuan; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2013-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor A&D UA-1020 with two different-shaped cuffs for home BP monitoring according to the British Hypertension Society (BHS) Protocol. We recruited individuals for each of the two cuffs (D-ring and cylindrical) until there were 85 eligible participants (255 pairs of comparisons) and their BP could meet the BP distribution requirements specified by the BHS Protocol. For each participant, we sequentially measured the systolic and diastolic BP using a mercury sphygmomanometer (two observers) and the UA-1020 device (one supervisor). For the D-ring cuff, the device achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 87, and 96%, respectively, for systolic BP, and 70, 90, and 99%, respectively, for diastolic BP. The average (±SD) of the device-observer differences was -0.2±7.3 mmHg (P=0.64) and 1.7±5.8 mmHg (P<0.0001) for systolic and diastolic BP, respectively. For the cylindrical cuff, the device also achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 88, and 97%, respectively, for systolic BP and 64, 89, and 98%, respectively, for diastolic BP. The average of the device-observer differences was -0.1±7.0 mmHg (P=0.89) and 2.0±6.3 mmHg (P<0.0001) for systolic and diastolic BP, respectively. The UA-1020 device has passed the requirements of the BHS Protocol with both the D-ring and the cylindrical cuffs, and hence can be recommended for home use in adults.

  12. Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG.

    PubMed

    Liu, Jing; Li, Yao; Ding, Xiao-Rong; Dai, Wen-Xuan; Zhang, Yuan-Ting

    2015-01-01

    Pulse transit time (PTT), which refers to the time it takes a pulse wave to travel between two arterial sites is a promising index for cuff-less blood pressure (BP) estimation, as well as non-invasive assessment of arterial functions. However, it has not been investigated whether PTTs measured from ECG and different wavelength PPG are equally affected by the arterial status. Furthermore, comparison between the changes of different PTTs can provide enlightenment on the hardware implementation of the PTT-based BP estimation method. This work mainly studied the changes of PTTs calculated from electrocardiogram (ECG) and multi-wavelength photoplethysmogram (PPG) after exerting cuff pressure on the upper arm. A four-channel PPG acquisition system was developed to collect the multi-wavelength PPG signals of red, yellow, green and blue light at the fingertip simultaneously. Ten subjects participated in the experiment and their PTTs measured from different PPG and ECG signals before and after exerting cuff pressure were compared. This study found that within one minute after the four-minute cuff inflation and deflation process, the PTT measured from ECG and yellow PPG experienced a significant increase (p<;0.05) while the PTT from ECG and blue PPG had no statistical difference (p>0.9) compared with that before exerting cuff pressure. This indicates that PTTs calculated from different wavelength PPG have different recoverability from smooth muscle relaxation. Another interesting finding is that the PTT calculated from ECG and yellow PPG had a strong correlation (|r|>0.7) with the time difference between yellow PPG and other PPG signals, which implies the potential of the time difference between yellow PPG and other PPGs as a complementary to PTT-based model for blood pressure estimation.

  13. Pressure and volume changes of tracheal tube cuff following inflation with various inflating agents during nitrous oxide anesthesia.

    PubMed

    Bajaj, Pramila; Nanda, Rajan; Goyal, Pradeep KR

    2004-10-01

    The study was designed to investigate the changes in pressure and volume of a tracheal tube-cuff inflated with air, mixture of N2O + O2, saline and 4% lidocaine during nitrous oxide anesthesia. This study was conducted in 80 patients (33 male & 47 female). The pressure and volume of a tracheal tube cuff increased with air, decreased with mixture of N2O + O2 and almost remained the same with saline and 4% lidocaine. The complications were more in the air group.

  14. Theoretical and practical knowledge of Nursing professionals on indirect blood pressure measurement at a coronary care unit

    PubMed Central

    Machado, Juliana Pereira; Veiga, Eugenia Velludo; Ferreira, Paulo Alexandre Camargo; Martins, José Carlos Amado; Daniel, Ana Carolina Queiroz Godoy; Oliveira, Amanda dos Santos; da Silva, Patrícia Costa dos Santos

    2014-01-01

    Objective To determine and to analyze the theoretical and practical knowledge of Nursing professionals on indirect blood pressure measurement. Methods This cross-sectional study included 31 professionals of a coronary care unit (86% of the Nursing staff in the unit). Of these, 38.7% of professionals were nurses and 61.3% nurse technicians. A validated questionnaire was used to theoretical evaluation and for practice assessment the auscultatory technique was applied in a simulation environment, under a non-participant observation. Results To the theoretical knowledge of the stages of preparation of patient and environment, 12.9% mentioned 5-minute of rest, 48.4% checked calibration, and 29.0% chose adequate cuff width. A total of 64.5% of professionals avoided rounding values, and 22.6% mentioned the 6-month deadline period for the equipment calibration. On average, in practice assessment, 65% of the steps were followed. Lacks in knowledge were primary concerning lack of checking the device calibration and stethoscope, measurement of arm circumference to choose the cuff size, and the record of arm used in blood pressure measurement. Conclusion Knowledge was poor and had disparities between theory and practice with evidence of steps taken without proper awareness and lack of consideration of important knowledge during implementation of blood pressure measurement. Educational and operational interventions should be applied systematically with institutional involvement to ensure safe care with reliable values. PMID:25295455

  15. Buffering of blood pressure variability by the renin-angiotensin system in the conscious dog

    PubMed Central

    Just, Armin; Kirchheim, Hartmut R; Ehmke, Heimo

    1998-01-01

    The renin-angiotensin system (RAS) participates in the compensation of major blood pressure disturbances such as haemorrhage and is involved in the tonic long-term (> 1 day) maintenance of mean arterial blood pressure (MABP). Since its contribution to the short-term (< 1 h) buffering of normal blood pressure variability is not known, this was investigated in resting conscious dogs.The regulatory efficiency and the response time of the RAS were studied by an acute step reduction of renal artery pressure to 70 mmHg for 1 h using a suprarenal aortic cuff. After a delay of at least 100 s, MABP rose exponentially by 22 ± 5 mmHg in normal dogs (n = 4), by 6 ± 3 mmHg after angiotensin converting enzyme (ACE) inhibition (n = 4), and by 25 ± 5 mmHg after ganglionic blockade (n = 4). MABP returned to control after release of the cuff with similar time courses. The time constants of the MABP responses were in the range of 20 min. Thus, possible feedback oscillations of the RAS would be expected around 0.0025 Hz (1/(4 × 100 s)); a buffering effect would be possible below this frequency.Blood pressure variability was investigated by spectral analysis of MABP from 3.75 h recordings in the frequency ranges of 0.002–0.003 Hz (feedback oscillations) and below 0.002 Hz (buffering effect).ACE inhibition (n = 7) decreased MABP by 11 ± 2 mmHg (P < 0.05), but in both frequency ranges integrated spectral density was not affected. ACE inhibition also failed to significantly change spectral density in either of the two frequency ranges under the following conditions: (1) during ganglionic blockade (n = 7), (2) during a low-sodium diet (except for a very slight elevation below 0.002 Hz) (n = 7), and (3) when the fall of MABP induced by ACE inhibition was compensated by an angiotensin II infusion (n = 7).It is concluded that in spite of its high regulatory efficiency with an adequate response time the RAS does not directly contribute to the short-term buffering of blood pressure

  16. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans

    PubMed Central

    Song, Bo Mi; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-01-01

    Background and Objectives We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. Subjects and Methods A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. Results The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Conclusion Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure. PMID:27275174

  17. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    NASA Technical Reports Server (NTRS)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p< 0.05. RESULTS: Artery diameter did not change from baseline. BF increased (p<0.05) after exercise in each condition except LBFR(sub SBP) in the order of HL (12.73+/-1.42 cm3,mean+/-SE) > LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of

  18. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats

    PubMed Central

    Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency

  19. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats.

    PubMed

    Wei, Shujie; Li, Dan; Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Radiofrequency-mediated perivascular RDN may become a

  20. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    PubMed

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  1. Assessment of Intraocular and Systemic Vasculature Pressure Parameters in Simulated Microgravity with Thigh Cuff Countermeasure

    NASA Technical Reports Server (NTRS)

    Huang, Alex S.; Balasubramanian, Siva; Tepelus, Tudor; Sadda, Jaya; Sadda, Srinivas; Stenger, Michael B.; Lee, Stuart M. C.; Laurie, Steve S.; Liu, John; Macias, Brandon R.

    2017-01-01

    Changes in vision have been well documented among astronauts during and after long-duration space flight. One hypothesis is that the space flight induced headward fluid alters posterior ocular pressure and volume and may contribute to visual acuity decrements. Therefore, we evaluated venoconstrictive thigh cuffs as a potential countermeasure to the headward fluid shift-induced effects on intraocular pressure (IOP) and cephalic vascular pressure and volumes.

  2. Blood pressure

    MedlinePlus

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  3. The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator.

    PubMed

    White, Donna M; Redondo, José I; Mair, Alastair R; Martinez-Taboada, Fernando

    2017-09-01

    The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator. Prospective, experimental clinical study. Participants included veterinary students at the beginning (group S1) and end (group S2) of their 2-week anaesthesia rotation and veterinary anaesthetists (group A). The feline airway simulator was designed to simulate an average size feline trachea, intubated with a 4.5 mm low-pressure, high-volume cuffed endotracheal tube, connected to a Bain breathing system with oxygen flow of 2 L minute -1 . Participants inflated the on-endotracheal tube cuff by pilot balloon palpation and by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during manual ventilation. Intracuff pressures were measured by manometers obscured to participants and ideally were 20-30 cm H 2 O. Student t, Fisher exact, and Chi-squared tests were used where appropriate to analyse data (p < 0.05). Participants were 12 students and eight anaesthetists. Measured intracuff pressures for palpation and MOV, respectively, were 19 ± 12 and 29 ± 19 cm H 2 O for group S1, 10 ± 5 and 20 ± 11 cm H 2 O for group S2 and 13 ± 6 and 29 ± 18 cm H 2 O for group A. All groups performed poorly at achieving intracuff pressures within the ideal range. There was no significant difference in intracuff pressures between techniques. Students administered lower (p = 0.02) intracuff pressures using palpation after their training. When using palpation and MOV for cuff inflation operators rarely achieved optimal intracuff pressures. Experience had no effect on this skill and, as such, a cuff manometer is recommended. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  4. Who's really hypertensive?--Quality control issues in the assessment of blood pressure for randomized trials.

    PubMed

    Reid, Christopher M; Ryan, Philip; Miles, Helen; Willson, Kristyn; Beilin, Laurence J; Brown, Mark A; Jennings, Garry L; Johnston, Colin I; Macdonald, Graham J; Marley, John E; McNeil, John J; Morgan, Trefor O; West, Malcolm J; Wing, Lindon M H

    2005-01-01

    The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study

  5. Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter

    NASA Astrophysics Data System (ADS)

    Zhang, Qiang; Chen, Xianxiang; Fang, Zhen; Xue, Yongjiao; Zhan, Qingyuan; Yang, Ting; Xia, Shanhong

    2017-02-01

    The present study designs an algorithm to increase the accuracy of continuous blood pressure (BP) estimation. Pulse arrival time (PAT) has been widely used for continuous BP estimation. However, because of motion artifact and physiological activities, PAT-based methods are often troubled with low BP estimation accuracy. This paper used a signal quality modified Kalman filter to track blood pressure changes. A Kalman filter guarantees that BP estimation value is optimal in the sense of minimizing the mean square error. We propose a joint signal quality indice to adjust the measurement noise covariance, pushing the Kalman filter to weigh more heavily on measurements from cleaner data. Twenty 2 h physiological data segments selected from the MIMIC II database were used to evaluate the performance. Compared with straightforward use of the PAT-based linear regression model, the proposed model achieved higher measurement accuracy. Due to low computation complexity, the proposed algorithm can be easily transplanted into wearable sensor devices.

  6. Effects of Concord grape juice on ambulatory blood pressure in prehypertension and stage 1 hypertension.

    PubMed

    Dohadwala, Mustali M; Hamburg, Naomi M; Holbrook, Monika; Kim, Brian H; Duess, Mai-Ann; Levit, Aaron; Titas, Megan; Chung, William B; Vincent, Felix B; Caiano, Tara L; Frame, Alissa A; Keaney, John F; Vita, Joseph A

    2010-11-01

    Consumption of flavonoid-containing foods may be useful for the management of hypertension. We investigated whether 100% Concord grape juice lowers blood pressure in patients with prehypertension and stage 1 hypertension. We conducted a double-blind crossover study to compare the effects of grape juice (7 mL · kg⁻¹ · d⁻¹) and matched placebo beverage on 24-h ambulatory blood pressure, stress-induced changes in blood pressure, and biochemical profile. Participants consumed each beverage for 8 wk with a 4-wk rest period between beverages. They ceased consumption of grapes and other flavonoid-containing beverages throughout the study. We enrolled 64 otherwise healthy patients taking no antihypertensive medications (31% women, 42% black, age 43 ± 12 y). Baseline mean (± SD) cuff blood pressure was 138 ± 7 (systolic)/82 ± 7 (diastolic) mm Hg. No effects on the primary endpoint of 24-h mean systolic blood pressure, diastolic blood pressure, or stress-induced changes in blood pressure were observed. A secondary endpoint was nocturnal dip in systolic pressure. At baseline, nocturnal pressure was 8.3 ± 7.1% lower at night than during daytime. The mean nocturnal dip increased 1.4 percentage points after grape juice and decreased 2.3 percentage points after placebo (P = 0.005). Fasting blood glucose was 91 ± 10 mg/dL at baseline for the entire cohort. Glucose decreased 2 mg/dL after consumption of grape juice and increased 1 mg/dL after consuming the placebo (P = 0.03). We observed no effect of grape juice on ambulatory blood pressure in this cohort of relatively healthy individuals with modestly elevated blood pressure. Secondary analyses suggested favorable effects on nocturnal dip and glucose homeostasis that may merit further investigation. This trial was registered at clinicaltrials.gov as NCT00302809.

  7. Efficacy and Safety of Using Air Versus Alkalinized 2% Lignocaine for Inflating Endotracheal Tube Cuff and Its Pressure Effects on Incidence of Postoperative Coughing and Sore Throat.

    PubMed

    Gaur, Pallavi; Ubale, Pravin; Khadanga, Prashant

    2017-01-01

    We wished to compare the endotracheal tube (ETT) cuff pressure inflated with air or alkalinized lignocaine during anesthesia and evaluate clinical symptoms such as coughing and sore throat (postoperative sore throat [POST]) following tracheal extubation. This was a prospective randomized controlled study conducted in a tertiary care set up over a period of 1 year. We included 100 patients in age group of 18-65 years posted for elective surgeries of duration more than 90 min under general anesthesia with N 2 O-O 2 mixture. Patients were randomized using computer-generated randomization table into air and lignocaine group. The ETT cuff was inflated with air or alkalinized lignocaine (2% lignocaine with 7.5% sodium bicarbonate, in the proportions of 19.0:1.0 ml) to the volume that prevented air leak using cuff pressure manometer. After extubation, an independent observer blinded to study group recorded the presence or absence of coughing and POST at immediately, 1 h and 24 h postoperatively. Demographic data, baseline characteristics (American Society of Anesthesiologists grade, intracuff volume/cuff pressure at start of surgery), and duration of anesthesia were comparable among study groups ( P > 0.05). Cuff pressure and volume achieved in the end of surgery were much higher in air group as compared to lignocaine group ( P < 0.05). Incidence of coughing and POST at immediately, 1 h and 24 h postoperatively was significantly higher in air group compared to lignocaine group. Impact of duration of anesthesia on rise in cuff pressure was significantly higher in air group and its effect on cuff-induced laryngotracheal morbidity was significant in both air and lignocaine group. This study showed the significance of use of alkalinized 2% lignocaine in prevention of rise of cuff pressure and incidence of coughing and POST. Duration of anesthesia has also a significant effect on incidence of postoperative trachea-laryngeal morbidity.

  8. A system for the automatic measurement and digital display of systolic and diastolic blood pressures

    NASA Technical Reports Server (NTRS)

    Schulze, A. E.

    1971-01-01

    Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.

  9. Older Women with Controlled Isolated Systolic Hypertension: Exercise and Blood Pressure.

    PubMed

    Ubolsakka-Jones, Chulee; Sangthong, Benjarat; Aueyingsak, Sahachat; Jones, David A

    2016-06-01

    Exercise is generally regarded as beneficial for health, but the consequent increases in blood pressure might pose a risk for hypertensive subjects. The purpose of this study was to determine blood pressure responses to dynamic exercise and sustained handgrip in patients with isolated systolic hypertension (ISH) who were stable on medication. Nineteen female ISH patients (66 ± 5 yr) and 19 age-matched normotensive (NT) female controls undertook a 5-min cycle exercise (60% heart rate reserve [HRR]) and a 2-min handgrip exercise (30% maximum voluntary contraction). Blood pressure responses were measured using an oscillometric cuff, together with heart rate and resting brachial pulse transit times. Systolic blood pressure (SBP) levels after cycle exercise were 194 ± 18 and 153 ± 19 mm Hg for ISH and NT, respectively, with the increase above resting being greater for ISH (P < 0.001), and only small changes were found in diastolic blood pressure (DBP). During handgrip exercise, SBP rose to 168 ± 19 and 140 ± 8 mm Hg for ISH and NT, respectively. The increases above baseline were greater for ISH both during the exercise and postexercise circulatory occlusion (P = 0.017). The increase in DBP levels during exercise and postexercise occlusion were similar in ISH and NT, suggesting little difference in metaboreflex sensitivity. Pulse transit time was shorter for ISH compared with NT (166 ± 6 ms and 242 ± 24 ms, respectively, P < 0.001), indicating stiffer arteries, which would increase SBP but not DBP. Despite being well controlled and normotensive control subjects at rest, ISH patients had high SBP responses to both dynamic and static exercises, which may constitute a risk for cardiovascular incidents.

  10. Control device for prosthetic urinary sphincter cuff

    NASA Technical Reports Server (NTRS)

    Reinicke, Robert H. (Inventor)

    1983-01-01

    A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.

  11. The impact of arm position on the measurement of orthostatic blood pressure.

    PubMed

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p < 0.0001). Arm position has a significant impact on determination of postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held

  12. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

    PubMed

    Poder, Thomas G; Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

  13. Effects of Concord grape juice on ambulatory blood pressure in prehypertension and stage 1 hypertension123

    PubMed Central

    Dohadwala, Mustali M; Hamburg, Naomi M; Holbrook, Monika; Kim, Brian H; Duess, Mai-Ann; Levit, Aaron; Titas, Megan; Chung, William B; Vincent, Felix B; Caiano, Tara L; Frame, Alissa A; Keaney, John F

    2010-01-01

    Background: Consumption of flavonoid-containing foods may be useful for the management of hypertension. Objective: We investigated whether 100% Concord grape juice lowers blood pressure in patients with prehypertension and stage 1 hypertension. Design: We conducted a double-blind crossover study to compare the effects of grape juice (7 mL · kg−1 · d−1) and matched placebo beverage on 24-h ambulatory blood pressure, stress-induced changes in blood pressure, and biochemical profile. Participants consumed each beverage for 8 wk with a 4-wk rest period between beverages. They ceased consumption of grapes and other flavonoid-containing beverages throughout the study. Results: We enrolled 64 otherwise healthy patients taking no antihypertensive medications (31% women, 42% black, age 43 ± 12 y). Baseline mean (±SD) cuff blood pressure was 138 ± 7 (systolic)/82 ± 7 (diastolic) mm Hg. No effects on the primary endpoint of 24-h mean systolic blood pressure, diastolic blood pressure, or stress-induced changes in blood pressure were observed. A secondary endpoint was nocturnal dip in systolic pressure. At baseline, nocturnal pressure was 8.3 ± 7.1% lower at night than during daytime. The mean nocturnal dip increased 1.4 percentage points after grape juice and decreased 2.3 percentage points after placebo (P = 0.005). Fasting blood glucose was 91 ± 10 mg/dL at baseline for the entire cohort. Glucose decreased 2 mg/dL after consumption of grape juice and increased 1 mg/dL after consuming the placebo (P = 0.03). Conclusions: We observed no effect of grape juice on ambulatory blood pressure in this cohort of relatively healthy individuals with modestly elevated blood pressure. Secondary analyses suggested favorable effects on nocturnal dip and glucose homeostasis that may merit further investigation. This trial was registered at clinicaltrials.gov as NCT00302809. PMID:20844075

  14. Sensitivity of two noninvasive blood pressure measurement techniques compared to telemetry in cynomolgus monkeys and beagle dogs.

    PubMed

    Mitchell, Andrea Z; McMahon, Carrie; Beck, Tom W; Sarazan, R Dustan

    2010-01-01

    Animals are commonly used in toxicological research for the evaluation of drug effects on the cardiovascular system. Accurate and reproducible determination of blood pressure (BP) in conscious, manually restrained monkeys and dogs is a challenge with current non-invasive cuff techniques. The High Definition Oscillometry (HDO) technique enables real time measurements with immediate visual feedback via PC screen on data validity. HDO measurements are considerably faster with a duration of approximately 8 to 15s than conventional cuff methods that can take several minutes. HDO Memo Diagnostic Model Science and Cardell BP Monitor Model 9401 measurements were compared for accuracy and reliability with simultaneously recorded direct blood pressure data captured via radiotelemetry. Six monkeys and six dogs implanted with DSI PCT telemetry transmitters were used; BP data were collected by all methods under manual constraint and compared. Measurements were performed with HDO and Cardell in the presence of a BP lowering drug (hexamethonium bromide). Systolic, diastolic, mean arterial pressure, and pulse rate were determined before, during and following up to 10mg/kg hexamethonium administration via intravenous slow bolus injection. Drug induced hemodynamic changes could be detected in monkeys and dogs with the HDO method but only in dogs with the Cardell method. Correlation coefficients were generally higher for HDO versus Telemetry than Cardell versus Telemetry comparisons, indicating that this novel, non-invasive technique produces reliable blood pressure data and is able to detect drug-induced hemodynamic changes. HDO provides an alternative approach for invasive telemetry surgeries to obtain reliable hemodynamic data in animal models for cardiovascular research when invasive techniques are not warranted. Copyright 2010 Elsevier Inc. All rights reserved.

  15. [Analysis on risk factors of endotracheal cuff under inflation in mechanically ventilated patients].

    PubMed

    Fu, You; Xi, Xiuming

    2014-12-01

    To investigate the prevalent condition of endotracheal cuff pressure and risk factors for under inflation. A prospective cohort study was conducted. Patients admitted to the Department of Critical Care Medicine of Fuxing Hospital Affiliated to Capital Medical University, who were intubated with a high-volume low-pressure endotracheal tube, and had undergone mechanical ventilation for at least 48 hours, were enrolled. The endotracheal cuff pressure was determined every 8 hours by a manual manometer connected to the distal edge of the valve cuff at 07 : 00, 15 : 00, and 23 : 00. Measurement of the endotracheal cuff pressure was continued until the extubation of endotracheal or tracheostomy tube, or death of the patient. According to the incidence of under inflation of endotracheal cuff, patients were divided into the incidence of under inflation lower than 25% group (lower low cuff pressure group) and higher than 25% group (higher low cuff pressure group). The possible influencing factors were evaluated in the two groups, including body mass index (BMI), size of endotracheal tube, duration of intubation, use of sedative or analgesic, number of leaving from intensive care unit (ICU), the number of turning over the patients, and aspiration of sputum. Logistic regression analysis was used to determine risk factors for under-inflation of the endotracheal cuff. During the study period, 53 patients were enrolled. There were 812 measurements, and 46.3% of them was abnormal, and 204 times (25.1%) of under inflation of endotracheal cuff were found. There were 24 patients (45.3%) in whom the incidence of under inflation rate was higher than 25%. The average of under inflation was 7 (4, 10) times. Compared with the group with lower rate of low cuff pressure, a longer time for intubation was found in group with higher rate of low cuff pressure [hours: 162 (113, 225) vs. 118 (97, 168), Z=-2.034, P=0.042]. There were no differences between the two groups in other factors

  16. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia

    PubMed Central

    Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K.; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Background Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Methods Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. Results We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. Conclusion To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia. PMID:27711116

  17. A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

    NASA Astrophysics Data System (ADS)

    Scardulla, Francesco; Hu, Sijung; D'Acquisto, Leonardo; Pasta, Salvatore; Barrett, Laura; Blanos, Panagiotis; Yan, Liangwen

    2018-02-01

    In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 +/- 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with increases of +10mmHg and subsequently deflated by 10mmHg until reaching full deflation. The OEPS signals were captured using four wavelength illumination sources (i.e., green 525 nm, orange 595 nm, red 650 nm and IR 870 nm) on three different measuring sites, namely forefinger, radial artery and wrist. The implemented algorithm provides information on the instant when the SBP was reached and the signal is lost since the vessel is completely blocked. Similarly, it detected the signal resumption when the external pressure dropped below the SBP. The findings demonstrated a good correlation between the variation of the pressure and the corresponding OEPS signal with the most accurate result achieved in the fingertip among all wavelengths, with a temporal identification error of 8.07 %. Further studies will improve the clinical relevance on a cohort of patients diagnosed with hyper- or hypotension, in order to develop a wearable blood-pressure device.

  18. Low Blood Pressure

    MedlinePlus

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  19. Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population.

    PubMed

    Grover-Páez, Fernando; Cardona-Muñoz, Ernesto G; Cardona-Müller, David; Guzmán-Saldívar, Víctor H; Rodríguez-De la Cerda, Mariana; Jiménez-Cázarez, Mayra B; Totsuka-Sutto, Sylvia E; Alanis-Sánchez, Guillermo A; Ramos-Becerra, Carlos G

    2017-12-01

    The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.

  20. Continuous versus intermittent endotracheal cuff pressure control for the prevention of ventilator-associated respiratory infections in Vietnam: study protocol for a randomised controlled trial.

    PubMed

    Dat, Vu Quoc; Geskus, Ronald B; Wolbers, Marcel; Loan, Huynh Thi; Yen, Lam Minh; Binh, Nguyen Thien; Chien, Le Thanh; Mai, Nguyen Thi Hoang; Phu, Nguyen Hoan; Lan, Nguyen Phu Huong; Hao, Nguyen Van; Long, Hoang Bao; Thuy, Tran Phuong; Kinh, Nguyen Van; Trung, Nguyen Vu; Phu, Vu Dinh; Cap, Nguyen Trung; Trinh, Dao Tuyet; Campbell, James; Kestelyn, Evelyne; Wertheim, Heiman F L; Wyncoll, Duncan; Thwaites, Guy Edward; van Doorn, H Rogier; Thwaites, C Louise; Nadjm, Behzad

    2018-04-04

    Ventilator-associated respiratory infection (VARI) comprises ventilator-associated pneumonia (VAP) and ventilator-associated tracheobronchitis (VAT). Although their diagnostic criteria vary, together these are the most common hospital-acquired infections in intensive care units (ICUs) worldwide, responsible for a large proportion of antibiotic use within ICUs. Evidence-based strategies for the prevention of VARI in resource-limited settings are lacking. Preventing the leakage of oropharyngeal secretions into the lung using continuous endotracheal cuff pressure control is a promising strategy. The aim of this study is to investigate the efficacy of automated, continuous endotracheal cuff pressure control in preventing the development of VARI and reducing antibiotic use in ICUs in Vietnam. This is an open-label randomised controlled multicentre trial. We will enrol 600 adult patients intubated for ≤ 24 h at the time of enrolment. Eligible patients will be stratified according to admission diagnosis (180 tetanus, 420 non-tetanus) and site and will be randomised in a 1:1 ratio to receive either (1) automated, continuous control of endotracheal cuff pressure or (2) intermittent measurement and control of endotracheal cuff pressure using a manual cuff pressure meter. The primary outcome is the occurrence of VARI, defined as either VAP or VAT during the ICU admission up to a maximum of 90 days after randomisation. Patients in both groups who are at risk for VARI will receive a standardised battery of investigations if their treating physician feels a new infection has occurred, the results of which will be used by an endpoint review committee, blinded to the allocated arm and independent of patient care, to determine the primary outcome. All enrolled patients will be followed for mortality and endotracheal tube cuff-related complications at 28 days and 90 days after randomisation. Other secondary outcomes include antibiotic use; days ventilated, in ICU and in hospital

  1. [Blood pressure measurement].

    PubMed

    Bang, Lia Evi; Wiinberg, Niels

    2009-06-08

    Blood pressure measurement should follow recommended procedures, otherwise incorrect diagnoses will follow resulting in incorrect treatment and cardiovascular events. The standard for clinical blood pressure measurement is the auscultatory method, but mercury sphygmomanometers can still be used. Blood pressure measurement at home using 24-hour or home blood pressure has documented a better reproducibility and predicts cardiovascular event more precisely than clinic blood pressure. 24-hour measurement or home blood pressure measurement should be performed in patients with suspected hypertension without hypertensive organ damage to reveal white-coat hypertension.

  2. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm with the patient supine or with the head of the bed raised 45 degrees: a follow-up study.

    PubMed

    Schell, Kathleen; Lyons, Denise; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Wakai, Sandra; Carson, Elizabeth; Waterhouse, Julie; Chichester, Melanie; Bartell, Deborah; Foraker, Theresa; Simpson, E Kathleen

    2006-03-01

    Noninvasive measurement of blood pressure in the forearm is used when the upper arm is inaccessible and/or when available blood pressure cuffs do not fit a patient's arm. Evidence supporting this practice is limited. To compare noninvasive measurements of blood pressure in the forearm and upper arm of medical-surgical inpatients positioned supine and with the head of the bed raised 45 degrees . Cuff size was selected on the basis of forearm and upper arm circumference and manufacturers' recommendations. With a Welch Allyn Vital Signs 420 Series monitor, blood pressures were measured in the forearm and then in the upper arm of 221 supine patients with their arms resting at their sides. Patients were repositioned with the head of the bed elevated 45 degrees and after 2 minutes, blood pressures were measured in the upper arm and then the forearm. Starting position was alternated on subsequent subjects. Paired t tests revealed significant differences between systolic and diastolic blood pressures measured in the upper arm and forearm with patients supine and with the head of the bed elevated 45 degrees . The Bland-Altman procedure revealed that the distances between the mean values and the limits of agreement were from 15 to 33 mm Hg for individual subjects. Noninvasive measurements of blood pressure in the forearm and upper arm cannot be interchanged in medical-surgical patients who are supine or in patients with the head of the bed elevated 45 degrees .

  3. Validation of the Omron MIT Elite blood pressure device in a pregnant population with large arm circumference.

    PubMed

    James, Lauren; Nzelu, Diane; Hay, Anna; Shennan, Andrew; Kametas, Nikos A

    2017-04-01

    The aim of this study was to evaluate the accuracy of the Omron MIT Elite automated device in pregnant women with an arm circumference of or above 32 cm, using the British Hypertension Society validation protocol. Blood pressure was measured sequentially in 46 women of any gestation requiring the use of a large cuff (arm circumference ≥32 cm) alternating between the mercury sphygmomanometer and the Omron MIT Elite device. The Omron MIT Elite achieved an overall D/D grade with a mean of the device-observer difference being 7.17±6.67 and 9.31±6.59 for systolic and diastolic blood pressure respectively. Interobserver accuracy was 94.6% for systolic and 95% for diastolic readings within 5 mmHg. The Omron MIT Elite overestimates blood pressure and has failed the British Hypertension Society protocol requirements. Therefore, it cannot be recommended for use in pregnant women with an arm circumference of or above 32 cm.

  4. Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe use without cuff manometer in adults.

    PubMed

    Kim, Min-Soo; Lee, Jeong-Rim; Shin, Yang-Sik; Chung, Ji-Won; Lee, Kyu-Ho; Ahn, Ki Ryang

    2014-03-01

    This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device. Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion. The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 ± 16.1 cm H2O vs 61.8 ± 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation. The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures

    PubMed Central

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-01-01

    Purpose Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. Methods A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland–Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. Results The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland–Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. Conclusions The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. PMID:27422970

  6. Assessment of sequential same arm agreement of blood pressure measurements by a CVProfilor DO-2020 versus a Baumanometer mercury sphygmomanometer.

    PubMed

    Prisant, L M; Resnick, L M; Hollenberg, S M

    2001-06-01

    The aim of this study was to assess the accuracy of sequential same arm blood pressure measurement by the mercury sphygmomanometer with the oscillometric blood pressure measurements from a device that also determines arterial elasticity. A prospective, multicentre, clinical study evaluated sequential same arm blood pressure measurements, using a mercury sphygmomanometer (Baumanometer, W. A. Baum Co., Inc., Copiague, New York, USA) and an oscillometric non-invasive device that calculates arterial elasticity (CVProfilor DO-2020 Cardiovascular Profiling System, Hypertension Diagnostics, Inc., Eagan, Minnesota, USA). Blood pressure was measured supine in triplicate, 3 min apart in a randomized sequence after a period of rest. The study population of 230 normotensive and hypertensive subjects included 57% females, 51% Caucasians, and 33% African Americans. The mean difference between test methods of systolic blood pressure, diastolic blood pressure, and heart rate was -3.2 +/- 6.9 mmHg, +0.8 +/- 5.9 mmHg, and +1.0 +/- 5.7 beats/minute. For systolic and diastolic blood pressure, 60.9 and 70.4% of sequential measurements by each method were within +/- 5 mmHg. Few or no points fell beyond the mean +/- 2 standard deviations lines for each cuff bladder size. Sequential same arm measurements of the CVProfilor DO-2020 Cardiovascular Profiling System measures blood pressure by an oscillometric method (dynamic linear deflation) with reasonable agreement with a mercury sphygmomanometer.

  7. A computational model of the cardiovascular system coupled with an upper-arm oscillometric cuff and its application to studying the suprasystolic cuff oscillation wave, concerning its value in assessing arterial stiffness.

    PubMed

    Liang, Fuyou; Takagi, Shu; Himeno, Ryutaro; Liu, Hao

    2013-01-01

    A variety of methods have been proposed to noninvasively assess arterial stiffness using single or multiple oscillometric cuffs. A common pitfall of most of such methods is that the individual-specific accuracy of assessment is not clearly known due to an insufficient understanding of the relationships between the characteristics of cuff oscillometry and cardiovascular properties. To provide a tool for quantitatively investigating such relationships, we developed a computational model of the cardiovascular system coupled with an oscillometric cuff wrapped around the left upper arm. The model was first examined by simulating the inflation-deflation process of the cuff. The simulated results reasonably reproduced the well-established characteristics of cuff oscillometry. The model was then applied to study the oscillation wave generated by a suprasystolic cuff that is currently under considerable debate regarding its validity for assessing aortic stiffness. The simulated results confirmed the experimental observations that the suprasystolic cuff oscillation wave resembles the blood pressure wave in the proximal brachial artery and is characterised by the presence of two systolic peaks. A systemic analysis on the simulation results for various cardiovascular/physiological conditions revealed that neither the time lag nor the height difference between the two peaks is a direct indicator of aortic stiffness. These findings provided useful evidence for explaining the conflicts among previous studies. Finally, it was stressed that although the emphasis of this study has been placed on a suprasystolic upper-arm cuff, the model could be employed to address more issues related to oscillometric cuffs.

  8. Acute increases in arterial blood pressure produced by occlusion of the abdominal aorta induces antinociception: peripheral and central substrates.

    PubMed

    Thurston, C L; Randich, A

    1990-06-11

    Occlusion of the abdominal aorta proximal to the renal arteries results in an increase in arterial blood pressure, inhibition of forepaw and hindpaw withdrawal to a noxious mechanical stimulus, and inhibition of the tail-flick reflex to noxious heat. Occlusion of the abdominal aorta distal to the renal arteries does not elevate arterial blood pressure and produces no antinociceptive effects. Occlusion of the vena cava lowers arterial blood pressure and produces no antinociception. The inhibitory effects of occlusion of the abdominal aorta depend upon activation of high pressure baroreceptors since bilateral sinoaortic denervation, but not bilateral vagotomy, eliminates the inhibition with respect to all behavioral measures. The inhibitory effects with respect to the tail-flick reflex also depend upon activation of a descending inhibitory system since reversible cold block of the spinal cord at the level of the second thoracic vertebra eliminates the antinociception. This antinociception is also eliminated following intrathecal administration of the noradrenergic receptor antagonist phentolamine, but not by intrathecal administration of either methysergide or naloxone. These data support the view that activation of high pressure baroreceptors by increases in arterial blood pressure produces antinociception via activation of a spinopetal noradrenergic system.

  9. Cuff-Based Oscillometric Central and Brachial Blood Pressures Obtained Through ABPM are Similarly Associated with Renal Organ Damage in Arterial Hypertension.

