Sample records for talvised tulbid tee

  1. Transesophageal echocardiography (TEE) in atrial fibrillation.

    PubMed

    Thamilarasan, M; Klein, A L

    2000-11-01

    Transesophageal echocardiography has given new insight into the pathogenesis of the thromboembolic sequelae of AF and expanded the available therapeutic options. Studies to date indicate that TEE-guided cardioversion is a safe and reasonable approach when the clinical situation warrants prompt restoration of sinus rhythm. Whether widespread use of this strategy offers further benefit remains to be established, although there are theoretical advantages to such an approach. The potential for earlier cardioversion using a TEE-guided approach may facilitate the achievement and maintenance of sinus rhythm. In the long term, earlier restoration of sinus rhythm prevents adverse atrial remodeling, lowers embolic risk, and may improve cardiac performance and functional status. Thromboembolic sequelae (either cardioversion-related or as a result of chronic AF) remain the most devastating complications of AF. Every attempt to minimize this risk should be pursued aggressively. Information gathered from TEE has helped to elucidate the mechanisms responsible for postcardioversion embolism and has emphasized the importance of anticoagulation during and after the restoration of sinus rhythm. TEE also has the potential to further risk stratify patients with AF. Ultimately, a subset of patients may be identified who require more intense anticoagulation (i.e., those with dense SEC or thrombus, or persistent thrombus after prolonged anticoagulation) or in whom cardioversion may be deferred entirely. Likewise, TEE also may prove to be useful in identifying patients with a low-clinical risk profile who may be treated with aspirin alone and patients in whom warfarin may be superior. The results of the ACUTE study should help to further define the role of TEE in the management of patients with AF. Additional clinical studies are needed to address some of the issues that have been raised and to allow for optimal use of TEE in this patient population.

  2. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  3. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  4. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  5. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  6. Construction of prestressed concrete single-tee bridge superstructures.

    DOT National Transportation Integrated Search

    1977-01-01

    This report discusses in detail the construction of the first five precast, prestressed concrete, single-tee beam bridge superstructures to be let to contract in Virginia. The data suggest that this single-tee beam enables efficient construction of t...

  7. TEES 2.2: Biomedical Event Extraction for Diverse Corpora

    PubMed Central

    2015-01-01

    Background The Turku Event Extraction System (TEES) is a text mining program developed for the extraction of events, complex biomedical relationships, from scientific literature. Based on a graph-generation approach, the system detects events with the use of a rich feature set built via dependency parsing. The TEES system has achieved record performance in several of the shared tasks of its domain, and continues to be used in a variety of biomedical text mining tasks. Results The TEES system was quickly adapted to the BioNLP'13 Shared Task in order to provide a public baseline for derived systems. An automated approach was developed for learning the underlying annotation rules of event type, allowing immediate adaptation to the various subtasks, and leading to a first place in four out of eight tasks. The system for the automated learning of annotation rules is further enhanced in this paper to the point of requiring no manual adaptation to any of the BioNLP'13 tasks. Further, the scikit-learn machine learning library is integrated into the system, bringing a wide variety of machine learning methods usable with TEES in addition to the default SVM. A scikit-learn ensemble method is also used to analyze the importances of the features in the TEES feature sets. Conclusions The TEES system was introduced for the BioNLP'09 Shared Task and has since then demonstrated good performance in several other shared tasks. By applying the current TEES 2.2 system to multiple corpora from these past shared tasks an overarching analysis of the most promising methods and possible pitfalls in the evolving field of biomedical event extraction are presented. PMID:26551925

  8. TEES 2.2: Biomedical Event Extraction for Diverse Corpora.

    PubMed

    Björne, Jari; Salakoski, Tapio

    2015-01-01

    The Turku Event Extraction System (TEES) is a text mining program developed for the extraction of events, complex biomedical relationships, from scientific literature. Based on a graph-generation approach, the system detects events with the use of a rich feature set built via dependency parsing. The TEES system has achieved record performance in several of the shared tasks of its domain, and continues to be used in a variety of biomedical text mining tasks. The TEES system was quickly adapted to the BioNLP'13 Shared Task in order to provide a public baseline for derived systems. An automated approach was developed for learning the underlying annotation rules of event type, allowing immediate adaptation to the various subtasks, and leading to a first place in four out of eight tasks. The system for the automated learning of annotation rules is further enhanced in this paper to the point of requiring no manual adaptation to any of the BioNLP'13 tasks. Further, the scikit-learn machine learning library is integrated into the system, bringing a wide variety of machine learning methods usable with TEES in addition to the default SVM. A scikit-learn ensemble method is also used to analyze the importances of the features in the TEES feature sets. The TEES system was introduced for the BioNLP'09 Shared Task and has since then demonstrated good performance in several other shared tasks. By applying the current TEES 2.2 system to multiple corpora from these past shared tasks an overarching analysis of the most promising methods and possible pitfalls in the evolving field of biomedical event extraction are presented.

  9. CATS landline installed beneath the river Tees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Press Construction Ltd. has completed installation of the land portion of a new gas pipeline from the North Sea, including a tunnel beneath the River Tees in the north of England. The work was carried out under a multi-million dollar contract from Amoco (UK) Exploration Co. The pipeline is the land portion of the Central Area Transmission System. The 4.6-mile, 36-in. onshore pipeline connects a valve station at the CATS landfall at Coatham Sands, just south of Tees Bay, to a gas terminal north of the River Tees. This paper reports on the entire CATS system which runs for nearlymore » 250 miles from a riser platform in the Central Graben area of the North Sea to the Coatham Sands landfall and then overland to the gas terminal. The gas will fuel a new combined heat-and-power generating plant on Teesside, currently under construction by Teesside Power.« less

  10. Forensic testing of a double tee bridge.

    DOT National Transportation Integrated Search

    2014-12-01

    This report describes an investigation to quantify the behavior of precast, prestressed concrete double-tee bridge : girders made with lightweight concrete. As part of the investigation, three bridge girders were salvaged from a : decommissioned brid...

  11. Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

    NASA Technical Reports Server (NTRS)

    Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.

    2001-01-01

    Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

  12. Insights into the Mechanism of Severe Mitral Regurgitation: RT-3D TEE Guided Management with Pathological Correlation.

    PubMed

    Anand, Senthil; Hamoud, Naktal; Thompson, Jess; Janardhanan, Rajesh

    2015-01-01

    Mitral valve perforation is an uncommon but important complication of infective endocarditis. We report a case of a 65-year-old man who was diagnosed to have infective endocarditis of his mitral valve. Through the course of his admission he had a rapid development of hemodynamic instability and pulmonary edema secondary to acutely worsening mitral regurgitation. While the TEE demonstrated an increase in the size of his bacterial vegetation, Real Time 3D TEE was ultimately the imaging modality through which the valve perforation was identified. Through this case report we discuss the advantages that RT-3D TEE has over traditional 2D TEE in the management of valve perforation.

  13. Elasto-Plastic Analysis of Tee Joints Using HOT-SMAC

    NASA Technical Reports Server (NTRS)

    Arnold, Steve M. (Technical Monitor); Bednarcyk, Brett A.; Yarrington, Phillip W.

    2004-01-01

    The Higher Order Theory - Structural/Micro Analysis Code (HOT-SMAC) software package is applied to analyze the linearly elastic and elasto-plastic response of adhesively bonded tee joints. Joints of this type are finding an increasing number of applications with the increased use of composite materials within advanced aerospace vehicles, and improved tools for the design and analysis of these joints are needed. The linearly elastic results of the code are validated vs. finite element analysis results from the literature under different loading and boundary conditions, and new results are generated to investigate the inelastic behavior of the tee joint. The comparison with the finite element results indicates that HOT-SMAC is an efficient and accurate alternative to the finite element method and has a great deal of potential as an analysis tool for a wide range of bonded joints.

  14. Mixing at double-Tee junctions with unequal pipe sizes in ...

    EPA Pesticide Factsheets

    Pipe flow mixing with various solute concentrations and flow rates at pipe junctions is investigated. The degree of mixing affects the spread of contaminants in a water distribution system. Many studies have been conducted on the mixing at the cross junctions. Yet a few have focused on double-Tee junctions of unequal pipe sizes. To investigate the solute mixing at double-Tee junctions with unequal pipe sizes, a series of experiments were conducted in a turbulent regime (Re=12500–50000) with different Reynolds number ratios and connecting pipe lengths. It is shown that dimensionless outlet concentrations depended on mixing mechanism at the impinging interface of junctions. Junction with a larger pipe size ratio is associated with more complete mixing. The inlet Reynolds number ratio affects mixing more strongly than the outlet Reynolds number ratio. Furthermore, the dimensionless connecting pipe length in a double-Tee played an important and complicated role in the flow mixing. Based on these results, two-dimensional isopleth maps were developed for the calculation of normalized north outlet concentration. This journal article is to communicate the research results on pipe juncture mixing, a widespread and important phenomena in distribution system water quality analysis. The research outcome improves EPANET modeling capability for safe water supplies. In addition, the research is one of the outputs from the EPA-MOST bilateral cooperative research Project #1

  15. Transesophageal echocardiography in critically ill acute postoperative infants: comparison of AcuNav intracardiac echocardiographic and microTEE miniaturized transducers.

    PubMed

    Ferns, Sunita; Komarlu, Rukmini; Van Bergen, Andrew; Multani, Kanwar; Cui, Vivian Wei; Roberson, David A

    2012-08-01

    Multiple barriers to transthoracic echocardiography are present in critically ill infants immediately after surgery. Transesophageal echocardiography (TEE) is sometimes needed to obtain specific important information that transthoracic echocardiography fails to demonstrate. Formerly, the investigators used the AcuNav intracardiac echocardiographic (ICE) intravascular ultrasound transducer (8 Fr, 2.5 mm, 64-element crystal array, multifrequency [5.5-10 MHz], single longitudinal plane, linear phased array [Siemens Medical Solutions USA, Inc., Mountain View, CA]). Recently, the investigators have also used the microTEE transducer (8-mm transducer tip, 5.2-mm shaft, multifrequency [3-8 MHz], multiplane phased array, 32-element probe [Philips Medical Systems, Andover, MA]). Both transducers have two-dimensional, M-mode, color Doppler, and pulsed-wave and continuous-wave Doppler capabilities. The aim of this study was to compare the efficacy, safety, ease of insertion, capabilities, utilization, and cost of the AcuNav ICE transducer versus those of the microTEE transducer. A retrospective review of all 50 postoperative critically ill infants who underwent TEE using the AcuNav and microTEE in the past 5 years was conducted. TEE was performed as ordered by the attending physician to answer a specific question not answered by transthoracic echocardiography. In all cases, the clinical information sought was obtained. The AcuNav ICE transducer was safe, easy to insert through the transnasal route, and did not require paralysis; however, it had a limited number of echocardiographic views and had greater sterilization cost. The microTEE transducer had greater echocardiographic capabilities and lower sterilization cost; however, it was slightly more difficult to insert, had a few manageable complications, and required more sedation and paralysis. TEE in this setting has increased because of demonstrated efficacy and safety. Both the AcuNav ICE and microTEE transducers are useful

  16. 12. View underside of bridge, showing concrete tee beam deck ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. View underside of bridge, showing concrete tee beam deck spans supported by concrete piles, looking southwest - Colonel Alexander Scammell Memorial Bridge, Spanning Bellamy River at U.S. Route 4, Dover, Strafford County, NH

  17. The use of TEE simulation in teaching basic echocardiography skills to senior anesthesiology residents.

    PubMed

    Jelacic, Srdjan; Bowdle, Andrew; Togashi, Kei; VonHomeyer, Peter

    2013-08-01

    The authors evaluated the educational benefits of using a first-generation HeartWorks simulator to teach senior anesthesiology residents basic echocardiography skills. Prospective observational study. A single academic medical center (teaching hospital). Thirty-seven senior (fourth-year) anesthesiology residents participated in this study. Groups of 3 senior anesthesiology residents participated in a single 3-hour tutorial in the simulation laboratory in the authors' institution during their cardiothoracic anesthesiology rotation. A cardiothoracic anesthesiology faculty member demonstrated the use of the transesophageal echocardiography (TEE) simulator and instructed the residents on obtaining standard TEE views of normal anatomy. Prior to the laboratory session, the residents took an online multiple-choice pretest with 25 questions related to safety, probe manipulation, clinical application, and pathology, which was accompanied by echo images of normal cardiac anatomy and video clips of pathology. Three to four weeks after the TEE tutorial, the residents completed an online post-test and evaluation of the teaching session. There was a statistically significant increase in knowledge of normal echocardiographic anatomy (p = 0.04), with an average improvement in normal echocardiographic anatomy scores of 15%. Virtual reality TEE simulation technology was endorsed strongly by residents, produced a statistically significant improvement in knowledge of normal echocardiographic anatomy, and could be effective for teaching basic echocardiography to anesthesiology residents. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. 18. DETAILED OFFSHORE VIEW OF 4TH TEE, LOOKING NORTHWEST, SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAILED OFFSHORE VIEW OF 4TH TEE, LOOKING NORTHWEST, SHOWING TRANSITION FROM WOOD BENTS TO CONCRETE BENTS - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  19. Guidelines for Conducting a Training Effectiveness Evaluation (TEE). Volume 2. Data Collector’s Manual

    DTIC Science & Technology

    1985-02-01

    D : ■>■■ ’•.’.’. Research Product 85-15 Guidelines for Conducting a Training Effectiveness Evaluation (TEE) Volume II: Data...CONDUCTING A TRAINING EFFECTIVENESS EVALUATION (TEE) VOLUME II: DATA COLLECTOR’S MANUAL 1 t. TV*CO» READ INSTRUCTIONS BEFORE COMWLETWC FORM I...2Q263739A793 3227 52A M. COMTAOLUMQ O’ttCC RAMC AND ADO* CSS Co—and ant U.S. Army Air Defense School ATTN: ATSA-TDI, Ft. Bliss, TX II. RCRORf OATC

  20. High temperature lined conduits, elbows and tees

    DOEpatents

    De Feo, Angelo; Drewniany, Edward

    1982-01-01

    A high temperature lined conduit comprising, a liner, a flexible insulating refractory blanket around and in contact with the liner, a pipe member around the blanket and spaced therefrom, and castable rigid refractory material between the pipe member and the blanket. Anchors are connected to the inside diameter of the pipe and extend into the castable material. The liner includes male and female slip joint ends for permitting thermal expansion of the liner with respect to the castable material and the pipe member. Elbows and tees of the lined conduit comprise an elbow liner wrapped with insulating refractory blanket material around which is disposed a spaced elbow pipe member with castable refractory material between the blanket material and the elbow pipe member. A reinforcing band is connected to the elbow liner at an intermediate location thereon from which extend a plurality of hollow tubes or pins which extend into the castable material to anchor the lined elbow and permit thermal expansion. A method of fabricating the high temperature lined conduit, elbows and tees is also disclosed which utilizes a polyethylene layer over the refractory blanket after it has been compressed to maintain the refractory blanket in a compressed condition until the castable material is in place. Hot gases are then directed through the interior of the liner for evaporating the polyethylene and setting the castable material which permits the compressed blanket to come into close contact with the castable material.

  1. The microwave Hall effect measured using a waveguide tee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coppock, J. E.; Anderson, J. R.; Johnson, W. B.

    2016-03-14

    This paper describes a simple microwave apparatus to measure the Hall effect in semiconductor wafers. The advantage of this technique is that it does not require contacts on the sample or the use of a resonant cavity. Our method consists of placing the semiconductor wafer into a slot cut in an X-band (8–12 GHz) waveguide series tee, injecting microwave power into the two opposite arms of the tee, and measuring the microwave output at the third arm. A magnetic field applied perpendicular to the wafer gives a microwave Hall signal that is linear in the magnetic field and which reverses phasemore » when the magnetic field is reversed. The microwave Hall signal is proportional to the semiconductor mobility, which we compare for calibration purposes with d.c. mobility measurements obtained using the van der Pauw method. We obtain the resistivity by measuring the microwave reflection coefficient of the sample. This paper presents data for silicon and germanium samples doped with boron or phosphorus. The measured mobilities ranged from 270 to 3000 cm{sup 2}/(V s).« less

  2. Fatigue and shear behavior of HPC bulb-tee girders: final report.

    DOT National Transportation Integrated Search

    2005-02-01

    Five 96-ft. (29.3-m) long, 72-in. (1.83-m) deep, precast, pretensioned bulb-tee girders were tested to evaluate their behavior under flexural fatigue. Three of the girders were also tested to measure their static shear strength. One girder was tested...

  3. Fatigue and shear behavior of HPC bulb-tee girders : interim report.

    DOT National Transportation Integrated Search

    2003-10-01

    Three 96-ft (29.3-m) long, 72-in. (1.83-m) deep, precast, pretensioned bulb-tee girders were tested to evaluate behavior under flexural fatigue and static shear loadings. The three girders had a design concrete compressive strength of 10,000 psi (69....

  4. Evaluation of the inverted tee shallow bridge system for use in Kansas

    DOT National Transportation Integrated Search

    2006-12-01

    With the introduction of the pre-stressed concrete Inverted Tee (IT) girders as an alternative to the conventional concrete slab bridges, the distribution of live load in this system required considerable investigation. The approximate equations give...

  5. 94. VIEW OF PILINGS ON SOUTHEAST SIDE, WITH 4TH TEE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    94. VIEW OF PILINGS ON SOUTHEAST SIDE, WITH 4TH TEE IN THE BACKGROUND, FACING WEST-SOUTHWEST FROM SOUTHEAST CORNER OF THE TACKLE BOX. RAMP OF PIER EXTENSION IS VISIBLE ON RIGHT - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  6. ADDING GLYCERINE TO ECO-FRIENDLY GOLF TEES TO ACCELERATE BIODEGRADABILITY AND IMPROVE FABRICATION

    EPA Science Inventory

    It is expected that a suitable combination of DDGS and glycerine with PLA as well as a corresponding blend with corn-starch will be found. These blends will be applicable to a commercial, biodegradable golf tee with superior environmental properties, compared to what is on the...

  7. Live 3D TEE demonstrates and guides the management of prosthetic mitral valve obstruction.

    PubMed

    Chahal, Mangeet; Pandya, Utpal; Adlakha, Satjit; Khouri, Samer J

    2011-08-01

    A 43-year-old woman, with a remote history of rheumatic mitral stenosis and a St. Jude prosthetic mitral valve replacement, presented with shortness of breath and palpitations, shortly after a long flight. On admission, atrial fibrillation with a rapid ventricular response was noted in the setting of a long history of noncompliance with her anticoagulation. Transesophageal echocardiography (TEE) demonstrated multiple laminated thrombi in the left atrial appendage. Live three-dimensional (3D) TEE confirmed this diagnosis and demonstrated an immobile posterior leaflet of the mitral prosthesis, which had direct implications in her management. She successfully underwent surgery for mitral valve replacement, left atrial appendage ligation, and a Maze procedure on the following day. The multiple thrombi within the atrial appendage were confirmed intraoperatively and pannus formation was determined to be the etiology of the leaflet immobility. © 2011, Wiley Periodicals, Inc.

  8. Investigation of Dispersed and Dispersed Annular (rivulet or Thin Film) Flow Phase Separation in Tees.

    NASA Astrophysics Data System (ADS)

    McCreery, Glenn Ernest

    An experimental and analytical investigation of dispersed and dispersed-annular (rivulet or thin film) flow phase separation in tees has been successfully completed. The research was directed at, but is not specific to, determining flow conditions, following a loss of coolant accident, in the large rectangular passageways leading to vacuum buildings in the containment envelope of some CANDU nuclear reactors. The primary objectives of the research were to: (1) obtain experimental data to help formulate and test mechanistic analytical models of phase separation, and (2) develop the analytical models in computer programs which predict phase separation from upstream flow and pressure conditions and downstream and side branch pressure boundary conditions. To meet these objectives an air-water experimental apparatus was constructed, and consists of large air blowers attached to a long rectangular duct leading to a tee in the horizontal plane. A variety of phenomena was investigated including, for comparison with computer predictions, air streamlines and eddy boundary geometry, drop size spectra, macroscopic mass balances, liquid rivulet pathlines, and trajectories of drops of known size and velocity. Four separate computer programs were developed to analyze phase separation. Three of the programs are used sequentially to calculate dispersed mist phase separation in a tee. The fourth is used to calculate rivulet or thin film pathlines. Macroscopic mass balances are calculated from a summation of mass balances for drops with representative sizes (and masses) spaced across the drop size spectrum. The programs are tested against experimental data, and accurately predict gas flow fields, drop trajectories, rivulet pathlines and macroscopic mass balances. In addition to development of the computer programs, analysis was performed to specify the scaling of dispersed mist and rivulet or thin film flow, to investigate pressure losses in tees, and the inter-relationship of loss

  9. Evaluation of "The First Tee" in Promoting Positive Youth Development: Group Comparisons and Longitudinal Trends

    ERIC Educational Resources Information Center

    Weiss, Maureen R.; Bolter, Nicole D.; Kipp, Lindsay E.

    2016-01-01

    Purpose: This manuscript represents the 3rd in a series of articles documenting our longitudinal evaluation of "The First Tee," a physical activity-based youth development program that uses golf as a vehicle for teaching life skills and enhancing developmental outcomes. Previous phases of our project: (a) established initial data-based…

  10. A descriptive study of step alignment and foot positioning relative to the tee by professional rugby union goal-kickers.

    PubMed

    Cockcroft, John; Van Den Heever, Dawie

    2016-01-01

    This study describes foot positioning during the final two steps of the approach to the ball amongst professional rugby goal-kickers. A 3D optical motion capture system was used to test 15 goal-kickers performing 10 goal-kicks. The distance and direction of each step, as well as individual foot contact positions relative to the tee, were measured. The intra- and inter-subject variability was calculated as well as the correlation (Pearson) between the measurements and participant anthropometrics. Inter-subject variability for the final foot position was lowest (placed 0.03 ± 0.07 m behind and 0.33 ± 0.03 m lateral to the tee) and highest for the penultimate step distance (0.666 ± 0.149 m), performed at an angle of 36.1 ± 8.5° external to the final step. The final step length was 1.523 ± 0.124 m, executed at an external angle of 35.5 ± 7.4° to the target line. The intra-subject variability was very low; distances and angles for the 10 kicks varied per participant by 1.6-3.1 cm and 0.7-1.6°, respectively. The results show that even though the participants had variability in their run-up to the tee, final foot position next to the tee was very similar and consistent. Furthermore, the inter- and intra-subject variability could not be attributed to differences in anthropometry. These findings may be useful as normative reference data for coaching, although further work is required to understand the role of other factors such as approach speed and body alignment.

  11. "The First Tee: Building Character Education." Hearing before the Committee on Education and the Workforce. House of Representatives, One Hundred Sixth Congress, Second Session (June 25, 2002).

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Education and the Workforce.

    This publication covers the U.S. House of Representatives June 25, 2002, hearing on building character education through the "First Tee" program in U.S. public schools. The First Tee is a youth character-building organization with programs located throughout the country. It provides young people of all backgrounds the opportunity to…

  12. Subject-specific finite-element modeling of normal aortic valve biomechanics from 3D+t TEE images.

    PubMed

    Labrosse, Michel R; Beller, Carsten J; Boodhwani, Munir; Hudson, Christopher; Sohmer, Benjamin

    2015-02-01

    In the past decades, developments in transesophageal echocardiography (TEE) have opened new horizons in reconstructive surgery of the aortic valve (AV), whereby corrections are made to normalize the geometry and function of the valve, and effectively treat leaks. To the best of our knowledge, we propose the first integrated framework to process subject-specific 3D+t TEE AV data, determine age-matched material properties for the aortic and leaflet tissues, build a finite element model of the unpressurized AV, and simulate the AV function throughout a cardiac cycle. For geometric reconstruction purposes, dedicated software was created to acquire the 3-D coordinates of 21 anatomical landmarks of the AV apparatus in a systematic fashion. Measurements from ten 3D+t TEE datasets of normal AVs were assessed for inter- and intra-observer variability. These tests demonstrated mean measurement errors well within the acceptable range. Simulation of a complete cardiac cycle was successful for all ten valves and validated the novel schemes introduced to evaluate age-matched material properties and iteratively scale the unpressurized dimensions of the valves such that, given the determined material properties, the dimensions measured in vivo closely matched those simulated in late diastole. The leaflet coaptation area, describing the quality of the sealing of the valve, was measured directly from the medical images and was also obtained from the simulations; both approaches correlated well. The mechanical stress values obtained from the simulations may be interpreted in a comparative sense whereby higher values are indicative of higher risk of tearing and/or development of calcification. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Trouble and Triumph: German Life-Turkish Tradition in Renan Demirkan's "Schwarzer Tee mit drei Stuck Zucker"

    ERIC Educational Resources Information Center

    Ebert, Reika

    2004-01-01

    This paper explores Demirkan's narrative strategies in "Schwarzer Tee mit drei Stuck Zucker" to negotiate issues of a life between two cultures and traditions. Based on Bhabha's insights that mainstream culture needs intellectual and artistic infusion from the margins of a society in order to remain vital; and that cultural production…

  14. Automatic detection of cardiac cycle and measurement of the mitral annulus diameter in 4D TEE images

    NASA Astrophysics Data System (ADS)

    Graser, Bastian; Hien, Maximilian; Rauch, Helmut; Meinzer, Hans-Peter; Heimann, Tobias

    2012-02-01

    Mitral regurgitation is a wide spread problem. For successful surgical treatment quantification of the mitral annulus, especially its diameter, is essential. Time resolved 3D transesophageal echocardiography (TEE) is suitable for this task. Yet, manual measurement in four dimensions is extremely time consuming, which confirms the need for automatic quantification methods. The method we propose is capable of automatically detecting the cardiac cycle (systole or diastole) for each time step and measuring the mitral annulus diameter. This is done using total variation noise filtering, the graph cut segmentation algorithm and morphological operators. An evaluation took place using expert measurements on 4D TEE data of 13 patients. The cardiac cycle was detected correctly on 78% of all images and the mitral annulus diameter was measured with an average error of 3.08 mm. Its full automatic processing makes the method easy to use in the clinical workflow and it provides the surgeon with helpful information.

  15. A loading study of older highway bridges in Virginia. Pt. 3, Concrete tee-beam bridge in Nelson County.

    DOT National Transportation Integrated Search

    1977-01-01

    A 40-foot clear span, standard reinforced tee-beam bridge over the Tye River in Nelson County was tested with a 23-ton, tandem axle test vehicle in July 1976. The test span was one of four identical spans making a total bridge length of 170 feet. Str...

  16. Tension pneumomediastnum: A rare cause of acute intraoperative circulatory collapse in the setting of unremarkable TEE findings.

    PubMed

    Weaver, Jonathan B; Kumar, Avinash B

    2017-02-01

    Case report. Operating room. 25YF, ASA IV E who underwent an emergent decompressive craniectomy for refractory intracranial hypertension secondary to acute intracranial hemorhage. A 25Y caucasian female presented with acute intracranial hemorrhage with intraventricular extension secondary to Moya Moya disease. Post admisison, she underwent an emergent decompressive craniectomy for medically refractory intracranial hypertension. Introperatively (post dural closure and bone flap removal) the patient developed acutely worsening peak and plateau pressures followed by pulseless electrical activity necessitating CPR with epinephrine and Vasopressin before return of circulation before return of circulation. Intraoperative TEE done during return of circulation, was essentially non diagnostic, the patient had normal breath sounds throughout, and non-contributory bronchoscopy findings. EKG, arterial blood pressure, heart rate, resp. rate, introperative tranesophageal echocardiogram (TEE), Pulse oximetry, serial arterial blood gases, introperative bronchoscopy, ventilatory peak pressures. A post operative chest CT revealed extensive pneumomediastinum with subcutaneous emphysema. The focussed introperative echocardiogram showed preserved left ventricular function and no evidence of tamponade physiology. Tension pneumomediastinum was the likely etiologic factor for the acute hemodynamic collapse and should be considered in the differential diagnosis of intraoperative circulatory arrest. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. 3D Assessment of Features Associated With Transvalvular Aortic Regurgitation After TAVR: A Real-Time 3D TEE Study.

    PubMed

    Shibayama, Kentaro; Mihara, Hirotsugu; Jilaihawi, Hasan; Berdejo, Javier; Harada, Kenji; Itabashi, Yuji; Siegel, Robert; Makkar, Raj R; Shiota, Takahiro

    2016-02-01

    This study of 3-dimensional (3D) transesophageal echocardiography (TEE) aimed to demonstrate features associated with transvalvular aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) and to confirm the fact that a gap between the native aortic annulus and prosthesis is associated with paravalvular AR. The mechanism of AR after TAVR, particularly that of transvalvular AR, has not been evaluated adequately. All patients with severe aortic stenosis who underwent TAVR with the Sapien device (Edwards Lifesciences, Irvine, California) had 3D TEE of the pre-procedural native aortic annulus and the post-procedural prosthetic valve. In the 201 patients studied, the total AR was mild in 67 patients (33%), moderate in 21 patients (10%), and severe in no patients. There were 20 patients with transvalvular AR and 82 patients with paravalvular AR. Fourteen patients had both transvalvular and paravalvular AR. Patients with transvalvular AR had larger prosthetic expansion (p <0.05), a more elliptical prosthetic shape at the prosthetic commissure level (p <0.01) and more anti-anatomical position (p <0.001), which was defined as malposition of the prosthetic commissures in relation to the native commissures, than the patients without transvalvular AR. Age (odds ratio [OR]: 1.05; 95% confidence interval [CI]: 1.01 to 1.09; p < 0.05) and effective area oversizing (OR: 0.97; 95% CI: 0.93 to 0.99, p <0.05) were associated with mild or greater paravalvular AR. 3D TEE successfully demonstrated the features associated with transvalvular AR, such as large prosthetic expansion, elliptical prosthetic shape, and anti-anatomical position of prosthesis. Additionally, effective area oversizing was associated with paravalvular AR. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Beyond the static image: Tee Corinne's roles as a pioneering lesbian artist and art historian.

    PubMed

    Snider, Stefanie

    2013-01-01

    While Tee Corinne has been widely recognized as a preeminent lesbian and feminist artist of the last forty years, little has been written about her as an artist or art historian in any substantial way. This article attempts to shed light on Corinne's investment in creating explicitly sexual lesbian visual art and art historical writings that put pressure on the categories of artist and art historian between the 1970s and early 2000s. Corinne's work manages to fulfill feminist ideals while also working outside of the norms set up in both the lesbian and mainstream realms of art and art history.

  19. Geometry of the left ventricular outflow tract assessed by 3D TEE in patients with aortic stenosis: impact of upper septal hypertrophy on measurements of Doppler-derived left ventricular stroke volume.

    PubMed

    Koto, Dan; Izumo, Masaki; Machida, Takafumi; Suzuki, Kengo; Yoneyama, Kihei; Suzuki, Tomomi; Kamijima, Ryo; Kobayashi, Yasuyuki; Harada, Tomoo; Akashi, Yoshihiro J

    2018-05-24

    It is unclear how upper septal hypertrophy (USH) affects Doppler-derived left ventricular stroke volume (SV) in patients with AS. The aims of this study were to: (1) validate the accuracy of 3D transesophageal echocardiography (TEE) measurements of the left ventricular outflow tract (LVOT), (2) evaluate the differences in LVOT geometry between AS patients with and without USH, and (3) assess the impact of USH on measurement of SV. In protocol 1, both 3D TEE and multi-detector computed tomography were performed in 20 patients with AS [aortic valve area (AVA) ≤ 1.5 cm 2 ]. Multiplanar reconstruction was used to measure the LVOT short and long diameters in four parts from the tip of the septum to the annulus. In protocol 2, the same 3D TEE measurements were performed in AS patients (AVA ≤ 1.5 cm 2 , n = 129) and controls (n = 30). We also performed 2D and 3D transthoracic echocardiography in all patients. In protocol 1, excellent correlations of LVOT parameters were found between the two modalities. In protocol 2, the USH group had smaller LVOT short and long diameters than the non-USH group. Although no differences in mean pressure gradient, or SV calculated with the 3D method existed between the two groups, the USH group had greater SV calculated with the Doppler method (73 ± 15 vs. 66 ± 15 ml) and aortic valve area (0.89 ± 0.26 vs. 0.73 ± 0.24 cm 2 ) than the non-USH group. 3D TEE can provide a precise assessment of the LVOT in AS. USH affects the LVOT geometry in patients with AS, which might lead to inaccurate assessments of disease severity.

  20. Inequalities in mental health and well-being in a time of austerity: Baseline findings from the Stockton-on-Tees cohort study.

    PubMed

    Mattheys, K; Bambra, C; Warren, J; Kasim, A; Akhter, N

    2016-12-01

    Since 2010, the UK has pursued a policy of austerity characterised by public spending cuts and welfare changes. There has been speculation - but little actual research - about the effects of this policy on health inequalities. This paper reports on a case study of local health inequalities in the local authority of Stockton-on-Tees in the North East of England, an area characterised by high spatial and socio-economic inequalities. The paper presents baseline findings from a prospective cohort study of inequalities in mental health and mental wellbeing between the most and least deprived areas of Stockton-on-Tees. This is the first quantitative study to explore local mental health inequalities during the current period of austerity and the first UK study to empirically examine the relative contributions of material, psychosocial and behavioural determinants in explaining the gap. Using a stratified random sampling technique, the data was analysed using multi-level models that explore the gap in mental health and wellbeing between people from the most and least deprived areas of the local authority, and the relative contributions of material, psychosocial and behavioural factors to this gap. The main findings indicate that there is a significant gap in mental health between the two areas, and that material and psychosocial factors appear to underpin this gap. The findings are discussed in relation to the context of the continuing programme of welfare changes and public spending cuts in the UK.

  1. Estrogenic alkylphenols in fish tissues, sediments, and waters from the U.K. Tyne and Tees estuaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lye, C.M.; Frid, C.L.J.; Gill, M.E.

    1999-04-01

    Nonylphenols and related compounds are common products of biodegradation of a large group of nonionic surfactants, the nonylphenol polyethoxylates. Many of these compounds are known to be environmentally persistent and to elicit estrogenic response in both mammals and fish. In this study, nonylphenol (NP), nonylphenol monoethoxylate (NP1EO), and octylphenol (OP) were found in tissues of mature male flounder, Platichthys flesus, and in tissues of juvenile flounder. These fish also showed detectable levels of the yolk protein vitellogenin in their plasma, indicative of estrogenic exposure. The compounds were also found in discharges from a major sewage treatment works and in sedimentsmore » from two estuaries in north-east England; the highest levels from the highly industrialized Tees and lower levels from the industrialized/urbanized Tyne estuary. The implications of these findings for fish populations are discussed.« less

  2. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE.

    PubMed

    Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  3. Geographical inequalities in health in a time of austerity: Baseline findings from the Stockton-on-Tees cohort study.

    PubMed

    Bhandari, R; Kasim, A; Warren, J; Akhter, N; Bambra, C

    2017-11-01

    Stockton-on-Tees has the highest geographical inequalities in health in England with the life expectancy at birth gap between the most and deprived neighbourhoods standing at over 17 years for men and 11 years for women. In this study, we provide the first detailed empirical examination of this geographical health divide by: estimating the gap in physical and general health (as measured by EQ. 5D, EQ. 5D-VAS and SF8PCS) between the most and least deprived areas; using a novel statistical technique to examining the causal role of compositional and contextual factors and their interaction; and doing so in a time of economic recession and austerity. Using a stratified random sampling technique, individual-level survey data was combined with secondary data sources and analysed using multi-level models with 95% confidence intervals obtained from nonparametric bootstrapping. The main findings indicate that there is a significant gap in health between the two areas, and that compositional level material factors, contextual factors and their interaction appear to be the major explanations of this gap. Contrary to the dominant policy discourse in this area, individual behavioural and psychosocial factors did not make a significant contribution towards explaining health inequalities in the study area. The findings are discussed in relation to geographical theories of health inequalities and the context of austerity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Total energy expenditure estimated using foot-ground contact pedometry.

    PubMed

    Hoyt, Reed W; Buller, Mark J; Santee, William R; Yokota, Miyo; Weyand, Peter G; Delany, James P

    2004-02-01

    Routine walking and running, by increasing daily total energy expenditure (TEE), can play a significant role in reducing the likelihood of obesity. The objective of this field study was to compare TEE estimated using foot-ground contact time (Tc)-pedometry (TEE(PEDO)) with that measured by the criterion doubly labeled water (DLW) method. Eight male U.S. Marine test volunteers [27 +/- 4 years of age (mean +/- SD); weight = 83.2 +/- 10.7 kg; height = 182.2 +/- 4.5 cm; body fat = 17.0 +/- 2.9%] engaged in a field training exercise were studied over 2 days. TEE(PEDO) was defined as (calculated resting energy expenditure + estimated thermic effect of food + metabolic cost of physical activity), where physical activity was estimated by Tc-pedometry. Tc-pedometry was used to differentiate inactivity, activity other than exercise (i.e., non-exercise activity thermogenesis, or NEAT), and the metabolic cost of locomotion (M(LOCO)), where M(LOCO) was derived from total weight (body weight + load weight) and accelerometric measurements of Tc. TEE(PEDO) data were compared with TEEs measured by the DLW (2H2(18)O) method (TEE(DLW)): TEE(DLW) = 15.27 +/- 1.65 MJ/day and TEE(PEDO) = 15.29 +/- 0.83 MJ/day. Mean bias (i.e., TEE(PEDO) - TEE(DLW)) was 0.02 MJ, and mean error (SD of individual differences between TEE(PEDO) and TEE(DLW)) was 1.83 MJ. The Tc-pedometry method provided a valid estimate of the average TEE of a small group of physically active subjects where walking was the dominant activity.

  5. Multinational institutional survey on patterns of intraoperative transesophageal echocardiography use in adult cardiac surgery.

    PubMed

    Dobbs, Heather A; Bennett-Guerrero, Elliott; White, William; Shernan, Stanton K; Nicoara, Alina; Del Rio, J Mauricio; Stafford-Smith, Mark; Swaminathan, Madhav

    2014-02-01

    To assess institutional patterns of perioperative transesophageal echocardiography (TEE) usage. The authors hypothesized that TEE is performed more frequently and comprehensively in academic centers, mainly by anesthesiologists, and barriers to performing TEE are due to inadequate resources. A survey was deployed to selected participants. Collated responses were assessed for demographic patterns in TEE practice, and 2-category comparisons were made with Chi-squared association tests. Web-based survey. Practitioners in cardiovascular anesthesia/surgery in 200 institutions. None. Surveys were completed by respondents representing 200 centers in 27 countries and 1,727 anesthesiologists with a mean annual institutional volume of 924 cases. Most centers were in the USA (53%) and were defined as academic (83%). Anesthesiologists performed (85%) and also read/reported TEEs (78%) in most centers. Three-dimensional TEE is performed routinely at 40% of centers. TEE is used routinely for valve surgery in 95% of institutions compared to 68% for coronary artery bypass graft surgery. Academic institutions assessed diastolic function more often than nonacademic centers (46% v 19%; p = 0.006). The most important reason cited for not using TEE in all cases was insufficient resource availability (47%). These results suggest that TEE is performed more comprehensively in academic centers, mainly by anesthesiologists, and that lack of resources is a significant barrier to routine TEE usage. TEE is used more often for valve surgery than for coronary artery bypass graft surgery, and many centers use 3D TEE. This survey describes international TEE practice patterns and identifies limitations to universal adoption of TEE in cardiac surgery. © 2013 Elsevier Inc. All rights reserved.

  6. Total energy expenditure of 10- to 12-year-old Japanese children measured using the doubly labeled water method.

    PubMed

    Komura, Keisuke; Nakae, Satoshi; Hirakawa, Kazufumi; Ebine, Naoyuki; Suzuki, Kazuhiro; Ozawa, Haruo; Yamada, Yosuke; Kimura, Misaka; Ishii, Kojiro

    2017-01-01

    To establish Japanese children's estimated energy requirements, total energy expenditure (TEE) data measured using the doubly labeled water (DLW) method is needed. This study aimed to 1) obtain basic TEE data from Japanese children measured using DLW (TEE DLW ), 2) compare TEE DLW with TEE estimated by various estimation formulas to calculate their accuracy, and 3) develop a new equation to estimate TEE using body composition and pedometers. TEE was measured using DLW in 56 10- to 12-year-old Japanese children (33 boys, 23 girls). Physical activity level (PAL) was calculated by dividing TEE DLW by estimated resting energy expenditure. To assess their physical activity, participants wore pedometers during the 7-d DLW period. Total body water was calculated from 2 H and 18 O; fat-free mass (FFM) and fat mass (FM) were then determined. In boys and girls of normal weight, TEE DLW was 2067 ± 230 kcal/d and 1830 ± 262 kcal/d, respectively. Average PAL was 1.58 ± 0.17. FFM was strongly related to TEE ( r  = 0.702, p  < 0.01). After adjusting for FFM and FM, step count was significantly associated with TEE ( r  = 0.707, p  < 0.01). The TEE estimation formula used in the Dietary Reference Intakes (DRI) for the United States and Canada estimated TEE DLW with high accuracy (bias: 2.0%) in both sexes. We developed new equations for TEE consisting of FFM and step count, which accounted for 68% and 65% of TEE variance in boys and girls, respectively: boys, 47.1 × FFM (kg) + 0.0568 × step count (steps/d) - 122, and girls, 55.5 × FFM (kg) + 0.0315 × step count (steps/d) - 117. The TEE in 10- to 12-year-old Japanese children measured using DLW was approximately 7% lower for boys and 12% lower for girls compared to the current Japanese DRI. If PAL can be accurately determined, the equation in the DRI for the United States and Canada may be applicable to Japanese children. In addition, TEE could be predicted using FFM and step count.

  7. Validation of the Arizona Activity Frequency Questionnaire using doubly labeled water.

    PubMed

    Staten, L K; Taren, D L; Howell, W H; Tobar, M; Poehlman, E T; Hill, A; Reid, P M; Ritenbaugh, C

    2001-11-01

    Physical activity questionnaires (PAQs) are considered the most cost-efficient method to estimate total energy expenditure (TEE) in epidemiological studies. However, relatively few PAQs have been validated using doubly labeled water (DLW) in women or in samples with diverse ethnic backgrounds. This study was conducted to validate the Arizona Activity Frequency Questionnaire (AAFQ) for estimation of TEE and physical activity energy expenditure (PAEE) over 1 month using DLW as a reference method. Thirty-five relatively sedentary women completed the AAFQ before participating in an 8-d DLW protocol to measure TEE. TEE and PAEE were estimated from the AAFQ by calculating resting metabolic rate (RMR) using the equation of Mifflin et al. (AAFQmif), by measuring RMR using indirect calorimetry (AAFQic), and using MET conversion (AAFQmet). A predictive equation for TEE was generated. The mean +/- SD for TEE and PAEE from DLW were 9847 +/- 2555 kJ x d(-1) and 5578 +/- 2084 kJ x d(-1), respectively. Formulas using RMR to calculate the TEE and PAEE from the AAFQ tended to underestimate TEE and PAEE, whereas those that included only weight tended to overestimate TEE and PAEE. On the basis of the Mifflin et al. equation, the AAFQ tends to underestimate PAEE by 13%. This underestimation may be explained by the low lean body mass of the sample population and by effectiveness of the METs/RMR ratio in the obese. The following predictive equation was calculated: TEE (kJ x d(-1)) = (86.0 * average total daily METs) + (2.23 * RMRmif) - 6726. When the predictive equation is used, TEE calculated from the AAFQ is highly correlated with DLW TEE (adjusted r(2) = 0.70, P < 0.001). The AAFQ is an effective tool for the prediction of TEE and PAEE in epidemiological studies.

  8. Transesophageal echocardiography evaluation of the thoracic aorta

    PubMed Central

    Patil, T. A.; Nierich, Arno

    2016-01-01

    Transesophageal echocardiography (TEE) can be used to identify risk factors such as aortic atherosclerosis[2] before any sort of surgical manipulations involving aorta and its related structures. TEE has become an important noninvasive tool to diagnose acute thoracic aortic pathologies. TEE evaluation of endoleaks helps early detection and immediate corrective interventions. TEE is an invaluable imaging modality in the management of aortic pathology. TEE has to a large extent improved the patient outcomes. PMID:27762248

  9. Calculation versus measurement of total energy expenditure.

    PubMed

    van Lanschot, J J; Feenstra, B W; Vermeij, C G; Bruining, H A

    1986-11-01

    In acutely ill patients both hypo- and hyperalimentation must be avoided by adjusting caloric intake to total energy expenditure (TEE). We determined the discrepancy between basal energy expenditure (BEE) calculated from the basic Harris-Benedict formula and TEE measured by continuous indirect calorimetry in a heterogeneous group of mechanically ventilated surgical patients. We also compared the accuracy of TEE calculated from the corrected Harris-Benedict formula or estimated by intermittent indirect calorimetry to that of TEE measured by continuous indirect calorimetry. The poor correlation between calculated BEE and measured TEE was significantly (p less than .05) improved by a correction factor based on each patient's clinical condition. The mean absolute difference between calculated TEE and measured TEE was 8.9 +/- 9.6 (SD) %. Calculations were significantly (p less than .05) improved by estimating TEE from two 5-min recording periods, which suggests that continuous indirect calorimetry may not always be necessary to guide caloric replacement.

  10. Approaches for quantifying energy intake and %calorie restriction during calorie restriction interventions in humans: the multicenter CALERIE study.

    PubMed

    Racette, Susan B; Das, Sai Krupa; Bhapkar, Manjushri; Hadley, Evan C; Roberts, Susan B; Ravussin, Eric; Pieper, Carl; DeLany, James P; Kraus, William E; Rochon, James; Redman, Leanne M

    2012-02-15

    Calorie restriction (CR) is a component of most weight loss interventions and a potential strategy to slow aging. Accurate determination of energy intake and %CR is critical when interpreting the results of CR interventions; this is most accurately achieved using the doubly labeled water method to quantify total energy expenditure (TEE). However, the costs and analytical requirements of this method preclude its repeated use in many clinical trials. Our aims were to determine 1) the optimal TEE assessment time points for quantifying average energy intake and %CR during long-term CR interventions and 2) the optimal approach for quantifying short-term changes in body energy stores to determine energy intake and %CR during 2-wk DLW periods. Adults randomized to a CR intervention in the multicenter CALERIE study underwent measurements of TEE by doubly labeled water and body composition at baseline and months 1, 3, and 6. Average %CR achieved during the intervention was 24.9 ± 8.7%, which was computed using an approach that included four TEE assessment time points (i.e., TEE(baseline, months 1, 3, and 6)) plus the 6-mo change in body composition. Approaches that included fewer TEE assessments yielded %CR values of 23.4 ± 9.0 (TEE(baseline,) months 3 and 6), 25.0 ± 8.7 (TEE(baseline,) months 1 and 6), and 20.9 ± 7.1% (TEE(baseline, month 6)); the latter approach differed significantly from approach 1 (P < 0.001). TEE declined 9.6 ± 9.9% within 2-4 wk of CR beginning and then stabilized. Regression of daily home weights provided the most reliable estimate of short-term change in energy stores. In summary, optimal quantification of energy intake and %CR during weight loss necessitates a TEE measurement within the first month of CR to capture the rapid reduction in TEE.

  11. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    PubMed

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in children.

    PubMed

    Hascoet, Sébastien; Hadeed, Khaled; Marchal, Pauline; Dulac, Yves; Alacoque, Xavier; Heitz, Francois; Acar, Philippe

    2015-07-01

    A trans-catheter closure of an atrial septal defect (ASD) is efficient. Balloon sizing (BS) during the catheterization leads to an overestimation of ASD size. Three-dimensional transoesophageal echocardiography (3D-TEE) allows the ASD morphology to be assessed comprehensively. The aim of this study was to assess the relationships between the shape and the measurements of ASDs by 2D-, 3D-TEE, and BS in children. Thirty children who underwent percutaneous closures of a single ASD were enrolled. ASD diameters were measured by 2D-transthoracic echocardiography (TTE), 2D-TEE, 3D-TEE and compared with BS. The ASD area was measured on 3D-TEE images after multi-planar reconstruction. ASD was estimated as round or oval on 3D-TEE 'en-face' view. 2D-TTE, 2D-TEE, and 3D-TEE(max) ASD diameters were well correlated with BS (r = 0.75; 0.80, and 0.85, respectively). Mean diameters were all significantly smaller than the mean BS. The mean difference between the balloon area and 3D-TEE area was 1.6 ± 1.4 cm(2) (P < 0.0001). The mean difference between BS and 3D-TEE(max) diameters was higher in round ASDs than in oval ASDs (4.0 ± 3.3 vs. 1.1 ± 3.3, P = 0.02). With multivariate linear regression analysis, two formulas were built to predict BS. The first model was BS = 1.07 × 3D-TEE(max)- 3.1 × ASDshape + 3. The ASD shape was 0 for round and 1 for oval ASDs. A second model was BS = 4.5 × ASDarea + 11.5. The ASD shape is accurately estimated by 3D-TEE and influences the relationship between echocardiographic measurements and BS. The ASD shape, its maximal diameter and the area assessed by 3D-TEE may be sufficient to determine the device size without BS in children. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Demonstration of infective endocarditis by cardiac CT and transoesophageal echocardiography: comparison with intra-operative findings.

    PubMed

    Koo, Hyun Jung; Yang, Dong Hyun; Kang, Joon-Won; Lee, Joo Yeon; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae-Won; Lim, Tae-Hwan

    2018-02-01

    We aimed to compare imaging findings of infective endocarditis between computed tomography (CT) and transoesophageal echocardiography (TEE) using surgical inspection as a reference standard. Forty-nine patients (aged 54 ± 17 years, 69% men) who underwent pre-operative CT and TEE for infective endocarditis were included. Twelve of these patients had prosthetic valve endocarditis. Imaging findings of infective endocarditis were classified as vegetation, leaflet perforation, abscess/pseudoaneurysm, and paravalvular leakage. Diagnostic performances of CT and TEE were evaluated using surgical inspection as a reference standard. Interobserver agreements for CT findings were obtained using Cohen's κ test. The detection rates of infective endocarditis per patient with CT and TEE were 93.9% (46/49) and 95.9% (47/49), respectively. In per-imaging analysis, the sensitivities of CT and TEE were not significantly different for both native and prosthetic valve infective endocarditis (sensitivity: vegetation, 100% in TEE and 90.9% in CT; leaflet perforation, 87.5% in TEE and 50.0% in CT; abscess/pseudoaneurysm, 40.0% in TEE and 60.0% in CT; paravalvular leakage, 100% in TEE and 50.0% in CT). Interobserver agreements for CT findings were substantial or excellent (0.79-0.88). Cardiac CT can accurately demonstrate infective endocarditis in pre-operative patients with a similar diagnostic accuracy to TEE. The interobserver agreements for the CT findings of infective endocarditis were excellent. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  14. Real-time three-dimensional transesophageal echocardiography in the assessment of mechanical prosthetic mitral valve ring thrombosis.

    PubMed

    Ozkan, Mehmet; Gürsoy, Ozan Mustafa; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Cakal, Beytullah; Karakoyun, Süleyman; Kalçık, Macit; Kahveci, Gökhan; Duran, Nilüfer Ekşi; Yıldız, Mustafa; Cevik, Cihan

    2013-10-01

    Although 2-dimensional (2D) transesophageal echocardiography (TEE) is the gold standard for the diagnosis of prosthetic valve thrombosis, nonobstructive clots located on mitral valve rings can be missed. Real-time 3-dimensional (3D) TEE has incremental value in the visualization of mitral prosthesis. The aim of this study was to investigate the utility of real-time 3D TEE in the diagnosis of mitral prosthetic ring thrombosis. The clinical outcomes of these patients in relation to real-time 3D transesophageal echocardiographic findings were analyzed. Of 1,263 patients who underwent echocardiographic studies, 174 patients (37 men, 137 women) with mitral ring thrombosis detected by real-time 3D TEE constituted the main study population. Patients were followed prospectively on oral anticoagulation for 25 ± 7 months. Eighty-nine patients (51%) had thrombi that were missed on 2D TEE and depicted only on real-time 3D TEE. The remaining cases were partially visualized with 2D TEE but completely visualized with real-time 3D TEE. Thirty-seven patients (21%) had thromboembolism. The mean thickness of the ring thrombosis in patients with thromboembolism was greater than that in patients without thromboembolism (3.8 ± 0.9 vs 2.8 ± 0.7 mm, p <0.001). One hundred fifty-five patients (89%) underwent real-time 3D TEE during follow-up. There were no thrombi in 39 patients (25%); 45 (29%) had regression of thrombi, and there was no change in thrombus size in 68 patients (44%). Thrombus size increased in 3 patients (2%). Thrombosis was confirmed surgically and histopathologically in 12 patients (7%). In conclusion, real-time 3D TEE can detect prosthetic mitral ring thrombosis that could be missed on 2D TEE and cause thromboembolic events. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Comparison of total energy expenditure between school- and summer-months

    PubMed Central

    Zinkel, Sarah R. J.; Moe, Martin; Stern, Elizabeth A.; Hubbard, Van S.; Yanovski, Susan Z.; Yanovski, Jack A.; Schoeller, Dale A.

    2012-01-01

    Objective Recent data reports that youth experience greater weight gain during summer than during school months. We tested the hypothesis that a difference in total energy expenditure (TEE) between school and summer months exists and may contribute to summer weight gain. Subjects and Methods A secondary analysis was performed on cross-sectional TEE data from school-age, sedentary African American and Caucasian youth based in or near the District of Columbia who were at-risk for adult obesity because they had BMI≥85th percentile or had overweight parents. TEE was estimated from 18-O and deuterium measurements during 1-week intervals using urine samples collected after ingestion of doubly-labeled water. Differences in summer and school time TEE were assessed using ANCOVA. The data were adjusted for fat-free mass as determined by deuterium dilution to adjust for the effect of body size on TEE. Results Data were collected from 162 youth (average age 10±2 years, BMI 28±8 kg/m2, and BMI z-score 1.96+0.96). Of these, 96 youth had TEE measured during the school year (September – June); 66 different youths had TEE measured during summer months (June – August). After adjustment for fat-free mass, average summertime TEE was 2450±270 kcal/day and average school-time TEE was 2510±350 kcal/day (p=0.26). Conclusion No difference in TEE was detected between the school year and the summer months. These data suggest that seasonal differences in youth weight gain are not necessarily due to differences in energy expenditures. PMID:23637099

  16. Generative Retrieval Improves Learning and Retention of Cardiac Anatomy Using Transesophageal Echocardiography.

    PubMed

    Kleiman, Amanda M; Forkin, Katherine T; Bechtel, Allison J; Collins, Stephen R; Ma, Jennie Z; Nemergut, Edward C; Huffmyer, Julie L

    2017-05-01

    Transesophageal echocardiography (TEE) is a valuable monitor for patients undergoing cardiac and noncardiac surgery as it allows for evaluation of cardiovascular compromise in the perioperative period. It is challenging for anesthesiology residents and medical students to learn to use and interpret TEE in the clinical environment. A critical component of learning to use and interpret TEE is a strong grasp of normal cardiovascular ultrasound anatomy. Fifteen fourth-year medical students and 15 post-graduate year (PGY) 1 and 2 anesthesiology residents without prior training in cardiac anesthesia or TEE viewed normal cardiovascular anatomy TEE video clips; participants were randomized to learning cardiac anatomy in generative retrieval (GR) and standard practice (SP) groups. GR participants were required to verbally identify each unlabeled cardiac anatomical structure within 10 seconds of the TEE video appearing on the screen. Then a correctly labeled TEE video clip was shown to the GR participant for 5 more seconds. SP participants viewed the same TEE video clips as GR but there was no requirement for SP participants to generate an answer; for the SP group, each TEE video image was labeled with the correctly identified anatomical structure for the 15 second period. All participants were tested for intermediate (1 week) and late (1 month) retention of normal TEE cardiovascular anatomy. Improvement of intermediate and late retention of TEE cardiovascular anatomy was evaluated using a linear mixed effects model with random intercepts and random slopes. There was no statistically significant difference in baseline score between GR (49% ± 11) and SP (50% ± 12), with mean difference (95% CI) -1.1% (-9.5, 7.3%). At 1 week following the educational intervention, GR (90% ± 5) performed significantly better than SP (82% ± 11), with mean difference (95% CI) 8.1% (1.9, 14.2%); P = .012. This significant increase in scores persisted in the late posttest session at one month

  17. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.

    PubMed

    Kretzschmar, Daniel; Lauten, Alexander; Goebel, Bjoern; Doenst, Torsten; Poerner, Tudor C; Ferrari, Markus; Figulla, Hans R; Hamadanchi, Ali

    2016-03-01

    The assessment of aortic annular size is critical, and inappropriate sizing is thought to be a main reason of paravalvular aortic regurgitation. Multidetector computed tomograph is associated with the risk of contrast nephropathy. For optimal evaluation of the complex structure of the aortic annulus, three-dimensional (3D)-methods should be used. We therefore sought to determine the value of 3D-transoesophageal echocardiography (3D-TEE) for appropriate sizing. Hundred and one patients (mean age 81·4 years) with symptomatic aortic valve stenosis (AS) and high surgical risk profile (mean log. EuroScore 28·8%) being scheduled for transcatheter aortic valve implantation (TAVI) were included. 2D- and 3D-TEE were performed before the procedure to evaluate the aortic annulus diameter. Maximum, minimum and mean (max diameter + min diameter/2) annulus diameters were 24·7, 23·1 and 23. 9 mm in 3D-TEE and compared to 22·6 mm in 2D-TEE (P<0·001; 0·07; <0·001). The interobserver variability for 3D-TEE was low with a mean difference of 0·18 mm compared to 2D-TEE with 0·59 mm. The application of 3D-TEE caused a change of prosthesis size selection in 40% of patients compared to 2D-TEE. In this study, we implanted three different types of catheter-mounted valves (Edwards-SAPIEN(™) XT valve, CoreValve(™) and JenaValve(™) ). Final angiography confirmed valve competence (mild insufficiency) in 91%, and there was no aortic regurgitation greater than moderate in the follow-up echocardiographic evaluation. Assessment of aortic annulus dimensions for TAVI size selection can safely be performed with 3D-TEE only. Based on our results with significantly higher annulus diameter compared to 2D-TEE, we recommend 3D-TEE to reduce prosthesis undersizing. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    PubMed

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P < 0.0001). However, following endoscopy, patients reported a significantly better experience with TEE compared with standard endoscopy (7.05 ± 0.49 vs. 4.35 ± 0.53; P = 0.0006), with 60 % preferring TEE and 25 % preferring sedated standard endoscopy. In this study, TEE had equal accuracy for an endoscopic diagnosis of Barrett's esophagus compared with standard endoscopy, at the expense of reduced image quality and a lower yield of intestinal metaplasia on biopsy. TEE was better tolerated and preferred by patients. Hence, TEE needs further evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Total energy expenditure in adults with cerebral palsy as assessed by doubly labeled water.

    PubMed

    Johnson, R K; Hildreth, H G; Contompasis, S H; Goran, M I

    1997-09-01

    To characterize total energy expenditure (TEE) in free-living adults with cerebral palsy (CP) using the doubly labeled water technique, and to determine those physiologic variables and characteristics of CP that were markers of TEE in adults with CP. TEE was measured using the doubly labeled water technique in 30 free-living adults with CP (12 women, 18 men). To determine the best markers of TEE, the following factors were examined: CP status, resting metabolic rate (RMR), anthropometric characteristics and body composition by means of dual-energy x-ray absorptiometry (DXA) and skinfold thickness measurements, energy cost of leisure-time activities, and oral-motor impairment. Means +/- standard deviations, t tests, Pearson product-moment correlation coefficients, Spearman rank correlation coefficients, chi 2, stepwise multiple-correlation regression analysis, and analysis of covariance were used to examine the relationships among variables of interest. TEE was highly variable in the sample (mean = 2,455 +/- 622 kcal/day for men and 1,986 +/- 363 kcal/day for women). Stepwise regression analysis showed that TEE was best predicted in the sample by RMR, percentage body fat determined by DXA, ambulation status, and sex (multiple R = .68, P = .003). When practical, easily measured variables were used, TEE was best predicted by height, ambulation status, percentage body fat by skinfold thickness measurements, and sex (multiple R = .61, P. = 018). The contribution of energy expended in physical activity to TEE was significantly higher in the ambulatory subjects than the nonambulatory subjects (25% vs 16%, respectively; P = .009). The high degree of variability in TEE, largely attributable to high interindividual variation in energy expended in physical activity, makes it difficult to provide general guidelines for energy requirements for adults with CP. Because ambulation status was an important predictor of TEE, it must be accounted for in estimating energy requirements

  20. Diagnosis of malignancy of adult mediastinal tumors by conventional and transesophageal echocardiography.

    PubMed

    Zhou, Wei-Wei; Wang, Hong-Wei; Liu, Nan-Nan; Li, Jing-Jing; Yuan, Wei; Zhao, Rui; Xiang, Liang-Bi; Qi, Miao

    2015-04-20

    Transesophageal echocardiography (TEE) is a well-established method for detecting and diagnosing heart tumors. In contrast, its role in assessing the presence, growth and evidence of malignant tumors originating from mediastinal sites remains unclear. The aim of this study was to compare the diagnostic impact of TEE and transthoracic echocardiography (TTE) for determining the localization, growth and malignancy of adult mediastinal tumors (MTs). In a prospective and investigator-blinded study, we evaluated 144 consecutive patients with MT lesions to assess the diagnostic impact of TEE and TTE for detecting the presence of tumors spreading both inside and outside of the heart and for determining infiltration and invasion using pathological examination results as a reference. All tumor lesions were diagnosed and carefully evaluated by biopsy. Biopsy revealed malignant tumors in 79 patients and benign tumors in 65 patients. When compared to histological findings, TEE predicted malignancy from the presence of tumors spreading both inside and outside of the heart and from infiltration and invasion in 49/79 patients (62.0%). TTE predicted malignancy in only 8/79 patients (10.1%, P < 0.005). TEE visualized tumor lesions in 130 patients (90.3%) while the TTE visualized tumor lesions in 110 patients (76.4%) and was less effective at detecting MT lesions (P < 0.001). TTE and TEE could detect anterior MTs and adequately verified MTs (P > 0.05); TEE detected medium MTs better than TTE (P < 0.001). TEE is effective and superior to TTE for predicting the localization and growth of MTs as well as for accessing evidence of tumor malignancy. TTE and TEE were able to detect anterior MTs; TEE was able to detect medium MT better than TTE.

  1. Diagnosis of Malignancy of Adult Mediastinal Tumors by Conventional and Transesophageal Echocardiography

    PubMed Central

    Zhou, Wei-Wei; Wang, Hong-Wei; Liu, Nan-Nan; Li, Jing-Jing; Yuan, Wei; Zhao, Rui; Xiang, Liang-Bi; Qi, Miao

    2015-01-01

    Background: Transesophageal echocardiography (TEE) is a well-established method for detecting and diagnosing heart tumors. In contrast, its role in assessing the presence, growth and evidence of malignant tumors originating from mediastinal sites remains unclear. The aim of this study was to compare the diagnostic impact of TEE and transthoracic echocardiography (TTE) for determining the localization, growth and malignancy of adult mediastinal tumors (MTs). Methods: In a prospective and investigator-blinded study, we evaluated 144 consecutive patients with MT lesions to assess the diagnostic impact of TEE and TTE for detecting the presence of tumors spreading both inside and outside of the heart and for determining infiltration and invasion using pathological examination results as a reference. Results: All tumor lesions were diagnosed and carefully evaluated by biopsy. Biopsy revealed malignant tumors in 79 patients and benign tumors in 65 patients. When compared to histological findings, TEE predicted malignancy from the presence of tumors spreading both inside and outside of the heart and from infiltration and invasion in 49/79 patients (62.0%). TTE predicted malignancy in only 8/79 patients (10.1%, P < 0.005). TEE visualized tumor lesions in 130 patients (90.3%) while the TTE visualized tumor lesions in 110 patients (76.4%) and was less effective at detecting MT lesions (P < 0.001). TTE and TEE could detect anterior MTs and adequately verified MTs (P > 0.05); TEE detected medium MTs better than TTE (P < 0.001). Conclusions: TEE is effective and superior to TTE for predicting the localization and growth of MTs as well as for accessing evidence of tumor malignancy. TTE and TEE were able to detect anterior MTs; TEE was able to detect medium MT better than TTE. PMID:25881598

  2. Accuracy of a combined heart rate and motion sensor for assessing energy expenditure in free-living adults during a double-blind crossover caffeine trial using doubly labeled water as the reference method.

    PubMed

    Silva, A M; Santos, D A; Matias, C N; Júdice, P B; Magalhães, J P; Ekelund, U; Sardinha, L B

    2015-01-01

    A combined heart rate (HR) and motion sensor (Actiheart) has been proposed as an accurate method for assessing total energy expenditure (TEE) and physical activity energy expenditure (PAEE). However, the extent to which factors such as caffeine may affect the accuracy by which the estimated HR-related PAEE contribution will affect TEE and PAEE estimates is unknown. Therefore, we examined the validity of Actiheart in estimating TEE and PAEE in free-living adults under a caffeine trial compared with doubly labeled water (DLW) as reference criterion. Using a double-blind crossover trial (Clinicaltrials.gov ID: #NCT01477294) with two conditions (4-day each with a 3-day-washout period), randomly ordered as caffeine (5 mg/kg per day) and placebo (malt-dextrine) intake, TEE was measured by DLW in 17 physically active men (20-38 years) who were non-caffeine users. In each condition, resting energy expenditure (REE) was assessed by indirect calorimetry and PAEE was calculated as (TEE-(REE+0.1 TEE)). Simultaneously, PAEE and TEE were estimated by Actiheart using an individual calibration (ACC+HRstep). Under caffeine, ACC+HRstep explained 76 and 64% of TEE and PAEE from DLW, respectively; corresponding results for the placebo condition were 82 and 66%. No mean bias was found between ACC+HRstep and DLW for TEE (caffeine:-468 kJ per day; placebo:-407 kJ per day), although PAEE was slightly underestimated (caffeine:-856 kJ per day; placebo:-1147 kJ per day). Similar limits of agreement were observed in both conditions ranging from -2066 to 3002 and from -3488 to 1776 kJ per day for TEE and PAEE, respectively. Regardless of caffeine intake, the combined HR and motion sensor is valid for estimating free-living energy expenditure in a group of healthy men but is less accurate for an individual assessment.

  3. Manual Skill Acquisition During Transesophageal Echocardiography Simulator Training of Cardiology Fellows: A Kinematic Assessment.

    PubMed

    Matyal, Robina; Montealegre-Gallegos, Mario; Mitchell, John D; Kim, Han; Bergman, Remco; Hawthorne, Katie M; O'Halloran, David; Wong, Vanessa; Hess, Phillip E; Mahmood, Feroze

    2015-12-01

    To investigate whether a transesophageal echocardiography (TEE) simulator with motion analysis can be used to impart proficiency in TEE in an integrated curriculum-based model. A prospective cohort study. A tertiary-care university hospital. TEE-naïve cardiology fellows. Participants underwent an 8-session multimodal TEE training program. Manual skills were assessed at the end of sessions 2 and 8 using motion analysis of the TEE simulator's probe. At the end of the course, participants performed an intraoperative TEE; their examinations were video captured, and a blinded investigator evaluated the total time and image transitions needed for each view. Results are reported as mean±standard deviation, or median (interquartile range) where appropriate. Eleven fellows completed the knowledge and kinematic portions of the study. Five participants were excluded from the evaluation in the clinical setting because of interim exposure to TEE or having participated in a TEE rotation after the training course. An increase of 12.95% in post-test knowledge scores was observed. From the start to the end of the course, there was a significant reduction (p<0.001 for all) in the number of probe. During clinical performance evaluation, trainees were able to obtain all the required echocardiographic views unassisted but required a longer time and had more probe transitions when compared with an expert. A curriculum-based approach to TEE training for cardiology fellows can be complemented with kinematic analyses to objectify acquisition of manual skills during simulator-based training. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    PubMed

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  5. ADAM-C score: New risk score for predicting diagnostic yield of transesophageal echocardiography after cerebral ischemia.

    PubMed

    Charbonnel, Clément; Jego, Christophe; Jourda, François; Vinsonneau, Ulric; Garçon, Philippe; Turlotte, Guillaume; Rivière, Jean François; Maurin, Marion; Lubret, Rémy; Meimoun, Patrick; Akret, Chrystelle; Cournot, Maxime; Sokic, Charles; Michel, Laurent; Lescure, Maryse; Kenizou, David; Melay, Marie; Fayard, Maxime; Gallet, Bruno; Fouche, Rémi; Janin-Manificat, Luc; Dijoux, Nicolas; Martin, Anne Céline; Tho-Agostini, Aurélia; Mann, Hubert; Ricard, Cécile; Pico, Fernando; Georges, Jean Louis; Belle, Loïc; Jourdain, Patrick

    2018-05-14

    The clinical utility of transesophageal echocardiography (TEE) after brain ischemia (BI) remains a matter of debate. We aimed to evaluate the clinical impact of TEE and to build a score that could help physicians to identify which patients should better benefit from TEE. This prospective, multicenter, observational study included patients over 18 years old, hospitalized for BI. TEE findings were judged discriminant if the results showed important information leading to major changes in the management of patients. Most patients with patent foramen ovale were excluded. Variables independently associated with a discriminant TEE were used to build the prediction model. Of the entire population (1479 patients), 255 patients (17%) were classified in the discriminant TEE group. Five parameters were selected as predictors of a discriminant TEE. Accordingly, the ADAM-C score could be calculated as follows: Score = 4 (if age ≥60) + 2 (if diabetes) + 2 (if aortic stenosis from any degrees) + 1 (if multi-territory stroke) + 2 (if history of coronary artery disease). At a threshold lower than 3, the sensitivity, specificity, positive predictive value, and negative predictive value (NPV) of detecting discriminant TEE were 88% (95% CI 85-90), 44% (95% CI 41-47), 21% (95% CI 19-27), and 95% (95% CI 94-97), respectively. A simple score based on clinical and transthoracic echocardiographic parameters can help physicians to identify patients who might not benefit from TEE. Indeed, a score lower than 3 has an interesting NPV of 95% (95% CI 94-97). © 2018 Wiley Periodicals, Inc.

  6. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    PubMed

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  7. Integration of trans-esophageal echocardiography with magnetic tracking technology for cardiac interventions

    NASA Astrophysics Data System (ADS)

    Moore, John T.; Wiles, Andrew D.; Wedlake, Chris; Bainbridge, Daniel; Kiaii, Bob; Trejos, Ana Luisa; Patel, Rajni; Peters, Terry M.

    2010-02-01

    Trans-esophageal echocardiography (TEE) is a standard component of patient monitoring during most cardiac surgeries. In recent years magnetic tracking systems (MTS) have become sufficiently robust to function effectively in appropriately structured operating room environments. The ability to track a conventional multiplanar 2D TEE transducer in 3D space offers incredible potential by greatly expanding the cumulative field of view of cardiac anatomy beyond the limited field of view provided by 2D and 3D TEE technology. However, there is currently no TEE probe manufactured with MTS technology embedded in the transducer, which means sensors must be attached to the outer surface of the TEE. This leads to potential safety issues for patients, as well as potential damage to the sensor during procedures. This paper presents a standard 2D TEE probe fully integrated with MTS technology. The system is evaluated in an environment free of magnetic and electromagnetic disturbances, as well as a clinical operating room in the presence of a da Vinci robotic system. Our first integrated TEE device is currently being used in animal studies for virtual reality-enhanced ultrasound guidance of intracardiac surgeries, while the "second generation" TEE is in use in a clinical operating room as part of a project to measure perioperative heart shift and optimal port placement for robotic cardiac surgery. We demonstrate excellent system accuracy for both applications.

  8. A modification of the trans-oesophageal echocardiography protocol can reduce post-operative dysphagia following cardiac surgery.

    PubMed

    Chin, J-H; Lee, E-H; Choi, D-K; Choi, I-C

    2011-01-01

    Use of intra-operative trans-oesophageal echocardiography (TEE) is an independent risk factor for post-operative dysphagia. This study investigated whether modifying the TEE probe-placement protocol could reduce the incidence of post-operative dysphagia. In group I (n = 100), the TEE probe was inserted after anaesthetic induction and remained in place until the completion of surgery. In group II (n = 100), the TEE probe was inserted after anaesthetic induction, the heart was examined, then the probe was removed. The probe was inserted again before weaning from cardiopulmonary bypass and then immediately removed after examination. The incidence of dysphagia was significantly higher in group I than in group II patients (51.1% versus 28.6%). Multivariate regression analysis showed that the length of time that the TEE probe was in the oesophagus was an independent predictor of dysphagia. Modification of the TEE protocol in this way can reduce the incidence of post-operative dysphagia in cardiac surgery patients.

  9. The value of transesophageal echocardiography for embolic strokes of undetermined source

    PubMed Central

    Katsanos, Aristeidis H.; Bhole, Rohini; Frogoudaki, Alexandra; Giannopoulos, Sotirios; Goyal, Nitin; Vrettou, Agathi-Rosa; Ikonomidis, Ignatios; Paraskevaidis, Ioannis; Pappas, Konstantinos; Parissis, John; Kyritsis, Athanassios P.; Alexandrov, Anne W.; Triantafyllou, Nikos; Malkoff, Marc D.; Voumvourakis, Konstantinos; Alexandrov, Andrei V.

    2016-01-01

    Objective: Our aim was to evaluate the diagnostic yield of transesophageal echocardiography (TEE) in consecutive patients with ischemic stroke (IS) fulfilling the diagnostic criteria of embolic strokes of undetermined source (ESUS). Methods: We prospectively evaluated consecutive patients with acute IS satisfying ESUS criteria who underwent in-hospital TEE examination in 3 tertiary care stroke centers during a 12-month period. We also performed a systematic review and meta-analysis estimating the cumulative effect of TEE findings on therapeutic management for secondary stroke prevention among different IS subgroups. Results: We identified 61 patients with ESUS who underwent investigation with TEE (mean age 44 ± 12 years, 49% men, median NIH Stroke Scale score = 5 points [interquartile range: 3–8]). TEE revealed additional findings in 52% (95% confidence interval [CI]: 40%–65%) of the study population. TEE findings changed management (initiation of anticoagulation therapy, administration of IV antibiotic therapy, and patent foramen ovale closure) in 10 (16% [95% CI: 9%–28%]) patients. The pooled rate of reported anticoagulation therapy attributed to abnormal TEE findings among 3,562 acute IS patients included in the meta-analysis (12 studies) was 8.7% (95% CI: 7.3%–10.4%). In subgroup analysis, the rates of initiation of anticoagulation therapy on the basis of TEE investigation did not differ (p = 0.315) among patients with cryptogenic stroke (6.9% [95% CI: 4.9%–9.6%]), ESUS (8.1% [95% CI: 3.4%–18.1%]), and IS (9.4% [95% CI: 7.5%–11.8%]). Conclusions: Abnormal TEE findings may decisively affect the selection of appropriate therapeutic strategy in approximately 1 of 7 patients with ESUS. PMID:27488602

  10. The value of transesophageal echocardiography for embolic strokes of undetermined source.

    PubMed

    Katsanos, Aristeidis H; Bhole, Rohini; Frogoudaki, Alexandra; Giannopoulos, Sotirios; Goyal, Nitin; Vrettou, Agathi-Rosa; Ikonomidis, Ignatios; Paraskevaidis, Ioannis; Pappas, Konstantinos; Parissis, John; Kyritsis, Athanassios P; Alexandrov, Anne W; Triantafyllou, Nikos; Malkoff, Marc D; Voumvourakis, Konstantinos; Alexandrov, Andrei V; Tsivgoulis, Georgios

    2016-09-06

    Our aim was to evaluate the diagnostic yield of transesophageal echocardiography (TEE) in consecutive patients with ischemic stroke (IS) fulfilling the diagnostic criteria of embolic strokes of undetermined source (ESUS). We prospectively evaluated consecutive patients with acute IS satisfying ESUS criteria who underwent in-hospital TEE examination in 3 tertiary care stroke centers during a 12-month period. We also performed a systematic review and meta-analysis estimating the cumulative effect of TEE findings on therapeutic management for secondary stroke prevention among different IS subgroups. We identified 61 patients with ESUS who underwent investigation with TEE (mean age 44 ± 12 years, 49% men, median NIH Stroke Scale score = 5 points [interquartile range: 3-8]). TEE revealed additional findings in 52% (95% confidence interval [CI]: 40%-65%) of the study population. TEE findings changed management (initiation of anticoagulation therapy, administration of IV antibiotic therapy, and patent foramen ovale closure) in 10 (16% [95% CI: 9%-28%]) patients. The pooled rate of reported anticoagulation therapy attributed to abnormal TEE findings among 3,562 acute IS patients included in the meta-analysis (12 studies) was 8.7% (95% CI: 7.3%-10.4%). In subgroup analysis, the rates of initiation of anticoagulation therapy on the basis of TEE investigation did not differ (p = 0.315) among patients with cryptogenic stroke (6.9% [95% CI: 4.9%-9.6%]), ESUS (8.1% [95% CI: 3.4%-18.1%]), and IS (9.4% [95% CI: 7.5%-11.8%]). Abnormal TEE findings may decisively affect the selection of appropriate therapeutic strategy in approximately 1 of 7 patients with ESUS. © 2016 American Academy of Neurology.

  11. Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection.

    PubMed

    Caputi, Luigi; Carriero, Maria Rita; Falcone, Chiara; Parati, Eugenio; Piotti, Patrizia; Materazzo, Carlo; Anzola, Gian Paolo

    2009-01-01

    Patent foramen ovale (PFO) has been investigated in several conditions apart from cryptogenic ischemic stroke. Contrast transesophageal echocardiography (cTEE) is the gold standard for the diagnosis, although it has some known limitations. Contrast transcranial Doppler (cTCD) allows a semiquantitative estimation of right-to-left shunt (RLS) volume. The aims of our study were to confirm the diagnostic accuracy of cTCD in PFO diagnosis and to compare the abilities of cTCD and cTEE to detect a RLS and PFO, respectively, under normal breathing. The latter could represent an important feature for its clinical significance. A total of 100 consecutive patients (59 women and 41 men, age 46 +/- 12 years) were evaluated after stabilized ischemic stroke/transient ischemic attack, migraine, and lacunae, and before neurosurgery in sitting position. All patients undertook cTEE and cTCD, at rest and under Valsalva maneuver (VM). cTEE under VM was the reference standard. A categorization of patients and a semiquantitative cTCD classification were proposed. In all, 63 of 100 patients had PFO diagnosed by cTEE. A general concordance of up to 90% between both techniques was found. cTCD sensitivity and specificity were 96.8% and 78.4%, respectively. In 17 of 100 patients with cTEE-proven PFO under VM, cTCD and cTEE detected RLS at rest in 75% (95% confidence interval [CI] 62%-85%) and 48% (95% CI 35%-61%) of cases, respectively (P < .001). cTEE disclosed RLS at rest in about 71% (95% CI 9%-42%) of cTCDs showing a "shower-curtain" pattern and only in about 22% (95% CI 52%-85%) of those cTCDs without that pattern. In diagnosing PFO, cTCD has a good accuracy compared with cTEE. To detect a RLS at rest, cTCD appears to be more sensitive than cTEE. The latter resulted positive under normal breathing, mostly in cases of significant RLS at cTCD. Our results point out the impact of cTCD in the evaluation of RLS volume, thus aiding, in association with the anatomic details by cTEE, in the

  12. Kinetics of Supercritical Water Oxidation. SERDP Compliance Technical Thrust Area

    DTIC Science & Technology

    1996-01-01

    main stream velocity ratio (vj/ Vrx ) and jet-to-main stream diameter ratio) were different for the two tees. As a result, the "fast" tee was providing...Opposed-Flow Tee with no Inserts: Organic/Water Oxidant/Water Feed Feed Flow Conditions: vj (cm/s) 20-64 vj/ Vrx = 0.2-0.25 _ Rej =905-2920 To Reactor...Oxidant/Water Feed New Side-Entry Tee with 0.01" ID inserts: Organic/Water Feed Flow Conditions: vi (cm/s) 775-2,500 vj/ Vrx = 7.5-9.3 Rej =5,700-18,000

  13. [Usefullness of transesophageal echocardiography in early detection of coronary spasm].

    PubMed

    Sagara, M; Haraguchi, M; Hamu, Y; Isowaki, S; Yoshimura, N

    1996-04-01

    Intraoperative transesophageal echocardiography (TEE) was performed on a 62-year-old man who underwent abdominal aortic replacement for abdominal aortic aneurysm under general anesthesia combined with epidural anesthesia. Coronary artery spasm occurred after unexpected massive hemorrhage, and TEE showed hypokinesis in the posterior-inferior left ventricular wall. The changes in TEE preceded the ST elevation in the ECG. Bolus infusion of isosorbide dinitrate and continuous infusion of nitroglycerin alleviated these changes. TEE enabled us to detect and evaluate coronary spasm before the appearance of ST changes in ECG.

  14. Energy demand in patients with stroke who are sedated and receiving mechanical ventilation.

    PubMed

    Bardutzky, Juergen; Georgiadis, Dimitrios; Kollmar, Rainer; Schwarz, Stefan; Schwab, Stefan

    2004-02-01

    The purpose of this study was 1) to determine the total energy expenditure (TEE) in patients with acute stroke who are sedated and receiving mechanical ventilation; and 2) to compare the TEE between patients with ischemic and hemorrhagic stroke. Thirty-four consecutive nonseptic patients with stroke requiring sedation and mechanical ventilation were prospectively examined; 13 of the patients had experienced spontaneous intracerebral hemorrhage and 21 cerebral ischemia of the middle cerebral artery territory. The TEE was evaluated using continuous indirect calorimetry during the first 5 days after admission to the intensive care unit. The serum albumin concentration was determined on admission and on Day 5. The TEE varied from 1560 +/- 240 to 1623 +/- 251 kcal/day. A highly significant correlation between the TEE and the basal energy expenditure (BEE), as predicted using the Harris-Benedict equation, was observed in both groups. No significant differences in the TEE were detected between the two groups or among the different study days. A highly significant correlation was found between the TEE and the predicted BEE in patients with acute stroke who have been sedated and have received mechanical ventilation. No significant differences were observed between patients with hemorrhagic and ischemic stroke. Further studies are needed to evaluate the effect of tailored feeding on clinical outcome in these patients.

  15. Murine and Human Tissue-Engineered Esophagus Form from Sufficient Stem/Progenitor Cells and Do Not Require Microdesigned Biomaterials

    PubMed Central

    Spurrier, Ryan Gregory; Speer, Allison L.; Hou, Xiaogang; El-Nachef, Wael N.

    2015-01-01

    Purpose: Tissue-engineered esophagus (TEE) may serve as a therapeutic replacement for absent foregut. Most prior esophagus studies have favored microdesigned biomaterials and yielded epithelial growth alone. None have generated human TEE with mesenchymal components. We hypothesized that sufficient progenitor cells might only require basic support for successful generation of murine and human TEE. Materials and Methods: Esophageal organoid units (EOUs) were isolated from murine or human esophagi and implanted on a polyglycolic acid/poly-l-lactic acid collagen-coated scaffold in adult allogeneic or immune-deficient mice. Alternatively, EOU were cultured for 10 days in vitro prior to implantation. Results: TEE recapitulated all key components of native esophagus with an epithelium and subjacent muscularis. Differentiated suprabasal and proliferative basal layers of esophageal epithelium, muscle, and nerve were identified. Lineage tracing demonstrated that multiple EOU could contribute to the epithelium and mesenchyme of a single TEE. Cultured murine EOU grew as an expanding sphere of proliferative basal cells on a neuromuscular network that demonstrated spontaneous peristalsis in culture. Subsequently, cultured EOU generated TEE. Conclusions: TEE forms after transplantation of mouse and human organ-specific stem/progenitor cells in vivo on a relatively simple biodegradable scaffold. This is a first step toward future human therapies. PMID:25298083

  16. [Clinical research on the application of trans-esophageal echocardiography in monitoring Nuss surgery].

    PubMed

    Mou, Ling; Xu, Bing; Lan, Zhixun

    2015-04-01

    To investigate the validity and safety of trans-esophageal echocardiography (TEE) in monitoring of Nuss surgery. A total of 140 patients with pectus excavatum from Sichuan Provincial People's Hospital underwent Nuss surgery from August, 2011 to Aμgust, 2013. Among them, 72 patients received TEE monitoring while 68 patients didn't. The injury of heart and large vessels by the introducer and Nuss steel bar was observed by intraoperative TEE monitoring under middle-esophageal four chamber view and middle-esophageal aortic short axis view. The operation in all patients had been performed successfully without any severe complications. Satisfactory TEE images were obtained in all patients. The procedure of inserting the inducer and Nuss steel bar behind sternum and steel bar overturn could be seen clearly. No injury in heart and large vessels was detected. Local streak-like hemorrhage in 3 patients was observed under intra-operative TEE screen, but no further new bleeding was found in postoperative TEE examination. The blood was absorbed and couldn't see under trans-thoracic echocardiography in 1 month after the operation. The TEE is a non-invasive monitoring method. It is sensitive to detect the status of the heart and large vessels and can prevent the severe complications due to Nuss surgery.

  17. Comparison of total energy expenditure between school and summer months.

    PubMed

    Zinkel, S R J; Moe, M; Stern, E A; Hubbard, V S; Yanovski, S Z; Yanovski, J A; Schoeller, D A

    2013-10-01

    Childhood obesity has increased 3 to 4 fold. Some children gain excess weight in summer. Total energy expenditure increases almost linearly with fat-free mass. A lower total energy expenditure was not detected in summer. Recent data report that the youth experience greater weight gain during summer than during school months. We tested the hypothesis that a difference in total energy expenditure (TEE) between school and summer months exists and may contribute to summer weight gain. A secondary analysis was performed on cross-sectional TEE data from school-age, sedentary African-American and Caucasian youth based in or near the District of Columbia who were at-risk for adult obesity because they had body mass index (BMI) ≥ 85th percentile or had overweight parents. TEE was estimated from 18-O and deuterium measurements during 1-week intervals using urine samples collected after ingestion of doubly labelled water. Differences in summer- and school-time TEE were assessed using analysis of covariance. The data were adjusted for fat-free mass (FFM) as determined by deuterium dilution to adjust for the effect of body size on TEE. Data were collected from 162 youth (average age 10 ± 2 years, BMI 28 ± 8 kg m(-2) and BMI z-score 1.96 + 0.96). Of these, 96 youth had TEE measured during the school year (September-June); 66 different youths had TEE measured during summer months (June-August). After adjustment for FFM, average summertime TEE was 2450 ± 270 kcal d(-1) and average school-time TEE was 2510 ± 350 kcal d(-1) (P = 0.26). No difference in TEE was detected between the school year and the summer months. These data suggest that seasonal differences in youth weight gain are not necessarily due to differences in energy expenditures. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.

  18. Making a success of providing NHS Health Checks in community pharmacies across the Tees Valley: a qualitative study

    PubMed Central

    2011-01-01

    Background In England and Wales, the Department of Health introduced a primary prevention programme, NHS Health Checks, to provide screening for cardiovascular risk amongst people aged 40-74. The aim of this programme is to offer treatment and advice to those identified with an increased risk of cardiovascular diseases (CVD). The North East of England has some of the highest rates of CVD in the UK and prevention is therefore a priority. NHS Tees funded this programme of work under the local branding of Healthy Heart Checks (HHC). These were initially implemented principally through GP practices from October 2008 but, in order to mitigate the possibility that some hard to reach communities would be reluctant to engage with some primary care settings, plans were also developed to deliver the programme through workplace settings and through community pharmacies. This paper reports specifically on the findings from the evaluation in respect of the setting up of HHCs in community pharmacies and aims to offer some lessons for other service settings where this option is seen as a way of providing low threshold services which will minimise inequalities in intervention uptake. Methods In assessing the community pharmacy component of HHCs, a selection of staff having direct involvement in the process was invited to take part in the evaluation. Interviews were carried out with representatives from community pharmacy, staff members from the commissioning Primary Care Trusts and with Local Pharmaceutical Committee members. Results Evaluation and analysis identified challenges which should be anticipated and addressed in initiating HHC in community pharmacies. These have been categorised into four main themes for discussion in this paper: (1) establishing and maintaining pharmacy Healthy Heart Checks, (2) overcoming IT barriers, (3) developing confident, competent staff and (4) ensuring volume and through flow in pharmacy. Conclusions Delivering NHS health checks through

  19. The value of real-time three-dimensional transesophageal echocardiography in the assessment of paravalvular leak origin following prosthetic mitral valve replacement.

    PubMed

    Yildiz, Mustafa; Duran, Nilüfer Ekşi; Gökdeniz, Tayyar; Kaya, Hasan; Ozkan, Mehmet

    2009-09-01

    Two-dimensional (2D) echocardiographic approaches are not sufficient to determine the origin of paravalvular leak (PVL) that occurs after prosthetic mitral valve replacement (MVR). In this study, we investigated the role of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in detecting the origin and size of PVL occurring after prosthetic MVR. The study included 13 patients (7 females; 6 males; mean age 56+/-10 years; range 37 to 71 years) who developed PVL within a mean of 8.3+/-3.8 years following mechanical prosthetic MVR. Nine patients (69.2%) had atrial fibrillation, and four patients (30.8%) had normal sinus rhythm. Four patients (30.8%) had hemolysis. Paravalvular leak was mild, moderate, and severe in two, six, and five patients, respectively. Real-time 3D TEE was performed using a 3D matrix-array TEE transducer immediately after detection of PVL on 2D TEE examination. Localization of PVL was made using a clock-wise format in relation to the aortic valve and the size of dehiscence was measured. The mean PVL width measured by 2D TEE was 3.00+/-0.92 mm. The mean length of dehiscence was 13.6+/-8.8 mm, and the mean width was 3.88+/-2.04 mm on RT-3D TEE. The PVLs were mainly localized in the posterior and anterior annular positions between 12 to 03 hours (n=7) and 06 to 09 hours (n=3) on RT-3D TEE, respectively, which corresponded to the posteromedial or anterolateral sectors of the posterior annulus. Considering that only the width of the PVL defect can be assessed by 2D TEE, delineation by RT-3D TEE includes the localization of PVL together with the length and width of the defect.

  20. Aortic valve type and calcification as assessed by transthoracic and transoesophageal echocardiography.

    PubMed

    Yousry, Mohamed; Rickenlund, Anette; Petrini, Johan; Jenner, Jonas; Liska, Jan; Eriksson, Per; Franco-Cereceda, Anders; Eriksson, Maria J; Caidahl, Kenneth

    2015-07-01

    Aortic valve calcification (AVC) may predict poor outcome. Bicuspid aortic valve (BAV) leads to several haemodynamic changes accelerating the progress of aortic valve (AV) disease. To compare the diagnostic accuracy of transoesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in the assessment of aortic valve phenotype and degree of AVC, with intra-operative evaluation as a reference. We examined 169 patients (median age 65 years, 51 women) without significant coronary artery disease undergoing AV and/or aortic root surgery. TTE was performed within a week prior to surgery and TEE at the time of surgery. Compared with surgical AVC assessment, visual evaluation using a 5-grade scoring system and real-time images showed a higher correlation (TTE r = 0·83 and TEE r = 0·82) than visual (TTE r = 0·64 and TEE 0·63) or grey scale mean (GSMn) (TTE r = 0·63 and TEE r = 0·52) assessment of end-diastolic still frames. AVC assessment using real-time images showed high intraclass correlation coefficients (TTE 0·94 and TEE 0·93). With regard to BAV, TEE was superior to TTE with a higher interobserver agreement, sensitivity and specificity (0·86, 92% and 94% versus 0·57, 77% and 82%, respectively). Semi-quantitative AVC assessment of real-time cine loops from both TEE and TTE correlated well with intra-operative evaluation of AVC. Applying a predefined scoring system for AVC evaluation assures a high interobserver correlation. TEE was superior to TTE for evaluation of valve phenotype and should be considered when a diagnosis of BAV is clinically important. © 2014 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  1. Daily energy expenditure by five-year-old children, measured by doubly labeled water.

    PubMed

    Fontvieille, A M; Harper, I T; Ferraro, R T; Spraul, M; Ravussin, E

    1993-08-01

    Current recommendations for daily energy requirements in 5-year-old children (90 kcal/kg per day) are based on energy intake associated with normal growth. It is not known, however, how these recommendations compare with total free-living energy expenditure (TEE) and how much of TEE is related to physical activity. The TEE and the resting metabolic rate (RMR) were measured in 28 white children, aged 5 years (15 boys, 13 girls; mean (+/- SD) weight 20.1 +/- 3.4 kg; height 113 +/- 6 cm; fat 20% +/- 5%). The TEE was calculated during a 7-day period from urinary elimination rates of deuterium (2H) and heavy oxygen (18O) by using a modification of the two-point slope-intercept method; RMR was measured by a ventilated-hood indirect calorimeter. Physical activity indexes were also collected from questionnaires completed by the parents. Measured TEE was considerably lower than the recommended dietary allowances (1370 +/- 222 kcal/day vs 1807 +/- 310 kcal/day; p < 0.0001), whereas measured RMR was slightly higher than predicted RMR (1001 +/- 119 kcal/day vs 952 +/- 78 kcal/day; p < 0.001). The energy cost of physical activity accounted for only 16% +/- 7% of TEE. An index of activity, assessed as the difference between the measured TEE and the predicted TEE, correlated positively with past-year sport-leisure activity assessed by questionnaire (r = 0.40; p < 0.05). We conclude that measured TEE in 5-year-old children yields lower values (approximately 400 kcal/day) than current estimates. A minute part of this difference (20 to 30 kcal/day) is related to the changes in energy stores during growth, but most seems due to lower-than-expected levels of physical activity. This might be related to increased television viewing, which replaces activities requiring energy.

  2. Simultaneous Validation of Seven Physical Activity Questionnaires Used in Japanese Cohorts for Estimating Energy Expenditure: A Doubly Labeled Water Study.

    PubMed

    Sasai, Hiroyuki; Nakata, Yoshio; Murakami, Haruka; Kawakami, Ryoko; Nakae, Satoshi; Tanaka, Shigeho; Ishikawa-Takata, Kazuko; Yamada, Yosuke; Miyachi, Motohiko

    2018-04-28

    Physical activity questionnaires (PAQs) used in large-scale Japanese cohorts have rarely been simultaneously validated against the gold standard doubly labeled water (DLW) method. This study examined the validity of seven PAQs used in Japan for estimating energy expenditure against the DLW method. Twenty healthy Japanese adults (9 men; mean age, 32.4 [standard deviation {SD}, 9.4] years, mainly researchers and students) participated in this study. Fifteen-day daily total energy expenditure (TEE) and basal metabolic rate (BMR) were measured using the DLW method and a metabolic chamber, respectively. Activity energy expenditure (AEE) was calculated as TEE - BMR - 0.1 × TEE. Seven PAQs were self-administered to estimate TEE and AEE. The mean measured values of TEE and AEE were 2,294 (SD, 318) kcal/day and 721 (SD, 161) kcal/day, respectively. All of the PAQs indicated moderate-to-strong correlations with the DLW method in TEE (rho = 0.57-0.84). Two PAQs (Japan Public Health Center Study [JPHC]-PAQ Short and JPHC-PAQ Long) showed significant equivalence in TEE and moderate intra-class correlation coefficients (ICC). None of the PAQs showed significantly equivalent AEE estimates, with differences ranging from -547 to 77 kcal/day. Correlations and ICCs in AEE were mostly weak or fair (rho = 0.02-0.54, and ICC = 0.00-0.44). Only JPHC-PAQ Short provided significant and fair agreement with the DLW method. TEE estimated by the PAQs showed moderate or strong correlations with the results of DLW. Two PAQs showed equivalent TEE and moderate agreement. None of the PAQs showed equivalent AEE estimation to the gold standard, with weak-to-fair correlations and agreements. Further studies with larger sample sizes are needed to confirm these findings.

  3. Transoesophageal echocardiography in the dog.

    PubMed

    Domenech, Oriol; Oliveira, Pedro

    2013-11-01

    Transoesophageal echocardiography (TEE) allows imaging of the heart through the oesophagus using a special transducer mounted on a modified endoscope. The proximity to the heart and minimal intervening structures enables the acquisition of high-resolution images that are consistently superior to routine transthoracic echocardiography and optimal imaging of the heart base anatomy and related structures. TEE provides high-quality real-time imaging free of ionizing radiation, making it an ideal instrument not only for diagnostic purposes, but also for monitoring surgical or minimally invasive cardiac procedures, non-cardiac procedures and critical cases in the intensive care unit. In human medicine, TEE is routinely used in these settings. In veterinary medicine, TEE is increasingly used in referral centres, especially for perioperative assessment and guidance of catheter-based cardiovascular procedures, such as patent ductus arteriosus, balloon valvuloplasty, and atrial and ventricular septal defect occlusion with vascular devices. TEE can also aid in heartworm retrieval procedures. The purpose of this paper is to review the current uses of TEE in veterinary medicine, focusing on technique, indications and complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Lycopersicon esculentum Extract Enhances Cognitive Function and Hippocampal Neurogenesis in Aged Mice

    PubMed Central

    Bae, Jung-Soo; Han, Mira; Shin, Hee Soon; Shon, Dong-Hwa; Lee, Soon-Tae; Shin, Chang-Yup; Lee, Yuri; Lee, Dong Hun; Chung, Jin Ho

    2016-01-01

    A decrease in adult neurogenesis is associated with the aging process, and this decrease is closely related to memory impairment. Tomato (Lycopersicon esculentum) is a fruit with diverse bioactive nutrients that is consumed worldwide. In this study, we investigated the cognition-enhancing effect of tomato ethanolic extracts (TEE) in aged mice. Six weeks of oral TEE administration in 12-month-old aged mice significantly increased their exploration time of novel objects when compared to vehicle-treated mice. The TEE supplement increased doublecortin (DCX)-positive cells and postsynaptic density-95 (PSD95) expression in mice hippocampus. Moreover, we found an increased expression of brain-derived neurotrophic factor (BDNF) and subsequently-activated extracellular-signal-regulated kinase (ERK)/cAMP response element binding (CREB) signaling pathway in the TEE-supplemented mice hippocampus. In conclusion, the oral administration of TEE exhibits a cognition-enhancing effect, and the putative underlying mechanism is the induction of BDNF signaling-mediated proliferation and synapse formation in the hippocampus. These findings indicate that TEE could be a candidate for treatment of age-related memory impairment and neurodegenerative disorders. PMID:27792185

  5. Lycopersicon esculentum Extract Enhances Cognitive Function and Hippocampal Neurogenesis in Aged Mice.

    PubMed

    Bae, Jung-Soo; Han, Mira; Shin, Hee Soon; Shon, Dong-Hwa; Lee, Soon-Tae; Shin, Chang-Yup; Lee, Yuri; Lee, Dong Hun; Chung, Jin Ho

    2016-10-26

    A decrease in adult neurogenesis is associated with the aging process, and this decrease is closely related to memory impairment. Tomato ( Lycopersicon esculentum ) is a fruit with diverse bioactive nutrients that is consumed worldwide. In this study, we investigated the cognition-enhancing effect of tomato ethanolic extracts (TEE) in aged mice. Six weeks of oral TEE administration in 12-month-old aged mice significantly increased their exploration time of novel objects when compared to vehicle-treated mice. The TEE supplement increased doublecortin (DCX)-positive cells and postsynaptic density-95 (PSD95) expression in mice hippocampus. Moreover, we found an increased expression of brain-derived neurotrophic factor (BDNF) and subsequently-activated extracellular-signal-regulated kinase (ERK)/cAMP response element binding (CREB) signaling pathway in the TEE-supplemented mice hippocampus. In conclusion, the oral administration of TEE exhibits a cognition-enhancing effect, and the putative underlying mechanism is the induction of BDNF signaling-mediated proliferation and synapse formation in the hippocampus. These findings indicate that TEE could be a candidate for treatment of age-related memory impairment and neurodegenerative disorders.

  6. Assessing Open-Ended Design Problems

    ERIC Educational Resources Information Center

    Bartholomew, Scott R.

    2017-01-01

    Interest in Technology and Engineering Education (TEE) has recently revolved around working to define/redefine who we are, and who we are not; while others in TEE are not interested in a change of identity. An emphasis on design, design education, and design assessment may help clarify the discussion surrounding the future direction of TEE.…

  7. Transcranial doppler ultrasonography should it be the first choice for persistent foramen ovale screening?

    PubMed Central

    2014-01-01

    Background Persistent foramen ovale (PFO) is considered a cause of cryptogenic stroke and a risk factor for neurological events in young patients. The reference standard for identifying a PFO is contrast-enhanced transesophageal echocardiography (TEE). The goal of this study was to evaluate the feasibility of transcranial color Doppler (TCD) and its diagnostic sensitivity compared with TEE. Methods We investigated 420 patients admitted to our department with cryptogenic stroke, transient ischemic attacks or other neurological symptoms. All patients underwent TCD and TEE evaluation. TCD and TEE examinations were performed according to a standardized procedure: air-mixed saline was injected into the right antecubital vein three times, while the Doppler signal was recorded during the Valsalva maneuver. During TCD the passage of contrast into the right-middle cerebral artery was recorded 25 seconds following the Valsalva maneuver. Results We detected a right-to-left shunt in 220 patients (52.3%) and no-shunts in 159 patients (37.9%) with both TCD and TEE. In 20 (4.8%) patients TEE did not reveal contrast passage which was then detected by TCD. In 21 (5.0%) patients only TEE revealed a PFO. The feasibility of both methods was 100%. TCD had a sensitivity of 95% and a specificity of 92% in the diagnosis of PFO. Conclusions TCD has a relatively good sensitivity and specificity. TCD and TEE are complementary diagnostic tests for PFO, but TCD should be recommended as the first choice for screening because of its simplicity, non-invasive character, low cost and high feasibility. PMID:24884981

  8. [Aneurysm of the atrial septum diagnosed by trans-esophageal echocardiography].

    PubMed

    Juszczyk, Z; Attir, A; Kamińska, M

    1991-01-01

    We report an uncommon case of atrial septal aneurysm associated with mitral valve prolapse. A 28 year old woman was studied with transthoracic and transesophageal echocardiography (TEE). Transthoracic echocardiography suggested mitral valve prolapse. TEE with color mapping was performed. Atrial septal aneurysm and mitral valve prolapse was found. The study has shown that TEE can evaluate accurately some of the anatomic features of atrial septal aneurysm and color flow mapping can provide accurate information about the blood flow in the lesion. We believe that TEE may be the safest and most accurate investigative technique for diagnosing this rare lesion.

  9. Longitudinal change in energy expenditure and effects on energy requirements of the elderly

    PubMed Central

    2013-01-01

    Background Very little is known about the longitudinal changes in energy requirements in late life. The purposes of this study were to: (1) determine the energy requirements in late life and how they changed during a 7 year time-span, (2) determine whether changes in fat free mass (FFM) were related to changes in resting metabolic rate (RMR), and (3) determine the accuracy of predicted total energy expenditure (TEE) to measured TEE. Methods TEE was assessed via doubly labeled water (DLW) technique in older adults in both 1999 (n = 302; age: 74 ± 2.9 yrs) and again in 2006 (n = 87 age: 82 ± 3.1 yrs). RMR was measured with indirect calorimetry, and body composition was assessed with dual-energy x-ray absorptiometry. Results The energy requirements in the 9th decade of life were 2208 ± 376 kcal/d for men and 1814 ± 337 kcal/d for women. This was a significant decrease from the energy requirements in the 8th decade of life in men (2482 ± 476 kcal/d vs. 2208 ± 376 kcal/d) but not in women (1892 ± 271 kcal/d vs. 1814 ± 337 kcal/d). In addition to TEE, RMR, and activity EE (AEE) also decreased in men, but not women, while FFM decreased in both men and women. The changes in FFM were correlated with changes in RMR for men (r = 0.49, p < 0.05) but not for women (r = −0.08, ns). Measured TEE was similar to Dietary Reference Intake (DRI) predicted TEE for men (2208 ± 56 vs. 2305 ± 35 kcal/d) and women (1814 ± 42 vs. 1781 ± 20 kcal/d). However, measured TEE was different than the World Health Organization (WHO) predicted TEE in men (2208 ± 56 vs. 2915 ± 31 kcal/d (p < 0.05)) and women (1814 ± 42 vs. 2315 ± 21 kcal/d (p < 0.05)). Conclusions TEE, RMR and AEE decreased in men, but not women, from the 8th to 9th decade of life. The DRI equation to predict TEE was comparable to measured TEE, while the WHO equation over-predicted TEE in our elderly population

  10. Comparison of total energy expenditure assessed by two devices in controlled and free-living conditions.

    PubMed

    Rousset, Sylvie; Fardet, Anthony; Lacomme, Philippe; Normand, Sylvie; Montaurier, Christophe; Boirie, Yves; Morio, Béatrice

    2015-01-01

    The objective of this study was to evaluate the validity of total energy expenditure (TEE) provided by Actiheart and Armband. Normal-weight adult volunteers wore both devices either for 17 hours in a calorimetric chamber (CC, n = 49) or for 10 days in free-living conditions (FLC) outside the laboratory (n = 41). The two devices and indirect calorimetry or doubly labelled water, respectively, were used to estimate TEE in the CC group and FLC group. In the CC, the relative value of TEE error was not significant (p > 0.05) for Actiheart but significantly different from zero for Armband, showing TEE underestimation (-4.9%, p < 0.0001). However, the mean absolute values of errors were significantly different between Actiheart and Armband: 8.6% and 6.7%, respectively (p = 0.05). Armband was more accurate for estimating TEE during sleeping, rest, recovery periods and sitting-standing. Actiheart provided better estimation during step and walking. In FLC, no significant error in relative value was detected. Nevertheless, Armband produced smaller errors in absolute value than Actiheart (8.6% vs. 12.8%). The distributions of differences were more scattered around the means, suggesting a higher inter-individual variability in TEE estimated by Actiheart than by Armband. Our results show that both monitors are appropriate for estimating TEE. Armband is more effective than Actiheart at the individual level for daily light-intensity activities.

  11. Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine.

    PubMed

    Zito, Concetta; Dattilo, Giuseppe; Oreto, Giuseppe; Di Bella, Gianluca; Lamari, Annalisa; Iudicello, Raffaella; Trio, Olimpia; Caracciolo, Giuseppe; Coglitore, Sebastiano; Arrigo, Francesco; Carerj, Scipione

    2009-05-01

    The aim of this study was to compare transthoracic echocardiography (TTE) and transcranial Doppler ultrasonography (TCD) with transesophageal echocardiography (TEE) in order to define the best clinical approach to patent foramen ovale (PFO) detection. In total, 72 consecutive patients (33 men) with a mean age of 49 +/- 13 years were prospectively enrolled. The TEE indication was cryptogenic stroke (36 patients) or migraine (36 patients, 22 with aura). All patients underwent standard TTE, TCD, and TEE examination. For any study, a contrast test was carried on using an agitated saline solution mixed with urea-linked gelatine (Haemaccel), injected as a rapid bolus via a right antecubital vein. A prolonged Valsalva maneuver was performed to improve test sensitivity. TEE identified a PFO in 65% of the whole population: 56.5% in the migraine cohort and 43.5% in the cryptogenic stroke cohort. TTE was able to detect a PFO in 55% of patients positive at TEE (54% negative predictive value, 100% positive predictive value, 55% sensitivity, and 100% specificity). TCD was able to identify a PFO in 97% of patients positive at TEE (89% negative predictive value, 98% positive predictive value, 94% sensitivity, and 96% specificity). In patients with cryptogenic stroke and migraine, there is a fair concordance (k = 0.89) between TCD and TEE in PFO recognition. Accordingly, TCD should be recommended as a simple, noninvasive, and reliable technique, whereas TEE indication should be restricted to selected patients. TTE is a very specific technique, whose major advantage is the ability to detect a large right-to-left shunt, particularly if associated with an atrial septal aneurysm.

  12. Differential transesophageal echocardiographic diagnosis between linear artifacts and intraluminal flap of aortic dissection or disruption.

    PubMed

    Vignon, P; Spencer, K T; Rambaud, G; Preux, P M; Krauss, D; Balasia, B; Lang, R M

    2001-06-01

    The relatively low specificity of transesophageal echocardiography (TEE) for the diagnosis of aortic dissection (AD) or traumatic disruption of the aorta (TDA) has been attributed to linear artifacts. We sought to determine the incidence of intra-aortic linear artifacts in a cohort of patients with suspected AD or TDA, to establish the differential TEE diagnostic criteria between these artifacts and true aortic flaps, and to evaluate their impact on TEE diagnostic accuracy. During an 8-year period, patients at high risk of AD (n = 261) or TDA (n = 90) who underwent a TEE study and had confirmed final diagnoses were studied. In an initial retrospective series, linear artifacts were observed within the ascending and descending aorta in 59 of 230 patients (26%) and 17 of 230 patients (7%), respectively. TEE findings associated with linear artifacts in the ascending aorta were as follows: displacement parallel to aortic walls; similar blood flow velocities on both sides; angle with the aortic wall > 85 degrees; and thickness > 2.5 mm. Diagnostic criteria of reverberant images in the descending aorta were as follows: displacement parallel to aortic walls, overimposition of blood flow, and similar blood flow velocities on both sides of the image. In a subsequent prospective series (n = 121), systematic use of these diagnostic criteria resulted in improved TEE specificity for the identification of true intra-aortic flaps. Misleading intra-aortic linear artifacts are frequently observed in patients undergoing a TEE study for suspected AD or TDA. Routine use of the herein-proposed diagnostic criteria promises to further improve TEE diagnostic accuracy in the setting of severely ill patients with potential need for prompt surgery.

  13. Toe thumb: a musculoskeletal disorder related to transesophageal echocardiography.

    PubMed

    Tewari, Prabhat; Raju, P S N; Neema, P K

    2014-01-01

    The musculoskeletal disorders (MSD) are common in healthcare providers and those who are doing sonography are also affected. There are reports of MSD in healthcare providers who do transthoracic echocardiography. Transesophageal echocardiography (TEE) is being regularly used in peri-operative setting. We describe MSD of hand in a cardiovascular and thoracic anesthesiologist who has been performing TEE scanning for 10% of his work-time in operating room and critical care area for the last 8 years. As the role of TEE is increasing and many doctors are doing it on a routine basis, the knowledge of association of MSD with TEE and measures to prevent it is important.

  14. Transesophageal Speckle-Tracking Echocardiography Improves Right Ventricular Systolic Function Assessment in the Perioperative Setting.

    PubMed

    Markin, Nicholas W; Chamsi-Pasha, Mohammed; Luo, Jiangtao; Thomas, Walker R; Brakke, Tara R; Porter, Thomas R; Shillcutt, Sasha K

    2017-02-01

    Perioperative evaluation of right ventricular (RV) systolic function is important to follow intraoperative changes, but it is often not possible to assess with transthoracic echocardiographic (TTE) imaging, because of surgical field constraints. Echocardiographic RV quantification is most commonly performed using tricuspid annular plane systolic excursion (TAPSE), but it is not clear whether this method works with transesophageal echocardiographic (TEE) imaging. This study was performed to evaluate the relationship between TTE and TEE TAPSE distances measured with M-mode imaging and in comparison with speckle-tracking TTE and TEE measurements. Prospective observational TTE and TEE imaging was performed during elective cardiac surgical procedures in 100 subjects. Speckle-tracking echocardiographic TAPSE distances were determined and compared with the TTE M-mode TAPSE standard. Both an experienced and an inexperienced user of the speckle-tracking echocardiographic software evaluated the images, to enable interobserver assessment in 84 subjects. The comparison between TTE M-mode TAPSE and TEE M-mode TAPSE demonstrated significant variability, with a Spearman correlation of 0.5 and a mean variance in measurement of 6.5 mm. There was equivalence within data pairs and correlations between TTE M-mode TAPSE and both speckle-tracking TTE and speckle-tracking TEE TAPSE, with Spearman correlations of 0.65 and 0.65, respectively. The average variance in measurement was 0.6 mm for speckle-tracking TTE TAPSE and 1.5 mm for speckle-tracking TEE TAPSE. Using TTE M-mode TAPSE as a control, TEE M-mode TAPSE results are not accurate and should not be used clinically to evaluate RV systolic function. The relationship between speckle-tracking echocardiographic TAPSE and TTE M-mode TAPSE suggests that in the perioperative setting, speckle-tracking TEE TAPSE might be used to quantitatively evaluate RV systolic function in the absence of TTE imaging. Copyright © 2016 American Society

  15. Efficient feature-based 2D/3D registration of transesophageal echocardiography to x-ray fluoroscopy for cardiac interventions

    NASA Astrophysics Data System (ADS)

    Hatt, Charles R.; Speidel, Michael A.; Raval, Amish N.

    2014-03-01

    We present a novel 2D/ 3D registration algorithm for fusion between transesophageal echocardiography (TEE) and X-ray fluoroscopy (XRF). The TEE probe is modeled as a subset of 3D gradient and intensity point features, which facilitates efficient 3D-to-2D perspective projection. A novel cost-function, based on a combination of intensity and edge features, evaluates the registration cost value without the need for time-consuming generation of digitally reconstructed radiographs (DRRs). Validation experiments were performed with simulations and phantom data. For simulations, in silica XRF images of a TEE probe were generated in a number of different pose configurations using a previously acquired CT image. Random misregistrations were applied and our method was used to recover the TEE probe pose and compare the result to the ground truth. Phantom experiments were performed by attaching fiducial markers externally to a TEE probe, imaging the probe with an interventional cardiac angiographic x-ray system, and comparing the pose estimated from the external markers to that estimated from the TEE probe using our algorithm. Simulations found a 3D target registration error of 1.08(1.92) mm for biplane (monoplane) geometries, while the phantom experiment found a 2D target registration error of 0.69mm. For phantom experiments, we demonstrated a monoplane tracking frame-rate of 1.38 fps. The proposed feature-based registration method is computationally efficient, resulting in near real-time, accurate image based registration between TEE and XRF.

  16. Energy expenditure and activity among Hadza hunter-gatherers.

    PubMed

    Pontzer, Herman; Raichlen, David A; Wood, Brian M; Emery Thompson, Melissa; Racette, Susan B; Mabulla, Audax Z P; Marlowe, Frank W

    2015-01-01

    Studies of total energy expenditure, (TEE; kcal/day) among traditional populations have challenged current models relating habitual physical activity to daily energy requirements. Here, we examine the relationship between physical activity and TEE among traditional Hadza hunter-gatherers living in northern Tanzania. Hadza adults were studied at two camps, with minimal intervention so as to monitor energy expenditure and activity during normal daily life. We measured daily walking distance and walking speed using wearable GPS units for 41 adults. For a subset of 30 adults, we measured TEE using doubly labeled water, three indices of work load (foraging return rate, maternal status, and number of dependent children), and urinary biomarkers of metabolic activity and stress (8-hydroxydeoxyguanosine, cortisol, and testosterone). Fat-free mass was the single strongest predictor of TEE among Hadza adults (r(2)  = 0.66, P < 0.001). Hadza men used greater daily walking distances and faster walking speeds compared with that of Hadza women, but neither sex nor any measure of physical activity or work load were correlated with TEE in analyses controlling for fat-free mass. Compared with developed, industrial populations, Hadza adults had similar TEE but elevated levels of metabolic stress as measured by 8-hydroxydeoxyguanosine. Our results indicate that daily physical activity may not predict TEE within traditional hunter-gatherer populations like the Hadza. Instead, adults with high levels of habitual physical activity may adapt by reducing energy allocation to other physiological activity. © 2015 Wiley Periodicals, Inc.

  17. Transesophageal echocardiography probe shutdown in a patient with hyperthermia.

    PubMed

    Saluja, Vandana; Singh, Gaganpal; Pandey, Chandrakant

    2016-01-01

    The use of transesophageal echocardiography (TEE) has been increasing over the past few years. It is considered a semi-invasive monitor and a safe diagnostic device. Though complications are rare, they must be known to operators who frequently perform TEE. TEE probes are known to cause tissue heating and damage on prolonged use. In this case report, we describe shutdown of the transesophageal probe in our patient with high-grade fever.

  18. Approaches for quantifying energy intake and %calorie restriction during calorie restriction interventions in humans: the multicenter CALERIE study

    PubMed Central

    Das, Sai Krupa; Bhapkar, Manjushri; Hadley, Evan C.; Roberts, Susan B.; Ravussin, Eric; Pieper, Carl; DeLany, James P.; Kraus, William E.; Rochon, James; Redman, Leanne M.

    2012-01-01

    Calorie restriction (CR) is a component of most weight loss interventions and a potential strategy to slow aging. Accurate determination of energy intake and %CR is critical when interpreting the results of CR interventions; this is most accurately achieved using the doubly labeled water method to quantify total energy expenditure (TEE). However, the costs and analytical requirements of this method preclude its repeated use in many clinical trials. Our aims were to determine 1) the optimal TEE assessment time points for quantifying average energy intake and %CR during long-term CR interventions and 2) the optimal approach for quantifying short-term changes in body energy stores to determine energy intake and %CR during 2-wk DLW periods. Adults randomized to a CR intervention in the multicenter CALERIE study underwent measurements of TEE by doubly labeled water and body composition at baseline and months 1, 3, and 6. Average %CR achieved during the intervention was 24.9 ± 8.7%, which was computed using an approach that included four TEE assessment time points (i.e., TEEbaseline, months 1, 3, and 6) plus the 6-mo change in body composition. Approaches that included fewer TEE assessments yielded %CR values of 23.4 ± 9.0 (TEEbaseline, months 3 and 6), 25.0 ± 8.7 (TEEbaseline, months 1 and 6), and 20.9 ± 7.1% (TEEbaseline, month 6); the latter approach differed significantly from approach 1 (P < 0.001). TEE declined 9.6 ± 9.9% within 2–4 wk of CR beginning and then stabilized. Regression of daily home weights provided the most reliable estimate of short-term change in energy stores. In summary, optimal quantification of energy intake and %CR during weight loss necessitates a TEE measurement within the first month of CR to capture the rapid reduction in TEE. PMID:22127229

  19. Use of Doubly Labeled Water to Validate a Physical Activity Questionnaire Developed for the Japanese Population

    PubMed Central

    Ishikawa-Takata, Kazuko; Naito, Yoshihiko; Tanaka, Shigeho; Ebine, Naoyuki; Tabata, Izumi

    2011-01-01

    Background No study has attempted to use the doubly labeled water (DLW) method to validate a physical activity questionnaire administered to a Japanese population. The development and refinement of such questionnaires require that physical activity components related to physical activity level be examined. Methods Among 226 Japanese men and women 20 to 83 years of age, total energy expenditure (TEE) was assessed using the Japan Arteriosclerosis Longitudinal Study Physical Activity Questionnaire (JALSPAQ), and the results were compared with TEE measured by the DLW method as a gold standard. Resting metabolic rate (RMR) was measured using the Douglas Bag method. Results The median TEE by DLW and physical activity level (PAL: TEE/RMR) were 11.21 MJ/day and 1.88, respectively, for men, and 8.42 MJ/day and 1.83 for women. JALSPAQ slightly underestimated TEE: the differences in mean and standard error were −1.15 ± 1.92 MJ/day. JALSPAQ and DLW TEE values were moderately correlated (Spearman correlation = 0.742, P < 0.001; intraclass correlation coefficient = 0.648, P < 0.001), and the 95% limit of agreement was −4.99 to 2.69 MJ. Underestimation of TEE by JALSPAQ was greater in active subjects than in less active subjects. Moderate and vigorous physical activity and physical activity during work (ie, occupational tasks and housework) were strongly related to physical activity level. However, the physical activity components that differentiated sedentary from moderately active subjects were not clear. Conclusions Physical activity level values on JALSPAQ and DLW were weakly correlated. In addition, estimation of TEE in active subjects should be improved, and the use of a questionnaire to differentiate activity in sedentary and moderately active subjects must be reassessed. PMID:21258166

  20. Transesophageal echocardiography probe shutdown in a patient with hyperthermia

    PubMed Central

    Saluja, Vandana; Singh, Gaganpal; Pandey, Chandrakant

    2016-01-01

    The use of transesophageal echocardiography (TEE) has been increasing over the past few years. It is considered a semi-invasive monitor and a safe diagnostic device. Though complications are rare, they must be known to operators who frequently perform TEE. TEE probes are known to cause tissue heating and damage on prolonged use. In this case report, we describe shutdown of the transesophageal probe in our patient with high-grade fever. PMID:26952152

  1. Validity of 24-h recalls in (pre-)school aged children: comparison of proxy-reported energy intakes with measured energy expenditure.

    PubMed

    Börnhorst, C; Bel-Serrat, S; Pigeot, I; Huybrechts, I; Ottavaere, C; Sioen, I; De Henauw, S; Mouratidou, T; Mesana, M I; Westerterp, K; Bammann, K; Lissner, L; Eiben, G; Pala, V; Rayson, M; Krogh, V; Moreno, L A

    2014-02-01

    Little is known about the validity of repeated 24-h dietary recalls (24-HDR) as a measure of total energy intake (EI) in young children. This study aimed to evaluate the validity of proxy-reported EI by comparison with total energy expenditure (TEE) measured by the doubly labeled water (DLW) technique. The agreement between EI and TEE was investigated in 36 (47.2% boys) children aged 4-10 years from Belgium and Spain using subgroup analyses and Bland-Altman plots. Low-energy-reporters (LER), adequate-energy-reporters (AER) and high-energy-reporters (HER) were defined from the ratio of EI over TEE by application of age- and sex-specific cut-off values. There was good agreement between means of EI (1500 kcal/day) and TEE (1523 kcal/day) at group level though in single children, i.e. at the individual level, large differences were observed. Almost perfect agreement between EI and TEE was observed in thin/normal weight children (EI: 1511 kcal/day; TEE: 1513 kcal/day). Even in overweight/obese children the mean difference between EI and TEE was only -86 kcal/day. Among the participants, 28 (78%) were classified as AER, five (14%) as HER and three (8%) as LER. Two proxy-reported 24-HDRs were found to be a valid instrument to assess EI on group level but not on the individual level. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  2. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    PubMed

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  3. A Mobile Phone App for Dietary Intake Assessment in Adolescents: An Evaluation Study

    PubMed Central

    Svensson, Åsa

    2015-01-01

    Background There is a great need for dietary assessment methods that suit the adolescent lifestyle and give valid intake data. Objective To develop a mobile phone app and evaluate its ability to assess energy intake (EI) and total energy expenditure (TEE) compared with objectively measured TEE. Furthermore, to investigate the impact of factors on reporting accuracy of EI, and to compare dietary intake with a Web-based method. Methods Participants 14 to 16 years of age were recruited from year nine in schools in Gothenburg, Sweden. In total, 81 adolescents used the mobile phone app over 1 to 6 days. TEE was measured with the SenseWear Armband (SWA) during the same or proximate days. Individual factors were assessed with a questionnaire. A total of 15 participants also recorded dietary intake using a Web-based method. Results The mobile phone app underestimated EI by 29% on a group level (P<.001) compared to TEE measured with the SWA, and there was no significant correlation between EI and TEE. Accuracy of EI relative to TEE increased with a weekend day in the record (P=.007) and lower BMI z-score (P=.001). TEE assessed with the mobile phone app was 1.19 times the value of TEE measured by the SWA on a group level (P<.001), and the correlation between the methods was .75 (P<.001). Analysis of physical activity levels (PAL) from the mobile phone app stratified by gender showed that accuracy of the mobile phone app was higher among boys. EI, nutrients, and food groups assessed with the mobile phone app and Web-based method among 15 participants were not significantly different and several were significantly correlated, but strong conclusions cannot be drawn due to the low number of participants. Conclusions By using a mobile phone dietary assessment app, on average 71% of adolescents’ EI was captured. The accuracy of reported dietary intake was higher with lower BMI z-score and if a weekend day was included in the record. The daily question in the mobile phone app

  4. A Mobile Phone App for Dietary Intake Assessment in Adolescents: An Evaluation Study.

    PubMed

    Svensson, Åsa; Larsson, Christel

    2015-11-03

    There is a great need for dietary assessment methods that suit the adolescent lifestyle and give valid intake data. To develop a mobile phone app and evaluate its ability to assess energy intake (EI) and total energy expenditure (TEE) compared with objectively measured TEE. Furthermore, to investigate the impact of factors on reporting accuracy of EI, and to compare dietary intake with a Web-based method. Participants 14 to 16 years of age were recruited from year nine in schools in Gothenburg, Sweden. In total, 81 adolescents used the mobile phone app over 1 to 6 days. TEE was measured with the SenseWear Armband (SWA) during the same or proximate days. Individual factors were assessed with a questionnaire. A total of 15 participants also recorded dietary intake using a Web-based method. The mobile phone app underestimated EI by 29% on a group level (P<.001) compared to TEE measured with the SWA, and there was no significant correlation between EI and TEE. Accuracy of EI relative to TEE increased with a weekend day in the record (P=.007) and lower BMI z-score (P=.001). TEE assessed with the mobile phone app was 1.19 times the value of TEE measured by the SWA on a group level (P<.001), and the correlation between the methods was .75 (P<.001). Analysis of physical activity levels (PAL) from the mobile phone app stratified by gender showed that accuracy of the mobile phone app was higher among boys. EI, nutrients, and food groups assessed with the mobile phone app and Web-based method among 15 participants were not significantly different and several were significantly correlated, but strong conclusions cannot be drawn due to the low number of participants. By using a mobile phone dietary assessment app, on average 71% of adolescents' EI was captured. The accuracy of reported dietary intake was higher with lower BMI z-score and if a weekend day was included in the record. The daily question in the mobile phone app about physical activity could accurately rank the

  5. Total energy expenditure in burned children using the doubly labeled water technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goran, M.I.; Peters, E.J.; Herndon, D.N.

    Total energy expenditure (TEE) was measured in 15 burned children with the doubly labeled water technique. Application of the technique in burned children required evaluation of potential errors resulting from nutritional intake altering background enrichments during studies and from the high rate of water turnover relative to CO2 production. Five studies were discarded because of these potential problems. TEE was 1.33 +/- 0.27 times predicted basal energy expenditure (BEE), and in studies where resting energy expenditure (REE) was simultaneously measured, TEE was 1.18 +/- 0.17 times REE, which in turn was 1.16 +/- 0.10 times predicted BEE. TEE was significantlymore » correlated with measured REE (r2 = 0.92) but not with predicted BEE. These studies substantiate the advantage of measuring REE to predict TEE in severely burned patients as opposed to relying on standardized equations. Therefore we recommend that optimal nutritional support will be achieved in convalescent burned children by multiplying REE by an activity factor of 1.2.« less

  6. Detection of patent foramen ovale by contrast transesophageal echocardiography.

    PubMed

    Chen, W J; Kuan, P; Lien, W P; Lin, F Y

    1992-06-01

    A series of 32 patients undergoing cardiac catheterization and/or operation to document the presence of patent foramen ovale (PFO) were studied. All were examined by contrast transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) during normal breathing and the Valsalva maneuver. A right-to-left shunt at the atrial level was visualized by contrast TEE in 14 patients during normal breathing and in 20 patients during the Valsalva maneuver. In comparison, contrast TTE revealed this shunt in only eight patients during normal breathing and in 12 patients during the Valsalva maneuver. All of the foramina proved to be patent by contrast TTE were also found by contrast TEE. All but one (19 of 20) patients, shown to have PFO by contrast TEE, could be confirmed at cardiac catheterization and/or operation. Using cardiac catheterization and/or operation as a gold standard, contrast TEE appears to be a more sensitive (100 percent vs 63 percent, p less than 0.005) and accurate (97 percent vs 78 percent, p less than 0.05) method than contrast TTE in the detection of PFO.

  7. Energy requirement assessed by doubly-labeled water method in patients with advanced amyotrophic lateral sclerosis managed by tracheotomy positive pressure ventilation.

    PubMed

    Ichihara, Noriko; Namba, Kazuyoshi; Ishikawa-Takata, Kazuko; Sekine, Kazunori; Takase, Mitsunori; Kamada, Yuko; Fujii, Seigo

    2012-10-01

    This study aimed to clarify the energy requirement in patients with amyotrophic lateral sclerosis (ALS) undergoing tracheostomy positive pressure ventilation with tracheostomy. Total energy expenditure (TEE) was measured in 10 hospitalized bedridden ALS patients using the doubly-labeled water (DLW) method. The mean TEE/day and TEE/fat- free mass estimated by DLW method were 934 ± 201 kcal/day and 34.8 ± 5.5 kcal/kg/day, respectively. The mean TEE/resting metabolic rate (RMR) was 0.85 when RMR was estimated by the Harris-Benedict equation, 0.91 by Dietary Reference Intake (DRI), and 0.97 by Ganpule's equation using fat-free mass (FFM). The ratios of TEE to measured RMR were 1.05, 1.15 and 1.23 in three patients. In conclusion, multiplying measured RMR by 1.1 to 1.2 is considered to be appropriate to estimate energy need. However, because it is difficult to measure RMR directly in a clinical setting, an appropriate equation for estimating RMR for ALS patient should be developed.

  8. Transesophageal echocardiography and intracardiac echocardiography differently predict potential technical challenges or failures of interatrial shunts catheter-based closure.

    PubMed

    Rigatelli, Gianluca; Rigateli, Gianluca; Cardaioli, Paolo; Braggion, Gabriele; Aggio, Silvio; Giordan, Massimo; Magro, Beatrice; Nascimben, Alberto; Favaro, Alberto; Roncon, Loris; Rincon, Loris

    2007-02-01

    We sought to prospectively assess the role of transesophageal (TEE) and intracardiac echocardiography (ICE) in detecting potential technical difficulties or failures in patients submitted to interatrial shunts percutaneous closure. We prospectively enrolled 46 consecutive patients (mean age 35+/-28, 8 years, 30 female) referred to our center for catheter-based closure of interatrial shunts. All patients were screened with TEE before the intervention. Patients who met the inclusion criteria underwent ICE study before the closure attempt (40 patients). TEE detected potential technical difficulties in 22.5% (9/40) patients, whereas ICE detected technical difficulties in 32.5% (13/40 patients). In patients with positive TEE/ICE the procedural success (92.4% versus 100% and, P = ns) and follow-up failure rate (7.7% versus 0%, P = ns) were similar to patients with negative TEE/ICE, whereas the fluoroscopy time (7 +/- 1.2 versus 5 +/- 0.7 minutes, P < 0.03), the procedural time (41 +/- 4.1 versus 30 +/- 8.2 minutes, P +/- 0.03), and technical difficulties rate (23.1% versus 0%, P = 0.013) were higher. Differences between ICE and TEE in the evaluation of rims, measurement of ASD or fossa ovalis, and detection of venous valve and embryonic septal membrane remnants impacted on technical challenges and on procedural and fluoroscopy times but did not influence the success rate and follow-up failure rate.

  9. Identification of Left Atrial Appendage Thrombi in Patients With Persistent and Long-Standing Persistent Atrial Fibrillation Using Intra-Cardiac Echocardiography and Cardiac Computed Tomography.

    PubMed

    Ikegami, Yukinori; Tanimoto, Kojiro; Inagawa, Kohei; Shiraishi, Yasuyuki; Fuse, Jun; Sakamoto, Munehisa; Momiyama, Yukihiko; Takatsuki, Seiji

    2017-12-25

    Intracardiac echocardiography (ICE) and cardiac computed tomography (CCT), in addition to standard transesophageal echocardiography (TEE), have been used to identify left atrial (LA) thrombi prior to ablation for atrial fibrillation (AF). The clinical advantages of this, however, remain unclear. This study therefore investigated the advantages of additional pre-procedural LA appendage (LAA) thrombus evaluation using ICE and the clinical value of CCT in persistent and long-standing persistent AF.Methods and Results:We analyzed data from 108 consecutive patients with persistent and long-standing persistent AF who were scheduled to undergo AF ablation. TEE was performed within 24 h prior to ablation. ICE was performed for 97 patients in whom a thrombus was not detected on TEE. CCT was performed in 95 patients. Thrombus or sludge was detected on TEE in 11 patients (10.3%), for whom ablation was cancelled. Four additional patients were diagnosed with LAA thrombus on ICE. When TEE and ICE were used as the reference for thrombus detection, the sensitivity, specificity, positive predictive value, and negative predictive value of CCT for identifying contrast defects in the LAA were 100%, 81.0%, 40.7%, and 100%, respectively. ICE combined with TEE increased the detection rate of LAA thrombi in patients with persistent and long-standing persistent AF. Moreover, CCT had high sensitivity and negative predictive value for LAA thrombus detection.

  10. [Systematic implementation of transthoracic echocardiography, transesophageal echocardiography and 24-hour Holter ECG for the detection of cardiac sources of embolism in patients with stroke or transient ischemic attack. A retrospective study of 220 patients].

    PubMed

    Vinsonneau, U; Leblanc, A; Buchet, J-F; Pangnarind-Heintz, V; Le Gal, G; Rohel, G; Paleiron, N; Piquemal, M; Blanchard, C; Zagnoli, F; Paule, P

    2014-09-01

    Embolism of cardiac origin accounts for around 20% of ischemic strokes. ECG and transthoracic echocardiography (TTE) are commonly obtained during the evaluation of patient of ischemic stroke but specific indications for the transesophageal (TEE) echocardiography and 24-hour Holter ECG (Holter) remain uncertain. The aim of this study is to report the contribution of TTE, TEE and Holter performed as a routine during the evaluation of patients with ischemic stroke (IS) or transient ischemic attack (TIA). This is a retrospective single-center study of 220 patients hospitalized between 1st January 2007 and 31st December 2010 for a first IS or TIA. One hundred and forty-three IS and 77 TIA are identified. The average age of patients was 66 years (18-88 years). TTE/TEE/24-hour Holter allowed the diagnosis of cardiac sources of embolism in 135 patents (61.3%). TTE/TEE identified potential source of cardiogenic embolism in 126 patients (52.2%). Twenty four-hour Holter ECG tracked supraventricular arrhythmia in 15 patients (6.7%), 9 (4%) which had non-contributory ultrasound assessment. The systematic implementation of TTE/TEE/Holter is useful for identifying potential sources of cardiogenic embolism. The performance of TEE remains above the TTE. Holter should be recommended because it is a cost effective and non-invasive tool. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. Diagnostic accuracy of transesophageal echocardiogram for the detection of patent foramen ovale: a meta-analysis.

    PubMed

    Mojadidi, Mohammad Khalid; Bogush, Nikolay; Caceres, Jose Diego; Msaouel, Pavlos; Tobis, Jonathan M

    2014-07-01

    Patent foramen ovale (PFO) is a remnant of the fetal circulation present in 20% of the population. Right-to-left shunting (RLS) through a PFO has been linked to the pathophysiology of stroke, migraine with aura, and hypoxemia. While different imaging modalities including transcranial Doppler, intra-cardiac echo, and transthoracic echo (TTE) have often been used to detect RLS, transesophageal echo (TEE) bubble study remains the gold standard for diagnosing PFO. The aim of this study was to determine the relative accuracy of TEE in the detection of PFO. A systematic review of Medline, using a standard approach for meta-analysis, was performed for all prospective studies assessing accuracy of TEE in the detection of PFO using confirmation by autopsy, cardiac surgery, and/or catheterization as the reference. Search results revealed 3105 studies; 4 met inclusion criteria. A total of 164 patients were included. TEE had a weighted sensitivity of 89.2% (95% CI: 81.1-94.7%) and specificity of 91.4% (95% CI: 82.3-96.8%) to detect PFO. The overall positive likelihood ratio (LR+) was 5.93 (95% CI: 1.30-27.09) and the overall negative likelihood ratio (LR-) was 0.22 (95% CI: 0.08-0.56). While TEE bubble study is considered to be the gold standard modality for diagnosing PFO, some PFOs may still be missed or misdiagnosed. It is important to understand the limitations of TEE and perhaps use other highly sensitive screening tests, such as transcranial doppler (TCD), in conjunction with TEE before scheduling a patient for transcatheter PFO closure. © 2013, Wiley Periodicals, Inc.