    PubMed

    Fernández-Llama, Patricia; Pareja, Júlia; Yun, Sergi; Vázquez, Susana; Oliveras, Anna; Armario, Pedro; Blanch, Pedro; Calero, Francesca; Sierra, Cristina; de la Sierra, Alejandro

    2017-01-01

    Central blood pressure (BP) has been suggested to be a better estimator of hypertension-associated risks. We aimed to evaluate the association of 24-hour central BP, in comparison with 24-hour peripheral BP, with the presence of renal organ damage in hypertensive patients. Brachial and central (calculated by an oscillometric system through brachial pulse wave analysis) office BP and ambulatory BP monitoring (ABPM) data and aortic pulse wave velocity (PWV) were measured in 208 hypertensive patients. Renal organ damage was evaluated by means of the albumin to creatinine ratio and the estimated glomerular filtration rate. Fifty-four patients (25.9%) were affected by renal organ damage, displaying either microalbuminuria (urinary albumin excretion ≥30 mg/g creatinine) or an estimated glomerular filtration rate (eGFR) <60 ml/min/1.73 m2. Compared to those without renal abnormalities, hypertensive patients with kidney damage had higher values of office brachial systolic BP (SBP) and pulse pressure (PP), and 24-h, daytime, and nighttime central and brachial SBP and PP. They also had a blunted nocturnal decrease in both central and brachial BP, and higher values of aortic PWV. After adjustment for age, gender, and antihypertensive treatment, only ABPM-derived BP estimates (both central and brachial) showed significant associations with the presence of renal damage. Odds ratios for central BP estimates were not significantly higher than those obtained for brachial BP. Compared with peripheral ABPM, cuff-based oscillometric central ABPM does not show a closer association with presence of renal organ damage in hypertensive patients. More studies, however, need to be done to better identify the role of central BP in clinical practice. © 2017 The Author(s). Published by S. Karger AG, Basel.

  10. Forearm and upper-arm oscillometric blood pressure comparison in acutely ill adults.

    PubMed

    Schell, Kathleen; Morse, Kate; Waterhouse, Julie K

    2010-04-01

    When patients' upper arms are not accessible and/or when cuffs do not fit large upper arms, the forearm site is often used for blood pressure (BP) measurement. The purpose of this study is to compare forearm and upper-arm BPs in 70 acutely ill adults, admitted to a community hospital's 14-bed ICU. Using Philips oscillometric monitors, three repeated measures of forearm and upper-arm BPs are obtained with head of bed flat and with head of bed elevated at 30 degrees. Arms are resting on the bed. Paired t tests show statistically significant differences in systolic BPs, diastolic BPs, and mean arterial pressures in the supine and head-elevated positions. Bland-Altman analyses indicate that forearm and upper-arm oscillometric BPs are not interchangeable in acutely ill adults.

  11. Muscle Sympathetic Nerve Activity During Intense Lower Body Negative Pressure to Presyncope in Humans

    DTIC Science & Technology

    2009-08-24

    frequency rhythms. Arterial pressure oscillations increase with reductions in central blood volume induced by haemorrhage (Guyton & Harris, 1951), head...a finger cuff to record beat-by-beat finger arterial pressure (Finometer Blood Pressure Monitor, TNO-TPD Biomedical Instrumentation, Amsterdam, The...experienced reductions in arterial pressure at presyncope. The lowest blood pressures recorded for each subject are shown in the upper right of each

  12. Diurnal blood pressure changes.

    PubMed

    Asayama, Kei; Satoh, Michihiro; Kikuya, Masahiro

    2018-05-23

    The definition of diurnal blood pressure changes varies widely, which can be confusing. Short-term blood pressure variability during a 24-h period and the dipping status of diurnal blood pressure can be captured by ambulatory blood pressure monitoring, and these metrics are reported to have prognostic significance for cardiovascular complications. Morning blood pressure surge also indicates this risk, but its effect may be limited to populations with specific conditions. Meanwhile, the combined use of conventional office blood pressure and out-of-office blood pressure allows us to identify people with white-coat and masked hypertension. Current home devices can measure nocturnal blood pressure during sleep more conveniently than ambulatory monitoring; however, we should pay attention to blood pressure measurement conditions regardless of whether they are in a home, ambulatory, or office setting. The relatively poor reproducibility of diurnal blood pressure changes, including the nocturnal fall of blood pressure, is another underestimated issue to be addressed. Although information on diurnal blood pressure changes is expected to be used more effectively in the future, we should also keep in mind that blood pressure levels have remained central to the primary and secondary prevention of blood pressure-related cardiovascular diseases in clinical practice.

  13. Normalization of Blood Pressure With Spinal Cord Epidural Stimulation After Severe Spinal Cord Injury

    PubMed Central

    Harkema, Susan J.; Wang, Siqi; Angeli, Claudia A.; Chen, Yangsheng; Boakye, Maxwell; Ugiliweneza, Beatrice; Hirsch, Glenn A.

    2018-01-01

    Chronic low blood pressure and orthostatic hypotension remain challenging clinical issues after severe spinal cord injury (SCI), affecting health, rehabilitation, and quality of life. We previously reported that targeted lumbosacral spinal cord epidural stimulation (scES) could promote stand and step functions and restore voluntary movement in patients with chronic motor complete SCI. This study addresses the effects of targeted scES for cardiovascular function (CV-scES) in individuals with severe SCI who suffer from chronic hypotension. We tested the hypothesis that CV-scES can increase resting blood pressure and attenuate chronic hypotension in individuals with chronic cervical SCI. Four research participants with chronic cervical SCI received an implant of a 16-electrode array on the dura (L1–S1 cord segments, T11–L1 vertebrae). Individual-specific CV-scES configurations (anode and cathode electrode selection, voltage, frequency, and pulse width) were identified to maintain systolic blood pressure within targeted normative ranges without skeletal muscle activity of the lower extremities as assessed by electromyography. These individuals completed five 2-h sessions using CV-scES in an upright, seated position during measurement of blood pressure and heart rate. Noninvasive continuous blood pressure was measured from a finger cuff by plethysmograph technique. For each research participant there were statistically significant increases in mean arterial pressure in response to CV-scES that was maintained within normative ranges. This result was reproducible over the five sessions with concomitant decreases or no changes in heart rate using individual-specific CV-scES that was modulated with modest amplitude changes throughout the session. Our study shows that stimulating dorsal lumbosacral spinal cord can effectively and safely activate mechanisms to elevate blood pressures to normal ranges from a chronic hypotensive state in humans with severe SCI with

  14. Tendon–bone contact pressure and biomechanical evaluation of a modified suture-bridge technique for rotator cuff repair

    PubMed Central

    Geyer, Michael; Büschken, Meike; Buchhorn, Gottfried H.; Spahn, Gunter; Klinger, Hans-Michael

    2009-01-01

    The aim of the study was to evaluate the time-zero mechanical and footprint properties of a suture-bridge technique for rotator cuff repair in an animal model. Thirty fresh-frozen sheep shoulders were randomly assigned among three investigation groups: (1) cyclic loading, (2) load-to-failure testing, and (3) tendon–bone interface contact pressure measurement. Shoulders were cyclically loaded from 10 to 180 N and displacement to gap formation of 5- and 10-mm at the repair site. Cycles to failure were determined. Additionally, the ultimate tensile strength and stiffness were verified along with the mode of failure. The average contact pressure and pressure pattern were investigated using a pressure-sensitive film system. All of the specimens resisted against 3,000 cycles and none of them reached a gap formation of 10 mm. The number of cycles to 5-mm gap formation was 2,884.5 ± 96.8 cycles. The ultimate tensile strength was 565.8 ± 17.8 N and stiffness was 173.7 ± 9.9 N/mm. The entire specimen presented a unique mode of failure as it is well known in using high strength sutures by pulling them through the tendon. We observed a mean contact pressure of 1.19 ± 0.03 MPa, applied on the footprint area. The fundamental results of our study support the use of a suture-bridge technique for optimising the conditions of the healing biology of a reconstructed rotator cuff tendon. Nevertheless, an individual estimation has to be done if using the suture-bridge technique clinically. Further investigation is necessary to evaluate the cell biological healing process in order to achieve further sufficient advancements in rotator cuff repair. PMID:19826786

  15. Towards development of a mobile RF Doppler sensor for continuous heart rate variability and blood pressure monitoring.

    PubMed

    Insoo Kim; Bhagat, Yusuf A

    2016-08-01

    The standard in noninvasive blood pressure (BP) measurement is an inflatable cuff device based on the oscillometric method, which poses several practical challenges for continuous BP monitoring. Here, we present a novel ultra-wide band RF Doppler radar sensor for next-generation mobile interface for the purpose of characterizing fluid flow speeds, and for ultimately measuring cuffless blood flow in the human wrist. The system takes advantage of the 7.1~10.5 GHz ultra-wide band signals which can reduce transceiver complexity and power consumption overhead. Moreover, results obtained from hardware development, antenna design and human wrist modeling, and subsequent phantom development are reported. Our comprehensive lab bench system setup with a peristaltic pump was capable of characterizing various speed flow components during a linear velocity sweep of 5~62 cm/s. The sensor holds potential for providing estimates of heart rate and blood pressure.

  16. Biceps-Related Physical Findings Are Useful to Prevent Misdiagnosis of Cervical Spondylotic Amyotrophy as a Rotator Cuff Tear.

    PubMed

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Yamamoto, Yusuke; Sakamoto, Yoshihiro; Koizumi, Munehisa; Tanaka, Yasuhito

    2018-02-01

    Case-control study. The aim of the present study was to identify physical findings useful for differentiating between cervical spondylotic amyotrophy (CSA) and rotator cuff tears to prevent the misdiagnosis of CSA as a rotator cuff tear. CSA and rotator cuff tears are often confused among patients presenting with difficulty in shoulder elevation. Twenty-five patients with CSA and 27 with rotator cuff tears were enrolled. We included five physical findings specific to CSA that were observed in both CSA and rotator cuff tear patients. The findings were as follows: (1) weakness of the deltoid muscle, (2) weakness of the biceps muscle, (3) atrophy of the deltoid muscle, (4) atrophy of the biceps muscle, and (5) swallow-tail sign (assessment of the posterior fibers of the deltoid). Among 25 CSA patients, 10 (40.0%) were misdiagnosed with a rotator cuff tear on initial diagnosis. The sensitivity and specificity of each physical finding were as follows: (1) deltoid weakness (sensitivity, 92.0%; specificity, 55.6%), (2) biceps weakness (sensitivity, 80.0%; specificity, 100%), (3) deltoid atrophy (sensitivity, 96.0%; specificity, 77.8%), (4) biceps atrophy (sensitivity, 88.8%; specificity, 92.6%), and (5) swallow-tail sign (sensitivity, 56.0%; specificity, 74.1%). There were statistically significant differences in each physical finding. CSA is likely to be misdiagnosed as a rotator cuff tear; however, weakness and atrophy of the biceps are useful findings for differentiating between CSA and rotator cuff tears to prevent misdiagnosis.

  17. Leakage of fluid around endotracheal tube cuffs: a cadaver study

    PubMed Central

    Lucius, Ralph; Ewald, Kristian

    2013-01-01

    Background The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Methods Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. Results The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. Conclusions The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required. PMID:24363847

  18. Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.

    PubMed

    Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep

    2014-01-01

    A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.

  19. Brachial cuff measurements of blood pressure during passive leg raising for fluid responsiveness prediction.

    PubMed

    Lakhal, K; Ehrmann, S; Benzekri-Lefèvre, D; Runge, I; Legras, A; Dequin, P-F; Mercier, E; Wolff, M; Régnier, B; Boulain, T

    2012-05-01

    The passive leg raising maneuver (PLR) for fluid responsiveness testing relies on cardiac output (CO) measurements or invasive measurements of arterial pressure (AP) whereas the initial hemodynamic management during shock is often based solely on brachial cuff measurements. We assessed PLR-induced changes in noninvasive oscillometric readings to predict fluid responsiveness. Multicentre interventional study. In ICU sedated patients with circulatory failure, AP (invasive and noninvasive readings) and CO measurements were performed before, during PLR (trunk supine, not modified) and after 500-mL volume expansion. Areas under the ROC curves (AUC) were determined for fluid responsiveness (>10% volume expansion-induced increase in CO) prediction. In 112 patients (19% with arrhythmia), changes in noninvasive systolic AP during PLR (noninvasiveΔ(PLR)SAP) only predicted fluid responsiveness (cutoff 17%, n=21, positive likelihood ratio [LR] of 26 [18-38]), not unresponsiveness. If PLR-induced change in central venous pressure (CVP) was at least of 2 mm Hg (n=60), suggesting that PLR succeeded in altering cardiac preload, noninvasiveΔ(PLR)SAP performance was good: AUC of 0.94 [0.85-0.98], positive and negative LRs of 5.7 [4.6-6.8] and 0.07 [0.009-0.5], respectively, for a cutoff of 9%. Of note, invasive AP-derived indices did not outperform noninvasiveΔ(PLR)SAP. Regardless of CVP (i.e., during "blind PLR"), noninvasiveΔ(PLR)SAP more than 17% reliably identified fluid responders. During "CVP-guided PLR", in case of sufficient change in CVP, noninvasiveΔ(PLR)SAP performed better (cutoff of 9%). These findings, in sedated patients who had already undergone volume expansion and/or catecholamines, have to be verified during the early phase of circulatory failure (before an arterial line and/or a CO measuring device is placed). Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  20. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    PubMed

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-08-01

    Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. High Blood Pressure

    MedlinePlus

    ... normal blood pressure 140/90 or higher is high blood pressure Between 120 and 139 for the top number, ... prehypertension. Prehypertension means you may end up with high blood pressure, unless you take steps to prevent it. High ...

  2. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.

    PubMed

    Chenelle, Christopher T; Itagaki, Taiga; Fisher, Daniel F; Berra, Lorenzo; Kacmarek, Robert M

    2017-01-01

    Cuff design affects microaspiration, a risk factor for pneumonia. We questioned whether the PneuX low-volume fold-free cuff design would prevent cuff leakage and maintain the same tracheal wall pressure as high-volume, low-pressure (HVLP) cuffs. We evaluated 4 HVLP-cuffed endotracheal tubes (ETTs), Hi-Lo (polyvinyl chloride [PVC]), Microcuff (polyurethane [PU]), SealGuard (PU + tapered), and TaperGuard (PVC + tapered), and the PneuX with its dedicated tracheal seal monitor. In Part 1, we determined tracheal wall pressure using each cuff's capacity to support water columns across recommended intracuff pressures. In Part 2, we evaluated the tracheal seal monitor function at recommended settings. In Part 3, we compared leakage volumes of all ETTs during 30 min of simulated mechanical ventilation or during 8 h if no leak occurred. Parts 1 and 3 were performed with/without lubrication and PEEP. In Part 1, PneuX cuffs exerted an average tracheal wall pressure of 27.4 ± 2.4 cm H 2 O at the recommended intracuff pressure of approximately 80 cm H 2 O. Tracheal wall pressure did not differ among HVLP cuffs (19.6 ± 1.4 to 29.5 ± 1.4 cm H 2 O). In Part 2, preinflation intracuff pressure affected the time to obtain tracheal seal monitor pressure attainment (P < .01). The tracheal seal monitor generated average calculated tracheal wall pressure of 33.4 ± 1.2 cm H 2 O. In Part 3, PneuX ETT showed no leak across 8 h for all trials. Overall, leakage volume was lower with PU (P < .01) and PneuX (P < .01) than with PVC cuffs, regardless of shape, and lower with lubrication and/or PEEP (all P < .01). In each HVLP cuff, lubrication alone eliminated leak at an intracuff pressure of ≤30 cm H 2 O. The PneuX cuff generally exerted acceptable tracheal wall pressure, but the tracheal wall pressure monitor allowed pressures exceeding 30 cm H 2 O in some trials and was the only ETT to prevent leak in all tests. For HVLP cuffs, leak was reduced by PU and PEEP and eliminated by lubrication

  3. The Pressure Distribution over the Horizontal Tail Surfaces of an Airplane III

    NASA Technical Reports Server (NTRS)

    Norton, F H; Brown, W G

    1923-01-01

    This report contains the results of an investigation of the distribution of pressure over the tail surfaces of a full-sized airplane during accelerated flight for the purpose of determining the magnitude of the tail and fuselage stresses in maneuvering. As the pressures in accelerated flight change in value with great rapidity, it was found that the liquid manometer used in the first part of this investigation would not be at all suitable under these conditions; so it was necessary to design and construct a new manometer containing a large number of recording diaphragm gauges for these measurements. Sixty openings on the tail surfaces were connected to this manometer and continuous records of pressures for each pair of holes were taken during various maneuvers. There were also recorded, simultaneously with the pressures, the normal acceleration at the center of gravity and the angular position of all the controls. The present investigation consisted in measuring on a standard rigged JN4H airplane the distribution of pressure over the whole of the horizontal tail surfaces while the airplane was being put through maneuvers as violently as it was thought safe, including spinning and pulling out of dives.

  4. Blood pressure variability of two ambulatory blood pressure monitors.

    PubMed

    Kallem, Radhakrishna R; Meyers, Kevin E C; Cucchiara, Andrew J; Sawinski, Deirdre L; Townsend, Raymond R

    2014-04-01

    There are no data on the evaluation of blood pressure (BP) variability comparing two ambulatory blood pressure monitoring monitors worn at the same time. Hence, this study was carried out to compare variability of BP in healthy untreated adults using two ambulatory BP monitors worn at the same time over an 8-h period. An Accutorr device was used to measure office BP in the dominant and nondominant arms of 24 participants.Simultaneous 8-h BP and heart rate data were measured in 24 untreated adult volunteers by Mobil-O-Graph (worn for an additional 16 h after removing the Spacelabs monitor) and Spacelabs with both random (N=12) and nonrandom (N=12) assignment of each device to the dominant arm. Average real variability (ARV), SD, coefficient of variation, and variation independent of mean were calculated for systolic blood pressure, diastolic blood pressure, mean arterial pressure, and pulse pressure (PP). Whether the Mobil-O-Graph was applied to the dominant or the nondominant arm, the ARV of mean systolic (P=0.003 nonrandomized; P=0.010 randomized) and PP (P=0.009 nonrandomized; P=0.005 randomized) remained significantly higher than the Spacelabs device, whereas the ARV of the mean arterial pressure was not significantly different. The average BP readings and ARVs for systolic blood pressure and PP obtained by the Mobil-O-Graph were considerably higher for the daytime than the night-time. Given the emerging interest in the effect of BP variability on health outcomes, the accuracy of its measurement is important. Our study raises concerns about the accuracy of pooling international ambulatory blood pressure monitoring variability data using different devices.

  5. Some Effects of Horizontal-Tail Position on the Vertical-Tail Pressure Distributions of a Complete Model in Sideslip at High Subsonic Speeds

    NASA Technical Reports Server (NTRS)

    Alford, William J., Jr.

    1958-01-01

    An investigation has been made in the Langley high-speed 7- by 10-foot tunnel of some effects of horizontal-tail position on the vertical-tail pressure distributions of a complete model in sideslip at high subsonic speeds. The wing of the model was swept back 28.82 deg at the quarter-chord line and had an aspect ratio of 3.50, a taper ratio of 0.067, and NACA 65A004 airfoil sections parallel to the model plane of symmetry. Tests were made with the horizontal tail off, on the wing-chord plane extended, and in T-tail arrangements in forward and rearward locations. The test Mach numbers ranged from 0.60 to 0.92, which corresponds to a Reynolds number range from approximately 2.93 x 10(exp 6) to 3.69 x 10(exp 6), based on the wing mean aerodynamic chord. The sideslip angles varied from -3.9 deg to 12.7 deg at several selected angles of attack. The results indicated that, for a given angle of sideslip, increases in angle of attack caused reductions in the vertical-tail loads in the vicinity of the root chord and increases at the midspan and tip locations, with rearward movements in the local chordwise centers of pressure for the midspan locations and forward movements near the tip of the vertical tail. At the higher angles of attack all configurations investigated experienced outboard and rearward shifts in the center of pressure of the total vertical-tail load. Location of the horizontal tail on the wing- chord plane extended produced only small effects on the vertical-tail loads and centers of pressure. Locating the horizontal tail at the tip of the vertical tail in the forward position caused increases in the vertical-tail loads; this configuration, however, experienced considerable reduction in loads with increasing Mach number. Location of the horizontal tail at the tip of the vertical tail in the rearward position produced the largest increases in vertical-tail loads per degree sideslip angle; this configuration experienced the smallest variations of loads with

  6. Silicone ring versus pneumatic cuff tourniquet: a comparative quantitative study in healthy individuals.

    PubMed

    Drosos, Georgios I; Stavropoulos, Nikolaos I; Kazakos, Konstantinos; Tripsianis, Grigorios; Ververidis, Athanasios; Verettas, Dionisios-Alexandros

    2011-04-01

    The aim of the present study was to compare a new silicone ring tourniquet (SRT) with a classic pneumatic cuff tourniquet (PT) in terms of tolerance and recovery time following their use in healthy volunteers. Both tourniquets were applied in the arm and thigh of 15 healthy unmedicated volunteers. PT pressure was kept at 100 mmHg above the systolic blood pressure. The appropriate model of the SRT was used according to the systolic blood pressure. Pain was assessed by visual analogue scale and arterial blood pressure, pulse rate and oxygen saturation were monitored in all volunteers. There was no statistically significant difference in tolerance time between SRT and PT in the arm (19.13 vs. 18.25 min) and thigh (21.52 vs. 21.39 min) nor in recovery time between the two devices. The SRT performed similarly to the classic PT in terms of tolerance and recovery time when applied in the arm and thigh of unmedicated healthy volunteers.

  7. Reduction of Blood Pressure by AT1 Receptor Decoy Peptides.

    PubMed

    Re, Richard N; Chen, Ben; Alam, Jawed; Cook, Julia L

    2013-01-01

    We previously identified the binding of the chaperone protein gamma-aminobutyric acid receptor-associated protein (GABARAP) to a sequence on the carboxy-terminus of the angiotensin II AT1 receptor (AT1R) and showed that this binding enhances AT1R trafficking to the cell surface as well as angiotensin signaling. In this study, we treated sodium-depleted mice with decoy peptides consisting either of a fusion of the cell-penetrating peptide penetratin and the GABARAP/AT1R binding sequence or penetratin fused to a mutated AT1R sequence. We used telemetry to measure blood pressure. Systolic and diastolic pressure fell during the 24 hours following decoy peptide injection but not after control peptide injection. Active cell-penetrating decoy peptide decreased 24-hour average systolic blood pressure from 129.8 ± 4.7 mmHg to 125.0 ± 6.0 mmHg (mean ± standard deviation). Diastolic blood pressure fell from 99.0 ± 7.1 mmHg to 95.0 ± 9.2 mmHg (n=5). Administration of the control peptide raised systolic blood pressure from 128.7 ± 1.3 mmHg to 131.7 ± 2.9 mmHg and diastolic pressure from 93.9 ± 4.5 mmHg to 95.9 ± 4.2 mmHg (n=5). The decreases in both systolic and diastolic blood pressure after active peptide administration were statistically significant compared to control peptide administration (P<0.05, two-tailed Wilcoxon rank-sum test). These results indicate the physiological and potentially therapeutic relevance of inhibitors of GABARAP/AT1R binding.

  8. Effect of tilting on blood pressure and interstitial fluid pressures of bluefish and smooth dogfish.

    PubMed

    Ogilvy, C S; DuBois, A B

    1982-01-01

    Tolerance of the circulatory system of fish for gravitational stress has not been measured previously. We examined this in bluefish (Pomatomus saltatrix) and smooth dogfish (Mustelus canis) by placing them horizontally on a V-board in air while their gills were perfused with aerated seawater, then tilting them head up for 0.5 h, and finally returning them to horizontal. Meanwhile, we recorded the blood pressure, pulse pressure, and heart rate in the ventral aorta, and interstitial fluid pressure in the head and tail. All four bluefish tolerated a 30 degrees tilt or even a 60 degrees tilt with little change in blood pressure or interstitial pressure in the anterior and posterior regions. All recovered afterward. However, in the seven dogfish examined, the posterior interstitial fluid pressure increased from 2.8 +/- 1.0 cmH2O before tilting to 11.8 +/- 3.3 cmH2O toward the end of a 30 degrees tilt lasting 30 min. The blood pressure decreased as the pulse pressure approached zero, showing that circulatory insufficiency had developed due to insufficient venous return to the heart. Most of the dogfish died within a few hours after the experiment. These findings are in keeping with the conclusion that the vasculature of bluefish has more rigidity, less permeability, and perhaps more compensatory tone than that of smooth dogfish. We speculate that bluefish may have evolved their circulatory tolerance for gravity as a cross-adaptation to the stresses imposed on the circulation by forward acceleration and by regional differences of transcutaneous pressure occurring during fast carangiform swimming.

  9. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  10. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  11. The diagnosis of aortoiliac disease. A noninvasive femoral cuff technique.

    PubMed Central

    Barringer, M; Poole, G V; Shircliffe, A C; Meredith, J W; Hightower, F; Plonk, G W

    1983-01-01

    An inexpensive femoral "cuff" developed in this noninvasive vascular laboratory allows pulse volume recordings and systolic pressure measurements of the femoral arteries. Using the parameters 1) femoral/brachial systolic pressure ratio, 2) wave amplitude, and 3) status of the dicrotic notch for assessment of results, it was found that the cuff correctly identified 59 of 62 limbs with at least 50% aortoiliac stenosis, with only two false-positive results, for an accuracy of 97%. The high, wide thigh cuff identified 57 of the 62 limbs, but had 45 false-positive results (77% accuracy). Use of the femoral "cuff" has refined the ability to identify the anatomic location of significant arterial stenoses in the lower extremities. Images Fig. 1. Fig. 2. PMID:6824373

  12. Reliability of Pain Measurements Using Computerized Cuff Algometry: A DoloCuff Reliability and Agreement Study.

    PubMed

    Kvistgaard Olsen, Jack; Fener, Dilay Kesgin; Waehrens, Eva Elisabet; Wulf Christensen, Anton; Jespersen, Anders; Danneskiold-Samsøe, Bente; Bartels, Else Marie

    2017-07-01

    Computerized pneumatic cuff pressure algometry (CPA) using the DoloCuff is a new method for pain assessment. Intra- and inter-rater reliabilities have not yet been established. Our aim was to examine the inter- and intrarater reliabilities of DoloCuff measures in healthy subjects. Twenty healthy subjects (ages 20 to 29 years) were assessed three times at 24-hour intervals by two trained raters. Inter-rater reliability was established based on the first and second assessments, whereas intrarater reliability was based on the second and third assessments. Subjects were randomized 1:1 to first assessment at either rater 1 or rater 2. The variables of interest were pressure pain threshold (PT), pressure pain tolerance (PTol), and temporal summation index (TSI). Reliability was estimated by a two-way mixed intraclass correlation coefficient (ICC) absolute agreement analysis. Reliability was considered excellent if ICC > 0.75, fair to good if 0.4 < ICC < 0.75, and poor if ICC < 0.4. Bias and random errors between raters and assessments were evaluated using 95% confidence interval (CI) and Bland-Altman plots. Inter-rater reliability for PT, PTol, and TSI was 0.88 (95% CI: 0.69 to 0.95), 0.86 (95% CI: 0.65 to 0.95), and 0.81 (95% CI: 0.42 to 0.94), respectively. The intrarater reliability for PT, PTol, and TSI was 0.81 (95% CI: 0.53 to 0.92), 0.89 (95% CI: 0.74 to 0.96), and 0.75 (95% CI: 0.28 to 0.91), respectively. Inter-rater reliability was excellent for PT, PTol, and TSI. Similarly, the intrarater reliability for PT and PTol was excellent, while borderline excellent/good for TSI. Therefore, the DoloCuff can be used to obtain reliable measures of pressure pain parameters in healthy subjects. © 2016 World Institute of Pain.

  13. Mice from lines selectively bred for high voluntary wheel running exhibit lower blood pressure during withdrawal from wheel access.

    PubMed

    Kolb, Erik M; Kelly, Scott A; Garland, Theodore

    2013-03-15

    Exercise is known to be rewarding and have positive effects on mental and physical health. Excessive exercise, however, can be the result of an underlying behavioral/physiological addiction. Both humans who exercise regularly and rodent models of exercise addiction sometimes display behavioral withdrawal symptoms, including depression and anxiety, when exercise is denied. However, few studies have examined the physiological state that occurs during this withdrawal period. Alterations in blood pressure (BP) are common physiological indicators of withdrawal in a variety of addictions. In this study, we examined exercise withdrawal in four replicate lines of mice selectively bred for high voluntary wheel running (HR lines). Mice from the HR lines run almost 3-fold greater distances on wheels than those from non-selected control lines, and have altered brain activity as well as increased behavioral despair when wheel access is removed. We tested the hypothesis that male HR mice have an altered cardiovascular response (heart rate, systolic, diastolic, and mean arterial pressure [MAP]) during exercise withdrawal. Measurements using an occlusion tail-cuff system were taken during 8 days of baseline, 6 days of wheel access, and 2 days of withdrawal (wheel access blocked). During withdrawal, HR mice had significantly lower systolic BP, diastolic BP, and MAP than controls, potentially indicating a differential dependence on voluntary wheel running in HR mice. This is the first characterization of a cardiovascular withdrawal response in an animal model of high voluntary exercise. Copyright © 2013. Published by Elsevier Inc.

  14. High blood pressure medicines

    MedlinePlus

    Hypertension - medicines ... blood vessel diseases. You may need to take medicines to lower your blood pressure if lifestyle changes ... blood pressure to the target level. WHEN ARE MEDICINES FOR HIGH BLOOD PRESSURE USED Most of the ...

  15. Continuous and Noninvasive Recording of Cardiovascular Parameters with the Finapres Finger Cuff Enhances Undergraduate Student Understanding of Physiology

    ERIC Educational Resources Information Center

    Hodgson, Yvonne; Choate, Julia

    2012-01-01

    The Finapres finger cuff recording system provides continuous calculations of beat-to-beat variations in cardiac output (CO), total peripheral resistance, heart rate (HR), and blood pressure (BP). This system is unique in that it allows experimental subjects to immediately, continuously, and noninvasively visualize changes in CO at rest and during…

  16. Blood Pressure Medicines

    MedlinePlus

    ... reducing sodium in your diet, you may need medicines. Blood pressure medicines work in different ways to lower blood pressure. ... and widen blood vessels. Often, two or more medicines work better than one. NIH: National Heart, Lung, ...

  17. Spatial Characteristics of the Unsteady Differential Pressures on 16 percent F/A-18 Vertical Tails

    NASA Technical Reports Server (NTRS)

    Moses, Robert W.; Ashley, Holt

    1998-01-01

    Buffeting is an aeroelastic phenomenon which plagues high performance aircraft at high angles of attack. For the F/A-18 at high angles of attack, vortices emanating from wing/fuselage leading edge extensions burst, immersing the vertical tails in their turbulent wake. The resulting buffeting of the vertical tails is a concern from fatigue and inspection points of view. Previous flight and wind-tunnel investigations to determine the buffet loads on the tail did not provide a complete description of the spatial characteristics of the unsteady differential pressures. Consequently, the unsteady differential pressures were considered to be fully correlated in the analyses of buffet and buffeting. The use of fully correlated pressures in estimating the generalized aerodynamic forces for the analysis of buffeting yielded responses that exceeded those measured in flight and in the wind tunnel. To learn more about the spatial characteristics of the unsteady differential pressures, an available 16%, sting-mounted, F-18 wind-tunnel model was modified and tested in the Transonic Dynamics Tunnel (TDT) at the NASA Langley Research Center as part of the ACROBAT (Actively Controlled Response Of Buffet-Affected Tails) program. Surface pressures were measured at high angles of attack on flexible and rigid tails. Cross-correlation and cross-spectral analyses of the pressure time histories indicate that the unsteady differential pressures are not fully correlated. In fact, the unsteady differential pressure resemble a wave that travels along the tail. At constant angle of attack, the pressure correlation varies with flight speed.

  18. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events.

    PubMed

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke; Torp-Pedersen, Christian

    2017-11-21

    To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0.01% (-0.3%; 0.1%) for cardiovascular mortality and -0.1% (-1.1%; 0.5%) for cardiovascular events. The difference in AUC (95% confidence interval) was 0.65% (0.22-1.08%) for cardiovascular mortality and 1.33% (0.83-1.84%) for cardiovascular events. Comparing daytime and night-time blood pressure, the median difference in 10-year risks was 0.002% (-0.1%; 0.1%) for cardiovascular mortality and -0.01% (-0.5%; 0.2%) for cardiovascular events. The difference in AUC was 0.10% (-0.08 to 0.29%) for cardiovascular mortality and 0.15% (-0.06 to 0.35%) for cardiovascular events. Ten-year predictions obtained from ambulatory blood pressure are similar to predictions from office blood pressure. Night-time blood pressure does not improve 10-year predictions obtained from daytime measurements. For an otherwise healthy population sufficient prognostic accuracy of cardiovascular risks can be achieved with office blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  19. Assessment of central haemomodynamics from a brachial cuff in a community setting

    PubMed Central

    2012-01-01

    Background Large artery stiffening and wave reflections are independent predictors of adverse events. To date, their assessment has been limited to specialised techniques and settings. A new, more practical method allowing assessment of central blood pressure from waveforms recorded using a conventional automated oscillometric monitor has recently been validated in laboratory settings. However, the feasibility of this method in a community based setting has not been assessed. Methods One-off peripheral and central haemodynamic (systolic and diastolic blood pressure (BP) and pulse pressure) and wave reflection parameters (augmentation pressure (AP) and index, AIx) were obtained from 1,903 volunteers in an Austrian community setting using a transfer-function like method (ARCSolver algorithm) and from waveforms recorded with a regular oscillometric cuff. We assessed these parameters for known differences and associations according to gender and age deciles from <30 years to >80 years in the whole population and a subset with a systolic BP < 140 mmHg. Results We obtained 1,793 measures of peripheral and central BP, PP and augmentation parameters. Age and gender associations with central haemodynamic and augmentation parameters reflected those previously established from reference standard non-invasive techniques under specialised settings. Findings were the same for patients with a systolic BP below 140 mmHg (i.e. normotensive). Lower values for AIx in the current study are possibly due to differences in sampling rates, detection frequency and/or averaging procedures and to lower numbers of volunteers in younger age groups. Conclusion A novel transfer-function like algorithm, using brachial cuff-based waveform recordings, provides robust and feasible estimates of central systolic pressure and augmentation in community-based settings. PMID:22734820

  20. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    NASA Astrophysics Data System (ADS)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  1. Assessing neuromuscular block at the larynx: the effect of change in resting cuff pressure and a comparison with video imaging in anesthetized humans.

    PubMed

    Girling, K J; Bedforth, N M; Spendlove, J L; Mahajan, R P

    1999-02-01

    Neuromuscular block (NMB) at the larynx has been assessed by measuring the cuff pressure (CP) in an endotracheal tube (ETT) placed between the vocal cords. In this study, we evaluated the decrease in resting cuff pressure (RCP) after the administration of rocuronium and the effect of this decrease on the assessment of NMB, and we compared CP measurement with an alternative technique, video imaging (VI). In 20 patients, NMB was determined at the hand by mechanomyography and at the larynx initially by CP and subsequently by VI, recording images using a fiberoptic bronchoscope via a laryngeal mask. Train-of-four stimuli were applied at both sites. After baseline measurements, the ETT was replaced, and rocuronium was infused to achieve a steady-state 50% (n = 10) or 75% (n = 10) block at the hand. CP measurements were recorded before and after restoration of RCP to prerocuronium pressure, followed by further VI measurements. The mean RCP decreased from 21 +/- 4 to 12 +/- 5 mm Hg after rocuronium. At 50% block at the hand, the CP estimate of block at the larynx with reduced RCP was 62% +/- 18%, and that after restoring RCP was 29% +/- 13%; VI estimated 27% +/- 14% block. At 75% block at the hand, CP and VI estimated 52% +/- 11% and 46% +/- 9% block, respectively (RCP maintained). We conclude that RCP decreases after the administration of rocuronium, that restoring RCP significantly alters CP estimates of NMB, and that VI is in agreement with CP measurement if RCP is maintained at prerelaxant values. In this study, we show that a muscle relaxant-induced decrease in resting tension at the larynx may confound the assessment of neuromuscular block by cuff pressure measurement. The preliminary data suggest that video imaging may provide a suitable alternative to cuff pressure measurement to assess neuromuscular block at the larynx.

  2. Post-Weaning Protein Malnutrition Increases Blood Pressure and Induces Endothelial Dysfunctions in Rats

    PubMed Central

    Siman, Fabiana D. M.; Silveira, Edna A.; Meira, Eduardo F.; da Costa, Carlos P.; Vassallo, Dalton V.; Padilha, Alessandra S.

    2012-01-01

    Malnutrition during critical periods in early life may increase the subsequent risk of hypertension and metabolic diseases in adulthood, but the underlying mechanisms are still unclear. We aimed to evaluate the effects of post-weaning protein malnutrition on blood pressure and vascular reactivity in aortic rings (conductance artery) and isolated-perfused tail arteries (resistance artery) from control (fed with Labina®) and post-weaning protein malnutrition rats (offspring that received a diet with low protein content for three months). Systolic and diastolic blood pressure and heart rate increased in the post-weaning protein malnutrition rats. In the aortic rings, reactivity to phenylephrine (10−10–3.10−4 M) was similar in both groups. Endothelium removal or L-NAME (10−4 M) incubation increased the response to phenylephrine, but the L-NAME effect was greater in the aortic rings from the post-weaning protein malnutrition rats. The protein expression of the endothelial nitric oxide isoform increased in the aortic rings from the post-weaning protein malnutrition rats. Incubation with apocynin (0.3 mM) reduced the response to phenylephrine in both groups, but this effect was higher in the post-weaning protein malnutrition rats, suggesting an increase of superoxide anion release. In the tail artery of the post-weaning protein malnutrition rats, the vascular reactivity to phenylephrine (0.001–300 µg) and the relaxation to acetylcholine (10−10–10−3 M) were increased. Post-weaning protein malnutrition increases blood pressure and induces vascular dysfunction. Although the vascular reactivity in the aortic rings did not change, an increase in superoxide anion and nitric oxide was observed in the post-weaning protein malnutrition rats. However, in the resistance arteries, the increased vascular reactivity may be a potential mechanism underlying the increased blood pressure observed in this model. PMID:22529948

  3. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    PubMed

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  4. Maternal Blood Pressure During Pregnancy and Early Childhood Blood Pressures in the Offspring

    PubMed Central

    Lim, Wai-Yee; Lee, Yung-Seng; Yap, Fabian Kok-Peng; Aris, Izzudin Mohd; Ngee, Lek; Meaney, Michael; Gluckman, Peter D.; Godfrey, Keith M.; Kwek, Kenneth; Chong, Yap-Seng; Saw, Seang-Mei; Pan, An

    2015-01-01

    Abstract Although epidemiological studies suggest that offspring of women with preeclampsia are at increased risk to higher blood pressures and cardiovascular disease, little is known about the nature of blood pressures between the mother and her offspring. As blood pressures comprise of both pulsatile (systolic blood pressure [SBP] and pulse pressure [PP]) and stable (diastolic blood pressure [DBP]) components, and they differ between central and peripheral sites, we sought to examine maternal peripheral and central blood pressure components in relation to offspring early childhood blood pressures. A prospective birth cohort of 567 Chinese, Malay, and Indian mother–offspring with complete blood pressure information were studied. Maternal brachial artery SBP, DBP, and PP were measured at 26 to 28 weeks gestation; and central SBP and PP were estimated from radial artery waveforms. Offspring brachial artery SBP, DBP, and PP were measured at 3 years of age. Associations between continuous variables of maternal blood pressures (peripheral SBP, DBP, PP, central SBP, and PP) and offspring blood pressures (peripheral SBP, DBP, and PP) were examined using multiple linear regression with adjustment for maternal characteristics (age, education level, parity, smoking status, alcohol consumption and physical activity during pregnancy, and pre-pregnancy BMI) and offspring characteristics (sex, ethnicity, BMI, and height at 3 years of age). In the multivariate models, offspring peripheral SBP increased by 0.08 (95% confidence interval 0.00–0.17, P = 0.06) mmHg with every 1-mmHg increase in maternal central SBP, and offspring peripheral PP increased by 0.10 (0.01–0.18, P = 0.03) mmHg for every 1-mmHg increase in maternal central PP. The relations of maternal-offspring peripheral blood pressures (SBP, DBP, and PP) were positive but not statistically significant, and the corresponding values were 0.05 (−0.03 to 0.13; P = 0.21), 0.03 (−0.04 to 0.10; P = 0

  5. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    PubMed

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  6. Assessment of the effectiveness of a ventilator associated pneumonia prevention bundle that contains endotracheal tube with subglottic drainage and cuff pressure monitorization.

    PubMed

    Akdogan, Ozlem; Ersoy, Yasemin; Kuzucu, Ciğdem; Gedik, Ender; Togal, Turkan; Yetkin, Funda

    The effectiveness of prevention bundles on the occurrence and mortality of ventilator associated pneumonia (VAP) was evaluated in many studies. However, the effectiveness of endotracheal tube with subglottic secretion drainage (ETT-SD) and cuff pressure monitorization in VAP bundles have not been adequately assessed. In this study, we aimed to evaluate the effectiveness of VAP bundle containing ETT-SD and cuff pressure monitorization. This was a prospective, controlled study that was carried out between March 2011 and April 2012 including intubated patients. The study was conducted at the Anesthesiology Intensive Care Unit 1 and 2 (10 beds each) in a 898-bed university hospital. Occurrence of VAP and compliance with the parameters of the VAP prevention bundles were assessed daily. Patients intubated with the standard endotracheal tube were recruited as controls, mainly in the first six months of the study as ETT-SD and cuff pressure monometer had not yet been implemented. In the second term, patients intubated with ETT-SD were included as cases. Occurrence of VAP, mortality, and compliance with VAP prevention bundles were monitored. A total of 133 patients, 37 cases and 96 controls were recruited. VAP incidence declined from 40.82 to 22.16 per 1000 ventilator days among controls and cases, respectively (p<005). On average, VAP occurred 17.33±21.09 days in the case group and 10.43±7.83 days in the control group (p=0.04). However, mortality of cases and controls at the 14th and 30th days was not different. VAP prevention bundles including the utilization of ETT-SD, monitoring cuff pressure, and oral care with chlorhexidine were efficient in reducing the rate of VAP. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. [Continuous inflation of a leaking cuff of an intubation tube].

    PubMed

    Boussard, N; Helmer, J; Rose, E; Lascombes, P

    1988-01-01

    Perforation of the cuff of the endotracheal tube peroperatively is a very serious problem, especially when it occurs in a patient prone on an orthopaedic table. This is even more dramatic when the patient is not breathing spontaneously and he cannot be turned over to be reintubated. Given the unusual character of this situation, an apparatus has been designed to keep the cuff inflated permanently. It was a circuit consisting of a manual pressure valve, flexible tubing, a peripheral catheter and the cuff supply tube. The gas used was medical air at 3 bar pressure. This method proved perfectly safe and efficient, the operation having continued without reintubation.

  8. Low blood pressure

    MedlinePlus

    Hypotension; Blood pressure - low; Postprandial hypotension; Orthostatic hypotension; Neurally mediated hypotension; NMH ... Blood pressure varies from one person to another. A drop as little as 20 mmHg, can cause ...

  9. High Blood Pressure (Hypertension)

    MedlinePlus

    ... For Consumers Consumer Information by Audience For Women High Blood Pressure (Hypertension) Share Tweet Linkedin Pin it More sharing options ... En Español Who is at risk? How is high blood pressure treated? Understanding your blood pressure: What do the ...

  10. Clinical effects of thigh cuffs during a 7-day 6° head-down bed rest

    NASA Astrophysics Data System (ADS)

    Pavy-Le Traon, Anne; Maillet, Alain; Vasseur Clausen, Pascale; Custaud, Marc-Antoine; Alferova, Irina; Gharib, Claude; Fortrat, Jacques-Olivier

    2001-08-01

    Thigh cuffs are used by Russian cosmonauts to limit the fluid shift induced by space flight. A ground simulation using the head-down bed rest (HDBR) model was performed to assess the effects of thigh cuffs on clinical tolerance and orthostatic adaptation. 8 male healthy volunteers (32.4±1.9 years) participated twice in a 7-day HDBR — one time with thigh cuffs (worm daily from 9 am to 7 pm) (TC) and one time without (WTC). Orthostatic tolerance was assessed by a 10 minute stand test and by a LBNP test (5 min at -15, -30, -45 mmHg) before (BDC-1) and at the end of the HDBR period (R+1). Plasma volume was measured before and at the end of HDBR by the Evans blue dye dilution technique. Thigh cuffs limits headache due to fluid shift, as well as the loss in plasma volume (TC: -5.85±0.95%; WTC: -9.09±0.82%, p<0.05). The mean duration of the stand test (R+1) did not differ in the two group (TC 7.1±1.3 min; WTC 7.0±1.0 min). The increase in HR and decrease in diastolic blood pressure were slightly but significantly larger without thigh cuffs. Duration of the LBNP tests did not differ with thigh cuffs. Thigh cuffs limit the symptoms due to fluid shift and the loss in plasma volume. They partly reduced the increase in HR during orthostatic stress but had no effect on duration of orthostatic stress tests.

  11. Blood Pressure Checker

    NASA Technical Reports Server (NTRS)

    1979-01-01

    An estimated 30 million people in the United States have high blood pressure, or hypertension. But a great many of them are unaware of it because hypertension, in its initial stages, displays no symptoms. Thus, the simply-operated blood pressure checking devices now widely located in public places are useful health aids. The one pictured above, called -Medimax 30, is a direct spinoff from NASA technology developed to monitor astronauts in space. For manned space flights, NASA wanted a compact, highly-reliable, extremely accurate method of checking astronauts' blood pressure without the need for a physician's interpretive skill. NASA's Johnson Space Center and Technology, Inc., a contractor, developed an electronic sound processor that automatically analyzes blood flow sounds to get both systolic (contracting arteries) and diastolic (expanding arteries) blood pressure measurements. NASA granted a patent license for this technology to Advanced Life Sciences, Inc., New York City, manufacturers of Medimax 30.

  12. High Blood Pressure

    MedlinePlus

    ... also make blood pressure rise. Eating too much sodium Unhealthy eating patterns, particularly eating too much sodium, ... you an adult who is curious about how sodium affects your blood pressure? This study is testing ...

  13. Low Blood Pressure

    MedlinePlus

    ... to low blood pressure are an abnormally low heart rate ( bradycardia ), problems with heart valves , heart attack and ... occurred. Is low blood pressure related to low heart rate? Find out . This content was last reviewed October ...

  14. Real-time measurement of blood pressure with Nexfin in a patient with thalidomide-related phocomelia.

    PubMed

    Earle, Rosie; Vaghadia, Himat; Shanahan, Enda; Tang, Raymond; Sawka, Andrew

    2016-11-01

    We report the novel application of photoplethysmographic technology with the Nexfin HD monitor for real-time measurement of blood pressure (BP) in a patient with tetraamelia. The patient was a 58-year-old man with tetraamelia secondary to thalidomide exposure in utero, who presented for surgical excision of a maxillary schwannoma. Because difficulty of cuff use on rudimentary limbs and failure to gain invasive arterial access due to abnormalities of limb vasculature, this population is known to pose some unique challenges for BP measurement. Nexfin may offer an alternative noninvasive method to detect BP in patients with phocomelia during the perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    PubMed Central

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  16. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    PubMed

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  17. Difference in vascular patterns between transosseous-equivalent and transosseous rotator cuff repair.

    PubMed

    Urita, Atsushi; Funakoshi, Tadanao; Horie, Tatsunori; Nishida, Mutsumi; Iwasaki, Norimasa

    2017-01-01

    Vascularity is the important factor of biologic healing of the repaired tissue. The purpose of this study was to clarify sequential vascular patterns of repaired rotator cuff by suture techniques. We randomized 21 shoulders in 20 patients undergoing arthroscopic rotator cuff repair into 2 groups: transosseous-equivalent repair (TOE group, n = 10) and transosseous repair (TO group, n = 11). Blood flow in 4 regions inside the cuff (lateral articular, lateral bursal, medial articular, and medial bursal), in the knotless suture anchor in the TOE group, and in the bone tunnel in the TO group was measured using contrast-enhanced ultrasound at 1 month, 2 months, 3 months, and 6 months postoperatively. The sequential vascular pattern inside the repaired rotator cuff was different between groups. The blood flow in the lateral articular area at 1 month, 2 months, and 3 months (P = .002, .005, and .025) and that in the lateral bursal area at 2 months (P = .031) in the TO group were significantly greater than those in the TOE group postoperatively. Blood flow was significantly greater for the bone tunnels in the TO group than for the knotless suture anchor in the TOE group at 1 month and 2 months postoperatively (P = .041 and .009). This study clarified that the sequential vascular pattern inside the repaired rotator cuff depends on the suture technique used. Bone tunnels through the footprint may contribute to biologic healing by increasing blood flow in the repaired rotator cuff. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp.

    PubMed

    Younessi Heravi, M A; Khalilzadeh, M A; Joharinia, S

    2014-03-01

    One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective :In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference between each cardiac cycle and a relative pulse wave. Finger pulse and ECG signals in lead I were recorded by a monitoring device. The output of monitoring device wasinserted in a computer by serial network communication. A software interface (Microsoft Visual C#.NET ) was used to display and process the signals in the computer. Time difference between each cardiac cycle and pulse signal was calculated throughout R wave detection in ECG and peak of pulse signal by the software. The relation between time difference in two waves and BP was determined then the coefficients of equation were obtained in different physical situations. The results of estimating BP were compared with the results of sphygmomanometer method and the error rate was calculated. In this study, 25 subjects participated among them 15 were male and 10 were female. The results showed that BP was linearly related to time difference. Average of coefficient correlation was 0.9±0.03 for systolic and 0.82±0.04 for diastolic blood pressure. The highest error percentage was calculated 8% for male and 11% for female group. Significant difference was observed between the different physical situation and arm movement changes. The relationship between time difference and age was estimated in a linear relationship with a correlation coefficient of 0.76. By determining linear relation values with high accuracy, BP can be measured with insignificant error. Therefore it can be suggested as a new method to measure the blood pressure continuously.

  19. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    PubMed

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  20. Current Biomechanical Concepts for Rotator Cuff Repair

    PubMed Central

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  1. Spatial Characteristics of F/A-18 Vertical Tail Buffet Pressures Measured in Flight

    NASA Technical Reports Server (NTRS)

    Moses, Robert W.; Shah, Gautam H.

    1998-01-01

    Buffeting is an aeroelastic phenomenon which plagues high performance aircraft, especially those with twin vertical tails, at high angles of attack. Previous wind-tunnel and flight tests were conducted to characterize the buffet loads on the vertical tails by measuring surface pressures, bending moments, and accelerations. Following these tests, buffeting estimates were computed using the measured buffet pressures and compared to the measured responses. The estimates did not match the measured data because the assumed spatial correlation of the buffet pressures was not correct. A better understanding of the partial (spatial) correlation of the differential buffet pressures on the tail was necessary to improve the buffeting estimates. Several wind-tunnel investigations were conducted for this purpose. When combined and compared, the results of these tests show that the partial correlation depends on and scales with flight conditions. One of the remaining questions is whether the windtunnel data is consistent with flight data. Presented herein, cross-spectra and coherence functions calculated from pressures that were measured on the high alpha research vehicle (HARV) indicate that the partial correlation of the buffet pressures in flight agrees with the partial correlation observed in the wind tunnel.

  2. Interdependency of Cystathione γ-Lyase and Cystathione β-Synthase in Hydrogen Sulfide–Induced Blood Pressure Regulation in Rats

    PubMed Central

    Roy, Alexander; Khan, Abdul H.; Islam, Mohammed T.; Prieto, Minolfa C.; Majid, Dewan S.A.

    2012-01-01

    Background Hydrogen sulfide (H2S), an endogenous vasoactive agent, is produced by cystathionine γ-lyase (CGL) and cystathionine β-synthase (CBS) enzymes. This study was conducted to evaluate the relative contribution of these enzymes in regulating systemic arterial pressure. Methods Sprague–Dawley rats were chronically treated with CGL inhibitor, -propargylglycine (PAG, 37.5 mg/kg/day; intraperitoneally, i.p.) or CBS inhibitor, aminooxyacetic acid (AOA, 8.75 mg/kg/day; i.p.) or in combination for 4 weeks and the effects on arterial pressure (tail-cuff plethysmography) and renal excretory function (24 h urine collections using metabolic cages) were assessed once in a week. Changes in renal blood flow (RBF; Ultrasonic flowmetry) and glomerular filtration rate (GFR; Inulin clearance) were assessed in acute experiments in anesthetized rats at the end of treatment period. Results Compared to vehicle treated control group, only the rats with combination therapy showed a decrease in urinary sulfate excretion rate (248 ± 47 vs. 591 ± 70 nmol/24 h; marker for endogenous H2S level) which was associated with an increase in mean arterial pressure (MAP; 130 ± 2 vs. 99 ± 2 mm Hg). Urine flow and sodium excretion were also increased in combination group as consequent to the increase in MAP. GFR did not alter due to these treatments but RBF was lowered (4 ± 0.3 vs. 7 ± 0.4 ml/min/g) only in the combination group compared to the control group. Conclusion These findings indicate that a deficiency in one enzyme's activity could be compensated by the activity of the other to maintain the endogenous H2S level, the deficiency of which modulates systemic and renal vascular resistances leading to the development of hypertension. PMID:21866187

  3. Variation of the Korotkoff Stethoscope Sounds During Blood Pressure Measurement: Analysis Using a Convolutional Neural Network.

    PubMed

    Pan, Fan; He, Peiyu; Liu, Chengyu; Li, Taiyong; Murray, Alan; Zheng, Dingchang

    2017-11-01

    Korotkoff sounds are known to change their characteristics during blood pressure (BP) measurement, resulting in some uncertainties for systolic and diastolic pressure (SBP and DBP) determinations. The aim of this study was to assess the variation of Korotkoff sounds during BP measurement by examining all stethoscope sounds associated with each heartbeat from above systole to below diastole during linear cuff deflation. Three repeat BP measurements were taken from 140 healthy subjects (age 21 to 73 years; 62 female and 78 male) by a trained observer, giving 420 measurements. During the BP measurements, the cuff pressure and stethoscope signals were simultaneously recorded digitally to a computer for subsequent analysis. Heartbeats were identified from the oscillometric cuff pressure pulses. The presence of each beat was used to create a time window (1 s, 2000 samples) centered on the oscillometric pulse peak for extracting beat-by-beat stethoscope sounds. A time-frequency two-dimensional matrix was obtained for the stethoscope sounds associated with each beat, and all beats between the manually determined SBPs and DBPs were labeled as "Korotkoff." A convolutional neural network was then used to analyze consistency in sound patterns that were associated with Korotkoff sounds. A 10-fold cross-validation strategy was applied to the stethoscope sounds from all 140 subjects, with the data from ten groups of 14 subjects being analyzed separately, allowing consistency to be evaluated between groups. Next, within-subject variation of the Korotkoff sounds analyzed from the three repeats was quantified, separately for each stethoscope sound beat. There was consistency between folds with no significant differences between groups of 14 subjects (P = 0.09 to P = 0.62). Our results showed that 80.7% beats at SBP and 69.5% at DBP were analyzed as Korotkoff sounds, with significant differences between adjacent beats at systole (13.1%, P = 0.001) and diastole (17.4%, P < 0

  4. Low Blood Pressure (Hypotension)

    MedlinePlus

    ... Low blood pressure on standing up (orthostatic, or postural, hypotension). This is a sudden drop in blood ... progressive damage to the autonomic nervous system, which controls involuntary functions such as blood pressure, heart rate, ...

  5. [Association between higher blood pressure level in children and adult blood pressure: 17 years follow-up results].

    PubMed

    Mu, Jian-Jun; Liu, Zhi-Quan; Yang, Jun; Ren, Jie; Liu, Wei-Min; Xu, Xiang-Lin; Xiong, Su-E

    2008-03-01

    Essential hypertension may begin at childhood. The aim of this study is to identify the risk factors of hypertension and detect the evolvement tracking of blood pressure in childhood. In this study, we followed up blood pressure changes in 4623 school children (6 - 15 years-old) from 1987 to 2005 in Hanzhong rural area. A total of 152 children were grouped to higher blood pressure group [systolic blood pressure (P(SBP)) >or= 75(th) (P(75))] and 140 children grouped to normal blood pressure group [P(SBP) < 50(th) (P(50))] and their blood pressure were re-measure 18-years later. The total follow-up rate was 70.2%. Follow-up blood pressure was significantly higher in higher blood pressure group at baseline than that in normal blood pressure group at baseline (P < 0.05). The hypertension rate at follow up was significantly higher in higher blood pressure group at baseline than that in normal blood pressure group at baseline (28.0% vs. 4.1%, P < 0.01). The risk for hypertension was 6.88 greater in higher blood pressure group at baseline than that in normal blood pressure group at baseline. Higher blood pressure at childhood is a risk of developing hypertension at adulthood.

  6. Optic nerve head blood flow response to reduced ocular perfusion pressure by alteration of either the blood pressure or intraocular pressure.

    PubMed

    Wang, Lin; Cull, Grant A; Fortune, Brad

    2015-04-01

    To test the hypothesis that blood flow autoregulation in the optic nerve head has less reserve to maintain normal blood flow in the face of blood pressure-induced ocular perfusion pressure decrease than a similar magnitude intraocular pressure-induced ocular perfusion pressure decrease. Twelve normal non-human primates were anesthetized by continuous intravenous infusion of pentobarbital. Optic nerve blood flow was monitored by laser speckle flowgraphy. In the first group of animals (n = 6), the experimental eye intraocular pressure was maintained at 10 mmHg using a saline reservoir connected to the anterior chamber. The blood pressure was gradually reduced by a slow injection of pentobarbital. In the second group (n = 6), the intraocular pressure was slowly increased from 10 mmHg to 50 mmHg by raising the reservoir. In both experimental groups, optic nerve head blood flow was measured continuously. The blood pressure and intraocular pressure were simultaneously recorded in all experiments. The optic nerve head blood flow showed significant difference between the two groups (p = 0.021, repeat measures analysis of variance). It declined significantly more in the blood pressure group compared to the intraocular pressure group when the ocular perfusion pressure was reduced to 35 mmHg (p < 0.045) and below. There was also a significant interaction between blood flow changes and the ocular perfusion pressure treatment (p = 0.004, adjusted Greenhouse & Geisser univariate test), indicating the gradually enlarged blood flow difference between the two groups was due to the ocular perfusion pressure decrease. The results show that optic nerve head blood flow is more susceptible to an ocular perfusion pressure decrease induced by lowering the blood pressure compared with that induced by increasing the intraocular pressure. This blood flow autoregulation capacity vulnerability to low blood pressure may provide experimental evidence related to the

  7. Comparison of Direct and Indirect Methods of Measuring Arterial Blood Pressure in Healthy Male Rhesus Macaques (Macaca mulatta).

    PubMed

    France, Logan K; Vermillion, Meghan S; Garrett, Caroline M

    2018-01-01

    Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct and accurate method for measuring blood pressure; however, this approach is invasive and of limited use during brief sedated examinations. The objective of this study was to determine which method of indirect blood pressure monitoring was most accurate compared with measurement by direct arterial catheterization. In addition, we sought to determine the relative accuracy of each indirect method (compared with direct arterial measurement) at a given body location and to assess whether the accuracy of each indirect method was dependent on body location. We compared direct blood pressure measurements by means of catheterization of the saphenous artery with oscillometric and ultrasonic Doppler flow detection measurements at 3 body locations (forearm, distal leg, and tail base) in 16 anesthetized, male rhesus macaques. The results indicate that oscillometry at the forearm is the best indirect method and location for accurately and consistently measuring blood pressure in healthy male rhesus macaques.

  8. Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.

    PubMed

    Zhang, Qingxue; Zhou, Dian; Zeng, Xuan

    2017-02-06

    Long-term continuous systolic blood pressure (SBP) and heart rate (HR) monitors are of tremendous value to medical (cardiovascular, circulatory and cerebrovascular management), wellness (emotional and stress tracking) and fitness (performance monitoring) applications, but face several major impediments, such as poor wearability, lack of widely accepted robust SBP models and insufficient proofing of the generalization ability of calibrated models. This paper proposes a wearable cuff-less electrocardiography (ECG) and photoplethysmogram (PPG)-based SBP and HR monitoring system and many efforts are made focusing on above challenges. Firstly, both ECG/PPG sensors are integrated into a single-arm band to provide a super wearability. A highly convenient but challenging single-lead configuration is proposed for weak single-arm-ECG acquisition, instead of placing the electrodes on the chest, or two wrists. Secondly, to identify heartbeats and estimate HR from the motion artifacts-sensitive weak arm-ECG, a machine learning-enabled framework is applied. Then ECG-PPG heartbeat pairs are determined for pulse transit time (PTT) measurement. Thirdly, a PTT&HR-SBP model is applied for SBP estimation, which is also compared with many PTT-SBP models to demonstrate the necessity to introduce HR information in model establishment. Fourthly, the fitted SBP models are further evaluated on the unseen data to illustrate the generalization ability. A customized hardware prototype was established and a dataset collected from ten volunteers was acquired to evaluate the proof-of-concept system. The semi-customized prototype successfully acquired from the left upper arm the PPG signal, and the weak ECG signal, the amplitude of which is only around 10% of that of the chest-ECG. The HR estimation has a mean absolute error (MAE) and a root mean square error (RMSE) of only 0.21 and 1.20 beats per min, respectively. Through the comparative analysis, the PTT&HR-SBP models significantly outperform

  9. Relationship Between 24-Hour Ambulatory Central Systolic Blood Pressure and Left Ventricular Mass: A Prospective Multicenter Study.

    PubMed

    Weber, Thomas; Wassertheurer, Siegfried; Schmidt-Trucksäss, Arno; Rodilla, Enrique; Ablasser, Cornelia; Jankowski, Piotr; Lorenza Muiesan, Maria; Giannattasio, Cristina; Mang, Claudia; Wilkinson, Ian; Kellermair, Jörg; Hametner, Bernhard; Pascual, Jose Maria; Zweiker, Robert; Czarnecka, Danuta; Paini, Anna; Salvetti, Massimo; Maloberti, Alessandro; McEniery, Carmel

    2017-12-01

    We investigated the relationship between left ventricular mass and brachial office as well as brachial and central ambulatory systolic blood pressure in 7 European centers. Central systolic pressure was measured with a validated oscillometric device, using a transfer function, and mean/diastolic pressure calibration. M-mode images were obtained by echocardiography, and left ventricular mass was determined by one single reader blinded to blood pressure. We studied 289 participants (137 women) free from antihypertensive drugs (mean age: 50.8 years). Mean office blood pressure was 145/88 mm Hg and mean brachial and central ambulatory systolic pressures were 127 and 128 mm Hg, respectively. Mean left ventricular mass was 93.3 kg/m 2 , and 25.6% had left ventricular hypertrophy. The correlation coefficient between left ventricular mass and brachial office, brachial ambulatory, and central ambulatory systolic pressure was 0.29, 0.41, and 0.47, respectively ( P =0.003 for comparison between brachial office and central ambulatory systolic pressure and 0.32 for comparison between brachial and central ambulatory systolic pressure). The results were consistent for men and women, and young and old participants. The areas under the curve for prediction of left ventricular hypertrophy were 0.618, 0.635, and 0.666 for brachial office, brachial, and central ambulatory systolic pressure, respectively ( P =0.03 for comparison between brachial and central ambulatory systolic pressure). In younger participants, central ambulatory systolic pressure was superior to both other measurements. Central ambulatory systolic pressure, measured with an oscillometric cuff, shows a strong trend toward a closer association with left ventricular mass and hypertrophy than brachial office/ambulatory systolic pressure. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01278732. © 2017 American Heart Association, Inc.

  10. Introversion associated with large differences between screening blood pressure and home blood pressure measurement: The Ohasama study.

    PubMed

    Hozawa, Atsushi; Ohkubo, Takayoshi; Obara, Taku; Metoki, Hirohito; Kikuya, Masahiro; Asayama, Kei; Totsune, Kazuhito; Hashimoto, Junichiro; Hoshi, Haruhisa; Arai, Yumiko; Satoh, Hiroshi; Hosokawa, Toru; Imai, Yutaka

    2006-11-01

    To explore the effect of personality on screening blood pressures measured in clinical settings and home blood pressure measurements. From 1997 to 1999, 699 participants underwent screening and home blood pressure measurements and completed the Japanese version of the short-form Eysenck personality questionnaire. An increased screening blood pressure was defined as screening blood pressure > or = 140/90 mmHg and an increased home blood pressure was defined as home blood pressure > or = 135/85 mmHg. Participants with lower extroversion scores (i.e., introversion) showed a greater difference between screening and home systolic blood pressure. The association between introversion and differences was statistically significant, even after adjustment for other possible factors (younger age, female, wide screening pulse pressure, never smoked, and no antihypertensive medication). The adjusted means of SBP differences were 7.3 and 4.4 mmHg among the lowest and highest extroversion quartiles, respectively (P for trend = 0.02). Other personality scores (psychoticism or neuroticism) were not associated with screening and home blood pressure differences. The incorporation of an extroversion score in the basic model consisting of the above factors that affected the difference between screening and home blood pressure slightly improved the prediction of a high home blood pressure. The area under the receiver operating characteristic curve increased by 0.037 among participants with high screening blood pressure and 0.006 for those with normal screening blood pressure compared with the basic model. Physicians may need to be aware of 'introverted' patients who have high blood pressure in clinic settings, because they have the potential for 'white-coat' hypertension.

  11. High Blood Pressure and Women

    MedlinePlus

    ... fact sheet on high blood pressure . Watch interactive animations of how blood pressure works . See all the ... Matter • Find Tools & Resources HBP Resources Risk Calculator Animation Library Track Your Blood Pressure: Print (PDF) | Online ...

  12. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    PubMed

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  13. High Blood Pressure and Kidney Disease

    MedlinePlus

    ... Your Kidneys & How They Work High Blood Pressure & Kidney Disease What is high blood pressure? Blood pressure ... have their blood pressure checked. What are the kidneys and what do they do? The kidneys are ...

  14. Brachial blood flow under relative levels of blood flow restriction is decreased in a nonlinear fashion.

    PubMed

    Mouser, J Grant; Ade, Carl J; Black, Christopher D; Bemben, Debra A; Bemben, Michael G

    2018-05-01

    Blood flow restriction (BFR), the application of external pressure to occlude venous return and restrict arterial inflow, has been shown to increase muscular size and strength when combined with low-load resistance exercise. BFR in the research setting uses a wide range of pressures, applying a pressure based upon an individual's systolic pressure or a percentage of occlusion pressure; not a directly determined reduction in blood flow. The relationship between relative pressure and blood flow has not been established. To measure blood flow in the arm under relative levels of BFR. Forty-five people (18-40 years old) participated. Arterial occlusion pressure in the right arm was measured using a 5-cm pneumatic cuff. Blood flow in the brachial artery was measured at rest and at pressures between 10% and 90% of occlusion using ultrasound. Blood flow decreased in a nonlinear, stepped fashion. Blood flow decreased at 10% of occlusion and remained constant until decreasing again at 40%, where it remained until 90% of occlusion. The decrease in brachial blood flow is not proportional to the applied relative pressure. The prescription of blood flow restriction should take into account the stimulus provided at each relative level of blood flow. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  15. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    PubMed

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P < 0.01) and average real variability (P < 0.05) of systolic blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P < 0.001). A positive correlation of serum calcium and parathyroid hormone with 24-h-average real variability of systolic BP was observed in the entire primary hyperparathyroidism patients group (P = 0.04, P  = 0.02; respectively). Systolic blood pressure variability is increased in normotensive

  16. Computerized Cuff Pressure Algometry as Guidance for Circumferential Tissue Compression for Wearable Soft Robotic Applications: A Systematic Review.

    PubMed

    Kermavnar, Tjaša; Power, Valerie; de Eyto, Adam; O'Sullivan, Leonard W

    2018-02-01

    In this article, we review the literature on quantitative sensory testing of deep somatic pain by means of computerized cuff pressure algometry (CPA) in search of pressure-related safety guidelines for wearable soft exoskeleton and robotics design. Most pressure-related safety thresholds to date are based on interface pressures and skin perfusion, although clinical research suggests the deep somatic tissues to be the most sensitive to excessive loading. With CPA, pain is induced in deeper layers of soft tissue at the limbs. The results indicate that circumferential compression leads to discomfort at ∼16-34 kPa, becomes painful at ∼20-27 kPa, and can become unbearable even below 40 kPa.

  17. Implanted Blood-Pressure-Measuring Device

    NASA Technical Reports Server (NTRS)

    Fischell, Robert E.

    1988-01-01

    Arterial pressure compared with ambient bodily-fluid pressure. Implanted apparatus, capable of measuring blood pressure of patient, includes differential-pressure transducer connected to pressure sensor positioned in major artery. Electrical signal is function of differential pressure between blood-pressure sensor and reference-pressure sensor transmitted through skin of patient to recorder or indicator.

  18. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    PubMed

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p < 0.05). Thirty-one patients (88.6%) had isolated nighttime hypertension, and 53 patients (73.6%) were non-dippers. All systolic blood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p < 0.05). Nocturnal non-dipping was not associated with severity of obesity. Obesity was associated with severity of hypertension, higher diastolic blood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  19. Serotonin and Blood Pressure Regulation

    PubMed Central

    Morrison, Shaun F.; Davis, Robert Patrick; Barman, Susan M.

    2012-01-01

    5-Hydroxytryptamine (5-HT; serotonin) was discovered more than 60 years ago as a substance isolated from blood. The neural effects of 5-HT have been well investigated and understood, thanks in part to the pharmacological tools available to dissect the serotonergic system and the development of the frequently prescribed selective serotonin-reuptake inhibitors. By contrast, our understanding of the role of 5-HT in the control and modification of blood pressure pales in comparison. Here we focus on the role of 5-HT in systemic blood pressure control. This review provides an in-depth study of the function and pharmacology of 5-HT in those tissues that can modify blood pressure (blood, vasculature, heart, adrenal gland, kidney, brain), with a focus on the autonomic nervous system that includes mechanisms of action and pharmacology of 5-HT within each system. We compare the change in blood pressure produced in different species by short- and long-term administration of 5-HT or selective serotonin receptor agonists. To further our understanding of the mechanisms through which 5-HT modifies blood pressure, we also describe the blood pressure effects of commonly used drugs that modify the actions of 5-HT. The pharmacology and physiological actions of 5-HT in modifying blood pressure are important, given its involvement in circulatory shock, orthostatic hypotension, serotonin syndrome and hypertension. PMID:22407614

  20. Relation of blood volume and blood pressure in orthostatic intolerance

    NASA Technical Reports Server (NTRS)

    Jacob, G.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.

    1998-01-01

    A complex but crucial relationship exists between blood volume and blood pressure in human subjects; it has been recognized that in essential hypertension, renovascular hypertension, and pheochromocytoma, the relationship between plasma volume and diastolic blood pressure is an inverse one. This phenomenon has not been studied in individuals with low normal and reduced blood pressures. Orthostatic intolerance is a commonly encountered abnormality in blood pressure regulation often associated with tachycardia in the standing position. Most of these patients have varying degrees of reduced blood volume. We tested the hypothesis that the relationship previously found between plasma volume and diastolic blood pressure in pressor states would also hold in orthostatic intolerance. We studied 16 patients with a history of symptomatic orthostatic intolerance associated with an elevation in plasma norepinephrine in the upright posture and hypovolemia in 9 patients and normovolemia in 7 patients. Our studies demonstrate an inverse relationship between plasma volume and diastolic blood pressure in patients with orthostatic intolerance. This finding also holds for the change in diastolic blood pressure in response to upright posture. In this relationship, patients with orthostatic intolerance with high plasma norepinephrine resemble those with essential hypertension, renovascular hypertension, and pheochromocytoma. We conclude that in a variety of conditions at both ends of the blood pressure spectrum, the seemingly paradoxical association of hypovolemia and diastolic blood pressure is preserved.

  1. Carotid interventions and blood pressure.

    PubMed

    Hirschl, Mirko; Kundi, Michael

    2014-12-01

    Arterial baroreceptors are pressure sensors found in the carotid sinus near the bifurcation of the carotid artery and in the aortic arch. Carotid interventions, whether endovascular or surgical, affect this complicated control system and the post-interventional blood pressure behavior. Comparisons between the intervention techniques, however, are challenging due to the varying measurement methods, duration of observation, and patient populations. The question as to which interventional method is preferable, if undisturbed regulation of blood pressure is concerned, still remains unanswered. The fact that blood pressure events (i.e., hemodynamic instability, hypertension, unstable blood pressure) frequently occur both immediately after intervention and in the long term, mandates a particularly careful cardiopulmonary and blood pressure monitoring. Direct and indirect measurements of baroreceptor sensitivity can be helpful in identifying high-risk patients, although the association to hard clinical endpoints is rarely documented for methodological reasons.