  12. Estimating activity energy expenditure: how valid are physical activity questionnaires?

    PubMed

    Neilson, Heather K; Robson, Paula J; Friedenreich, Christine M; Csizmadi, Ilona

    2008-02-01

    Activity energy expenditure (AEE) is the modifiable component of total energy expenditure (TEE) derived from all activities, both volitional and nonvolitional. Because AEE may affect health, there is interest in its estimation in free-living people. Physical activity questionnaires (PAQs) could be a feasible approach to AEE estimation in large populations, but it is unclear whether or not any PAQ is valid for this purpose. Our aim was to explore the validity of existing PAQs for estimating usual AEE in adults, using doubly labeled water (DLW) as a criterion measure. We reviewed 20 publications that described PAQ-to-DLW comparisons, summarized study design factors, and appraised criterion validity using mean differences (AEE(PAQ) - AEE(DLW), or TEE(PAQ) - TEE(DLW)), 95% limits of agreement, and correlation coefficients (AEE(PAQ) versus AEE(DLW) or TEE(PAQ) versus TEE(DLW)). Only 2 of 23 PAQs assessed most types of activity over the past year and indicated acceptable criterion validity, with mean differences (TEE(PAQ) - TEE(DLW)) of 10% and 2% and correlation coefficients of 0.62 and 0.63, respectively. At the group level, neither overreporting nor underreporting was more prevalent across studies. We speculate that, aside from reporting error, discrepancies between PAQ and DLW estimates may be partly attributable to 1) PAQs not including key activities related to AEE, 2) PAQs and DLW ascertaining different time periods, or 3) inaccurate assignment of metabolic equivalents to self-reported activities. Small sample sizes, use of correlation coefficients, and limited information on individual validity were problematic. Future research should address these issues to clarify the true validity of PAQs for estimating AEE.

  13. Intracardiac versus transesophageal echocardiography for left atrial appendage occlusion with watchman.

    PubMed

    Frangieh, Antonio H; Alibegovic, Jasmina; Templin, Christian; Gaemperli, Oliver; Obeid, Slayman; Manka, Robert; Holy, Erik W; Maier, Willibald; Lüscher, Thomas F; Binder, Ronald K

    2017-08-01

    Left atrial appendage occlusion (LAAO) is mostly performed by transesophageal echocardiography (TEE) guidance. Intracardiac echocardiography (ICE) may be an alternative imaging modality for LAAO that precludes the need for general anesthesia or sedation. All consecutive single center, single operator LAAO candidates were analyzed. Baseline clinical and procedural characteristics and in-hospital outcomes were compared between patients in whom a Watchman was implanted with ICE vs. TEE guidance. In 76 consecutive patients the Watchman device was deployed under ICE in 32 patients (42%) and under TEE guidance in 44 patients (58%). Baseline characteristics were comparable between groups, except that patients in the TEE group were older (81 [75-85] years vs. 75 [68-80] years, P = 0.007). Total injected contrast media as well as fluoroscopy time were comparable between groups (90 ml [54-140] vs. 85 ml [80-110], P = 0.86 and 7.9 min [6.4-15.5] vs. 9.8 min [7.0-13.2], P = 0.51, for TEE vs. ICE, respectively). However, time from femoral venous puncture to transseptal puncture and to closure was longer in the ICE group (14 min [7.3-20] vs. 6 min [3.3-11], P = 0.007 and 48 min [40-60] vs. 34.5 min [27-44], P = 0.003, respectively). In the TEE group one patient suffered esophageal erosion with bleeding, which was managed conservatively and one non-LAAO related in-hospital mortality occurred in an 88-year-old patient. Device implantation success rate was 100% in both groups. No device embolization, no significant peri-device leak, no tamponade, no stroke, and no access site bleeding occurred in any patient. Total hospital stay for stand-alone LAAO was comparable between groups (2 days [2-2] vs. 2 days [2-3.3], P = 0.17, in ICE vs. TEE, respectively). ICE guidance for LAAO with the Watchman device is feasible and comparable to TEE and may become the preferred imaging modality for LAAO. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    PubMed

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  15. Total Energy Expenditure, Energy Intake, and Body Composition in Endurance Athletes Across the Training Season: A Systematic Review.

    PubMed

    Heydenreich, Juliane; Kayser, Bengt; Schutz, Yves; Melzer, Katarina

    2017-12-01

    Endurance athletes perform periodized training in order to prepare for main competitions and maximize performance. However, the coupling between alterations of total energy expenditure (TEE), energy intake, and body composition during different seasonal training phases is unclear. So far, no systematic review has assessed fluctuations in TEE, energy intake, and/or body composition in endurance athletes across the training season. The purpose of this study was to (1) systematically analyze TEE, energy intake, and body composition in highly trained athletes of various endurance disciplines and of both sexes and (2) analyze fluctuations in these parameters across the training season. An electronic database search was conducted on the SPORTDiscus and MEDLINE (January 1990-31 January 2015) databases using a combination of relevant keywords. Two independent reviewers identified potentially relevant studies. Where a consensus was not reached, a third reviewer was consulted. Original research articles that examined TEE, energy intake, and/or body composition in 18-40-year-old endurance athletes and reported the seasonal training phases of data assessment were included in the review. Articles were excluded if body composition was assessed by skinfold measurements, TEE was assessed by questionnaires, or data could not be split between the sexes. Two reviewers assessed the quality of studies independently. Data on subject characteristics, TEE, energy intake, and/or body composition were extracted from the included studies. Subjects were categorized according to their sex and endurance discipline and each study allocated a weight within categories based on the number of subjects assessed. Extracted data were used to calculate weighted means and standard deviations for parameters of TEE, energy intake, and/or body composition. From 3589 citations, 321 articles were identified as potentially relevant, with 82 meeting all of the inclusion criteria. TEE of endurance athletes was

  16. 97. VIEW OF PIER EXTENSION WITH RAMP IN FOREGROUND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    97. VIEW OF PIER EXTENSION WITH RAMP IN FOREGROUND AND 4TH TEE IN BACKGROUND, LOOKING SOUTHWEST FROM 3RD TEE - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  17. Benzocaine-induced methemoglobinemia based on the Mayo Clinic experience from 28 478 transesophageal echocardiograms: incidence, outcomes, and predisposing factors.

    PubMed

    Kane, Garvan C; Hoehn, Suzette M; Behrenbeck, Thomas R; Mulvagh, Sharon L

    2007-10-08

    The potentially life-threatening condition of methemoglobinemia is characterized by cyanosis, low pulse oximetric readings, and normal arterial Po(2) values. Acquired methemoglobinemia has been linked to the use of the topical anesthetic benzocaine in endoscopic procedures, including transesophageal echocardiography (TEE). Yet, the incidence of benzocaine-induced methemoglobinemia with TEE and the clinical factors associated with its development are unclear. All cases of methemoglobinemia complicating TEE at our institution (from January 1, 1999, to July 1, 2006) were identified by a comprehensive review of medical records and echocardiography and pharmacy databases. During 90 months among 28 478 TEEs, 19 cases of methemoglobinemia were identified, with a mean +/- SD methemoglobin level of 32% +/- 15%. All patients were cyanotic, with low oxygen saturations. Eighteen of 19 patients received methylene blue (mean +/- SD dose, 1.3 +/- 0.4 mg/kg of body weight), with resolution of symptoms and signs. One of 19 cases resolved spontaneously. Compared with a random sample of 190 patients undergoing TEE, the age, sex, body mass index, left ventricular systolic function, and dose of sedation (midazolam hydrochloride, fentanyl citrate, or both) were similar in the 2 groups. However, study patients who developed methemoglobinemia were more likely to be hospitalized (89.5% vs 57.6%, P =.005), be anemic (84.2% vs 44.7%, P =.002), and have active systemic infection (68.4% vs 6.8%; P < .001) at the time of TEE compared with the random control cohort. In a large series of patients undergoing TEE, the incidence of methemoglobinemia is low (1 case per 1499 [0.067%; 95% confidence interval, 0.040%-0.100%]) and has a good outcome if promptly recognized and treated. Clinical factors associated with the development of methemoglobinemia include sepsis, anemia, and hospitalization. Minimizing or avoiding the use of benzocaine in these patients is recommended.

  18. Routine transesophageal echocardiography for the diagnosis of aortic disruption in trauma patients without enlarged mediastinum.

    PubMed

    Vignon, P; Lagrange, P; Boncoeur, M P; Francois, B; Gastinne, H; Lang, R M

    1996-03-01

    To assess the value of routine transesophageal echocardiography (TEE) in diagnosing traumatic disruption of the aorta (TDA) in trauma patients presenting without enlarged mediastinum on chest x-ray films. Prospective study. TEE was routinely performed to exclude the presence of TDA in patients who sustained severe trauma secondary to abrupt deceleration collisions and presented with an upper mediastinum of fewer than 8 cm on supine chest x-ray films. Patients were divided into two groups according to the presence (group I) or absence (group II) of mediastinal hematoma diagnosed during TEE examination. Radiographic signs regarded as indicators of the presence of TDA were evaluated in both groups. Among the 40 consecutive patients studied, TEE demonstrated two cases of TDA associated with a mediastinal hematoma that were confirmed by both aortography and surgery. One of the patients had a normal mediastinum on presentation chest x-ray films, and the other only exhibited a blurred aortic knob. Radiographic mediastinal abnormalities suggestive of TDA were observed in 13 patients, but chest x-ray films were unremarkable in 12 patients. Twenty patients had multiple rib fractures. The frequency of chest radiographic abnormalities was not significantly higher in group I (n = 6) when compared with group II patients (n = 34). TEE examination demonstrated a normal thoracic aorta in 35 patients and was nondiagnostic in 3 patients (normal aortography). TEE should be routinely performed in victims of violent deceleration collisions, even in patients presenting apparently normal mediastinum on supine chest radiography.

  19. Association of energy intake and expenditure with obesity: A cross-sectional study of 150 pediatric patients following treatment for leukemia.

    PubMed

    Srivastava, Richa; Batra, Atul; Dhawan, Deepa; Bakhshi, Sameer

    2017-02-01

    Increased obesity in leukemia survivors has been attributed to chemotherapy and radiation. Data on total energy intake (TEI) and total energy expenditure (TEE) are lacking in obese childhood leukemia patients after completion of therapy from India. We conducted a cross-sectional study in pediatric acute leukemia patients after completion of therapy wherein energy intake was assessed by 24-hour recall method. TEE was calculated using Harris-Benedict equation, by assessing the physical activity level using Physical Activity Questionnaire for children and basal metabolic rate by World Health Organization equation. Indian Academy of Pediatrics 2015 guidelines for BMI were used for defining overweight and obesity. Nutritional status was assessed in 150 leukemia patients after completion of therapy. Twenty-five percent of leukemia patients after completion of therapy were overweight and obese versus 11% of healthy controls (p = 0.042). The mean ratio of TEI/required energy intake (REI), TEE/required energy expenditure (REE), and (TEI:REI)/(TEE:REE) were significantly higher in overweight and obese group versus nonobese survivors (p < 0.001, p = 0.091, p < 0.001, respectively). Multivariate analysis showed higher income (HR-2.3, p = 0.04), increased TEI/REI (HR-4, p = 0.049) and higher (TEI:REI)/(TEE:REE) (HR-3.1, p = 0.039) to be significant factors predicting obesity. Obesity in leukemia patients after completion of therapy is associated with increased energy intake, causing imbalance between energy intake and TEE in these patients.

  20. Use of transesophageal echocardiography and contrast echocardiography in the evaluation of cardiac masses.

    PubMed

    Xia, Hongmei; Gan, Ling; Jiang, Yan; Tang, Qi; Zhang, Ping; Tang, Xuefeng; Wen, Li; Liu, Zheng; Gao, Yunhua

    2017-06-01

    To determine whether the combination of transesophageal echocardiography (TEE) and contrast echocardiography (CE) accurately diagnose suspected cardiac masses using large sample data. Patients with cardiac masses undergoing surgical treatment were enrolled in this study. Routine transthoracic echocardiography (TTE) and TEE examinations were carried out, and CE examinations were carried out when needed. All patients' clinical data and imaging features were retrospectively reviewed. Surgery and histopathology served as the gold standard for diagnosing cardiac masses. A total of 252 consecutive patients were included in this study. Sixteen patients were lost to follow-up and were excluded from the study. The combinations of TEE and CE yielded the correct pathologic diagnosis in 225 of 230 patients (97.8%), while CT yielded the correct pathologic diagnosis in 122 of 141 patients (86.5%), p<0.01. TEE yielded the correct pathologic diagnosis in 219 of 226 patients (96.9%), and CE yielded the correct pathologic diagnosis in 45 of 48 patients (93.8%). TTE alone yielded the correct pathologic diagnosis in 163 of 236 patients (69.1%), p<0.001 for all. TEE imaging provided detailed and precise information regarding cardiovascular morphology, anatomy, hemodynamics and function, and CE provided information regarding tissue characteristics without subjecting patients to radiation exposure. The combination of TEE and CE is feasible for the detection of suspected cardiac masses, especially in diagnosing and differentiating between benign and malignant lesions. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. The Effect of Perioperative Rescue Transesophageal Echocardiography on the Management of Trauma Patients

    PubMed Central

    Griffee, Matthew J.; Singleton, Andrew; Zimmerman, Joshua M.; Morgan, David E.; Nirula, Raminder

    2018-01-01

    To evaluate the effect of rescue transesophageal echocardiography (TEE) on the management of trauma patients, we reviewed imaging and charts of unstable trauma patients at a level I trauma center. Critical rescue TEE findings included acute right ventricular failure, stress cardiomyopathy, type B aortic dissection, mediastinal air, and dynamic left ventricular outflow tract obstruction. Left ventricular filling was classified as low (underfilled) in 57% of all cases. Rescue TEE revealed a variety of new diagnoses and led to a change in resuscitation strategy about half of the time. PMID:27301053

  2. Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images.

    PubMed

    Haak, Alexander; Vegas-Sánchez-Ferrero, Gonzalo; Mulder, Harriët W; Ren, Ben; Kirişli, Hortense A; Metz, Coert; van Burken, Gerard; van Stralen, Marijn; Pluim, Josien P W; van der Steen, Antonius F W; van Walsum, Theo; Bosch, Johannes G

    2015-06-01

    Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations. Dice coefficients and point-to-surface distances were used to determine segmentation accuracy. ASM segmentations were successful in 19 of 20 cases. The median Dice coefficient for all successful segmentations versus the average observer ranged from 90% to 71% compared with an inter-observer range of 95% to 84%. The

  3. 77 FR 52761 - Notice of Lodging of Consent Decrees Under the Comprehensive Environmental Response, Compensation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... Corporation, Cyprus Amax Minerals Company, Inc., Blue Tee Corp., and Homestake Mining Company of California... to settle their liability at the Site. Cyprus Mines Corporation, Cyprus Amax Minerals Company, Inc... Corporation, Cyprus Amax Minerals Company, Inc., Blue Tee Corp., and Homestake Mining Company of California...

  4. A unique case of "double-orifice aortic valve"-comprehensive assessment by 2-, 3-dimensional, and color Doppler echocardiography.

    PubMed

    Stirrup, James E; Cowburn, Peter J; Pousios, Dimitrios; Ohri, Sunil K; Shah, Benoy N

    2016-09-01

    Transesophageal echocardiography (TEE) is a powerful imaging tool for the comprehensive assessment of valvular structure and function. TEE may be of added benefit when anatomy is difficult to delineate accurately by transthoracic echocardiography. In this article, we present 2-, 3-dimensional, and color Doppler TEE images from a male patient with aortic stenosis. A highly unusual and complex pattern of valvular calcification created a functionally "double-orifice" valve. Such an abnormality may have implications for the accuracy of continuous-wave Doppler echocardiography, which assumes a single orifice valve in native aortic valves. © 2016, Wiley Periodicals, Inc.

  5. Three-dimensional transesophageal echocardiography: Principles and clinical applications.

    PubMed

    Vegas, Annette

    2016-10-01

    A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE) matrix array probes include (a) live, (b) zoom, (c) full volume (FV), and (d) color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  6. Diagnosis of the prosthetic heart valve pannus formation with real-time three-dimensional transoesophageal echocardiography.

    PubMed

    Ozkan, Mehmet; Gündüz, Sabahattin; Yildiz, Mustafa; Duran, Nilüfer Eksi

    2010-05-01

    Prosthetic heart valve obstruction (PHVO) caused by pannus formation is an uncommon but serious complication. Although two-dimensional transesophageal echocardiography (2D-TEE) is the method of choice in the evaluation of PHVO, visualization of pannus is almost impossible with 2D-TEE. While demonstrating the precise aetiology of PHVO is essential for guiding the therapy, either thrombolysis for valve thrombosis or surgery for pannus formation, more sophisticated imaging techniques are needed in patients with suspected pannus formation. We present real-time 3D-TEE imaging in a patient with mechanical mitral PHVO, clearly demonstrating pannus overgrowth.

  7. An update on intraoperative three-dimensional transesophageal echocardiography

    PubMed Central

    2017-01-01

    Transesophageal echocardiography (TEE) was first used routinely in the operating rooms in the 1980s to facilitate surgical decision-making. Since then, TEE has evolved from the standard two-dimensional (2D) exam to include focused real-time three-dimensional (RT-3D) imaging both inside and outside the operating rooms. Improved spatial and temporal resolution due to technological advances has expedited surgical interventions in diseased valves. 3D imaging has also emerged as a crucial adjunct in percutaneous interventions for structural heart disease. With continued advancement in software, RT-3D TEE will continue to impact perioperative decisions. PMID:28540070

  8. Transcanal endoscopic ear surgery for perilymphatic fistula after electric acoustic stimulation.

    PubMed

    Omichi, Ryotaro; Kariya, Shin; Maeda, Yukihide; Nishizaki, Kazunori

    2018-06-01

    Transcanal endoscopic ear surgery (TEES) will become a very useful therapeutic option. A perilymphatic fistula (PLF) is defined as sudden sensorineural hearing loss and/or vertigo caused by leakage of the perilymph through a fistula from the oval window and/or round window. We report a case of PLF after electric acoustic stimulation (EAS), a kind of cochlear implant, successfully treated by TEES. A 38-year-old man presented to our hospital with vertigo and hearing loss (HL). His vertigo was induced by Valsalva maneuvers. Eight months ago, he underwent EAS for his right ear for congenital sensorineural HL. Although he maintained his hearing level after EAS, his pure tone audiogram this time showed deterioration of hearing at low frequencies in his right ear. A diagnosis of right PLF was made. After confirming the non-effectiveness of oral prednisolone treatment, PLF repair surgery to patch the oval and round windows by TEES was performed. His vertigo did not recur after the surgery. To the best of our knowledge, this is the first report of PLF repair surgery by TEES without a microscope. The wide-field view of the middle ear by TEES was useful to prevent electrode damage in a PLF patient with a cochlear implant. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Therapeutic implications of transesophageal echocardiography after transthoracic echocardiography on acute stroke patients

    PubMed Central

    de Abreu, Tiago Tribolet; Mateus, Sonia; Carreteiro, Cecilia; Correia, Jose

    2008-01-01

    Background The role of transesophageal echocardiography (TEE) in the evaluation of acute stroke patients is still ill-defined. We conducted a prospective observational study to find the prevalence of TEE findings that indicate anticoagulation as beneficial, in acute ischemic stroke patients without indication for anticoagulation based on clinical, electrocardiographic and transthoracic echocardiography (TTE) findings. Methods We prospectively studied all patients referred to our laboratory for TTE and TEE. Patients were excluded if the diagnosis was not acute ischemic stroke or if they had an indication for anticoagulation based on clinical, electrocardiographic, or TTE data. Patients with TEE findings that might indicate anticoagulation as beneficial were identified. Results A total of 84 patients with acute ischemic stroke and without indication for anticoagulation based on clinical and electrocardiographic or TTE data were included in the study. Findings indicating anticoagulation as beneficial were found in 32.1%: spontaneous echo contrast (1.2%), complex aortic atheroma (27.4%), thrombus (8.3%), and simultaneous patent foramen ovale and atrial septal aneurysm (2.4%). Conclusions The results of our study show that TEE can have therapy implications in 32.1% of ischemic stroke patients in sinus rhythm and with TTE with no indication for anticoagulation. PMID:18629351

  10. Accuracy of topological entanglement entropy on finite cylinders.

    PubMed

    Jiang, Hong-Chen; Singh, Rajiv R P; Balents, Leon

    2013-09-06

    Topological phases are unique states of matter which support nonlocal excitations which behave as particles with fractional statistics. A universal characterization of gapped topological phases is provided by the topological entanglement entropy (TEE). We study the finite size corrections to the TEE by focusing on systems with a Z2 topological ordered state using density-matrix renormalization group and perturbative series expansions. We find that extrapolations of the TEE based on the Renyi entropies with a Renyi index of n≥2 suffer from much larger finite size corrections than do extrapolations based on the von Neumann entropy. In particular, when the circumference of the cylinder is about ten times the correlation length, the TEE obtained using von Neumann entropy has an error of order 10(-3), while for Renyi entropies it can even exceed 40%. We discuss the relevance of these findings to previous and future searches for topological ordered phases, including quantum spin liquids.

  11. Incidental movement, lifestyle-embedded activity and sleep: new frontiers in physical activity assessment.

    PubMed

    Tremblay, Mark S; Esliger, Dale W; Tremblay, Angelo; Colley, Rachel

    2007-01-01

    Canadian public health messages relating to physical activity have historically focused on the prescription of purposeful exercise, most often assessing leisure-time physical activity (LTPA). Although LTPA contributes to total energy expenditure (TEE), a large part of the day remains neglected unless one also considers the energy expended outside of purposeful exercise. This paper reviews the potential impact of incidental (non-exercise or non-purposeful) physical activity and lifestyle-embedded activities (chores and incidental walking) upon TEE and indicators of health. Given that incidental movement occurs sporadically throughout the day, this form of energy expenditure is perhaps most vulnerable to increasingly ubiquitous mechanization and automation. The paper also explores the relationship of physical inactivity, including sleep, to physical activity, TEE, and health outcomes. Suggestions are provided for a more comprehensive physical activity recommendation that includes all components of TEE. Objective physical activity monitors with time stamps are considered as a better means to capture and examine human movements over the entire day.

  12. The transesophageal echocardiography simulator based on computed tomography images.

    PubMed

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  13. Real-time catheter localization and visualization using three-dimensional echocardiography

    NASA Astrophysics Data System (ADS)

    Kozlowski, Pawel; Bandaru, Raja Sekhar; D'hooge, Jan; Samset, Eigil

    2017-03-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) is increasingly used during minimally invasive cardiac surgeries (MICS). In many cath labs, RT3D-TEE is already one of the requisite tools for image guidance during MICS. However, the visualization of the catheter is not always satisfactory making 3D- TEE challenging to use as the only modality for guidance. We propose a novel technique for better visualization of the catheter along with the cardiac anatomy using TEE alone - exploiting both beamforming and post processing methods. We extended our earlier method called Delay and Standard Deviation (DASD) beamforming to 3D in order to enhance specular reflections. The beam-formed image was further post-processed by the Frangi filter to segment the catheter. Multi-variate visualization techniques enabled us to render both the standard tissue and the DASD beam-formed image on a clinical ultrasound scanner simultaneously. A frame rate of 15 FPS was achieved.

  14. The potential impact of contemporary transthoracic echocardiography on the management of patients with native valve endocarditis: a comparison with transesophageal echocardiography.

    PubMed

    Casella, Francesco; Rana, Bushra; Casazza, Giovanni; Bhan, Amit; Kapetanakis, Stam; Omigie, Joe; Reiken, Joseph; Monaghan, Mark J

    2009-09-01

    Between 1987 and 1994, several studies demostrated transthoracic echocardiography (TTE) to be less sensitive than transesophageal echocardiography (TEE) in detecting native valve endocarditis. Recent technologic advances, especially the introduction of harmonic imaging and digital processing and storage, have improved TTE image quality. The aim of this study was to determine the diagnostic accuracy of contemporary TTE. Between 2003 and 2007, 75 patients underwent both TTE and TEE for clinically suspected infective endocarditis. The diagnostic accuracy of TTE was assessed using transesophageal echocardiography as the gold standard for diagnosis of endocarditis. Of the 75 patients in this study, 33 were found to be positive by TEE. The sensitivity for detection of infective endocarditis by TTE was 81.8%. It provided good image quality in 81.5% of cases; in these patients sensitivity was even greater (89.3%). Contemporary TTE has improved the diagnostic accuracy of infective endocarditis by ameliorating image quality; it provides an accurate assessment of endocarditis and may reduce the need for TEE.

  15. NAREM Journal. Volume 1, 1978.

    ERIC Educational Resources Information Center

    Narem Journal, 1978

    1978-01-01

    Eight articles are included in the journal of the National Association for Remedial Education, Malaysia (NAREM). Chua Tee Tee describes the history and objectives of NAREM. Alec Williams reviews philosophical issues in remedial education. Khoo Phon Sai discusses cognitive, social, and emotional characteristics of slow learners and considers…

  16. Interatrial septum motion but not Doppler assessment predicts elevated pulmonary capillary wedge pressure in patients undergoing cardiac surgery.

    PubMed

    Haji, Darsim L; Ali, Mohamed M; Royse, Alistair; Canty, David J; Clarke, Sandy; Royse, Colin F

    2014-10-01

    Left atrial pressure and its surrogate, pulmonary capillary wedge pressure (PCWP), are important for determining diastolic function. The role of transthoracic echocardiography (TTE) in assessing diastolic function is well established in awake subjects. The objective was to assess the accuracy of predicting PCWP by TTE and transesophageal echocardiography (TEE) during coronary artery surgery. In 27 adult patients undergoing on-pump coronary artery surgery, simultaneous echocardiographic and hemodynamic measurements were obtained immediately before anesthesia (TTE), after anesthesia and mechanical ventilation (TTE and TEE), during conduit harvest (TEE), and after separation from cardiopulmonary bypass (TEE). Twenty patients had an ejection fraction (EF) of 0.5 or greater. With the exception of E/e' and S/D ratios, echocardiographic values changed over the echocardiographic studies. In patients with low EF, E velocity, deceleration time, pulmonary vein D, S/D, and E/e' ratios correlated well with PCWP before anesthesia. After induction of anesthesia using TTE or TEE, correlations were poor. In normal EF patients, correlations were poor for both TEE and TTE at all five stages. The sensitivity and specificity of echocardiographic values were not high enough to predict raised PCWP except for a fixed curve pattern of interatrial septum (area under the curve 0.89 for PCWP ≥ 17, and 0.98 for ≥ 18 mmHg) and S/D less than 1 (area under the curve 0.74 for PCWP ≥ 17, and 0.78 for ≥ 18 mmHg). Doppler assessment of PCWP was neither sensitive nor specific enough to be clinically useful in anesthetized patients with mechanical ventilation. The fixed curve pattern of the interatrial septum was the best predictor of raised PCWP.

  17. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography.

    PubMed

    Yamasaki, Yuzo; Nagao, Michinobu; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Sakamoto, Ichiro; Yamamura, Kenichiro; Yabuuchi, Hidetake; Honda, Hiroshi

    2017-02-01

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. • Quantification of left-to-right shunting can be performed reliably and accurately by CT. • The sizes of defects and rims can be measured accurately using 256-slice CT. • 256-slice CT permits pretreatment evaluation of ASD non-invasively and comprehensively.

  18. Intraoperative three-dimensional transesophageal echocardiography for assessing the defect geometries of mitral prosthetic paravalvular leak during transcatheter closure.

    PubMed

    Wei, Jeng; Yin, Wei-Hsian; Lee, Yung-Tsai; Hsiung, Ming C; Tsai, Shen-Kou; Chuang, Yi Cheng; Ou, Ching-Huei; Chou, Yi-Pen

    2015-03-01

    Paravalvular leaks (PVLs) are a common complication of prosthetic valve replacement. Use of the transcatheter intervention technique is a suitable alternative in high-risk patients who may not tolerate repeat surgery. Common reasons for failure of this demanding intervention include poor imaging quality and unsuitable anatomy. The purpose of this study was to assess the usefulness and the incremental value of real-time three-dimensional (RT 3D) transesophageal echocardiography (TEE) over two-dimensional (2D) TEE findings in the evaluation of the geometry and track of mitral PVLs during transcatheter closure. Five patients with six mitral PVLs at high risk for repeat surgery underwent transcatheter leak closure. Intraoperative RT 3DTEE was used to assess the location, shape, number, and size of the defects. Transapical approaches were used in all cases with fluoroscopic and RT 3D TEE guidance of the wire and catheter, device positioning, and assessment of residual leak after the procedure. In all of the cases, defects with irregular crescent shapes and distorted tracks were clearly delineated by RT 3D TEE. This was compared to those results obtained through 2D TEE, which was unable to characterize the defects. Three cases showed small leaks, which were completely occluded with a patent ductus arteriosus (PDA) device in two cases, and a muscular ventricular septal defect (mVSD) occluder combined with coil devices in one case. One case involved a large leak and early device embolization of the muscular VSD occluder, which was removed surgically, and demonstrated a crescent-shaped defect. One patient had two releaks 2 months subsequent to the procedure due to two new extended leaks at the tails of the crescent-shaped defect. RT 3D TEE can clearly delineate the geometries of defects in their entirety, including shape, size, and location of the defect and track canal. It would also appear that RT 3D TEE is superior to 2D TEE in the process of guiding the wire through the

  19. Transepithelial elimination of cutaneous vulval granuloma inguinale.

    PubMed

    Ramdial, P K; Kharsany, A B; Reddy, R; Chetty, R

    2000-11-01

    Transepithelial elimination (TEE), a distinct and well-known entity, is a process during which the skin eradicates undesirable or irritative dermal substances through intact epidermis or follicular epithelium by passive or active means. Although TEE is being described in an increasing number and range of pathological processes, to date, TEE of granuloma inguinale (GI) remains unrecorded in the English-language literature. The aims of this study were: 1) To appraise the light microscopic and ultrastructural morphological epidermal changes that are associated with TEE of cutaneous vulval GI; and 2) To determine the role of intra-epidermal leucocytes and histiocytes in the pathogenesis of TEE of vulval GI. This is a retrospective 9-year histopathological review of all cases diagnosed and coded as vulval granuloma inguinale in the Department of Anatomical Pathology, Nelson R. Mandela School of Medicine, University of Natal, Durban, South Africa. Ultrastructural evaluation was performed on selected cases using a Jeol transmission electron microscope. Of 53 skin biopsies from 47 patients with vulval GI, 43 were suitable for the study. The age range of patients was 15-40 years (mean age=22 years). There were eleven papular, twelve nodular, seven verrucous and thirteen ulcerative lesions. Donovan bodies within macrophages, free-lying Donovan bodies and dense aggregates of neutrophils and plasma cells were seen in the dermis of all biopsies. There was consistent overlying pseudoepitheliomatous hyperplasia. The dermal inflammatory infiltrate hugged the dermo-epidermal junction and appeared entrapped between elongated and acanthotic epidermal rete ridges and pegs. Transepidermal neutrophil microabscesses, histiocytes containing Donovan bodies and neutrophilic and histiocytic fragmentation were present. A variable number of free-lying and intra-histiocytic Donovan bodies and neutrophils were present on the surface of the epidermis. On ultrastructural investigation epidermal

  20. Weaving a Stronger Fabric for Improved Outcomes

    ERIC Educational Resources Information Center

    Lobry de Bruyn, Lisa; Prior, Julian; Lenehan, Jo

    2014-01-01

    Purpose: To explain how training and education events (TEEs) can be designed to increase the likelihood of achieving behavioural objectives. Approach: The approach combined both a quantitative review of evaluation surveys undertaken at the time of the TEE, and qualitative telephone interviews with selected attendees (2025% of the total population…

  1. Measuring Educators' Attitudes and Beliefs about Evaluation: Construct Validity and Reliability of the Teacher Evaluation Experience Scale

    ERIC Educational Resources Information Center

    Reddy, Linda A.; Dudek, Christopher M.; Kettler, Ryan J.; Kurz, Alexander; Peters, Stephanie

    2016-01-01

    This study presents the reliability and validity of the Teacher Evaluation Experience Scale--Teacher Form (TEES-T), a multidimensional measure of educators' attitudes and beliefs about teacher evaluation. Confirmatory factor analyses of data from 583 teachers were conducted on the TEES-T hypothesized five-factor model, as well as on alternative…

  2. Poor agreement between continuous measurements of energy expenditure and routinely used prediction equations in intensive care unit patients.

    PubMed

    Reid, Clare L

    2007-10-01

    A wide variation in 24h energy expenditure has been demonstrated previously in intensive care unit (ICU) patients. The accuracy of equations used to predict energy expenditure in critically ill patients is frequently compared with single or short-duration indirect calorimetry measurements, which may not represent the total energy expenditure (TEE) of these patients. To take into account this variability in energy expenditure, estimates have been compared with continuous indirect calorimetry measurements. Continuous (24h/day for 5 days) indirect calorimetry measurements were made in patients requiring mechanical ventilation for 5 days. The Harris-Benedict, Schofield and Ireton-Jones equations and the American College of Chest Physicians recommendation of 25 kcal/kg/day were used to estimate energy requirements. A total of 192 days of measurements, in 27 patients, were available for comparison with the different equations. Agreement between the equations and measured values was poor. The Harris-Benedict, Schofield and ACCP equations provided more estimates (66%, 66% and 65%, respectively) within 80% and 110% of TEE values. However, each of these equations would have resulted in clinically significant underfeeding (<80% of TEE) in 16%, 15% and 22% of patients, respectively, and overfeeding (>110% of TEE) in 18%, 19% and 13% of patients, respectively. Limits of agreement between the different equations and TEE values were unacceptably wide. Prediction equations may result in significant under or overfeeding in the clinical setting.

  3. Detection of cardiovascular shunts by transesophageal echocardiography in patients with pulmonary hypertension of unexplained cause.

    PubMed

    Chen, W J; Chen, J J; Lin, S C; Hwang, J J; Lien, W P

    1995-01-01

    The purpose of this study was to validate the usefulness of transesophageal echocardiography (TEE) in the assessment of cardiovascular shunts in patients with pulmonary hypertension (PH) of unexplained cause. Twenty-four adult patients, 16 women, 8 men; 15 to 70 years of age, with PH of unexplained cause were studied. All were examined by transthoracic echocardiography (TTE) and TEE. TTE showed the ventricular septal defect in two patients, muscular type in one and perimembranous type in the other. TEE showed the atrial septal defect in eight patients (secundum type in six and primum type in the remaining) and the patient ductus arteriosus in six patients, which were not seen by TTE. The ventricular septal defect shown by TTE was also found by TEE. Patients with a ventricular septal defect were also associated with a patient ductus arteriosus. Among 14 patients with cardiovascular lesions, nine patients displayed a pattern of bidirectional shunt, four a pure left-to-right shunt, and the remaining one a pure right-to-left shunt. All of the cardiovascular defects could be confirmed by passage of the catheter across the defect at cardiac catheterization. In light of PH, transthoracic identification of cardiovascular shunts is difficult because of the low velocity across the defect. In this study, we found that TEE was superior to TTE in detecting and localizing cardiovascular malformations in patient with PH.

  4. Comparison of ground-based and space flight energy expenditure and water turnover in middle-aged healthy male US astronauts

    NASA Technical Reports Server (NTRS)

    Lane, H. W.; Gretebeck, R. J.; Schoeller, D. A.; Davis-Street, J.; Socki, R. A.; Gibson, E. K.

    1997-01-01

    Energy requirements during space flight are poorly defined because they depend on metabolic-balance studies, food disappearance, and dietary records. Water turnover has been estimated by balance methods only. The purpose of this study was to determine energy requirements and water turnover for short-term space flights (8-14 d). Subjects were 13 male astronauts aged 36-51 y with normal body mass indexes (BMIs). Total energy expenditure (TEE) was determined during both a ground-based period and space flight and compared with the World Health Organization (WHO) calculations of energy requirements and dietary intake. TEE was not different for the ground-based and the space-flight periods (12.40 +/- 2.83 and 11.70 +/- 1.89 MJ/d, respectively), and the WHO calculation using the moderate activity correction was a good predictor of TEE during space flight. During the ground-based period, energy intake and TEE did not differ, but during space flight energy intake was significantly lower than TEE; body weight was also less at landing than before flight. Water turnover was lower during space flight than during the ground-based period (2.7 +/- 0.6 compared with 3.8 +/- 0.5 L/d), probably because of lower fluid intakes and perspiration loss during flight. This study confirmed that the WHO calculation can be used for male crew members' energy requirements during short space flights.

  5. A new therapeutic strategy for electrical cardioversion of atrial fibrillation.

    PubMed

    de Luca, I; Sorino, M; Del Salvatore, B; de Luca, L

    2001-11-01

    The conventional approach to cardioversion of atrial fibrillation includes a period of anticoagulation with oral anticoagulant therapy (OAT) extending from 3 weeks precardioversion to 4 weeks postcardioversion. The protocol of rapid anticoagulation (such as that of the ACUTE study) consists of a precardioversion transesophageal echocardiography (TEE) followed by OAT for 4 weeks. In the last few years low-molecular-weight heparins have established themselves as a safe and efficacious alternative to traditional antithrombotic therapies. The aim of this study was to demonstrate that the exclusion of thrombi by precardioversion TEE together with the exclusion of atrial stunning by a second TEE performed after 1 week, to date not suggested in the literature, could reduce to 7 days the period of pericardioversion anticoagulation. This therapy would be carried out using low-molecular-weight heparins with no need for biological monitoring and with the possibility of self-administration. We have studied 57 consecutive patients who had atrial fibrillation or flutter with a history of atrial fibrillation lasting > 48 hours. All patients received enoxaparin at a dosage of 100 IU antiXa/kg twice daily before undergoing multiplane TEE. Previous informed consent and ethical committee authorization had been obtained. Twenty-four hours following TEE, in the absence of thrombi and/or spontaneous moderate/severe echocontrast in the atrial chambers, the patients underwent electrical cardioversion and were discharged within 24 hours of sinus rhythm restoration. These patients were prescribed enoxaparin at the indicated dosage twice daily until TEE, performed in an outpatients setting 7 days following cardioversion. In the absence of thrombi and/or atrial and/or left atrial appendage stunning, OAT was terminated. Enoxaparin was associated with OAT for the following 3 weeks if any of the following signs of stunning were present: A wave inferior to the normal value for age at transmitral

  6. Body size and human energy requirements: Reduced mass-specific total energy expenditure in tall adults.

    PubMed

    Heymsfield, Steven B; Pietrobelli, Angelo

    2010-01-01

    Mammalian resting energy expenditure (REE) increases as approximately weight(0.75) while mass-specific REE scales as approximately weight(-0.25). Energy needs for replacing resting losses are thus less relative to weight (W) in large compared with small mammals, a classic observation with biological implications. Human weight scales as approximately height(2) and tall adults thus have a greater weight than their short counterparts. However, it remains unknown if mass-specific energy requirements are less in tall adults; allometric models linking total energy expenditure (TEE) and weight with height (H) are lacking. We tested the hypothesis that mass-specific energy requirements scale inversely to height in adults by evaluating TEE (doubly labeled water) data collected by the National Academy of Sciences. Activity energy expenditure (AEE) was calculated from TEE, REE (indirect calorimetry), and estimated diet-induced energy expenditure. Main analyses focused on nonmorbidly obese subjects < or =50 yrs of age with non-negative AEE values (n = 404), although results were directionally similar for all samples. Allometric models, including age as a covariate, revealed significantly (P < 0.05) greater REE, AEE, and TEE as a function of height (range H(1.5-1.7)) in both men and women. TEE/W scaled negatively to height ( approximately H(-0.7), P < 0.01) with predicted mass-specific TEE (kcal/kg/d) at +/-2 SD for US height lower in tall compared with short men (40.3 vs. 46.5) and women (37.7 vs. 42.7). REE/W also scaled negatively to height in men (P < 0.001) and women (P < 0.01). Results were generally robust across several different analytic strategies. These observations reveal previously unforeseen associations between human stature and energy requirements that have implications for modeling efforts and provide new links to mammalian biology as a whole.

  7. The influence of lidocaine topical anesthesia during transesophageal echocardiography on blood methemoglobin level and risk of methemoglobinemia.

    PubMed

    Filipiak-Strzecka, Dominika; Kasprzak, Jarosław D; Wiszniewska, Marta; Walusiak-Skorupa, Jolanta; Lipiec, Piotr

    2015-04-01

    Methemoglobinemia is a relatively rare, but potentially life-threating medical condition, which may be induced by application of topical anaesthetic agents commonly used during endoscopic procedure. The aim of our study was to assess the influence of lidocaine used prior to transesophageal echocardiography (TEE) on the blood level of methemoglobin in vivo. Additionally we attempted to establish the occurrence rate of clinically evident lidocaine-induced methemoglobinemia on the basis of data collected in our institution. We retrospectively analyzed patient records from 3,354 TEEs performed in our echocardiographic laboratory over the course of 13 years in search for clinically evident methemoglobinemia cases. Additionally, 18 consecutive patients referred for TEE were included in the prospective part of our analysis. Blood samples were tested before and 60 min after pre-TEE lidocaine anesthesia application. Information concerning concomitant conditions and pharmacotherapy were also obtained. In 3,354 patients who underwent TEE in our institution no cases of clinically evident methemoglobinemia occurred. In the prospective part of the study, none of 18 patients [16 (89 %) men, mean age 63 ± 13] was diagnosed with either clinical symptoms of methemoglobinemia or exceeded normal blood concentration of methemoglobin. Initial mean methemoglobin level was 0.5 ± 0.1 % with mild, statistically (but not clinically) significant rise to 0.6 ± 0.1 % after 60 min (p = 0.02). Among the analyzed factors only the relation between the proton pump inhibitors intake and methemoglobin blood level rise was identified as statistically relevant (p = 0.03). In adults, pre-TEE lidocaine anesthesia with recommended dosage results in significant increase in methemoglobin blood level, which however does not exceed normal values and does not result in clinically evident methemoglobinemia.

  8. Total energy expenditure, resting metabolic rate and physical activity level in free-living rural elderly men and women from Cuba, Chile and México.

    PubMed

    Alemán-Mateo, H; Salazar, G; Hernández-Triana, M; Valencia, M E

    2006-11-01

    The objective of this study was to assess total energy expenditure (TEE), resting metabolic rate (RMR) and physical activity level (PAL), and to estimate energy requirements (ERs) in free-living elderly subjects from Cuba, Chile and Mexico. Cross-sectional study designed to estimate ERs. Rural regions of Cuba, Chile and Mexico. Forty subjects >60 years old were selected to participate in this study. A dose of doubly labeled water (DLW) was administered and urine samples were collected in the following 12-14 days. From the isotopic analysis, TEE was derived. RMR was measured by indirect calorimetry. TEE in Chilean (8.8+/-1.6 MJ/day) and Cuban (8.3+/-1.3 MJ/day) elderly was not different, and was higher for the Mexican group (9.5+/-1.5 MJ/day) (P < 0.0001). RMR was not different between countries. PAL and activity energy expenditure (AEE) were only different between Chile and Mexico (P < 0.002). For the three regions, overall PALs were 1.70+/-0.16 for male and 1.62+/-0.13 for female subjects (P < 0.02), and AEE was 3.05+/-0.66 and 2.27+/-0.66 MJ/day for male and female subjects, respectively (P < 0.001). Predictive equations (MJ/day) were RMR = 1.6447 + 0.05714 x weight (kg) + 0.449 sex (male = 1; female = 0) (R2 = 0.75; SEE = 0.479) and TEE = 3.414 + 0.0795 x weight (kg) + 1.227 x sex (male = 1; female = 0) (R2 = 0.75; SEE = 0.668). There were differences in TEE and PAL owing to sex and region. The average PAL in men was higher than the PAL reported either with factorial approach or with the DLW method in elderly. Predictive ER equations based on RMR and TEE gave very similar results to calculations from the 2004 FAO/WHO/UNU report.

  9. Energy requirements of lactating women derived from doubly labeled water and milk energy output.

    PubMed

    Butte, N F; Wong, W W; Hopkinson, J M

    2001-01-01

    Instead of using an incremental approach to assess the energy requirements of lactation, a more comprehensive approach may be taken by measuring total energy expenditure (TEE), milk energy output and energy mobilization from tissue stores. The latter approach avoids assumptions regarding energetic efficiency and changes in physical activity and adiposity. The purpose of this study was threefold: to assess the energy requirements of lactation; to compare these estimates with energy requirements in the nonpregnant, nonlactating state and to test for energetic adaptations in basal metabolic rate (BMR) and physical activity during the energy-demanding process of lactation. Milk production and composition, body weight and composition, TEE, BMR and physical activity levels were measured in 24 well-nourished women during exclusive breastfeeding at 3 mo postpartum and after the cessation of breastfeeding at 18 or 24 mo postpartum. TEE was measured by the doubly labeled water method, milk production by 3-d test-weighing, milk energy by bomb calorimetry on a 24-h milk sample, body composition by dual-energy x-ray absorptiometry and BMR by room respiration calorimetry. TEE, BMR and physical activity level (physical activity level = TEE/BMR) did not differ between the lactating and nonlactating state (TEE 10.0 +/- 1.5 versus 10.6 +/- 2.1 MJ/d). Mean milk energy output was equivalent to 2.02 +/- 0.33 MJ/d. Total energy requirements were greater during lactation than afterward (12.0 +/- 1.4 versus 10.6 +/- 2.1 MJ/d, P: = 0.002). Energy mobilization from tissue stores (-0.65 +/- 0.97 MJ/d) resulted in net energy requirements during lactation of 11.4 +/- 1.8 MJ/d. Because adaptations in basal metabolism and physical activity were not evident in these well-nourished women, energy requirements during lactation were met primarily from the diet and only partially by mobilization of tissue stores.

  10. Comparison of estimates of resting energy expenditure equations in haemodialysis patients.

    PubMed

    Hung, Rachel; Sridharan, Sivakumar; Farrington, Ken; Davenport, Andrew

    2017-04-21

    Waste products of metabolism accumulate in patients with chronic kidney disease, and require clearance by haemodialysis (HD). We wished to determine whether there was an association between resting energy expenditure (REE) and total energy expenditure (TEE) in HD patients and body composition. We determined REE by recently validated equations (CKD equation) and compared REE with that estimated by standard equations for REE, and TEE calculated from patient reported physical activity, in HD patients with corresponding body composition measured by dual energy X-ray absorptiometry (DEXA) scanning. We studied 107 patients, 69 male (64.5%), mean age 62.7 ± 15.1 years. The CKD equation REE was 72.5 ± 13.3 watts (W) and TEE 83.2 ± 9.7 W. There was a strong association between REE with body surface area (BSA) (r2 = 0.80), total soft lean and fat lean tissue mass (r2 = 0.69), body mass index (BMI) (r2 = 0.34), all p<0.001. REE estimated using the modified Harris Benedict, Mifflin St. Jeor, Katch McArdle, Bernstein and Robertson equations underestimated REE compared to the CKD equation. TEE was more strongly associated with BSA (r2 = 0.51), appendicular muscle mass (r2 = 0.42), than BMI (r2 = 0.15) all p<0.001.TEE was greater for those employed (104.9 ± 10.7 vs. 83.1 ± 12.3 W, p<0.001), and with no co-morbidity (88.7 ± 14.8 vs. 82.7 ± 12.3 W, p<0.05). Standard equations underestimate REE in HD patients compared to the CKD equation. TEE was greater in those with more skeletal muscle mass, in those who were employed and in those with the least co-morbidity. More metabolically active patients may well require greater dialytic clearances.

  11. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  12. Is CHA2DS2-VASc appropriate for hyperthyroid patients with atrial fibrillation? Implications of adding a transesophageal echocardiography evaluation.

    PubMed

    de Souza, Marcus Vinicius Leitão; de Fátima Dos Santos Teixeira, Patricia; Vaisman, Mario; Xavier, Sergio Salles

    2017-02-01

    Anticoagulation remains a controversial issue among hyperthyroid patients with atrial fibrillation (AF). We aimed to evaluate the prevalence of the thrombogenic milieu (TM), detected using transesophageal echocardiography (TEE), among patients with AF related to hyperthyroidism, and to correlate these findings with the clinical embolic risk classification (CHA 2 DS 2 -VASc). CHA 2 DS 2 -VASc score, thyroid hormonal status, time since hyperthyroidism diagnosis, transthoracic echocardiography (TTE) and TEE were assessed in 47 consecutive patients aged between 18 and 65years with AF related to hyperthyroidism. The following TEE parameters defined TM: dense spontaneous echo contrast, thrombi, or left atrial appendage (LAA) blood flow velocities <0.20m/s. Non-classic TM was defined as non-dense SEC plus LAA flow velocity 0.20-0.40m/s. Pulmonary hypertension was present in 39/47 (81.4%) and TM in 22/47 (46.8%) patients. Despite a low CHA 2 DS 2 -VASc score of 0/1, 10 of 19 (52.6%) patients had a TM, whereas 16 of 28 (57.1%) patients with score ≥2 had none. The probability of having a TM did not correlate with CHA 2 DS 2 -VASc scores. On regression binary analysis, hyperthyroidism diagnosed more than 12months previous was independently associated with non-classic TM (p=0.031). Among patients younger than 65years of age with AF related to hyperthyroidism, pulmonary hypertension and TM on TEE were highly prevalent. There was no association between CHA 2 DS 2 -VASc with TEE markers of TM. Thyroid status, especially longer duration of hyperthyroidism might influence thrombogenic abnormalities. TEE adds useful information that may change antithrombotic therapy if otherwise guided solely by clinical risk classification. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Energy expenditure in professional flat jockeys using doubly labelled water during the racing season: Implications for body weight management.

    PubMed

    Wilson, George; Lucas, Daloni; Hambly, Catherine; Speakman, John R; Morton, James P; Close, Graeme L

    2018-03-01

    To formulate individualized dietary strategies for jockeys, it is vital that energy requirements are quantified. We measured total energy expenditure (TEE) over two separate weeks in spring and summer using doubly labelled water in a group of male flat jockeys (n = 8, 36.9 ± 5.7 years, 164 ± 8 cm, 54.6 ± 2.5 kg). Total energy intake (TEI) was self-recorded, as were all riding and structured exercise activity. Mean daily TEE was 10.83 (±2.3) and 10.66 (±1.76) MJ, (p = .61) respectively. Self-reported TEI were 6.03 (±1.7) and 5.37 (±1.1) MJ (p = .40), respectively, and were significantly lower than TEE (p = .01). Mean race rides were 17 (±6) and 13 (±3; p = 0.37) and horses ridden at morning exercise were 8 (±6) and 7 (±4; p = .77) respectively. Additional structured exercise was 76.25 (±95.1) and 52.5 (±80.9) min per week (p = .35), respectively. At the individual level, TEE was related to body mass and the level of non-racing physical activity, but not riding. Physical activity levels for TEE were 1.76 (±0.37) and 1.69 (±0.27; p = .59) and appear modest when compared with other athletes, and similar to age-matched non-athletes, suggesting that conventional sport-specific nutritional recommendations do not appear applicable. The large discrepancy between TEE and TEI suggests significant under reporting of dietary intake. These data now provide an appropriate framework from which to formulate jockey nutritional guidelines to promote the ability to achieve the daily weight target and improve athlete welfare.

  14. The Validity of US Nutritional Surveillance: USDA's Loss-Adjusted Food Availability Data Series 1971-2010

    PubMed Central

    Archer, Edward; Thomas, Diana M.; McDonald, Samantha M.; Pavela, Gregory; Lavie, Carl J.; Hill, James O.; Blair, Steven N.

    2016-01-01

    The purpose of this study was to examine the validity of the 1971-2010 United States Department of Agriculture's (USDA's) loss-adjusted food availability (LAFA) per capita caloric consumption estimates. Estimated total daily energy expenditure (TEE) was calculated for nationally representative samples of US adults, 20-74 years, using the Institute of Medicine's predictive equations with “low-active” (TEE L-ACT) and “sedentary” (TEE SED) physical activity values. TEE estimates were subtracted from LAFA estimates to create disparity values (kcal/d). A validated mathematical model was applied to calculate expected weight change in reference individuals resulting from the disparity. From 1971-2010, the disparity between LAFA and TEE L-ACT varied by 394 kcal/d—(P < 0.001), from −205 kcal/d (95% CI: −214, −196) to +189 kcal/d (95% CI: 168, 209). The disparity between LAFA and TEE SED varied by 412 kcal/d (P < 0.001), from −84 kcal/d (95% CI: −93, −76) to +328 kcal/d (95% CI: 309, 348). Our model suggests that if LAFA estimates were actually consumed, reference individuals would have lost ∼1-4 kg/y from 1971-1980 (an accumulated loss of ∼ 12 to ∼36kg), and gained ∼ 3-7 kg/y from 1988-2010 (an accumulated gain of ∼42 to ∼98 kg). These estimates differed from the actual measured increments of 10 kg and 9 kg in reference men and women, respectively, over the 39-year period. The USDA LAFA data provided inconsistent, divergent estimates of per capita caloric consumption over its 39-year history. The large, variable misestimation suggests that the USDA LAFA per capita caloric intake estimates lack validity and should not be used to inform public policy. PMID:27914522

  15. Clinical Management of Staphylococcus aureus Bacteremia

    PubMed Central

    Holland, Thomas L.; Arnold, Christopher; Fowler, Vance G.

    2014-01-01

    Importance Several management strategies may improve outcomes in patients with Staphylococcus aureus bacteremia (SAB). The strength of evidence supporting these management strategies, however, varies widely. Objective To perform a systematic review of the evidence for two unresolved questions involving management strategies for SAB: 1) is transesophageal echocardiography (TEE) necessary in all cases of SAB; and 2) what is the optimal antibiotic therapy for methicillin resistant Staphylococcus aureus (MRSA) bacteremia? Evidence acquisition A PubMed search from inception through May 2014 was performed to find studies that addressed the role of TEE in SAB. A second search of PubMed, EMBASE, and The Cochrane Library from 1/1/1990 to 5/28/2014 was performed to find studies that addressed antibiotic treatment of MRSA bacteremia. Studies that reported outcomes of systemic antibiotic therapy for MRSA bacteremia were included. All searches were augmented by review of bibliographic references from included studies. The quality of evidence was assessed using the GRADE system by consensus of independent evaluations by at least two authors. Results In 9 studies with a total of 3513 patients, use of TEE was associated with higher rates of diagnosis of endocarditis (14–25%) when compared with TTE (2–14%). Five studies proposed criteria to identify patients in whom TEE might safely be avoided. Only one high-quality trial of antibiotic therapy for MRSA bacteremia was identified from the 83 studies considered. Conclusions and relevance Most contemporary management strategies for SAB are based upon low quality evidence. TEE is indicated in most patients with SAB. It may be possible to identify a subset of SAB patients for whom TEE can be safely avoided. Vancomycin and daptomycin are the first-line antibiotic choices for MRSA bacteremia. Well-designed studies to address the management of SAB are desperately needed. PMID:25268440

  16. Transesophageal echocardiography: first-line imaging for aortic diseases

    NASA Technical Reports Server (NTRS)

    Yalcin, F.; Thomas, J. D.; Homa, D.; Flachskampf, F. A.

    2000-01-01

    Transesophageal echocardiography (TEE) is now commonly used to evaluate the thoracic aorta, because it is widely available and provides high-resolution images and flow information by Doppler. This article reviews the essential features on TEE of acute and chronic aortic diseases, such as aortic dissection, aneurysm, and atherosclerosis, and discusses its strengths, weaknesses, and indications.

  17. Roles of Transesophageal Echocardiography and Cardiac Computed Tomography for Evaluation of Left Atrial Thrombus and Associated Pathology: A Review and Critical Analysis.

    PubMed

    Pathan, Faraz; Hecht, Harvey; Narula, Jagat; Marwick, Thomas H

    2018-04-01

    Evaluation of the left atrium and left atrial appendage for the presence of thrombus prior to cardioversion and pulmonary vein isolation, and of the entire heart for embolic sources in the setting of cryptogenic stroke, has long been standard medical care. Guidelines have uniformly recommended transesophageal echocardiography (TEE) to accomplish these goals. In recent years, computed tomographic angiography has demonstrated diagnostic accuracy similar to that of TEE for the detection of thrombus. Analysis of the pertinent data and relative merits of the 2 technologies leads to the conclusions that: 1) both modalities have some unique, nonoverlapping capabilities that may dictate their use in specific situations; 2) computed tomographic angiography is a reasonable alternative to TEE when the primary aim is to exclude left atrial and left atrial appendage thrombus and in patients in whom the risks associated with TEE outweigh the benefits; and 3) both options should be discussed with the patient in the setting of shared decision making. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Multi-point estimation of total energy expenditure: a comparison between zinc-reduction and platinum-equilibration methodologies.

    PubMed

    Sonko, Bakary J; Miller, Leland V; Jones, Richard H; Donnelly, Joseph E; Jacobsen, Dennis J; Hill, James O; Fennessey, Paul V

    2003-12-15

    Reducing water to hydrogen gas by zinc or uranium metal for determining D/H ratio is both tedious and time consuming. This has forced most energy metabolism investigators to use the "two-point" technique instead of the "Multi-point" technique for estimating total energy expenditure (TEE). Recently, we purchased a new platinum (Pt)-equilibration system that significantly reduces both time and labor required for D/H ratio determination. In this study, we compared TEE obtained from nine overweight but healthy subjects, estimated using the traditional Zn-reduction method to that obtained from the new Pt-equilibration system. Rate constants, pool spaces, and CO2 production rates obtained from use of the two methodologies were not significantly different. Correlation analysis demonstrated that TEEs estimated using the two methods were significantly correlated (r=0.925, p=0.0001). Sample equilibration time was reduced by 66% compared to those of similar methods. The data demonstrated that the Zn-reduction method could be replaced by the Pt-equilibration method when TEE was estimated using the "Multi-Point" technique. Furthermore, D equilibration time was significantly reduced.

  19. Esophageal Perforation After Transesophageal Echocardiogram.

    PubMed

    Shapira, Michael Y.; Hirshberg, Boaz; Agid, Ronit; Zuckerman, Elena; Caraco, Yoseph

    1999-02-01

    Esophageal rupture after transesophageal echocardiogram (TEE) is a rare but life-threatening complication. Risk factors for perforation include spasm or hypertrophy of the cricopharyngeal sphincter, cervical arthritis, forward and left lateral bending of the distal esophagus, and esophageal disease such as inflammation or neoplasm. We present the case of a 80-year-old woman who developed perforation of her esophagus after TEE. Prior irradiation to the chest due to treatment for breast cancer and subsequent fibrosis probably contributed to this complication. Physicians referring patients for a TEE and physicians performing this procedure should be aware for the risk of perforation. The identification of risk factors and gentle maneuvering of the probe may prevent this severe, life-threatening complication.

  20. Propellers: Why Do They Work?

    ERIC Educational Resources Information Center

    Mitts, Charles R.

    2013-01-01

    In order for technology and engineering education (T&EE) students to meet the design challenges of this century, T&EE teachers will need to deepen their content pedagogy in the areas of science and math. This raises the question: Will the need to deepen content pedagogy initiate a process of change that transforms technology and engineering…

  1. Partial anomalous pulmonary venous connection: diagnosis by transesophageal echocardiography.

    PubMed

    Ammash, N M; Seward, J B; Warnes, C A; Connolly, H M; O'Leary, P W; Danielson, G K

    1997-05-01

    This study sought to demonstrate that with proper technique, identification of the normal and abnormal pulmonary venous connection can be made with confidence using transesophageal echocardiography (TEE). Partial anomalous pulmonary venous connection (PAPVC) is an uncommon congenital anomaly whose diagnosis has classically been made using angiography. We performed a retrospective review of all patients of all ages with PAPVC diagnosed at the Mayo Clinic who had undergone TEE because of either right ventricular volume overload or suspected intracardiac shunting by transthoracic echocardiography or intraoperatively. A total of 66 PAPVCs were detected in 43 patients (1.5/patient); in 2 additional patients, TEE suggested, but did not diagnose, PAPVCs. Shortness of breath was the most common presenting symptom (42.2%), followed by heart murmur and supraventricular tachycardia. Right-sided anomalous veins were identified in 35 patients (81.4%), left-sided in 7 (16.3%) and bilateral in 1 (2.3%). There was a single anomalous connecting vein in 23 patients (53.5%), two in 18 (41.9%), three in 1 (2.3%) and four in 1 (2.3%). The connecting site was the superior vena cava (SVC) in 39 veins (59.1%), right atrial-SVC junction in 6 (9.1%), right atrium in 8 (12.1%), inferior vena cava in 1 (1.5%) and the coronary sinus in 2 (3.0%). Ten anomalous left pulmonary veins were connected by a vertical vein to the innominate vein (15.1%). Sinus venosus atrial septal defect (ASD) was the most common associated anomaly in 22 patients (49%), followed by ostium secundum ASD in 6 and patent foramen ovale in 4. Fifteen patients had an intact atrial septum. Thirty-one patients (68.8%) underwent surgical repair. PAPVC was confirmed in all patients, including the two whose TEE results were suggestive of PAPVC. All 49 PAPVCs detected by TEE preoperatively were confirmed at the time of operation. TEE is highly diagnostic for PAPVC and can obviate angiography. Accurate anatomic diagnosis may

  2. Impact of electrocardiogram-gated multi-slice computed tomography-based aortic annular measurement in the evaluation of paravalvular leakage following transcatheter aortic valve replacement: the efficacy of the OverSized AortiC Annular ratio (OSACA ratio) in TAVR.

    PubMed

    Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki

    2013-07-01

    Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.

  3. Circulating microparticles and the risk of thromboembolic events in Egyptian beta thalassemia patients.

    PubMed

    Youssry, Ilham; Soliman, Nohair; Ghamrawy, Mona; Samy, Rania Mohamed; Nasr, Amal; Abdel Mohsen, Mohamed; ElShahaat, Mohamed; Bou Fakhredin, Rayan; Taher, Ali

    2017-04-01

    The presence of elevated numbers of circulating microparticles (MPs) has been hypothesized to be responsible for the occurrence of thromboembolic events (TEEs) in thalassemic patients. Our aim is to evaluate the presence and the thrombotic risk of circulating MPs in thalassemia patients and to determine the difference in MPs between β-thalassemia major (β-TM) and thalassemia intermedia (TI). The percentage of the annexin-labeled MPs, platelet-derived MPs (PMPs), erythrocyte-derived MPs (RMPs), and endothelial-derived MPs (EMPs) was measured by flow cytometry, in 87 thalassemia patients (39 β-TM and 48 TI). By multiple regression analysis, we then assessed the various independent risk factors for the occurrence of TEE. The thalassemic patients who experienced TEE had a significantly higher platelet count, higher percentage of annexin-labeled MPs, and higher percentage of PMPs (p value = 0.014, 0.003, and 0.014, respectively). There was no significant difference between β-TM and TI patients at the level of any of the studied MPs. The predictive risk factors for TEE in thalassemic patients were splenectomy, total and direct bilirubin, the RMPs, and the EMPs (OR = 10.07 (CI = 3.7-27.1), 4.3 (CI = 2.1-8.7), 1.4 (CI = 1.5-6.2), 1.6 (CI = 1.1-2.2), 3.0 (CI = 1.9-4.9), respectively). In conclusion, the elevated numbers of circulating MPs is a risk factor for the TEE in thalassemia patients.

  4. Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models.

    PubMed

    Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi

    2017-12-08

    This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.

  5. Feasibility of the Use of Transesophageal Echocardiography as a Surface Probe for Puncturing and Catheterization of the Internal Jugular Vein: A Randomized Controlled Pilot Study.

    PubMed

    Teng, Yi; Ou, Mengchan; Yu, Hai

    2018-02-01

    To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair.

    PubMed

    Li, Feng P; Rajchl, Martin; Moore, John; Peters, Terry M

    2015-01-01

    To develop and validate a real-time mitral valve annulus (MVA) tracking approach based on biplane transesophageal echocardiogram (TEE) data and magnetic tracking systems (MTS) to be used in minimally invasive off-pump beating heart mitral valve repair (MVR). The authors' guidance system consists of three major components: TEE, magnetic tracking system, and an image guidance software platform. TEE provides real-time intraoperative images to show the cardiac motion and intracardiac surgical tools. The magnetic tracking system tracks the TEE probe and the surgical tools. The software platform integrates the TEE image planes and the virtual model of the tools and the MVA model on the screen. The authors' MVA tracking approach, which aims to update the MVA model in near real-time, comprises of three steps: image based gating, predictive reinitialization, and registration based MVA tracking. The image based gating step uses a small patch centered at each MVA point in the TEE images to identify images at optimal cardiac phases for updating the position of the MVA. The predictive reinitialization step uses the position and orientation of the TEE probe provided by the magnetic tracking system to predict the position of the MVA points in the TEE images and uses them for the initialization of the registration component. The registration based MVA tracking step aims to locate the MVA points in the images selected by the image based gating component by performing image based registration. The validation of the MVA tracking approach was performed in a phantom study and a retrospective study on porcine data. In the phantom study, controlled translations were applied to the phantom and the tracked MVA was compared to its "true" position estimated based on a magnetic sensor attached to the phantom. The MVA tracking accuracy was 1.29 ± 0.58 mm when the translation distance is about 1 cm, and increased to 2.85 ± 1.19 mm when the translation distance is about 3 cm. In the study on

  7. Guidelines for Conducting a Training Effectiveness Evaluation (TEE). Volume 1. TEE Evaluator’s Handbook

    DTIC Science & Technology

    1985-02-01

    by drawing prerequisite lines, the relationships between all subordinate skills and knowledges and the terminal objective. Thus, for purposes of...functions, tasks, or skills below it, rate the relationship of the performances shown in the superordinate box to those in the subordinate boxes...A useful format for displaying performance relationships between team functions and subordinate tasks or communication and coordination skills

  8. Research on Synchronous Coordination Development of Tourism-Economy-Environment System in Qinghai Section of Silk Road

    NASA Astrophysics Data System (ADS)

    Xue, Huaju

    2018-01-01

    Using coupling theory in physics, the paper analyzed the relationship of coordinated development of tourism-economy-environment system (abbr. TEES) in Qinghai. Results showed the comprehensive evaluation of Qinghai TEES has been improved greatly from 2000 to 2014. However, coupling degree has still been in the running-in stage and coordination degree only arrives at the primary coordination level, the development of economy and tourism has exceeded the threshold of ecological environment after 2008, and the ecological environment has become the bottleneck restricting the further improvement of coupling coordination. In the future, Qinghai must change its mode of development and focus on industrial upgrading and transformation so as to promote the harmonious and sustainable development of TEES in the Silk Road.