  2. Pioglitazone enhances the blood pressure-lowering effect of losartan via synergistic attenuation of angiotensin II-induced vasoconstriction.

    PubMed

    Kong, Xiang; Ma, Ming-Zhe; Qin, Li; Zhang, Yan; Li, Xiao-Yong; Wang, Guo-Dong; Su, Qing; Zhang, Dao-You

    2014-09-01

    This study was designed to investigate the underlying mechanisms of synergistic antihypertensive effect produced by combination therapy of losartan and pioglitazone in metabolic syndrome (MS) rats. An MS model was induced by feeding rats a high-fat, high-sodium diet and 20% sucrose solution. Losartan (20 mg/kg/day), pioglitazone (10 mg/kg/day), and their combination were orally administered for eight consecutive weeks. Systolic blood pressure (SBP) and mean arterial pressure (MAP) were measured using the tail-cuff method and carotid arterial catheterization, respectively. The aortas were isolated and in vitro vascular reactivity studies were performed. The protein expression of angiotensin type 1 receptor (AT1), endothelial nitric oxide synthase (eNOS), phosphorylated eNOS and nicotinamide adenine dinucleotide phosphate (NADPH) oxidase subunit p47(phox), level of nitrotyrosine as well as activity of eNOS and NADPH oxidase in aortas of MS rats were detected. After eight weeks of treatment, the SBP and MAP in the losartan (115 ± 5 and 106 ± 6 mmHg), pioglitazone (130 ± 6 and 118 ± 6 mmHg), and combination therapy (105 ± 6 and 98 ± 5 mmHg) groups were lower than those in the model group (150 ± 8 and 136 ± 9 mmHg). Combination therapy of losartan and pioglitazone reduced BP more than either monotherapy, and showed additive effects on improving endothelial dysfunction and abolishing the increased vascular responsiveness to angiotensin II. These synergistic effects were associated with further reductions in protein expression of p47(phox) and AT1, NADPH oxidase activity, and nitrotyrosine level. Our data indicate that combined treatment exerts more beneficial effects on lowering BP and improving vascular lesions. © The Author(s) 2013.

  3. High blood pressure - children

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  4. Hypertension (High Blood Pressure)

    MedlinePlus

    ... pressure to live. Without it, blood can't flow through our bodies and carry oxygen to our vital organs. But when blood pressure gets too high — a condition called hypertension — it can lead to ...

  5. [Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong].

    PubMed

    Hung, Kevin KC; Lai, W Y; Cocks, Robert A; Rainer, Timothy H; Graham, Colin A

    2015-10-01

    Automated wrist cuff blood pressure (BP) devices are more compact and easier to use, particularly when access to the upper arm is restricted, for example in emergencies. We tested the Omron HEM-650 wrist device using the validation criteria of the British Hypertension Society (BHS) protocol in a major emergency department (ED) in Hong Kong. 85 patients had three measurements each by both the Omron HEM-650 wrist device and the mercury sphygmomanometer. The conventional automated BP with arm cuff was also measured using an oscillometric (Colin BP-88S NXT) device for comparison. The Omron HEM-650 achieved a grade B for both systolic and diastolic BP and demonstrated acceptable accuracy and reliability in Chinese patients in the emergency setting. The Omron HEM 650 wrist device can be recommended for use in adult emergency patients. Further research is warranted for its use in pregnant women and critically ill patients.

  6. Saline soaked pledgets prevent carbon dioxide laser-induced endotracheal tube cuff ignition.

    PubMed

    Sosis, M B

    1995-08-01

    To determine whether saline soaked pledgets would protect the cuffs of polyvinylchloride (PVC) endotracheal tubes from carbon dioxide (CO2) laser-induced combustion. 12 PVC endotracheal tubes were studied. The cuffed end of each was placed in a graduated cylinder and flushed with 5 L/min of oxygen for 5 minutes. The endotracheal tube's cuff was then inflated with air and the system pressure set to 20 cm H2O. Research laboratory of a university hospital. Six of the endotracheal tube cuffs were protected with 1 inch by 3 inch saline soaked pledgets and six were left unprotected. A CO2 laser set to 40 watts was then fired at the cuffs. All six unprotected cuffs were ignited in less than 1 second. No significant combustion occurred at the six pledget protected endotracheal tube cuffs after 1 minute of laser fire. Under the conditions of this experiment, saline soaked pledgets protected PVC endotracheal tube cuffs from the CO2 laser.

  7. Regenerative Medicine in Rotator Cuff Injuries

    PubMed Central

    Randelli, Pietro; Ragone, Vincenza; Menon, Alessandra; Cabitza, Paolo; Banfi, Giuseppe

    2014-01-01

    Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP) is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs). Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research. PMID:25184132

  8. Diet, blood pressure, and multicollinearity.

    PubMed

    Reed, D; McGee, D; Yano, K; Hankin, J

    1985-01-01

    Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.

  9. Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko

    2013-01-01

    Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.

  10. Apparatus and method for processing Korotkov sounds. [for blood pressure measurement

    NASA Technical Reports Server (NTRS)

    Golden, D. P., Jr.; Hoffler, G. W.; Wolthuis, R. A. (Inventor)

    1974-01-01

    A Korotkov sound processor, used in a noninvasive automatic blood measuring system where the brachial artery is occluded by an inflatable cuff, is disclosed. The Korotkoff sound associated with the systolic event is determined when the ratio of the absolute value of a voltage signal, representing Korotkov sounds in the range of 18 to 26 Hz to a maximum absolute peak value of the unfiltered signals, first equals or exceeds a value of 0.45. Korotkov sound associated with the diastolic event is determined when a ratio of the voltage signal of the Korotkov sounds in the range of 40 to 60 Hz to the absolute peak value of such signals within a single measurement cycle first falls below a value of 0.17. The processor signals the occurrence of the systolic and diastolic events and these signals can be used to control a recorder to record pressure values for these events.

  11. What Is High Blood Pressure Medicine?

    MedlinePlus

    ANSWERS by heart Lifestyle + Risk Reduction High Blood Pressure What Is High Blood Pressure Medicine? Your doctor has prescribed medicine to help lower your blood pressure. You also need to make the ...

  12. African Americans and High Blood Pressure

    MedlinePlus

    ANSWERS by heart Lifestyle + Risk Reduction High Blood Pressure What About African Americans and High Blood Pressure? African Americans in the U.S. have a higher prevalence of high blood pressure (HBP) ...

  13. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

    PubMed

    Shafique, M; Kyriacou, P A; Pal, S K

    2012-06-01

    Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p < 0.05) than the AC PPG signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).

  14. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    PubMed

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  15. Static magnetic field blood pressure buffering, baroreflex vs. vascular blood pressure control mechanism.

    PubMed

    Gmitrov, Juraj

    2010-02-01

    We compared the effect of static magnetic field (SMF) and verapamil, a potent vascular calcium channel blocking agent, on sudden elevation in blood pressure in conjunction with arterial baroreflex sensitivity (BRS) and microcirculation. Forty-four experiments were performed on conscious rabbits sedated using pentobarbital intravenous (i.v.) infusion (5 mg kg(-1) h(-1)). Mean femoral artery blood pressure (MAP), heart rate, BRS and ear lobe skin microcirculatory blood flow, estimated using microphotoelectric plethysmography (MPPG), were simultaneously measured after a 40 min exposure of the sinocarotid baroreceptors to 350 mT SMF, generated by Nd(2)-Fe(14)-B magnets, or 30 min of verapamil i.v. administration (20 microg kg(-1) min(-1)). BRS was assessed from heart rate and MAP responses to i.v. bolus of nitroprusside and phenylephrine. The decrease in phenylephrine-induced abrupt elevation in MAP (DeltaMAP(AE)) was significantly larger after verapamil than after SMF exposure. DeltaMAP(AE) inversely correlated with verapamil-induced significant increase in DeltaMPPG (r = 0.53, p < 0.000) and with SMF-induced significant increase in DeltaBRS (r = 0.47, p < 0.016). Our results suggest that verapamil-potentiated vascular blood pressure buffering mechanism was more effective than SMF-potentiated baroreflex-mediated blood pressure buffering mechanism, and a potential benefit of both approaches in cardiovascular conditions with abrupt high elevation in blood pressure.

  16. Comparison of effects of ProSeal LMA™ laryngeal mask airway cuff inflation with air, oxygen, air:oxygen mixture and oxygen:nitrous oxide mixture in adults: A randomised, double-blind study.

    PubMed

    Sharma, Mona; Sinha, Renu; Trikha, Anjan; Ramachandran, Rashmi; Chandralekha, C

    2016-08-01

    Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O2:N2O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult patients for various parameters. A total of 120 patients were randomly allocated to four groups, according to composition of gases used to inflate the PLMA cuff to achieve 40 cmH2 O cuff pressure, air (Group A), 50% O2 :air (Group OA), 50% O2:N2O (Group ON) and 100% O2 (Group O). Cuff pressure, cuff volume and ventilator parameters were monitored intraoperatively. Pharyngolaryngeal parameters were assessed at 1, 2 and 24 h postoperatively. Statistical analysis was performed using ANOVA, Fisher's exact test and step-wise logistic regression. Cuff pressure significantly increased at 10, 15 and 30 min in Group A, OA and O from initial pressure. Cuff pressure decreased at 5 min in Group ON (36.6 ± 3.5 cmH2 O) (P = 0.42). PLMA cuff volume increased in Group A, OA, O, but decreased in Group ON (6.16 ± 2.8 ml [P < 0.001], 4.7 ± 3.8 ml [P < 0.001], 1.4 ± 3.19 ml [P = 0.023] and - 1.7 ± 4.9 ml [P = 0.064], respectively), from basal levels. Ventilatory parameters were comparable in all four groups. There was no significant association between sore throat and cuff pressure, with odds ratio 1.002. Cuff inflation with 50% O2:N2O mixture provided more stable cuff pressure in comparison to air, O2 :air, 100% O2 during O2:N2O anaesthesia. Ventilatory parameters did not change with variation in PLMA cuff pressure. Post-operative sore throat had no correlation with cuff pressure.

  17. Rotator cuff problems

    MedlinePlus

    ... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...

  18. Central blood pressure and chronic kidney disease

    PubMed Central

    Ohno, Yoichi; Kanno, Yoshihiko; Takenaka, Tsuneo

    2016-01-01

    In this review, we focused on the relationship between central blood pressure and chronic kidney diseases (CKD). Wave reflection is a major mechanism that determines central blood pressure in patients with CKD. Recent medical technology advances have enabled non-invasive central blood pressure measurements. Clinical trials have demonstrated that compared with brachial blood pressure, central blood pressure is a stronger risk factor for cardiovascular (CV) and renal diseases. CKD is characterized by a diminished renal autoregulatory ability, an augmented direct transmission of systemic blood pressure to glomeruli, and an increase in proteinuria. Any elevation in central blood pressure accelerates CKD progression. In the kidney, interstitial inflammation induces oxidative stress to handle proteinuria. Oxidative stress facilitates atherogenesis, increases arterial stiffness and central blood pressure, and worsens the CV prognosis in patients with CKD. A vicious cycle exists between CKD and central blood pressure. To stop this cycle, vasodilator antihypertensive drugs and statins can reduce central blood pressure and oxidative stress. Even in early-stage CKD, mineral and bone disorders (MBD) may develop. MBD promotes oxidative stress, arteriosclerosis, and elevated central blood pressure in patients with CKD. Early intervention or prevention seems necessary to maintain vascular health in patients with CKD. PMID:26788468

  19. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    PubMed Central

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  20. Endotracheal tube and laryngeal mask airway cuff volume changes with altitude: a rule of thumb for aeromedical transport.

    PubMed

    Mann, Catherine; Parkinson, Neil; Bleetman, Anthony

    2007-03-01

    Helicopters and light (unpressurised) aircraft are used increasingly for the transport of ventilated patients. Most of these patients are ventilated through endotracheal tubes (ETTs), others through laryngeal mask airways (LMAs). The cuffs of both ETTs and LMAs inflate with increases in altitude as barometric pressure decreases (30 mbar/1000 feet). Tracheal mucosa perfusion becomes compromised at a pressure of approximately 30 cm H2O; critical perfusion pressure is 50 cm H2O. The change in dimensions of the inflated cuffs of a size 8 ETT and a size 5 LMA were measured with digital callipers at 1000 feet intervals in the unpressurised cabin of an Agusta 109 helicopter used by the Warwickshire and Northamptonshire Air Ambulance. A linear expansion in cuff dimensions as a function of altitude increase was identified. For ETTs, a formula for removal of air from the cuff with increasing altitude was calculated and is recommended for use in aeromedical transfers. This is 1/17x1.1 = 0.06 ml/1000 foot ascent/ml initial cuff inflation. The data for LMA cuff expansion failed to show significant correlation with altitude change. Further work is required to determine a similar rule of thumb for LMA cuff deflation.

  1. The Effect of Job Strain on Nighttime Blood Pressure Dipping among Men and Women with High Blood Pressure

    PubMed Central

    Fan, Lin-bo; Blumenthal, James A.; Hinderliter, Alan L.; Sherwood, Andrew

    2013-01-01

    Objectives Blunted nighttime blood pressure dipping is an established cardiovascular risk factor. This study examined the effect of job strain on nighttime blood pressure dipping among men and women with high blood pressure. Methods The sample consisted of 122 blue collar and white collar workers (men=72, women=50). Job psychological demands, job control and social support were measured by the Job Content Questionnaire. Job strain was assessed by the ratio of job demands/job control. Nighttime blood pressure dipping was evaluated from 24-hour ambulatory blood pressure monitoring performed on three workdays. Results Men with high job strain had a 5.4 mm Hg higher sleep systolic blood pressure (P=0.03) and 3.5 mm Hg higher sleep pulse pressure (P=0.02) compared to men with low job strain. Men with high job strain had a smaller fall in systolic blood pressure and pulse pressure from awake to sleep than those with low job strain (P<0.05). Hierarchical analyses showed that job strain was an independent determinant of systolic blood pressure dipping (P=0.03) among men after adjusting for ethnicity, body mass index, anxiety and depression symptoms, current smoking status, and alcohol consumption. Further exploratory analyses indicated that job control was the salient component of job strain associated with blood pressure dipping (p=.03). Conclusions High job strain is associated with a blunting of the normal diurnal variation in blood pressure and pulse pressure, which may contribute to the relationship between job strain and cardiovascular disease. PMID:22460541

  2. Blood pressure monitor with a position sensor for wrist placement to eliminate hydrostatic pressure effect on blood pressure measurement.

    PubMed

    Sato, Hironori; Koshimizu, Hiroshi; Yamashita, Shingo; Ogura, Toshihiko

    2013-01-01

    Accurate measurement of blood pressure at wrist requires the heart and wrist to be kept at the same level to avoid the effects of hydrostatic pressure. Although a blood pressure monitor with a position sensor that guides appropriate forearm angle without use of a chair and desk has already been proposed, a similar functioning device for measuring upper arm blood pressure with a chair and desk is needed. In this study, a calculation model was first used to explore design of such a system. The findings were then implemented into design of a new blood pressure monitor. Results of various methods were compared. The calculation model of the wrist level from arthrosis angles and interarticulars lengths was developed and considered using published anthropometric dimensions. It is compared with 33 volunteer persons' experimental results. The calculated difference of level was -4.1 to 7.9 (cm) with a fixed chair and desk. The experimental result was -3.0 to 5.5 (cm) at left wrist and -2.1 to 6.3(cm) at right wrist. The absolute difference level equals ±4.8 (mmHg) of blood pressure readings according to the calculated result. This meets the AAMI requirements for a blood pressure monitor. In the conclusion, the calculation model is able to effectively evaluate the difference between the heart and wrist level. Improving the method for maintaining wrist to heart level will improve wrist blood pressure measurement accuracy when also sitting in the chair at a desk. The leading angle of user's forearm using a position sensor is shown to work for this purpose.

  3. MUSCLE METABOLISM WITH BLOOD FLOW RESTRICTION IN CHRONIC FATIGUE SYNDROME

    PubMed Central

    McCully, Kevin K.; Smith, Sinclair; Rajaei, Sheeva; Leigh, John S.; Natelson, Benjamin H.

    2009-01-01

    The purpose of this study was to determine if chronic fatigue syndrome (CFS) is associated with reduced blood flow and muscle oxidative metabolism. Patients with CFS according to CDC criteria (n=19) were compared to normal sedentary subjects (n = 11). Muscle blood flow was measured in the femoral artery with Doppler ultrasound after exercise. Muscle metabolism was measured in the medial gastrocnemius muscle using 31P magnetic resonance spectroscopy (MRS). Muscle oxygen saturation and blood volume were measured using near-infrared spectroscopy. CFS and controls were not different in hyperemic blood flow or phosphocreatine recovery rate. Cuff pressures of 50,60,70,80,and 90 mmHg were used to partially restrict blood flow during recovery. All pressures reduced blood flow and oxidative metabolism, with 90 mmHg reducing blood flow by 46% and oxidative metabolism by 30.7% in CFS patients. Hyperemic blood flow during partial cuff occlusion was significantly reduced in CFS patients (P < 0.01), and recovery of oxygen saturation was slower (P < 0.05). No differences were seen in the amount of reduction in metabolism with partially reduced blood flow. In conclusion, CFS patients showed evidence of reduced hyperemic flow and reduced oxygen delivery, but no evidence that this impaired muscle metabolism. Thus, CFS patients might have altered control of blood flow, but this is unlikely to influence muscle metabolism. Further, abnormalities in muscle metabolism do not appear to be responsible for the CFS symptoms. PMID:14578362

  4. Blood pressure measurement: sitting and standing?

    PubMed

    Richard Conti, C

    2008-09-01

    Prior to discussing some thoughts about positional changes in blood pressure, I'd like to comment on the measurement of blood pressure.It is rare for a medical student, a resident-in-training, a cardiovascular fellow-in-training, or even a practicing or academic cardiologist to take the patient's blood pressure. I would even go so far as to say that it is uncommon for a registered nurse to measure blood pressure. Copyright (c) 2008 Wiley Periodicals, Inc.

  5. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    PubMed

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (P<0.001) and 3.3/3.5 mm Hg (P<0.01). The reduction of resting blood pressure was more pronounced in the 30 hypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; P<0.001 for all). Systemic vascular resistance decreased by 7.1% (P<0.05), plasma norepinephrine by 29% (P<0.001), and plasma renin activity by 20% (P<0.05). Body weight decreased by 1.2 kg (P<0.001), waist circumference by 2.8 cm (P<0.001), percent body fat by 1.4% (P<0.001), and the homeostasis model assessment index of insulin resistance by 0.31 U (P<0.01); HDL cholesterol increased by 0.032 mmol/L(-1) (P<0.05). In conclusion, aerobic endurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  6. High Blood Pressure and Kidney Disease

    MedlinePlus

    ... Kidney disease is diagnosed with urine and blood tests . Health care providers measure blood pressure with a blood pressure ... the sample to a lab for analysis. A health care provider may order a blood test to estimate how much blood the kidneys filter ...

  7. Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses

    PubMed Central

    Zhu, Mingping; Chen, Aiqing

    2017-01-01

    This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak amplitude larger than a threshold (0.5 for SBP, 0.7 for DBP, and 1.0 for MAP). They were also determined from cuff pressures associated with the above thresholds on a fitted curve polynomial curve of the oscillometric pulse peaks. Finally, the standard deviation (SD) of three repeats and its coefficient of variability (CV) were compared between the two automatic techniques. For the normotensive group, polynomial curve fitting significantly reduced SD of repeats from 3.6 to 2.5 mmHg for SBP and from 3.7 to 2.1 mmHg for MAP and reduced CV from 3.0% to 2.2% for SBP and from 4.3% to 2.4% for MAP (all P < 0.01). For the hypertensive group, SD of repeats decreased from 6.5 to 5.5 mmHg for SBP and from 6.7 to 4.2 mmHg for MAP, and CV decreased from 4.2% to 3.6% for SBP and from 5.8% to 3.8% for MAP (all P < 0.05). In conclusion, polynomial curve fitting of oscillometric pulses had the ability to reduce automatic BP measurement variability. PMID:28785580

  8. Effects of Standing and Light-Intensity Activity on Ambulatory Blood Pressure.

    PubMed

    Zeigler, Zachary S; Mullane, Sarah L; Crespo, Noe C; Buman, Matthew P; Gaesser, Glenn A

    2016-02-01

    This study aimed to compare ambulatory blood pressure (ABP) response to accumulated standing (STAND), cycling (CYCLE), and walking (WALK) to a sitting-only (SIT) day in adults. Nine overweight or obese (body mass index, 28.7 ± 2.7 kg · m(-2)) adults (30 ± 15 yr) participated in this randomized crossover full-factorial study. Four conditions (WALK, STAND, CYCLE, and SIT) were randomly performed 1 wk apart. WALK, STAND, and CYCLE conditions consisted of progressively increasing activity time to accumulate 2.5 h during an 8-h simulated workday. WALK (1.0 mph) and STAND (0.0 mph) were completed on a treadmill placed underneath a standing-height desk. During CYCLE, participants pedaled on a Monark cycle ergometer at a cadence and energy expenditure equivalent to WALK. Participants remained seated during the SIT condition. Participants wore an ABP cuff from 0800 h until 2200 h on all conditions. Linear mixed models were used to test condition differences in systolic (SBP) and diastolic (DBP) blood pressure. Chi-square was used to detect frequency difference of BP load. There was a whole-day (during and after work hours) SBP and DBP treatment effect (P < 0.01). Systolic blood pressure during STAND (132 ± 17 mm Hg), WALK (133 ± 17 mm Hg), and CYCLE (130 ± 16 mm Hg) were lower compared with that during SIT (137 ± 17 mm Hg) (all P < 0.01). CYCLE was lower than STAND (P = 0.04) and WALK (P < 0.01). For DBP, only CYCLE (69 ± 12 mm Hg) was lower than SIT (71 ± 13 mm Hg; P < 0.01). Compared with SIT, WALK, STAND, and CYCLE reduced SBP load by 4%, 4%, and 13%, respectively (all P < 0.01). Compared with sitting, accumulating 2.5 h of light-intensity physical activity or standing during an 8-h workday may reduce ABP during and after work hours.

  9. [Aging and blood pressure].

    PubMed

    Mendes, Romeu; Themudo Barata, J L

    2008-01-01

    High blood pressure is a major risk factor of cardiovascular diseases and has a high prevalence in the older individuals becoming in a risk factor associated with high cardiovascular mortality and morbidity among these population. This study has the objective to analyze the changes in the cardiovascular system inherent to the aging process, that provoke the increase of blood pressure levels with the advance of age and that can origin hypertension. With the aging process, changes in the anatomy and cardiovascular physiology occur, even in the absence of illness. High blood pressure is characterized as a systemic condition that involves the presence of structural changes of the arteries and the myocardium, associated to an endotelial and baroreceptors dysfunction.

  10. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  11. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  12. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  13. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  14. Continuous Blood Pressure Monitoring in Daily Life

    NASA Astrophysics Data System (ADS)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  15. An MRI-based leg model used to simulate biomechanical phenomena during cuff algometry: a finite element study.

    PubMed

    Manafi-Khanian, Bahram; Arendt-Nielsen, Lars; Graven-Nielsen, Thomas

    2016-03-01

    Cuff pressure stimulation is applicable for assessing deep-tissue pain sensitivity by exciting a variety of deep-tissue nociceptors. In this study, the relative transfer of biomechanical stresses and strains from the cuff via the skin to the muscle and the somatic tissue layers around bones were investigated. Cuff pressure was applied on the lower leg at three different stimulation intensities (mild pressure to pain). Three-dimensional finite element models including bones and three different layers of deep tissues were developed based on magnetic resonance images (MRI). The skin indentation maps at mild pressure, pain threshold, and intense painful stimulations were extracted from MRI and applied to the model. The mean stress under the cuff position around tibia was 4.6, 4.9 and around fibula 14.8, 16.4 times greater than mean stress of muscle surface in the same section at pain threshold and intense painful stimulations, respectively. At the same stimulation intensities, the mean strains around tibia were 36.4, 42.3 % and around fibula 32.9, 35.0 %, respectively, of mean strain on the muscle surface. Assuming strain as the ideal stimulus for nociceptors the results suggest that cuff algometry is less capable to challenge the nociceptors of tissues around bones as compared to more superficially located muscles.

  16. High Blood Pressure in Pregnancy

    MedlinePlus

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  17. High blood pressure - medicine-related

    MedlinePlus

    Drug-induced hypertension is high blood pressure caused by using a chemical substance or medicine. ... of the arteries There are several types of high blood pressure : Essential hypertension has no cause that can be ...

  18. Factors Associated with Blood Pressure Variability Based on Ambulatory Blood Pressure Monitoring in Subjects with Hypertension in China.

    PubMed

    Li, Wei; Yu, YanXia; Liang, Dehong; Jia, En-Zhi

    2017-01-01

    We examined the factors associated with blood pressure variability in a multi-ethnicity prospective study in China to gain more evidence to guide the prevention and management of hypertension through risk factor intervention. A total of 318 consecutive adult subjects aged 29-94 years with suspected or known hypertension were enrolled in this study. Blood pressure variability measurements were based on ambulatory blood pressure monitoring. To measure short-term reading-to-reading blood pressure variability in this study, we used the standard deviation(SD) of the blood pressure to estimate the blood pressure variability. The SDs of the blood pressure in this study ranged from 5.425 to 32.25, with a median of 10.81 (quartile range, 8.90-12.46). No significant difference regarding the level distribution of blood pressure variability was found across the various ethnicities. Spearman correlation analyses indicated that the SD of blood pressure was positively correlated with DSBP (r=0.302, p=<0.001), NSBP (r=0.383, p=<0.001), NDBP (r=0.230, p=<0.001), and FBG (r=0.129, p=0.023) and was negatively correlated with triglyceride (r=-0.289, p=<0.001), CR (r=-0.242, p=<0.001), HDL-C (r=-0.230, p=<0.001), LDL-C (r=-0.186, p=0.001), and apolipoprotein B levels (r=-0.157, p=0.006). Multiple linear regression analysis indicated that triglycerides (β=-0.217, p=<0.001), NSBP (β=0.174, p=0.003), FBG (β=0.128, p=0.024), DDBP (β=-0.128, p=0.022), and apolipoprotein A (β=-0.116, p=0.036) were significantly and independently associated with the blood pressure variability. In this study, blood pressure variability was significantly associated with not only blood pressure levels but also patient demographic, clinical and biochemical characteristics. © 2017 The Author(s). Published by S. Karger AG, Basel.

  19. Ambulatory blood pressure profiles in familial dysautonomia.

    PubMed

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  20. LB01.06: VISIT-TO-VISIT BLOOD PRESSURE VARIABILITY AND CARDIOVASCULAR OUTCOMES IN FELODIPINE EVENT REDUCTION STUDY.

    PubMed

    Zhang, Y; Zhang, X; Liu, L; Zanchetti, A

    2015-06-01

    Many antihypertensive outcome trials have shown that visit-to-visit blood pressure variability is correlated closely with clinical outcomes in hypertensive patients. The objective of the study was to investigate the relationship between visit-to-visit blood pressure variability (BPV) and the major cardiovascular outcomes in the Chinese hypertensive patients. Felodipine Event Reduction (FEVER) study was a double-blind, randomized trial on 9711 Chinese hypertensive patients, in whom cardiovascular outcomes were significantly reduced by more intense therapy achieving a mean of 138 mmHg SBP compared with less-intense therapy achieving a mean of 142 mmHg. Visit-to-visit BPV during the follow-up period [defined as standard deviation (SD), coefficient of variation (CV), and average real variability(ARV)] was derived from casual cuff BP measures after six months follow-up until the end of the study. Hazard ratios (HRs), for the incidence of CVD associated with SD, CV, and ARV of SBP and DBP were calculated using Cox proportional hazard models. Overall predictive power [area under receiver operating characteristic (AUC ROC) curve] of the level of blood pressure, blood pressure variability and other baseline characteristics was calculated. In FEVER study, visit-to-visit variability in SBP were significant predictors of subsequent stroke [eg, hazard ratios [HR] for ARV, SD and CV was 1.071 (95% CI: 1.025-1.118), 1.373 (95% CI: 1.159-1.626) and 0.572 (95% CI: 0.451-0,726)]. Visit-to-visit variability in DBP were also showed similar trend [eg, HR for ARV, SD and CV was 1.066 (95% CI: 0.992-1.145), 1.931 (95% CI: 1.435-2.598) and 0.558 (95% CI: 0.438-0,710)]. However, using the analysis of AUC ROC analysis, the risk importance sequence of the stroke events in this cohort was level of SBP, age, level of DBP ARV, SD, sex, CV and treatment. Visit-to-visit blood pressure variability has some effects on the cardiovascular outcomes in the Chinese hypertensive patents in the cohort in

  1. Blood pressure monitors for home

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  2. Blood pressure documentation in the emergency department

    PubMed Central

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  3. Artificial urinary sphincter revision for urethral atrophy: Comparing single cuff downsizing and tandem cuff placement.

    PubMed

    Linder, Brian J; Viers, Boyd R; Ziegelmann, Matthew J; Rivera, Marcelino E; Elliott, Daniel S

    2017-01-01

    To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy. Copyright® by the International Brazilian Journal of Urology.

  4. Fabrication and performance analysis of a DEA cuff designed for dry-suit applications

    NASA Astrophysics Data System (ADS)

    Ahmadi, S.; Camacho Mattos, A.; Barbazza, A.; Soleimani, M.; Boscariol, P.; Menon, C.

    2013-03-01

    A method for manufacturing a cylindrical dielectric elastomer actuator (DEA) is presented. The cylindrical DEA can be used in fabricating the cuff area of dry-suits where the garment is very tight and wearing the suit is difficult. When electrically actuated, the DEA expands radially and the suit can be worn more comfortably. In order to study the performance of the DEA, a customized testing setup was designed, and silicone-made cuff samples with different material stiffnesses were tested. Analytical and FEM modeling were considered to evaluate the experimental output. The results revealed that although the stiffness of the DEA material has a direct relationship with the radial constrictive pressure caused by mechanically stretching the DEA, it has a minor effect on the actuation pressure. It was also found that stacking multiple layers of the DEA to fabricate a laminated structure enabled the attainment of a desired variation of pressure required for the implementation of an electrically tunable cuff.

  5. Sodium-blood pressure interrelationship in pregnancy.

    PubMed

    Franx, A; Steegers, E A; de Boo, T; Thien, T; Merkus, J M

    1999-03-01

    In non-pregnant individuals, a strong positive association of sodium intake with blood pressure has been established, but the relationship between sodium intake and blood pressure in human pregnancy remains obscure up to date. The aim of this prospective observational cohort study was to assess the relationship between urinary sodium excretion (as a measure for intake) and blood pressure from the early second trimester onwards throughout pregnancy. The study group consisted of 667 low-risk women with singleton pregnancies, of whom 350 were nulliparous and 317 parous. Blood pressure was measured in a standardised fashion at predetermined intervals from the first antenatal visit prior to 16 weeks gestation until delivery. Urinary sodium excretion was measured in 24-h urine collections on at least four occasions between 16 and 38 weeks gestation. Main outcome measures were the coefficients of correlation between changes in urinary sodium output and changes in blood pressure during six different gestational epochs. No significant correlations were found between changes in urinary sodium output and changes in blood pressure. Correlation coefficients were alike for nulliparous and parous women and for different gestational intervals. Prior to 32 weeks gestation, no differences were observed in sodium excretion between women who remained normotensive and those who developed gestational hypertension. These results suggest that changes in sodium intake are not associated with blood pressure changes in low-risk pregnant women. Blood pressure increases as observed in the second half of normotensive and hypertensive pregnancies are unlikely to be caused by changes in renal sodium handling.

  6. Inter-arm blood pressure differences in pregnant women.

    PubMed

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  7. [Rotator cuff tear athropathy prevalence].

    PubMed

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  8. What Is High Blood Pressure?

    MedlinePlus

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  9. Controlling your high blood pressure

    MedlinePlus

    Controlling hypertension ... when you wake up. For people with very high blood pressure, this is when they are most at risk ... 2014 evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed ...

  10. Managing High Blood Pressure Medications

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Managing High Blood Pressure Medications Updated:Jan 10,2018 When your doctor ... checkup. This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  11. High blood pressure and eye disease

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/000999.htm High blood pressure and eye disease To use the sharing features on this page, please enable JavaScript. High blood pressure can damage blood vessels in the retina . The ...

  12. A Calibrated Method of Massage Therapy Decreases Systolic Blood Pressure Concomitant With Changes in Heart Rate Variability in Male Rats.

    PubMed

    Spurgin, Kurt A; Kaprelian, Anthony; Gutierrez, Roberto; Jha, Vidyasagar; Wilson, Christopher G; Dobyns, Abigail; Xu, Karen H; Curras-Collazo, Margarita C

    2017-02-01

    The purpose of this study was to develop a method for applying calibrated manual massage pressures by using commonly available, inexpensive sphygmomanometer parts and validate the use of this approach as a quantitative method of applying massage therapy to rodents. Massage pressures were monitored by using a modified neonatal blood pressure (BP) cuff attached to an aneroid gauge. Lightly anesthetized rats were stroked on the ventral abdomen for 5 minutes at pressures of 20 mm Hg and 40 mm Hg. Blood pressure was monitored noninvasively for 20 minutes following massage therapy at 5-minute intervals. Interexaminer reliability was assessed by applying 20 mm Hg and 40 mm Hg pressures to a digital scale in the presence or absence of the pressure gauge. With the use of this method, we observed good interexaminer reliability, with intraclass coefficients of 0.989 versus 0.624 in blinded controls. In Long-Evans rats, systolic BP dropped by an average of 9.86% ± 0.27% following application of 40 mm Hg massage pressure. Similar effects were seen following 20 mm Hg pressure (6.52% ± 1.7%), although latency to effect was greater than at 40 mm Hg. Sprague-Dawley rats behaved similarly to Long-Evans rats. Low-frequency/high-frequency ratio, a widely-used index of autonomic tone in cardiovascular regulation, showed a significant increase within 5 minutes after 40 mm Hg massage pressure was applied. The calibrated massage method was shown to be a reproducible method for applying massage pressures in rodents and lowering BP. Copyright © 2016. Published by Elsevier Inc.

  13. Path modelling of antecedent of diabetes mellitus on blood glucose measurements

    NASA Astrophysics Data System (ADS)

    Latif, Humaira'Abdul; Hamid, Mohd Rashid Ab; Azizan, Nor Azlinna; Jemain, Abdul Aziz

    2017-05-01

    Diabetes Mellitus (DM) is one of the non-communicable diseases and public health problems facing the worldwide population that includes Malaysia. Hitherto, the prevalence of DM becomes worsening with an estimated of 3.4 million Malaysians are diabetes sufferers and expectedly increasing year by year. Thus, this study is of great importance by regressing the medical factors that affect the blood glucose level using structural equation modelling (SEM). The SEM with partial least squares (PLS) estimation was applied to a secondary data of 644 respondents, aged ≥ 18 years in Malaysia. The data were collected in 2011 by Ministry of Health Malaysia (MOH). The variables under study are blood glucose level, cholesterol level (CL), systolic blood pressure (SBP), diastolic blood pressure (DBP), waist circumference (WC) and body mass index (BMI). From the modelling analysis, it showed that the cholesterol level (CL), systolic blood pressure (SBP) and waist circumference (WC) showed a positive significant relationship p < 0.01 (one-tailed) in influencing the blood sugar level. Whereas, diastolic blood pressure (DBP) is positively significant at p < 0.05 (one-tailed) and body mass index (BMI) is significant at p < 0.10 (one-tailed) towards blood glucose level. In conclusions, the findings from this study revealed the most salient predictors for blood glucose level which are CL, SBP and WC for diabetes mellitus among adults.

  14. Diabetes and blood pressure (image)

    MedlinePlus

    People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ... People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ...

  15. Anxiety: A Cause of High Blood Pressure?

    MedlinePlus

    ... cause of high blood pressure? Can anxiety cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Anxiety doesn't cause long-term high blood pressure (hypertension). But episodes of anxiety can cause dramatic, ...

  16. Contributions of social context to blood pressure: findings from a multilevel analysis of social capital and systolic blood pressure.

    PubMed

    Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori

    2011-06-01

    In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.

  17. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    PubMed Central

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  18. Biofeedback With Implanted Blood-Pressure Device

    NASA Technical Reports Server (NTRS)

    Rischell, Robert E.

    1988-01-01

    Additional uses found for equipment described in "Implanted Blood-Pressure-Measuring Device" (GSC-13042). Implanted with device electronic circuitry that measures, interprets, and transmits data via inductive link through patient's skin to external receiver. Receiver includes audible alarm generator activated when patient's blood pressure exceeds predetermined threshold. Also included in receiver a blood-pressure display, recorder, or both, for use by patient or physician.

  19. Intrathoracic Pressure Regulator for Blood Loss

    DTIC Science & Technology

    2016-05-24

    AFRL-SA-WP-SR-2016-0006 Intrathoracic Pressure Regulator for Blood Loss Richard D. Branson, RRT University of Cincinnati...Special Report 3. DATES COVERED (From – To) September 2011 – October 2013 4. TITLE AND SUBTITLE Intrathoracic Pressure Regulator for Blood Loss 5a...used to treat hypovolemia and cardiac arrest. Preclinical trials demonstrate that ITPR increases venous return and thereby restores blood pressure and

  20. Intrathoracic Pressure Regulator for Blood Loss

    DTIC Science & Technology

    2016-05-01

    AFRL-SA-WP-SR-2016-0006 Intrathoracic Pressure Regulator for Blood Loss Richard D. Branson, RRT University of Cincinnati...Special Report 3. DATES COVERED (From – To) September 2011 – October 2013 4. TITLE AND SUBTITLE Intrathoracic Pressure Regulator for Blood Loss 5a...used to treat hypovolemia and cardiac arrest. Preclinical trials demonstrate that ITPR increases venous return and thereby restores blood pressure and

  1. Beat-to-Beat Blood Pressure Monitor

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood

  2. Acquired tracheoesophageal fistula due to high intracuff pressure.

    PubMed

    Hameed, Akmal A; Mohamed, Hasan; Al-Mansoori, Motasem

    2008-01-01

    High-compliance endotracheal tube cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage and lead to tracheoesophageal fistula.Tracheostomy tube cuffs seal against the tracheal wall and prevent leakage of air around the tube, assuring that the tidal volume is delivered to the lungs. In the past, high-pressure cuffs were used, but these contributed to tracheal injury and have been replaced by high-volume, low-pressure cuffs. For long-term applications, some newer tubes have low-profile (tight to shaft) cuffs that facilitate the tracheostomy tube changes by eliminating the lip that forms when standard cuffs are deflated.

  3. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    PubMed

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; P<0.001 for both). The agreement between the methods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  4. Afterbody/nozzle pressure distributions of a twin-tail twin-engine fighter with axisymmetric nozzles at Mach numbers from 0.6 to 1.2

    NASA Technical Reports Server (NTRS)

    Wing, David J.

    1995-01-01

    Distributions of static pressure coefficient over the afterbody and axisymmetric nozzles of a generic, twin-tail twin-engine fighter were obtained in the Langley 16-Foot Transonic Tunnel. The longitudinal positions of the vertical and horizontal tails were varied for a total of six aft-end configurations. Static pressure coefficients were obtained at Mach numbers between 0.6 and 1.2, angles of attack between 0 deg and 8 deg, and nozzle pressure ratios ranging from jet-off to 8. The results of this investigation indicate that the influence of the vertical and horizontal tails extends beyond the vicinity of the tail-afterbody juncture. The pressure distribution affecting the aft-end drag is influenced more by the position of the vertical tails than by the position of the horizontal tails. Transonic tail-interference effects are seen at lower free-stream Mach numbers at positive angles of attack than at an angle of attack of 0 deg.

  5. Parecoxib Increases Blood Pressure Through Inhibition of Cyclooxygenase-2 Messenger RNA in an Experimental Model.

    PubMed

    Vértiz-Hernández, Ángel Antonio; Martínez-Morales, Flavio; Valle-Aguilera, Roberto; López-Sánchez, Pedro; Villalobos-Molina, Rafael; Pérez-Urizar, José

    2015-01-01

    Cyclooxygenase-2 selective inhibitors have been developed to alleviate pain and inflammation; however, the use of a selective cyclooxygenase-2 inhibitor is associated with mild edema, hypertension, and cardiovascular risk. To evaluate, in an experimental model in normotensive rats, the effect of treatment with parecoxib in comparison with diclofenac and aspirin and L-NAME, a non-selective nitric oxide synthetase, on mean arterial blood pressure, and cyclooxygenase-1 and -2 messenger RNA and protein expression in aortic tissue. Rats were treated for seven days with parecoxib (10 mg/kg/day), diclofenac (3.2 mg/kg/day), aspirin (10 mg/kg/day), or L-NAME (10 mg/kg/day). Mean arterial blood pressure was evaluated in rat tail; cyclooxygenase-1 and -2 were evaluated by reverse transcription-polymerase chain reaction and Western blot analysis in aortic tissue. Parecoxib and L-NAME, but not aspirin and diclofenac, increased mean arterial blood pressure by about 50% (p < 0.05) without changes in cardiac frequency. Messenger RNA cyclooxygenase-1 expression in aortic tissue was not modified with any drug (p < 0.05). L-NAME and parecoxib treatment decreased messenger RNA cyclooxygenase-2 and cyclooxygenase-2 (p < 0.05). While cyclooxygenase-1 protein decreased with the three drugs tested but not with L-NAME (p < 0.05), the cyclooxygenase-2 protein decreased only with aspirin and parecoxib (p < 0.05). Parecoxib increases the blood pressure of normotensive rats by the suppression of COX-2 gene expression, which apparently induced cardiovascular control.

  6. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    PubMed Central

    Lee, Sang-Suk; Nam, Dong-Hyun; Hong, You-Sik; Lee, Woo-Beom; Son, Il-Ho; Kim, Keun-Ho; Choi, Jong-Gu

    2011-01-01

    To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter. PMID:22319381

  7. Providing best practice in manual blood pressure measurement.

    PubMed

    Alexis, Obrey

    This article discusses the practical skills and underpinning knowledge needed when manually taking a patients blood pressure. The author defines blood pressure and the terms systolic and diastolic and explores the purpose of manual measurement. The article also goes on to examine what is meant by normal blood pressure, hypertension and hypotension, as well as factors that may influence blood pressure measurement. There is a brief outline of the equipment used for manually measuring blood pressure, followed by some factors that may affect the accuracy of the final reading. The author also highlights the different positions used for taking blood pressure and the arguments surrounding their respective merits. Finally, the article includes a practical step-by-step guide to manual blood pressure measurement.

  8. Significant interarm blood pressure difference predicts cardiovascular risk in hypertensive patients

    PubMed Central

    Kim, Su-A; Kim, Jang Young; Park, Jeong Bae

    2016-01-01

    Abstract There has been a rising interest in interarm blood pressure difference (IAD), due to its relationship with peripheral arterial disease and its possible relationship with cardiovascular disease. This study aimed to characterize hypertensive patients with a significant IAD in relation to cardiovascular risk. A total of 3699 patients (mean age, 61 ± 11 years) were prospectively enrolled in the study. Blood pressure (BP) was measured simultaneously in both arms 3 times using an automated cuff-oscillometric device. IAD was defined as the absolute difference in averaged BPs between the left and right arm, and an IAD ≥ 10 mm Hg was considered to be significant. The Framingham risk score was used to calculate the 10-year cardiovascular risk. The mean systolic IAD (sIAD) was 4.3 ± 4.1 mm Hg, and 285 (7.7%) patients showed significant sIAD. Patients with significant sIAD showed larger body mass index (P < 0.001), greater systolic BP (P = 0.050), more coronary artery disease (relative risk = 1.356, P = 0.034), and more cerebrovascular disease (relative risk = 1.521, P = 0.072). The mean 10-year cardiovascular risk was 9.3 ± 7.7%. By multiple regression, sIAD was significantly but weakly correlated with the 10-year cardiovascular risk (β = 0.135, P = 0.008). Patients with significant sIAD showed a higher prevalence of coronary artery disease, as well as an increase in 10-year cardiovascular risk. Therefore, accurate measurements of sIAD may serve as a simple and cost-effective tool for predicting cardiovascular risk in clinical settings. PMID:27310982

  9. Accessibility of Home Blood Pressure Monitors for Blind and Visually Impaired People

    PubMed Central

    Uslan, Mark M.; Burton, Darren M.; Wilson, Thomas E.; Taylor, Steven; Chertow, Bruce S.; Terry, Jack E.

    2007-01-01

    Background The prevalence of hypertension comorbid with diabetes is a significant health care issue. Use of the home blood pressure monitor (HBPM) for aiding in the control of hypertension is noteworthy because of benefits that accrue from following a home measurement regimen. To be usable by blind and visually impaired patients, HBPMs must have speech output to convey all screen information, an easily readable visual display, identifiable controls that are easy to use, and an accessible user manual. Methods Data on the physical aspects and the features and functions of nine Food and Drug Administration-approved HBPMs (eight of which were recommended by the British Hypertension Society) were tabulated and analyzed for usability by blind and visually impaired individuals. Video Electronics Standards Association standards were used to measure contrast modulation in the displays of the HBPMs. Ten persons who are blind or visually impaired and who have diabetes were surveyed to determine how they monitor their blood pressure and to learn their ideas for improvements in usability. Results Physical controls were found to be easy to identify, and operating procedures were found to be relatively simple on all of the HBPMs, but user manuals were either inaccessible or minimally accessible to blind persons. The two HBPMs that have speech output do not voice all of the information that is displayed on the screen. Some functions that are standard in the HBPMs without speech output, such as the feature for automatically setting cuff inflation volume and memory, were lacking in the HBPMs with speech output. These features were mentioned as desirable in interviews with legally blind persons who are diabetic and who monitor their blood pressure at home. Visual display output was large and adequate in all of the HBPMs. Michelson contrast for numeric digits in the HBPM displays was also measured, ranging from 55 to 75% for characters with dominant spatial frequency components lying

  10. Understanding Blood Pressure Readings

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  11. Increased systolic blood pressure in rat offspring following a maternal low-protein diet is normalized by maternal dietary choline supplementation.

    PubMed

    Bai, S Y; Briggs, D I; Vickers, M H

    2012-10-01

    An adverse prenatal environment may induce long-term metabolic consequences, in particular hypertension and cardiovascular disease. A maternal low-protein (LP) diet is well known to result in increased blood pressure (BP) in offspring. Choline has been shown to have direct BP-reducing effects in humans and animals. It has been suggested that endogenous choline synthesis via phosphatidylcholine is constrained during maternal LP exposure. The present study investigates the effect of choline supplementation to mothers fed a LP diet during pregnancy on systolic BP (SBP) in offspring as measured by tail-cuff plethysmography. Wistar rats were assigned to one of three diets to be fed ad libitum throughout pregnancy: (1) control diet (CONT, 20% protein); (2) an LP diet (9% protein); and (3) LP supplemented with choline (LP + C). Dams were fed the CONT diet throughout lactation and offspring were fed the CONT diet from weaning for the remainder of the trial. At postnatal day 150, SBP and retroperitoneal fat mass was significantly increased in LP offspring compared with CONT animals and was normalized in LP + C offspring. Effects of LP + C reduction in SBP were similar in both males and females. Plasma choline and phosphatidylcholine concentrations were not different across treatment groups, but maternal choline supplementation resulted in a significant reduction in homocysteine concentrations in LP + C offspring compared with LP and CONT animals. The present trial shows for the first time that maternal supplementation with dietary choline during periods of LP exposure can normalize increased SBP and fat mass observed in offspring in later life.

  12. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device. The...

  13. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device. The...

  14. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device. The...

  15. Lift and center of pressure of wing-body-tail combinations at subsonic, transonic, and supersonic speeds

    NASA Technical Reports Server (NTRS)

    Pitts, William C; Nielsen, Jack N; Kaattari, George E

    1957-01-01

    A method is presented for calculating the lift and centers of pressure of wing-body and wing-body-tail combinations at subsonic, transonic, and supersonic speeds. A set of design charts and a computing table are presented which reduce the computations to routine operations. Comparison between the estimated and experimental characteristics for a number of wing-body and wing-body-tail combinations shows correlation to within + or - 10 percent on lift and to within about + or - 0.02 of the body length on center of pressure.

  16. Increase of Short-Term Heart Rate Variability Induced by Blood Pressure Measurements during Ambulatory Blood Pressure Monitoring.

    PubMed

    Frigy, Attila; Magdás, Annamária; Moga, Victor-Dan; Coteț, Ioana Georgiana; Kozlovszky, Miklós; Szilágyi, László

    2017-01-01

    Objective. The possible effect of blood pressure measurements per se on heart rate variability (HRV) was studied in the setting of concomitant ambulatory blood pressure monitoring (ABPM) and Holter ECG monitoring (HM). Methods. In 25 hypertensive patients (14 women and 11 men, mean age: 58.1 years), 24-hour combined ABPM and HM were performed. For every blood pressure measurement, 2-minute ECG segments (before, during, and after measurement) were analyzed to obtain time domain parameters of HRV: SDNN and rMSSD. Mean of normal RR intervals (MNN), SDNN/MNN, and rMSSD/MNN were calculated, too. Parameter variations related to blood pressure measurements were analyzed using one-way ANOVA with multiple comparisons. Results. 2281 measurements (1518 during the day and 763 during the night) were included in the analysis. Both SDNN and SDNN/MNN had a constant (the same for 24-hour, daytime, and nighttime values) and significant change related to blood pressure measurements: an increase during measurements and a decrease after them ( p < 0.01 for any variation). Conclusion. In the setting of combined ABPM and HM, the blood pressure measurement itself produces an increase in short-term heart rate variability. Clarifying the physiological basis and the possible clinical value of this phenomenon needs further studies.

  17. Blood pressure normalization post-jugular venous balloon angioplasty.

    PubMed

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  18. Blood Pressure Regulation: Every Adaptation is an Integration?

    PubMed Central

    Joyner, Michael J.; Limberg, Jacqueline K.

    2013-01-01

    This focused review serves to explore relevant issues in regard to blood pressure regulation and by doing so, provides the initial stimulus paper for the Thematic Review series “Blood Pressure Regulation” to be published in the European Journal of Applied Physiology over the coming months. In this introduction, we highlight how variable normal blood pressure can be and challenge the reader to take another look at some key concepts related to blood pressure regulation. We point out that there is frequently an underappreciated balance between peripheral vasodilation and systemic blood pressure regulation and ask the question: Are changes in blood pressure, in effect, reasonable and integrated adaptations to the physiological challenge at hand? We conclude with the idea that blood pressure regulatory systems are both flexible and redundant; ensuring a wide variety of activities associated with life can be accompanied by a perfusion pressure that can serve multiple masters. PMID:23558925

  19. Effect of cocoa on blood pressure.

    PubMed

    Ried, Karin; Fakler, Peter; Stocks, Nigel P

    2017-04-25

    High blood pressure is an important risk factor for cardiovascular disease, contributing to about 50% of cardiovascular events worldwide and 37% of cardiovascular-related deaths in Western populations. Epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. Flavanols found in cocoa have been shown to increase the formation of endothelial nitric oxide which promotes vasodilation and therefore blood pressure reduction. Here we update previous meta-analyses on the effect of cocoa on blood pressure. To assess the effects on blood pressure of chocolate or cocoa products versus low-flavanol products or placebo in adults with or without hypertension when consumed for two weeks or longer. This is an updated version of the review initially published in 2012. In this updated version, we searched the following electronic databases from inception to November 2016: Cochrane Hypertension Group Specialised Register, CENTRAL, MEDLINE and Embase. We also searched international trial registries, and the reference lists of review articles and included trials. Randomised controlled trials (RCTs) investigating the effects of chocolate or cocoa products on systolic and diastolic blood pressure in adults for a minimum of two weeks duration. Two review authors independently extracted data and assessed the risks of bias in each trial. We conducted random-effects meta-analyses on the included studies using Review Manager 5. We explored heterogeneity with subgroup analyses by baseline blood pressure, flavanol content of control group, blinding, age and duration. Sensitivity analyses explored the influence of unusual study design. Thirty-five trials (including 40 treatment comparisons) met the inclusion criteria. Of these, we added 17 trials (20 treatment comparisons) to the 18 trials (20 treatment comparisons) in the previous version of this updated review.Trials provided participants with 30 to 1218 mg of flavanols (mean = 670 mg) in 1.4 to 105

  20. Cocoa, blood pressure, and cardiovascular health.

    PubMed

    Ferri, Claudio; Desideri, Giovambattista; Ferri, Livia; Proietti, Ilenia; Di Agostino, Stefania; Martella, Letizia; Mai, Francesca; Di Giosia, Paolo; Grassi, Davide

    2015-11-18

    High blood pressure is an important risk factor for cardiovascular disease and cardiovascular events worldwide. Clinical and epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. According to this, cocoa has a high content in polyphenols, especially flavanols. Flavanols have been described to exert favorable effects on endothelium-derived vasodilation via the stimulation of nitric oxide-synthase, the increased availability of l-arginine, and the decreased degradation of NO. Cocoa may also have a beneficial effect by protecting against oxidative stress alterations and via decreased platelet aggregation, decreased lipid oxidation, and insulin resistance. These effects are associated with a decrease of blood pressure and a favorable trend toward a reduction in cardiovascular events and strokes. Previous meta-analyses have shown that cocoa-rich foods may reduce blood pressure. Long-term trials investigating the effect of cocoa products are needed to determine whether or not blood pressure is reduced on a chronic basis by daily ingestion of cocoa. Furthermore, long-term trials investigating the effect of cocoa on clinical outcomes are also needed to assess whether cocoa has an effect on cardiovascular events. A 3 mmHg systolic blood pressure reduction has been estimated to decrease the risk of cardiovascular and all-cause mortality. This paper summarizes new findings concerning cocoa effects on blood pressure and cardiovascular health, focusing on putative mechanisms of action and "nutraceutical " viewpoints.

  1. Weightlifting: Bad for Your Blood Pressure?

    MedlinePlus

    ... blood pressure: A systematic review and meta-analysis. Journal of the American Heart Association. 2013;2:e004473. Getting active to control high blood pressure. American Heart Association. http://www.heart.org/HEARTORG/ ...

  2. Atmospheric pressure plasma accelerates tail regeneration in tadpoles Xenopus laevis

    NASA Astrophysics Data System (ADS)

    Rivie, A.; Martus, K.; Menon, J.

    2017-08-01

    Atmospheric pressure plasma is a partially ionized gas composed of neutral and charged particles, including electrons and ions, as well as reactive oxygen species (ROS). Recently, it is utilized as possible therapy in oncology, sterilization, skin diseases, wound healing and tissue regeneration. In this study we focused on effect of plasma exposure on tail regeneration of tadpoles, Xenopus leavis with special emphasis on role of ROS, antioxidant defenses and morphological features of the regenerate. When amputated region of the tail was exposed to the helium plasma it resulted in a faster rate of growth, elevated ROS and increase in antioxidant enzymes in the regenerate compared to that of untreated control. An increase in nitric oxide (free radical) as well as activity of nitric oxide synthase(s) were observed once the cells of the regeneration blastema - a mass of proliferating cells are ready for differentiation. Microscopically the cells of the regenerate of plasma treated tadpoles show altered morphology and characteristics of cellular hypoxia and oxidative stress. We summarize that plasma exposure accelerates the dynamics of wound healing and tail regeneration through its effects on cell proliferation and differentiation as well as angiogenesis mediated through ROS signaling.

  3. A study of weak anisotropy in electron pressure in the tail current sheet

    NASA Technical Reports Server (NTRS)

    Lee, D.-Y.; Voigt, G.-H.

    1995-01-01

    We adopt a magnetotail model with stretched field lines where ion motions are generally nonadiabatic and where it is assumed that the pressure anisotropy resides only in the electron pressure tensor. We show that the magnetic field lines with p(perpendicular) greater than p(parallel) are less stretched than the corresponding field lines in the isotropic model. For p(parallel) greater than p(perpendicular), the magnetic field lines become more and more stretched as the anisotropy approaches the marginal firehose limit, p(parallel) = p(perpendicular) + B(exp 2)/mu(sub 0). We also show that the tail current density is highly enhanced at the firehose limit, a situation that might be subject to a microscopic instability. However, we emphasize that the enhancement in the current density is notable only near the center of the tail current sheet (z = 0). Thus it remains unclear whether any microscopic instability can significantly alter the global magnetic field configuration of the tail. By comparing the radius of the field-line curvature at z = 0 with the particle's gyroradius, we suspect that even the conventional adiabatic description of electrons may become questionable very close to the marginal firehose limit.

  4. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    PubMed

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  5. Letter to editor: Blood pressure, hypertension and lead exposure.

    PubMed

    Yang, Wen-Yi; Staessen, Jan A

    2018-02-19

    A significant association of office diastolic blood pressure with low-level blood lead exposure was reported in a Brazilian adult population. However, caution should be taken to interpret these results. The multivariable-adjusted association with blood pressure was positive for diastolic blood pressure, but inverse for systolic blood pressure. The association sizes were infinitesimal without clinical relevance. The outcome measures, i.e. blood pressure and the prevalence of hypertension were analysed across categories of the blood lead distribution - not in relation to blood lead as continuous variable. Blood pressure was the average of two oscillometric office readings, whereas ambulatory monitoring is the state-of-the-art.

  6. Beat-to-Beat Blood Pressure Monitor

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  7. Blood Pressure, Perfusion Pressure, and Open-Angle Glaucoma: The Los Angeles Latino Eye Study

    PubMed Central

    Memarzadeh, Farnaz; Ying-Lai, Mei; Chung, Jessica; Azen, Stanley P.

    2010-01-01

    Purpose. To examine the cross-sectional relationship between blood pressure, perfusion pressure, and prevalence of open angle glaucoma (OAG) in an adult Latino population. Methods. Participants aged 40 years and older (N = 6130) from the Los Angeles Latino Eye Study (LALES), a large, population-based study of self-identified adult Latinos, underwent an interviewer-administered questionnaire and a complete ocular and clinical examination. Logistic regression was used to evaluate the covariate-adjusted association of OAG with systolic, diastolic, and mean blood pressures and perfusion pressures. Covariates included age, intraocular pressure, history of glaucoma treatment including medications and surgery, and history of blood pressure and treatment of blood pressure including use of medications. Results. Low systolic (odds ratio [OR] = 2.5), diastolic (OR = 1.9), and mean (OR = 3.6) perfusion pressures and low diastolic blood pressure (OR = 1.9) were associated with a higher prevalence of OAG in LALES participants. Higher systolic blood pressure and mean arterial blood pressure were associated with a higher prevalence of OAG. There was no relationship between the prevalence of OAG and the presence of a history of cardiovascular disease. Conclusions. Low diastolic, systolic and mean perfusion pressures, low diastolic blood pressure, and high systolic and mean arterial blood pressures are associated with a higher prevalence of OAG in adult Latinos. PMID:20089880

  8. Blood Pressure Quiz | NIH MedlinePlus the Magazine

    MedlinePlus

    ... this page please turn Javascript on. Feature: High Blood Pressure Blood Pressure Quiz Past Issues / Fall 2011 Table of Contents Blood pressure changes throughout the day. It… is highest while ...

  9. Muscle Microvascular Blood Flow, Oxygenation, pH, and Perfusion Pressure Decrease in Simulated Acute Compartment Syndrome.

    PubMed

    Challa, Sravya T; Hargens, Alan R; Uzosike, Amarachi; Macias, Brandon R

    2017-09-06

    The current gold standard for diagnosing acute compartment syndrome (ACS) is an assessment of clinical signs, invasive measurement of intramuscular pressure (IMP), and measurement of local perfusion pressure. However, IMP measurements have several shortcomings, including pain, risk of infection, risk of technique error, plugging of the catheter tip, lack of consensus on the diagnostic pressure threshold, and lack of specificity and sensitivity. The objective of this study was to evaluate muscle hemodynamics, oxygenation, and pH as diagnostic parameters in a human model of ACS. We hypothesized that as IMP increases, muscle microvascular blood flow, oxygenation, and pH decrease in the anterior compartment of a leg at heart level and that they decrease significantly more when the leg is elevated further. An external pneumatic leg pressure chamber, combined with a venous stasis thigh cuff, was used to increase IMP and simulate ACS. Eight healthy subjects (5 males and 3 females; mean age, 26 years) had photoplethysmography and near-infrared spectroscopy-pH sensors placed over the middle aspect of the tibialis anterior muscle of the right (experimental) and left (control) legs. Leg chamber pressure conditions (40, 50, and 60 mm Hg) were applied in a randomized order after baseline measurements were taken. Data were collected continuously for each 11-minute pressure condition, with an 11-minute recovery period after each condition, and the average of the last 6 minutes was used for data analyses. The same protocol was repeated with each subject's legs elevated 12 cm above heart level. Data were analyzed using repeated-measures analysis of variance (ANOVA). As IMP increased, muscle microvascular blood flow (p = 0.01), oxygenation (p < 0.001), and pH (p < 0.001) all decreased significantly in the experimental leg compared with the control leg. At all IMP levels, leg elevation significantly decreased muscle oxygenation (p = 0.013) and perfusion pressure (p = 0.03) compared

  10. Blood Pressure vs. Heart Rate

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 Understanding the difference ... your blood moving through your blood vessels, your heart rate is the number of times your heart beats ...

  11. Inflight Patient Monitoring/Blood Pressure Measurement Device

    DTIC Science & Technology

    1975-05-01

    PAGE 109 ADR DOSTUCGFlORK 1. PORT NUMUew p. GOVY ACCESSIN NO 0. PRECIPIENT’S CATALOG UMUNER SAM-TR-75-9 I6 % V 4. TITLE (&" &"lie) U. TYRE or REPORT...cuff midway between the rubber tubes for bulb and manometor 2.35 inches from the distal side of the cuff, and a trans- ducer mourit was designed and

  12. Biomechanical analysis of articular-sided partial-thickness rotator cuff tear and repair.

    PubMed

    Mihata, Teruhisa; McGarry, Michelle H; Ishihara, Yoko; Bui, Christopher N H; Alavekios, Damon; Neo, Masashi; Lee, Thay Q

    2015-02-01

    Articular-sided partial-thickness rotator cuff tears are common injuries in throwing athletes. The superior shoulder capsule beneath the supraspinatus and infraspinatus tendons works as a stabilizer of the glenohumeral joint. To assess the effect of articular-sided partial-thickness rotator cuff tear and repair on shoulder biomechanics. The hypothesis was that shoulder laxity might be changed because of superior capsular plication in transtendon repair of articular-sided partial-thickness rotator cuff tears. Controlled laboratory study. Nine fresh-frozen cadaveric shoulders were tested by using a custom shoulder-testing system at the simulated late-cocking phase and acceleration phase of throwing motion. Maximum glenohumeral external rotation angle, anterior translation, position of the humeral head apex with respect to the glenoid, internal impingement area, and glenohumeral and subacromial contact pressures were measured. Each specimen underwent 3 stages of testing: stage 1, with the intact shoulder; stage 2, after creation of articular-sided partial-thickness tears of the supraspinatus and infraspinatus tendons; and stage 3, after transtendon repair of the torn tendons by using 2 suture anchors. Articular-sided partial-thickness tears did not significantly change any of the shoulder biomechanical measurements. In the simulated late-cocking phase, transtendon rotator cuff repair resulted in decreased maximum external rotation angle by 4.2° (P = .03), posterior shift of the humeral head (1.1-mm shift; P = .02), decreased glenohumeral contact pressure by 1.7 MPa (56%; P = .004), and decreased internal impingement area by 26.4 mm(2) (65%; P < .001) compared with values in the torn shoulder. In the acceleration phase, the humeral head shifted inferiorly (1.2-mm shift; P = .03 vs torn shoulder), and glenohumeral anterior translation (1.5-mm decrease; P = .03 vs torn shoulder) and subacromial contact pressure (32% decrease; P = .004 vs intact shoulder) decreased

  13. Development of optoelectronic monitoring system for ear arterial pressure waveforms

    NASA Astrophysics Data System (ADS)

    Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando

    1994-02-01

    Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.

  14. Life style as a blood pressure determinant.

    PubMed

    Staessen, J A; Bieniaszewski, L; Pardaens, K; Petrov, V; Thijs, L; Fagard, R

    1996-09-01

    In Belgium, an affluent Western European country, participation in sports, alcohol intake, and living in a working class area were identified as the life style factors with the closest associations with the blood pressure level. Obesity was another important blood pressure correlate. Sodium intake, determined from the 24 h urinary output, and smoking were not associated with blood pressure. Controlled intervention studies have proven that weight reduction, endurance training and alcohol abstinence effectively reduce blood pressure. In the light of these intervention studies, the Belgian findings and the published work highlight the potential of preventive strategies aimed at these major life style factors.

  15. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    PubMed

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  16. Theoretical calculations of the pressure, forces, and moments at supersonic speeds due to various lateral motions acting on thin isolated vertical tails

    NASA Technical Reports Server (NTRS)

    Margolis, Kenneth; Bobbitt, Percy J

    1956-01-01

    Velocity potentials, pressure, distributions, and stability derivatives are derived by use of supersonic linearized theory for families of thin isolated vertical tails performing steady rolling, steady yawing, and constant-lateral-acceleration motions. Vertical-tail families (half-delta and rectangular plan forms) are considered for a broad Mach number range. Also considered are the vertical tail with arbitrary sweepback and taper ratio at Mach numbers for which both the leading edge and trailing edge of the tail are supersonic and the triangular vertical tail with a subsonic leading edge and a supersonic trailing edge. Expressions for potentials, pressures, and stability derivatives are tabulated.

  17. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    PubMed

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  18. The child-adolescent blood pressure study: I. Distribution of blood pressure levels in Seventh-Day-Adventist (SDA) and non-SDA children.

    PubMed

    Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E

    1981-12-01

    Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages.

  19. The child-adolescent blood pressure study: I. Distribution of blood pressure levels in Seventh-Day-Adventist (SDA) and non-SDA children.

    PubMed Central

    Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E

    1981-01-01

    Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages. PMID:7315999

  20. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

    PubMed

    Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin

    2015-08-01

    This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.

  1. Blood Pressure Matters: Keep Hypertension in Check

    MedlinePlus

    ... 2016 Print this issue Blood Pressure Matters Keep Hypertension in Check En español Send us your comments ... 1 in 3 adults in the U.S. has high blood pressure, but many don’t realize it. High blood ...

  2. 10 Ways to Control High Blood Pressure without Medication

    MedlinePlus

    10 ways to control high blood pressure without medication By making these 10 lifestyle changes, you can lower your blood pressure and reduce ... treating your high blood pressure. If you successfully control your blood pressure with a healthy lifestyle, you ...

  3. Blood pressure reprogramming adapter assists signal recording

    NASA Technical Reports Server (NTRS)

    Vick, H. A.

    1967-01-01

    Blood pressure reprogramming adapter separates the two components of a blood pressure signal, a dc pressure signal and an ac Korotkoff sounds signal, so that the Korotkoff sounds are recorded on one channel as received while the dc pressure signal is converted to FM and recorded on a second channel.

  4. EXPERIMENTAL ATHEROSCLEROSIS AND BLOOD PRESSURE IN THE RABBIT

    PubMed Central

    Dominguez, R.

    1927-01-01

    1. Van Leersum's range for the normal blood pressure in the rabbit, as recorded by his method, is confirmed. 2. Van Leersum's conclusion concerning the influence of a liver diet on the blood pressure of the rabbit is not substantiated by his data, since the fluctuations of blood pressure he obtained do not surpass his own recorded figures for normal animals. 3. Fluctuations of systolic blood pressure beyond the "normal" range are not necessary for the production of experimental atherosclerosis of the aorta in rabbits. Inversely, egg yolk feeding experiments in rabbits in which atherosclerosis of varying degree, even extreme, is obtained, are not accompanied by an elevation of blood pressure outside the "normal" range. 4. The fluctuations of blood pressure observed during experimental atherosclerosis do not simulate the condition of essential hypertension in man. PMID:19869349

  5. Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

    PubMed

    Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D

    2011-10-01

    To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.

  6. Automatic blood pressure measuring system (M092)

    NASA Technical Reports Server (NTRS)

    Nolte, R. W.

    1977-01-01

    The Blood Pressure Measuring System is described. It measures blood pressure by the noninvasive Korotkoff sound technique on a continual basis as physical stress is imposed during experiment M092, Lower Body Negative Pressure, and experiment M171, Metabolic Activity.

  7. Menopause and High Blood Pressure: What's the Connection?

    MedlinePlus

    ... pattern of blood pressure in postmenopausal women with hypertension in Nigeria. Ethiopian Journal of Health Sciences. 2014;24:153. April 28, 2016 Original article: http://www.mayoclinic.org/diseases-conditions/high-blood-pressure/expert-answers/menopause-and-high-blood-pressure/FAQ- ...

  8. Sleep Deprivation: A Cause of High Blood Pressure?

    MedlinePlus

    ... Is it true that sleep deprivation can cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Possibly. It's thought ... night may be at higher risk of developing high blood pressure or worsening already high blood pressure. There's also ...

  9. The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements.

    PubMed

    Babbs, Charles F

    2015-12-01

    This study explores the hypothesis that the sharper, high frequency Korotkoff sounds come from resonant motion of the arterial wall, which begins after the artery transitions from a buckled state to an expanding state. The motions of one mass, two nonlinear springs, and one damper, driven by transmural pressure under the cuff, are used to model and compute the Korotkoff sounds according to principles of classical Newtonian physics. The natural resonance of this spring-mass-damper system provides a concise, yet rigorous, explanation for the origin of Korotkoff sounds. Fundamentally, wall stretching in expansion requires more force than wall bending in buckling. At cuff pressures between systolic and diastolic arterial pressure, audible vibrations (> 40 Hz) occur during early expansion of the artery wall beyond its zero pressure radius after the outward moving mass of tissue experiences sudden deceleration, caused by the discontinuity in stiffness between bucked and expanded states. The idealized spring-mass-damper model faithfully reproduces the time-domain waveforms of actual Korotkoff sounds in humans. Appearance of arterial sounds occurs at or just above the level of systolic pressure. Disappearance of arterial sounds occurs at or just above the level of diastolic pressure. Muffling of the sounds is explained by increased resistance of the artery to collapse, caused by downstream venous engorgement. A simple analytical model can define the physical origin of Korotkoff sounds, suggesting improved mechanical or electronic filters for their selective detection and confirming the disappearance of the Korotkoff sounds as the optimal diastolic end point. Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  10. Anakinra reduces blood pressure and renal fibrosis in one kidney/DOCA/salt-induced hypertension.

    PubMed

    Ling, Yeong Hann; Krishnan, Shalini M; Chan, Christopher T; Diep, Henry; Ferens, Dorota; Chin-Dusting, Jaye; Kemp-Harper, Barbara K; Samuel, Chrishan S; Hewitson, Timothy D; Latz, Eicke; Mansell, Ashley; Sobey, Christopher G; Drummond, Grant R

    2017-02-01

    To determine whether a clinically-utilised IL-1 receptor antagonist, anakinra, reduces renal inflammation, structural damage and blood pressure (BP) in mice with established hypertension. Hypertension was induced in male mice by uninephrectomy, deoxycorticosterone acetate (2.4mg/d,s.c.) and replacement of drinking water with saline (1K/DOCA/salt). Control mice received uninephrectomy, a placebo pellet and normal drinking water. 10days post-surgery, mice commenced treatment with anakinra (75mg/kg/d, i.p.) or vehicle (0.9% saline, i.p.) for 11days. Systolic BP was measured by tail cuff while qPCR, immunohistochemistry and flow cytometry were used to measure inflammatory markers, collagen and immune cell infiltration in the kidneys. By 10days post-surgery, 1K/DOCA/salt-treated mice displayed elevated systolic BP (148.3±2.4mmHg) compared to control mice (121.7±2.7mmHg; n=18, P<0.0001). The intervention with anakinra reduced BP in 1K/DOCA/salt-treated mice by ∼20mmHg (n=16, P<0.05), but had no effect in controls. In 1K/DOCA/salt-treated mice, anakinra modestly reduced (∼30%) renal expression of some (CCL5, CCL2; n=7-8; P<0.05) but not all (ICAM-1, IL-6) inflammatory markers, and had no effect on immune cell infiltration (n=7-8, P>0.05). Anakinra reduced renal collagen content (n=6, P<0.01) but paradoxically appeared to exacerbate the renal and glomerular hypertrophy (n=8-9, P<0.001) that accompanied 1K/DOCA/salt-induced hypertension. Despite its anti-hypertensive and renal anti-fibrotic actions, anakinra had minimal effects on inflammation and leukocyte infiltration in mice with 1K/DOCA/salt-induced hypertension. Future studies will assess whether the anti-hypertensive actions of anakinra are mediated by protective actions in other BP-regulating or salt-handling organs such as the arteries, skin and brain. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Ambulatory or home measurement of blood pressure?