  9. Acute Severe Aortic Regurgitation: Imaging with Pathological Correlation.

    PubMed

    Janardhanan, Rajesh; Pasha, Ahmed Khurshid

    2016-03-01

    Acute aortic regurgitation (AR) is an important finding associated with a wide variety of disease processes. Its timely diagnosis is of utmost importance. Delay in diagnosis could prove fatal. We describe a case of acute severe AR that was timely diagnosed using real time three-dimensional (3D) transesophageal echocardiogram (3D TEE). Not only did it diagnose but also the images obtained by 3D TEE clearly matched with the pathologic specimen. Using this sophisticated imaging modality that is mostly available at the tertiary centers helped in the timely diagnosis, which lead to the optimal management saving his life. Echocardiography and especially 3D TEE can diagnose AR very accurately. Surgical intervention is the definitive treatment but medical therapy is utilized to stabilize the patient initially.

  10. Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

    NASA Technical Reports Server (NTRS)

    Klotzsch, Christof; Janben, Gerhard; Berlit, Peter

    1994-01-01

    Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

  11. Real-time 3D transesophageal echocardiography-guided closure of a complicated patent ductus arteriosus in a dog.

    PubMed

    Doocy, K R; Nelson, D A; Saunders, A B

    2017-06-01

    Advanced imaging modalities are becoming more widely available in veterinary cardiology, including the use of transesophageal echocardiography (TEE) during occlusion of patent ductus arteriosus (PDA) in dogs. The dog in this report had a complex history of attempted ligation and a large PDA that initially precluded device placement thereby limiting the options for PDA closure. Following a second thoracotomy and partial ligation, the morphology of the PDA was altered and device occlusion was an option. Angiographic assessment of the PDA was limited by the presence of hemoclips, and the direction of ductal flow related to the change in anatomy following ligature placement. Intra-operative TEE, in particular real-time three-dimensional imaging, was pivotal for assessing the PDA morphology, monitoring during the procedure, selecting the device size, and confirming device placement. The TEE images increased operator confidence that the size and location of the device were appropriate before release despite the unusual position. This report highlights the benefit of intra-operative TEE, in particular real-time three-dimensional imaging, for successful PDA occlusion in a complicated case. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Affordable measurement of human total energy expenditure and body composition using one-tenth dose doubly labelled water.

    PubMed

    Mann, D V; Ho, C S; Critchley, L; Fok, B S P; Pang, E W H; Lam, C W K; Hjelm, N M

    2007-05-01

    The doubly labelled water (DLW) method is the technique of choice for measurement of free-living total energy expenditure (TEE) in humans. A major constraint on the clinical applicability of the method has been the expense of the (18)O isotope. We have used a reduced-dose (one-tenth of the currently recommended standard dose) of DLW for the measurement of TEE and body composition in nine healthy adult male volunteers. TEE measured by reduced-dose DLW was positively correlated with resting energy expenditure measured by metabolic cart (r=0.87, P<0.01). Isotope-derived fat mass and body mass index were strongly correlated (r=0.86, P<0.01). In four subjects in whom we performed a complementary evaluation using standard-dose isotope enrichment, the TEE measurements were satisfactorily comparable (mean+/-s.d.: reduced dose 2586+/-155 kcal/day vs standard dose 2843+/-321 kcal/day; mean difference 257+/-265 kcal/day). These data indicate that DLW measurements of human energy expenditure and body composition can be performed at a substantially reduced dose (and cost) of isotope enrichment than is currently employed.

  13. Experimental testing and modeling analysis of solute mixing at water distribution pipe junctions.

    PubMed

    Shao, Yu; Jeffrey Yang, Y; Jiang, Lijie; Yu, Tingchao; Shen, Cheng

    2014-06-01

    Flow dynamics at a pipe junction controls particle trajectories, solute mixing and concentrations in downstream pipes. The effect can lead to different outcomes of water quality modeling and, hence, drinking water management in a distribution network. Here we have investigated solute mixing behavior in pipe junctions of five hydraulic types, for which flow distribution factors and analytical equations for network modeling are proposed. First, based on experiments, the degree of mixing at a cross is found to be a function of flow momentum ratio that defines a junction flow distribution pattern and the degree of departure from complete mixing. Corresponding analytical solutions are also validated using computational-fluid-dynamics (CFD) simulations. Second, the analytical mixing model is further extended to double-Tee junctions. Correspondingly the flow distribution factor is modified to account for hydraulic departure from a cross configuration. For a double-Tee(A) junction, CFD simulations show that the solute mixing depends on flow momentum ratio and connection pipe length, whereas the mixing at double-Tee(B) is well represented by two independent single-Tee junctions with a potential water stagnation zone in between. Notably, double-Tee junctions differ significantly from a cross in solute mixing and transport. However, it is noted that these pipe connections are widely, but incorrectly, simplified as cross junctions of assumed complete solute mixing in network skeletonization and water quality modeling. For the studied pipe junction types, analytical solutions are proposed to characterize the incomplete mixing and hence may allow better water quality simulation in a distribution network. Published by Elsevier Ltd.

  14. Effect of Diet Composition on Energy Expenditure during Weight Loss: The POUNDS LOST Study

    PubMed Central

    Bray, George A.; Smith, Steven R.; DeJonge, Lilian; de Souza, Russell; Rood, Jennifer; Champagne, Catherine M.; Laranjo, Nancy; Carey, Vincent; Obarzanek, Eva; Loria, Catherine M.; Anton, Stephen D.; Ryan, Donna H.; Greenway, Frank L.; Williamson, Donald; Sacks, Frank M.

    2011-01-01

    Background Weight loss reduces energy expenditure, but the contribution of different macronutrients to this change is unclear. Hypothesis We tested the hypothesis that macronutrient composition of the diet might affect the partitioning of energy expenditure during weight loss. Design A sub-study of 99 participants from the POUNDS LOST trial had total energy expenditure (TEE) measured by doubly labeled water and resting energy expenditure (REE) measured by indirect calorimetry at baseline and repeated at 6 months in 89 participants. Participants were randomly assigned to one of 4 diets with either 15% or 25% protein and 20% or 40% fat. Results TEE and REE were positively correlated with each other and with fat free mass and body fat, at baseline and 6 months. The average weight loss of 8.1±0.65 kg (LSmean±SE) reduced TEE by 120±56 kcal/d and REE by 136±18 kcal/d. A greater weight loss at 6 months was associated with a greater decrease in TEE and REE. Participants eating the high fat diet lost significantly more fat free mass (1.52±0.55 kg) than the low fat diet group (p<0.05). Participants eating the low fat diet had significantly higher measures of physical activity than the high fat group. Conclusion A greater weight loss was associated with a larger decrease in both TEE and REE. The low fat diet was associated with significant changes in fat free body mass and energy expenditure from physical activity compared to the high fat diet. PMID:21946707

  15. Role of P-selectin in thromboembolic events in patients with cancer.

    PubMed

    Fernandes, Lúcio Flávio Barbour; Fregnani, José Humberto T G; Strunz, Célia Maria Cássaro; de Andrade Ramos Nogueira, Adriana; Longatto-Filho, Adhemar

    2018-01-01

    The objective of the present study was to evaluate the role of P-selectin in patients with cancer with suspected thromboembolic events (TEEs). Patients with cancer have a four times greater risk of developing TEEs. P-selectin is a glycoprotein that has the function of facilitating the interaction (adhesion) of leukocytes with the endothelium, or with platelets. There is a well-defined relationship between P-selectin and thrombosis; however, it is likely that the cut-off value of P-selectin for patients with cancer should be considered differently from that of the general population. In the present report, a prospective cross-sectional study was performed with patients of the Cancer Hospital of Barretos who were suspected of having TEEs. Among the 178 study participants, 167 (93.82%) were suspected of having deep vein thrombosis, while 59 of them (35.33%) were confirmed as such; and 11 (6.18%) were suspected of having pulmonary thromboembolism, while 3 of them were confirmed as such (27.69%). The mean results obtained were: P-selectin, 25.37 ng/ml; and D-dimer, 2,181.22 ng/ml. The P-selectin levels averaged 33.60 ng/ml with the confirmed TEE group compared with 20.40 ng/ml with the unconfirmed TEE group, with a standard deviation of 23.35 compared with 6.92 (P<0.001); and the level of D-dimer was 4,615.38 ng/ml compared with 977.52 ng/ml, with a standard deviation of 6,460.54 compared with 2,145.50 (P<0.001). Multiple logistic regression adjusted for distant metastases and the Eastern Cooperative Oncology Group (ECOG) score (2,3 and 4) were constructed. The cut-off value of P-selectin for patients with cancer was identified to be different from that reported in the literature for the general population, and the models using D-dimer and P-selectin therefore have been demonstrated to be a potentially useful tool to be used in a panel of tests to predict TEEs, either independently or in a prediction score.

  16. Self-monitoring of dietary intake by young women: online food records completed on computer or smartphone are as accurate as paper-based food records but more acceptable.

    PubMed

    Hutchesson, Melinda J; Rollo, Megan E; Callister, Robin; Collins, Clare E

    2015-01-01

    Adherence and accuracy of self-monitoring of dietary intake influences success in weight management interventions. Information technologies such as computers and smartphones have the potential to improve adherence and accuracy by reducing the burden associated with monitoring dietary intake using traditional paper-based food records. We evaluated the acceptability and accuracy of three different 7-day food record methods (online accessed via computer, online accessed via smartphone, and paper-based). Young women (N=18; aged 23.4±2.9 years; body mass index 24.0±2.2) completed the three 7-day food records in random order with 7-day washout periods between each method. Total energy expenditure (TEE) was derived from resting energy expenditure (REE) measured by indirect calorimetry and physical activity level (PAL) derived from accelerometers (TEE=REE×PAL). Accuracy of the three methods was assessed by calculating absolute (energy intake [EI]-TEE) and percentage difference (EI/TEE×100) between self-reported EI and TEE. Acceptability was assessed via questionnaire. Mean±standard deviation TEE was 2,185±302 kcal/day and EI was 1,729±249 kcal/day, 1,675±287kcal/day, and 1,682±352 kcal/day for computer, smartphone, and paper records, respectively. There were no significant differences between absolute and percentage differences between EI and TEE for the three methods: computer, -510±389 kcal/day (78%); smartphone, -456±372 kcal/day (80%); and paper, -503±513 kcal/day (79%). Half of participants (n=9) preferred computer recording, 44.4% preferred smartphone, and 5.6% preferred paper-based records. Most participants (89%) least preferred the paper-based record. Because online food records completed on either computer or smartphone were as accurate as paper-based records but more acceptable to young women, they should be considered when self-monitoring of intake is recommended to young women. Copyright © 2015 Academy of Nutrition and Dietetics. Published by

  17. Compensatory Changes in Energy Balance Regulation over One Athletic Season.

    PubMed

    Silva, Analiza M; Matias, Catarina N; Santos, Diana A; Thomas, Diana; Bosy-Westphal, Anja; MüLLER, Manfred J; Heymsfield, Steven B; Sardinha, LUíS B

    2017-06-01

    Mechanisms in energy balance (EB) regulation may include compensatory changes in energy intake (EI) and metabolic adaption (MA), but information is unavailable in athletes who often change EB components. We aim to investigate EB regulation compensatory mechanisms over one athletic season. Fifty-seven athletes (39 males/18 females; handball, volleyball, basketball, triathlon, and swimming) were evaluated from the beginning to the competitive phase of the season. Resting and total energy expenditure (REE and TEE, respectively) were assessed by indirect calorimetry and doubly labeled water, respectively, and physical activity energy expenditure was determined as TEE - 0.1(TEE) - REE. Fat mass (FM) and fat-free mass (FFM) were evaluated by dual-energy x-ray absorptiometry and changed body energy stores was determined by 1.0(ΔFFM/Δtime) + 9.5(ΔFM/Δtime). EI was derived as TEE + EB. REE was predicted from baseline FFM, FM, sex, and sports. %MA was calculated as 100(measured REE/predicted REE-1) and MA (kcal) as %MA/100 multiplied by baseline measured REE. Average EI minus average physical activity energy expenditure was computed as a proxy of average energy availability, assuming that a constant nonexercise EE occurred over the season. Body mass increased by 0.8 ± 2.5 kg (P < 0.05), but a large individual variability was found ranging from -6.1 to 5.2 kg. The TEE raise (16.8% ± 11.7%) was compensated by an increase EI change (16.3% ± 12.0%) for the whole group (P < 0.05). MA was found in triathletes, sparing 128 ± 168 kcal·d, and basketball players, dissipating 168 ± 205 kcal·d (P < 0.05). MA was associated (P < 0.05) with EB and energy availability (r = 0.356 and r = 0.0644, respectively). TEE increased over the season without relevant mean changes in weight, suggesting that EI compensation likely occurred. The thrifty or spendthrift phenotypes observed among sports and the demanding workloads these athletes are exposed to highlight the need for sport

  18. Energy expenditure in adults living in developing compared with industrialized countries: a meta-analysis of doubly labeled water studies123

    PubMed Central

    Dugas, Lara R; Harders, Regina; Merrill, Sarah; Ebersole, Kara; Shoham, David A; Rush, Elaine C; Assah, Felix K; Forrester, Terrence; Durazo-Arvizu, Ramon A; Luke, Amy

    2011-01-01

    Background: There is an assumption that people in developing countries have a higher total energy expenditure (TEE) and physical activity level (PAL) than do people in developed nations, but few objective data for this assertion exist. Objective: We conducted a meta-analysis of TEE and PAL by using data from countries that have a low or middle human development index (HDI) compared with those with a high HDI to better understand how energy-expenditure variables are associated with development status and population differences in body size. Design: We performed a literature search for studies in which energy expenditure was measured by using doubly labeled water. Mean data on age, weight, body mass index (BMI; in kg/m2), TEE, and PAL were extracted, and HDI status was assessed. Pooled estimates of the mean effect by sex were obtained, and the extent to which age, weight, HDI status, and year of publication explained heterogeneity was assessed. Results: A total of 98 studies (14 studies from low- or middle-HDI countries) that represented 183 cohorts and 4972 individuals were included. Mean (±SE) BMI was lower in countries with a low or middle HDI than in those with a high HDI for both men and women (22.7 ± 1.0 compared with 26.0 ± 0.7, respectively, in men and 24.3 ± 0.7 compared with 26.6 ± 0.4, respectively, in women). In meta-regression models, there was an inverse association of age (P < 0.001) and a positive association of weight (P < 0.001) with TEE for both sexes; there was an association of age only in men with PAL (P < 0.001). There was no association of HDI status with either TEE or PAL. Conclusion: TEE adjusted for weight and age or PAL did not differ significantly between developing and industrialized countries, which calls into question the role of energy expenditure in the cause of obesity at the population level. PMID:21159791

  19. Acute Severe Aortic Regurgitation: Imaging with Pathological Correlation

    PubMed Central

    Janardhanan, Rajesh; Pasha, Ahmed Khurshid

    2016-01-01

    Context: Acute aortic regurgitation (AR) is an important finding associated with a wide variety of disease processes. Its timely diagnosis is of utmost importance. Delay in diagnosis could prove fatal. Case Report: We describe a case of acute severe AR that was timely diagnosed using real time three-dimensional (3D) transesophageal echocardiogram (3D TEE). Not only did it diagnose but also the images obtained by 3D TEE clearly matched with the pathologic specimen. Using this sophisticated imaging modality that is mostly available at the tertiary centers helped in the timely diagnosis, which lead to the optimal management saving his life. Conclusion: Echocardiography and especially 3D TEE can diagnose AR very accurately. Surgical intervention is the definitive treatment but medical therapy is utilized to stabilize the patient initially. PMID:27114975

  20. The Role of Basal Forebrain in Rat Somatosensory Cortex: Impact on Cholinergic Innervation, Sensory Information Processing, and Tactile Discrimination

    DTIC Science & Technology

    1993-05-28

    1993 Dissertation and Abstract Approved: Commit tee Chairperson . ,a..w ember ~tee Member tli:u., ;2 9" PQ3 bate Date bate The author...1982; Mesulam et al., 1983; Rye et al., 1984; Saper, 1984). I will refer to the region of the basal forebrain that supplies cholinergic innervation to...topographical organization has been observed for cholinergic projection patterns, with more rostral and medial basal forebrain cell groups supplying

  1. Film Piracy, Organized Crime, and Terrorism

    DTIC Science & Technology

    2009-01-01

    appointed Malaysian Inspector General of Police renewed efforts to fight organized crime by dedicating more resources to Operation Copperhead, originally...opera- tions in Kuala Lumpur.104 The Malaysian government singled out the dragonhead of the Ang Bin Hoey triad, Tee Yam (aka Khoo Tee Yam), as its...interviews with Serious Crime Division of Malaysian Police, August 1, 2005. Getting Down to Cases: Organized Crime and Film Piracy 71 in

  2. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    PubMed

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  3. Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing.

    PubMed

    Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria

    2018-01-01

    Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (<3,025 arbitrary units) compared with patients with high AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  4. Left atrial thrombus and dense spontaneous echocardiographic contrast in patients on continuous direct oral anticoagulant therapy undergoing catheter ablation of atrial fibrillation: Comparison of dabigatran, rivaroxaban, and apixaban.

    PubMed

    Wu, Michael; Gabriels, James; Khan, Mohammad; Shaban, Nada; D'Amato, Salvatore; Liu, Christopher F; Markowitz, Steven M; Ip, James E; Thomas, George; Singh, Parmanand; Lerman, Bruce; Patel, Apoor; Cheung, Jim W

    2018-04-01

    Left atrial thrombus (LAT) and dense spontaneous echocardiographic contrast (SEC) detected by transesophageal echocardiography (TEE) in patients on continuous direct oral anticoagulants (DOAC) therapy before catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL) have been described. We sought to compare rates of TEE-detected LAT and dense SEC among patients taking different DOACs. We evaluated 609 consecutive patients from 3 tertiary hospitals (median age 65 years; interquartile range 58-71 years; 436 (72%) men) who were on ≥4 weeks of continuous DOAC therapy (dabigatran, n = 166 [27%]; rivaroxaban, n = 257 [42%]; or apixaban, n = 186 [31%]) undergoing TEE before catheter ablation of AF/AFL. Demographic, clinical, and TEE data were collected for each patient. Despite ≥4 weeks of continuous DOAC therapy, 17 patients (2.8%) had LAT and 15 patients (2.5%) had dense SEC detected by TEE. The rates of LAT were 3.0%, 3.5%, and 1.6% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .482). The rates of dense SEC were 1.2%, 3.5%, and 2.2% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .299). Congestive heart failure (odds ratio 4.4; 95% confidence interval 1.6-12; P = .003) and moderate/severe left atrial enlargement (odds ratio 3.1; 95% confidence interval 1.1-8.6; P = .026) were independent predictors of LAT. In this study, ∼3% of patients on continuous DOAC therapy had LAT detected before catheter ablation of AF/AFL. Specific DOAC therapy did not significantly affect the rates of LAT detection. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Under-reporting of food intake and body fatness in independent older people: a doubly labelled water study.

    PubMed

    Pfrimer, Karina; Vilela, Mariana; Resende, Cristina Maria; Scagliusi, Fernanda Baeza; Marchini, Julio Sergio; Lima, Nereida K C; Moriguti, Julio Cesar; Ferriolli, Eduardo

    2015-01-01

    there are no accurate methods for the assessment of food intake in older populations, under-reporting of intake being highly prevalent. There is controversy about which dietary assessment method and what person's characteristics are associated with greater under-reporting rates. to assess the correlation between under-reporting of energy intake (EI) and different percentages of body fat in independent older people. cross-sectional study. area assisted by the Family Health Program of the Ribeirão Preto Medical School, University of São Paulo, Brazil. one hundred volunteers aged 60-70 years. all volunteers had their body composition assessed by dual-energy x-ray absorptiometry. In second phase, 41 volunteers were evaluated, representing the four quartiles of fat percentage. Total energy expenditure (TEE) was measured by the doubly labelled water method, and EI was assessed by 24-h recalls and a food frequency questionnaire (FFQ). TEE and EI values, EI-to-TEE ratios and EI-TEE values were compared. TEE was 2,220 ± 601 kcal, while the EI was 1,919 ± 602 kcal (24-h recall) and 2,119 ± 670 kcal (FFQ). The proportion of under-reporters was 31 and 40.5%, respectively. Under-reporting was more frequent in subjects with higher percentage of body fat and in females (P < 0.05). under-reporting was more frequent among older persons with higher percentage of body fat in both methods of assessment of food intake. Older persons follow the same profile of under-reporting as younger adults. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. 3D-printed pediatric endoscopic ear surgery simulator for surgical training.

    PubMed

    Barber, Samuel R; Kozin, Elliott D; Dedmon, Matthew; Lin, Brian M; Lee, Kyuwon; Sinha, Sumi; Black, Nicole; Remenschneider, Aaron K; Lee, Daniel J

    2016-11-01

    Surgical simulators are designed to improve operative skills and patient safety. Transcanal Endoscopic Ear Surgery (TEES) is a relatively new surgical approach with a slow learning curve due to one-handed dissection. A reusable and customizable 3-dimensional (3D)-printed endoscopic ear surgery simulator may facilitate the development of surgical skills with high fidelity and low cost. Herein, we aim to design, fabricate, and test a low-cost and reusable 3D-printed TEES simulator. The TEES simulator was designed in computer-aided design (CAD) software using anatomic measurements taken from anthropometric studies. Cross sections from external auditory canal samples were traced as vectors and serially combined into a mesh construct. A modified tympanic cavity with a modular testing platform for simulator tasks was incorporated. Components were fabricated using calcium sulfate hemihydrate powder and multiple colored infiltrants via a commercial inkjet 3D-printing service. All components of a left-sided ear were printed to scale. Six right-handed trainees completed three trials each. Mean trial time (n = 3) ranged from 23.03 to 62.77 s using the dominant hand for all dissection. Statistically significant differences between first and last completion time with the dominant hand (p < 0.05) and average completion time for junior and senior residents (p < 0.05) suggest construct validity. A 3D-printed simulator is feasible for TEES simulation. Otolaryngology training programs with access to a 3D printer may readily fabricate a TEES simulator, resulting in inexpensive yet high-fidelity surgical simulation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. A smartphone-driven methodology for estimating physical activities and energy expenditure in free living conditions.

    PubMed

    Guidoux, Romain; Duclos, Martine; Fleury, Gérard; Lacomme, Philippe; Lamaudière, Nicolas; Manenq, Pierre-Henri; Paris, Ludivine; Ren, Libo; Rousset, Sylvie

    2014-12-01

    This paper introduces a function dedicated to the estimation of total energy expenditure (TEE) of daily activities based on data from accelerometers integrated into smartphones. The use of mass-market sensors such as accelerometers offers a promising solution for the general public due to the growing smartphone market over the last decade. The TEE estimation function quality was evaluated using data from intensive numerical experiments based, first, on 12 volunteers equipped with a smartphone and two research sensors (Armband and Actiheart) in controlled conditions (CC) and, then, on 30 other volunteers in free-living conditions (FLC). The TEE given by these two sensors in both conditions and estimated from the metabolic equivalent tasks (MET) in CC served as references during the creation and evaluation of the function. The TEE mean gap in absolute value between the function and the three references was 7.0%, 16.4% and 2.7% in CC, and 17.0% and 23.7% according to Armband and Actiheart, respectively, in FLC. This is the first step in the definition of a new feedback mechanism that promotes self-management and daily-efficiency evaluation of physical activity as part of an information system dedicated to the prevention of chronic diseases. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. [Feasibility and results of transcatheter treatment of patent foramen ovale associated with atrial septal aneurysm. Experience of a general hospital in Mulhouse, France].

    PubMed

    Roth, O; Jacquemin, L; Kenizou, D; Mettauer, B; Monassier, J-P

    2007-11-01

    To evaluate the results and the feasibility of the technique of percutaneous closing of patent foramen oval (PFO) with Atrial Septal Aneurysm (ASA) among young patients having presented a cryptogenic cerebral ischemia. Eighteen patients: 14 cryptogenic stroke and 4 TIA with a broad PFO (rank III) and an important ASA (excursion higher than 15 mm) at transesophageal echocardiography (TEE). The average age is 48.2 years: man 61%, women 39%. The patients have little cardiovascular risk factor (0.83/patient) and 38% presented recurrent thromboembolic events. Percutaneous closing is carried out under general anaesthesia with TEE and Amplatzer devices implantation. A control TEE is carried out 6 months after closing. No complication occurred at the time of the procedures. After 72 hours, one patient presented a major complication: one arteriovenous fistula requiring a surgery. Five patients presented a minor complication: two non complicated femoral hematoma, two atrial arrhytmias and one asymptomatic secondary displacement of the device without need for surgery. Seven-teen patients had TEE at six months: the shunt disappeared for 95% from the patients, no thrombus was found. No recurrent thromboembolic event appeared for the 18 patients (median follow-up 19.2 months). The installation of a technique of percutaneous closing of the PFO+ASA is safe and effective.

  9. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    PubMed

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  10. Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports

    PubMed Central

    Baumgart, Christian; Polglaze, Ted; Freiwald, Jürgen

    2018-01-01

    This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6–8.0%; CV: 1.1–5.1%) and sprint mechanical properties (TEE: 4.5–14.3%; CV: 3.1–7.5%) than the 10 Hz GPS (TEE: 3.0–12.9%; CV: 2.5–13.0% and TEE: 4.1–23.1%; CV: 3.3–20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0–6.0%; CV: 0.7–5.0% and TEE: 2.1–9.2%; CV: 1.6–7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15

  11. Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports.

    PubMed

    Hoppe, Matthias W; Baumgart, Christian; Polglaze, Ted; Freiwald, Jürgen

    2018-01-01

    This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that

  12. Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study.

    PubMed

    Brage, Søren; Westgate, Kate; Franks, Paul W; Stegle, Oliver; Wright, Antony; Ekelund, Ulf; Wareham, Nicholas J

    2015-01-01

    Accurate assessment of energy expenditure (EE) is important for the study of energy balance and metabolic disorders. Combined heart rate (HR) and acceleration (ACC) sensing may increase precision of physical activity EE (PAEE) which is the most variable component of total EE (TEE). To evaluate estimates of EE using ACC and HR data with or without individual calibration against doubly-labelled water (DLW) estimates of EE. 23 women and 23 men (22-55 yrs, 48-104 kg, 8-46%body fat) underwent 45-min resting EE (REE) measurement and completed a 20-min treadmill test, an 8-min step test, and a 3-min walk test for individual calibration. ACC and HR were monitored and TEE measured over 14 days using DLW. Diet-induced thermogenesis (DIT) was calculated from food-frequency questionnaire. PAEE (TEE ÷ REE ÷ DIT) and TEE were compared to estimates from ACC and HR using bias, root mean square error (RMSE), and correlation statistics. Mean(SD) measured PAEE and TEE were 66(25) kJ·day(-1)·kg(-1), and 12(2.6) MJ·day(-1), respectively. Estimated PAEE from ACC was 54(15) kJ·day(-1)·kg(-1) (p<0.001), with RMSE 24 kJ·day(-1)·kg(-1) and correlation r = 0.52. PAEE estimated from HR and ACC+HR with treadmill calibration were 67(42) and 69(25) kJ·day(-1)·kg(-1) (bias non-significant), with RMSE 34 and 20 kJ·day(-1)·kg(-1) and correlations r = 0.58 and r = 0.67, respectively. Similar results were obtained with step-calibrated and walk-calibrated models, whereas non-calibrated models were less precise (RMSE: 37 and 24 kJ·day(-1)·kg(-1), r = 0.40 and r = 0.55). TEE models also had high validity, with biases <5%, and correlations r = 0.71 (ACC), r = 0.66-0.76 (HR), and r = 0.76-0.83 (ACC+HR). Both accelerometry and heart rate may be used to estimate EE in adult European men and women, with improved precision if combined and if heart rate is individually calibrated.

  13. Estimation of Free-Living Energy Expenditure by Heart Rate and Movement Sensing: A Doubly-Labelled Water Study

    PubMed Central

    Brage, Søren; Westgate, Kate; Franks, Paul W.; Stegle, Oliver; Wright, Antony; Ekelund, Ulf; Wareham, Nicholas J.

    2015-01-01

    Background Accurate assessment of energy expenditure (EE) is important for the study of energy balance and metabolic disorders. Combined heart rate (HR) and acceleration (ACC) sensing may increase precision of physical activity EE (PAEE) which is the most variable component of total EE (TEE). Objective To evaluate estimates of EE using ACC and HR data with or without individual calibration against doubly-labelled water (DLW) estimates of EE. Design 23 women and 23 men (22–55 yrs, 48–104 kg, 8–46%body fat) underwent 45-min resting EE (REE) measurement and completed a 20-min treadmill test, an 8-min step test, and a 3-min walk test for individual calibration. ACC and HR were monitored and TEE measured over 14 days using DLW. Diet-induced thermogenesis (DIT) was calculated from food-frequency questionnaire. PAEE (TEE ÷ REE ÷ DIT) and TEE were compared to estimates from ACC and HR using bias, root mean square error (RMSE), and correlation statistics. Results Mean(SD) measured PAEE and TEE were 66(25) kJ·day-1·kg-1, and 12(2.6) MJ·day-1, respectively. Estimated PAEE from ACC was 54(15) kJ·day-1·kg-1 (p<0.001), with RMSE 24 kJ·day-1·kg-1 and correlation r = 0.52. PAEE estimated from HR and ACC+HR with treadmill calibration were 67(42) and 69(25) kJ·day-1·kg-1 (bias non-significant), with RMSE 34 and 20 kJ·day-1·kg-1 and correlations r = 0.58 and r = 0.67, respectively. Similar results were obtained with step-calibrated and walk-calibrated models, whereas non-calibrated models were less precise (RMSE: 37 and 24 kJ·day-1·kg-1, r = 0.40 and r = 0.55). TEE models also had high validity, with biases <5%, and correlations r = 0.71 (ACC), r = 0.66–0.76 (HR), and r = 0.76–0.83 (ACC+HR). Conclusions Both accelerometry and heart rate may be used to estimate EE in adult European men and women, with improved precision if combined and if heart rate is individually calibrated. PMID:26349056

  14. Integrated Circuit Immunity

    NASA Technical Reports Server (NTRS)

    Sketoe, J. G.; Clark, Anthony

    2000-01-01

    This paper presents a DOD E3 program overview on integrated circuit immunity. The topics include: 1) EMI Immunity Testing; 2) Threshold Definition; 3) Bias Tee Function; 4) Bias Tee Calibration Set-Up; 5) EDM Test Figure; 6) EMI Immunity Levels; 7) NAND vs. and Gate Immunity; 8) TTL vs. LS Immunity Levels; 9) TP vs. OC Immunity Levels; 10) 7805 Volt Reg Immunity; and 11) Seventies Chip Set. This paper is presented in viewgraph form.

  15. Fireproof Hydraulic Brake System.

    DTIC Science & Technology

    1985-10-01

    MLBT elastomer personnel recommended the use of Firestone’s Phosphonitrilic Fluoroelastomer (PNF) for elastomeric O-rings in the CTFE fluid system. C.E...resealed with modified "PNF" (phosphonitrilic fluoroelastomer) elastomer Ŕ" rings. The hoses are PTFE lined for compatibility with the CTFE...Plus 65-42808-6 Nylon Braid )* AN837-8 Elbow (on Truck) 61-11536-1 Tube Assy (Strut/Truck Hose to Truck Tee)* 290 -7. 61-11530-1 Tube Assy (Truck Tee

  16. Fiber optic illumination of a poly(dimethylsiloxane) sheath flow cuvette for diode laser induced fluorescence detection in capillary electrophoresis.

    PubMed

    Skinner, Cameron D

    2015-02-01

    A Tee configuration sheath flow cuvette with square cross-section channels has been produced in PDMS for CE detection. The output of a 1.4 W laser diode operating at 450 nm was focused onto the 300 μm core of a 370 μm od fiber optic whose end was inserted into one arm of the Tee for LIF. The optimal configuration had the fiber optic positioned 500 μm downstream from the intersection and the end of the 35 cm 50 μm id 365 μm od capillary just outside the intersection and in the leg of the Tee, resulting in a 90° configuration. Detection limits of 50 and 3 pM and linear calibrations of at least three orders of magnitude were obtained for Lucifer Yellow and fluorescein, respectively. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Comparison of resting and total energy expenditure in peritoneal dialysis patients and body composition measured by dual-energy X-ray absorptiometry.

    PubMed

    El-Kateb, S; Sridharan, S; Farrington, K; Davenport, A

    2016-11-01

    Under basal resting conditions muscle metabolism is reduced, whereas metabolism increases with physical activity. We wished to determine whether there was an association between resting energy expenditure (REE) and total energy expenditure (TEE) in peritoneal dialysis (PD) patients and lean body mass (LBM). We determined REE and TEE by recently validated equations, using doubly labelled isotopic water, and LBM by dual-energy X-ray absorptiometry (DXA) scanning. We studied 87 patients, 50 male (57.4%), 25 diabetic (28.7%), mean age 60.3±17.6 years, with a median PD treatment of 11.4 (4.7-29.5) months. The mean weight was 70.1±17.7 kg with a REE of 1509±245 kcal/day and TEE 1947±378 kcal/day. REE was associated with body size (weight r=0.78 and body mass index (BMI) r=0.72) and body composition (LBM r=0.77, lean body mass index (LBMI) r=0.76, r=0.62), all P<0.001). For TEE, there was an association with weight r=0.58, BMI r=0.49 and body composition (LBM r=0.64, LBMI (r=0.54), all P<0.001). We compared LBMI measured by DXA and that estimated by the Boer equation using anthropomorphic measurements, which overestimated and underestimated LBM for smaller patients and heavier patients, respectively. Muscle metabolism is reduced at rest and increases with physical activity. Whereas previous reports based on REE did not show any association with LBM, we found an association between both REE and TEE, using a recently validated equation derived from dialysis patients, and LBM measured by DXA scanning. Estimation of muscle mass from anthropomorphic measurements systematically overestimated LBM for small patients and conversely underestimated for heavier patients.

  18. First in vivo evaluation of a flexible self-apposing left atrial appendage closure device in the canine model.

    PubMed

    Cheng, Yanping; Conditt, Gerard; Yi, Genghua; Tellez, Armando; Corcoran, Michael; Rousselle, Serge; Kaluza, Greg L; Granada, Juan F

    2015-07-01

    Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events. © 2015 Wiley Periodicals, Inc.

  19. Feasibility and Diagnostic Value of Cardiovascular Magnetic Resonance Imaging After Acute Ischemic Stroke of Undetermined Origin.

    PubMed

    Haeusler, Karl Georg; Wollboldt, Christian; Bentheim, Laura Zu; Herm, Juliane; Jäger, Sebastian; Kunze, Claudia; Eberle, Holger-Carsten; Deluigi, Claudia Christina; Bruder, Oliver; Malsch, Carolin; Heuschmann, Peter U; Endres, Matthias; Audebert, Heinrich J; Morguet, Andreas J; Jensen, Christoph; Fiebach, Jochen B

    2017-05-01

    Etiology of acute ischemic stroke remains undetermined (cryptogenic) in about 25% of patients after state-of-the-art diagnostic work-up. One-hundred and three patients with magnetic resonance imaging (MRI)-proven acute ischemic stroke of undetermined origin were prospectively enrolled and underwent 3-T cardiac MRI and magnetic resonance angiography of the aortic arch in addition to state-of-the-art diagnostic work-up, including transesophageal echocardiography (TEE). We analyzed the feasibility, diagnostic accuracy, and added value of cardiovascular MRI (cvMRI) compared with TEE for detecting sources of stroke. Overall, 102 (99.0%) ischemic stroke patients (median 63 years [interquartile range, 53-72], 24% female, median NIHSS (National Institutes of Health Stroke Scale) score on admission 2 [interquartile range, 1-4]) underwent cvMRI and TEE in hospital; 89 (86.4%) patients completed the cvMRI examination. In 93 cryptogenic stroke patients, a high-risk embolic source was found in 9 (8.7%) patients by cvMRI and in 11 (11.8%) patients by echocardiography, respectively. cvMRI and echocardiography findings were consistent in 80 (86.0%) patients, resulting in a degree of agreement of κ=0.24. In 82 patients with cryptogenic stroke according to routine work-up, including TEE, cvMRI identified stroke etiology in additional 5 (6.1%) patients. Late gadolinium enhancement consistent with previous myocardial infarction was found in 13 (14.6%) out of 89 stroke patients completing cvMRI. Only 2 of these 13 patients had known coronary artery disease. Our study demonstrated that cvMRI was feasible in the vast majority of included patients with acute ischemic stroke. The diagnostic information of cvMRI seems to be complementary to TEE but is not replacing echocardiography after acute ischemic stroke. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01917955. © 2017 American Heart Association, Inc.

  20. Total energy expenditure in the Yakut (Sakha) of Siberia as measured by the doubly labeled water method.

    PubMed

    Snodgrass, J Josh; Leonard, William R; Tarskaia, Larissa A; Schoeller, Dale A

    2006-10-01

    Populations in transition to a Western lifestyle display increased incidences of obesity, type 2 diabetes, and other chronic diseases; the mechanisms responsible for these changes, however, remain incompletely understood. Although reduced physical activity has been implicated, few studies have accurately quantified energy expenditure in subsistence populations. The aim of the study was to examine the relation of total energy expenditure (TEE) and activity [physical activity level (PAL), activity energy expenditure (AEE), and weight-adjusted AEE (AEE/kg)] with body composition and lifestyle in the Yakut (Sakha), an indigenous high-latitude Siberian group. We measured TEE using doubly labeled water and resting metabolic rate using indirect calorimetry in 28 young adults (14 women and 14 men) from Berdygestiakh, Russia. The men had higher TEE (12,983 compared with 9620 kJ/d; P < 0.01), AEE (5248 compared with 3203 kJ/d; P < 0.05), AEE/kg (72.7 compared with 48.8 kJ . kg(-1) . d(-1); P < 0.05), and PAL (1.7 compared with 1.5; P = 0.09) than did the women, although this may reflect, in part, body size and composition differences. Overweight men and women had modestly higher TEEs than did lean participants; when adjusted for body size, activity levels were not significantly different between the groups. Persons with more traditional lifestyles had higher TEEs and PALs than did persons with more modernized lifestyles; this difference correlated with differences in participation in subsistence activities. Activity levels in the Yakut were lower than those in other subsistence groups, especially the women, and were not significantly different from those in persons in industrialized nations. Persons who participated in more subsistence activities and consumed fewer market foods had significantly higher activity levels.

  1. From accuracy to patient outcome and cost-effectiveness evaluations of diagnostic tests and biomarkers: an exemplary modelling study

    PubMed Central

    2013-01-01

    Background Proper evaluation of new diagnostic tests is required to reduce overutilization and to limit potential negative health effects and costs related to testing. A decision analytic modelling approach may be worthwhile when a diagnostic randomized controlled trial is not feasible. We demonstrate this by assessing the cost-effectiveness of modified transesophageal echocardiography (TEE) compared with manual palpation for the detection of atherosclerosis in the ascending aorta. Methods Based on a previous diagnostic accuracy study, actual Dutch reimbursement data, and evidence from literature we developed a Markov decision analytic model. Cost-effectiveness of modified TEE was assessed for a life time horizon and a health care perspective. Prevalence rates of atherosclerosis were age-dependent and low as well as high rates were applied. Probabilistic sensitivity analysis was applied. Results The model synthesized all available evidence on the risk of stroke in cardiac surgery patients. The modified TEE strategy consistently resulted in more adapted surgical procedures and, hence, a lower risk of stroke and a slightly higher number of life-years. With 10% prevalence of atherosclerosis the incremental cost-effectiveness ratio was €4,651 and €481 per quality-adjusted life year in 55-year-old men and women, respectively. In all patients aged 65 years or older the modified TEE strategy was cost saving and resulted in additional health benefits. Conclusions Decision analytic modelling to assess the cost-effectiveness of a new diagnostic test based on characteristics, costs and effects of the test itself and of the subsequent treatment options is both feasible and valuable. Our case study on modified TEE suggests that it may reduce the risk of stroke in cardiac surgery patients older than 55 years at acceptable cost-effectiveness levels. PMID:23368927

  2. A three-dimensional insight into the complexity of flow convergence in mitral regurgitation: adjunctive benefit of anatomic regurgitant orifice area.

    PubMed

    Chandra, Sonal; Salgo, Ivan S; Sugeng, Lissa; Weinert, Lynn; Settlemier, Scott H; Mor-Avi, Victor; Lang, Roberto M

    2011-09-01

    Mitral effective regurgitant orifice area (EROA) using the flow convergence (FC) method is used to quantify the severity of mitral regurgitation (MR). However, it is challenging and prone to interobserver variability in complex valvular pathology. We hypothesized that real-time three-dimensional (3D) transesophageal echocardiography (RT3D TEE) derived anatomic regurgitant orifice area (AROA) can be a reasonable adjunct, irrespective of valvular geometry. Our goals were to 1) to determine the regurgitant orifice morphology and distance suitable for FC measurement using 3D computational flow dynamics and finite element analysis (FEA), and (2) to measure AROA from RT3D TEE and compare it with 2D FC derived EROA measurements. We studied 61 patients. EROA was calculated from 2D TEE images using the 2D-FC technique, and AROA was obtained from zoomed RT3DE TEE acquisitions using prototype software. 3D computational fluid dynamics by FEA were applied to 3D TEE images to determine the effects of mitral valve (MV) orifice geometry on FC pattern. 3D FEA analysis revealed that a central regurgitant orifice is suitable for FC measurements at an optimal distance from the orifice but complex MV orifice resulting in eccentric jets yielded nonaxisymmetric isovelocity contours close to the orifice where the assumptions underlying FC are problematic. EROA and AROA measurements correlated well (r = 0.81) with a nonsignificant bias. However, in patients with eccentric MR, the bias was larger than in central MR. Intermeasurement variability was higher for the 2D FC technique than for RT3DE-based measurements. With its superior reproducibility, 3D analysis of the AROA is a useful alternative to quantify MR when 2D FC measurements are challenging.

  3. Pathophysiologic correlates of thromboembolism in nonvalvular atrial fibrillation: I. Reduced flow velocity in the left atrial appendage (The Stroke Prevention in Atrial Fibrillation [SPAF-III] study).

    PubMed

    Goldman, M E; Pearce, L A; Hart, R G; Zabalgoitia, M; Asinger, R W; Safford, R; Halperin, J L

    1999-12-01

    Stroke associated with atrial fibrillation (AF) is mainly due to embolism of thrombus formed during stasis of blood in the left atrial appendage (LAA). Pathophysiologic correlates of appendage flow velocity as assessed by transesophageal echocardiography (TEE) in patients with AF have not been defined. To evaluate the hypothesis that reduced velocity is associated with spontaneous echocardiographic contrast and thrombus in the LAA and with clinical embolic events, we measured LAA flow velocity by TEE in 721 patients with nonvalvular AF entering the Stroke Prevention in Atrial Fibrillation (SPAF-III) study. Patient features, TEE findings, and subsequent cardioembolic events were correlated with velocity by multivariate analysis. Patients in AF during TEE displayed lower peak antegrade (emptying) flow velocity (Anu(p)) than those with intermittent AF in sinus rhythm during TEE (33 cm/s vs 61 cm/s, respectively, P <.0001). Anu(p) < 20 cm/s was associated with dense spontaneous echocardiographic contrast (P <.001), appendage thrombus (P <.01), and subsequent cardioembolic events (P <.01). Independent predictors of Anu(p) < 20 cm/s included age (P =.009), systolic blood pressure (P <.001), sustained AF (P =.01), ischemic heart disease (P =.01), and left atrial area (P =.04). Multivariate analysis found both Anu(p) <20 cm/s (relative risk 2.6, P =.02) and clinical risk factors (relative risk 3.3, P =.002) independently associated with LAA thrombus. LAA Anu(p) is reduced in AF and associated with spontaneous echocardiographic contrast, appendage thrombus, and cardioembolic stroke. Systolic hypertension and aortic atherosclerosis, independent clinical predictors of stroke in patients with AF, also correlated with LAA Anu(p). Our results support the role of reduced LAA Anu(p) in the generation of stasis, thrombus formation, and embolism in patients with AF, although other mechanisms also contribute to stroke.

  4. Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature.

    PubMed

    Tanis, Wilco; Habets, Jesse; van den Brink, Renee B A; Symersky, Petr; Budde, Ricardo P J; Chamuleau, Steven A J

    2014-02-01

    For acquired mechanical prosthetic heart valve (PHV) obstruction and suspicion on thrombosis, recently updated European Society of Cardiology guidelines advocate the confirmation of thrombus by transthoracic echocardiography, transesophageal echocardiography (TEE), and fluoroscopy. However, no evidence-based diagnostic algorithm is available for correct thrombus detection, although this is clinically important as fibrinolysis is contraindicated in non-thrombotic obstruction (isolated pannus). Here, we performed a review of the literature in order to propose a diagnostic algorithm. We performed a systematic search in Pubmed and Embase. Included publications were assessed on methodological quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS) II checklist. Studies were scarce (n = 15) and the majority were of moderate methodological quality. In total, 238 mechanical PHV's with acquired obstruction and a reliable reference standard were included for the evaluation of the role of fluoroscopy, echocardiography, or multidetector-row computed tomography (MDCT). In acquired PHV obstruction caused by thrombosis, mass detection by TEE and leaflet restriction detected by fluoroscopy were observed in the majority of cases (96 and 100%, respectively). In contrast, in acquired PHV obstruction free of thrombosis (pannus), leaflet restriction detected by fluoroscopy was absent in some cases (17%) and mass detection by TEE was absent in the majority of cases (66%). In case of mass detection by TEE, predictors for obstructive thrombus masses (compared with pannus masses) were leaflet restriction, soft echo density, and increased mass length. In situations of inconclusive echocardiography, MDCT may correctly detect pannus/thrombus based on the morphological aspects and localization. In acquired mechanical PHV obstruction without leaflet restriction and absent mass on TEE, obstructive PHV thrombosis cannot be confirmed and consequently, fibrinolysis

  5. The Incidence of Patent Foramen Ovale in 1,000 Consecutive Patients: A Contrast Transesophageal Echocardiography Study

    NASA Technical Reports Server (NTRS)

    Fisher, Daniel C.; Fisher, Edward A.; Budd, Jacqueline H.; Rosen, Stacey E.; Goldman, Martin E.

    1995-01-01

    Study objective: Patent foramen ovale (PFO) is present in 10 to 35% of people and has been reported to be an important risk factor for cardioembolic cerebrovascular accidents (CVAs) and transient ischemic attacks (TIAS), especially in younger patients. While contrast transthoracic echocardiography has been used to detect PFO, contrast transesophageal echocardiography (TEE) has a greater sensitivity. Prior studies reported the incidence of PFO in patients presenting with a CVA or TIA. Design: To determine the incidence of PFO in a more general population, we reviewed 1,000 consecutive TEES performed with contrast and color Doppler for the presence of PFO and other cardioembolic risk factors, including atrial septal aneurysm (ASA), aortic plaque, atrial fibrillation (AFib), and atrial thrombi. While imaging with monoplane or biplane TEE, multiple injections of agitated saline solution were injected during cough or Valsalva maneuver to detect flow through a PFO. Patients: There were 482 male and 518 female patients with mean age of 60 + 17 years (range 11 to 93 years). Results: Patent foramen ovale was found in 9.2% of all patients and, though seen in all age groups divided by decade, the incidence in patients aged 40 to 49 years was greater than those aged 70 to 79 years (12.96% vs 6.15%',, p=0.03). Contrast TEE had a much higher detection rate than color Doppler alone. Importantly, there was no greater incidence of PFO in patients with CVA vs thos without CVA, or in male vs female patients. Also, there was a very strong correlation between the presence of ASA and PFO (p<.001). Conclusion: Thus, PFO detected by TEE, frequently seen with ASA, is seen in all age groups and does not in itself present a risk factor for CVA. The association of PFO with peripheral thrombosis and CVA needs further study.

  6. Comparison of a web-based food record tool and a food-frequency questionnaire and objective validation using the doubly labelled water technique in a Swedish middle-aged population.

    PubMed

    Nybacka, Sanna; Bertéus Forslund, Heléne; Wirfält, Elisabet; Larsson, Ingrid; Ericson, Ulrika; Warensjö Lemming, Eva; Bergström, Göran; Hedblad, Bo; Winkvist, Anna; Lindroos, Anna Karin

    2016-01-01

    Two web-based dietary assessment tools have been developed for use in large-scale studies: the Riksmaten method (4-d food record) and MiniMeal-Q (food-frequency method). The aim of the present study was to examine the ability of these methods to capture energy intake against objectively measured total energy expenditure (TEE) with the doubly labelled water technique (TEE DLW ), and to compare reported energy and macronutrient intake. This study was conducted within the pilot study of the Swedish CArdioPulmonary bioImage Study (SCAPIS), which included 1111 randomly selected men and women aged 50-64 years from the Gothenburg general population. Of these, 200 were enrolled in the SCAPIS diet substudy. TEE DLW was measured in a subsample ( n 40). Compared with TEE DLW , both methods underestimated energy intake: -2·5 (sd  2·9) MJ with the Riksmaten method; -2·3 (sd 3·6) MJ with MiniMeal-Q. Mean reporting accuracy was 80 and 82 %, respectively. The correlation between reported energy intake and TEE DLW was r 0·4 for the Riksmaten method ( P  < 0·05) and r 0·28 (non-significant) for MiniMeal-Q. Women reported similar average intake of energy and macronutrients in both methods whereas men reported higher intakes with the Riksmaten method. Energy-adjusted correlations ranged from 0·14 (polyunsaturated fat) to 0·77 (alcohol). Bland-Altman plots showed acceptable agreement for energy and energy-adjusted protein and carbohydrate intake, whereas the agreement for fat intake was poorer. According to energy intake data, both methods displayed similar precision on energy intake reporting. However, MiniMeal-Q was less successful in ranking individuals than the Riksmaten method. The development of methods to achieve limited under-reporting is a major challenge for future research.

  7. Comparison of resting energy equations and total energy expenditure in haemodialysis patients and body composition measured by multi-frequency bioimpedance.

    PubMed

    Oliveira, Ben; Sridharan, Sivakumar; Farrington, Ken; Davenport, Andrew

    2017-07-13

    Waste products of metabolism are retained in haemodialysis (HD) patients. Cellular metabolism generates energy, and patients with greater energy expenditure may therefore require more dialysis. To determine the amount of dialysis required, equations estimating resting and total energy expenditure (REE,TEE) are required. We compared estimates of REE in HD patients using established equations with a novel equation recently validated in HD patients (HD equation). TEE was derived from REE (HD equation) and estimates of physical activity obtained by questionnaire. REE and TEE relationships with bioimpedance measured body composition were then determined. We studied 317 HD patients; 195 males (61.5%), 123 diabetic (38.9%), mean age 65.0 ± 15.3 and weight 73.1 ± 16.8 kg. REE from HD Equation was 1509 ± 241 kcal/day, which was greater than for Mifflin St Joer 1384 ± 259, Harris-Benedict 1437 ± 244, Katch-McArdle 1345 ± 232 (all p < 0.05 vs HD Equation), but less than Cunningham 1557 ± 236 kcal/day. Bland Altman mean bias ranged from -263 to 55 kcal/day. TEE was 1727 (1558-1976) kcal/day, and on multi-variable analysis was positively associated with skeletal muscle mass (β 23.3, p < 0.001), employment (β 406.5, p < 0.001), low co-morbidity (β 105.1, p = 0.006), and protein nitrogen appearance (β 2.7, p = 0.015), and negatively with age (β -7.9, p < 0.001), and dialysis vintage (β -121.2, p = 0.002). Most standard equations underestimate REE in HD patients compared to the HD Equation. TEE was greater in those with higher skeletal muscle mass and protein nitrogen appearance, lower co-morbidity, age, and dialysis vintage, and the employed. More metabolically active patients may require greater dialytic clearances. This article is protected by copyright. All rights reserved.

  8. Evaluating the morphology of the left atrial appendage by a transesophageal echocardiographic 3-dimensional printed model

    PubMed Central

    Song, Hongning; Zhou, Qing; Zhang, Lan; Deng, Qing; Wang, Yijia; Hu, Bo; Tan, Tuantuan; Chen, Jinling; Pan, Yiteng; He, Fazhi

    2017-01-01

    Abstract The novel 3-dimensional printing (3DP) technique has shown its ability to assist personalized cardiac intervention therapy. This study aimed to determine the feasibility of 3D-printed left atrial appendage (LAA) models based on 3D transesophageal echocardiography (3D TEE) data and their application value in treating LAA occlusions. Eighteen patients with transcatheter LAA occlusion, and preprocedure 3D TEE and cardiac computed tomography were enrolled. 3D TEE volumetric data of the LAA were acquired and postprocessed for 3DP. Two types of 3D models of the LAA (ie, hard chamber model and flexible wall model) were printed by a 3D printer. The morphological classification and lobe identification of the LAA were assessed by the 3D chamber model, and LAA dimensions were measured via the 3D wall model. Additionally, a simulation operative rehearsal was performed on the 3D models in cases of challenging LAA morphology for the purpose of understanding the interactions between the device and the model. Three-dimensional TEE volumetric data of the LAA were successfully reprocessed and printed as 3D LAA chamber models and 3D LAA wall models in all patients. The consistency of the morphological classifications of the LAA based on 3D models and cardiac computed tomography was 0.92 (P < .01). The differences between the LAA ostium dimensions and depth measured using the 3D models were not significant from those measured on 3D TEE (P > .05). A simulation occlusion was successfully performed on the 3D model of the 2 challenging cases and compared with the real procedure. The echocardiographic 3DP technique is feasible and accurate in reflecting the spatial morphology of the LAA, which may be promising for the personalized planning of transcatheter LAA occlusion. PMID:28930824

  9. Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis.

    PubMed

    Smíd, Michal; Ferda, Jirí; Baxa, Jan; Cech, Jakub; Hájek, Tomás; Kreuzberg, Boris; Rokyta, Richard

    2010-04-01

    Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.

    PubMed

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    2016-02-01

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.

  11. Oxyresveratrol, a Stilbene Compound from Morus alba L. Twig Extract Active Against Trichophyton rubrum.

    PubMed

    Lu, Hai-Peng; Jia, Ya-Nan; Peng, Ya-Lin; Yu, Yan; Sun, Si-Long; Yue, Meng-Ting; Pan, Min-Hui; Zeng, Ling-Shu; Xu, Li

    2017-12-01

    Morus alba L. (mulberry) twig is known to have an inhibitory effect on pathogens in traditional Chinese medicine. In the present study, the dermophytic fungus, Trichophyton rubrum, was used to evaluate the inhibitory effect of total M. alba twig extract and extracts obtained using solvents with different polarities by the method of 96-well MTT colorimetry. The main active substance was isolated and identified by tracking its activity. In addition, the inhibitory effects of active extracts and a single active substance were investigated in combination with miconazole nitrate. Our data indicated that ethyl acetate extracts of mulberry twig (TEE) exhibited a desired inhibitory activity on T. rubrum with the minimum inhibitory concentration (MIC) of 1.000 mg/mL. With activity tracking, the main substance showing antimicrobial activity was oxyresveratrol (OXY), which was isolated from TEE. Its MIC for inhibiting the growth of T. rubrum was 0.500 mg/mL. The combined use of miconazole nitrate and OXY showed a synergistic inhibitory effect, as shown by a significant decrease in the MIC of both components. Based on the OXY content in TEE, the contribution rate of OXY to the inhibitory effect of TEE on T. rubrum was 80.52%, so it was determined to be the main antimicrobial substance in M. alba twig. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.

    PubMed

    Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther

    2017-07-01

    Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.

  13. Transesophageal echocardiography in the management of burn patients.

    PubMed

    Maybauer, Marc O; Asmussen, Sven; Platts, David G; Fraser, John F; Sanfilippo, Filippo; Maybauer, Dirk M

    2014-06-01

    A systematic review was conducted to assess the level of evidence for the use of transesophageal echocardiography (TEE) in the management of burn patients. We searched any article published before and including June 30, 2013. Our search yielded 118 total publications, 11 met the inclusion criteria of burn injury and TEE. Available studies published in any language were rated and included. At the present time, there are no available systematic reviews/meta-analyses published that met our search criteria. Only a small number of clinical trials, all with a limited number of patients were available. Therefore, a meta-analysis on outcome parameters was not performed. However, the major pathologic findings in burn patients were reduced left ventricular (LV) systolic and diastolic function, mitral valve vegetation, pulmonary hypertension, pericardial effusion, fluid overload, and right heart failure. The advantages of TEE include offering direct assessment of cardiac valve competency, myocardial contractility, and most importantly real time assessment of adequacy of hemodynamic resuscitation and preload in the acute phase of resuscitation, with minimal additional risk. TEE serves multiple diagnostic purposes and is being used to better understand the fluid status and cardiac physiology of the critically ill burn patient. Randomized controlled trials especially on fluid resuscitation and cardiac performance in acute burns are warranted to potentially further improve outcome. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  14. Role of Negative Trans-Thoracic Echocardiography in the Diagnosis of Infective Endocarditis.

    PubMed

    Leitman, Marina; Peleg, Eli; Shmueli, Ruthie; Vered, Zvi

    2016-07-01

    The search for the presence of vegetations in patients with suspected infective endocarditis is a major indication for trans-esophageal echocardiographic (TEE) examinations. Advances in harmonic imaging and ongoing improvement in modern echocardiographic systems allow adequate quality of diagnostic images in most patients. To investigate whether TEE examinations are always necessary for the assessment of patients with suspected infective endocarditis. During 2012-2014 230 trans-thoracic echo (TTE) exams in patients with suspected infective endocarditis were performed at our center. Demographic, epidemiological, clinical and echocardiographic data were collected and analyzed, and the final clinical diagnosis and outcome were determined. Of 230 patients, 24 had definite infective endocarditis by clinical assessment. TEE examination was undertaken in 76 of the 230 patients based on the clinical decision of the attending physician. All TTE exams were classified as: (i) positive, i.e., vegetations present; (ii) clearly negative; or (iii) non-conclusive. Of the 92 with clearly negative TTE exams, 20 underwent TEE and all were negative. All clearly negative patients had native valves, adequate quality images, and in all 92 the final diagnosis was not infective endocarditis. Thus, the negative predictive value of a clearly negative TTE examination was 100%. In patients with native cardiac valves referred for evaluation for infective endocarditis, an adequate quality TTE with clearly negative examination may be sufficient for the diagnosis.

  15. Temporo-mandibular joint dislocation: an unusual complication of transoesophageal echocardiography.

    PubMed

    Anantharam, Brijesh; Chahal, Navtej; Stephens, Nigel; Senior, Roxy

    2010-03-01

    Temporo-mandibular joint (TMJ) dislocation is an unusual complication of transoesophageal echocardiography (TEE). We report a rare case of bilateral TMJ dislocation in an 84-year-old man prior to DC cardioversion (DCCV) for atrial flutter. Shortly after TEE and DCCV, the patient complained of bilateral facial pain. An orthopantomogram revealed bilateral TMJ dislocation. A closed reduction was performed by maxillo-facial surgeons under intravenous anaesthesia. Although very uncommon, the physician should be aware of the complication and its management.

  16. Vocal Cord Paralysis and Laryngeal Trauma in Cardiac Surgery.

    PubMed

    Chen, Yung-Yuan; Chia, Yeo-Yee; Wang, Pa-Chun; Lin, Hsiu-Yen; Tsai, Chiu-Ling; Hou, Shaw-Min

    2017-11-01

    Cardiac surgery - associated iatrogenic laryngeal trauma is often overlooked. We investigated the risk factors of vocal cord paralysis in cardiac surgery. Medical records were reviewed from 169 patients who underwent elective or emergency cardiac surgeries. Patients had transesophageal echocardiography (TEE) placed either under video fiberscopic image guidance (guided group) or blind placement (blind group). Routine postoperative otolaryngologist consultation with video laryngoscopic recording were performed. Vocal cord paralyses were found in 18 patients (10.7%; left-13, right-4, bilateral-1). The risk of vocal cord paralysis was associated with emergency operation [odds ratio, 97.5 (95% confidence interval [CI], 2.9 to 366), p = 0.01]. Use of fiberscope-guided TEE [odds ratio, 0.04 (95% CI 0.01 to 0.87), p = 0.04] can effectively reduce vocal cord injury. Emergency cardiac surgery increased the risk of vocal cord paralysis. Fiberscope-guided TEE placement is recommended for all patients having cardiac surgery to decrease the risk of severe peri-operative laryngeal trauma.

  17. Preventive health care, 1999 update: 2. Echocardiography for the detection of a cardiac source of embolus in patients with stroke

    PubMed Central

    Kapral, M K; Silver, F L

    1999-01-01

    OBJECTIVE: To develop guidelines for the use of echocardiography in the investigation of patients with stroke. OPTIONS: (1) Routine transthoracic echocardiography (TTE); (2) routine transesophageal echocardiography (TEE); (3) routine TTE followed by TEE if the TTE findings are noncontributory; (4) selective TTE or TEE in patients with cardiac disease who would not otherwise receive anticoagulant therapy. OUTCOMES: This article reviews the available evidence on the yield of TTE and TEE in detecting cardiac sources of cerebral emboli in patients with stroke, the effectiveness of treatment for cardiac sources of emboli and the effectiveness of screening echocardiography for secondary stroke prevention. EVIDENCE: MEDLINE was searched for relevant articles published from January 1966 to April 1998; also reviewed were additional articles identified from the bibliographies and citations obtained from experts. BENEFITS, HARMS AND COSTS: Echocardiography can detect intracardiac masses (thrombus, vegetation or tumour) in about 4% (with TTE) to 11% (with TEE) of stroke patients. The yield is lower among patients without clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (less than 2%) than among patients with clinical evidence of cardiac disease (less than 19%). The risks of echocardiography to patients are small. TTE has virtually no risks, and TEE is associated with cardiac, pulmonary and bleeding complications in 0.18%. Patients with an identified intracardiac thrombus are at increased risk for embolic events (absolute risk uncertain, range 0%-38%), and this appears to be reduced with anticoagulant therapy (absolute risk reduction uncertain). Anticoagulant therapy carries a risk of major hemorrhage of 1% to 3% per year. The overall effectiveness of echocardiography in the prevention of recurrent stroke is unknown. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on

  18. Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography.

    PubMed

    Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi

    2013-09-01

    A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

  19. Partial rupture of the tricuspid valve after extraction of permanent pacemaker leads: detection by transesophageal echocardiography.

    PubMed

    Assayag, P; Thuaire, C; Benamer, H; Sebbah, J; Leport, C; Brochet, E

    1999-06-01

    Traumatic lesions of the tricuspid valve complicating pacemaker lead extractions appear to be rare. We report two cases of partial rupture of the tricuspid valve, following apparently uneventful extraction of permanent ventricular leads, resulting in severe regurgitation and, in one case, chronic heart failure. TEE was useful to identify the traumatic mechanism of tricuspid regurgitation (TR) and the extent of valvular lesions in these patients. Such etiology should be suspected, and TEE performed, in patients developing TR or heart failure late after lead extraction.

  20. Device-less patent foramen ovale closure by radiofrequency thermal energy.

    PubMed

    Walpoth, Nazan B; Habermacher, Kathrin; Moarof, Igal; Watson, Sandy; Wahl, Andreas; Windecker, Stephan; Schönenberger, Christa; Meier, Bernhard

    2008-02-23

    The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. The results confirm that radiofrequency closure of the PFO is safe

  1. [Echographic diagnosis of systolic murmur among 280 young French militaries. Implications for the expertise in military medicine].

    PubMed

    Vinsonneau, U; Vermeulen, L; Griffet, V; Delluc, A; Paleiron, N; Le Ven, F; Rohel, G; Jobic, Y; Piquemal, M; Mansourati, J; Paule, P

    2015-04-01

    Clinically discovering a systolic murmur is frequent among the young military population. When this murmur does not sound benign, a transthoracic echocardiography (TTE) is made to detect any cardiopathy, which could cause sudden cardiac death. The aim of this study was to evaluate the interest of systematic TTE in the assessment of any cardiac systolic murmur (CSM) among militaries. We ran a retrospective monocentric study in the "Clermont-Tonnerre" military hospital in Brest. We included all patients sent for TEE, aged 15 to 30 years old, from the 1st January 2010 until the 31st July 2013. Two hundred and eighty TTES assessing CSM were performed. We found 28/280 (10%) echocardiographic abnormalities: 13 were bicuspid aortic valves (4.6%), 6 were ventricular septal defects (2.15%), 3 were atrial septal defects (1.07%), 4 were mild mitral regurgitations (1.43%), one mild pulmonary stenosis (0.35%) and one aortic stenosis (0.35%). No hypertrophic cardiomyopathy was found. Concerning military expertise, 11 (3.92%) patients among these 28 with abnormal TEE were considered unfit for work or "fit for work with limitations". Assessing a cardiac systolic murmur with TEE lead to the diagnosis of a cardiomyopathy in 10% of the case. This study enhances the importance of systematic TEE when a CSM is detected in the young military, in order to determine if those soldiers can still fulfill their military duty. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. Accuracy assessment of fluoroscopy-transesophageal echocardiography registration

    NASA Astrophysics Data System (ADS)

    Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.

    2011-03-01

    This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.

  3. Patent foramen ovale and atrial septal aneurysm can cause ischemic stroke in patients with antiphospholipid syndrome.

    PubMed

    Tanaka, Yasutaka; Ueno, Yuji; Miyamoto, Nobukazu; Shimada, Yoshiaki; Tanaka, Ryota; Hattori, Nobutaka; Urabe, Takao

    2013-01-01

    The purpose of the present study was to evaluate the contributions of embolic etiologies, patent foramen ovale (PFO) and atrial septal aneurysm (ASA) to the pathogenesis of ischemic stroke in patients with antiphospholipid syndrome (APS). We performed transesophageal echocardiography (TEE) examination for consecutive stroke patients who had been diagnosed with APS (APS group) to detect potential embolic sources. APS was diagnosed based on the modified Sapporo criteria. The control stroke group comprised age- and sex-matched cryptogenic stroke patients undergoing TEE. We assessed and compared the clinical characteristics and TEE findings between stroke patients with APS and control stroke groups. Among 582 patients, nine patients (nine women; mean age, 50 ± 18 years) were classified into the APS group. In 137 patients undergoing TEE, 41 age-matched female stroke patients were recruited to the control stroke group. Prevalences of PFO and ASA were significantly higher in the APS group than in the control stroke group (89 vs. 41 %, p = 0.027; 67 vs. 20 %, p = 0.015, respectively). Multiple logistic regression analysis showed that PFO (odds ratio (OR), 13.71; 95 % confidence interval (CI), 1.01-185.62; p = 0.049) and ASA (OR, 8.06; 95 % CI, 1.17-55.59; p = 0.034) were independently associated with the APS group. PFO and ASA were strongly associated with the APS group, and could thus represent potential embolic sources in ischemic stroke patients with APS.

  4. Transapical off-pump mitral valve repair. First experience with the NeoChord system in Poland (report of two cases).

    PubMed

    Wróbel, Krzysztof; Kurnicka, Katarzyna; Zygier, Marcin; Dyk, Wojciech; Wojdyga, Ryszard; Zieliński, Dariusz; Jarzębska, Małgorzata; Juraszyński, Zbigniew; Lichodziejewska, Barbara; Pruszczyk, Piotr; Biederman, Andrzej; Speziali, Giovanni; Kasten, Uwe

    2017-01-01

    Artificial chord implantation to repair a flail or prolapsing mitral valve leaflet requires open heart surgery and cardiopulmonary bypass. Transapical off-pump artificial chordae implantation is a new surgical technique proposed to treat degenerative mitral valve regurgitation. The procedure is performed using the NeoChord DS1000 system (NeoChord, Inc., St. Louis Park, MN, USA), which facilitates both implantation and lenght adjustment of the artificial chordae under two (2D)- and three (3D)-dimensional transoesophageal echocardiographic (TEE) guidance on a beating heart. Two male patients aged 60 and 55 years with severe mitral regurgitation due to posterior leaflet prolapse underwent transapical off-pump artificial chordae implantation on September 3, 2015. The procedure was performed by left minithoracotomy under general anaesthesia in a cardiac surgical theatre, using 2D and 3D TEE guidance. Early procedural success as confirmed by 3D TEE was achieved in both patients, with implantation of 6 artificial chordae in the first patient and 3 artificial chordae in the second patient. Both procedures were uneventful, and no postoperative complications were noted. The patients were discharged home on the 8th and 6th postoperative day, respectively. The NeoChord DS1000 system allows both implantation and lenght adjustment of artificial chordae under 2D and 3D TEE guidance on a beating heart. Our initial experience in 2 patients with posterior mitral leaflet prolapse indicates that the procedure is feasible and safe.

  5. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    PubMed

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  6. Vocal Cord Paralysis and Laryngeal Trauma in Cardiac Surgery

    PubMed Central

    Chen, Yung-Yuan; Chia, Yeo-Yee; Wang, Pa-Chun; Lin, Hsiu-Yen; Tsai, Chiu-Ling; Hou, Shaw-Min

    2017-01-01

    Background Cardiac surgery – associated iatrogenic laryngeal trauma is often overlooked. We investigated the risk factors of vocal cord paralysis in cardiac surgery. Methods Medical records were reviewed from 169 patients who underwent elective or emergency cardiac surgeries. Patients had transesophageal echocardiography (TEE) placed either under video fiberscopic image guidance (guided group) or blind placement (blind group). Routine postoperative otolaryngologist consultation with video laryngoscopic recording were performed. Results Vocal cord paralyses were found in 18 patients (10.7%; left-13, right-4, bilateral-1). The risk of vocal cord paralysis was associated with emergency operation [odds ratio, 97.5 (95% confidence interval [CI], 2.9 to 366), p = 0.01]. Use of fiberscope-guided TEE [odds ratio, 0.04 (95% CI 0.01 to 0.87), p = 0.04] can effectively reduce vocal cord injury. Conclusions Emergency cardiac surgery increased the risk of vocal cord paralysis. Fiberscope-guided TEE placement is recommended for all patients having cardiac surgery to decrease the risk of severe peri-operative laryngeal trauma. PMID:29167615

  7. Echocardiographic Assessment of Heart Valve Prostheses

    PubMed Central

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  8. Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 2, phase 2: Subsize heat shield and small size TPS evaluation

    NASA Technical Reports Server (NTRS)

    Black, W. E.

    1973-01-01

    Initially a trade study was conducted of seven heat shield configurations. These were evaluated for structural reliability, fabricability, weight, inspectability, and refurbishability. Two concepts, a tee-stiffened and an open corrugation, were selected as offering the most potential for system success. Fourteen subsize heat shields of a full scale section were fabricated from C-129Y and Cb-752 and silicide coated with R-512E. These subsize panels were subjected to a simulated flight profile representing temperature, local surface pressures, and applied pressure differential loads. All corrugated panels of both alloys sustained 100 cycles without structural or coating failure. All Cb-752/R-512E panels performed well with one panel being successfully repaired after 66 cycles and completing 100 cycles. As a result of this evaluating the Cb-752/R-512E system was selected for hardware application during the subsequent phases. In addition, the tee-stiffened configuration was selected for further development and application in Phase III. This selection was based on an overall assessment of relative weight, cost, and structural performance of the tee-stiffened and open corrugation TPS.

  9. Echocardiography in Infective Endocarditis: State of the Art.

    PubMed

    Afonso, Luis; Kottam, Anupama; Reddy, Vivek; Penumetcha, Anirudh

    2017-10-25

    In this review, we examine the central role of echocardiography in the diagnosis, prognosis, and management of infective endocarditis (IE). 2D transthoracic echocardiography (TTE) and transesophageal echocardiography TEE have complementary roles and are unequivocally the mainstay of diagnostic imaging in IE. The advent of 3D and multiplanar imaging have greatly enhanced the ability of the imager to evaluate cardiac structure and function. Technologic advances in 3D imaging allow for the reconstruction of realistic anatomic images that in turn have positively impacted IE-related surgical planning and intervention. CT and metabolic imaging appear to be emerging as promising ancillary diagnostic tools that could be deployed in select scenarios to circumvent some of the limitations of echocardiography. Our review summarizes the indispensable and central role of various echocardiographic modalities in the management of infective endocarditis. The complementary role of 2D TTE and TEE are discussed and areas where 3D TEE offers incremental value highlighted. An algorithm summarizing a contemporary approach to the workup of endocarditis is provided and major societal guidelines for timing of surgery are reviewed.

  10. Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.

    PubMed

    Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak

    2012-06-01

    Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the

  11. Evaluation of the ability of three physical activity monitors to predict weight change and estimate energy expenditure.

    PubMed

    Correa, John B; Apolzan, John W; Shepard, Desti N; Heil, Daniel P; Rood, Jennifer C; Martin, Corby K

    2016-07-01

    Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland-Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity.

  12. Energy Requirement Assessment in Japanese Table Tennis Players Using the Doubly Labeled Water Method.

    PubMed

    Sagayama, Hiroyuki; Hamaguchi, Genki; Toguchi, Makiko; Ichikawa, Mamiko; Yamada, Yosuke; Ebine, Naoyuki; Higaki, Yasuki; Tanaka, Hiroaki

    2017-10-01

    Total daily energy expenditure (TEE) and physical activity level (PAL) are important for adequate nutritional management in athletes. The PAL of table tennis has been estimated to about 2.0: it is categorized as a moderateactivity sport (4.0 metabolic equivalents [METs]) in the Compendium of Physical Activities. However, modern table tennis makes high physiological demands. The aims of the current study were to examine (1) TEE and PAL of competitive table tennis players and (2) the physiological demands of various types of table tennis practice. In Experiment 1, we measured TEE and PAL in 10 Japanese college competitive table tennis players (aged 19.9 ± 1.1 years) using the doubly labeled water (DLW) method during training and with an exercise training log and self-reported energy intake. TEE was 15.5 ± 1.9 MJ·day -1 (3695 ± 449 kcal·day -1 ); PAL was 2.53 ± 0.25; and the average training duration was 181 ± 38 min·day -1 . In Experiment 2, we measured METs of five different practices in seven college competition players (20.6 ± 1.2 years). Three practices without footwork were 4.5-5.2 METs, and two practices with footwork were 9.5-11.5 METs. Table tennis practices averaged 7.1 ± 3.2 METS demonstrating similarities with other vigorous racket sports. In conclusion the current Compendium of Physical Activities underestimates the physiological demands of table tennis practice for competition; the estimated energy requirement should be based on DLW method data.

  13. Anthelmintic effect of Psidium guajava and Tagetes erecta on wild-type and Levamisole-resistant Caenorhabditis elegans strains.

    PubMed

    Piña-Vázquez, Denia M; Mayoral-Peña, Zyanya; Gómez-Sánchez, Maricela; Salazar-Olivo, Luis A; Arellano-Carbajal, Fausto

    2017-04-18

    Psidium guajava and Tagetes erecta have been used traditionally to treat gastrointestinal parasites, but their active metabolites and mechanisms of action remain largely unknown. To evaluate the anthelmintic potential of Psidium guajava and Tagetes erecta extracts on Levamisole-sensitive and Levamisole-resistant strains of the model nematode Caenorhabditis elegans. Aqueous extracts of Psidium guajava (PGE) and Tagetes erecta (TEE) were assayed on locomotion and egg-laying behaviors of the wild-type (N2) and Levamisole-resistant (CB193) strains of Caenorhabditis elegans. Both extracts paralyzed wild-type and Levamisole-resistant nematodes in a dose-dependent manner. In wild-type worms, TEE 25mg/mL induced a 75% paralysis after 8h of treatment and PGE 25mg/mL induced a 100% paralysis after 4h of treatment. PGE exerted a similar paralyzing effect on N2 wild-type and CB193 Levamisole-resistant worms, while TEE only partially paralyzed CB193 worms. TEE 25mg/mL decreased N2 egg-laying by 65% with respect to the untreated control, while PGE did it by 40%. Psidium guajava leaves and Tagetes erecta flower-heads possess hydrosoluble compounds that block the motility of Caenorhabditis elegans by a mechanism different to that of the anthelmintic drug Levamisole. Effects are also observable on oviposition, which was diminished in the wild-type worms. The strong anthelmintic effects in crude extracts of these plants warrants future work to identify their active compounds and to elucidate their molecular mechanisms of action. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  14. Tricuspid Annular Geometry: A Three-Dimensional Transesophageal Echocardiographic Study

    PubMed Central

    Mahmood, Feroze; Kim, Han; Chaudary, Bilal; Bergman, Remco; Matyal, Robina; Gerstle, Jeniffer; Gorman, Joseph H.; Gorman, Robert C.; Khabbaz, Kamal R.

    2013-01-01

    Objective To demonstrate the clinical feasibility of accurately measuring tricuspid annular area by 3-dimensional (3D) transesophageal echocardiography (TEE) and to assess the geometric differences based on the presence of tricuspid regurgitation (TR). Also, the shape of the tricuspid annulus was compared with previous descriptions in the literature. Design Prospective. Setting Tertiary care university hospital. Interventions Three-dimensional TEE. Participants Patients undergoing cardiac surgery. Measurements and Main Results Volumetric data sets from 20 patients were acquired by 3D TEE and prospectively analyzed. Comparisons in annular geometry were made between groups based on the presence of TR. The QLab (Philips Medical Systems, Andover, MA) software package was used to calculate tricuspid annular area by both linear elliptical dimensions and planimetry. Further analyses were performed in the 4D Cardio-View (TomTec Corporation GmBH, Munich, Germany) and MATLAB (Natick, MA) software environments to accurately assess annular shape. It was found that patients with greater TR had an eccentrically dilated annulus with a larger annular area. Also, the area as measured by the linear ellipse method was overestimated as compared to the planimetry method. Furthermore, the irregular saddle-shaped geometry of the tricuspid annulus was confirmed through the mathematic model developed by the authors. Conclusions Three-dimensional TEE can be used to measure the tricuspid annular area in a clinically feasible fashion, with an eccentric dilation seen in patients with TR. The tricuspid annulus shape is complex, with annular high and low points, and annular area calculation based on linear measurements significantly overestimates 3D planimetered area. PMID:23725682

  15. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    PubMed

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  16. Patient-specific indirectly 3D printed mitral valves for pre-operative surgical modelling

    NASA Astrophysics Data System (ADS)

    Ginty, Olivia; Moore, John; Xia, Wenyao; Bainbridge, Dan; Peters, Terry

    2017-03-01

    Significant mitral valve regurgitation affects over 2% of the population. Over the past few decades, mitral valve (MV) repair has become the preferred treatment option, producing better patient outcomes than MV replacement, but requiring more expertise. Recently, 3D printing has been used to assist surgeons in planning optimal treatments for complex surgery, thus increasing the experience of surgeons and the success of MV repairs. However, while commercially available 3D printers are capable of printing soft, tissue-like material, they cannot replicate the demanding combination of echogenicity, physical flexibility and strength of the mitral valve. In this work, we propose the use of trans-esophageal echocardiography (TEE) 3D image data and inexpensive 3D printing technology to create patient specific mitral valve models. Patient specific 3D TEE images were segmented and used to generate a profile of the mitral valve leaflets. This profile was 3D printed and integrated into a mold to generate a silicone valve model that was placed in a dynamic heart phantom. Our primary goal is to use silicone models to assess different repair options prior to surgery, in the hope of optimizing patient outcomes. As a corollary, a database of patient specific models can then be used as a trainer for new surgeons, using a beating heart simulator to assess success. The current work reports preliminary results, quantifying basic morphological properties. The models were assessed using 3D TEE images, as well as 2D and 3D Doppler images for comparison to the original patient TEE data.

  17. The Sedentary Time and Activity Reporting Questionnaire (STAR-Q): Reliability and Validity Against Doubly Labeled Water and 7-Day Activity Diaries

    PubMed Central

    Csizmadi, Ilona; Neilson, Heather K.; Kopciuk, Karen A.; Khandwala, Farah; Liu, Andrew; Friedenreich, Christine M.; Yasui, Yutaka; Rabasa-Lhoret, Rémi; Bryant, Heather E.; Lau, David C. W.; Robson, Paula J.

    2014-01-01

    We determined measurement properties of the Sedentary Time and Activity Reporting Questionnaire (STAR-Q), which was designed to estimate past-month activity energy expenditure (AEE). STAR-Q validity and reliability were assessed in 102 adults in Alberta, Canada (2009–2011), who completed 14-day doubly labeled water (DLW) protocols, 7-day activity diaries on day 15, and the STAR-Q on day 14 and again at 3 and 6 months. Three-month reliability was substantial for total energy expenditure (TEE) and AEE (intraclass correlation coefficients of 0.84 and 0.73, respectively), while 6-month reliability was moderate. STAR-Q-derived TEE and AEE were moderately correlated with DLW estimates (Spearman's ρs of 0.53 and 0.40, respectively; P < 0.001), and on average, the STAR-Q overestimated TEE and AEE (median differences were 367 kcal/day and 293 kcal/day, respectively). Body mass index-, age-, sex-, and season-adjusted concordance correlation coefficients (CCCs) were 0.24 (95% confidence interval (CI): 0.07, 0.36) and 0.21 (95% CI: 0.11, 0.32) for STAR-Q-derived versus DLW-derived TEE and AEE, respectively. Agreement between the diaries and STAR-Q (metabolic equivalent-hours/day) was strongest for occupational sedentary time (adjusted CCC = 0.76, 95% CI: 0.64, 0.85) and overall strenuous activity (adjusted CCC = 0.64, 95% CI: 0.49, 0.76). The STAR-Q demonstrated substantial validity for estimating occupational sedentary time and strenuous activity and fair validity for ranking individuals by AEE. PMID:25038920

  18. Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

    NASA Technical Reports Server (NTRS)

    Jaber, W. A.; Prior, D. L.; Thamilarasan, M.; Grimm, R. A.; Thomas, J. D.; Klein, A. L.; Asher, C. R.

    2000-01-01

    BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

  19. Evaluation of the ability of three physical activity monitors to predict weight change and estimate energy expenditure

    PubMed Central

    Correa, John B.; Apolzan, John W.; Shepard, Desti N.; Heil, Daniel P.; Rood, Jennifer C.; Martin, Corby K.

    2016-01-01

    Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland–Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity. PMID:27270210

  20. Exercise Training and Energy Expenditure following Weight Loss

    PubMed Central

    Hunter, Gary R.; Fisher, Gordon; Neumeier, William H.; Carter, Stephen J.; Plaisance, Eric P.

    2015-01-01

    Purpose Determine the effects of aerobic or resistance training on activity related energy expenditure (AEE, kcal/d) and physical activity index (ARTE) following weight loss. It was hypothesized that weight loss without exercise training would be accompanied by a decrease in AEE, ARTE, and non-training physical activity energy expenditure (NEAT) and that exercise training would prevent decreases in free living energy expenditure. Methods 140 pre-menopausal women underwent an average of 25 pound weight loss during an 800 kcal/day diet of furnished food. One group aerobically trained 3 times/wk (40 min/d), another resistance trained 3 times/wk (10 exercises/2 sets x10 repetitions) and the third group did not exercise. DXA was used to measure body composition, indirect calorimetry to measure resting (REE) and walking energy expenditure, and doubly labeled water to measure total energy expenditure (TEE). AEE, ARTE, and non-training physical activity energy expenditure (NEAT) were calculated. Results TEE, REE, and NEAT all decreased following weight loss for the no exercise group, but not for the aerobic and resistance trainers. Only REE decreased in the two exercise groups. The resistance trainers increased ARTE. Heart rate and oxygen uptake while walking on the flat and up a grade were consistently related to TEE, AEE, NEAT, and ARTE. Conclusion Exercise training prevents a decrease in energy expenditure, including free living energy expenditure separate from the exercise training, following weight loss. Resistance training increased physical activity, while ease and economy in walking associates with increased TEE, AEE, NEAT, and ARTE. PMID:25606816

  1. Teeing Off With an Entirely New Material

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Liquidmetal(R) alloy is part of an entirely new class of vitrified metals, and is also known as metallic glass, or Vitreloy(R). A vitrified metal is a frozen liquid that fails to crystallize during solidification, unlike common metals such as titanium, steel, and aluminum. The technology takes the non-crystalline structure of glass and combines it with the properties of metal, a combination not found in nature, allowing for a product that offers the strength of a metal with the elasticity of a polymer. This unique technology is more than twice as strong as titanium and has a higher elastic limit. Liquidmetal(R) Golf presents this space-age development in a complete line golf clubs. Clubs made with this technology have a lower vibration response along with a softer, more solid feel. Because less energy is absorbed by the club's head upon impact, more energy is transferred directly to the ball. Vitreloy has potential commercial uses in sporting equipment: tennis rackets, bicycle frames, and baseball bats. The material may find applications in the medical industry for the manufacturing of surgical instruments and prosthetics. The Liquidmetal alloy is projected to replace many high performance materials, such as titanium, in the industries of aerospace, defense, military, automotives, medical instrumentation, and sporting goods

  2. Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

    PubMed

    da Silva, Cristina; Sahlen, Anders; Winter, Reidar; Bäck, Magnus; Rück, Andreas; Settergren, Magnus; Manouras, Aristomenis; Shahgaldi, Kambiz

    2014-12-01

    To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 ± 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 ± 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) ≤ 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.

  3. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    PubMed

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and

  4. Measurements of Daily Energy Intake and Total Energy Expenditure in People with Dementia in Care Homes: The Use of Wearable Technology.

    PubMed

    Murphy, J; Holmes, J; Brooks, C

    2017-01-01

    To estimate daily total energy expenditure (TEE) using a physical activity monitor, combined with dietary assessment of energy intake to assess the relationship between daily energy expenditure and patterns of activity with energy intake in people with dementia living in care homes. A cross-sectional study in care homes in the UK. Twenty residents with confirmed dementia diagnosis were recruited from two care homes that specialised in dementia care. A physical activity monitor (SensewearTM Armband, Body Media, Pittsburgh, PA) was employed to objectively determine total energy expenditure, sleep duration and physical activity. The armband was placed around the left upper triceps for up to 7 days. Energy intake was determined by weighing all food and drink items over 4 days (3 weekdays and 1 weekend day) including measurements of food wastage. The mean age was 78.7 (SD ± 11.8) years, Body Mass Index (BMI) 23.0 (SD ± 4.2) kg/m2; 50% were women. Energy intake (mean 7.4; SD ± 2.6) MJ/d) was correlated with TEE (mean 7.6; SD ± 1.8 MJ/d; r=0.49, p<0.05). Duration of sleeping ranged from 0.4-12.5 (mean 6.1) hrs/d and time spent lying down was 1.3-16.0 (8.3) hrs/d. On average residents spent 17.9 (6.3-23.4) hrs/d undertaking sedentary activity. TEE was correlated with BMI (r=0.52, p<0.05) and body weight (r=0.81, p<0.001) but inversely related to sleep duration (r=-0.59, p<0.01) and time lying down (r=-0.62, p<0.01). Multiple linear regression analysis revealed that after taking BMI, sleep duration and time spent lying down into account, TEE was no longer correlated with energy intake. The results show the extent to which body mass, variable activity and sleep patterns may be contributing to TEE and together with reduced energy intake, energy requirements were not satisfied. Thus wearable technology has the potential to offer real-time monitoring to provide appropriate nutrition management that is more person-centred to prevent weight loss in dementia.

  5. Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hatt, Charles R.; Tomkowiak, Michael T.; Dunkerley, David A. P.

    2015-12-15

    Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using amore » 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will

  6. Patent foramen ovale: detection with nongated multidetector CT.

    PubMed

    Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques

    2008-10-01

    To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.

  7. High resting metabolic rate among Amazonian forager-horticulturalists experiencing high pathogen burden

    PubMed Central

    Gurven, Michael D.; Trumble, Benjamin C.; Stieglitz, Jonathan; Yetish, Gandhi; Cummings, Daniel; Blackwell, Aaron D.; Beheim, Bret; Kaplan, Hillard S.; Pontzer, Herman

    2016-01-01

    Objectives Resting metabolic rate (RMR) reflects energetic costs of homeostasis and accounts for 60-75% of total energy expenditure (TEE). Lean mass and physical activity account for much RMR variability, but the impact of prolonged immune activation from infection on human RMR is unclear in naturalistic settings. We evaluate the effects of infection on mass-corrected RMR among Bolivian forager-horticulturalists, and assess whether RMR declines more slowly with age than in hygienic sedentary populations, as might be expected if older adults experience high pathogen burden. Materials and Methods RMR was measured by indirect calorimetry (Fitmate MED, Cosmed) in 1,300 adults aged 20-90 and TEE was measured using doubly labeled water (n= 40). Immune biomarkers, clinical diagnoses and anthropometrics were collected by the Tsimane Health and Life History Project. Results Tsimane have higher RMR and TEE than people in sedentary industrialized populations. Tsimane RMR is 18-47% (women) and 22-40% (men) higher than expected using six standard prediction equations. Tsimane mass-corrected TEE is similarly elevated compared to Westerners. Elevated leukocytes and helminths are associated with excess RMR in multivariate regressions, and jointly result in a predicted excess RMR of 10-15%. After age 40, RMR declines by 69 kcal/decade (p<0.0001). Controlling for lean mass and height accounts for 71% of age-related RMR decline, and adding indicators of infection minimally affects the age slope. The residual level of age-related decline from age 40 is 1.2% per decade. Conclusion High pathogen burden may lead to higher metabolic costs, which may be offset by smaller body mass or other energy-sparing mechanisms. PMID:27375044

  8. Periprocedural intracardiac echocardiography for left atrial appendage closure: a dual-center experience.

    PubMed

    Berti, Sergio; Paradossi, Umberto; Meucci, Francesco; Trianni, Giuseppe; Tzikas, Apostolos; Rezzaghi, Marco; Stolkova, Miroslava; Palmieri, Cataldo; Mori, Fabio; Santoro, Gennaro

    2014-09-01

    This dual-center study sought to demonstrate the utility and safety of intracardiac echocardiography (ICE) in providing adequate imaging guidance as an alternative to transesophageal echocardiography (TEE) during Amplatzer Cardiac Plug device implantation. Over 90% of intracardiac thrombi in atrial fibrillation originate from the left atrial appendage (LAA). Patients with contraindications to anticoagulation are potential candidates for LAA percutaneous occlusion. TEE is typically used to guide implantation. ICE-guided percutaneous LAA closure was performed in 121 patients to evaluate the following tasks typically achieved by TEE: assessment of the LAA dimension for device sizing; guidance of transseptal puncture; verification of the delivery sheath position; confirmation of location and stability of the device before and after release and continuous monitoring to detect procedural complications. In 51 consecutive patients, we compared the measurements obtained by ICE and fluoroscopy to choose the size of the device. The device was successfully implanted in 117 patients, yielding a technical success rate of 96.7%. Procedural success was achieved in 113 cases (93.4%). Four major adverse events (3 cardiac tamponades and 1 in-hospital transient ischemic attack) occurred. There was significant correlation in the measurements for device sizing assessed by angiography and ICE (r = 0.94, p < 0.0001). ICE imaging was able to perform the tasks typically provided by TEE during implantation of the Amplatzer Cardiac Plug device for LAA occlusion. Therefore, we provide evidence that the use of ICE offered accurate measurements of LAA dimension in order to select the correct device sizes. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy.

    PubMed

    Aquila, Iolanda; González, Ariana; Fernández-Golfín, Covadonga; Rincón, Luis Miguel; Casas, Eduardo; García, Ana; Hinojar, Rocio; Jiménez-Nacher, José Julio; Zamorano, José Luis

    2016-05-17

    3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.

  10. Exercise Training and Energy Expenditure following Weight Loss.

    PubMed

    Hunter, Gary R; Fisher, Gordon; Neumeier, William H; Carter, Stephen J; Plaisance, Eric P

    2015-09-01

    This study aims to determine the effects of aerobic or resistance training on activity-related energy expenditure (AEE; kcal·d(-1)) and physical activity index (activity-related time equivalent (ARTE)) following weight loss. It was hypothesized that weight loss without exercise training would be accompanied by decreases in AEE, ARTE, and nontraining physical activity energy expenditure (nonexercise activity thermogenesis (NEAT)) and that exercise training would prevent decreases in free-living energy expenditure. One hundred forty premenopausal women had an average weight loss of 25 lb during a diet (800 kcal·d(-1)) of furnished food. One group aerobically trained 3 times per week (40 min·d(-1)), another group resistance-trained 3 times per week (10 exercises/2 sets × 10 repetitions), and the third group did not exercise. Dual-energy x-ray absorptiometry was used to measure body composition, indirect calorimetry was used to measure resting energy expenditure (REE) and walking energy expenditure, and doubly labeled water was used to measure total energy expenditure (TEE). AEE, ARTE, and nontraining physical activity energy expenditure (NEAT) were calculated. TEE, REE, and NEAT all decreased following weight loss for the no-exercise group, but not for aerobic and resistance trainers. Only REE decreased in the two exercise groups. Resistance trainers increased ARTE. HR and oxygen uptake while walking on the flat and up a grade were consistently related to TEE, AEE, NEAT, and ARTE. Exercise training prevents a decrease in energy expenditure, including free-living energy expenditure separate from exercise training, following weight loss. Resistance training increases physical activity, whereas economy/ease of walking is associated with increased TEE, AEE, NEAT, and ARTE.

  11. Misreporting of energy intake in the elderly using doubly labeled water to measure total energy expenditure and weight change.

    PubMed

    Shahar, Danit R; Yu, Binbing; Houston, Denise K; Kritchevsky, Stephen B; Newman, Anne B; Sellmeyer, Deborah E; Tylavsky, Frances A; Lee, Jung Sun; Harris, Tamara B

    2010-02-01

    One of the major problems in dietary assessment is inaccuracy in reporting diet. To examine the association between self-reported energy intake (EI) by food frequency questionnaire (FFQ) and energy expenditure (EE), measured by doubly labeled water (DLW), among older persons. EE was assessed in 298 high-functioning, community-dwelling older adults (70-79 years of age) over a 2-week period using DLW. Dietary intake was assessed using a Block FFQ. The ratio between reported EI and total energy expenditure (TEE) was calculated. Misreporting was defined as follows: participants with an EI/TEE ratio of <0.77 were categorized as low energy reporters, while participants with an EI/TEE ratio >1.28 were categorized as high energy reporters. Participants with an EI/TEE ratio of 0.77-1.28 were categorized as "true" energy reporters. One-year percent weight change prior to EE visit was used as another validation indicator. Participants who were low energy reporters but lost >2% of their body weight were categorized as undereaters. Two hundred ninety-six participants provided both FFQ and DLW measurements. Forty-three percent of participants were low energy reporters; among them, almost 30% lost weight and, therefore, were categorized as undereaters. The undereaters consumed significantly fewer calories. No difference in the frequency of low energy reporting was detected between genders or racial groups. Underreporters had significantly higher body weight than "true" or high reporters. Undereaters tended to have higher body mass index than the underreporters. Undereating is prevalent in the elderly and may be falsely perceived as underreporting. It should be further addressed and characterized in future studies.

  12. The Rényi entanglement entropy of a general quantum dimer model at the RK point: a highly efficient algorithm.

    PubMed

    Pei, Jiquan; Han, Steve; Liao, Haijun; Li, Tao

    2014-01-22

    A highly efficient and simple-to-implement Monte Carlo algorithm is proposed for the evaluation of the Rényi entanglement entropy (REE) of the quantum dimer model (QDM) at the Rokhsar-Kivelson (RK) point. It makes possible the evaluation of REE at the RK point to the thermodynamic limit for a general QDM. We apply the algorithm to a QDM defined on the triangular and the square lattice in two dimensions and the simple and the face centered cubic (fcc) lattice in three dimensions. We find the REE on all these lattices follows perfect linear scaling in the thermodynamic limit, apart from an even-odd oscillation in the case of the square lattice. We also evaluate the topological entanglement entropy (TEE) with both a subtraction and an extrapolation procedure. We find the QDMs on both the triangular and the fcc lattice exhibit robust Z2 topological order. The expected TEE of ln2 is clearly demonstrated in both cases. Our large scale simulation also proves the recently proposed extrapolation procedure in cylindrical geometry to be a highly reliable way to extract the TEE of a topologically ordered system.

  13. Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography.

    PubMed

    Yu, Zili; Blaak, Sandra; Chang, Zu-yao; Yao, Jiajian; Bosch, Johan G; Prins, Christian; Lancée, Charles T; de Jong, Nico; Pertijs, Michiel A P; Meijer, Gerard C M

    2012-07-01

    There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-μm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.

  14. Primate energy expenditure and life history

    PubMed Central

    Pontzer, Herman; Raichlen, David A.; Gordon, Adam D.; Schroepfer-Walker, Kara K.; Hare, Brian; O’Neill, Matthew C.; Muldoon, Kathleen M.; Dunsworth, Holly M.; Wood, Brian M.; Isler, Karin; Burkart, Judith; Irwin, Mitchell; Shumaker, Robert W.; Lonsdorf, Elizabeth V.; Ross, Stephen R.

    2014-01-01

    Humans and other primates are distinct among placental mammals in having exceptionally slow rates of growth, reproduction, and aging. Primates’ slow life history schedules are generally thought to reflect an evolved strategy of allocating energy away from growth and reproduction and toward somatic investment, particularly to the development and maintenance of large brains. Here we examine an alternative explanation: that primates’ slow life histories reflect low total energy expenditure (TEE) (kilocalories per day) relative to other placental mammals. We compared doubly labeled water measurements of TEE among 17 primate species with similar measures for other placental mammals. We found that primates use remarkably little energy each day, expending on average only 50% of the energy expected for a placental mammal of similar mass. Such large differences in TEE are not easily explained by differences in physical activity, and instead appear to reflect systemic metabolic adaptation for low energy expenditures in primates. Indeed, comparisons of wild and captive primate populations indicate similar levels of energy expenditure. Broad interspecific comparisons of growth, reproduction, and maximum life span indicate that primates’ slow metabolic rates contribute to their characteristically slow life histories. PMID:24474770

  15. Fetal transesophageal echocardiography: clinical introduction as a monitoring tool during cardiac intervention in a human fetus.

    PubMed

    Kohl, T; Müller, A; Tchatcheva, K; Achenbach, S; Gembruch, U

    2005-12-01

    Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.

  16. Cutting efficiency of four different rotary nickel: Titanium instruments

    PubMed Central

    Cecchin, Doglas; de Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma; Gariba-Silva, Ricardo

    2011-01-01

    Aim: The aim of this study was to evaluate the cutting efficiency of rotary nickel-titanium (NiTi) instruments K3, NiTi Tee, Profile, and Quantec with taper size 04/25. Materials and Methods: The number of samples was 10 for each group (n = 10). The cutting efficiency was measured by the mass loss from each acrylic resin block after instrumentation of a simulated canal using the Crown-down technique. Results: The analysis of variance (ANOVA) showed that there was a statistically significant difference among the studied groups. The Tukey's test showed that the acrylic resin blocks prepared with instruments K3 (0.00369 ± 0.00022), NiTi Tee (0.00368 ± 0.00023), and Profile (0.00351 ± 0.00026) presented the greatest mass loss, showing no statistically significant difference among them (P < 0.05). The lowest mass loss was found in the blocks prepared with Quantec instruments (0.00311 ± 0.0003) (P < 0.05). Conclusions: It could be concluded that the K3, NiTi Tee, and Profile instruments presented a greater cutting efficiency than the Quantec instruments. PMID:21814349

  17. Minnesota leisure time activity questionnaire and doubly labeled water in adolescents.

    PubMed

    Slinde, Frode; Arvidsson, Daniel; Sjöberg, Agneta; Rossander-Hulthén, Lena

    2003-11-01

    To validate the energy expenditure estimated from The Minnesota Leisure Time Physical Activity Questionnaire (MLTPAQ) with total energy expenditure (TEE) measured by doubly labeled water (DLW), and to present and examine the validity of an extended version of the MLTPAQ with additional questions about inactivity during leisure time (eMLTPAQ), in a sample of Swedish 15-yr-old adolescents. Thirty-five 15-yr-old adolescents were interviewed using the eMLTPAQ. In addition to anthropometry, indirect calorimetry was measured to assess basal metabolic rate, and TEE was assessed by the DLW method over a 14-d period. Energy expenditure calculated from MLTPAQ correlated well with TEEDLW (r=0.49, P<0.01), and the correlation increased when including questions about inactivity (r=0.73, P<0.01). However, eMLTPAQ underestimated TEE in 34 of the 35 students, with a mean difference between the methods of 2.8 MJ.d(-1) (95% limits of agreement: -0.1 to 5.6 MJ.d(-1)), which mainly was explained by a relative high intensity in the time which remained unreported. eMLTPAQ is valid in ranking adolescents energy expenditure and in describing patterns of leisure time physical activities.

  18. A Protocol for Diagnosis and Management of Aortic Atherosclerosis in Cardiac Surgery Patients

    PubMed Central

    Brandon Bravo Bruinsma, George J.; Van 't Hof, Arnoud W. J.; Grandjean, Jan G.; Nierich, Arno P.

    2017-01-01

    In patients undergoing cardiac surgery, use of perioperative screening for aortic atherosclerosis with modified TEE (A-View method) was associated with lower postoperative mortality, but not stroke, as compared to patients operated on without such screening. At the time of clinical implementation and validation, we did not yet standardize the indications for modified TEE and the changes in patient management in the presence of aortic atherosclerosis. Therefore, we designed a protocol, which combined the diagnosis of atherosclerosis of thoracic aorta and the subsequent considerations with respect to the intraoperative management and provides a systematic approach to reduce the risk of cerebral complications. PMID:28852575

  19. Diagnostic significance of three-dimensional echocardiography in asymptomatic unicuspid aortic valve.

    PubMed

    Mladenovic, Zorica; Vranes, Danijela; Obradovic, Slobodan; Dzudovic, Boris; Angelkov Ristic, Andjelka; Ratkovic, Nenad; Jovic, Zoran; Spasic, Marijan; Maric Kocijancic, Jelena; Djruic, Predrag

    2018-06-04

    Unicuspid aortic valve (UAV) is a rare congenital anomaly of aorta associated with a faster progress of valvular dysfunction, aortic dilatation and with necessity for more frequent controls and precise evaluation Asymptomatic 35 year old man had abnormal systolic diastolic murmur on aortic valve during routine examination. Initial diagnostic with transthoracic echocardiography (TTE) supposed bicuspid aortic valve, while three-dimensional transesophageal echocardiography (3D TEE) and multidetector computed tomography defined unicuspid, unicomissural aortic valve with moderate aortic stenosis and regurgitation. This case report confirmed that 3D TEE gives us opportunity for early, improved and precise diagnosis of UAV. © 2018 Wiley Periodicals, Inc.

  20. Gerbode defect and multivalvular dysfunction: Complex complications in adult congenital heart disease.

    PubMed

    Ruivo, Catarina; Guardado, Joana; Montenegro Sá, Fernando; Saraiva, Fátima; Antunes, Alexandre; Correia, Joana; Morais, João

    2017-07-01

    We report a clinical case of a 40-year-old male with surgically corrected congenital heart disease (CHD) 10 years earlier: closure of ostium primum, mitral annuloplasty, and aortic valve and root surgery. The patient was admitted with acute heart failure. Transesophageal echocardiography (TEE) revealed a dysmorphic and severely incompetent aortic valve, a partial tear of the mitral valve cleft repair and annuloplasty ring dehiscence. A true left ventricular-to-right atrial shunt confirmed a direct Gerbode defect. The authors aim to discuss the diagnostic challenge of adult CHD, namely the key role of TEE on septal defects and valve regurgitations description. © 2017, Wiley Periodicals, Inc.

  1. Detection of right-to-left shunts: comparison between the International Consensus and Spencer Logarithmic Scale criteria.

    PubMed

    Lao, Annabelle Y; Sharma, Vijay K; Tsivgoulis, Georgios; Frey, James L; Malkoff, Marc D; Navarro, Jose C; Alexandrov, Andrei V

    2008-10-01

    International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.

  2. Validity of hip-mounted uniaxial accelerometry with heart-rate monitoring vs. triaxial accelerometry in the assessment of free-living energy expenditure in young children: the IDEFICS Validation Study.

    PubMed

    Ojiambo, Robert; Konstabel, Kenn; Veidebaum, Toomas; Reilly, John; Verbestel, Vera; Huybrechts, Inge; Sioen, Isabelle; Casajús, José A; Moreno, Luis A; Vicente-Rodriguez, German; Bammann, Karin; Tubic, Bojan M; Marild, Staffan; Westerterp, Klaas; Pitsiladis, Yannis P

    2012-11-01

    One of the aims of Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants (IDEFICS) validation study is to validate field measures of physical activity (PA) and energy expenditure (EE) in young children. This study compared the validity of uniaxial accelerometry with heart-rate (HR) monitoring vs. triaxial accelerometry against doubly labeled water (DLW) criterion method for assessment of free-living EE in young children. Forty-nine European children (25 female, 24 male) aged 4-10 yr (mean age: 6.9 ± 1.5 yr) were assessed by uniaxial ActiTrainer with HR, uniaxial 3DNX, and triaxial 3DNX accelerometry. Total energy expenditure (TEE) was estimated using DLW over a 1-wk period. The longitudinal axis of both devices and triaxial 3DNX counts per minute (CPM) were significantly (P < 0.05) associated with physical activity level (PAL; r = 0.51 ActiTrainer, r = 0.49 uniaxial-3DNX, and r = 0.42 triaxial Σ3DNX). Eight-six percent of the variance in TEE could be predicted by a model combining body mass (partial r(2) = 71%; P < 0.05), CPM-ActiTrainer (partial r(2) = 11%; P < 0.05), and difference between HR at moderate and sedentary activities (ModHR - SedHR) (partial r(2) = 4%; P < 0.05). The SE of TEE estimate for ActiTrainer and 3DNX models ranged from 0.44 to 0.74 MJ/days or ∼7-11% of the average TEE. The SE of activity-induced energy expenditure (AEE) model estimates ranged from 0.38 to 0.57 MJ/day or 24-26% of the average AEE. It is concluded that the comparative validity of hip-mounted uniaxial and triaxial accelerometers for assessing PA and EE is similar.

  3. Wearable cameras can reduce dietary under-reporting: doubly labelled water validation of a camera-assisted 24 h recall.

    PubMed

    Gemming, Luke; Rush, Elaine; Maddison, Ralph; Doherty, Aiden; Gant, Nicholas; Utter, Jennifer; Ni Mhurchu, Cliona

    2015-01-28

    Preliminary research has suggested that wearable cameras may reduce under-reporting of energy intake (EI) in self-reported dietary assessment. The aim of the present study was to test the validity of a wearable camera-assisted 24 h dietary recall against the doubly labelled water (DLW) technique. Total energy expenditure (TEE) was assessed over 15 d using the DLW protocol among forty adults (n 20 males, age 35 (sd 17) years, BMI 27 (sd 4) kg/m2 and n 20 females, age 28 (sd 7) years, BMI 22 (sd 2) kg/m2). EI was assessed using three multiple-pass 24 h dietary recalls (MP24) on days 2-4, 8-10 and 13-15. On the days before each nutrition assessment, participants wore an automated wearable camera (SenseCam (SC)) in free-living conditions. The wearable camera images were viewed by the participants following the completion of the dietary recall, and their changes in self-reported intakes were recorded (MP24+SC). TEE and EI assessed by the MP24 and MP24+SC methods were compared. Among men, the MP24 and MP24+SC measures underestimated TEE by 17 and 9%, respectively (P< 0.001 and P= 0.02). Among women, these measures underestimated TEE by 13 and 7%, respectively (P< 0.001 and P= 0.004). The assistance of the wearable camera (MP24+SC) reduced the magnitude of under-reporting by 8% for men and 6% for women compared with the MP24 alone (P< 0.001 and P< 0.001). The increase in EI was predominantly from the addition of 265 unreported foods (often snacks) as revealed by the participants during the image review. Wearable cameras enhance the accuracy of self-report by providing passive and objective information regarding dietary intake. High-definition image sensors and increased imaging frequency may improve the accuracy further.

  4. Low Energy Turnover of Physically Inactive Participants as a Determinant of Insufficient Mineral and Vitamin Intake in NHANES

    PubMed Central

    Heydenreich, Juliane; Melzer, Katarina; Flury, Céline

    2017-01-01

    Micronutrient requirements do not scale linearly with physical activity-related energy expenditure (AEE). Inactive persons may have insufficient micronutrient intake because of low energy intake (EI). We extracted data from NHANES 2003–2006 on 4015 adults (53 ± 18 years (mean ± SD), 29 ± 6 kg/m2, 48% women) with valid physical activity (accelerometry) and food intake (2 × 24 h-dietary recall) measures. Total energy expenditure (TEE) was estimated by summing the basal metabolic rate (BMR, Harris-Benedict), AEE, and 10% of TEE for the thermic effect of food, to calculate the physical activity levels (PAL = TEE/BMR). Energy intake (EI) was scaled to match TEE assuming energy balance. Adjusted food intake was then analyzed for energy and micronutrient content and compared to estimated average requirements. The NHANES population was physically insufficiently active. There were 2440 inactive (PAL < 1.4), 1469 lightly to moderately active (PAL1.4 < 1.7), 94 sufficiently active (PAL1.7 < 2.0), and 12 very active participants (PAL ≥ 2.0). The inactive vs. active had significantly lower intake for all micronutrients apart from vitamin A, B12, C, K, and copper (p < 0.05). The inactive participants had insufficient intake for 6/19 micronutrients, while the active participants had insufficient intake for 5/19 (p < 0.05) micronutrients. Multiple linear regression indicated a lower risk for insufficient micronutrient intake for participants with higher PAL and BMI (p < 0.001). Symmetrical up-scaling of PAL and EI to recommended physical activity levels reduced the frequency of micronutrient insufficiencies. It follows that prevalence of insufficient micronutrient intake from food in NHANES might be partly determined by low energy turnover from insufficient PAL. PMID:28708118

  5. The Sedentary Time and Activity Reporting Questionnaire (STAR-Q): reliability and validity against doubly labeled water and 7-day activity diaries.

    PubMed

    Csizmadi, Ilona; Neilson, Heather K; Kopciuk, Karen A; Khandwala, Farah; Liu, Andrew; Friedenreich, Christine M; Yasui, Yutaka; Rabasa-Lhoret, Rémi; Bryant, Heather E; Lau, David C W; Robson, Paula J

    2014-08-15

    We determined measurement properties of the Sedentary Time and Activity Reporting Questionnaire (STAR-Q), which was designed to estimate past-month activity energy expenditure (AEE). STAR-Q validity and reliability were assessed in 102 adults in Alberta, Canada (2009-2011), who completed 14-day doubly labeled water (DLW) protocols, 7-day activity diaries on day 15, and the STAR-Q on day 14 and again at 3 and 6 months. Three-month reliability was substantial for total energy expenditure (TEE) and AEE (intraclass correlation coefficients of 0.84 and 0.73, respectively), while 6-month reliability was moderate. STAR-Q-derived TEE and AEE were moderately correlated with DLW estimates (Spearman's ρs of 0.53 and 0.40, respectively; P < 0.001), and on average, the STAR-Q overestimated TEE and AEE (median differences were 367 kcal/day and 293 kcal/day, respectively). Body mass index-, age-, sex-, and season-adjusted concordance correlation coefficients (CCCs) were 0.24 (95% confidence interval (CI): 0.07, 0.36) and 0.21 (95% CI: 0.11, 0.32) for STAR-Q-derived versus DLW-derived TEE and AEE, respectively. Agreement between the diaries and STAR-Q (metabolic equivalent-hours/day) was strongest for occupational sedentary time (adjusted CCC = 0.76, 95% CI: 0.64, 0.85) and overall strenuous activity (adjusted CCC = 0.64, 95% CI: 0.49, 0.76). The STAR-Q demonstrated substantial validity for estimating occupational sedentary time and strenuous activity and fair validity for ranking individuals by AEE. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. A low-dose, dual-phase cardiovascular CT protocol to assess left atrial appendage anatomy and exclude thrombus prior to left atrial intervention.

    PubMed

    Lazoura, Olga; Ismail, Tevfik F; Pavitt, Christopher; Lindsay, Alistair; Sriharan, Mona; Rubens, Michael; Padley, Simon; Duncan, Alison; Wong, Tom; Nicol, Edward

    2016-02-01

    Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.

  7. Incidence, Characteristics, and Clinical Course of Device-Related Thrombus After Watchman Left Atrial Appendage Occlusion Device Implantation in Atrial Fibrillation Patients.

    PubMed

    Kubo, Shunsuke; Mizutani, Yukiko; Meemook, Krissada; Nakajima, Yoshifumi; Hussaini, Asma; Kar, Saibal

    2017-12-11

    This study investigated characteristics and clinical impact of device-related thrombus formation after Watchman device implantation in atrial fibrillation (AF) patients. Left atrial appendage occlusion using the Watchman device is an effective alternative to anticoagulation for stroke prevention in AF patients. However, device-related thrombus formation remains an important concern after Watchman implantation. From 2006 to 2014, 119 consecutive AF patients underwent Watchman implantation. Transesophageal echocardiographic (TEE) follow-up was scheduled at 45 days, at 6 months, and at 12 months after the procedure. The incidence, characteristics, and clinical course of device-related thrombus formation detected by TEE were assessed. Follow-up TEE identified thrombus formation on the Watchman device in 4 patients (3.4%). The prevalence of chronic AF was 100% in patients with thrombus, which was higher than that for patients without thrombus (40.0%). Deployed device size was numerically larger in patients with thrombus (29.3 ± 3.8 mm vs. 25.7 ± 3.2 mm, respectively). All patients with thrombus discontinued any of the anticoagulant/antiplatelet therapy which was required under the study protocol. After restarting or continuing warfarin and aspirin therapy, complete resolution of the thrombus was achieved in all patients at subsequent follow-up TEE. Warfarin therapy was discontinued within 6 months for all cases, and there was no thrombus recurrence. The mean follow-up duration was 1,456 ± 546 days, with no death, stroke, or systemic embolization events in patients with thrombus. AF burden, device size, and anticoagulant/antiplatelet regimens can be associated with device-related thrombus after Watchman device implantation. Short-term warfarin therapy was effective, and the clinical outcomes were favorable. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  8. Transesophageal echocardiographic evaluation of baboons during microgravity induced by parabolic flight

    NASA Technical Reports Server (NTRS)

    Vernalis, Marina N.; Latham, Ricky D.; Fanton, John W.; Geffney, F. Andrew

    1993-01-01

    Transthoracic echocardiography (TTE) is a feasible method to noninvasively examine cardiac anatomy during parabolic flight. However, transducer placement on the chest wall is very difficult to maintain during transition to microgravity. In addition, TTE requires the use of low frequency transponders which limit resolution. Transesophical echocardiography (TEE) is an established imaging technique which obtains echocardiographic information from the esophagus. It is a safe procedure and provides higher quality images of cardiac structure than obtained with TTE. This study is designed to determine whether TEE was feasible to perform during parabolic flight and to determine whether acute central volume responses occur in acute transition to zero gravity by direct visualization of the cardiac chambers.

  9. Profound Obstructive Hypotension From Prone Positioning Documented by Transesophageal Echocardiography in a Patient With Scoliosis: A Case Report.

    PubMed

    Abcejo, Arnoley S; Diaz Soto, Juan; Castoro, Courtney; Armour, Sarah; Long, Timothy R

    2017-08-01

    In a healthy 12-year-old female with scoliosis, prone positioning resulted in pressor-refractory cardiovascular collapse. Resumption of supine position immediately improved hemodynamics. Intraoperative transesophageal echocardiography (TEE) revealed a collapsed left atrium and biventricular failure. Repeat prone positioning resulted in a recurrence of hypotension. However, hemodynamic stabilization was restored and maintained by repositioning chest pads caudally. The patient successfully underwent a 6-hour scoliosis repair without perioperative morbidity. With this case, we aim to: (1) reintroduce awareness of this mechanical obstructive cause of reversible hypotension; (2) highlight the use of intraoperative TEE during prone hemodynamic collapse; and (3) suggest an alternative prone positioning technique if chest compression results in hemodynamic instability.

  10. [Fever, atrial fibrillation, and angina pectoris in a 58-year-old man].

    PubMed

    Groebner, M; Südhoff, T; Doering, M; Kirmayer, M; Nitsch, T; Prügl, L; Römer, W; Wolf, H; Tacke, J; Massoudy, P; Nüsse, T; Elsner, D

    2014-05-01

    Primary cardiac lymphoma (PCL) respresents a very rare type of cardiac tumour. This report illustrates a case of PCL in an immunocompetent 58-year-old man presenting with atrial fibrillation and febrile syndrome. Comprehensive imaging [computer tomography (CT), cardiac magnetic resonance imaging (cMRI), 3-dimensional transesophageal echocardiography (3D-TEE)] identified a large right atrial tumour, leading to pericardial effusion. Isolated cardiac involvement was confirmed by positron emission tomography (PET)-CT. A diffuse large B-cell lymphoma (DLBCL) was diagnosed based on the results of a TEE-guided biopsy. A normalized PET scan (PETAL study) indicated complete remission following R-CHOP 14 immunochemotherapy. Thus, an interdisciplinary and multimodal approach avoided unnecessary cardiac surgery.

  11. Alternative Physics Examination Questions: Identification and Explanation of Different Discriminating Powers

    NASA Astrophysics Data System (ADS)

    Forster, Patricia A.

    2005-12-01

    The issue of unfairness arises in high-stakes public examinations when students choose questions from alternatives that are offered and marks on the alternatives turn out to be discrepant. This paper addresses and defines unfairness and discrepancy in the context of alternative questions in Physics Tertiary Entrance Examinations (TEE) in Western Australia. As well, I present an analysis of question characteristics that explain observed marks-differences. The characteristics mainly relate to the construction of the text of questions, the detail on diagrams, and requirements for calculation. The list of characteristics could inform the setting of compulsory as well as alternative examination questions. The paper includes a brief exploration of results by gender on the alternative Physics TEE questions.

  12. PTSD in Children and Teens

    MedlinePlus

    ... Adaptive Sports Program Creative Arts Festival Golden Age Games Summer Sports Clinic Training - Exposure - Experience (TEE) Tournament Wheelchair Games Winter Sports Clinic Locations Hospitals & Clinics Vet Centers ...

  13. Center for Women Veterans

    MedlinePlus

    ... Adaptive Sports Program Creative Arts Festival Golden Age Games Summer Sports Clinic Training - Exposure - Experience (TEE) Tournament Wheelchair Games Winter Sports Clinic Locations Hospitals & Clinics Vet Centers ...

  14. Federal Benefits for Veterans, Dependents and Survivors: 2017 Online Edition

    MedlinePlus

    ... Adaptive Sports Program Creative Arts Festival Golden Age Games Summer Sports Clinic Training - Exposure - Experience (TEE) Tournament Wheelchair Games Winter Sports Clinic Locations Hospitals & Clinics Vet Centers ...

  15. For Homeless Veterans

    MedlinePlus

    ... Adaptive Sports Program Creative Arts Festival Golden Age Games Summer Sports Clinic Training - Exposure - Experience (TEE) Tournament Wheelchair Games Winter Sports Clinic Locations Hospitals & Clinics Vet Centers ...

  16. [Periprocedural and late complications after percutaneous closure of patent foramen ovale: a single centre experience].

    PubMed

    Węglarz, Przemysław; Konarska Kuszewska, Ewa; Spisak Borowska, Katarzyna; Machowski, Jerzy; Drzewiecka-Gerber, Agnieszka; Kuszewski, Piotr; Jackson, Christopher L; Opala, Grzegorz; Trusz Gluza, Maria

    2012-01-01

    Patent foramen ovale (PFO) is a potential risk factor for ischaemic stroke in young individuals. An interventional method of secondary stroke prevention in PFO patients is its percutaneous closure. To assess safety and effectiveness (i.e. lack of residual shunt) of percutaneous PFO closure in patients with history of cryptogenic cerebrovascular event. 149 patients (56 men/93 women), aged 39 ± 12 years, underwent percutaneous PFO closure. The implantation was performed under local anaesthesia, guided by trans-oesophageal echocardiography (TEE) and fluoroscopy. Follow-up trans-thoracic echocardiography (TTE) was performed at 1 month and follow-up TEE at 6-months. In cases of residual shunt, additional TEE was performed after ensuing 6 months. Effective PFO closure (no residual shunt) was achieved in 91.3% patients at 6 months and 95.3% patients at 12 months. In 2 patients transient atrial fibrillation was observed during the procedure. In 2 patients, a puncture site haematoma developed and in 1 patient superficial thrombophlebitis was noted. In 1 patient a small pericardial effusion was observed, which resolved at day 3 post-procedurally, after administration of non-steroidal anti-inflammatory drugs. Percutaneous PFO closure seems to be a safe procedure when performed in a centre with adequate expertise with regard to these procedures.

  17. Rationale and design of the EPISTEME trial: efficacy of post-stroke intensive rosuvastatin treatment for aortogenic embolic stroke.

    PubMed

    Ueno, Yuji; Yamashiro, Kazuo; Tanaka, Yasutaka; Watanabe, Masao; Shimada, Yoshiaki; Kuroki, Takuma; Miyamoto, Nobukazu; Daimon, Masao; Tanaka, Ryota; Miyauchi, Katsumi; Daida, Hiroyuki; Hattori, Nobutaka; Urabe, Takao

    2014-02-01

    Large atheromatous aortic plaques (AAPs) are associated with stroke recurrence. Rosuvastatin is a potent lipid-lowering agent and suppresses carotid and coronary artery atherosclerosis. It is unclear whether rosuvastatin has anti-atherogenic effects against AAPs in stroke patients. We designed a clinical trial in stroke patients to analyze changes in AAPs after rosuvastatin treatment using repeated transesophageal echocardiography (TEE). This trial is a prospective randomized open label study. Inclusion criteria were patients were ischemic stroke with hypercholesterolemia and AAPs ≥ 4 mm in thickness. The patients are randomly assigned to either a group treated with 5 mg/day rosuvastatin or a control group. Primary endpoint is the changes in volume and composition of AAPs after 6 months using transesophageal echocardiography (TEE). Biochemical findings are analyzed. By using repeated TEE and binary image analysis, we will be able to compare the dynamic changes in plaque composition of AAPs before and after therapy in the two groups. The EPISTEME trial will provide information on the changes in plaque volume and composition achieved by improvement of lipid profiles with rosuvastatin therapy in stroke patients with aortic atherosclerosis. The results of the study may provide evidence for a therapeutic strategy for aortogenic brain embolism. This study is registered with UMIN-CTR (UMIN000010548).

  18. Development of an accelerometer-based multivariate model to predict free-living energy expenditure in a large military cohort.

    PubMed

    Horner, Fleur; Bilzon, James L; Rayson, Mark; Blacker, Sam; Richmond, Victoria; Carter, James; Wright, Anthony; Nevill, Alan

    2013-01-01

    This study developed a multivariate model to predict free-living energy expenditure (EE) in independent military cohorts. Two hundred and eighty-eight individuals (20.6 ± 3.9 years, 67.9 ± 12.0 kg, 1.71 ± 0.10 m) from 10 cohorts wore accelerometers during observation periods of 7 or 10 days. Accelerometer counts (PAC) were recorded at 1-minute epochs. Total energy expenditure (TEE) and physical activity energy expenditure (PAEE) were derived using the doubly labelled water technique. Data were reduced to n = 155 based on wear-time. Associations between PAC and EE were assessed using allometric modelling. Models were derived using multiple log-linear regression analysis and gender differences assessed using analysis of covariance. In all models PAC, height and body mass were related to TEE (P < 0.01). For models predicting TEE (r (2) = 0.65, SE = 462 kcal · d(-1) (13.0%)), PAC explained 4% of the variance. For models predicting PAEE (r (2) = 0.41, SE = 490 kcal · d(-1) (32.0%)), PAC accounted for 6% of the variance. Accelerometry increases the accuracy of EE estimation in military populations. However, the unique nature of military life means accurate prediction of individual free-living EE is highly dependent on anthropometric measurements.

  19. 23-year experience on diagnosis and surgical treatment of benign and malignant cardiac tumors.

    PubMed

    Kośmider, Anna; Jaszewski, Ryszard; Marcinkiewicz, Anna; Bartczak, Karol; Knopik, Jerzy; Ostrowski, Stanisław

    2013-10-31

    Although myxoma is the most frequent cardiac tumor, other conditions should be taken into consideration in the differential diagnosis. Transthoracic echocardiography (TTE), followed by transesophageal echocardiography (TEE) remain the principal methods for cardiac tumor screening and visualizing. The aim of the study was to compare the diagnostics, surgical treatment and prognosis of malignant and benign cardiac tumors. From 1986 to 2009 there were 121 patients with cardiac tumors operated on in the Cardiac Surgery Clinic of the Medical University in Lodz. Patients were referred to surgery mainly on the basis of the TTE and TEE image. In 4 cases valvular prosthesis implantation or valve repair were carried out. Patients remained under long-term observation in the Cardiac Surgery Outpatient Clinic. Myxoma was diagnosed in 114 cases. Malignancies were discovered in 7 cases. The left atrium was the most frequent localization. The echocardiographic image differed significantly in benign and malignant tumors. The postoperative period was complicated by embolic events or myocardial infarctions. Only malignant tumors were associated with mortality due to cardiovascular events. The survival for malignant tumors was significantly shorter. Short and long-term results of operative treatment are very good for benign tumors in contrast to cardiac malignancies. The TTE and TEE image can be very significant in the final diagnosis.

  20. Metabolic acceleration and the evolution of human brain size and life history.

    PubMed

    Pontzer, Herman; Brown, Mary H; Raichlen, David A; Dunsworth, Holly; Hare, Brian; Walker, Kara; Luke, Amy; Dugas, Lara R; Durazo-Arvizu, Ramon; Schoeller, Dale; Plange-Rhule, Jacob; Bovet, Pascal; Forrester, Terrence E; Lambert, Estelle V; Thompson, Melissa Emery; Shumaker, Robert W; Ross, Stephen R

    2016-05-19

    Humans are distinguished from the other living apes in having larger brains and an unusual life history that combines high reproductive output with slow childhood growth and exceptional longevity. This suite of derived traits suggests major changes in energy expenditure and allocation in the human lineage, but direct measures of human and ape metabolism are needed to compare evolved energy strategies among hominoids. Here we used doubly labelled water measurements of total energy expenditure (TEE; kcal day(-1)) in humans, chimpanzees, bonobos, gorillas and orangutans to test the hypothesis that the human lineage has experienced an acceleration in metabolic rate, providing energy for larger brains and faster reproduction without sacrificing maintenance and longevity. In multivariate regressions including body size and physical activity, human TEE exceeded that of chimpanzees and bonobos, gorillas and orangutans by approximately 400, 635 and 820 kcal day(-1), respectively, readily accommodating the cost of humans' greater brain size and reproductive output. Much of the increase in TEE is attributable to humans' greater basal metabolic rate (kcal day(-1)), indicating increased organ metabolic activity. Humans also had the greatest body fat percentage. An increased metabolic rate, along with changes in energy allocation, was crucial in the evolution of human brain size and life history.

  1. 75 FR 25321 - Agency Information Collection (VA National Rehabilitation Special Events, Event Registration...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... Clinic Application, VA Form 0928a series. f. National Veterans Creative Arts Festival Application, VA... Veterans Creative Arts Festival, National Veterans TEE Tournament, National Disabled Veterans Winter Sports...

  2. Developing Successful Community Partnerships: "Teeing Up" for Change.

    ERIC Educational Resources Information Center

    Tyler, Arthur Q.

    2002-01-01

    Reports that thinking innovatively and taking prudent risks to bring a golf driving range to Los Angeles City College (California) helped unite the community with the college. Chronicles the long-term and complex partnership process behind this development, which led to a change in campus culture and reinvigorated the campus and community…

  3. Making three-dimensional echocardiography more tangible: a workflow for three-dimensional printing with echocardiographic data.

    PubMed

    Mashari, Azad; Montealegre-Gallegos, Mario; Knio, Ziyad; Yeh, Lu; Jeganathan, Jelliffe; Matyal, Robina; Khabbaz, Kamal R; Mahmood, Feroze

    2016-12-01

    Three-dimensional (3D) printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping) derived from 3D transesophageal echocardiography (TEE) has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology. © 2016 The authors.

  4. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    PubMed Central

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  5. 98. DETAIL VIEW OF STORM DAMAGE AND EXPOSED SUBSTRUCTURE, NORTHWEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. DETAIL VIEW OF STORM DAMAGE AND EXPOSED SUBSTRUCTURE, NORTHWEST SIDE OF 4TH TEE, LOOKING WEST - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  6. Energy expenditure in caving

    PubMed Central

    Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio

    2017-01-01

    The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225–287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000–1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue. PMID:28158208

  7. Reported Energy Intake Accuracy Compared to Doubly Labeled Water and Usability of the Mobile Food Record among Community Dwelling Adults.

    PubMed

    Boushey, Carol J; Spoden, Melissa; Delp, Edward J; Zhu, Fengqing; Bosch, Marc; Ahmad, Ziad; Shvetsov, Yurii B; DeLany, James P; Kerr, Deborah A

    2017-03-22

    The mobile Food Record (mFR) is an image-based dietary assessment method for mobile devices. The study primary aim was to test the accuracy of the mFR by comparing reported energy intake (rEI) to total energy expenditure (TEE) using the doubly labeled water (DLW) method. Usability of the mFR was assessed by questionnaires before and after the study. Participants were 45 community dwelling men and women, 21-65 years. They were provided pack-out meals and snacks and encouraged to supplement with usual foods and beverages not provided. After being dosed with DLW, participants were instructed to record all eating occasions over a 7.5 days period using the mFR. Three trained analysts estimated rEI from the images sent to a secure server. rEI and TEE correlated significantly (Spearman correlation coefficient of 0.58, p < 0.0001). The mean percentage of underreporting below the lower 95% confidence interval of the ratio of rEI to TEE was 12% for men (standard deviation (SD) ± 11%) and 10% for women (SD ± 10%). The results demonstrate the accuracy of the mFR is comparable to traditional dietary records and other image-based methods. No systematic biases could be found. The mFR was received well by the participants and usability was rated as easy.

  8. A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study.

    PubMed

    Mahmoud, Hani M; Al-Ghamdi, Mohammed A; Ghabashi, Abdullah E; Anwar, Ashraf M

    2015-01-01

    Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90) was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA) aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9 ± 1.6 seconds. The time-to-tent was 64.8 ± 16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

  9. Energy expenditure in caving.

    PubMed

    Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio; Rinaldi, Andrea C

    2017-01-01

    The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225-287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000-1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue.

  10. 23-year experience on diagnosis and surgical treatment of benign and malignant cardiac tumors

    PubMed Central

    Jaszewski, Ryszard; Marcinkiewicz, Anna; Bartczak, Karol; Knopik, Jerzy; Ostrowski, Stanisław

    2013-01-01

    Introduction Although myxoma is the most frequent cardiac tumor, other conditions should be taken into consideration in the differential diagnosis. Transthoracic echocardiography (TTE), followed by transesophageal echocardiography (TEE) remain the principal methods for cardiac tumor screening and visualizing. The aim of the study was to compare the diagnostics, surgical treatment and prognosis of malignant and benign cardiac tumors. Material and methods From 1986 to 2009 there were 121 patients with cardiac tumors operated on in the Cardiac Surgery Clinic of the Medical University in Lodz. Patients were referred to surgery mainly on the basis of the TTE and TEE image. In 4 cases valvular prosthesis implantation or valve repair were carried out. Patients remained under long-term observation in the Cardiac Surgery Outpatient Clinic. Results Myxoma was diagnosed in 114 cases. Malignancies were discovered in 7 cases. The left atrium was the most frequent localization. The echocardiographic image differed significantly in benign and malignant tumors. The postoperative period was complicated by embolic events or myocardial infarctions. Only malignant tumors were associated with mortality due to cardiovascular events. The survival for malignant tumors was significantly shorter. Conclusions Short and long-term results of operative treatment are very good for benign tumors in contrast to cardiac malignancies. The TTE and TEE image can be very significant in the final diagnosis. PMID:24273564

  11. 77 FR 7127 - Notice of Petitions by Firms for Determination of Eligibility To Apply for Trade Adjustment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... equipment. Wittek Golf Supply Company, Inc.. 3865 Commercial Avenue, 2/6/2012 The company manufactures golf... golf-related products such as golf balls, ball washers, course signage, club grips, and golf tees. Any...

  12. 46 CFR 160.044-3 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... free from any defects affecting serviceability. Where a choice of materials is permitted, the materials... pump size No. 3. Discharge outlets shall be provided with a tee of cast bronze or other corrosion...

  13. 46 CFR 160.044-3 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... free from any defects affecting serviceability. Where a choice of materials is permitted, the materials... pump size No. 3. Discharge outlets shall be provided with a tee of cast bronze or other corrosion...

  14. 46 CFR 160.044-3 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... free from any defects affecting serviceability. Where a choice of materials is permitted, the materials... pump size No. 3. Discharge outlets shall be provided with a tee of cast bronze or other corrosion...

  15. 78 FR 76412 - Agency Information Collection (VA National Rehabilitation Special Events, Event Registration...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-17

    ... Festival Event Application, VA0929a, b, c, d, e, f, g, h. Type of Review: Revision of an already approved... Age Games, National Veterans Creative Arts Festival, National Veterans TEE Tournament, National...

  16. The effects of Ramadan fasting on activity and energy expenditure.

    PubMed

    Lessan, Nader; Saadane, Ilham; Alkaf, Budour; Hambly, Catherine; Buckley, Adam J; Finer, Nick; Speakman, John R; Barakat, Maha T

    2018-01-01

    Fasting during the month of Ramadan entails abstinence from eating and drinking between dawn and sunset and a major shift in meal times and patterns with associated changes in several hormones and circadian rhythms; whether there are accompanying changes in energy metabolism is unclear. We have investigated the impact of Ramadan fasting on resting metabolic rate (RMR), activity, and total energy expenditure (TEE). Healthy nonobese volunteers (n = 29; 16 women) fasting during Ramadan were recruited. RMR was measured with the use of indirect calorimetry. In subgroups of participants, activity (n = 11; 5 women) and TEE (n = 10; 5 women) in free-living conditions were measured with the use of accelerometers and the doubly labeled water technique, respectively. Body composition was measured with the use of bioelectrical impedance. Measurements were repeated after a wash-out period of between 1 and 2 mo after Ramadan. Nonparametric tests were used for comparative statistics. Ramadan fasting did not result in any change in RMR (mean ± SD: 1365.7 ± 230.2 compared with 1362.9 ± 273.6 kcal/d for Ramadan and post-Ramadan respectively, P = 0.713, n = 29). However, controlling for the effects of age, sex, and body weight, RMR was higher in the first week of Ramadan than in subsequent weeks. During Ramadan, the total number of steps walked were significantly lower (n = 11, P = 0.001), while overall sleeping time was reduced and different sleeping patterns were seen. TEE did not differ significantly between Ramadan and post-Ramadan (mean ± SD: 2224.1 ± 433.7 compared with 2121.0 ± 718.5 kcal/d for Ramadan and post-Ramadan, P = 0.7695, n = 10). Ramadan fasting is associated with reduced activity and sleeping time, but no significant change in RMR or TEE. Reported weight changes with Ramadan in other studies are more likely to be due to differences in food intake. This trial is registered at clinicaltrials.gov as NCT02696421. © 2018 American Society for Nutrition. All rights

  17. Estimates of adherence and error analysis of physical activity data collected via accelerometry in a large study of free-living adults.