    PubMed

    Gosse, Philippe; Coulon, Paul

    2009-04-01

    Ambulatory blood pressure monitoring (ABPM) and home blood pressure (HBPM) monitoring have been shown to be superior to conventional measurement of blood pressure in terms of reproducibility, relationship to the impact of high blood pressure on target organs, and the prediction of cardiovascular events. Nevertheless, these 2 techniques have yet to find their place in the diagnosis of hypertension and during evaluation of the efficacy of antihypertensive treatment. Although these 2 methods do not give identical results in approximately 20% of cases, their diagnostic performance and prognostic value are quite comparable. Although ABPM remains a valuable tool in clinical research, its utilization in routine clinical practice is limited by cost and availability. HBPM is increasingly employed for informed and well-managed patients, and it can help to improve control of the patient's blood pressure. Physicians involved in the management of hypertensive patients should be aware of its value in order to assist patients in their care.

  12. Indirect Blood Pressure Measuring Device

    NASA Technical Reports Server (NTRS)

    Hum, L.; Cole, C. E.

    1973-01-01

    Design and performance of a blood pressure recording device for pediatric use are reported. A strain gage transducer with a copper-beryllium strip as force sensing element is used to monitor skin movements and to convert them into electrical signals proportional to those displacements. Experimental tests with this device in recording of force developed above the left femoral artery of a dog accurately produced a blood pressure curve.

  13. Factors affecting rotator cuff healing.

    PubMed

    Mall, Nathan A; Tanaka, Miho J; Choi, Luke S; Paletta, George A

    2014-05-07

    Several studies have noted that increasing age is a significant factor for diminished rotator cuff healing, while biomechanical studies have suggested the reason for this may be an inferior healing environment in older patients. Larger tears and fatty infiltration or atrophy negatively affect rotator cuff healing. Arthroscopic rotator cuff repair, double-row repairs, performing a concomitant acromioplasty, and the use of platelet-rich plasma (PRP) do not demonstrate an improvement in structural healing over mini-open rotator cuff repairs, single-row repairs, not performing an acromioplasty, or not using PRP. There is conflicting evidence to support postoperative rehabilitation protocols using early motion over immobilization following rotator cuff repair.

  14. Effect of selective vagal nerve stimulation on blood pressure, heart rate and respiratory rate in rats under metoprolol medication.

    PubMed

    Gierthmuehlen, Mortimer; Plachta, Dennis T T

    2016-02-01

    Selective vagal nerve stimulation (sVNS) has been shown to reduce blood pressure without major side effects in rats. This technology might be the key to non-medical antihypertensive treatment in patients with therapy-resistant hypertension. β-blockers are the first-line therapy of hypertension and have in general a bradycardic effect. As VNS itself can also promote bradycardia, it was the aim of this study to investigate the influence of the β1-selective blocker Metoprolol on the effect of sVNS especially with respect to the heart rate. In 10 male Wistar rats, a polyimide multichannel-cuff electrode was placed around the vagal nerve bundle to selectively stimulate the aortic depressor nerve fibers. The stimulation parameters were adapted to the thresholds of individual animals and were in the following ranges: frequency 30-50 Hz, amplitude 0.3-1.8 mA and pulse width 0.3-1.3 ms. Blood pressure responses were detected with a microtip transducer in the carotid artery, and electrocardiography was recorded with s.c. chest electrodes. After IV administration of Metoprolol (2 mg kg(-1) body weight), the animals' mean arterial blood pressure (MAP) and heart rate (HR) decreased significantly. Although the selective electrical stimulation of the baroreceptive fibers reduced MAP and HR, both effects were significantly alleviated by Metoprolol. As a side effect, the rate of stimulation-induced apnea significantly increased after Metoprolol administration. sVNS can lower the MAP under Metoprolol without causing severe bradycardia.

  15. A wireless blood pressure monitoring system for personal health management.

    PubMed

    Li, Wun-Jin; Luo, Yuan-Long; Chang, Yao-Shun; Lin, Yuan-Hsiang

    2010-01-01

    In this paper, we developed a wireless blood pressure monitoring system which provides a useful tool for users to measure and manage their daily blood pressure values. This system includes an ARM-based blood pressure monitor with a ZigBee wireless transmission module and a PC-based management unit with graphic user interface and database. The wireless blood pressure monitor can measure the blood pressure and heart rate and then store and forward the measuring information to the management unit through the ZigBee wireless transmission. On the management unit, user can easy to see their blood pressure variation in the past using a line chart. Accuracy of blood pressure measurement has been verified by a commercial blood pressure simulator and shown the bias of systolic blood pressure is ≤ 1 mmHg and the bias of diastolic blood pressure is ≤ 1.4 mmHg.

  16. Dietary fiber and blood pressure control.

    PubMed

    Aleixandre, A; Miguel, M

    2016-04-01

    In the past few years, new strategies to control blood pressure levels are emerging by developing new bioactive components of foods. Fiber has been linked to the prevention of a number of cardiovascular diseases and disorders. β-Glucan, the main soluble fiber component in oat grains, was initially linked to a reduction in plasma cholesterol. Several studies have shown afterward that dietary fiber may also improve glycaemia, insulin resistance and weight loss. The effect of dietary fiber on arterial blood pressure has been the subject of far fewer studies than its effect on the above-mentioned variables, but research has already shown that fiber intake can decrease arterial blood pressure in hypertensive rats. Moreover, certain fibers can improve arterial blood pressure when administered to hypertensive and pre-hypertensive subjects. The present review summarizes all those studies which attempt to establish the antihypertensive effects of dietary fiber, as well as its effect on other cardiovascular risk factors.

  17. [Breast feeding and systemic blood pressure in infants].

    PubMed

    Hernández-González, Martha A; Díaz-De-León, Luz V; Guízar-Mendoza, Juan M; Amador-Licona, Norma; Cipriano-González, Marisol; Díaz-Pérez, Raúl; Murillo-Ortiz, Blanca O; De-la-Roca-Chiapas, José María; Solorio-Meza, Sergio Eduardo

    2012-01-01

    Blood pressure levels in childhood influence these levels in adulthood, and breastfeeding has been considered such as a cardioprotective. We evaluated the association between blood pressure levels and feeding type in a group of infants. We conducted a comparative cross-sectional study in term infants with appropriate weight at birth, to compare blood pressure levels in those children with exclusively breastfeeding, mixed-feeding and formula feeding. The comparison of groups was performed using ANOVA and multiple regression analysis was used to identify variables associated with mean arterial blood pressure levels. A p value < 0.05 was considered significant. We included 20 men and 24 women per group. Infant Formula Feeding had higher current weight and weight gain compared with the other two groups (p < 0.05). Systolic, diastolic and mean blood pressure levels, as well as respiratory and heart rate were higher in the groups of exclusively formula feeding and mixed-feeding than in those with exclusively breastfeeding (p < 0.05). Multiple regression analysis identified that variables associated with mean blood pressure levels were current body mass index, weight gain and formula feeding. Infants in breastfeeding show lower blood pressure, BMI and weight gain.

  18. Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.

    PubMed

    Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M

    2010-10-01

    This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.

  19. Caffeine: How Does It Affect Blood Pressure?

    MedlinePlus

    ... coffee and other beverages varies by brand and method of preparation. Also, if you have high blood pressure, avoid caffeine right before activities that naturally increase your blood pressure, ...

  20. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  1. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  2. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  3. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  4. Delaminated rotator cuff tear: extension of delamination and cuff integrity after arthroscopic rotator cuff repair.

    PubMed

    Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John

    2015-05-01

    The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Preeclampsia and High Blood Pressure During Pregnancy

    MedlinePlus

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ034 PREGNANCY Preeclampsia and High Blood Pressure During Pregnancy • What is high blood pressure? • What is chronic hypertension? • What is gestational hypertension? • ...

  6. Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).

    PubMed

    Head, Valerie; Eshar, David; Nau, Melissa R

    2017-03-01

    Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.

  7. [Correlation between long time systolic blood pressure variability and short time systolic blood pressure in aged population].

    PubMed

    An, Shasha; Zheng, Xiaoming; Li, Zhifang; Wang, Yang; Wu, Yuntao; Zhang, Wenyan; Zhao, Haiyan; Wu, Aiping; Wang, Ruixia; Tao, Jie; Gao, Xinying; Wu, Shouling

    2015-11-01

    To investigate the correlation between long time systolic blood pressure variability(SBPV)and short time SBPV in aged population. A total of 752 subjects aged ≥60 years of Kailuan Group who took part in 2006-2007, 2008-2009, 2010-2011 and 2012-2013 health examination were included by cluster sampling method.Long time SBPV was calculated by standard deviation of mean systolic blood pressure measured in 2006-2007, 2008-2009, 2010-2011 and 2012-2013, standard deviation represents short time systolic blood pressure which is derived from 24 hour ambulatory blood pressure monitoring. The observation population was divided into three groups according to the third tertiles of the time systolic blood pressure variability: the first point(<9.09 mmHg (1 mmHg=0.133 kPa)), second point (≥9.09 mmHg, and <14.29 mmHg), and third point (≥14.29 mmHg). Multivariate logistic regression analysis was used to analyze the correlation between long time systolic blood pressure variability and short time systolic blood pressure. (1) The participants' age were (67.0±5.7) years old (284 women). (2) The 24 hours and daytime SSD were (14.7±4.0) mmHg, (14.7±3.5) mmHg, (15.7±4.4) mmHg (P=0.010) and (14.1±4.4) mmHg, (14.2±3.5) mmHg and (15.4±4.6) mmHg (P<0.001) according to the tertiles of long time systolic blood pressure variability, respectively, nighttime SSD were (12.0±4.4) mmHg, (11.8±4.8) mmHg and (11.9±4.9) mmHg (P=0.900). (3) Multiple logistic regression analysis showed that the tertiles of long time SSD was the risk factor for increasing daytime SSD>14.00 mmHg (OR=1.51, 95%CI: 1.03-2.23, P=0.037), but not a risk factor for increasing 24 hours SSD>14.41 mmHg (OR=1.10, 95%CI: 0.75-1.61, P=0.639) and nighttime SSD>11.11 mmHg (OR=0.98, 95%CI: 0.67-1.42, P=0.899). Increased long time SBPV is a risk factor for increasing daytime SBPV.

  8. Grandparental education, parental education and adolescent blood pressure.

    PubMed

    Kwok, Man Ki; Schooling, C Mary; Leung, Gabriel M; Subramanian, Subu V

    2016-09-01

    Maternal and paternal education could affect childhood blood pressure differently. Grandparental education might also play a role. Disentangling their contribution to childhood blood pressure may shed light on the persistence of disparities and potential windows of intervention. Using 5604 participants from a Chinese birth cohort born in 1997 and followed-up until ~13years (68% of follow-up), we examined the associations of parental education and grandparental education with age-, sex, and height-specific blood pressure z-scores or prehypertension status. Parental education was inversely associated with adolescent systolic (-0.11 z-score, equivalent to -1.17mmHg, 95% confidence interval (CI) -0.19 to -0.04 for grade ≥12 compared with grade ≤9) and diastolic blood pressure (-0.07 z-score, equivalent to -0.79mmHg, 95% CI -0.11 to -0.04). The magnitude of association was similar for maternal or paternal education. Grandparental education was not associated with adolescent blood pressure. No association with prehypertension was found. In an economically developed non-Western setting, both maternal and paternal, but not grandparental, education was associated with adolescent blood pressure. Blood pressure may be responsive to contemporary family socioeconomic conditions that may be scrutinized for suitable interventions. Copyright © 2016. Published by Elsevier Inc.

  9. Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study

    PubMed Central

    2013-01-01

    Background The primary objective of this study was to determine the efficiency of a pneumatic device in controlling cuff pressure (Pcuff) in patients intubated with polyurethane-cuffed tracheal tubes. Secondary objectives were to determine the impact of continuous control of Pcuff, and cuff shape on microaspiration of gastric contents. Methods Prospective randomized controlled study. All patients requiring intubation and mechanical ventilation ≥48 h were eligible. The first 32 patients were intubated with tapered polyurethane-cuffed, and the 32 following patients were intubated with cylindrical polyurethane-cuffed tracheal tubes. Patients randomly received 24 h of continuous control of Pcuff using a pneumatic device (Nosten®), and 24 h of routine care of Pcuff using a manometer. Target Pcuff was 25 cmH2O. Pcuff was continuously recorded, and pepsin was quantitatively measured in all tracheal aspirates during these periods. Results The pneumatic device was efficient in controlling Pcuff (med [IQ] 26 [24, 28] vs 22 [20, 28] cmH2O, during continuous control of Pcuff and routine care, respectively; p = 0.017). In addition, percentage of patients with underinflation (31% vs 68%) or overinflation (53% vs 100%) of tracheal cuff, and percentage of time spent with underinflation (0.9 [0, 17] vs 14% [4, 30]) or overinflation (0 [0, 2] vs 32% [9, 54]) were significantly (p < 0.001) reduced during continuous control of Pcuff compared with routine care. No significant difference was found in microaspiration of gastric content between continuous control of Pcuff compared with routine care, or between patients intubated with tapered compared with cylindrical polyurethane-cuffed tracheal tubes. Conclusion The pneumatic device was efficient in controlling Pcuff in critically ill patients intubated with polyurethane-cuffed tracheal tubes. Trial registration The Australian New Zealand Clinical Trials Registry (NCT01351259) PMID:24369057

  10. Blood pressure measurement: one arm or both arm?

    PubMed

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  11. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data.

    PubMed

    Karmali, Kunal N; Lloyd-Jones, Donald M; van der Leeuw, Joep; Goff, David C; Yusuf, Salim; Zanchetti, Alberto; Glasziou, Paul; Jackson, Rodney; Woodward, Mark; Rodgers, Anthony; Neal, Bruce C; Berge, Eivind; Teo, Koon; Davis, Barry R; Chalmers, John; Pepine, Carl; Rahimi, Kazem; Sundström, Johan

    2018-03-01

    Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD) prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP) level. We used individual participant data from the Blood Pressure Lowering Treatment Trialists' Collaboration (BPLTTC) from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants). During a median of 4.0 y of follow-up, 3,566 participants (7.5%) experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI) 0.70-0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53-0.55] for the SBP strategy). Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%-31%) fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%-18%) more events for the same number of persons treated. Compared with treating

  12. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT.

    PubMed

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman; Pandey, Ambarish; Olsen, Michael H; Bhatt, Deepak L

    2018-02-05

    The 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. In this exploratory analysis using baseline blood pressure assessments in Systolic Blood Pressure Intervention Trial (SPRINT), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (systolic blood pressure ≥130 mm Hg or diastolic blood pressure ≥80 mm Hg) compared with the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure (JNC 7) guidelines (systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg). The primary endpoint was the composite of myocardial infarction, other acute coronary syndromes, stroke, heart failure, or cardiovascular death. In 4683 patients assigned to the standard treatment arm of SPRINT, 2328 (49.7%) met hypertension thresholds by JNC 7 guidelines, and another 1424 (30.4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines compared with those newly identified with hypertension based on the new guidelines had similar risk of the primary endpoint (2.3 [95% confidence interval {CI}, 2.0-2.7] vs 2.0 [95% CI, 1.6-2.4] events per 100 patient-years; adjusted HR, 1.10 [95% CI, 0.84-1.44]; P = .48). The 2017 ACC/AHA high blood pressure guidelines are expected to significantly increase the prevalence of patients with hypertension (perhaps to a greater extent in higher-risk patient cohorts compared with the general population) and

  13. Blood pressure as a prognostic factor after acute stroke.

    PubMed

    Tikhonoff, Valérie; Zhang, Haifeng; Richart, Tom; Staessen, Jan A

    2009-10-01

    Stroke is the second most common cause of death worldwide and is the complication of hypertension that is most directly linked to blood pressure. Hypertension affects nearly 30% of the world's population; therefore, reducing blood pressure is key for the prevention of stroke. Unlike the established role of hypertension as a risk factor for stroke, the prognostic importance of blood pressure in determining outcome after acute stroke is unclear. The acute hypertensive response occurs in more than 50% of all patients with acute stroke and is associated with poor prognosis. The relation between the outcome of acute stroke and blood pressure is U-shaped, with the best outcome at systolic blood-pressure levels ranging from about 140 to 180 mm Hg. The evidence that decreasing blood pressure in hypertensive patients with acute ischaemic or haemorrhagic stroke improves prognosis needs further confirmation. Whether raising blood pressure to improve perfusion of ischaemic brain areas is beneficial remains even more uncertain. Present guidelines for the management of blood pressure in patients with acute stroke are not evidence-based, but results from ongoing trials might provide more informed recommendations for the future.

  14. Arterial blood pressure response to heavy resistance exercise.

    PubMed

    MacDougall, J D; Tuxen, D; Sale, D G; Moroz, J R; Sutton, J R

    1985-03-01

    The purpose of this study was to record the blood pressure response to heavy weight-lifting exercise in five experienced body builders. Blood pressure was directly recorded by means of a capacitance transducer connected to a catheter in the brachial artery. Intrathoracic pressure with the Valsalva maneuver was recorded as mouth pressure by having the subject maintain an open glottis while expiring against a column of Hg during the lifts. Exercises included single-arm curls, overhead presses, and both double- and single-leg presses performed to failure at 80, 90, 95, and 100% of maximum. Systolic and diastolic blood pressures rose rapidly to extremely high values during the concentric contraction phase for each lift and declined with the eccentric contraction. The greatest peak pressures occurred during the double-leg press where the mean value for the group was 320/250 mmHg, with pressures in one subject exceeding 480/350 mmHg. Peak pressures with the single-arm curl exercise reached a mean group value of 255/190 mmHg when repetitions were continued to failure. Mouth pressures of 30-50 Torr during a single maximum lift, or as subjects approached failure with a submaximal weight, indicate that a portion of the observed increase in blood pressure was caused by a Valsalva maneuver. It was concluded that when healthy young subjects perform weight-lifting exercises the mechanical compression of blood vessels combines with a potent pressor response and a Valsalva response to produce extreme elevations in blood pressure. Pressures are extreme even when exercise is performed with a relatively small muscle mass.

  15. [Central blood pressure and vascular damage].

    PubMed

    Pérez-Lahiguera, Francisco; Rodilla, Enrique; Costa, José Antonio; Pascual, José María

    2015-07-20

    The aim of this study was to assess the relationship between central blood pressure and vascular damage. This cross-sectional study involved 393 never treated hypertensive patients (166 women). Clinical blood pressure (BP), 24h blood pressure (BP24h) and central blood pressure (CBP) were measured. Vascular organ damage (VOD) was assessed by calculating the albumin/creatinine ratio (ACR), wave pulse pressure velocity and echocardiographic left ventricular mass index (LVMI). Patients with VOD had higher values of BP, BP24h, and CBP than patients without ACR. When comparing several systolic BP, systolic BP24h had a higher linear correlation with CBP (Z Steiger test: 2.26; P=.02) and LVMI (Z Steiger test: 3.23; P=.01) than PAC. In a multiple regression analysis corrected by age, sex and metabolic syndrome, all pressures were related with VOD but systolic BP24h showed the highest correlation. In a logistic regression analysis, having the highest tercile of systolic BP24h was the stronger predictor of VOD (multivariate odds ratio: 3.4; CI 95%: 2.5-5.5, P=.001). CBP does not have more correlation with VOD than other measurements of peripheral BP. Systolic BP24h is the BP measurement that best predicts VOD. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  16. Impact of baseline systolic blood pressure on visit-to-visit blood pressure variability: the Kailuan study.

    PubMed

    Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling

    2016-01-01

    To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.

  17. Association of betaine with blood pressure in dialysis patients.

    PubMed

    Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei

    2018-02-01

    Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.

  18. [Importance of ambulatory blood pressure monitoring in adolescent hypertension].

    PubMed

    Páll, Dénes; Juhász, Mária; Katona, Eva; Lengyel, Szabolcs; Komonyi, Eva; Fülesdi, Béla; Paragh, György

    2009-12-06

    The prevalence of adolescent hypertension is increasing. The national epidemiological study found 2.5% prevalence, while it is 4.5% according to the newest international survey. Repeated casual blood pressure measurements, but not ambulatory blood pressure monitoring is needed for the diagnosis of adolescent hypertension on the basis of the presently available European guideline. At the last decade growing evidence came into light for ambulatory blood pressure monitoring in adolescence. These data show better correlation with end-organ damages than casual measurements. In patients with hypertension diagnosed based on repeated casual blood pressure measurements, 24-hour monitoring showed normal blood pressure in 21-47%, so this is the rate of white coat hypertension. Masked hypertension can also be diagnosed with the help of this method, which has a prevalence of 7-11%. We can also get useful data for secondary forms of hypertension. Until the appearance of the new European guidelines, more frequent use of ambulatory blood pressure monitoring is affordable. The confirmation of the diagnosis based on elevated casual blood pressure data is important. Ambulatory blood pressure monitoring is suggested in cases suspicious for white coat or masked hypertension, in cases of target organ damages or therapy resistant hypertension. Before administration of pharmaceutical therapy in adolescence hypertension - according to author's opinion - ambulatory blood pressure monitoring is absolutely necessary.

  19. Stress and High Blood Pressure: What's the Connection?

    MedlinePlus

    Stress and high blood pressure: What's the connection? Stress and long-term high blood pressure may not be linked, but taking steps to reduce your stress can improve your general health, including your blood ...

  20. Rotator cuff crepitus: could Codman really feel a cuff tear?

    PubMed

    Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J

    2014-07-01

    The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.

  1. A survey of blood pressure in Lebanese children and adolescence

    PubMed Central

    Merhi, Bassem Abou; Al-Hajj, Fatima; Al-Tannir, Mohamad; Ziade, Fouad; El-Rajab, Mariam

    2011-01-01

    Background: Blood pressure varies between populations due to ethnic and environmental factors. Therefore, normal blood pressure values should be determined for different populations. Aims: The aim of this survey was to produce blood pressure nomograms for Lebanese children in order to establish distribution curves of blood pressure by age and sex. Subjects and Methods: We conducted a survey of blood pressure in 5710 Lebanese schoolchildren aged 5 to 15 years (2918 boys and 2792 girls), and studied the distribution of systolic and diastolic blood pressure in these children and adolescents. Blood pressure was measured with a mercury sphygmomanometer using a standardized technique. Results: Both systolic and diastolic blood pressure had a positive correlation with weight, height, age, and body mass index (r= 0.648, 0.643, 0.582, and 0.44, respectively) (P < .001). There was no significant difference in the systolic and diastolic blood pressure in boys compared to girls of corresponding ages. However, the average annual increase in systolic blood pressure was 2.86 mm Hg in boys and 2.63 mm Hg in girls, whereas the annual increase in diastolic blood pressure was 1.72 mm Hg in boys and 1.48 mm Hg in girls. The prevalence of high and high-normal blood pressure at the upper limit of normal (between the 90th and 95th percentile, at risk of future hypertension if not managed adequately), was 10.5% in boys and 6.9% in girls, with similar distributions among the two sexes. Conclusions: We present the first age-specific reference values for blood pressure of Lebanese children aged 5 to 15 years based on a good representative sample. The use of these reference values should help pediatricians identify children with normal, high-normal and high blood pressure. PMID:22540059

  2. A survey of blood pressure in Lebanese children and adolescence.

    PubMed

    Merhi, Bassem Abou; Al-Hajj, Fatima; Al-Tannir, Mohamad; Ziade, Fouad; El-Rajab, Mariam

    2011-01-01

    Blood pressure varies between populations due to ethnic and environmental factors. Therefore, normal blood pressure values should be determined for different populations. The aim of this survey was to produce blood pressure nomograms for Lebanese children in order to establish distribution curves of blood pressure by age and sex. We conducted a survey of blood pressure in 5710 Lebanese schoolchildren aged 5 to 15 years (2918 boys and 2792 girls), and studied the distribution of systolic and diastolic blood pressure in these children and adolescents. Blood pressure was measured with a mercury sphygmomanometer using a standardized technique. Both systolic and diastolic blood pressure had a positive correlation with weight, height, age, and body mass index (r= 0.648, 0.643, 0.582, and 0.44, respectively) (P < .001). There was no significant difference in the systolic and diastolic blood pressure in boys compared to girls of corresponding ages. However, the average annual increase in systolic blood pressure was 2.86 mm Hg in boys and 2.63 mm Hg in girls, whereas the annual increase in diastolic blood pressure was 1.72 mm Hg in boys and 1.48 mm Hg in girls. The prevalence of high and high-normal blood pressure at the upper limit of normal (between the 90(th) and 95(th) percentile, at risk of future hypertension if not managed adequately), was 10.5% in boys and 6.9% in girls, with similar distributions among the two sexes. We present the first age-specific reference values for blood pressure of Lebanese children aged 5 to 15 years based on a good representative sample. The use of these reference values should help pediatricians identify children with normal, high-normal and high blood pressure.

  3. Goat Meat Does Not Cause Increased Blood Pressure

    PubMed Central

    Sunagawa, Katsunori; Kishi, Tetsuya; Nagai, Ayako; Matsumura, Yuka; Nagamine, Itsuki; Uechi, Shuntoku

    2014-01-01

    While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g) were evenly separated into 4 groups. The control group (CP) was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM) was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS) was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan)/salt group (GY) was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (p<0.01) than the CP and GM groups despite the fact that their diet consumption levels were similar. The body weight of animals in the CP, GM, and GS groups was similar while the animals in the GY group were significantly smaller (p<0.01). The blood pressure in the GM group was virtually the same as the CP group throughout the course of the experiment. In contrast, while the blood pressure of the animals in the GS and GY group from 15 to 19 weeks old was the same as the CP group, their blood pressures were significantly higher (p<0.01) after 20 weeks of age. The GY group tended to have lower blood pressure than the GS group. In experiment 2, in order to clarify whether or not the increase in blood pressure in the GS group and the GY group in experiment 1 was caused by an excessive intake of salt, the effects on blood pressure of a reduction of salt in diet were investigated. When amount of salt in the diet of the GS and GY group was reduced from 4% to 0.3%, the animal’s blood pressure

  4. Goat meat does not cause increased blood pressure.

    PubMed

    Sunagawa, Katsunori; Kishi, Tetsuya; Nagai, Ayako; Matsumura, Yuka; Nagamine, Itsuki; Uechi, Shuntoku

    2014-01-01

    While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g) were evenly separated into 4 groups. The control group (CP) was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM) was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS) was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan)/salt group (GY) was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (p<0.01) than the CP and GM groups despite the fact that their diet consumption levels were similar. The body weight of animals in the CP, GM, and GS groups was similar while the animals in the GY group were significantly smaller (p<0.01). The blood pressure in the GM group was virtually the same as the CP group throughout the course of the experiment. In contrast, while the blood pressure of the animals in the GS and GY group from 15 to 19 weeks old was the same as the CP group, their blood pressures were significantly higher (p<0.01) after 20 weeks of age. The GY group tended to have lower blood pressure than the GS group. In experiment 2, in order to clarify whether or not the increase in blood pressure in the GS group and the GY group in experiment 1 was caused by an excessive intake of salt, the effects on blood pressure of a reduction of salt in diet were investigated. When amount of salt in the diet of the GS and GY group was reduced from 4% to 0.3%, the animal's blood pressure

  5. 21 CFR 870.1130 - Noninvasive blood pressure measurement system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Noninvasive blood pressure measurement system. 870... Noninvasive blood pressure measurement system. (a) Identification. A noninvasive blood pressure measurement... three pressures can be derived through the use of tranducers placed on the surface of the body. (b...

  6. 21 CFR 870.1130 - Noninvasive blood pressure measurement system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Noninvasive blood pressure measurement system. 870... Noninvasive blood pressure measurement system. (a) Identification. A noninvasive blood pressure measurement... three pressures can be derived through the use of tranducers placed on the surface of the body. (b...

  7. 21 CFR 870.1130 - Noninvasive blood pressure measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Noninvasive blood pressure measurement system. 870... Noninvasive blood pressure measurement system. (a) Identification. A noninvasive blood pressure measurement... three pressures can be derived through the use of tranducers placed on the surface of the body. (b...

  8. 21 CFR 870.1130 - Noninvasive blood pressure measurement system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Noninvasive blood pressure measurement system. 870... Noninvasive blood pressure measurement system. (a) Identification. A noninvasive blood pressure measurement... three pressures can be derived through the use of tranducers placed on the surface of the body. (b...

  9. Health Instruction Packages: How to Take a Blood Pressure.

    ERIC Educational Resources Information Center

    Lancaster, Carolyn; And Others

    Text, illustrations, and exercises are utilized in these four learning modules to teach dental hygiene students, nursing students, and the general public how to measure blood pressure. The first module, "Can You Take a Blood Pressure?" by Carolyn Lancaster, defines blood pressure, distinguishes between systolic and diastolic pressure and…

  10. Arthroscopic trans-osseous rotator cuff repair

    PubMed Central

    Chillemi, Claudio; Mantovani, Matteo

    2017-01-01

    Summary Background: Mechanical factors are at the basis of any tendon healing process, being pressure an aspect able to positively influence it. For this reason transosseous rotator cuff repair represents the gold standard procedure for patients affected by a cuff tear, maximizing the tendon footprint contact area and reducing motion at the tendon to bone interface. Methods: The Authors present an all arthroscopic suture bridge-like transosseous repair with the preparation of a single transosseous tunnel perfor med thanks to a precise dedicated instrument (Compasso®) and one implant (Elite-SPK®) with the use of only 3 suture wires. In addition this technique permits to accurately prepare the bony side of the lesion without any risk or complication, such as anchor pull-out and greater tuberosity bone osteolysis. Conclusions: However, even if this technique seems less demanding, the arthroscopic transosseous repair is still an advanced procedure, and should be performed only by well prepared arthroscopic shoulder surgeons. Level of evidence: V. PMID:28717607

  11. Blood pressure in head‐injured patients

    PubMed Central

    Mitchell, Patrick; Gregson, Barbara A; Piper, Ian; Citerio, Giuseppe; Mendelow, A David; Chambers, Iain R

    2007-01-01

    Objective To determine the statistical characteristics of blood pressure (BP) readings from a large number of head‐injured patients. Methods The BrainIT group has collected high time‐resolution physiological and clinical data from head‐injured patients who require intracranial pressure (ICP) monitoring. The statistical features of this dataset of BP measurements with time resolution of 1 min from 200 patients is examined. The distributions of BP measurements and their relationship with simultaneous ICP measurements are described. Results The distributions of mean, systolic and diastolic readings are close to normal with modest skewing towards higher values. There is a trend towards an increase in blood pressure with advancing age, but this is not significant. Simultaneous blood pressure and ICP values suggest a triphasic relationship with a BP rising at 0.28 mm Hg/mm Hg of ICP, for ICP up to 32 mm Hg, and 0.9 mm Hg/mm Hg of ICP for ICP from 33 to 55 mm Hg, and falling sharply with rising ICP for ICP >55 mm Hg. Conclusions Patients with head injury appear to have a near normal distribution of blood pressure readings that are skewed towards higher values. The relationship between BP and ICP may be triphasic. PMID:17138594

  12. Blood pressure variability in man: its relation to high blood pressure, age and baroreflex sensitivity.

    PubMed

    Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A

    1980-12-01

    1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.

  13. Aerobic exercise reduces blood pressure in resistant hypertension.

    PubMed

    Dimeo, Fernando; Pagonas, Nikolaos; Seibert, Felix; Arndt, Robert; Zidek, Walter; Westhoff, Timm H

    2012-09-01

    Regular physical exercise is broadly recommended by current European and American hypertension guidelines. It remains elusive, however, whether exercise leads to a reduction of blood pressure in resistant hypertension as well. The present randomized controlled trial examines the cardiovascular effects of aerobic exercise on resistant hypertension. Resistant hypertension was defined as a blood pressure ≥140/90 mm Hg in spite of 3 antihypertensive agents or a blood pressure controlled by ≥4 antihypertensive agents. Fifty subjects with resistant hypertension were randomly assigned to participate or not to participate in an 8- to 12-week treadmill exercise program (target lactate, 2.0±0.5 mmol/L). Blood pressure was assessed by 24-hour monitoring. Arterial compliance and cardiac index were measured by pulse wave analysis. The training program was well tolerated by all of the patients. Exercise significantly decreased systolic and diastolic daytime ambulatory blood pressure by 6±12 and 3±7 mm Hg, respectively (P=0.03 each). Regular exercise reduced blood pressure on exertion and increased physical performance as assessed by maximal oxygen uptake and lactate curves. Arterial compliance and cardiac index remained unchanged. Physical exercise is able to decrease blood pressure even in subjects with low responsiveness to medical treatment. It should be included in the therapeutic approach to resistant hypertension.

  14. Non-linear Heart Rate and Blood Pressure Interaction in Response to Lower-Body Negative Pressure

    PubMed Central

    Verma, Ajay K.; Xu, Da; Garg, Amanmeet; Cote, Anita T.; Goswami, Nandu; Blaber, Andrew P.; Tavakolian, Kouhyar

    2017-01-01

    Early detection of hemorrhage remains an open problem. In this regard, blood pressure has been an ineffective measure of blood loss due to numerous compensatory mechanisms sustaining arterial blood pressure homeostasis. Here, we investigate the feasibility of causality detection in the heart rate and blood pressure interaction, a closed-loop control system, for early detection of hemorrhage. The hemorrhage was simulated via graded lower-body negative pressure (LBNP) from 0 to −40 mmHg. The research hypothesis was that a significant elevation of causal control in the direction of blood pressure to heart rate (i.e., baroreflex response) is an early indicator of central hypovolemia. Five minutes of continuous blood pressure and electrocardiogram (ECG) signals were acquired simultaneously from young, healthy participants (27 ± 1 years, N = 27) during each LBNP stage, from which heart rate (represented by RR interval), systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) were derived. The heart rate and blood pressure causal interaction (RR↔SBP and RR↔MAP) was studied during the last 3 min of each LBNP stage. At supine rest, the non-baroreflex arm (RR→SBP and RR→MAP) showed a significantly (p < 0.001) higher causal drive toward blood pressure regulation compared to the baroreflex arm (SBP→RR and MAP→RR). In response to moderate category hemorrhage (−30 mmHg LBNP), no change was observed in the traditional marker of blood loss i.e., pulse pressure (p = 0.10) along with the RR→SBP (p = 0.76), RR→MAP (p = 0.60), and SBP→RR (p = 0.07) causality compared to the resting stage. Contrarily, a significant elevation in the MAP→RR (p = 0.004) causality was observed. In accordance with our hypothesis, the outcomes of the research underscored the potential of compensatory baroreflex arm (MAP→RR) of the heart rate and blood pressure interaction toward differentiating a simulated moderate category hemorrhage from

  15. Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation.

    PubMed

    Lee, Joonnyong; Sohn, JangJay; Park, Jonghyun; Yang, SeungMan; Lee, Saram; Kim, Hee Chan

    2018-06-18

    Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension, but not enough attention has been given to non-invasive continuous monitoring of pulse pressure. Although accurate pulse pressure estimation can be of direct value to hypertension management and indirectly to the estimation of systolic blood pressure, as it is the sum of pulse pressure and diastolic blood pressure, only a few inadequate methods of pulse pressure estimation have been proposed. We present a novel, non-invasive blood pressure and pulse pressure estimation method based on pulse transit time and pre-ejection period. Pre-ejection period and pulse transit time were measured non-invasively using electrocardiogram, seismocardiogram, and photoplethysmogram measured from the torso. The proposed method used the 2-element Windkessel model to model pulse pressure with the ratio of stroke volume, approximated by pre-ejection period, and arterial compliance, estimated by pulse transit time. Diastolic blood pressure was estimated using pulse transit time, and systolic blood pressure was estimated as the sum of the two estimates. The estimation method was verified in 11 subjects in two separate conditions with induced cardiovascular response and the results were compared against a reference measurement and values obtained from a previously proposed method. The proposed method yielded high agreement with the reference (pulse pressure correlation with reference R ≥ 0.927, diastolic blood pressure correlation with reference R ≥ 0.854, systolic blood pressure correlation with reference R ≥ 0.914) and high estimation accuracy in pulse pressure (mean root-mean-squared error ≤ 3.46 mmHg) and blood pressure (mean root-mean-squared error ≤ 6.31 mmHg for diastolic blood pressure and ≤ 8.41

  16. Rehabilitation after Rotator Cuff Repair.

    PubMed

    Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos

    2017-01-01

    Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.

  17. SPAKling insight into blood pressure regulation

    PubMed Central

    Castañeda-Bueno, María; Gamba, Gerardo

    2010-01-01

    Arterial hypertension is one of the most important health problems in industrialized cities. Blood pressure levels are influenced by renal salt handling and salt reabsorption in the kidney. In this Closeup, Castañeda-Bueno and Gamba discuss the work from Alessi and coworkers on the in vivo roles of the SPAK kinase in defining blood pressure levels. PMID:20112249

  18. Rolling-cuff flexible bellows

    DOEpatents

    Lambert, D.R.