    PubMed

    Paul, David R; Kramer, Matthew; Stote, Kim S; Spears, Karen E; Moshfegh, Alanna J; Baer, David J; Rumpler, William V

    2008-06-09

    Activity monitors (AM) are small, electronic devices used to quantify the amount and intensity of physical activity (PA). Unfortunately, it has been demonstrated that data loss that occurs when AMs are not worn by subjects (removals during sleeping and waking hours) tend to result in biased estimates of PA and total energy expenditure (TEE). No study has reported the degree of data loss in a large study of adults, and/or the degree to which the estimates of PA and TEE are affected. Also, no study in adults has proposed a methodology to minimize the effects of AM removals. Adherence estimates were generated from a pool of 524 women and men that wore AMs for 13 - 15 consecutive days. To simulate the effect of data loss due to AM removal, a reference dataset was first compiled from a subset consisting of 35 highly adherent subjects (24 HR; minimum of 20 hrs/day for seven consecutive days). AM removals were then simulated during sleep and between one and ten waking hours using this 24 HR dataset. Differences in the mean values for PA and TEE between the 24 HR reference dataset and the different simulations were compared using paired t-tests and/or coefficients of variation. The estimated average adherence of the pool of 524 subjects was 15.8 +/- 3.4 hrs/day for approximately 11.7 +/- 2.0 days. Simulated data loss due to AM removals during sleeping hours in the 24 HR database (n = 35), resulted in biased estimates of PA (p < 0.05), but not TEE. Losing as little as one hour of data from the 24 HR dataset during waking hours results in significant biases (p < 0.0001) and variability (coefficients of variation between 7 and 21%) in the estimates of PA. Inserting a constant value for sleep and imputing estimates for missing data during waking hours significantly improved the estimates of PA. Although estimated adherence was good, measurements of PA can be improved by relatively simple imputation of missing AM data.

  18. Hours spent and energy expended in physical activity domains: Results from The Tomorrow Project cohort in Alberta, Canada

    PubMed Central

    2011-01-01

    Background Knowledge of adult activity patterns across domains of physical activity is essential for the planning of population-based strategies that will increase overall energy expenditure and reduce the risk of obesity and related chronic diseases. We describe domain-specific hours of activity and energy expended among participants in a prospective cohort in Alberta, Canada. Methods The Past Year Total Physical Activity Questionnaire was completed by 15,591 Tomorrow Project® participants, between 2001 and 2005 detailing physical activity type, duration, frequency and intensity. Domain-specific hours of activity and activity-related energy expenditure, expressed as a percent of total energy expenditure (TEE) (Mean (SD); Median (IQR)) are reported across inactive (<1.4), low active (1.4 to 1.59), active (1.6 to 1.89) and very active (≥ 1.9) Physical Activity Level (PAL = TEE:REE) categories. Results In very active women and amongst all men except those classified as inactive, activity-related energy expenditure comprised primarily occupational activity. Amongst inactive men and women in active, low active and inactive groups, activity-related energy expenditure from household activity was comparable to, or exceeded that for occupational activity. Leisure-time activity-related energy expenditure decreased with decreasing PAL categories; however, even amongst the most active men and women it accounted for less than 10 percent of TEE. When stratified by employment status, leisure-time activity-related energy expenditure was greatest for retired men [mean (SD): 10.8 (8.5) percent of TEE], compared with those who were fully employed, employed part-time or not employed. Transportation-related activity was negligible across all categories of PAL and employment status. Conclusion For the inactive portion of this population, active non-leisure activities, specifically in the transportation and occupational domains, need to be considered for inclusion in daily routines

  19. Hours spent and energy expended in physical activity domains: results from the Tomorrow Project cohort in Alberta, Canada.

    PubMed

    Csizmadi, Ilona; Lo Siou, Geraldine; Friedenreich, Christine M; Owen, Neville; Robson, Paula J

    2011-10-10

    Knowledge of adult activity patterns across domains of physical activity is essential for the planning of population-based strategies that will increase overall energy expenditure and reduce the risk of obesity and related chronic diseases. We describe domain-specific hours of activity and energy expended among participants in a prospective cohort in Alberta, Canada. The Past Year Total Physical Activity Questionnaire was completed by 15,591 Tomorrow Project® participants, between 2001 and 2005 detailing physical activity type, duration, frequency and intensity. Domain-specific hours of activity and activity-related energy expenditure, expressed as a percent of total energy expenditure (TEE) (Mean (SD); Median (IQR)) are reported across inactive (<1.4), low active (1.4 to 1.59), active (1.6 to 1.89) and very active (≥ 1.9) Physical Activity Level (PAL = TEE:REE) categories. In very active women and amongst all men except those classified as inactive, activity-related energy expenditure comprised primarily occupational activity. Amongst inactive men and women in active, low active and inactive groups, activity-related energy expenditure from household activity was comparable to, or exceeded that for occupational activity. Leisure-time activity-related energy expenditure decreased with decreasing PAL categories; however, even amongst the most active men and women it accounted for less than 10 percent of TEE. When stratified by employment status, leisure-time activity-related energy expenditure was greatest for retired men [mean (SD): 10.8 (8.5) percent of TEE], compared with those who were fully employed, employed part-time or not employed. Transportation-related activity was negligible across all categories of PAL and employment status. For the inactive portion of this population, active non-leisure activities, specifically in the transportation and occupational domains, need to be considered for inclusion in daily routines as a means of increasing population

  20. Accounting for misreporting when comparing energy intake across time in Canada.

    PubMed

    Garriguet, Didier

    2018-05-16

    Estimates of energy intake are lower in 2015 compared with 2004. The difference observed is too large to be explained by a change in energy requirements or physical activity at the population level. Self-reported dietary intake is subject to misreporting and may explain part of this difference. The objectives of this study are to assess how misreporting has changed from 2004 to 2015 and to demonstrate how these changes may affect the interpretation of the national intake data of Canadians. Data from the 2004 Canadian Community Health Survey - Nutrition (CCHS - Nutrition) and the 2015 CCHS - Nutrition were used to estimate energy intake and requirements for all participants aged 2 or older. The ratio of energy intake to total energy expenditure requirements (EI:TEE) was used to categorize respondents as under-reporters (EI:TEE ⟨ 0.70), over-reporters (EI:TEE ⟩ 1.42) or plausible reporters (EI:TEE = 0.70 to 1.42). Descriptive analyses by category of respondent were conducted for respondents aged 2 or older who participated in the measured height and weight component. The main caloric sources that contributed to the difference in estimated energy requirements were used to show the impact of misreporting on the analysis. The prevalence of under-reporters was 7.5% higher in 2015 compared with 2004, while the prevalence of over-reporters was 7.4% lower. There was no change in the prevalence of plausible reporters. Estimated energy intake from participants categorized as plausible reporters showed a difference of 84 kcal from 2004 to 2015, compared with a difference of 250 kcal for the entire sample. Estimated energy intake was lower in 2015 compared with 2004 across all categories of respondents for many foods, including sugar-sweetened beverages and milk, and was higher for only pastries and nuts. Misreporting changes will affect analysis and should, at a minimum, be acknowledged when comparing 2015 with 2004. Using a comparable category of plausible reporters or

  1. Patent foramen ovale in a large population of ischemic stroke patients: diagnosis, age distribution, gender, and race.

    PubMed

    Gupta, Vishal; Yesilbursa, Dilek; Huang, Wen Ying; Aggarwal, Kul; Gupta, Vijaya; Gomez, Camilo; Patel, Vinod; Miller, Andrew P; Nanda, Navin C

    2008-02-01

    Patent foramen ovale (PFO) is a well-recognized risk factor for ischemic strokes. The true prevalence of PFO among stroke patients is still under debate. Transesophageal echocardiography (TEE) is the "gold standard" in diagnosing PFO but the physiology requires right-to-left atrial shunting. In this report, we evaluate the prevalence of PFO in a diverse group of ischemic stroke patients studied by TEE. TEE of 1,663 ischemic stroke patients were reviewed for cardiac source of embolism, including PFO and atrial septal aneurysm (ASA). Agitated saline bubble injection was performed to look for right to left atrial shunting. Success of maneuvers to elevate right atrial pressure (RAP) was noted by looking at the atrial septal bulge. Among 1,435 ischemic stroke patients analyzed, the presence or absence of PFO could not be determined in 32.1% because bulging of the septum could not be demonstrated in patients with negative contrast study despite aggressive maneuvers to elevate RAP. Of the remaining 974 patients, 294 patients (30.2%) had a PFO. The mean age was 61.5 years in both groups, with a bimodal distribution of PFO and the highest prevalence occurring in < or =30-year-old group. Prevalence of PFO was similar in men (32.4%) and women (28.15%, P = 0.15); and in Caucasian (32.1%) and African American (27.7%; P = 0.15). ASA was present in 2.02% and hypermobile septum in 2.49% of the 1,435 patients. PFO was seen in 79.3% of the patients with ASA. Successful elevation of RAP cannot be achieved in a significant number of patients undergoing TEE and determination of PFO may be difficult. In our series, the true prevalence of PFO among ischemic stroke patients was 30.2% taking into account only those patients who showed no shunting despite bulging of the atrium septum into the left atrium (PFO absent group) during the contrast study. There was no gender or racial difference in the prevalence of PFO, but there was a bimodal distribution in prevalence with age.

  2. Daily energy expenditure, cardiorespiratory fitness and glycaemic control in people with type 1 diabetes.

    PubMed

    Valletta, John Joseph; Chipperfield, Andrew J; Clough, Geraldine F; Byrne, Christopher D

    2014-01-01

    Encouraging daily physical activity improves cardiorespiratory fitness and many cardiovascular risk factors. However, increasing physical activity often creates a challenge for people with type 1 diabetes, because of difficulties maintaining euglycemia in the face of altered food intake and adjustments to insulin doses. Our aim was to examine the triangular relationship between glucose control measured by continuous glucose monitoring system (CGMS), objective measures of total daily energy expenditure (TEE) recorded by a multi-sensory monitoring device, and cardiorespiratory fitness (CRF), in free-living subjects with type 1 diabetes. Twenty-three individuals (12 women) with type 1 diabetes who were free from micro- and macrovascular complications were recruited. TEE and glucose control were monitored simultaneously for up to 12 days, using a multi-sensory device and CGMS respectively. CRF was recorded as V02 max from a maximal treadmill test with the Bruce protocol. Subjects (mean±SD) were aged 37±11 years, with BMI = 26.5±5.1 kg.m⁻², HbA1c = 7.7±1.3% (61±14 mmol/mol) and V02 max (ml.min⁻¹.kg⁻¹)  = 39.9±8.4 (range 22.4-58.6). TEE (36.3±5.5 kcal.kg⁻¹.day⁻¹) was strongly associated with CRF(39.9±8.4 ml.min⁻¹.kg⁻¹) independently of sex (r = 0.63, p<0.01). However, neither TEE (r = -0.20, p = 0.36) nor CRF (r = -0.20, p = 0.39; adjusted for sex), were significantly associated with mean glycaemia measured by CGMS. Higher levels of energy expenditure (due to a more active lifestyle) are associated with increased cardiorespiratory fitness, but not necessarily better glycaemic control. Since increased levels of energy expenditure and good glycaemic control are both needed to protect against diabetes-related complications our data suggest they need to be achieved independently.

  3. Daily Energy Expenditure, Cardiorespiratory Fitness and Glycaemic Control in People with Type 1 Diabetes

    PubMed Central

    Valletta, John Joseph; Chipperfield, Andrew J.; Clough, Geraldine F.; Byrne, Christopher D.

    2014-01-01

    Objective Encouraging daily physical activity improves cardiorespiratory fitness and many cardiovascular risk factors. However, increasing physical activity often creates a challenge for people with type 1 diabetes, because of difficulties maintaining euglycemia in the face of altered food intake and adjustments to insulin doses. Our aim was to examine the triangular relationship between glucose control measured by continuous glucose monitoring system (CGMS), objective measures of total daily energy expenditure (TEE) recorded by a multi-sensory monitoring device, and cardiorespiratory fitness (CRF), in free-living subjects with type 1 diabetes. Research Design and Methods Twenty-three individuals (12 women) with type 1 diabetes who were free from micro- and macrovascular complications were recruited. TEE and glucose control were monitored simultaneously for up to 12 days, using a multi-sensory device and CGMS respectively. CRF was recorded as V02 max from a maximal treadmill test with the Bruce protocol. Results Subjects (mean±SD) were aged 37±11 years, with BMI = 26.5±5.1 kg.m−2, HbA1c = 7.7±1.3% (61±14 mmol/mol) and V02 max (ml.min−1.kg−1)  = 39.9±8.4 (range 22.4 – 58.6). TEE (36.3±5.5 kcal.kg−1.day−1) was strongly associated with CRF(39.9±8.4 ml.min−1.kg−1) independently of sex (r = 0.63, p<0.01). However, neither TEE (r = −0.20, p = 0.36) nor CRF (r = −0.20, p = 0.39; adjusted for sex), were significantly associated with mean glycaemia measured by CGMS. Conclusion Higher levels of energy expenditure (due to a more active lifestyle) are associated with increased cardiorespiratory fitness, but not necessarily better glycaemic control. Since increased levels of energy expenditure and good glycaemic control are both needed to protect against diabetes-related complications our data suggest they need to be achieved independently. PMID:24826899

  4. Assessment of Device-Related Thrombus and Associated Clinical Outcomes With the WATCHMAN Left Atrial Appendage Closure Device for Embolic Protection in Patients With Atrial Fibrillation (from the PROTECT-AF Trial).

    PubMed

    Main, Michael L; Fan, Dali; Reddy, Vivek Y; Holmes, David R; Gordon, Nicole T; Coggins, Tina R; House, John A; Liao, Lawrence; Rabineau, Dawn; Latus, George G; Huber, Kenneth C; Sievert, Horst; Wright, Richard F; Doshi, Shephal K; Douglas, Pamela S

    2016-04-01

    Left atrial appendage closure with the WATCHMAN device is an alternative to anticoagulation for stroke prevention in selected patients with atrial fibrillation (AF). LA device-related thrombus (DRT) is poorly defined and understood. We aimed to (1) develop consensus echocardiographic diagnostic criteria for DRT; (2) estimate the incidence of DRT; and (3) determine clinical event rates in patients with DRT. In phase 1 (training), a training manual was developed and reviewed by 3 echocardiographers with left atrial appendage closure device experience. All available transesophageal (TEE) studies in the WATCHMAN left atrial appendage system for embolic protection in patients with atrial fibrillation (PROTECT-AF) trial patients with suspected DRT were reviewed in 2 subsequent phases. In phase 2 (primary blind read), each reviewer independently scored each study for DRT, and final echo criteria were developed. Unanimously scored studies were considered adjudicated, whereas all others were reevaluated by all reviewers in phase 3 (group adjudication read). DRT was suspected in 35 of 485 patients by the site investigator, the echocardiography core laboratory, or both; 93 of the individual TEE studies were available for review. In phase 2, 3 readers agreed on 67 (72%) of time points. Based on phases 1 and 2, 5 DRT criteria were developed. In phase 3, studies without agreement in phase 2 were adjudicated using these criteria. Overall, at least 1 TEE was DRT positive in 27 (5.7%) PROTECT-AF patients. Stroke, peripheral embolism, or cardiac/unexplained death occurred in subjects with DRT at a rate of 3.4 per 100 patient-years follow-up. In conclusion, DRT were identified on at least 1 TEE in 27 PROTECT-AF patients, indicating a DRT incidence of 5.7%. Primary efficacy events in patients with DRT occurred at a rate of 3.4 per 100 patient-years follow-up, intermediate in frequency between event rates previously reported for the overall device and warfarin arms in PROTECT

  5. What Is Echocardiography?

    MedlinePlus

    ... EKG is a test that records the heart's electrical activity. A doctor or sonographer (a person specially ... this type of echo. TEE uses the same technology as transthoracic echo, but the transducer is attached ...

  6. Implementation and field evaluation of pretensioned concrete girder end crack control.

    DOT National Transportation Integrated Search

    2016-05-01

    Wisconsin bulb tee pretensioned concrete girders are currently used for bridge construction. Their efficiency in load resistance has made them particularly desirable. To provide that efficiency, these girders are heavily prestressed. Cracking is evid...

  7. 78 FR 55777 - Proposed Information Collection (VA, National Veterans Sports Programs and Special Events, Event...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... 0928j. o. National Veteran Creative Arts Festival Event Application, VA0929a, b, c, d, e, f, g, h. OMB... Creative Arts Festival, National Veterans TEE Tournament, National Disabled Veterans Winter Sports Clinic...

  8. 14 CFR Appendix D to Part 151 - Appendix D to Part 151

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...: Typical Eligible Items 1. Basic types of pavement listed as eligible under § 151.77. 2. Taxiway providing... storage hangars and/or multiple-unit tee hangars. Typical Ineligible Items 1. Basic types of pavement...

  9. 99. VIEW OF NORTHWEST SIDE OF PIER, LOOKING EAST FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    99. VIEW OF NORTHWEST SIDE OF PIER, LOOKING EAST FROM STORM-DAMAGED END. 3RD TEE BUILDINGS IN BACKGROUND - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  10. Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

    NASA Technical Reports Server (NTRS)

    Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.

    1997-01-01

    Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee

  11. Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

    NASA Technical Reports Server (NTRS)

    Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.

    1997-01-01

    Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee

  12. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis.

    PubMed

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-09-21

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. 2015 BMJ Publishing Group Ltd.

  13. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis

    PubMed Central

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-01-01

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. PMID:26392458

  14. [Anesthetic Management Using Transesophageal Echocardiography and EV1000 in a Patient with Ebstein's Anomary Undergoing Scoliosis Surgery].

    PubMed

    Tanimura, Kazuki; Miura, Yukiko; Ishii, Hisanari

    2016-02-01

    An 18-year-old female patinet with Ebstein anomaly underwent surgical repair of scoliosis under total intravenous anesthesia. In addtition to normal monitors, we used transesophageal echocardiography (TEE) and EV1000 (Edwards Lifesciences, Irvine, USA), which show stroke volume variation and stroke volume index simultaneously in a rectangular coordinates. TEE detected reversal of intracardiac shunt which caused SpO2 decrease during fixing screws at thoracic vertebrae, then manual ventilation with oxygen unproved SpO2. Because of a high venous pressure due to Ebstein anomaly, surgical bleeding seemed to be larger than usual. By using EV1000, volume status and cardiac contractility were estimated and adequate volume loading and inoptrope injection were performed to stabilize circulatory condition. The operation was completed without any cardiac and respiratory complications.

  15. Structural monitoring of Rigolets Pass Bridge.

    DOT National Transportation Integrated Search

    2009-10-01

    The overall objective of this research project was to evaluate the structural behavior of prestressed highperformance : concrete (HPC) long-span bulb-tee girders utilized in Louisiana bridge construction. To : accomplish this objective, one span of t...

  16. Beam splitter used in dual filming technique

    NASA Technical Reports Server (NTRS)

    Zeldin, S.

    1966-01-01

    Tubular tee is intersected at its junction by a reflecting/transmitting mirror angled to provide two images of an object for simultaneous photographing from two positions. This method is used when space and focal conditions are limited.

  17. Echocardiographic anatomy of the mitral valve: a critical appraisal of 2-dimensional imaging protocols with a 3-dimensional perspective.

    PubMed

    Mahmood, Feroze; Hess, Philip E; Matyal, Robina; Mackensen, G Burkhard; Wang, Angela; Qazi, Aisha; Panzica, Peter J; Lerner, Adam B; Maslow, Andrew

    2012-10-01

    To highlight the limitations of traditional 2-dimensional (2D) echocardiographic mitral valve (MV) examination methodologies, which do not account for patient-specific transesophageal echocardiographic (TEE) probe adjustments made during an actual clinical perioperative TEE examination. Institutional quality-improvement project. Tertiary care hospital. Attending anesthesiologists certified by the National Board of Echocardiography. Using the technique of multiplanar reformatting with 3-dimensional (3D) data, ambiguous 2D images of the MV were generated, which resembled standard midesophageal 2D views. Based on the 3D image, the MV scallops visualized in each 2D image were recognized exactly by the position of the scan plane. Twenty-three such 2D MV images were created in a presentation from the 3D datasets. Anesthesia staff members (n = 13) were invited to view the presentation based on the 2D images only and asked to identify the MV scallops. Their responses were scored as correct or incorrect based on the 3D image. The overall accuracy was 30.4% in identifying the MV scallops. The transcommissural view was identified correctly >90% of the time. The accuracy of the identification of A1, A3, P1, and P3 scallops was <50%. The accuracy of the identification of A2P2 scallops was ≥50%. In the absence of information on TEE probe adjustments performed to acquire a specific MV image, it is possible to misidentify the scallops. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Self-compensation in arsenic doping of CdTe

    DOE PAGES

    Ablekim, Tursun; Swain, Santosh K.; Yin, Wan -Jian; ...

    2017-07-04

    Efficient p-type doping in CdTe has remained a critical challenge for decades, limiting the performance of CdTe-based semiconductor devices. Arsenic is a promising p-type dopant; however, reproducible doping with high concentration is difficult and carrier lifetime is low. We systematically studied defect structures in As-doped CdTe using high-purity single crystal wafers to investigate the mechanisms that limit p-type doping. Two As-doped CdTe with varying acceptor density and two undoped CdTe were grown in Cd-rich and Te-rich environments. The defect structures were investigated by thermoelectric-effect spectroscopy (TEES), and first-principles calculations were used for identifying and assigning the experimentally observed defects. Measurementsmore » revealed activation of As is very low in both As-doped samples with very short lifetimes indicating strong compensation and the presence of significant carrier trapping defects. Defect studies suggest two acceptors and one donor level were introduced by As doping with activation energies at ~88 meV, ~293 meV and ~377 meV. In particular, the peak shown at ~162 K in the TEES spectra is very prominent in both As-doped samples, indicating a signature of AX-center donors. In conclusion, the AX-centers are believed to be responsible for most of the compensation because of their low formation energy and very prominent peak intensity in TEES spectra.« less

  19. Effects of Growth Hormone and Nutritional Therapy in Boys with Constitutional Growth Delay: A Randomized Controlled Trial

    PubMed Central

    Han, Joan C.; Damaso, Ligeia; Welch, Susan; Balagopal, Prabhakaran; Hossain, Jobayer; Mauras, Nelly

    2010-01-01

    Objective To examine whether supplemental nutrition augments the anabolic actions of growth hormone (GH) in boys with constitutional delay of growth and maturation (CDGM). Study design We conducted a randomized, controlled trial at an outpatient clinical research center. Subjects were 20 prepubertal boys (age 9.3±1.3y) with CDGM (height-SDS -2.0±0.5, bone age delay 1.8±0.8y, BMI-SDS -1.2±1.0, peak stimulated GH 15.7±7.7ng/mL), who were randomized (N=10/group) to 6 months observation or daily nutritional supplementation, followed by additional daily GH therapy in all for another 12 months. T-tests and repeated measures ANOVAs compared energy intake, total energy expenditure (TEE), growth, hormones and nutrition markers. Results Energy intake was increased at 6 months within the Nutrition (p=0.04) but not the Observation group, and TEE was not statistically different within either group at 6 months. Addition of 6 months GH resulted in higher energy intake and TEE in the GH/Nutrition group at 12 months (p<0.01), but not in the GH group vs. baseline. Height, weight, lean body mass, hormones and nutrition markers increased comparably in both groups throughout 18 months. Conclusions Boys with CDGM utilize energy at an accelerated rate, an imbalance not overcome with added nutrition. GH therapy increases growth comparably with or without added nutrition in these patients. PMID:20961566

  20. Energy expenditure in children with cerebral palsy and moderate / severe malnutrition during nutritional recovery.

    PubMed

    García-Contreras, Andrea A; Vásquez-Garibay, Edgar M; Romero-Velarde, Enrique; Ibarra-Gutierrez, Ana I; Troyo-Sanroman, Rogelio

    2015-05-01

    To analyze the total energy expenditure (TEE) and resting energy expenditure (REE) in children with cerebral palsy (CP) and moderate or severe malnutrition during nutritional recovery. In an intervention study, thirteen subjects with CP (10 females and 3 males with a mean age of 9y11m ± 2y3m), level V of the Gross Motor Function Classification System and moderate or severe malnutrition were included. Eight were fed by nasogastric tube and five by gastrostomy. They were compared with 57 healthy participants (31 females and 26 males with mean age of 8y7m ± 10m). Anthropometric measurements, body composition and energy expenditure by bioelectrical impedance analysis (BIA) and indirect calorimetry (IC) were performed in both groups. TEE and REE were higher in healthy children than in children with CP in kcal/d and kcal/cm/d but were lower in kcal/kg/d (p <0.001). Intensive nutritional support for four weeks in children with CP produced a significant increase in energy expenditure. TEE and REE, in children with CP, are lower than in healthy children. Estimating the REE in children with CP and malnutrition is better performed in kcal/kg/d than in kcal/cm/d. Fat-free mass (FFM) is a good predictor of the REE in healthy children and children with CP. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  1. Diagnosis and treatment of shock due to massive pulmonary embolism: approach with transesophageal echocardiography and intrapulmonary thrombolysis.

    PubMed

    Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M

    1997-11-05

    To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.

  2. Echocardiography in cardiac arrest: An emergency medicine review.

    PubMed

    Long, Brit; Alerhand, Stephen; Maliel, Kurian; Koyfman, Alex

    2018-03-01

    Cardiac arrest management primarily focuses on optimal chest compressions and early defibrillation for shockable cardiac rhythms. Non-shockable rhythms such as pulseless electrical activity (PEA) and asystole present challenges in management. Point-of-care ultrasound (POCUS) in cardiac arrest is promising. This review provides a focused assessment of POCUS in cardiac arrest, with an overview of transthoracic (TTE) and transesophageal echocardiogram (TEE), uses in arrest, and literature support. Cardiac arrest can be distinguished between shockable and non-shockable rhythms, with management varying based on the rhythm. POCUS provides a diagnostic and prognostic tool in the emergency department (ED), which may improve accuracy in clinical decision-making. Several protocols incorporate POCUS based on different cardiac views. TTE includes parasternal long axis, parasternal short axis, apical 4-chamber, and subxiphoid views, which may be used in cardiac arrest for diagnosis of underlying cause and potential prognostication. TEE is conducted by inserting the probe into the esophagus of intubated patients, with several studies evaluating its use in cardiac arrest. It is associated with few adverse effects, while allowing continued compressions (and evaluation of those compressions) and not interrupting resuscitation efforts. POCUS is a valuable diagnostic and prognostic tool in cardiac arrest, with recent literature supporting its diagnostic ability. TTE can guide resuscitation efforts dependent on the rhythm, though TTE should not interrupt other resuscitation measures. TEE can be useful during arrest, but further studies based in the ED are needed. Published by Elsevier Inc.

  3. Self-compensation in arsenic doping of CdTe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ablekim, Tursun; Swain, Santosh K.; Yin, Wan -Jian

    Efficient p-type doping in CdTe has remained a critical challenge for decades, limiting the performance of CdTe-based semiconductor devices. Arsenic is a promising p-type dopant; however, reproducible doping with high concentration is difficult and carrier lifetime is low. We systematically studied defect structures in As-doped CdTe using high-purity single crystal wafers to investigate the mechanisms that limit p-type doping. Two As-doped CdTe with varying acceptor density and two undoped CdTe were grown in Cd-rich and Te-rich environments. The defect structures were investigated by thermoelectric-effect spectroscopy (TEES), and first-principles calculations were used for identifying and assigning the experimentally observed defects. Measurementsmore » revealed activation of As is very low in both As-doped samples with very short lifetimes indicating strong compensation and the presence of significant carrier trapping defects. Defect studies suggest two acceptors and one donor level were introduced by As doping with activation energies at ~88 meV, ~293 meV and ~377 meV. In particular, the peak shown at ~162 K in the TEES spectra is very prominent in both As-doped samples, indicating a signature of AX-center donors. In conclusion, the AX-centers are believed to be responsible for most of the compensation because of their low formation energy and very prominent peak intensity in TEES spectra.« less

  4. Osteoporosis

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Osteoporosis KidsHealth / For Kids / Osteoporosis What's in this article? ... you're in your mid-20s. What Is Osteoporosis? If someone has osteoporosis (say: oss-tee-oh- ...

  5. Severe mitral regurgitation due to mitral leaflet aneurysm diagnosed by three-dimensional transesophageal echocardiography: a case report.

    PubMed

    Konishi, Takao; Funayama, Naohiro; Yamamoto, Tadashi; Hotta, Daisuke; Kikuchi, Kenjiro; Ohori, Katsumi; Nishihara, Hiroshi; Tanaka, Shinya

    2016-11-22

    A small mitral valve aneurysm (MVA) presenting as severe mitral regurgitation (MR) is uncommon. A 47-year-old man with a history of hypertension complained of exertional chest discomfort. A transthoracic echocardiogram (TTE) revealed the presence of MR and prolapse of the posterior leaflet. A 6-mm in diameter MVA, not clearly visualized by TTE, was detected on the posterior leaflet on a three-dimensional (3D) transesophageal echocardiography (TEE). The patient underwent uncomplicated triangular resection of P2 and mitral valve annuloplasty, and was discharged from postoperative rehabilitation, 2 weeks after the operation. Histopathology of the excised leaflet showed myxomatous changes without infective vegetation or signs of rheumatic heart disease. A small, isolated MVA is a cause of severe MR, which might be overlooked and, therefore, managed belatedly. 3D TEE was helpful in imaging its morphologic details.

  6. 48. VIEW OF PIER DECK, TAKEN FROM HALFWAY BETWEEN APPPROACH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. VIEW OF PIER DECK, TAKEN FROM HALFWAY BETWEEN APPPROACH AND 1ST TEE, LOOKING SOUTHWEST, SHOWING CAPTAIN'S GALLEY (LEFT) AND NEPTUNE'S LOCKER (RIGHT) - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  7. ECO-FRIENDLY GOLF TEES FILLED WITH CORN-BASED DDGS

    EPA Science Inventory

    The ethanol industry in the United States currently produces approximately 10,000,000 tons of corn processing co-products, namely distillers dried grains with solubles (DDGS). The primary use of DDGS to date has been in animal feed applications. However, there are limits to th...

  8. Maintenance of primary cell cultures of immunocytes from Cacopsylla sp. psyllids: a new in vitrio tool for the study of pest insects

    USDA-ARS?s Scientific Manuscript database

    Psyllid species are major vectors of plant pathogens, such as phytoplasmas and Liberibacter bacteria, which threaten economic stability of fruit tee crops and vegetable production worldwide. Primary cell cultures of immunocytes have been developed from the three psyllid species, Cacopsylla melanone...

  9. IFLA General Conference, 1986. Bibliographic Control Division. Section: Bibliography. Papers.

    ERIC Educational Resources Information Center

    International Federation of Library Associations and Institutions, The Hague (Netherlands).

    Papers on bibliographic control presented at the 1986 International Federation of Library Associations (IFLA) conference include: (1) "Bibliographic Interchange/Coordination in Southeast Asia (Huck Tee Lim, Malaysia); (2) "Project for 'Chinese National Bibliography' and Its Progress" (Huang Jungui, China); (3) "Subject…

  10. Glass Blowing -- Try It, You'll Like It.

    ERIC Educational Resources Information Center

    Dilavore, Philip

    1982-01-01

    Discusses the basics of scientific glassblowing, including equipment needed, lighting a hand torch (which uses a gas and oxygen mixture), and cutting tubing. Also discusses preparation of butt joints, tee joints, and bends. Photographs illustrating various techniques are provided. (JN)

  11. Prediction of energy expenditure from heart rate and accelerometry in children and adolescents using multivariate adaptive regression splines modeling

    USDA-ARS?s Scientific Manuscript database

    Free-living measurements of 24-h total energy expenditure (TEE) and activity energy expenditure (AEE) are required to better understand the metabolic, physiological, behavioral, and environmental factors affecting energy balance and contributing to the global epidemic of childhood obesity. The spec...

  12. 50 CFR Table 14a to Part 679 - Port of Landing Codes 1, Alaska

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... DUT Chefornak 189 CHF Chignik 113 CHG Cordova 115 COR Craig 116 CRG Dillingham 117 DIL Douglas 136 JNU... 168 SIT Skagway 169 SKG Soldotna 318 SOL St. George 170 STG St. Mary 319 STM St. Paul 172 STP Tee...

  13. 50 CFR Table 14a to Part 679 - Port of Landing Codes 1, Alaska

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... DUT Chefornak 189 CHF Chignik 113 CHG Cordova 115 COR Craig 116 CRG Dillingham 117 DIL Douglas 136 JNU... 168 SIT Skagway 169 SKG Soldotna 318 SOL St. George 170 STG St. Mary 319 STM St. Paul 172 STP Tee...

  14. 50 CFR Table 14a to Part 679 - Port of Landing Codes 1, Alaska

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DUT Chefornak 189 CHF Chignik 113 CHG Cordova 115 COR Craig 116 CRG Dillingham 117 DIL Douglas 136 JNU... 168 SIT Skagway 169 SKG Soldotna 318 SOL St. George 170 STG St. Mary 319 STM St. Paul 172 STP Tee...

  15. 50 CFR Table 14a to Part 679 - Port of Landing Codes 1, Alaska

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... DUT Chefornak 189 CHF Chignik 113 CHG Cordova 115 COR Craig 116 CRG Dillingham 117 DIL Douglas 136 JNU... 168 SIT Skagway 169 SKG Soldotna 318 SOL St. George 170 STG St. Mary 319 STM St. Paul 172 STP Tee...

  16. 50 CFR Table 14a to Part 679 - Port of Landing Codes 1, Alaska

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DUT Chefornak 189 CHF Chignik 113 CHG Cordova 115 COR Craig 116 CRG Dillingham 117 DIL Douglas 136 JNU... 168 SIT Skagway 169 SKG Soldotna 318 SOL St. George 170 STG St. Mary 319 STM St. Paul 172 STP Tee...

  17. 93. VIEW OF PILINGS ON SOUTHEAST SIDE, FACING NORTH FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    93. VIEW OF PILINGS ON SOUTHEAST SIDE, FACING NORTH FROM SOUTHEAST SIDE OF 4TH TEE, SHOWING RESTROOMS, PUMPHOUSE, AND THE TACKLE BOX IN BACKGROUND - Huntington Beach Municipal Pier, Pacific Coast Highway at Main Street, Huntington Beach, Orange County, CA

  18. CT based 3D printing is superior to transesophageal echocardiography for pre-procedure planning in left atrial appendage device closure.

    PubMed

    Obasare, Edinrin; Mainigi, Sumeet K; Morris, D Lynn; Slipczuk, Leandro; Goykhman, Igor; Friend, Evan; Ziccardi, Mary Rodriguez; Pressman, Gregg S

    2018-05-01

    Accurate assessment of the left atrial appendage (LAA) is important for pre-procedure planning when utilizing device closure for stroke reduction. Sizing is traditionally done with transesophageal echocardiography (TEE) but this is not always precise. Three-dimensional (3D) printing of the LAA may be more accurate. 24 patients underwent Watchman device (WD) implantation (71 ± 11 years, 42% female). All had complete 2-dimensional TEE. Fourteen also had cardiac computed tomography (CCT) with 3D printing to produce a latex model of the LAA for pre-procedure planning. Device implantation was unsuccessful in 2 cases (one with and one without a 3D model). The model correlated perfectly with implanted device size (R 2  = 1; p < 0.001), while TEE-predicted size showed inferior correlation (R 2  = 0.34; 95% CI 0.23-0.98, p = 0.03). Fisher's exact test showed the model better predicted final WD size than TEE (100 vs. 60%, p = 0.02). Use of the model was associated with reduced procedure time (70 ± 20 vs. 107 ± 53 min, p = 0.03), anesthesia time (134 ± 31 vs. 182 ± 61 min, p = 0.03), and fluoroscopy time (11 ± 4 vs. 20 ± 13 min, p = 0.02). Absence of peri-device leak was also more likely when the model was used (92 vs. 56%, p = 0.04). There were trends towards reduced trans-septal puncture to catheter removal time (50 ± 20 vs. 73 ± 36 min, p = 0.07), number of device deployments (1.3 ± 0.5 vs. 2.0 ± 1.2, p = 0.08), and number of devices used (1.3 ± 0.5 vs. 1.9 ± 0.9, p = 0.07). Patient specific models of the LAA improve precision in closure device sizing. Use of the printed model allowed rapid and intuitive location of the best landing zone for the device.

  19. Obtaining the biomechanical behavior of ascending aortic aneurysm via the use of novel speckle tracking echocardiography.

    PubMed

    Alreshidan, Mohammed; Shahmansouri, Nastaran; Chung, Jennifer; Lash, Vynka; Emmott, Alexander; Leask, Richard L; Lachapelle, Kevin

    2017-04-01

    Ex vivo measurement of ascending aortic biomechanical properties may help understand the risk for rupture or dissection of dilated ascending aortas. A validated in vivo method that can predict aortic biomechanics does not exist. Speckle tracking transesophageal echocardiography (TEE) has been used to measure ventricular stiffness; we sought to determine whether speckle TEE could be adapted to estimate aortic stiffness in vivo and compare these findings with those obtained by ex vivo tissue measurements. A total of 17 patients undergoing ascending aortic resection were recruited to with a mean aortic diameter was 56.16 ± 15 mm. Intraoperative speckle TEE tracking analysis was used to calculate aortic stiffness index using the following equation: β2=ln(SBP/DBP)/AoS, where β2 is the stiffness index; SBP is systolic blood pressure; DBP is diastolic blood pressure; and AoS is the circumferential strain. Ex vivo stiffness was obtained by mechanical tissue testing according to previously described methods. The aortic ring at the pulmonary trunk was divided into 4 equal quadrants. The in vivo stiffness index for the inner curvature, anterior wall, outer curvature, and posterior wall were 0.0544 ± 0.0490, 0.0295 ± 0.0199, 0.0411 ± 0.0328, and 0.0502 ± 0.0320, respectively. The mean ex vivo 25% apparent stiffness for inner curvature, anterior wall, outer curvature, and posterior wall were 0.0616 ± 0.0758 MPa, 0.0352 ± 0.00992 MPa, 0.0405 ± 0.0199 MPa, and 0.0327 ± 0.0106 MPa, respectively. The patient-matched ex vivo 25% apparent stiffness and in vivo stiffness index were not significantly different (P = .8617, 2-way analysis of variance with repeated measures). The use of speckle TEE appears to be a promising technique to estimate ex vivo mechanical properties of the ascending aortic tissue. Copyright © 2016 The American Association for Thoracic Surgery. All rights reserved.

  20. An application of mass spectrometry for quality control of biologicals: Highly sensitive profiling of plasma residuals in human plasma-derived immunoglobulin.

    PubMed

    Limonier, Franck; Van Steendam, Katleen; Waeterloos, Geneviève; Brusselmans, Koen; Sneyers, Myriam; Deforce, Dieter

    2017-01-30

    Thromboembolic events (TEE) associated to trace amounts of plasmatic activated coagulation factor XI (FXIa) in administrated immunoglobulin (Ig) have recently raised concerns and hence there is a need for highly sensitive profiling of residual plasma source proteins. This study aims to consider LC-ESI-QTOF data-dependent acquisition in combination with sample fractionation for this purpose. Sample fractionation proved mandatory to enable identification of plasma residuals. Two approaches were compared: Ig depletion with protein G - protein A affinity chromatography and low-abundant protein enrichment with a combinatorial peptide ligand library (ProteoMiner™, Bio-Rad). The latter allowed a higher number of identifications. Highly sensitive detection of prothrombotic FXIa was assessed with confident identification of a 1ng/mg spike. Moreover, different residuals compositions were profiled for various commercial Ig products. Using a quantitative label free analysis, a TEE-positive Ig batch was distinguished from other regular Ig products, with increased levels of FXIa but also other unique proteins. This could have prevented the recently observed TEE problems with Ig. The method is a convenient tool to better characterize Ig products after any plasma pool or manufacture process change, gaining insights in the product quality profile without any prior information required. This study characterized residual plasma proteins in Ig products, using bottom-up LC-MS/MS with conventional data-dependent acquisition, preceded by sample fractionation. Without any prior information or target-specific development, >30 proteins were identified in a commercial Ig product. Quality control relevance was demonstrated with the identification of FXIa spiked at 1ng/mg in Ig, which is below the minimal thrombotic dose of 3ng/mg observed in an in vivo model. Relative label-free quantitation highlighted significant differences in normalized abundances of residual proteins between Ig

  1. Facilitating the Furrowed Brow: An Unobtrusive Test of the Facial Feedback Hypothesis Applied to Unpleasant Affect.

    PubMed

    Larsen, Randy J; Kasimatis, Margaret; Frey, Kurt

    1992-09-01

    We examined the hypothesis that muscle contractions in the face influence subjective emotional experience. Previously, researchers have been critical of experiments designed to test this facial feedback hypothesis, particularly in terms of methodological problems that may lead to demand characteristics. In an effort to surmount these methodological problems Strack, Martin, and Stepper (1988) developed an experimental procedure whereby subjects were induced to contract facial muscles involved in the production of an emotional pattern, without being asked to actually simulate an emotion. Specifically, subjects were required to hold a pen in their teeth, which unobtrusively creates a contraction of the zygomaticus major muscles, the muscles involved in the production of a human smile. This manipulation minimises the likelihood that subjects are able to interpret their zygomaticus contractions as representing a particular emotion, thereby preventing subjects from determining the purpose of the experiment. Strack et al. (1988) found support for the facial feedback hypothesis applied to pleasant affect, in that subjects in the pen-in-teeth condition rated humorous cartoons as being funnier than subjects in the control condition (in which zygomaticus contractions were inhibited). The present study represents an extension of this nonobtrusive methodology to an investigation of the facial feedback of unpleasant affect. Consistent with the Strack et al. procedure, we wanted to have subjects furrow their brow without actually instructing them to do so and without asking them to produce any emotional facial pattern at all. This was achieved by attaching two golf tees to the subject's brow region (just above the inside comer of each eye) and then instructing them to touch the tips of the golf tees together as part of a "divided-attention" experiment. Touching the tips of the golf tees together could only be achieved by a contraction of the corrugator supercilii muscles, the

  2. Interruption of scheduled, automatic feeding and reduction of excess energy intake in toddlers.

    PubMed

    Ciampolini, Mario; Brenna, J Thomas; Giannellini, Valerio; Bini, Stefania

    2013-01-01

    Childhood obesity due to the consumption of excess calories is a severe problem in developed countries. In a previous investigation on toddlers, hospital laboratory measurements showed an association of food-demand behavior with constant lower blood glucose before meals than for scheduled meals. We hypothesize that maternal scheduling of meals for toddlers results in excess energy intake compared to feeding only on demand (previously "on request"). We tested the cross-sectional null hypothesis of no difference in energy intake between scheduled (automatic) and demanded meals (administered after evaluation) in 24 mother-toddler (21 months old at entry) pairs with chronic, nonspecific diarrhea presenting at a clinic. We tested the same hypothesis in a subset of 14 toddlers by measuring the resting (sleeping) metabolic rate 4 hours after lunch, as well as the total daily energy expenditure (TEE) in 10 toddlers. We trained mothers to recognize meal demands (as in the previous investigation) and to provide food in response, but required no blood glucose measurements before meals. Energy intake was assessed by a 10-day food diary, resting metabolic rate (RMR) by respiratory analyses (indirect calorimetry) in 14 toddlers, and TEE by doubly labeled water in 10 toddlers. Their blood parameters, anthropometry, and number of days with diarrhea were assessed before training and 50 days after training. RMR decreased from 58.6 ± 7.8 to 49.0 ± 9.1 kcal/kg/d (P < 0.001) and TEE decreased from 80.1 ± 6.9 to 67.8 ± 10.0 kcal/kg/d (P < 0.001). Energy intake decreased from 85.7 ± 15.3 to 70.3 ± 15.8 kcal/kg/d (P < 0.001). The height Z-score increased significantly, while weight growth was normal. Toddlers entering the study over the median RMR decreased their RMR significantly more than those below the median RMR (P < 0.01). Scheduled meal suspension induces meal demand frequency to increase. Demanded meals are associated with significantly lower energy intake, RMR, and TEE than

  3. Self-Reported Interview-Assisted Diet Records Underreport Energy Intake in Maintenance Hemodialysis Patients.

    PubMed

    Shapiro, Bryan B; Bross, Rachelle; Morrison, Gillian; Kalantar-Zadeh, Kamyar; Kopple, Joel D

    2015-07-01

    Studies suggest that maintenance hemodialysis (MHD) patients report dietary energy intakes (EIs) that are lower than what is actually ingested. Data supporting this conclusion have several important limitations. The present study introduces a novel approach of assessing underreporting of EI in MHD patients. Comparisons of EI of free-living MHD patients determined from food records to their measured energy needs. Metabolic research ward. Thirteen clinically stable MHD patients with unchanging weights whose EI was assessed by dietitian interview-assisted 3-day food records. EI was compared with (1) patients' resting energy expenditure (REE), measured by indirect calorimetry, and estimated total energy expenditure (TEE) and (2) patients' dietary energy requirements (DER) measured while patients underwent nitrogen balance studies and consumed a constant energy diet in a research ward for a mean duration of 89.5 days. DER was calculated as the actual EI during the research study corrected for changes in body fat and lean body mass measured by Dual X-Ray Absorptiometry. Underreporting of EI was determined by an EI:REE ratio <1.27 and an EI:TEE ratio or EI:DEE ratio <1.0. Seven of the 13 MHD patients studied were male. Patient's ages were 47.7 ± standard deviation 9.7 years; body mass index averaged 25.4 ± 2.8 kg/m2, and dialysis vintage was 53.3 ± 37.1 months. The EI:REE ratio (1.03 ± 0.23) was significantly less than the cutoff value for underreporting of 1.27 (P = .001); 12 of 13 patients had EI:REE ratios <1.27. The mean EI:TEE ratio was significantly less than the cutoff value of 1.0 (0.73 ± 0.17, P < .0001), and 12 MHD patients had EI:TEE ratios <1.0. The EI:DER ratio was also <1.0 (0.83 ± 0.25, P = .012), and 10 MHD had EI:DER ratios <1.0. Dietitian interview-assisted diet records by MHD patients substantially underestimate the patient's dietary EI. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. Alternate Welding Processes for In-Service Welding

    DOT National Transportation Integrated Search

    2009-04-24

    Conducting weld repairs and attaching hot tap tees onto pressurized pipes has the advantage of avoiding loss of service and revenue. However, the risks involved with in-service welding need to be managed by ensuring that welding is performed in a rep...

  5. Role of physical activity and sleep duration in growth and body composition of preschool-aged children

    USDA-ARS?s Scientific Manuscript database

    The impact of physical activity patterns and sleep duration on growth and body composition of preschool-aged children remains unresolved. Aims were (1) to delineate cross-sectional associations among physical activity components, sleep, total energy expenditure (TEE), and body size and composition; ...

  6. Video Golf

    NASA Technical Reports Server (NTRS)

    1995-01-01

    George Nauck of ENCORE!!! invented and markets the Advanced Range Performance (ARPM) Video Golf System for measuring the result of a golf swing. After Nauck requested their assistance, Marshall Space Flight Center scientists suggested video and image processing/computing technology, and provided leads on commercial companies that dealt with the pertinent technologies. Nauck contracted with Applied Research Inc. to develop a prototype. The system employs an elevated camera, which sits behind the tee and follows the flight of the ball down range, catching the point of impact and subsequent roll. Instant replay of the video on a PC monitor at the tee allows measurement of the carry and roll. The unit measures distance and deviation from the target line, as well as distance from the target when one is selected. The information serves as an immediate basis for making adjustments or as a record of skill level progress for golfers.

  7. McConnell's sign in intra-operative acute right ventricle ischaemia: An under-recognized aetiology.

    PubMed

    Longo, S A; Echegaray, A; Acosta, C M; Rinaldi, L I; Cabrera Schulmeyer, M C; Olavide Goya, I

    2016-11-01

    Transoesophageal echocardiography (TEE) has become a fundamental tool in modern cardiothoracic anaesthesia. It has an indisputable role in coronary valve surgery and revascularisations with severe impairment of ventricle function. It helps in making diagnoses that can optimise the surgical strategy and to minimal invasively dynamically monitor volaemia and cardiac function during the post-operative period, detecting complications unobservable by other methods. The McConnell sign, visualised using TEE as an akinesis of the right ventricular free wall, with a normal apex motility and enlargement of the right cavities, is characteristic of right ventricular (RV) dysfunction. This sign has a 77% sensitivity and 94% specificity for the diagnosis of acute pulmonary embolism (APE). The case is presented of a 53-year-old man scheduled for aortic valve and ascending aorta replacement surgery, with a history of severe valve aortic stenosis, aortic root and arch aneurysm, and with normal coronary arteries. Post-cardiopulmonary bypass (CBP), the patient presented with haemodynamic instability, with the TEE showing a typical image of the McConnell sign, with no pulmonary hypertension. This enabled making an early diagnosis of acute RV ischaemia, that led to a change in the surgical plan, the performing of coronary revascularisation surgery. As a result, the McConnell sign, which describes the characteristics of RV dysfunction, led to making a differential diagnosis between APE, RV infarction and acute myocardial ischaemia. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. The effect of phosphatidylserine on golf performance

    PubMed Central

    Jäger, Ralf; Purpura, Martin; Geiss, Kurt-Reiner; Weiß, Michael; Baumeister, Jochen; Amatulli, Francesco; Schröder, Lars; Herwegen, Holger

    2007-01-01

    Background A randomized, double-blind, placebo-controlled study was performed to evaluate the effect of oral phosphatidylserine (PS) supplementation on golf performance in healthy young golfers with handicaps of 15–40. Methods Perceived stress, heart rate and the quality of the ball flight was evaluated before (pre-test) and after (post-test) 42 days of 200 mg per day PS (n = 10) or placebo (n = 10) intake in the form of a nutritional bar. Subjects teed-off 20 times aiming at a green 135 meters from the tee area. Results PS supplementation significantly increased (p < 0.05) the number of good ball flights (mean: pre-test 8.3 ± 3.5, post-test 10.1 ± 3.0), whereas placebo intake (mean: pre-test 7.8 ± 2.4, post-test 7.9 ± 3.6) had no effect. PS supplementation showed a trend towards improving perceived stress levels during teeing-off (mean: pre-test 5.8 ± 2.0, post-test 4.0 ± 2.0, p = 0.07), whereas stress levels remained unchanged in the placebo group (mean: pre-test: 5.1 ± 2.0, post-test: 5.1 ± 3.1). Supplementation did not influence mean heart rate in either group. Conclusion It is concluded that six weeks of PS supplementation shows a statistically not significant tendency (p = 0.07) to improve perceived stress levels in golfers and significantly improves (p < 0.05) the number of good ball flights during tee-off which might result in improved golf scores. PMID:18053194

  9. Adjunctive intracardiac echocardiography imaging from the left ventricle to guide percutaneous mitral valve repair with the MitraClip in patients with failed prior surgical rings.

    PubMed

    Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott

    2016-02-01

    We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.

  10. 2D Echocardiographic Evaluation of Right Ventricular Function Correlates With 3D Volumetric Models in Cardiac Surgery Patients.

    PubMed

    Magunia, Harry; Schmid, Eckhard; Hilberath, Jan N; Häberle, Leo; Grasshoff, Christian; Schlensak, Christian; Rosenberger, Peter; Nowak-Machen, Martina

    2017-04-01

    The early diagnosis and treatment of right ventricular (RV) dysfunction are of critical importance in cardiac surgery patients and impact clinical outcome. Two-dimensional (2D) transesophageal echocardiography (TEE) can be used to evaluate RV function using surrogate parameters due to complex RV geometry. The aim of this study was to evaluate whether the commonly used visual evaluation of RV function and size using 2D TEE correlated with the calculated three-dimensional (3D) volumetric models of RV function. Retrospective study, single center, University Hospital. Seventy complete datasets were studied consisting of 2D 4-chamber view loops (2-3 beats) and the corresponding 4-chamber view 3D full-volume loop of the right ventricle. RV function and RV size of the 2D loops then were assessed retrospectively purely qualitatively individually by 4 clinician echocardiographers certified in perioperative TEE. Corresponding 3D volumetric models calculating RV ejection fraction and RV end-diastolic volumes then were established and compared with the 2D assessments. 2D assessment of RV function correlated with 3D volumetric calculations (Spearman's rho -0.5; p<0.0001). No correlation could be established between 2D estimates of RV size and actual 3D volumetric end-diastolic volumes (Spearman's rho 0.15; p = 0.25). The 2D assessment of right ventricular function based on visual estimation as frequently used in clinical practice appeared to be a reliable method of RV functional evaluation. However, 2D assessment of RV size seemed unreliable and should be used with caution. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. High incidence of echocardiographic abnormalities of the interatrial septum in patients undergoing ablation for atrial fibrillation.

    PubMed

    Schernthaner, Christiana; Danmayr, Franz; Daburger, Apollonia; Eichinger, Jörg; Hammerer, Matthias; Strohmer, Bernhard

    2013-04-01

    Atrial fibrosis or fatty deposition is known to increase the propensity for the development of atrial fibrillation (AF). Apart from the pulmonic veins, the interatrial septum (IAS) might play a role in the maintenance of AF. In contrast to left atrial anatomy and adjacent veins, the IAS cannot be visualized in detail with computed tomography. Thus, preprocedural transesophageal echocardiography (TEE) may provide important morphologic information beyond exclusion from atrial thrombi. The study comprised 108 consecutive patients (mean age 60 ± 11 years; 98 men). AF was paroxysmal in 91 (84%) and persistent in 17 (16%) patients. We investigated the morphological characteristics of the IAS by TEE in patients who underwent radiofrequency ablation of AF. The IAS was structurally abnormal in 46 (43%) patients, showing the following echocardiograhic findings: atrial septal hypermobility or aneurysm (n = 27) associated with a patent foramen ovale (PFO) (n = 11) or with a small atrial septal defect (ASD) (n = 2), a septal flap associated with a PFO or an ASD (n = 8), and an abnormally thickened IAS (n = 12). A thrombus in the left atrial appendage was discovered in only 2 (2%) patients. A structurally abnormal IAS was diagnosed in nearly half of the patients undergoing ablation therapy for AF. The information obtained by TEE is mandatory to exclude left atrial thrombi prior the ablation procedure. Moreover, detailed knowledge of morphologic characteristics of the IAS facilitates an optimized and safe performance of the transseptal puncture using long sheaths with large diameters. © 2012, Wiley Periodicals, Inc.

  12. Under-reporting of food intake is frequent among Brazilian free-living older persons: a doubly labelled water study.

    PubMed

    Ferriolli, Eduardo; Pfrimer, Karina; Moriguti, Julio C; Lima, Nereida K C; Moriguti, Eny K U; Formighieri, Paulo F; Scagliusi, Fernanda B; Marchini, Julio S

    2010-03-15

    The assessment of food intake is essential for the development of dietetic interventions. Accuracy is low when intake is assessed by questionnaires, the under-reporting of food intake being frequent. Most such studies, however, were performed in developed countries and there is little data about the older population of developing nations. This study aimed to verify the total energy expenditure (TEE) of independent older Brazilians living in an urban area, through the doubly labelled water (DLW) method and to compare it with the reported energy intake obtained through the application of a food frequency questionnaire (FFQ). Initially, 100 volunteers aged from 60 to 75 years had their body composition determined by dual-energy X-ray absorptiometry (DEXA). Five volunteers of each quartile of body fat percentage had their energy expenditure determined by DLW. The mean age of the subjects included in this phase of the study was 66.4 +/- 3.5 years, and ten of the subjects were men. The mean TEE was 2565 +/- 614 and 2154 +/- 339 kcal.day(-1) for men and women, respectively. The Physical Activity Level (PAL) was 1.58 +/- 0.31 and 1.52 +/- 0.22, respectively. Under-reporting of food intake was highly prevalent, with a mean percentage of reported intake in relation to measured TEE of -17.7%. Thus, under-reporting of food intake is highly prevalent among Brazilian independent older persons. The DLW method is an important tool in nutritional studies and its use is to be recommended in developing countries. Copyright 2010 John Wiley & Sons, Ltd.

  13. Physical activity level and physical functionality in nonagenarians compared to individuals aged 60-74 years.

    PubMed

    Frisard, Madlyn I; Fabre, Jennifer M; Russell, Ryan D; King, Christina M; DeLany, James P; Wood, Robert H; Ravussin, Eric

    2007-07-01

    Functional dependence and the risks of disability increase with age. The loss of independence is thought to be partially due to a decrease in physical activity. However, in populations, accurate measurement of physical activity is challenging and may not provide information on functional impairment. This study therefore assessed physical functionality and physical activity level in a group of nonagenarians (11 men/11 women; 93+/-1 years, 66.6+/-2.4 kg, body mass index [BMI]=24+/-1 kg/m2) and a group of participants aged 60-74 years (17 men/15 women; 70+/-1 years, 83.3+/-3.0 kg, BMI=29+/-1 kg/m2) from the Louisiana Healthy Aging Study. Physical activity level was calculated from total energy expenditure (TEE) and resting metabolic rate (RMR). Physical functionality was assessed using the Reduced Continuous Scale Physical Functional Performance Test (CS-PFP10). Nonagenarians had lower absolute (p<.001) and adjusted (p<.007) TEE compared to participants aged 60-74 years which was attributed to a reduction in both RMR and physical activity level. Nonagenarians also had reduced functional performance (p<.001) which was correlated with activity level (r=0.68, p<.001). When compared to individuals aged 60-74 years, 73% of the reduction in TEE in nonagenarians can be attributed to a reduction in physical activity level, the remaining being accounted for by a reduction in RMR. The reduced physical activity in nonagenarians is associated with less physical functionality. This study provides the first objective comparison of physical functionality and actual levels of physical activity in older individuals.

  14. Interatrial septum thickness and difficulty with transseptal puncture during redo catheter ablation of atrial fibrillation.

    PubMed

    Tomlinson, David R; Sabharwal, Nikant; Bashir, Yaver; Betts, Timothy R

    2008-12-01

    Patients undergoing catheter ablation for atrial fibrillation (AF) frequently require redo procedures, but there are no data reporting interatrial septum thickness (IAS) and difficulty during repeat transseptal puncture (TSP). Patients undergoing two separate AF ablation procedures had preprocedural fossa ovalis (FO) thickness measured using transesophageal echocardiography (TEE). "Difficult" TSP was defined by two observers as requiring excessive force, or conversion to TEE guidance. The study comprised 42 patients (37 male) with mean+/-SD age 55+/-9 years. Mean FO thickness was significantly greater at the time of redo TSP (2.2+/-1.6 mm vs 2.6+/-1.5 mm at redo, P=0.03); however, this finding was limited to those who underwent initial dual transseptal sheath procedures, FO thickness 2.0+/-1.5 mm and 2.5+/-1.4 mm for TEE 1 and 2, respectively (P=0.048). There was a trend for more frequent difficult redo TSP procedures, 7/42 (17%; 95% confidence interval [CI] 8-31) redo, versus 4/42 (10%; 95% CI 3-23) first TSP. On univariate analysis, FO thickness was not predictive of TSP difficulty; the only predictor of difficult redo TSP was diabetes. IAS thickness at the FO increased following catheter ablation of AF, yet on subgroup analysis this was limited to initial procedures utilizing dual transseptal sheaths. There was a trend toward more frequent difficulty during redo TSP, yet this was not associated with FO thickening. Diabetes may predispose to difficulty during redo TSP; this finding requires confirmation in a larger study population.

  15. Tricuspid insufficiency after laser lead extraction.

    PubMed

    Rodriguez, Yasser; Mesa, Julian; Arguelles, Eric; Carrillo, Roger G

    2013-08-01

    The use of laser lead extraction (LLE) to remove pacemaker and implantable cardiac defibrillator leads has become more prevalent in the past decade. Though the procedure is associated with a low rate of complications, LLE still poses some risks to patients. Some reports have suggested an increase in tricuspid insufficiency (TI) associated with LLE. We present a series of patients who underwent both LLE and complete evaluation for TI with echocardiographic techniques. From August 2008 to January 2010, 173 prospective, consecutive patients underwent LLE in a single center. All patients had transesophageal echocardiograms (TEE) during the extraction. Fifty-three patients had tricuspid valve function evaluated a day before the procedure with a transthoracic echocardiogram (TTE), during the procedure with a TEE and 2 days postoperatively with a TTE. All 173 patients experienced no change in tricuspid valve function during the procedure with TEE. Of the 53 patients who underwent a complete TI evaluation, 38 were males (72%) and 15 females (38%), with a mean age of 69.45 ± 14.08. Mean ejection fraction was 35.82 ± 14.72. Three (6%) patients experienced TI after the procedure (two mild and one severe, all with tricuspid valve endocarditis); 16 (30%) patients were found to have TI before LLE that returned to normal valve function during or after the procedure. Thirty-four (64%) patients did not experience any significant change of the tricuspid valve performance after LLE. LLE was not associated with increased TI. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  16. Preclinical assessment of a modified Occlutech left atrial appendage closure device in a canine model.

    PubMed

    Kim, Jung-Sun; Lee, Seul-Gee; Bong, Sung-Kyung; Park, Se-Il; Hong, Sung-Yu; Shin, Sanghoon; Shim, Chi Young; Hong, Geu-Ru; Choi, Donghoon; Jang, Yangsoo; Park, Jai-Wun

    2016-10-15

    LAA occlusion has a similar stroke prevention efficacy compared to anticoagulation treatment for non-valvular atrial fibrillation. The objective of this study was to assess the feasibility and safety of a modified Occlutech® left atrial appendage (LAA) closure device in a canine model. The device was implanted in 10 dogs (33±1kg) using fluoroscopy and transesophageal echocardiography (TEE) guidance. The modified Occlutech® LAA occlusion device was compared with the current version, the Watchman device, and the Amplazter cardiac plug (ACP). LAA occlusion and anchoring to the LAA were evaluated. All dogs were assessed using angiography, TEE, and a gross anatomy examination. The 10 LAA occlusion devices were to be implanted into 10 dogs (5 modified Occlutech devices, 3 current version of Occlutech devices, 1 Watchman, and 1 ACP). LAA implantation was not performed in one dog due to transeptal puncture failure. The three current version of Occlutech devices were embolized immediately after implantation, so three modified devices of the same size were implanted securely without embolization. The mean implant size was 20.1±2.0mm. The devices chosen were a mean of 23.3±10.6% larger than the measured landing zone diameters. Post-implant angiography and TEE revealed well-positioned devices without pericardial effusion or impingement on surrounding structures. The results of this acute animal study suggested that a modified Occlutech® LAA occlusion device was feasible and had greater anchoring performance in canines. Additional large clinical studies are needed to evaluate safety and efficacy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. 46 CFR 50.25-1 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subchapter. (b) Plate, bar stock, pipe, tube, pipe joining fittings (tees, elbows, reducers, etc.), bolting... or the cognizant Officer in Charge, Marine Inspection. (e) Components designed for hydraulic service... tested hydraulic components is granted by the Marine Safety Center or the cognizant Officer in Charge...

  18. Miniature inverted-repeat transposable element identification and genetic marker development in Agrostis

    USDA-ARS?s Scientific Manuscript database

    Creeping bentgrass (Agrostis stolonifera L.) is an important species to the turfgrass industry because of its adaptation for use in high quality turf stands such as golf course putting greens, tees, and fairways. A. stolonifera is a highly outcrossing allotetraploid making genetic marker developmen...

  19. Proceedings of the Annual Meeting of the Association for Education in Journalism and Mass Communication (83rd, Phoenix, Arizona, August 9-12, 2000). Graduate Education Interest Group.

    ERIC Educational Resources Information Center

    Association for Education in Journalism and Mass Communication.

    The Graduate Education Interest Group section of the proceedings contains the following five papers: "The Press, President, and Presidential Popularity During Ronald Reagan's War on Drugs" (Hyo-Seong Lee); "Malaysia's Broadcasting Industry in Transition: Effect of New Competitions on Traditional Television Channels" (Tee-Tuan…

  20. TCE REMOVAL FROM CONTAMINATED SOIL AND GROUND WATER

    EPA Science Inventory

    Widespread use of trichloroethylene (TEE) in the U.S. has resulted in its frequent detection in soil and groundwater. EE can become a health hazard after being processed in the human liver; or reductive dehalogenation in the environment may result in production of vinyl chloride,...

  1. Shock-absorbing caster wheel is simple and compact

    NASA Technical Reports Server (NTRS)

    Kindley, R. J.

    1968-01-01

    Compact shock-absorbing caster wheel mitigates or absorbs shock by a compressible tire which deforms into a cavity between its inner edge and the wheel hub. A tee-shaped annular ring embedded in the tire distributes loads more uniformly throughout both wheel and tire.

  2. 75 FR 8346 - Proposed CERCLA Administrative Settlement; Anderson-Calhoun Mine and Mill Site, Leadpoint, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ...-Calhoun Mine and Mill Site, Leadpoint, WA AGENCY: Environmental Protection Agency (EPA). ACTION: Notice...-Calhoun Mine and Mill Site in Leadpoint, Washington, with settling party Blue Tee Corporation. The... Anderson-Calhoun Mine and Mill Site in Leadpoint, Washington, EPA Docket No. CERCLA-10-2010-0105 and should...

  3. Managing phosphorus export from golf courses using industrial byproducts as filter materials

    USDA-ARS?s Scientific Manuscript database

    Golf courses, and in particular the tees, fairways, and putting greens, are vulnerable to loss of phosphorus (P) as dissolved reactive P (DRP) through sandy, porous grass rooting media and subsurface tile drainage. Excess levels of phosphorus (P) in surface waters promotes eutrophication, which in t...

  4. The Way Ahead for Human Terrain Teams

    DTIC Science & Technology

    2013-01-01

    achievements without ignoring shortcomings. That history can be summarized as a set of sometimes overlap- ping developmental periods. The first period...and Technology Commit- tee , U.S. House of Representatives, 110th Cong., 2nd sess., Hearings on Role of the Social and Behavioral Sciences in National

  5. European Security & Russia: A Workshop at CNAC, 13 April 2001

    DTIC Science & Technology

    2001-07-01

    Agricultural Policy , a dubious prospect. A half-hearted US commitment to Europe would be another ingredi- ent for continued drift. US withdrawal might... Agricultural Policy , had the responsibility for guaran- teeing European security throughout the Cold War. The prospective members ofboth NATO and the EU in

  6. Revision of dietary reference intakes for energy in preschool-age children

    USDA-ARS?s Scientific Manuscript database

    Dietary Reference Intakes (DRI) for energy aim to balance energy expenditure at a level of physical activity consistent with health and support adequate growth in children. DRIs were derived from total energy expenditure (TEE) measured by using the doubly labeled water (DLW) method; however, the dat...

  7. A matter of life and death: population mortality and football results

    PubMed Central

    Kirkup, W; Merrick, D

    2003-01-01

    Objectives: To determine whether football results are associated with mortality from circulatory disease. Design: Retrospective study, comparing mortality on days of football matches between 18 August 1994 and 28 December 1999 with the results of the football matches. Setting: Newcastle and North Tyneside, Sunderland, Tees, and Leeds Health Authority areas of England. Subjects: All persons resident in Newcastle and North Tyneside, Sunderland, Tees, and Leeds Health Authority areas of England. Main outcome measures: Mortality attributable to acute myocardial infarction and stroke. Results: On days when the local professional football team lost at home, mortality attributable to acute myocardial infarction and stroke increased significantly in men (relative risk 1.28, 95% confidence intervals 1.11 to 1.47). No increase was observed in women. Conclusions: Results achieved by the local professional football team are associated systematically with circulatory disease death rates over a five year period in men, but not women. PMID:12775788

  8. Learning without labeling: domain adaptation for ultrasound transducer localization.

    PubMed

    Heimann, Tobias; Mountney, Peter; John, Matthias; Ionasec, Razvan

    2013-01-01

    The fusion of image data from trans-esophageal echography (TEE) and X-ray fluoroscopy is attracting increasing interest in minimally-invasive treatment of structural heart disease. In order to calculate the needed transform between both imaging systems, we employ a discriminative learning based approach to localize the TEE transducer in X-ray images. Instead of time-consuming manual labeling, we generate the required training data automatically from a single volumetric image of the transducer. In order to adapt this system to real X-ray data, we use unlabeled fluoroscopy images to estimate differences in feature space density and correct covariate shift by instance weighting. An evaluation on more than 1900 images reveals that our approach reduces detection failures by 95% compared to cross validation on the test set and improves the localization error from 1.5 to 0.8 mm. Due to the automatic generation of training data, the proposed system is highly flexible and can be adapted to any medical device with minimal efforts.