    1982-09-27

    A flexible connector apparatus used to join two stiff non-deformable members, such as piping, is described. The apparatus is provided with one or more flexible sections or assemblies each utilizing a bellows of a rolling cuff type connected between two ridge members, with the bellows being supported by a back-up ring, such that only the curved end sections of the bellows are unsupported. Thus, the bellows can be considered as being of a tube-shaped configuration and thus have high pressure resistance. The components of the flexible apparatus are sealed or welded one to another such that it is fluid tight.

  19. Blood pressure-lowering treatment strategies based on cardiovascular risk versus blood pressure: A meta-analysis of individual participant data

    PubMed Central

    Karmali, Kunal N.; Lloyd-Jones, Donald M.; Zanchetti, Alberto; Jackson, Rodney; Woodward, Mark; Neal, Bruce C.; Berge, Eivind; Teo, Koon; Davis, Barry R.; Pepine, Carl

    2018-01-01

    Background Clinical practice guidelines have traditionally recommended blood pressure treatment based primarily on blood pressure thresholds. In contrast, using predicted cardiovascular risk has been advocated as a more effective strategy to guide treatment decisions for cardiovascular disease (CVD) prevention. We aimed to compare outcomes from a blood pressure-lowering treatment strategy based on predicted cardiovascular risk with one based on systolic blood pressure (SBP) level. Methods and findings We used individual participant data from the Blood Pressure Lowering Treatment Trialists’ Collaboration (BPLTTC) from 1995 to 2013. Trials randomly assigned participants to either blood pressure-lowering drugs versus placebo or more intensive versus less intensive blood pressure-lowering regimens. We estimated 5-y risk of CVD events using a multivariable Weibull model previously developed in this dataset. We compared the two strategies at specific SBP thresholds and across the spectrum of risk and blood pressure levels studied in BPLTTC trials. The primary outcome was number of CVD events avoided per persons treated. We included data from 11 trials (47,872 participants). During a median of 4.0 y of follow-up, 3,566 participants (7.5%) experienced a major cardiovascular event. Areas under the curve comparing the two treatment strategies throughout the range of possible thresholds for CVD risk and SBP demonstrated that, on average, a greater number of CVD events would be avoided for a given number of persons treated with the CVD risk strategy compared with the SBP strategy (area under the curve 0.71 [95% confidence interval (CI) 0.70–0.72] for the CVD risk strategy versus 0.54 [95% CI 0.53–0.55] for the SBP strategy). Compared with treating everyone with SBP ≥ 150 mmHg, a CVD risk strategy would require treatment of 29% (95% CI 26%–31%) fewer persons to prevent the same number of events or would prevent 16% (95% CI 14%–18%) more events for the same number of

  20. Lower Blood Pressure-Induced Renal Hypoperfusion Promotes Cisplatin-Induced Nephrotoxicity.

    PubMed

    Mizuno, Tomohiro; Hayashi, Takahiro; Shimabukuro, Yuka; Murase, Maho; Hayashi, Hiroki; Ishikawa, Kazuhiro; Takahashi, Kazuo; Yuzawa, Yukio; Yamada, Shigeki; Nagamatsu, Tadashi

    2016-01-01

    Cisplatin-induced nephrotoxicity primarily occurs in the proximal tubules, and tubular injuries reduce glomerular filtration rates. Lower blood pressure causes renal hypoperfusion, which promotes ischemic acute kidney injury (AKI). Our study examined the relationship between lower blood pressure-induced renal hypoperfusion and cisplatin-induced nephrotoxicity. The relationship between cisplatin use and hypoalbuminemia is not clear. This study consisted of Japanese patients who received cisplatin as the first-line chemotherapy at Fujita Health University Hospital from April 2006 to December 2012. Hypoalbuminemia was defined as serum albumin levels ≤3.5 mg/dl. Patients who experienced lower blood pressure during chemotherapy were included in the lower blood pressure group (n = 229), and those who did not were included in the normal blood pressure group (n = 743). Total cisplatin dose in the normal blood pressure and lower blood pressure groups was 58.9 ± 23.8 and 55.0 ± 20.4 mg/m2, respectively. The rate of severe nephrotoxicity was higher and overall survival was shorter in the lower blood pressure group than in the normal blood pressure group. In a multivariable analysis, lower blood pressure significantly correlated with hypoalbuminemia. To prevent ischemic AKI, nutrition and cachexia controlling are important parts of cancer treatment. © 2016 S. Karger AG, Basel.

  1. Reducing the Blood Pressure-Related Burden of Cardiovascular Disease: Impact of Achievable Improvements in Blood Pressure Prevention and Control.

    PubMed

    Hardy, Shakia T; Loehr, Laura R; Butler, Kenneth R; Chakladar, Sujatro; Chang, Patricia P; Folsom, Aaron R; Heiss, Gerardo; MacLehose, Richard F; Matsushita, Kunihiro; Avery, Christy L

    2015-10-27

    US blood pressure reduction policies are largely restricted to hypertensive populations and associated benefits are often estimated based on unrealistic interventions. We used multivariable linear regression to estimate incidence rate differences contrasting the impact of 2 pragmatic hypothetical interventions to reduce coronary heart disease, stroke, and heart failure (HF) incidence: (1) a population-wide intervention that reduced systolic blood pressure by 1 mm Hg and (2) targeted interventions that reduced the prevalence of unaware, untreated, or uncontrolled blood pressure above goal (per Eighth Joint National Committee treatment thresholds) by 10%. In the Atherosclerosis Risk in Communities Study (n=15 744; 45 to 64 years at baseline, 1987-1989), incident coronary heart disease and stroke were adjudicated by physician panels. Incident HF was defined as the first hospitalization with discharge diagnosis code of "428." A 10% proportional reduction in unaware, untreated, or uncontrolled blood pressure above goal resulted in ≈4.61, 3.55, and 11.01 fewer HF events per 100,000 person-years in African Americans, and 3.77, 1.63, and 4.44 fewer HF events per 100 000 person-years, respectively, in whites. In contrast, a 1 mm Hg population-wide systolic blood pressure reduction was associated with 20.3 and 13.3 fewer HF events per 100 000 person-years in African Americans and whites, respectively. Estimated event reductions for coronary heart disease and stroke were smaller than for HF, but followed a similar pattern for both population-wide and targeted interventions. Modest population-wide shifts in systolic blood pressure could have a substantial impact on cardiovascular disease incidence and should be developed in parallel with interventions targeting populations with blood pressure above goal. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Sleep disturbance associated with rotator cuff tear: correction with arthroscopic rotator cuff repair.

    PubMed

    Austin, Luke; Pepe, Matthew; Tucker, Bradford; Ong, Alvin; Nugent, Robert; Eck, Brandon; Tjoumakaris, Fotios

    2015-06-01

    Sleep disturbance is a common complaint of patients with a rotator cuff tear. Inadequate and restless sleep, along with pain, is often a driving symptom for patients to proceed with rotator cuff repair. To date, no studies have examined sleep disturbance in patients undergoing rotator cuff repair, and there is no evidence that surgery improves sleep disturbance. Sleep disturbance is prevalent in patients with a symptomatic rotator cuff tear, and sleep disturbance improves after arthroscopic rotator cuff repair. Case series; Level of evidence, 4. A total of 56 patients undergoing arthroscopic rotator cuff repair for full-thickness tears were enrolled in a prospective study. Patients were surveyed preoperatively and postoperatively at intervals of 2, 6, 12, 18, and 24 weeks. Patient outcomes were scored using the Pittsburgh Sleep Quality Index (PSQI), Simple Shoulder Test (SST), visual analog scale for pain (VAS), and single assessment numeric evaluation (SANE). Demographic and surgical factors were also collected for analysis. Preoperative PSQI scores indicative of sleep disturbance were reported in 89% of patients. After surgery, a statistically significant improvement in PSQI was achieved at 3 months (P = .0012; 91% follow-up) and continued through 6 months (P = .0179; 93% follow-up). Six months after surgery, only 38% of patients continued to have sleep disturbance. Multivariable linear regression of all surgical and demographic factors versus PSQI was performed and demonstrated that preoperative and prolonged postoperative narcotic use negatively affected sleep. Sleep disturbance is common in patients undergoing rotator cuff repair. After surgery, sleep disturbance improves to levels comparable with those of the general public. Preoperative and prolonged postoperative use of narcotic pain medication negatively affects sleep. © 2015 The Author(s).

  3. The effects of increasing levels of dietary garlic bulb on growth performance, systolic blood pressure, hematology, and ascites syndrome in broiler chickens.

    PubMed

    Varmaghany, Saifali; Karimi Torshizi, Mohammad Amir; Rahimi, Shaban; Lotfollahian, Houshang; Hassanzadeh, Mohammad

    2015-08-01

    The effects of dietary garlic bulb were studied separately on hematological parameters, ascites incidence, and growth performance of an ascites susceptible broiler hybrid under both standard temperature conditions ( STC: ) and cold temperature conditions ( CTC: ). A total of 336 one-day-old male broiler chickens were allocated to 4 experimental groups with 4 replicates of 21 birds each under STC. In addition, the same grouping with another 336 birds was used for CTC. Under CTC, the birds were exposed to cold temperatures for induction of ascites. Experimental groups were defined by the inclusion of 0 (control), 5, 10 or 15 g/kg garlic bulbs in the diets under both STC and CTC. Growth performance, systolic blood pressure (as a measure of systemic arterial blood pressure), physiological and biochemical parameters, as well as ascites indices (right ventricle [ RV: ], total ventricle [ TV: ] weights, and RV/TV: ) were evaluated. Systolic blood pressure was determined using an indirect method with a sphygmomanometer, a pediatric cuff, and a Doppler device. The final body weight decreased quadratically (P = 0.003), with increasing garlic bulb levels in the diets under STC. The feed conversion ratio showed no significant differences among all groups under both STC and CTC. No significant differences were observed in total mortality and ascites-related mortality in all groups under STC, although total mortality (L: P = 0.01; Q: P = 0.001) and ascites-related mortality (L: P = 0.007; Q: P = 0.001) were significantly different among the diets under CTC. Under STC, the systolic blood pressure, packed cell volume, hemoglobin, RV, TV, and RV/TV did not vary significantly among the diets. However, red blood cell count and erythrocyte osmotic fragility decreased linearly (P < 0.005) with increasing garlic bulb levels in the diets under STC. Under CTC, the systolic blood pressure, packed cell volume, red blood cell count, and erythrocyte osmotic fragility decreased

  4. A Pilot Study: Comparison of Arm Versus Ankle Noninvasive Blood Pressure Measurement at 2 Different Levels of Backrest Elevation.

    PubMed

    Henley, Nicole; Quatrara, Beth D; Conaway, Mark

    2015-01-01

    Standard practice for obtaining noninvasive blood pressure includes arm blood pressure (BP) cuff placement at the level of the heart; however, some critical care patients cannot have BPs taken in their arm because of various conditions, and ankle BPs are frequently used as substitutes. The aim of this study was to determine if there was a significant variation between upper arm and ankle BP measurements at different backrest elevations with consideration of peripheral edema factors. After institutional review board approval was obtained, a pilot study was implemented to evaluate noninvasive BP measurements of the arm and ankle with backrest elevation at 0° and 30° in a population of medical intensive care unit patients. Participants served as their own controls and were randomly assigned to left- versus right-side BP readings. Data were also collected on presence of arm versus ankle edema. A total of 30 participants enrolled in the study and provided 120 BP measurements. Blood pressure readings were analyzed in terms of diastolic and systolic findings as well as backrest elevations and edema presence. Thirteen participants presented with either arm or ankle edema. There was a statistical difference between the systolic arm and ankle BP measurements in the 0° (P = .008) and 30° (P < .001) backrest elevation positions. The correlation between arm and ankle diastolic BP is greater for participants without ankle edema (P = .038, r = 0.54) than for participants with ankle edema (P = .650, r = 0.14), but it is not statistically significant (P = .47). Even though ankle BPs are often substituted for arm BPs when the arm is unable to be used, ankle BPs and arm BPs are not interchangeable. Adjustments in backrest elevation and considerations of edema do not normalize the differences. Blood pressures obtained from the ankle are significantly greater than those obtained from the arm. This information needs to be considered when arms are not available and legs are used as

  5. Previous blood pressure measurement and associated factors in student adolescents

    PubMed Central

    Magalhães, Marina Gabriella Pereira de Andrada; Farah, Breno Quintella; de Barros, Mauro Virgilio Gomes; Ritti-Dias, Raphael Mendes

    2015-01-01

    Objective To identify prevalence of previous blood pressure measurement and analyze some associated factors in adolescents. Methods This cross-sectional study included 6,077 adolescents aged 14 to 19 years. Demographic characteristics included (sex, age, period of study, region of residence, work, skin color, and economic) status, history of blood pressure measurement within last 12 months, local of blood pressure measurement, and reading obtained. To assess associations between previous blood pressure measurement with demographic characteristics and high blood pressure we used descriptive statistics and logistic regression analysis. Results Out of the adolescents, 56.8% reported no blood pressure measurement within the last 12 months. The health centers and the physician’s office were most mentioned places for blood pressure measurement (28.3% and 36.9%, respectively). Boys (odds ratio of 1.64 95%CI: 1.46-1.84) aged 14 to 16 years (odds ratio of 1.12; 95%CI: 1.01-1.25), whose economic status was unfavorable (odds ratio of 1.48; 95%CI: 1.32-1.67) were significantly associated with no blood pressure measurement. Working was a protective factor for was not blood pressure measurement (odds ratio of 0.84; 95%CI: 0.73-0.97). Conclusion Most of adolescents did not have their blood pressure measured within the last 12 months. Boys aged 14 to 16 years and those with unfavorable economic status had higher chance of not having their blood pressure measured. PMID:26466061

  6. Correlates of blood pressure in Yanomami Indians of northwestern Brazil.

    PubMed

    Crews, D E; Mancilha-Carvalho, J J

    1993-01-01

    We determined associations of measures of body habitus with blood pressure for 100 adult Yanomami Indians (61 men, 39 women) examined during February and March 1990. Measurements included body weight and height, four skinfolds (triceps, subscapular, suprailiac, abdomen), four circumferences (wrist, upper arm, abdomen, hip), systolic and diastolic blood pressures, pulse rate, and estimated age. Various indices of fat distribution were determined from the measurements of skinfolds, circumferences, weight, and height. Estimated age averaged 35.0 years in men and 33.4 years in women (range: 15 to 63 years). Mean systolic and diastolic blood pressures were low in both men (104.8/70.4 mm Hg) and women (94.8/63.5 mm Hg), as was body mass index (men: 20.7; women: 21.4 kg/m2). In Yanomami women, all four skinfolds, wrist circumference, and the indices of hip and abdominal fat were significant correlates of systolic blood pressure, while the abdominal skinfold and wrist and hip circumferences correlated significantly with diastolic blood pressure. Among men, there was a negative correlation between estimated age and systolic blood pressure and a positive correlation between BMI and upper arm and hip circumferences and systolic blood pressure. There was a significant positive correlation between wrist, upper arm, and hip circumferences and diastolic blood pressure among Yanomami men. We used stepwise regression to generate sex-specific predictive equations for blood pressure. For men, estimated age and hip circumference, and for women, abdominal skinfold measurement and age were included in the model for systolic blood pressure. Among men, wrist circumference and height, and among women, wrist circumference alone entered the model for diastolic blood pressure. On the basis of these results, we suggest that even in a low-blood pressure, low-body fat, no-salt setting, systolic blood pressure is associated with the amount and placement of adipose tissue. However, diastolic blood

  7. Effects of Parental Smoking on Exercise Systolic Blood Pressure in Adolescents

    PubMed Central

    Hacke, Claudia; Weisser, Burkhard

    2015-01-01

    Background In adults, exercise blood pressure seems to be more closely related to cardiovascular risk than resting blood pressure; however, few data are available on the effects of familial risk factors, including smoking habits, on exercise blood pressure in adolescents. Methods and Results Blood pressure at rest and during exercise, parental smoking, and other familial risk factors were investigated in 532 adolescents aged 12 to 17 years (14.6±1.5 years) in the Kiel EX.PRESS. (EXercise PRESSure) Study. Exercise blood pressure was determined at 1.5 W/kg body weight using a standardized submaximal cycle ergometer test. Mean resting blood pressure was 113.1±12.8/57.2±7.1 mm Hg, and exercise blood pressure was 149.9±19.8/54.2±8.6 mm Hg. Parental smoking increased exercise systolic blood pressure (+4.0 mm Hg, 3.1 to 4.9; P=0.03) but not resting blood pressure of the subjects (adjusted for age, sex, height, body mass index percentile, fitness). Parental overweight and familial hypertension were related to both higher resting and exercise systolic blood pressure values, whereas associations with an inactive lifestyle and a low educational level of the parents were found only with adolescents’ blood pressure during exercise. The cumulative effect of familial risk factors on exercise systolic blood pressure was more pronounced than on blood pressure at rest. Conclusions Parental smoking might be a novel risk factor for higher blood pressure, especially during exercise. In addition, systolic blood pressure during a submaximal exercise test was more closely associated with familial risk factors than was resting blood pressure, even in adolescents. PMID:25964207

  8. Effects of parental smoking on exercise systolic blood pressure in adolescents.

    PubMed

    Hacke, Claudia; Weisser, Burkhard

    2015-05-11

    In adults, exercise blood pressure seems to be more closely related to cardiovascular risk than resting blood pressure; however, few data are available on the effects of familial risk factors, including smoking habits, on exercise blood pressure in adolescents. Blood pressure at rest and during exercise, parental smoking, and other familial risk factors were investigated in 532 adolescents aged 12 to 17 years (14.6±1.5 years) in the Kiel EX.PRESS. (EXercise PRESSure) Study. Exercise blood pressure was determined at 1.5 W/kg body weight using a standardized submaximal cycle ergometer test. Mean resting blood pressure was 113.1±12.8/57.2±7.1 mm Hg, and exercise blood pressure was 149.9±19.8/54.2±8.6 mm Hg. Parental smoking increased exercise systolic blood pressure (+4.0 mm Hg, 3.1 to 4.9; P=0.03) but not resting blood pressure of the subjects (adjusted for age, sex, height, body mass index percentile, fitness). Parental overweight and familial hypertension were related to both higher resting and exercise systolic blood pressure values, whereas associations with an inactive lifestyle and a low educational level of the parents were found only with adolescents' blood pressure during exercise. The cumulative effect of familial risk factors on exercise systolic blood pressure was more pronounced than on blood pressure at rest. Parental smoking might be a novel risk factor for higher blood pressure, especially during exercise. In addition, systolic blood pressure during a submaximal exercise test was more closely associated with familial risk factors than was resting blood pressure, even in adolescents. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Attenuation in invasive blood pressure measurement systems.

    PubMed

    Ercole, A

    2006-05-01

    Poor fidelity invasive arterial blood pressure (IABP) traces are a frequent practical problem. It is common practice to describe any such trace as being 'damped'; the resonance behaviour of IABP measurement systems having been extensively described in the literature. However, as poor quality arterial blood pressure signals are seen even with optimal pressure transduction circuits, this cannot be the sole mechanism. In this commentary the classical lumped-parameter Windkessel model is extended by postulating an additional impedance proximal to the site of IABP measurement. This impedance represents any mechanical obstruction to laminar flow. Equations are presented relating measured and actual arterial blood pressures in terms of the model impedances. The reactive properties of such a partial obstruction may lead to an IABP trace that is superficially similar in appearance to the case of an over-damped measurement system. However, this phenomenon should be termed 'attenuation' rather than 'damping' and is probably more common. The distinction is of practical importance as the behaviour of the measured systolic and diastolic pressures is different -- both are systematically underestimated and the mean arterial pressure is thus not preserved. Furthermore, this error varies inversely with the peripheral vascular resistance of the tissues distal to the measurement point, therefore apparently magnifying the effect of vasodilatation on blood pressure or derived quantities.

  10. Relations of Blood Pressure and Head Injury to Regional Cerebral Blood Flow

    PubMed Central

    Allen, Allyssa J.; Katzel, Leslie I.; Wendell, Carrington R.; Siegel, Eliot L.; Lefkowitz, David; Waldstein, Shari R.

    2016-01-01

    Hypertension confers increased risk for cognitive decline, dementia, and cerebrovascular disease. These associations have been attributed, in part, to cerebral hypoperfusion. Here we posit that relations of higher blood pressure to lower levels of cerebral perfusion may be potentiated by a prior head injury. Participants were 87 community-dwelling older adults -69% men, 90% white, mean age= 66.9 years, 27.6% with a history of mild traumatic brain injury (mTBI) defined as a loss of consciousness blood pressure (SBP, DBP) and single photon emission computed tomography (SPECT). Computerized coding of the SPECT images yielded relative ratios of blood flow in left and right cortical and select subcortical regions. Cerebellum served as the denominator. Sex-stratified multiple regression analyses, adjusted for age, education, race, alcohol consumption, smoking status, and depressive symptomatology, revealed significant interactions of blood pressure and head injury to cerebral blood flow in men only. Specifically, among men with a history of head injury, higher systolic blood pressure was associated with lower levels of perfusion in the left orbital (β=-3.21, p=.024) and left dorsolateral (β=-2.61, p=.042) prefrontal cortex, and left temporal cortex (β=-3.36, p=.014); higher diastolic blood pressure was marginally associated with lower levels of perfusion in the left dorsolateral prefrontal cortex (β=-2.79, p=.051). Results indicate that men with a history of head injury may be particularly vulnerable to the impact of higher blood pressure on cerebral perfusion in left anterior cortical regions, thus potentially enhancing risk for adverse brain and neurocognitive outcomes. PMID:27206865

  11. Blood pressure reactivity in the evaluation of resting blood pressure and mood responses to pindolol and propranolol in hypertensive patients.

    PubMed

    Potempa, K M; Fogg, L F; Fish, A F; Kravitz, H M

    1993-01-01

    The purpose of this exploratory study was to evaluate the relationship of blood pressure reactivity during exercise to treatment responsiveness to two commonly used beta-adrenergic blocking agents, propranolol and pindolol. Prospective, placebo-controlled, balanced, cross-over clinical trial. University-affiliated medical center. A convenience sample of 19 white male subjects with mild to moderate essential hypertension were studied. The mean age was 63.4 years (SD = 5.2). The mean resting systolic blood pressure (SBP) was 158.6 mm Hg (SD = 12.3) and mean resting diastolic blood pressure (DBP) was 96.4 mm Hg (SD = 8.6). They had no clinical evidence of secondary hypertension, diabetes, heart, liver, pulmonary, or renal disease. Resting blood pressure; blood pressure reactivity to exercise; self-report measures of depressive symptoms, and mood disturbances. Antihypertensive medication was tapered off and subjects were free of all prescription drugs for 2 weeks. Subjects were randomly assigned to propranolol-pindolol or pindolol-propranolol group. Each 4- to 6-week treatment phase was preceded by a 2-week placebo phase. At the end of the initial placebo phase and each active drug treatment phase, subjects were assessed for depression and mood disturbances by use of standardized measures and were given a graded exercise test on a cycle ergometer. Resting blood pressure was assessed weekly and before each exercise test. Significant relationships between DBP reactivity to exercise during the placebo phase and the degree of blood pressure and mood responsiveness to pindolol and propranolol treatment were observed. Subjects demonstrating high DBP reactivity required high doses of beta-blocker for resting DBP reduction, and these subjects showed the least change in mood at high doses. Similar patterns were found for the relationship of SBP reactivity and blood pressure and mood responsiveness to drug treatment, but these relationships were not statistically significant

  12. Get the Most Out of Home Blood Pressure Monitoring

    MedlinePlus

    ... Public-use blood pressure measurement: The kiosk quandary. Journal of the American Society of Hypertension. 2014;8:739. Padwal RS, et al. Comparison ... to daytime ambulatory blood pressure in hypertensive subjects. Journal of the American ... 2015;9:123. Blood pressure monitors: Validations, papers ...

  13. The use of ambulatory blood pressure monitoring to confirm a diagnosis of high blood pressure by primary-care physicians in Oregon.

    PubMed

    Carter, Brittany U; Kaylor, Mary Beth

    2016-04-01

    Hypertension is the most commonly diagnosed medical condition in the USA. Unfortunately, patients are misdiagnosed in primary care because of inaccurate office-based blood pressure measurements. Several US healthcare organizations currently recommend confirming an office-based hypertension diagnosis with ambulatory blood pressure monitoring to avoid overtreatment; however, its use for the purpose of confirming an office-based hypertension diagnosis is relatively unknown. This descriptive study surveyed 143 primary-care physicians in Oregon with regard to their current use of ambulatory blood pressure monitoring. Nineteen percent of the physicians reported that they would use ambulatory blood pressure monitoring to confirm an office-based hypertension diagnosis, although over half had never ordered it. The most frequent indication for ordering ambulatory blood pressure monitoring was to investigate suspected white-coat hypertension (37.3%). In addition, many of the practices did not own an ambulatory blood pressure monitoring device (79.7%) and, therefore, had to refer patients to other clinics or departments for testing. Many primary-care physicians will need to change their current clinical practice to align with the shift toward a confirmation process for office-based hypertension diagnoses to improve population health.

  14. Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality.

    PubMed

    Banegas, José R; Ruilope, Luis M; de la Sierra, Alejandro; Vinyoles, Ernest; Gorostidi, Manuel; de la Cruz, Juan J; Ruiz-Hurtado, Gema; Segura, Julián; Rodríguez-Artalejo, Fernando; Williams, Bryan

    2018-04-19

    Evidence for the influence of ambulatory blood pressure on prognosis derives mainly from population-based studies and a few relatively small clinical investigations. This study examined the associations of blood pressure measured in the clinic (clinic blood pressure) and 24-hour ambulatory blood pressure with all-cause and cardiovascular mortality in a large cohort of patients in primary care. We analyzed data from a registry-based, multicenter, national cohort that included 63,910 adults recruited from 2004 through 2014 in Spain. Clinic and 24-hour ambulatory blood-pressure data were examined in the following categories: sustained hypertension (elevated clinic and elevated 24-hour ambulatory blood pressure), "white-coat" hypertension (elevated clinic and normal 24-hour ambulatory blood pressure), masked hypertension (normal clinic and elevated 24-hour ambulatory blood pressure), and normotension (normal clinic and normal 24-hour ambulatory blood pressure). Analyses were conducted with Cox regression models, adjusted for clinic and 24-hour ambulatory blood pressures and for confounders. During a median follow-up of 4.7 years, 3808 patients died from any cause, and 1295 of these patients died from cardiovascular causes. In a model that included both 24-hour and clinic measurements, 24-hour systolic pressure was more strongly associated with all-cause mortality (hazard ratio, 1.58 per 1-SD increase in pressure; 95% confidence interval [CI], 1.56 to 1.60, after adjustment for clinic blood pressure) than the clinic systolic pressure (hazard ratio, 1.02; 95% CI, 1.00 to 1.04, after adjustment for 24-hour blood pressure). Corresponding hazard ratios per 1-SD increase in pressure were 1.55 (95% CI, 1.53 to 1.57, after adjustment for clinic and daytime blood pressures) for nighttime ambulatory systolic pressure and 1.54 (95% CI, 1.52 to 1.56, after adjustment for clinic and nighttime blood pressures) for daytime ambulatory systolic pressure. These relationships were

  15. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial.

    PubMed

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels

    2018-01-17

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Blood Pressure Control

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Engineering Development Lab., Inc.'s E-2000 Neck Baro Reflex System was developed for cardiovascular studies of astronauts. It is regularly used on Space Shuttle Missions, and a parallel version has been developed as a research tool to facilitate studies of blood pressure reflex controls in patients with congestive heart failure, diabetes, etc. An advanced version, the PPC-1000, was developed in 1991, and the technology has been refined substantially. The PPC provides an accurate means of generating pressure for a broad array of laboratory applications. An improved version, the E2010 Barosystem, is anticipated.

  17. Validation of the A&D UM-201 device for office blood pressure measurement according to the European Society of Hypertension International Protocol Revision 2010.

    PubMed

    Fania, Claudio; Albertini, Federica; Palatini, Paolo

    2017-08-01

    The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  18. Wearing an abdominal belt increases diastolic blood pressure.

    PubMed

    Rafacz, W; McGill, S M

    1996-09-01

    The purpose of this study was to determine the effect of wearing an abdominal belt on blood pressure (systolic and diastolic) and heart rate during a variety of tasks. The belt was typical of the elastic type with suspenders and Velcro tabs for cinching the belt snug. The tasks performed included sitting at rest, sitting with the torso inclined forward at 45 degrees, standing with the torso inclined forward at 45 degrees (with and without holding an 11-kg weight), a trunk axial rotation task, and squat lifting. Blood pressure was monitored noninvasively with a FINAPRES blood pressure monitor. Twenty healthy men performed each task with and without the abdominal belt. Although no significant increases in mean systolic blood pressure or heart rate were found, there was a significant increase in diastolic blood pressure in all conditions. All people considering wearing an abdominal belt should also consider the risks and liability associated with the additional cardiovascular load, particularly heart attack and stroke.

  19. Blood Pressure Measurement Guidelines for Physical Therapists

    PubMed Central

    Fick, Ann; Sadowsky, H. Steven

    2011-01-01

    Vital sign measurement and assessment are important components of the review of systems in a physical therapy examination for individuals with and without documented cardiopulmonary disease. The measurement of blood pressure gives the therapist information regarding the patient's baseline cardiovascular status, response to exercise/activity, and guides exercise prescription. Accurate measurement of blood pressure is critical for making appropriate clinical decisions especially if physical therapists wish to play an important role as primary health care providers. The purpose of this paper is to present recommended guidelines for blood pressure measurement by physical therapists and physical therapist assistants. PMID:21637392

  20. Blood pressure measurement guidelines for physical therapists.

    PubMed

    Frese, Ethel M; Fick, Ann; Sadowsky, H Steven

    2011-06-01

    Vital sign measurement and assessment are important components of the review of systems in a physical therapy examination for individuals with and without documented cardiopulmonary disease. The measurement of blood pressure gives the therapist information regarding the patient's baseline cardiovascular status, response to exercise/activity, and guides exercise prescription. Accurate measurement of blood pressure is critical for making appropriate clinical decisions especially if physical therapists wish to play an important role as primary health care providers. The purpose of this paper is to present recommended guidelines for blood pressure measurement by physical therapists and physical therapist assistants.

  1. [Current clinical aspects of ambulatory blood pressure monitoring].

    PubMed

    Sauza-Sosa, Julio César; Cuéllar-Álvarez, José; Villegas-Herrera, Karla Montserrat; Sierra-Galán, Lilia Mercedes

    2016-01-01

    Systemic arterial hypertension is the prevalentest disease worldwide that significantly increases cardiovascular risk. An early diagnosis together to achieve goals decreases the risk of complications significatly. Recently have been updated the diagnostic criteria for hypertension and the introduction of ambulatory blood pressure monitoring. The introduction into clinical practice of ambulatory blood pressure monitoring was to assist the diagnosis of «white coat hypertension» and «masked hypertension». Today has also shown that ambulatory blood pressure monitoring is better than the traditional method of recording blood pressure in the office, to the diagnosis and to adequate control and adjustment of drug treatment. Also there have been introduced important new concepts such as isloted nocturnal hypertension, morning blood pressure elevation altered and altered patterns of nocturnal dip in blood pressure; which have been associated with increased cardiovascular risk. Several studies have shown significant prognostic value in some stocks. There are still other concepts on which further study is needed to properly establish their introduction to clinical practice as hypertensive load variability, pulse pressure and arterial stiffness. In addition to setting values according to further clinical studies in populations such as elderly and children. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  2. Blood pressure in early autosomal dominant polycystic kidney disease.

    PubMed

    Schrier, Robert W; Abebe, Kaleab Z; Perrone, Ronald D; Torres, Vicente E; Braun, William E; Steinman, Theodore I; Winklhofer, Franz T; Brosnahan, Godela; Czarnecki, Peter G; Hogan, Marie C; Miskulin, Dana C; Rahbari-Oskoui, Frederic F; Grantham, Jared J; Harris, Peter C; Flessner, Michael F; Bae, Kyongtae T; Moore, Charity G; Chapman, Arlene B

    2014-12-11

    Hypertension is common in autosomal dominant polycystic kidney disease (ADPKD) and is associated with increased total kidney volume, activation of the renin-angiotensin-aldosterone system, and progression of kidney disease. In this double-blind, placebo-controlled trial, we randomly assigned 558 hypertensive participants with ADPKD (15 to 49 years of age, with an estimated glomerular filtration rate [GFR] >60 ml per minute per 1.73 m(2) of body-surface area) to either a standard blood-pressure target (120/70 to 130/80 mm Hg) or a low blood-pressure target (95/60 to 110/75 mm Hg) and to either an angiotensin-converting-enzyme inhibitor (lisinopril) plus an angiotensin-receptor blocker (telmisartan) or lisinopril plus placebo. The primary outcome was the annual percentage change in the total kidney volume. The annual percentage increase in total kidney volume was significantly lower in the low-blood-pressure group than in the standard-blood-pressure group (5.6% vs. 6.6%, P=0.006), without significant differences between the lisinopril-telmisartan group and the lisinopril-placebo group. The rate of change in estimated GFR was similar in the two medication groups, with a negative slope difference in the short term in the low-blood-pressure group as compared with the standard-blood-pressure group (P<0.001) and a marginally positive slope difference in the long term (P=0.05). The left-ventricular-mass index decreased more in the low-blood-pressure group than in the standard-blood-pressure group (-1.17 vs. -0.57 g per square meter per year, P<0.001); urinary albumin excretion was reduced by 3.77% with the low-pressure target and increased by 2.43% with the standard target (P<0.001). Dizziness and light-headedness were more common in the low-blood-pressure group than in the standard-blood-pressure group (80.7% vs. 69.4%, P=0.002). In early ADPKD, the combination of lisinopril and telmisartan did not significantly alter the rate of increase in total kidney volume. As

  3. A common humoral background of intraocular and arterial blood pressure dysregulation.

    PubMed

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  4. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    PubMed

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  5. Orthostatic blood pressure regulation predicts classroom effort in children.

    PubMed

    Carapetian, Stephanie; Siedlarz, Monika; Jackson, Sandra; Perlmuter, Lawrence C

    2008-04-01

    The increase in orthostatic systolic blood pressure associated with the shift in posture from lying to standing requires several compensatory mechanisms to ensure adequate cerebral perfusion. Decreased efficiency in the various mechanisms controlling orthostatic blood pressure regulation can result in dizziness, lightheadedness, and syncope. The degree of effectiveness of orthostatic systolic blood pressure regulation (OBPR) serves as a marker for a variety of problems including fatigue, depression, anxiety, reduced attention, impulsive behavior and reduced volition. In normal children, an insufficient increase in systolic blood pressure in response to upright posture is predictive of mild cognitive and affective problems. The present study examined orthostatic systolic blood pressure regulation in relation to yearlong teachers' evaluations of academic grades and effort in 7-11 year old children. Poorer systolic blood pressure regulation in response to orthostasis was associated with reduced levels of classroom effort, while academic grades were spared. Converging evidence from clinical as well as experimental studies suggests that the linkage between (OBPR) and effort may be partially mediated by sympathetic dysfunction, altered release of neurotransmitters, or reduced cerebral blood flow.

  6. A new model-free index of dynamic cerebral blood flow autoregulation.

    PubMed

    Chacón, Max; Jara, José Luis; Panerai, Ronney B

    2014-01-01

    The classic dynamic autoregulatory index (ARI), proposed by Aaslid and Tiecks, is one of the most widely used methods to assess the efficiency of dynamic cerebral autoregulation. Although this index is often used in clinical research and is also included in some commercial equipment, it exhibits considerable intra-subject variability, and has the tendency to produce false positive results in clinical applications. An alternative index of dynamic cerebral autoregulation is proposed, which overcomes most of the limitations of the classic method and also has the advantage of being model-free. This new index uses two parameters that are obtained directly from the response signal of the cerebral blood flow velocity to a transient decrease in arterial blood pressure provoked by the sudden release of bilateral thigh cuffs, and a third parameter measuring the difference in slope of this response and the change in arterial blood pressure achieved. With the values of these parameters, a corresponding classic autoregulatory index value could be calculated by using a linear regression model built from theoretical curves generated with the Aaslid-Tiecks model. In 16 healthy subjects who underwent repeated thigh-cuff manoeuvres, the model-free approach exhibited significantly lower intra-subject variability, as measured by the unbiased coefficient of variation, than the classic autoregulatory index (p = 0.032) and the Rate of Return (p<0.001), another measure of cerebral autoregulation used for this type of systemic pressure stimulus, from 39.23%±41.91% and 55.31%±31.27%, respectively, to 15.98%±7.75%.