  9. Analytical and experimental studies of flow-induced vibration of SSME components

    NASA Technical Reports Server (NTRS)

    Chen, S. S.; Jendrzejczyk, J. A.; Wambsganss, M. W.

    1987-01-01

    Components of the Space Shuttle Main Engines (SSMEs) are subjected to a severe environment that includes high-temperature, high-velocity flows. Such flows represent a source of energy that can induce and sustain large-amplitude vibratory stresses and/or result in fluidelastic instabilities. Three components are already known to have experienced failures in evaluation tests as a result of flow-induced structural motion. These components include the liquid-oxygen (LOX) posts, the fuel turbine bellows shield, and the internal inlet tee splitter vane. Researchers considered the dynamic behavior of each of these components with varying degrees of effort: (1) a theoretical and experimental study of LOX post vibration excited by a fluid flow; (2) an assessment of the internal inlet tee splitter vane vibration (referred to as the 4000-Hz vibration problem); and (3) a preliminary consideration of the bellows shield problem. Efforts to resolve flow-induced vibration problems associated with the SSMEs are summarized.

  10. Hidden Transcripts of Teacher Resistance: A Case from South Korea

    ERIC Educational Resources Information Center

    Choi, Tae-Hee

    2017-01-01

    This paper explores teachers' resistance against pedagogic reform in South Korea, which was instituted in the form of an in-service teacher certification. Ideas for the reform, Teaching English in English (TEE), were borrowed from "native-English-speaking countries" and implemented without systematic localization, therefore, it was not…

  11. 77 FR 63270 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-16

    ... missing fastener between certain stringers of the fuselage frame which connects the frame to a tee. This proposed AD would require a rototest inspection and modification or repair of the fuselage frame at the... Portal: Go to http://www.regulations.gov . Follow the instructions for submitting comments. Fax: (202...

  12. Long-term Effects of Two Levels of Caloric Restriction on Body Composition, and Diet Satisfaction in CALERIE, a One Year Randomized Controlled Trial

    USDA-ARS?s Scientific Manuscript database

    There is little information on whether the extent of dietary energy restriction in a weight loss program influences long-term weight change. We examined the effects of two levels of caloric restriction (CR) over 12 months on body weight and fat loss, total energy expenditure (TEE), resting metabolic...

  13. Tricuspid annulus: A spatial and temporal analysis

    PubMed Central

    Knio, Ziyad O.; Montealegre-Gallegos, Mario; Yeh, Lu; Chaudary, Bilal; Jeganathan, Jelliffe; Matyal, Robina; Khabbaz, Kamal R.; Liu, David C.; Senthilnathan, Venkatachalam; Mahmood, Feroze

    2016-01-01

    Background: Traditional two-dimensional (2D) echocardiographic evaluation of tricuspid annulus (TA) dilation is based on single-frame measurements of the septolateral (S-L) dimension. This may not represent either the axis or the extent of dynamism through the entire cardiac cycle. In this study, we used real-time 3D transesophageal echocardiography (TEE) to analyze geometric changes in multiple axes of the TA throughout the cardiac cycle in patients without right ventricular abnormalities. Materials and Methods: R-wave-gated 3D TEE images of the TA were acquired in 39 patients undergoing cardiovascular surgery. The patients with abnormal right ventricular/tricuspid structure or function were excluded from the study. For each patient, eight points along the TA were traced in the 3D dataset and used to reconstruct the TA at four stages of the cardiac cycle (end- and mid-systole, end- and mid-diastole). Statistical analyses were applied to determine whether TA area, perimeter, axes, and planarity changed significantly over each stage of the cardiac cycle. Results: TA area (P = 0.012) and perimeter (P = 0.024) both changed significantly over the cardiac cycle. Of all the axes, only the posterolateral-anteroseptal demonstrated significant dynamism (P < 0.001). There was also a significant displacement in the vertical axis between the points and the regression plane in end-systole (P < 0.001), mid-diastole (P = 0.014), and mid-systole (P < 0.001). Conclusions: The TA demonstrates selective dynamism over the cardiac cycle, and its axis of maximal dynamism is different from the axis (S-L) that is routinely measured with 2D TEE. PMID:27716689

  14. Energy expenditure evaluation in humans and non-human primates by SenseWear Armband. Validation of energy expenditure evaluation by SenseWear Armband by direct comparison with indirect calorimetry.

    PubMed

    Casiraghi, Francesca; Lertwattanarak, Raweewan; Luzi, Livio; Chavez, Alberto O; Davalli, Alberto M; Naegelin, Terry; Comuzzie, Anthony G; Frost, Patricia; Musi, Nicolas; Folli, Franco

    2013-01-01

    The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard", IC, in humans.

  15. Energy Requirement Assessment and Water Turnover in Japanese College Wrestlers Using the Doubly Labeled Water Method.

    PubMed

    Sagayama, Hiroyuki; Kondo, Emi; Shiose, Keisuke; Yamada, Yosuke; Motonaga, Keiko; Ouchi, Shiori; Kamei, Akiko; Osawa, Takuya; Nakajima, Kohei; Takahashi, Hideyuki; Higaki, Yasuki; Tanaka, Hiroaki

    2017-01-01

    Estimated energy requirements (EERs) are important for sports based on body weight classifications to aid in weight management. The basis for establishing EERs varies and includes self-reported energy intake (EI), predicted energy expenditure, and measured daily energy expenditure. Currently, however, no studies have been performed with male wrestlers using the highly accurate and precise doubly labeled water (DLW) method to estimate energy and fluid requirement. The primary aim of this study was to compare total energy expenditure (TEE), self-reported EI, and the difference in collegiate wrestlers during a normal training period using the DLW method. The secondary aims were to measure the water turnover and the physical activity level (PAL) of the athletes, and to examine the accuracy of two currently used equations to predict EER. Ten healthy males (age, 20.4±0.5 y) belonging to the East-Japan college league participated in this study. TEE was measured using the DLW method, and EI was assessed with self-reported dietary records for ~1 wk. There was a significant difference between TEE (17.9±2.5 MJ•d -1 [4,283±590 kcal•d -1 ]) and self-reported EI (14.4±3.3 MJ•d -1 [3,446±799 kcal•d -1 ]), a difference of 19%. The water turnover was 4.61±0.73 L•d -1 . The measured PAL (2.6±0.3) was higher than two predicted values during the training season and thus the two EER prediction equations produced underestimated values relative to DLW. We found that previous EERs were underestimating requirements in collegiate wrestlers and that those estimates should be revised.

  16. Echocardiography-based hemodynamic management of left ventricular diastolic dysfunction: a feasibility and safety study.

    PubMed

    Shillcutt, Sasha K; Montzingo, Candice R; Agrawal, Ankit; Khaleel, Maseeha S; Therrien, Stacey L; Thomas, Walker R; Porter, Thomas R; Brakke, Tara R

    2014-11-01

    Patients with left ventricular diastolic dysfunction (LVDD) are at increased risk of postoperative adverse events. The primary aim of this study was to evaluate the safety and feasibility of using echocardiography-guided hemodynamic management (EGHEM) during surgery in subjects with LVDD compared to conventional management. The feasibility of using echocardiography to direct a treatment algorithm and clinical outcomes were compared for safety between groups. Subjects were screened for LVDD by preoperative transthoracic echocardiography (TTE) and randomized to the conventional or EGHEM group. Subjects in EGHEM received hemodynamic management based on left ventricular filling patterns on transesophageal echocardiography (TEE). Primary outcomes measured were the feasibility to obtain TEE images and follow a TEE-based treatment algorithm. Safety outcomes also compared the following clinical differences between groups: length of hospitalization, incidence of atrial fibrillation, congestive heart failure (CHF), myocardial infarction, cerebrovascular accident, transient ischemic attack and renal failure measured 30 days postoperatively. Population consisted of 28 surgical subjects (14 in conventional group and 14 in EGHEM group). Mean subject age was 73.4 ± 6.7 years (36% male) in conventional group and 65.9 ± 14.4 years (36% male) in EGHEM group. Procedures included orthopedic (conventional = 29%, EGHEM 36%), general (conventional = 50%, EGHEM = 36%), vascular (conventional = 7%, EGHEM = 21%), and thoracic (conventional = 14%, EGHEM = 7%). There was no statistically significant difference in adverse clinical events between the 2 groups. The EGHEM group had less CHF, atrial fibrillation, and shorter length of stay. Echocardiography-guided hemodynamic management of patients with LVDD during surgery is feasible and may be a safe alternative to conventional management. © 2014, Wiley Periodicals, Inc.

  17. Infective endocarditis in the transesophageal echocardiographic era.

    PubMed

    Hwang, J J; Shyu, K G; Chen, J J; Ko, Y L; Lin, J L; Tseng, Y Z; Kuan, P; Lien, W P

    1993-01-01

    During a 45-month period, 50 consecutive patients with infective endocarditis were evaluated at the National Taiwan University Hospital with emphasis on the role of transesophageal echocardiography (TEE) in the management of these patients. Among them, rheumatic heart disease was still the most common underlying cardiac disorder (10/50, 20%), while mitral valve prolapse (8/50, 16%) and congenital heart disease (8/50, 16%) were also frequently encountered. More than one third (19/50, 38%) had no underlying heart disease. Four intravenous drug abusers, quite rare previously in Taiwan, were found during the study period. Native valves involved were mostly mitral valve (n = 18), aortic valve (n = 15), and both mitral and aortic valves (n = 3). Tricuspid valve and pulmonic valve were involved in 3 and 2 patients, respectively. Streptococcus viridans was the leading microorganism isolated (21/50, 42%). Staphylococci and enterococci were found in 9 (18%) and 5 (10%) patients, respectively. Twelve patients (24%) were culture-negative in this series. Embolic complications occurred in 13 patients (26%), with a total of 17 episodes. No significant correlation was found between the occurrence of embolization and the vegetation size or the location of the vegetation, if patients with right-sided valvular vegetation and no identifiable vegetation were excluded. Surgery was needed by 25 patients (50%), and mortality occurred in 6 (12%). TEE was superior to transthoracic echocardiography in the detection of vegetations at the mitral or prosthetic valves. Concerning the associated complications with infective endocarditis, TEE was also superior in estimating the severity of mitral regurgitation, recognizing ruptured chordae tendineae and detecting subaortic complications such as valve ring abscess and mitral valve perforation.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Dilution space ratio of 2H and 18O of doubly labeled water method in humans.

    PubMed

    Sagayama, Hiroyuki; Yamada, Yosuke; Racine, Natalie M; Shriver, Timothy C; Schoeller, Dale A

    2016-06-01

    Variation of the dilution space ratio (Nd/No) between deuterium ((2)H) and oxygen-18 ((18)O) impacts the calculation of total energy expenditure (TEE) by doubly labeled water (DLW). Our aim was to examine the physiological and methodological sources of variation of Nd/No in humans. We analyzed data from 2,297 humans (0.25-89 yr old). This included the variables Nd/No, total body water, TEE, body mass index (BMI), and percent body fat (%fat). To differentiate between physiologic and methodologic sources of variation, the urine samples from 54 subjects were divided and blinded and analyzed separately, and repeated DLW dosing was performed in an additional 55 participants after 6 mo. Sex, BMI, and %fat did not significantly affect Nd/No, for which the interindividual SD was 0.017. The measurement error from the duplicate urine sample sets was 0.010, and intraindividual SD of Nd/No in repeats experiments was 0.013. An additional SD of 0.008 was contributed by calibration of the DLW dose water. The variation of measured Nd/No in humans was distributed within a small range and measurement error accounted for 68% of this variation. There was no evidence that Nd/No differed with respect to sex, BMI, and age between 1 and 80 yr, and thus use of a constant value is suggested to minimize the effect of stable isotope analysis error on calculation of TEE in the DLW studies in humans. Based on a review of 103 publications, the average dilution space ratio is 1.036 for individuals between 1 and 80 yr of age. Copyright © 2016 the American Physiological Society.

  19. The validity of a web-based FFQ assessed by doubly labelled water and multiple 24-h recalls.

    PubMed

    Medin, Anine C; Carlsen, Monica H; Hambly, Catherine; Speakman, John R; Strohmaier, Susanne; Andersen, Lene F

    2017-12-01

    The aim of this study was to validate the estimated habitual dietary intake from a newly developed web-based FFQ (WebFFQ), for use in an adult population in Norway. In total, ninety-two individuals were recruited. Total energy expenditure (TEE) measured by doubly labelled water was used as the reference method for energy intake (EI) in a subsample of twenty-nine women, and multiple 24-h recalls (24HR) were used as the reference method for the relative validation of macronutrients and food groups in the entire sample. Absolute differences, ratios, crude and deattenuated correlations, cross-classifications, Bland-Altman plot and plots between misreporting of EI (EI-TEE) and the relative misreporting of food groups (WebFFQ-24HR) were used to assess the validity. Results showed that EI on group level was not significantly different from TEE measured by doubly labelled water (0·7 MJ/d), but ranking abilities were poor (r -0·18). The relative validation showed an overestimation for the majority of the variables using absolute intakes, especially for the food groups 'vegetables' and 'fish and shellfish', but an improved agreement between the test and reference tool was observed for energy adjusted intakes. Deattenuated correlation coefficients were between 0·22 and 0·89, and low levels of grossly misclassified individuals (0-3 %) were observed for the majority of the energy adjusted variables for macronutrients and food groups. In conclusion, energy estimates from the WebFFQ should be used with caution, but the estimated absolute intakes on group level and ranking abilities seem acceptable for macronutrients and most food groups.

  20. Advocacy for Art Education: Beyond Tee-Shirts and Bumper Stickers

    ERIC Educational Resources Information Center

    Bobick, Bryna; DiCindio, Carissa

    2012-01-01

    Advocacy is not new to art education. Over the years, Goldfarb (1979), Hodsoll (1985), and Erickson and Young (1996) have written about the importance of arts advocacy, but the concept of advocacy has evolved with the times. For example, in the 1970s, arts advocacy was described as a "movement" and brought together art educators,…

  1. Benefits and Constraints of Distributed Cognition in Foreign Language Learning: Creating a Web-Based Tourist Guide for London

    ERIC Educational Resources Information Center

    Narciss, Susanne; Koerndle, Hermann

    2008-01-01

    This paper uses the framework of distributed cognition to discuss benefits and constraints of technology adoption and use in social-constructive language learning scenarios. The purposes of this paper are (a) to describe how the open-ended knowledge construction and communication tools TEE (The Electronic Exercise) and EF-editor (Exercise Format…

  2. Brain-Building Math Games.

    ERIC Educational Resources Information Center

    Jung, Loretta Welk

    1983-01-01

    Index cards, masking tape, pizza shells, golf tees, and empty soda bottles can be used to make manipulative objects to be used in children's mathematics games. Twenty-two games that provide practice in number drills and problem solving are described, along with instructions for making objects needed for the games. (PP)

  3. Analyzing the Cohesion of English Text and Discourse with Automated Computer Tools

    ERIC Educational Resources Information Center

    Jeon, Moongee

    2014-01-01

    This article investigates the lexical and discourse features of English text and discourse with automated computer technologies. Specifically, this article examines the cohesion of English text and discourse with automated computer tools, Coh-Metrix and TEES. Coh-Metrix is a text analysis computer tool that can analyze English text and discourse…

  4. 76 FR 25704 - Announcement of Funding Awards for the Emergency Capital Repair Grant Program; Fiscal Year 2010

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    .......... PA 12 251,953 Replace windows, emergency call system, elevators and roof. Culpepper Garden I Culpepper Garden I, Inc. Arlington VA 204 447,071 Replace the convertor system tees and piping. DePaul House............ NC 75 272,210 Replace the roofs and correct the failed drainage system. Highlands Manor National...

  5. 78 FR 26756 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-08

    ... in to a golf course or online when a tee-time is scheduled online. There are no forms that have been... daily business transactions difficult at the golf courses. Affected Public: Individuals or households... Collection Respondents are golf patrons who provide business to the Air Force Golf Courses. The information...

  6. Improving Teacher-Made Assessments in Technology and Engineering Education

    ERIC Educational Resources Information Center

    White, Jesse W.; Moye, Johnny J.; Gareis, Christopher R.; Hylton, Sarah P.

    2018-01-01

    In the interest of learning how to effectively use the technological literacy standards and of adhering to education regulation, this article focuses on efforts to improve the professional teaching practices of Technology and Engineering Education (TEE) teachers by using the Gareis and Grant (2015) process with respect to "Standards for…

  7. Infant-Directed Speech Supports Phonetic Category Learning in English and Japanese

    ERIC Educational Resources Information Center

    Werker, Janet F.; Pons, Ferran; Dietrich, Christiane; Kajikawa, Sachiyo; Fais, Laurel; Amano, Shigeaki

    2007-01-01

    Across the first year of life, infants show decreased sensitivity to phonetic differences not used in the native language [Werker, J. F., & Tees, R. C. (1984). Cross-language speech perception: evidence for perceptual reorganization during the first year of life. "Infant Behaviour and Development," 7, 49-63]. In an artificial language learning…

  8. Asia Section. Regional Activities Division. Paper.

    ERIC Educational Resources Information Center

    International Federation of Library Associations, The Hague (Netherlands).

    Two papers on library and information activities in developing nations, particularly in India and other Asian countries, were presented at the 1983 International Federation of Library Associations (IFLA) conference. In "IFLA in Asia: A Review of the Work of the Regional Section for Asia," Edward Lim Huck Tee (Malaysia) describes the low…

  9. High Power High Efficiency Ka-Band Power Combiners for Solid-State Devices

    NASA Technical Reports Server (NTRS)

    Freeman, Jon C.; Wintucky, Edwin G.; Chevalier, Christine T.

    2006-01-01

    Wide-band power combining units for Ka-band are simulated for use as MMIC amplifier applications. Short-slot couplers as well as magic-tees are the basic elements for the combiners. Wide bandwidth (5 GHz) and low insertion (approx.0.2 dB) and high combining efficiencies (approx.90 percent) are obtained.

  10. JPRS Report Soviet Union Political Affairs.

    DTIC Science & Technology

    1990-06-27

    introduction of the death penalty has not solved this problem; crimes are on the increase. The great fourth-century teacher St. Basil ofCappadocia stated...tee’s specialists is the confirmation of this. It seems that the publication of data on morbidity and human health related to the use of pesticides

  11. A Comparison of Selected Kinematic Factors in Male Baseball and Female Fast Pitch Softball Batting.

    ERIC Educational Resources Information Center

    Spragg, Carolyn; Noble, Larry

    Six female intercollegiate varsity softball players and six male intercollegiate varsity baseball players were filmed from overhead while batting a wiffle ball off a batting tee at hip height. Movements of the hips, trunk, upper body segments, and bat were analyzed. Group comparisons indicated that males had higher peak linear and, angular…

  12. High-Value Care in the Evaluation of Stroke.

    PubMed

    Urja, Prakrity; Nippoldt, Eric H; Barak, Virginia; Valenta, Carrie

    2017-08-01

    Value-based care emphasizes achieving the greatest overall health benefit for every dollar spent. We present an interesting case of stroke, which made us consider how frequently health care providers are utilizing value-based care. A 73-year-old Caucasian, who was initially admitted for a hypertensive emergency, was transferred to our facility for worsening slurring of speech and left-sided weakness. The patient had an extensive chronic cerebrovascular disease, including multiple embolic type strokes, mainly in the distribution of the right temporal-occipital cerebral artery and transient ischemic attacks (TIAs). The patient had a known history of patent foramen ovale (PFO) and occlusion of the right internal carotid artery. He was complicated by intracranial hemorrhage while on anticoagulation for pulmonary embolism. He was chronically on dual antiplatelet therapy (aspirin and clopidogrel) and statin.  Following the transfer, stroke protocol, including the activation of the stroke team, a computed tomography (CT) imaging study, and the rapid stabilization of the patient was initiated. His vitals were stable, and the physical examination was significant for the drooping of the left angle of the mouth, a nonreactive right pupil consistent with the previous stroke, a decreased strength in the left upper and lower extremities, and a faint systolic murmur. His previous stroke was shown to be embolic, involving both the right temporal and occipital regions, which was re-demonstrated in a CT scan. A magnetic resonance imaging (MRI) scan of the brain showed a new, restricted diffusion in the right pons that was compatible with an acute stroke as well as diffusely atherosclerotic vessels with a focal stenosis of the branch vessels. A transthoracic echocardiogram demonstrated no new thrombus in the heart. A transesophageal echocardiogram (TEE) showed known PFO, and repeat hypercoagulation evaluation was negative, as it was in his previous cerebrovascular accident (CVA

  13. Diet misreporting can be corrected: confirmation of the association between energy intake and fat-free mass in adolescents.

    PubMed

    Vainik, Uku; Konstabel, Kenn; Lätt, Evelin; Mäestu, Jarek; Purge, Priit; Jürimäe, Jaak

    2016-10-01

    Subjective energy intake (sEI) is often misreported, providing unreliable estimates of energy consumed. Therefore, relating sEI data to health outcomes is difficult. Recently, Börnhorst et al. compared various methods to correct sEI-based energy intake estimates. They criticised approaches that categorise participants as under-reporters, plausible reporters and over-reporters based on the sEI:total energy expenditure (TEE) ratio, and thereafter use these categories as statistical covariates or exclusion criteria. Instead, they recommended using external predictors of sEI misreporting as statistical covariates. We sought to confirm and extend these findings. Using a sample of 190 adolescent boys (mean age=14), we demonstrated that dual-energy X-ray absorptiometry-measured fat-free mass is strongly associated with objective energy intake data (onsite weighted breakfast), but the association with sEI (previous 3-d dietary interview) is weak. Comparing sEI with TEE revealed that sEI was mostly under-reported (74 %). Interestingly, statistically controlling for dietary reporting groups or restricting samples to plausible reporters created a stronger-than-expected association between fat-free mass and sEI. However, the association was an artifact caused by selection bias - that is, data re-sampling and simulations showed that these methods overestimated the effect size because fat-free mass was related to sEI both directly and indirectly via TEE. A more realistic association between sEI and fat-free mass was obtained when the model included common predictors of misreporting (e.g. BMI, restraint). To conclude, restricting sEI data only to plausible reporters can cause selection bias and inflated associations in later analyses. Therefore, we further support statistically correcting sEI data in nutritional analyses. The script for running simulations is provided.

  14. Multiline 3D beamforming using micro-beamformed datasets for pediatric transesophageal echocardiography

    NASA Astrophysics Data System (ADS)

    Bera, D.; Raghunathan, S. B.; Chen, C.; Chen, Z.; Pertijs, M. A. P.; Verweij, M. D.; Daeichin, V.; Vos, H. J.; van der Steen, A. F. W.; de Jong, N.; Bosch, J. G.

    2018-04-01

    Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently developed a prototype miniaturized matrix transducer for pediatric patients with micro-beamforming and a small central transmitter. In this paper we propose two multiline parallel 3D beamforming techniques (µBF25 and µBF169) using the micro-beamformed datasets from 25 and 169 transmit events to achieve volume rates of 300 Hz and 44 Hz, respectively. Both the realizations use angle-weighted combination of the neighboring overlapping sub-volumes to avoid artifacts due to sharp intensity changes introduced by parallel beamforming. In simulation, the image quality in terms of the width of the point spread function (PSF), lateral shift invariance and mean clutter level for volumes produced by µBF25 and µBF169 are similar to the idealized beamforming using a conventional single-line acquisition with a fully-sampled matrix transducer (FS4k, 4225 transmit events). For completeness, we also investigated a 9 transmit-scheme (3  ×  3) that allows even higher frame rates but found worse B-mode image quality with our probe. The simulations were experimentally verified by acquiring the µBF datasets from the prototype using a Verasonics V1 research ultrasound system. For both µBF169 and µBF25, the experimental PSFs were similar to the simulated PSFs, but in the experimental PSFs, the clutter level was ~10 dB higher. Results indicate that the proposed multiline 3D beamforming techniques with the prototype matrix transducer are promising candidates for real-time pediatric 3D TEE.

  15. Hemodynamic and respiratory factors that influence the opening of patent foramen ovale in mechanically ventilated patients.

    PubMed

    Vavlitou, A; Minas, G; Zannetos, S; Kyprianou, T; Tsagourias, M; Matamis, D

    2016-01-01

    Patent foramen ovale (PFO) is an anatomic variant that may lead to several pathological conditions, notably right to left shunt, paradoxical embolism, hypoxemia, and cerebral fat embolism. Mechanical positive pressure ventilation may increase the prevalence of PFO opening in Intensive Care Unit (ICU) patients; however, the respiratory and hemodynamic determinants of PFO opening have been poorly investigated. Contrast-enhanced transesophageal echocardiogram (ce-TEE) is considered the gold standard for PFO detection. We prospectively performed a multicenter study using ce-TEE in order to determine the respiratory and hemodynamic factors that may lead to PFO opening. One hundred and eight consecutive ICU adult patients under mechanical ventilation from three tertiary care hospitals, were included in the study. A standard multiplane ce-TEE was performed, and the dimensions and function of the right and left ventricle were studied. In each patient, the right ventricle (RV) end-diastolic area, RV end-systolic area, left ventricle (LV) end-diastolic area, and LV ejection fraction were measured using the modified Simpson's rule and the four-chamber view. At least three bubble tests were performed to detect PFO opening. Ventilatory parameters such as tidal volume, plateau pressure, static lung compliance, and positive end-expiratory pressure were recorded during the bubble test. Data for 81 men and 27 women were analyzed. PFO was detected in 27 % of the study population. Statistical significance was found between the presence of PFO and plateau pressure (odds ratio 3.421, 95 % CI: 1.2-9.4, p =0.017). Additionally, the presence of right ventricular dilatation (RV>LV) was strongly associated with PFO opening (odds ratio 3.163, 95 % CI: 1.2-8.075, p =0.018). In this group of mechanically ventilated, critically ill adult patients, right ventricular dilatation and plateau pressure above 26 mmHg were significantly associated with foramen ovale opening. Hippokratia 2016, 20

  16. Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

    PubMed Central

    Casiraghi, Francesca; Chavez, Alberto O.; Davalli, Alberto M.; Naegelin, Terry; Comuzzie, Anthony G.; Frost, Patricia; Musi, Nicolas; Folli, Franco

    2013-01-01

    Introduction The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. Methods We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. Results In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. Conclusion SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with “gold standard”, IC, in humans. PMID:24069218

  17. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study.

    PubMed

    Kim, Yun Gi; Choi, Jong-Il; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796-2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726-16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation.

  18. Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial.

    PubMed

    Boersma, Lucas V; Ince, Hueseyin; Kische, Stephan; Pokushalov, Evgeny; Schmitz, Thomas; Schmidt, Boris; Gori, Tommaso; Meincke, Felix; Protopopov, Alexey Vladimir; Betts, Timothy; Foley, David; Sievert, Horst; Mazzone, Patrizio; De Potter, Tom; Vireca, Elisa; Stein, Kenneth; Bergmann, Martin W

    2017-09-01

    Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry. A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice. The baseline CHA 2 DS 2 -VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related. LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Ultrasound confirmation of central venous catheter position via a right supraclavicular fossa view using a microconvex probe: an observational pilot study.

    PubMed

    Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan

    2015-01-01

    Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.

  20. Low Rates of Major Complications for Radiofrequency Ablation of Atrial Fibrillation Maintained Over 14 Years: A Single Centre Experience of 2750 Consecutive Cases.

    PubMed

    Voskoboinik, Aleksandr; Sparks, Paul B; Morton, Joseph B; Lee, Geoffrey; Joseph, Stephen A; Hawson, Joshua J; Kistler, Peter M; Kalman, Jonathan M

    2018-02-03

    Despite technological advances, studies continue to report high complication rates for atrial fibrillation (AF) ablation. We sought to review complication rates for AF ablation at a high-volume centre over a 14-year period and identify predictors of complications. We reviewed prospectively collected data from 2750 consecutive AF ablation procedures at our institution using radiofrequency energy (RF) between January 2004 and May 2017. All cases were performed under general anaesthetic with transoesophageal echocardiography (TEE), 3D-mapping and an irrigated ablation catheter. Double transseptal puncture was performed under TEE guidance. All patients underwent wide antral circumferential isolation of the pulmonary veins (30W anteriorly, 25W posteriorly) with substrate modification at operator discretion. Of 2255 initial and 495 redo procedures, ablation strategies were: pulmonary vein isolation (PVI) only 2097 (76.3%), PVI+lines 368 (13.4%), PVI+posterior wall 191 (6.9%), PVI+cavotricuspid isthmus 277 (10.1%). There were 23 major (0.84%) and 20 minor (0.73%) complications. Cardiac tamponade (five cases - 0.18%) and phrenic nerve palsy (one case - 0.04%) rates were very low. Major vascular complications necessitating surgery or blood transfusion occurred in five patients (0.18%). There were no cases of death, permanent disability, atrio-oesophageal fistulae or symptomatic pulmonary vein (PV) stenosis, although there were five TEE probe-related complications (0.18%). Female gender (OR 2.14; 95% CI 1.07-4.26) but not age >70 (OR 1.01) was the only multivariate predictor of complications. Atrial fibrillation ablation performed at a high-volume centre using RF can be achieved with a low major complication rate in a representative AF population over a sustained period of time. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights

  1. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    PubMed

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (P<0.01); prediction equations overestimated at lower values and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  2. Evaluation of a Mobile Phone Image-Based Dietary Assessment Method in Adults with Type 2 Diabetes.

    PubMed

    Rollo, Megan E; Ash, Susan; Lyons-Wall, Philippa; Russell, Anthony W

    2015-06-17

    Image-based dietary records have limited evidence evaluating their performance and use among adults with a chronic disease. This study evaluated the performance of a 3-day mobile phone image-based dietary record, the Nutricam Dietary Assessment Method (NuDAM), in adults with type 2 diabetes mellitus (T2DM). Criterion validity was determined by comparing energy intake (EI) with total energy expenditure (TEE) measured by the doubly-labelled water technique. Relative validity was established by comparison to a weighed food record (WFR). Inter-rater reliability was assessed by comparing estimates of intake from three dietitians. Ten adults (6 males, age: 61.2 ± 6.9 years old, BMI: 31.0 ± 4.5 kg/m(2)) participated. Compared to TEE, mean EI (MJ/day) was significantly under-reported using both methods, with a mean ratio of EI:TEE 0.76 ± 0.20 for the NuDAM and 0.76 ± 0.17 for the WFR. Correlations between the NuDAM and WFR were mostly moderate for energy (r = 0.57), carbohydrate (g/day) (r = 0.63, p < 0.05), protein (g/day) (r = 0.78, p < 0.01) and alcohol (g/day) (rs = 0.85, p < 0.01), with a weaker relationship for fat (g/day) (r = 0.24). Agreement between dietitians for nutrient intake for the 3-day NuDAM (Intra-class Correlation Coefficient (ICC) = 0.77-0.99) was lower when compared with the 3-day WFR (ICC = 0.82-0.99). These findings demonstrate the performance and feasibility of the NuDAM to assess energy and macronutrient intake in a small sample. Some modifications to the NuDAM could improve efficiency and an evaluation in a larger group of adults with T2DM is required.

  3. Evaluation of antibacterial activity, phytochemical constituents, and cytotoxicity effects of Thai household ancient remedies.

    PubMed

    Chusri, Sasitorn; Sinvaraphan, Naruephan; Chaipak, Ploypailin; Luxsananuwong, Atita; Voravuthikunchai, Supayang Piyawan

    2014-12-01

    Household ancient remedies reported here are described in the National List of Essential Medicines and have traditionally been used in Thailand to treat infection-related ailments. However, the safety and effectiveness of these remedies have been poorly evaluated. The aim of this study was to evaluate the antibacterial properties of these remedies against seven gram-positive and gram-negative multidrug-resistant bacteria species. Phytochemical constituents and cytotoxicity of these remedies were also determined. Seven remedies, consisting of Um-Ma-Luk-Ka-Wa-Tee, Chan-Ta-Lee-La, Kheaw-Hom, Learng-Pid-Sa-Mud, Pra-Sa-Chan-Dang, Dhart-Ban-Chob, and Tree-Hom, were prepared by a licensed traditional medical doctor using a mixture of medicinal plants. Antibacterial activity of ethanol extracts of the remedies was determined by using a broth microdilution method. Qualitative phytochemical screening analysis was carried out to identify the presence of major components. Cytotoxicity activities of the extracts against Vero cells were assessed by green fluorescent protein-based assay. With the exception of Dhart-Ban-Chob extract, significant minimum inhibitory concentrations (MICs) of <16 to 32 μg/mL were observed for the remedy extracts depending on the bacterial strains. The Um-Ma-Luk-Ka-Wa-Tee extract was noncytotoxic against Vero cells and possessed the highest activity, with MICs of <16 to 31 μg/mL against all methicillin-resistant Staphylococcus aureus isolates. Remarkable antibacterial activities against multidrug-resistant pathogens, as well as low toxicity on Vero cells, of Um-Ma-Luk-Ka-Wa-Tee support the use of this remedy in traditional medicine. Further investigation on other biological activities related to traditional applications, appropriate biomarkers, and treatment mechanisms of the household remedy are required.

  4. Short-term safety and efficacy of left atrial appendage closure with the WATCHMAN device in patients with small left atrial appendage ostia.

    PubMed

    Venkataraman, Ganesh; Strickberger, S Adam; Doshi, Shephal; Ellis, Christopher R; Lakkireddy, Dhanunjaya; Whalen, S Patrick; Cuoco, Frank

    2018-01-01

    Left atrial appendage (LAA) closure with the WATCHMAN device, according to FDA labelling, is recommended in patients with a maximal LAA ostial width between 17 and 31 mm. The safety and efficacy of LAA closure in patients with a maximal LAA ostial width < 17 mm has not been evaluated. The goal of this study was to determine the acute and short-term safety and efficacy of LAA closure with the WATCHMAN device in patients with a maximal LAA ostial width < 17 mm. Thirty-two consecutive patients with a maximal LAA ostial width < 17 mm as determined by a screening transesophageal echocardiogram (TEE) underwent LAA closure with the WATCHMAN device between March 2015 and November 2016 at five medical centers, and were included in this study. Mean age, body mass index (BMI), and CHA 2 DS 2 -VASC score were 70.8 ± 8.6 years, 29.3 ± 6.5 kg/m 2 , and 3.9 ±1.2, respectively. At the screening TEE, mean maximal LAA ostial width and depth were 15.6 ± 0.6 mm (range 14-16) and 23.2 ± 4.5 mm (range 13-31), respectively. Successful LAA closure with the WATCHMAN device was achieved in 31 of 32 patients (97%), with no major complications. TEE performed 45 days after LAA closure demonstrated no peridevice leak > 5 mm and no device related thrombi. Warfarin was discontinued in all 31 patients 45 days after LAA closure. LAA closure with the WATCHMAN device can be successfully and safely achieved in patients with a maximal LAA ostial width < 17 mm. © 2017 Wiley Periodicals, Inc.

  5. Different indicators for postprocedural mitral stenosis caused by single- or multiple-clip implantation after percutaneous mitral valve repair.

    PubMed

    Itabashi, Yuji; Utsunomiya, Hiroto; Kubo, Shunsuke; Mizutani, Yukiko; Mihara, Hirotsugu; Murata, Mitsushige; Siegel, Robert J; Kar, Saibal; Fukuda, Keiichi; Shiota, Takahiro

    2018-04-01

    Postprocedural mitral stenosis (MS) is a main limitation for MitraClip™ (Abbot Vascular, Inc., Santa Clara, CA, USA) procedure. The purpose of this study was to detect the preprocedural predictors of high transmitral pressure gradient (TMPG) after MitraClip™ implantation, which indicated postprocedural mitral stenosis (MS). We studied 79 patients who were implanted with MitraClip™ in our institute. Before the procedure, mitral valve orifice area (MVOA), and anterior-posterior (AP) and medial-lateral (ML) mitral annular diameters were measured at diastole using three-dimensional (3D) transesophageal echocardiography (TEE) data set. After the procedure, the mean TMPG was assessed using continuous-wave (CW) Doppler by periprocedural TEE. Preprocedural MVOA, and AP and ML diameter of left ventricular (LV) inflow orifices were larger in patients with mean TMPG ≤4mmHg than in patients with TMPG >4mmHg after 1-and 2-clip implantation. The large MVOA and ML diameter of LV inflow orifice strongly correlated with the low TMPG after 1- and 2-clip implantation. As a result of the receiver operating characteristic curve analysis, the preprocedural MVOA predicted the low postprocedural TMPG more accurately than the ML diameter of LV inflow orifice after 1-clip implantation either in the degenerative or functional mitral regurgitation (MR) patients. After 2-clip implantation, however, the preprocedural ML diameter of LV inflow orifice predicted it more accurately than the MVOA in the degenerative and functional MR patients. 3D TEE derived MVOA predicts the postprocedural MS after 1-clip implantation, however, preprocedural ML diameter of LV inflow orifice is more useful to predict after 2-clip implantation. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study

    PubMed Central

    Kim, Yun Gi; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796–2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726–16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation. PMID:29360845

  7. [Low molecular weight heparin and non valvular atrial fibrillation].

    PubMed

    Ederhy, S; Di Angelantonio, E; Meuleman, C; Janower, S; Boccara, F; Cohen, A

    2006-12-01

    Low molecular weight heparin (LMWH) are obtained through chemical or enzyme depolymerisation of unfractioned heparins (UFH). LMWHs present several advantages over UFH: they exhibit a smaller interindividual variability of the anticoagulant effect, they have a greater bioavailability, a longer plasma half-life and do not require monitoring of the anticoagulant effect. LMWH have restrictive indications in AF patients, cardioversion (II level C and TEE for ACC/AHA/ESC and 2C for ACCP guidelines) or use as a bridge therapy (IIB, level C for ACC/AHA/ESC). The ACE study (Anticoagulation for cardioversion using enoxaparin), showed a reduction, though not statistically significant, of 42% of the composite end point (embolic event, major bleeding and death) 2.8% under enoxaparin vs. 4.8 % under conventional treatment, relative risk 0.58, CI 95% 0.23-1.46). Other studies, using dalteparin, confirmed that an anticoagulant treatment using LMWH followed by warfarin was at least as good as conventional management. ACUTE II (Assessment of cardioversion using transesophageal echochardiography), a randomized multicenter trial, compared the efficacy and tolerance of enoxaparin (1 mg/kg every 12 hours) and UFH in 155 patients eligible for a TEE-guided cardioversion. These patients were administered LMWH or UFH for 24 hours before TEE or cardioversion. There were no significative differences regarding the incidence of the study end points, in particular stroke and bleeding, and no death occurred. HAEST (Heparin in acute embolic stroke trial), a randomized, placebo-controlled, double blind trial failed to show the LMWH superiority over aspirin in patients with acute ischemic stroke and atrial fibrillation. Finally, LMWH have been proposed as a bridge therapy in patients under chronic VKA prior to surgery or invasive procedures. This strategy resulted in a low rate of thromboembolic events and major bleedings.

  8. Tolerability and safety of the intravenous immunoglobulin octagam® 10% in patients with immune thrombocytopenia: a post-authorisation safety analysis of two non-interventional phase IV trials.

    PubMed

    Wietek, Stefan; Svorc, Daniel; Debes, Anette; Svae, Tor-Einar

    2018-05-01

    To provide detailed data on the tolerability and safety of octagam ® 10%, a ready-to-use intravenous immunoglobulin, in a subgroup of patients with immune thrombocytopenia (ITP) involved in an integrated analysis of post-authorisation safety surveillance (PASS) studies. A subgroup analysis was conducted using data collected from two non-interventional studies that included patients with ITP treated with octagam ® 10%. Patients were observed and monitored for possible adverse drug reactions (ADRs) during or after administration of octagam ® 10%, with a particular focus on thromboembolic events (TEEs). ADRs were analysed at the case and event level. In this analysis of 112 patients receiving octagam ® 10% (mean dose 0.4 g/kg/infusion), there were five cases with at least one adverse drug reaction (ADR) associated with 626 infusions of octagam ® 10% (case incidence of 0.8% per infusion). ADRs were of mild or moderate severity. There were a total of 10 events, most commonly back pain (n = 3) and headache (n = 2). Nausea, dizziness and a sensation of heaviness were also reported. The remaining two events involved drug exposure during pregnancy. There were no TEEs or other serious ADRs. In this subgroup analysis of patients who received octagam ® 10% (manufactured using an amended process) in two PASS studies, the overall ADR rate was low, with ADRs occurring in only 0.8% of all infusions. No TEEs or other serious ADRs were reported. Routine clinical use of octagam ® 10% was safe and well tolerated, with no unexpected safety issues, in patients with ITP. The two studies from which data were taken are registered with the International Standard Randomised Controlled Trial Number Registry, numbers ISRCTN58800347 and ISRCTN02245668.

  9. The temporal response to drought in a Mediterranean evergreen tree: comparing a regional precipitation gradient and a throughfall exclusion experiment.

    PubMed

    Martin-Stpaul, Nicolas K; Limousin, Jean-Marc; Vogt-Schilb, Hélène; Rodríguez-Calcerrada, Jesus; Rambal, Serge; Longepierre, Damien; Misson, Laurent

    2013-08-01

    Like many midlatitude ecosystems, Mediterranean forests will suffer longer and more intense droughts with the ongoing climate change. The responses to drought in long-lived trees differ depending on the time scale considered, and short-term responses are currently better understood than longer term acclimation. We assessed the temporal changes in trees facing a chronic reduction in water availability by comparing leaf-scale physiological traits, branch-scale hydraulic traits, and stand-scale biomass partitioning in the evergreen Quercus ilex across a regional precipitation gradient (long-term changes) and in a partial throughfall exclusion experiment (TEE, medium term changes). At the leaf scale, gas exchange, mass per unit area and nitrogen concentration showed homeostatic responses to drought as they did not change among the sites of the precipitation gradient or in the experimental treatments of the TEE. A similar homeostatic response was observed for the xylem vulnerability to cavitation at the branch scale. In contrast, the ratio of leaf area over sapwood area (LA/SA) in young branches exhibited a transient response to drought because it decreased in response to the TEE the first 4 years of treatment, but did not change among the sites of the gradient. At the stand scale, leaf area index (LAI) decreased, and the ratios of stem SA to LAI and of fine root area to LAI both increased in trees subjected to throughfall exclusion and from the wettest to the driest site of the gradient. Taken together, these results suggest that acclimation to chronic drought in long-lived Q. ilex is mediated by changes in hydraulic allometry that shift progressively from low (branch) to high (stand) organizational levels, and act to maintain the leaf water potential within the range of xylem hydraulic function and leaf photosynthetic assimilation. © 2013 John Wiley & Sons Ltd.

  10. Racial differences in thoracic aorta atherosclerosis among ischemic stroke patients.

    PubMed

    Gupta, Vishal; Nanda, Navin C; Yesilbursa, Dilek; Huang, Wen Ying; Gupta, Vijaya; Li, Qing; Gomez, Camilo R

    2003-02-01

    Atherosclerosis of the thoracic aorta is an independent risk factor for stroke. There is little information on the impact of race in the prevalence of thoracic aorta atherosclerotic plaques among ischemic stroke patients. This study was an attempt to objectively assess the prevalence, thickness, and burden of thoracic aorta atherosclerotic plaques in a large population of ischemic stroke patients and to compare the differences between American blacks and whites. This is a retrospective study of clinical data and transesophageal echocardiography (TEE) of 1553 ischemic stroke patients (664 blacks, 889 whites) over a period of 4.5 years. Atherosclerotic plaque prevalence, thickness, morphology, and burden (sum of maximum thickness in ascending aorta [AA], aortic arch [AO], and descending aorta [DA]) were assessed with TEE. Charts were reviewed for clinical information. Age and sex were similar among blacks and whites. Analyses of clinical data found that blacks had significantly higher hypertension (odds ratio [OR], 2.61; P<0.0001) and diabetes mellitus (OR, 1.99; P<0.0001) and significantly lower coronary artery disease (OR, 0.75; P=0.017) and carotid artery disease (OR, 0.62; P=0.0008) compared with whites. TEE showed that whites had significantly greater plaque prevalence (AA: OR, 1.37; P=0.04; AO: OR, 1.26; P=0.03; DA: OR, 1.39; P=0.002) and plaque burden (blacks, 4.28 mm; whites, 4.97 mm; P=0.007). Whites also had a trend of increased complex plaques and plaques >4 mm thick in all regions of the thoracic aorta. Among ischemic stroke patients, blacks had a lower prevalence of extra cranial atherosclerotic disease even though they had significantly higher hypertension and diabetes mellitus compared with whites. This difference cannot be explained by the existing risk factors in ischemic stroke patients.

  11. Evaluation of Antibacterial Activity, Phytochemical Constituents, and Cytotoxicity Effects of Thai Household Ancient Remedies

    PubMed Central

    Sinvaraphan, Naruephan; Chaipak, Ploypailin; Luxsananuwong, Atita; Voravuthikunchai, Supayang Piyawan

    2014-01-01

    Abstract Aim: Household ancient remedies reported here are described in the National List of Essential Medicines and have traditionally been used in Thailand to treat infection-related ailments. However, the safety and effectiveness of these remedies have been poorly evaluated. The aim of this study was to evaluate the antibacterial properties of these remedies against seven gram-positive and gram-negative multidrug-resistant bacteria species. Phytochemical constituents and cytotoxicity of these remedies were also determined. Methods: Seven remedies, consisting of Um-Ma-Luk-Ka-Wa-Tee, Chan-Ta-Lee-La, Kheaw-Hom, Learng-Pid-Sa-Mud, Pra-Sa-Chan-Dang, Dhart-Ban-Chob, and Tree-Hom, were prepared by a licensed traditional medical doctor using a mixture of medicinal plants. Antibacterial activity of ethanol extracts of the remedies was determined by using a broth microdilution method. Qualitative phytochemical screening analysis was carried out to identify the presence of major components. Cytotoxicity activities of the extracts against Vero cells were assessed by green fluorescent protein–based assay. Results: With the exception of Dhart-Ban-Chob extract, significant minimum inhibitory concentrations (MICs) of <16 to 32 μg/mL were observed for the remedy extracts depending on the bacterial strains. The Um-Ma-Luk-Ka-Wa-Tee extract was noncytotoxic against Vero cells and possessed the highest activity, with MICs of <16 to 31 μg/mL against all methicillin-resistant Staphylococcus aureus isolates. Conclusions: Remarkable antibacterial activities against multidrug-resistant pathogens, as well as low toxicity on Vero cells, of Um-Ma-Luk-Ka-Wa-Tee support the use of this remedy in traditional medicine. Further investigation on other biological activities related to traditional applications, appropriate biomarkers, and treatment mechanisms of the household remedy are required. PMID:25415453

  12. Energy Metabolism Profile in Individuals with Prader-Willi Syndrome and Implications for Clinical Management: A Systematic Review.

    PubMed

    Alsaif, Maha; Elliot, Sarah A; MacKenzie, Michelle L; Prado, Carla M; Field, Catherine J; Haqq, Andrea M

    2017-11-01

    Prader-Willi syndrome (PWS) is a rare genetic disorder associated with excessive weight gain. Hyperphagia associated with PWS may result in higher energy intake, but alterations in energy expenditure may also contribute to energy imbalance. The purpose of this critical literature review is to determine the presence of alterations in energy expenditure in individuals with PWS. Ten studies that measured total energy expenditure (TEE), resting energy expenditure (REE), sleep energy expenditure (SEE), activity energy expenditure (AEE), and diet induced thermogenesis (DIT) were included in this review. The studies provided evidence that absolute TEE, REE, SEE, and AEE are lower in individuals with PWS than in age-, sex-, and body mass index-matched individuals without the syndrome. Alterations in lean body mass and lower physical activity amounts appear to be responsible for the lower energy expenditure in PWS rather than metabolic differences. Regardless of the underlying mechanism for lower TEE, the estimation of energy requirements with the use of equations derived for the general population would result in weight gain in individuals with PWS. The determination of energy requirements for weight management in individuals with PWS requires a more comprehensive understanding of energy metabolism. Future studies should aim to comprehensively profile all specific components of energy expenditure in individuals with PWS with the use of appropriately matched controls and gold standard methods to measure energy metabolism and body composition. One component of energy expenditure that is yet to be explored in detail in PWS is DIT. A reduced DIT (despite differences in fat free mass), secondary to hormonal dysregulation, may be present in PWS individuals, leading to a reduced overall energy expenditure. Further research exploring DIT in PWS needs to be conducted. Dietary energy recommendations for weight management in PWS have not yet been clearly established. © 2017 American

  13. Biliopancreatic Diversion is associated with greater increases in energy expenditure than Roux-en-Y Gastric Bypass.

    PubMed

    Werling, Malin; Fändriks, Lars; Olbers, Torsten; Mala, Tom; Kristinsson, Jon; Stenlöf, Kaj; Wallenius, Ville; Docherty, Neil G; le Roux, Carel W

    2018-01-01

    The greater weight loss achieved following Biliopancreatic Diversion with Duodenal Switch (BPDS) versus Roux-en-Y Gastric Bypass (RYGB) has been attributed to the malabsorptive effects of BPDS. Increased weight loss after BPDS could also be underpinned by larger increases in energy expenditure. Hypothetically, the more radical reconfiguration of the small intestine in BPDS could result in an accentuated increase in meal associated thermogenesis (MAT). Female subjects (baseline mean age 40 years, mean BMI-55kg/m2) were assessed four years after randomization to BPDS (n = 6) or RYGB (n = 6). Energy expenditure (EE) and respiratory quotient (RQ) were measured by indirect calorimetry over 24 hours. A detailed protocol allowed for discrimination of basal metabolic rate (BMR), fasting EE and MAT as components of total energy expenditure (TEE) normalised for total and lean tissue by dual-energy x-ray absorptiometry. Median weight loss at follow-up was 1.5-fold higher following BPDS relative to RYGB, resulting in respective median BMIs of 29.5 kg/m2 (21.7 to 36.7) after BPDS and 37.8 kg/m2 (34.1 to 45.7) after RYGB (p = 0.015). The BPDS group had a lower fat:lean ratio compared to the RYGB group (p = 0.009). Overall 24-hour TEE adjusted for total tissue was higher in the BPDS group, as were BMR, fasting EE and MAT (all p<0.05). Differences between RYGB and BPDS in BMR and TEE were nullified when normalised for lean mass. Postprandial RQ increased significantly but to a similar extent in both groups. Enhanced and prolonged MAT and lower fat:lean mass ratios after BPDS may explain relative increases in total energy expenditure as compared to RYGB.

  14. Biliopancreatic Diversion is associated with greater increases in energy expenditure than Roux-en-Y Gastric Bypass

    PubMed Central

    Werling, Malin; Fändriks, Lars; Olbers, Torsten; Mala, Tom; Kristinsson, Jon; Stenlöf, Kaj; Wallenius, Ville; le Roux, Carel W.

    2018-01-01

    Objective The greater weight loss achieved following Biliopancreatic Diversion with Duodenal Switch (BPDS) versus Roux-en-Y Gastric Bypass (RYGB) has been attributed to the malabsorptive effects of BPDS. Increased weight loss after BPDS could also be underpinned by larger increases in energy expenditure. Hypothetically, the more radical reconfiguration of the small intestine in BPDS could result in an accentuated increase in meal associated thermogenesis (MAT). Design Female subjects (baseline mean age 40 years, mean BMI-55kg/m2) were assessed four years after randomization to BPDS (n = 6) or RYGB (n = 6). Energy expenditure (EE) and respiratory quotient (RQ) were measured by indirect calorimetry over 24 hours. A detailed protocol allowed for discrimination of basal metabolic rate (BMR), fasting EE and MAT as components of total energy expenditure (TEE) normalised for total and lean tissue by dual-energy x-ray absorptiometry. Results Median weight loss at follow-up was 1.5-fold higher following BPDS relative to RYGB, resulting in respective median BMIs of 29.5 kg/m2 (21.7 to 36.7) after BPDS and 37.8 kg/m2 (34.1 to 45.7) after RYGB (p = 0.015). The BPDS group had a lower fat:lean ratio compared to the RYGB group (p = 0.009). Overall 24-hour TEE adjusted for total tissue was higher in the BPDS group, as were BMR, fasting EE and MAT (all p<0.05). Differences between RYGB and BPDS in BMR and TEE were nullified when normalised for lean mass. Postprandial RQ increased significantly but to a similar extent in both groups. Conclusion Enhanced and prolonged MAT and lower fat:lean mass ratios after BPDS may explain relative increases in total energy expenditure as compared to RYGB. PMID:29617391

  15. Combined Aerobic/Strength Training and Energy Expenditure in Older Women

    PubMed Central

    Hunter, Gary R.; Bickel, C. Scott; Fisher, Gordon; Neumeier, William; McCarthy, John

    2013-01-01

    Purpose To examine the effects of three different frequencies of combined resistance and aerobic training on total energy expenditure (TEE) and activity related energy expenditure (AEE) in a group of older adults. Methods Seventy-two women, 60 – 74 years old, were randomly assigned to one of three groups: 1 day/week of aerobic and 1 day/week of resistance (1+1); 2 days/week of aerobic and 2 days/week resistance (2+2); or 3 days/week aerobic and 3 days/week resistance (3+3). Body composition (DXA), feeling of fatigue, depression, and vigor (questionnaire), strength (1RM), serum cytokines (ELISA), maximal oxygen uptake (progressive treadmill test), resting energy expenditure, and TEE were measured before and after 16 weeks of training. Aerobic training consisted of 40 minutes of aerobic exercise at 80% maximum heart rate and resistance training consisted of 2 sets of 10 repetitions for 10 different exercises at 80% of one repetition maximum. Results All groups increased fat free mass, strength and aerobic fitness and decreased fat mass. No changes were observed in cytokines or perceptions of fatigue/depression. No time by group interaction was found for any fitness/body composition variable. TEE and AEE increased with the 2+2 group but not with the other two groups. Non-exercise training AEE (NEAT) increased significantly in the 2+2 group (+200 kcal/day), group 1×1 showed a trend for an increase (+68 kcal/day) and group 3+3 decreased significantly (−150 kcal/day). Conclusion Results indicate that 3+3 training may inhibit NEAT by being too time consuming and does not induce superior training adaptations to 1+1 and 2+2 training. Key words: physical activity, older adults, total energy expenditure, maximum oxygen uptake. PMID:23774582

  16. The Role of Patent Foramen Ovale in Cryptogenic Stroke.

    PubMed

    Şenadim, Songül; Bozkurt, Dilek; Çabalar, Murat; Bajrami, Arsida; Yayla, Vildan

    2016-03-01

    Almost one-third of ischemic strokes has an unknown etiology and are classified as cryptogenic stroke. Paradoxical embolism because of a patent foramen ovale (PFO) is detected in 40%-50% of these patients. Recently, PFO has been reported as a risk factor for patients of all age groups. In this study, 1080 ischemic stroke patients admitted to our clinic (2011-2013) were retrospectively evaluated. Age, sex, risk factors, complete blood count, vasculitis, biochemical and hypercoagulability tests, magnetic resonance imaging, magnetic resonance angiography, transthoracic echocardiography, transeosophageal echocardiography (TEE) findings, and therapeutic approaches were evaluated. The age range of the participants (seven male and four female patients) was 20-60 years (mean=43.09±11.13 years). Hemiparesis (n=10), diplopia (n=2), hemianopsia (n=2), and dysarthria (n=2) were the main findings of the neurological examinations. Patient medical history revealed hypertension (n=3), asthma (n=1), deep venous thrombosis (n=1), and smoking (n=4). Diffusion-weighted imaging showed middle cerebral artery (n=8) and posterior cerebral artery (n=3) infarctions. In one case, symptomatic severe carotid stenosis was detected. In eight cases, TEE showed PFO without any other abnormalities, but PFO was associated with atrial septal aneurysm in two cases, and in one case it was associated with ventricular hypokinesia and pulmonary arterial hypertension. Antiplatelet therapy was applied to nine patients and percutaneous PFO closure operation to two patients. In a 2-year follow-up, no recurrent ischemic stroke was recorded. PFO, especially in terms of the etiology of cryptogenic stroke in young patients, should not be underestimated. We want to emphasize the importance of TEE in identifying potential cardioembolic sources not only in young but also in all ischemic stroke patients with unknown etiology; we also discuss the controversial management options of PFO.

  17. Frequency of Dietary Recalls, Nutritional Assessment, and Body Composition Assessment in Men With Chronic Spinal Cord Injury.

    PubMed

    Gorgey, Ashraf S; Caudill, Caleb; Sistrun, Sakita; Khalil, Refka E; Gill, Ranjodh; Castillo, Teodoro; Lavis, Timothy; Gater, David R

    2015-09-01

    To assess different frequencies of dietary recalls while evaluating caloric intake and the percentage of macronutrients in men with spinal cord injury (SCI) and to examine the relations between caloric intake or percentage of macronutrients and assessment of whole and regional body composition using dual-energy x-ray absorptiometry. Cross-sectional and longitudinal. Laboratory and hospital. Men with chronic (>1 y postinjury) motor complete SCI (N=16). Participants were asked to turn in a 5-day dietary recall on a weekly basis for 4 weeks. The averages of 5-, 3-, and 1-day dietary recalls for caloric intake and percentage of macronutrients (carbohydrates, fat, protein) were calculated. Body composition was evaluated using whole-body dual-energy x-ray absorptiometry. After overnight fast, basal metabolic rate (BMR) was evaluated using indirect calorimetry and total energy expenditure (TEE) was estimated. Caloric intake, percentage of macronutrients, BMR, and body composition. Caloric intake and percentage of macronutrients were not different after using 5-, 3-, and 1-day dietary recalls (P>.05). Caloric intake was significantly lower than TEE (P<.05). The percentage of fat accounted for 29% to 34% of the whole and regional body fat mass (P=.037 and P=.022). The percentage of carbohydrates was positively related to the percentage of whole-body lean mass (r=.54; P=.037) and negatively related to the percentage of fat mass. The frequency of dietary recalls does not vary while evaluating caloric intake and macronutrients. Total caloric intake was significantly lower than the measured BMR and TEE. Percentages of dietary fat and carbohydrates are related to changes in body composition after SCI. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Triple-orifice valve repair in severe Barlow disease with multiple-jet mitral regurgitation: report of mid-term experience.

    PubMed

    Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto

    2013-09-10

    Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Observations on the use of GYPCHEK

    Treesearch

    F. B. Lewis; R. C. Reardon; A. S. Munson; H. B. Hubbard; N. F. Schneeberger; W. B. White

    1979-01-01

    This paper reports the results of the 1978 aerial test with the gypsy moth NPV product, GYPCHEK. Although a general population collapse was observed, conclusions could be made on the efficacy of three formulations and two aircraft nozzling systems. The molasses formulation was more effective when applied with Beecomist® nozzles, but Pro-tee®...

  20. Buddhist Pedagogy in Teacher Education: Cultivating Wisdom by Skillful Means

    ERIC Educational Resources Information Center

    Ma Rhea, Zane

    2018-01-01

    This paper draws on research I have conducted about the cultivation of wisdom in Thailand and Australia. I examine the ancient pedagogy of pavi?aupaya skillful means investigating how this pedagogy can inform contemporary development of teacher educators and teachers. I examine the Panjaawi´tee Wisdom Method that has its foundations in the…

  1. Identification of letters in the predesignated target paradigm: a word superiority effect for the common word the.

    PubMed

    Peterzell, D H; Sinclair, G P; Healy, A F; Bourne, L E

    1990-01-01

    The size of the perceptual unit used in reading was addressed using the predesignated target paradigm. Sixteen subjects viewed the following stimuli in random order: the words tee, the, tie, and toe; the nonwords eet, eht, eit, and eot; and the letters e, h, i, and o. Subjects fixated on the location of the center letter and identified the letter as e, h, i, or o, alternatives which were known to them at the onset. A word superiority effect was obtained for the common word the but not for the less common words tee, tie, and toe. The word superiority effect was attributable to bias rather than discriminability: Subjects exhibited a bias to perceive the words in this experiment as the (i.e., there was a bias to perceive h in the t e stimulus presentations). These results suggest that the common word the is processed in reading units that are larger than the letter, and that the system is biased to perceive common rather than uncommon words in data-limited conditions.

  2. Mobility-Selected Ion Trapping and Enrichment Using Structures for Lossless Ion Manipulations

    DOE PAGES

    Chen, Tsung-Chi; Ibrahim, Yehia M.; Webb, Ian K.; ...

    2016-01-11

    The integration of ion mobility spectrometry (IMS) with mass spectrometry (MS) and the ability to trap ions in IMS-MS measurements is of great importance for performing reactions, accumulating ions, and increasing analytical measurement sensitivity. The development of Structures for Lossless Ion Manipulations (SLIM) offers the potential for ion manipulations in a more reliable and cost-effective manner, while opening opportunities for much more complex sequences of manipulations. Here, we demonstrate an ion separation and trapping module and a method based upon SLIM that consists of a linear mobility ion drift region, a switch/tee and a trapping region that allows the isolationmore » and accumulation of mobility-separated species. The operation and optimization of the SLIM switch/tee and trap are described and demonstrated for the enrichment of the low abundance ions. Lastly, we observed a linear increase in ion intensity with the number of trapping/accumulation events using the SLIM trap, illustrating its potential for enhancing the sensitivity of low abundance or targeted species.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Tsung-Chi; Ibrahim, Yehia M.; Webb, Ian K.

    The integration of ion mobility spectrometry (IMS) with mass spectrometry (MS) and the ability to trap ions in IMS-MS measurements is of great importance for performing reactions, accumulating ions, and increasing analytical measurement sensitivity. The development of Structures for Lossless Ion Manipulations (SLIM) offers the potential for ion manipulations in a more reliable and cost-effective manner, while opening opportunities for much more complex sequences of manipulations. Here, we demonstrate an ion separation and trapping module and a method based upon SLIM that consists of a linear mobility ion drift region, a switch/tee and a trapping region that allows the isolationmore » and accumulation of mobility-separated species. The operation and optimization of the SLIM switch/tee and trap are described and demonstrated for the enrichment of the low abundance ions. Lastly, we observed a linear increase in ion intensity with the number of trapping/accumulation events using the SLIM trap, illustrating its potential for enhancing the sensitivity of low abundance or targeted species.« less

  4. Basswood, linden, lime-tree,

    Treesearch

    John Zasada

    2003-01-01

    Tilia americana - to foresters, botanists, and ecologists around the world this name conjures up the picture of a very specific tree (Tilia in latin means linden tree so literally translated the scientific name means American linden). But what about basswood, linden, lime, and pu tee shu (Chinese for linden)? Common names are often confusing and may be different from...

  5. Marvelous Mud

    ERIC Educational Resources Information Center

    Keeler, Rusty

    2011-01-01

    The author visited the Open Spaces Preschool in Whangarei, New Zealand and was surprised to see the most amazing natural preschool play. There were six preschoolers stripped down to tee shirts and underpants slipping, slopping, and sliding in the dirt spot which had now become the most lovely, silky-smooth deep-brown mud ever. Studies have…

  6. Perceived Benefits and Attitudes of Student Teachers to Web-Quest as a Motivating, Creative and Inquiry-Based Learning Tool in Education

    ERIC Educational Resources Information Center

    Aina, Samuel Ayobami; Sofowora, Alaba Olaniyi

    2013-01-01

    This study discussed how the Department of Teacher Education, University of Ibadan utilized Web-Quest as a motivating and creative tool to teach a compulsory and large pre-service teachers' Course (TEE 304) The study also investigated the attitude and perception of pre-service teachers to the use of Web-Quest. The results showed that the sample…

  7. Perceptual Narrowing of Linguistic Sign Occurs in the 1st Year of Life

    ERIC Educational Resources Information Center

    Palmer, Stephanie Baker; Fais, Laurel; Golinkoff, Roberta Michnick; Werker, Janet F.

    2012-01-01

    Over their 1st year of life, infants' "universal" perception of the sounds of language narrows to encompass only those contrasts made in their native language (J. F. Werker & R. C. Tees, 1984). This research tested 40 infants in an eyetracking paradigm and showed that this pattern also holds for infants exposed to seen language--American Sign…

  8. 40 CFR 1066.110 - Equipment specifications for emission sampling systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., such as orifice plates or fins, to achieve good mixing; this may be necessary for good mixing if Re# is... condensation. (v) If you choose to dilute the exhaust by using a remote mix tee, which dilutes the exhaust at... polymer-based materials. (D) Use good engineering judgment to ensure that the materials you choose do not...

  9. Teacher Candidate Fashion, Tattoos, and Piercings: Finding Balance and Common Sense

    ERIC Educational Resources Information Center

    Colbert, Ron

    2008-01-01

    The season of new buds and blossoms also signals fashion changes in the college classroom. Shorts, short skirts, tees, muscle tops, underwear exposed by low-rise pants, hospital scrubs, and flip-flops appear. With the advent of warm weather, women's clothing style can be tight and/or revealing. Jewelry and accessories become more visible. Today,…

  10. Lessons Learned from the Private Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robichaud, Robert J

    This session is focused on lessons learned from private sector energy projects that could be applied to the federal sector. This presentation tees up the subsequent presentations by outlining the differences between private and federal sectors in objectives, metrics for determining success, funding resources/mechanisms, payback and ROI evaluation, risk tolerance/aversion, new technology adoption perspectives, and contracting mechanisms.

  11. Conference Proceedings for Optical Fiber Sensors Conference (8th) held in Monterey, California on January 29 - 31 1992

    DTIC Science & Technology

    1992-01-01

    Research Center, East Hartford, CT Program Chair Anthony Dandridge Naval Research Laboratory, Washington, DC PROGRAM COMMnrTEE KIIIl BIetekjaer WAilliam W...Moray Norwegian knst. of Technology, Norway tkited Technologies Research Center, East Hartford, CT Jacek Chrostowski Julchl Noda National Research ...Technology, Boulder, CO Aa .Rgr Shacul Ezekiel *Vngs College, London, United lingdomn MIT, Lexington, MA Pee J. Samson Masamltsu Haruna BHP Central Research

  12. The Influence of a Lower Heated Tube on Nucleate Pool Boiling from a Horizontal Tube

    DTIC Science & Technology

    1992-06-01

    9 C. CONDENSER SECTION .................................... 12 D. COOLING SECTION...lower tube kc thermal conductivity of copper L active boiling tube length Lu non-boiling tube length x Nu Nusselt number p tube outside wall perimeter Pr...teflon endplates. 2. A condenser , assembled using a similar Pyrex-glass tee with aluminum endplates. 3. A reservoir for R- 114 liquid storage. 4. A

  13. Compact Magic-T using microstrip-slotline transitions

    NASA Technical Reports Server (NTRS)

    U-Yen, Kongpop (Inventor); Wollack, Edward J. (Inventor); Doiron, Terence (Inventor); Moseley, Samuel H. (Inventor)

    2010-01-01

    The design of a compact low-loss Magic-T is described. The planar Magic-T incorporates a compact microstrip-slotline tee junction and small microstrip-slotline transition area to reduce slotline radiation. The Magic-T produces broadband in-phase and out-of-phase power combiner/divider responses, has low in-band insertion loss, and small in-band phase and amplitude imbalance.

  14. Antarctic Atmospheric Infrasound.

    DTIC Science & Technology

    1986-11-01

    subject to expansion from solar heating. The solution is lots of RTV goop on the end caps and Tee connection. 6.1.4 Land Lines A land line failure will...on the newer cards - 57 - 6, DEMODULATOR CARD CAGE SI Filter-amplifier output Output banana plugs 5.6K 2 4I 22 NC 11 Slow-speed analogue Front panal

  15. Estimating Energy Expenditure with the RT3 Triaxial Accelerometer

    ERIC Educational Resources Information Center

    Maddison, Ralph; Jiang, Yannan; Vander Hoorn, Stephen; Mhurchu, Cliona Ni; Lawes, Carlene M. M.; Rodgers, Anthony; Rush, Elaine

    2009-01-01

    The RT3 is a relatively new triaxial accelerometer that has replaced the TriTrac. The aim of this study was to validate the RT3 against doubly labeled water (DLW) in a free-living, mixed weight sample of adults. Total energy expenditure (TEE) was measured over a 15-day period using DLW. Activity-related energy expenditure (AEE) was estimated by…

  16. Oral Health of Patients Treated with Acrylic Partial Dentures Using a Toothpaste Containing Bee Product

    PubMed Central

    Kownacki, Patryk; Tanasiewicz, Marta; Piekarz, Tomasz; Bogacz, Mateusz; Kasperski, Jacek; Niedzielska, Iwona

    2017-01-01

    This study was carried out to investigate the influence of a propolis and tee tree oil-containing hygienic agent on selected oral health parameters, oral microflora, and the condition of periodontal health. Thirty-seven patients who underwent oral rehabilitation with a removable acrylic denture were selected and randomly assigned into two groups: study group (A) which received a newly formulated propolis and tee tree oil-containing toothpaste or a control group (C) without an active ingredient. API, S-OHI, and mSBI were assessed in three subsequent stages. During each examination swabs were employed for microbiological inoculation: in the study group after 4 weeks use of the active toothpaste showed a decrease in the number of isolated microorganisms. In the control group, after 4 weeks use of the toothpaste without active ingredients resulted in increase in the number of the isolated microorganisms. Improvements in hygiene and the condition of periodontium were observed in patients using active toothpastes. In the study group the oral flora diversity was reduced by the decrease in the number of cultured microorganism species, while in the control group an increase in the number of cultured microorganisms and their species was observed. PMID:28265291

  17. High prevalence of patent foramen ovale in migraine with aura.

    PubMed

    Ferrarini, Giovanni; Malferrari, Giovanni; Zucco, Riccardo; Gaddi, Oscar; Norina, Marcello; Pini, Luigi Alberto

    2005-04-01

    In this study we evaluated the presence of patent foramen ovale (PFO) in a cohort of 25 consecutive patients suffering from migraine with aura (MA) during an attack presenting to the emergency ward of an Italian hospital. Patients underwent brain magnetic resonance imaging (MRI) with contrast medium, routine coagulation tests, contrast transcranial echocolour-coded sonography (c-TCCS) and transoesophageal echocardiography (TEE). Of the enrolled patients, 88.7% showed a PFO according to the c-TCCS test, whereas only in 72% TEE confirmed the presence of PFO. This discordance could be due to the fact that c-TCCS is more sensitive even with shunts with minimal capacity also located in the pulmonary vasculature. After surgical treatment of the PFO, MA disappeared within two months. Also, the treatment with warfarin as well as with acetylsalicylic acid and flunarizine was able to dramatically reduce the frequency of migraine attacks. These data indicate a higher prevalence of PFO in MA vs. normal population (OR=2.92) and could suggest that the presence of arteriovenous (AV) shunts could represent a trigger for MA attacks as well as for stroke, but more studies are needed to confirm this preliminary hypothesis.

  18. Laparoscopic left lobe liver resection in a porcine model: a study of the efficacy and safety of different surgical techniques.

    PubMed

    Eiriksson, Kristinn; Kristinn, Eiriksson; Fors, Diddi; Diddi, Fors; Rubertsson, Sten; Sten, Rubertsson; Arvidsson, Dag; Dag, Arvidsson

    2009-05-01

    Laparoscopic liver surgery is evolving and the best technique for dividing the liver parenchyma is currently under debate. The aim of this study was to study different techniques during a full laparoscopic lobe resection, and determine the efficacy and risks of bleeding and gas embolism. Sixteen pigs were randomized to two groups: group US underwent an operation with Ultracision shears (AutoSonix) and ultrasonic dissector (CUSA) and group VS with a vessel sealing system (Ligasure) and ultrasonic dissector. A left lobe resection was performed. Transesophageal endoscopic echocardiography (TEE) was used to detect gas emboli in the right side of the heart and pulmonary artery. The operations and TEE were recorded for later assessment. Compared with group VS, group US exhibited significantly more intraoperative bleeding (p = 0.02), a trend towards a longer operation time (p = 0.08), and a trend towards more embolization for grade I emboli. In total, 10 of 15 animals had emboli during the operation. This study showed that a laparoscopic left lobe resection can be performed with a combination of AutoSonix and CUSA as well as with Ligasure and CUSA instrumentation. In our hands, less bleeding was incurred with Ligasure than with AutoSonix.

  19. Feasibility of rapid and automated importation of 3D echocardiographic left ventricular (LV) geometry into a finite element (FEM) analysis model

    PubMed Central

    Verhey, Janko F; Nathan, Nadia S

    2004-01-01

    Background Finite element method (FEM) analysis for intraoperative modeling of the left ventricle (LV) is presently not possible. Since 3D structural data of the LV is now obtainable using standard transesophageal echocardiography (TEE) devices intraoperatively, the present study describes a method to transfer this data into a commercially available FEM analysis system: ABAQUS©. Methods In this prospective study TomTec LV Analysis TEE© Software was used for semi-automatic endocardial border detection, reconstruction, and volume-rendering of the clinical 3D echocardiographic data. A newly developed software program MVCP FemCoGen©, written in Delphi, reformats the TomTec file structures in five patients for use in ABAQUS and allows visualization of regional deformation of the LV. Results This study demonstrates that a fully automated importation of 3D TEE data into FEM modeling is feasible and can be efficiently accomplished in the operating room. Conclusion For complete intraoperative 3D LV finite element analysis, three input elements are necessary: 1. time-gaited, reality-based structural information, 2. continuous LV pressure and 3. instantaneous tissue elastance. The first of these elements is now available using the methods presented herein. PMID:15473901

  20. The variable and chaotic nature of professional golf performance.

    PubMed

    Stöckl, Michael; Lamb, Peter F

    2018-05-01

    In golf, unlike most other sports, individual performance is not the result of direct interactions between players. Instead decision-making and performance is influenced by numerous constraining factors affecting each shot. This study looked at the performance of PGA TOUR golfers in 2011 in terms of stability and variability on a shot-by-shot basis. Stability and variability were assessed using Recurrence Quantification Analysis (RQA) and standard deviation, respectively. About 10% of all shots comprised short stable phases of performance (3.7 ± 1.1 shots per stable phase). Stable phases tended to consist of shots of typical performance, rather than poor or exceptional shots; this finding was consistent for all shot categories. Overall, stability measures were not correlated with tournament performance. Variability across all shots was not related to tournament performance; however, variability in tee shots and short approach shots was higher than for other shot categories. Furthermore, tee shot variability was related to tournament standing: decreased variability was associated with better tournament ranking. The findings in this study showed that PGA TOUR golf performance is chaotic. Further research on amateur golf performance is required to determine whether the structure of amateur golf performance is universal.

  1. Clock Technology Development for the Laser Cooling and Atomic Physics (LCAP) Program

    NASA Technical Reports Server (NTRS)

    Klipstein, W. M.; Thompson, R. J.; Seidel, D. J.; Kohel, J.; Maleki, L.

    1998-01-01

    The Time and Frequency Sciences and Technology Group at Jet Propulsion Laboratory (JPL) has developed a laser cooling capability for flight and has been selected by NASA to support the Laser-Cooling and Atomic Physics (LCAP) program. Current work in the group includes design and development for tee two laser-cooled atomic clock experiments which have been selected for flight on the International Space Station.

  2. Disc Golf: Teaching a Lifetime Activity

    ERIC Educational Resources Information Center

    Eastham, Susan L.

    2015-01-01

    Disc golf is a lifetime activity that can be enjoyed by students of varying skill levels and abilities. Disc golf follows the principles of ball golf but is generally easier for students to play and enjoy success. The object of disc golf is similar to ball golf and involves throwing a disc from the teeing area to the target in as few throws as…

  3. Performance of NACA Eight-Stage Axial-Flow Compressor Designed on the Basis of Airfoil Theory

    DTIC Science & Technology

    1944-08-01

    TEE BASIS OF AIRFOIL THEORY By John T. Slnnette, Jr., Oscar W. Schey, and J. Austin King Aircraft Engine Research Laboratory Cleveland, Ohio FILE...efficiency can he designed by the proper application of airfoil theory. Aircraft Engine Research laboratory, Hational Advisory Committee for Aeronautlos...Basis of Airfoil Theory AUTHORS): Sinnette, John T.; Schey, Oscar W.; and others ORIGINATING AGENCY: Aircraft Engine Research Laboratory, Cleveland

  4. T-section glulam timber bridge modules : modeling and performance

    Treesearch

    Paul A. Morgan; Steven E. Taylor; Michael A. Ritter; John M. Franklin

    1999-01-01

    This paper describes the design, modeling, and testing of two portable timber bridges, each consisting of two noninterconnected longitudinal glued-laminated timber (glulam) deck panels 1.8 m (6 ft) wide. One bridge is 12.2 m (40 ft) long while the other bridge is 10.7 m (35 ft) long. The deck panels are fabricated in a unique double-tee cross section. The bridges...

  5. Investigation of Analog Photonic Link Technology for Timing and Metrological Applications

    DTIC Science & Technology

    2015-05-18

    same model bias tee in each case. Fig. 1.8: Measured residual single-sideband (SSB) phase noise for two amplifiers with various RF pads at...deflection at the AO output. The deflected signal is reflected onto a tilted diffraction grating and passed backed through the device to the output...Other TTD modulation mechanisms have been considered including fiber stretches (mechanical and piezoelectric ), electro-optic modulators (i.e

  6. Tactical Radios: Multiservice Communications Procedures for Tactical Radios in a Joint Environment

    DTIC Science & Technology

    2002-06-01

    joint restricted frequency list (JRFL). It specifies the frequency allocations for communication and jamming missions restricted from use by...coordination commit- tee also builds the frequency list for the mission sets. In building the list, the committee should use JACS or RBECS software...restricted frequency list . A time and geographical listing of prioritized frequencies essential to an operation and restricted from targeting by friendly EP

  7. Electron Excitation of Free-Free Radiation in Argon and of Vibrational States of H2, D2 and O2.

    DTIC Science & Technology

    1983-04-01

    and A. V. Phelps, J. Chen. Phys. (submitted). 19. L. K. Biberman and G. I. Norma , Usp. Piz. Nauk 91, 193 (1967) [Soy. Phys. Uspekii 10, 52 (1967...operated at 3/ of ls tbs x 10"-2 V2. Sae Th. A. ftihow, 3. A. Pogoebein, V. 1. labe45*o. A. X. Rogoahin, ad B. T. Rediomo,, 1b. Omp. Tee. 712. ?, 41 (1909

  8. Exercise training improves fat metabolism independent of total energy expenditure in sedentary overweight men, but does not restore lean metabolic phenotype.

    PubMed

    Lefai, E; Blanc, S; Momken, I; Antoun, E; Chery, I; Zahariev, A; Gabert, L; Bergouignan, A; Simon, C

    2017-12-01

    Obesity is a dietary fat storage disease. Although exercise prevents weight gain, effects of chronic training on dietary fat oxidation remains understudied in overweight adults. We tested whether 2 months of training at current guidelines increase dietary fat oxidation in sedentary overweight adults like in sedentary lean adults. Sedentary lean (n=10) and overweight (n=9) men trained on a cycle ergometer at 50% VO 2peak , 1 h day -1 , four times per week, for 2 months while energy balance was clamped. Metabolic fate of [d 31 ]palmitate and [1- 13 C]oleate mixed in standard meals, total substrate use, total energy expenditure (TEE), activity energy expenditure (AEE) and key muscle proteins/enzymes were measured before and at the end of the intervention. Conversely to lean subjects, TEE and AEE did not increase in overweight participants due to a spontaneous decrease in non-training AEE. Despite this compensatory behavior, aerobic fitness, insulin sensitivity and fat oxidation were improved by exercise training. The latter was not explained by changes in dietary fat trafficking but more likely by a coordinated response at the muscle level enhancing fat uptake, acylation and oxidation (FABPpm, CD36, FATP1, ACSL1, CPT1, mtGPAT). ACSL1 fold change positively correlated with total fasting (R 2 =0.59, P<0.0001) and post-prandial (R 2 =0.49, P=0.0006) fat oxidation whereas mtGPAT fold change negatively correlated with dietary palmitate oxidation (R 2 =0.40, P=0.009), suggesting modified fat trafficking between oxidation and storage within the muscle. However, for most of the measured parameters the post-training values observed in overweight adults remained lower than the pre-training values observed in the lean subjects. Independent of energy balance and TEE, exercise training at current recommendations improved fitness and fat oxidation in overweight adults. However the improved metabolic phenotype of overweight adults was not as healthy as the one of their lean

  9. Efficacy and Safety of Transthoracic Echocardiography Alone in Transcatheter Closure of Secundum-Type Atrial Septal Defects in Adults.

    PubMed

    Ding, Cheng; Chang, Jia-Kan; Lin, Chang-Chyi; Wu, Yong-Jian; Hsieh, Kai-Sheng

    2016-04-01

    On-site transthoracic echocardiography (TTE) to guide the transcutaneous closure of secundum-type atrial septal defects (ASDs) in the catheterization laboratory remains unclear, especially in adults. Between 2005 and 2012, a total of 82 adults underwent transcutaneous closure of ASDs. The initial 15 cases underwent the procedure with both on-site transesophageal echocardiography (TEE) and TTE monitoring. Since January 2008, a total of 67 patients underwent on-site TTE alone to guide the procedure. Among the 82 adult patients who underwent a transcutaneous closure of the secundum-type ASD procedure, all had successful closure of the defects, and no periprocedural adverse complications occurred. No statistical significance was observed in the successful complete shunt closure rate between the TEE plus TTE and TTE groups during sequential follow-up (postprocedure 24 hour [87% vs. 92%],1 month [93% vs. 95%], 3 month [93% vs. 97%], and 12 month [93% vs. 97%], P > 0.05, respectively) nor was a significant difference observed between the two groups, including decreased right ventricular dimension (29.5 ± 3.3 vs. 32.0 ± 4.9 mm, 26.5 ± 3.0 vs. 28.7 ± 4.6 mm, 26.2 ± 3.1 vs. 28.2 ± 4.8 mm, and 25.6 ± 2.8 vs. 27.7 ± 4.7 mm, P > 0.05, respectively) or increased left ventricular end-diastolic dimension (41.1 ± 2.0 vs. 42.6 ± 3.0 mm, 44.3 ± 2.7 vs. 45.5 ± 3.1 mm, 44.2 ± 2.8 vs. 45.4 ± 3.1 mm, 44.9 ± 2.7 vs. 45.8 ± 2.6 mm, P > 0.05, respectively) before the procedure, and at the 3-, 6-, and 12-month follow-up evaluations. This study showed that TTE guidance alone may be considered efficacious and safe as TEE during a transcutaneous ASD occlusion procedure in select adults. © 2015, Wiley Periodicals, Inc.

  10. Association of Dietary Factors with Progression of AA in Stroke/TIA Patients.

    PubMed

    Kodumuri, Nishanth; Giamberardino, Lauren; Hinderliter, Alan; Sen, Souvik

    2016-06-01

    To investigate the effect of dietary factors such as calorie intake and dietary fats on the progression of aortic arch atheroma (AA). In stroke/TIA patients, progression of AA is associated with recurrent vascular events. Consecutive patients with measurable (>1 mm) AA atheroma on baseline transesophageal echocardiogram (TEE) evaluation consented to a protocol mandated follow-up TEE at 12 months. Patients that had adequate paired AA images were assessed for progression, defined as Δ ≥ 1 grade worsening (based on plaque thickness over 12 months). Stroke risk factors and fasting lipid profile were assessed at baseline. The patient's nutritional intake was measured at baseline using the Gladys Block Food Frequency Questionnaire. One-hundred-nine patients (70 strokes, 33 TIAs) had sequential TEEs, of whom 27% (N=30) progressed and 73% (N=79) did not. Patients with progression had higher daily calorie (1778 ± 623 vs. 1378 ± 406 Calories, p=0.008), fat (76 ± 33 vs. 52 ± 23 grams, p=0.0002), carbohydrate (208 ± 78 vs. 169 ± 57 grams, p=0.01) and protein (73 ± 26 vs. 57 ± 21 grams, p=0.005) intake. On Further analysis among different fats showed a higher consumption of saturated fats (25 ± 12 vs. 17 ±8 grams, p=0.00051) as well as unsaturated fats (44 ± 20 vs. 30 ± 13 grams, p=0.002). These differences remained significant after we adjusted for the medication use. However the significance of these differences was attenuated after adjusting for the calorie intake. Cholesterol consumption did not differ between the progression and no-progression group (262 ± 125 vs. 213 ± 149 mg, p=0.2). Calorie intake plays a significant role in the progression of AA. Further studies are needed to confirm these findings and determine the specific dietary modifications that may prevent AA progression and associated recurrent vascular events.

  11. Energy expenditure and physical activity in Prader-Willi syndrome: comparison with obese subjects.

    PubMed

    Butler, Merlin G; Theodoro, Mariana F; Bittel, Douglas C; Donnelly, Joseph E

    2007-03-01

    Prader-Willi syndrome (PWS) is a complex neurodevelopmental disorder characterized by hypotonia, suck and feeding difficulties, hypogonadism, small hands and feet, developmental delay, hyperphagia and early childhood obesity and a particular facial appearance. The obesity associated with PWS is the result of a chronic imbalance between energy intake and energy expenditure (EE) due to hyperphagia, decreased physical activity, reduced metabolic rate and an inability to vomit. EE is affected by body composition as well as exercise. Individuals with PWS have a lower lean body mass (LBM) compared with controls which may contribute to reduced basal level EE. To determine the relationship among body composition, activity levels and metabolic rates, dual energy X-ray absorptiometry (DEXA) and a whole-room respiration chamber were used to measure body composition, total EE (TEE), resting EE (REE), physical activity, and mechanical work (MW) during an 8 hr monitoring period. The chamber consisted of a live-in whole-room indirect calorimeter equipped with a force platform floor to allow simultaneous measurement of EE, physical activity, and work efficiency during spontaneous activities and standardized exercise. Participants with PWS (27 with 15q11-q13 deletion and 21 with maternal disomy 15 with an average age of 23 years) had significantly decreased TEE by 20% and reduced LBM compared to 24 obese subjects. Similarly, REE was significantly reduced by 16% in the individuals with PWS relative to the comparison subjects. Total MW performed during the 8 hr monitoring period was significantly reduced by 35% in the PWS group. The energy cost of physical activity is related to the duration, intensity and type of activity and the metabolic efficiency of the individual. After adjusting group differences in LBM by analysis of variance, TEE and REE were no longer different between the two groups. Our data indicate that there is a significant reduction of EE in individuals with PWS

  12. Comparison of Echo and MRI in the Imaging Evaluation of Intracardiac Masses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulati, G., E-mail: gulatigurpreet@rediffmail.com; Sharma, S.; Kothari, S.S.

    We compared the efficacy of echocardiography (ECHO) and magnetic resonance imaging (MRI) for evaluating intracardiac masses. Over an 8-yr period, 28 patients, 21 males, 7 females, 16 days-60 years of age (mean 25 years) with a suspected intracardiac mass on ECHO (transthoracic in all; transesophageal in 9) underwent an MRI examination. Five patients had a contrast-enhanced MRI. ECHO and MRI were compared with respect to their technical adequacy, ability to detect and suggest the likely etiology of the mass, and provide additional information (masses not seen with the other technique, inflow or outflow obstruction, and intramural component of an intracavitarymore » mass). With MRI, the image morphology (including signal intensity changes on the various sequences) and extracardiac manifestations were also evaluated. The diagnosis was confirmed by histopathology in 18, surgical inspection in 4, by follow- up imaging on conservative management in 5, and by typical extracardiac manifestations of the disease in 1 patient.Fifteen (54%) patients had tumors (benign 12, malignant 3), 5 had a thrombus or hematoma, and 4 each had infective or vascular lesions. Thirty-four masses (13 in ventricle, 11 septal, 7 atrial, 2 on valve and 1 in pulmonary artery) were seen on MRI, 28 of which were detected by ECHO. Transthoracic ECHO (TTE) and MRI were technically optimal in 82% and 100% of cases, respectively. Nine patients needed an additional transesophageal ECHO (TEE). Overall, MRI showed a mass in all patients, whereas ECHO missed it in 2 cases. In cases with a mass on both modalities, MRI detected 4 additional masses not seen on ECHO. MRI suggested the etiology in 21 (75%) cases, while the same was possible with ECHO (TTE and TEE) in 8 (29%) cases. Intramural component, extension into the inflow or outflow, outflow tract obstruction, and associated pericardial or extracardiac masses were better depicted on MRI. We conclude that MRI is advantageous over a combination of TTE and

  13. Activity energy expenditure and change in body composition in late life123

    PubMed Central

    Everhart, James E; Anton, Stephen D; Schoeller, Dale A; Cummings, Steve R; Mackey, Dawn C; Delmonico, Matthew J; Bauer, Douglas C; Simonsick, Eleanor M; Colbert, Lisa H; Visser, Marjolein; Tylavsky, Frances; Newman, Anne B; Harris, Tamara B

    2009-01-01

    Background: Change in body composition, specifically loss of fat-free mass and gain in fat mass, in older adults is a major pathway leading to the onset of functional decline and physical disability. Objective: The objective was to determine the association of activity-related energy expenditure with change in body mass and composition among older men and women. Design: Total energy expenditure (TEE) was assessed over 2 wk by using the doubly labeled water method in 302 community-dwelling older adults aged 70–82 y. Resting metabolic rate (RMR) was measured by using indirect calorimetry, and the thermic effect of meals was estimated at 10% of TEE. Activity energy expenditure (AEE) was calculated as [TEE(0.9) − RMR]. Total body mass, fat-free mass (FFM), and fat mass (FM) were assessed by dual-energy X-ray absorptiometry annually over a mean (±SD) of 4.9 ± 1.3 y. Results: In multivariate models adjusted for baseline age, smoking status, and race, men and women had a decline (in kg/y) in body mass (men: −0.34, 95% CI: −0.71, 0.02; women: −0.45, 95% CI: −0.71, −0.19) and FFM (men: −0.48, 95% CI: −0.67, −0.29; women: −0.14, 95% CI: −0.026, −0.03). No changes (in kg/y) were observed in FM (men: 0.14, 95% CI: −0.10, 0.38; women: −0.28, 95% CI: −0.49, −0.07). In men and women, higher AEE at baseline was associated with greater FFM. The average change in these outcomes (ie, slope), however, was similar across tertiles of AEE. Conclusions: These data suggest that accumulated energy expenditure from all physical activities is associated with greater FFM, but the effect does not alter the trajectory of FFM change in late life. PMID:19740971

  14. Endothelial dysfunction is an independent risk factor for stroke patients irrespective of the presence of patent foramen ovale.

    PubMed

    Sunbul, M; Ozben, B; Durmus, E; Kepez, A; Pehlivan, A; Midi, I; Mutlu, B

    2013-09-01

    Paradoxical embolization through the patent foramen ovale (PFO) is the major cause of most cryptogenic stroke cases. However, the presence of PFO may simply be an incidental finding in these patients, and endothelial dysfunction may be the underlying reason of ischemic stroke. The aim of this study was to compare the endothelial function of cryptogenic stroke patients according to the presence of PFO. Sixty consecutive patients with cryptogenic stroke referred for transesophageal echocardiography (TEE) and 39 consecutive nonstroke patients referred for TEE examination because of suspected PFO were included in the study. Endothelial functions were assessed by brachial artery ultrasonography. PFO was diagnosed by the presence of right-to-left passage of contrast bubbles during TEE. Stroke and nonstroke patients were further subdivided into two groups according to the presence of PFO. Stroke patients had significantly lower flow-mediated dilation (FMD) values than nonstroke patients (8.36 ± 4.38 % vs. 12.57 ± 4.90 %, p < 0.001). The stroke patients with PFO had significantly lower FMD measures than nonstroke patients with PFO (6.60 ± 3.98 % vs. 10.84 ± 4.40 %, p = 0.001). Similarly, cryptogenic stroke patients without PFO had significantly lower FMD measures than nonstroke patients without PFO (9.90 ± 4.18 % vs. 14.22 ± 4.88, p = 0.002). Logistic regression analysis showed FMD as an independent predictor of cryptogenic stroke when adjusted by age, sex, and presence of PFO (odds ratio: 0.809, 95 % confidence interval: 0.719-0.911, p < 0.001). An FMD value of  11.30 % or lower predicted cryptogenic stroke with a sensitivity of 78.3 %, a specificity of 66.7 %, and positive and negative predictive values of 78.3 and 66.7 %, respectively. Endothelial dysfunction seems to play a more important role than PFO in the underlying mechanism of cryptogenic stroke.

  15. A Framework for Implementing a CSCW Environment to Improve Product Development Decision-Making

    DTIC Science & Technology

    2007-01-01

    Program* Crwsonmenujl Trucks / Pemonrel Tee Bads / Dnvatraln oaof Corcepa / Robotics Soecflc Programs / SurvrvabsHy Hybrids / SpecHM...paper, dated June 2005 This paper was prepared for the 6th International All Electric Combat Veicle Conference 13- 16 June 2005 Related to power...issues faced by hybrid and fuel cell vehicles No Table 5.6 Results from Run VI Analysis of Case Study I The results of the six runs provided an

  16. Translations on Eastern Europe Political, Sociological, and Military Affairs, Number 1330

    DTIC Science & Technology

    1976-12-06

    of these raw materials would be established by a joint commission with headquarters in Budapest ; and the above-mentioned states would "guaran- tee...nations that had /never/ been consulted when the governments in Budapest or Vienna decided their fate, when the territo- ries that legitimately...nationalities and to exploit the industrial and agricultural resources of central Europe for the benefit of Budapest and a certain number of owners

  17. A Hybrid Approach to Composite Damage and Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics

    DTIC Science & Technology

    2017-03-30

    Composite Damage and Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics 5b. GRANT NUMBER NOOO 14-16-1-21 73 5c. PROGRAM...ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Texas A&M Engineering Experiment Station (TEES) 400 Harvey Mitchell Parkway, Suite 300 M160 1473 I...Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics Award Number N00014-16-1-2173 DOD-NAVY- Office of Naval Research PI: Ramesh

  18. A Hybrid Approach to Composite Damage and Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics

    DTIC Science & Technology

    2016-06-30

    PERFORMING ORGANIZATION Texas A&M Eng ineering Experiment Station (TEES) REPORT NUMBER 1470 William D. Fitch Parkway M1601473/ 505170-00001/2...0.7% strain when the dilatational energy density reaches the experimentally determined critical value (0.2 MPa). 3 To validate whether the critical...implementation against experimental results in terms of the crack path shape. We perform convergence studies in terms of the non local region size for

  19. 6. INTERIOR VIEW OF BASEMENT OF CA. 1948 FACTORY ADDITION, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. INTERIOR VIEW OF BASEMENT OF CA. 1948 FACTORY ADDITION, WITH REINFORCED CONCRETE FRAME AND FLOOR OF REINFORCED CONCRETE TEE-BEAMS, LOOKING NORTH. AT LEFT IS DEEP DRAW, HEAVY PRESS MANUFACTURED BY E. W. BLISS CO., BROOKLYN, NEW YORK. PRESS #3-1/2 B, PATENTED BY E. W. BLISS CO., 1893. MANUFACTURERS PLATE INDICATES PRESS DATES FROM 1920. - Illinois Pure Aluminum Company, 109 Holmes Street, Lemont, Cook County, IL

  20. Benzocaine-induced methaemoglobinaemia: a life-threatening complication after a transoesophageal echocardiogram (TEE)

    PubMed Central

    Aryal, Madan Raj; Gupta, Shobhit; Giri, Smith; Diaz Fraga, Julian

    2013-01-01

    Acquired methaemoglobinaemia is a potentially fatal impairment in oxygen delivery if not recognised early and treated appropriately. Benzocaine used as an anaesthetic for endoscopic procedures is an uncommon but clinically important precipitant of acquired methaemoglobinaemia. We present a case of an elderly woman who developed perioral cyanosis and desaturation 20 min after a transoesophageal echocardiogram. Further evaluation led to the diagnosis of benzocaine-induced methaemoglobinaemia and timely treatment with intravenous methylene blue was initiated. PMID:24042203

  1. Benzocaine-induced methaemoglobinaemia: a life-threatening complication after a transoesophageal echocardiogram (TEE).

    PubMed

    Aryal, Madan Raj; Gupta, Shobhit; Giri, Smith; Fraga, Julian Diaz

    2013-09-16

    Acquired methaemoglobinaemia is a potentially fatal impairment in oxygen delivery if not recognised early and treated appropriately. Benzocaine used as an anaesthetic for endoscopic procedures is an uncommon but clinically important precipitant of acquired methaemoglobinaemia. We present a case of an elderly woman who developed perioral cyanosis and desaturation 20 min after a transoesophageal echocardiogram. Further evaluation led to the diagnosis of benzocaine-induced methaemoglobinaemia and timely treatment with intravenous methylene blue was initiated.

  2. Modeling interfacial area transport in multi-fluid systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yarbro, Stephen Lee

    1996-11-01

    Many typical chemical engineering operations are multi-fluid systems. They are carried out in distillation columns (vapor/liquid), liquid-liquid contactors (liquid/liquid) and other similar devices. An important parameter is interfacial area concentration, which determines the rate of interfluid heat, mass and momentum transfer and ultimately, the overall performance of the equipment. In many cases, the models for determining interfacial area concentration are empirical and can only describe the cases for which there is experimental data. In an effort to understand multiphase reactors and the mixing process better, a multi-fluid model has been developed as part of a research effort to calculate interfacialmore » area transport in several different types of in-line static mixers. For this work, the ensemble-averaged property conservation equations have been derived for each fluid and for the mixture. These equations were then combined to derive a transport equation for the interfacial area concentration. The final, one-dimensional model was compared to interfacial area concentration data from two sizes of Kenics in-line mixer, two sizes of concurrent jet and a Tee mixer. In all cases, the calculated and experimental data compared well with the highest scatter being with the Tee mixer comparison.« less

  3. A Case of Shunting Postoperative Patent Foramen Ovale Under Mechanical Ventilation Controlled by Different Ventilator Settings.

    PubMed

    Pragliola, Claudio; Di Michele, Sara; Galzerano, Domenico

    2017-06-07

    A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H 2 O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H 2 O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  4. Ultrasound based mitral valve annulus tracking for off-pump beating heart mitral valve repair

    NASA Astrophysics Data System (ADS)

    Li, Feng P.; Rajchl, Martin; Moore, John; Peters, Terry M.

    2014-03-01

    Mitral regurgitation (MR) occurs when the mitral valve cannot close properly during systole. The NeoChordtool aims to repair MR by implanting artificial chordae tendineae on flail leaflets inside the beating heart, without a cardiopulmonary bypass. Image guidance is crucial for such a procedure due to the lack of direct vision of the targets or instruments. While this procedure is currently guided solely by transesophageal echocardiography (TEE), our previous work has demonstrated that guidance safety and efficiency can be significantly improved by employing augmented virtuality to provide virtual presentation of mitral valve annulus (MVA) and tools integrated with real time ultrasound image data. However, real-time mitral annulus tracking remains a challenge. In this paper, we describe an image-based approach to rapidly track MVA points on 2D/biplane TEE images. This approach is composed of two components: an image-based phasing component identifying images at optimal cardiac phases for tracking, and a registration component updating the coordinates of MVA points. Preliminary validation has been performed on porcine data with an average difference between manually and automatically identified MVA points of 2.5mm. Using a parallelized implementation, this approach is able to track the mitral valve at up to 10 images per second.

  5. Validation of an Online Food Frequency Questionnaire against Doubly Labelled Water and 24 h Dietary Recalls in Pre-School Children

    PubMed Central

    Delisle Nyström, Christine; Henriksson, Hanna; Alexandrou, Christina; Bergström, Anna; Bonn, Stephanie; Bälter, Katarina; Löf, Marie

    2017-01-01

    The development of easy-to-use and accurate methods to assess the intake of energy, foods and nutrients in pre-school children is needed. KidMeal-Q is an online food frequency questionnaire developed for the LifeGene prospective cohort study in Sweden. The aims of this study were to compare: (i) energy intake (EI) obtained using KidMeal-Q to total energy expenditure (TEE) measured via doubly labelled water and (ii) the intake of certain foods measured using KidMeal-Q to intakes acquired by means of 24 h dietary recalls in 38 children aged 5.5 years. The mean EI calculated using KidMeal-Q was statistically different (p < 0.001) from TEE (4670 ± 1430 kJ/24 h and 6070 ± 690 kJ/24 h, respectively). Significant correlations were observed for vegetables, fruit juice and candy between KidMeal-Q and 24 h dietary recalls. Only sweetened beverage consumption was significantly different in mean intake (p < 0.001), as measured by KidMeal-Q and 24 h dietary recalls. In conclusion, KidMeal-Q had a relatively short answering time and comparative validity to other food frequency questionnaires. However, its accuracy needs to be improved before it can be used in studies in pre-school children. PMID:28098765

  6. Validation of an Online Food Frequency Questionnaire against Doubly Labelled Water and 24 h Dietary Recalls in Pre-School Children.

    PubMed

    Delisle Nyström, Christine; Henriksson, Hanna; Alexandrou, Christina; Bergström, Anna; Bonn, Stephanie; Bälter, Katarina; Löf, Marie

    2017-01-13

    The development of easy-to-use and accurate methods to assess the intake of energy, foods and nutrients in pre-school children is needed. KidMeal-Q is an online food frequency questionnaire developed for the LifeGene prospective cohort study in Sweden. The aims of this study were to compare: (i) energy intake (EI) obtained using KidMeal-Q to total energy expenditure (TEE) measured via doubly labelled water and (ii) the intake of certain foods measured using KidMeal-Q to intakes acquired by means of 24 h dietary recalls in 38 children aged 5.5 years. The mean EI calculated using KidMeal-Q was statistically different ( p < 0.001) from TEE (4670 ± 1430 kJ/24 h and 6070 ± 690 kJ/24 h, respectively). Significant correlations were observed for vegetables, fruit juice and candy between KidMeal-Q and 24 h dietary recalls. Only sweetened beverage consumption was significantly different in mean intake ( p < 0.001), as measured by KidMeal-Q and 24 h dietary recalls. In conclusion, KidMeal-Q had a relatively short answering time and comparative validity to other food frequency questionnaires. However, its accuracy needs to be improved before it can be used in studies in pre-school children.

  7. An easy-to-use semiquantitative food record validated for energy intake by using doubly labelled water technique.

    PubMed

    Koebnick, C; Wagner, K; Thielecke, F; Dieter, G; Höhne, A; Franke, A; Garcia, A L; Meyer, H; Hoffmann, I; Leitzmann, P; Trippo, U; Zunft, H J F

    2005-09-01

    Estimating dietary intake is important for both epidemiological and clinical studies, but often lacks accuracy. To investigate the accuracy and validity of energy intake estimated by an easy-to-use semiquantitative food record (EI(SQFR)) compared to total energy expenditure (TEE) estimated by doubly labelled water technique (EE(DLW)). TEE was measured in 29 nonobese subjects using the doubly labelled water method over a period of 14 days. Within this period, subjects reported their food consumption by a newly developed semiquantitative food record for 4 consecutive days. Energy intake was calculated using the German Food Code and Nutrition Data Base BLS II.3. A good correlation was observed between EI(SQFR) and EE(DLW) (r = 0.685, P < 0.001). The mean difference between EI(SQFR) and EE(DLW) was -1.7+/-2.6 MJ/day (-14+/-21%, P = 0.002). An underestimation of EI(SQFR) <10% was observed in nine subjects (31%), of 10-20% in six subjects (21%), and of >20% in nine subjects (31%). In five subjects (17%), an overestimation of EI(SQFR) was observed. The easy-to-use semiquantitative food record provided good estimates of EI in free-living and nonobese adults without prior detailed verbal instructions. The presented food record has limitations regarding accuracy at the individual level.

  8. Effects of Gender, Load, and Backpack on the Temporal and Kinematic Characteristics of Walking Gait. Volume 3

    DTIC Science & Technology

    1982-04-01

    TEeHNICAt LIBRARY U.S. ARMY NATICK R & Q LABORAIOltlfJ NATICK, MA 01760 BY PWLIP E. MARTIN AND RICHARD C. NELSON BIOMECHANICS LABORATORY THE...ELEMENT, PROJECT, TASK AREA & WORK UNIT NUMBERS Biomechanics Laboratory 62, 9p05 The Pennsylvania State University 6.2 University Park, Pennsylvania 16802...SUMMARY AND RECOMMENDATIONS 37 3 TABLE OF CONTENTS (continued) Page REFERENCES 39 APPENDICES A. Clothing and Equipment Used in This Study 41 B. ANOVA

  9. Effects of Trade Restrictions on Imports of Steel.

    DTIC Science & Technology

    1980-11-01

    Biemh g 9tee). 626-55 an Innovation ." Tire steps. The first is to derive desired employment. We Quarterly Journal ot Econonum3 s, o (May 1966). 167...the presence of trade (te. 1973. Washington. D.C , 1974. restrictions. To derive desired employment without 4. Armington. Paul S. -A Theory of Demand...papers are available from th Management Information Office Centr for Naval Anallysea 2000 North Bluregard Street, Alexarndria. Virginia 22311. An Index

  10. An Analysis of the President’s 2013 Budget

    DTIC Science & Technology

    2012-03-01

    and incorporates estimates by the staff of the Joint Commit- tee on Taxation for the President’s tax proposals.1 In conjunction with analyzing the...such debt would decline to 61 percent by the end of 2022.1. For more details about the President’s revenue proposals, see Joint Committee on Taxation ...the President’s Budget (Billions of dollars) Sources: Congressional Budget Office; Staff of the Joint Committee on Taxation . Note: n.a. = not

  11. JPRS Report, East Europe

    DTIC Science & Technology

    1987-10-19

    Committee and head of the committee’s Foreign Affairs Department, and Medgyessy Peter, member of the party Central Commit- tee and head of the...vice-premier, and Zhu Liang, head of the International Liaison Department of the CPC Cen- tral Committee. A formal welcoming ceremony is scheduled...forthcoming party congress he will resign even as head of the Central Advisory Commission, the body consisting of elderly politicians. He would then only

  12. Vegetation and Environmental Gradients of the Prudhoe Bay Region, Alaska,

    DTIC Science & Technology

    1985-09-01

    to patterned-ground features , gram (IBP) to examine the tundra biome (Brown and the effects on other soil parameters. A major 1975, Tieszen 1978...ment of Environmental, Population and Organismic Biology. The study was initiat- ed in 1973 under the U.S. Tundra Biome portion of the International...contributions to the University of Alaska’s Tundra Biome Center from the Prudhoe Bay Environmental Subcommit- tee of the Alaska Oil and Gas Association

  13. JPRS Report, East Europe

    DTIC Science & Technology

    1988-01-19

    87 p6 [PAP report from Bejing : "OPZZ Delegation Received by the Acting Secretary General of the Central Commit- tee of the Communist Party of China ...With China Viewed Favorably [TRYBUNA LUDU, 19 Oct 87] 34 Publication Cooperation Talks With Italians [TRYBUNA LUDU, 12 Oct 87] 35 Agriculture...consider what is happening elsewhere, in the USSR and in China . And what how are the Hungarians responding? Should Poland lag behind in its treatment

  14. Direct Filling Golds: An In-Vitro Study of Microleakage as a Function of Condensation Force: An In-Vivo Study of Marginal Quality

    DTIC Science & Technology

    1979-01-01

    three teeth in vivo in dogs . All three showed penetration surrounding the restorations. No mention was made as to whether a cavity varnish was...gingival reactions to gold foil restorations. J Periodontal 46:614, 1975. 12. Christensen, C.J.: -iologic implications of dental restorations. J -m Acad...1ack, C.17.: An investignr-ian of the physical characters of thle huna. tee--: in relation to their diseases and to practical dental o-ierations

  15. Department of Defense DOD Freedom of Information Act Program

    DTIC Science & Technology

    1998-09-01

    Enter year. month. end d",r La .. 19971024, the tee nmwa.payeynit was receive. r,. PKIOFISSIOAL HOURS. For each applIcabl activity Toot Collsotabl Cosas ...through the Federal Register, the National Technical Information Service, or the Internet , normally need not be processed under the provisions of the FOIA...court shall evaluate the case de novo (anew) and may elect to examine any requested record in camera (in private) to determine whether the denial was

  16. Sharing Power? Prospects for a U.S. Concert-Balance Strategy

    DTIC Science & Technology

    2013-04-01

    Regional strategic appraisals; • The nature of land warfare; • Matters affecting the Army’s future; • The concepts , philosophy, and theory of strategy...and long-term consequences. To strategize is to relativize . Through the lens of grand strategy, what seems like a bad military failure or...allies have long done). It car- 12 ries the “ moral hazard” problem of unintentionally underwriting the risky behavior of others by guaran- teeing their

  17. A Hybrid Approach to Composite Damage and Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics

    DTIC Science & Technology

    2016-12-31

    PERFORMING ORGANIZATION REPORT NUMBER Texas A&M Engineering Experiment Station (TEES) 400 Harvey Mitchell Parkway, Suite 300 M1601473 I 505170-0000112...likely to influence the quasi -static and dynamic crack growth in the composite system. For this step we need a method that reduces/eliminates stress...1 0 7 0 E 0 E _, - 5 _, Fig. 2.1. Quasi -static stretching of an elastic material. Bottom row shows the horizontal displacement obtained with

  18. International Workshop on Millimeter Waves (1992) Held in Orvieto, Italy on April 22-24, 1992

    DTIC Science & Technology

    1992-04-24

    1fillinmler4Vtlatri Circuits T. Yotwymatiat. Receott IDeehotnns. #of NRI)-;,.,s. Te, impIig It. 11. Jamset. Adv’anced Design Tee hnu jues fir Leiear... designed for the sky radiation measurement. - consideration of typical flight altitudes of 300m to Its output delivers a mean-value of the relevant...Electrolytic Processes: Anodic, Etching and Cathodic -increase of Surface to Volume Ratio metal deponition. Loca-Stuctre epoitin b pont- ikea ) no damage

  19. Antithrombotic therapy in atrial fibrillation: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition).

    PubMed

    Singer, Daniel E; Albers, Gregory W; Dalen, James E; Fang, Margaret C; Go, Alan S; Halperin, Jonathan L; Lip, Gregory Y H; Manning, Warren J

    2008-06-01

    /d (Grade 1B), because of their low risk of ischemic stroke. For patients with atrial flutter, we recommend that antithrombotic therapy decisions follow the same risk-based recommendations as for AF (Grade 1C). For patients with AF and mitral stenosis, we recommend long-term anticoagulation with an oral VKA (Grade 1B). For patients with AF and prosthetic heart valves we recommend long-term anticoagulation with an oral VKA at an intensity appropriate for the specific type of prosthesis (Grade 1B). See CHEST 2008; 133(suppl):593S-629S. For patients with AF of > or =48 h or of unknown duration for whom pharmacologic or electrical cardioversion is planned, we recommend anticoagulation with an oral VKA, such as warfarin, for 3 weeks before elective cardioversion and for at least 4 weeks after sinus rhythm has been maintained (Grade 1C). For patients with AF of > or = 48 h or of unknown duration undergoing pharmacological or electrical cardioversion, we also recommend either immediate anticoagulation with unfractionated IV heparin, or low-molecular-weight heparin (LMWH), or at least 5 days of warfarin by the time of cardioversion (achieving an INR of 2.0-3.0) as well as a screening multiplane transesophageal echocardiography (TEE). If no thrombus is seen, cardioversion is successful, and sinus rhythm is maintained, we recommend anticoagulation for at least 4 weeks. If a thrombus is seen on TEE, then cardioversion should be postponed and anticoagulation should be continued indefinitely. We recommend obtaining a repeat TEE before attempting later cardioversion (Grade 1B addressing the equivalence of TEE-guided vs non-TEE-guided cardioversion). For patients with AF of known duration <48 h, we suggest cardioversion without prolonged anticoagulation (Grade 2C). However, in patients without contraindications to anticoagulation, we suggest beginning IV heparin or LMWH at presentation (Grade 2C).

  20. The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine.

    PubMed

    Liu, Peng; Liu, Rijing; Zhang, Yan; Liu, Yingfeng; Tang, Xiaoming; Cheng, Yanzhen

    The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion. Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored. Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion. We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the

  1. Surveying predictors of late-life longitudinal change in daily activity energy expenditure.

    PubMed

    Valiani, Vincenzo; Sourdet, Sandrine; Schoeller, Dale A; Mackey, Dawn C; Bauer, Douglas C; Glynn, Nancy W; Yamada, Yosuke; Harris, Tamara B; Manini, Todd M

    2017-01-01

    Total daily energy expenditure (TEE) is composed of resting metabolic rate (RMR), post-prandial thermogenesis and activity energy expenditure (AEE). Higher AEE is strongly associated with lower mortality and physical limitations among older adults, but factors that predict changes in AEE in septu and octogenarians are not clearly understood. To identify factors associated with late-life longitudinal change in AEE. Energy expenditure was re-assessed in 83 participants (average age at baseline, 74.4±3.2 years)-an average of 7.5±0.54 years since the baseline measure. RMR was measured using indirect calorimetry and the thermic effect of meals was estimated at 10% of TEE. AEE was calculated as: TEE(0.9)-RMR. Participants were categorized into two groups according to the estimated day-to-day precision of the doubly-labeled water technique. Those who were within 10% or increased relative to their initial AEE measurement were categorized as having preserved AEE. Participants who declined greater than 10% of their initial measurement were categorized as having reduced AEE. A variety of socio-demographic, functional and mental factors, body composition, community and personal behaviors, blood measurements and health conditions were evaluated between groups at baseline and changes during follow-up. Daily AEE declined 106.61±293.25 kcal, which equated to a 14.63±40.57 kcal/d decrease per year. Fifty-nine percent (n = 49) preserved their AEE and 41% (n = 34) declined. Those who demonstrated a decline in AEE were older, had lower walking speed at baseline and showed a higher lean mass loss during follow up. Otherwise, groups were similar for socio-demographic characteristics, body composition, mental and physical function, health conditions and community and personal behaviors at baseline and change in these factors during follow-up. This study demonstrates that AEE declines through the 8th decade of life and is associated with age, lower walking speed at baseline and lean

  2. Prior automatic posture and activity identification improves physical activity energy expenditure prediction from hip-worn triaxial accelerometry.

    PubMed

    Garnotel, M; Bastian, T; Romero-Ugalde, H M; Maire, A; Dugas, J; Zahariev, A; Doron, M; Jallon, P; Charpentier, G; Franc, S; Blanc, S; Bonnet, S; Simon, C

    2018-03-01

    Accelerometry is increasingly used to quantify physical activity (PA) and related energy expenditure (EE). Linear regression models designed to derive PAEE from accelerometry-counts have shown their limits, mostly due to the lack of consideration of the nature of activities performed. Here we tested whether a model coupling an automatic activity/posture recognition (AAR) algorithm with an activity-specific count-based model, developed in 61 subjects in laboratory conditions, improved PAEE and total EE (TEE) predictions from a hip-worn triaxial-accelerometer (ActigraphGT3X+) in free-living conditions. Data from two independent subject groups of varying body mass index and age were considered: 20 subjects engaged in a 3-h urban-circuit, with activity-by-activity reference PAEE from combined heart-rate and accelerometry monitoring (Actiheart); and 56 subjects involved in a 14-day trial, with PAEE and TEE measured using the doubly-labeled water method. PAEE was estimated from accelerometry using the activity-specific model coupled to the AAR algorithm (AAR model), a simple linear model (SLM), and equations provided by the companion-software of used activity-devices (Freedson and Actiheart models). AAR-model predictions were in closer agreement with selected references than those from other count-based models, both for PAEE during the urban-circuit (RMSE = 6.19 vs 7.90 for SLM and 9.62 kJ/min for Freedson) and for EE over the 14-day trial, reaching Actiheart performances in the latter (PAEE: RMSE = 0.93 vs. 1.53 for SLM, 1.43 for Freedson, 0.91 MJ/day for Actiheart; TEE: RMSE = 1.05 vs. 1.57 for SLM, 1.70 for Freedson, 0.95 MJ/day for Actiheart). Overall, the AAR model resulted in a 43% increase of daily PAEE variance explained by accelerometry predictions. NEW & NOTEWORTHY Although triaxial accelerometry is widely used in free-living conditions to assess the impact of physical activity energy expenditure (PAEE) on health, its precision and accuracy are often debated

  3. JPRS Report, Soviet Union, Political Affairs

    DTIC Science & Technology

    1988-11-16

    present article makes an attempt to examine the essence and main content of the new political thinking on the nationality question and also certain...Communist Party Central Commit- tee’s Institute of Party History N.S.Stashkevich, Ph.D. in History. The essence of his thought is that the life and career...they were crystal clear. The essence of the highest truth is to give a person his due according to his true merits, deeds and actions, while

  4. Proceedings of the twentieth annual meeting of the society for organic petrology

    USGS Publications Warehouse

    Bragg, Linda J.; Lentz, Erika E.; Warwick, Peter D.; Finkelman, Robert B.; Trippi, Michael H.; Karlsen, Alex W.

    2004-01-01

    The Society for Organic Petrology (TSOP; pronounced "Tee'-sop") was established in 1984 to consolidate and foster the organizational activities of scientists and engineers involved with coal petrology, kerogen petrology, organic geochemistry, and related disciplines. The following report, "Proceedings of the Twentieth Annual Meeting of The Society for Organic Petrology" (ISSN 1060-7250), features technical talks, poster presentations, business meetings, short courses, and field trips from the Fall 2003 annual meeting held in Washington, D.C.

  5. Battle Group Asset Management Decision Support System.

    DTIC Science & Technology

    1984-03-01

    3.141 Terminal Display - Battle Group Missile Sys . 202 3.142 Battle Group Gun Systems . . . . . . . . . . . 204 3.143 Force missile and Gun Systems...with the sys -.6e, and/or the battle group has nct, as yet, been 61 * (MAIN MENU CC¢TI.) * SENSCR --- GRAPHICALLY DISPLAY UNIT/FORCE SENSCR *COVERAGE...BUILD A DATABASE OF THE CAPABILITIES OF THE UNITS IN YOUR BATTLE GROUP. THESE I CAPAEILITIES WILL INCLUDE ALL SENSOR AND WEAPONS SYS - TEES CNBCARD, AS

  6. JPRS Report, Soviet Union, Political Affairs, Preparations for the 19th Party Conference, Part 4.

    DTIC Science & Technology

    1988-10-30

    the works of V.l. Lenin and party documents of the Leninist period. Then the requirements of glasnost and their practical realization during the... during the precongress discus- sion, the sketch from Tula Oblast entitled "Restoration," etc. Letters have been published in the newspaper from those on...level, during the regular report-election campaign in the party. Discussion of the Theses of the CPSU Central Commit- tee for the 19th All-Union Party

  7. Marriage/Family Issues and Wife Styles Across Naval Officer Career Stages: Their Implications for Career Success

    DTIC Science & Technology

    1979-05-01

    Drr N600 -79-C-314 9. PERFORMING ORGANIZATION NAME AIADDRESS 10. PROGRAM ELEMENT. PROJECT, TASK Naval Postgraduate School NRi7O-836 , 61153N Monterey...the various career stages, and whether/how organizational politics played a role in career satisfaction and productivity. The purpose of this paper is... Satisfaction (tee Item D, Part B, Appendix B) reported a relative sense of well-being. Table 4 below reports the average scores for sixteen wives responding to

  8. Structured Analysis for the Logistic Support Analysis (LSA) Task and the Integrated Logistic Support (ILS) Element. Structured Analysis - ILS Assessment Element E11. Design Influence

    DTIC Science & Technology

    1989-01-01

    format size of this report, the full identifying entry may well be forcibly shortened, thereby introducing the possibility of misunderstanding. Therefore...OF MATERIEL" 3d . "AR 570-9, "MANPOWER AND EQUIPMENT CONTROL - HOST NATION SUPPORT" 2. AR 700-9, "POLICIES OF THE ARMY LOGISTIC SYSTEM" 3. AR 700-82...PERSONNEL 4. TRAINING 5. SYSTEM SAFETY 6. HEALTH HAZARDS. TEE ASSESSMENT Or MANPRINT INFLUENCE ON DESIGNS IS ADDRESSED IN SIX (6) SPECIFIC AREAS IN

  9. Reduced Gravity Gas and Liquid Flows: Simple Data for Complex Problems

    NASA Technical Reports Server (NTRS)

    McQuillen, John; Motil, Brian

    2001-01-01

    While there have been many studies for two-phase flow through straight cylindrical tubes, more recently, a new group of studies have emerged that examine two-phase flow through non-straight, non-cylindrical geometries, including expansions, contractions, tees, packed beds and cyclonic separation devices. Although these studies are still, relatively speaking, in their infancy, they have provided valuable information regarding the importance of the flow momentum, and the existence of liquid dryout due to sharp comers in microgravity.

  10. Mean platelet volume is elevated in patients with patent foramen ovale.

    PubMed

    Demir, Bulent; Caglar, Ilker Murat; Ungan, Ismail; Ugurlucan, Murat; Tureli, Hande Oktay; Karakaya, Osman

    2013-12-30

    Platelets play a major role in thromboembolic events. Increased mean platelet volume (MPV) indicates higher platelet reactivity and also a tendency to thrombosis. Patent foramen ovale (PFO), persistence of the fetal anatomic shunt between right and left atria, is strongly associated with cryptogenic stroke. The aim of this study is to determine the relationship between MPV and PFO and if such an association exists, whether higher MPV levels may require antiplatelet therapy before a thromboembolic event happens, together with a literature review. Thirty patients (15 women, 15 men), free of any cerebrovascular events, were diagnosed with PFO by transesophageal echocardiography (TEE), enrolled as the study group. Thirty consecutive patients (16 women and 14 men), who were diagnosed as normal in TEE, were enrolled as the control group. These two groups were compared according to MPV and anatomical features of the right atrium. There was no significant difference between study and control groups in clinical features and also no difference was observed in platelet counts; however, MPV in the PFO group was significantly higher than the control group (8.38 ±0.93 fl and 7.45 ±0.68 fl respectively). Our results indicate that elevated MPV may be detected in patients with PFO. This might be one of the explanations for the relationship between PFO and cryptogenic stroke; however, larger cohorts are warranted in order to define further mechanisms.

  11. Validation of the VERT wearable jump monitor device in elite youth volleyball players

    PubMed Central

    Borges, Thiago O.; Moreira, Alexandre; Bacchi, Renato; Finotti1, Ronaldo L.; Ramos, Mayara; Lopes, Charles R.

    2017-01-01

    This technical report aims to determine the validity and the accuracy of the VERT Wearable Jump Monitor. The participants of this study were all experienced volleyball players from the U18 category from the Brazilian National team. To assess jump performance, the VERT scores were compared to the VERTEC (jump and reach device). Each athlete performed 3 attack and 3 block jumps in a random, counterbalanced order, and the average score was registered. In the attack jumps, the VERTEC and VERT mean ± SD scores were 70.9±8.2 and 76.3±7.5 cm, respectively, and the typical error of the estimate (TEE) as a coefficient of variation (CV) was 7.8% (90% CL 7.0 to 8.9%). VERTEC and VERT devices presented a very large Pearson’s correlation for attack jumps (r=0.75; 90% CL 0.68 to 0.81). In addition, the mean±SD block jumps were 53.7±6.1 and 58.5±5.7 cm for the VERTEC and VERT, respectively and the TEE as a CV was 7.9% (90% CL 7.1 to 8.9%). Pearson’s correlation coefficient was very large for block jumps (r=0.75; 90% CL 0.67 to 0.81). The VERT device was found to be a very practical tool to quantify jump performance in volleyball players. PMID:29158616

  12. Role of modern 3D echocardiography in valvular heart disease

    PubMed Central

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  13. Design of a Matrix Transducer for Three-Dimensional Second Harmonic Transesophageal Echocardiography

    NASA Astrophysics Data System (ADS)

    Blaak, Sandra; van Neer, Paul L. M. J.; Prins, Christian; Bosch, Johan G.; Lancée, Charles T.; van der Steen, Antonius F. W.; de Jong, Nico

    Three-dimensional (3D) echocardiography visualizes the 3D anatomy and function of the heart. For 3D imaging an ultrasound matrix of several thousands of elements is required. To connect the matrix to an external imaging system, smart signal processing with integrated circuitry in the tip of the TEE probe is required for channel reduction. To separate the low voltage integrated receive circuitry from the high voltages required for transmission, our design features a separate transmit and receive subarray. In this study we focus on the transmit subarray. A 3D model of an individual element was developed using the finite element method (FEM). The model was validated by laser interferometer and acoustic measurements. Measurement and simulations matched well. The maximum transmit transfer was 3 nm/V at 2.4 MHz for both the FEM simulation of an element in air and the laser interferometer measurement. The FEM simulation of an element in water resulted in a maximum transfer of 43 kPa/V at 2.3 MHz and the acoustic measurement in 55 kPa/V at 2.5 MHz. The maximum pressure is ~1 MPa/120Vpp, which is sufficient pressure for second harmonic imaging. The proposed design of the transmit subarray is suitable for its role in a 3D 2H TEE probe.

  14. Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

    PubMed

    Basman, Craig; Parmar, Yuvrajsinh J; Kronzon, Itzhak

    2017-09-06

    With an increasing number of interventional procedures performed for structural heart disease and cardiac arrhythmias each year, echocardiographic guidance is necessary for safe and efficient results. The purpose of this review article is to overview the principles of intracardiac echocardiography (ICE) and describes the peri-interventional role of ICE in a variety of structural heart disease and electrophysiological interventions. Both transthoracic (TTE) and transesophageal echocardiography have limitations. ICE provides the advantage of imaging from within the heart, providing shorter image distances and higher resolution. ICE may be performed without sedation and avoids esophageal intubation as with transesophageal echocardiography (TEE). Limitations of ICE include the need for additional venous access with possibility of vascular complications, potentially higher costs, and a learning curve for new operators. Data supports the use of ICE in guiding device closure of interatrial shunts, transseptal puncture, and electrophysiologic procedures. This paper reviews the more recent reports that ICE may be used for primary guidance or as a supplement to TEE in patients undergoing left atrial appendage (LAA) closure, interatrial shunt closure, transaortic valve implantation (TAVI), percutaneous mitral valve repair (PMVR), paravalvular leak (PVL) closure, aortic interventions, transcatheter pulmonary valve replacement (tPVR), ventricular septal defect (VSD), and patent ductus arteriosus (PDA) closure. ICE imaging technology will continue to expand and help improve structural heart and electrophysiology interventions.

  15. Accuracy of Self-Reported Physical Activity Levels in Obese Adolescents

    PubMed Central

    Elliott, Sarah A.; Baxter, Kimberley A.; Davies, Peter S. W.; Truby, Helen

    2014-01-01

    Introduction. Self-reported measures of habitual physical activity rely completely on the respondent's ability to provide accurate information on their own physical activity behaviours. Our aim was to investigate if obese adolescents could accurately report their physical activity levels (PAL) using self-reported diaries. Methods. Total energy expenditure (TEE) was measured using doubly labelled water (DLW) and resting energy expenditure (REE) was measured via indirect calorimetry. Activity energy expenditure (AEE) and PAL values were derived from measured TEE and REE. Self-reported, four-day activity diaries were used to calculate daily MET values and averaged to give an estimated PAL value (ePAL). Results. Twenty-two obese adolescents, mean age 13.2 ± 1.8 years, mean BMI 31.3 ± 4.6 kg/m2, completed the study. No significant differences between mean measured and estimated PAL values were observed (1.37 ± 0.13 versus 1.40 ± 0.34, P = 0.74). Bland Altman analysis illustrated a significant relationship (r = −0.76, P < 0.05) between the two methods; thus the bias was not consistent across a range of physical activity levels, with the more inactive overreporting their physical activity. Conclusion. At an individual level, obese adolescents are unlikely to be able to provide an accurate estimation of their own activity. PMID:25247095

  16. False positive computed tomographic angiography for Stanford type A aortic dissection.

    PubMed

    Bandali, Murad F; Hatem, Muhammed A; Appoo, Jehangir J; Hutchison, Stuart J; Wong, Jason K

    2015-12-01

    Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Department bedside ultrasound suggesting an intimal flap in the aorta, CTA was requested to better assess the ascending aorta and was interpreted as consistent with Stanford Type A aortic dissection with thrombosis of the false lumen in the ascending aorta. However, intra-operative imaging (TEE and epi-aortic scanning) did not identify an intimal flap or dissection, and neither did definitive surgical inspection of the aorta. The suspected aortic dissection and thrombosed false lumen were not visualized on repeat CTA two days later. False positive diagnosis of Stanford Type A aortic dissection on CTA can be the result of technical factors, streak artifacts, motion artifacts, and periaortic structures. In this case, non-uniform arterial contrast enhancement secondary to unrecognized biventricular dysfunction resulted in the false positive CTA appearance of an intimal flap and mural thrombus. Intra-operative TEE and epi-aortic scanning were proven correct in excluding aortic dissection by the standard of definitive surgical inspection of the aorta.

  17. Energy Deficit Required for Rapid Weight Loss in Elite Collegiate Wrestlers.

    PubMed

    Kondo, Emi; Sagayama, Hiroyuki; Yamada, Yosuke; Shiose, Keisuke; Osawa, Takuya; Motonaga, Keiko; Ouchi, Shiori; Kamei, Akiko; Nakajima, Kohei; Higaki, Yasuki; Tanaka, Hiroaki; Takahashi, Hideyuki; Okamura, Koji

    2018-04-26

    To determine energy density for rapid weight loss (RWL) of weight-classified sports, eight male elite wrestlers were instructed to lose 6% of body mass (BM) within 53 h. Energy deficit during the RWL was calculated by subtracting total energy expenditure (TEE) determined using the doubly labeled water method (DLW) from energy intake (EI) assessed with diet records. It was also estimated from body composition change estimated with the four-component model (4C) and other conventional methods. BM decreased significantly by 4.7 ± 0.5 kg (6.4 ± 0.5%). Total body water loss was the major component of the BM loss (71.0 ± 7.6%). TEE was 9446 ± 1422 kcal, and EI was 2366 ± 1184 kcal during the RWL of 53-h; therefore, the energy deficit was 7080 ± 1525 kcal. Thus, energy density was 1507 ± 279 kcal/kg ∆BM during the RWL, comparable with values obtained using the 4C, three-component model, dual energy X-ray absorptiometry, and stable isotope dilution. Energy density for RWL of wrestlers is lower than that commonly used (7400 or 7700 kcal/kg ΔBM). Although RWL is not recommended, we propose that commonly practiced extreme energy restriction such as 7400 or 7700 kcal/kg ΔBM during RWL appears to be meaningless.

  18. A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography.

    PubMed

    Chen, Chao; Raghunathan, Shreyas B; Yu, Zili; Shabanimotlagh, Maysam; Chen, Zhao; Chang, Zu-yao; Blaak, Sandra; Prins, Christian; Ponte, Jacco; Noothout, Emile; Vos, Hendrik J; Bosch, Johan G; Verweij, Martin D; de Jong, Nico; Pertijs, Michiel A P

    2016-01-01

    This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal echocardiography (TEE) probe. It consists of an array of 9 ×12 piezoelectric elements mounted on the ASIC via an integration scheme that involves direct electrical connections between a bond-pad array on the ASIC and the transducer elements. The ASIC addresses the critical challenge of reducing cable count, and includes front-end amplifiers with adjustable gains and micro-beamformer circuits that locally process and combine echo signals received by the elements of each 3 ×3 subarray. Thus, an order-of-magnitude reduction in the number of receive channels is achieved. Dedicated circuit techniques are employed to meet the strict space and power constraints of TEE probes. The ASIC has been fabricated in a standard 0.18-μm CMOS process and consumes only 0.44 mW/channel. The prototype has been acoustically characterized in a water tank. The ASIC allows the array to be presteered across ±37° while achieving an overall dynamic range of 77 dB. Both the measured characteristics of the individual transducer elements and the performance of the ASIC are in good agreement with expectations, demonstrating the effectiveness of the proposed techniques.

  19. Does self-perceived sleep reflect sleep estimated via activity monitors in professional rugby league athletes?

    PubMed

    Caia, Johnpaul; Thornton, Heidi R; Kelly, Vincent G; Scott, Tannath J; Halson, Shona L; Cupples, Balin; Driller, Matthew W

    2018-07-01

    This study examined agreement between self-perceived sleep and sleep estimated via activity monitors in professional rugby league athletes. 63 athletes, from three separate teams wore actigraphy monitors for 10.3 ± 3.9 days. During the monitoring period, ratings of perceived sleep quality (on a 1-5 and 1-10 Likert scale), and an estimate of sleep duration were recorded daily. Agreement between sleep estimated via activity monitors and self-perceived sleep was examined using mean bias, Pearson correlation (r) and typical error of the estimate (TEE). 641 nights of sleep were recorded, with a very large, positive correlation observed between sleep duration estimated via activity monitors and subjective sleep duration (r = 0.85), and a TEE of 48 minutes. Mean bias revealed subjective sleep duration overestimated sleep by an average of 19.8 minutes. The relationship between sleep efficiency estimated via activity monitors and self-perceived sleep quality on a 1-5 (r = 0.22) and 1-10 Likert scale (r = 0.28) was limited. The outcomes of this investigation support the use of subjective measures to monitor sleep duration in rugby league athletes when objective means are unavailable. However, practitioners should be aware of the tendency of athletes to overestimate sleep duration.

  20. Resolution of massive left atrial appendage thrombi with rivaroxaban before balloon mitral commissurotomy in severe mitral stenosis: A case report and literature review.

    PubMed

    Li, Yuechun; Lin, Jiafeng; Peng, Chen

    2016-12-01

    Data on nonvitamin K antagonist oral anticoagulant being used for the treatment of LAA thrombi are limited only in nonvalvular atrial fibrillation. There are no data on the antithrombotic efficacy and safety of nonvitamin K antagonist oral anticoagulant in the resolution of left atrial appendage (LAA) thrombi in patients with rheumatic mitral stenosis. A 49-year-old woman with known rheumatic mitral stenosis and atrial fibrillation was referred for percutaneous transvenous mitral commissurotomy because of progressive dyspnea on exertion over a period of 3 months. Transesophageal echocardiography (TEE) demonstrated a large LAA thrombus protruding into left atria cavity before the procedure. Direct factor Xa (FXa) inhibitor rivaroxaban (20 mg/d) was started for the patient. After 3 weeks of rivaroxaban treatment TEE showed a relevantly decreased thrombus size, and a complete thrombus resolution was achieved after 5 weeks of anticoagulant therapy with the FXa inhibitor. To the best of our knowledge, this is the first documented case of large LAA thrombus resolution with nonvitamin K antagonist oral anticoagulant in severe mitral stenosis, and in which percutaneous transvenous mitral commissurotomy was performed subsequently. The report indicated that rivaroxaban could be a therapeutic option for mitral stenosis patients with LAA thrombus. Further study is required before the routine use of rivaroxaban in patients with rheumatic mitral stenosis and atrial fibrillation.