  7. A New Model-Free Index of Dynamic Cerebral Blood Flow Autoregulation

    PubMed Central

    Chacón, Max; Jara, José Luis; Panerai, Ronney B.

    2014-01-01

    The classic dynamic autoregulatory index (ARI), proposed by Aaslid and Tiecks, is one of the most widely used methods to assess the efficiency of dynamic cerebral autoregulation. Although this index is often used in clinical research and is also included in some commercial equipment, it exhibits considerable intra-subject variability, and has the tendency to produce false positive results in clinical applications. An alternative index of dynamic cerebral autoregulation is proposed, which overcomes most of the limitations of the classic method and also has the advantage of being model-free. This new index uses two parameters that are obtained directly from the response signal of the cerebral blood flow velocity to a transient decrease in arterial blood pressure provoked by the sudden release of bilateral thigh cuffs, and a third parameter measuring the difference in slope of this response and the change in arterial blood pressure achieved. With the values of these parameters, a corresponding classic autoregulatory index value could be calculated by using a linear regression model built from theoretical curves generated with the Aaslid-Tiecks model. In 16 healthy subjects who underwent repeated thigh-cuff manoeuvres, the model-free approach exhibited significantly lower intra-subject variability, as measured by the unbiased coefficient of variation, than the classic autoregulatory index (p = 0.032) and the Rate of Return (p<0.001), another measure of cerebral autoregulation used for this type of systemic pressure stimulus, from 39.23%±41.91% and 55.31%±31.27%, respectively, to 15.98%±7.75%. PMID:25313519

  8. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm...

  9. 21 CFR 870.1110 - Blood pressure computer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1110 Blood pressure...

  10. [Blood pressure variability: clinical interest or simple curiosity?].

    PubMed

    Ciaroni, Stefano

    2007-03-14

    Blood pressure variability is a physiological phenomenon influenced by many internal and external factors. This variability could be also influenced by pathological conditions such as arterial hypertension. Two forms must be mainly distinguished: the blood pressure variability at long and short-term. The latter could only be studied by continuous recordings. In this article will be analysed the interest of measuring blood pressure variability, its cardiovascular prognosis and the therapeutic tools when it is increased.

  11. Blood pressure as a therapeutic target in stroke.

    PubMed

    Armario, Pedro; de la Sierra, Alejandro

    2009-01-01

    Stroke, as a clinical manifestation of the cardiovascular diseases, is one of the leading causes of death and disability in both developed and developing countries. Hypertension is by far, the most important risk factor for stroke. Epidemiological data indicate that the risk of stroke increases with both systolic and diastolic blood pressure elevation, from levels of 115/75 mmHg. It is also evident that most adults worldwide have values above these limits, thus emphasizing the importance of blood pressure as a risk factor for stroke. Clinical trials of antihypertensive treatment, both in studies that have compared active drugs against placebo or in those comparing different types of drugs have clearly demonstrated a protective effect of blood pressure reduction in the prevention of stroke. The degree of protection is directly related to blood pressure reduction and, the lower the level, the better the prognosis. Although data on secondary stroke prevention are scarcer, studies also seem to indicate that lowering blood pressure with antihypertensive treatment protects against stroke recurrence. At the present moment there is still uncertainty on 2 different aspects regarding the relationship between antihypertensive treatment and stroke. First, the blood pressure management during acute stroke has not adequately investigated in clinical trials. Second, the possibility of a protective role of specific types of antihypertensive drugs beyond blood pressure reduction is a matter of debate. Independently of these unresolved issues, prevention of hypertension development by lifestyle changes and adequate treatment and control to the hypertensive population will be a very effective measure in reducing stroke incidence, stroke recurrence, and stroke mortality.

  12. Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time

    NASA Astrophysics Data System (ADS)

    Martin, Stephanie L.-O.; Carek, Andrew M.; Kim, Chang-Sei; Ashouri, Hazar; Inan, Omer T.; Hahn, Jin-Oh; Mukkamala, Ramakrishna

    2016-12-01

    Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms - and thus PTT through larger, more elastic arteries - in terms of its ability to improve tracking of BP in individual subjects. We measured “scale PTT”, conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of -0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of -0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.

  13. Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time.

    PubMed

    Martin, Stephanie L-O; Carek, Andrew M; Kim, Chang-Sei; Ashouri, Hazar; Inan, Omer T; Hahn, Jin-Oh; Mukkamala, Ramakrishna

    2016-12-15

    Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms - and thus PTT through larger, more elastic arteries - in terms of its ability to improve tracking of BP in individual subjects. We measured "scale PTT", conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of -0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of -0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.

  14. Ultrasound determination of rotator cuff tear repairability

    PubMed Central

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  15. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    PubMed

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  16. Lack of association between systolic blood pressure and blood viscosity in normotensive healthy subjects.

    PubMed

    Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino

    2012-01-01

    A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.

  17. Associations between bacterial infections and blood pressure in pregnancy.

    PubMed

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  18. 21 CFR 870.1110 - Blood pressure computer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  19. 21 CFR 870.1110 - Blood pressure computer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  20. 21 CFR 870.1110 - Blood pressure computer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  1. 21 CFR 870.1110 - Blood pressure computer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  2. Dark chocolate for children's blood pressure: randomised trial.

    PubMed

    Chan, Eunice K; Quach, Jon; Mensah, Fiona K; Sung, Valerie; Cheung, Michael; Wake, Melissa

    2012-07-01

    Higher adult blood pressure, even without hypertension, predicts cardiovascular outcomes, and is predicted by childhood blood pressure. Regular dark chocolate intake lowers blood pressure in adults, but effects in children are unknown. To examine the feasibility of school-based provision of dark chocolate and its short-term efficacy in reducing mean group blood pressure. 194 children (aged 10-12 years) were randomised by class to intervention (7 g dark chocolate daily for 7 weeks, n=124) or control (n=70) groups; 98% and 93% provided baseline and follow-up measurements, respectively. Intervention and control students had similar systolic (mean difference 1.7 mm Hg, 95% CI -0.6 to 4.1) and diastolic (-1.2 mm Hg, 95% CI -3.6 to 1.3) blood pressure, anthropometry and well-being at outcome. Results show that providing dark chocolate is feasible and acceptable in the school setting. For a definitive trial, the authors recommend a larger sample, endovascular function measures, and consideration of higher antioxidant 'dose' by virtue of duration and/or content.

  3. A Ubiquitous Blood Pressure Sensor Worn at the Ear

    NASA Astrophysics Data System (ADS)

    Koizumi, Hiroshi; Shimada, Junichi; Uenishi, Yuji; Tochikubo, Osamu

    2009-12-01

    Blood pressure (BP) measurement and BP control are important for the prevention of lifestyle diseases, especially hypertension, which can lead to more serious conditions, such as cardiac infarction and cerebral apoplexy. The purpose of our study is to develop a ubiquitous blood pressure sensor that is more comfortable and less disruptive of users' daily activities than conventional blood pressure sensors. Our developed sensor is worn at an ear orifice and measures blood pressure at the tragus. This paper describes the concept, configuration, and the optical and electronic details of the developed ear-worn blood pressure sensor and presents preliminary evaluation results. The developed sensor causes almost no discomfort and produces signals whose quality is high enough for detecting BP at an ear, making it suitable for ubiquitous usage.

  4. Allergic rhinitis and arterial blood pressure: a population-based study.

    PubMed

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  5. The optimum tension for bridging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study.

    PubMed

    Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han

    2015-09-01

    Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase

  6. [Development of a continuous blood pressure monitoring and recording system].

    PubMed

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  7. 21 CFR 882.5275 - Nerve cuff.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...

  8. 21 CFR 882.5275 - Nerve cuff.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...

  9. High blood pressure in acute ischemic stroke and clinical outcome

    PubMed Central

    Manabe, Yasuhiro; Kono, Syoichiro; Tanaka, Tomotaka; Narai, Hisashi; Omori, Nobuhiko

    2009-01-01

    This study aimed to evaluate the prognostic value of acute phase blood pressure in patients with acute ischemic stroke by determining whether or not it contributes to clinical outcome. We studied 515 consecutive patients admitted within the first 48 hours after the onset of ischemic strokes, employing systolic and diastolic blood pressure measurements recorded within 36 hours after admission. High blood pressure was defined when the mean of at least 2 blood pressure measurements was ≥200 mmHg systolic and/or ≥110 mmHg diastolic at 6 to 24 hours after admission or ≥180 mmHg systolic and/or ≥105 mmHg diastolic at 24 to 36 hours after admission. The high blood pressure group was found to include 16% of the patients. Age, sex, diabetes mellitus, hypercholesterolemia, atrial fibrillation, ischemic heart disease, stroke history, carotid artery stenosis, leukoaraiosis, NIH Stroke Scale (NIHSS) on admission and mortality were not significantly correlated with either the high blood pressure or non-high blood pressure group. High blood pressure on admission was significantly associated with a past history of hypertension, kidney disease, the modified Rankin Scale (mRS) on discharge and the length of stay. On logistic regression analysis, with no previous history of hypertension, diabetes mellitus, atrial fibrillation, and kidney disease were independent risk factors associated with the presence of high blood pressure [odds ratio (OR), 1.85 (95% confidence interval (CI): 1.06–3.22), 1.89 (95% CI: 1.11–3.22), and 3.31 (95% CI: 1.36–8.04), respectively]. Multi-organ injury may be presented in acute stroke patients with high blood pressure. Patients with high blood pressure had a poor functional outcome after acute ischemic stroke. PMID:21577346

  10. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    PubMed

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these

  11. Job strain, blood pressure and response to uncontrollable stress.

    PubMed

    Steptoe, A; Cropley, M; Joekes, K

    1999-02-01

    The association between cardiovascular disease risk and job strain (high-demand, low-control work) may be mediated by heightened physiological stress responsivity. We hypothesized that high levels of job strain lead to increased cardiovascular responses to uncontrollable but not controllable stressors. Associations between job strain and blood pressure reductions after the working day (unwinding) were also assessed. Assessment of cardiovascular responses to standardized behavioral tasks, and ambulatory monitoring of blood pressure and heart rate during a working day and evening. We studied 162 school teachers (60 men, 102 women) selected from a larger survey as experiencing high or low job strain. Blood pressure, heart rate and electrodermal responses to an externally paced (uncontrollable) task and a self-paced (controllable) task were assessed. Blood pressure was monitored using ambulatory apparatus from 0900 to 2230 h on a working day. The groups of subjects with high and low job strain did not differ in demographic factors, body mass or resting cardiovascular activity. Blood pressure reactions to the uncontrollable task were greater in high than low job-strain groups, but responses to the controllable task were not significantly different between groups. Systolic and diastolic blood pressure did not differ between groups over the working day, but decreased to a greater extent in the evening in subjects with low job strain. Job strain is associated with a heightened blood pressure response to uncontrollable but not controllable tasks. The failure of subjects with high job strain to show reduced blood pressure in the evening may be a manifestation of chronic allostatic load.

  12. High blood pressure - what to ask your doctor

    MedlinePlus

    What to ask your doctor about high blood pressure; Hypertension - what to ask your doctor ... problems? What medicines am I taking to treat high blood pressure? Do they have any side effects? What should ...

  13. [Evaluation of antihypertensive therapy by ambulatory blood pressure monitoring and establishment of the level of antihypertensive goal on the circadian rhythm of blood pressure].

    PubMed

    Fujioka, T; Tamaki, S; Fudo, T; Nakae, I; Sugawara, A; Kambara, H

    1990-01-01

    We have developed a new method for the evaluation of antihypertensive therapy on the circadian rhythm of blood pressure and attempted to determine the indications for antihypertensive therapy and the level of antihypertensive goal. Blood pressures were measured for 24 hours by the use of ambulatory blood pressure monitoring using 630 (ABPM-630) in 50 normotensives, 50 untreated hypertensives and 50 hypertensives undertreatment with various antihypertensive drugs (110 males and 40 females, with a mean age of 53.4 +/- 13.3 yrs). Blood pressure profiles were prepared for determination of the hyperbaric and hypobaric indexes. According to the WHO's definitions for blood pressure, the hyperbaric index was defined as the area above 140 mmHg in systolic blood pressure or 90 mmHg in diastolic blood pressure, and the hypobaric index, as the area below 100 mmHg or 60 mmHg, respectively. The criteria of the hypobaric index was obtained from the mean basal blood pressure (the lowest blood pressure during sleep) of the 50 normotensives. The mean hyperbaric index of the 50 normotensives was 20.4 +/- 40.2/5.5 +/- 15.3 (systole/diastole) mmHg.hour/day and the mean hypobaric index, 12.2 +/- 22.5/9.0 +/- 24.0 mmHg.hour/day. The 50 untreated hypertensives showed a mean hyperbaric index of 281.8 +/- 197.0/156.0 +/- 126.1 mmHg.hour/day and a mean hypobaric index of 0.1 +/- 0.6/0.3 +/- 1.5 mmHg.hour/day. Comparison of the indexes before and after treatment with various antihypertensives showed that a decrease in the hyperbaric index without an increase in the hypobaric index was the most optimal reduction of blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Evaluation of the effects of dorsal versus lateral recumbency on the cardiopulmonary system during anesthesia with isoflurane in red-tailed hawks (Buteo jamaicensis).

    PubMed

    Hawkins, Michelle G; Malka, Shachar; Pascoe, Peter J; Solano, Adrian M; Kass, Philip H; Ohmura, Hajime; Jones, James H

    2013-01-01

    To evaluate the effects of dorsal versus lateral recumbency on the cardiopulmonary system during isoflurane anesthesia in red-tailed hawks (Buteo jamaicensis). 6 adult 1.1- to 1.6-kg red-tailed hawks. A randomized, crossover study was used to evaluate changes in respiratory rate, tidal volume, minute ventilation, heart rate, mean arterial and indirect blood pressures, and end-tidal Pco(2) measured every 5 minutes plus Paco(2) and Pao(2) and arterial pH measured every 15 minutes throughout a 75-minute study period. Respiratory rate was higher, tidal volume lower, and minute ventilation not different in lateral versus dorsal recumbency. Position did not affect heart rate, mean arterial blood pressure, or indirect blood pressure, although heart rate decreased during the anesthetic period. Birds hypoventilated in both positions and Paco(2) differed with time and position × time interaction. The Petco(2) position × time interaction was significant and Petco(2) was a mean of 7 Torr higher than Paco(2). The Paco(2) in dorsal recumbency was a mean of 32 Torr higher than in lateral recumbency. Birds in both positions developed respiratory acidosis. Differences in tidal volume with similar minute ventilation suggested red-tailed hawks in dorsal recumbency might have lower dead space ventilation. Despite similar minute ventilation in both positions, birds in dorsal recumbency hypoventilated more yet maintained higher Pao(2), suggesting parabronchial ventilatory or pulmonary blood flow distribution changes with position. The results refute the hypothesis that dorsal recumbency compromises ventilation and O(2) transport more than lateral recumbency in red-tailed hawks.

  15. Blood pressure control for diabetic retinopathy

    PubMed Central

    Do, Diana V; Wang, Xue; Vedula, Satyanarayana S; Marrone, Michael; Sleilati, Gina; Hawkins, Barbara S; Frank, Robert N

    2015-01-01

    Background Diabetic retinopathy is a common complication of diabetes and a leading cause of visual impairment and blindness. Research has established the importance of blood glucose control to prevent development and progression of the ocular complications of diabetes. Simultaneous blood pressure control has been advocated for the same purpose, but findings reported from individual studies have supported varying conclusions regarding the ocular benefit of interventions on blood pressure. Objectives The primary aim of this review was to summarize the existing evidence regarding the effect of interventions to control or reduce blood pressure levels among diabetics on incidence and progression of diabetic retinopathy, preservation of visual acuity, adverse events, quality of life, and costs. A secondary aim was to compare classes of anti-hypertensive medications with respect to the same outcomes. Search methods We searched a number of electronic databases including CENTRAL as well as ongoing trial registries. We last searched the electronic databases on 25 April 2014. We also reviewed reference lists of review articles and trial reports selected for inclusion. In addition, we contacted investigators of trials with potentially pertinent data. Selection criteria We included in this review randomized controlled trials (RCTs) in which either type 1 or type 2 diabetic participants, with or without hypertension, were assigned randomly to intense versus less intense blood pressure control, to blood pressure control versus usual care or no intervention on blood pressure, or to different classes of anti-hypertensive agents versus placebo. Data collection and analysis Pairs of review authors independently reviewed titles and abstracts from electronic and manual searches and the full text of any document that appeared to be relevant. We assessed included trials independently for risk of bias with respect to outcomes reported in this review. We extracted data regarding trial

  16. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    PubMed

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  17. Multicentre randomised controlled trial to investigate the usefulness of continuous pneumatic regulation of tracheal cuff pressure for reducing ventilator-associated pneumonia in mechanically ventilated severe trauma patients: the AGATE study protocol

    PubMed Central

    Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier

    2017-01-01

    Introduction Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. Methods and analysis This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. Ethics and dissemination This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer

  18. Multicentre randomised controlled trial to investigate the usefulness of continuous pneumatic regulation of tracheal cuff pressure for reducing ventilator-associated pneumonia in mechanically ventilated severe trauma patients: the AGATE study protocol.

    PubMed

    Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier

    2017-08-07

    Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Clinical Trials NCT02534974. © Article author(s) (or

  19. Life-course blood pressure in relation to brain volumes

    PubMed Central

    Power, Melinda C.; Schneider, Andrea L. C.; Wruck, Lisa; Griswold, Michael; Coker, Laura H.; Alonso, Alvaro; Jack, Clifford R.; Knopman, David; Mosley, Thomas H.; Gottesman, Rebecca F

    2016-01-01

    INTRODUCTION The impact of blood pressure on brain volumes may be time- or pattern-dependent. METHODS In 1678 participants from the Atherosclerosis Risk in Communities Neurocognitive Study, we quantified the association between measures and patterns of blood pressure over three time points (~24 or ~15 years prior and concurrent with neuroimaging) with late life brain volumes. RESULTS Higher diastolic blood pressure ~24 years prior, higher systolic and pulse pressure ~15 years prior, and consistently elevated or rising systolic blood pressure from ~15 years prior to concurrent with neuroimaging, but not blood pressures measured concurrent with neuroimaging, were associated with smaller volumes. The pattern of hypertension ~15 years prior and hypotension concurrent with neuroimaging was associated with smaller volumes in regions preferentially affected by Alzheimer’s disease (e.g., hippocampus: −0.27 standard units, 95%CI:−0.51,−0.03). DISCUSSION Hypertension 15 to 24 years prior is relevant to current brain volumes. Hypertension followed by hypotension appears particularly detrimental. PMID:27139841

  20. Changes You Can Make to Manage High Blood Pressure

    MedlinePlus

    ... about Bayer Consumer Health. HBP Resources Risk Calculator Animation Library Track Your Blood Pressure: Print (PDF) | Online ... Pressure Tracker Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  1. Blood Pressure Medications: Can They Raise My Triglycerides?

    MedlinePlus

    ... medications: Can they raise my triglycerides? Can some blood pressure medications cause an increase in triglycerides? Answers from Sheldon G. Sheps, M.D. Yes, some blood pressure medications can affect triglyceride and cholesterol levels. Hydrochlorothiazide ...

  2. On cuff imbalance and tripolar ENG amplifier configurations.

    PubMed

    Triantis, Iasonas F; Demosthenous, Andreas; Donaldson, Nick

    2005-02-01

    Electroneurogram (ENG) recording techniques benefit from the use of tripolar cuffs because they assist in reducing interference from sources outside the cuff. However, in practice the performance of ENG amplifier configurations, such as the quasi-tripole and the true-tripole, has been widely reported to be degraded due to the departure of the tripolar cuff from ideal behavior. This paper establishes the presence of cuff imbalance and investigates its relationship to cuff asymmetry, cuff end-effects and interference source proximity. The paper also presents a comparison of the aforementioned amplifier configurations with a new alternative, termed the adaptive-tripole, developed to automatically compensate for cuff imbalance. The output signal-to-interference ratio of the three amplifier configurations were compared in vivo for two interference signals (stimulus artifact and M-wave) superimposed on compound action potentials. The experiments showed (for the first time) that the two interference signals result in different cuff imbalance values. Nevertheless, even with two distinct cuff imbalances present, the adaptive-tripole performed better than the other two systems in 61.9% of the trials.

  3. [Blood pressure targets : The lower the better does not suit all].

    PubMed

    Hoffmann, U

    2018-04-01

    The systolic blood pressure intervention trial (SPRINT) published in 2015 has opened up new discussions on whether a lower blood pressure target as recommended by the current guidelines would be better for some patient groups. To review patient groups in which lower blood pressure targets would not be better. The results of SPRINT, its post-hoc and subgroup analyses, other studies and newer studies, as well as metaanalyses on the topic of blood pressure targets are reviewed and discussed. Studies with patients excluded from the SPRINT study were also analysed. The current international guidelines and recommendations of the Deutsche Hochdruckliga e. V. DHL® are included. Blood pressure monitoring methods differed considerably in the previously published studies. The low blood pressure value in SPRINT was mainly achieved due to the unusual method of blood pressure monitoring used and, as such, cannot be compared with blood pressure values in other studies. Based on current evidence, "the lower the better" should not be recommended in the following patient groups: older patients, in particular infirm older patients, patients with diabetes, patients without coronary heart disease or with low cardiovascular risk. When determining a blood pressure target, the method of blood pressure monitoring should be defined. A lower blood pressure target has been shown to be better in some well defined patient groups. However, adverse events due to antihypertensive medications should always be taken into account. Given the multiple exclusion criteria in trials and the results of many studies, "new" lower blood pressure targets could not be recommended in a large population of patients.

  4. Social support, stress, and blood pressure in black adults.

    PubMed

    Strogatz, D S; Croft, J B; James, S A; Keenan, N L; Browning, S R; Garrett, J M; Curtis, A B

    1997-09-01

    Psychosocial factors arising from socioeconomic disadvantage and discrimination may contribute to the excess risk of elevated blood pressure in African-Americans. The purpose of this study was to assess the association of social support and stress with blood pressure in a community-based sample of 25-to 50-year-old black adults in Pitt County, NC. A stratified random sample of dwellings was selected in 1988, and 1,784 black adults (80% of those eligible) were interviewed. Analyses were sex specific and adjusted for age, obesity, and waist/hip ratio. In separate analyses of emotional support, instrumental support, and stress with blood pressure, all associations were in the predicted direction (inverse for support, direct for stress) but were stronger for systolic than for diastolic blood pressure. Differences in systolic blood pressure associated with low support or high stress ranged from 5.2 to 3.6 mmHg in women and 3.5 to 2.5 mmHg in men. In simultaneous regression analyses of support and stress, each of the separate effects was reduced for women, but a sizable aggregate effect of low support and high stress remained [+7.2 mmHg (95% confidence limits = +1.3, +13.1) for systolic blood pressure and +4.0 mmHg (95% confidence limits = +0.1, +7.9) for diastolic blood pressure.

  5. HealthLines: Control Blood Pressure, Protect Your Kidneys

    MedlinePlus

    ... Home Current Issue Past Issues Health Lines Control Blood Pressure, Protect Your Kidneys Past Issues / Fall 2008 Table ... on. By Shana Potash, Staff Writer, NLM High blood pressure is a leading cause of chronic kidney disease ( ...

  6. Risk Associated with Pulse Pressure on Out-of-Office Blood Pressure Measurement

    PubMed Central

    Gu, Yu-Mei; Aparicio, Lucas S.; Liu, Yan-Ping; Asayama, Kei; Hansen, Tine W.; Niiranen, Teemu J.; Boggia, José; Thijs, Lutgarde; Staessen, Jan A.

    2014-01-01

    Background Longitudinal studies have demonstrated that the risk of cardiovascular disease increases with pulse pressure (PP). However, PP remains an elusive cardiovascular risk factor with findings being inconsistent between studies. The 2013 ESH/ESC guideline proposed that PP is useful in stratification and suggested a threshold of 60 mm Hg, which is 10 mm Hg higher compared to that in the 2007 guideline; however, no justification for this increase was provided. Methodology Published thresholds of PP are based on office blood pressure measurement and often on arbitrary categorical analyses. In the International Database on Ambulatory blood pressure in relation to Cardiovascular Outcomes (IDACO) and the International Database on HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO), we determined outcome-driven thresholds for PP based on ambulatory or home blood pressure measurement, respectively. Results The main findings were that for people aged <60 years, PP did not refine risk stratification, whereas in older people the thresholds were 64 and 76 mm Hg for the ambulatory and home PP, respectively. However, PP provided little added predictive value over and beyond classical risk factors. PMID:26587443

  7. Increased nocturnal blood pressure in enuretic children with polyuria.

    PubMed

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p <0.05). Furthermore, a positive correlation was seen between nocturnal urine output and nocturnal mean arterial pressure (r = 0.32, p <0.001). Nocturnal urine output was significantly higher during wet nights than dry nights (p <0.001). However, no significant difference was found in mean arterial pressure between wet and dry nights. Nocturnal mean arterial pressure was significantly higher in children with enuresis with polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  8. Socioeconomic disadvantage and change in blood pressure associated with aging.

    PubMed

    Diez Roux, Ana V; Chambless, Lloyd; Merkin, Sharon Stein; Arnett, Donna; Eigenbrodt, Marsha; Nieto, F Javier; Szklo, Moyses; Sorlie, Paul

    2002-08-06

    Few studies have examined how the longitudinal change in blood pressure associated with aging differs across social groups within industrialized countries. Data from the Atherosclerosis Risk In Communities Study were used to investigate differences in the incidence of hypertension and in aging-related changes in blood pressure by neighborhood and individual socioeconomic factors over a 9-year follow-up. Disadvantage in multiple socioeconomic dimensions was associated with the greatest risk of developing hypertension (age- and sex-adjusted hazard ratio [HR] and 95% CI: HR 1.95, 95% CI 1.38 to 2.75 in whites and HR 1.43, 95% CI 0.96 to 2.13 in blacks). Aging-related increases in systolic blood pressure were inversely associated with socioeconomic position in whites (mean [SEM] 5-year increase in systolic blood pressure 7 [0.7] mm Hg in the most disadvantaged category and 5.4 [0.4] mm Hg in the most advantaged category). In whites, low socioeconomic position was also associated with more rapid declines in diastolic blood pressure after 50 years of age. Socioeconomic differences in hypertension incidence and changes in systolic blood pressure were reduced after adjustment for baseline blood pressure. The change in blood pressure associated with aging varies by social groups within the United States.

  9. Blood pressure in firefighters, police officers, and other emergency responders.

    PubMed

    Kales, Stefanos N; Tsismenakis, Antonios J; Zhang, Chunbai; Soteriades, Elpidoforos S

    2009-01-01

    Elevated blood pressure is a major risk factor for cardiovascular morbidity and mortality. Increased risk begins in the prehypertensive range and increases further with higher pressures. The strenuous duties of emergency responders (firefighters, police officers, and emergency medical services (EMS) personnel) can interact with their personal risk profiles, including elevated blood pressure, to precipitate acute cardiovascular events. Approximately three-quarters of emergency responders have prehypertension or hypertension, a proportion which is expected to increase, based on the obesity epidemic. Elevated blood pressure is also inadequately controlled in these professionals and strongly linked to cardiovascular disease morbidity and mortality. Notably, the majority of incident cardiovascular disease events occur in responders who are initially prehypertensive or only mildly hypertensive and whose average premorbid blood pressures are in the range in which many physicians would hesitate to prescribe medications (140-146/88-92). Laws mandating public benefits for emergency responders with cardiovascular disease provide an additional rationale for aggressively controlling their blood pressure. This review provides a background on emergency responders, summarizes occupational risk factors for hypertension and the metabolic syndrome, their prevalence of elevated blood pressure, and evidence linking hypertension with adverse outcomes in these professions. Next, discrepancies between relatively outdated medical standards for emergency responders and current, evidence-based guidelines for blood pressure management in the general public are highlighted. Finally, a workplace-oriented approach for blood pressure control among emergency responders is proposed, based on the seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.

  10. Does chocolate reduce blood pressure? A meta-analysis.

    PubMed

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P < 0.05. Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment

  11. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    PubMed

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (p<0.001) at different inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  12. Is glycine effective against elevated blood pressure?

    PubMed

    El Hafidi, Mohammed; Pérez, Israel; Baños, Guadalupe

    2006-01-01

    Glycine, a non-essential amino acid, has been found to protect against oxidative stress in several pathological situations, and it is required for the biosynthesis of structural proteins such as elastin. As hypertension is a disease in which free radicals and large vessel elasticity are involved, this article will examine the possible mechanisms by which glycine may protect against high blood pressure. The addition of glycine to the diet reduces high blood pressure in a rat model of the metabolic syndrome. Also, glycine supplemented to the low protein diet of rat dams during pregnancy has a beneficial effect on blood pressure in their offspring. The mechanism by which glycine decreases high blood pressure can be attributed to its participation in the reduction of the generation of free radicals, increasing the availability of nitric oxide. In addition, as glycine is required for a number of critical metabolic pathways, such as the synthesis of the structural proteins collagen and elastin, the perturbation of these leads to impaired elastin formation in the aorta. This involves changes in the aorta's elastic properties, which would contribute to the development of hypertension. The use of glycine to lower high blood pressure could have a significant clinical impact in patients with the metabolic syndrome and with limited resources. On the other hand, more studies are needed to explore the beneficial effect of glycine in other models of hypertension and to investigate possible side-effects of treatment with glycine.

  13. Ethnic Differences in Physical Fitness, Blood Pressure and Blood Chemistry in Women (AGES 20-63)

    NASA Technical Reports Server (NTRS)

    Ayers, G. W.; Wier, L. T.; Jackson, A. S.; Stuteville, J. E.; Keptra, Sean (Technical Monitor)

    1999-01-01

    This study examined the role of ethnicity on the aerobic fitness, blood pressure, and selected blood chemistry values of women. One hundred twenty-four females (mean age 41.37 +/- 9.0) were medically Examined at the NASA/Johnson Space Center occupational health clinic. Ethnic groups consisted of 23 Black (B), 18 Hispanic (H) and 83 Non-minority (NM). Each woman had a maximum Bruce treadmill stress test (RER greater than or = 1.1) and a negative ECG. Indirect calorimetry, skinfolds, self-report physical activity (NASA activity scale), seated blood pressure, and blood chemistry panel determined VO2max, percent fat, level of physical activity, blood pressure and blood chemistry values. ANOVA revealed that the groups did not differ (p greater than 0.05) in age, VO2 max, weight, percent fat, level of physical activity, total cholesterol, or HDL-C. However, significant differences (p greater than 0.05) were noted in BMI, diastolic blood pressure, and blood chemistries. BMI was 3.17 higher in H than in NM; resting diastolic pressures were 5.69 and 8.05 mmHg. lower in NM and H than in B; triglycerides were 48.07 and 37.21 mg/dl higher in H than in B and NM; hemoglobin was .814 gm/dl higher in NM than B; fasting blood sugar was 15.41 mg/dl higher in H than NM; The results of this study showed that ethnic groups differed in blood pressure and blood chemistry values but not aerobic fitness or physical activity. There was an ethnic difference in BMI but not percent fat.

  14. Socioeconomic Status Modifies the Seasonal Effect on Blood Pressure

    PubMed Central

    Cois, Annibale; Ehrlich, Rodney

    2015-01-01

    Abstract Seasonal variations in blood pressure have been consistently reported. However, uncertainty remains about the size of the seasonal effect in different regions, and about factors that explain the differences observed across and within populations. Using data from a national panel study, we investigated seasonal variations in blood pressure in the South African adult population, and whether these variations differed across socioeconomic strata. We estimated age-specific seasonal effects on blood pressure using a multilevel structural equation model, with repeated measurements nested within subjects. Effect modification by socioeconomic status was assessed by repeating the analyses in the subpopulations defined by levels of education, household income per capita, and type of housing. In men and women, season had a statistically significant effect on blood pressure, with higher levels in winter and lower levels in summer. For systolic blood pressure, the magnitude of the seasonal effect was 4.25/4.21 mmHg (women/men) and was higher in the older age groups. For diastolic blood pressure, the effect size was 4.00/4.01 mmHg, with no evident age trend. Seasonal effects were higher among subjects in the lowest socioeconomic classes than in the highest, with differences between 2.4 and 7.7 mmHg, depending on gender, whether systolic or diastolic blood pressure, and socioeconomic status indicator. In the South African adult population, blood pressure shows seasonal variation modified by age and socioeconomic status. These variations have epidemiological, clinical, and public health implications, including the prospect of population level intervention to reduce elevated risk of cold weather cardiovascular morbidity. PMID:26334893

  15. The Role of Central Blood Pressure Monitoring in the Management of Hypertension.

    PubMed

    Ochoa, Adrian; Patarroyo-Aponte, Gabriel; Rahman, Mahboob

    2018-04-19

    Central blood pressure is a novel predictor of cardiovascular risk that can be measured in the clinical setting using currently available technology. This paper will review current available methods of central blood pressure monitoring as well as its impact in cardiac and renal disease. Both aortic and carotid systolic blood pressure are independently associated with cardiovascular mortality and serious cardiac events. Furthermore, studies show that systolic aortic blood pressure has been shown to be superior predictor of cardiovascular as compared to brachial blood pressure. Inhibitors of the renin angiotensin axis may have a beneficial effect on central blood pressure; however, long term studies evaluating the impact of lowering central blood pressure on clinical outcomes are lacking. Central blood pressure is a good predictor of cardiovascular risk. As more studies emerge demonstrating the value of central blood pressure as a therapeutic target, it is possible that targeting central blood pressure may become an important part of the armamentarium to lower cardiovascular risk.

  16. Blood pressure and pain sensitivity in children and adolescents.

    PubMed

    Drouin, Sammantha; McGrath, Jennifer J

    2013-06-01

    Elevated blood pressure is associated with diminished pain sensitivity. While this finding is well established in adults, it is less clear when the relation between blood pressure and pain sensitivity emerges across the life course. Evidence suggests this phenomenon may exist during childhood. Children (N = 309; 56% boys) aged 10-15 years and their parents participated. Blood pressure readings were taken during a resting baseline. Maximum pain intensity was rated using a visual analogue scale (rated 0-10) in response to a finger prick pain induction. Parent-measured resting blood pressure was inversely associated with boys' pain ratings only. Cross-sectionally, lower pain ratings were related to higher SBP, univariately. Longitudinally, pain ratings predicted higher DBP, even after controlling for covariates. Determining when and how the relation between blood pressure and pain sensitivity emerges may elucidate the pathophysiology of hypertension. Copyright © 2013 Society for Psychophysiological Research.

  17. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garner, Rochelle E., E-mail: rochelle.garner@canad

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models weremore » used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood

  18. Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2

    NASA Technical Reports Server (NTRS)

    Mark, R. G.

    1975-01-01

    The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.

  19. Significant interarm blood pressure difference predicts cardiovascular risk in hypertensive patients: CoCoNet study.

    PubMed

    Kim, Su-A; Kim, Jang Young; Park, Jeong Bae

    2016-06-01

    There has been a rising interest in interarm blood pressure difference (IAD), due to its relationship with peripheral arterial disease and its possible relationship with cardiovascular disease. This study aimed to characterize hypertensive patients with a significant IAD in relation to cardiovascular risk. A total of 3699 patients (mean age, 61 ± 11 years) were prospectively enrolled in the study. Blood pressure (BP) was measured simultaneously in both arms 3 times using an automated cuff-oscillometric device. IAD was defined as the absolute difference in averaged BPs between the left and right arm, and an IAD ≥ 10 mm Hg was considered to be significant. The Framingham risk score was used to calculate the 10-year cardiovascular risk. The mean systolic IAD (sIAD) was 4.3 ± 4.1 mm Hg, and 285 (7.7%) patients showed significant sIAD. Patients with significant sIAD showed larger body mass index (P < 0.001), greater systolic BP (P = 0.050), more coronary artery disease (relative risk = 1.356, P = 0.034), and more cerebrovascular disease (relative risk = 1.521, P = 0.072). The mean 10-year cardiovascular risk was 9.3 ± 7.7%. By multiple regression, sIAD was significantly but weakly correlated with the 10-year cardiovascular risk (β = 0.135, P = 0.008). Patients with significant sIAD showed a higher prevalence of coronary artery disease, as well as an increase in 10-year cardiovascular risk. Therefore, accurate measurements of sIAD may serve as a simple and cost-effective tool for predicting cardiovascular risk in clinical settings.

  20. How High Blood Pressure Can Lead to Stroke

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More How High Blood Pressure Can Lead to Stroke Updated:Jan 29,2018 ... stroke This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...